Sunman Catalogue 3.1
Sunman Catalogue 3.1
Manufacturing Excellence:
We specialize in the production of high-quality duct works, grilles, kitchen
hoods, and a wide array of ACMV systems and accessories. Utilizing state-of-
the-art technology, including laser cutting and welding services, we ensure
precision and durability in every product we create.
Customized Solutions:
Our expertise extends to delivering tailor-made solutions for diverse
sectors. Whether it’s marine vessels and shipping or general building and
construction, we understand the unique requirements of each project and
provide customized ducting and ventilation systems that meet stringent
quality standards.
Comprehensive Services:
From initial design to final installation, we offer integrated services that
cover every aspect of your HVAC needs. Our team of skilled professionals is
committed to ensuring efficient, timely, and high-quality service delivery.
CONTENTS
GRILLES
DIFFUSERS
CEILING DIFFUSER 17
ROUND DIFFUSER 24
SWIRL DIFFUSER 28
JET DIFFUSER 31
LINEAR DIFFUSER 36
LIGHT TROFFER 44
LOUVRES
FIXED LOUVRE 47
EXTERNAL AIR LOUVRE 51
NOZZLES
DAMPERS
GRILL
APPLICATION
Our Bar Grilles are mainly used for cooling, heating and
ventilation application. The design enables the manipulating
the airflow orientation and thus creating the desired flow
profile.
FEATURES
CONSTRUCTION
MATERIAL
Finished (FF160/23/C3)
GRILLES 02
LINEAR BAR GRILLE
MOUNTING DETAILS
TYPE “SM”
EXPOSED SCREW MOUNTING
GRILLES 03
LINEAR BAR GRILLE
DIMENSIONAL DETAILS
0° DEFLECTION 0° DEFLECTION
GRILLES 04
LINEAR BAR GRILLE
PERFORMANCE DATA
AIRFLOW (CMH) 252 288 324 360 540 720 900 1080 1260 1440 1620 1800 2160 2520 2880 3240 3600 3960 4320 4680 5040 5400
BG SIZE FLOW
70 80 90 100 150 200 250 300 350 400 450 500 600 700 800 900 1000 1100 1200 1300 1400 1500
(mm) RATE (L/s)
S.P. (Pa) 11 15 19 23 52 93 145 208 283 370 467 576
300 x 62 NR 10 14 17 21 33 42 49 54 59 63 67 70
Throw (m) 9 11 12 13 19 25 30 35 40 45 50 54
S.P. (Pa) 5 6 7 16 29 46 65 89 116 147 181 260 354
350 x 95 NR - - 12 24 33 40 45 50 54 58 61 67 72
Throw (m) 8 9 10 15 19 23 27 31 35 39 42 49 56
S.P. (Pa) 3 7 12 19 28 38 49 62 77 110 150 196 247
400 x 128 NR - 18 26 33 39 44 48 51 55 60 65 69 73
Throw (m) 7 12 15 19 22 25 28 31 34 40 45 50 56
S.P. (Pa) 3 5 8 11 15 20 25 31 44 60 78 99 122
500 x 162 NR 14 21 27 32 37 41 44 48 53 58 62 66 69
Throw (m) 8 11 14 17 19 22 24 26 31 35 39 43 47
S.P. (Pa) 1 2 4 5 7 9 12 15 21 29 38 48 59 71
600 x 195 NR 11 18 24 28 32 35 39 42 48 52 56 60 64 67
Throw (m) 5 8 11 13 15 17 19 21 24 28 31 35 38 41
S.P. (Pa) 1 2 3 4 5 6 8 11 16 20 26 32 38 46 53
700 x 228 NR 16 21 26 29 33 36 38 43 48 52 55 59 62 65 67
Throw (m) 5 8 10 11 13 15 16 20 22 25 28 31 34 36 39
S.P. (Pa) 1 1 1 2 3 3 4 6 8 10 13 16 20 23 27 32 37
850 x 262 NR 13 19 23 27 30 33 36 40 45 48 51 54 57 59 62 65 67
Throw (m) 2 4 6 8 10 11 12 15 17 20 22 24 26 29 31 33 35
S.P. (Pa) 1 1 1 1 2 2 3 5 6 8 9 11 13 16 18 21
1000 x 295 NR 16 21 25 28 31 34 39 43 47 50 53 55 58 60 62 64
Throw (m) 2 4 5 7 8 9 11 14 15 17 19 21 23 25 26 28
S.P. (Pa) - 1 1 1 1 1 2 3 4 5 6 7 8 10 11 13
1150 x 328 NR 14 19 23 27 30 33 38 42 45 49 51 54 56 58 60 62
Throw (m) - 2 3 4 6 7 9 11 12 14 15 17 18 20 21 23
LEGEND
BG - Bar Grille
TEST PERFORMANCE
Units of the grilles have been tested at an independent N.A.T.A. accredited test laboratory in Australia. Test reports
can be provided on request. Throw and Noise Rating (NR) found in the performance data of this catalogue is based on
distance measured from the diffuser to the furthest point where the velocity is 0.25m/s and room absorption of 10 dB
in accordance to the recommendations of the Air Diffusion Council.
GRILLES 05
SINGLE DEFLECTION
EXTRUDED ALUMINIUM RETURN AIR REGISTER
SINGLE DEFLECTION
GRILL
APPLICATION
Equipped with both horizontal or/and vertical deflection
blades, the Single Deflection diffusers (LA-SD) have
adjustable flow pattern and throw length for supply air
applications.
