MINI Wiring Guide V1.00
MINI Wiring Guide V1.00
EP.MINI
Version 1.00 Last Updated: 19-05-2009
1
Model: EP.MINI
Note:
See http://www.entrypass.net/ for updates, revisions, and download the latest installation manual
There are currently 2 version of EntryPass Platform1 Access Control System available for different card
number system
1) EntryPass Platform1 Access Control System (6 Digit Card Number System) cater for 6 digit card
number installation
2)EntryPass Platform1 Access Control System (10 Digit Card Number System) cater for 10 digit card
number installation
For EntryPass Platform1 Access Control System to work correctly, both control panel and software MUST
be using the same card number system
This software installation manual might be updated without prior notice
Please refer to separate EntryPass Platform1 User Manual for detail operation help. The Official
EntryPass Platform1 User Manual can be downloaded from our website under “Download” section
2
Model: EP.MINI
Before you begin
Technical Support
If you cannot find the answer to your question in this manual or in the Help files, we recommend you
contact your system installer. Your installer is familiar with your system configuration and should be able
to answer any of your questions.
Should you need additional information, please call our Technical Support Help desk, Monday to Friday
9:00 AM to 6:00 PM (GMT +8:00)
Method Details
Phone + 60 (3) - 8068 1929
Fax + 60 (3) - 8068 1922
Internet www.entrypass.net
Email support@entrypass.net
3
Model: EP.MINI
Considerations Prior to Installation
EntryPass controller contains numerous delicate electronic circuits and components which can become damaged
as a result of electrostatic discharge (ESD). Thus, prior to installation, please follow the instruction below:
•Observe precautions while handling the circuit board assembly by using proper grounding straps and handling
precautions at all
•Visually ensure no onboard parts is broken, damage or contains burn mark
•Do not turn on the power supply until you completed all wiring and external add on devices installations
CAUTION
Battery may explode if mistreated. Do not recharge, disassemble
or dispose of in fire. To prevent a risk of explosion do not pry the
battery out with a metal or conductive tool.
Instances of Non-Warranty
•Damage due to natural disaster, accident or human cause.
•Damage as a result of violating the conditions recommended in the user manual
•Damage due to improper installation
•Damage due to use of uncertified components
•Damage due to use exceeding the permitted parameters
4
Model: EP.MINI
MiNi Description
5
Model: EP.MINI
MiNi Color Description
6
Model: EP.MINI
MiNi reader keypad display unit
Enter Key
7
Model: EP.MINI
Power Supply Unit Specification
ENTRYPASS
8
Model: EP.MINI
Connecting MINI to ELC
Switching Mode
Power Supply Unit
(12V DC, 3A Minimum)
0V +12 VDC
The distance from MINI keypad reader to ELC should not more than 10 meter
9
Model: EP.MINI
Connecting the Lock (NC), Breakglass and Keyswitch to ELC
Switching Mode
Power Supply Unit
(12V DC, 3A Minimum)
0V
White/Blue (CM1)
White (NC1)
Purple (+12VDC)
Emergency Purple (+12VDC)
Breakglass
Emergency
Keyswitch
+ -
- +
Electro-Magnetic Lock
Diode(1N4002) must be installed at the locking devices in order to protect against back EMF
10
Model: EP.MINI
Connecting the Lock (NO)
Switching Mode
Power Supply Unit
(12V DC, 3A Minimum)
0V
White/Blue (CM1)
Grey/Yellow (NO1)
Purple (+12VDC)
Purple (+12VDC)
+ -
- +
Diode(1N4002) must be installed at the locking devices in order to protect against back EMF
11
Model: EP.MINI
Connecting the Door Sensor and Door Release Button/Push Button
The distance from door sensor to MINI and from push button to ELC should not more than 30 meter
12
Model: EP.MINI
Connecting the Exit Reader – MINI reader as an exit reader
To configure MINI as a
READER Mode, press:
Switching Mode
Power Supply Unit •F1
(12V DC, 3A Minimum) •123456
•01 Enter
0V +12 VDC •01 Enter
•05 Enter
•1 Enter
•ESC x3
Black (Gnd) Black (Gnd)
