The currents given below concern standard three-phase four-pole cage motors (1500 r.p.m. at 50 Hz 1800 r.p.m. at 60 Hz).
These values are given for guidance and may vary according to the motor manufacturer and depending on the number of poles.
1
Overview
2
AX contactors and NX contactor relays
3
Manual motor starters
4
Overload relays
5
General technical data
6
Index
1SYN829571C201
ABB | 1/1
The new AX contactor range
Product overview
1/2 | ABB
The new AX contactor range
Product overview
The new contactor range is designed to provide the performance and features that are required, in a compact and 1
modern design. Control made simple – The performance you need.
ABB | 1/3
3-pole contactors, for motor control and power switching
IEC AC-3 Rated operational power θ ≤ 55 °C, 400 V kW 4 5.5 7.5 11 15 18.5
Main accessories
CA5X-10 (1 x N.O.)
Front mounting CA5X-01 (1 x N.C.)
Auxiliary contact blocks
CA5X-4 pole (add on block with 4 contacts NO or NC combination)
Side mounting CAL5X-11 (1 x N.O. + 1 x N.C.)
TEF5-ON
Timers Electronic
TEF5-OFF
Mechanical VM5-1
Interlocking units
Mechanical / Electrical VE5-1
Surge suppressors Varistor (AC / DC) RV5 (24...440 V)
RC type (AC) RC5-1 (24...440 V)
Overload relays
TA42DU-M (18...42 A)
Electronic
Class 10E,20E,30E E16DU (0.10…18.9A) E45DU(9…45A)
relays
(1) The max AC3 operational current is 23A for AX25 with TA25DU-25M
(2) The max AC3 operational current is 74A for AX80 with TA75DU-80M
(3) The max AC3 operational current is 182A for AX205 with TA200DU-200
1/4 | ABB
1
AX50 AX65 AX80 AX95 AX115 AX150 AX185 AX205 AX260 AX300 AX370
VM300H VM19
VE5-2
TA110DU (66...110 A)
MO496 (32…100 A)
Ics up to 100 kA
MO450 (40…50 A) MO495 (63…100 A)
Ics up to 50 kA Ics up to 50 kA
ABB | 1/5
2
1SYN829571C201
2/0 | ABB
AX contactors and NX contactor relays
AX 3-pole contactors
Ordering details 3-pole contactors 2/3
Main accessories 2/10
Technical data 3-pole contactors 2/16 2
Terminal marking and positioning 2/27
Dimensions 2/28
1SYN829571C201
ABB | 2/1
2
1SYN829571C201
2/2 | ABB
AX09 ... AX25 3-pole contactors
4 to 11 kW
AC operated
Description
AX09 … AX25 contactors are mainly used for controlling 3-phase motors and power circuits
up to 690 V AC.
These contactors are of the block type design with: 2
AX01002AX
Ordering details
IEC Rated control Auxiliary Type Order code Weight
Rated operational circuit voltage contacts
power current
Uc (1) fitted Pkg
400 V θ ≤ 40 °C
(1 pce)
AC-3 AC-1
kW A V 50 Hz V 60 Hz kg
4 22 24 24 1 0 AX09-30-10-81 1SBL901074R8110 0.340
0 1 AX09-30-01-81 1SBL901074R8101 0.340
110 110…120 1 0 AX09-30-10-84 1SBL901074R8410 0.340
0 1 AX09-30-01-84 1SBL901074R8401 0.340
220…230 230…240 1 0 AX09-30-10-80 1SBL901074R8010 0.340
0 1 AX09-30-01-80 1SBL901074R8001 0.340
230…240 240…260 1 0 AX09-30-10-88 1SBL901074R8810 0.340
0 1 AX09-30-01-88 1SBL901074R8801 0.340
400…415 415…440 1 0 AX09-30-10-86 1SBL901074R8610 0.340
0 1 AX09-30-01-86 1SBL901074R8601 0.340
5.5 25 24 24 1 0 AX12-30-10-81 1SBL911074R8110 0.340
0 1 AX12-30-01-81 1SBL911074R8101 0.340
110 110…120 1 0 AX12-30-10-84 1SBL911074R8410 0.340
0 1 AX12-30-01-84 1SBL911074R8401 0.340
220…230 230…240 1 0 AX12-30-10-80 1SBL911074R8010 0.340
0 1 AX12-30-01-80 1SBL911074R8001 0.340
230…240 240…260 1 0 AX12-30-10-88 1SBL911074R8810 0.340
0 1 AX12-30-01-88 1SBL911074R8801 0.340
400…415 415…440 1 0 AX12-30-10-86 1SBL911074R8610 0.340
0 1 AX12-30-01-86 1SBL911074R8601 0.340
7.5 27 24 24 1 0 AX18-30-10-81 1SBL921074R8110 0.340
0 1 AX18-30-01-81 1SBL921074R8101 0.340
110 110…120 1 0 AX18-30-10-84 1SBL921074R8410 0.340
0 1 AX18-30-01-84 1SBL921074R8401 0.340
220…230 230…240 1 0 AX18-30-10-80 1SBL921074R8010 0.340
0 1 AX18-30-01-80 1SBL921074R8001 0.340
230…240 240…260 1 0 AX18-30-10-88 1SBL921074R8810 0.340
0 1 AX18-30-01-88 1SBL921074R8801 0.340
400…415 415…440 1 0 AX18-30-10-86 1SBL921074R8610 0.340
0 1 AX18-30-01-86 1SBL921074R8601 0.340
11 32 24 24 1 0 AX25-30-10-81 1SBL931074R8110 0.340
0 1 AX25-30-01-81 1SBL931074R8101 0.340
110 110…120 1 0 AX25-30-10-84 1SBL931074R8410 0.340
0 1 AX25-30-01-84 1SBL931074R8401 0.340
220…230 230…240 1 0 AX25-30-10-80 1SBL931074R8010 0.340
0 1 AX25-30-01-80 1SBL931074R8001 0.340
230…240 240…260 1 0 AX25-30-10-88 1SBL931074R8810 0.340
1SYN829571C201
ABB | 2/3
AX32, AX40 3-pole contactors
15 to 18.5 kW
AC operated
Description
AX32, AX40 contactors are mainly used for controlling 3-phase motors and power circuits up
to 690 V AC.
2 These contactors are of the block type design with:
– 3 main poles and 1 built-in auxiliary contact
AX02002
Ordering details
IEC Rated control Auxiliary Type Order code Weight
Rated operational circuit voltage contacts
power current
Uc (1) fitted Pkg
400 V θ ≤ 40 °C
(1 pce)
AC-3 AC-1
kW A V 50 Hz V 60 Hz kg
15 55 24 24 1 0 AX32-30-10-81 1SBL281074R8110 0.71
0 1 AX32-30-01-81 1SBL281074R8101 0.71
110 110…120 1 0 AX32-30-10-84 1SBL281074R8410 0.71
0 1 AX32-30-01-84 1SBL281074R8401 0.71
220…230 230…240 1 0 AX32-30-10-80 1SBL281074R8010 0.71
0 1 AX32-30-01-80 1SBL281074R8001 0.71
230…240 240…260 1 0 AX32-30-10-88 1SBL281074R8810 0.71
0 1 AX32-30-01-88 1SBL281074R8801 0.71
400…415 415…440 1 0 AX32-30-10-86 1SBL281074R8610 0.71
0 1 AX32-30-01-86 1SBL281074R8601 0.71
18.5 60 24 24 1 0 AX40-30-10-81 1SBL321074R8110 0.71
0 1 AX40-30-01-81 1SBL321074R8101 0.71
110 110…120 1 0 AX40-30-10-84 1SBL321074R8410 0.71
0 1 AX40-30-01-84 1SBL321074R8401 0.71
220…230 230…240 1 0 AX40-30-10-80 1SBL321074R8010 0.71
0 1 AX40-30-01-80 1SBL321074R8001 0.71
230…240 240…260 1 0 AX40-30-10-88 1SBL321074R8810 0.71
0 1 AX40-30-01-88 1SBL321074R8801 0.71
400…415 415…440 1 0 AX40-30-10-86 1SBL321074R8610 0.71
0 1 AX40-30-01-86 1SBL321074R8601 0.71
(1) for other voltage version see page no. 2/51
1SYN829571C201
2/4 | ABB
AX50 ... AX80 3-pole contactors
22 to 37 kW
AC operated
Description
AX50 … AX80 contactors are mainly used for controlling 3-phase motors and power circuits
up to 690 V AC.
These contactors are of the block type design with: 2
AX03002
– 3 main poles
– control circuit: AC operated
AX50 ... AX80 – add-on auxiliary contact blocks for front or side mounting and a wide range of accessories.
1SYN829571C201
ABB | 2/5
AX50 ... AX80 3-pole contactors
22 to 37 kW
AC operated
Description
AX50 … AX80 contactors are mainly used for controlling 3-phase motors and power circuits
up to 690 V AC.
2 These contactors are of the block type design with:
AX03002
Ordering details
IEC Rated control Auxiliary Type Order code Weight
Rated operational circuit voltage contacts
power current
Uc (1) fitted Pkg
400 V θ ≤ 40 °C
(1 pce)
AC-3 AC-1
kW A V 50 Hz V 60 Hz kg
22 100 24 24 1 1 AX50-30-11-81 1SBL351074R8111 1.16
110 110…120 1 1 AX50-30-11-84 1SBL351074R8411 1.16
220…230 230…240 1 1 AX50-30-11-80 1SBL351074R8011 1.16
230…240 240…260 1 1 AX50-30-11-88 1SBL351074R8811 1.16
400…415 415…440 1 1 AX50-30-11-86 1SBL351074R8611 1.16
30 115 24 24 1 1 AX65-30-11-81 1SBL371074R8111 1.16
110 110…120 1 1 AX65-30-11-84 1SBL371074R8411 1.16
220…230 230…240 1 1 AX65-30-11-80 1SBL371074R8011 1.16
230…240 240…260 1 1 AX65-30-11-88 1SBL371074R8811 1.16
400…415 415…440 1 1 AX65-30-11-86 1SBL371074R8611 1.16
37 125 24 24 1 1 AX80-30-11-81 1SBL411074R8111 1.16
110 110…120 1 1 AX80-30-11-84 1SBL411074R8411 1.16
220…230 230…240 1 1 AX80-30-11-80 1SBL411074R8011 1.16
230…240 240…260 1 1 AX80-30-11-88 1SBL411074R8811 1.16
400…415 415…440 1 1 AX80-30-11-86 1SBL411074R8611 1.16
(1) for other voltage version see page no. 2/51
1SYN829571C201
2/6 | ABB
AX95 ... AX150 3-pole contactors
45 to 75 kW
AC operated
Description
AX95 … AX150 contactors are mainly used for controlling 3-phase motors and power circuits
up to 690 V AC.
These contactors are of the block type design with: 2
AX04002
Ordering details
IEC Rated control Auxiliary Type Order code Weight
Rated operational circuit voltage contacts
power current
Uc (1) fitted Pkg
400 V θ ≤ 40 °C
(1 pce)
AC-3 AC-1
kW A V 50 Hz V 60 Hz kg
45 145 24 24 1 1 AX95-30-11-81 1SFL431074R8111 2.08
110 110…120 1 1 AX95-30-11-84 1SFL431074R8411 2.08
220…230 230…240 1 1 AX95-30-11-80 1SFL431074R8011 2.08
230…240 240…260 1 1 AX95-30-11-88 1SFL431074R8811 2.08
400…415 415…440 1 1 AX95-30-11-86 1SFL431074R8611 2.08
55 160 24 24 1 1 AX115-30-11-81 1SFL981074R8111 2.08
110 110…120 1 1 AX115-30-11-84 1SFL981074R8411 2.08
220…230 230…240 1 1 AX115-30-11-80 1SFL981074R8011 2.08
230…240 240…260 1 1 AX115-30-11-88 1SFL981074R8811 2.08
400…415 415…440 1 1 AX115-30-11-86 1SFL981074R8611 2.08
75 190 24 24 1 1 AX150-30-11-81 1SFL991074R8111 2.08
110 110…120 1 1 AX150-30-11-84 1SFL991074R8411 2.08
220…230 230…240 1 1 AX150-30-11-80 1SFL991074R8011 2.08
230…240 240…260 1 1 AX150-30-11-88 1SFL991074R8811 2.08
400…415 415…440 1 1 AX150-30-11-86 1SFL991074R8611 2.08
(1) for other voltage version see page no. 2/51
1SYN829571C201
ABB | 2/7
AX185, AX205 3-pole contactors
90 to 110 kW
AC operated
Description
AX185, AX205 contactors are mainly used for controlling 3-phase motors and power circuits
up to 690 V AC.
2 These contactors are of the block type design with:
– 3 main poles and side mounted auxiliary contact block
AX05002
2/8 | ABB
AX260 ... AX370 3-pole contactors
132 to 200 kW
AC operated
Description
AX260 … AX370 contactors are mainly used for controlling 3-phase motors and power circuits
up to 690 V AC.
These contactors are of the block type design with: 2
– 3 main poles and side mounted auxiliary contact block
AX06022
1SYN829571C201
ABB | 2/9
AX09 … AX150 3-pole contactors
Main accessories
2
VE5
AX contactor
Interlock unit
RV5, RC5
Surge suppressor
A2
A1
AX contactor
TEF5
Electronic timer
BX4-CA
Protective cover
CA5X
4-pole auxiliary
contact block
CAL5X
2-pole auxiliary
contact block CA5X
1-pole auxiliary
contact block
TA
Thermal overload relay
2/10 | ABB
AX185 ... AX370 3-pole contactors
Main accessories
Main
Mainaccessories
accessories(other accessories
(other available)
accessories available)
AX185, AX205
2
CAL18X-11 CAL18X-11B
2-pole auxiliary 2-pole auxiliary
contact block contact block
VM
Mechanical A2
3
A1 5L
interlock 3L2
-30
185
1L1 AX
3
6T
4T2
LT
2T1
Terminal
shroud
A2
3
A1 5L
AX contactor
3L2 0
5-3
18
1L1 AX
CAL18X-11B
2-pole auxiliary
contact block 3
6T
TA
4T2
2T1
Thermal overload relay
AX contactor
CAL18X-11
2-pole auxiliary
contact block
VM
-30
Mechanical AX
3 00
interlock
-30
3 00
AX
AX contactor
CAL19-11
2-pole auxiliary
contact block LT
Terminal shroud
AX contactor
CAL19-11B
2-pole auxiliary
contact block
EF
1SYN829571C201
ABB | 2/11
LT
A contactor
Terminal
(1) Total number of auxiliary contact blocks for the two contactors.
(2) Interlock type, according to the contactor ratings (see "Accessories").
A210AX260
... A300
... AX370 3 03 10 11 1 2 x CAL18-11 2 x CAL19-11
(1) + 4 +x CAL18-11B
2 x CAL19-11B
(1) + VM...H
+ VM...
(2) (2) B
B B
BBB B
B
1SFC101148C0201
(3) Direct mounting
Contactor - No kit required.
types relays Thermal
Overload
(4) Mounting kit required.
fitting details (1)overload relays
A145, A185 TA200DU (66...200 A) (3)
Contactor types Thermal overload relays Electronic overload relays
A210, A300 TA450DU (130...310 A) (3) or TA450SU (40...310 A) (4)
AX185, AX205 TA200DU (66 ... 200 A) EF205 (63 ... 210 A)
The addition of a thermal or electronic overload relay on the contactor does not prevent fitting of many other accessories as shown in "Main accessory fitting details" table.
1SFC101148C0201
AX260 ... AX370 - EF370 (115 ... 380 A)
(3) Direct mounting - No kit required.
(4) Mounting kit required.
The addition of a thermal overload relay on the contactor does not prevent fitting of many other accessories as shown above.
3/14(1)| Direct
ABB mounting - No kit required.
3/14 | ABB
1SYN829571C201
2/12 | ABB
AX09 … AX150 3-pole contactors
Main accessories
AX09 ... AX40 AX09 ... AX40 Mech. – – VM5-1 1SBN030100R1000 1 0.066
AX95 ... AX205 AX185 ... AX205 Mech. – – VM300H 1SFN034700R1000 1 0.150
Mechanical and electrical interlock units for two horizontal mounted contactors
AX07021
ABB | 2/13
AX09 … AX150 3-pole contactors
Main accessories
For contactors Time delay Delay Auxiliary Type Order code Pkg Weight
range type contacts qty (1 pce)
selected by
2 switch kg
Electronic timers
AX09 ... AX80 0.1...1 s ON-delay 1 1 TEF5-ON 1SBN020312R1000 1 0.065
1SBC101396F0014
qty (1 pce)
kg
AX09…AX18 MS116 / MS132 BEA16/116 1SBN081406R1000 10 0.020
BEA AX25 MS116 / MS 132 BEA25/116 1SBN089306T1000 10 0.020
AX25 MS116 / MS 132 BEA25/132 1SBN089306T1001 10 0.020
AX32 ... AX40 MS450 BEA40/450 1SBN083206R1000 1 0.061
AX50 MS450 BEA50/450 1SBN083506R1000 1 0.062
AX50 ... AX80 MS495 BEA75/495 1SBN084106R1000 1 0.120
AX95 ... AX150 MS495 BEA100/495 1SBN084506R1000 1 0.124
For contactors Rated control circuit Type Order code Pkg Weight
voltage qty (1 pce)
Uc
V AC kg
1SBC574001F0301
Surge suppressors
AX09 ... AX150 24...50 ● RV5/50 1SBN050010R1000 2 0.015
50...133 ● RV5/133 1SBN050010R1001 2 0.015
110...250 ● RV5/250 1SBN050010R1002 2 0.015
RV5/50 250...440 ● RV5/440 1SBN050010R1003 2 0.015
AX09 ... AX40 24...50 ● RC5-1/50 1SBN050100R1000 2 0.012
50...133 ● RC5-1/133 1SBN050100R1001 2 0.012
110...250 ● RC5-1/250 1SBN050100R1002 2 0.012
250...440 ● RC5-1/440 1SBN050100R1003 2 0.012
AX50 … AX150 24...50 ● RC5-2/50 1SBN050200R1000 2 0.015
50...133 ● RC5-2/133 1SBN050200R1001 2 0.015
110...250 ● RC5-2/250 1SBN050200R1002 2 0.015
250...440 ● RC5-2/440 1SBN050200R1003 2 0.015
2/14 | ABB
AX185 ... AX370 3-pole contactors
A145 ... A300 3-pole contactors
Main accessories
Main accessories
contacts
qty (1 pce)
kg 2
kg
Side-mounted instantaneous auxiliary contact blocks
CAL18-11
CAL18X-11 A145 ... A300
Side-mounted 1 blocks
instantaneous auxiliary contact 1 CAL18-11 1SFN010720R1011 2 0.050
AX185 ... AX205 (1)
1 1
1 1
CAL18-11B
CAL18X-11
1SFN010720R3311
1SFN019820R1011 2
2 0.050
0.050 3
1 1
Mechanical interlock unit for two horizontal mounted CAL18X-11B 1SFN019820R3311
contactors 2 0.050
1SBC580411F0301
VM300H
CAL18-11
Main accessories
A145 ... A300 3-pole contactors
1SBC580411F0301
LT...AY
LT...AC
1SBC580411F0301
11C3
VM300H
CAL18-11
Main accessories
A145 ... A300 3-pole contactors
1SFT98099-019C3
LT...AC
1SFT9099-125
orAX260
between...A185 and TA200DU
1SFT9099-125
LT...AL
For contactors
For contactors
Ordering details (1)
LT...AL
For contactors
Ordering
bar LY300
Terminal extension
Terminal
AX185 extension 10.5 20 x 5 LX185 1SFN074707R1000 1 0.250
... A185 with connectors
Terminal enlargements
1SFT98000-012C3
1SFT98000-012C3
1SFT98000-012C3
connectors
Cables For contactors Cable cross section Type Order code Pkg Weight
LX
LX qty (1 pce)
20 x 5
mm
bar
contacts
Auxiliary Type
mm² kg
1SFT98099-011C1
1SFT98099-011C1
1 1
1 1
Surge suppressor
Connector terminals
1SBC580542F0302
1SBC580542F0302
Single Cu
For contactors A145, A185 6...185 –
Rated control circuit Type 1SDA023354R0001
Order code 3
Pkg 0.200
Weight
1SBC574001F0301
LW185
Type
LT300-AY
LT300-AL
LT300-AC
LT185-AY
LT185-AL
LT185-AC 1 11SFN124701R1000
VM300H
CAL18-11B
CAL18-11
RV5/50 Double
AX185 Cu... AX205A145, A185 2250...440
x (50...120) LZ185-2C/120 1SFN074709R1000
RC5-3/440 1SFN050300R1003 2 3 0.300
0.028
Double Al & Cu A210 ... A300 2 x (95...120) – 1SDA025766R0001 3 0.400
1SFN074707R1000
Order
1SFN125104R1000
1SFN125103R1000
1SFN125101R1000
1SFN124704R1000
1SFN034700R1000
1SFN010720R3311
1SFN010720R1011
Order code
(1) For each contactor type, refer to "Main accessory fitting details" table.
