Conaire Product Catalog 2017
Conaire Product Catalog 2017
TECHNOLOGY
FOR CLIMATE
CONTROL
CLIMATE CONTROL IN MODERN
BUILDINGS TODAY IS NOT JUST ABOUT
TEMPERATURE AND AIR DISTRIBUTION.
IT EXTENDS TO A COMFORTABLE
WORKING ENVIRONMENT THAT
ALSO ENSURES SAFETY, HEALTH AND
PERFORMANCE.
Awarded the best product under Awarded the best product under Awarded the best product under
‘Indoor Air Quality’ category at ‘Indoor Air Quality’ category at “Green Product’ category at Acrex
Acrex 2011. Acrex 2014. 2014.
5
1
CLIMATE
& NOISE CONTROL
A INTELLIGENT CLIMATE
CONTROL
B SUPPLY AIR
OUTLETS
C EXHAUST AIR
INLETS
D CONTROL
DAMPERS
6 7
1 1
CLIMATE CONTROL INTELLIGENT CLIMATE
FOR CENTRALISED AIR CONTROL
CONDITIONING SYSTEMS
In any centrally conditioned environment, health, well-being and CONAIRE offers a number of options for climate control in multiple
performance capability of people are largely dependent on an optimised zones in a system. Each one is a handy compact unit with optional
A
climate. sensors as per requirement. For exmaple in a multiple space demand
controlled application, additional CO2 and VOC sensors can be
Amongst the key factors which influence this optimal climate are indoor
incorporated.
& outdoor air quality.
KEY FEATURES
s It can be integrated with engineered smoke control system.
ADVANTAGES
s It comes with Honey comb patterned airflow straightener which i
drastically reduces the straight length required in ducting
8 9
ZONE REGULATION DEVICES THUMB WHEEL THERMOSTAT
To overcome problem where VAQ station cannot be installed in s Simple & effective climate control with thumb-wheel temperature
situations where it is impossible to provide separate routing of ducts adjustment
zone-wise due to architectural constraints. Automatic Pressure
s Available with carbon dioxide monitor for multiple space demand
Independent Zone Regulation Devices can be installed directly at Supply
control ventilation
Air Outlets or Plenum. Also suitable for fixed occupancy zone, will be
integrated with room vacancy detector to realise energy efficiency by
resetting minimum ventilation during vacancy.
s Various room module thermostat can be integrated for automatic ROOM MODULE (CLIMATE CONTROL)
climate control
s Wire-free, compact unit with flexible mounting for desktop or wall
s Integration with vacancy detector for fixed occupancy zone
s Effective climate control with temperature and humidity sensor
10 11
1
SUPPLY AIR OUTLETS ACCESSORIES
It is the visible end-point in the complex system of supply and exhaust A suitable collar damper is commonly used with these supply air outlets
air where aesthetics obviously play an important role. But couched to regulate the volume of supply air and hence provide effective air
within the aesthetics is the quality of engineering perfection and balancing. It should also integrate fixed or adjustable airflow pattern
B precision that can make or mar the performance of the overall system.
Supply air grilles and diffusers should be properly sized and located to
obtain proper air diffusion and equalise temperature in space.
control for achieving proper discharge pattern.
FEATURES
s With advanced core pulling, spinning and assembly setups, our LOW LEAK ALUMINIUM AIRFOIL OPPOSED
supply air outlets are engineered to perfection BLADE DAMPER
s Available in powder coated/anodised finishes Suitable for manual or reliable motorised airflow regulation at collar.
ADJUSTABLE GRILLES
Come with adjustable vanes to provide multi directional airflow. TURNING VANE DAMPER
Suitable for fine airflow regulation with uniform distribution at collar.
CEILING DIFFUSER
Used in various ceiling systems, mostly to provide horizontal or
vertical airflow discharge pattern with an anti-smudge ring. Available in
rectangular or circular format.
BUTTERFLY DAMPER
Suitable for fine regulation at circular outlets collar.
JET NOZZLE
Used for long distance throw of treated air. They can be rotated for jet
setting.
