ABB High Voltage Induction Motors

Technical catalogue
High Voltage Induction Motors
From 110 to 2800 kW

Contents Page

1
Standard motors 5
1

2
2 Engineered motors 45

3
3 Motors with VSD 125

ABB reserves the right to change the


design, technical specification and
dimensions without prior notice.

ABB/ BU Machines / HV Induction motors IEC catalogue EN 05-2006 3


General Information
This catalogue includes three sections: standard, motors. All the engineered motors are configured and
engineered and motors with VSD. The availability of optimized for each order and application.
standard motors is shown in the Section 1. Standard
motors of up to 530 kW are available with the electrical Section 3 describes ABB's engineered motors for low
and mechanical design characteristics as shown in this voltage variable speed drives range of up to 2240 kW.
catalogue. This section includes preliminary standard technical
data and drawings with low voltage main terminal box.
Section 2 presents ABB's high voltage engineered The basic mechanical construction is the same as
induction motor range of up to 2800 kW. Engineered described in Section 2. As with the engineered motors
motors are made according to customers' all the motors with VSD are configured and optimized
specifications. This section includes preliminary for each order and application.
standard technical data and drawings of engineered

4 ABB/ BU Machines / HV Induction motors IEC catalogue EN 05-2006


High Voltage Process Performance
Cast Iron Motors
Totally enclosed squirrel cage three phase high
voltage motors,
Sizes 315 - 400, 110 to 530 kW

www.abb.com/motors&drives
> Motors
>> High Voltage Motors
>>> Process Performance
Cast Iron Motors, 315-400

Mechanical design ...............................6


Ordering information ..........................17
Technical data....................................18
Variant codes. ....................................38
Dimension drawings ..........................39
Accessories .......................................41
Construction ......................................42
Cast iron motors in brief ....................43

ABB/ BU Machines / HV Induction motors IEC catalogue / Standard motors EN 05-2006 5


Mechanical design
The standard motors in this Section are offered with need an engineered cast iron motor, please see the
limited optional features and accessories. In case you Section 2.

Stator frame
The motor frames feature integrally cast feet to provide can be supplied for foot mounting (horizontal) or
a very rigid mounting and minimal vibration; the feet flange mounting (vertical). The terminal box is made of
and bearing housing are made of cast iron. Motors structural steel.

Drain holes
All high voltage motors are fitted with drain holes For applications with a vertical mounting, the upper
and closable plugs. The drain hole plugs are open on plug must be hammered home completely. In very dusty
delivery and users must ensure that the drain holes environments, both plugs should be hammered home.

1 face downward when mounting the motors.

Closed

Open

Motor sizes 315-400


As standard with drain holes and closable plugs.

6 ABB/ BU Machines / HV Induction motors IEC catalogue / Standard motors EN 05-2006


Terminal boxes
The high voltage terminal box is shown below. The main
technical data are listed below.
Technical data: Materials:
Voltage (max.) 6.6 kV Box welded structural steel
Current (max.) 400 A (thickness min. 3 mm)
No of cables (max.) 1 per phase Cable gland plate steel
Cross section of cables (max.) 300 mm2/cable Connection screws Bronze Bz
Cable gland blind gland (1 pce) Isolators epoxy casting resin or
Clearance (min.) 60 mm polyurethane resin
Creepage (min.) 90 mm Grounding pad stainless steel
Gross volume 47.3 dm3
Usable volume 42.1 dm3
Other features:
Connection screws M16 (3 pcs)
Connection nuts tightening torque 40 Nm - rigid welded construction
Ground connections M12 (both in- and - ample size for making connections of supply cables
outside) - box turnable to allow cable entry from left or right side
Weight 33 kg - box turnable in steps of 90°
- either 3-phase or 1-phase cables can be connected
Protection
Standard
Dynamic short circuit current
IP 66
DIN 42962 TEIL 1, A2
30 kA rms x 0.25 s/
- pressure relief plate in the bottom of the box in case
of an arching short circuit
1
75 kA peak

High voltage terminal box.

ABB/ BU Machines / HV Induction motors IEC catalogue / Standard motors EN 05-2006 7


The high voltage star point terminal box is shown below
(option, variant code 750). The main technical data are
listed below.

Technical data: Materials:


Voltage (max.) 6.6 kV Box welded structural steel
Current (max.) 400 A (thickness min. 3 mm)
Cable gland blind gland (1 pce) Cable gland plate steel
Creepage (min.) 90 mm Connection screws Bronze Bz
Gross volume 47.3 dm3 Connection bar Copper Cu
Usable volume 42.1 dm3 Isolators epoxy casting resin or
Connection screws M16 (3 pcs) polyurethane resin
Connection nuts tightening torque 40 Nm Grounding pad stainless steel
Ground connections M12 (both in- and
outside) Other features:
Weight 33 kg - rigid welded construction
Protection IP 66 - box turnable to left or right side
- box turnable in steps of 90°
- pressure relief plate in the bottom of the box in case

1 of an arching short circuit

High voltage star point terminal box.

8 ABB/ BU Machines / HV Induction motors IEC catalogue / Standard motors EN 05-2006


Star point terminal box (optional)

1
Dimensions for terminal box inlet, blind flange

ABB/ BU Machines / HV Induction motors IEC catalogue / Standard motors EN 05-2006 9


Auxiliary boxes
Auxiliary box is used for control equipment and heating
elements.

- one box as default Other features:


- stator Pt-100 - equipped with assembly rail ARH 22
- bearing Pt-100 (optional, variant code 107) (DIN-35, 35x203 mm)
- heating element (optional, variant code 450/451) - main dimensions 125x222x81
- separate auxiliary box for heating element (optional, - degree of protection IP 66 (IEC 529)
variant code 447) - gasket material polyurethane
- temperature resistance -50 - +140 °C (material),
Specification: +80 °C (continuous use)
- max. terminal blocks: 34 pcs 2.5 mm2
Material designation Al-Si10Mg (pressure die cast)
28 pcs 4.0 mm2
Material standard EN 573-3
- weight 1.6 kg
Surface treatment RAL 7001 (grey)

10 ABB/ BU Machines / HV Induction motors IEC catalogue / Standard motors EN 05-2006


Bearings
Single-row deep groove ball bearings, as listed in the Higher radial forces can be handled if the bearings at
table below, are normally fitted to the motors. the D-end is replaced with a roller bearing (NU-). Roller
bearings are suitable for belt drive applications.

Basic version with deep groove ball bearings Version with roller bearings, variant code 037

Motor Number Deep groove ball bearings Motor Number Roller bearings, variant code 037
size of poles D-end N-end size of poles D-end

315 2 6316M/C3 6316M/C3 315 4-6 NU 319/C3


4-6 6319/C3 6316/C3 355 4-6 NU 322/C3
355 2 6316M/C3 6316M/C3 400 4-12 NU 324/C3
4-6 6322/C3 6316/C3
400 2 6317M/C3 6317M/C3
4-12 6324/C3 6319/C3

1
Axially-locked bearings
All motors are equipped with an axially-locked bearing The N-end bearing is axially free and can take the
at the D-end as standard. thermal expansion. NB: NU-bearing is axially locked at
N-end.
The bearing's outer ring is tightly locked between
bearing's covers and the housing fit.

Transport locking
Motors with roller bearings are fitted with a transport Locking may be fitted in any other situations where
lock to prevent damage to the bearings during the transport conditions are considered as potentially
transport. All high voltage motors are fitted with a damaging.
warning sign when the transport lock is fitted to prevent
operational damage and alert operators.

ABB/ BU Machines / HV Induction motors IEC catalogue / Standard motors EN 05-2006 11


Bearing seals
All high voltage motors are equipped with labyrinth
sealed bearings.

Axially free (N-end)

Axially locked (D-end)

12 ABB/ BU Machines / HV Induction motors IEC catalogue / Standard motors EN 05-2006


Lubrication
On delivery, the motors are pre-lubricated with high- Motors with relubrication nipples
quality grease. The grease grade is stamped on the
Motors are lubricated while running and the bearing
lubrication plate fastened to the motor frame. See
system on all high voltage motors has been built so that
page 16 for an example of a lubrication plate.
a valve disc can be used for lubrication.
More information about lubrication and greases can
The grease outlet opening has closing valves at both
be found in ABB's High Voltage Process Performance
ends that should be opened before greasing and closed
Manual delivered with the motor.
1-2 hours after regreasing. Closing the valves ensures
that the construction is tight and prevents dust or dirt
getting inside the bearing.

Lubrication intervals
The lubrication interval is defined by following the The table below gives lubrication intervals for different
L1-principle. This means that 99% of ABB's motors speeds (according to the L1-principle). The values are
will achieve normal service intervals. Values for the valid for horizontal mounted motors (B3), using high-
lubrication intervals can also be calculated according
to the L10-principle, which are normally doubled
quality lithium grease.
For more information, see ABB's High Voltage Process
1
compared to L1-values. Values are available from ABB
Performance Motors Manual.
on request.

Frame 3000 1500 <1000 Frame 3000 1500 <1000


size Ambient °C r/min r/min r/min size Ambient °C r/min r/min r/min

Ball bearings, horizontal motor: lubrication intervals in duty hours Ball bearings, vertical motor: lubrication intervals in duty hours
315 25 2600 8800 8800 315 25 - 4400 4400
315 40 1500 4400 4400 315 40 - 2200 2200
355 25 2200 4400 8800 355 25 - 2200 4400
355 40 1300 2200 4400 355 40 - 1100 2200
400 25 2000 3300 6300 400 25 - 1600 3300
400 40 1100 2000 3300 400 40 - 1100 1600

Frame 3000 1500 <1000


size Ambient °C r/min r/min r/min

Roller bearings: lubrication intervals in duty hours


315 25 - 6000 8800
315 40 - 3000 5500
355 25 - 3000 8000
355 40 - 1600 4000
400 25 - 2500 7000
400 40 - 1300 3600

NB: The motors require special grease for roller bearings.

ABB/ BU Machines / HV Induction motors IEC catalogue / Standard motors EN 05-2006 13


Pulley diameter
The minimum permissible pulley diameter can be where:
calculated using FR, once the desired bearing life has D= diameter of pulley, mm
been determined, using the following formula: P= power requirement, kW
n = motor speed, r/min
D=
1.9 · 107 · K · P K= belt tension factor, dependent on belt type
n · FR and type of duty. A common value for
V-belts is 2.5.
FR = permissible radial force

Permissible shaft loadings


The tables on next page give the maximum permissible
radial force in Newtons, assuming zero axial force,
based on normal conditions at 50 Hz and calculated
bearing lives L10h for 40,000 hours.
Motors are foot-mounted IM B3 version with force

1 directed sideways. In some cases the strength of the


shaft affects the permissible forces.
Permissible loads of simultaneous radial and axial forces
can be supplied on request.

If the radial force is applied between points X0 and Xmax,


the permissible force FR can be calculated from the
following formula:
X
FR = FX0 - (FX0 - FXmax)
E
E = length of shaft extension in basic version

14 ABB/ BU Machines / HV Induction motors IEC catalogue / Standard motors EN 05-2006


Permissible radial forces

Length of Ball bearings Roller bearings


shaft
Motor extension 40,000 hours 40,000 hours
size Poles E (mm) FX0 (N) FXmax(N) FX0 (N) FXmax(N)

315 2 140 4850 4300 - -


4 170 7900 6850 25900 9500
6 170 9050 7850 29200 9500
355 2 140 2350 2150 - -
4 210 9900 8600 35300 12000
6 210 11500 9950 39950 12000
400 2 170 550 500 - -
4 210 8850 7650 40250 15000
6-12 210 10250 8900 44800 15000

Permissible axial forces


The following tables give the permissible axial forces Given axial forces FAD, assumes D-bearing locked by
in Newton, assuming zero radial force. The values are
based on normal conditions at 50 Hz with standard
means of locking ring.
1
bearings and calculated bearing lives L10h 40,000 hours.

Mounting arrangement IM B3 Mounting arrangement IM V1


FAZ

!
FAD # % FAZ "
FAD

40,000 hours 40,000 hours


2-pole 4-pole 6-12-pole 2-pole 4-pole 6-12-pole
Motor FAD FAZ FAD FAZ FAD FAZ Motor FAD FAZ FAD FAZ FAD FAZ
size N N N N N N size N N N N N N

315 2050 4050 4150 6150 5050 7050 315 - - 7650 3750 9150 4350
355 850 4650 4350 8150 5650 9450 355 - - 10900 3850 12700 4600
400 200 5200 3100 9100 4050 10050 400 - - 11550 3550 15100 2600

ABB/ BU Machines / HV Induction motors IEC catalogue / Standard motors EN 05-2006 15


Vibration limits / Balancing
Motors are balanced according to ISO1940: 1998 The following table lists the vibration values that the
standard, balancing grade G2.5. machines fulfil in compliance with IEC 60034-14.

Poles Speed Design Bearing housing


rpm vibration

2 1800 < n 3600 Standard 2.3 mm/s rms


≥4 1800 Standard 2.3 mm/s rms

Rating plate
Rating plate Lubrication plate

Restamping output, voltage, ambient and altitude


M3BM motor catalogue ratings can be re-stamped Ambient temperature
as follows. Motor construction will not be changed
but a new rating plate and data sheet can be created Motor can be de-rated to higher ambient temperature.
with variant code 002. In all the below cases or their Maximum ambient temperature is 55 °C. The output
combinations, please contact ABB for correct motor has to be de-rated so that motor's absolute temperature
size and motor data. Bearing re-lubrication intervals as will not be higher than the catalogue data.
shown in this catalogue are valid also for re-stamped NB: Motors with CSA and GOST certificate cannot
motors. be re-stamped to higher than 40 °C ambient. Ambient
temperature is limited in the certificates.
Output
Output can be re-stamped downwards from the Altitude
catalogue data, however the minimum output available Motor can be de-rated to higher altitudes than standard
for hazardous area motors is 110 kW. 1000 meters above sea level. There are different
maximum altitude limits for different motors depending
Voltage on voltage level. The motor output has to be de-rated so
Voltage can be re-stamped downwards up to 10% that the absolute temperature of the motor will not be
from the motor nominal voltage in the catalogue. Motor higher than the catalogue data.
output has to be de-rated so that the motor absolute NB: M3GM (Ex) motors for higher than 1000 meters
temperature will not be higher compared to catalogue above sea level altitude can be offered only case by
data. case from the manufacturing unit.

16 ABB/ BU Machines / HV Induction motors IEC catalogue / Standard motors EN 05-2006


Ordering information
When placing an order, please state the following Motor type M3BM 315LKA
minimum data in the order, as in the example. Pole number 4
The product code of the motor is composed in Mounting arrangement (IM code) IM B3 (IM 1001)
Rated output 110 kW
accordance with the following example.
Product code 3GBM312810-AQA
Variant codes if needed

Motor size
A Motor type
A B C D, E, F, G B Motor size
C Product code
D Mounting arrangement code
M3BM 315LKA 3GBM 312 810 - A Q A 003 etc. E Voltage and frequency code
F Generation code
1 2 3 4 5 6 7 8 9 10 11 12 13 14
G Variant codes

Explanation of the product code:


Positions 1 to 4 Position 11

1
3GBM = Totally enclosed fan cooled squirrel cage motor with cast - (dash)
iron frame, high voltage
Position 12
Positions 5 and 6 Mounting arrangement
IEC-frame A = Horizontal
31 = 315 B = Vertical
35 = 355
40 = 400
Position 13
Position 7 Voltage and frequency code
Speed (Pole pairs) See table below
1 = 2 poles Position 14
2 = 4 poles Generation code
3 = 6 poles A, B, C...
4 = 8 poles
5 = 10 poles The product code must be, if needed, followed by variant codes.
6 = 12 poles

Position 8 to 10
Serial number

Code letters for supplementing the product code - single speed motors
Code letter for voltage and frequency

Q R S T
50 Hz 50 Hz 50 Hz 50 Hz
3000 V 3300 V 6600 V 6000 V

ABB/ BU Machines / HV Induction motors IEC catalogue / Standard motors EN 05-2006 17


HV Process performance cast iron motors
Technical data for totally enclosed squirrel
cage three phase motors
IP 55 – IC 411 – Insulation class F, temperature rise class B
Efficiency Power factor Current
Full 3/4 Full 3/4 IN IS I0
Output Motor type Product code Speed load load load load
kW r/min 100% 75% 100% 75% A IN A

3000 r/min = 2 poles 3000 V 50 Hz


132 M3BM 315 LKA 3GBM 311 810-•QA 2971 94.7 94.5 0.92 0.92 29 6.3 5
160 M3BM 315 LKB 3GBM 311 820-•QA 2971 94.9 94.8 0.92 0.92 35 6.5 6
200 M3BM 355 LKA 3GBM 351 810-•QA 2974 95.0 94.9 0.90 0.90 45 5.6 9
250 M3BM 355 LKB 3GBM 351 820-•QA 2975 95.5 95.5 0.90 0.90 56 6.1 11
315 M3BM 355 LKC 3GBM 351 830-•QA 2973 96.0 96.1 0.91 0.92 69 6.0 11
335 M3BM 355 LKD 3GBM 351 840-•QA 2972 96.0 96.1 0.91 0.92 74 6.0 12
4)
355 M3BM 400 LA 3GBM 401 510-•QA 2980 96.0 95.9 0.90 0.90 79 6.3 16
4)
400 M3BM 400 LB 3GBM 401 520-•QA 2978 96.2 96.2 0.91 0.91 88 6.2 15

1 450 4)
M3BM
3000 r/min = 2 poles
400 LC 3GBM 401 530-•QA 2978 96.4
3300 V 50 Hz
96.4 0.91 0.92 98 6.4 17

160 M3BM 315 LKA 3GBM 311 810-•RA 2969 94.9 94.9 0.92 0.92 32 6.1 5
200 M3BM 355 LKA 3GBM 351 810-•RA 2978 95.1 94.9 0.89 0.88 41 6.3 10
250 M3BM 355 LKB 3GBM 351 820-•RA 2975 95.5 95.5 0.90 0.90 51 6.1 10
315 M3BM 355 LKC 3GBM 351 830-•RA 2975 96.0 96.0 0.91 0.92 63 6.4 11
335 M3BM 355 LKD 3GBM 351 840-•RA 2975 96.2 96.2 0.91 0.92 67 6.5 11
4)
355 M3BM 400 LA 3GBM 401 510-•RA 2979 96.1 96.0 0.90 0.90 72 6.3 14
4)
400 M3BM 400 LB 3GBM 401 520-•RA 2978 96.2 96.1 0.91 0.91 80 6.2 14
4)
450 M3BM 400 LC 3GBM 401 530-•RA 2977 96.4 96.4 0.91 0.92 90 6.2 14
3000 r/min = 2 poles 6000 V 50 Hz
250 M3BM 355 LKA 3GBM 351 810-•TA 2975 95.3 95.4 0.91 0.91 28 6.1 5
280 M3BM 355 LKB 3GBM 351 820-•TA 2975 95.6 95.7 0.91 0.92 31 6.2 5
4)
315 M3BM 400 LA 3GBM 401 510-•TA 2981 95.5 95.4 0.89 0.88 36 6.4 8
4)
355 M3BM 400 LB 3GBM 401 520-•TA 2979 95.9 95.8 0.91 0.91 39 6.3 7
4)
400 M3BM 400 LC 3GBM 401 530-•TA 2978 96.0 96.0 0.91 0.91 44 6.2 8
4)
425 M3BM 400 LD 3GBM 401 540-•TA 2978 96.2 96.2 0.91 0.92 47 6.3 8
3000 r/min = 2 poles 6600 V 50 Hz
280 M3BM 355 LKA 3GBM 351 810-•SA 2976 95.5 95.6 0.91 0.92 28 6.5 5
4)
315 M3BM 400 LA 3GBM 401 510-•SA 2980 95.6 95.4 0.90 0.89 32 6.4 7
4)
355 M3BM 400 LB 3GBM 401 520-•SA 2980 95.8 95.7 0.91 0.91 36 6.3 7
4)
400 M3BM 400 LC 3GBM 401 530-•SA 2979 96.1 96.1 0.91 0.91 40 6.5 7
4)
425 M3BM 400 LD 3GBM 401 540-•SA 2978 96.2 96.2 0.91 0.92 42 6.5 7
1) 3)
The given values of load inertia assume two starts from cold and The sound pressure levels are presented at no-load. The magnetic
one start from warm conditions in successions against quadratic noise level of 2- and 4-pole motors is typically low compared to
load torque with 90% of the rated torque at the rated speed and at the fan noise, resulting no increase in the noise level on-load. The
80% of the rated voltage. variation and measuring tolerance of the figures is +3 dB(A).
2) 4)
Starting time with given values of the load inertia from cold Unidirectional fan construction as standard. Direction of rotation
condition in succession against quadratic load torque with 90% of must be stated when ordering, see variant codes 044 and 045.
the rated torque at the rated speed and at rated voltage.

The bullet in the product code indicates choice of mounting


arrangement (see ordering information page).

18 ABB/ BU Machines / HV Induction motors IEC catalogue / Standard motors EN 05-2006


HV Process performance cast iron motors
Technical data for totally enclosed squirrel
cage three phase motors
IP 55 – IC 411 – Insulation class F, temperature rise class B
Torque
Load Starting Maximum Sound
TN TS Tmax Power inertia time stalling Rotor Rotor Motor pressure
Output Motor type factor 1)
cold 2) time hot inertia weight weight level LP 3)
kW Nm TN TN cos ϕk kgm2 s s kgm2 kg kg dB(A)

3000 r/min = 2 poles 3000 V 50 Hz


132 M3BM 315 LKA 424 1.2 2.4 0.17 11 8 16 2.2 240 1240 78
160 M3BM 315 LKB 514 1.3 2.5 0.16 13 8 16 2.3 250 1270 78
200 M3BM 355 LKA 642 0.8 2.2 0.13 15 11 22 2.7 280 1680 83
250 M3BM 355 LKB 802 0.9 2.4 0.13 16 8 16 3.2 300 1780 83
315 M3BM 355 LKC 1012 1.0 2.2 0.13 20 8 16 5.0 390 2160 83
335 M3BM 355 LKD 1076 1.0 2.3 0.14 19 7 14 5.5 410 2240 83
4)
355 M3BM 400 LA 1138 0.9 2.4 0.13 26 10 20 6.4 460 2420 79
4)
400 M3BM 400 LB 1283 1.0 2.3 0.14 32 10 20 8.0 520 2670 79
450 4)
M3BM
3000 r/min = 2 poles
400 LC 1443 1.1 2.3 0.14 34
3300 V 50 Hz
9 18 9.6 580 2900 79
1
160 M3BM 315 LKA 515 1.2 2.3 0.17 13 8 16 2.3 250 1280 78
200 M3BM 355 LKA 641 0.9 2.5 0.13 16 10 20 2.7 280 1680 83
250 M3BM 355 LKB 802 0.9 2.4 0.13 18 9 16 3.2 300 1780 83
315 M3BM 355 LKC 1011 1.1 2.4 0.14 20 7 14 5.0 390 2140 83
335 M3BM 355 LKD 1075 1.1 2.4 0.13 21 7 14 5.5 410 2250 83
4)
355 M3BM 400 LA 1138 1.0 2.3 0.12 25 9 18 6.4 460 2440 79
4)
400 M3BM 400 LB 1283 1.0 2.3 0.13 27 9 18 8.0 520 2660 79
4)
450 M3BM 400 LC 1444 1.1 2.2 0.14 32 9 18 9.6 570 2910 79
3000 r/min = 2 poles 6000 V 50 Hz
250 M3BM 355 LKA 803 1.0 2.3 0.15 15 8 16 4.6 370 2010 83
280 M3BM 355 LKB 899 1.1 2.3 0.15 18 8 16 5.5 410 2200 83
4)
315 M3BM 400 LA 1009 1.0 2.4 0.14 23 10 20 5.6 430 2260 79
4)
355 M3BM 400 LB 1138 1.0 2.3 0.14 27 10 20 7.2 490 2500 79
4)
400 M3BM 400 LC 1283 1.0 2.3 0.14 31 10 20 8.0 520 2620 79
4)
425 M3BM 400 LD 1363 1.1 2.3 0.14 35 10 20 9.2 560 2800 79
3000 r/min = 2 poles 6600 V 50 Hz
280 M3BM 355 LKA 898 1.1 2.4 0.15 13 6 12 5.5 410 2190 83
4)
315 M3BM 400 LA 1009 1.0 2.4 0.14 24 10 20 5.6 430 2260 79
4)
355 M3BM 400 LB 1138 1.0 2.3 0.14 26 10 20 7.2 490 2490 79
4)
400 M3BM 400 LC 1282 1.1 2.4 0.14 30 9 18 8.0 520 2620 79
4)
425 M3BM 400 LD 1363 1.2 2.3 0.15 33 9 18 9.2 560 2800 79

ABB/ BU Machines / HV Induction motors IEC catalogue / Standard motors EN 05-2006 19


HV Process performance cast iron motors
Technical data for totally enclosed squirrel
cage three phase motors
IP 55 – IC 411 – Insulation class F, temperature rise class B
Efficiency Power factor Current
Full 3/4 Full 3/4 IN IS I0
Output Motor type Product code Speed load load load load
kW r/min 100% 75% 100% 75% A IN A

1500 r/min = 4 poles 3000 V 50 Hz


110 M3BM 315 LKA 3GBM 312 810-•QA 1488 94.7 94.3 0.83 0.79 27 6.2 11
132 M3BM 315 LKB 3GBM 312 820-•QA 1484 94.7 94.7 0.84 0.82 32 5.2 11
160 M3BM 315 LKC 3GBM 312 830-•QA 1485 95.0 94.9 0.87 0.85 37 6.3 11
200 M3BM 315 LKD 3GBM 312 840-•QA 1484 95.3 95.4 0.87 0.85 46 6.4 14
250 M3BM 355 LKA 3GBM 352 810-•QA 1490 95.6 95.4 0.83 0.80 61 6.2 23
315 M3BM 355 LKB 3GBM 352 820-•QA 1489 95.9 95.8 0.84 0.81 76 6.0 27
355 M3BM 355 LKC 3GBM 352 830-•QA 1488 96.1 96.0 0.84 0.82 85 6.1 29
400 M3BM 355 LKD 3GBM 352 840-•QA 1489 96.3 96.3 0.85 0.83 94 6.2 30

1 450
500
M3BM
M3BM
400 LA
400 LB
3GBM
3GBM
402 510-•QA
402 520-•QA
1490
1489
96.7
96.5
96.7
96.4
0.85
0.85
0.83
0.83
105
118
6.4
6.3
33
37
530 M3BM 400 LC 3GBM 402 530-•QA 1490 96.6 96.5 0.85 0.83 124 6.5 38
1500 r/min = 4 poles 3300 V 50 Hz
132 M3BM 315 LKA 3GBM 312 810-•RA 1488 94.9 94.6 0.81 0.76 30 6.2 13
160 M3BM 315 LKB 3GBM 312 820-•RA 1484 95.1 95.1 0.84 0.81 35 5.5 12
200 M3BM 315 LKC 3GBM 312 830-•RA 1484 95.3 95.4 0.87 0.85 42 6.4 12
250 M3BM 355 LKA 3GBM 352 810-•RA 1489 95.6 95.5 0.83 0.80 55 6.1 20
315 M3BM 355 LKB 3GBM 352 820-•RA 1490 95.8 95.7 0.83 0.79 70 6.4 27
355 M3BM 355 LKC 3GBM 352 830-•RA 1489 96.0 96.0 0.83 0.80 78 6.4 28
400 M3BM 355 LKD 3GBM 352 840-•RA 1489 96.3 96.2 0.85 0.82 86 6.4 28
450 M3BM 400 LA 3GBM 402 510-•RA 1489 96.7 96.7 0.85 0.83 96 6.1 29
500 M3BM 400 LB 3GBM 402 520-•RA 1490 96.5 96.4 0.85 0.82 107 6.5 35
530 M3BM 400 LC 3GBM 402 530-•RA 1489 96.6 96.5 0.85 0.84 112 6.4 34
1500 r/min = 4 poles 6000 V 50 Hz
250 M3BM 355 LKA 3GBM 352 810-•TA 1486 95.5 95.5 0.83 0.80 30 5.7 11
315 M3BM 355 LKB 3GBM 352 820-•TA 1487 96.0 95.9 0.83 0.79 38 6.4 15
355 M3BM 400 LA 3GBM 402 510-•TA 1489 96.2 96.2 0.85 0.83 42 6.2 13
400 M3BM 400 LB 3GBM 402 520-•TA 1489 96.4 96.4 0.85 0.83 47 6.4 15
450 M3BM 400 LC 3GBM 402 530-•TA 1489 96.2 96.2 0.86 0.84 53 6.2 16
500 M3BM 400 LD 3GBM 402 540-•TA 1490 96.4 96.4 0.85 0.83 59 6.4 18
1500 r/min = 4 poles 6600 V 50 Hz
250 M3BM 355 LKA 3GBM 352 810-•SA 1488 95.5 95.4 0.82 0.78 28 6.1 11
315 M3BM 355 LKB 3GBM 352 820-•SA 1487 95.9 95.9 0.83 0.80 35 6.3 13
355 M3BM 400 LA 3GBM 402 510-•SA 1489 96.2 96.2 0.85 0.83 38 6.1 12
400 M3BM 400 LB 3GBM 402 520-•SA 1489 96.3 96.3 0.85 0.83 43 6.2 13
450 M3BM 400 LC 3GBM 402 530-•SA 1489 96.2 96.2 0.85 0.83 48 6.4 15
500 M3BM 400 LD 3GBM 402 540-•SA 1490 96.4 96.4 0.85 0.83 53 6.5 17
1) 3)
The given values of load inertia assume three starts from cold and The sound pressure levels are presented at no-load. The magnetic
two starts from warm conditions in successions against quadratic noise level of 2- and 4-pole motors is typically low compared to
load torque with 90% of the rated torque at the rated speed and at the fan noise, resulting no increase in the noise level on-load. The
80% of the rated voltage. variation and measuring tolerance of the figures is +3 dB(A).
2)
Starting time with given values of the load inertia from cold
condition in succession against quadratic load torque with 90% of
the rated torque at the rated speed and at rated voltage.