LT300-AY
LT300-AL
LT300-AC
LT185-AY
LT185-AL
LT185-AC
VM300H
CAL18-11B
CAL18-11
LZ
code
For contactors Rated control circuit Type Order code Pkg Weight
voltage qty
1SFN125104R1000 kg
1SFN125103R1000
1SFN125101R1000
1SFN124704R1000
1SFN124703R1000
1SFN124701R1000
1SFN034700R1000
1SFN010720R3311
1SFN010720R1011
Order code
Uc (1 pce)
V AC kg
A145 ... A300 250...440 RC5-3/440 1SFN050300R1003 2 0.028
1
qty
Pkg Weight
1
2
2
1
2
2
2
2
qty
Pkg
0.250
(1 pce)
0.075
0.280
0.070
0.050
0.220
0.050
0.150
0.050
0.050
kg
(1 pce)
Weight
1SFC101149C0201
1SFC101149C0201
1SYN829571C201
3 qty
1
2
2
1
2
2
2
2
Pkg
0.075
0.280
0.070
0.050
0.220
0.050
0.150
0.050
0.050
kg
(1 pce)
Weight
ABB | 3/15
ABB | 2/15
3
AX09 ... AX40 3-pole contactors
Technical data
(2) For the protection of motor starters against short circuits, see "Coordination with short-circuit protection devices".
2/16 | ABB
AX50 ... AX150 3-pole contactors
Technical data
ABB | 2/17
AX185 ... AX370 3-pole contactors
Technical data
2/18 | ABB
AX09 ... AX40 3-pole contactors
Technical data
Max. N.O. or N.C. built-in and add-on N.O. or N.C. auxiliary contacts:
see accessory fitting details for 3-pole contactor AX9 ... AX150
Control voltage / Ambient temperature
Mounting 1, 1±30°, 2, 3, 4, 5 at θ ≤ 55 °C 0.85…1.1 x Uc
positions at 55 °C≤ θ ≤ 70 °C Uc
6 at θ ≤ 55 °C 0.95…1.1 x Uc
at θ ≤ 55 °C Unauthorized
Mounting distances The contactors can be assembled side by side
1SYN829571C201
Fixing
On rail according to IEC 60715, EN 60715 35 x 7.5 mm or 35 x 15 mm
By screws (not supplied) 2 x M4 screws placed diagonally
ABB | 2/19
AX50 ... AX150 3-pole contactors
Technical data
2/20 | ABB
AX185 ... AX370 3-pole contactors
Technical data
at θ ≤ 55 °C Unauthorized
Mounting distances The contactors can be assembled side by side
Fixing
On rail according to IEC 60715, EN 60715 -
By screws (not supplied) 4 x M5
ABB | 2/21
AX09 ... AX40 3-pole contactors
Technical data
Connecting characteristics
Contactor types AC operated AX09 AX12 AX18 AX25 AX32 AX40
Main terminals
2
Screw terminals with cable clamp Screw
terminals
with double
connector
2 x (5.6 x 6.5
mm)
Connection capacity (min. ... max.)
Main conductors (poles)
Rigid Solid (≤ 4 mm²) 1x 1...4 mm² 1...6 mm² 2.5...16 mm²
Stranded (≥ 6 mm²) 2x 1...4 mm² 1...6 mm² 2.5...16 mm²
Flexible with ferrule 1x 0.75...2.5 mm² 0.75...6 mm² 2.5...10 mm²
2x 0.75...2.5 mm² 0.75...6 mm² 2.5...10 mm²
Flexible with insulated ferrule 1x - 0.75…4 mm² 2.5...10 mm²
2x - 0.75…2.5 mm² 2.5...10 mm²
Bars or lugs L< 7.7 mm 9.6 mm -
l> 3.7 mm 3.7 mm -
Tightening torque Recommended 1 Nm / 9 Ib.in 1.2 Nm / 11 Ib.in 2.3 Nm / 20 Ib.in
Max. 1.2 Nm 1.5Nm 2.60 Nm
Auxiliary conductors
(built-in auxiliary terminals + coil terminals)
Rigid solid 1x 1...4 mm²
2x 1...4 mm²
Flexible with ferrule 1x 0.75...2.5 mm²
2x 0.75...2.5 mm²
Lugs L< 7.7 mm 8 mm
l> 3.7 mm 3.7 mm
Tightening torque
Coil terminals Recommended 1 Nm / 9 Ib.in
Max. 1.20 Nm
Built-in auxiliary Recommended 1 Nm / 9 Ib.in 1 Nm / 9 Ib.in
terminals Max. 1.20 Nm 1.20 Nm
Degree of protection
acc. to IEC 60947-1 / EN 60947-1 and IEC 60529
Main terminals IP20 (only front side)
Coil terminals IP20 IP20
Built-in auxiliary terminals IP20 (only front side) IP20
Screw terminals Delivered in open position, screws of unused terminals must be tightened
Main terminals M3.5 M5
Screwdriver type Flat Ø 5.5 / Pozidriv 2 Flat Ø 6.5 / Pozidriv 2
Coil terminals M3.5
Screwdriver type Flat Ø 5.5 / Pozidriv 2
Built-in auxiliary terminals M3.5
Screwdriver type Flat Ø 5.5 / Pozidriv 2
1SYN829571C201
2/22 | ABB
AX50 ... AX150 3-pole contactors
Technical data
Connecting characteristics
Contactor types AC operated AX50 AX65 AX80 AX95 AX115 AX150
Main terminals
2
"Screw terminals with single connector "Screw terminals with single connector
(13 x 10 mm)" (14 x 14 mm)"
ABB | 2/23
AX185 ... AX205 3-pole contactors
Technical data
Connecting characteristics
Contactor types AC operated AX185 AX205
Main terminals
2 Flat type
2/24 | ABB
AX260 ... AX370 3-pole contactors
Technical data
Connecting characteristics
Contactor types AC operated AX260 AX300 AX370
Main terminals
Flat type 19.5
2
10.5
ABB | 2/25
AX09 ... AX40 3-pole contactors
Technical data
Built-in auxiliary contacts according to IEC - Other auxiliary contacts see "Accessories"
Contactor types AC operated AX09 AX12 AX18 AX25 AX32 AX40
Rated operational voltage Ue max. 690 V
Rated frequency (without derating) 50/60 Hz
2 Conventional free air thermal current Ith θ ≤ 40 °C 16 A
Ie / Rated operational current AC-15
acc. to IEC 60947-5-1 24-127 V 50/60 Hz 6A
220-240 V 50/60 Hz 4A
380-440 V 50/60 Hz 3A
500 V 50/60 Hz 2A
690 V 50/60 Hz 2A
Making capacity AC-15 10 x Ie AC-15 acc. to IEC 60947-5-1
Breaking capacity AC-15 10 x Ie AC-15 acc. to IEC 60947-5-1
Ie / Rated operational current DC-13
acc. to IEC 60947-5-1 24 V DC 6 A / 144 W
48 V DC 2.8 A / 134 W
72 V DC 2 A / 144 W
110 V DC 1.1 A / 121 W
125 V DC 1.1 A / 138 W
220 V DC 0.55 A / 121 W
250 V DC 0.55 A / 138 W
Short-circuit protection device gG type fuse 10 A
Rated short-time withstand current Icw for 1.0 s 100 A
for 0.1 s 140 A
Minimum switching capacity 12 V / 3 mA
with failure rate acc. to IEC 60947-5-4
Non-overlapping time between N.O. and N.C. contacts ≥ 2 ms
Power dissipation per pole at 6 A 0.1 W
Max. electrical switching frequency AC-15 1200 cycles/h
DC-13 900 cycles/h
Mechanically linked contacts Built-in N.O. or N.C. auxiliary contacts and additional N.O. or N.C. auxiliary contacts of 4-pole
acc. to annex L of IEC 60947-5-1 CA5X are mechanically linked contacts.
Mirror contacts Built-in N.C. auxiliary contacts or additional N.C. auxiliary contacts (CA5X, CAL5X-11) are mirror
acc. to annex F of IEC 60947-4-1 contacts.
1SYN829571C201
2/26 | ABB
AX09 ... AX370 3-pole contactors
Terminal marking and positioning
AX09 ... AX370 3 contactors
Terminal marking and positioning
AX09 ... AX40-30-10 AX09 ... AX40-30-01 AX09 ... AX40-30-10 AX09 ... AX40-30-01
NO 13X
NC 21X
6T3 NO NC
2T1 4T2 A2 2T1 4T2 6T3 14X 22X
A2
AX50 ... AX150-30-11
AX50 ... AX150-30-11
Other possible contact combinations with auxiliary contacts added by the user A1 1L1 3L2 5L3 13 21
NO NC
A1 A2 A1 A2 A1 A2 A1 A2
1L1 3L2 5L3 13 1L1 3L2 5L3 13 1L1 3L2 5L3 13 1L1 3L2 5L3 13
NO NO NO NO NO NC
A2 2T1 4T2 6T3 14 22
21 2- -1 21 33 2- 3- -1 -3 Combination 11
NC = + NC NC NO = + NC + NO
22 2- -2 22 34 2- 3- -2 -4
A1 1L1 3L2 5L3 13 21 33
NO NC NO
NO NO NO NO
2T1 4T2 6T3 14 2T1 4T2 6T3 14 2T1 4T2 6T3 14 2T1 4T2 6T3 14
A2 A2 A2 A2 NO NC NO
A2 2T1 4T2 6T3 14 22 34
Combination 11 = AX09 ... AX40-30-10 + CA5X-01 Combination 21 = AX09 ... AX40-30-10 + CA5X-01 + CA5X-10 Combination 21
A1 A2 A1 A2
1L1 3L2 5L3 1L1 3L2 5L3
A1 A2
NO 13X
NC 21X
A1 1L1 3L2 5L3 13X 21X
NO NC
NC 22X
NO 14X NO NC
A2 2T1 4T2 6T3 14X 22X
ABB | 2/27
AX contactor
Dimensions
Main dimensions mm
(76.3 for AX25)
AX09, AX12, AX18, AX25, NX..E Drilling plan AX09, AX12, AX18, AX25, NX..E
2/28 | ABB
AX contactor
Dimensions
Main dimensions mm
10 140 180
19.5 10.5 35.5 5
33.4
94.7
225
43.75
4X
43.75 M5 10-24 UNC
ABB | 2/29
Star-delta starting of three-phase asynchronous motors
Contactor selection
General
Star-delta starting is the most common method to reduce the starting current of a motor. This system can be used on all the
squirrel cage motors, which are normally used in delta connection.
2 In this type of starting, it is recommended to choose motors having high starting torque i.e. much higher than the resistive
torque in order to reach sufficient high speed when the motor is connected in star.
Star-delta starting
Technical Data
When starting:
–– inrush current is reduced to a third of direct starting current
–– motor torque is reduced to a third or even less of direct
starting torque.
Transient current is generated when switching from star to
delta connection.
Utilization
During the initial starting phase ("star" connection), the
resistive torque of the driven load must remain, irrespective
of speed, less than the "star" motor torque until "star-delta"
switching occurs.
This starting mode is therefore ideal for machines having low
starting torque such as:
–– pumps
–– centrifugal compressors
–– wood-working machines, etc.
In order to prevent a high current peak, at least 85 % of nominal speed must be reached before switching from star to delta.
Precautions
Motor nominal voltage in delta connection must be equal to that of the mains.
Example:
A motor for 415 V star-delta starting must be designed for 415 V in "delta" connection. Its usual designation is "415 V / 690 V
motor". The motor must be constructed with 6 terminal windings.
Sequence
Starting is a three-stage process:
1st stage - "Star" connection
Press the "On" button on the control circuit to close the KM2 "star" contactor. The KM1 "line" contactor then closes and the
motor starts. Countdown of programmed starting time (normally 6 to 16 s) then begins.
2nd stage - "Star" to "Delta" switching
When the programmed starting time is over, the KM2 "star" contactor opens.
3rd stage - "Delta" connection
A transition time (or dwelling time) of 50 ms is fixed between opening of the "star" contactor and closing of the "delta"
contactor by the use of TE5S timer. This prevents short circuit between "star" and "delta".
Note: An electrical interlock between star and delta is mandatory such as VE 5 or through auxiliary contacts.
1SYN829571C201
Furthermore, in open transition, the current interruption may reach up to 95 ms: it shall be checked that this duration is
compatible with the application i.e. mainly if the decreasing in rotation speed is acceptable during the starting phase.
2/30 | ABB
Star-delta starting of three-phase asynchronous motors
Contactor selection
Notes:
(1) To combine with TA25DU-32M
(2) Due to different voltage to select different motor
(3) Usual time value = 6...16 s.
(4) The setting current value is : nominal motor current x 0.58
1SYN829571C201
ABB | 2/31
Notes
Notes
2
1SYN829571C201
114
2/32Notes
| ABB| ABB Low voltage control products
NX contactor relays
Ordering details
NX contactor relays
AC operated 2/34
Main accessories 2/35 2
Technical data 2/36
1SYN829571C201
ABB | 2/33
NX contactor relays
AC operated
Description
NX contactor relays are used for switching auxiliary circuits and control circuits.
These contactor relays are of the block type design with:
2 – 4 poles. Contactor relays have mechanically linked auxiliary contact elements
AX08002
14 24 34 44
220…230 230…240 NX40E-80 1SBH901074R8040 0.340
A2 NO NO NO NO NO NO NO NO
A2 14 24 34 44 A2 14 24 34 44 230…240 240…260 NX40E-88 1SBH901074R8840 0.340
NX40E NX40E NX40E 400…415 415…440 NX40E-86 1SBH901074R8640 0.340
nations with auxiliary contacts added by (1)
thefor user
other voltage version see page no. 2/51
A1 13 21 33 43 53
NO NC NO NO NO
A1 A2 A1 A2
13 23 33 43 13 23 33 43
NO NO NO NO NO NO NO NO NO NC NO NO NO
A2 14 22 34 44 54
-3 51 61 5- 6- -1 -1 Combination X41E
NO NC NC = + NC + NC
cts -4added
nations withbyauxiliary
the
52 62 user
contacts added
5- 6- by the user
-2 -2
NO NO NO NO NO NO NO NO A1 13 21 33 43 53 A1
A1 13
13 2321 3333 4343 5153 61
NO NC NO NO NO NO
NO NONC NONO NONO NC
NO NC
A1 A2 14 A1
24 34 A2
44 14 A1
24 34 A2
44
13 23 33 43 13 23 33 A2
43 13 23 33 A2
43
NO NC NO NO NO NO
NO NONC NONO NONO NC
NO NC
NO NO NO NO NO NO NO NO NO NO NO NO A2 14 2422 3434 4444 5254 62
A2 14 22 34 44 54 A2 14
CA5X-10 Combination X42E = NX40E + CA5X-01 + CA5X-01
-3 5- 6- 51 61 -1 -1 5- 6- Combination
-1 X41E -1 Combination X41E
Combination X42E
= NO NC +
NC NC += NC + NC + NC
-4 5- 6- 52 62 -2 -2 5- 6- -2 -2
NO NO NO NO NO NO NO NO NO NO NO NO A1 13 23 33 43 51 61 A1 13 23 33 43 51 61
NO NO NO NO NC NC NO NO NO NO NC NC
14 24 34 44 14 24 34 44 14 24 34 44
A2 A2 A2 A1 13 23 33 43 53
NO NO NO NO NC NC NO NO NO NO NO
NC NC
A1 A2 A1 A2 A2 14 24 34 44 52 62 A2 14 24 34 44 52 62
=CA5X-10
NX40E 13 +23CA5X-01
Combination + =CA5X-01
33 43 X42E 13 23
NX40E 33 43
+ Combination
CA5X-01 +X42E
CA5X-01
Combination
NO NO
X42E
NO NO NO
NO NO NO NO NO NO NO NO
A2 14 24 34 44 54
-3 53 63 5- 6- -3 -3 Combination X50E
NO NO NO = + NO + NO
-4 54 64 5- 6- -4 -4
NO NO NO NO NO NO NO NO A1 13 23 33 43 53 A1 13 23 33 43 53 63
A1 13
NO 23
NO 33
NO 43
NO 53
NO NO
NO NO NO NO NO NO NO NO NO NO
A1 A2 14 A1
24 34 A2
44 14 A1
24 34 A2
44
13 23 33 43 13 23 33 A2
43 13 23 33 A2
43
NO NO NO NO NO NO NO NO NO NO NO
NO NO NO NO NO NO NO NO NO NO NO NO A2 NO
14 NO
24 NO
34 NO
44 NO
54 64
A2 14 24 34 44 54 A2 14 24 34 44 54
CA5X-10 Combination X60E = NX40E + CA5X-10 + CA5X-10
-3 5- 6- 53 63 -3 -3 5- 6- Combination
-3 X50E -3 Combination
Combination X60E
X50E
= NO NO +
NO NO += NO + NO + NO
-4 5- 6- 54 64 -4 -4 5- 6- -4 -4
NO NO NO NO A1 13 23 33 43 53 63 A1 13 23 33 43 53 63
NO NO NO NO NO NO NO NO NO NO NO NO NO NO NO NO NO NO NO NO
14 24 34 44 14 24 34 44 14 24 34 44
1SYN829571C201
A2 A2 A2
NO NO NO NO NO NO NO NO NO NO NO NO
A2 14 24 34 44 54 64 A2 14 24 34 44 54 64
=CA5X-10
NX40E + CA5X-10X60E
Combination + =CA5X-10
NX40E + Combination
CA5X-10 +X60E
CA5X-10
Combination X60E
2/34 | ABB
NX contactor relays
Main accessories
ABB | 2/35
NX contactor relays
Technical data
2/36 | ABB
NX contactor relays
Technical data
Connecting characteristics
Contactor relay types AC operated NX
Main terminals
Screw terminals Delivered in open position, screws of unused terminals must be tightened
All terminals M3.5
Screwdriver type Flat Ø 5.5 / Pozidriv 2
ABB | 2/37
Add-on auxiliary contacts
Terminal marking and
Add-on auxiliary positioning
contacts
Terminal marking and positioning
NC NO
2 -2 -4
CA5X-01 CA5X-10
NO NC NC NO NO NC NC NO
CAL5X-11, CAL18X-11, CAL19-11 CAL5X-11, CAL18X-11, CAL19-11 CAL18X-11B, CAL19-11B CAL18X-11B, CAL19-11B
(L. h. s. mounted) (R. h. s. mounted) (L. h. s. mounted) (R. h. s. mounted)
NC NC NC NC NC NC NC NC NC NC NC NC NC NC NC NC
12 22 32 42 22 32 42 52 2 2 2 2 52 62 72 82
13 21 31 43 21 31 43 53 3 1 1 3 53 61 71 83
NO NC NC NO NC NC NO NO NO NC NC NO NO NC NC NO
14 22 32 44 22 32 44 54 4 2 2 4 54 62 72 84
13 21 33 43 21 33 43 53 3 1 3 3 51 63 73 83
NO NC NO NO NC NO NO NO NO NC NO NO NC NO NO NO
14 22 34 44 22 34 44 54 4 2 4 4 52 64 74 84
13 23 33 43 21 31 41 53 3 3 3 3 53 63 73 83
NO NO NO NO NC NC NC NO NO NO NO NO NO NO NO NO
14 24 34 44 22 32 42 54 4 4 4 4 54 64 74 84
53 61 71 81
NO NC NC NC
54 62 72 82
CA5X-13N
2/38 | ABB
NX contactor relays
Terminal marking and positioning
NX 4-pole contactor relays
Terminal marking and positioning
A1 A2 A1 A2 A1 A2 2
13 21 31 43 13 21 33 43 13 23 33 43
NO NC NC NO NO NC NO NO
A2 14 22 32 44 A2 14 22 34 44
NO NC NC NO NO NC NO NO NO NO NO NO
NX22E NX31E
A1 13 23 33 43
NO NO NO NO
NO NC NC NO NO NC NO NO NO NO NO NO
14 22 32 44 14 22 34 44 14 24 34 44
A2 A2 A2 NO NO NO NO
A2 14 24 34 44
Other possible contact combinations with auxiliary contacts added by the user
A1 13 21 33 43 53
NO NC NO NO NO
A1 A2 A1 A2 A1 A2 A1 A2
13 21 33 43 13 21 33 43 13 23 33 43 13 23 33 43
NO NC NO NO NO NC NO NO NO NO NO NO NO NO NO NO NO NC NO NO NO
A2 14 22 34 44 54
53 5- -3 51 61 5- 6- -1 -1 Combination X41E
NO = + NO NC NC = + NC + NC
54 5- -4 52 62 5- 6- -2 -2
NO NC NO NO NO NC NO NO NO NO NO NO NO NO NO NO A1 13 23 33 43 51 61
NO NO NO NO NC NC
14 22 34 44 14 22 34 44 14 24 34 44 14 24 34 44
A2 A2 A2 A2
NO NO NO NO NC NC
A2 14 24 34 44 52 62
Combination X41E = NX31E + CA5X-10 Combination X42E = NX40E + CA5X-01 + CA5X-01
Combination X42E
A1 13 23 33 43 53
NO NO NO NO NO
A1 A2 A1 A2 A1 A2 A1 A2
13 23 33 43 13 23 33 43 13 23 33 43 13 23 33 43
NO NO NO NO NO NO NO NO NO NO NO NO NO NO NO NO NO NO NO NO NO
A2 14 24 34 44 54
53 5- -3 53 63 5- 6- -3 -3 Combination X50E
NO = + NO NO NO = + NO + NO
54 5- -4 54 64 5- 6- -4 -4
NO NO NO NO NO NO NO NO NO NO NO NO A1 13 23 33 43 53 63
NO NO NO NO
NO NO NO NO NO NO
14 24 34 44 14 24 34 44 14 24 34 44 14 24 34 44
A2 A2 A2 A2
NO NO NO NO NO NO
A2 14 24 34 44 54 64
Combination X50E = NX40E + CA5X-10 Combination X60E = NX40E + CA5X-10 + CA5X-10
Combination X60E
1SYN829571C201
ABB | 2/39
Add-on auxiliary contacts
Technical data
Contact utilization characteristics according to IEC
Front mounted Side mounted
2 Types 1-pole CA5X, 4-pole CA5X CAL5X-11 CAL18X-11, CAL19-11,
CAL18X-11B, CAL19-11B
Standards IEC 60947-5-1 and EN 60947-5-1
Rated insulation voltage Ui
acc. to IEC 60947-5-1 690 V
Rated operational voltage Ue max. 24...690 V AC
Conventional thermal current Ith - θ ≤ 40 °C 16 A
Ie / Rated operational current AC-15
acc. to IEC 60947-5-1 24-127 V 50/60 Hz 6A
220-240 V 50/60 Hz 4A
380-440 V 50/60 Hz 3A
500-690 V 50/60 Hz 2A
Making capacity 10 x Ie AC-15 acc. to IEC 60947-5-1
Breaking capacity 10 x Ie AC-15 acc. to IEC 60947-5-1
Ie / Rated operational current DC-13
acc. to IEC 60947-5-1 24 V 6 A / 144 W
DC
48 V 2.8 A / 134 W
DC
72 V 1 A / 72 W
DC
110 V 0.55 A / 60 W
DC
125 V 0.55 A / 69 W
DC
220 V 0.3 A / 66 W
DC
250 V 0.3 A / 75 W
DC
Short-circuit protection device gG type fuse 10 A
Rated short-time withstand current Icw for 1.0 s 100 A
θ = 40 °C for 0.1 s 140 A
Minimum switching capacity
AX09 … AX80 contactors 12 V / 3 mA – –
with failure rate acc. to IEC 60947-5-4 ≤ 10 -6 – –
AX95 … AX150 contactors 24 V / 50 mA – 24 V / 50 mA –
(0.5 million of operating
cycles)
Connecting characteristics
Connection capacity (min. ... max.)