FEATURES
CONSTRUCTION
MATERIAL
Finished (FF160/23/C3)
GRILLES 07
SINGLE DEFLECTION
DIMENSIONAL DETAILS
GRILLES 08
SINGLE DEFLECTION
PERFORMANCE DATA
AIR-
(CMH) 360 540 720 900 1080 1260 1440 1620 1800 2160 2520 2880 3240 3600 3960 4320 4680 5040 5400 5760 6480 7200
FLOW
FLOW
BG SIZE
RATE 100 150 200 250 300 350 400 450 500 600 700 800 900 1000 1100 1200 1300 1400 1500 1600 1800 2000
(mm)
(L/s)
S.P. (Pa) 2 5 9 15 23 31 42 54 68 100 140 186 240 301 370
240 x NR - 11 19 26 31 36 40 43 46 51 56 60 63 66 69
240
Throw (m) 6 10 13 17 20 23 27 30 33 39 44 50 55 60 65
S.P. (Pa) 1 2 3 4 6 8 11 13 20 28 37 47 59 73 88 104
350 x NR - 12 19 24 28 32 36 39 44 49 53 56 59 62 65 67
350
Throw (m) 6 9 11 13 16 18 20 22 27 31 35 39 42 46 50 53
S.P. (Pa) 1 1 2 3 3 4 6 9 11 15 18 22 27 32 38 44
460 x NR 13 19 23 27 31 34 39 43 47 51 54 57 59 62 64 66
460
Throw (m) 7 9 11 13 14 16 19 22 25 28 31 34 37 40 43 45
S.P. (Pa) 1 1 1 1 2 2 3 4 5 7 8 10 12 14 16 19
580 x
NR 14 19 23 26 29 35 39 43 46 49 52 55 57 59 62 64
580
Throw (m) 6 7 9 10 11 14 16 19 21 23 26 28 30 32 35 37
S.P. (Pa) - - - 1 1 1 1 2 3 3 4 5 6 7 8 9 11
690 x
NR 11 16 19 23 26 31 36 40 43 46 49 51 54 56 59 61 65
690
Throw (m) 4 5 6 7 8 10 12 14 16 18 20 22 24 26 27 29 33
S.P. (Pa) - - - - - 1 1 1 1 2 2 3 3 3 4 5 6
830 x NR 12 16 20 23 28 32 36 40 43 45 48 51 53 55 58 61 65
830
Throw (m) 3 4 5 6 7 9 10 12 13 15 16 18 19 21 22 25 28
S.P. (Pa) - - - - - - 1 1 1 1 1 2 2 2 3 3
960 x NR 14 17 20 25 30 34 37 40 43 46 48 51 53 55 59 62
960
Throw (m) 2 3 4 5 6 8 9 10 11 13 14 15 16 18 20 22
S.P. (Pa) - - - - - - - - 1 1 1 1 1 1 2 2
1100 x NR 12 15 18 23 28 32 35 38 41 43 46 48 51 53 56 60
1100
Throw (m) 1 2 2 3 4 5 7 8 9 10 11 12 13 14 16 18
S.P. (Pa) - - - - - - - - - - 1 1 1 1 1
1240 x NR 13 17 22 26 30 33 36 39 41 44 46 48 51 54 58
1240
Throw (m) 1 1 2 3 4 5 6 7 7 8 9 10 11 12 14
LEGEND
SDG - Single Deflection Grille
TEST PERFORMANCE
Units of the grilles have been tested at an independent N.A.T.A. accredited test laboratory in Australia. Test reports
can be provided on request. Throw and Noise Rating (NR) found in the performance data of this catalogue is based on
distance measured from the diffuser to the furthest point where the velocity is 0.25m/s and room absorption of 10 dB
in accordance to the recommendations of the Air Diffusion Council.
GRILLES 09
DOUBLE DEFLECTION
EXTRUDED ALUMINIUM RETURN AIR REGISTER
DOUBLE DEFLECTION
GRILL
APPLICATION
Equipped with both horizontal or/and vertical deflection
blades, the Double Deflection diffusers (LA-DD) have
adjustable flow pattern and throw length to provide the
required air diffusion pattern.
FEATURES
CONSTRUCTION
MATERIAL
Finished (FF160/23/C3)
GRILLES 11
DOUBLE DEFLECTION
DIMENSIONAL DETAILS
APPLICATION GUIDELINES
0° DEFLECTION
0° SPREAD ANGLE THE TOTAL SPREAD OF AIR IS
ONE THIRD OF THE FLOW
22 1/2° DEFLECTION
AT 22 1/2’ SPREAD ANGLE TOTAL SPREAD IS
AROUND HALF THE THROW
45° DEFLECTION
AT 45° SPREAD ANGLE THE TOTAL SPREAD IS AROUND
ONE AND ONE HALF TIMES THE TOTAL THROW.