The bullet in the product code indicates choice of mounting


arrangement (see ordering information page).

20 ABB/ BU Machines / HV Induction motors IEC catalogue / Standard motors EN 05-2006


HV Process performance cast iron motors
Technical data for totally enclosed squirrel
cage three phase motors
IP 55 – IC 411 – Insulation class F, temperature rise class B
Torque
Load Starting Maximum Sound
TN TS Tmax Power inertia time stalling Rotor Rotor Motor pressure
Output Motor type factor 1)
cold 2) time hot inertia weight weight level LP 3)
kW Nm TN TN cos ϕk kgm2 s s kgm2 kg kg dB(A)

1500 r/min = 4 poles 3000 V 50 Hz


110 M3BM 315 LKA 706 1.6 2.3 0.21 50 9 20 2.0 220 1190 73
132 M3BM 315 LKB 849 1.3 1.9 0.21 53 10 20 2.0 220 1190 73
160 M3BM 315 LKC 1029 1.7 2.2 0.21 69 8 16 3.2 260 1190 73
200 M3BM 315 LKD 1287 1.8 2.2 0.21 78 7 14 3.9 300 1290 73
250 M3BM 355 LKA 1603 1.3 2.2 0.17 86 8 16 6.4 400 1860 74
315 M3BM 355 LKB 2021 1.3 2.1 0.17 92 7 14 7.6 450 1990 74
355 M3BM 355 LKC 2278 1.4 2.1 0.17 105 7 14 8.4 480 2090 74
400 M3BM 355 LKD 2566 1.4 2.2 0.17 120 7 14 10.4 550 2310 74
450
500
M3BM
M3BM
400 LA
400 LB
2855
3206
1.5
1.5
2.1
2.1
0.16
0.16
125
134
6
6
12
12
14.4
14.4
660
660
2880
2870
74
79 1
530 M3BM 400 LC 3398 1.5 2.1 0.16 147 6 12 16.2 710 3040 79
1500 r/min = 4 poles 3300 V 50 Hz
132 M3BM 315 LKA 847 1.7 2.3 0.21 70 10 20 2.0 220 1190 73
160 M3BM 315 LKB 1029 1.5 2.0 0.21 70 10 20 2.3 240 1260 73
200 M3BM 315 LKC 1287 1.8 2.2 0.21 78 7 14 3.9 300 1290 73
250 M3BM 355 LKA 1603 1.3 2.2 0.17 83 8 16 6.4 400 1860 74
315 M3BM 355 LKB 2019 1.5 2.3 0.17 87 6 12 7.6 450 1970 74
355 M3BM 355 LKC 2277 1.5 2.2 0.17 98 6 12 8.4 480 2070 74
400 M3BM 355 LKD 2565 1.5 2.2 0.17 107 6 12 10.4 550 2300 74
450 M3BM 400 LA 2886 1.4 2.0 0.16 114 6 12 13.2 620 2760 74
500 M3BM 400 LB 3025 1.5 2.1 0.16 140 6 10 14.4 660 2850 79
530 M3BM 400 LC 3398 1.5 2.1 0.16 143 6 11 16.8 730 3100 79
1500 r/min = 4 poles 6000 V 50 Hz
250 M3BM 355 LKA 1606 1.2 2.1 0.17 95 9 20 4.6 380 2010 74
315 M3BM 355 LKB 2022 1.5 2.3 0.17 110 7 18 5.9 440 2290 74
355 M3BM 400 LA 2277 1.4 2.1 0.17 110 7 14 12.0 600 2590 74
400 M3BM 400 LB 2565 1.5 2.1 0.17 111 6 12 13.2 640 2720 74
450 M3BM 400 LC 2887 1.5 2.1 0.17 122 6 12 14.4 670 2840 79
500 M3BM 400 LD 3206 1.6 2.1 0.17 138 6 12 15.6 700 2950 79
1500 r/min = 4 poles 6600 V 50 Hz
250 M3BM 355 LKA 1605 1.4 2.3 0.17 93 8 16 4.6 380 2010 74
315 M3BM 355 LKB 2023 1.4 2.3 0.17 105 7 14 5.9 440 2280 74
355 M3BM 400 LA 2277 1.4 2.1 0.17 110 7 14 12.0 600 2600 74
400 M3BM 400 LB 2566 1.5 2.1 0.17 125 7 14 13.2 640 2710 74
450 M3BM 400 LC 2886 1.6 2.1 0.17 128 6 12 14.4 670 2830 79
500 M3BM 400 LD 3205 1.6 2.1 0.17 141 6 12 15.6 700 2940 79

ABB/ BU Machines / HV Induction motors IEC catalogue / Standard motors EN 05-2006 21


HV Process performance cast iron motors
Technical data for totally enclosed squirrel
cage three phase motors
IP 55 – IC 411 – Insulation class F, temperature rise class B
Efficiency Power factor Current
Full 3/4 Full 3/4 IN IS I0
Output Motor type Product code Speed load load load load
kW r/min 100% 75% 100% 75% A IN A

1000 r/min = 6 poles 3000 V 50 Hz


110 M3BM 315 LKA 3GBM 313 810-•QA 987 94.4 94.6 0.79 0.76 28 5.3 12
132 M3BM 315 LKB 3GBM 313 820-•QA 986 94.7 94.9 0.79 0.75 34 5.4 14
150 M3BM 315 LKC 3GBM 313 830-•QA 987 95.1 95.2 0.80 0.75 38 5.7 16
160 M3BM 355 LKA 3GBM 353 810-•QA 992 95.3 95.2 0.74 0.68 43 5.5 22
200 M3BM 355 LKB 3GBM 353 820-•QA 990 95.7 95.7 0.78 0.74 52 5.3 22
250 M3BM 355 LKC 3GBM 353 830-•QA 991 96.0 96.0 0.78 0.74 64 5.5 28
315 M3BM 400 L 3GBM 403 500-•QA 991 96.1 96.2 0.81 0.78 78 5.9 29
355 M3BM 400 LA 3GBM 403 510-•QA 991 96.3 96.4 0.82 0.79 87 5.9 31

1 400
425
M3BM
M3BM
400 LB
400 LC
3GBM
3GBM
403 520-•QA
403 530-•QA
991
991
96.4
96.4
96.5
96.5
0.82
0.82
0.79
0.79
98
104
6.2
6.3
36
38
1000 r/min = 6 poles 3300 V 50 Hz
110 M3BM 315 LKA 3GBM 313 810-•RA 988 94.5 94.6 0.79 0.74 26 5.6 11
132 M3BM 315 LKB 3GBM 313 820-•RA 987 94.7 94.9 0.79 0.75 31 5.6 13
150 M3BM 315 LKC 3GBM 313 830-•RA 987 95.1 95.2 0.80 0.75 35 5.7 15
160 M3BM 355 LKA 3GBM 353 810-•RA 992 95.3 95.1 0.73 0.67 40 5.7 21
200 M3BM 355 LKB 3GBM 353 820-•RA 990 95.6 95.7 0.78 0.74 47 5.3 20
250 M3BM 355 LKC 3GBM 353 830-•RA 990 95.9 96.0 0.79 0.75 58 5.3 24
315 M3BM 400 L 3GBM 403 500-•RA 990 96.0 96.2 0.81 0.79 71 5.7 25
355 M3BM 400 LA 3GBM 403 510-•RA 991 96.2 96.3 0.81 0.79 79 6.0 29
400 M3BM 400 LB 3GBM 403 520-•RA 991 96.4 96.5 0.82 0.79 89 6.0 32
425 M3BM 400 LC 3GBM 403 530-•RA 991 96.5 96.6 0.82 0.78 95 6.4 35
1000 r/min = 6 poles 6000 V 50 Hz
220 M3BM 355 LKA 3GBM 353 810-•TA 992 95.5 95.5 0.79 0.74 28 6.3 12
250 M3BM 355 LKB 3GBM 353 820-•TA 991 95.6 95.7 0.80 0.76 31 6.0 13
280 M3BM 400 L 3GBM 403 500-•TA 991 96.0 96.0 0.79 0.75 36 5.6 15
315 M3BM 400 LA 3GBM 403 510-•TA 992 96.2 96.1 0.79 0.75 40 5.8 17
355 M3BM 400 LB 3GBM 403 520-•TA 991 96.3 96.3 0.80 0.76 45 5.6 18
375 M3BM 400 LC 3GBM 403 530-•TA 991 96.3 96.3 0.79 0.76 47 5.8 19
1000 r/min = 6 poles 6600 V 50 Hz
250 M3BM 355 LKA 3GBM 353 810-•SA 992 95.6 95.6 0.79 0.75 29 6.3 13
280 M3BM 400 L 3GBM 403 500-•SA 991 95.9 95.9 0.78 0.74 33 5.6 14
315 M3BM 400 LA 3GBM 403 510-•SA 992 96.2 96.1 0.78 0.73 37 6.1 16
355 M3BM 400 LB 3GBM 403 520-•SA 991 96.3 96.3 0.79 0.75 41 5.8 17
375 M3BM 400 LC 3GBM 403 530-•SA 992 96.4 96.3 0.79 0.75 43 5.9 18
1) 3)
The given values of load inertia assume three starts from cold and The sound pressure levels are presented at no-load. Sound level
two starts from warm conditions in successions against quadratic values of 6...12-pole motors at no-load are typically 1...3 dB(A)
load torque with 90% of the rated torque at the rated speed and at higher than the corresponding values at no-load. The variation and
80% of the rated voltage. measuring tolerance of the figures is +3 dB(A).
2)
Starting time with given values of the load inertia from cold
condition in succession against quadratic load torque with 90% of
the rated torque at the rated speed and at rated voltage.

The bullet in the product code indicates choice of mounting


arrangement (see ordering information page).

22 ABB/ BU Machines / HV Induction motors IEC catalogue / Standard motors EN 05-2006


HV Process performance cast iron motors
Technical data for totally enclosed squirrel
cage three phase motors
IP 55 – IC 411 – Insulation class F, temperature rise class B
Torque
Load Starting Maximum Sound
TN TS Tmax Power inertia time stalling Rotor Rotor Motor pressure
Output Motor type factor 1)
cold 2) time hot inertia weight weight level LP 3)
kW Nm TN TN cos ϕk kgm2 s s kgm2 kg kg dB(A)

1000 r/min = 6 poles 3000 V 50 Hz


110 M3BM 315 LKA 1065 1.5 2.0 0.22 127 10 20 3.2 270 1170 65
132 M3BM 315 LKB 1278 1.6 2.1 0.22 144 9 18 3.7 290 1240 65
150 M3BM 315 LKC 1452 1.7 2.2 0.22 156 8 20 4.6 340 1380 65
160 M3BM 355 LKA 1541 1.5 2.1 0.19 178 10 20 4.8 350 1660 70
200 M3BM 355 LKB 1928 1.4 2.0 0.19 205 10 20 6.4 410 1850 70
250 M3BM 355 LKC 2410 1.5 2.0 0.19 275 10 20 8.0 480 2040 70
315 M3BM 400 L 3036 1.6 2.0 0.18 335 9 18 16.2 680 2500 75
355 M3BM 400 LA 3422 1.6 2.0 0.18 370 9 18 19.8 770 2740 75
400
425
M3BM
M3BM
400 LB
400 LC
3854
4094
1.7
1.8
2.0
2.1
0.19
0.19
400
435
8
8
18
18
23.4
26.1
870
940
2970
3130
75
75 1
1000 r/min = 6 poles 3300 V 50 Hz
110 M3BM 315 LKA 1064 1.6 2.1 0.22 136 10 20 3.2 270 1170 65
132 M3BM 315 LKB 1277 1.7 2.1 0.22 149 9 18 3.7 290 1240 65
150 M3BM 315 LKC 1452 1.7 2.2 0.22 175 9 20 4.6 340 1380 65
160 M3BM 355 LKA 1540 1.5 2.2 0.19 184 10 20 4.8 350 1660 70
200 M3BM 355 LKB 1928 1.4 2.0 0.19 204 10 20 6.4 410 1850 70
250 M3BM 355 LKC 2412 1.4 1.9 0.19 258 10 20 8.0 480 2040 70
315 M3BM 400 L 3038 1.5 1.9 0.18 350 9 18 16.2 680 2500 75
355 M3BM 400 LA 3422 1.6 2.0 0.19 382 9 18 19.8 770 2730 75
400 M3BM 400 LB 3855 1.7 2.0 0.19 435 9 18 23.4 870 2970 75
425 M3BM 400 LC 4094 1.8 2.1 0.19 445 8 18 26.1 940 3140 75
1000 r/min = 6 poles 6000 V 50 Hz
220 M3BM 355 LKA 2118 1.8 2.3 0.21 198 7 14 9.6 540 2160 70
250 M3BM 355 LKB 2409 1.7 2.1 0.21 210 7 14 10.4 570 2250 70
280 M3BM 400 L 2697 1.3 2.0 0.16 290 10 20 11.4 590 2530 75
315 M3BM 400 LA 3033 1.4 2.1 0.17 342 10 20 13.2 640 2700 75
355 M3BM 400 LB 3421 1.4 2.0 0.17 367 10 20 14.4 680 2820 75
375 M3BM 400 LC 3613 1.4 2.0 0.17 410 10 20 15.6 720 2940 75
1000 r/min = 6 poles 6600 V 50 Hz
250 M3BM 355 LKA 2408 1.8 2.2 0.21 193 6 12 10.4 570 2250 70
280 M3BM 400 L 2697 1.3 2.0 0.16 290 10 20 10.8 570 2460 75
315 M3BM 400 LA 3032 1.5 2.2 0.17 369 10 20 13.2 640 2700 75
355 M3BM 400 LB 3419 1.4 2.0 0.17 390 10 20 14.4 680 2820 75
375 M3BM 400 LC 3611 1.5 2.1 0.17 427 10 20 15.6 720 2940 75

ABB/ BU Machines / HV Induction motors IEC catalogue / Standard motors EN 05-2006 23


HV Process performance cast iron motors
Technical data for totally enclosed squirrel
cage three phase motors
IP 55 – IC 411 – Insulation class F, temperature rise class B
Efficiency Power factor Current
Full 3/4 Full 3/4 IN IS I0
Output Motor type Product code Speed load load load load
kW r/min 100% 75% 100% 75% A IN A

750 r/min = 8 poles 3000 V 50 Hz


200 M3BM 400 LA 3GBM 404 510-•QA 742 95.1 95.2 0.79 0.76 51 5.3 21
220 M3BM 400 LB 3GBM 404 520-•QA 742 95.3 95.4 0.79 0.75 56 5.5 24
250 M3BM 400 LC 3GBM 404 530-•QA 742 95.4 95.6 0.80 0.76 63 5.4 25
280 M3BM 400 LD 3GBM 404 540-•QA 741 95.4 95.6 0.80 0.77 70 5.2 26
300 M3BM 400 LE 3GBM 404 540-•QA 741 95.6 95.8 0.80 0.77 75 5.4 29
750 r/min = 8 poles 3300 V 50 Hz
200 M3BM 400 LA 3GBM 404 510-•RA 742 95.0 95.2 0.79 0.76 46 5.2 19
220 M3BM 400 LB 3GBM 404 520-•RA 742 95.2 95.4 0.80 0.76 51 5.3 20

1 250
280
M3BM
M3BM
400 LC
400 LD
3GBM
3GBM
404 530-•RA
404 540-•RA
741
741
95.3
95.5
95.6
95.7
0.80
0.80
0.78
0.77
57
64
5.0
5.5
21
25
300 M3BM 400 LE 3GBM 404 550-•RA 741 95.5 95.7 0.80 0.77 69 5.5 27
750 r/min = 8 poles 6000 V 50 Hz
160 M3BM 400 LA 3GBM 404 510-•TA 741 94.4 94.4 0.76 0.71 21 5.2 10
180 M3BM 400 LB 3GBM 404 520-•TA 740 94.5 94.6 0.77 0.72 24 5.0 11
200 M3BM 400 LC 3GBM 404 530-•TA 740 94.7 94.8 0.77 0.73 26 5.1 12
220 M3BM 400 LD 3GBM 404 540-•TA 740 94.8 95.0 0.78 0.74 29 5.0 12
250 M3BM 400 LE 3GBM 404 550-•TA 740 95.1 95.1 0.77 0.72 33 5.3 15
750 r/min = 8 poles 6600 V 50 Hz
160 M3BM 400 LA 3GBM 404 510-•SA 741 94.5 94.4 0.76 0.71 20 5.4 9
180 M3BM 400 LB 3GBM 404 520-•SA 741 94.5 94.5 0.76 0.70 22 5.3 11
200 M3BM 400 LC 3GBM 404 530-•SA 740 94.6 94.8 0.78 0.74 24 4.8 10
220 M3BM 400 LD 3GBM 404 540-•SA 740 94.9 94.9 0.77 0.72 26 5.2 12
250 M3BM 400 LE 3GBM 404 550-•SA 741 95.1 95.1 0.76 0.71 30 5.5 14
1) 3)
The given values of load inertia assume three starts from cold and The sound pressure levels are presented at no-load. Sound level
two starts from warm conditions in successions against quadratic values of 6...12-pole motors at no-load are typically 1...3 dB(A)
load torque with 90% of the rated torque at the rated speed and at higher than the corresponding values at no-load. The variation and
80% of the rated voltage. measuring tolerance of the figures is +3 dB(A).
2)
Starting time with given values of the load inertia from cold
condition in succession against quadratic load torque with 90% of
the rated torque at the rated speed and at rated voltage.

The bullet in the product code indicates choice of mounting


arrangement (see ordering information page).

24 ABB/ BU Machines / HV Induction motors IEC catalogue / Standard motors EN 05-2006


HV Process performance cast iron motors
Technical data for totally enclosed squirrel
cage three phase motors
IP 55 – IC 411 – Insulation class F, temperature rise class B
Torque
Load Starting Maximum Sound
TN TS Tmax Power inertia time stalling Rotor Rotor Motor pressure
Output Motor type factor 1)
cold 2) time hot inertia weight weight level LP 3)
kW Nm TN TN cos ϕk kgm2 s s kgm2 kg kg dB(A)

750 r/min = 8 poles 3000 V 50 Hz


200 M3BM 400 LA 2575 1.0 2.1 0.15 390 11 22 14.4 630 2370 75
220 M3BM 400 LB 2831 1.1 2.3 0.14 425 10 20 16.2 680 2490 75
250 M3BM 400 LC 3219 1.1 2.2 0.14 480 10 20 19.8 780 2730 75
280 M3BM 400 LD 3610 1.1 2.1 0.14 530 10 20 21.6 830 2830 75
300 M3BM 400 LE 3866 1.1 2.1 0.14 565 10 20 23.4 870 2960 75
750 r/min = 8 poles 3300 V 50 Hz
200 M3BM 400 LA 2575 1.0 2.1 0.15 390 11 22 14.4 630 2370 75
220 M3BM 400 LB 2833 1.1 2.1 0.14 425 10 20 16.2 680 2490 75
250
280
M3BM
M3BM
400 LC
400 LD
3223
3607
1.0
1.1
2.0
2.2
0.14
0.14
480
530
11
9
22
18
19.8
21.6
780
830
2720
2840
75
75
1
300 M3BM 400 LE 3865 1.1 2.2 0.14 565 9 18 23.4 870 2940 75
750 r/min = 8 poles 6000 V 50 Hz
160 M3BM 400 LA 2062 1.1 2.2 0.16 320 10 20 10.2 560 2380 75
180 M3BM 400 LB 2322 1.0 2.1 0.16 355 11 22 10.8 580 2450 75
200 M3BM 400 LC 2580 1.1 2.2 0.15 390 10 20 12.6 640 2620 75
220 M3BM 400 LD 2840 1.0 2.1 0.15 425 10 20 13.8 680 2740 75
250 M3BM 400 LE 3225 1.2 2.3 0.15 480 9 18 15.6 740 2920 75
750 r/min = 8 poles 6600 V 50 Hz
160 M3BM 400 LA 2061 1.1 2.3 0.16 320 10 20 10.8 580 2440 75
180 M3BM 400 LB 2319 1.1 2.3 0.16 355 10 20 10.8 580 2440 75
200 M3BM 400 LC 2583 1.0 2.0 0.16 390 11 22 12.6 640 2620 75
220 M3BM 400 LD 2838 1.1 2.2 0.15 425 10 20 13.8 680 2740 75
250 M3BM 400 LE 3223 1.2 2.3 0.15 480 9 18 15.6 740 2910 75

ABB/ BU Machines / HV Induction motors IEC catalogue / Standard motors EN 05-2006 25


HV Process performance cast iron motors
Technical data for totally enclosed squirrel
cage three phase motors
IP 55 – IC 411 – Insulation class F, temperature rise class B
Efficiency Power factor Current
Full 3/4 Full 3/4 IN IS I0
Output Motor type Product code Speed load load load load
kW r/min 100% 75% 100% 75% A IN A

600 r/min = 10 poles 3000 V 50 Hz


150 M3BM 400 LA 3GBM 405 510-•QA 593 94.1 93.9 0.72 0.67 43 4.7 22
160 M3BM 400 LB 3GBM 405 520-•QA 594 94.2 93.9 0.71 0.65 46 4.9 25
180 M3BM 400 LC 3GBM 405 530-•QA 593 94.3 94.0 0.71 0.65 51 4.9 27
200 M3BM 400 LD 3GBM 405 540-•QA 593 94.5 94.2 0.72 0.66 57 4.9 29
220 M3BM 400 LE 3GBM 405 550-•QA 593 94.6 94.2 0.71 0.64 63 5.2 35
600 r/min = 10 poles 3300 V 50 Hz
150 M3BM 400 LA 3GBM 405 510-•RA 593 94.1 93.8 0.71 0.66 39 4.8 20
160 M3BM 400 LB 3GBM 405 520-•RA 594 94.2 93.8 0.71 0.64 42 5.0 23

1 180
200
M3BM
M3BM
400 LC
400 LD
3GBM
3GBM
405 530-•RA
405 540-•RA
593
593
94.3
94.4
94.0
94.2
0.71
0.72
0.65
0.67
47
51
4.9
4.8
25
26
220 M3BM 400 LE 3GBM 405 550-•RA 593 94.5 94.3 0.72 0.66 57 5.0 30
500 r/min = 12 poles 3000 V 50 Hz
110 M3BM 400 LA 3GBM 406 510-•QA 494 93.1 92.8 0.66 0.60 34 4.3 19
120 M3BM 400 LB 3GBM 406 520-•QA 494 93.2 93.0 0.67 0.61 37 4.3 21
132 M3BM 400 LC 3GBM 406 530-•QA 494 93.4 93.1 0.67 0.61 41 4.3 23
150 M3BM 400 LD 3GBM 406 540-•QA 494 93.5 93.2 0.66 0.61 46 4.3 26
160 M3BM 400 LE 3GBM 406 550-•QA 494 93.7 93.2 0.66 0.59 50 4.6 29
500 r/min = 12 poles 3300 V 50 Hz
110 M3BM 400 LA 3GBM 406 510-•RA 494 93.1 92.7 0.66 0.60 31 4.4 18
120 M3BM 400 LB 3GBM 406 520-•RA 494 93.2 92.9 0.66 0.60 34 4.3 19
132 M3BM 400 LC 3GBM 406 530-•RA 494 93.4 93.1 0.67 0.61 37 4.3 21
150 M3BM 400 LD 3GBM 406 540-•RA 493 93.5 93.3 0.67 0.61 42 4.3 23
160 M3BM 400 LE 3GBM 406 550-•RA 494 93.7 93.3 0.66 0.60 45 4.4 25
1) 3)
The given values of load inertia assume three starts from cold and The sound pressure levels are presented at no-load. Sound level
two starts from warm conditions in successions against quadratic values of 6...12-pole motors at no-load are typically 1...3 dB(A)
load torque with 90% of the rated torque at the rated speed and at higher than the corresponding values at no-load. The variation and
80% of the rated voltage. measuring tolerance of the figures is +3 dB(A).
2)
Starting time with given values of the load inertia from cold
condition in succession against quadratic load torque with 90% of
the rated torque at the rated speed and at rated voltage.

The bullet in the product code indicates choice of mounting


arrangement (see ordering information page).

