Brosur LBS74723
Brosur LBS74723
R4E280-AD08-13
Operating instructions
1.4 Voltage
; Check the device's electrical equipment at regular intervals; see
Chapter 5.2 Safety inspection.
; Replace loose connections and defective cables immediately.
DANGER
Electrically charged device
Risk of electric shock
→ When working on an electrically charged device, stand on a
rubber mat.
ebm-papst Mulfingen GmbH & Co. KG · Bachmühle 2 · D-74673 Mulfingen · Phone +49 (0) 7938 81-0 · Fax +49 (0) 7938 81-110 · info1@de.ebmpapst.com · www.ebmpapst.com
R4E280-AD08-13
Operating instructions
DANGER
; We recommend storing the device for no longer than one year in
Rotating device
order to guarantee trouble-free operation and the longest possible
Risk of injury to body parts coming into contact with the rotor or
service life.
the impeller.
; Even devices explicitly intended for outdoor use are to be stored as
→ Secure the device against accidental contact.
described prior to commissioning.
→ Before working on the system/machine, wait until all
; Maintain the storage temperature, see
parts have come to a standstill.
Chapter 3.5 Transport and storage conditions.
WARNING
Rotating device
Long hair and dangling items of clothing, jewelry and the like
can become entangled and be pulled into the device. Injuries
can result.
→ Do not wear any loose-fitting or dangling clothing or jewelry
while working on rotating parts.
→ Protect long hair with a cap.
ebm-papst Mulfingen GmbH & Co. KG · Bachmühle 2 · D-74673 Mulfingen · Phone +49 (0) 7938 81-0 · Fax +49 (0) 7938 81-110 · info1@de.ebmpapst.com · www.ebmpapst.com
R4E280-AD08-13
Operating instructions
2. INTENDED USE
The device is exclusively designed as a built-in device for conveying
air according to its technical data.
Any other usage above and beyond this does not conform with the
intended purpose and constitutes misuse of the device.
Customer equipment must be capable of withstanding the mechanical
and thermal stresses that can arise from this product. This applies for the
entire service life of the equipment in which this product is installed.
Intended use also includes
● Conveying air at an ambient air pressure between 800 mbar and
1050 mbar.
● Using the device within the permitted ambient temperature range; see
Chapter 3.5 Transport and storage conditions and
Chapter 3.2 Nominal data.
● Operating the device with all protective devices.
● Following the operating instructions.
Improper use
In particular, operating the device in the following ways is prohibited and
could be hazardous:
● Operating the device in an unbalanced state, e.g. due to dirt deposits
or ice formation.
● Resonant operation, operation with severe vibration. This also
includes vibration transmitted to the fan from the customer installation.
● Operation in medical equipment with a life-sustaining or life-support
function.
● Conveying solids in the flow medium.
● Painting the device
● Connections (e.g. screws) coming loose during operation.
● Conveying air that contains abrasive particles.
● Conveying highly corrosive air, e.g. salt spray. Exception: devices
designed for salt spray and correspondingly protected.
● Conveying air with high dust content, e.g. suctioning off sawdust.
● Operating the device close to flammable materials or components.
● Operating the device in an explosive atmosphere.
● Using the device as a safety component or to perform safety-related
functions.
Translation of the original operating instructions
ebm-papst Mulfingen GmbH & Co. KG · Bachmühle 2 · D-74673 Mulfingen · Phone +49 (0) 7938 81-0 · Fax +49 (0) 7938 81-110 · info1@de.ebmpapst.com · www.ebmpapst.com
R4E280-AD08-13
Operating instructions
3. TECHNICAL DATA
ebm-papst Mulfingen GmbH & Co. KG · Bachmühle 2 · D-74673 Mulfingen · Phone +49 (0) 7938 81-0 · Fax +49 (0) 7938 81-110 · info1@de.ebmpapst.com · www.ebmpapst.com
R4E280-AD08-13
Operating instructions
ebm-papst Mulfingen GmbH & Co. KG · Bachmühle 2 · D-74673 Mulfingen · Phone +49 (0) 7938 81-0 · Fax +49 (0) 7938 81-110 · info1@de.ebmpapst.com · www.ebmpapst.com
R4E280-AD08-13
Operating instructions
3.2 Nominal data With regard to cyclic speed loads, note that the rotating parts of
the device are designed for a maximum of one million load
Motor M4E068-DF cycles. If you have special questions, consult ebm-papst for
support.