SOUND ATTENUATOR
Designed for use in rectangular or round ducts to reduce duct borne
noises or breakout noises.
12 13
1 1
EXHAUST AIR INLETS CONTROL DAMPERS
Return and exhaust air is removed from spaces through these inlets Control Dampers are used to cut off or regulate airflow in central air
commonly referred to as return air grilles and diffusers. They are mostly conditioning (heating or cooling) for low to medium pressure. Their
installed without collar dampers. For perfect environment, these should operation can be manual or automatic (pnuematic or electrically
C be properly sized and located and must be selected with least resistance
to air flow and hence minimise air regenerated noise. D operated) depending upon application.
FEATURES
FEATURES s Manufactured with advanced CNC Shearing, Bending Press
s With advanced core pulling, spinning and assembly setup, our
s Experienced work-force with qualified welders ensures our control
exhaust air inlets are engineered to perfection
dampers are engineered to perfection
s Available in powder coated/anodised finishes
s Variety of blade design & construction features to suit your
application
HIGH FLOW LINEAR GRILLES s Various actuator options to chose from, for automatic or manual
control
With or without end-flange. Also available in continuous curvature and
variety of fixing options. s Available in low leakage class, with blade & jamb seal
14 15
ACTUATOR OPTIONS
ABSOLUTE QUADRANT
Used for manual operation of damper having 9 stops locking handle
with thumb trigger and status indicator. The Quadrant should be
accessible for control.
2
INTERNAL KNOB QUADRANT
FIRE & SMOKE
Used for manual operation of damper from inside. Commonly used in
fresh air intake or exhaust applications and return air risers. MANAGEMENT
A ENGINEERED SMOKE
CONTROL SYSTEM
EXTENDED SHAFT
Suited for manual operation of the damper from inside the room,
typically below the ceiling.
B STAIRCASE OR LIFT-WELL
PRESSURISATION
C FIRE
DAMPERS
ELECTRIC ACTUATOR
Available in on/off, floating or modulating configuration with optional
spring return for fail safe automatic operation.
D COMBINATION FIRE
& SMOKE DAMPERS
PNEUMATIC ACTUATOR
Available in on/off with optional spring return for fail safe automatic
operation.
16 17
2 2
FIRE & SMOKE MANAGEMENT IN ENGINEERED SMOKE
CENTRALLY AIR CONDITIONED CONTROL SYSTEM
SYSTEMS
Higher pressures surround the fire area and prevent the spread of
One of the basic requirements of building fire protection as required by smoke from the fire zone to other areas. In this application, the smoke
all building codes is the compartmentation or division of spaces using dampers are motorised with electric or pneumatic actuators.
A
fire rating walls, floors, or other partitioning methods.
They can be controlled by a interconnected damper control modules
This compartmentation is intended to contain any fire to the with connected smoke or a heat detectors, or in a variety of ways by the
compartment of the fire origin and thereby minimise damage to building control system to accomplish the intent of design.
property and protect the lives of people living and/or working in the
building. Smoke detector module, suitable for air velocities upto 2000 fpm and
duct mount option is also available.
Commonly used Smoke Control practices are:
18 19
2 2
STAIRCASE OR LIFT-WELL FIRE DAMPERS
PRESSURISATION
during evacuation to prevent smoke back flow. permit a fire to spread from the compartment of origin to adjoining
B C
compartments.
Multiple slave pressure sensors can be connected in a daisy chain for
tall staircases with multiple injection systems. Fire dampers are installed in these ducts or ventilation openings. Upon
detection of heat, these dampers close (at melting of a UL Stamped
Both bypass damper or VFD control are available as per requirements. fusible link or through a thermal cutoff and solenoid) thus blocking
the opening and preventing the spread of fire into the adjoining
compartments.
20 21
2
D
COMBINATION FIRE SMOKE
DAMPERS
A
with flange of 25mm/40mm. Wall mounted options available with DEMAND CONTROL VENTILATION FOR
an integral sleeve of length 406mm/535mm suitable for 4/9 inches CENTRALISED AIR CONDITIONING
(100mm/225mm).
escape route and ultra fast pressure compensation with modulating fire
smoke damper. Also helps in limiting the pressurisation levels below
door opening forces.