GRILLES 12
DOUBLE DEFLECTION
PERFORMANCE DATA
AIRFLOW (CMH) 72 90 108 144 180 216 252 288 324 360 540 720 900 1080 1440 1800 2160 2520 2880 3240 3600 5400
BG SIZE FLOW RATE
20 25 30 40 50 60 70 80 90 100 150 200 250 300 400 500 600 700 800 900 1000 1500
(mm) (L/s)
S.P. (Pa) 16 18 21 25 30 34 38 42 49 49 66 81 95 108 133
150 x 150 NR - - - - - - 12 15 19 21 32 40 46 50 59
Throw (m) - 1 2 3 4 5 6 7 8 8 11 12 14 15 17
S.P. (Pa) 17 20 23 25 28 30 33 43 53 63 71 88 103
200 x 200 NR - - - - - 12 14 25 33 39 43 52 58
Throw (m) 2 3 4 5 5 6 6 9 10 12 13 14 16
S.P. (Pa) 14 16 18 20 22 24 32 39 46 52 64 75 85 95 105
250 x 250 NR - - - - - - 20 27 33 38 46 52 58 62 66
Throw (m) 2 2 3 4 4 5 7 9 10 11 13 14 15 16 17
S.P. (Pa) 16 17 18 24 30 35 40 49 58 66 73 81
300 x 300 NR - - - 15 23 29 33 41 48 53 58 62
Throw (m) 3 3 4 6 7 9 10 11 13 14 14 15
S.P. (Pa) 11 12 16 20 23 26 33 38 43 49 53 58 63
400 x 400 NR - - - 16 22 26 34 40 46 50 54 58 61
Throw (m) 1 2 4 5 6 6 9 10 11 12 13 13 14
S.P. (Pa) 13 14 16 17 23 28 33 37 46 53 61 68 75 81 88
400 x 250 NR - - - - 14 21 27 32 40 46 52 56 60 64 67
Throw (m) 2 2 3 3 6 7 8 9 11 12 13 14 15 15 16
S.P. (Pa) 10 11 15 18 21 24 30 35 40 45 49 53 58 77
600 x 300 NR - - - 14 20 25 33 39 44 49 53 56 59 72
Throw (m) 1 2 3 5 6 7 8 10 11 11 12 13 13 15
S.P. (Pa) 9 11 13 15 18 21 24 27 30 33 35 47
600 x 600 NR - - 12 17 24 30 35 40 44 47 50 63
Throw (m) 1 2 3 4 6 7 8 8 9 10 10 12
S.P. (Pa) 7 8 9 11 13 16 18 20 22 24 25 34
750 x 750 NR - - - 11 19 25 29 34 38 42 45 57
Throw (m) - - 1 2 4 5 6 6 7 8 8 10
S.P. (Pa) 8 10 13 15 17 21 24 28 31 34 37 40 53
1200 x 250 NR - - - 14 19 26 32 38 42 46 50 53 65
Throw (m) - 2 3 4 5 6 8 8 9 10 11 11 13
S.P. (Pa) 5 7 8 9 11 13 15 17 18 20 21 29
1200 x 600 NR - - - - 16 22 26 31 35 38 41 54
Throw (m) - - - 1 3 4 5 5 6 7 7 9
LEGEND
DDG - Double Deflection Grille Neck Dimensions (mm)
TEST PERFORMANCE
Our Double Deflection Grilles have been tested at an independent N.A.T.A. accredited test
laboratory in Australia. Test reports can be provided on request. Throw and Noise Rating (NR)
found in the performance data of this catalogue is based on distance measured from the diffuser
to the furthest point where the velocity is 0.25m/s and room absorption of 10 dB in accordance to
the recommendations of the Air Diffusion Council.
GRILLES 13
RETURN EGG CRATE
EXTRUDED ALUMINIUM GRILLE
RETURN EGG CRATE
GRILL
APPLICATION
To be used in facilities that has low noise requirements.
Our Return Egg Crate Grille is designed for return and
exhaust application.
FEATURES
CONSTRUCTION
• Grid size : 12 x 12 x 12 mm
MATERIAL
Finished (FF160/23/C3)
GRILLES 15
RETURN EGG CRATE
MOUNTING DETAILS
TYPE “LT”
LAY ON CEILING TEE
DIMENSIONAL DETAILS
GRILLES 16
CEILING DIFFUSER
EXTRUDED ALUMINIUM DIFFUSER
APPLICATION
With wide range of flow deflection designs, Ceiling
Diffusers are capable of providing excellent air
distribution (horizontal/ angled/vertical throw) for a wide
range of operating conditions. By arranging blade vanes
in pre-determine orientation, ceiling diffuser is able to
create multidirectional air flow from a single outlet (1-4
different flow directions).
DIFFUSERS 18
CEILING DIFFUSER
DIFFUSER
CONSTRUCTION
MATERIAL
Finished (FF160/23/C3)
DIFFUSERS 19
CEILING DIFFUSER
TECHNICAL PERFORMANCE
TECHNICAL PERFORMANCE
DIFFUSERS 20
CEILING DIFFUSER
MOUNTING DETAILS
TYPE “LT”
LAY ON CEILING TEE
TYPE “SM”
FLUSH FRAME SURFACE MOUNTED
(CONCEALED CEILING)
DIFFUSERS 21
CEILING DIFFUSER
DIMENSIONAL DETAILS
CEILING DIFFUSER
DIFFUSERS 22
CEILING DIFFUSER
PERFORMANCE DATA
AIRFLOW (CMH) 216 252 288 324 360 540 720 900 1080 1440 1800 2160 2520 2880 3240 3600 5400
LEGEND
CD - CEILING DIFFUSERS FACE DIMENSIONS (MM)
TEST PERFORMANCE
Units of the diffusers have been tested at an independent N.A.T.A. accredited test laboratory in Australia. Test reports
can be provided on request. Throw and Noise Rating (NR) found in the performance data of this catalogue is based on
distance measured from the diffuser to the furthest point where the velocity is 0.25m/s and room absorption of 10 dB
in accordance to the recommendations of the Air Diffusion Council.
DIFFUSERS 23
ROUND DIFFUSER
SUPERFLOW ROUND DIFFUSER
ROUND DIFFUSER
DIFFUSER
APPLICATION
The Round Diffuser has a versatile design to provide a
wide range of flow, ceiling height and supply temperature.