26 ABB/ BU Machines / HV Induction motors IEC catalogue / Standard motors EN 05-2006


HV Process performance cast iron motors
Technical data for totally enclosed squirrel
cage three phase motors
IP 55 – IC 411 – Insulation class F, temperature rise class B
Torque
Load Starting Maximum Sound
TN TS Tmax Power inertia time stalling Rotor Rotor Motor pressure
Output Motor type factor 1)
cold 2) time hot inertia weight weight level LP 3)
kW Nm TN TN cos ϕk kgm2 s s kgm2 kg kg dB(A)

600 r/min = 10 poles 3000 V 50 Hz


150 M3BM 400 LA 2415 1.0 2.0 0.15 515 13 26 16.2 680 2480 75
160 M3BM 400 LB 2574 1.1 2.1 0.15 545 12 24 17.1 710 2540 75
180 M3BM 400 LC 2897 1.1 2.1 0.15 605 11 22 18.9 750 2660 75
200 M3BM 400 LD 3220 1.1 2.1 0.14 670 11 22 21.6 830 2840 75
220 M3BM 400 LE 3540 1.2 2.2 0.14 730 10 20 23.4 880 2950 75
600 r/min = 10 poles 3300 V 50 Hz
150 M3BM 400 LA 2414 1.0 2.0 0.15 515 12 24 16.2 680 2470 75
160 M3BM 400 LB 2573 1.1 2.2 0.15 545 11 22 17.1 710 2530 75
180
200
M3BM
M3BM
400 LC
400 LD
2897
3222
1.1
1.0
2.1
2.0
0.15
0.14
605
670
11
12
22
24
18.9
21.6
750
830
2650
2830
75
75
1
220 M3BM 400 LE 3542 1.1 2.1 0.14 730 11 22 23.4 880 2950 75
500 r/min = 12 poles 3000 V 50 Hz
110 M3BM 400 LA 2126 1.0 2.0 0.14 595 14 28 16.2 680 2470 75
120 M3BM 400 LB 2320 1.0 2.0 0.14 650 14 28 18.0 730 2580 75
132 M3BM 400 LC 2553 1.0 2.0 0.14 710 14 28 19.8 780 2700 75
150 M3BM 400 LD 2902 1.1 2.0 0.14 795 13 26 21.6 830 2820 75
160 M3BM 400 LE 3092 1.1 2.1 0.14 845 12 24 24.3 900 3000 75
500 r/min = 12 poles 3300 V 50 Hz
110 M3BM 400 LA 2125 1.1 2.1 0.14 595 13 26 16.2 680 2460 75
120 M3BM 400 LB 2320 1.0 2.0 0.14 650 14 28 18.0 730 2580 75
132 M3BM 400 LC 2553 1.0 2.0 0.14 710 14 28 19.8 780 2700 75
150 M3BM 400 LD 2903 1.0 1.9 0.14 795 14 28 21.6 830 2820 75
160 M3BM 400 LE 3094 1.1 2.0 0.14 845 13 26 24.3 900 3000 75

ABB/ BU Machines / HV Induction motors IEC catalogue / Standard motors EN 05-2006 27


Non-sparking and Dust Ignition Proof HV Cast iron motors
Technical data for totally enclosed squirrel
cage three phase motors
IP 55 – IC 411 – Insulation class F, temperature rise class B
Efficiency Power factor Current
Full 3/4 Full 3/4 IN IS I0
Output Motor type Product code Speed load load load load
kW r/min 100% 75% 100% 75% A IN A

3000 r/min = 2 poles 3000 V 50 Hz


132 M3GM 315 LKA 3GGM 311 810-•QA 2971 94.7 94.5 0.92 0.92 29 6.3 5
160 M3GM 315 LKB 3GGM 311 820-•QA 2971 94.9 94.8 0.92 0.92 35 6.5 6
200 M3GM 355 LKA 3GGM 351 810-•QA 2974 95.0 94.9 0.9 0.9 45 5.6 9
250 M3GM 355 LKB 3GGM 351 820-•QA 2975 95.5 95.5 0.9 0.9 56 6.1 11
315 M3GM 355 LKC 3GGM 351 830-•QA 2973 96.0 96.1 0.91 0.92 69 6.0 11
335 M3GM 355 LKD 3GGM 351 840-•QA 2972 96.0 96.1 0.91 0.92 74 6.0 12
4)
355 M3GM 400 LA 3GGM 401 510-•QA 2980 96.0 95.9 0.9 0.9 79 6.3 16
4)
400 M3GM 400 LB 3GGM 401 520-•QA 2978 96.2 96.2 0.91 0.91 88 6.2 15

1 450 4)
M3GM
3000 r/min = 2 poles
400 LC 3GGM 401 530-•QA 2978 96.4
3300 V 50 Hz
96.4 0.91 0.92 98 6.4 17

160 M3GM 315 LKA 3GGM 311 810-•RA 2969 94.9 94.9 0.92 0.92 32 6.1 5
200 M3GM 355 LKA 3GGM 351 810-•RA 2978 95.1 94.9 0.89 0.88 41 6.3 10
250 M3GM 355 LKB 3GGM 351 820-•RA 2975 95.5 95.5 0.9 0.9 51 6.1 10
315 M3GM 355 LKC 3GGM 351 830-•RA 2975 96.0 96.0 0.91 0.92 63 6.4 11
335 M3GM 355 LKD 3GGM 351 840-•RA 2975 96.2 96.2 0.91 0.92 67 6.5 11
4)
355 M3GM 400 LA 3GGM 401 510-•RA 2979 96.1 96.0 0.9 0.9 72 6.3 14
4)
400 M3GM 400 LB 3GGM 401 520-•RA 2978 96.2 96.1 0.91 0.91 80 6.2 14
4)
450 M3GM 400 LC 3GGM 401 530-•RA 2977 96.4 96.4 0.91 0.92 90 6.2 14
3000 r/min = 2 poles 6000 V 50 Hz
250 M3GM 355 LKA 3GGM 351 810-•TA 2975 95.3 95.4 0.91 0.91 28 6.1 5
280 M3GM 355 LKB 3GGM 351 820-•TA 2975 95.6 95.7 0.91 0.92 31 6.2 5
4)
315 M3GM 400 LA 3GGM 401 510-•TA 2981 95.5 95.4 0.89 0.88 36 6.4 8
4)
355 M3GM 400 LB 3GGM 401 520-•TA 2979 95.9 95.8 0.91 0.91 39 6.3 7
4)
400 M3GM 400 LC 3GGM 401 530-•TA 2978 96.0 96 0.91 0.91 44 6.2 8
4)
425 M3GM 400 LD 3GGM 401 540-•TA 2978 96.2 96.2 0.91 0.92 47 6.3 8
3000 r/min = 2 poles 6600 V 50 Hz
280 M3GM 355 LKA 3GGM 351 810-•SA 2976 95.5 95.6 0.91 0.92 28 6.5 5
4)
315 M3GM 400 LA 3GGM 401 510-•SA 2980 95.6 95.4 0.9 0.89 32 6.4 7
4)
355 M3GM 400 LB 3GGM 401 520-•SA 2980 95.8 95.7 0.91 0.91 36 6.3 7
4)
400 M3GM 400 LC 3GGM 401 530-•SA 2979 96.1 96.1 0.91 0.91 40 6.5 7
4)
425 M3GM 400 LD 3GGM 401 540-•SA 2978 96.2 96.2 0.91 0.92 42 6.5 7

The bullet in the product code indicates choice of mounting


arrangement (see ordering information page).
1)
When ordering, the following variant codes have to be added to the product code acc. to
needs. The above prices INCLUDE the extra price acc. to variant code:
for non-sparking motors:
456 = Ex nA design, fulfilling IEC 60079-15, with certificate.
480 = EEx nA, fulfilling EN 50021.
for DIP motors:
453 = DIP according to EN 50281-1-1, T= 125°C, category 2D, IP65 (for zone 21)
805 = DIP according to IEC 61241-1-1, T= 125°C, IP65 (for zone 21)
452 = DIP according to EN 50281-1-1, T= 125°C, category 3D, IP55 (for zone 22)
454 = DIP according to EN 50281-1-1, T= 125°C, category 3D, IP65 (for zone 22)
804 = DIP according to IEC 61241-1-1, T= 125°C, IP55 (for zone 22)
806 = DIP according to IEC 61241-1-1, T= 125°C, IP65 (for zone 22)

28 ABB/ BU Machines / HV Induction motors IEC catalogue / Standard motors EN 05-2006


Non-sparking and Dust Ignition Proof HV Cast iron motors
Technical data for totally enclosed squirrel
cage three phase motors
IP 55 – IC 411 – Insulation class F, temperature rise class B
Torque
Load Starting Maximum Sound
TN TS Tmax Power inertia time stalling Rotor Rotor Motor pressure
Output Motor type factor 1)
cold 2) time hot inertia weight weight level LP 3)
kW Nm TN TN cos ϕk kgm2 s s kgm2 kg kg dB(A)

3000 r/min = 2 poles 3000 V 50 Hz


132 M3GM 315 LKA 424 1.2 2.4 0.17 11 8 16 2.2 240 1240 78
160 M3GM 315 LKB 514 1.3 2.5 0.17 13 8 16 2.3 250 1270 78
200 M3GM 355 LKA 642 0.8 2.2 0.13 15 11 22 2.7 280 1680 83
250 M3GM 355 LKB 802 0.9 2.4 0.13 16 8 16 3.2 300 1780 83
315 M3GM 355 LKC 1012 1.0 2.2 0.13 20 8 16 5 390 2160 83
335 M3GM 355 LKD 1076 1.0 2.3 0.14 19 7 14 5.5 410 2240 83
4)
355 M3GM 400 LA 1138 0.9 2.4 0.13 26 10 20 6.4 460 2420 79
4)
400 M3GM 400 LB 1283 1.0 2.3 0.14 32 10 20 8 520 2670 79
450 4)
M3GM
3000 r/min = 2 poles
400 LC 1443 1.1 2.3 0.14 34 9
3300 V 50 Hz
18 9.6 580 2900 79
1
160 M3GM 315 LKA 515 1.2 2.3 0.17 13 8 16 2.3 250 1280 78
200 M3GM 355 LKA 641 0.9 2.5 0.13 16 10 20 2.7 280 1680 83
250 M3GM 355 LKB 802 0.9 2.4 0.13 18 9 16 3.2 300 1780 83
315 M3GM 355 LKC 1011 1.1 2.4 0.14 20 7 14 5 390 2140 83
335 M3GM 355 LKD 1075 1.1 2.4 0.13 21 7 14 5.5 410 2250 83
4)
355 M3GM 400 LA 1138 1.0 2.3 0.13 25 9 18 6.4 460 2440 79
4)
400 M3GM 400 LB 1283 1.0 2.3 0.13 27 9 18 8 520 2660 79
4)
450 M3GM 400 LC 1444 1.1 2.2 0.14 32 9 18 9.6 570 2910 79
3000 r/min = 2 poles 6000 V 50 Hz
250 M3GM 355 LKA 803 1.0 2.3 0.15 15 8 16 4.6 370 2010 83
280 M3GM 355 LKB 899 1.1 2.3 0.15 18 8 16 5.5 410 2200 83
4)
315 M3GM 400 LA 1009 1.0 2.4 0.14 23 10 20 5.6 430 2260 79
4)
355 M3GM 400 LB 1138 1.0 2.3 0.14 27 10 20 7.2 490 2500 79
4)
400 M3GM 400 LC 1283 1.0 2.3 0.14 31 10 20 8 520 2620 79
4)
425 M3GM 400 LD 1363 1.1 2.3 0.14 35 10 20 9.2 560 2800 79
3000 r/min = 2 poles 6600 V 50 Hz
280 M3GM 355 LKA 898 1.1 2.4 0.15 13 6 12 5.5 410 2190 83
4)
315 M3GM 400 LA 1009 1.0 2.4 0.14 24 10 20 5.6 430 2260 79
4)
355 M3GM 400 LB 1138 1.0 2.3 0.14 26 10 20 7.2 490 2490 79
4)
400 M3GM 400 LC 1282 1.1 2.4 0.14 30 9 18 8 520 2620 79
4)
425 M3GM 400 LD 1363 1.2 2.3 0.15 33 9 18 9.2 560 2800 79

1) 3)
The given values of load inertia assume two starts from cold and The sound pressure levels are presented at no-load. The
one start from warm conditions in successions against quadratic magnetic noise level of 2- and 4-pole motors is typically low
load torque with 90% of the rated torque at the rated speed and compared to the fan noise, resulting no increase in the noise
at 80% of the rated voltage. level on-load. The variation and measuring tolerance of the
2)
figures is + 3 dB(A).
Starting time with given values of the load inertia from cold
4)
condition in succession against quadratic load torque with 90% Unidirectional fan construction as standard. Direction of rotation
of the rated torque at the rated speed and at rated voltage. must be stated when ordering, see variant codes 044 and 045.

ABB/ BU Machines / HV Induction motors IEC catalogue / Standard motors EN 05-2006 29


Non-sparking and Dust Ignition Proof HV Cast iron motors
Technical data for totally enclosed squirrel
cage three phase motors
IP 55 – IC 411 – Insulation class F, temperature rise class B
Efficiency Power factor Current
Full 3/4 Full 3/4 IN IS I0
Output Motor type Product code Speed load load load load
kW r/min 100% 75% 100% 75% A IN A

1500 r/min = 4 poles 3000 V 50 Hz


110 M3GM 315 LKA 3GGM 312 810-•QA 1488 94.7 94.3 0.83 0.79 27 6.2 11
132 M3GM 315 LKB 3GGM 312 820-•QA 1484 94.7 94.7 0.84 0.82 32 5.2 11
160 M3GM 315 LKC 3GGM 312 830-•QA 1485 95.0 94.9 0.87 0.85 37 6.3 11
200 M3GM 315 LKD 3GGM 312 840-•QA 1484 95.3 95.4 0.87 0.85 46 6.4 14
250 M3GM 355 LKA 3GGM 352 810-•QA 1490 95.6 95.4 0.83 0.8 61 6.2 23
315 M3GM 355 LKB 3GGM 352 820-•QA 1489 95.9 95.8 0.84 0.81 76 6.0 27
355 M3GM 355 LKC 3GGM 352 830-•QA 1488 96.1 96.0 0.84 0.82 85 6.1 29
400 M3GM 355 LKD 3GGM 352 840-•QA 1489 96.3 96.3 0.85 0.83 94 6.2 30

1 450
500
M3GM
M3GM
400 LA
400 LB
3GGM
3GGM
402 510-•QA
402 520-•QA
1490
1489
96.7
96.5
96.7
96.4
0.85
0.85
0.83
0.83
105
118
6.4
6.3
33
37
530 M3GM 400 LC 3GGM 402 530-•QA 1490 96.6 96.5 0.85 0.83 124 6.5 38
1500 r/min = 4 poles 3300 V 50 Hz
132 M3GM 315 LKA 3GGM 312 810-•RA 1488 94.9 94.6 0.81 0.76 30 6.2 13
160 M3GM 315 LKB 3GGM 312 820-•RA 1484 95.1 95.1 0.84 0.81 35 5.5 12
200 M3GM 315 LKC 3GGM 312 830-•RA 1484 95.3 95.4 0.87 0.85 42 6.4 12
250 M3GM 355 LKA 3GGM 352 810-•RA 1489 95.6 95.5 0.83 0.8 55 6.1 20
315 M3GM 355 LKB 3GGM 352 820-•RA 1490 95.8 95.7 0.83 0.79 70 6.4 27
355 M3GM 355 LKC 3GGM 352 830-•RA 1489 96.0 96.0 0.83 0.8 78 6.4 28
400 M3GM 355 LKD 3GGM 352 840-•RA 1489 96.3 96.2 0.85 0.82 86 6.4 28
450 M3GM 400 LA 3GGM 402 510-•RA 1489 96.7 96.7 0.85 0.83 96 6.1 29
500 M3GM 400 LB 3GGM 402 520-•RA 1490 96.5 96.4 0.85 0.82 107 6.5 35
530 M3GM 400 LC 3GGM 402 530-•RA 1489 96.6 96.5 0.85 0.84 112 6.4 34
1500 r/min = 4 poles 6000 V 50 Hz
250 M3GM 355 LKA 3GGM 352 810-•TA 1486 95.5 95.5 0.83 0.8 30 5.7 11
315 M3GM 355 LKB 3GGM 352 820-•TA 1487 96.0 95.9 0.83 0.79 38 6.4 15
355 M3GM 400 LA 3GGM 402 510-•TA 1489 96.2 96.2 0.85 0.83 42 6.2 13
400 M3GM 400 LB 3GGM 402 520-•TA 1489 96.4 96.4 0.85 0.83 47 6.4 15
450 M3GM 400 LC 3GGM 402 530-•TA 1489 96.2 96.2 0.86 0.84 53 6.2 16
500 M3GM 400 LD 3GGM 402 540-•TA 1490 96.4 96.4 0.85 0.83 59 6.4 18
1500 r/min = 4 poles 6600 V 50 Hz
250 M3GM 355 LKA 3GGM 352 810-•SA 1488 95.5 95.4 0.82 0.78 28 6.1 11
315 M3GM 355 LKB 3GGM 352 820-•SA 1487 95.9 95.9 0.83 0.8 35 6.3 13
355 M3GM 400 LA 3GGM 402 510-•SA 1489 96.2 96.2 0.85 0.83 38 6.1 12
400 M3GM 400 LB 3GGM 402 520-•SA 1489 96.3 96.3 0.85 0.83 43 6.2 13
450 M3GM 400 LC 3GGM 402 530-•SA 1489 96.2 96.2 0.85 0.83 48 6.4 15
500 M3GM 400 LD 3GGM 402 540-•SA 1490 96.4 96.4 0.85 0.83 53 6.5 17
1)
The bullet in the product code indicates choice When ordering, the following variant codes have to be added to the product code acc. to
of mounting arrangement needs. The above prices INCLUDE the extra price acc. to variant code:
(see ordering information page). for non-sparking motors:
456 = Ex nA design, fulfilling IEC 60079-15, with certificate.
480 = EEx nA, fulfilling EN 50021.
for DIP motors:
453 = DIP according to EN 50281-1-1, T= 125°C, category 2D, IP65 (for zone 21)
805 = DIP according to IEC 61241-1-1, T= 125°C, IP65 (for zone 21)
452 = DIP according to EN 50281-1-1, T= 125°C, category 3D, IP55 (for zone 22)
454 = DIP according to EN 50281-1-1, T= 125°C, category 3D, IP65 (for zone 22)
804 = DIP according to IEC 61241-1-1, T= 125°C, IP55 (for zone 22)
806 = DIP according to IEC 61241-1-1, T= 125°C, IP65 (for zone 22)

30 ABB/ BU Machines / HV Induction motors IEC catalogue / Standard motors EN 05-2006


Non-sparking and Dust Ignition Proof HV Cast iron motors
Technical data for totally enclosed squirrel
cage three phase motors
IP 55 – IC 411 – Insulation class F, temperature rise class B
Torque
Load Starting Maximum Sound
TN TS Tmax Power inertia time stalling Rotor Rotor Motor pressure
Output Motor type factor 1)
cold 2) time hot inertia weight weight level LP 3)
kW Nm TN TN cos ϕk kgm2 s s kgm2 kg kg dB(A)

1500 r/min = 4 poles 3000 V 50 Hz


110 M3GM 315 LKA 706 1.6 2.3 0.21 50 9 20 2 220 1190 73
132 M3GM 315 LKB 849 1.3 1.9 0.21 53 10 20 2 220 1190 73
160 M3GM 315 LKC 1029 1.7 2.2 0.21 69 8 16 3.2 260 1190 73
200 M3GM 315 LKD 1287 1.8 2.2 0.21 78 7 14 3.9 300 1290 73
250 M3GM 355 LKA 1603 1.3 2.2 0.17 86 8 16 6.4 400 1860 74
315 M3GM 355 LKB 2021 1.3 2.1 0.17 92 7 14 7.6 450 1990 74
355 M3GM 355 LKC 2278 1.4 2.1 0.17 105 7 14 8.4 480 2090 74
400 M3GM 355 LKD 2566 1.4 2.2 0.17 120 7 14 10.4 550 2310 74
450
500
M3GM
M3GM
400 LA
400 LB
2855
3206
1.5
1.5
2.1
2.1
0.16
0.16
125
134
6
6
12
12
14.4
14.4
660
660
2880
2870
74
79
1
530 M3GM 400 LC 3398 1.5 2.1 0.16 147 6 12 16.2 710 3040 79
1500 r/min = 4 poles 3300 V 50 Hz
132 M3GM 315 LKA 847 1.7 2.3 0.21 70 10 20 2 220 1190 73
160 M3GM 315 LKB 1029 1.5 2.0 0.21 70 10 20 2.3 240 1260 73
200 M3GM 315 LKC 1287 1.8 2.2 0.21 78 7 14 3.9 300 1290 73
250 M3GM 355 LKA 1603 1.3 2.2 0.17 83 8 16 6.4 400 1860 74
315 M3GM 355 LKB 2019 1.5 2.3 0.17 87 6 12 7.6 450 1970 74
355 M3GM 355 LKC 2277 1.5 2.2 0.17 98 6 12 8.4 480 2070 74
400 M3GM 355 LKD 2565 1.5 2.2 0.17 107 6 12 10.4 550 2300 74
450 M3GM 400 LA 2886 1.4 2.0 0.16 114 6 12 13.2 620 2760 74
500 M3GM 400 LB 3025 1.5 2.1 0.16 140 6 10 14.4 660 2850 79
530 M3GM 400 LC 3398 1.5 2.1 0.16 143 6 11 16.8 730 3100 79
1500 r/min = 4 poles 6000 V 50 Hz
250 M3GM 355 LKA 1606 1.2 2.1 0.17 95 9 20 4.6 380 2010 74
315 M3GM 355 LKB 2022 1.5 2.3 0.17 110 7 18 5.9 440 2290 74
355 M3GM 400 LA 2277 1.4 2.1 0.17 110 7 14 12 600 2590 74
400 M3GM 400 LB 2565 1.5 2.1 0.17 111 6 12 13.2 640 2720 74
450 M3GM 400 LC 2887 1.5 2.1 0.17 122 6 12 14.4 670 2840 79
500 M3GM 400 LD 3206 1.6 2.1 0.17 138 6 12 15.6 700 2950 79
1500 r/min = 4 poles 6600 V 50 Hz
250 M3GM 355 LKA 1605 1.4 2.3 0.17 93 8 16 4.6 380 2010 74
315 M3GM 355 LKB 2023 1.4 2.3 0.17 105 7 14 5.9 440 2280 74
355 M3GM 400 LA 2277 1.4 2.1 0.17 110 7 14 12 600 2600 74
400 M3GM 400 LB 2566 1.5 2.1 0.17 125 7 14 13.2 640 2710 74
450 M3GM 400 LC 2886 1.6 2.1 0.17 128 6 12 14.4 670 2830 79
500 M3GM 400 LD 3205 1.6 2.1 0.17 141 6 12 15.6 700 2940 79
1)
The given values of load inertia assume three starts from cold and 3)
The sound pressure levels are presented at no-load. The
two starts from warm conditions in successions against quadratic magnetic noise level of 2- and 4-pole motors is typically low
load torque with 90% of the rated torque at the rated speed and compared to the fan noise, resulting no increase in the noise
at 80% of the rated voltage. level on-load. The variation and measuring tolerance of the figures
2)
is + 3 dB(A).
Starting time with given values of the load inertia from cold
condition in succession against quadratic load torque with 90%
of the rated torque at the rated speed and at rated voltage.

ABB/ BU Machines / HV Induction motors IEC catalogue / Standard motors EN 05-2006 31


Non-sparking and Dust Ignition Proof HV Cast iron motors
Technical data for totally enclosed squirrel
cage three phase motors
IP 55 – IC 411 – Insulation class F, temperature rise class B
Efficiency Power factor Current
Full 3/4 Full 3/4 IN IS I0
Output Motor type Product code Speed load load load load
kW r/min 100% 75% 100% 75% A IN A

1000 r/min = 6 poles 3000 V 50 Hz


110 M3GM 315 LKA 3GGM 313 810-•QA 987 94.4 94.6 0.79 0.76 28 5.3 12
132 M3GM 315 LKB 3GGM 313 820-•QA 986 94.7 94.9 0.79 0.75 34 5.4 14
150 M3GM 315 LKC 3GGM 313 830-•QA 987 95.1 95.2 0.8 0.75 38 5.7 16
160 M3GM 355 LKA 3GGM 353 810-•QA 992 95.3 95.2 0.74 0.68 43 5.5 22
200 M3GM 355 LKB 3GGM 353 820-•QA 990 95.7 95.7 0.78 0.74 52 5.3 22
250 M3GM 355 LKC 3GGM 353 830-•QA 991 96.0 96.0 0.78 0.74 64 5.5 28
315 M3GM 400 L 3GGM 403 500-•QA 991 96.1 96.2 0.81 0.78 78 5.9 29
355 M3GM 400 LA 3GGM 403 510-•QA 991 96.3 96.4 0.82 0.79 87 5.9 31

1 400
425
M3GM
M3GM
400 LB
400 LC
3GGM
3GGM
403 520-•QA
403 530-•QA
991
991
96.4
96.4
96.5
96.5
0.82
0.82
0.79
0.79
98
104
6.2
6.3
36
38
1000 r/min = 6 poles 3300 V 50 Hz
110 M3GM 315 LKA 3GGM 313 810-•RA 988 94.5 94.6 0.79 0.74 26 5.6 11
132 M3GM 315 LKB 3GGM 313 820-•RA 987 94.7 94.9 0.79 0.75 31 5.6 13
150 M3GM 315 LKC 3GGM 313 830-•RA 987 95.1 95.2 0.8 0.75 35 5.7 15
160 M3GM 355 LKA 3GGM 353 810-•RA 992 95.3 95.1 0.73 0.67 40 5.7 21
200 M3GM 355 LKB 3GGM 353 820-•RA 990 95.6 95.7 0.78 0.74 47 5.3 20
250 M3GM 355 LKC 3GGM 353 830-•RA 990 95.9 96.0 0.79 0.75 58 5.3 24
315 M3GM 400 L 3GGM 403 500-•RA 990 96 96.2 0.81 0.79 71 5.7 25
355 M3GM 400 LA 3GGM 403 510-•RA 991 96.2 96.3 0.81 0.79 79 6.0 29
400 M3GM 400 LB 3GGM 403 520-•RA 991 96.4 96.5 0.82 0.79 89 6.0 32
425 M3GM 400 LC 3GGM 403 530-•RA 991 96.5 96.6 0.82 0.78 95 6.4 35
1000 r/min = 6 poles 6000 V 50 Hz
220 M3GM 355 LKA 3GGM 353 810-•TA 992 95.5 95.5 0.79 0.74 28 6.3 12
250 M3GM 355 LKB 3GGM 353 820-•TA 991 95.6 95.7 0.8 0.76 31 6 13
280 M3GM 400 L 3GGM 403 500-•TA 991 96 96 0.79 0.75 36 5.6 15
315 M3GM 400 LA 3GGM 403 510-•TA 992 96.2 96.1 0.79 0.75 40 5.8 17
355 M3GM 400 LB 3GGM 403 520-•TA 991 96.3 96.3 0.8 0.76 45 5.6 18
375 M3GM 400 LC 3GGM 403 530-•TA 991 96.3 96.3 0.79 0.76 47 5.8 19
1000 r/min = 6 poles 6600 V 50 Hz
250 M3GM 355 LKA 3GGM 353 810-•SA 992 95.6 95.6 0.79 0.75 29 6.3 13
280 M3GM 400 L 3GGM 403 500-•SA 991 95.9 95.9 0.78 0.74 33 5.6 14
315 M3GM 400 LA 3GGM 403 510-•SA 992 96.2 96.1 0.78 0.73 37 6.1 16
355 M3GM 400 LB 3GGM 403 520-•SA 991 96.3 96.3 0.79 0.75 41 5.8 17
375 M3GM 400 LC 3GGM 403 530-•SA 992 96.4 96.3 0.79 0.75 43 5.9 18

The bullet in the product code indicates choice 1)


When ordering, the following variant codes have to be added to the product code acc. to
of mounting arrangement needs. The above prices INCLUDE the extra price acc. to variant code:
(see ordering information page).
for non-sparking motors:
456 = Ex nA design, fulfilling IEC 60079-15, with certificate.
480 = EEx nA, fulfilling EN 50021.
for DIP motors:
453 = DIP according to EN 50281-1-1, T= 125°C, category 2D, IP65 (for zone 21)
805 = DIP according to IEC 61241-1-1, T= 125°C, IP65 (for zone 21)
452 = DIP according to EN 50281-1-1, T= 125°C, category 3D, IP55 (for zone 22)
454 = DIP according to EN 50281-1-1, T= 125°C, category 3D, IP65 (for zone 22)
804 = DIP according to IEC 61241-1-1, T= 125°C, IP55 (for zone 22)
806 = DIP according to IEC 61241-1-1, T= 125°C, IP65 (for zone 22)

32 ABB/ BU Machines / HV Induction motors IEC catalogue / Standard motors EN 05-2006


Non-sparking and Dust Ignition Proof HV Cast iron motors
Technical data for totally enclosed squirrel
cage three phase motors
IP 55 – IC 411 – Insulation class F, temperature rise class B
Torque
Load Starting Maximum Sound
TN TS Tmax Power inertia time stalling Rotor Rotor Motor pressure
Output Motor type factor 1)
cold 2) time hot inertia weight weight level LP 3)
kW Nm TN TN cos ϕk kgm2 s s kgm2 kg kg dB(A)

1000 r/min = 6 poles 3000 V 50 Hz


110 M3GM 315 LKA 1065 1.5 2.0 0.22 127 10 20 3.2 270 1170 65
132 M3GM 315 LKB 1278 1.6 2.1 0.22 144 9 18 3.7 290 1240 65
150 M3GM 315 LKC 1452 1.7 2.2 0.22 156 8 20 4.6 340 1380 65
160 M3GM 355 LKA 1541 1.5 2.1 0.19 178 10 20 4.8 350 1660 70
200 M3GM 355 LKB 1928 1.4 2.0 0.19 205 10 20 6.4 410 1850 70
250 M3GM 355 LKC 2410 1.5 2.0 0.19 275 10 20 8 480 2040 70
315 M3GM 400 L 3036 1.6 2.0 0.18 335 9 18 16.2 680 2500 75
355 M3GM 400 LA 3422 1.6 2.0 0.18 370 9 18 19.8 770 2740 75
400
425
M3GM
M3GM
400 LB
400 LC
3854
4094
1.7
1.8
2.0
2.1
0.19
0.19
400
435
8
8
18
18
23.4
26.1
870
940
2970
3130
75
75
1
1000 r/min = 6 poles 3300 V 50 Hz
110 M3GM 315 LKA 1064 1.6 2.1 0.22 136 10 20 3.2 270 1170 65
132 M3GM 315 LKB 1277 1.7 2.1 0.22 149 9 18 3.7 290 1240 65
150 M3GM 315 LKC 1452 1.7 2.2 0.22 175 9 20 4.6 340 1380 65
160 M3GM 355 LKA 1540 1.5 2.2 0.19 184 10 20 4.8 350 1660 70
200 M3GM 355 LKB 1928 1.4 2.0 0.19 204 10 20 6.4 410 1850 70
250 M3GM 355 LKC 2412 1.4 1.9 0.19 258 10 20 8 480 2040 70
315 M3GM 400 L 3038 1.5 1.9 0.18 350 9 18 16.2 680 2500 75
355 M3GM 400 LA 3422 1.6 2.0 0.19 382 9 18 19.8 770 2730 75
400 M3GM 400 LB 3855 1.7 2.0 0.19 435 9 18 23.4 870 2970 75
425 M3GM 400 LC 4094 1.8 2.1 0.19 445 8 18 26.1 940 3140 75
1000 r/min = 6 poles 6000 V 50 Hz
220 M3GM 355 LKA 2118 1.8 2.3 0.21 198 7 14 9.6 540 2160 70
250 M3GM 355 LKB 2409 1.7 2.1 0.21 210 7 14 10.4 570 2250 70
280 M3GM 400 L 2697 1.3 2.0 0.17 290 10 20 11.4 590 2530 75
315 M3GM 400 LA 3033 1.4 2.1 0.17 342 10 20 13.2 640 2700 75
355 M3GM 400 LB 3421 1.4 2.0 0.17 367 10 20 14.4 680 2820 75
375 M3GM 400 LC 3613 1.4 2.0 0.17 410 10 20 15.6 720 2940 75
1000 r/min = 6 poles 6600 V 50 Hz
250 M3GM 355 LKA 2408 1.8 2.2 0.21 193 6 12 10.4 570 2250 70
280 M3GM 400 L 2697 1.3 2.0 0.17 290 10 20 10.8 570 2460 75
315 M3GM 400 LA 3032 1.5 2.2 0.17 369 10 20 13.2 640 2700 75
355 M3GM 400 LB 3419 1.4 2.0 0.17 390 10 20 14.4 680 2820 75
375 M3GM 400 LC 3611 1.5 2.1 0.17 427 10 20 15.6 720 2940 75
1) 3)
The given values of load inertia assume three starts from cold and The sound pressure levels are presented at no-load. Sound level
two starts from warm conditions in successions against quadratic values of 6...12-pole motors at no-load are typically 1...3 dB(A)
load torque with 90% of the rated torque at the rated speed and higher than the corresponding values at no-load. The variation and
at 80% of the rated voltage. measuring tolerance of the figures is +3 dB(A).
2)
Starting time with given values of the load inertia from cold
condition in succession against quadratic load torque with 90%
of the rated torque at the rated speed and at rated voltage.