Rigid solid 1...4 mm²
1x
1...4 mm²
2x
Flexible with ferrule 0.75...2.5 mm²
1x
0.75...2.5 mm²
2x
Lugs L≤
7.7 mm 8 mm
3.7 mm
l> 3.7 mm
Tightening torque 1 Nm / 9 lb.in
1SYN829571C201
2/40 | ABB
Mechanical and electrical interlock units
Technical data
Contact utilization characteristics according to IEC
Types VE5-1 VE5-2
Standards IEC 60947-5-1 and EN 60947-5-1 2
Rated insulation voltage Ui
acc. to IEC 60947-5-1 690 V
Rated operational voltage Ue max. 24...690 V
Conventional thermal current Ith - Ø ≤ 40 °C 16 A
Ie / Rated operational current AC-15
acc. to IEC 60947-5-1 24-127 V 50/60 Hz 6A
220-240 V 50/60 Hz 4A
380-440 V 50/60 Hz 3A
500-690 V 50/60 Hz 2A
Making capacity 10 x Ie AC-15 acc. to IEC 60947-5-1
Breaking capacity 10 x Ie AC-15 acc. to IEC 60947-5-1
Ie / Rated operational current DC-13
acc. to IEC 60947-5-1 24 V 6A
DC
48 V 2.8 A
DC
72 V 1A
DC
125 V 0.55 A
DC
250 V 0.3 A
DC
Short-circuit protection device - gG type fuse 10 A
Rated short-time withstand current Icw for 1.0 s 100 A
Ø = 40 °C for 0.1 s 140 A
Power dissipation per pole at 6 A 0.15 W
Mechanical durability
Number of operating cycles 5 millions operating cycles
Max. switching frequency 600 cycles/h
Connecting characteristics
Connection capacity (min. ... max.)
Rigid solid 1x 1...4 mm²
2x 1...4 mm²
Flexible with ferrule 1x 0.75...2.5 mm²
2x 0.75...2.5 mm²
Lugs L< 8 mm
l> 3.5 mm
Tightening torque Recommended 1 Nm
Max. 1.2 Nm
Degree of protection IP20
acc. to IEC 60947-1 / EN 60947-1
and IEC 60529 / EN 60529
Screw terminals Delivered in open position, screws of unused terminals must be tightened
All terminals M3.5
Screwdriver type Flat Ø 5.5 / Pozidriv 2
Terminal marking
Technical note: when, during switching, the arc time is estimated to more than 40 ms, the closing signal of one of the two contactors must be delayed with respect to the opening
signal of the other contactor in order to prevent a short-circuit.
Use a TEF5 or TE5S electronic timer according to application use with time lapse for A contators.
1SYN829571C201
ABB | 2/41
Electronic timers
Description
TEF5 frontal electronic timers are used for realizing timing function and are available in ON-
delay and OFF-delay versions.
2 Compact solution in cabinet compared to separate timers
TEF5 electronic timers are front-mounted and locked on A contactors or N contactor relays.
A mechanical indicator allows to show the state of the contactor.
1SBC101396F0014
TEF5 electronic timers are supplied by direct wiring to the coil terminals A1 - A2 of the
contactor or contactor relay. A varistor is integrated on the timer to offer a built-in protection
against surges in the contactor coil.
Available for a wide control voltage range 24...240 V AC / DC
TEF5-OFF
TEF5-ON or TEF5-OFF allow time-delayed functions up to 100 s in 3 distinct time ranges,
independently of the control system. The time delay ranges are selected by a switch and the
time delay can be adjusted by means of a rotary switch. The timing function is activated by
closing or opening the device on which the timer is mounted. The OFF-delay version operates
without additional control supply.
Ordering details
For Time Delay Rated control Auxiliary Type Order code Weight
contactors, delay type circuit contacts
contactor range voltage Pkg
relays selected Uc (1 pce)
by switch V 50/60 Hz
or DC kg
AX09 ... AX80 0.1...1 s ON-delay 24...240 1 1 TEF5-ON 1SBN020312R1000 0.065
NX 4 pole 1...10 s
OFF-delay 24...240 1 1 TEF5-OFF 1SBN020314R1000 0.065
10...100 s
1SYN829571C201
2/42 | ABB
Electronic timers
Technical data
Contact utilization characteristics according to IEC
Types TEF5-ON TEF5-OFF
Standards IEC 60947-5-1 and EN 60947-5-1 2
Rated insulation voltage Ui
acc. to IEC 60947-5-1 400 V
Rated impulse withstand voltage Uimp 4 kV
Rated operational voltage Ue max. 240 V
Rated frequency (without derating) 50 / 60 Hz
Conventional thermal current Ith - Ø ≤ 40 °C 5A
Ie / Rated operational current AC-15
acc. to IEC 60947-5-1 24-127 V 50/60 Hz 3 A
220-240 V 50/60 Hz 1.5 A
Making capacity 10 x Ie AC-15 acc. to IEC 60947-5-1
Breaking capacity 10 x Ie AC-15 acc. to IEC 60947-5-1
Ie / Rated operational current DC-13
acc. to IEC 60947-5-1 24 V DC 1 A / 24 W
Short-circuit protection device gG type fuse 6A
Rated short-time withstand current Icw for 1.0 s 8 A
Ø = 40 °C for 0.1 s 8 A
Minimum switching capacity 12 V / 3 mA
with failure rate acc. to IEC 60947-5-4 24 V DC 10 -7
Power dissipation per pole at 3 A 0.1 W
Function diagram ON-delay OFF-delay
ABB | 2/43
Electronic timers
Technical data
Connecting characteristics
Connection capacity (min. ... max.)
Rigid solid 1x 1...2.5 mm²
2 2x 1...2.5 mm²
Flexible with non insulated ferrule 1x 0.75...2.5 mm²
2x 0.75...2.5 mm²
Flexible with insulated ferrule 1x 0.75...2.5 mm²
2x 0.75...1.5 mm²
Lugs L≤ 8 mm
l> 3.7 mm
Connection capacity acc. to UL / CSA 1 or 2 x AWG 18...14
Stripping length 10 mm
Tightening torque 1 N.m / 9 lb.in
Degree of protection
acc. to IEC 60947-1 / EN 60947-1 and IEC 60529 / EN 60529 IP20
Screw terminals Delivered in open position, screws of unused terminals should be tightened
All terminals M3.5
Screwdriver type Flat Ø 5.5 / Pozidriv 2
Terminal Marking
1SYN829571C201
2/44 | ABB
Electronic timer for star-delta starters
Description
When used in star-delta starters, the TE5S lags the star connection and provides a lapse of
50 ms before the switch over to delta connection.
According to the type of device chosen, the electronic circuit has a 24 V AC / DC, 110 to 2
120 V AC, 220 to 240 V AC or 380 to 440 V AC supply. An output relay with reversing contact
1SBC575582F0302
ensures high current switching. A two-position switch allows selection of one of the two
time delay ranges: 0.8 to 8 s or 6 to 60 s. The 0.1 to 1.0 graduated button allows an initial
setting without steps within the previously selected range which can then be adjusted using a
TE5S... chronometer.
Note: We recommend that you allow for temperature drift for the final adjustment of the time delay setting. Drift: -0.2 % per °C.
Operation
Chart
On energization, the green U indicator light (voltage applied) comes on. Contact 15-16 then
immediately moves to the closed position.
Count-down of the programmed time immediately commences. When the time delay has
elapsed, contact 15-16 opens and at the same time the 50 ms lapse, t2, begins after which
contact 15-18 moves to the closed position. The yellow R indicator light comes on.
On de-energization, the U and R indicator lights go out and, after the 250 ms resetting time,
the device is ready for a new cycle.
Equivalent diagram
Mounting
On 35 x 7.5 mm or 35 x 15 mm mounting rail according to IEC/EN 60715.
Ordering details
For contactors Rated control circuit Type Order code Pkg Weight
voltage qty (1 pce)
Uc
V 50/60 Hz V DC kg
AX09 ... AX205 24 24 TE5S-24 1SBN020010R1001 1 0.080
110...120 – TE5S-120 1SBN020010R1002 1 0.080
220...240 – TE5S-240 1SBN020010R1003 1 0.080
380...440 – TE5S-440 1SBN020010R1004 1 0.080
AX260 ... AX370 24...240 24...240 CT-ERS.21 (1) 1SVR630100R0300 1 0.121
(1) Please refer EPR catalog for CT-ERS.21 timer
Front face
Main dimensions mm, inches
1SYN829571C201
ABB | 2/45
Electronic timer for star-delta starters
Technical data
Utilization characteristics according to IEC
Types TE5S-24 TE5S-120 TE5S-240 TE5S-440
2 Standards IEC 60947-5-1 and EN 60947-5-1
Rated insulation voltage Ui
acc. to IEC 60947-5-1 440 V
Rated operational voltage Ue max. 24 V DC –
24…240 V AC 440 V AC
Conventional free air thermal current Ith 10 A
Ie / Rated operational current AC-15
acc. to IEC 60947-5-1 24-120 V 50/60 Hz 5A –
220-240 V 50/60 Hz 4A –
380-440 V 50/60 Hz – 3A
Ie / Rated operational current DC-13
acc. to IEC 60947-5-1 24 V DC 4A –
Short-circuit protection device - gG type fuse 10 A
Control circuit voltage
AC control voltage Rated supply voltage Uc 24 V AC 110…120 V AC 220…240 V AC 380…440 V AC
50/60 Hz Average consumption 1.5 VA 3.5 VA 6.5 VA 12.5 VA
DC control voltage Rated supply voltage Uc 24 V DC – – –
Average consumption 0.7 W – – –
Rated frequency limits 48…63 Hz
Supply voltage range 0.85…1.1 x Uc
Overvoltage protection Built-in varistor
Load factor 100 %
Time delay range (t1) selected by switch 0.8…8 s and 6…60 s
Temperature drift -0.2 % per °C
Mechanical setting accuracy ±15 % of the setting range
On-load reiteration accuracy under constant conditions ±2 % after 1 million operating cycles
Minimum time lapse (t2) 50 ms
Minimum time lapse after 1 million of operating cycles 40 ms
Resetting time (max.) 250 ms
Front panel display green indicator light Energization
yellow indicator light Output relay activated
Ambient air temperature
Operation -25…+60 °C
Storage -40…+85 °C
Shock withstand
acc. to IEC 60068-2-27 and EN 6006-2-27
Shock direction
A 20 g / 11 ms
B 15 g / 11 ms
C 20 g / 11 ms
Vibration withstand 10 to 300 Hz in the 3 directions
acc. to IEC 60068-2-6 and EN 60068-2-6 3g
Mechanical durability 5 millions operating cycles
Electrical durability 1 million operating cycles
On-load maximum switching frequency 720 cycles/h 600 cycles/h
Fixing
On rail according to IEC 60715, EN 60715 35 x 7.5 mm or 35 x 15 mm
Connecting characteristics
Connection capacity (min. ... max.)
Rigid solid 1 x 1...2.5 mm²
2 x 1...2.5 mm²
Flexible with ferrule 1 x 0.75...2.5 mm²
2 x 0.75...2.5 mm²
Tightening torque Recommended 0.6 Nm
Max. 0.8 Nm
Degree of protection
acc. to IEC 60947-1 / EN 60947-1 and IEC 60529 / EN 60529 IP20
1SYN829571C201
Screw terminals Delivered in open position, screws of unused terminals must be tightened
All terminals M2.5
Screwdriver type Flat Ø 4 / Pozidriv 1
2/46 | ABB
Surge suppressors for contactor coils
Ordering details
For contactors Rated control circuit Type Order code Pkg Weight
voltage qty (1 pce)
2
Uc
V AC kg
1SBC574001F0301
Surge suppressors
AX09 ... AX150 24...50 ● RV5/50 1SBN050010R1000 2 0.015
50...133 ● RV5/133 1SBN050010R1001 2 0.015
110...250 ● RV5/250 1SBN050010R1002 2 0.015
RV5/50 250...440 ● RV5/440 1SBN050010R1003 2 0.015
AX09 ... AX40 24...50 ● RC5-1/50 1SBN050100R1000 2 0.012
50...133 ● RC5-1/133 1SBN050100R1001 2 0.012
110...250 ● RC5-1/250 1SBN050100R1002 2 0.012
250...440 ● RC5-1/440 1SBN050100R1003 2 0.012
AX50 … AX150 24...50 ● RC5-2/50 1SBN050200R1000 2 0.015
50...133 ● RC5-2/133 1SBN050200R1001 2 0.015
110...250 ● RC5-2/250 1SBN050200R1002 2 0.015
250...440 ● RC5-2/440 1SBN050200R1003 2 0.015
AX185 ... AX205 250...440 RC5-3/440 1SFN050300R1003 2 0.028
1SYN829571C201
ABB | 2/47
Surge suppressors for contactor coils
Technical data
Varistor RV5/50 RV5/133 RV5/250 RV5/440
Rated control circuit voltage Uc 24...50 V AC 50...133 V AC 110...250 V AC 250...440 V AC
2 24...50 V DC 50...133 V DC 110...250 V DC 250...440 V DC
Residual overvoltage (clipping voltage) 132 V AC 270 V AC 480 V AC 825 V AC
132 V DC 270 V DC 480 V DC 825 V DC
Opening time growth factor 1.1...1.5
Operating temperature -20...+70 °C
Connection to the coil terminals (parallel mounting) Clip-on for both fixing and connection.
Fixing Clipped onto the top part of the contactor base without change in contactor overall dimensions.
Advantages High energy absorption: good damping - Unpolarized system.
Drawback Clipping as from Uvdr (1), thus voltage front up to this point.
(1) Uvdr = Varistor operating voltage (voltage dependent resistor), tolerance ±10 %.
Wiring diagrams
Varistor RC type
Dimensions
2/48 | ABB
Mechanical
Mechanicallatching
latchingunits
units
Description
For converting standard contactors into latched contactors.
1SBC565483F0301
Description
The WB75-A block contains a mechanical latching device with electromagnetic impulse unlatching (AC or
DC)converting
For or manual unlatching.
standard contactors into latched contactors.
1SBC565483F0301
Captive screw type connecting terminals, built-in cable clamps, M3.5 (+,-) pozidriv 2 screw with screwdriver
The WB75-A block contains a mechanical latching device with electromagnetic impulse
guidance; delivered untightened and protected against accidental direct contact.
WB75-A unlatching (AC or DC) or manual unlatching. 2
Operation
3 Captive screwthe
After closing, type connecting
contactor terminals,
continues built-in
to be held in the cable
closed clamps, M3.5
position by (+,-) pozidriv
the latching 2 screw
mechanism should the
WB75-A supply voltage fail at the contactor coil terminals.
with screwdriver guidance; delivered untightened and protected against accidental direct
Contactor opening can be controlled:
c ontact.
– electrically by an impulse (AC or DC) on the WB75-A block coil.
(the coil is not designed to be permanently energized)
Operation
– manually by pressing the pushbutton on the front face of the WB75-A block.
After closing, the contactor continues to be held in the closed position by the latching
Mounting
E1 E2 mechanism
The WB75-Ashould
block isthe supply
clipped voltage
onto failface
the front at of
thethecontactor coil terminals.
1-stack contactor where it takes up two slots. The
two other slots may accept CA5... single pole auxiliary contacts (1 block on each side of the mechanical
Contactor opening can be controlled:
Terminal
Terminal marking
marking latch).
electrically by an impulse (AC or DC) on the WB75-A block coil.
(the coil is not designed to be permanently energized)
Ordering details
manually by pressing the pushbutton on the front face of the WB75-A block.
For contactors Rated control circuit Type Order code Pkg Weight
voltage qty (1 pce)
Uc
Mounting
V 50 Hz
The WB75-A block is clipped onto the front face of the 1-stack contactor where it takes up
or DC V 60 Hz kg
two slots.