Due to its design, the Round Diffuser is suitable for use in
wide variety of buildings and applications. The multicore
design is mainly for high flow requirements and the single
plate/perforated core is mainly suited for high-end interior
designs, albeit lower flow.
CONSTRUCTION
• Available in multiple/single core configurations
MATERIAL
Finished (FF160/23/C3)
DIFFUSERS 25
ROUND DIFFUSER
DIMENSIONAL DETAILS
H 65 65 65 65 65 65 65 65
ROUND DIFFUSER
DIMENSIONAL DETAILS
DIFFUSERS 26
ROUND DIFFUSER
TECHNICAL PERFORMANCE
supply performance.
Unit Volume Flowrate, m³/hr 250 400 500 800 1000 1400 1600 2000 2500
Neck Area (Eff.
Order Size, inch
Area) m²
Unit Volume Flowrate, l/s 70 112 140 224 280 392 448 560 700
DIFFUSERS 27
SWIRL DIFFUSER
SWIRL DIFFUSER
DIFFUSER
APPLICATION
Suitable to operate with VAV system, the Swirl Diffuser can
operate over a wide range of varying airflow without effects
of dumping. Mainly used in areas with high heat loading
and high air change requirements, the Swirl Diffuser can
also be used for return and exhaust applications.
CONSTRUCTION
• 2’ x 2’
• 600 x 600 mm
configurations available
MATERIAL
DIFFUSERS 29
SWIRL DIFFUSER
DIMENSIONAL DETAILS
DIMENSIONS
LEGEND
DIFFUSERS 30
SWIRL DIFFUSER
TECHNICAL PERFORMANCE
Inlet Dia (mm) Supply Neck Velocity, m/s 2.0 2.5 3.0 3.5 4.0 4.5 5.0 6.0
Volume Flowrate, m³/hr 226 283 339 395 452 509 565 679
Face Velocity, m/s 1.1 1.4 1.7 2.0 2.2 2.5 2.8 3.4
200 Throw Distance-1. (0.5 m/s), m 0.53 0.70 0.87 1.0 1.2 1.4 1.5 1.9
Throw Distance-2. (0.5 m/s), m 0.42 0.56 0.69 0.8 0.96 1.1 1.2 1.5
Total Pressure Loss, Pa <10 <10 <10 <10 11 15.1 19.1 26.0
Volume Flowrate, m³/hr 353 442 530 619 707 795 884 1,060
Face Velocity, m/s 1.8 2.2 2.6 3.1 3.5 3.9 4.4 5.3
250 Throw Distance-1. (0.5 m/s), m 0.63 1.2 1.44 1.71 1.94 2.18 2.45 2.93
Throw Distance-2. (0.5 m/s), m 0.51 0.96 1.15 1.37 1.55 1.74 1.96 2.34
Total Pressure Loss, Pa <10 11 16.6 22.8 26.9 31.5 40.4 55.87
Volume Flowrate, m³/hr 509 636 763 891 1,018 1,145 1,272 1,527
Flowrate, 1/s 141 177 212 247 283 318 353 424
Face Velocity, m/s 2.5 3.2 3.8 4.4 5.0 5.7 6.3 7.6
Throw Distance-1. (0.5 m/s), m 1.38 1.76 2.1 2.5 2.81 2.90 3.5 4.2
300
Throw Distance-2. (0.5 m/s), m 1.10 1.41 1.68 2.0 2.25 2.32 2.8 3.3
Total Pressure Loss, Pa 15.1 24.0 29.0 42.0 52.2 55 74.2 96.3
LEGEND
THROW DISTANCE - 1 - WITH CEILING EFFECT
DIFFUSERS 31
JET DIFFUSER
JET DIFFUSER
DIFFUSER
APPLICATION
Commonly used in wide open spaces where duct work is not
possible but requiring proper ventilation, the Jet Diffuser
(JD) is able to deliver air to localised targeted area over large
distance up to 50m.
CONSTRUCTION
• Design configurations:
• 2-way configuration
• 4-way configuration
• Throw distance up to 50 m
MATERIAL
DIFFUSERS 33
JET DIFFUSER
DIMENSIONAL DETAILS
DIMENSIONS
DIFFUSERS 34
JET DIFFUSER
TECHNICAL PERFORMANCE
• The throw length values quoted in the diagrams are valid for isothermal supply
air. Throw lengths depend considerably on; the temperature of the supply air,
Unit Volume Flowrate, m³/hr 250 400 500 800 1000 1400 1600 2000 2500
Neck Area (Eff.
Order Size, inch
Area) m²
Unit Volume Flowrate, l/s 70 112 140 224 280 392 448 560 700
Size
1 2 3 4
(mm)
L H LD HD L H LD HD L H LD HD L H LD HD
200 370 370 320 320 690 370 640 320 1010 370 960 320 1330 370 1280 320
250 420 420 370 370 790 420 740 370 1160 420 1110 370 1530 420 1480 370
300 470 470 420 420 890 420 840 420 1310 470 1260 420 1730 470 1680 420
350 520 520 470 470 990 520 940 470 1460 520 1410 470 1930 520 1880 470
DIFFUSERS 35
LINEAR DIFFUSER
EXTRUDED ALUMINIUM DIFFUSER
LINEAR DIFFUSER
DIFFUSER
APPLICATION
Our unique design of the adjustable deflector blades for
horizontal/vertical flow enable our Linear Slot Diffuser able
to provide the highest flexibility in throw adjustment under
most efficient operating requirement conditions (low noise and
pressure loss).
