0% found this document useful (0 votes)
715 views2 pages

Centrifugal Pump TDH Calculation

The document discusses calculating the total dynamic head (TDH) for centrifugal pumping systems. TDH is the sum of all opposing and aiding elements acting on the pump. Opposing elements include static discharge head, suction lift, friction, and velocity head. Aiding elements include static suction head and pressure in closed vessels. An example calculation is provided that adds up all opposing (120 ft) and aiding (20 ft) elements to get a TDH of 100 ft. Correction factors for fluid properties are also considered.

Uploaded by

rajbhar_s
Copyright
© Attribution Non-Commercial (BY-NC)
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
715 views2 pages

Centrifugal Pump TDH Calculation

The document discusses calculating the total dynamic head (TDH) for centrifugal pumping systems. TDH is the sum of all opposing and aiding elements acting on the pump. Opposing elements include static discharge head, suction lift, friction, and velocity head. Aiding elements include static suction head and pressure in closed vessels. An example calculation is provided that adds up all opposing (120 ft) and aiding (20 ft) elements to get a TDH of 100 ft. Correction factors for fluid properties are also considered.

Uploaded by

rajbhar_s
Copyright
© Attribution Non-Commercial (BY-NC)
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 2

DA ENGINEERING DATA SHEET ATA

Total Dynamic Head


Date 04/01/99 Supersedes 06/01/66 No. 6E

Careful calculation of the total dynamic head (TDH) is one of the most important factors in selecting the proper size of a Chempump. The total dynamic head of any centrifugal pumping system consists of all static discharge and suction heads, all dynamic heads, all friction heads, velocity heads, and entrance and exit losses -- properly added together. The basic rule is to add all elements which act to oppose pumping action (static discharge head, suction lift, suction supply under vacuum, friction, etc.) and then add up all elements which act to aid pumping action (static suction head, suction supply under pressure, etc.). All factors must be expressed in the same units, usually feet. Total dynamic head is then the difference between opposing and aiding elements. Correction factors for specific gravities of fluids other than water must also be taken into consideration. Below are lists of the aiding and opposing elements most often encountered in centrifugal pumping systems. Elements Aiding Pumping Action Static suction head (when free level of supply source is above pump suction centerline). Pressure in closed supply vessel. Vacuum in closed discharge receiver. Static discharge drop (when free level of discharge receiver is below pump discharge centerline). Elements Opposing Pump Action Static suction lift (when free level of supply source is below pump suction centerline). Vacuum in closed supply vessel. Pressure in closed discharge receiver. Static discharge head (when free level of discharge receiver is above pump discharge centerline). Frictional heads due to resistance offered by piping, fittings, valves, etc., in both suction and discharge sides). Velocity head (equivalent to head necessary to accelerate pumped fluid. Equal numerically to the height through which pumped fluid would have to fall to acquire velocity at which it is pumped. Given by formula, velocity head = V2 , where V is velocity of pumped fluid (feet per second) and 2g g = 32.2 (feet/second/second). Entrance and exit losses due to inefficient transition from pressure heads to velocity heads, such as when fluids leave a supply vessel and enter a pipe, or vice versa. Friction losses, velocity head losses, and entrance and exit losses can be found in an hydraulic data book.
EDS 6E - Page 1

Example:

10 psig

Low Pressure Boiler 22" Hg

Condensate Storage 20' Gate Valves 75 Feet 1 1/2 inch Steel Pipe

50'

25 Feet 2 inch Steel Pipe

Required: CHEMPUMP to handle 60 gpm water at 150 F.

Elements Aiding Static Suction Head Elements Opposing Static Discharge Head Supply Vessel Vacuum (Inches Hg x 1.13 = ft., water) Discharge Vessel Pressure (Psig x 2.31 = ft., water) Friction losses (From Cameron hydraulic data) 2-inch line piping and fitting 1 1/2-inch line piping and fittings Friction Head Losses Entrance Loss

Opposing

Aiding 20 ft.

50 ft. 22 Hg. = 24.9 ft. 10 psig = 23.1 ft.

1.9 ft. 18.5 ft. 1.4 ft. .3 ft. ----------------

Total Head Opposing Total Head Aiding Total Dynamic Head (Opposing vs. Aiding)
EDS 6E - Page 2

120 ft. 20 ft. 120 ft. - 20 ft. = 100 ft.