Fully Enclosed & Gasketed Industrial: 96 4 L62/830 Hiafr Options DRV UNV

The document provides detailed specifications and ordering information for the Fully Enclosed & Gasketed Industrial LED fixture, including various options for lumen packages, shielding types, and accessories. It highlights features such as moisture resistance, tamper-resistant latches, and certifications for wet locations. The fixture is designed for durability and energy efficiency, with a warranty and multiple mounting options available.

Uploaded by

tonyc
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
50 views3 pages

Fully Enclosed & Gasketed Industrial: 96 4 L62/830 Hiafr Options DRV UNV

The document provides detailed specifications and ordering information for the Fully Enclosed & Gasketed Industrial LED fixture, including various options for lumen packages, shielding types, and accessories. It highlights features such as moisture resistance, tamper-resistant latches, and certifications for wet locations. The fixture is designed for durability and energy efficiency, with a warranty and multiple mounting options available.

Uploaded by

tonyc
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 3

FULLY ENCLOSED & GASKETED INDUSTRIAL

CATALOG #: TYPE:
96
LED
PROJECT: NOTES:

EXAMPLE 96 - 4 - L62/830 - HIAFR - OPTIONS - DRV - UNV


SERIES NOMINAL LUMEN CRI & SHIELDING OPTIONS/ DRIVER VOLTAGE
LENGTH PACKAGE CCT ACCESSORIES

CROSS SECTION
3/8” 3/8”
FEATURES
XXFully gasketed fixture resists dust, bugs,
4-1/8” 5-1/2” and moisture.
XXPolycarbonate toggle latches (standard)
ensure a tight seal and provide easy access
7-3/8” to electrical components.
7-3/8”
XXOptional stainless steel, tamper-resistant
Shown with PCFR
stainless steel, or tamper-resistant
or HIAFR diffuser Shown with polycarbonate latches available.
DCL or DFR diffuser XXClosed-cell polyurethane gasket poured
and formed in place to ensure tight seal–
does not absorb water or support fungal
ORDERING INFORMATION growth.
XXNSF/ANSI Standard 2–Splash Zone
SERIES OPTIONS/ACCESSORIES (Continued) certified.
96 Fully Enclosed & Gasketed Industrial EM/10W 10-watt emergency battery (120-277V only; XXIP65, IP66, and IP67 certified.
not available with L110 or L220 lumen XXRated for -20ºC to 40ºC maximum ambient
NOMINAL LENGTH packages; 4’ or 8’ only) see page 2 for operating temperature (restrictions apply,
2 2’ temperature restrictions see page 2 for details). -40ºC minimum
4 4’ LA40 -40ºC minimum operating temperature operating temperature with LA40 option.
8 8’ (acrylic diffusers only) WET/1 (1) 1/2” watertight hub (factory-installed in end XXMultiple dimming protocols available.
of housing) XXThis fixture is proudly made in the USA.
WET/2 (2) 1/2” watertight hubs (factory-installed
LED PACKAGE in ends of housing; not available with
NOTE: Nominal lumens based on HIAFR shielding. occupancy sensor option)
EXAMPLE: L62/830 SSCMB Stainless steel chain mounting brackets (2 per
fixture)
NOMINAL LUMENS AVERAGE
LUMEN MINIMUM SYSTEM TP Tamper-resistant polycarbonate latches
PACKAGE HIAFR PCFR CRI & CCT WATTAGE (Requires a tamper-resistant tool. Must be
ordered separately. Please specify quantity
2’ required per project.
L21 2,100 1,900 18 SS LATCH Stainless steel latches
L29 2,900 2,600 25 TP/SS LATCH Tamper-resistant stainless steel latches
(Requires a tamper-resistant tool. Must be
4’ ordered separately. Please specify quantity
L40 4,000 3,900 30 required per project.
830 = 82 CRI, 3000K WMB Stainless steel 45º wall mount bracket (2 per
L62 6,400 5,800 48 fixture). See back for details.
835 = 82 CRI, 3500K
L81 8,100 7,400 65
840 = 82 CRI, 4000K OCCUPANCY SENSORS
L110 11,100 10,100 850 = 82 CRI, 5000K 88 Specify from the following options (must specify 120 or 277V;
8’ IP65 certified when specified with occupancy sensor):
L80 8,000 - 61 OCCWS HB350W-L3W
OCCWS FSP-211B-L ­­_ Factory-installed occupancy and
L130 13,000 - 95
daylight control, must specify lens,
L160 16,000 - 123 see page 3 for details. Optional
L220 22,000 - 166 FSIR-100 remote controller available,
ordered separately.
See back for lumen maintenance details. FSIR-100 Remote controller for occupancy
sensor, please specify quantity
SHIELDING required per project, ships separately,
HIAFR Frosted, ribbed, impact-resistant acrylic see page 3 for details
PCFR Frosted, ribbed, UV stabilized polycarbonate (not
available in 8’ units) DRIVER
DFR Drop, frosted, impact-resistant acrylic Additional dimming drivers available, see Technical Info.
DCL Drop, clear, impact-resistant acrylic with frosted DRV Driver prewired for non-dimming applications
ends DIM 10% dimming driver prewired for 0-10V low
voltage applications
OPTIONS/ACCESSORIES
Cord and receptacle options available, see back for details.
(L___) Additional lower lumen packages in 100 nominal VOLTAGE
lumen increments available. Option must be Must specify 120V or 277V when using occupancy sensor.
specified with next higher lumen package. 120 120V
Example: 4,100 nominal lumens =
96-4-L62/840-HIAFR-(L41). 277 277V
UNV 120-277V