A9 ... A75 The two other slots
24 may accept
24...28 CA5X... single poleFPTN372726R1001
WB75-A auxiliary contacts (1 block
1 on
0.120
each side of the mechanical42latch). 42...48 WB75-A FPTN372726R1002 1 0.120
48 48...55 WB75-A FPTN372726R1003 1 0.120
110 110...127 WB75-A FPTN372726R1004 1 0.120
Ordering details 220...230 220...255 WB75-A FPTN372726R1006 1 0.120
For contactors 230...240
Rated control230...277
circuit WB75-A
Type FPTN372726R1005
Order code Pkg1 Weight
0.120
380...415 380...440 WB75-A FPTN372726R1007 1 0.120
voltage qty (1 pce)
415...440 440...480 WB75-A FPTN372726R1008 1 0.120
Uc
V 50 Hz
or DC V 60 Hz kg
AX09 ... AX80 24 24...28 WB75-A FPTN372726R1001 1 0.120
42 42...48 WB75-A FPTN372726R1002 1 0.120
48 48...55 WB75-A FPTN372726R1003 1 0.120
110 110...127 WB75-A FPTN372726R1004 1 0.120
220...230 220...255 WB75-A FPTN372726R1006 1 0.120
230...240 230...277 WB75-A FPTN372726R1005 1 0.120
380...415 380...440 WB75-A FPTN372726R1007 1 0.120
415...440 440...480 WB75-A FPTN372726R1008 1 0.120
1SBC101903S0201
1SYN829571C201
3/72 | ABB
ABB | 2/49
Mechanical latching units
Technical data
Utilization characteristics according to IEC
Type WB75-A
2
Rated insulation voltage Ui acc. to IEC 60947-1 690 V
Max. electrical impulse time
On AC coil (with load factor 5 %) 20 s
On DC coil (with load factor 3 %) 8s
Min. electrical impulse time
For latching (energizing of the contactor coil) AC 50 ms
For pull-out (energizing of the WB block coil) AC 30 ms
Coil operating limits AC or DC supply 0.85…1.1 x Uc
AC control voltage 50/60 Hz
Rated control circuit voltage Uc 24…480 V AC
Coil consumption Average pull-in value 90 VA
Average holding value 60 VA
DC control voltage
Rated control circuit voltage Uc 24…440 V DC
Coil consumption Average pull-in value 110 W
Average holding value 110 W
Operating time
On contactor closing (latching)
Between coil energization and:
N.O. contact closing No difference with the operation of a contactor without mechanical latching unit
N.C. contact opening No difference with the operation of a contactor without mechanical latching unit
On contactor opening
(unlatching)
Between WB coil energization N.O. contact opening 5…25 ms
and: N.C. contact closing 7…28 ms
Mechanical durability
Number of operating cycles 1 million operating cycles
Max. switching frequency 3600 cycles/h with on-load factor of 8 %
Connecting characteristics
Connection capacity (min. ... max.)
Rigid solid 1x 1...4 mm²
2x 1...4 mm²
Flexible with ferrule 1x 0.75...2.5 mm²
2x 0.75...2.5 mm²
l L
Lugs L< 8 mm
l> 3.5 mm
Tightening torque Recommended 1 Nm
Max. 1.2 Nm
Screw terminals Delivered in open position, screws of unused terminals must be tightened
All terminals M3.5
Screwdriver type Flat Ø 5.5 / Pozidriv 2
1SYN829571C201
2/50 | ABB
Voltage code table
The below tables indicate the available coil voltages and corresponding digits for order codes. When placing an order, please give
the order code. Select a standard contactor from ordering detail pages. Change the coil voltage code in the order code according
to the table below. Example: for contactor AX40-30-10 and coil 80 V 50/60 Hz, the order code is 1SBL321074R8010.
2
AX contactors
AC coil code
Auxiliary contact Contactors: AX
N.O. N.C.
Type Order code
50 Hz 60 Hz
AX 40 - 30 - 10 1SBL321074R 80 10 81 24 V 24 V
83 48 V 48 V
84 110 V 110...120 V
36 190 V 220 V
N.O. N.C.
Main contacts
80 220...230 V 230...240 V
88 230...240 V 240...260 V
85 380...400 V 400...415 V
86 400...415 V 415...440 V
AC-3 Current rating
Codes in bold for dual frequency coils.
AX Contactor type
AC operated
ABB | 2/51
3
1SYN829571C201
3/0 | ABB
Manual motor starters
Overview
3
Ics up to 100 kA
MS132 manual motor starters 3/7
Technical data 3/8
1SYN829571C201
ABB | 3/1
Manual motor starters
2CDC241010F0011
1SBC101232F0010
3
Thermal and electromagnetic protection Type MS116 MS132
Main accessories
Auxiliary contacts
Signalling contacts
Busbar systems
Feeder terminals S1
3/2 | ABB
2CDC241004F0009
2CDC241020F0011
1SBC101184F0014
3
MS450 MS495 MS497
HK4
HKS4
SK4
SK4
AA4
UA4
PS4 -
1SYN829571C201
S4 -
ABB | 3/3
MS116 manual motor starters
0.10 to 32 A – with thermal and electromagnetic protection
Description
Manual motor starters (MMS) are protection devices for the main circuit. They combine motor
control and protection in a single device. MMS are used mainly to switch motors manually ON/
OFF and protect them and the installation fuse less against short-circuit, overload and phase
failures. Fuse less protection with a manual motor starter saves costs, space and ensures a
2CDC241010F0011
quick reaction under short-circuit condition, by switching off the motor within milliseconds.
3 MS116 is a compact and economic range for motor protection up to 15.5 kW (400 V) /
32 A in width of 45 mm. Further features are the build-in disconnect function, temperature
MS116-16 compensation, trip-free mechanism and a rotary handle with a clear switch position indication.
The manual motor starter is suitable for three- and single-phase applications. Auxiliary
contacts, signalling contacts, undervoltage releases, shunt trips, three-phase bus bars, power
in-feed blocks and locking devices for protection against unauthorized changes are available
as accessory.
Ordering details
Rated Setting Short-circuit Rated Type Order code Weight
2CDC241001F0011
3/4 | ABB
MS116 manual motor starters
Technical data
ABB | 3/5
MS116 manual motor starters
Technical data
Connecting characteristics
Main circuit
Type MS116 ≤ 16 A MS116 ≥ 20 A
Connecting capacity
Rigid 1 or 2 x 1 ... 4 mm² 2.5 ... 6 mm²
Flexible with ferrule 1 or 2 x 0.75 ... 2.5 mm² 1 ... 6 mm²
Flexible with insulated 1 or 2 x 0.75 ... 2.5 mm² 1 ... 6 mm²
ferrule
Flexible 1 or 2 x 0.75 ... 2.5 mm² 1 ... 6 mm²
Stripping length 9 mm 10 mm
Tightening torques 0.8 ... 1.2 Nm / 10 … 12 Ib.in 2.0 Nm / 18 Ib.in
Connection screw M3.5 (Pozidriv 2 / 5.5 mm) M4 (Pozidriv 2 / 6.5 mm)
2CDC242001F0011
1SYN829571C201
3/6 | ABB
MS132 manual motor starters
0.10 to 32 A – with thermal and electromagnetic protection
Description
Manual motor starters (MMS) are protection devices for the main circuit. They combine motor
control and protection in a single device. MMS are used mainly to switch motors manually ON/
OFF and protect them and the installation fuse less against short-circuit, overload and phase
failures. Fuse less protection with a manual motor starter saves costs, space and ensures a
1SBC101232F0010
quick reaction under short-circuit condition, by switching off the motor within milliseconds.
MS132 is a compact and powerful range for motor protection up 15.5 kW (400 V) / 32 3
A in width of 45 mm. Further features are the build-in disconnect function, temperature
compensation, trip-free mechanism and a rotary handle with a clear switch position indication.
MS132-10 The manual motor starter is suitable for three- and single-phase applications. The handle is
lockable to protect against unauthorized changes. Auxiliary contacts, signalling contacts,
undervoltage releases, shunt trips, three-phase bus bars, power in-feed blocks.
Ordering details
Rated Setting Short- Rated Type Order code Weight
operational range circuit instantaneous (1 pce)
power breaking short-circuit
2CDC241001F0011
ABB | 3/7
MS132 manual motor starters
Technical data
3/8 | ABB
MS132 manual motor starters
Technical data
Connecting characteristics
Main circuit
Type MS132-0.16 … MS132-10 MS132-12 … MS132-16 MS132-20 … MS132-32
Connecting capacity
Rigid 1 or 2 x 1 ... 4 mm² 1 ... 4 mm² 2.5 ... 6 mm²
Flexible with ferrule 1 or 2 x 1 ... 4 mm² 1 ... 4 mm² 2.5 ... 6 mm²
Flexible with insulated 1 or 2 x 1 ... 4 mm² 1 ... 4 mm² 2.5 ... 6 mm²
ferrule
Flexible 1 or 2 x 1 ... 4 mm² 1 ... 4 mm² 2.5 ... 6 mm²
Stripping length 9 mm 10 mm 10 mm
Tightening torques 0.8 ... 1.2 Nm / 10 … 12 1.5 Nm / 14 Ib.in 2.0 Nm / 18 Ib.in
Ib.in
Connection screw M3.5 (Pozidriv 2) M4 (Pozidriv 2) M4 (Pozidriv 2)
2CDC242016F0009
1SYN829571C201
MS132 ≤ 10 A MS132 ≥ 12 A
ABB | 3/9
MO132 manual motor starters magnetic only
0.16 to 32 A – with electromagnetic protection
Description
Manual motor starters magnetic only are electromechanical protection devices for the main
circuit. They are used mainly to switch motors manually ON/OFF and protect them fuse less
against short-circuit.
2CDC241009F0011
Fuse less protection with a manual motor starter saves costs, space and ensures a quick
reaction under short-circuit condition, by switching off the motor within milliseconds. Fuse less
3 starter combinations are setup together with contactors and overload relays.
Ordering details
MO132-6.3 Rated Rated Short-circuit Rated Type Order code Weight
operational operational breaking instantaneous (1 pce)
power current capacity Ics short-circuit
400 V at 400 V AC current setting
AC-3 (1) li
kW A kA A kg
0.03 0.16 100 1.56 MO132-0.16 1SAM360000R1001 0.215
0.06 0.25 100 2.44 MO132-0.25 1SAM360000R1002 0.215
2CDC241008F0011
3/10 | ABB
MO132 manual motor starters magnetic only
Technical data
ABB | 3/11
MO132 manual motor starters magnetic only
Technical data
Connecting characteristics
Main circuit
Type MO132-0.16 … MO132-10 MO132-12 … MO132-16 MO132-20 … MO132-32
Connecting
capacity
Rigid 1 or 2 x 1 ... 4 mm² 1 ... 4 mm² 2.5 ... 6 mm²
Flexible with ferrule 1 or 2 x 0.75 ... 2.5 mm² 0.75 ... 2.5 mm² 1 ... 6 mm²
Flexible with insulated ferrule 1 or 2 x 0.75 ... 2.5 mm² 0.75 ... 2.5 mm² 1 ... 6 mm²
Flexible 1 or 2 x 0.75 ... 2.5 mm² 0.75 ... 2.5 mm² 1 ... 6 mm²
Stripping length 9 mm 10 mm 10 mm
Tightening 0.8 ... 1.2 Nm / 10 … 12 1.5 Nm / 14 Ib.in 2.0 Nm / 18 Ib.in
torques Ib.in
Connection screw M3.5 (Pozidriv 2) M4 (Pozidriv 2) M4 (Pozidriv 2)
2CDC242006F0011
MO132 ≤ 10 A MO132 ≥ 12 A
3/12 | ABB
MS116, MS132, MO132 manual motor starters
Main accessories
2CDC246001F0013
MS132 manual motor starters with accessories
1SYN829571C201
1SBC500311F0000
ABB | 3/13
MS116, MS132, MO132 manual motor starters
Main accessories
MS116, MS132, MO132 manual motor starters
Main accessories
1SBC101208F0014
Description
1SBC101208F0014
Description
Manualmotor
Manual motor starters
starters cancan be equipped
be equipped with auxiliary
with auxiliary contacts contacts for lateral/front
for lateral/front mounting, mounting,
signalling contact
HKF1-11
for lateral mounting, undervoltage release and shunt trips. Two different signallingtrips.
signalling contact for lateral mounting, undervoltage release and shunt Two are
contacts different
available.
The
signalling contacts are available. The accessories can be fitted wiring free and without as
accessories can be fitted wiring free and without tools. A variety of combinations is possible tools.
HKF1-11 required for the application. The auxiliary contacts change position with the main contacts. The signalling
A variety of combinations is possible as required for the application. The auxiliary contacts 2
contact SK signals tripping regardless if it was caused by short-circuit or overload. The signalling contact
change
CK signalsposition
tripping with theit main
in case contacts.
was caused The signalling
by short-circuit. contact SK
Undervoltage signals
release tripping
are used regardless if
for remote
3 it was caused
tripping by short-circuit
of the manual motor starter orespecially
overload.forThe signalling
emergency contact
stop circuits.CK signals
Shunt trips tripping
release thein case
MMS it
used for remote
was caused bytripping.
short-circuit. Undervoltage release are used for remote tripping of the manual
motor starter especially for emergency stop circuits. Shunt trips release the MMS used for
remote tripping.
1SBC101209F0014
Ordering details
Suitable for Auxiliary
Auxiliary Description Type Order code Pkg Weight
Ordering details
contacts contacts qty (1 pce)
1SBC101209F0014
N.O. N.C.
Suitable for Auxiliary Auxiliary Description Type Order code Pkg Weight
kg
HK1-11 contacts contacts qty (1 pce)
Auxiliary contacts – mountable on the front
N.O. N.C.
MS116, MS132, 1 1 HKF1-11 1SAM201901R1001 10 0.015
kg
MO132 2 0 HKF1-20 1SAM201901R1002 10 0.015
HK1-11
Auxiliary contacts – mountable on the front
Auxiliary contacts – mountable on the right
MS116, 1 1 HKF1-11 1SAM201901R1001 10 0.015
MS116, MS132, 1 1 max. 2 pieces HK1-11 1SAM201902R1001 2 0.035
MS132,
MO132 2 0 HKF1-20 1SAM201901R1002 10 0.015
2 0 max. 2 pieces HK1-20 1SAM201902R1002 2 0.035
MO132 0 2 max. 2 pieces HK1-02 1SAM201902R1003 2 0.035
2 – mountable
Auxiliary contacts 0 on with
the lead
rightcontacts HK1-20L 1SAM201902R1004 2 0.035
1SBC101210F0014
MS116,
Signalling 1
contacts 1
– mountable on max. 2 pieces
the right HK1-11 1SAM201902R1001 2 0.035
MS116,
MS132, MS132, 12 10 max.alarm,
for tripped 2 pieces SK1-11HK1-20 1SAM201902R1002
1SAM201903R1001 22 0.035
0.035
MO132 0 2 max. max.
2 pieces2 pieces HK1-02 1SAM201902R1003 2 0.035
1SBC101210F0014
MO132
22 00 for tripped
with alarm,
lead contactsSK1-20HK1-20L 1SAM201903R1002
1SAM201902R1004 22 0.035
0.035
SK1-11 max. 2 pieces
Signalling contacts
0 – mountable
2 onforthe right
tripped alarm, SK1-02 1SAM201903R1003 2 0.035
MS116, 1 1 max. for
2 pieces
tripped alarm, SK1-11 1SAM201903R1001 2 0.035
SK1-11 MS132 1 1 for short-circuit alarm, CK1-11 1SAM301901R1001 2 0.035
MS132, max. 2 pieces
max. 2 pieces
MO132 2 0 for tripped alarm, SK1-20 1SAM201903R1002 2 0.035
2 0 for short-circuit alarm, CK1-20 1SAM301901R1002 2 0.035
max. max.
2 pieces2 pieces
00 22 for short-circuit
for tripped alarm,
alarm, CK1-02SK1-02 1SAM301901R1003
1SAM201903R1003 22 0.035
0.035
max. 2 pieces
max. 2 pieces
1SBC101286F0014
max. 2 pieces
3.54"
42.1 1.66"
90
1SYN829571C201
2CDC242001F0012
2CDC131050C0201
42.3 1.67"
68.8 2.71"
HK1
HK1
Ordering
Orderingdetails
details
Suitable
Suitablefor for Rated
Ratedcontrol supply
control Frequency
Frequency Type
Type Order codecode
Order Pkg
Pkg Weight
Weight
voltage qty (1 pce)
supply voltage qty (1 pce)
2 V Hz kg
1SBC101211F0014
V Hz kg
Shunt trips – mountable on the left
1SBC101211F0014
ShuntMS132,
MS116, trips – 20...24
mountable on the left50/60 AA1-24 1SAM201910R1001 1 0.100
MO132
MS116, 110
20...24 50/60
50/60 AA1-110
AA1-24 1SAM201910R1002
1SAM201910R1001 11 0.100
0.100 3
MS132, 200...240
110 50/60
50/60 AA1-230
AA1-110 1SAM201910R1003
1SAM201910R1002 11 0.100
0.100
AA1-24 350...415
200...240 50/60
50/60 AA1-400
AA1-230 1SAM201910R1004
1SAM201910R1003 11 0.100
0.100
AA1-24 MO132
350...415 – mountable
Undervoltage releases 50/60
on the left AA1-400 1SAM201910R1004 1 0.100
MS116, MS132, 24 50
Undervoltage releases – mountable on the left UA1-24 1SAM201904R1001 1 0.100
MO132 4824 50 50 UA1-48 1SAM201904R1002 11 0.100
MS116, UA1-24 1SAM201904R1001 0.100
60 50 UA1-60 1SAM201904R1003 1 0.100
MS132, 48 50 UA1-48 1SAM201904R1002 1 0.100
110...120 50/60 UA1-110 1SAM201904R1004 1 0.100
MO132 60 50 UA1-60 1SAM201904R1003 1 0.100
208 60 UA1-208 1SAM201904R1008 1 0.100
110...120 50/60 UA1-110 1SAM201904R1004 1 0.100
230...240 50/60 UA1-230 1SAM201904R1005 1 0.100
208
400 50 60 UA1-208
UA1-400 1SAM201904R1008
1SAM201904R1006 11 0.100
0.100
1SBC101212F0014
UA1-24
UA1-24
37 1.46"
90
45
2CDC242002F0012
2CDC242002F0012
2CDC131050C0201
1SYN829571C201
70 2.76"
AA1, UA1
AA1, UA1
2/18 | ABB
ABB | 3/15
MS116, MS132, MO132 manual motor starters
Main accessories
Connecting charateristics
Auxiliary circuit
Type HK1 SK1 HKF1
Connecting capacity
Rigid 1 or 2 x 1 ... 1.5 mm² 1 ... 2.5 mm²
Flexible with ferrule 1 or 2 x 0.75 ... 1.5 mm²
Flexible with insulated 1 or 2 x 0.75 ... 1.5 mm²
ferrule
Flexible 1 or 2 x 0.75 ... 1.5 mm²
Stripping length 8 mm
Tightening 0.8 ... 1.2 Nm / 7 Ib.in
torques
Connection M3 (Pozidriv 2)
screw
1SYN829571C201
3/16 | ABB
MS450, MS495, MS497 manual motor starters
22 to 100 A – with thermal and electromagnetic protection
MS450, MS495, MS497 manual motor starters
22 to 100 A – with thermal and electromagnetic protection
Description
Description
Manual motorstarters
Manual motor starters (MMS)
(MMS) are are protection
protection devices
devices for the for thecircuit.
main mainTheycircuit. They motor
combine combine motor
control and
control and protection in a single device. MMS are used mainly to switch motors
protection in a single device. MMS are used mainly to switch motors manually ON/OFF and protect them manually ON/
and the installation fuse less against short-circuit, overload and phase failures. Fuse
OFF and protect them and the installation fuse less against short-circuit, overload and phase less protection with
2 a manual motor starter saves costs, space and ensures a quick reaction under short-circuit condition, by
failures. Fuse less protection with a manual motor starter saves costs, space and ensures a
2CDC241004F0009
AC-3
15.8 28.0…40.0 Ics
25 at 400 520.00 MS450-40 1SAM450000R1005 1.047
22 36.0…45.0 V
25 AC 585.00 MS450-45 1SAM450000R1006 1.039
kW
22 A
40.0…50.0 kA
25 A
650.00 MS450-50 1SAM450000R1007 kg
1.027
MS450
MS495 manual
manualmotor
motorstarters
starters
MS495-40
MS495-40 15.8
30 28.0…40.0
45.0…63.0 25
25 520.00
819.00 MS450-40
MS495-63 1SAM450000R1005
1SAM550000R1007 1.047
2.247
37
22 57.0…75.0
36.0…45.0 25
25 975.00
585.00 MS495-75
MS450-45 1SAM550000R1008
1SAM450000R1006 2.253
1.039
45
22 70.0…90.0
40.0…50.0 25
25 1170.00
650.00 MS495-90
MS450-50 1SAM550000R1009
1SAM450000R1007 2.280
1.027
55 80.0…100.0 25 1235.00 MS495-100 1SAM550000R1010 2.295
MS495 manual motor starters
MS497 manual
30 motor starters
45.0…63.0 25 819.00 MS495-63 1SAM550000R1007 2.247
15 22.0…32.0 50 416.00 MS497-32 1SAM580000R1004 2.222
37 57.0…75.0 25 975.00 MS495-75 1SAM550000R1008 2.253
18.5 28.0…40.0 50 520.00 MS497-40 1SAM580000R1005 2.203
45 70.0…90.0 25 1170.00 MS495-90 1SAM550000R1009 2.280
22 36.0…50.0 50 650.00 MS497-50 1SAM580000R1006 2.230
55 80.0…100.0 25 1235.00 MS495-100 1SAM550000R1010 2.295
30 45.0…63.0 50 819.00 MS497-63 1SAM580000R1007 2.255
37
MS497 manual57.0…75.0 50
motor starters 975.00 MS497-75 1SAM580000R1008 2.266
2CDC241020F0011
45
15 70.0…90.0
22.0…32.0 50 50 1170.00
416.00 MS497-90
MS497-32 1SAM580000R1009
1SAM580000R1004 2.268
2.222
2CDC241020F0011
55
18.5 80.0…100.0
28.0…40.0 50 50 1235.00
520.00 MS497-100
MS497-40 1SAM580000R1010
1SAM580000R1005 2.275
2.203
22 36.0…50.0 50 650.00 MS497-50 1SAM580000R1006 2.230
30 45.0…63.0 50 819.00 MS497-63 1SAM580000R1007 2.255
MS497-100
MS497-100 37 57.0…75.0 50 975.00 MS497-75 1SAM580000R1008 2.266
45 70.0…90.0 50 1170.00 MS497-90 1SAM580000R1009 2.268
55 80.0…100.0 50 1235.00 MS497-100 1SAM580000R1010 2.275
45 1.77"
85 3.35"
130 5.12"
140 5.51"
155 6.10"
45 1.77"
165 6.50"
116 4.57"
150 5.91"
1SYN829571C201
2CDC242013F0011
2CDC242014F0011
2CDC131042C0201
30 1.18" 8 0.32"
5 0.20" 109 4.29" 30 1.18" 7 0.28"
55 2.17" 127 5.0" 5 0.20" 132 5.20"
132 5.2" 70 2.56" 153 6.02"
144 5.67" 169 6.65"
MS497-32: No need for back-up fuse in networks with a prospective current of up to 100 kA at 440 V.
