CAR&CART30/40 SERIES Automotive Relay 30,40 Amp
FEATURES
·High contact rating 40A
File No.:E75887
·High temperature design
·1 Form A and 1 Form C arrangements
·Quick connect and P.C.Board terminals
·Mounting Tab option
CONTACT RATINGS ORDERING INFORMATION
Contact Arrangement 1A, 1C CAR T 1C P 40 DC12 - S - SH - 680R - D - M - XXXX
Contact Resistance 50mΩ (1A 24VDC) Model
T:Mounting Tab
Contact Material SiIver AIIoy Nil:No Mounting
Tab
Contact Rating(Resistive) NO:30/40A 14VDC
1A=1 Form A
NC:20/30A 14VDC 1C=1 Form C
P:PC Pin
Max. Switching Voltage 75VDC Nil:Quick Connect
Max. Switching Current 40A 40:40A 30:30A
Coil Voltage
Max. Switching Power 560W S:Sealed Type Nil:Dust Cover Type
E:Flux Free Type
Mechanical Life 1×106 operations
SH:Shrouded cover W:Weatherproof cover
Electrical Life 1×105 operations Resistor 680Ω 12V Coil & 2700Ω 24V Coil
D:Diode
M:Metal tab Nil:Plastic tab
CHARACTERISTICS Customer code
Note:
Insulation Resistance Shrouded and weather proof available only in metal tab
100MΩ (at 500VDC)
Pc pins only available with or without plastic tabs.
Dielectric Between coil & contacts 500VAC 1min For more details, please contact us directly.
Strength
Between open contacts 500VAC 1min COIL DATA at 20°C
Operate time (at nomi. volt.) ≤10ms
Nominal Pick-up Drop-out Max. Coil
Release time (at nomi. volt.) ≤10ms Voltage Voltage Allowable
Voltage (Max.) (Min.) Voltage Resistance
Ambient temperature -40°C ~ +85°C VDC VDC VDC VDC Ω±10%
Shock Resistance 6 4.2 0.6 7.8 20
147m/s2
Vibration resistance 10Hz ~ 40Hz 1.27mm DA 12 8.4 1.2 15.6 80
Unit weight Approx. 30g 24 16.8 2.4 31.2 320
Construction Sealed Type, Dust Cover Type, 48 33.6 4.8 62.4 1280
Flux Free Type
Notes:1) The data shown above are initial values.
2) Please find coil temperature curve in the characteristic curved below. COIL
SAFETY APPROVAL RATINGS
Coil Power 1800mW
UL&CUL NO:40A/14VDC, 15A/24VDC
NC:30A/14VDC, 15A/24VDC
This datasheet is for customers' reference. All the specifications are subject to change without notice.
RELAYS & ELECTRONICS INT'L. CORP.
TEL:(516) 328-9292 FAX:(516)326-9125 www.hascorelays.com email:info@hascorelays.com
CAR&CART30/40 SERIES Automotive Relay 30,40 Amp
OUTLINE DIMENSIONS Unit: inch(mm)
Quick Connect Shrouded Metal tab
1.028(26.1)
2-.098(2.5)
.738(18.75)
.949(24.1)
.541(13.75)
Φ.25
2(6.
4)
.354
.452(11.5MAX)
(9)
.047(1.2)
Φ.07(1.8) .031
.189(4.8)
.248(6.3)
2.386(60.6)
(0.8)
.728(18.5)
1.087(27.6) 1.087(27.6)
1.028(26.1)
PC Pin
.089(2.25)
1.244(31.6) 1.244(31.6)
.752(19.1)
.452(11.5)
.949(24.1)
.287(7.3)
.043(1.1) .122(3.1)
.118(3)
.102(2.5) .031
1.028(26.1) .205 5.2 .248(6.3) (0.8)
1.028(26.1)
Plastic tab Weatherproof Metal tab
2-.098(2.5)
.738(18.75)
.541(13.75)
Φ.22(5.6) .63(16)
.354
(9)
.63(16)
.09(2.3)
Φ .4)
.366(9.3)
.2
(6
52
.732(18.6)
.949(24.1)
2.693(67.9)
.449(11.4)
.452(11.5MAX)
.169
.331(8.4).453(11.5)
1.039(26.4)
(4.3)
.181(4.6)
.106(2.7)
.031(0.8)
1.028(26.1) .248(6.3) 1.287(32.7)
1.028(26.1) 1.287(32.7) 1.287(32.7)
.264
(6.7)
Remark:1) In case of no tolerance shown in outline dimension: outline dimension ≤1mm,tolerance should be ±0.2mm; outline dimension
>1mm and ≤5mm,tolerance should be ±0.3mm;outline dimension >5mm, tolerance should be ±0.4mm.
2) The tolerance without indicating for PCB layout is always ±0.1mm.
This datasheet is for customers' reference. All the specifications are subject to change without notice.
RELAYS & ELECTRONICS INT'L. CORP.
TEL:(516) 328-9292 FAX:(516)326-9125 www.hascorelays.com email:info@hascorelays.com
CAR&CART30/40 SERIES Automotive Relay 30,40 Amp
WIRING DIAGRAM AND PC BOARD LAYOUT. Unit: inch(mm)
Wiring Diagram PCB Layout
(Bottom view) (Bottom view)
Quick Connect PC Pin .661
5-.031
5-.248
(6.3)
(0.8) (16.8)
86(+)
86(+)
Diode or
Diode or Resistor 5-Φ.118(3)
Resistor 30 If Used
30 87A 87
87 If Used .705
(17.9)
87A
.705
(17.9)
85(–)
85(–)
(8.4)
.331
(8.4)
.331
.315
(8)
1A 1C .315
8 .661
(16.8)
CHARACTERISTIC CURVES
1.Load limit curve(at 23°C)
Switching voltage (VDC)
(1) This chart takes NO contact, resistive load as example.
(2) The load and electrical endurance tests are made
according to “CONTACT DATA” parameters’ table.
If actual load voltage, current, or operate frequency
is different from “CONTACT DATA” table, please
arrange corresponding tests for confirmation.
Switching current (A)
2.Ambient temperature curve of the electrical endurance test
Ambient temp. curve (one cycle)
Temperature(°C)
(1) The minimum temperature is -40°C.
(2) The maximum temperature is 125°C.
Time(h)
This datasheet is for customers' reference. All the specifications are subject to change without notice.
RELAYS & ELECTRONICS INT'L. CORP.
TEL:(516) 328-9292 FAX:(516)326-9125 www.hascorelays.com email:info@hascorelays.com