Both versatile and aesthetic, Linear Slot Diffusers are suitable for
supply and exhuast/return applications. It is also applicable for
heating, cooling and ventilation purpose.
FEATURES
CONSTRUCTION
• CUSTOMIZED SIZES
MATERIAL
GRILLES 37
LINEAR DIFFUSER
DIMENSIONAL DETAILS
DIFFUSERS 38
LINEAR DIFFUSER
DIMENSIONAL DETAILS
MEDIUM CAPACITY (X:20mm WIDTH SLOT) HIGH CAPACITY (X:25mm WIDTH SLOT)
Slot No FACE SIZE NECK SIZE CEILING OPENING FACE SIZE NECK SIZE CEILING OPENING
1 76 44 54 81 49 59
DIFFUSERS 39
LINEAR DIFFUSER
PATTERN ADJUSTMENT
ONE SLOT
HORIZONTAL LEFT
HORIZONTAL RIGHT
VERTICAL
FULLY DAMPERED
DIFFUSERS 40
LINEAR DIFFUSER
PATTERN ADJUSTMENT
TWO SLOT
OPPOSED
ONE WAY
FULLY DAMPERED
DIFFUSERS 41
LINEAR DIFFUSER
1 2 3 4
Collar size H SLOT X H SLOT X H SLOT X H SLOT X
H+4 H+45 H+45 H+45
(Ø)
100mm 150 195 100 150 195 124
150mm 200 245 100 200 245 124 200 245 45 200 245 204
150mm 200 245 100 200 245 134 200 245 179 200 245 224
200mm 250 295 134 250 245 179 250 245 224
250mm 300 345 134 300 345 179 300 345 224
DIFFUSERS 42
LINEAR DIFFUSER
PERFORMANCE DATA
AIRFLOW (CMH) 72 90 108 144 180 216 252 288 324 360 396 432 468 504 540 720 900 1080 1440 1800 2160
LD (20MM) NO FLOW RATE
20 25 30 40 50 60 70 80 90 100 110 120 130 140 150 200 250 300 400 500 600
OF SLOTS (L/S
S.P. (Pa) 4 7 9 16 25 35 47 61 76 93 112 132 153 177 201
1 NR 12 16 20 25 30 34 37 41 44 48 52 55 58 61 63
Throw (m) 4 4 5 7 8 10 12 13 15 17 18 20 22 23 25
S.P. (Pa) 5 8 12 18 24 32 40 49 59 71 83 96 110 194
2 NR 10 16 21 25 28 30 33 36 40 43 46 49 52 63
Throw (m) 4 5 5 6 7 9 10 11 12 13 14 16 17 23
S.P. (Pa) 8 11 15 20 25 31 37 45 52 61 70 125
3 NR 16 20 23 27 29 32 35 37 41 44 48 61
Throw (m) 5 5 6 7 7 8 9 10 11 11 12 16
S.P. (Pa) 4 5 6 7 8 9 16 25 35 61 93 132
4 NR 12 14 16 17 19 20 27 32 36 45 54 62
Throw (m) 7 7 7 7 7 8 9 11 14 19 25 31
AIRFLOW (CMH) 108 144 180 216 252 288 324 360 396 432 468 504 540 720 900 1080 1440 1800 2160 2520 2880
LD (25MM) NO FLOW RATE
30 40 50 60 70 80 90 100 110 120 130 140 150 200 250 300 400 500 600 700 800
OF SLOTS (L/S
S.P. (Pa) 10 17 26 37 50 65 81 99 118 140 163 188 214 370
1 NR 18 23 28 32 35 38 41 44 47 50 52 55 57 67
Throw (m) 4 5 6 7 8 10 11 13 14 15 17 18 20 26
S.P. (Pa) 7 10 14 19 24 30 37 44 52 60 69 78 134 204 287
2 NR 15 19 23 26 29 31 33 35 37 38 40 42 51 58 63
Throw (m) 3 4 5 6 7 8 9 10 11 11 12 13 18 23 28
S.P. (Pa) 4 6 7 9 12 15 17 21 24 28 52 83 123 226
3 NR 11 14 17 20 22 25 27 29 31 32 39 45 52 64
Throw (m) 4 5 6 6 7 8 9 9 10 11 14 18 22 29
S.P. (Pa) 5 6 7 8 14 21 29 49 74 104 138 177
4 NR 13 14 16 17 23 29 33 39 47 53 58 63
Throw (m) 4 5 5 6 8 9 11 15 18 22 26 30
LEGEND
LD - Linear Slot Diffuser
TEST PERFORMANCE
Units of the grilles have been tested at an independent N.A.T.A. accredited test laboratory in Australia. Test
reports can be provided on request. Throw and Noise Rating (NR) found in the performance data of this
catalogue is based on distance measured from the diffuser to the furthest point where the velocity is 0.25m/s
and room absorption of 10 dB in accordance to the recommendations of the Air Diffusion Council.
DIFFUSERS 43
LIGHT TROFFER
LIGHT TROFFER
DIFFUSER
APPLICATION
Offers a concealed means of air diffusion to suit all light-
fitting design. Fabricate to customise to suit light fitting. The
availability of the sizes width of 12mm, 20mm and 25mm
slot. For the side inlet will be standard for both single and
double sided model.