Red (+12VDC) Red (+12VDC)
Green (D0) Orange (RCLK) To configure NMINI as a
White (D1) Yellow (RDAT) READER Mode, press:
•F1
•123456
•01 Enter
•01 Enter
Exit Reader
•04 Enter
•1 Enter
•ESC x3
To use MINI/NMINI on exit reader side, you must enable the READER MODE function on the
programming mode
13
Model: EP.MINI
Connecting the Exit Reader – 3rd Party Reader
Switching Mode
Power Supply Unit
(12V DC, 3A Minimum)
0V +12 VDC
Exit Reader
The distance from MINI to exit reader should not more than 10 meter
14
Model: EP.MINI
Configuring the MINI Unit Address
15
Model: EP.MINI
Connecting to the PC using RS 232 mode
DB 9 Female Connecter
EntryPass Platform1
Server Access
Control System
The distance from computer to MINI should not more than 10 meter
16
Model: EP.MINI
Connecting to the PC using RS 485 mode
C-
RS232
Power
RS 232: 10 meter C+
Rx
Tx
PCC
EntryPass Platform1 (Pc Communicator)
Server Access
Control System
17
Model: EP.MINI
Connecting to the power supply unit
Switching Mode
Power Supply Unit
(12V DC, 3A Minimum)
0V +12 VDC
Red/Yellow (+12VDC)
Black (Gnd)
18
Model: EP.MINI
Complete overview
Switching Mode
Power Supply Unit
(12V DC, 3A Minimum)
0V +12 VDC
Red/Yellow (+12VDC)
Black (Gnd) Black (Gnd)
Orange (RCLK) Orange (RCLK)
Yellow (RDAT) Yellow (RDAT)
Blue (RTX) Blue (RTX)
Red (+12VDC) Pink (Push Button)
Green (D0) Red (+12VDC)
White (D1) Black (Gnd)
Black (Gnd) White/Blue (CM1)
Pink (Door Sensor) White (NC1)
Purple (+12VDC)
Grey (C+)
Purple (C-) Emergency
Breakglass
Emergency
Keyswitch
Push
Door Button
Sensor + -
C-
Exit
RS232
C+ - +
Power
Reader
Rx
Tx
19
Model: EP.MINI
Before connecting to the EntryPass Platform1 Access Control System
Before you begin to connect to the EntryPass Platform1 Access Control System, please make sure
all the wiring connection is correct. On the MINI keypad, please make sure the following setting
has been done:
Format Memory
Unit Address
To configure the
Advisable to EP.MINI unit address
perform format if there is more than
memory for the one MINI controller
first time you turn connected to the PC
on the power communicator
20
Model: EP.MINI
MINI (6 digit firmware) Programming Mode
To enter programming mode, press:
•F1
•123456 (default admin pin)
Admin Pin Inhibit Mode Door Pin 1
•Enter programming mode •Enter programming mode •Enter programming mode
•01 Enter •01 Enter •01 Enter
•01 Enter •02 Enter •02 Enter
•01 Enter •01 Enter •06 Enter
•Key in new admin pin (6 digits) •1 Enter (Press 1 to set it ON or press 0 to set it OFF) •Key in the new door pin (6 digits)
•ESC X3 •ESC X3 •09 Enter
•01
Normal Pin Security Mode •ESC X3
•Enter programming style •Enter programming mode
•01 Enter •01 Enter Door Pin 2
•01 Enter •02 Enter •Enter programming mode
•02 Enter •02 Enter •01 Enter
•Key in new normal pin (6 digits) •0 Enter (Press 1 to set it ON or press 0 to set it OFF) •02 Enter
•ESC X3 •ESC X3 •07 Enter
•Key in the new door pin (6 digits)
Security Level Site Code 1 •10 Enter
•Enter programming mode •Enter programming mode •01
•01 Enter •01 Enter •ESC X3
•01 Enter •02 Enter
•03 Enter •03 Enter Door Pin 3
•1 Enter (Press 1 to set it ON or press 0 to set it OFF) •Key in the new site code (4 digits) •Enter programming mode
•ESC X3 •ESC X3 •01 Enter
•02 Enter
Unit Address Site Code 2 •08 Enter
•Enter programming mode •Enter programming mode •Key in the new door pin (6 digits)
•01 Enter •01 Enter •11 Enter
•01 Enter •02 Enter •01
•04 Enter •04 Enter •ESC X3
•Key in the new unit address (00 - 15 sets) •Key in the new site code (4 digits)
•ESC X3 •ESC X3 Door Pin 1 Tz
•Enter programming mode
Reader Mode Site Code 3 •01 Enter
•Enter programming mode •Enter programming mode •02 Enter
•01 Enter •01 Enter •09 Enter
•01 Enter •02 Enter •Key in the new door pin timezone
•05 Enter •05 Enter •ESC X3
•1 Enter (Press 1 to set it ON or press 0 to set it OFF) •Key in the new site code (4 digits)
•ESC X3 •ESC X3
21
Model: EP.MINI
MINI (6 digit firmware) Programming Mode
22
Model: EP.MINI
MINI (6 digit firmware) Programming Mode
Reset Lockout