22 23
3 3
DEMAND CONTROL DCV FOR CENTRALISED AIR
VENTILATION (DCV) CONDITIONING
In modern buildings contaminants, toxic gases, and volatile organic VAQ - THE AIRFLOW MONITORING &
compound need to be maintained within the limits. Unmanaged CONTROL STATION
concentrations lead to ‘Sick Building Syndrome’, reduced productivity
A
It is a perfect solution for outdoor air monitoring and at the same
levels of the occupants or even health hazards or illness.
time achieving optimum ventilation. Recommended for green building
Demand Control Ventilation (DCV) effectively helps maintain optimal applications, it is fast becoming an industry standard for various DCV
ventilation while saving energy costs, by monitoring indoor air quality applications.
using carbon dioxide or other contamination sensors from within the
s Accurate airflow through non linear dynamic calibration
breathing zone. It helps in:
s Honeycomb pattern mesh for uniform airflow
s Routine flush out for removal of contamination, which reduces
indoor airborne viruses and bacteria s Can measure airflow even in non-ducted application
s Monitoring of the outdoor air coming into the building s Pressure independent solution for demand control ventilation
s Optimise outdoor air as per multiple space requirement with s Negligible pressure drop and ultra low leak assembly
suitable energy recovery ventilator s Can receive signal from multiple IAQ monitors for multiple space
s Reduce the cost of operating HVAC system with advanced DCV
application specific controller s Wire-free option for hassle free commissioning
HYGIENE LIMITS
Maximum Concentration INDOOR AIR QUALITY MONITOR
Contaminant
Life Safety Health Productivity
s Factory calibrated with most reliable nitrogen calibration technique
Carbon Monoxide (CO) 115 ppm 9 ppm <9 ppm
s Large backlit display, changes colour with changing indoor air
Nitrogen Oxides (NOX) 5 ppm 1 ppm <0.1 ppm
quality
Sulfur Oxides (SOX) 5 ppm 2 ppm <0.25 ppm
Carbon Dioxide (CO2) 5,000 ppm 2000 ppm 600-1000 ppm s Various options available for multi-criteria monitoring
24 25
3 3
DCV IN GUEST ROOMS OR DCV FOR BASEMENT CAR PARK
OFFICE CABINS
A critical area of concern for any hotel is the ventilation and regulation Indoor air quality needs to be monitored constantly in enclosed spaces
of outdoor air in the guest rooms. It is one component of the total with set alarm if the toxic harmful gases exceed the hygiene limits.
HVAC system that has to work optimally at all times.
B C
Mechanical ventilation at all times can be an expensive option.
This also is one area that encounters significant variation in demand on Significant energy savings can be achieved by reducing ventilation rates
day to day basis, simply because of the occupancy levels. Therefore it during low vehicular movement intervals.
becomes more prudent to look at this cost head and find efficient ways
to handle this requirement.
s Reset fresh air to desired minimum ventilation rate, adjustable to s Integrated with more reliable CO2 sensor to check for other
as low as 15 cfm harmful gases
s VAQ station can be installed at DOAS supply/return air, that can s Advanced application controller with plug and play operation for
regulate airflow and fan speed based on occupied zones and easy site installations
general area requirements s Manual override option to provide maximum ventilation during
s At an occupancy level of 40% the energy costs can be reduced by predetermined peak loads
as much as 45% s Smoke over-ride option for maximum ventilation upon receiving
signal from smoke detectors or central fire alarm panel.