H.E. Williams, Inc. Carthage, Missouri w w w.hew.com 417-358-4065 Industrial


Page 1 of 3
96 FULLY ENCLOSED & GASKETED INDUSTRIAL
LED FIXTURE PERFORMANCE DATA
DELIVERED EFFICACY MAXIMUM TEMPERATURE (ºC) CCT MULTIPLIER TABLE
LED PACKAGE WATTAGE
LUMENS (lm/W) STANDARD EMERGENCY SHIELDING CONVERSION FACTOR
SPECIFICATIONS 2’ HIAFR 1.000
Enclosure – Outer housing consists of 5VA L21 2201 18.0 120.5 40 – PCFR 0.913
(f1) fiberglass, rated for flame and weather L29 3028 25.0 118.4 40 – DFR 1.052
resistance. 4’ DCL 1.0621
Internal Housing – .050” aluminum. L40 4086 30.0 137.4 40 40 Due to lens being clear, striations in the
1
Latching – Injection-molded polycarbonate L62 6434 48.0 133.1 40 30 light distribution will be visible.
latches. L81 8121 65.0 125.0 30 25
Reflector – 92% minimum average reflective OO Lumens based on HIAFR shielding.
L110 11075 88.0 126.2 30 – OO Photometrics tested in accordance with
white polyester powder coat bonded to 8’ IESNA LM-79
phosphate-free, multi-stage pretreated metal. OO Results shown are based on 25ºC ambient
L80 8018 61.0 132.8 40 40
Shielding – Frosted, ribbed, impact-resistant temperature and FR shielding
L130 13026 95.0 138.0 40 30
acrylic. OO Wattage shown is average for 120V through 277V

Electrical – High quality mid-power LED L160 16188 123.0 133.3 30 25 input
board. L70 >50,000 hours. -20ºC to 40ºC L220 22056 166.0 135.7 30 – OO Results scaled based on relative CCT output

maximum ambient operating temperature


(restrictions apply, see Performance Data PHOTOMETRY
for details). -40ºC minimum operating
96-4-L62/830-HIAFR-DRV Report #: 20008.0; 08/15/17 | Total Luminaire Output: 6434 lumens; 48.3 Watts
temperature with LA40 option. Efficacy: 133.1 lm/W | 83.6 CRI; 4041K CCT | IES Spacing Criteria: End: 1.1, Across: 1.1, Diagonal: 1.1
Mounting – Surface or suspended. Stainless
180° 160° 140° Vertical Horizontal Angle Zonal
steel ceiling mount brackets included. Zone Lumens % Fixture
Listings – Angle 0º 45º 90º Lumens
OO cETLus conforms to UL STD 1598 and UL 0 2318 2318 2318 0 - 30 1736 27.0