CONSTRUCTION
MATERIAL
DIFFUSERS 45
LIGHT TROFFER
PERFORMANCE DATA
SINGLE SIDE
SIZE (MM)
LENGTH FLOW (L/S) 14 22 24 27 33 38 42
600 SP (PA) 14 38 51 64 98 137 164
COLLAR NR 23 31 33 35 42 47 49
Ø150 SPREAD IN METRES 1.1 2.1 2.6 3.1 4 5 >5
LENGTH FLOW (L/S) 24 30 35 39 43 46 52 57
1200 SP (PA) 20 28 37 46 52 58 70 82
COLLAR NR 26 29 33 35 37 38 39 41
Ø150 SPREAD IN METRES 2 2.2 2.3 2.5 2.7 2.8 3.5 4.1
AIRFLOW (CMH 50.4 79.2 86.4 97.2 118.8 136.8 151.2 41
LEGEND
FLOW RATE - Primary Air Flow Rate (L/s)
S.P. - Supply Static Pressure (Pa)
THROW - Horizontal Throw in meters to a terminal velocity of 0.25 m/s (m)
NR - Noise Rating based upon room absorption of 10dB
SADDLE TYPE
SIZE (MM)
LENGTH FLOW (l/s) 24 28 33 38 45 55 66 76
600 SP (Pa) 9 16 23 30.5 40 52.5 72.5 100.5
COLLAR NR <16 21 25 29 33 37 40
Ø150 SPREAD IN METRES 0.3 0.6 0.9 2.25 2.65 3.05 3.45
LENGTH FLOW (l/s) 28 38 47 57 67 76 85 94
1200 SP (Pa) 4 7 10 15.5 21 27.5 34 41.5
COLLAR NR <16 16 17 21 26 30 32 35
Ø150 SPREAD IN METRES 1.6 1.9 2.1 2.3 2.5 3.3 3.6
LENGTH FLOW (l/s) FLOW (l/s) 38 47 57 67 76 85 94
1200 SP (Pa) 3 4 6 7.5 10 12.5 15 19.3
COLLAR NR 17 22 27 28 31
Ø150 SPREAD IN METRES 1.2 1.5 1.7 1.9 2.1 2.9 3.2
AIRFLOW (CMH) 86.4 100.8 118.8 136.8 162 198 237.6 273.6
LEGEND
FLOW RATE - Primary Air Flow Rate (L/s)
S.P. - Supply Static Pressure (Pa)
THROW - Horizontal Throw in meters to a terminal velocity of 0.25 m/s (m)
NR - Noise Rating based upon room absorption of 10dB
TEST PERFORMANCE
Units of the grilles have been tested at an independent N.A.T.A. accredited test laboratory in Australia. Test
reports can be provided on request. Throw and Noise Rating (NR) found in the performance data of this
catalogue is based on distance measured from the diffuser to the furthest point where the velocity is 0.25m/s
and room absorption of 10 dB in accordance to the recommendations of the Air Diffusion Council.
DIFFUSERS 46
FIXED LOUVRE
EXTRUDED ALUMINIUM RETURN/EXHAUST LOUVRE
FIXED LOUVRE
LOUVRES
APPLICATION
FEATURES
CONSTRUCTION
MATERIAL
LOUVRES 48
FIXED LOUVRE
DIMENSIONAL DETAILS
LOUVRES 49
FIXED LOUVRE
PERFORMANCE DATA
AIRFLOW (CMH) 288 324 360 540 720 900 1080 1260 1440 1620 1800 2160 2520 2880 3240 3600 3960 4320 4680 5040 5400 7200
BG SIZE FLOW
80 90 100 150 200 250 300 350 400 450 500 600 700 800 900 1000 1100 1200 1300 1400 1500 2000
(mm) RATE (L/s)
S.P. (Pa) 2 5 10 15 22 30 39 49 60 86 117 153 193 238 288 342
240 x 240 NR - 10 18 25 30 35 38 42 45 51 55 59 63 66 69 72
Throw (m) 6 8 10 12 14 16 18 20 22 25 29 32 34 37 40 42
S.P. (Pa) 1 3 4 6 8 10 13 15 22 30 39 50 61 74 88 104
345 x 330 NR - 12 18 24 28 32 36 39 44 49 53 56 59 62 65 67
Throw (m) 6 8 9 10 12 13 14 16 18 20 23 25 27 29 30 32
S.P. (Pa) 1 2 2 3 4 5 6 9 12 15 18 22 26 30 35 40
460 x 460 NR 13 18 23 26 30 33 38 43 47 50 53 56 59 61 64 66
Throw (m) 6 7 8 9 10 11 13 14 16 17 19 20 22 23 24 25
S.P. (Pa) 1 1 1 2 2 3 4 5 6 8 9 11 13 15 17 30
570 x 570 NR 14 19 23 26 29 34 39 43 46 49 52 55 57 59 61 70
Throw (m) 5 6 7 7 8 9 11 12 13 14 15 16 17 18 19 24
S.P. (Pa) - - 1 1 1 1 2 2 3 4 4 5 6 7 8 15
685 x 685 NR 11 15 19 23 26 31 36 39 43 46 49 51 54 56 58 67
Throw (m) 4 4 5 5 6 7 8 9 10 11 12 13 13 14 15 19
S.P. (Pa) - - - - 1 1 1 1 2 2 3 3 4 4 7
815 x 815 NR 12 16 19 23 28 32 36 40 43 46 48 50 53 55 64
Throw (m) 3 3 4 4 5 6 7 7 8 9 10 10 11 11 14
S.P. (Pa) - - - - - 1 1 1 1 1 2 2 2 4
950 x 950 NR 13 17 20 25 30 33 37 40 43 45 48 50 52 61
Throw (m) 2 2 3 4 4 5 6 6 7 7 8 8 9 11
S.P. (Pa) - - - - - - - 1 1 1 1 1 1 2
1082 x 1082 NR 11 14 17 23 27 31 34 38 40 43 45 47 49 59
Throw (m) 1 1 2 2 3 4 4 5 5 6 6 7 7 9
S.P. (Pa) - - - - - - - - 1 1 1 1 2
1210 x 1210 NR 12 15 21 25 29 32 36 38 41 43 45 47 57
Throw (m) 1 1 2 2 3 3 4 4 5 5 5 6 7
LEGEND
FL - Fixed Louvre
TEST PERFORMANCE
Our Fixed Louvres have been tested at an independent N.A.T.A. accredited test laboratory in Australia. Test
reports can be provided on request. Throw and Noise Rating (NR) found in the performance data of this
catalogue is based on distance measured from the diffuser to the furthest point where the velocity is 0.25m/s
and room absorption of 10 dB in accordance to the recommendations of the Air Diffusion Council.