s Smoke duty rated for 300O C for 2 hours. Jet Fan for ductless
ventilation. Dual speed suitable for normal and smoke duty
DEDICATED OUTDOOR AIR SYSTEM application
26 27
3 3
DCV WITH ENERGY RECOVERY BUILDING INTAKE & EXHAUST
FOR SMALL FACILITIES
For installations without a centralised air conditioning system, the Demand control ventilation can be effective only if building intake &
requirement of fresh air for comfort and performance cannot be exhaust is properly designed and selected. This can be achieved by
ignored. Therefore a small energy recovery unit combined with an installing application specific architectural louvers, that allow air to pass
Key factors in the selection of louvers are the free area, water
demand control ventilation. penetration, and resistance to airflow. Other performance features are
sand protection, sound absorption, back-draft damper for restricting
air flow in one direction. Some of the special purpose louvers and back
SINGLE ROOM ENERGY RECOVERY draft dampers for building intake & exhaust openings are:
VENTILATOR
s Highly efficient energy recovery module
DRAINABLE LOUVER
s Easy to install
Incorporates drainable head member and fixed horizontal louvers to
s Suitable for single room installed with split unit
channel water towards jambs which guide the water through vertical
s Saves energy downspout for escape at the sill.
ADJUSTABLE LOUVER
Suitable for application where high free area is required. The amount of
free area can be acheived by adjusting the louvers.
ENERGY RECOVERY UNIT
s Suitable for apartments, small offices, hotels or retail, installed
with VRV, or ducted units
ACOUSTIC LOUVER
Designed for sound absorption from spaces with equipment or process
generated noise.
28 29
COMBINATION OF LOUVER & GRAVITY
BACK-DRAFT DAMPER
Features front stationary drainable louver and secondary gravity
exhaust/ intake back-draft damper. Suitable for mounting on exterior
wall openings.
4
COMBINATION OF LOUVER &
ADJUSTABLE DAMPER
CONTAMINATION
Features front stationary drainable louver and secondary operable
damper. Suitable for mounting on exterior walls for fresh air intake, as
& PROCESS CONTROL
a single unit.
A COMPREHENSIVE
AIR QUALITY CHECK
C CONTAMINATION &
CORROSION CONTROL
D
less pressure. These damper consist of multiple heavy gauge extruded DISPLACEMENT FLOW
aluminium blades in C type deep extruded aluminium frame having duct TERMINAL PRODUCTS
suitable flange of 25 mm.
30 31
4
CONTAMINATION & PROCESS
CONTROL
s Facilitate sterile compounding in pharmacy s Control dampers are used for flow control in extreme pressure and
velocity systems. Dampers having better flow characteristics and
s Maintain product quality for clean manufacturing
control options are recommended for this application
s Prevent corrosion and maintain copper and silver reactivity levels
s Pressure relief dampers are used for pressurisation systems,
Key requirement is to establish the hygiene limit on the basis of Indoor gas fire extinguishing systems, internal spaces with explosive
Air Quality - Climate & pollutants within the space contamination, atmospheres or transformer substations
noxious gases and pollutants in the ambient air and then, optimised
Such dampers require performance and integration testing, our in-
ventilation for proper IAQ & contamination.
house air performance testing facility as per AMCA enables us to design
Achieve desired air movement for balanced air distribution & mixing. and test dampers for any challenging process control application.
32 33
4
COMPREHENSIVE ROOM MODULE (FLOW)
AIR QUALITY CHECK s Air movement monitoring using portable flow sensor, calibrated
for log - Tchebycheff like rapid average pitot tube flow
Comprehensive air quality check includes Transient contamination
measurements
analysis using advanced multi zone airflow modelling techniques
and its validation using application specific mesh of portable Neural s Flexible mounting on duct, air outlets or supply air collars
sensors in terms of:
A
s User friendly software for remote monitoring and analytics
Ambient Air Quality - Noxious gases and pollutants in the ambient
air or generated nearby as per NAAQs, using wind pressure and
contaminant data (WPC) based on site location, an initial building
model is prepared. ROOM MODULE (PARTICLE)
Infiltration and Exfiltration - Unwanted leakages for zone to zone s Accurate particle monitoring
air transfer are added into building model using ASHRAE effective
s User friendly software for remote monitoring and analytics
leakages table
s Complies with ANSI/ASHRAE/ASHE Standard 170-2008,
Room Air Movement - for balanced air distribution & mixing, building
Ventilation of Health Care Facilities
air distribution for calculating air change effectiveness and proper air
distribution is simulated.