MS497-90: No need for back-up fuse in networks with a prospective current of up to 70 kA at 440 V.
With an approbiate 200 A type gG fuse the device can be used in a network with a prospective current of up to 100 kA.
3/18 | ABB
MS450, MS495, MS497 manual motor starters
Technical data
Connecting characteristics
Main circuit
Type MS450 MS495 MS497
Connecting capacity
Rigid 1 or 2 x 0.75 ... 16 mm² 2.5 ... 16 mm² 2.5 ... 16 mm²
Flexible with ferrule 1 x 0.75 ... 35 mm² 10 ... 70 mm² 10 ... 70 mm²
2 x 0.75 ... 25 mm² 10 ... 50 mm² 10 ... 50 mm²
Flexible 1 x 0.75 ... 35 mm² 10 ... 70 mm² 10 ... 70 mm²
2 x 0.75 ... 25 mm² 10 ... 50 mm² 10 ... 50 mm²
Stripping length 13 mm 17 mm 17 mm
Tightening torques 3 - 4.5 Nm / 27 … 40 Ib.in 4 - 6 Nm / 35 - 53 Ib.in 4 - 6 Nm / 35 - 53 Ib.in
Connection screw Pozidriv 2 Hexagon 4 Hexagon 4
1SYN829571C201
ABB | 3/19
MO450, MO495, MO496 manual motor starters magnetic only
32 to 100 A – with electromagnetic protection
MO450, MO495, MO496 manual motor starters magnetic only
32 to 100 A – with electromagnetic protection
Description
Description
The manualmotor
The manual motor starter
starter magnetic
magnetic only only is used
is used to manually
to manually switch
switch on onmotors
and off and offand
motors and them
to protect to
protect them
reliably and reliably
without the and
needwithout the
for a fuse fromneed for a fuse from short-circuits.
short-circuits.
Further features
Further featuresare
arethethe
build-in
build-indisconnect function,
disconnect trip-free
function, mechanism
trip-free and a rotary
mechanism andhandle withhandle
a rotary a
2 clear switch position indication. The manual motor starter magnetic only is suitable for three- and single-
with
phasea applications.
clear switchTheposition
handleindication. The
is lockable to manual
protect motor
against starter magnetic
unauthorized changes.only is suitable
Auxiliary for
contacts,
three- and single-phase applications.
releases,The handle is lockable busbars,
to protect against unauthorized
2CDC241004F0009
signalling contacts, undervoltage shunt trips, three-phase power in-feed blocks are
3 available asAuxiliary
changes. accessory.contacts, signalling contacts, undervoltage releases, shunt trips, three-
phase busbars, power in-feed blocks are available as accessory.
ST02501
55
30 100
63 25 25 1235.00
819.00 MO495-100
MO495-63 1SAM560000R1010
1SAM560000R1007 2.292
2.244
37 75 motor starter
MO496 manual 25 magnetic only 975.00 MO495-75 1SAM560000R1008 2.247
MO495-75 45
15 3290 50 25 1170.00
416.00 MO495-90
MO496-32 1SAM560000R1009
1SAM590000R1004 2.269
2.208
18.5
55 40100 50 25 520.00
1235.00 MO496-40
MO495-100 1SAM590000R1005
1SAM560000R1010 2.218
2.292
22 50 50 650.00 MO496-50 1SAM590000R1006 2.218
MO496 manual motor starter magnetic only
30 63 50 819.00 MO496-63 1SAM590000R1007 2.248
15 32 50 416.00 MO496-32 1SAM590000R1004 2.208
37 75 50 975.00 MO496-75 1SAM590000R1008 2.278
18.5
45 9040 50 50 520.00
1170.00 MO496-40
MO496-90 1SAM590000R1005
1SAM590000R1009 2.218
2.266
22
55 50
100 50 50 650.00
1235.00 MO496-50
MO496-100 1SAM590000R1006
1SAM590000R1010 2.218
2.293
30
(1) For overload 63 50 an appropriate 819.00
protection of motors, thermal or electronicMO496-63
overload relay must be1SAM590000R1007
used. 2.248
37 75 50 975.00 MO496-75 1SAM590000R1008 2.278
45 90 50 1170.00 MO496-90 1SAM590000R1009 2.266
55 100 50 1235.00 MO496-100 1SAM590000R1010 2.293
2CDC241021F0011
(1) For overload protection of motors, an appropriate thermal or electronic overload relay must be used.
MO496-100
45 1.77"
165 6.50"
125 4.92"
116 4.57"
150 5.91"
45 1.77"
85 3.35"
130 5.12"
140 5.51"
1SYN829571C201
2CDC242015F0011
2CDC242016F0011
2CDC131038C0201
MO450
MO450 MO495,
MO495,MO496
MO496
2/28 || ABB
3/20 ABB
MO450, MO495, MO496 manual motor starters magnetic only
Technical data
MO496-32: No need for back-up fuse in networks with a prospective current of up to 100 kA at 440 V.
MO496-90: No need for back-up fuse in networks with a prospective current of up to 70 kA at 440 V.
With an approbiate 200 A type gG fuse the device can be used in a network with a prospective current of up to 100 kA.
ABB | 3/21
MO450, MO495, MO496 manual motor starters magnetic only
Technical data
Connecting characteristics
Main circuit
Type MO450 MO495 MO496
Connecting capacity
Rigid 1 or 2 x 0.75 ... 16 mm² 2.5 ... 16 mm² 2.5 ... 16 mm²
Flexible with ferrule 1 x 0.75 ... 35 mm² 10 ... 70 mm² 10 ... 70 mm²
2 x 0.75 ... 25 mm² 10 ... 50 mm² 10 ... 50 mm²
Flexible 1 x 0.75 ... 35 mm² 10 ... 70 mm² 10 ... 70 mm²
2 x 0.75 ... 25 mm² 10 ... 50 mm² 10 ... 50 mm²
Stripping length 13 mm 17 mm 17 mm
Tightening torques 3 - 4.5 Nm / 27 … 40 Ib.in 4 - 6 Nm / 35 - 53 Ib.in 4 - 6 Nm / 35 - 53 Ib.in
Connection screw Pozidriv 2 Hexagon 4 Hexagon 4
1SYN829571C201
3/22 | ABB
MS45x, MS49x, MO45x, MO49x manual motor starters
Main accessories
2CDC242025F0011
MO45x and MO49x manual motor starters with accessories
1SYN829571C201
2CDC242025F0011
ABB | 3/23
MS45x, MS49x, MO45x, MO49x manual motor starters
Main accessories
Description
2CDC241026F0011
Manual motor starters can be equipped with auxiliary contacts for lateral/front mounting,
signalling contact for lateral mounting, undervoltage release and shunt trips. The accessories
can be fitted wiring free and without tools. A variety of combinations is possible as required for
HK4-11 the application. The auxiliary contacts change position with the main contacts. Undervoltage
release are used for remote tripping of the manual motor starter especially for emergency stop
circuits. Shunt trips release the MMS used for remote tripping.
3 Ordering details
Suitable Auxiliary Auxiliary Description Type Order code Pkg Weight
for contacts contacts qty (1 pce)
2CDC241022F0011
N.O. N.C.
kg
Auxiliary contacts – mountable on the front
MS45x, 1 1 HK4-11 1SAM401901R1001 10 0.017
HKS4-20 Changeover HK4-W 1SAM401901R1002 10 0.015
MS49x,
MO45x,
MO49x
Auxiliary contacts – mountable on the left
MS45x, 1 1 Max. 1 piece HKS4-11 1SAM401902R1001 2 0.045
MS49x, 2 0 Max. 1 piece HKS4-20 1SAM401902R1002 2 0.045
MO45x, 0 2 Max. 1 piece HKS4-02 1SAM401902R1003 2 0.045
2CDC241024F0011
MO49x
Signalling contacts – mountable on the left
MS45x, 2 2 Separate signalling acc. SK4-11 1SAM401904R1001 1 0.093
MS49x, UL508E 1 N.O.
SK4-11
MO45x, + 1 N.C. for short circuit
MO49x alarm and 1 N.O. + 1
N.C. for tripped alarm,
max. 1x SK4-11 +
1 x HKS4-xx
Suitable Rated control supply Frequency Type Order code Pkg Weight
2CDC241023F0011
V Hz kg
Shunt trip units – mountable on the right
AA4-24 MS45x, 20...24 50/60 AA4-24 1SAM401907R1001 1 0.135
MS49x, 90...110 50/60 AA4-110 1SAM401907R1002 1 0.135
MO45x, 200...240 50/60 AA4-230 1SAM401907R1003 1 0.128
MO49x 350...415 50/60 AA4-400 1SAM401907R1004 1 0.125
UA4-110
1SYN829571C201
3/24 | ABB
MS45x, MS49x, MO45x, MO49x manual motor starters
Main accessories
Connecting characteristics
Auxiliary circuit
Type HK4-11 HK4-W HKS4 SK4
Connecting capacity
Rigid 1 x 0.5... 2.5 mm²
2 x 0.5 ... 1.5 mm² or 0.75 ... 2.5 mm
Flexible with ferrule 1 x 0.5 ... 2.5 mm²
2 x 0.5 ... 1.5 mm² or 0.75 ... 2.5 mm
Stripping length 10 mm
Tightening torques 0.8 ... 1.2 Nm / 7 ... 10.3 Ib.in
Connection screw Pozidriv 2
ABB | 3/25
MS116, MS132, MO132, MS4xx, MO4xx manual motor starters
General accessories
Description
With this solution of door coupling rotary mechanism it is possible to operate a Manual Motor
Starter in the back of a switch cabinet from outside. The door coupling mechanism prevents
2CDC241003F0011
opening of the door of a switch cabinet with the Manual Motor Starter in ON position.
The complete mechanism includes handle, shaft, driver, shaft alignment ring and shaft
supporter.
MSHD-LB
3 All accessories fit for 6 mm shafts with a maximum length of 180 mm. The degree of
protection for handles MSHD is IP64.
Ordering details
Suitable Description Shaft Color Type Order code Pkg Weight
2CDC241002S0011
MO4xx
IP64 handles (UL: Type 1, 3R, 12)
MS116, Padlockable max. 3 padlocks Black MSHD-LB (1) 1SAM201920R1001 1 0.065
MS132, with bail diameter 5 … 8 mm, Yellow MSHD-LY (1) 1SAM201920R1002 1 0.065
MSMN
MO132, door interlock in ON position Black MSHD-LTB (2) 1SAM201920R1011 1 0.065
MS4xx, defeatable, for use with 6 mm Yellow MSHD-LTY (2) 1SAM201920R1012 1 0.065
Driver
MS116, Coupling driver for use with MSMN (3) 1SAM101923R0002 1 0.002
MS132, 6 mm OXS6… types up to 180 MSMNO (4) 1SAM101923R0012 1 0.002
3/26 | ABB
MS116, MS132, MO132, MS4xx, MO4xx manual motor starters
General accessories
1SYN829571C201
ABB | 3/27
4
1SYN829571C201
4/0 | ABB
Overload relays
Overview 4/2
TA42DU-M (18 … 42 A)
4
Ordering details 4/3
Technical data 4/4
ABB | 4/1
Overload relays
Thermal overload relay E16DU, E45DU, E80DU, E140DU electronic overload rela
0.10 to 140 A
Description
The E16DU up to E140DU are self-supplied electronic overload relays, which means no ex
supply is needed. It offers reliable protection for motors in the event of overload or phase
use like a thermal overload relay and compatible with standard motor applications, the ele
relay is convincing, above all, due to its wide setting range, high accuracy, high operation
2CDC231001F0007
range and the possibility to select a trip class (10E, 20E, 30E). Further features are the tem
compensation, trip contact (N.C.), signal contact (N.O.), automatic or manual reset select
mechanism, STOP and TEST function and a trip indication. The overload relays are conne
4 Type TA25DU-M TA42DU-M TA75DU-M TA80DUthe contactors. Single
TA110DU TA200DU
mounting kits are available as accessory.
E16DU-1.0
Ordering details
Current range 0.10 … 32 A 18 ... 42 A 18 ... 80 A 29 ... 80 A 66 ... 110 A 66 ... 200 A
Setting range Short-circuit Trip class Type Order code
protective device
Trip class 10A 10A 10A 10A A 10A 10A
Single mounting kit DB25 DB80 DB80 DB80 E16DU electronic DB200
overload relays DB200
0.10 … 0.32 1 A, Fuse type gG 10E, 20E, 30E E16DU-0.32 1SAX111001R1101
For contactors AX09 ... AX32 AX32 ... AX40 AX50 ... AX80 AX95 ... 0.30
AX150… 1.00 AX95
4 A, Fuse...
typeAX150
gG 10E, 20E, 30EAX185E16DU-1.0
... AX205 1SAX111001R1102
0.80 … 2.70 10 A, Fuse type gG 10E, 20E, 30E E16DU-2.7 1SAX111001R1103
2CDC231002F0006
1.90 … 6.30 20 A, Fuse type gG 10E, 20E, 30E E16DU-6.3 1SAX111001R1104
5.70 … 18.9 50 A, Fuse type gG 10E, 20E, 30E E16DU-18.9 1SAX111001R1105
E45DU electronic overload relays
9.00 … 30.0 160 A, Fuse type gG 10E, 20E, 30E E45DU-30 1SAX211001R1101
E45DU-30 15.0 … 45.0 160 A, Fuse type gG 10E, 20E, 30E E45DU-45 1SAX211001R1102
Electronic overload relay E80DU electronic overload relay
27.0 ... 80.0 A 250 A 10E, 20E, 30E E80DU-80 1SAX311001R1101
E140DU electronic overload relay
50.0 ... 140.0 A 400 A 10E, 20E, 30E E140DU-140 1SAX321001R1101
Main dimensions
2CDC231003F0006
mm, inches
43.7 1.72"
37 1.46"
66.4 2.61"
8 0.32"
14 0.55"
42 1.65"
26.5 1.04"
8 0.32"
18 0.71"
15 0.59"
E80DU-80 9.3 0.37" 9.3 0.37"
2,4 0.37" 36.3 1.43"
3 0.12"
1.2 0.5"
38.4 1.51"
Type E16DU E45DU E80DU E140DU EF205 EF370
94.2 3.71"
74.2 2.92"
85.2 3.35"
74.6 2.94"
Current range 0.10 … 18.9 A 9 ... 45 A 27 ... 80 A 50 ... 140 A 63 ... 210 A 115 ... 380 A
2CDC232007F0011
E16DU E80DU
For contactors AX09 ... AX18 AX32 ... AX40 AX50 ... AX115 AX150 AX185 ... AX205 AX205 ... AX370
E140DU-140 76 2.30"
59.7 2.35"
37 1.46"
67.6
13 0.51"
2 0.08" 17 0.67"
49 1.93"
6.8 0.27"
4 0.16" 59.4 2.39" 2.5 0.10"
5.5 0.21"
27.3 1.07"
18 0.71"
15 0.59"
2 0.08"
3 0.12"
9.6 0.38"
36 1.42"
14 0.55"
23.6 0.93"
8 0.12"
38.4 1.51"
94.2 3.71"
74.2 2.92"
29.2 1.15"
38.4 1.51"
85.2 3.35"
53.5 2.11"
61 2.40"
2CDC232009F0011
E45DU E140DU
1SYN829571C201
4/2 | ABB
Thermal overload relays TA25DU-M / TA42DU-M / TA75DU-M
0.10 to 80 A
Description
The TA25DU-M / TA42DU-M and TA75DU-M thermal overload relays are economic
electromechanical protection devices for the main circuit. They offer reliable protection for
motors in the event of overload or phase failure. The devices have trip class 10A.
2CDC231019F0013
The thermal overload relays are three pole relays with bimetal tripping elements. The motor
current flows through the bimetal tripping elements and heats them directly and indirectly. In
TA25DU-M
case of an overload (over current), the bimetal elements bent as a result of the heating. This
leads to a release of the relay and a change of the contacts switching position (95-96 / 97-98).
– Manual or automatic reset selectable
– Phase loss sensitive acc. to IEC/EN 60947-4-1
4
– Two electrically isolated auxiliary contacts – 1 N.O. + 1 N.C.