LUMEN SUMMARY
STD 8750. Certified to CAN/CSA STD 5 2352 2298 2283 219.8 0 - 40 2801 43.5
C22.2 No. 250.0. Suitable for dry or damp 15 2259 2169 2120 616.7 0 - 60 4757 73.9
locations. 25 2066 1943 1865 899.3 0 - 90 6156 95.7
OO DesignLights Consortium qualified
120°
35 1780 1666 1704 1065.3 90 - 120 262 4.1
product. Not all versions of this product
CANDLEPOWER DISTRIBUTION
45 1370 1379 1389 1055.1 90 - 150 275 4.3
may be DLC qualified, see the DLC
Qualified Products List at 55 943 1007 1062 900.6 90 - 180 278 4.3
www.designlights.org/QPL. 100° 65 546 695 828 690.8 0 - 180 6434 100.0
OO cETLus listed as suitable for wet 75 231 449 599 456.6
90° 85 38 251 361 251.9
locations when specified with watertight
hub, STOW or SOOW cord, or mini-male 80° 90 15 185 272
receptacle option. 95 14 150 217 143.2
OO NSF/ANSI Standard 2–Splash Zone 105 8 84 138 79.4
certified, IP65, IP66, and IP67 certified, 115 4 39 85 39.0
and rated for NEMA 4X. 60° 125 0 8 42 13.7
Warranty – 5-year limited fixture warranty, 135 0 0 9 1.8
see hew.com/warranty. 145 0 0 2 0.6
155 0 0 0 0.0
165 0 0 0 0.0
IMPORTANT: 0° 20° 40°
175 0 0 0 0.0
180 0 0 0
Electrostatic sensitive unit. Observe precautions 0° 45° 90°
when handling.

FIXTURE DETAILS
CORD OPTIONS BACK VIEW MOUNTING
SSCMB = Stainless steel
EXAMPLE: 5WMRC6 mounting bracket with optional
stainless steel chain hanger
A Stainless steel (field installed)
NUMBER OF POWER CONNECTION CORD ceiling mount
CONDUCTORS – NON-DIMMING LENGTH bracket
(standard)
WMR = Mini-male N/A
receptacle only 3/8”
B
WC = STOW cord Insert screw to make latch
3 = 3-wire tamper-resistant (available
4 = 4-wire WMRC = Mini-male 6 = 6’ Nominal Length Overall Length (A) Mounting Distance (B) in both stainless steel and
receptacle with STOW 20 = 20’ 2’ 27-5/8” 12”- 17” OC
polycarbonate latches)
cord 4’ 51-7/8” 30”- 42” OC
SS LATCH = Stainless
steel latch
POWER CONNECTION 8’ 100-1/4” 48”- 80” OC
– DIMMING WET/1 = (1) 1/2” watertight hub,
factory-installed in end of housing
WMR = Mini-male N/A
receptacle only WMB
5 = 5-wire WC = SOOW cord ø7/16” Keyhole
6 = 6-wire WMRC = Mini-male 6 = 6’
1-1/2” ø1/4”
receptacle with SOOW 20 = 20’
cord
Wet location cord sets are yellow. 5-5/8”

6-1/4”
1-1/4”
Wet location listed with Dry or damp location only
fixture lens facing down with fixture lens facing up

Industrial H.E . W illiams, In c. C ar t hage, Mis s our i w w w.he w.c om 417- 3 5 8 - 4 0 6 5


Page 2 of 3 Information contained herein is subject to change without notice. HEW70467JJ REV.11/06/18
FULLY ENCLOSED & GASKETED INDUSTRIAL 96
LED
OCCUPANCY SENSOR

EXAMPLE OCC WS FSP -211B - L2


t t
OCCUPANCY LENS
SENSOR

XXFully adjustable high and low dimmed light levels. ORDERING INFORMATION
XXDesigned for LED fixtures; rated for extreme temperatures and OCCWS FSP-211B-__ Factory-installed occupancy sensor,
up to 200,000 on/off cycles. must specify lens (120V or 277V only)
XXHold-off setpoint with automatic calibration option for
convenience and added energy savings. LENS
XXAdjustable via handheld wireless configuration tool (ordered L2 Coverage at 8’ mounting height: ø48’
separately, see Accessory Details). L3 Coverage at 20’ mounting height: ø40’
XXIP66 rated with choice of lenses for wet and outdoor locations,
and mounting heights from 8’ to 20’. 0’
XXAdjustable time delay and cutoff delay.
XXFactory set to 10% dimming at 5 minutes, cutoff at 1 hour. 5’
XXMulti-level control based on motion and/or daylight contribution.
10’

0'
15’

8'
24' 11' 7' 3' 0' 3' 7' 11' 24' 20’
20’ 18’ 15’ 12’ 9’ 6’ 3’ 0’ 3’ 6’ 9’ 12’ 15’ 18’ 20’
L2 Lens L3 Lens

ACCESSORY DETAILS
FSIR-100 – Occupancy Sensor Remote

Initial setup and subsequent sensor


adjustments are made using a handheld
configuration tool (FSIR-100). The wireless
tool stores up to five sensor parameter
profiles to speed configuration of multiple
sensors. Please specify quantity required
per project.
Visit www.wattstopper.com for more
information.

H.E. Williams, Inc. Carthage, Missouri w w w.hew.com 417-358-4065 Industrial


Page 3 of 3

You might also like