Contamination Control- Based on hygiene limit level, The s Easy configuration via local programming on display Passwords
contamination report is presented with suggested measures and prevent unauthorised access to monitor functions
modification
Complies with ANSI/ASHRAE/ASHE Standard 170-2008, Ventilation of
Health Care Facilities
s Accurate airflow through non linear dynamic calibration s Measures corrosivity, target gases in lowest resolution suitable for
any application in real-time
s Negligible pressure drop and ultra low leak assembly
s Vital for protecting valuable electronic and other equipment
s Honeycomb pattern mesh for uniform Airflow
s Easily replaceable sensor heads
s Communicates with lab management system
s User friendly software with remote monitoring and analytics
Control system, also available for use in potential explosive
atmosphere zone 1, 2, 21, 22 s Sensors easily replaceable
34 35
4
CONTAMINATION & Differential Pressure Sensing Control Method: maintained by
adjusting total amount of air exhausted from and supplying constant
CORROSION CONTROL airflow to the room or space or vice versa. Suitable for constant
volume system. Slower than flow tracking, response in ~15 seconds.
Different applications require different degrees of air cleaning
Cascade Control Method: uses both the above techniques best but
effectiveness. In industrial applications, removing only the larger dust
complex and costly to implement.
particles from the airstream may be necessary for cleanliness of the
CONTAMINATION CONTROL UNIT s Maintains climate and particulate contamination within desired
range
s Air handler suited for pressurisation features make up air
s Suitable for pressurisation of data centres and server rooms
s Factory tested for performance and automation
s Includes ultra fast lab management, VAQ-LMS with room pressure
s Remote monitoring and analytics package
and continuous corrosivity monitor
s Incorporated with smoke extraction features
36 37
4
DISPLACEMENT FLOW
TERMINAL PRODUCTS
Displacement flow, is the piston or plug type unidirectional motion,
desirable for removing pollutants generated within the space. Laminar DISPLACEMENT DIFFUSER
flow diffuser, sweeping air across a space produces displacement
flow. Suitable for installation in critical areas such as clean room or Displacement flow diffusers discharge the air with a low velocity and
C operating room.
s Designed for use in clean rooms, laboratories, operating theatres s Rectangular duct connection
s Volume control damper for either front adjustable or back UNDER-FLOOR DIFFUSERS
adjustable for walkable ceiling
Suitable for office spaces to support convection currents caused by
people, machines or electrical devices. They can be deployed at a
distance of 40 cm from seating.
38 39
4
PROCESS CONTROL ACTUATOR OPTIONS
Industrial dampers are required in process control to divert hot
Heavy duty actuators for manual or automatic operation, rated for
exhaust from gas turbine exhaust to recovery boiler, or to shut off
torque upto 300 NM. Options available for every industrial stringent
process for maintenance, or to regulate gas or airflow in process
requirements.
control. Its operation can be manual or motorised.
3V DAMPER
40 41
PRESSURE RELIEF DAMPER
HYDROGEN SENSOR
For Electrical Safety in the workplace, building owners can find PRODUCT QUERIES
requirements for safely designing a battery charging room. This
requires a ventilation system to exhaust air from the room to the
For further details or to call for a meeting on any of the products listed
outdoors. Since hydrogen gas is lighter than air in the room, it
in the catalog, please contact:
should be exhausted from an adequate height in the room. When its
concentration rises to level above 4% there is a substantial risk of sales@conaire.in
explosion. +91 7042932450
s Explosive gases such as hydrogen in battery charging should be
limited to 1000 ppm for prevention of explosion.
s Complies with the requirement of article 320 of NFPA 70E TECHNICAL QUERIES
s Accurate Hydrogen sensor measuring range of 1000 ppm
engineering@conaire.in
+91 9310048450
SERVICE QUERIES
support@conaire.in
+91 9911243399
42 43