0% found this document useful (0 votes)
16 views2 pages

Sureseal 1208 Uwe With 815

KANSAI SURESEAL 1208 UWE is a solvent-free, two-pack epoxy mastic designed for corrosion and abrasion protection in extreme environments, capable of curing underwater. It is suitable for various applications including offshore marine structures, wastewater tanks, and rehabilitation of corroded steel and concrete. The product offers excellent adhesion, chemical resistance, and is ideal for maintenance coatings on cold pipes.

Uploaded by

sgjsevenp
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
16 views2 pages

Sureseal 1208 Uwe With 815

KANSAI SURESEAL 1208 UWE is a solvent-free, two-pack epoxy mastic designed for corrosion and abrasion protection in extreme environments, capable of curing underwater. It is suitable for various applications including offshore marine structures, wastewater tanks, and rehabilitation of corroded steel and concrete. The product offers excellent adhesion, chemical resistance, and is ideal for maintenance coatings on cold pipes.

Uploaded by

sgjsevenp
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 2

KANSAI SURESEAL 1208 UWE – UNDER WATER AND WET SURFACE EPOXY MASTIC

DESCRIPTION
KANSAI SURESEAL 1208 UWE is a high performance solvent free, two-pack epoxy mastic designed to provide corrosion resistance and abrasion protection
in extreme service applications. This specially designed epoxy Resin for Fiber systems is capable of application and curing underwater and form a tough
protective barrier and Retrofitting Marine structure member . It provides outstanding adhesion on wet blasted surfaces.

RECOMMENDED USES
KANSAI SURESEAL 1208 UWE is designed to provide corrosion protection for metal and concrete structures in offshore marine and petrochemical services,
sheet piles, underground and submarine pipes, waste water tanks, jetty piles, underground tanks and other structural steel that requires protection against
corrosion in aggressive environment. It is most suitable for rehabilitation of corroded steel and concrete structures in tidal zone and below water line
where conventional protective coatings are not applicable. It is an ideal maintenance coating or Lining systems for cold pipes with condensation.

ADVANTAGES
- Tough and impermeable layer with excellent resistance against salt and water.
– Solvent free product

- Good resistance against wide range of chemicals.


-water curing - capable of application and curing under water.
- Excellent adhesion to dry and wet surfaces.

CHEMICAL RESISTANCE GUIDE


Exposure Immersion Splash & Spillage Fumes
Acids Very Good Excellent Excellent
Alkali Very Good Excellent Excellent
Solvents Very Good Excellent Excellent
Salt water Excellent Excellent Excellent
Water Excellent Excellent Excellent

PHYSICAL DATA
Finish : Gloss / Matte (*)
Volume Solids : 100 %
No. of Components : Two
Mixing Ratio : 4 Part A : 1 Part B by weight
Recommended DFT : 150 microns per coat as primer & 1000 microns w/ fiber reinforcing purpose
Theoretical Coverage : 3.83 m2/kg @ 150 microns DFT.
No. of coats : 2 or 3 coats.
Drying Time – Touch dry : 4 hours
Topcoat : 12 hours
Full cure : 7 days
Pot life : 45 minutes at 300C (varies with temperature)
Packing Size : Part A – 4 kg , Part B – 1 kg
(*) Surface finish will be matte when coating is underwater or surface covered by water during curing.

APPLICATION INSTRUCTIONS
SURFACE PREPARATION: Remove oil and grease from surface to be painted with suitable degreaser prior to painting for surfaces above water.
Steel: For maximum protection, wet abrasive blasting to remove surface contaminants and create surface profile about 50 to 75 microns. Ultra high
pressure hydro jetting is acceptable for maintenance of previously painted surfaces.
Dry abrasive blast cleaning to minimum standard Sa 1 & for repair of small area minimum standard St 3.
Concrete: Wet blasting or high pressure water jet blasting is recommended to remove surface contaminants before application of coatings.
MIXING: Mix Component-A thoroughly then mix in Component-B and continue to mix till homogeneous. Do not mix more materials than the quantity to
be consumed within the pot life.
THINNING: Thinning is not allowed for underwater applications. For applications above water to overcome issue related to workability of spray equipment,
not more than 10% by weight of Thinner #72 is allowed.
APPLICATION: KANSAI SURESEAL can be applied by brush,roller or spray above water and for underwater applications,brush or roller is recommended.
CLEANING: Clean all application tools with KANSAI PLC Thinner # 72 immediately after use.
TECHNICAL DATA SHEET

E-LT815

Areal
Layer Tolerance Material Roving Diameter Resin
Weight
Construction [+/-%] Type Tex [µm] Compatibility
[g/m2]

upper side
0 ͦ 404 5 E-glass 1103 17 UP,VE,EP
90 ͦ 404 5 E-glass 600 17 UP,VE,EP
lower side

Stitching 18±1 g/m2 Material PES 166dtex

Stitching Pattern : Long Chain Tricot Stitching Gauge : 7


Total Areal Weight : 815 g/m2 Total Tolerance : ±5%
Roll Width : Nominal ± 10mm Roll Length : Nominal ± 1m