– TEST and STOP function – Trip indication on the front
– Temperature compensation
– Suitable for three- and single-phase applications
Ordering details
Setting range Short-circuit Trip Type Order code Weight
protective device class (1 pce)
A kg
TA25DU-M
0.10 ... 0.16 0.50 A, Fuse type F 10A TA25DU-0.16M 1SAZ211201R2005 0.150
0.16 ... 0.25 0.63 A, Fuse type F 10A TA25DU-0.25M 1SAZ211201R2009 0.150
0.25 ... 0.40 1.25 A, Fuse type F 10A TA25DU-0.4M 1SAZ211201R2013 0.150
0.40 ... 0.63 2 A, Fuse type gG / - 10A TA25DU-0.63M 1SAZ211201R2017 0.150
0.63 ... 1.00 4 A, Fuse type gG / 2 A aM 10A TA25DU-1.0M 1SAZ211201R2021 0.150
1.00 ... 1.40 6 A, Fuse type gG / 2 A aM 10A TA25DU-1.4M 1SAZ211201R2023 0.150
1.30 ... 1.80 6 A, Fuse type gG / 4 A aM 10A TA25DU-1.8M 1SAZ211201R2025 0.150
1.70 ... 2.40 6 A, Fuse type gG / 4 A aM 10A TA25DU-2.4M 1SAZ211201R2028 0.150
2.20 ... 3.10 10 A, Fuse type gG / 6 A aM 10A TA25DU-3.1M 1SAZ211201R2031 0.150
2.80 ... 4.00 10 A, Fuse type gG / 6 A aM 10A TA25DU-4.0M 1SAZ211201R2033 0.150
3.50 ... 5.00 16 A, Fuse type gG / 10 A aM 10A TA25DU-5.0M 1SAZ211201R2035 0.150
4.50 ... 6.50 20 A, Fuse type gG / 16 A aM 10A TA25DU-6.5M 1SAZ211201R2038 0.150
6.00 ... 8.50 20 A, Fuse type gG / 20 A aM 10A TA25DU-8.5M 1SAZ211201R2040 0.150
7.50 ... 11.00 35 A, Fuse type gG / 25 A aM 10A TA25DU-11M 1SAZ211201R2043 0.150
10.00 ... 14.00 35 A, Fuse type gG / 25 A aM 10A TA25DU-14M 1SAZ211201R2045 0.150
13.00 ... 19.00 50 A, Fuse type gG / 35 A aM 10A TA25DU-19M 1SAZ211201R2047 0.170
18.00 ... 25.00 63 A, Fuse type gG / 50 A aM 10A TA25DU-25M 1SAZ211201R2051 0.170
24.00 ... 32.00 80 A, Fuse type gG / 63 A aM 10A TA25DU-32M 1SAZ211201R2053 0.200
2CDC231020F0013
TA42DU-M
18 ... 25 63 A, Fuse type gG / 50 A aM 10A TA42DU-25M 1SAZ311201R2001 0.335
22 ... 32 80 A, Fuse type gG / 63 A aM 10A TA42DU-32M 1SAZ311201R2002 0.335
29 ... 42 100 A, Fuse type gG / 80 A aM 10A TA42DU-42M 1SAZ311201R2003 0.335
TA42DU-M
TA75DU-M
18 ... 25 63 A, Fuse type gG / 50 A aM 10A TA75DU-25M 1SAZ321201R2001 0.335
22 ... 32 80 A, Fuse type gG / 63 A aM 10A TA75DU-32M 1SAZ321201R2002 0.335
29 ... 42 100 A, Fuse type gG / 80 A aM 10A TA75DU-42M 1SAZ321201R2003 0.335
2CDC231022F0013
1SYN829571C201
ABB | 4/3
Thermal overload relays TA25DU-M / TA42DU-M / TA75DU-M
Technical data
2CDC232005F0211
2CDC232005F0211
4/4 | ABB
Thermal overload relays TA25DU-M / TA42DU-M / TA75DU-M
Technical data
Electrical connection
Main circuit
Type TA25DU-M TA25DU-M TA25DU-M
(0.16-11 A) (14-25 A) (32 A)
Connecting capacity
Rigid 1x 0.75 ... 4 mm² 1.5 ... 6 mm² 1.5 ... 10 mm²
2x 0.75 ... 4 mm² 1.5 ... 6 mm² -
Flexible with insulated ferrule 1 x or 2 x1) 0.75 ... 4 mm² 1.5 ... 4 mm² 1.5 ... 6 mm²
Stripping length 12 mm 12 mm 15 mm
Tightening torques 1.4 - 2.0 Nm 1.4 - 2.0 Nm 2.5 - 3.2 Nm
Connection screw M4 (Pozidriv 2) M4 (Pozidriv 2) M5 (Pozidriv 2)
1)
Combination of different wires not possible
Main circuit
Type TA42DU-M TA75DU-M
Connecting capacity
Rigid 1 x 2.5 ... 25 mm²
2 x 2.5 ... 16 mm²
Flexible with insulated ferrule 1 x 2.5 ... 25 mm²
2 x 2.5 ... 10 mm²
Stripping length 14 mm
Tightening torques 4.5 Nm
Connection screw M6 (Pozidriv 2)
Auxiliary circuit
Type TA25DU-M TA42DU-M TA75DU-M
Connecting capacity
Rigid 1 x or 2 x 0.75 ... 4 mm²
Flexible 1 x or 2 x 0.75 ... 2.5 mm²
Stripping length 9 mm
Tightening torques 0.8 ... 1.3 Nm
Connection screw M3.5 (Pozidriv 2)
1SYN829571C201
ABB | 4/5
Thermal overload relays TA25DU-M / TA42DU-M / TA75DU-M
Accessories
Description
The single mounting kits offer the possibility to mount the overload relays separately from the
contactor.
SST01494
The DS25-A allows electrically remote tripping of TA25DU-M. DR25-A coil for remote reset of
TA25DU-M.
DX25
Ordering details
For thermal overload relays Description Type Order code Weight
(1 pce)
4 kg
2CDC231017F0006
The coil is not suitable for Continuous operation. Impulse duration: maximum 0.2 seconds.
DR25-A-220/380
1SFC151402F0001
KPR-101L
2CDC231007F0010
DB80
1SYN829571C201
4/6 | ABB
Thermal overload relays TA80DU / TA110DU / TA200DU
29 to 200 A
Description
The TA80DU thermal overload relays are economic electromechanical protection devices for
the main circuit. They offer reliable protection for motors in the event of overload or phase
2CDC231008F0011
Ordering details
Setting range Short-circuit Trip class Type Order code Weight
TA200DU protective device (1 pce)
A kg
TA80DU
29 ... 42 100 A, Fuse type gG / 80 A aM 10A TA80DU-42 1SAZ331201R1003 0.360
36 ... 52 125 A, Fuse type gG / 100 A aM 10A TA80DU-52 1SAZ331201R1004 0.365
45 ... 63 160 A, Fuse type gG / 125 A aM 10A TA80DU-63 1SAZ331201R1005 0.365
60 ... 80 200 A, Fuse type gG / 160 A aM 10A TA80DU-80 1SAZ331201R1006 0.375
TA110DU
66 ... 90 200 A, Fuse type gG / 160 A aM 10A TA110DU-90 1SAZ411201R1001 0.750
80 ... 110 224 A, Fuse type gG / 200 A aM 10A TA110DU-110 1SAZ411201R1002 0.755
TA200DU
66 ... 90 200 A, Fuse type gG / 125 A aM 10A TA200DU-90 1SAZ421201R1001 0.755
80 ... 110 224 A, Fuse type gG / 160 A aM 10A TA200DU-110 1SAZ421201R1002 0.760
100 ... 135 224 A, Fuse type gG / 200 A aM 10A TA200DU-135 1SAZ421201R1003 0.760
2CDC231007S0010
110 ... 150 250 A, Fuse type gG / 200 A aM 10A TA200DU-150 1SAZ421201R1004 0.760
130 ... 175 315 A, Fuse type gG / 250 A aM 10A TA200DU-175 1SAZ421201R1005 0.770
150 ... 200 315 A, Fuse type gG / 250 A aM 10A TA200DU-200 1SAZ421201R1006 0.785
DB80
ABB | 4/7
Thermal overload relays TA80DU / TA110DU / TA200DU
Technical data
2CDC232005F0211
2CDC232005F0211
1SYN829571C201
ta: Motor starting time - TA80DU t a: Motor starting time - TA110DU ta: Motor starting time - TA200DU
4/8 | ABB
Thermal overload relays TA80DU / TA110DU / TA200DU
Technical data
Electrical connection
Main circuit
Type TA80DU TA110DU TA200DU
Connecting capacity
Rigid 1 x 2.5 ... 25 mm² 16 ... 35 mm² 25 ... 120 mm²
2 x 2.5 ... 16 mm² - -
Flexible 1 x 2.5 ... 25 mm² 16 ... 35 mm² 16 ... 35 mm²
2 x 2.5 ... 10 mm² - -
Lugs - - L ≤ 12mm / I > 6mm
Stripping length 14 mm 25 mm -
Tightening torques 4.5 Nm / 40 Ib.in 7.2 ... 9.6 Nm / 40 lb.in 4 Nm
Connection screw M6 (Pozidriv 2) M8 (Hexagon) M6
Auxiliary circuit
Type TA80DU TA110DU TA200DU
Connecting capacity
Rigid 1 x or 2 x 0.75 ... 4 mm²
Flexible with ferrule 1 x or 2 x 0.75 ... 2.5 mm²
Flexible with insulated ferrule 1 x or 2 x 0.75 ... 2.5 mm²
Flexible 1 x or 2 x 0.75 ... 2.5 mm²
Stripping length 9 mm
Tightening torques 0.8 ... 1.3 Nm / 12 Ib.in
Connection screw M3.5 (Pozidriv 2)
1SYN829571C201
ABB | 4/9
Thermal overload relays TA25DU-M / TA42DU -M / TA75DU -M
Dimensions
2CDC232024F0011
2CDC232023F0011
TA25DU-M DB25
TA42DU-M
2CDC232017F0011
2CDC232025F0011
1SYN829571C201
TA75DU-M DB80
4/10 | ABB
Thermal overload relays TA80DU / TA110DU / TA200DU
Dimensions
2CDC232018F0011
2CDC232025F0011
4
TA110DU
2CDC232021F0011
1SYN829571C201
TA200DU
ABB | 4/11
Electronic overload relays E16DU, E45DU, E80DU, E140DU
0.10 to 140
E16DU, A E80DU, E140DU electronic overload relays
E45DU,
0.10 to 140 A
Description
Description
The E16DU
The E16DUupuptoto E140DU
E140DU are are
self-supplied electronic
self-supplied overload
electronic relays, which
overload relays,means
which nomeans
extra external
no extra
supply is needed. It offers reliable protection for motors in the event of overload or phase failure. Easy to
external supply is needed. It offers reliable protection for motors in the event of overload or
use like a thermal overload relay and compatible with standard motor applications, the electronic overload
phase
relay is failure. Easy
convincing, to use
above all, like
due atothermal
its wide overload relayhigh
setting range, andaccuracy,
compatiblehigh with standard
operational motor
temperature
2CDC231001F0007
A kg
1.90 … 6.30 20 A, Fuse type gG 10E, 20E, 30E E16DU-6.3 1SAX111001R1104 0.150
5.70 … 18.9
E16DU 50 A, Fuse relays
electronic overload type gG 10E, 20E, 30E E16DU-18.9 1SAX111001R1105 0.150
6
0.10 … 0.32 1 A, Fuse
E45DU electronic overload relays type gG 10E, 20E, 30E E16DU-0.32 1SAX111001R1101 0.150
0.30
9.00 ……30.0
1.00 4 A,A,Fuse
160 Fuse type gG 10E, 20E,
type gG 10E,30E20E, 30EE45DU-30
E16DU-1.01SAX211001R1101
1SAX111001R1102 0.150
0.350
E45DU-30 0.80
15.0 ……45.0
2.70 10
160 A, Fusetype
A, Fuse type
gGgG10E, 20E,
10E,30E20E, 30EE45DU-45
E16DU-2.71SAX211001R1102
1SAX111001R1103 0.150
0.350
E45DU
1.90
E80DU … electronic
6.30 20 A, Fuse
overload type gG
relay 10E, 20E, 30E E16DU-6.3 1SAX111001R1104 0.150
5.70 … 18.9
27.0 ... 80.0 A 50 A,
250 A Fuse type gG 10E,
10E, 20E, 30E20E, 30E E16DU-18.9
E80DU-80 1SAX111001R1105
1SAX311001R1101 0.150
0.770
E140DU electronic overload relay
E45DU electronic
50.0 ... 140.0 A overload
400 A relays 10E, 20E, 30E E140DU-140 1SAX321001R1101 0.915
9.00 … 30.0 160 A, Fuse type gG 10E, 20E, 30E E45DU-30 1SAX211001R1101 0.350
15.0 ... 45.0 160 A, Fuse type gG 10E, 20E, 30E E45DU-45 1SAX211001R1102 0.350
Main dimensions
2CDC231003F0006
mm, inches
43.7 1.72"
27.0 ... 80.0 A 250 A 10E, 20E, 30E E80DU-80 1SAX311001R1101 0.770
14 0.55"
42 1.65"
26.5 1.04"
8 0.32"
18 0.71"
15 0.59"
1.2 0.5"
50.0 ... 140.0 A 400 A 10E, 20E, 30E E140DU-140 1SAX321001R1101 0.915
38.4 1.51"
94.2 3.71"
74.2 2.92"
85.2 3.35"
74.6 2.94"
2CDC232007F0011
2CDC232010F0011
2CDC231004F0006
E16DU E80DU
E140DU-140 76 2.30"
2 0.08" 17 0.67"
49 1.93"
6.8 0.27"
4 0.16" 59.4 2.39" 2.5 0.10"
5.5 0.21"
27.3 1.07"
18 0.71"
15 0.59"
2 0.08"
3 0.12"
9.6 0.38"
36 1.42"
14 0.55"
23.6 0.93"
8 0.12"
38.4 1.51"
94.2 3.71"
74.2 2.92"
29.2 1.15"
38.4 1.51"
85.2 3.35"
53.5 2.11"
61 2.40"
2CDC232009F0011
2CDC232008F0011
1SYN829571C201
2CDC107030C0201
E45DU E140DU
ABB | 6/39
4/12 | ABB
E16DU, E45DU, E80DU, E140DU electronic overload
Technical
Electronic data relays E16DU, E45DU, E80DU, E140DU
overload
Technical data
120
switching frequency
100
ta =
80
0.5
ta
2CDC232005F0211
60
=
1
ta =
s
1.5
40 ta = s
3s
2CDC232005F0211
20 ta = 5
s
1SYN829571C201
0
0 20 40 60 80 100 (%)
duty ratio
ta: Motor starting time
t a: Motor starting time
ABB | 4/13
E16DU, E45DU, E80DU, E140DU electronic overload relays
Technical data
Electrical connection
Main circuit
Type E16DU E45DU E80DU E140DU
Connecting capacity
Rigid 1 x 1 ... 4 mm² 2.5 ... 16 mm² 6 ... 95 mm² 6 ... 95 mm²
2 x 1 ... 4 mm² 2.5 ... 16 mm² 6 ... 35 mm² 6 ... 35 mm²
Flexible with insulated ferrule 1 x 0.75 ... 2.5 mm² 2.5 ... 10 mm² 6 ... 70 mm² 6 ... 70 mm²
2 x 0.75 ... 2.5 mm² 2.5 ... 10 mm² 6 ... 35 mm² 6 ... 35 mm²
Stripping length 9 mm 13 mm - -
Tightening torques 0.8 - 1.5 Nm / 7 2.3 - 2.6 Nm / 22 6 - 6.5 Nm / 53 Ib.in 6 - 6.5 Nm / 53 Ib.in
Ib.in Ib.in
Connection screw M3.5 (Pozidriv 2) M5 (Pozidriv 2) M8 (inbus 4) M8 (inbus 4)
Auxiliary circuit
Type E16DU E45DU E80DU E140DU
Connecting capacity
Rigid 1 x or 2 x 1 ... 4 mm²
Flexible with ferrule 1 x or 2 x 0.75 ... 2.5 mm²
Flexible with insulated ferrule 1 x or 2 x 0.75 ... 2.5 mm²
Flexible 1 x or 2 x 0.75 ... 2.5 mm²
Stripping length 9 mm
Tightening torques 0.8 ... 1.2 Nm / 7 Ib.in
Connection screw M3.5 (Pozidriv 2)
1SYN829571C201
4/14 | ABB
E16DU, E45DU, E80DU, E140DU electronic overload relays
Accessories
E16DU, E45DU, E80DU, E140DU electronic overload relays
Accessories
Description
Description
Single
Single mounting
mounting kitsavailable
kits are are available as accessory
as accessory for E45DU,
for E16DU, E16DU,E80DU,
E45DU, andE80DU,
E140DU.and
TheE140DU.
single
mounting kits offer
The single the possibility
mounting to mount
kits offer the overload
the possibility relay separately
to mount from the
the overload contactor.
relay separately from the
2CDC231003F0010
contactor.
Ordering details
For thermal overload Description Type Order code Weight
DB16E Ordering details
Forrelays
electronic overload relays Description Type Order code (1 pce)
Weight
Single mounting kits kg
(1 pce)
E16DU Single mounting kit DB16E 1SAX101110R0001 kg 0.035 4
E45DU
Single mounting kits Single mounting kit DB45E 1SAX201110R1001 0.090
E80DU
E16DU Single
Single mounting
mounting kit kit DB80E
DB16E 1SAX301110R1001
1SAX101110R0001 0.145
0.035
E140DU
E45DU Single
Single mounting
mounting kit kit DB140E
DB45E 1SAX301110R1002
1SAX201110R1001 0.145
0.090
E80DU Single mounting kit DB80E 1SAX301110R1001 0.145
2CDC231004F0010
6
Main dimensions mm, inches
69.5 2.74"
65.2 2.57"
64.5 2.54"
2CDC231005F0010
14.5 0.57"
102.5 4.04"
113 4.45"
125.5 4.94"
29.6 1.17" 4.2 0.17"
61 2.40"
82.6 3.25"
91 3.59"
4.2 0.17"
50 1.97"
57 2.44"
51 2.01"
64.4 2.54"
41.7 1.64"
35.7 1.41"
3 0.12"
20.2 0.80"
DB80E
2CDC232030F0011
2CDC232027F0011
4.8 0.19"
14 0.55" 14 0.55"
12.5 0.49"
5.5 0.22"
14 0.55" 14 0.55" 5.5 0.22" 35 1.38"
10.5 0.41"
45 1.77"
94.2 3.70"
44.3 1.74" 68.5 2.70"
95.6 3.76"
DB16E DB45E
2CDC231006F0010
99 3.90"
81.5 3.21"
33.7 1.33"
99 3.90"
37 1.46"
33.7 1.33"
37 1.46"
5.5 0.22" 4.3 0.17" 5.5 0.22"
4.3 0.17"
94.2 3.71"
85.2 3.35"
85.2 3.35"
68.5 2.70"
68.5 2.70"
62.5 2.46"
62.5 2.46"
21.1 0.83"
2CDC232028F0011
2CDC232029F0011
21.1 0.83"
5 0.20"
DB80E DB140E
1SYN829571C201
2CDC107030C0201
ABB | 6/43
ABB | 4/15
EF205, EF370 electronic overload relays
63 to 380 A
Description
The EF205 and EF370 are self-supplied electronic overload relays, which means no extra
external supply is needed. It offers reliable protection for motors in the event of overload or
phase failure. Easy to use like a thermal overload relay and compatible with standard motor
2CDC231010V0012
applications, the electronic overload relay is convincing, above all, due to its wide setting
range, high accuracy, high operational temperature range and the possibility to select a trip
class (10E, 20E, 30E). Further features are the temperature compensation, trip contact (N.C.),
signal contact (N.O.), automatic or manual reset selectable, trip-free mechanism, STOP
EF205-210 and TEST function and a trip indication. The overload relays are connected directly to the
4 contactors.