LOUVRES 50
EXTERNAL AIR LOUVRE
EXTRUDED ALUMINIUM RETURN/EXHAUST LOUVRE
EXTERNAL AIR LOUVRE
LOUVRES
APPLICATION
External Air Louvres are mainly used in exterior installations for
air discharge or intake, with protection against water ingress.
FEATURES
CONSTRUCTION
MATERIAL
LOUVRES 52
EXTERNAL AIR LOUVRE
DIMENSIONAL DETAILS
PERFORMANCE DATA
AIRFLOW (CMH) 900 1080 1260 1440 1620 1800 1980 2160 2340 2520 2700 2880 3060 3240 3420 3600 3960 4320 4680 5040 5400 7200
EL IZE FLOW
250 300 350 400 450 500 550 600 650 700 750 800 850 900 950 1000 1100 1200 1300 1400 1500 2000
(MM) RATE (L/s)
S.P. (Pa) 1 1 2 2 3 3 4 4 5 6 6 7 8 9 9 10 12 14 16 18 20 31
650 1 3 3 4 4 5 5 5 6 6 7 7 7 8 8 8 9 9 9 10 10 11
LEGEND
EL - External Louvre
FLOW RATE - Primary Air Flow Rate (L/s)
S.P. - Supply Static Pressure (Pa)
THROW - Horizontal Throw in meters to a terminal velocity of 0.25 m/s (m)
NR - Noise Rating based upon room absorption of 10dB
TEST PERFORMANCE
Our External Louvres have been tested at an independent N.A.T.A. accredited test laboratory in Australia.
Test reports can be provided on request. Throw and Noise Rating (NR) found in the performance data of this
catalogue is based on distance measured from the diffuser to the furthest point where the velocity is 0.25m/s
and room absorption of 10 dB in accordance to the recommendations of the Air Diffusion Council.
LOUVRES 53
BALL JET NOZZLE
BALL JET NOZZLE
NOZZLES
APPLICATION
Used in areas where ceiling air distribution solutions is
impossible, Ball Jet Nozzle (LA-BJD) is capable in directing
large volume of air over longer distances.
Design primary for spot cooling and high/long air throw, the
nozzle comes with adjustable flow deflection up to 45° multi-
directional and a built-in hit-and-miss damper.
CONSTRUCTION
• Capability of:
• Spot cooling
MATERIAL
extruded aluminium
Finished (FF160/23/C3)
DIMENSIONAL DETAILS
DIMENSIONS
NOZZLES 55
BALL JET NOZZLE
TECHNICAL PERFORMANCE
Grille Neck
Air Velocity, m/s 2.0 3.0 4.0 5.0 6.0 7.0 8.0 10.0
Size (mm)
Airflow Volume, m³/hr 130 196 262 323 393 460 525 655
Airflow Volume, m³/hr 233 350 467 583 700 816 933 1,166
Airflow Volume, m³/hr 365 548 730 913 1,095 1,280 1,460 1,825
250 Dia Throw Distance, m 4.6 7.0 9.5 11.6 13.8 16.2 18.5 25.4
Airflow Volume, m³/hr 526 790 1,052 1,315 1,580 1,842 2,105 2,632
NOZZLES 56
JET NOZZLE
JET NOZZLE
LOUVRES
APPLICATION
CONSTRUCTION
• Capability of:
• Long throw up to 30 m
MATERIAL
NOZZLES 58
JET NOZZLE
NOZZLES
MOUNTING DETAILS
DIMENSIONAL DETAILS
SPECS ØD ØA ØC L H2
100 98 139 45 63 83
NOZZLES 59
JET NOZZLE
THROW PATTERN
VERTICAL THROW
NOZZLES 60
JET NOZZLE
TECHNICAL PERFORMANCE
LEGEND
LT - row distance, m
V - Volume Flow rate, L/s
NC - Noise Criteria
∆P - Total Pressure Loss, Pa
NR - Noise Rating based upon room absorption of 10dB
PERFORMANCE DATA
MM) TOT. PRESS (MMAQ) 0.5 1.7 3.0 6.5 10.5 13.5 17.0 21.0
CMH 57 95 133 190 247 285 323 380
Ø160 THROW (M) 3.0-7.5 5.5-11.0 6.0-13.0 11.5-24.0 14.0-30.0 18.0-39.0 20.0-45.0 21.5-51.0
NC - - - 20 25 30 34 37
CMH 99 165 231 330 429 495 561 660
Ø200 THROW (M) 5.0-10.0 7.5-16.0 11.0-22.5 16.0-31.0 20.0-40.0 22.5-45.0 25.0-50.0 30.0-57.0
NC - - - 22 29 33 37 42
CMH 157 261 366 523 680 784 889 1046
Ø250 THROW (M) 6.0-12.0 10.0-20.0 14.0-27.0 19.0-40.0 25.0-50.0 30.0-55.0 32.0-57.0 36.0-62.0
NC - - - 23 30 35 40 44
CMH 257 428 599 856 1113 1284 1455 1712
Ø315 THROW (M) 8.0-16.0 12.0-25.0 16.0-35.0 23.0-47.0 30.0-55.0 35.0-60.0 40.0-65.0 45.0-70.0
