This instruction manual provides guidelines for adjusting and installing a photocell light fitting, including testing procedures and safety precautions. It emphasizes the importance of proper positioning to avoid false triggering and outlines the technical specifications of the product. Additionally, it includes care instructions and recycling information for waste electrical products.

Uploaded by

Mali
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
7 views2 pages

Non-Twilight Detector

This instruction manual provides guidelines for adjusting and installing a photocell light fitting, including testing procedures and safety precautions. It emphasizes the importance of proper positioning to avoid false triggering and outlines the technical specifications of the product. Additionally, it includes care instructions and recycling information for waste electrical products.

Uploaded by

Mali
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 2

Photocell Adjustment Instruction manual

• Slide the LUX knob to position(moon) and switch on the power. Photocell

TWILIGHT DETECTOR
• When you test in daytime. You should cover a black opaque cloth on the product.
• When the cloth mantles the detection window of the photocell, the ambient light
of the photocell is less than10 LUX, the lamp will be on.
• When you take off this cloth, the lamp will be off automatically. 90979, 90980
• When you slide the LUX knob to position sun, the lamp could be on in the
ambient light less than 10LUX.

Note:
• In front of the photocell, it should be no obstruction affecting to accept natural light;
Wall mounting hole
• In front of the photocell, it should be no swaying object.
• Don’t install the photocell under the light or in the place where the light will be irradiated to the photocell.
• When lamp is on and the intensity of another light source reaches the light off LUX value, and this light
lasts for less than one minute, the lamp will switch off.

Technical data
Supply Voltage: 220-240V~
Power Frequency: 50Hz
Rated Current: 15A
Ambient Light:<5-300Lux (adjustable)
Working Temperature: -20~+45ºC
Working Humidity: <93%RH
909 909
80 79
Conformity with all relevant UKCA Directive requirements.

Conformity with all relevant EC Directive requirements.

The power supply is Double Insulated and does not require connection to an Earth circuit.

Waste electrical products should not be disposed of with household waste. Please recycle where facilities
exist. Check with your Local Authority or local store for recycling advice.

IP44
This product is rated at IP44.

Care and Safety


We recommend cleaning with a soft dry cloth. Do not use solvents or abrasive cleaners as these could damage the finish.
For your safety, always switch off the power supply before changing lightbulbs, or cleaning.

V2 12/07/2022
UK Manufacturer: BH17 7BY
EU Manufacturer: Brilliant AG,
Brilliantstrasse 1, D-27442 Gnarrenburg www.saxbylighting.com
Thank you for purchasing this light fitting. Please read the instructions carefully before use to ensure safe and satisfactory Installation
operation of this product. Please retain these instructions for future reference.
Existing fittings must be completely removed before installation of a new product. Before removing the existing fitting, carefully
note the position of each set of wires.

Warning Note that the switch is turned off before installation.


Ensure that the screws and cable entry points are sealed to maintain the IP rating of the product.
This product is double insulated and does
After deciding the layout of the light fittings ensure that the cables are long enough to connect to desired positions.
not require connection to an Earth circuit.
• Undo one screw at the bottom of the product to separate the rear panel from product. Keep screw in safe place for
Please read these instructions carefully before commencing any work. refitting later.
This unit must be fitted by a competent and qualified electrician. • Connect the wire with the product as per the connection wire diagram.
Install in accordance with the IEE Wiring regulations and current Building Regulations.
• According to the correct installation place, install the product with the enclosed inflated screws.
Check the pack and make sure you have all the parts listed. Make sure the rear panel is correctly oriented.
To prevent electrocution switch off at the mains supply before installing or maintaining this fitting. Ensure other persons cannot
• Install back the cover. Switch on the power, and then test it
restore the electrical supply without your knowledge.
If you are in any doubt, please consult a qualified electrician. • Wire as detailed wiring diagram.
If replacing an existing fitting, make a careful note of the connections.
This unit should be connected to a fused circuit.
Waste electrical products should not be disposed of with household waste. Please recycle where facilities exist. Check with
your local authority or retailer for recycling advice.

Layout
Avoid positioning near to trees or shrubs which may cause false triggering during inclement weather.
Avoid pointing at or positioning close to heat sources such as flues or heat extraction units, which may cause false triggering.
Avoid pointing at bright lights as unit will not function when you set Lux control level to dark.
Avoid locating near electromagnetic fields.
The mains supply cable must have a minimum cross section area of 1.0mm2. Wiring
Cables must be protected using suitable conduit or plastic trunking.
This product is double insulated and must not be earthed. If there are any incoming earth cables, they must be joined together
and well insulated with good quality insulation tape. This is to ensure earth continuity throughout your property.
Having correctly identified the wiring from your existing light fitting and connect to the connection block inside the product in
the following way:
Photocell
Front Back

IN OUT
AC~ Load

L N N A

LOAD~ AC/IN~
Wall mounting hole
Check that...
You have correctly identified the wires No loose strands have been left out of the connection block
The connections are tight The cable clamp is fitted over the wires.