ABB/ BU Machines / HV Induction motors IEC catalogue / Standard motors EN 05-2006 33


Non-sparking and Dust Ignition Proof HV Cast iron motors
Technical data for totally enclosed squirrel
cage three phase motors
IP 55 – IC 411 – Insulation class F, temperature rise class B
Efficiency Power factor Current
Full 3/4 Full 3/4 IN IS I0
Output Motor type Product code Speed load load load load
kW r/min 100% 75% 100% 75% A IN A

750 r/min = 8 poles 3000 V 50 Hz


200 M3GM 400 LA 3GGM 404 510-•QA 742 95.1 95.2 0.79 0.76 51 5.3 21
220 M3GM 400 LB 3GGM 404 520-•QA 742 95.3 95.4 0.79 0.75 56 5.5 24
250 M3GM 400 LC 3GGM 404 530-•QA 742 95.4 95.6 0.8 0.76 63 5.4 25
280 M3GM 400 LD 3GGM 404 540-•QA 741 95.4 95.6 0.8 0.77 70 5.2 26
300 M3GM 400 LE 3GGM 404 540-•QA 741 95.6 95.8 0.8 0.77 75 5.4 29
750 r/min = 8 poles 3300 V 50 Hz
200 M3GM 400 LA 3GGM 404 510-•RA 742 95 95.2 0.79 0.76 46 5.2 19
220 M3GM 400 LB 3GGM 404 520-•RA 742 95.2 95.4 0.8 0.76 51 5.3 20

1 250
280
M3GM
M3GM
400 LC
400 LD
3GGM
3GGM
404 530-•RA
404 540-•RA
741
741
95.3
95.5
95.6
95.7
0.8
0.8
0.78
0.77
57
64
5.0
5.5
21
25
300 M3GM 400 LE 3GGM 404 550-•RA 741 95.5 95.7 0.8 0.77 69 5.5 27
750 r/min = 8 poles 6000 V 50 Hz
160 M3GM 400 LA 3GGM 404 510-•TA 741 94.4 94.4 0.76 0.71 21 5.2 10
180 M3GM 400 LB 3GGM 404 520-•TA 740 94.5 94.6 0.77 0.72 24 5.0 11
200 M3GM 400 LC 3GGM 404 530-•TA 740 94.7 94.8 0.77 0.73 26 5.1 12
220 M3GM 400 LD 3GGM 404 540-•TA 740 94.8 95.0 0.78 0.74 29 5.0 12
250 M3GM 400 LE 3GGM 404 550-•TA 740 95.1 95.1 0.77 0.72 33 5.3 15
750 r/min = 8 poles 6600 V 50 Hz
160 M3GM 400 LA 3GGM 404 510-•SA 741 94.5 94.4 0.76 0.71 20 5.4 9
180 M3GM 400 LB 3GGM 404 520-•SA 741 94.5 94.5 0.76 0.7 22 5.3 11
200 M3GM 400 LC 3GGM 404 530-•SA 740 94.6 94.8 0.78 0.74 24 4.8 10
220 M3GM 400 LD 3GGM 404 540-•SA 740 94.9 94.9 0.77 0.72 26 5.2 12
250 M3GM 400 LE 3GGM 404 550-•SA 741 95.1 95.1 0.76 0.71 30 5.5 14
The bullet in the product code indicates choice of mounting
arrangement (see ordering information page).

1)
When ordering, the following variant codes have to be added to the product code acc. to
needs. The above prices INCLUDE the extra price acc. to variant code:
for non-sparking motors:
456 = Ex nA design, fulfilling IEC 60079-15, with certificate.
480 = EEx nA, fulfilling EN 50021.
for DIP motors:
453 = DIP according to EN 50281-1-1, T= 125°C, category 2D, IP65 (for zone 21)
805 = DIP according to IEC 61241-1-1, T= 125°C, IP65 (for zone 21)
452 = DIP according to EN 50281-1-1, T= 125°C, category 3D, IP55 (for zone 22)
454 = DIP according to EN 50281-1-1, T= 125°C, category 3D, IP65 (for zone 22)
804 = DIP according to IEC 61241-1-1, T= 125°C, IP55 (for zone 22)
806 = DIP according to IEC 61241-1-1, T= 125°C, IP65 (for zone 22)

34 ABB/ BU Machines / HV Induction motors IEC catalogue / Standard motors EN 05-2006


Non-sparking and Dust Ignition Proof HV Cast iron motors
Technical data for totally enclosed squirrel
cage three phase motors
IP 55 – IC 411 – Insulation class F, temperature rise class B
Torque
Load Starting Maximum Sound
TN TS Tmax Power inertia time stalling Rotor Rotor Motor pressure
Output Motor type factor 1)
cold 2) time hot inertia weight weight level LP 3)
kW Nm TN TN cos ϕk kgm2 s s kgm2 kg kg dB(A)

750 r/min = 8 poles 3000 V 50 Hz


200 M3GM 400 LA 2575 1.0 2.1 0.15 390 11 22 14.4 630 2370 75
220 M3GM 400 LB 2831 1.1 2.3 0.14 425 10 20 16.2 680 2490 75
250 M3GM 400 LC 3219 1.1 2.2 0.14 480 10 20 19.8 780 2730 75
280 M3GM 400 LD 3610 1.1 2.1 0.14 530 10 20 21.6 830 2830 75
300 M3GM 400 LE 3866 1.1 2.1 0.14 565 10 20 23.4 870 2960 75
750 r/min = 8 poles 3300 V 50 Hz
200 M3GM 400 LA 2575 1.0 2.1 0.15 390 11 22 14.4 630 2370 75
220 M3GM 400 LB 2833 1.1 2.1 0.14 425 10 20 16.2 680 2490 75
250
280
M3GM
M3GM
400 LC
400 LD
3223
3607
1.0
1.1
2.0
2.2
0.14
0.14
480
530
11
9
22
18
19.8
21.6
780
830
2720
2840
75
75
1
300 M3GM 400 LE 3865 1.1 2.2 0.14 565 9 18 23.4 870 2940 75
750 r/min = 8 poles 6000 V 50 Hz
160 M3GM 400 LA 2062 1.1 2.2 0.16 320 10 20 10.2 560 2380 75
180 M3GM 400 LB 2322 1.0 2.1 0.16 355 11 22 10.8 580 2450 75
200 M3GM 400 LC 2580 1.1 2.2 0.15 390 10 20 12.6 640 2620 75
220 M3GM 400 LD 2840 1.0 2.1 0.15 425 10 20 13.8 680 2740 75
250 M3GM 400 LE 3225 1.2 2.3 0.15 480 9 18 15.6 740 2920 75
750 r/min = 8 poles 6600 V 50 Hz
160 M3GM 400 LA 2061 1.1 2.3 0.16 320 10 20 10.8 580 2440 75
180 M3GM 400 LB 2319 1.1 2.3 0.16 355 10 20 10.8 580 2440 75
200 M3GM 400 LC 2583 1.0 2.0 0.16 390 11 22 12.6 640 2620 75
220 M3GM 400 LD 2838 1.1 2.2 0.15 425 10 20 13.8 680 2740 75
250 M3GM 400 LE 3223 1.2 2.3 0.15 480 9 18 15.6 740 2910 75
1) 3)
The given values of load inertia assume three starts from cold and The sound pressure levels are presented at no-load. Sound level
two starts from warm conditions in successions against quadratic values of 6...12-pole motors at no-load are typically 1...3 dB(A)
load torque with 90% of the rated torque at the rated speed and higher than the corresponding values at no-load. The variation and
at 80% of the rated voltage. measuring tolerance of the figures is +3 dB(A).
2)
Starting time with given values of the load inertia from cold
condition in succession against quadratic load torque with 90%
of the rated torque at the rated speed and at rated voltage.

ABB/ BU Machines / HV Induction motors IEC catalogue / Standard motors EN 05-2006 35


Non-sparking and Dust Ignition Proof HV Cast iron motors
Technical data for totally enclosed squirrel
cage three phase motors
IP 55 – IC 411 – Insulation class F, temperature rise class B
Efficiency Power factor Current
Full 3/4 Full 3/4 IN IS I0
Output Motor type Product code Speed load load load load
kW r/min 100% 75% 100% 75% A IN A

600 r/min = 10 poles 3000 V 50 Hz


150 M3GM 400 LA 3GGM 405 510-•QA 593 94.1 93.9 0.72 0.67 43 4.7 22
160 M3GM 400 LB 3GGM 405 520-•QA 594 94.2 93.9 0.71 0.65 46 4.9 25
180 M3GM 400 LC 3GGM 405 530-•QA 593 94.3 94.0 0.71 0.65 51 4.9 27
200 M3GM 400 LD 3GGM 405 540-•QA 593 94.5 94.2 0.72 0.66 57 4.9 29
220 M3GM 400 LE 3GGM 405 550-•QA 593 94.6 94.2 0.71 0.64 63 5.2 35
600 r/min = 10 poles 3300 V 50 Hz
150 M3GM 400 LA 3GGM 405 510-•RA 593 94.1 93.8 0.71 0.66 39 4.8 20
160 M3GM 400 LB 3GGM 405 520-•RA 594 94.2 93.8 0.71 0.64 42 5.0 23

1 180
200
M3GM
M3GM
400 LC
400 LD
3GGM
3GGM
405 530-•RA
405 540-•RA
593
593
94.3
94.4
94.0
94.2
0.71
0.72
0.65
0.67
47
51
4.9
4.8
25
26
220 M3GM 400 LE 3GGM 405 550-•RA 593 94.5 94.3 0.72 0.66 57 5.0 30
500 r/min = 12 poles 3000 V 50 Hz
110 M3GM 400 LA 3GGM 406 510-•QA 494 93.1 92.8 0.66 0.6 34 4.3 19
120 M3GM 400 LB 3GGM 406 520-•QA 494 93.2 93.0 0.67 0.61 37 4.3 21
132 M3GM 400 LC 3GGM 406 530-•QA 494 93.4 93.1 0.67 0.61 41 4.3 23
150 M3GM 400 LD 3GGM 406 540-•QA 494 93.5 93.2 0.66 0.61 46 4.3 26
160 M3GM 400 LE 3GGM 406 550-•QA 494 93.7 93.2 0.66 0.59 50 4.6 29
500 r/min = 12 poles 3300 V 50 Hz
110 M3GM 400 LA 3GGM 406 510-•RA 494 93.1 92.7 0.66 0.6 31 4.4 18
120 M3GM 400 LB 3GGM 406 520-•RA 494 93.2 92.9 0.66 0.6 34 4.3 19
132 M3GM 400 LC 3GGM 406 530-•RA 494 93.4 93.1 0.67 0.61 37 4.3 21
150 M3GM 400 LD 3GGM 406 540-•RA 493 93.5 93.3 0.67 0.61 42 4.3 23
160 M3GM 400 LE 3GGM 406 550-•RA 494 93.7 93.3 0.66 0.6 45 4.4 25

The bullet in the product code indicates choice of mounting


arrangement (see ordering information page).

1)
When ordering, the following variant codes have to be added to the product code acc. to
needs. The above prices INCLUDE the extra price acc. to variant code:
for non-sparking motors:
456 = Ex nA design, fulfilling IEC 60079-15, with certificate.
480 = EEx nA, fulfilling EN 50021.
for DIP motors:
453 = DIP according to EN 50281-1-1, T= 125°C, category 2D, IP65 (for zone 21)
805 = DIP according to IEC 61241-1-1, T= 125°C, IP65 (for zone 21)
452 = DIP according to EN 50281-1-1, T= 125°C, category 3D, IP55 (for zone 22)
454 = DIP according to EN 50281-1-1, T= 125°C, category 3D, IP65 (for zone 22)
804 = DIP according to IEC 61241-1-1, T= 125°C, IP55 (for zone 22)
806 = DIP according to IEC 61241-1-1, T= 125°C, IP65 (for zone 22)

36 ABB/ BU Machines / HV Induction motors IEC catalogue / Standard motors EN 05-2006


Non-sparking and Dust Ignition Proof HV Cast iron motors
Technical data for totally enclosed squirrel
cage three phase motors
IP 55 – IC 411 – Insulation class F, temperature rise class B
Torque
Load Starting Maximum Sound
TN TS Tmax Power inertia time stalling Rotor Rotor Motor pressure
Output Motor type factor 1)
cold 2) time hot inertia weight weight level LP 3)
kW Nm TN TN cos ϕk kgm2 s s kgm2 kg kg dB(A)

600 r/min = 10 poles 3000 V 50 Hz


150 M3GM 400 LA 2415 1 2 0.15 515 13 26 16.2 680 2480 75
160 M3GM 400 LB 2574 1.1 2.1 0.15 545 12 24 17.1 710 2540 75
180 M3GM 400 LC 2897 1.1 2.1 0.15 605 11 22 18.9 750 2660 75
200 M3GM 400 LD 3220 1.1 2.1 0.14 670 11 22 21.6 830 2840 75
220 M3GM 400 LE 3540 1.2 2.2 0.14 730 10 20 23.4 880 2950 75
600 r/min = 10 poles 3300 V 50 Hz
150 M3GM 400 LA 2414 1.0 2.0 0.15 515 12 24 16.2 680 2470 75
160 M3GM 400 LB 2573 1.1 2.2 0.15 545 11 22 17.1 710 2530 75
180
200
M3GM
M3GM
400 LC
400 LD
2897
3222
1.1
1.0
2.1
2.0
0.15
0.14
605
670
11
12
22
24
18.9
21.6
750
830
2650
2830
75
75
1
220 M3GM 400 LE 3542 1.1 2.1 0.14 730 11 22 23.4 880 2950 75
500 r/min = 12 poles 3000 V 50 Hz
110 M3GM 400 LA 2126 1.0 2.0 0.14 595 14 28 16.2 680 2470 75
120 M3GM 400 LB 2320 1.0 2.0 0.14 650 14 28 18 730 2580 75
132 M3GM 400 LC 2553 1.0 2.0 0.14 710 14 28 19.8 780 2700 75
150 M3GM 400 LD 2902 1.1 2.0 0.14 795 13 26 21.6 830 2820 75
160 M3GM 400 LE 3092 1.1 2.1 0.14 845 12 24 24.3 900 3000 75
500 r/min = 12 poles 3300 V 50 Hz
110 M3GM 400 LA 2125 1.1 2.1 0.14 595 13 26 16.2 680 2460 75
120 M3GM 400 LB 2320 1.0 2.0 0.14 650 14 28 18 730 2580 75
132 M3GM 400 LC 2553 1.0 2.0 0.14 710 14 28 19.8 780 2700 75
150 M3GM 400 LD 2903 1.0 1.9 0.14 795 14 28 21.6 830 2820 75
160 M3GM 400 LE 3094 1.1 2.0 0.14 845 13 26 24.3 900 3000 75
1) 3)
The given values of load inertia assume three starts from cold and The sound pressure levels are presented at no-load. Sound level
two starts from warm conditions in successions against quadratic values of 6...12-pole motors at no-load are typically 1...3 dB(A)
load torque with 90% of the rated torque at the rated speed and higher than the corresponding values at no-load. The variation and
at 80% of the rated voltage. measuring tolerance of the figures is +3 dB(A).
2)
Starting time with given values of the load inertia from cold
condition in succession against quadratic load torque with 90%
of the rated torque at the rated speed and at rated voltage.

ABB/ BU Machines / HV Induction motors IEC catalogue / Standard motors EN 05-2006 37


HV Process performance cast iron motors - Variant codes
Code Variant Motor size
1)
315 355 400
Balancing
423 Balanced without key P P P
424 Full key balancing. P P P
Bearings and lubrication
036 Transport lock for bearings. P P P
037 Roller bearing at D-end. P P P
107 Bearing mounted PT100 resistance elements. P P P
796 Grease nipples JIS B 1575 PT 1/8 Type A. P P P
Branch standard designs
178 Stainless steel/acid proof bolts. P P P
398 Motor designed for ambient temperature -20°C to -40°C. P P P
Cooling system
44 Unidirectional fan, clockwise seen from D-end. NA NA P
45 Unidirectional fan, counter clockwise seen from D-end. NA NA P
68 Metal fan (for M3BM motors only). P P P

1 791

65
Stainless steel fan cover (horizontal motor only).
Drain holes
Plugged existing drain holes.
R

P
R

P
R

P
448 Draining holes with metal plugs. P P P
Heating elements
450 Heating element, 100-120 V. P P P
451 Heating element, 200-240 V. P P P
Painting
114 Special paint colour, standard grade. P P P
751 Paint system 2, UV-light. P P P
Surface treatment acc. to the ISO 12944, category 3 with direct UV radiation.
752 Paint system 4, offshore. P P P
Surface treatment acc. to the ISO 12944, category C5 & Norsok M-501.
Protection
005 Protective roof, vertical motor, shaft down. P P P
401 Protective roof, horizontal motor (for M3BM motors only). R R R
158 Degree of protection IP 65. P P P
403 Degree of protection IP 56. P P P
Rating & instruction plates
002 Restamping output and voltage, continuous duty. For M3GM on request. P P P
Standards and regulations
010 Fulfilling CSA Safety Certificate. P P P
778 GOST Export/Import Certificate (Russia). P P P
782 Fulfilling CQST Certificate requirements (China) (for M3GM motors only). R R R
Terminal box
021 Terminal box LHS (seen from D-end). P P P
447 Top mounted separate auxiliary box for heating elements (for M3BM motors only). P P P
750 Star point terminal box. P P P
Testing
Routine test report included as standard.
146 Type test with report for motor from specific delivery patch. P P P
147 Type test with report for motor from specific delivery patch, customer witnessed. P P P
Variable speed drives
701 Insulated bearing at N-end. P P P

1)
Certain variant codes cannot be used simultaneously. P = New manufacture only. R = On request.
NA = Not applicable.

38 ABB/ BU Machines / HV Induction motors IEC catalogue / Standard motors EN 05-2006


HV Process performance cast iron motors Sizes 315-400
Dimension drawings
Foot-mounted: IM B3 (IM 1001)

Motor Poles A AA AB AC AD B B' B'' BA BB C D DB E EG


size

315 LK 2 508 100 590 656 555 508 560 710 336 851 216 65 M20 140 42
315 LK 4-6 508 100 590 656 555 508 560 710 336 851 216 90 M24 170 52
355 LK 2 610 120 700 746 627 630 710 900 447 1077 254 70 M20 140 42
355 LK 4-6 610 120 700 746 627 630 710 900 447 1077 254 100 M24 210 51
400 L 2 710 150 840 834 627 900 1000 - 410 1156 224 80 M20 170 42
400 L 4-12 710 150 840 834 627 900 1000 - 410 1156 224 110 M24 210 50

Motor Poles F G GA GD H HA HC HD K L LD O
size

315 LK 2 18 58 69 11 315 40 643 1055 28 1490 355 115


315 LK 4-6 25 81 95 14 315 40 643 1055 28 1521 385 115
355 LK 2 20 62.5 74.5 12 355 52 725 1138 35 1764 398 130
355 LK 4-6 28 90 106 16 355 52 725 1138 35 1834 468 130
400 L 2 22 71 85 14 400 45 814 1225 35 1851 458 150
400 L 4-12 28 100 116 16 400 45 814 1225 35 1891 498 150

Tolerances:
A, B, C ± 0,8 F ISO h9 The above table gives the main dimensions in mm.
D ISO m6 H +0 -1.0
For detailed drawings please see our web-pages 'www.
abb.com/motors&drives' or contact us.

ABB/ BU Machines / HV Induction motors IEC catalogue / Standard motors EN 05-2006 39


HV Process performance cast iron motors Sizes 315-400
Dimension drawings
Flange-mounted; IM V1 (IM 3011)

Motor Poles AC D DB E EG F G GA GD HB
size

315 LK 4-6 725 100 M24 210 51 28 90 106 16 731


355 LK 4-6 725 100 M24 210 51 28 90 106 16 774
400 L 4-12 814 110 M24 210 50 28 100 106 16 816

Motor Poles L LA LB LD M N O P S T
size

315 LK 4-6 1834 25 1624 1116 600 550 130 800 23 6


355 LK 4-6 1834 25 1624 1386 740 680 130 800 23 6
400 L 4-12 1891 26 1681 1400 940 880 150 1000 28 6

Tolerances:
D ISO m6 N ISO js6 (315_)
F ISO h9

The above table gives the main dimensions in mm.


For detailed drawings please see our web-pages 'www.
abb.com/motors&drives' or contact us.

40 ABB/ BU Machines / HV Induction motors IEC catalogue / Standard motors EN 05-2006


Accessories
Foundation studs Slide rails

Frame size Set code Frame size Set code


315 FOST315-M3 315 SLRA315-M3
355 FOST355-M3 355 SLRA355-M3
400 FOST400-M3 400 SLRA400-M3
The set code has to be mentioned on order. The set code has to be mentioned on order. 1
Sole plates Sole plates

With anchor bolts for concrete foundation Without anchor bolts


Frame size Set code Frame size Set code
315 SOPL315A-M3 315 SOPL315-M3
355 SOPL355A-M3 355 SOPL355-M3
400 SOPL400A-M3 400 SOPL400-M3
The set code has to be mentioned on order. The set code has to be mentioned on order.

Protective roof
Variant code 005

Motor Pole L LL
size number
LL

315 LK 4-6 1591 1421


L

355 LK 4-6 1951 1741


400 L 4-6 2008 1798

ABB/ BU Machines / HV Induction motors IEC catalogue / Standard motors EN 05-2006 41


HV Process performance cast iron motor construction

Typical exploded view of high voltage cast iron motor

1 Stator frame 17 Valve disc with labyrinth seal, D-end


2 End shield, D-end 18 Bearing, N-end
3 Screws for end shield, D-end 19 Inner bearing cover, N-end
4 End shield, N-end 20 Spring
5 Screws for end shield, N-end 21 Screws for bearing cover, N-end
6 Rotor with shaft 22 Fan
7 Key, D-end 23 Fan cover
8 Main terminal box 24 Screws for fan cover
9 Middle box 25 Rating plate
10 Screws for terminal box cover 26 Lubrication plate
11 Outer bearing cover, D-end 27 Auxiliary terminal box
12 Valve disc with labyrinth seal, D-end 28 Grease nipple, D-end
13 Bearing, D-end 29 Grease nipple, N-end
14 Inner bearing cover 30 SPM nipple, D-end
15 Screws for bearing cover, D-end 31 SPM nipple, N-end
16 Outer bearing cover, N-end

42 ABB/ BU Machines / HV Induction motors IEC catalogue / Standard motors EN 05-2006


HV Process performance cast iron motors in brief, basic design
Motor size 315 355 400
Stator Material Cast iron EN-GJL-250 EN 1561
Paint colour shade Blue, Munsell 8B 4.5/3.25 / NCS 4822 B05G / RAL 5014
Paint thickness Two-pack epoxy paint, thickness ≥ 180 µm
Bearing end shields Material Cast iron EN-GJL-200 SFS-EN 1561
Paint colour shade Blue, Munsell 8B 4.5/3.25 / NCS 4822 B05G / RAL 5014
Paint thickness Two-pack epoxy paint, thickness ≥ 180 µm
Bearings D-end 2 pole 6316-M/C3 6316-M/C3 6317-M/C3
4-12 pole 6319/C3 6322/C3 6324/C3
N-end 2 pole 6316-M/C3 6316-M/C3 6317-M/C3
4-12 pole 6316/C3 6316/C3 6319/C3
Axially-locked Inner bearing cover As standard, locked at D-end
bearings
Bearing seal As standard, labyrinth seal in both ends.
Lubrication Regreasable bearings

SPM-nipples
Regreasing nipples M10x1 DIN 71412 A
As standard
1
Rating and Material Stainless steel, EN 10088, thickness 0.5 mm.
lubrication plate
Terminal box Frame material Structural steel S235JRG2-EN-10025, thickness 3 mm.
Cover material Structural steel S235JRG2-EN-10025, thickness 3 mm.
Cover screws material Yellow passivated.
Connections Cable entries Blind gland plate.
Terminals 3 terminals for connection with cable lugs (not included)
Grounding locations on frame and terminal box (in- and outside)
Fan Material Glass fibre reinforced plastic, aluminum or polyprophene fan with metal hub.
Direction of rotation / fans (IC411)
- plastic bidirectional
- aluminum birectional
- polyprophene fan unidirectional.
Fan cover Material Steel
Paint colour shade Blue, Munsell 8B 4.5/3.25 / NCS 4822 B05G / RAL 5014
Paint thickness Two-pack epoxy polyester powder, thickness ≥ 80 µm
Stator winding Material Form wound copper, VPI
Insulation Insulation class F
Winding protection PT100, 6 pieces
Rotor winding Material Pressure die-cast aluminum
Balancing method Half key balancing as standard
Key ways Open key way
Heating elements On request 1x200 W 1x200 W 1x300 W
Drain holes Standard, open on delivery.
Enclosure IP 55, higher protection as option.
Cooling method IC 411

ABB/ BU Machines / HV Induction motors IEC catalogue / Standard motors EN 05-2006 43


1

44 ABB/ BU Machines / HV Induction motors IEC catalogue / Standard motors EN 05-2006


Engineered Motors
Squirrel cage three phase high voltage motors,
Up to 2800 kW

General information ...........................47


Mechanical design .............................49
Notes .................................................63
Technical data....................................64
Dimension drawings ........................100

ABB/ BU Machines / HV Induction motors IEC catalogue / Engineered motors EN 05-2006 45


Contents Page
General Information 47
Enclosure and Cooling 49
Type designation 51
High voltage terminal box for IEC motors 52
Auxiliary boxes 56
Bearings 57
Vibrations 62
Notes 63
Technical Data 64
Technical Data, Cast iron motors, HXR 64
Technical Data, Modular motors 76
Dimension Drawings, Engineered motors, HXR, IC411 100
Dimension Drawings, Engineered motors, AMA, IC01 106
Dimension Drawings, Engineered motors, AMA, IC81W 112
Dimension Drawings, Engineered motors, AMA, IC611 118

ABB reserves the right to change the design,


technical specification and dimensions
without prior notice.

