SALUPO

INNOVATION TECHNOLOGY
CERTIFICATE No. - CERTIFICATO N. SALU2490Q1801

WE HEREBY CERTIFY THAT THE QUALITY MANAGEMENT SYSTEM OF


SI CERTIFICA CHE IL SISTEMA DI GESTIONE DELLA QUALITÀ DI

SALUPO S.r.l.
REGISTERED OFFICE - SEDE LEGALE
OPERATIVE UNIT - UNITÀ OPERATIVA
Contrada Pietra di Roma, Vicolo VI, 2 -98070, Torrenova (Me) - Italia

IS IN COMPLIANCE WITH THE STANDARD


È CONFORME ALLA NORMA

ISO 9001:2015
FOR THE FOLLOWING ACTIVITIES
PER LE SEGUENTI ATTIVITÀ

Design and manufacturing of electronic devices for electric pumps, electric panels and industrial machines;
assembly of electronic components on printed circuit boards. Design of photovoltaic systems
Progettazione e produzione di dispositivi elettronici per elettropompe, quadri elettrici e macchine
industriali; assemblaggio di componenti elettronici su circuiti stampati. Progettazione di impianti
fotovoltaici

IAF SECTOR (SETTORE IAF): 19

André Sant
Director
First Issue The use and the validity of this Certificate shall satisfy the Requirements of EuCI “Rules for
Prima Emissione Management System Certification”. Please visit www.euci.org to check the validity of this
2018-09-18 Certificate or scan the QR Code with your smartphone or tablet. La validità e l’uso del presente
Certificato è subordinata al rispetto dei Requisiti EuCI contenuti nel “Regolamento per la
Certificazione dei Sistemi di Gestione”. Si prega di controllare su www.euci.org lo stato del
Current Issue Certificato o scansionare il QR Code con il proprio smartphone o tablet.
Emissione Corrente
EuCI is accredited by ESYD under Certificate No. 831 for Management System Certification. For details
2024-09-11 about the Accreditation Scope please visit www.esyd.gr. EuCI è accreditato da ESYD con numero di
Certificato 831 per la Certificazione dei Sistemi di Gestione. Per dettagli sul campo d'applicazione
dell'Accreditamento si prega di visitare il sito www.esyd.gr.
Expiry Date
EuCI European Certification Institute Ltd - 2nd Floor Tower Business Centre - Tower Street - Swatar -
Scadenza BKR 4013 - Malta
2027-09-17 WWW.EUCI.ORG

fo.QP09.52 rev. 1
Electromechanical control panels

IMPEDANCE 1 RANGE 3÷200HP


Stator impedance starting electromechanical control panel 1 motor with voltmeter and ammeter

GENERAL SPECIFICATIONS PROTECTIONS


· Operating voltage 400Vac ±10% 50/60Hz · Maximum current protection con allarme
· General disconnecting switch with door lock
· Selector switch for automatic -0- manual operation
· Start-stop button for manual operation
· Adjustable impedance timer
· Running Led light
· Overload Led light
· Analog voltmeter 72x72
· Voltmeter selector switch
· Analog ammeter 72x72
· Auxiliary circuit protection fuse
· Transformer for auxiliary circuit
· Motor protection fuse
· N°2 contactors
· Three-phase impedance with thermostat
· Thermal relay (internal reset)
· Connection terminal board
· External metal box
· Protection degree IP55
· Operating temperature -5/+40°C

INPUTS / OUTPUTS
· N°2 very low voltage input for pressure switch or float switches
(minimum/maximum level)