•Enter programming mode
•02 Enter
•01 Enter
•07 Enter
•1 Enter
•ESC X3
23
Model: EP.MINI
MINI (10 digit firmware) Programming Mode
Admin Pin
•Enter programming mode Inhibit Mode Door Pin 3
•01 Enter •Enter programming mode •Enter programming mode
•01 Enter •01 Enter •01 Enter
•01 Enter •02 Enter •02 Enter
•Key in new admin pin (6 digits) •01 Enter •05 Enter
•ESC X3 •1 Enter (Press 1 to set it ON or press 0 to set it OFF) •Key in the new door pin (6 digits)
•ESC X3 •08 Enter
Normal Pin •01
•Enter programming mode Security Mode •ESC X3
•01 Enter •Enter programming mode
•01 Enter •01 Enter Door Pin 1 Tz
•02 Enter •02 Enter •Enter programming mode
•Key in new normal pin (6 digits) •02 Enter •01 Enter
•ESC X3 •0 Enter (Press 1 to set it ON or press 0 to set it OFF) •02 Enter
•ESC X3 •06 Enter
Security Level •Key in the new door pin timezone
•Enter programming mode Door Pin 1 •ESC X3
•01 Enter •Enter programming mode
•01 Enter •01 Enter Door Pin 2 Tz
•03 Enter •02 Enter •Enter programming mode
•1 Enter (Press 1 to set it ON or press 0 to set it OFF) •03 Enter •01 Enter
•ESC X3 •Key in the new door pin (6 digits) •02 Enter
•06 Enter •07 Enter
Unit Address •01 •Key in the new door pin timezone
•Enter programming mode •ESC X3 •ESC X3
•01 Enter
•01 Enter Door Pin 2 Door Pin 3 Tz
•04 Enter •Enter programming mode •Enter programming mode
•Key in the new unit address (00 - 15 sets) •01 Enter •01 Enter
•ESC X3 •02 Enter •02 Enter
•04 Enter •08 Enter
Reader Mode •Key in the new door pin (6 digits) •Key in the new door pin timezone
•Enter programming mode •07 Enter •ESC X3
•01 Enter •01
•01 Enter •ESC X3
•05 Enter
•1 Enter (Press 1 to set it ON or press 0 to set it OFF)
•ESC X3
MINI programming mode for 10 digit firmware does not have site code
24
Model: EP.MINI
MINI (10 digit firmware) Programming Mode
Exit Button Tz •01 Enter •01 Enter
•Enter programming mode •02 Enter •05 Enter
•01 Enter •14 Enter •03 Enter
•02 Enter •Key in the new card+pin timezone •When finish formatting, a beep sound will be heard
•09 Enter •ESC X3 •ESC X2
•Key in the new exit button timezone
•ESC X3 Date Setting Install Card
•Enter programming mode •Enter programming mode
Auto Release Tz •01 Enter •02 Enter
•Enter programming mode •03 Enter •01 Enter
•01 Enter •Key in the new date (DDMMYY) •01 Enter
•02 Enter •ESC X2 •Key in the card number (10 digits)
•10 Enter •ESC X3
•Key in the new auto release timezone Time Setting
•ESC X3 •Enter programming mode Delete Card
•01 Enter •Enter programming mode
Release Time •04 Enter •02 Enter
•Enter programming mode •Key in the new time (HHMMSS) •01 Enter
•01 Enter •ESC X2 •02 Enter
•02 Enter •Key in the card number (10 digits)
•11 Enter Reset Password •ESC X3
•Key in the new release time (00 – 99) •Enter programming mode
•ESC X3 •01 Enter View Card
•05 Enter •Enter programming mode
Open Time •01 Enter •02 Enter
•Enter programming mode •ESC X2 •01 Enter
•01 Enter •03 Enter
•02 Enter Reset Door Data •Key in the card number (10 digits)
•12 Enter •Enter programming mode •ESC X4
•Key in the new open time (00 – 99) •01 Enter
•ESC X3 •05 Enter Quick Install
•02 Enter •Enter programming mode
Pin Trials •ESC X2 •02 Enter
•Enter programming mode •01 Enter
•01 Enter •04 Enter
•02 Enter •Flash all the cards to be installed (card by card)
•13 Enter •ESC X4
•Key in the new pin trials (00 – 09)
•ESC X3
MINI programming mode for 10 digit firmware does not have site code
25
Model: EP.MINI
MINI (10 digit firmware) Programming Mode
Quick Delete Transaction
•Enter programming mode •Enter programming mode
•02 Enter •02 Enter
•01 Enter •02 Enter
•05 Enter •Press F3 button to view the next transaction event or F1
•Flash all the cards to be deleted (card by card) button to go back to previous transaction event
•ESC X4 •ESC X3
Reset Lockout
•Enter programming mode
•02 Enter
•01 Enter
•07 Enter
•1 Enter
•ESC X3
Total Card
•Enter programming mode
•02 Enter
•01 Enter
•09 Enter
•ESC X3
MINI programming mode for 10 digit firmware does not have site code
26
Model: EP.MINI
Cabling Information
27