TECHNICAL DATA
RL-XPS BOARD
DESCRIPTION
RL-XPS BOARD closed-cell structure
resists water absorption, enabling it to
retain a high R-value (RSI)** over time –
a necessary property in below-grade
residential foundation applications. It
helps to protect foundation damp
proofing and waterproofing, especially
during backfilling. It also provides a
secondary barrier against groundwater
leakage.
FEATURES:
Closed cell extruded polystyrene foam
Lightweight and easy to handle
Enhances thermal efficiency,
Reducing energy cost.
Durable and sturdy for long lasting
applications.
High thermal resistance TECHNICAL DATA:
Strong compressive strength
Low moisture absorption Thickness:
High compressive strength 1″ - 1.5″
Long term retained R-values 2″ - 3″
Environmentally friendly 4″
High insulation value
Insulation reduce noise transmission Sizes:
sound 3ft x 6ft
8ft x 4ft
FIELD OF APPLICATION:
Residential Insulation
Industrial Structures
Control Sheds
Expansion Joints
Commercial Buildings
Water Tanks
Lost Foam Applications
Floor Raising
Craft projects
ROOFLINE (PVT) LIMITED
54-E, Mohafiz Town Multan Road, Lahore
+92 42 35457688, +92 42 35457689
TECHNICAL DATA
Compressive Strength
ITEM TESTING METHOD UNIT RESULT
Highly Cross-Linked
Cell Structure % Closed Cell
Density*
ASTM-D1622 kg/m3 32 - 35 ± 10%
Thermal Conductivity ASTMC-518 BTU in/ft2 hr°F 0.17
25mm (thickness) KS M 3808-'05 W/mk 0.025
R-Value ASTMC-518 ft2hr°F/BTU in 5.588
25.4mm (thickness) KS M 3808-'05 m2k/W 1.02
Compressive Strength ASTM D1621 kPa 220 - 360
Coefficient of Linear BS4370:
mm/mk 0.07
Thermal Expansion Method 13
GB 8624 B1
Fire Classification * LOI
ASTM C-272 28-29.5
Water Absorption by
Volume ASTM C-272 %by Volume ≥ 0.2
mm 1220 – 2440
Size: Length / Width mm 915 – 1830
Thickness mm 20 ~ 100 ± 5%
Butt/ Ship Lap
Edge Profile
Tongue & Groove
TECHNICAL SERVICES:
A trained ROOFLINE representative is
available to assist in the preparation of
specifications in the field.
Field services, where provided, does not
constitute supervisory responsibility. For
additional information contact local
ROOFLINE representative.
ROOFLINE (PVT) LIMITED
54-E, Mohafiz Town Multan Road, Lahore
+92 42 35457688, +92 42 35457689