46 ABB/ BU Machines / HV Induction motors IEC catalogue / Engineered motors EN 05-2006


General Information
ABB's engineered motors are tailor-made to meet its The AMA range features a welded steel frame and is
customers' needs. All ABB engineered motors are available as standard with the following cooling methods
configured and optimized individually for each order and and protection types: IC 01 / IP 24W, IC 611 / IP 55 and
application. Please contact ABB for further information. IC 81W / IP 55. The standard shaft heights are between
400 and 500 mm.
This catalogue contains information on ABB’s standard
construction squirrel-cage induction motors operating at The HXR range features a rugged cast iron frame and
50 Hz and with synchronous speed from 500 to is totally enclosed fan cooled motor of IC 411 / IP 55.
3000 rpm. The output range is up to 2800 kW. HXR motors have standard shaft heights between 355
and 560 mm.
This catalogue describes two different motor types,
the AMA range and the HXR range. Both motor types The table below shows the available output power,
can be operated with variable speed drives or used voltage range and pole numbers.
as induction generators and motors can be mounted
horizontally or vertically. Either motor can be used for
both standard and special applications.

Output (kW) at 50 Hz Output (kW) at 50 Hz


HXR AMA
Poles 3 kV 6 kV 10 kV 3 kV 6 kV 10 kV
2 100 - 1730 160 - 1600 400 - 1250 630 - 2500 630 - 2500 560 - 1800
4 400 - 2240 100 - 2000 355 - 1400 630 - 2800 630 - 2800 630 - 2240
6 100 - 2000 100 - 1800 315 - 1400 450 - 2250 450 - 2250 450 - 1600
8 200 - 1800 180 - 1600 315 - 1120 280 - 1600 280 - 1600 630 - 1250
10 224 - 1400 224 - 1250 560 - 710 200 - 1120 200 - 1120 450 - 1000
12 450 - 1120 400 - 1000 - 140 - 900 140 - 900 315 - 710 2
Output ranges of ABB motors (Temperature rise class B, insulation class F). Other voltages on request.

Mounting arrangement
Standard mounting arrangements for AMA motors. Other mountings on request.

Code I: IM B3 Code I: IM V1
Code II: IM 1001 Code II: IM 4011
Horizontal foot mounted Vertical flange mounted
(free shaft end facing downwards)

ABB/ BU Machines / HV Induction motors IEC catalogue / Engineered motors EN 05-2006 47


Standard mounting arrangements for HXR motors

Code I: IM B3 Code I: IM V1
Code II: IM 1001 Code II: IM 3011
Standard floor mounting, feet facing downwards Flange and free shaft end facing downwards
(Horizontal foot mounted) (Vertical solid shaft, flange mounted)

48 ABB/ BU Machines / HV Induction motors IEC catalogue / Engineered motors EN 05-2006


Enclosure and Cooling
Standard combinations used for AMA-motors are:

IC 01 / IP 24W
This weather-protected motor has a shaft-mounted
cooling fan located inside the housing. The design of the
motor reduces the ingress of rain, snow and airborne
particles into the electrical parts. On the air intake path
this is achieved by ensuring that the average velocity
does not exceed 3 m/s, allowing any heavier particles to
settle. The design of air intake path includes three acute
changes in excess of 90 degrees to further reduce the
flow rate to the optimum level. The motor is protected
against splashing water from any direction.

IC 611 / IP 55
In this design the fully enclosed motor has an air-
to-air heat exchanger mounted on the motor. Shaft
mounted fans are fitted both inside and outside of the
casing to supply the inside and outside cooling circuits
respectively. The motor is protected against dust and
splashing water from any direction.
2

IC 81W / IP 55
This fully enclosed motor is fitted with an air-to-water
heat exchanger. A shaft mounted fan is fitted inside the
casing to supply the internal cooling circuit. Motor is
protected against dust and splashing water from any
direction.

The terminal boxes have a protection of at least IP 55.

ABB/ BU Machines / HV Induction motors IEC catalogue / Engineered motors EN 05-2006 49


IC 31 / IP 55
This version is fitted with an inlet and outlet pipe to use
remote cooling air. Essentially this is the AMA-motor
frame without any upper cover. The motor is protected
against dust and splashing water from any direction.

IC 411 / IP55 HXR motor


The HXR motor has an external shaft mounted fan protected against dust and water jets. The principle of
that use the surrounding air for cooling. The motor is this motor is shown in below:

2
Sectional drawing of IC 411 / IP55 motor.

Protection definition IP55 Method of Cooling (IC 411)


In a dust-protected motor, some dust can ingress the Frame surface cooled:
motor but it does not enter in sufficient quantity to The primary coolant is circulated in a closed circuit
interfere with the motor's operation. in the motor and gives its heat through the external
surface of the motor (in addition to the heat transfer
The motor protected against water jets: via the stator core and other heat conducting parts) to
Water projected by a nozzle against the motor from any the final coolant which is the surrounding medium. The
direction shall have no harmful effect. surface may be plain or ribbed, with or without an outer
shell to improve the heat transfer.

Self circulation:
The coolant is moved dependent on the rotational
speed of the main motor either by action of the rotor
alone or by means of a component designed for this
purpose and mounted directly on the rotor of the main
motor, or by a fan or pump unit mechanically driven by
the rotor or the main motor.

50 ABB/ BU Machines / HV Induction motors IEC catalogue / Engineered motors EN 05-2006


Type designation
The type designation of the AMA motor follows the coding principle shown below.

Example: AMA 450L4A BATH


1 AM Stands for Alternating Current Machines
2 A Indicates the type of machine, A - E = SCIM, K - P = WRIM
3 450 Frame size in mm, 400, 450 or 500
4 L Frame length, S = small, M = medium or L = long
5 4 Number of poles
6 A Stands for the IC/IP combination
D = IC01 / IP23 [WP I] L = IC81W / IP54 (55) [TEWAC]
W = IC01 / IPW24 [WP II] A = IC611 / IP55 [TEAAC]
P = IC11, 21, 31 / IP23, 54 (55) [OPV, TEPV]
7 B Mounting arrangement, B = IM1001 (Horizontal), V = IM4011 (Vertical)
8 A Bearing type, A = antifriction, S = sleeve
9 T Indication of special construction
T = separate ventilation X = electrically special
N = Non-sparking design F = frequency converter drive Y = mechanically special
10 H Location of manufacture

The type designation of the HXR motor follows the coding principle shown below.

Example: HXR 355LA4


1. HXR Stands for the HXR machine family, three digits.
2. 355 Shaft height in mm, three digits.
3. L Frame length, one digit.
4. A Core length, one digit.
5. 4 Number of poles.

ABB/ BU Machines / HV Induction motors IEC catalogue / Engineered motors EN 05-2006 51


High voltage terminal box for IEC motors
The picture shows the high voltage terminal box with its
main technical data below.

Technical data:
Voltage (max.) 6.6 kV Materials:
Current (max.) 400 A Box welded sheet steel (thickness
Dynamic short circuit current 75 kA (0.25 s) min. 3 mm)
No of cables (max.) 1 per phase Cable gland plate steel
Cross section of cables (max.) 300 mm2/cable Connection screws Bronze Bz
Cable gland blind gland (1 pce) Isolators epoxy casting resin or
Clearance (min.) 60 mm polyurethane resin
Creepage (min.) 119 mm Grounding pad stainless steel
Gross volume 47.3 dm3
Usable volume 42.1 dm3 Other features:
Connection screws M16 (3 pcs) - rigid welded construction
Connection nuts tightening torque 40 Nm - ample size for making connections of supply cables
Ground connections M12 (both in- and out - box turnable to allow cable entry from left or right side
side) - box turnable in steps of 90°
Weight 33 kg - either 3-phase or 1-phase cables can be connected
Protection IP66 - pressure relief plate in the bottom of the box in case
Standard DIN 42962 TEIL 1, A2 of an arching short circuit
- different cable glands available
- terminal box tested acc. to IEC 298 concerning
internal arc strength

Figure above: High voltage terminal box. Dimensions in mm.

52 ABB/ BU Machines / HV Induction motors IEC catalogue / Engineered motors EN 05-2006


High voltage terminal box for IEC motors
Figure below shows the high voltage terminal box with
its main technical data.

Technical data: Materials:


Voltage (max.) 6.6 kV Box welded sheet steel (thickness
Current (max.) 800 A min. 3 mm)
No of cables (max.) 2 per phase Cable gland plate steel
Cross section of cables (max.) 300 mm2/cable Connection screws Bronze Bz
Cable gland blind gland (1 pce) Isolators polyurethane resin or epoxy
Clearance (min.) 70 mm casting resin
Creepage (min.) 119 mm Grounding pad stainless steel
Gross volume 194.6 dm3
Usable volume 186.5 dm3 Other features:
Connection screws (M16x1/M12x2/ - rigid welded construction
M10x2)/phase - ample size for making connections of supply cables
Tightening torque for - box turnable to allow cable entry from left or right side
connection nuts 40 Nm - box turnable in steps of 90°
Ground connections M12 (both in- and - either 3-phase or 1-phase cables can be connected
outside) - pressure relief plate in the bottom of the box in case
Weight 90 kg of an arching short circuit
Protection IP66 - different cable glands available
Standards DIN 42962 Teil 2, D2
(internal dimensions)

Figure above: High voltage terminal box. Dimensions in mm.

ABB/ BU Machines / HV Induction motors IEC catalogue / Engineered motors EN 05-2006 53


High voltage terminal box for IEC motors
The picture shows high voltage terminal box with its
main technical data below.

Technical data: Materials:


Voltage (max.) 11.0 kV Box welded sheet steel (thickness
Current (max.) 400 A min. 3 mm)
No of cables (max.) 1 per phase Cable gland plate steel
Cross section of cables (max.) 300 mm2/cable Connection screws Bronze Bz
Cable gland blind gland (1 pce) Isolators epoxy casting resin
Clearance (min.) 100 mm Grounding pad stainless steel
Creepage (min.) 158 mm
Gross volume 122 dm3 Other features:
Usable volume 116 dm3 - rigid welded construction
Connection screws M16 (3 pcs) - ample size for making connections of supply cables
Connection nuts tightening torque 40 Nm - box turnable to allow cable entry from left or right side
Ground connections M12 (both in- and - box turnable in steps of 90°
outside) - either 3-phase or 1-phase cables can be connected
Weight 62 kg - pressure relief plate in the bottom of the box in case
Protection IP66 of an arching short circuit
Standard DIN 42962 TEIL 2, C2 - different cable glands available

Figure above: High voltage terminal box. Dimensions in mm.

54 ABB/ BU Machines / HV Induction motors IEC catalogue / Engineered motors EN 05-2006


Dimensions for terminal box inlet, blind flange
As standard, main terminal boxes are with blind flange.
Cable glands are available on request.

Figure above: Blind flange FL 33 for main terminal box.

ABB/ BU Machines / HV Induction motors IEC catalogue / Engineered motors EN 05-2006 55


Auxiliary boxes
As standard motors in safe area are equipped with one As standard motors in hazardous area are equipped
common auxiliary terminal box for monitoring devices with two auxiliary terminal boxes, one for monitoring
and space heaters. devices and one for space heaters.

Type designation Use Size (W x L x H)


mm
ZWA ALX122208 Standard 125 x 222 x 81

ZWA ALX233318 Is used when additional space is needed 230 x 330 x 180

Table above: Standard auxiliary terminal boxes.

The typical arrangements for standard terminal boxes the motor. Additional terminals can be supplied on
are shown below. The number of terminal blocks request.
depends on the number of accessories equipped with

Standard terminal box ZWA ALX122208


with terminal blocks and cable glands.
1) Cable gland M20x1.5 for cable outer
diameter 10...14 mm (2 pcs)
2) Threaded hole for cable gland M16x1.5
(3 pcs), plugged.

Standard terminal box ZWA ALX233318


with terminal blocks and cable glands.
1) Cable gland M20x1.5 for cable outer
diameter 10...14 mm (4 pcs)
2) Threaded hole for cable gland M16x1.5
(3 pcs), plugged.

56 ABB/ BU Machines / HV Induction motors IEC catalogue / Engineered motors EN 05-2006


Bearings
Horizontal motors
Horizontal motors 355 - 500 have deep groove ball stated in table below and the bearing construction is
bearings in both ends. HXR 560 has a double bearing shown in the figures on page 58.
arrangement (deep groove ball bearing and a cylindrical
roller bearing) at D-end and cylindrical roller bearing at The standard bearing solution is designed to carry the
N-end (only horizontal motor available). weight of the typical coupling half and the weight of
the motor rotor only. Any additional radial or axial force
The bearing in D-end is axially locked in horizontal caused by driven equipment may need the bearings to
motors. Standard bearings of horizontal motors are be specially constructed.

Table below: Standard bearings for horizontal motors.

Frame size Poles D-end N-end

HXR 355 2 6317M/C3 6317M/C3


HXR 355 ≥4 6322/C3 6319/C3
HXR 400 2 6317M/C3 6317M/C3
HXR 400 ≥4 6324/C3 6319/C3
HXR 450 2 6317M/C3 6317M/C3
HXR 450 ≥4 6324/C3 6322/C3
HXR 500 2 6319M/C3 6319M/C3
HXR 500 ≥4 6326/C3 6324/C3
HXR 560
HXR 560
≥4
2
6034/C3 + NU1034/C3
sleeve*
NU322/C3
sleeve*
2
AMA 400 2 6319M/C3 6319M/C3
AMA 400 ≥4 6324/C3 6319/C3
AMA 450 2 6319M/C3 6319M/C3
AMA 450 ≥4 6326/C3 6322/C3
AMA 500 ≥4 6330/C3 6324/C3
AMA 500 2 sleeve* sleeve*
* See section sleeve bearings.

ABB/ BU Machines / HV Induction motors IEC catalogue / Engineered motors EN 05-2006 57


Figure below: Standard bearing construction for horizontally mounted motors, frame sizes 355-500.

1 Groove ball bearing


2 Inner bearing cover
3 Grease valve
4 Outer bearing cover
5 Circlip
6 Hexagon screw
7 Spring
8 O-ring

D-end, axially locked N-end, axially free

2 Figure below: Standard bearing construction for horizontally mounted motors HXR 560.

1 Inner bearing cover 1 Cylindrical roller bearing


2 Cylindrical roller bearing 2 Inner bearing cover
3 Grease valve 3 Grease valve
4 Outer bearing cover 4 Outer bearing cover
5 Deep groove ball bearing 5 Circlip
6 Outer bearing cover lid 6 Hexagon screw
7 Labyrinth seal
8 Grub screw

D-end, axially locked N-end, axially free

58 ABB/ BU Machines / HV Induction motors IEC catalogue / Engineered motors EN 05-2006


Bearing rating life
Most motors with standard bearings have a rated life The basic rated life L10h is the number of hours at rated
time L10h in excess of 100000 h. Rated life time for frame bearing load and speed that 90% of a group of identical
500, 2-pole, may be less than 100000h. The life times bearings will complete or exceed before the first
are calculated in accordance with ISO R 281-1. evidence of failure.

Lubrication intervals
The motors are equipped with greasing nipple(s) in grease and the interval of greasing are stamped on the
both ends for lubricating the bearings. The greasing relubrication plate. The values are also shown in the
nipples are located on top of the motor. The amount of table below.

Table below: Relubrication intervals and grease amount.

Bearing Amount of Lubrication intervals in running hours at different speeds [rpm]


type grease [g] 3600 3000 1800 - 1500 1200 - 1000 900 - 750 600 - 500

6317 35 800 2200 8800 8800 8800 8800


6319 45 400 1600 6600 8800 8800 8800
6322 60 6600 8800 8800 8800
6324 70 4400 8800 8800 8800
6326 80 4400 8800 8800 8800
6034 55 1600 3300 6600 8800
NU1034 55 1600 3300 4400 8800
NU322
7317
60
35 1100
3300
4400
4400
4400
4400
4400
8800
6600 2
7319 45 800 3300 4400 4400 6600
7322 60 3300 4400 4400 6600
7324 70 2200 4400 4400 6600
NB: Ball bearings on vertical motors should be lubricated twice as frequently as horizontal motors. The motor type is indicated by the first letter
of the bearing type (6).

ABB/ BU Machines / HV Induction motors IEC catalogue / Engineered motors EN 05-2006 59


Sleeve bearings
The axial float of rotor is as standard ±8 mm from Sleeve bearings are generally self-cooled, oil ring
mechanical center. The running center locates within lubricated but some require external flood lubrication.
the float area and therefore operation is also allowed Please see the lubrication table below for standard
while machine is uncoupled, e.g. during test run. A lubrication requirements based on a maximum 40 °C
pointer showing running center with regard to end limits ambient and 50 Hz operation. Consult ABB for ambient
is available as standard. Continuous axial forces are temperatures above 40 °C, and/or for self-cooling of
not permitted and therefore limiting type coupling is bearings where flood lubrication is standard. Those
needed to ensure rotor location within axial float range. units requiring flood lubrication are supplied with
On request, when special axial float is at least ±3 mm, provisions only. Refer oil supply pressure, type of oil,
magnetic running center can be adjusted within and location of provisions to factory for review prior to
±2.4 mm from mechanical center (option). order acceptance.

Table below: Sleeve bearings and lubrication method.

Frame size Poles D-end bearing N-end bearing Lubrication Method

HXR 355 2 EFZLB 9-80 EFZLQ 9-80 Oil circulation 1)


HXR 355 ≥4 EFZLB 9-90 EFZLQ 9-90 Self lubrication
HXR 400 2 EFZLB 9-80 EFZLQ 9-80 Oil circulation 1)
HXR 400 ≥4 EFZLB 9-100 EFZLQ 9-100 Self lubrication
HXR 450 2 EFZLB 9-80 EFZLQ 9-80 Oil circulation 1)
HXR 450 4 EFZLB 9-100 EFZLQ 9-100 Oil circulation 1)
HXR 450 ≥6 EFZLB 9-100 EFZLQ 9-100 Self lubrication
HXR 500 2 EFZLB 9-90 EFZLQ 9-90 Oil circulation 1)
HXR 500 4 EFZLB 11-100 EFZLQ 9-100 Oil circulation 1)

2 HXR 500
HXR 560
≥6
2
EFZLB 11-100
EFZLB 14-125
EFZLQ 9-100
EFZLQ 14-125
Self lubrication
Oil circulation
HXR 560 4 EFZLB 14-125 EFZLQ 14-125 Oil circulation 1)
HXR 560 6 EFZLB 14-125 EFZLQ 14-125 Self lubrication
HXR 560 ≥8 EFZLB 14-140 EFZLQ 14-140 Self lubrication
AMA 400 2 EFZLB 9-80 EFZLQ 9-80 Self lubrication
AMA 400 ≥4 EFZLB 9-100 EFZLQ 9-100 Self lubrication
AMA 450 2 EFZLB 9-80 EFZLQ 9-80 Self lubrication
AMA 450 ≥4 EFZLB 11-125 EFZLQ 9-100 Self lubrication
AMA 500 2 EFZLB 9-100 EFZLQ 9-100 Oil circulation 1)
AMA 500 4 EFZLB 14-125 EFZLQ 11-125 Self lubrication
AMA 500 ≥6 EFZLB 14-140 EFZLQ 11-125 Self lubrication
1)
Possibility for self lubrication, please contact ABB

60 ABB/ BU Machines / HV Induction motors IEC catalogue / Engineered motors EN 05-2006


Vertical motors
Vertical motors 355 - 500 have deep groove ball bearing Standard bearing solution is designed to carry the
in D-end and single-row angular contact ball bearing in weight of the typical coupling half and the weight of
N-end. the motor rotor only. Any additional radial or axial
force caused by driven equipment may require special
The bearing in D-end is axially free in vertical machines bearing construction.
when an angular contact ball bearing is mounted in
N-end. Standard bearings of vertical machines are
stated in table below and the bearing construction is
shown in figure below.

Table below: Standard bearings for vertical motors.

Frame size Poles D-end N-end

HXR 355 2 6317M/C3 7317 BMP 1)


HXR 355 ≥4 6322/C3 7319 BMP
HXR 400 2 6317M/C3 7317 BMP 2)
HXR 400 ≥4 6324/C3 7319 BMP
HXR 450 ≥4 6324/C3 7322 BMP
HXR 500 ≥4 6326/C3 7324 BMP
AMA 400 ≥4 6324/C3 7319 BMP
AMA 450 ≥4 6326/C3 7322 BMP
AMA 500 ≥4 6330/C3 7324 BMP
1)
60 Hz motors have ball bearing 6317M/C3.
2)
Only for 50 Hz motors.

Figure below: Standard bearing construction of vertically mounted motor, frame sizes 355 - 500. On the left the
bearing is "axially locked" angular contact ball bearing and on the right is an axially free deep 2
groove ball bearing.

1 Bearing 5 Circlip
2 Inner bearing cover 6 Hexagon screw
3 Grease valve 7 Spring
4 Outer bearing cover 8 O-ring

ABB/ BU Machines / HV Induction motors IEC catalogue / Engineered motors EN 05-2006 61


Bearing rating life
The bearing rates for all vertical motors with standard bearings will complete or exceed before the first
bearings have a rated life time L10h in excess of evidence of failure.
100000 h. The life times are calculated in accordance
with ISO R 281-1. Additional axial force from the driven equipment is not
allowed.
The basic rated life L10h is the number of hours at rated
bearing load and speed that 90% of a group of identical

Lubrication intervals
The motors are equipped with greasing nipple(s) in relubrication plate. The values are also available in the
both ends for lubricating the bearings. The amount of table on page 59.
grease and the interval of greasing are stamped on the

Vibrations
Standard design
The standard motors manufactured according to IEC-
standard satisfy the Grade A vibration limits found in
IEC 60034-14. The table below shows the maximum
accepted values.

2 Table below: Standard design unfiltered vibration limits for IEC motors.

Poles Speed [rpm] Bearing housing Relative shaft Combined runout


vibration vibration
2 1800 < n ≤ 3600 2.3 mm/s rms 65 µm p-p 16 µm p-p
≥4 n ≤ 1800 2.3 mm/s rms 90 µm p-p 23 µm p-p

62 ABB/ BU Machines / HV Induction motors IEC catalogue / Engineered motors EN 05-2006


Notes
All ratings in this catalogue are designed for the
following:
- Class F insulation / Maximum temperature rise of
80 °C by resistance
- Maximum 40 °C ambient
- Altitude of 1000 meters or less
- Data presented in rating lists are typical values.
Guaranteed values are available on request.
All engineered motors are optimized for the
specified application. Accurate motor data will be
given on request at quotation phase. Legally binding
performance and specification data is given to the end
user once each order is confirmed.
- Please provide load data and starting requirements to
ABB for final design confirmation.

ABB/ BU Machines / HV Induction motors IEC catalogue / Engineered motors EN 05-2006 63


HV Cast iron motors, HXR 3000 V - 50 Hz
Technical data for totally enclosed squirrel
cage three phase motors
IP 55 - IC 411 - Insulation class F, temperature rise class B

Efficiency Power factor Current Torque Sound


Full 3/4 Full 3/4 IN IS I0 TN TS Tmax Rotor Motor pressure
Output Motor Product Speed load load load load inertia weight level LP
kW type ID r/min 100% 75% 100% 75% A IN A Nm TN TN kgm2 kg dB(A)

3000 r/min = 2 poles 3000 V 50 Hz


100 HXR 355LA2 25 2962 93.0 92.5 0.91 0.90 23 5.3 6 322 0.6 2.3 2.7 1570 85
125 HXR 355LA2 26 2966 93.8 93.4 0.91 0.89 28 5.6 7 402 0.6 2.4 2.7 1570 85
160 HXR 355LA2 27 2967 94.5 94.3 0.92 0.91 35 5.6 8 515 0.6 2.3 3.0 1650 85
200 HXR 355LA2 28 2967 94.9 94.8 0.92 0.91 44 5.6 9 644 0.6 2.3 3.0 1650 85
224 HXR 355LA2 29 2968 95.1 95.1 0.91 0.90 50 5.6 11 721 0.6 2.3 2.9 1650 85
250 HXR 355LB2 30 2969 95.4 95.3 0.91 0.90 55 5.7 13 804 0.6 2.3 3.1 1700 85
280 HXR 355LB2 31 2970 95.6 95.6 0.91 0.90 62 5.9 14 900 0.6 2.4 3.3 1750 85
315 HXR 355LD2 32 2970 95.8 95.9 0.92 0.92 69 6.0 14 1013 0.6 2.4 3.7 1890 85
355 HXR 400LC2 34 2981 96.1 95.9 0.90 0.89 79 6.2 20 1137 0.5 2.5 5.7 2590 82
400 HXR 400LD2 35 2980 96.2 96.1 0.90 0.89 89 6.1 21 1282 0.5 2.4 6.0 2630 82
450 HXR 400LE2 36 2982 96.5 96.4 0.90 0.88 100 6.1 24 1441 0.5 2.3 6.7 2810 82
500 HXR 400LF2 37 2982 96.6 96.5 0.90 0.89 111 6.2 26 1601 0.5 2.3 7.2 2930 82
560 HXR 400LG2 38 2982 96.8 96.7 0.90 0.89 123 6.4 28 1793 0.6 2.4 7.8 3050 82
630 HXR 450LG2 39 2984 96.7 96.5 0.91 0.90 137 6.3 31 2016 0.5 2.6 11.9 4000 85
710 HXR 450LJ2 40 2983 96.9 96.8 0.93 0.92 152 6.4 31 2273 0.5 2.6 13.8 4390 85
800 HXR 500LH2 42 2989 96.8 96.5 0.90 0.89 176 6.5 43 2556 0.5 2.6 23.6 5820 86

2 900
1000
1120
HXR 500LK2
HXR 500LL2
HXR 500LP2
43
44
45
2986
2988
2988
96.9
97.1
97.2
96.8
96.9
97.0
0.93
0.92
0.91
0.92
0.91
0.90
193 6.2
216 6.4
244 6.6
38
46
54
2878
3196
3579
0.5
0.5
0.5
2.5
2.5
2.5
25.7
27.6
31.3
6110
6380
6860
86
86
86
1250 HXR 500LQ2 46 2989 97.4 97.3 0.93 0.92 266 6.8 53 3994 0.5 2.6 32.7 7220 86
1400 HXR 560LM2 704 2989 97.3 97.2 0.92 0.90 301 6.8 70 4473 0.5 2.8 45.3 9810 87
1600 HXR 560LR2 705 2990 97.5 97.4 0.93 0.92 340 6.8 72 5111 0.5 2.7 52.7 10790 87
1730 HXR 560LS2 706 2991 97.6 97.5 0.92 0.91 371 7.1 84 5524 0.5 2.7 57.8 11360 87

Data presented in rating lists are typical values.


