GENERAL CATALOGUE 2014
Rev. 01
                        -   REFRIGERATED AIR DRYERS DGO SERIES
                                                    The DGO series has been designed with the aim of combining the
                                                    maximum efficiency with the maximum compactness. Within each model
                                                    the heat exchanger designed, patented and unique on the market, has 3
                                                    distinct stages of the process: the first stage for the exchange
                                                    regeneration, a second stage of thermal mixing of the front of incoming
                                                    air and the last stage of heat exchange and condensate separation.
                                                    Every dryer of series is managed by an electronic system able to provide
                                                    a real-time control of multiple functions simultaneously such as dew
                                                    point, work pressures, discharge times etc. DGO dryers are supplied in
                                                    electronic timed condensate drain directly managed by the electronic
                                                    card.
                                                    On demand for all models is available an intelligent drain.
                                                                                                           Power-
       Model      Refrigerant           Flow-Rate           Connection      Dimension         Weight
                                                                                                           Supply
                                    3
                      TYPE      m /h      l /mi n   s cfm      BSP-F       W x L x H [mm]     kg    lbs     V/ph/f
      DGO20          R134a       20    333   12                1/2"        365 x 455 x 500    23     51    230/1/50
      DGO35          R134a       35    583   20                1/2"        365 x 455 x 500    23     51    230/1/50
      DGO66          R134a       66   1100   39                1/2"        365 x 455 x 500    26     57    230/1/50
      DGO80          R134a       80   1300   47                1/2"        365 x 455 x 500    26     57    230/1/50
      DGO108         R134a       108 1800    64                3/4"        410 x 560 x 550    37     82    230/1/50
      DGO150         R134a       150 2500    88                3/4"        410 x 560 x 550    37     82    230/1/50
      DGO195         R407C       195 3250    115               3/4"        410 x 560 x 550    40     88    230/1/50
      DGO270         R407C       270 4500    159                1"        350 x 540 x 1010    47     104   230/1/50
      DGO365         R407C       365 6083    215              1.1/2"       440 x 600 x 980    90     198   230/1/50
      DGO480         R407C       480 8000    283              1.1/2"       440 x 600 x 980    95     209   230/1/50
      DGO660         R407C       660 11000 389                  2"        590 x 910 x 1220    130    287   230/1/50
      DGO780S        R407C       780 13000 459                  2"        590 x 910 x 1220    150    331   230/1/50
      DGO780         R407C       780 13000 459                  2"        590 x 910 x 1220    170    375   400/3/50
      DGO1000        R407C      1000 16667 589                  2"        590 x 910 x 1220    173    382   400/3/50
      DGO1300        R407C      1300 21667 765                  2"        590 x 910 x 1220    175    386   400/3/50
      DGO1700        R407C      1700 28333 1000                 3"        658 x 1379 x 1465   300    661   400/3/50
      DGO2200        R407C      2200 36667 1295                 3"        658 x 1379 x 1465   300    661   400/3/50
      DGO2700        R407C      2700 45000 1589               DN100       658 x 1379 x 1465   330    728   400/3/50
      DGO3600        R407C      3600 60000 2119               DN125      1510 x 1500 x 1600   420    926   400/3/50
      DGO4200        R407C      4200 70000 2472               DN125      1510 x 1500 x 1600   520   1146   400/3/50
      DGO5300        R407C      5300 88333 3119               DN150      1510 x 1500 x 1600   620   1367   400/3/50
      DGO6500        R407C      6500 108300 3825              DN150      1510 x 1500 x 1600   720   1587   400/3/50
      DGO7200        R407C      7200 120000 4237              DN150      1510 x 1500 x 1600   750   1654   400/3/50
DATA REFER TO THE FOLLOWING NOMINAL CONDITIONS:
       AMBIENT TEMPERATURE: 25°C
       INLET AIR PRESSURE: 7 barg
       INLET AIR TEMPERATURE: 35°C
       DEW POINT: 3°C (-22 C° ATMOSPHERIC PRESSURE DEW POINT)
MAX. WORKING CONDITION:
      AMBIENT TEMPERATURE 45°C
      INLET AIR TEMPERATURE 55°C
                            REFRIGERATED AIR DRYERS DSI SERIES
                                                         The series of dryers DSI is the result of research of
                                                         the extreme compactness and value for money. The
                                                         electronic controllers by which every model is
                                                         supplied, provide full control and management of
                                                         performances of dryers.
                                                         Robustness, simplicity and proper sizing of each
                                                         component make the DSI series ideal for achieve
                                                         outstanding    performance     combined     with
                                                         exceptional economicity.
