HVAC COMMENTS
The air grille extends through to the outside of the
wall.(ATTACH 01)
Missing return air grill and supply air grill need to be
exposed to the wall(ATTACH 02)
FCU inside the wall (ATTACH 03)
FCU inside the wall (ATTACH 04)
Return air grill inside the wall & need to be exposed
to the wall(ATTACH 05)
Some FCU output need to adjust in family and then
connected to the duct and add canvas(ATTACH 06)
FF COMMENTS
FHC need to be aligned to wall inlet surface (ATTACH
07)
Some sprinklers need to coordinated with ID (ATTACH
08)
Recheck the pipe fitting types (ATTACH 09)
WS COMMENTS
Pipes type need to redifine (ATTACH 10)
View range of floor need to adjust(undertiles pipes of
level 02 doesn’t exist and undertiles pipes of level 03
exist in level 02
hot and cold inlet of lavatory swaped(ATTACH 11)
pipes inlets should be at plumbing fixture(ATTACH 12)
DR COMMENTS
Check elevation of AC drainage pipes inside
suites(ATTACH 13)
Follow the ID & IFC location(ATTACH 14)
In all suites soil pipe exposed(ATTACH 15)
Check the pipes fittings that conflict with wall(ATTACH
16)
LOCATION
SPECIAL JUNIOR SUITE-K TYPE B (AXES 02:03)
ELEC. ROOM (AXES 02:03)
ONE BEDROOM SUITE-K (AXES 16:17)
JUNIOR SUITE TYPE A-K(EXTENDED) (AXES 18:19)
IT ROOM(AXES 17:18)