Phase 1~ 1~ 1~
Nominal voltage / VAC 230 230 230 ; Use the device in accordance with its degree of protection.
Frequency / Hz 50 60 60 Information on surface quality
Method of obtaining fa fa fa The surfaces of the products conform to the generally applicable industrial
data standard. The surface quality may change during the production period.
Valid for approval/ CE CE UL 1004-3 This has no effect on strength, dimensional stability and dimensional
standard accuracy.
Speed (rpm) / min-1 1420 1635 1635 The color pigments in the paints used perceptibly react to UV light over
Power consumption / W 78 105 115 the course of time. This does not however in any way affect the
Current draw / A 0.35 0.42 0.49 technical properties of the products. The product is to be protected against
Capacitor / µF 2.5 2.5 2.5 UV radiation to prevent the formation of patches and fading. Changes in
color are not a reason for complaint and are not covered by the warranty.
Capacitor voltage / VDB 450 400 400
Capacitor standard S0 (CE) S0 (CE) UL 3.4 Mounting data
Min. back pressure / Pa 0 0 0
Min. ambient -25 -25 -25 Any further mounting data required can be taken from the product
temperature / °C drawing or Section Chapter 4.1 Mechanical connection.
Max. ambient 40 40 40 Strength class of 8.8
temperature / °C screws
ml = Max. load · me = Max. efficiency · fa = Free air
cs = Customer specification · ce = Customer equipment
For screw clearance, see Chapter 3.1 Product drawing
Subject to change ; Secure the screws against unintentional loosening (e.g. use self-
locking screws).
3.3 Technical description
3.5 Transport and storage conditions
Weight 2.9 kg
Size 280 mm Max. permitted +80 °C
Motor size 68 ambient temp. for
Rotor surface Painted black motor (transport/
storage)
Impeller material Sheet steel, painted black
Min. permitted -40 °C
Number of blades 11
ambient temp. for
Direction of rotation Clockwise, viewed toward rotor
motor (transport/
Degree of protection IP44; installation- and position-dependent
storage)
as per EN 60034-5
Insulation class "B"
Moisture (F) / H1
Environmental (H)
protection class
Installation position Shaft horizontal or rotor on bottom; rotor
Translation of the original operating instructions
on top on request
Condensation On rotor side
drainage holes
Mode S1
Motor bearing Ball bearing
Touch current < 0.75 mA
according to IEC
60990 (measuring
circuit Fig. 4, TN
system)
Motor protection Thermal overload protector (TOP)
internally connected
with cable Variable
Protection class I (with customer connection of protective
earth)
Conformity with EN 60034-1; EN 60204-1; EN 60335-1;
standards CE
Approval CSA C22.2 No. 77; UL 1004-3
ebm-papst Mulfingen GmbH & Co. KG · Bachmühle 2 · D-74673 Mulfingen · Phone +49 (0) 7938 81-0 · Fax +49 (0) 7938 81-110 · info1@de.ebmpapst.com · www.ebmpapst.com
R4E280-AD08-13
Operating instructions
ebm-papst Mulfingen GmbH & Co. KG · Bachmühle 2 · D-74673 Mulfingen · Phone +49 (0) 7938 81-0 · Fax +49 (0) 7938 81-110 · info1@de.ebmpapst.com · www.ebmpapst.com
R4E280-AD08-13
Operating instructions
ebm-papst Mulfingen GmbH & Co. KG · Bachmühle 2 · D-74673 Mulfingen · Phone +49 (0) 7938 81-0 · Fax +49 (0) 7938 81-110 · info1@de.ebmpapst.com · www.ebmpapst.com
R4E280-AD08-13
Operating instructions
U1 blue
Z brown
U2 black
PE green/yellow
Translation of the original operating instructions
ebm-papst Mulfingen GmbH & Co. KG · Bachmühle 2 · D-74673 Mulfingen · Phone +49 (0) 7938 81-0 · Fax +49 (0) 7938 81-110 · info1@de.ebmpapst.com · www.ebmpapst.com
R4E280-AD08-13
Operating instructions
ebm-papst Mulfingen GmbH & Co. KG · Bachmühle 2 · D-74673 Mulfingen · Phone +49 (0) 7938 81-0 · Fax +49 (0) 7938 81-110 · info1@de.ebmpapst.com · www.ebmpapst.com
R4E280-AD08-13
Operating instructions
In the event of further malfunctions, contact ebm-papst. Fastening the Visual inspection At least every Fasten
cables 6 months
Fastening the Visual inspection At least every Fasten
protective earth 6 months
5.1 Cleaning
terminal
To ensure a long service life, check the fans regularly for proper Insulation of Visual inspection At least every Replace cables
operation and soiling. The frequency of checking is to be adapted cables for 6 months
accordingly depending on the degree of soiling. damage
DANGER Impeller for Visual inspection At least every Clean impeller
Risk of injury from rotating fan. wear/deposits/ 6 months or replace device
corrosion and
→ Only clean when not in motion. Interrupt the power supply,
damage
secure against renewed switch-on. Secure against start-up,
Condensation Visual inspection At least every Open holes
prevent air flow.