NC - - - 27 35 40 44 47
CMH 449 748 1047 1496 1944 2244 2543 2991
Ø400 THROW (M) 10.0-20.0 16.0-32.0 22.0-45.0 32.0-58.0 40.0-66.0 47.0-73.0 51.0-77.0 57.0-83.0
NC - - 25 36 42 46 48 52
DIFFUSERS 61
NON RETURN DAMPER
NON RETURN DAMPER
DAMPERS
APPLICATION
CONSTRUCTION
horizontal configuration
MATERIAL
Surface finishing • 0.5 – 1.2 mm aluminium steel (For length <600 mm)
DIMENSIONAL DETAILS
DAMPERS 63
NON RETURN DAMPER
LEAKAGE PERFORMANCE
FOR LOW LEAKAGE CONSTRUCTION
Static Pressure Drop (Pa) Static Pressure Drop (in WC) NRD Leakage (CFM) Leakage Per Sq Ft (CFM/Sqft)
101 0.4 0 0
184 0.7 0 0
220 0.9 0 0
285 1.1 0 0
335 1.3 0 0
415 1.7 0 0
470 1.9 0 0
570 2.3 0 0
DAMPERS 64
OPPOSED BLADE
DAMPER
OPPOSED BLADE DAMPER
DAMPERS
APPLICATION
CONSTRUCTION
head adjustment
OPPOSED BLADE DAMPER
MATERIAL
rustproof undercoat
• Matt black
DAMPERS 66
VOLUME CONTROL
DAMPER
VOLUME CONTROL DAMPER
DAMPERS
APPLICATION
With its opposed blade operation closing system, volume
control damper (LA-VCD) is designed for controlling air flow
and pressure in HVAC systems. Designed to operate with
opposed blade action (providing better aerodynamics),
volume control damper provides better balancing control or
airflow rates.
CONSTRUCTION
: Bare shaft
MATERIAL
(Size dependant)
VCD-S/C
Blade • 0.7 – 1.0 mm galvanized steel
(Size dependant)
VCD-TDF
DAMPERS 68
VOLUME CONTROL DAMPER
MOUNTING DETAILS
DAMPERS 69
FIRE DAMPER (V)
FIRE DAMPER (VERTICAL)
DAMPERS
APPLICATION
Designed to impede the spread of fire or combustible
products. This range of fire dampers find its application in
commercial building construction where ventilation, heating,
cooling or air conditioning systems are employed. Certified
by Singapore SS333:2012 and listed under the PSB’s Product
Listing Scheme.
CONSTRUCTION
INTEGRITY
• 260 mins
MAX SIZE FOR SINGLE MODULES
• 1200mm (w) x 1200mm (ht)
MATERIAL
/stainless steel
/ stainless steel
/ stainless steel
LA-VCD-TDF
DAMPERS 71
FIRE DAMPER (VERTICAL)
MOUNTING DETAILS
DAMPERS 72
FIRE DAMPER (VERTICAL)
ILLUSTRATION
DAMPERS 73
FIRE DAMPER (VERTICAL)
ILLUSTRATION
DAMPERS 74
FIRE DAMPER (VERTICAL)
ILLUSTRATION
DAMPERS 75
FIRE DAMPER (VERTICAL)
ILLUSTRATION
DAMPERS 76
FIRE DAMPER (H)
FIRE DAMPER (HORIZONTAL)
DAMPERS
APPLICATION
Designed to impede the spread of fire or combustible
products. This range of fire dampers find its application in
commercial building construction where ventilation, heating,
cooling or air conditioning systems are employed. Certified
by Singapore SS333:2012 and listed under the PSB’s Product
Listing Scheme.
CONSTRUCTION
INTEGRITY
• 260 mins
1 X 2 MULTI-MODULES
• 1200 mm x 1200 mm
MATERIAL
LA-VCD-TDF
DAMPERS 78
FIRE DAMPER (HORIZONTAL)
MOUNTING DETAILS
DAMPERS 79
FIRE DAMPER (HORIZONTAL)
DRAWING DETAILS
DAMPERS 80
FIRE DAMPER (HORIZONTAL)
DRAWING DETAILS
DAMPERS 81
FIRE DAMPER (HORIZONTAL)
DRAWING DETAILS
DAMPERS 82
FIRE DAMPER (HORIZONTAL)
DRAWING DETAILS
DAMPERS 83
PRE-INSULATED DUCTBOARD
DUCTBOARD
PRE-INSULATED DUCTBOARD
APPLICATION
Ideal for environments that require robust and durable ducting with
effective thermal insulation to maintain temperature stability.
MATERIAL
KEY PROPERTIES
LA-VCD-TDF
DUCT BOARD 85
PRE-INSULATED DUCTBOARD
SPECIFICATIONS
Brand - ASA
LA-VCD-TDF
DUCT BOARD 86
ONE STOP ACMV CENTER
FOR DUCTING, GRILLES
AND DIFFUSERS
(MAIN OFFICE):
BLK 4 DEFU SOUTH STREET 1,
#04-14/15, SINGAPORE 533756
HOTLINE: 68166615
EMAIL: SALES@SUNLAND.COM.SG