W100
WEIGHT INDICATOR
AL COU
ON N
TI
NA
CI
NEW
L
ZEALAND
RES
ON W
SU
G
EI
A
HT E
S AND M
DESCRIPTION MAIN FUNCTIONS
Weight indicator in DIN box suitable for front panel mounting. Connections to:
Dimensions: 96x48x130 mm (drilling template: 92x45 mm). - PLC via analog output (on request);
6-digit semi-alphanumeric red LED display (14 mm height). - PC/PLC via RS485/RS232 (up to 99 instruments with line
8 signalling LED. repeaters, up to 32 without line repeaters);
4-key keyboard. - remote display and printer via RS485/RS232;
IP54 front panel protection rating (IP65 front optional). - up to 8 load cells in parallel by junction box;
Real-time clock/calendar with buffer battery. - intelligent junction box or other multichannel instruments: allow
the use of advanced functions as digital equalization, load
Removable screw terminal blocks. distribution analysis and automatic diagnostics.
The instrument can be configured and managed using the free - IoT gateway for cloud connection via RS485.
“Instrument Manager” PC software, which you can download from
www.laumas.com. Digital filter to reduce the effects of weight oscillation.
Theoretical calibration (via keyboard) and real calibration (with
sample weights and the possibility of weight linearization up to
8 points).
INPUTS/OUTPUTS AND COMMUNICATION Tare weight zero setting.
Automatic zero setting at power-on.
RS485/RS232 serial ports for communication via protocols Gross weight zero tracking.
ModBus RTU, ASCII Laumas or continuous one way transmission. Semi-automatic tare (net/gross weight) and preset tare.
5 relay outputs controlled by the setpoint values or via protocols Semi-automatic zero.
(4 outputs if analog output is present). Displaying of the maximum weight value reached (peak).
3 optoisolated PNP digital inputs: status reading via serial Direct connection between RS485 and RS232 without converter.
communication protocols (2 inputs if analog output is present). Hysteresis and setpoint value setting.
1 load cell dedicated input. Weight value printing with date and time via keyboard or external
contact.
Current or voltage 16 bit optoisolated analog output (option on request).
The indicator can be used as a remote display with setpoint.
12 groups selection by 5 setpoint via external selector switch or
contact (option on request).
Labeling machine management.
Approved versions for legal for trade use
System parameters management protected by qualified access via
software (password), hardware or fieldbus.
Weight subdivisions displaying (1/10 e).
Three operation mode: single interval or multiple range or
multi-interval.
Net weight zero tracking.
Calibration.
Alibi memory (option on request).
The following values can be printed via keyboard or external contact:
gross weight, net weight, tare, preset tare, date, time, ID code (alibi
On request: label support for initial verification memory).
Re v. 0. 0
LAUMAS Elettronica srl • Phone: (+39) 0521 683124 • Fax (+39) 0521 681091 ISO 9001
UFFICIO VENDITE ITALIA: commerciale@laumas.it • EXPORT SALES DEPARTMENT: sales@laumas.it ISO 14001 www.laumas.com
W100
WEIGHT INDICATOR
CERTIFICATIONS
OIML R76:2006, class III, 3x10000 divisions, 0.2 μV/VSI / OIML R61 - WELMEC Guide 8.8:2011 (MID)
UL Recognized component - Complies with United States and Canada regulations
Complies with the Eurasian Customs Union regulations
Equivalent of the CE marking for the United Kingdom
NMI Trade Approved - Complies with Australian market regulations for legal for trade use
Complies with New Zealand regulations for legal for trade use
NEW
ZEALAND
Complies with United Kingdom regulations for legal for trade use
Complies with the Brazilian regulations for legal for trade use
AL COU
ON N
TI
NTEP - nmax 10000 - Class III/IIIL - Complies with United States regulations for legal for trade use
NA
CI
L
RES
ON W
SU
G
E
HT E
I
S AND M
Complies with Chinese market regulations for legal for trade use
CERTIFICATIONS ON REQUEST
Conformity assessment (initial verification) in combination with Laumas weighing module ( - )