drainage holes 6 months
; Dirt deposits on the motor housing can cause overheating of the motor. for clogging,
; Soiling of the impeller can cause vibration that will shorten the service where necessary
life of the fan. Abnormal acoustic At least every Replace device
; Severe vibration can destroy the fan. bearing noise 6 months
; In such cases, switch off the fan immediately and clean it. Vibration test Vibration tester, Recommended Clean impeller
start-up or every 6 months or replace device
; The preferred method of cleaning is dry cleaning, e.g. using deceleration
compressed air. measurement
; Do not use aggressive cleaning agents!
NOTE 5.3 Disposal
Damage to the device during cleaning For ebm-papst, environmental protection and resource preservation are
Malfunction possible top priority corporate goals.
→ Do not clean the device using a water jet or high-pressure ebm-papst operates an environmental management system which is
cleaner. certified in accordance with ISO 14001 and rigorously implemented
→ Do not use any acid, alkali or solvent-basedcleaning around the world on the basis of German standards.
agents. Right from the development stage, ecological design, technical safety
and health protection are fixed criteria.
→ Do not use any pointed or sharp-edged objects for cleaning
The following section contains recommendations for ecological disposal
; Completely remove any cleaning agents used. of the product and its components.
; If severe corrosion is visible on load-bearing or rotating parts, switch 5.3.1 Country-specific legal requirements
off the device immediately and replace it.
; Repair of load-bearing or rotating parts is not permitted! NOTE
Country-specific legal requirements
; Operate the fan for 2 hours at maximum speed so that any water that
Always observe the applicable country-specific legal
has ingressed can evaporate.
regulations with regard to the disposal of products or waste
; If cleaning does not eliminate vibrations, the fan may need to be occurring in the various phases of the life cycle. The
rebalanced. To have it rebalanced, contact ebm-papst. corresponding disposal standards are also to be heeded.
; The fan is equipped with maintenance-free ball bearings. The lifetime
Translation of the original operating instructions
lubrication of the ball bearings is designed for a service life of 40,000 5.3.2 Disassembly
hours. Disassembly of the product must be performed or supervised by
; If bearing replacement is necessary after that period, contact ebm- qualified personnel with the appropriate technical knowledge.
papst. The product is to be disassembled into suitable components for disposal
; Adapt the maintenance intervals to the actual level of dust exposure. employing standard procedures for motors.
WARNING
5.2 Safety inspection Heavy parts of the product may drop off. Some of the
What to check How to check How often What action? product components are heavy. These components
could drop off during disassembly.
Contact Visual inspection At least every Repair or
This can result in fatal or serious injury and material damage.
protection 6 months replacement of
cover for device → Secure components before unfastening to stop them falling.
intactness or
damage
Device for Visual inspection At least every Replacement of
damage to 6 months device
blades and
housing
ebm-papst Mulfingen GmbH & Co. KG · Bachmühle 2 · D-74673 Mulfingen · Phone +49 (0) 7938 81-0 · Fax +49 (0) 7938 81-110 · info1@de.ebmpapst.com · www.ebmpapst.com
R4E280-AD08-13
Operating instructions
ebm-papst Mulfingen GmbH & Co. KG · Bachmühle 2 · D-74673 Mulfingen · Phone +49 (0) 7938 81-0 · Fax +49 (0) 7938 81-110 · info1@de.ebmpapst.com · www.ebmpapst.com
ITEM 2
Nominal data
Type R2E220-AB06-67
Motor M2E068-CF
Phase 1~ 1~
Nominal voltage VAC 230 230
Frequency Hz 50 60
ebm-papst Mulfingen GmbH & Co. KG · Bachmühle 2 · D-74673 Mulfingen · Phone +49 (0) 7938 81-0 · Fax +49 (0) 7938 81-110 · info1@de.ebmpapst.com · www.ebmpapst.com
R2E220-AB06-67 AC centrifugal fan
backward-curved, single-intake
Technical description
Weight 1.86 kg
Size 220 mm
Motor size 68
Rotor surface Painted black
Impeller material PA plastic, sheet-metal plate painted black
Number of blades 11
Direction of rotation Clockwise, viewed toward rotor
Degree of protection IP54
Insulation class "B"
Moisture (F) / Environmental (H) H2+
protection class
Max. permitted ambient temp. +80 °C
for motor (transport/storage)
Min. permitted ambient temp. for -40 °C
motor (transport/storage)
Installation position Shaft horizontal or rotor on bottom; rotor on top on request
Condensation drainage holes On rotor side
Mode S1
Motor bearing Ball bearing; (sealed, without air gap)
Touch current according to IEC < 0.75 mA
60990 (measuring circuit Fig. 4,
TN system)
Motor protection Thermal overload protector (TOP) internally connected
With cable Variable
Protection class assignment I; If a protective earth is connected by the customer
This component for installation may have several local protection classes. This
information relates to this component’s basic design.