Ordering details
Setting range Short-circuit Trip class Type Order code Weight
protective device (1 pce)
2CDC231013V0012
A kg
63 ... 210 1250 A, Fuse 10E, 20E, 30E EF205-210 1SAX531001R1101 1.210
type gG
115 ... 380 1600 A, Fuse 10E, 20E, 30E EF370-380 1SAX611001R1101 1.430
type gG
EF370-380
KPR-101L
1SYN829571C201
4/16 | ABB
EF205, EF370 electronic overload relays
Technical data
1SYN829571C201
ABB | 4/17
EF205, EF370 electronic overload relays
Technical data
General data
Type EF205, EF370
Pollution degree 3
Phase loss sensitive Yes
Ambient air temperature
Operation Open - compensated -25 ... +70 °C
Storage -50 ... +85 °C
Ambient air temperature compensation Acc. to IEC/EN 60947-4-1
Maximum operating altitude permissible 2000 m
Resistance to shock acc. to IEC 60068-2-27 25g / 11 ms
4 Resistance to vibrations acc. to IEC 60068-2-6 5g / 3 … 150 Hz
Mounting position Position 1-6
Mounting Mount on the contactor and tighten the screws of the main circuit terminals
Degree of protection Housing IP20
Main circuit terminals IP20
Electrical connection
Main circuit
Type EF205 EF370
Connecting capacity
Rigid 1 x 16 ... 185 mm² 50 ... 240 mm²
2 x 16 ... 120 mm² 50 ... 150 mm²
Flexible 1 x 16 ... 185 mm² 50 ... 240 mm²
2 x 16 ... 120 mm² 50 ... 150 mm²
Lugs L ≤ 24 mm 32 mm
Bars Ø > 8 mm 10 mm
Stripping length - -
Tightening torques 18 Nm / 160 lb.in 28 Nm / 247 lb.in
Connection screw M8 M10
Auxiliary circuit
Type EF205, EF370
Connecting capacity
Rigid 1 or 2 x 1 ... 4 mm²
Flexible with ferrule 1 or 2 x 0.75 ... 2.5 mm²
Flexible with insulated 1 or 2 x 0.75 ... 2.5 mm²
ferrule
Flexible 1 or 2 x 0.75 ... 2.5 mm²
Stripping length 9 mm
Tightening torques 0.8 ... 1.2 Nm / 7 ... 11 Ib.in
Connection screw M3.5 (Pozidriv 2)
1SYN829571C201
4/18 | ABB
E16DU electronic overload relays
0.10 … 0.32 1 A, Fuse type gG 10E, 20E, 30E E16DU-0.32 1SAX111001R1101 0.150
0.30 … 1.00 4 A, Fuse type gG 10E, 20E, 30E E16DU-1.0 1SAX111001R1102 0.150
0.80 … 2.70 10 A, Fuse type gG 10E, 20E, 30E E16DU-2.7 1SAX111001R1103 0.150
mm, inches
43.7 1.72"
37 1.46"
66.4 2.61" 3 0.12"
8 0.32"
14 0.55"
42 1.65"
26.5 1.04"
8 0.32"
18 0.71"
15 0.59"
9.3 0.37" 9.3 0.37" 3 0.12"
2,4 0.37" 36.3 1.43"
1.2 0.5"
38.4 1.51"
DU, E45DU, E80DU, E140DU electronic overload relays
94.2 3.71"
74.2 2.92"
85.2 3.35"
74.6 2.94"
essories 4
2CDC232007F0011
2CDC232010F0011
2CDC231004F0006
Description
E16DU E80DU
Single mounting kits are available as accessory for E16DU, E45DU, E80DU, and E140DU. The single
0 76 2.30"
mounting kits offer the possibility to mount the overload relay separately from the contactor. 59.7 2.35"
2CDC231003F0010
37 1.46"
67.6 2.66" 5 0.20"
13 0.51"
2 0.08" 17 0.67"
49 1.93"
6.8 0.27"
4 0.16" 59.4 2.39" 2.5 0.10"
5.5 0.21"
27.3 1.07"
18 0.71"
15 0.59"
2 0.08"
3 0.12"
9.6 0.38"
36 1.42"
14 0.55"
23.6 0.93"
8 0.12"
Ordering details
38.4 1.51"
85.2 3.35"
(1 pce)
53.5 2.11"
61 2.40"
kg
Single mounting kits
2CDC232009F0011
2CDC232008F0011
2CDC107030C0201
E16DU 10.3 0.41" 5.7 0.22" 57 2.24"
Single mounting kit DB16E 16 0.63" 5.5 0.22" 1SAX101110R0001 3 0.12"
74.5 2.93"
0.035
37 1.46"
E140DU
E45DU Single mounting kit E140DU DB140E 1SAX301110R1002 0.145
6
Main dimensions mm, inches ABB | 6/39
98.5 3.88"
35 1.38" 90.2 3.55"
3 0.12"
5.5 0.22"
4.5 0.18"
69.5 2.74"
65.2 2.57"
64.5 2.54"
2CDC231005F0010
14.5 0.57"
102.5 4.04"
113 4.45"
125.5 4.94"
91 3.59"
4.2 0.17"
50 1.97"
57 2.44"
51 2.01"
64.4 2.54"
41.7 1.64"
35.7 1.41"
3 0.12"
20.2 0.80"
2CDC232030F0011
2CDC232027F0011
4.8 0.19"
14 0.55" 14 0.55"
12.5 0.49"
5.5 0.22"
14 0.55" 14 0.55" 5.5 0.22" 35 1.38"
10.5 0.41"
45 1.77"
94.2 3.70"
44.3 1.74" 68.5 2.70"
95.6 3.76"
DB16E DB45E
2CDC231006F0010
99 3.90"
81.5 3.21"
33.7 1.33"
99 3.90"
37 1.46"
33.7 1.33"
37 1.46"
5.5 0.22" 4.3 0.17" 5.5 0.22"
4.3 0.17"
94.2 3.71"
85.2 3.35"
85.2 3.35"
68.5 2.70"
68.5 2.70"
62.5 2.46"
62.5 2.46"
1SYN829571C201
21.1 0.83"
2CDC232028F0011
2CDC232029F0011
21.1 0.83"
5 0.20"
DB80E DB140E
ABB | 4/19
A kg
63 ... 210 1250 A, Fuse type gG 10E, 20E, 30E EF205-210 1SAX531001R1101 1.21
115 ... 380 1600 A, Fuse type gG 10E, 20E, 30E EF370-380 1SAX611001R1101 1.43
Electronic overload relays EF205, EF370
2CDC231013V0012
Dimensions
-380
10 0.39"
7.4 0.29" 17.9 0.7" 30 1.18" 5 0.2"
11 0.43"
5 0.2"
4
122 4.8"
151 5.9"
18.5 0.73"
2CDC232004F0012
10 0.39"
EF205-210
122.8 4.83"
11 0.43"
5 0.2"
6.4"
0.4'
163.6
122
0.9"
22.8
2CDC232005F0012
14 0.55"
EF370-380
BB
1SYN829571C201
4/20 | ABB
General technical data
1SYN829571C201
ABB | 5/1
Coordination with short-circuit protection devices
In compliance with standards IEC 60947-4-1, we define for the contactors and starters the type, rating and characteristics of
the short-circuit protection devices SCPD which allow selective protection against overloads and ensure protection against
short circuits.
Basic functions
Any starter is designed to:
–– start motors,
–– ensure continuous functioning of motors,
– – disconnect motors from the supply line,
– – guarantee protection of motors against overloads.
The starter is typically made up of a switching device (contactor) and an overload protection device (thermal overload relay or electronic
overload relay).
These two devices MUST be coordinated with equipment capable of providing protection against short circuit (SCPD: short circuit protective
5 device): typically a circuit breaker with magnetic release only or a switch fuse. These are not necessarily part of the starter.
Applicable standards
IEC 60947-4-1 (EN 60947-4-1) precisely defines the different points to be considered in order to carry out correct coordination.
Complete coordination for a combination includes the following points:
–– Selectivity test between the overload relay and the short-circuit protection device SCPD.
–– Short-circuit condition tests:
-- at prospective "r" currents - These currents depend on the rated operational current of the starter (Ie AC-3) and are given by the standard
(Table 13). For example:
r = 1kA for Ie AC-3 < 16 A
r = 3 kA for 16 A < Ie AC-3 < 63 A
r = 5 kA for 63 A < Ie AC-3 < 125 A etc.
-- at the rated conditional short-circuit current "Iq" - This is the maximum prospective current that the combination can withstand, for example 50
kA.
Types of coordination
IEC 60947-4-1 (EN 60947-4-1) defines two types of coordination according to the expected level of service continuity. Acceptable extreme
damage for the switchgear is divided into two types.
Type 1: In short-circuit conditions, the contactor or starter does not endanger persons or installations and will not be able to then operate
without being repaired or having parts replaced.
Type 2: In short-circuit conditions, the contactor or starter does not endanger persons or installations and will be able to operate afterwards.
The risk of contacts light welding is acceptable. In this case, the manufacturer must stipulate the measures to be taken with respect to
maintenance of the equipment.
The complete ABB offer
ABB has acquired years of experience with respect to problems of coordination and is able to make a complete offer based on tests performed
in its qualified laboratories. This offer includes 400 V, 500 V, 690 V networks.
A complete data base of coordination tables, according to IEC 60947-4-1 (EN 60947-4-1), is available on the ABB Website.
In the coordination tables the following short-circuit protection devices are recommended:
–– Moulded case circuit-breakers (MCCBs)
–– Miniature circuit-breakers (MCBs)
– – Switch-disconnector-fuses (aM, gG and BS)
– – Manual Motor Starters (MMS).
General remarks applicable to all tables
– – Each table is defined for a maximum ambient temperature of 40 °C. For higher temperatures, apply a derating factor according to the
following rules:
-- Fuses: factor of 0.8 applied to In for an ambient temperature of 70 °C
-- MCCBs and MCBs: factor of 0.8 applied to In for an ambient temperature of 60 °C
-- The starter derating factor depends on the operating conditions of thermal overload relays:
Factor of 0.9 applied to In for an ambient temperature of 70 °C.
– – Each table is defined for motor currents: 3-phase motors, 4-pole
– – Normal starting means a starting time < 2 s. - Difficult starting means an accelerating time 10 s < ts < 30 s
Tripping classes of thermal overload relays according to IEC 60947-4-1 (EN 60947-4-1): 10A and 10
Tripping classes of electronic overload relays according to IEC 60947-4-1 (EN 60947-4-1): 10E, 20E, 30E selectable
–– In the tables with MCCBs, these are fitted with the magnetic relay alone. Setting is always carried out at > 12.3 Ie AC-3 so that the transient
current peak occurring during starting does not lead to tripping.
1SYN829571C201
5/2 | ABB
Terms and technical definitions
Definitions according to SEMI F47-0706 Conventional free air thermal current Ith
Current that the contactor can withstand in free air for a duty time of
SEMIF47-0706 defines the voltage sag immunity required for
8 hours without the temperature rise of its various parts exceeding
semiconductor processing, metrology and automated test equipment,
the maximum values given by the standard.
and on subsystems and components which are used in the
construction of semiconductor processing equipment including but
not limited to: Operating cycle or cycle
– – Power supplies Includes one making operation and one breaking operation.
– – Generators
–– Robots and factory interface
Cycle time
–– Chillers, pumps, blowers
This is the sum of the current flow time and the no-current time for
–– AC operated contactors and contactor relays given cycle.
–– voltage sag: an rms reduction in the AC voltage, at the power
frequency, for durations from a half cycle to a few seconds.
Electrical durability
1SYN829571C201
The IEC terminology for this phenomenon is voltage dip. Number of on-load operating cycles that the contactor is able to carry
out. It depends on the operational current, the operational voltage
voltage sag immunity: the ability of equipment to withstand
and the utilization category.
momentary electrical power interruptions or sags
ABB | 5/3
Terms and technical definitions
Time
Assessed failure rate – – Time constant: Ratio of the inductance to the resistance
Defined according to IEC 60947-5-4. This rate is given in standard (L/R = mH/Ω = ms).
industrial environments for the contactor relays and for the built-in – – Short-time withstand current: Current that the contactor is able
auxiliary contact of contactors. to withstand in closed position for a short time interval and in
specified conditions.
– – Closing time: Time interval between the coil energization and the
Load factor
instant the contacts touch on all the poles.
Ratio of the on-load operating time to the total cycle time x 100.
– – Opening time: Time interval between the coil de-energization and
the instant the contacts separate on all the poles.
Switching frequency
5 Number of switching cycles per hour.
Rated control voltage Uc
Control voltage value for which the control circuit is sized.
Plugging
Stopping or fast reversal in rotation direction of a motor by two supply
leads being interchanged while the motor is running. Rated operational voltage Ue
Voltage to which the contactor's utilization characteristics refer. In
three-phase it is the phase-to-phase voltage.
Inching
Energization of a motor's circuit repeatedly or for short periods with
the aim of obtaining small movements of the driven mechanism. Rated insulation voltage Ui
Reference voltage for dielectric tests and creepage distances.
Mounting position
Comply with the manufacturer's instructions. Restrictions are to be Shock withstand
taken into account for certain mounting positions. Requirement for vehicles, crane drives, installations on board ships
and plug-in equipment. For the acceptable "g" values, the contacts
must not change position and the thermal overload relays must not
Rated breaking or making capacity trip.
Root mean square (r.m.s.) value of the current that the contactor is
able to break or make at a given voltage according to the conditions
specified by standards and for a given utilization category. Resistance to vibrations
Requirements for vehicles, boats and other means of transport. For
the specified vibration amplitude and frequency values the device
Intermittent duty must remain able to operate.
Duty during which the contactor is successively closed or open
for periods which are too short to enable the contactor to achieve
thermal balance.
1SYN829571C201
5/4 | ABB
Standards and utilization categories
Utilization categories:
A contactor's duty is characterised by the utilization category together with the rated operational voltage and current indicated.
In fact some applications, and the specific criteria characterizing the various loads controlled by contactors, may modify the utilization charac-
teristics of the contactors. The main applications concerned are:
Transformer switching
Account must be taken of the peaks due to magnetization phenomena when the current is made.
For this application, IEC publication 60947-4-1 stipulates utilization category AC-6a. The operational currents or powers acceptable for the
contactors are determined using the values obtained for AC-3 or AC-4 category tests and the calculating formula given in IEC 60947-4-1 (Table
9).
ABB | 5/5
Standards and utilization categories
Influence of the length of the conductors used in the contactor control circuit
According to the operational voltages, the cross-sectional areas, the coil consumption and the control layout, difficulties due to line resistances
5 and capacitances may appear during contactor closing and opening orders.
Key:
U (I) = applied voltage (current) T 0.95 = t ime required to reach 95% of the current in steady-state
Ur = recovery voltage conditions, expressed in milliseconds
1SYN829571C201
5/6 | ABB
Degrees of protection
General
In an installation, the degree of protection required for electrical equipment depends on the environmental characteristics. The degree of
protection, ensured by the enclosure of equipment or by the cubicle containing the equipment is expressed by the IP code which gives the level
of protection against access to hazardous parts, the ingress of foreign bodies and/or the ingress of water, in compliance with IEC 60529, IEC
60947-1.
Besides the IP symbol, the complete code has two figures followed (optionally) by two additional letters. A short description of the elements
used in IP coding is given below.
1SYN829571C201
ABB | 5/7
Notes
Notes
1SYN829571C201
1SYN829571C201
Type Order Code Page Type Order Code Page Type Order Code Page
AX09-30-10-81 1SBL901074R8110 2/3 AX50-30-11-80 1SBL351074R8011 2/6 VM19 1SFN030300R1000 2/13
AX09-30-01-81 1SBL901074R8101 2/3 AX50-30-11-86 1SBL351074R8611 2/6 VE5-1 1SBN030110R1000 2/13
AX09-30-10-88 1SBL901074R8810 2/3 AX65-30-11-81 1SBL371074R8111 2/6 VE5-2 1SBN030210R1000 2/13
AX09-30-01-88 1SBL901074R8801 2/3 AX65-30-11-88 1SBL371074R8811 2/6 TEF5-ON 1SBN020312R1000 2/14
AX09-30-10-84 1SBL901074R8410 2/3 AX65-30-11-84 1SBL371074R8411 2/6 TEF5-OFF 1SBN020314R1000 2/14
AX09-30-01-84 1SBL901074R8401 2/3 AX65-30-11-80 1SBL371074R8011 2/6 BEA16/116 1SBN081406R1000 2/14
AX09-30-10-80 1SBL901074R8010 2/3 AX65-30-11-86 1SBL371074R8611 2/6 BEA40/450 1SBN083206R1000 2/14
AX09-30-01-80 1SBL901074R8001 2/3 AX80-30-11-81 1SBL411074R8111 2/6 BEA50/450 1SBN083506R1000 2/14
AX09-30-10-86 1SBL901074R8610 2/3 AX80-30-11-88 1SBL411074R8811 2/6 BEA75/495 1SBN084106R1000 2/14
AX09-30-01-86 1SBL901074R8601 2/3 AX80-30-11-84 1SBL411074R8411 2/6 BEA100/495 1SBN084506R1000 2/14
AX12-30-10-81 1SBL911074R8110 2/3 AX80-30-11-80 1SBL411074R8011 2/6 RV5/50 1SBN050010R1000 2/14