Guaranteed values on request. All engineered motors
are optimized for the specified application. Accurate
motor data will be given on request at quotation phase.
Legally binding performance and specification data is
given to the end user once each order is confirmed.

64 ABB/ BU Machines / HV Induction motors IEC catalogue / Engineered motors EN 05-2006


HV Cast iron motors, HXR 3000 V - 50 Hz
Technical data for totally enclosed squirrel
cage three phase motors
IP 55 - IC 411 - Insulation class F, temperature rise class B
Efficiency Power factor Current Torque Sound
Full 3/4 Full 3/4 IN IS I0 TN TS Tmax Rotor Motor pressure
Output Motor Product Speed load load load load inertia weight level LP
kW type ID r/min 100% 75% 100% 75% A IN A Nm TN TN kgm2 kg dB(A)

1500 r/min = 4 poles 3000 V 50 Hz


100 HXR 355LA4 131 1487 93.9 93.2 0.83 0.79 25 5.7 10 642 0.9 2.3 4.7 1620 77
125 HXR 355LA4 132 1485 94.3 93.9 0.84 0.80 31 5.6 12 804 0.9 2.2 4.7 1620 77
160 HXR 355LA4 133 1485 94.7 94.5 0.85 0.82 38 5.6 14 1029 0.9 2.2 4.8 1630 77
200 HXR 355LA4 134 1484 95.0 94.9 0.85 0.82 48 5.4 17 1287 0.8 2.1 4.8 1630 77
224 HXR 355LA4 135 1485 95.2 95.2 0.85 0.82 53 5.6 18 1441 0.9 2.1 5.1 1670 77
250 HXR 355LB4 136 1485 95.5 95.4 0.85 0.82 59 5.7 21 1607 0.9 2.1 5.4 1720 77
280 HXR 355LB4 137 1486 95.7 95.6 0.84 0.81 67 5.8 24 1799 0.9 2.1 5.7 1770 77
315 HXR 355LC4 138 1487 95.9 95.8 0.84 0.81 75 5.8 27 2023 0.9 2.1 6.3 1870 77
355 HXR 355LE4 139 1487 96.1 96.1 0.85 0.82 84 5.9 29 2280 0.9 2.1 7.2 2020 77
400 HXR 400LC4 140 1491 96.4 96.3 0.86 0.83 93 6.1 32 2562 0.8 2.2 11.3 2630 76
450 HXR 400LD4 141 1490 96.6 96.6 0.87 0.85 103 6.0 31 2884 0.8 2.1 12.5 2750 76
500 HXR 400LE4 142 1490 96.7 96.7 0.88 0.86 113 6.0 32 3204 0.8 2.1 13.6 2880 76
560 HXR 400LG4 143 1491 96.9 96.8 0.87 0.85 128 6.4 40 3586 0.9 2.2 15.1 3070 76
630 HXR 400LH4 144 1491 97.0 97.0 0.88 0.86 142 6.4 43 4034 0.9 2.2 16.8 3270 76
710 HXR 450LG4 145 1492 97.1 97.1 0.88 0.86 160 6.3 48 4545 0.8 2.3 26.6 4170 77
800 HXR 450LJ4 146 1492 97.2 97.2 0.88 0.86 180 6.3 52 5120 0.8 2.2 29.3 4420 77
900
1000
1120
HXR 450LL4
HXR 500LJ4
HXR 500LK4
147
148
149
1492
1491
1492
97.3
97.2
97.4
97.3
97.3
97.4
0.88
0.90
0.90
0.86
0.88
0.89
201 6.4 58
220 6.2 58
246 6.0 62
5760
6404
7167
0.8
0.7
0.7
2.2
2.4
2.2
32.9
48.3
52.9
4740
6010
6310
77
77
77
2
1250 HXR 500LL4 150 1492 97.4 97.5 0.90 0.89 274 5.9 68 7999 0.7 2.2 55.6 6510 77
1400 HXR 500LP4 151 1493 97.6 97.6 0.89 0.88 309 6.1 83 8953 0.6 2.3 63.5 7090 77
1600 HXR 560LK4 627 1494 97.7 97.7 0.90 0.88 352 6.5 95 10229 0.7 2.4 89.0 9410 82
1800 HXR 560LP4 628 1495 97.8 97.7 0.89 0.86 399 6.7 119 11500 0.6 2.5 107.2 10330 82
2000 HXR 560LS4 629 1495 97.9 97.9 0.89 0.87 441 6.9 127 12777 0.7 2.5 126.9 11350 82
2240 HXR 560LT4 630 1496 98.0 97.9 0.87 0.85 504 6.9 161 14298 0.6 2.3 139.1 11980 82

Data presented in rating lists are typical values.


Guaranteed values on request. All engineered motors
are optimized for the specified application. Accurate
motor data will be given on request at quotation phase.
Legally binding performance and specification data is
given to the end user once each order is confirmed.

ABB/ BU Machines / HV Induction motors IEC catalogue / Engineered motors EN 05-2006 65


HV Cast iron motors, HXR 3000 V - 50 Hz
Technical data for totally enclosed squirrel
cage three phase motors
IP 55 - IC 411 - Insulation class F, temperature rise class B

Efficiency Power factor Current Torque Sound


Full 3/4 Full 3/4 IN IS I0 TN TS Tmax Rotor Motor pressure
Output Motor Product Speed load load load load inertia weight level LP
kW type ID r/min 100% 75% 100% 75% A IN A Nm TN TN kgm2 kg dB(A)

1000 r/min = 6 poles 3000 V 50 Hz


160 HXR 355LA6 246 988 94.6 94.5 0.78 0.73 42 5.1 19 1546 1.1 2.0 5.4 1660 75
180 HXR 355LB6 247 988 94.9 94.9 0.79 0.74 46 5.3 21 1740 1.2 2.0 5.7 1700 75
200 HXR 355LC6 248 988 95.1 95.1 0.80 0.76 51 5.1 21 1934 1.1 1.9 6.3 1800 75
224 HXR 355LC6 249 988 95.3 95.3 0.80 0.76 57 5.3 24 2165 1.2 1.9 6.6 1850 75
250 HXR 355LD6 250 988 95.4 95.4 0.80 0.76 63 5.4 26 2416 1.2 1.9 7.2 1940 75
280 HXR 355LE6 251 989 95.6 95.6 0.80 0.75 71 5.6 30 2704 1.3 2.0 7.9 2040 75
315 HXR 355LF6 252 991 95.9 95.9 0.78 0.73 81 5.7 38 3036 1.1 2.1 8.2 2100 75
355 HXR 400LD6 253 992 96.1 96.1 0.83 0.79 86 5.9 33 3417 1.1 2.0 18.3 2710 75
400 HXR 400LF6 254 993 96.3 96.3 0.83 0.80 96 6.0 36 3848 1.1 2.0 20.8 2900 75
450 HXR 400LH6 255 993 96.4 96.4 0.83 0.79 109 6.0 41 4327 1.0 2.0 24.0 3140 75
500 HXR 400LK6 256 994 96.6 96.5 0.82 0.77 122 6.2 50 4804 1.0 2.1 28.0 3460 75
560 HXR 450LF6 257 993 96.8 96.8 0.85 0.83 131 5.8 43 5388 1.0 2.0 34.7 3970 76
630 HXR 450LH6 258 993 96.8 96.9 0.86 0.83 146 5.9 47 6060 1.0 2.0 38.7 4200 76
710 HXR 450LK6 259 993 97.0 97.0 0.86 0.83 165 5.9 53 6828 1.0 2.0 44.0 4540 76
800 HXR 450LM6 260 994 97.1 97.1 0.85 0.83 186 6.1 62 7689 1.0 2.1 50.5 4930 76
900 HXR 500LG6 261 994 97.1 97.2 0.86 0.84 207 6.0 66 8648 0.9 2.1 58.1 5680 77

2 1000
1120
1250
HXR 500LJ6
HXR 500LN6
HXR 500LQ6
262
263
264
994
995
995
97.2
97.4
97.5
97.3
97.4
97.5
0.87
0.86
0.86
0.85
0.84
0.83
227 5.9 68
256 6.1 83
288 6.2 98
9611 0.9
10754 0.9
11998 0.9
2.1
2.2
2.2
66.0
81.2
88.7
6080
6860
7250
77
77
77
1400 HXR 500LR6 265 995 97.5 97.5 0.84 0.81 327 6.4 122 13430 0.8 2.3 97.5 7690 77
1600 HXR 560LN6 631 995 97.6 97.6 0.87 0.84 363 6.4 118 15348 0.8 2.3 141.4 10060 81
1800 HXR 560LR6 632 996 97.7 97.7 0.87 0.84 409 6.6 135 17262 0.8 2.4 168.7 11060 81
2000 HXR 560LU6 633 996 97.8 97.8 0.88 0.86 445 6.6 133 19171 0.7 2.4 206.5 12330 81

Data presented in rating lists are typical values.


Guaranteed values on request. All engineered motors
are optimized for the specified application. Accurate
motor data will be given on request at quotation phase.
Legally binding performance and specification data is
given to the end user once each order is confirmed.

66 ABB/ BU Machines / HV Induction motors IEC catalogue / Engineered motors EN 05-2006


HV Cast iron motors, HXR 3000 V - 50 Hz
Technical data for totally enclosed squirrel
cage three phase motors
IP 55 - IC 411 - Insulation class F, temperature rise class B
Efficiency Power factor Current Torque Sound
Full 3/4 Full 3/4 IN IS I0 TN TS Tmax Rotor Motor pressure
Output Motor Product Speed load load load load inertia weight level LP
kW type ID r/min 100% 75% 100% 75% A IN A Nm TN TN kgm2 kg dB(A)

750 r/min = 8 poles 3000 V 50 Hz


200 HXR 400LB8 360 741 94.9 95.1 0.81 0.78 50 5.0 20 2577 1.0 1.9 15.1 2460 75
224 HXR 400LC8 361 741 95.1 95.3 0.82 0.78 55 5.0 22 2886 1.0 1.9 16.8 2580 75
250 HXR 400LE8 362 741 95.4 95.6 0.83 0.79 61 5.0 23 3221 1.0 1.9 19.3 2770 75
280 HXR 400LF8 363 742 95.5 95.7 0.83 0.79 68 5.0 26 3605 1.0 1.9 21.8 2950 75
315 HXR 400LH8 364 742 95.7 95.9 0.82 0.78 78 5.2 31 4052 1.0 2.0 24.2 3140 75
355 HXR 400LJ8 365 742 95.8 96.0 0.82 0.79 87 5.1 33 4568 1.0 2.0 26.8 3330 75
400 HXR 450LD8 366 743 95.9 96.0 0.83 0.80 96 5.3 35 5143 0.9 2.0 30.0 3610 78
450 HXR 450LE8 367 743 96.0 96.1 0.83 0.80 108 5.3 40 5786 0.9 2.0 31.3 3700 78
500 HXR 450LG8 368 743 96.2 96.3 0.83 0.80 120 5.5 45 6423 0.9 2.0 38.1 4100 78
560 HXR 450LH8 369 744 96.3 96.3 0.83 0.79 135 5.5 52 7192 0.9 2.0 40.7 4260 78
630 HXR 450LL8 370 744 96.4 96.4 0.82 0.79 153 5.7 60 8085 0.9 2.1 48.7 4720 78
710 HXR 500LF8 371 745 96.4 96.4 0.82 0.78 173 5.6 68 9101 0.9 2.0 55.0 5470 78
800 HXR 500LH8 372 745 96.5 96.5 0.82 0.78 194 5.6 76 10253 0.9 2.0 61.0 5780 78
900 HXR 500LK8 373 745 96.7 96.6 0.82 0.78 218 5.6 85 11532 0.9 2.0 68.9 6170 78
1000 HXR 500LN8 374 745 96.6 96.6 0.82 0.79 242 5.4 90 12821 0.9 1.9 80.1 6740 78
1120 HXR 500LP8 375 745 96.8 96.8 0.83 0.80 268 5.6 97 14353 0.9 1.9 84.8 6910 78
1250
1400
1600
HXR 500LR8
HXR 560LN8
HXR 560LR8
376
634
635
745
746
747
96.9
97.3
97.5
96.9
97.3
97.4
0.82
0.82
0.82
0.79
0.78
0.78
301 5.6 114
339 5.8 137
387 5.9 154
16013 0.9
17919 0.8
20460 0.9
2.0
2.1
2.0
94.5
143.3
172.5
7430
10050
11020
78
80
80
2
1800 HXR 560LU8 636 747 97.6 97.5 0.81 0.77 440 5.8 180 23009 0.8 2.0 210.6 12390 80

Data presented in rating lists are typical values.


Guaranteed values on request. All engineered motors
are optimized for the specified application. Accurate
motor data will be given on request at quotation phase.
Legally binding performance and specification data is
given to the end user once each order is confirmed.

ABB/ BU Machines / HV Induction motors IEC catalogue / Engineered motors EN 05-2006 67


HV Cast iron motors, HXR 3000 V - 50 Hz
Technical data for totally enclosed squirrel
cage three phase motors
IP 55 - IC 411 - Insulation class F, temperature rise class B

Efficiency Power factor Current Torque Sound


Full 3/4 Full 3/4 IN IS I0 TN TS Tmax Rotor Motor pressure
Output Motor Product Speed load load load load inertia weight level LP
kW type ID r/min 100% 75% 100% 75% A IN A Nm TN TN kgm2 kg dB(A)

600 r/min = 10 poles 3000 V 50 Hz


160 HXR 400LC10 455 594 94.2 93.9 0.70 0.64 46 4.8 26 2572 1.0 2.0 16.9 2580 75
180 HXR 400LD10 456 594 94.4 94.2 0.72 0.66 51 4.8 28 2895 1.0 1.9 18.6 2710 75
200 HXR 400LE10 457 594 94.5 94.3 0.71 0.65 57 4.8 31 3215 1.0 1.9 19.7 2800 75
224 HXR 400LF10 458 594 94.7 94.5 0.72 0.66 63 4.8 34 3601 1.0 1.9 21.9 2970 75
250 HXR 400LH10 459 594 94.9 94.7 0.72 0.66 70 4.8 38 4018 1.0 2.0 24.4 3160 75
280 HXR 400LK10 460 594 95.0 94.8 0.73 0.66 78 4.9 41 4499 1.0 2.0 28.3 3450 75
315 HXR 450LG10 461 595 95.8 95.8 0.76 0.70 84 5.1 41 5059 1.0 2.0 38.1 4090 75
355 HXR 450LJ10 462 595 95.9 96.0 0.76 0.71 93 5.1 45 5701 1.0 2.0 42.2 4330 75
400 HXR 450LK10 463 595 96.0 96.0 0.76 0.70 106 5.3 52 6422 1.0 2.1 46.3 4570 75
450 HXR 450LM10 464 595 96.2 96.1 0.75 0.69 120 5.3 61 7222 1.0 2.1 51.6 4900 75
500 HXR 500LH10 465 595 96.5 96.6 0.78 0.72 129 5.2 60 8025 0.9 2.0 62.6 5860 76
560 HXR 500LK10 466 595 96.5 96.6 0.79 0.74 142 5.1 63 8990 0.9 2.0 70.6 6220 76
630 HXR 500LM10 467 595 96.6 96.7 0.79 0.74 159 5.2 70 10113 0.9 2.0 78.5 6610 76
710 HXR 500LN10 468 595 96.6 96.7 0.79 0.75 179 5.0 76 11402 0.9 1.9 82.5 6820 76
800 HXR 500LP10 469 594 96.6 96.7 0.79 0.75 201 4.9 83 12851 0.9 1.9 86.5 7010 76
900 HXR 500LR10 470 595 96.7 96.8 0.79 0.74 227 5.2 98 14448 0.9 2.0 98.5 7600 76
1000 HXR 560LN10 637 597 97.0 97.0 0.77 0.73 256 5.0 115 16006 0.7 1.9 144.8 10030 78

2 1120
1250
1400
HXR 560LQ10 638
HXR 560LS10 639
HXR 560LU10 640
597
597
597
97.1
97.1
97.2
97.0
97.1
97.0
0.77
0.78
0.75
0.72
0.73
0.69
289 5.2 135
318 5.0 139
368 5.8 187
17921 0.8
20006 0.7
22384 0.9
2.0
1.9
2.2
159.0
180.3
212.3
10520
11270
12390
78
78
78

500 r/min = 12 poles 3000 V 50 Hz


140 HXR 400LD12 541 494 93.6 93.4 0.67 0.61 43 4.3 25 2707 1.0 1.8 18.5 2710 75
160 HXR 400LE12 542 494 93.8 93.6 0.68 0.62 48 4.2 28 3094 1.0 1.8 20.2 2830 75
180 HXR 400LG12 543 494 94.0 93.9 0.70 0.63 53 4.1 29 3482 1.0 1.7 22.7 3030 75
200 HXR 400LH12 544 494 93.9 93.7 0.69 0.63 59 4.2 33 3867 1.0 1.8 25.3 3210 75
224 HXR 400LK12 545 494 94.1 93.8 0.68 0.61 68 4.3 39 4327 1.0 1.8 27.6 3390 75
250 HXR 450LH12 546 495 94.9 94.7 0.71 0.65 72 4.3 38 4827 0.9 1.8 39.5 4180 75
280 HXR 450LJ12 547 494 95.0 94.9 0.71 0.66 79 4.1 41 5408 0.8 1.7 42.3 4370 75
315 HXR 450LL12 548 495 95.1 95.0 0.71 0.66 89 4.3 47 6081 0.9 1.8 49.1 4750 75
355 HXR 450LM12 549 495 95.1 95.0 0.71 0.65 101 4.3 53 6853 0.9 1.8 51.8 4910 75
400 HXR 500LJ12 550 495 95.5 95.4 0.71 0.65 114 4.3 60 7717 0.8 1.8 66.2 6040 75
450 HXR 500LL12 551 495 95.6 95.5 0.72 0.66 126 4.4 66 8683 0.9 1.8 72.3 6340 75
500 HXR 500LN12 552 495 95.7 95.6 0.72 0.66 140 4.4 72 9648 0.9 1.8 80.2 6740 75
560 HXR 500LQ12 553 495 95.6 95.5 0.71 0.66 158 4.4 82 10803 0.9 1.8 88.1 7100 75
630 HXR 500LR12 554 495 95.7 95.6 0.72 0.67 176 4.4 89 12157 0.9 1.8 92.2 7300 75
710 HXR 500LS12 555 495 95.8 95.7 0.71 0.66 200 4.4 104 13695 0.9 1.8 104.0 7890 75
800 HXR 560LM12 641 496 96.5 96.6 0.77 0.72 207 4.5 95 15407 0.7 1.9 133.3 9610 76
900 HXR 560LQ12 642 496 96.6 96.6 0.78 0.74 230 4.4 100 17335 0.7 1.8 158.1 10450 76
1000 HXR 560LS12 643 496 96.7 96.7 0.77 0.72 258 4.7 119 19247 0.7 2.0 179.3 11210 76
1120 HXR 560LU12 644 497 96.9 96.8 0.75 0.69 297 5.1 149 21512 0.8 2.1 212.4 12320 76
Data presented in rating lists are typical values.
Guaranteed values on request. All engineered motors
are optimized for the specified application. Accurate
motor data will be given on request at quotation phase.
Legally binding performance and specification data is
given to the end user once each order is confirmed.

68 ABB/ BU Machines / HV Induction motors IEC catalogue / Engineered motors EN 05-2006


HV Cast iron motors, HXR 6000 V - 50 Hz
Technical data for totally enclosed squirrel
cage three phase motors
IP 55 - IC 411 - Insulation class F, temperature rise class B
Efficiency Power factor Current Torque Sound
Full 3/4 Full 3/4 IN IS I0 TN TS Tmax Rotor Motor pressure
Output Motor Product Speed load load load load inertia weight level LP
kW type ID r/min 100% 75% 100% 75% A IN A Nm TN TN kgm2 kg dB(A)

3000 r/min = 2 poles 6000 V 50 Hz


160 HXR 355LA2 48 2969 94.2 94.0 0.90 0.89 18 5.6 5 515 0.6 2.4 3.0 1630 85
180 HXR 355LA2 49 2965 94.2 94.2 0.91 0.90 20 5.4 5 580 0.6 2.2 3.0 1630 85
200 HXR 355LA2 50 2970 94.6 94.5 0.90 0.89 23 5.5 6 643 0.5 2.3 3.0 1630 85
224 HXR 355LB2 51 2972 95.0 94.9 0.90 0.87 25 6.3 7 720 0.7 2.5 3.3 1730 85
250 HXR 355LB2 52 2976 95.3 95.2 0.91 0.89 28 6.4 7 802 0.6 2.6 3.2 1720 85
280 HXR 355LD2 53 2978 95.5 95.4 0.90 0.88 31 6.4 8 898 0.6 2.5 3.7 1840 85
315 HXR 400LB2 54 2979 95.7 95.5 0.91 0.89 35 6.2 9 1010 0.5 2.5 5.2 2430 82
355 HXR 400LC2 55 2981 95.9 95.8 0.90 0.89 39 6.3 10 1137 0.6 2.5 5.7 2530 82
400 HXR 400LD2 56 2981 96.2 96.1 0.92 0.90 44 6.3 10 1281 0.5 2.5 6.1 2640 82
450 HXR 400LF2 57 2982 96.4 96.4 0.92 0.91 49 6.4 11 1441 0.5 2.4 7.1 2880 82
500 HXR 400LG2 58 2983 96.6 96.5 0.91 0.90 55 6.4 12 1601 0.5 2.4 7.3 2940 82
560 HXR 450LF2 59 2984 96.5 96.3 0.92 0.91 61 6.4 13 1792 0.5 2.6 11.4 3870 85
630 HXR 450LH2 60 2983 96.7 96.6 0.93 0.92 67 6.3 14 2016 0.5 2.5 13.0 4170 85
690 HXR 450LK2 61 2984 96.8 96.7 0.93 0.92 74 6.4 15 2208 0.5 2.6 14.1 4410 85
710 HXR 500LG2 62 2988 96.6 96.3 0.91 0.89 78 6.4 19 2269 0.5 2.6 22.4 5570 86
800 HXR 500LH2 63 2987 96.7 96.5 0.92 0.90 87 6.4 19 2557 0.5 2.6 23.7 5760 86
900
1000
1120
HXR 500LL2
HXR 500LN2
HXR 500LQ2
64
65
66
2987
2987
2988
96.9
97.1
97.2
96.7
97.0
97.1
0.92
0.93
0.92
0.91
0.92
0.90
97 6.4
107 6.4
121 6.6
21
20
26
2877
3197
3579
0.5
0.5
0.5
2.5
2.5
2.5
26.9
30.2
32.1
6230
6690
6970
86
86
86
2
1250 HXR 560LM2 707 2986 97.1 97.0 0.92 0.91 134 6.8 32 3997 0.5 2.8 46.0 9680 87
1400 HXR 560LN2 708 2988 97.3 97.2 0.92 0.90 151 6.9 36 4474 0.5 2.7 48.2 10030 87
1600 HXR 560LS2 709 2991 97.5 97.3 0.91 0.89 174 6.9 43 5109 0.5 2.6 58.9 11230 87

Data presented in rating lists are typical values.


Guaranteed values on request. All engineered motors
are optimized for the specified application. Accurate
motor data will be given on request at quotation phase.
Legally binding performance and specification data is
given to the end user once each order is confirmed.

ABB/ BU Machines / HV Induction motors IEC catalogue / Engineered motors EN 05-2006 69


HV Cast iron motors, HXR 6000 V - 50 Hz
Technical data for totally enclosed squirrel
cage three phase motors
IP 55 - IC 411 - Insulation class F, temperature rise class B

Efficiency Power factor Current Torque Sound


Full 3/4 Full 3/4 IN IS I0 TN TS Tmax Rotor Motor pressure
Output Motor Product Speed load load load load inertia weight level LP
kW type ID r/min 100% 75% 100% 75% A IN A Nm TN TN kgm2 kg dB(A)

1500 r/min = 4 poles 6000 V 50 Hz


160 HXR 355LA4 154 1486 94.5 94.2 0.84 0.80 19 5.7 7 1028 0.9 2.1 5.0 1640 77
180 HXR 355LA4 155 1486 94.7 94.4 0.82 0.78 22 5.7 9 1156 0.9 2.1 5.0 1640 77
200 HXR 355LA4 156 1485 94.7 94.6 0.84 0.80 24 5.5 9 1286 0.9 2.0 5.0 1640 77
224 HXR 355LA4 157 1487 95.3 95.1 0.82 0.77 28 6.2 12 1438 1.0 2.3 5.1 1650 77
250 HXR 355LB4 158 1486 95.2 95.1 0.83 0.79 31 5.9 12 1606 1.0 2.1 5.6 1740 77
280 HXR 355LC4 159 1487 95.3 95.3 0.84 0.81 34 6.1 13 1798 1.0 2.2 6.0 1780 77
315 HXR 355LD4 160 1488 95.6 95.6 0.84 0.81 38 6.2 14 2022 1.0 2.2 7.2 1970 77
355 HXR 400LB4 161 1489 96.1 96.1 0.88 0.85 41 5.9 12 2277 0.8 2.1 10.4 2480 76
400 HXR 400LC4 162 1489 96.3 96.3 0.88 0.86 46 6.1 14 2565 0.9 2.2 11.4 2610 76
450 HXR 400LD4 163 1490 96.5 96.5 0.87 0.85 51 6.1 16 2884 0.9 2.2 12.5 2720 76
500 HXR 400LE4 164 1490 96.6 96.6 0.88 0.86 57 6.1 17 3204 0.9 2.1 13.6 2850 76
560 HXR 400LG4 165 1491 96.8 96.8 0.87 0.85 64 6.2 19 3587 0.9 2.2 15.6 3100 76
630 HXR 450LE4 166 1492 96.9 96.8 0.87 0.84 72 6.5 24 4031 0.8 2.4 22.9 3810 77
710 HXR 450LG4 167 1492 97.0 97.0 0.88 0.86 80 6.3 24 4545 0.8 2.3 26.6 4130 77
800 HXR 450LJ4 168 1492 97.2 97.2 0.88 0.87 90 6.2 25 5121 0.8 2.2 30.2 4450 77
900 HXR 500LF4 170 1491 97.1 97.1 0.89 0.87 101 5.9 28 5763 0.7 2.2 39.8 5430 77

2 1000
1120
1250
HXR 500LG4
HXR 500LJ4
HXR 500LP4
171
172
173
1492
1493
1493
97.2
97.3
97.5
97.2
97.3
97.5
0.88
0.88
0.88
0.87
0.86
0.86
112 5.9
126 6.3
140 6.2
32
37
42
6401
7166
7994
0.7
0.7
0.7
2.2
2.3
2.3
43.8
49.3
63.0
5690
6080
7030
77
77
77
1400 HXR 500LR4 174 1493 97.6 97.6 0.88 0.86 157 6.2 47 8952 0.7 2.3 68.4 7420 77
1600 HXR 560LM4 645 1495 97.7 97.6 0.89 0.86 178 6.7 54 10223 0.6 2.5 95.2 9670 82
1800 HXR 560LR4 646 1495 97.8 97.7 0.89 0.87 199 6.7 58 11500 0.7 2.5 121.8 10970 82
2000 HXR 560LT4 647 1496 97.9 97.8 0.88 0.86 224 6.7 68 12767 0.6 2.3 136.9 11730 82

Data presented in rating lists are typical values.


Guaranteed values on request. All engineered motors
are optimized for the specified application. Accurate
motor data will be given on request at quotation phase.
Legally binding performance and specification data is
given to the end user once each order is confirmed.

