RTD Assembly With Sanitary Connection: How To Order Example

The Baumer R03 RTD Assembly is designed for sanitary applications, featuring options for element type, range, accuracy, wire configuration, and sheath diameter. It includes various terminal head types and conduit entry options, with a standard version offering a temperature range of -200°C to 450°C and Class 'B' accuracy. The assembly is suitable for food industries and includes features like a weatherproof enclosure and optional transmitter output.

Uploaded by

David Iglesias
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
14 views1 page

RTD Assembly With Sanitary Connection: How To Order Example

The Baumer R03 RTD Assembly is designed for sanitary applications, featuring options for element type, range, accuracy, wire configuration, and sheath diameter. It includes various terminal head types and conduit entry options, with a standard version offering a temperature range of -200°C to 450°C and Class 'B' accuracy. The assembly is suitable for food industries and includes features like a weatherproof enclosure and optional transmitter output.

Uploaded by

David Iglesias
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 1

Baumer

R03
RTD Assembly With Sanitary Connection

How To Order Example

Basic Model R03


Optional Extras
No of Element 1 Simplex (Standard) 2 Duplex X
Element type P1 Pt- 100
Range C -200°C till 450°C (Standard) X
Accuracy A Class ‘A’ B Class ‘B’ (Standard) X
Wire Configuration
2 2 Wire system 3 3 Wire system (Standard) X
4 4 Wire system
Sheath Diameter
03 3.0 mm 06 6.0 mm (Standard)
XX
05 4.5 mm 08 8.0 mm
Sheath Material
GOST - R 1 SS 316 (Standard) 2 SS 316L X
GOST Terminal Head Type
F Screwed type, Flameproof Gr. IIA IIB in Die Cast Aluminum
E Screwed type, Explosion proof Gr. IIC in Die Cast Aluminum X
Special Features
3 Terminal head in SS 304 - WP, IP-67
< Mineral insulated cable. 4 Terminal head in SS 316 - WP, IP-67
< Spring loaded design for positive contact with thermowell 5 Terminal head in cast iron, IP-65
< Available in various connections & sheath diameters No of Conduit Entry / Entries
< Sanitary connections are available in size of 1”, 1½”, 2”, 2½”
1 One entry (Standard) 2 Double entry X
< Mounting is very easy & quick
< Enclosures (Head) Conduit Entry Size
Weatherproof IP - 67 A 3/4” ET (Standard) B 1/2” NPT(F) X
< Transmitter output 4 - 20 mA (Optional)
Sanitary Connection Size
< Reference standard : IEC - 751 / DIN 43760.
A 1” B 1½” (Standard) C 2” D 2½” X
Applications
Immersion Length IL - Specify in mm 150 mm
< Sanitary application, food industries etc
Extension Length T - Specify in mm 50 mm
Specifications
Other Options
Standard Version
13 Head mounted transmitter (4-20 mA)
No of element : Simplex 14 SS base plate suitable for temperature transmitter mounting
Element type : Pt - 100 16 1” Clamp with gasket
Range : -200°C till 450°C 17 1½” Clamp with gasket
Accuracy : Class ‘B’ tolerance as per 18 2” Clamp with gasket
IEC - 751 / DIN 43760 19 2½” Clamp with gasket XX
Wire configuration : 3 Wire System 21 Plug for conduit entry in carbon steel
Sheath diameter : 6.0 mm 22 Plug for conduit entry in SS 304
Sheath material : SS 316 23 Plug for conduit entry in SS 316
Terminal head type : Screwed type, Weatherproof, 32 S. C. cable gland in nickel plated brass - WP
Design and specifications subject to change without notice

IP-65 in Die Cast Aluminum 33 D. C. cable gland in nickel plated brass - WP


No. of conduit entry : One 38 S. C. cable gland in nickel plated brass - FLP
Conduit entry size : 3/4" ET(F) 39 D. C. cable gland in nickel plated brass - FLP
Sanitary connection : 1½”, SS 316 40 S. C. cable gland in SS 304 - FLP
Immersion length “Il”mm : 150 mm. 41 D. C. cable gland in SS 304 - FLP
Extension length “T”mm : 50 mm. 42 S. C. cable gland in SS 316 - FLP
Tag plate : Aluminum tag plate 43 D. C. cable gland in SS 316 - FLP
Dimensional Details PW Calibration certificate
SX SS Tag plate
T IL Note :
1. When selecting option “PW”, please also specify temp. points at
which calibration is to be carried out .
2. Explanations of Abbreviations used:
SC = Single Compression SS = Stainless Steel
DC = Double Compression FLP = Flameproof
WP = Weatherproof
31- 08 -12

CL AMP (OPTIONAL) SEALING RING


(OPTIONAL)
Ordering Example :
Notes : • Drawings are not to scale. • All Dimensions are in mm.
R03 . X . X . X . X . XX . X . X . X . X . X . 150mm - 50mm - XX

www.baumer.com Page 1 / 1