AX12-30-01-81 1SBL911074R8101 2/3 AX80-30-11-86 1SBL411074R8611 2/6 RV5/133 1SBN050010R1001 2/14
AX12-30-10-88 1SBL911074R8810 2/3 AX95-30-11-81 1SFL431074R8111 2/7 RV5/250 1SBN050010R1002 2/14
AX12-30-01-88 1SBL911074R8801 2/3 AX95-30-11-88 1SFL431074R8811 2/7 RV5/440 1SBN050010R1003 2/14
AX12-30-10-84 1SBL911074R8410 2/3 AX95-30-11-84 1SFL431074R8411 2/7 RC5-1/50 1SBN050100R1000 2/14
AX12-30-01-84 1SBL911074R8401 2/3 AX95-30-11-80 1SFL431074R8011 2/7 RC5-1/133 1SBN050100R1001 2/14
AX12-30-10-80 1SBL911074R8010 2/3 AX95-30-11-86 1SFL431074R8611 2/7 RC5-1/250 1SBN050100R1002 2/14
AX12-30-01-80 1SBL911074R8001 2/3 AX115-30-11-81 1SFL981074R8111 2/7 RC5-1/440 1SBN050100R1003 2/14
AX12-30-10-86 1SBL911074R8610 2/3 AX115-30-11-88 1SFL981074R8811 2/7 RC5-2/50 1SBN050200R1000 2/14
AX12-30-01-86 1SBL911074R8601 2/3 AX115-30-11-84 1SFL981074R8411 2/7 RC5-2/133 1SBN050200R1001 2/14
AX18-30-10-81 1SBL921074R8110 2/3 AX115-30-11-80 1SFL981074R8011 2/7 RC5-2/250 1SBN050200R1002 2/14
6 AX18-30-01-81 1SBL921074R8101 2/3 AX115-30-11-86 1SFL981074R8611 2/7 RC5-2/440 1SBN050200R1003 2/14
AX18-30-10-88 1SBL921074R8810 2/3 AX150-30-11-81 1SFL991074R8111 2/7 RC5-3/440 1SFN050300R1003 2/14
AX18-30-01-88 1SBL921074R8801 2/3 AX150-30-11-88 1SFL991074R8811 2/7 RC5-3/440 1SFN050300R1003 2/15
AX18-30-10-84 1SBL921074R8410 2/3 AX150-30-11-84 1SFL991074R8411 2/7 WB75-A FPTN372726R1001 2/14
AX18-30-01-84 1SBL921074R8401 2/3 AX150-30-11-80 1SFL991074R8011 2/7 WB75-A FPTN372726R1006 2/14
AX18-30-10-80 1SBL921074R8010 2/3 AX150-30-11-86 1SFL991074R8611 2/7 LT185-AC 1SFN124701R1000 2/15
AX18-30-01-80 1SBL921074R8001 2/3 AX185-30-11-81 1SFL491074R8111 2/8 LT185-AL 1SFN124703R1000 2/15
AX18-30-10-86 1SBL921074R8610 2/3 AX185-30-11-88 1SFL491074R8811 2/8 LT370-30C 1SFN125401R1000 2/15
AX18-30-01-86 1SBL921074R8601 2/3 AX185-30-11-84 1SFL491074R8411 2/8
LT370-30L 1SFN125403R1000 2/15
AX25-30-10-81 1SBL931074R8110 2/3 AX185-30-11-80 1SFL491074R8011 2/8
LX185 1SFN074707R1000 2/15
AX25-30-01-81 1SBL931074R8101 2/3 AX185-30-11-86 1SFL491074R8611 2/8
LX300 1SFN075107R1000 2/15
AX25-30-10-88 1SBL931074R8810 2/3 AX205-30-11-81 1SFL501074R8111 2/8
LW185 1SFN074710R1000 2/15
AX25-30-01-88 1SBL931074R8801 2/3 AX205-30-11-88 1SFL501074R8811 2/8
LW300 1SFN075110R1000 2/15
AX25-30-10-84 1SBL931074R8410 2/3 AX205-30-11-84 1SFL501074R8411 2/8
NX22E-81 1SBH901074R8122 2/34
AX25-30-01-84 1SBL931074R8401 2/3 AX205-30-11-80 1SFL501074R8011 2/8
NX22E-88 1SBH901074R8822 2/34
AX25-30-10-80 1SBL931074R8010 2/3 AX205-30-11-86 1SFL501074R8611 2/8
NX22E-84 1SBH901074R8422 2/34
AX25-30-01-80 1SBL931074R8001 2/3 AX260-30-11-81 1SFL547074R8111 2/9
NX22E-80 1SBH901074R8022 2/34
AX25-30-10-86 1SBL931074R8610 2/3 AX260-30-11-88 1SFL547074R8811 2/9
NX22E-86 1SBH901074R8622 2/34
AX25-30-01-86 1SBL931074R8601 2/3 AX260-30-11-84 1SFL547074R8411 2/9
NX31E-81 1SBH901074R8131 2/34
AX32-30-10-81 1SBL281074R8110 2/4 AX260-30-11-80 1SFL547074R8011 2/9
NX31E-88 1SBH901074R8831 2/34
AX32-30-01-81 1SBL281074R8101 2/4 AX260-30-11-86 1SFL547074R8611 2/9
NX31E-84 1SBH901074R8431 2/34
AX32-30-10-88 1SBL281074R8810 2/4 AX300-30-11-81 1SFL587074R8111 2/9
NX31E-80 1SBH901074R8031 2/34
AX32-30-01-88 1SBL281074R8801 2/4 AX300-30-11-88 1SFL587074R8811 2/9
NX31E-86 1SBH901074R8631 2/34
AX32-30-10-84 1SBL281074R8410 2/4 AX300-30-11-84 1SFL587074R8411 2/9
NX40E-81 1SBH901074R8140 2/34
AX32-30-01-84 1SBL281074R8401 2/4 AX300-30-11-80 1SFL587074R8011 2/9
AX32-30-10-80 1SBL281074R8010 2/4 AX300-30-11-86 1SFL587074R8611 2/9
NX40E-88 1SBH901074R8840 2/34
AX32-30-01-80 1SBL281074R8001 2/4 AX370-30-11-81 1SFL607074R8111 2/9
NX40E-84 1SBH901074R8440 2/34
AX32-30-10-86 1SBL281074R8610 2/4 AX370-30-11-88 1SFL607074R8811 2/9 NX40E-80 1SBH901074R8040 2/34
AX32-30-01-86 1SBL281074R8601 2/4 AX370-30-11-84 1SFL607074R8411 2/9 NX40E-86 1SBH901074R8640 2/34
AX40-30-10-81 1SBL321074R8110 2/4 AX370-30-11-80 1SFL607074R8011 2/9 TE5S-24 1SBN020010R1001 2/45
AX40-30-01-81 1SBL321074R8101 2/4 AX370-30-11-86 1SFL607074R8611 2/9 TE5S-120 1SBN020010R1002 2/45
AX40-30-10-88 1SBL321074R8810 2/4 CA5X-10 1SBN019010R1010 2/13 TE5S-240 1SBN020010R1003 2/45
AX40-30-01-88 1SBL321074R8801 2/4 CA5X-01 1SBN019010R1001 2/13 TE5S-440 1SBN020010R1004 2/45
AX40-30-10-84 1SBL321074R8410 2/4 CA5X-22E 1SBN019040R1022 2/13 CT-ERS.21 1SVR630100R0300 2/45
AX40-30-01-84 1SBL321074R8401 2/4 CA5X-31E 1SBN019040R1031 2/13 WB75-A- 24V FPTN372726R1001 2/49
AX40-30-10-80 1SBL321074R8010 2/4 CA5X-40E 1SBN019040R1040 2/13 WB75-A- 42V FPTN372726R1002 2/49
AX40-30-01-80 1SBL321074R8001 2/4 CA5X-04E 1SBN019040R1004 2/13 WB75-A- 48V FPTN372726R1003 2/49
AX40-30-10-86 1SBL321074R8610 2/4 CA5X-22M 1SBN019040R1122 2/13 WB75-A- 110V FPTN372726R1004 2/49
AX40-30-01-86 1SBL321074R8601 2/4 CA5X-31M 1SBN019040R1131 2/13 WB75-A- 220V FPTN372726R1005 2/49
AX50-30-00-81 1SBL351074R8100 2/5 CA5X-13M 1SBN019040R1113 2/13 WB75-A- 230V FPTN372726R1006 2/49
AX50-30-00-88 1SBL351074R8800 2/5 CA5X-04M 1SBN019040R1104 2/13 WB75-A- 380V FPTN372726R1007 2/49
AX50-30-00-84 1SBL351074R8400 2/5 CA5X-22U 1SBN019040R1322 2/13 WB75-A- 415V FPTN372726R1008 2/49
AX50-30-00-80 1SBL351074R8000 2/5 CA5X-31U 1SBN019040R1331 2/13 MS116-0.16 1SAM250000R1001 3/4
AX50-30-00-86 1SBL351074R8600 2/5 CA5X-40U 1SBN019040R1340 2/13 MS116-0.25 1SAM250000R1002 3/4
AX65-30-00-81 1SBL371074R8100 2/5 CA5X-04U 1SBN019040R1304 2/13 MS116-0.4 1SAM250000R1003 3/4
AX65-30-00-88 1SBL371074R8800 2/5 CA5X-22N 1SBN019040R1222 2/13 MS116-0.63 1SAM250000R1004 3/4
AX65-30-00-84 1SBL371074R8400 2/5 CA5X-31N 1SBN019040R1231 2/13 MS116-1.0 1SAM250000R1005 3/4
AX65-30-00-80 1SBL371074R8000 2/5 CA5X-13N 1SBN019040R1213 2/13 MS116-1.6 1SAM250000R1006 3/4
AX65-30-00-86 1SBL371074R8600 2/5 CA5X-04N 1SBN019040R1204 2/13 MS116-2.5 1SAM250000R1007 3/4
AX80-30-00-81 1SBL411074R8100 2/5 CA5X-40N 1SBN019040R1240 2/13 MS116-4.0 1SAM250000R1008 3/4
AX80-30-00-88 1SBL411074R8800 2/5 CAL5X-11 1SBN019020R1011 2/13 MS116-6.3 1SAM250000R1009 3/4
1SYN829571C201
6/1 | ABB
Index
Order code classification
Type Order Code Page Type Order Code Page Type Order Code Page
MS116-0.16+ HKF1-11 1SAM250005R1001 3/4 UA1-415 1SAM201904R1007 3/15 TA42DU-42M 1SAZ311201R2003 4/3
MS116-0.25+ HKF1-11 1SAM250005R1002 3/4 MS450-40 1SAM450000R1005 3/17 TA75DU-25M 1SAZ321201R2001 4/3
MS116-0.4+ HKF1-11 1SAM250005R1003 3/4 MS450-45 1SAM450000R1006 3/17 TA75DU-32M 1SAZ321201R2002 4/3
MS116-0.63+ HKF1-11 1SAM250005R1004 3/4 MS450-50 1SAM450000R1007 3/17 TA75DU-42M 1SAZ321201R2003 4/3
MS116-1.0+ HKF1-11 1SAM250005R1005 3/4 MS495-63 1SAM550000R1007 3/17 TA75DU-52M 1SAZ321201R2004 4/3
MS116-1.6+ HKF1-11 1SAM250005R1006 3/4 MS495-75 1SAM550000R1008 3/17 TA75DU-63M 1SAZ321201R2005 4/3
MS116-2.5+ HKF1-11 1SAM250005R1007 3/4 MS495-90 1SAM550000R1009 3/17 TA75DU-80M 1SAZ321201R2006 4/3
MS116-4.0+ HKF1-11 1SAM250005R1008 3/4 MS495-100 1SAM550000R1010 3/17 DX25 1SAZ201307R0002 4/6
MS116-6.3+ HKF1-11 1SAM250005R1009 3/4 MS497-32 1SAM580000R1004 3/17 DB25/25A 1SAZ201108R0001 4/6
MS116-10+ HKF1-11 1SAM250005R1010 3/4 MS497-40 1SAM580000R1005 3/17 DB25/32A 1SAZ201108R0002 4/6
MS116-12+ HKF1-11 1SAM250005R1011 3/4 MS497-50 1SAM580000R1006 3/17 DB80 1SAZ301110R0001 4/6
MS116-16+ HKF1-11 1SAM250005R1012 3/4 MS497-63 1SAM580000R1007 3/17 DR25-A-24 1SAZ201504R0001 4/6
MS116-20+ HKF1-11 1SAM250005R1013 3/4 MS497-75 1SAM580000R1008 3/17 DR25-A-48 1SAZ201504R0002 4/6
MS116-25+ HKF1-11 1SAM250005R1014 3/4 MS497-90 1SAM580000R1009 3/17 DR25-A-110 1SAZ201504R0003 4/6
MS116-32+ HKF1-11 1SAM250005R1015 3/4 MS497-100 1SAM580000R1010 3/17 DR25-A-220/380 1SAZ201504R0005 4/6
MS132-0.63 1SAM350000R1004 3/7 MO450-40 1SAM460000R1005 3/20 DR25-A-500 1SAZ201504R0006 4/6
MS132-1.0 1SAM350000R1005 3/7 MO450-45 1SAM460000R1006 3/20 KPR-101L 1SFA616162R1014 4/6
MS132-1.6 1SAM350000R1006 3/7 MO450-50 1SAM460000R1007 3/20 TA80DU-42 1SAZ331201R1003 4/7
MS132-2.5 1SAM350000R1007 3/7 MO495-63 1SAM560000R1007 3/20 TA80DU-52 1SAZ331201R1004 4/7
MS132-4.0 1SAM350000R1008 3/7 MO495-75 1SAM560000R1008 3/20 TA80DU-63 1SAZ331201R1005 4/7
MS132-6.3 1SAM350000R1009 3/7 MO495-90 1SAM560000R1009 3/20 TA80DU-80 1SAZ331201R1006 4/7
MS132-10 1SAM350000R1010 3/7 MO495-100 1SAM560000R1010 3/20 TA110DU-90 1SAZ411201R1001 4/7 6
MS132-12 1SAM350000R1011 3/7 MO496-32 1SAM590000R1004 3/20 TA110DU-110 1SAZ411201R1002 4/7
MS132-16 1SAM350000R1012 3/7 MO496-40 1SAM590000R1005 3/20 TA200DU-90 1SAZ421201R1001 4/7
MS132-20 1SAM350000R1013 3/7 MO496-50 1SAM590000R1006 3/20 TA200DU-110 1SAZ421201R1002 4/7
MS132-25 1SAM350000R1014 3/7 MO496-63 1SAM590000R1007 3/20 TA200DU-135 1SAZ421201R1003 4/7
MS132-32 1SAM350000R1015 3/7 MO496-75 1SAM590000R1008 3/20 TA200DU-150 1SAZ421201R1004 4/7
MS132-0.16+ HKF1-11 1SAM350005R1001 3/7 MO496-90 1SAM590000R1009 3/20 TA200DU-175 1SAZ421201R1005 4/7
MS132-0.25+ HKF1-11 1SAM350005R1002 3/7 MO496-100 1SAM590000R1010 3/20 TA200DU-200 1SAZ421201R1006 4/7
MS132-0.4+ HKF1-11 1SAM350005R1003 3/7 HK4-11 1SAM401901R1001 3/24 LT200/A 1SAZ401901R1001 4/7
MS132-0.63+ HKF1-11 1SAM350005R1004 3/7 HK4-W 1SAM401901R1002 3/24 DB200 1SAZ401110R0001 4/7
MS132-1.0+ HKF1-11 1SAM350005R1005 3/7 HKS4-11 1SAM401902R1001 3/24 KPR-101L 1SFA616162R1014 4/7
MS132-1.6+ HKF1-11 1SAM350005R1006 3/7 HKS4-20 1SAM401902R1002 3/24 E16DU-0.32 1SAX111001R1101 4/12
MS132-2.5+ HKF1-11 1SAM350005R1007 3/7 HKS4-02 1SAM401902R1003 3/24 E16DU-1.0 1SAX111001R1102 4/12
MS132-4.0+ HKF1-11 1SAM350005R1008 3/7 SK4-11 1SAM401904R1001 3/24 E16DU-2.7 1SAX111001R1103 4/12
MS132-6.3+ HKF1-11 1SAM350005R1009 3/7 AA4-24 1SAM401907R1001 3/24 E16DU-6.3 1SAX111001R1104 4/12
MS132-10+ HKF1-11 1SAM350005R1010 3/7 AA4-110 1SAM401907R1002 3/24 E16DU-18.9 1SAX111001R1105 4/12
MS132-12+ HKF1-11 1SAM350005R1011 3/7 AA4-230 1SAM401907R1003 3/24 E45DU-30 1SAX211001R1101 4/12
MS132-16+ HKF1-11 1SAM350005R1012 3/7 AA4-400 1SAM401907R1004 3/24 E45DU-45 1SAX211001R1102 4/12
MS132-20+ HKF1-11 1SAM350005R1013 3/7 UA4-24 1SAM401905R1004 3/24 E80DU-80 1SAX311001R1101 4/12
MS132-25+ HKF1-11 1SAM350005R1014 3/7 UA4-100 1SAM401905R1001 3/24 E140DU-140 1SAX321001R1101 4/12
MS132-32+ HKF1-11 1SAM350005R1015 3/7 UA4-230 1SAM401905R1002 3/24 DB16E 1SAX101110R0001 4/15
MO132-0.63 1SAM360000R1004 3/10 UA4-400 1SAM401905R1003 3/24 DB45E 1SAX201110R0001 4/15
MO132-1.0 1SAM360000R1005 3/10 UA4-HK-230 1SAM401906R1001 3/24 DB80E 1SAX301110R0001 4/15
MO132-1.6 1SAM360000R1006 3/10 UA4-HK-400 1SAM401906R1002 3/24 DB140E 1SAX301110R0002 4/15
MO132-2.5 1SAM360000R1007 3/10 OXS6X85 1SCA101647R1001 3/26 EF205-210 1SAX531001R1101 4/16
MO132-4.0 1SAM360000R1008 3/10 OXS6X105 1SCA108043R1001 3/26 EF370-380 1SAX611001R1101 4/16
MO132-6.3 1SAM360000R1009 3/10 OXS6X130 1SCA101655R1001 3/26
MO132-10 1SAM360000R1010 3/10 OXS6X180 1SCA101659R1001 3/26
MO132-12 1SAM360000R1011 3/10 MSHD-LB (1) 1SAM201920R1001 3/26
MO132-16 1SAM360000R1012 3/10 MSHD-LY (1) 1SAM201920R1002 3/26
MO132-20 1SAM360000R1013 3/10 MSHD-LTB (2) 1SAM201920R1011 3/26
MO132-25 1SAM360000R1014 3/10 MSHD-LTY (2) 1SAM201920R1012 3/26
MO132-32 1SAM360000R1015 3/10 MSMN (3) 1SAM101923R0002 3/26
HKF1-11 1SAM201901R1001 3/14 MSMNO (4) 1SAM101923R0012 3/26
HKF1-20 1SAM201901R1002 3/14 MSH-AR 1SAM201920R1000 3/26
HK1-11 1SAM201902R1001 3/14 MSAH1 1SAM201909R1021 3/26
HK1-20 1SAM201902R1002 3/14 TA25DU-0.16M 1SAZ211201R2005 4/3
HK1-02 1SAM201902R1003 3/14 TA25DU-0.25M 1SAZ211201R2009 4/3
HK1-20L 1SAM201902R1004 3/14 TA25DU-0.4M 1SAZ211201R2013 4/3
SK1-11 1SAM201903R1001 3/14 TA25DU-0.63M 1SAZ211201R2017 4/3
SK1-20 1SAM201903R1002 3/14 TA25DU-1.0M 1SAZ211201R2021 4/3
SK1-02 1SAM201903R1003 3/14 TA25DU-1.4M 1SAZ211201R2023 4/3
CK1-11 1SAM301901R1001 3/14 TA25DU-1.8M 1SAZ211201R2025 4/3
CK1-20 1SAM301901R1002 3/14 TA25DU-2.4M 1SAZ211201R2028 4/3
CK1-02 1SAM301901R1003 3/14 TA25DU-3.1M 1SAZ211201R2031 4/3
AA1-24 1SAM201910R1001 3/15 TA25DU-4.0M 1SAZ211201R2033 4/3
AA1-110 1SAM201910R1002 3/15 TA25DU-5.0M 1SAZ211201R2035 4/3
AA1-230 1SAM201910R1003 3/15 TA25DU-6.5M 1SAZ211201R2038 4/3
AA1-400 1SAM201910R1004 3/15 TA25DU-8.5M 1SAZ211201R2040 4/3
UA1-24 1SAM201904R1001 3/15 TA25DU-11M 1SAZ211201R2043 4/3
1SYN829571C201
ABB | 6/2
ABB AB
in Fr
1SBC10
We reserve all rights in this document and in the
Control Products
ABB STOTZ-KONTAKT GmbH
1SBC100173C0201 - Printed
subject matter and illustrations contained therein.
Contactus
Contact us
Low Voltage Products Any reproduction, disclosure to third parties or
Eppelheimer Straße 82 utilization of its contents – in whole or in parts – is
SE-721 61
D-69123 Västerås // Sweden
Heidelberg Germany forbidden without prior written consent of ABB.
You
ABBcan
ABfind the address of your local sales organisation
on North
the ABB
Control home page
Products West Chennai:
PDF)
Tel: +91 44 2829 1550/1551
We reserve the right to make technical changes or
reserved
Low
on theVoltage
ABB129
+91 Products
home227 9627 Division
page
www.abb.com/connecttocontrol
Tel: Fax: +91 22 6631 4203 Fax:the
modify +91 44 2829
contents 1554
of this document without prior
rights(03.2013
3, Tel:
rue Jean Perrin
+91 129 504 9000 notice.
ABB does not accept any responsibility whatsoever
F-69687 Chassieu
Fax: +91 129 227 cedex
9692/ France Pune: forCoimbatore:
potential errors or possible lack of information in
France
Fax: +91 129 227 5019 Tel: + 91 20 6624 3838 thisTel:
document.
+91 422 2300 3415
ABB.in All
Fax: + 91 20 6624 3817 WeFax: +91all422
reserve rights230 3415
in this document and in the
ABB STOTZ-KONTAKT GmbH
- Printed
www.abb.com/lowvoltage
Chandigarh: subject matter and illustrations contained therein.
Works:
Any reproduction, disclosure to third parties or
Eppelheimer Straße
432182
- copyright 2013
Tel: +91 172 800
www.abb.com/connecttocontrol Ahmedabad: utilization of its contents – in whole or in parts – is
D-69123 Heidelberg
Fax: +91 172 2601/ 618
Germany Tel: + 91 79 6609 0112 forbidden without prior written consent of ABB.
Nelamangala
1SBC100173C0201
Fax: +91 79 6609 0105 Survey No:
Copyright© 201388/3,
ABB -88/4,
All rights reserved
Dehradun Basavanhalli, Kasaba Hobli,
ABB Nelamangala Taluk,
Tel:AB
+91 135 2762 731
1SYN829571C201
Control Products Bangalore - 562123, Karnataka, India
Fax: +91 135 2760 655
www.abb.com/lowvoltage Bhopal: Tel: +91 80 2294 8995
Low Voltage Products Tel : +91 755 4087 601-10 Fax: +91 80 2294 9999
SE-721 61 Västerås / Sweden
Jaipur: Fax: + 91 755 4087 611
Tel: +91 141 274 4024 Peenya
Fax: +91 141 274 4027 Nagpur: Plot no.5 & 6, II Phase,
You can find the address of your local sales organisation Peenya Industrial Area 560058,
Tel : +91 712 646 1145/46/45/49
on Lucknow:
the ABB home page Bangalore, Karnataka, INDIA
Fax: + 91 712 229 0283 Phone: +91 80 22949354/9585
Tel: +91 522 220 9436 Telefax: +91 80 22949389
Fax: +91 522 220 9478 Vododara:
Tel : +91 265 264 2141
Ludhiana Fax: + 91 265 264 0716 ABB India Helpline:
Tel: +91 161 465 6830/31
www.abb.com/connecttocontrol
Fax: +91 161 465 6830 South Technical Telephone support for customers
and channel partners.
East Khanija Bhavan, 5th Floor, West Wing, Toll Free : (BSNL) +91 1800 420 07 07
No: 49, Race Course Rd, Bangalore -
email : lp.contactcenter@in.abb.com
ABB ltd, Omega Building, 560001.
17th Floor, Bengal Intelligent Park, Block
www.abb.com/lowvoltage Tel: + 91 80 2294 9250
EP & GR Salt Lake City, Kolkota - 700091. Fax:+91 80 2294 6702/03
www.abb.com/lowvoltage
TeI: + 91 33 6621 3000 -11
Fax: +91 33 6621 3187 Hyderabad:
Tel : + 91 40 2790 6736/29
Products available at:
Bhubaneshwar: Fax: + 91 40 2790 6648
Tel : +91 674 6616 302/311
Fax: + 91 674 6616 307 Kochi:
Te I: +91 484 233 0342
Jamshedpur: Fax: +91 484 233 0343
Tel : +91 657 6619 200
Fax: +91 657 6619 200 Vishakapatnam:
Tel: +91 891 2538 188
Raipur Fax: +91 891 2795 837
Tel: +91 771 4213 204
Fax: +91 771 4213 222