116
THREE-PHASE 400Vac ±10% 50/60Hz
CODE TYPE POWER OPERATING DIMENSIONS mm WEIGHT BOX
kW Hp CURRENT [A] A-H L-W P-D Kg

SQ701.00 IMPEDANCE 1 400 3 2,2 3 5,5÷8 500 400 230 11 50


SQ701.01 IMPEDANCE 1 400 5,5 4 5,5 9÷12,5 500 400 230 20 50
SQ701.02 IMPEDANCE 1 400 7,5 5,5 7,5 11÷16 500 400 230 20 50
SQ701.03 IMPEDANCE 1 400 10 7,5 10 14÷20 500 400 230 23 50
SQ701.19 IMPEDANCE 1 400 12,5 9,2 12,5 20÷25 500 400 230 23 50
SQ701.04 IMPEDANCE 1 400 15 11 15 23÷28 500 400 230 25 50
SQ701.20 IMPEDANCE 1 400 17,5 13 17,5 27÷32 500 400 230 26 50
SQ701.05 IMPEDANCE 1 400 20 15 20 30÷36 600 400 230 27 60
SQ701.06 IMPEDANCE 1 400 25 18,5 25 40÷50 700 500 240 35 70
SQ701.07 IMPEDANCE 1 400 30 22 30 47÷57 700 500 240 37 70
SQ701.21 IMPEDANCE 1 400 35 26 35 54÷65 700 500 240 37 70
SQ701.08 IMPEDANCE 1 400 40 30 40 62÷73 700 500 240 41 70
SQ701.09 IMPEDANCE 1 400 50 37 50 70÷90 800 600 290 53 80
SQ701.10 IMPEDANCE 1 400 60 45 60 50÷200 1000 800 370 87 103
SQ701.11 IMPEDANCE 1 400 70 51,5 70 50÷200 1000 800 370 92 103
SQ701.22 IMPEDANCE 1 400 75 55 75 50÷200 1000 800 370 92 103
SQ701.12 IMPEDANCE 1 400 80 60 80 50÷200 1000 800 370 95 103
SQ701.13 IMPEDANCE 1 400 90 66 90 50÷200 1000 800 370 104 103
SQ701.14 IMPEDANCE 1 400 100 75 100 50÷200 1000 800 370 104 103
SQ701.15 IMPEDANCE 1 400 125 92 125 55÷250 1200 800 370 122 122
SQ701.16 IMPEDANCE 1 400 150 110 150 160÷630 1800 800 470 197 185
SQ701.17 IMPEDANCE 1 400 180 132 180 160÷630 1800 800 470 207 185
SQ701.18 IMPEDANCE 1 400 200 150 200 160÷630 1800 800 470 212 185

OPTIONALS
CODE TYPE
OP100.04/4 Wired lack, sequence and asymmetry of phases relay
OP100.04/5 Wired lack, sequence and asymmetry of phases relay, minimum and maximum voltage
OP100.05/1 Wired three-phase surge arrester type 2
OP100.15/024 Wired hour counter 24Vac 48x48
OP100.15/110 Wired hour counter 110Vac 48x48
OP100.16/1 Wired analog daily timer 72x72 without reserve
OP100.16/1T Wired analog daily timer 72x72 without reserve (timed function)
OP100.16/2 Wired analog daily timer 72x72 with reserve
OP100.18 Wired starting delay timer (supply mains waiting)
OP100.19/4 Wired module GSM 4 inputs/4 outputs
OP100.09/2 Wired lithium battery 3,7Vdc 600mAh
OP331.230 Wired LEVEL 230Vac control relay
OP100.01 3 level probes kit
OP100.17/024 Wired 24Vac relay complete with socket
OP210.01 Wired very low voltage input for motor klixon
OP200.01 Alarm output 24Vac and pure contact
OP100.13/1 Wired siren shut-off button
OP100.13/1/24 Wired siren 24Vac/dc
OP100.13/2/24L Wired flashing Led lamp 24Vac
SS100.01 Visual and acoustic alarm indicator (BASIC ALARM VA 024) see page 20
SS101.01 Visual and acoustic alarm indicator with buffer battery (TOP ALARM VAB 230) see page 19
For more optionals see page 126

STANDARD CONTROL PANEL WITH OPTIONAL: CONTROL PANEL WITH OPTIONAL:


CONTROL PANEL OP331.230 OP200.01

COMMON USE CLEAN WATER (EMPTYNG) CLEAN WATER (FILLING) SEWAGE COMPONENTS KEY
1 4 4 5
Float switch for clean water
X-1
X-2
X-3
X-4

X-1
X-2
X-3
X-4
X-5

X-1
X-2
X-3
X-4
X-5

x-1
x-2
x-3
x-4
x-5
x-6

Float switch for sewage

Level probes
MAX
START/
STOP MIN
COM

START
MAX
MIN START/
STOP STOP
COM

The addition of some optionals can imply changes on the size of the control panel. For further details please contact our technical/commercial department.