The final protection class is based on the component’s intended installation and
connection.
Conformity with standards EN 60034-1; EN 60204-1; EN 60335-1; CE
Approval CSA C22.2 No. 100; UL 1004-1
ebm-papst Mulfingen GmbH & Co. KG · Bachmühle 2 · D-74673 Mulfingen · Phone +49 (0) 7938 81-0 · Fax +49 (0) 7938 81-110 · info1@de.ebmpapst.com · www.ebmpapst.com
R2E220-AB06-67 AC centrifugal fan
backward-curved, single-intake
Product drawing
ebm-papst Mulfingen GmbH & Co. KG · Bachmühle 2 · D-74673 Mulfingen · Phone +49 (0) 7938 81-0 · Fax +49 (0) 7938 81-110 · info1@de.ebmpapst.com · www.ebmpapst.com
R2E220-AB06-67 AC centrifugal fan
backward-curved, single-intake
Accessory part
Connection diagram
ebm-papst Mulfingen GmbH & Co. KG · Bachmühle 2 · D-74673 Mulfingen · Phone +49 (0) 7938 81-0 · Fax +49 (0) 7938 81-110 · info1@de.ebmpapst.com · www.ebmpapst.com
R2E220-AB06-67 AC centrifugal fan
backward-curved, single-intake
350
1.4
ρ = 1.185 kg/m³ ± 2 %
Measurement: LU-106769-1
300 4
1.2
150
0.6
2
100
0.4
50
0.2
1
pfs
Measured values
Wired U f n Pe I qV pfs qV pfs
V Hz min-1 W A m3/h Pa cfm in. wg
1 1~ 230 50 2700 85 0.38 920 0 540 0.00
2 1~ 230 50 2540 97 0.43 720 125 425 0.50
3 1~ 230 50 2475 104 0.46 525 225 310 0.90
4 1~ 230 50 2500 101 0.45 330 300 195 1.20
Wired = Wiring · U = Voltage · f = Frequency · n = Speed (rpm) · Pe = Power consumption · I = Current draw · qV = Air flow · pfs = Pressure increase
ebm-papst Mulfingen GmbH & Co. KG · Bachmühle 2 · D-74673 Mulfingen · Phone +49 (0) 7938 81-0 · Fax +49 (0) 7938 81-110 · info1@de.ebmpapst.com · www.ebmpapst.com
R2E220-AB06-67 AC centrifugal fan
backward-curved, single-intake
500
2
ρ = 1.185 kg/m³ ± 2 %
1.8
Measurement: LU-106770-1
200
0.8
0.6
2
100
0.4
0.2
1 cfm
pfs
Measured values
Wired U f n Pe I qV pfs qV pfs
V Hz min-1 W A m3/h Pa cfm in. wg
1 1~ 230 60 3050 115 0.51 1030 0 605 0.00
2 1~ 230 60 2765 128 0.56 810 125 475 0.50
3 1~ 230 60 2595 138 0.60 550 250 325 1.00
4 1~ 230 60 2690 133 0.58 325 350 190 1.41
Wired = Wiring · U = Voltage · f = Frequency · n = Speed (rpm) · Pe = Power consumption · I = Current draw · qV = Air flow · pfs = Pressure increase
ebm-papst Mulfingen GmbH & Co. KG · Bachmühle 2 · D-74673 Mulfingen · Phone +49 (0) 7938 81-0 · Fax +49 (0) 7938 81-110 · info1@de.ebmpapst.com · www.ebmpapst.com