0% found this document useful (0 votes)
19 views2 pages

Multimedia

The 3M™ Aura™ Health Care Particulate Respirator and Surgical Mask, 1870+, N95 is FDA cleared for surgical use, fluid resistant, and features an adjustable nose clip and flat-fold design. It is made from various materials including polypropylene and aluminum, and is intended to protect operating room personnel and patients from microorganisms and body fluids. The mask has a shelf life of 5 years and must be used according to the provided User Instructions to ensure safety and compliance with regulations.

Uploaded by

djozicfamily
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
19 views2 pages

Multimedia

The 3M™ Aura™ Health Care Particulate Respirator and Surgical Mask, 1870+, N95 is FDA cleared for surgical use, fluid resistant, and features an adjustable nose clip and flat-fold design. It is made from various materials including polypropylene and aluminum, and is intended to protect operating room personnel and patients from microorganisms and body fluids. The mask has a shelf life of 5 years and must be used according to the provided User Instructions to ensure safety and compliance with regulations.

Uploaded by

djozicfamily
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 2

3M™ Aura™ Health Care

Particulate Respirator and


Surgical Mask, 1870+,
N95
Key Features

FDA cleared for use as a surgical mask
• Fluid Resistant 160 mmHg
• Flammability Rating Class I
• Adjustable nose clip
• 3-Panel, flat-fold style
• Stapled headbands
• Individually packed

Material Composition
• Straps – Polyisoprene Do Not Use For
• Staples - Steel • DO NOT use in industrial settings
• Nose Clip – Aluminum • DO NOT use for gases or vapors (i.e.
• Nose Foam - Polyurethane anesthetic gases such as isoflurane or vapors
• Filter – Polypropylene from sterilants such as glutaraldehyde.)
• Coverweb – Polypropylene • DO NOT use in any manner not indicated in
• Not made with natural rubber latex the User Instructions
• Approximate weight of product: 0.35 oz.
Approvals and Standards
• See the 3M Technical Bulletin - Cellulose
Certification - Filtering Facepiece Respirators for • NIOSH approved N95 respirator
information about which 3M respirators contain • Meets NIOSH 42 CFR 84 N95 requirements
cellulose for a minimum 95% filtration efficiency
against solid and liquid aerosols that do not
Country of Origin Made in the USA, UK, Singapore, contain oil.
and Canada • NIOSH approval number: TC-84A-5726
Use For • FDA cleared for use as a surgical mask
• Intended to be worn by operating room • Health Canada Class I medical device
personnel during surgical procedures to • Bacterial Filtration Efficiency F2101 >99% BFE
helpprotect both the surgical patient and • Assigned Protection Factor (APF 10) per US
the operating room personnel from transfer OSHA and Canada CSA
of microorganisms, body fluids, and
particulatematerial.
• Always follow User Instructions and use in
manners as indicated
Time Use Limitation Acceptable Fit Test Protocols
Respirator may be used until damaged, breathing
becomes difficult or contaminated with blood or Acceptable with this
Fit Test Protocol*
body fluids. Discard after every use when used product?
for surgical procedures. Follow national, state, Saccharin ☒
local, and facility infection control guidance and BitrexTM
policies. ☒
Qualitative
Protocols Irritant

Shelf Life and Storage Smoke
• 5 years from the date of manufacture Isoamyl

• Use By date on box in YYYY-MM-DD format Acetate
• Store respirators in the original packaging, Quantitative Protocols ☒
away from contaminated areas, dust,
sunlight, extreme temperatures, excessive *Refer to OSHA 1910.134
moisture, and damaging chemicals
• Store in temperatures between -4°F
(-20°C) and +86°F (+30°C) and not
exceeding 80% RH
WARNING!
This respirator helps protect against certain
particulate contaminants but does not eliminate
exposure to or the risk of contracting any disease
or infection. Before use, the wearer must read
and understand the User Instructions provided as
a part of the product packaging. Follow all local
regulations. In the U.S., a written respiratory
protection program must be implemented
meeting all the requirements of OSHA 1910.134,
including training, fit testing and medical
evaluation. In Canada, CSA standard Z94.4
requirements must be met and/or requirements
of the applicable jurisdiction, as appropriate.
Misuse may result in sickness or death. For
correct use, consult supervisor and the User
Instructions, or call 3M Health Care in USA at
1-800-228-3957 and in Canada at 1-800-267-
4414.

3M Company
2510 Conway Avenue
St. Paul, MN 55144-1000 3M and Aura are trademarks of 3M. Please recycle. Printed in
U.S.A. Used under license in Canada.
1-800-228-3957
© 3M 2021. All rights reserved.
3M.com/medical

You might also like