70 ABB/ BU Machines / HV Induction motors IEC catalogue / Engineered motors EN 05-2006


HV Cast iron motors, HXR 6000 V - 50 Hz
Technical data for totally enclosed squirrel
cage three phase motors
IP 55 - IC 411 - Insulation class F, temperature rise class B
Efficiency Power factor Current Torque Sound
Full 3/4 Full 3/4 IN IS I0 TN TS Tmax Rotor Motor pressure
Output Motor Product Speed load load load load inertia weight level LP
kW type ID r/min 100% 75% 100% 75% A IN A Nm TN TN kgm2 kg dB(A)

1000 r/min = 6 poles 6000 V 50 Hz


125 HXR 355LB6 266 991 94.3 93.8 0.75 0.68 17 5.8 9 1205 1.2 2.3 5.7 1680 75
160 HXR 355LB6 267 990 94.7 94.5 0.77 0.72 21 5.7 10 1544 1.2 2.2 6.0 1720 75
180 HXR 355LB6 268 988 94.7 94.7 0.79 0.74 23 5.3 10 1739 1.2 2.0 6.0 1720 75
200 HXR 355LC6 269 989 94.9 94.9 0.79 0.74 26 5.5 12 1931 1.2 2.0 6.3 1770 75
224 HXR 355LD6 270 989 95.1 95.0 0.79 0.75 29 5.6 13 2163 1.3 2.1 6.9 1860 75
250 HXR 355LE6 271 989 95.2 95.2 0.80 0.76 31 5.6 14 2414 1.2 2.0 7.9 2000 75
280 HXR 400LC6 273 991 95.7 95.6 0.81 0.77 35 5.9 15 2698 1.0 2.2 11.2 2490 75
315 HXR 400LC6 274 991 95.8 95.8 0.82 0.78 38 5.8 15 3037 1.0 2.1 11.8 2560 75
355 HXR 400LD6 275 991 96.0 96.0 0.82 0.78 43 5.8 18 3421 1.0 2.1 12.8 2680 75
400 HXR 400LF6 276 992 96.2 96.2 0.82 0.77 49 5.9 20 3852 1.0 2.2 14.5 2870 75
450 HXR 400LJ6 277 992 96.4 96.4 0.83 0.79 54 6.0 21 4332 1.0 2.2 17.8 3250 75
450 HXR 450LD6 278 992 96.3 96.4 0.85 0.82 53 6.0 19 4330 1.0 2.1 28.1 3520 76
560 HXR 450LF6 279 993 96.6 96.7 0.86 0.83 65 6.0 21 5388 1.0 2.0 34.8 3920 76
630 HXR 450LH6 280 993 96.7 96.8 0.86 0.83 73 6.0 24 6060 1.0 2.0 38.8 4160 76
710 HXR 450LK6 281 994 96.9 96.9 0.84 0.81 84 6.3 30 6822 1.0 2.1 45.1 4520 76
800 HXR 500LH6 283 994 97.0 96.9 0.83 0.80 95 5.8 36 7685 0.8 2.1 58.9 5690 77
900
1000
1120
HXR 500LJ6
HXR 500LK6
HXR 500LN6
284
285
286
994
994
994
97.0
97.1
97.3
97.1
97.2
97.3
0.84
0.85
0.84
0.81
0.82
0.80
107 5.7
117 5.8
132 6.0
38
40
48
8647
9609
0.8
0.9
10755 0.9
2.0
2.0
2.1
62.8
68.7
80.0
5890
6180
6760
77
77
77
2
1250 HXR 500LR6 287 995 97.4 97.4 0.85 0.82 145 6.2 52 11995 0.8 2.2 92.1 7350 77
1400 HXR 560LM6 648 996 97.5 97.4 0.86 0.82 161 6.6 58 13424 0.8 2.4 133.8 9720 81
1600 HXR 560LR6 649 996 97.6 97.5 0.85 0.81 186 6.7 71 15334 0.7 2.5 160.3 10670 81
1800 HXR 560LU6 650 996 97.6 97.7 0.87 0.85 203 6.5 66 17260 0.8 2.4 203.3 12160 81

Data presented in rating lists are typical values.


Guaranteed values on request. All engineered motors
are optimized for the specified application. Accurate
motor data will be given on request at quotation phase.
Legally binding performance and specification data is
given to the end user once each order is confirmed.

ABB/ BU Machines / HV Induction motors IEC catalogue / Engineered motors EN 05-2006 71


HV Cast iron motors, HXR 6000 V - 50 Hz
Technical data for totally enclosed squirrel
cage three phase motors
IP 55 - IC 411 - Insulation class F, temperature rise class B

Efficiency Power factor Current Torque Sound


Full 3/4 Full 3/4 IN IS I0 TN TS Tmax Rotor Motor pressure
Output Motor Product Speed load load load load inertia weight level LP
kW type ID r/min 100% 75% 100% 75% A IN A Nm TN TN kgm2 kg dB(A)

750 r/min = 8 poles 6000 V 50 Hz


180 HXR 400LC8 377 741 94.4 94.4 0.77 0.72 24 4.7 11 2319 1.0 1.9 11.7 2520 75
200 HXR 400LD8 378 742 94.7 94.6 0.76 0.71 27 4.8 13 2575 1.0 1.9 12.7 2650 75
224 HXR 400LE8 379 741 94.8 94.9 0.78 0.74 29 4.8 13 2887 1.0 1.9 13.9 2780 75
250 HXR 400LF8 380 741 94.9 95.1 0.79 0.75 32 4.7 13 3224 1.0 1.8 15.0 2900 75
280 HXR 400LH8 381 741 95.2 95.3 0.79 0.75 36 4.8 15 3607 1.0 1.9 17.2 3150 75
315 HXR 400LJ8 382 741 95.2 95.2 0.78 0.74 41 4.8 18 4057 1.0 1.9 17.7 3220 75
355 HXR 450LD8 383 743 95.5 95.6 0.84 0.81 43 5.3 15 4565 0.9 2.0 30.0 3570 78
400 HXR 450LF8 384 743 95.8 95.8 0.83 0.80 48 5.4 18 5140 0.9 2.1 34.0 3810 78
450 HXR 450LG8 385 743 95.9 95.9 0.83 0.80 54 5.3 20 5783 0.9 2.1 36.7 3970 78
500 HXR 450LK8 386 744 96.1 96.1 0.84 0.80 60 5.6 22 6420 0.9 2.1 46.1 4530 78
560 HXR 450LM8 387 744 96.2 96.2 0.83 0.80 67 5.5 25 7190 0.9 2.0 51.4 4850 78
630 HXR 450LN8 388 745 96.4 96.2 0.81 0.76 77 6.2 34 8075 1.0 2.4 52.8 4930 78
710 HXR 500LJ8 389 745 96.3 96.2 0.83 0.80 85 5.9 33 9102 0.9 2.2 66.8 5970 78
800 HXR 500LK8 390 745 96.4 96.3 0.83 0.80 96 5.9 37 10257 0.9 2.2 68.8 6080 78
900 HXR 500LL8 391 745 96.4 96.4 0.84 0.80 107 5.7 40 11542 0.8 2.1 72.7 6270 78
1000 HXR 500LP8 392 745 96.6 96.5 0.84 0.80 119 5.9 45 12819 0.9 2.2 84.6 6860 78

2 1120
1250
1400
HXR 500LS8
HXR 560LM8
HXR 560LQ8
393
651
652
745
746
747
96.7
97.1
97.2
96.7
97.2
97.2
0.84
0.82
0.81
0.80
0.78
0.76
133 6.0
151 5.5
172 6.4
50
59
76
14352 0.9
16002 0.8
17907 0.9
2.3
2.0
2.4
104.5
136.3
157.4
7830
9700
10390
78
80
80
1600 HXR 560LU8 653 747 97.4 97.2 0.79 0.74 199 6.3 93 20454 0.8 2.4 205.0 12110 80

Data presented in rating lists are typical values.


Guaranteed values on request. All engineered motors
are optimized for the specified application. Accurate
motor data will be given on request at quotation phase.
Legally binding performance and specification data is
given to the end user once each order is confirmed.

72 ABB/ BU Machines / HV Induction motors IEC catalogue / Engineered motors EN 05-2006


HV Cast iron motors, HXR 6000 V - 50 Hz
Technical data for totally enclosed squirrel
cage three phase motors
IP 55 - IC 411 - Insulation class F, temperature rise class B
Efficiency Power factor Current Torque Sound
Full 3/4 Full 3/4 IN IS I0 TN TS Tmax Rotor Motor pressure
Output Motor Product Speed load load load load inertia weight level LP
kW type ID r/min 100% 75% 100% 75% A IN A Nm TN TN kgm2 kg dB(A)

600 r/min = 10 poles 6000 V 50 Hz


224 HXR 400LH10 471 595 94.5 94.2 0.71 0.65 32 5.1 18 3597 1.1 2.1 25.3 3170 75
250 HXR 450LE10 472 595 95.2 95.2 0.75 0.69 34 5.2 17 4014 1.0 2.1 32.7 3710 75
280 HXR 450LF10 473 595 95.3 95.4 0.76 0.70 37 5.1 19 4497 1.0 2.0 35.4 3860 75
315 HXR 450LG10 474 595 95.5 95.5 0.76 0.70 42 5.2 21 5059 1.0 2.0 38.1 4030 75
355 HXR 450LJ10 475 594 95.6 95.7 0.77 0.72 46 5.1 22 5703 1.0 2.0 43.6 4340 75
400 HXR 450LK10 476 595 95.7 95.7 0.76 0.70 53 5.3 26 6422 1.0 2.1 46.3 4500 75
450 HXR 450LM10 477 595 95.8 95.8 0.75 0.69 60 5.3 30 7222 1.0 2.1 51.6 4820 75
500 HXR 500LJ10 479 594 96.2 96.3 0.78 0.73 64 5.0 28 8038 1.0 1.9 64.3 5890 76
560 HXR 500LL10 480 594 96.3 96.4 0.78 0.74 71 5.0 31 9001 1.0 1.9 74.2 6370 76
630 HXR 500LM10 481 595 96.3 96.3 0.79 0.74 80 5.1 35 10116 0.9 2.0 78.5 6540 76
710 HXR 500LP10 482 595 96.3 96.4 0.79 0.75 89 5.0 37 11404 0.9 1.9 84.5 6830 76
800 HXR 500LQ10 483 594 96.4 96.5 0.80 0.76 100 4.9 41 12852 0.9 1.9 90.5 7120 76
900 HXR 500LS10 484 596 96.4 96.3 0.75 0.69 120 5.3 60 14414 1.0 2.0 100.7 7610 76
1000 HXR 560LN10 654 597 96.9 96.8 0.78 0.73 128 5.0 57 16006 0.7 1.9 144.8 9910 78
1120 HXR 560LR10 655 597 97.0 96.8 0.75 0.69 147 5.7 74 17910 0.8 2.2 173.2 10900 78
1250 HXR 560LU10 656 597 97.0 96.9 0.77 0.72 161 5.6 77 19991 0.8 2.1 208.7 12070 78

500 r/min = 12 poles


140 HXR 400LF12 556 494 93.1 92.8
6000 V 50 Hz
0.68 0.60 21 4.3 13 2704 1.0 1.9 21.0 2840 75
2
160 HXR 400LG12 557 494 93.0 92.7 0.68 0.61 24 4.3 15 3090 1.0 1.9 22.7 2970 75
180 HXR 400LJ12 558 496 93.3 92.7 0.65 0.57 29 4.7 19 3469 1.1 2.1 26.1 3200 75
224 HXR 450LG12 560 495 94.4 94.2 0.71 0.65 32 4.3 17 4324 0.9 1.8 38.2 4040 75
200 HXR 450LH12 559 495 94.3 94.1 0.70 0.64 29 4.2 16 3861 0.9 1.8 34.1 3810 75
250 HXR 450LJ12 561 495 94.6 94.4 0.71 0.64 36 4.2 19 4824 0.8 1.8 43.6 4360 75
280 HXR 450LK12 562 495 94.6 94.5 0.71 0.65 40 4.3 21 5405 0.9 1.8 46.3 4520 75
315 HXR 450LL12 563 495 94.7 94.6 0.71 0.66 45 4.2 23 6081 0.9 1.8 49.1 4680 75
355 HXR 500LJ12 565 495 95.1 94.8 0.71 0.65 50 4.5 27 6851 0.9 1.9 64.3 5890 75
400 HXR 500LK12 566 495 95.0 94.8 0.71 0.65 57 4.5 30 7720 0.9 1.8 68.3 6080 75
450 HXR 500LL12 567 495 95.1 94.9 0.72 0.66 63 4.4 33 8687 0.9 1.8 74.3 6380 75
500 HXR 500LN12 568 495 95.3 95.1 0.72 0.66 70 4.5 36 9651 0.9 1.8 82.2 6770 75
560 HXR 500LQ12 569 495 95.3 95.1 0.71 0.66 79 4.4 41 10806 0.9 1.8 90.1 7160 75
630 HXR 500LS12 570 495 95.4 95.2 0.71 0.65 89 4.5 47 12153 0.9 1.8 102.0 7740 75
710 HXR 560LM12 657 496 96.3 96.3 0.77 0.72 92 4.6 42 13669 0.7 1.9 136.9 9600 76
800 HXR 560LP12 658 496 96.4 96.3 0.75 0.69 106 5.1 54 15387 0.8 2.2 151.0 10060 76
900 HXR 560LS12 659 497 96.5 96.5 0.76 0.70 118 5.2 60 17308 0.8 2.2 179.3 11060 76
1000 HXR 560LU12 660 497 96.7 96.6 0.77 0.72 130 4.8 60 19215 0.8 1.9 208.9 12020 76

Data presented in rating lists are typical values.


Guaranteed values on request. All engineered motors
are optimized for the specified application. Accurate
motor data will be given on request at quotation phase.
Legally binding performance and specification data is
given to the end user once each order is confirmed.

ABB/ BU Machines / HV Induction motors IEC catalogue / Engineered motors EN 05-2006 73


HV Cast iron motors, HXR 10000 V - 50 Hz
Technical data for totally enclosed squirrel
cage three phase motors
IP 55 - IC 411 - Insulation class F, temperature rise class B

Efficiency Power factor Current Torque Sound


Full 3/4 Full 3/4 IN IS I0 TN TS Tmax Rotor Motor pressure
Output Motor Product Speed load load load load inertia weight level LP
kW type ID r/min 100% 75% 100% 75% A IN A Nm TN TN kgm2 kg dB(A)

3000 r/min = 2 poles 10000 V 50 Hz


400 HXR 450LE2 16 2984 95.6 95.2 0.89 0.87 27 6.3 8 1280 0.5 2.6 10.7 3670 85
450 HXR 450LF2 17 2984 95.8 95.5 0.89 0.87 30 6.3 8 1440 0.5 2.5 11.9 3870 85
500 HXR 450LG2 18 2984 96.0 95.8 0.90 0.89 33 6.4 8 1600 0.5 2.6 12.5 4010 85
560 HXR 500LF2 19 2987 96.0 95.6 0.90 0.88 38 6.3 10 1790 0.5 2.6 20.6 5300 86
630 HXR 500LG2 20 2986 96.2 95.9 0.91 0.90 41 6.4 10 2014 0.5 2.6 22.7 5570 86
710 HXR 500LJ2 21 2987 96.4 96.2 0.91 0.89 47 6.4 11 2269 0.5 2.6 24.6 5850 86
800 HXR 500LL2 22 2988 96.7 96.5 0.92 0.91 52 6.4 11 2557 0.5 2.5 27.5 6300 86
900 HXR 500LM2 23 2989 96.8 96.6 0.90 0.88 60 6.7 15 2876 0.5 2.6 29.2 6490 86
1120 HXR 560LN2 711 2990 97.0 96.7 0.90 0.89 74 6.9 19 3577 0.5 2.8 45.8 9690 87
1250 HXR 560LQ2 712 2990 97.1 96.9 0.91 0.89 82 6.9 21 3993 0.5 2.7 52.3 10400 87

1500 r/min = 4 poles 10000 V 50 Hz


355 HXR 450LC4 120 1492 95.8 95.5 0.84 0.80 26 6.4 10 2272 0.8 2.4 16.2 3470 77
400 HXR 450LD4 121 1492 96.0 95.8 0.85 0.81 28 6.4 10 2560 0.8 2.3 17.9 3630 77
450 HXR 450LE4 122 1492 96.2 96.1 0.85 0.82 32 6.3 11 2881 0.8 2.3 19.5 3790 77
500 HXR 450LF4 123 1492 96.4 96.2 0.85 0.82 35 6.3 12 3200 0.8 2.2 21.0 3950 77
560 HXR 450LG4 124 1492 96.5 96.4 0.85 0.82 39 6.3 14 3584 0.8 2.2 22.5 4100 77

2 630
710
HXR 450LH4
HXR 500LF4
125
126
1493
1491
96.7
96.6
96.5
96.5
0.84
0.86
0.81
0.83
45
50
6.5 17
5.5 16
4030
4548
0.8
0.7
2.2
2.0
24.0
36.2
4260
5460
77
77
800 HXR 500LG4 127 1492 96.8 96.8 0.87 0.85 55 5.9 17 5120 0.7 2.2 39.2 5660 77
900 HXR 500LK4 128 1493 97.0 97.0 0.87 0.85 61 6.2 19 5758 0.8 2.3 46.6 6240 77
1000 HXR 500LL4 129 1493 97.1 97.1 0.87 0.84 69 6.1 22 6397 0.7 2.2 48.8 6430 77
1120 HXR 560LL4 661 1494 97.4 97.3 0.87 0.84 76 6.4 25 7159 0.7 2.4 71.4 9530 82
1250 HXR 560LN4 662 1495 97.4 97.4 0.87 0.84 85 6.7 29 7985 0.6 2.6 78.6 9950 82
1400 HXR 560LR4 663 1495 97.6 97.5 0.87 0.84 95 6.8 33 8942 0.6 2.7 87.3 10560 82

Data presented in rating lists are typical values.


Guaranteed values on request. All engineered motors
are optimized for the specified application. Accurate
motor data will be given on request at quotation phase.
Legally binding performance and specification data is
given to the end user once each order is confirmed.

74 ABB/ BU Machines / HV Induction motors IEC catalogue / Engineered motors EN 05-2006


HV Cast iron motors, HXR 10000 V - 50 Hz
Technical data for totally enclosed squirrel
cage three phase motors
IP 55 - IC 411 - Insulation class F, temperature rise class B
Efficiency Power factor Current Torque Sound
Full 3/4 Full 3/4 IN IS I0 TN TS Tmax Rotor Motor pressure
Output Motor Product Speed load load load load inertia weight level LP
kW type ID r/min 100% 75% 100% 75% A IN A Nm TN TN kgm2 kg dB(A)

1000 r/min = 6 poles 10000 V 50 Hz


315 HXR 450LD6 233 993 95.5 95.3 0.80 0.76 24 5.7 10 3030 0.9 2.2 18.9 3610 76
355 HXR 450LE6 234 992 95.7 95.6 0.82 0.77 26 5.7 11 3416 0.9 2.2 20.6 3770 76
400 HXR 450LF6 235 993 96.0 95.9 0.82 0.78 29 5.8 12 3845 0.8 2.2 22.4 3930 76
450 HXR 450LJ6 236 994 96.2 96.0 0.81 0.76 33 6.1 15 4322 0.8 2.3 26.4 4330 76
500 HXR 450LK6 237 994 96.3 96.0 0.80 0.75 37 6.3 17 4801 0.9 2.4 28.8 4540 76
560 HXR 500LF6 238 995 96.4 96.3 0.82 0.77 41 6.2 18 5375 0.8 2.4 40.9 5420 77
630 HXR 500LG6 239 995 96.6 96.5 0.82 0.78 46 6.0 19 6048 0.8 2.3 43.8 5610 77
710 HXR 500LH6 240 995 96.7 96.6 0.83 0.79 51 6.0 20 6817 0.8 2.2 46.7 5800 77
800 HXR 500LL6 241 995 96.9 96.8 0.82 0.77 58 6.3 25 7676 0.9 2.4 53.8 6280 77
900 HXR 500LM6 242 995 97.0 96.9 0.81 0.76 66 6.1 29 8635 0.8 2.3 57.8 6560 77
1000 HXR 560LL6 664 996 97.2 97.1 0.84 0.79 71 6.1 28 9588 0.7 2.5 94.1 9480 81
1120 HXR 560LN6 665 996 97.3 97.2 0.84 0.79 79 6.4 32 10737 0.7 2.5 104.1 9960 81
1250 HXR 560LQ6 666 996 97.3 97.2 0.82 0.78 90 6.3 38 11980 0.7 2.6 113.3 10380 81
1400 HXR 560LR6 667 997 97.4 97.2 0.79 0.72 106 6.8 53 13410 0.7 2.8 117.5 10620 81

750 r/min = 8 poles 10000 V 50 Hz


315 HXR 500LC8 350 744 94.7 94.4 0.78 0.73 25 5.6 12 4040 0.8 2.3 32.5 4820 78
355
400
HXR 500LE8
HXR 500LF8
351
352
745
745
94.9
95.2
94.6
94.9
0.78
0.78
0.73
0.72
28
31
5.7 13
5.7 15
4552
5128
0.9
0.9
2.3
2.3
36.9
39.8
5090
5290
78
78
2
450 HXR 500LG8 353 745 95.5 95.2 0.78 0.72 35 5.8 17 5767 0.9 2.4 44.1 5580 78
500 HXR 500LH8 354 745 95.7 95.4 0.79 0.73 38 5.8 18 6409 0.9 2.3 47.1 5770 78
560 HXR 500LJ8 355 745 95.8 95.6 0.80 0.74 42 5.8 19 7180 0.9 2.3 50.1 5960 78
630 HXR 500LK8 356 745 96.0 95.8 0.80 0.75 48 5.7 22 8078 0.9 2.2 53.0 6160 78
710 HXR 500LM8 357 745 96.1 96.0 0.80 0.76 53 5.6 23 9105 0.9 2.2 57.5 6440 78
800 HXR 500LP8 358 744 96.2 96.2 0.81 0.77 59 5.5 25 10261 0.9 2.1 63.3 6830 78
900 HXR 560LM8 668 746 96.7 96.6 0.77 0.72 70 5.4 33 11519 0.8 2.2 97.4 9570 80
1000 HXR 560LN8 669 747 96.9 96.8 0.76 0.70 78 5.7 40 12789 0.7 2.3 105.5 9940 80
1120 HXR 560LR8 670 746 97.0 96.9 0.78 0.72 86 5.6 41 14332 0.8 2.2 120.2 10660 80

600 r/min = 10 poles 10000 V 50 Hz


560 HXR 560LL10 671 597 95.6 95.3 0.71 0.64 48 5.0 27 8959 0.8 2.1 95.3 9390 78
630 HXR 560LN10 672 596 95.7 95.5 0.72 0.65 53 5.2 29 10086 0.9 2.1 105.4 9870 78
710 HXR 560LR10 673 597 96.0 95.7 0.71 0.65 60 5.0 33 11359 0.8 2.1 118.0 10480 78

Data presented in rating lists are typical values.


Guaranteed values on request. All engineered motors
are optimized for the specified application. Accurate
motor data will be given on request at quotation phase.
Legally binding performance and specification data is
given to the end user once each order is confirmed.

ABB/ BU Machines / HV Induction motors IEC catalogue / Engineered motors EN 05-2006 75


HV Modular motors 3000 V - 50 Hz
Technical data for totally enclosed squirrel
cage three phase motors
IP 55 - IC 611 - Insulation class F, temperature rise class B

Efficiency Power factor Current Torque Sound


Full 3/4 Full 3/4 IN IS I0 TN TS Tmax Rotor Motor pressure
Output Motor Product Speed load load load load inertia weight level LP
kW type ID r/min 100% 75% 100% 75% A IN A Nm TN TN kgm2 kg dB(A)

3000 r/min = 2 poles 3000 V 50 Hz


630 AMA 400L2A 1079 2977 95.3 95.1 0.86 0.84 149 5.1 43 2021 0.5 2.2 7.0 3000 85
710 AMA 400L2A 1080 2977 95.6 95.5 0.86 0.84 166 5.2 45 2277 0.6 2.2 7.5 3130 85
800 AMA 400L2A 1081 2977 95.7 95.7 0.87 0.86 184 5.3 47 2566 0.6 2.2 8.0 3220 85
900 AMA 400L2A 1082 2977 96.0 96.0 0.87 0.86 207 5.3 52 2886 0.6 2.2 8.4 3340 85
1000 AMA 400L2A 1083 2979 96.2 96.2 0.87 0.85 231 5.6 61 3206 0.6 2.3 8.9 3450 85
1120 AMA 450L2A 1084 2979 96.2 96.1 0.86 0.85 260 4.9 69 3590 0.5 2.1 11.6 4270 86
1250 AMA 450L2A 1085 2980 96.4 96.3 0.84 0.83 296 5.0 84 4005 0.5 2.1 12.3 4420 86
1400 AMA 450L2A 1086 2982 96.6 96.5 0.84 0.82 331 5.1 93 4484 0.5 2.2 13.8 4710 86
1600 AMA 500L2A 1087 2983 96.5 96.5 0.89 0.88 358 4.9 80 5122 0.4 2.0 21.0 5370 87
1800 AMA 500L2A 1088 2986 96.7 96.6 0.87 0.86 409 5.3 113 5757 0.4 2.2 22.3 5520 87
2000 AMA 500L2A 1089 2983 96.8 96.8 0.90 0.89 444 4.9 94 6402 0.4 2.0 23.6 5710 87
2240 AMA 500L2A 1162 2986 97.0 97.0 0.88 0.87 505 5.3 128 7164 0.4 2.2 26.2 6090 87

1500 r/min = 4 poles 3000 V 50 Hz


630 AMA 400L4A 1090 1486 95.3 95.3 0.88 0.86 145 4.8 41 4049 0.6 1.9 15.4 3050 79
710 AMA 400L4A 1091 1488 95.6 95.6 0.86 0.83 166 5.5 56 4558 0.7 2.3 16.4 3150 79
800 AMA 400L4A 1092 1487 95.7 95.7 0.86 0.84 186 5.4 60 5136 0.7 2.2 17.4 3220 79

2 900
1000
AMA 400L4A
AMA 400L4A
1093
1094
1487
1488
95.9
96.1
95.9
96.1
0.86
0.87
0.83
0.84
210
231
5.4 69
5.7 75
5778
6417
0.7
0.7
2.2
2.3
18.3
20.2
3330
3520
79
79
1120 AMA 400L4A 1095 1487 96.1 96.2 0.87 0.85 257 5.3 75 7191 0.7 2.1 21.0 3550 79
1250 AMA 450L4A 1096 1488 96.0 96.0 0.87 0.85 288 5.4 85 8023 0.7 2.1 31.2 4210 81
1400 AMA 450L4A 1097 1488 96.2 96.3 0.88 0.86 318 5.5 87 8984 0.7 2.1 34.5 4470 81
1600 AMA 450L4A 1098 1488 96.4 96.5 0.88 0.86 364 5.6 102 10265 0.7 2.1 37.8 4720 81
1800 AMA 500L4A 1099 1491 96.3 96.3 0.89 0.87 406 5.4 106 11531 0.7 2.0 55.1 5570 82
2000 AMA 500L4A 1100 1491 96.5 96.5 0.88 0.87 453 5.4 121 12811 0.7 2.0 57.9 5730 82
2240 AMA 500L4A 1101 1491 96.6 96.6 0.88 0.87 506 5.6 135 14344 0.7 2.1 63.6 6030 82
2500 AMA 500L4A 1163 1490 96.7 96.8 0.89 0.89 556 5.5 125 16024 0.8 2.0 69.1 6380 82

Data presented in rating lists are typical values.


Guaranteed values on request. All engineered motors
are optimized for the specified application. Accurate
motor data will be given on request at quotation phase.
Legally binding performance and specification data is
given to the end user once each order is confirmed.