             Compressor                                                                               Power-
   Model                          Flow-Rate         Connection     Dimension           Weight
             Combination                                                                              Supply
                 kW / Hp       l/min   m3/h scfm       BSP        W x L x H [mm]      kg      lbs     V/ph/F
   DSI36         4 / 5,5        600    36     21       1/2"      365 x 455 x 500      23      51     230/1/50
   DSI54        5,5 / 7,5       900    54     32       1/2"      365 x 455 x 500      23      51     230/1/50
   DSI84         9 / 12        1400    84     49       1/2"      365 x 455 x 500      26      57     230/1/50
   DSI108       11 / 15        1800    108    64       1/2"      365 x 455 x 500      26      57     230/1/50
   DSI144       15 / 20        2400    144    84       3/4"      410 x 560 x 550      37      82     230/1/50
   DSI180       22 / 30        3000    180    106      3/4"      410 x 560 x 550      37      82     230/1/50
   DSI228       30 / 40        3800    228    134      3/4"      410 x 560 x 550      40      88     230/1/50
   DSI318       37 / 50        5300    318    186       1"       350 x 540 x 1010     43      95     230/1/50
DATA REFER TO THE FOLLOWING NOMINAL CONDITIONS:
       AMBIENT TEMPERATURE: 25°C
       INLET AIR PRESSURE: 7 barg
       INLET AIR TEMPERATURE: 35°C
       DEW POINT: 7°C
MAX. WORKING CONDITION:
      AMBIENT TEMPERATURE: 45°C
      INLET AIR TEMPERATURE: 55°C
                HIGH INLET TEMPERATURE AIR DRYERS DTG SERIES
                                                            By an air suction system for condenser and
                                                            aftercooler through a unique and powerful
                                                            fan, the models of the DTG series, unique
                                                            on the market in their conception, they
                                                            reach maximum efficiency in the smallest
                                                            space.
                                                            On all models there is a timed drain
                                                            electronically controlled by the electronic
                                                            board.
Model       Refrigerant           Flow-rate          Connections    Dimensions         Weight       Power-supply
                             3
              TYPE         m /h     l/min     scfm      BSP-F            mm           kg     lb            V/ph/f
DTG36         R134a         36      600        21       1/2"       430 x 530 x 570    40    88            230/1/50
DTG66         R134a         66      1100       39       1/2"       430 x 530 x 570    46    95            230/1/50
DTG99         R134a         99      1650       58       3/4"       460 x 580 x 640    50    110           230/1/50
DTG141        R134a        141      2350       83       3/4"       460 x 580 x 640    54    119           230/1/50
DTG270        R407C        270      4500      159        1"        490 x 540 x 650    58    128           230/1/50
  DATA REFER TO THE FOLLOWING NOMINAL CONDITIONS:
            AMBIENT TEMPERATURE: 35°C
            INLET AIR PRESSURE: 7 barg
            INLET AIR TEMPERATURE: 80°C
            DEW POINT: 3°C                                                                                  H
  MAX. WORKING CONDITION:
        AMBIENT TEMPERATURE: 45°C
        INLET AIR TEMPERATURE: 90°C
                                                                        W
                     HEATLESS ADSORPTION DRYER MD SERIES
                                                          MD series is particularly suitable for various
                                                          applications, such for example chemical
                                                          applications or pharmaceutical applications
                                                          and for laboratories that need a high quality
                                                          compressed air.
                                                Max                                               Power-
    Model                   Flow-rate                    Weight             Dimensions
                                              pressure                                            supply
                                3
                    l/min     m /h      cfm     bar        kg      H [mm]     W [mm]     D [mm]    V/ph/f
        HSI.00006   100        6        3,5      10        5,5      435        217         86     230/1/50
        HSI.00012   200        12        7       10        7,5      520        217         86     230/1/50
        HSI.00024   400        24       14       10        14       520        217        166     230/1/50
DATA REFER TO THE FOLLOWING NOMINAL CONDITIONS:
         AMBIENT TEMPERATURE        25°C
         WORKING PRESSURE           8BAR
         INLET AIR TEMPERATURE      35°C
         DEW POINT                  -40°C
                           COMPRESSED AIR LINE FILTERS FGO SERIES
                                                     The series of aluminum filters FGO ensures filtration of
                                                     a wide range of flow rates; also the filter elements are
                                                     of the type of antidust (filter and cartridge type P),
                                                     disoiling (filter and cartridge type M and H) and
                                                     activated carbon (filter and cartridge type C) able to
                                                     satisfy the most varied requirements of filtrations and
                                                     applications of circuits with compressed air.