Support for metric label (dimensions: 124x77x1.5 mm)
Complies with the regulations of the Russian Federation for legal for trade use
Re v. 0. 0
LAUMAS Elettronica srl • Phone: (+39) 0521 683124 • Fax (+39) 0521 681091 ISO 9001
UFFICIO VENDITE ITALIA: commerciale@laumas.it • EXPORT SALES DEPARTMENT: sales@laumas.it ISO 14001 www.laumas.com
W100
WEIGHT INDICATOR
TECHNICAL FEATURES
Power supply and consumption 12÷24 VDC ±10%; 5 W
Number of load cells • Load cells supply up to 8 (350 Ω) - 4/6 wires • 5 VDC/120 mA
Linearity • Analog output linearity <0.01% full scale • <0.01% full scale
Thermal drift • Analog output thermal drift <0.0005% full scale/°C • <0.003% full scale/°C
A/D Converter 24 bit (16000000 points) - 4.8 kHz
Divisions (with measurement range ±10 mV and sensitivity 2 mV/V) ±999999 • 0,01 μV/d
Measurement range ±39 mV
Usable load cells sensitivity ±7 mV/V
Conversions per second 300/s
Display range ±999999
Decimals • Display increments 0÷4 • x1 x2 x5 x10 x20 x50 x100
Digital filter • Readings per second 10 levels • 5÷300 Hz
Relay outputs 5/4 - max 115 VAC/150 mA
Optoisolated digital inputs 3/2 - 5÷24 VDC PNP
Serial ports RS485, RS232
Baud rate 1200, 2400, 4800, 9600, 19200, 38400, 115200 (bit/s)
16 bit = 65535 divisions. 0÷20 mA; 4÷20 mA (up to 300 Ω)
Optoisolated analog output (option on request)
0÷10 V; 0÷5 V; ±10 V; ±5 V (min 10 kΩ)
Humidity (condensate free) 85%
Storage temperature -30 °C +80 °C
Working temperature -20 °C +60 °C
Relay outputs 5/4 - max 30 VAC, 60 VDC/150 mA
Working temperature -20 °C +50 °C
Equipment to be powered by 12-24 VDC LPS or Class 2 power source
METROLOGICAL SPECIFICATIONS OF
OIML NTEP INMETRO
TYPE APPROVED INSTRUMENTS
EU: 2014/31/UE; OIML R76:2006; EN45501:2015
Russian Federation: GOST OIML R76-1-2011
United Kingdom: Non-automatic Weighing
Instrument Regulations 2016
USA: NIST HANDBOOK 44, Brazil: Portaria Inmetro
Applied standards by region Australia: National Measurement Regulations 1999 2020; NCWM PUB 14, 2021 N°157/2022
New Zealand: Weights and Measures
Regulations 1999
China: Law on Metrology of the People’s
Republic of China
single interval, multi-interval, single interval, multi-interval,
Operation mode single interval, multi-interval, multiple range
multiple range multiple range
Accuracy class III or IIII III or IIIL III
Maximum number of scale
10000 (class III); 1000 (class IIII) 10000 (class III/IIIL) 10000 (class III)
verification divisions
Minimum input signal for scale
0.2 μV/VSI 0.2 μV/VSI
verification division
Working temperature -10 °C +40 °C -10 °C +40 °C (+14 °F +104 °F) -10 °C +40 °C
Re v. 0. 0
LAUMAS Elettronica srl • Phone: (+39) 0521 683124 • Fax (+39) 0521 681091 ISO 9001
UFFICIO VENDITE ITALIA: commerciale@laumas.it • EXPORT SALES DEPARTMENT: sales@laumas.it ISO 14001 www.laumas.com
W100
WEIGHT INDICATOR
OPTIONS ON REQUEST
ACCESSORIES CODE
Label support for initial verification.
IP65 panel gasket. OPZW48X96IP65
INTERFACES
Optoisolated 16 bit analog output.
OPZW1ANALOGICA
One input and one output not available.
Additional RS485 port.
OPZW1RS485
One input and one output not available.
Weight reading from 0-10 VDC input (15 kΩ). OPZWING010
Weight reading from 4-20 mA input (120 Ω). OPZWING420
Select one option among those marked with an asterisk.
EXPANSIONS
12 groups selection by 5 setpoint via external selector switch. EC
12 groups selection by 5 setpoint via external contact. E
Simultaneous use of E/EC option with the analog output. OPZWAEC
External 5-relay module to increase the capacity of SPDT contacts to
RELE5M
115 VAC/2 A.
Select one option among those marked with an asterisk.
APPLICATIONS - SOFTWARE
Alibi memory. OPZWALIBI
Re v. 0. 0
The Company reser ves the right to make changes to the technical data, drawings and images without notice.
LAUMAS Elettronica srl • Phone: (+39) 0521 683124 • Fax (+39) 0521 681091 ISO 9001
UFFICIO VENDITE ITALIA: commerciale@laumas.it • EXPORT SALES DEPARTMENT: sales@laumas.it ISO 14001 www.laumas.com