                  Model       Connections              Flow-rate           Dimensions [mm]        Element
                                                 3
                                    BSP-F       m /h     l/min     scfm    WIDTH(A)   HEIGHT(B)    MODEL
                FGO00034             1/2"        34       570       20        95        210        0034E
                FGO00077             1/2"        77      1280       45        95        210        0077E
                FGO00119             3/4"        119     1980       70        95        270        0119E
                FGO00170             3/4"        170     2830       100       95        270        0170E
                FGO00212              1"         212     3540       125      125        300        0212E
                FGO00306              1"         306     5100       180      125        300        0306E
                FGO00451            1.1/2"       451     7510       265      125        380        0451E
                FGO00629            1.1/2"       629     10480      370      125        380        0629E
                FGO00875              2"         875     14590      515      170        500        0875E
                FGO01267              2"        1267     21110      745      170        680        1267E
                FGO01800            2.1/2"      1800     30000     1060      200        870        1800E
                FGO02176              3"        2176     36270     1280      200        870        2176E
                FGO02805              3"        2805     46750     1650      200        980        2805E
Aluminium filters for compressed air.
Max working condition:
   Inlet temperature = 60 - 100°C
   Inlet air pressure = 16 barg
Filters are equipped with:
     Manual drain on all models F0020..F1650
P = 3 MICRON
M = 1 MICRON
H = 0,01 MICRON
                                                           FILTER MODEL FGO0034P FGO0034M FGO0034H FGO0034C
C = ACTIVATED CARBON                                       ELEMENT MODEL 0034EP 0034EM 0034EH 0034EC
                     COMPRESSED AIR LINE STEEL FILTERS FGO SERIES
                                                    The series of carbon steel filters FGO ensures filtration
                                                    of a wide range of flow rates; also the filter elements
                                                    are of the type of antidust (filter and cartridge type P),
                                                    disoiling (filter and cartridge type M and H) and
                                                    activated carbon (filter and cartridge type C) able to
                                                    satisfy the most varied requirements of filtrations and
                                                    applications of circuits with compressed air.
                 Model         Connections            Flow-rate             Dimensions [mm]         Element
                                               3
                                     DN      m /h        l/min     scfm    WIDTH(A)    HEIGHT(B)     MODEL
               FGO05600              100     5600      93300       3300       520        1170        2805E
               FGO08500              150     8500      141670      5000       680        1250        2805E
               FGO12000              200     12000     200000      7060       780        1330        2805E
               FGO20000              250     20000     333300     11760       900        1532        2805E
               FGO30000              300     30000     500000     17640       900        1532        2805E
Carbon steel filters for compressed air.
Max working condition:
   Inlet temperature = 60 - 100°C
   Inlet air pressure = 16 barg
P = 3 MICRON
M = 1 MICRON
H = 0,01 MICRON
C = ACTIVATED CARBON
                WATER SEPARATOR SGO SERIES
 Model     Connections           Flow-rate                  Dimensions [mm]
                           3
              BSP-F      m /h      l/min     scfm   WIDTH(A)    HEIGHT(B)      C
SGO00078       1/2"        78      1300    45         95          220         197
SGO00168       3/4"       170      2800   100         95          280         257
SGO00306        1"        306      5100   180         125         315         285
SGO00630      1.1/2"      630     10500   370         125         397         367
SGO01266        2"       1266     21100   745         170         700         478
SGO02400      DN100      2400     40000   1412
SGO03000      DN125      3000     50000   1765
SGO06500      DN150      6500     108333 3824,2
SGO12000      DN200      12000    200000 7060
                                              ACCESSORIES
Differential pressure gauge
                                                    Max
Model                    Combination                           Max temperature
                                                  pressure
                                                     bar             °C
             Available on all filters model
PDG.00000                                            16              90
             FGO00034 .. FGO02805
Auto-drain
                                                   Max
Model                   Combination                             Connections
                                                 pressure
                                                    bar
            Available on all filters model
TFL.00000                                           16             M14
            FGO00034 .. FGO02805
Timed drain
Model                    Max pressure            Connections
                              bar                   BSP-F
TTM.00000                      16                   3/8"
Thermodinamical drain
Model                   Max pressure            Connections
                              bar                  BSP-F
TTH.00000                     16                   3/8"
WATER/OIL SEPARATORS OWS SERIES PRICES 2014
             Model            Flow-rate
                        3
                       m /h     l/min     scfm
             OWS1      170     2830       100
             OWS2      510     8500       300
             OWS3      1275    21250      750
             OWS4      2550    42500      1500
            OWS KIT1   170     2830       100
            OWS KIT2   510     8500       300
            OWS KIT3   1275    21250      750
            OWS KIT4   2550    42500      1500