76 ABB/ BU Machines / HV Induction motors IEC catalogue / Engineered motors EN 05-2006


HV Modular motors 3000 V - 50 Hz
Technical data for totally enclosed squirrel
cage three phase motors
IP 55 - IC 611 - Insulation class F, temperature rise class B
Efficiency Power factor Current Torque Sound
Full 3/4 Full 3/4 IN IS I0 TN TS Tmax Rotor Motor pressure
Output Motor Product Speed load load load load inertia weight level LP
kW type ID r/min 100% 75% 100% 75% A IN A Nm TN TN kgm2 kg dB(A)

1000 r/min = 6 poles 3000 V 50 Hz


450 AMA 400L6A 1102 988 95.0 95.2 0.84 0.81 109 4.9 40 4350 0.7 1.9 16.8 2950 78
500 AMA 400L6A 1103 989 95.2 95.3 0.81 0.77 124 4.8 51 4829 0.7 1.9 17.9 3050 78
560 AMA 400L6A 1104 988 95.2 95.4 0.83 0.80 136 4.9 51 5411 0.7 1.8 19.1 3130 78
630 AMA 400L6A 1105 990 95.5 95.6 0.82 0.78 155 5.0 62 6080 0.7 1.9 21.4 3320 78
710 AMA 400L6A 1106 990 95.6 95.7 0.81 0.77 176 5.1 73 6851 0.8 1.9 22.6 3410 78
800 AMA 400L6A 1107 990 95.8 95.9 0.83 0.79 194 5.2 74 7720 0.8 1.9 24.9 3600 78
900 AMA 450L6A 1108 991 96.0 96.2 0.86 0.83 210 5.1 68 8670 0.6 1.9 39.2 4220 79
1000 AMA 450L6A 1109 992 96.2 96.3 0.85 0.82 236 5.3 82 9629 0.7 2.0 41.3 4340 79
1120 AMA 450L6A 1110 991 96.1 96.3 0.86 0.84 260 5.3 80 10792 0.7 2.0 43.7 4450 79
1250 AMA 450L6A 1111 992 96.4 96.5 0.84 0.81 296 5.4 104 12033 0.7 2.0 47.8 4700 79
1400 AMA 500L6A 1112 992 96.5 96.6 0.87 0.85 320 5.4 95 13475 0.7 2.0 67.4 5560 79
1600 AMA 500L6A 1113 993 96.6 96.7 0.87 0.84 368 5.6 115 15393 0.7 2.0 74.3 5850 79
1800 AMA 500L6A 1164 992 96.6 96.8 0.88 0.87 406 5.3 106 17328 0.7 1.9 81.5 6140 79
2000 AMA 500L6A 1165 993 96.8 96.9 0.86 0.84 462 5.7 149 19226 0.7 2.1 89.4 6450 79

750 r/min = 8 poles 3000 V 50 Hz


280 AMA 400L8A 1114 740 94.7 94.8 0.82 0.78 69 5.1 28 3611 0.9 2.1 18.7 2920 77
315
355
AMA 400L8A
AMA 400L8A
1115
1116
740
741
94.7
95.0
94.9
95.1
0.84
0.83
0.80
0.79
77
87
4.7 28
5.2 35
4067
4577
0.8
0.9
1.9
2.1
20.1
21.5
3000
3100
77
77
2
400 AMA 400L8A 1117 740 95.1 95.3 0.83 0.79 97 5.0 37 5159 0.9 2.0 22.9 3200 77
450 AMA 400L8A 1118 740 95.1 95.3 0.83 0.80 109 5.0 41 5804 0.9 2.0 24.3 3290 77
500 AMA 400L8A 1119 741 95.2 95.4 0.83 0.79 122 5.1 47 6447 0.9 2.0 25.7 3380 77
560 AMA 400L8A 1120 740 95.3 95.5 0.84 0.80 135 5.0 50 7222 0.9 2.0 28.4 3570 77
630 AMA 450L8A 1121 743 95.7 95.8 0.81 0.77 156 5.4 66 8097 0.8 2.1 42.0 4050 77
710 AMA 450L8A 1122 742 95.9 96.1 0.85 0.82 168 5.2 58 9136 0.8 2.0 47.4 4300 77
800 AMA 450L8A 1123 742 96.0 96.2 0.85 0.83 188 5.2 63 10293 0.8 2.0 52.6 4540 77
900 AMA 450L8A 1124 743 96.2 96.3 0.85 0.82 212 5.5 74 11573 0.8 2.1 57.9 4790 77
1000 AMA 500L8A 1125 742 96.1 96.4 0.87 0.85 231 4.9 67 12870 0.7 1.8 78.1 5500 77
1120 AMA 500L8A 1126 743 96.4 96.6 0.87 0.84 258 5.2 79 14394 0.7 1.9 87.3 5810 77
1250 AMA 500L8A 1127 743 96.4 96.6 0.86 0.83 291 5.3 96 16065 0.7 2.0 94.9 6080 77
1400 AMA 500L8A 1166 743 96.4 96.7 0.86 0.84 323 5.4 101 17998 0.8 2.0 103.8 6380 77

Data presented in rating lists are typical values.


Guaranteed values on request. All engineered motors
are optimized for the specified application. Accurate
motor data will be given on request at quotation phase.
Legally binding performance and specification data is
given to the end user once each order is confirmed.

ABB/ BU Machines / HV Induction motors IEC catalogue / Engineered motors EN 05-2006 77


HV Modular motors 3000 V - 50 Hz
Technical data for totally enclosed squirrel
cage three phase motors
IP 55 - IC 611 - Insulation class F, temperature rise class B

Efficiency Power factor Current Torque Sound


Full 3/4 Full 3/4 IN IS I0 TN TS Tmax Rotor Motor pressure
Output Motor Product Speed load load load load inertia weight level LP
kW type ID r/min 100% 75% 100% 75% A IN A Nm TN TN kgm2 kg dB(A)

600 r/min = 10 poles 3000 V 50 Hz


200 AMA 400L10A 1128 592 93.6 93.5 0.73 0.67 56 4.3 30 3227 0.7 2.0 17.4 2820 76
224 AMA 400L10A 1129 592 93.8 93.8 0.75 0.69 62 4.2 31 3615 0.7 1.9 18.8 2920 76
250 AMA 400L10A 1130 592 94.0 94.0 0.75 0.70 68 4.2 34 4035 0.7 1.9 20.2 3020 76
280 AMA 400L10A 1131 592 94.1 94.1 0.75 0.69 76 4.3 38 4518 0.7 1.9 21.6 3110 76
315 AMA 400L10A 1132 593 94.3 94.2 0.73 0.67 88 4.6 46 5071 0.8 2.0 24.4 3290 76
355 AMA 400L10A 1133 593 94.5 94.5 0.74 0.69 97 4.5 49 5719 0.8 1.9 25.8 3400 76
400 AMA 400L10A 1134 593 94.7 94.5 0.73 0.67 111 4.7 60 6437 0.9 2.1 28.6 3590 76
450 AMA 450L10A 1135 592 94.9 95.1 0.81 0.77 112 4.6 45 7254 0.8 1.9 41.9 4040 76
500 AMA 450L10A 1136 593 95.0 95.2 0.81 0.77 125 4.8 53 8056 0.8 2.0 44.5 4160 76
560 AMA 450L10A 1137 593 95.2 95.4 0.81 0.77 139 4.8 57 9021 0.8 2.0 49.7 4400 76
630 AMA 450L10A 1138 593 95.3 95.5 0.82 0.79 155 4.7 60 10149 0.8 2.0 57.5 4770 76
710 AMA 500L10A 1139 595 95.8 95.8 0.80 0.75 177 5.4 79 11397 0.8 2.2 78.6 5450 76
800 AMA 500L10A 1140 595 95.9 95.9 0.81 0.77 197 5.1 82 12849 0.7 2.1 83.0 5600 76
900 AMA 500L10A 1141 594 96.0 96.1 0.83 0.80 217 5.3 84 14457 0.8 2.1 96.4 6060 76
1000 AMA 500L10A 1167 594 96.0 96.2 0.84 0.81 238 5.0 84 16073 0.7 2.0 105.1 6350 76

500 r/min = 12 poles 3000 V 50 Hz

2 140
160
AMA 400L12A 1142
AMA 400L12A 1143
493
493
92.6
92.8
92.2
92.5
0.70
0.71
0.63
0.65
42
46
4.2 24
4.0 25
2711
3100
0.8
0.8
2.0
1.9
18.8
20.2
2910
3010
76
76
180 AMA 400L12A 1144 493 92.9 92.7 0.72 0.66 52 4.0 28 3488 0.8 1.9 21.6 3100 76
200 AMA 400L12A 1145 493 93.1 92.8 0.71 0.65 58 4.1 32 3874 0.8 1.9 23.0 3200 76
224 AMA 400L12A 1146 493 93.2 92.9 0.70 0.63 66 4.2 38 4335 0.9 2.0 24.4 3300 76
250 AMA 400L12A 1147 493 93.2 92.9 0.71 0.65 73 4.1 40 4841 0.8 1.9 25.8 3370 76
280 AMA 400L12A 1148 494 93.3 93.0 0.70 0.63 82 4.3 47 5418 0.9 2.0 28.6 3560 76
315 AMA 450L12A 1149 495 94.5 94.3 0.71 0.64 90 4.6 51 6083 0.8 2.1 42.0 4020 76
355 AMA 450L12A 1150 495 94.6 94.4 0.71 0.64 102 4.6 58 6855 0.8 2.1 44.6 4150 76
400 AMA 450L12A 1151 494 94.7 94.6 0.73 0.66 112 4.5 60 7726 0.8 2.0 49.8 4380 76
450 AMA 450L12A 1152 494 94.6 94.6 0.74 0.68 123 4.3 63 8699 0.8 1.9 52.4 4480 76
500 AMA 450L12A 1153 494 94.8 94.7 0.74 0.67 138 4.4 73 9660 0.8 2.0 57.7 4720 76
560 AMA 500L12A 1154 494 95.1 95.2 0.76 0.71 148 4.3 70 10817 0.7 1.9 78.3 5450 76
630 AMA 500L12A 1155 495 95.3 95.3 0.76 0.71 166 4.4 78 12166 0.7 1.9 87.0 5750 76
710 AMA 500L12A 1156 494 95.4 95.5 0.77 0.72 186 4.3 85 13717 0.7 1.8 91.3 5930 76
800 AMA 500L12A 1169 495 95.5 95.5 0.77 0.72 210 4.4 99 15445 0.7 1.9 104.4 6360 76

Data presented in rating lists are typical values.


Guaranteed values on request. All engineered motors
are optimized for the specified application. Accurate
motor data will be given on request at quotation phase.
Legally binding performance and specification data is
given to the end user once each order is confirmed.

78 ABB/ BU Machines / HV Induction motors IEC catalogue / Engineered motors EN 05-2006


HV Modular motors 6000 V - 50 Hz
Technical data for totally enclosed squirrel
cage three phase motors
IP 55 - IC 611 - Insulation class F, temperature rise class B
Efficiency Power factor Current Torque Sound
Full 3/4 Full 3/4 IN IS I0 TN TS Tmax Rotor Motor pressure
Output Motor Product Speed load load load load inertia weight level LP
kW type ID r/min 100% 75% 100% 75% A IN A Nm TN TN kgm2 kg dB(A)

3000 r/min = 2 poles 6000 V 50 Hz


630 AMA 400L2A 79 2977 95.0 94.9 0.86 0.84 74 5.1 21 2021 0.5 2.2 7.0 2960 85
710 AMA 400L2A 80 2977 95.3 95.3 0.86 0.85 83 5.2 23 2277 0.5 2.2 7.5 3070 85
800 AMA 400L2A 81 2977 95.6 95.6 0.87 0.86 92 5.3 24 2566 0.6 2.2 8.0 3190 85
900 AMA 400L2A 82 2977 95.8 95.8 0.87 0.86 104 5.3 26 2887 0.6 2.2 8.4 3300 85
1000 AMA 400L2A 83 2979 96.0 96.0 0.87 0.85 115 5.5 31 3206 0.6 2.3 8.9 3410 85
1120 AMA 450L2A 84 2979 96.1 96.0 0.86 0.85 130 5.0 35 3590 0.5 2.1 11.6 4220 86
1250 AMA 450L2A 85 2980 96.3 96.2 0.84 0.82 149 5.0 43 4005 0.5 2.1 12.3 4350 86
1400 AMA 450L2A 86 2982 96.5 96.4 0.84 0.82 166 5.1 47 4484 0.5 2.2 13.8 4650 86
1600 AMA 500L2A 87 2985 96.4 96.3 0.87 0.85 184 5.3 52 5118 0.4 2.2 20.9 5250 87
1800 AMA 500L2A 88 2986 96.6 96.5 0.88 0.86 205 5.4 56 5757 0.4 2.2 22.3 5460 87
2000 AMA 500L2A 89 2986 96.8 96.7 0.87 0.85 228 5.4 64 6396 0.4 2.2 23.6 5640 87
2240 AMA 500L2A 477 2986 96.9 96.9 0.88 0.87 252 5.4 64 7164 0.5 2.2 26.2 6010 87

1500 r/min = 4 poles 6000 V 50 Hz


630 AMA 400L4A 90 1486 95.0 95.1 0.88 0.86 73 4.8 21 4049 0.6 1.9 15.4 2990 79
710 AMA 400L4A 91 1487 95.3 95.4 0.86 0.83 84 5.4 29 4558 0.7 2.2 16.3 3080 79
800 AMA 400L4A 92 1487 95.5 95.6 0.86 0.84 93 5.3 31 5136 0.7 2.1 17.3 3180 79
900
1000
AMA 400L4A
AMA 400L4A
93
94
1487
1488
95.7
95.9
95.8
95.9
0.86
0.85
0.83
0.82
105 5.4 34
118 5.6 42
5778
6417
0.7
0.7
2.2
2.3
18.3
19.3
3280
3380
79
79
2
1250 AMA 450L4A 96 1488 95.9 95.9 0.87 0.85 144 5.5 43 8023 0.7 2.1 31.1 4150 81
1400 AMA 450L4A 97 1488 96.1 96.2 0.88 0.86 160 5.4 45 8985 0.7 2.0 34.4 4410 81
1600 AMA 500L4A 98 1491 96.0 96.0 0.88 0.87 181 5.5 49 10249 0.7 2.0 52.1 5310 82
1800 AMA 500L4A 99 1491 96.2 96.2 0.89 0.87 203 5.5 53 11531 0.7 2.0 55.0 5470 82
2000 AMA 500L4A 100 1491 96.3 96.4 0.88 0.86 227 5.5 62 12811 0.7 2.0 57.7 5630 82
2240 AMA 500L4A 101 1491 96.5 96.6 0.88 0.86 255 5.6 70 14344 0.7 2.1 63.2 5950 82
2500 AMA 500L4A 479 1490 96.6 96.7 0.88 0.86 284 5.5 75 16020 0.8 2.0 66.0 6130 82

Data presented in rating lists are typical values.


Guaranteed values on request. All engineered motors
are optimized for the specified application. Accurate
motor data will be given on request at quotation phase.
Legally binding performance and specification data is
given to the end user once each order is confirmed.

ABB/ BU Machines / HV Induction motors IEC catalogue / Engineered motors EN 05-2006 79


HV Modular motors 6000 V - 50 Hz
Technical data for totally enclosed squirrel
cage three phase motors
IP 55 - IC 611 - Insulation class F, temperature rise class B

Efficiency Power factor Current Torque Sound


Full 3/4 Full 3/4 IN IS I0 TN TS Tmax Rotor Motor pressure
Output Motor Product Speed load load load load inertia weight level LP
kW type ID r/min 100% 75% 100% 75% A IN A Nm TN TN kgm2 kg dB(A)

1000 r/min = 6 poles 6000 V 50 Hz


450 AMA 400L6A 102 988 94.7 94.9 0.84 0.81 54 4.9 20 4351 0.8 1.9 16.8 2900 78
500 AMA 400L6A 103 989 94.9 95.0 0.82 0.78 62 4.9 25 4829 0.7 1.9 17.9 2980 78
560 AMA 400L6A 104 988 95.0 95.2 0.83 0.80 68 5.0 25 5411 0.8 1.9 19.1 3070 78
630 AMA 400L6A 105 990 95.3 95.4 0.82 0.78 77 5.1 31 6080 0.7 1.9 21.4 3260 78
710 AMA 400L6A 106 990 95.4 95.5 0.81 0.77 88 5.1 36 6851 0.8 2.0 22.6 3360 78
800 AMA 450L6A 107 991 95.7 95.9 0.86 0.84 93 5.2 30 7707 0.6 1.9 37.1 4030 79
900 AMA 450L6A 108 991 95.9 96.0 0.86 0.84 105 5.2 34 8670 0.6 2.0 39.2 4160 79
1000 AMA 450L6A 109 992 96.1 96.2 0.85 0.82 118 5.4 41 9629 0.7 2.0 41.3 4290 79
1125 AMA 450L6A 110 991 96.0 96.3 0.86 0.84 131 5.3 40 10840 0.7 2.0 43.7 4400 79
1250 AMA 450L6A 111 993 96.3 96.4 0.82 0.78 152 5.8 62 12024 0.8 2.2 47.8 4670 79
1400 AMA 500L6A 112 992 96.3 96.4 0.87 0.85 161 5.4 48 13475 0.7 2.0 67.2 5450 79
1600 AMA 500L6A 113 992 96.4 96.6 0.88 0.86 182 5.4 51 15401 0.7 1.9 74.3 5740 79
1800 AMA 500L6A 481 992 96.5 96.7 0.88 0.87 203 5.4 53 17328 0.7 1.9 81.5 6040 79
2000 AMA 500L6A 482 993 96.6 96.8 0.87 0.84 230 5.9 74 19224 0.8 2.2 89.9 6380 79

750 r/min = 8 poles 6000 V 50 Hz


280 AMA 400L8A 114 740 94.1 94.3 0.83 0.79 35 5.0 14 3612 0.9 2.0 18.7 2860 77

2 315
355
AMA 400L8A
AMA 400L8A
115
116
740
741
94.1
94.5
94.5
94.7
0.84
0.83
0.81
0.79
38
44
4.7
5.1
14
17
4067
4577
0.8
0.9
1.9
2.1
20.1
21.5
2960
3050
77
77
400 AMA 400L8A 117 740 94.6 94.9 0.83 0.80 49 5.0 19 5159 0.9 2.0 22.9 3140 77
450 AMA 400L8A 118 740 94.7 95.0 0.83 0.80 55 4.9 21 5805 0.9 2.0 24.3 3240 77
500 AMA 400L8A 119 741 94.9 95.1 0.83 0.79 61 5.0 24 6448 0.9 2.0 25.7 3330 77
560 AMA 450L8A 120 743 95.3 95.4 0.81 0.77 69 5.2 30 7199 0.7 2.1 39.3 3880 77
630 AMA 450L8A 121 743 95.4 95.6 0.81 0.77 78 5.2 33 8098 0.7 2.1 41.9 4000 77
710 AMA 450L8A 122 742 95.6 95.9 0.85 0.82 84 5.1 29 9137 0.8 2.0 47.4 4240 77
800 AMA 450L8A 123 742 95.8 96.0 0.85 0.83 94 5.2 32 10294 0.8 2.0 52.6 4480 77
900 AMA 500L8A 124 742 95.8 96.1 0.86 0.84 105 4.9 32 11585 0.7 1.8 69.4 5130 77
1000 AMA 500L8A 125 742 95.9 96.3 0.87 0.85 116 4.9 33 12870 0.7 1.8 78.1 5430 77
1120 AMA 500L8A 126 743 96.1 96.4 0.87 0.85 129 5.2 39 14395 0.7 1.9 87.3 5700 77
1250 AMA 500L8A 127 743 96.2 96.4 0.86 0.83 146 5.2 48 16063 0.7 2.0 94.9 5990 77
1400 AMA 500L8A 483 743 96.3 96.5 0.86 0.84 162 5.3 51 17995 0.7 2.0 103.8 6290 77

Data presented in rating lists are typical values.


Guaranteed values on request. All engineered motors
are optimized for the specified application. Accurate
motor data will be given on request at quotation phase.
Legally binding performance and specification data is
given to the end user once each order is confirmed.

80 ABB/ BU Machines / HV Induction motors IEC catalogue / Engineered motors EN 05-2006


HV Modular motors 6000 V - 50 Hz
Technical data for totally enclosed squirrel
cage three phase motors
IP 55 - IC 611 - Insulation class F, temperature rise class B
Efficiency Power factor Current Torque Sound
Full 3/4 Full 3/4 IN IS I0 TN TS Tmax Rotor Motor pressure
Output Motor Product Speed load load load load inertia weight level LP
kW type ID r/min 100% 75% 100% 75% A IN A Nm TN TN kgm2 kg dB(A)

600 r/min = 10 poles 6000 V 50 Hz


200 AMA 400L10A 128 592 92.9 93.0 0.74 0.67 28 4.3 15 3227 0.7 1.9 17.4 2780 76
224 AMA 400L10A 129 592 93.1 93.2 0.75 0.69 31 4.2 16 3616 0.7 1.9 18.8 2870 76
250 AMA 400L10A 130 592 93.4 93.5 0.75 0.70 34 4.2 17 4036 0.7 1.9 20.2 2970 76
280 AMA 400L10A 131 592 93.6 93.7 0.75 0.70 38 4.3 19 4518 0.7 1.9 21.6 3060 76
315 AMA 400L10A 132 593 93.8 93.8 0.74 0.67 44 4.6 23 5072 0.8 1.9 24.4 3240 76
355 AMA 400L10A 133 593 93.9 94.0 0.75 0.69 49 4.4 25 5719 0.8 1.9 25.8 3330 76
450 AMA 450L10A 135 592 94.5 94.8 0.82 0.78 56 4.6 23 7254 0.8 1.9 41.9 3970 76
500 AMA 450L10A 136 593 94.7 94.9 0.81 0.77 63 4.8 26 8056 0.8 2.0 44.5 4090 76
560 AMA 450L10A 137 593 94.9 95.1 0.82 0.78 70 4.8 28 9022 0.8 2.0 49.7 4330 76
400 AMA 450L10A 134 592 94.3 94.6 0.81 0.78 50 4.6 20 6449 0.8 1.9 39.2 3850 76
630 AMA 500L10A 138 595 95.4 95.5 0.81 0.77 78 5.3 34 10116 0.7 2.2 74.4 5230 76
710 AMA 500L10A 139 594 95.5 95.6 0.83 0.78 87 5.2 35 11406 0.7 2.1 78.8 5380 76
800 AMA 500L10A 140 594 95.7 95.9 0.83 0.79 97 5.1 38 12857 0.7 2.0 83.2 5570 76
900 AMA 500L10A 141 594 95.9 96.0 0.83 0.80 108 5.2 42 14458 0.8 2.1 96.4 6010 76
1000 AMA 500L10A 484 594 95.8 96.0 0.84 0.81 120 5.1 44 16068 0.7 2.0 105.1 6270 76

500 r/min = 12 poles 6000 V 50 Hz


140
160
AMA 400L12A 142
AMA 400L12A 143
493
493
91.7
91.8
91.4
91.7
0.71
0.72
0.64
0.66
21
23
4.1 12
3.9 13
2711
3101
0.8
0.8
1.9
1.8
18.8
20.2
2870
2960
76
76
2
180 AMA 400L12A 144 493 92.1 92.0 0.72 0.66 26 3.9 14 3489 0.8 1.8 21.6 3050 76
200 AMA 400L12A 145 493 92.3 92.1 0.72 0.65 29 4.0 16 3874 0.8 1.8 23.0 3150 76
224 AMA 400L12A 146 493 92.3 92.0 0.70 0.64 33 4.2 19 4336 0.9 1.9 24.4 3230 76
250 AMA 400L12A 147 493 92.5 92.3 0.71 0.65 36 4.0 20 4842 0.8 1.8 25.8 3320 76
315 AMA 450L12A 149 495 93.9 93.8 0.72 0.65 45 4.7 26 6083 0.9 2.2 42.0 3970 76
355 AMA 450L12A 150 495 94.1 93.9 0.72 0.64 51 4.7 29 6855 0.9 2.1 44.6 4090 76
400 AMA 450L12A 151 494 94.3 94.2 0.73 0.67 56 4.6 30 7726 0.8 2.1 49.8 4320 76
450 AMA 450L12A 152 494 94.0 94.1 0.75 0.69 62 4.4 32 8699 0.8 1.9 52.4 4410 76
280 AMA 450L12A 148 495 93.8 93.6 0.71 0.64 40 4.7 24 5406 0.9 2.2 39.3 3850 76
500 AMA 500L12A 153 495 94.9 94.9 0.75 0.69 68 4.5 35 9650 0.7 2.0 73.7 5250 76
560 AMA 500L12A 154 494 94.8 94.8 0.77 0.72 74 4.5 35 10816 0.7 1.9 78.3 5370 76
630 AMA 500L12A 155 495 95.0 95.0 0.77 0.72 83 4.5 40 12164 0.7 1.9 87.0 5670 76
710 AMA 500L12A 156 494 95.2 95.2 0.77 0.72 93 4.4 43 13715 0.7 1.9 91.3 5850 76
800 AMA 500L12A 579 495 95.3 95.3 0.77 0.72 105 4.6 50 15444 0.7 1.9 104.4 6290 76

Data presented in rating lists are typical values.


Guaranteed values on request. All engineered motors
are optimized for the specified application. Accurate
motor data will be given on request at quotation phase.
Legally binding performance and specification data is
given to the end user once each order is confirmed.

ABB/ BU Machines / HV Induction motors IEC catalogue / Engineered motors EN 05-2006 81


HV Modular motors 10000 V - 50 Hz
Technical data for totally enclosed squirrel
cage three phase motors
IP 55 - IC 611 - Insulation class F, temperature rise class B

Efficiency Power factor Current Torque Sound


Full 3/4 Full 3/4 IN IS I0 TN TS Tmax Rotor Motor pressure
Output Motor Product Speed load load load load inertia weight level LP
kW type ID r/min 100% 75% 100% 75% A IN A Nm TN TN kgm2 kg dB(A)

3000 r/min = 2 poles 10000 V 50 Hz


560 AMA 450L2A 197 2979 94.2 93.8 0.86 0.84 40 4.8 12 1795 0.4 2.1 8.7 3560 86
630 AMA 450L2A 198 2978 94.5 94.3 0.87 0.85 44 4.9 12 2020 0.4 2.1 9.4 3710 86
710 AMA 450L2A 199 2977 94.8 94.7 0.88 0.86 49 5.0 13 2277 0.5 2.2 10.1 3850 86
800 AMA 450L2A 200 2980 95.2 95.1 0.88 0.87 55 5.3 14 2564 0.5 2.2 11.0 4000 86
900 AMA 450L2A 201 2981 95.5 95.4 0.87 0.86 62 5.3 16 2883 0.5 2.2 11.7 4140 86
1000 AMA 500L2A 202 2985 95.4 95.1 0.87 0.85 69 5.3 20 3199 0.4 2.2 18.6 4810 87
1120 AMA 500L2A 203 2985 95.7 95.4 0.88 0.86 77 5.3 21 3583 0.4 2.2 20.0 5000 87
1250 AMA 500L2A 204 2985 95.9 95.7 0.88 0.87 85 5.3 22 3999 0.5 2.2 21.3 5190 87
1400 AMA 500L2A 205 2986 96.1 96.0 0.88 0.87 95 5.3 24 4477 0.5 2.2 22.6 5370 87
1600 AMA 500L2A 497 2985 96.3 96.2 0.88 0.86 109 5.3 28 5118 0.5 2.1 23.9 5560 87

1500 r/min = 4 poles 10000 V 50 Hz


630 AMA 450L4A 206 1490 94.3 94.0 0.83 0.79 46 5.5 19 4038 0.6 2.2 24.1 3590 81
710 AMA 450L4A 207 1490 94.7 94.4 0.84 0.80 51 5.6 20 4550 0.6 2.2 25.8 3710 81
800 AMA 450L4A 208 1490 95.0 94.8 0.84 0.80 58 5.5 23 5126 0.6 2.1 27.4 3830 81
900 AMA 450L4A 209 1490 95.3 95.1 0.84 0.81 65 5.6 24 5767 0.6 2.1 29.2 3970 81
1000 AMA 500L4A 210 1491 94.5 94.4 0.86 0.83 71 5.3 24 6405 0.6 2.0 42.9 4760 82

2 1120
1250
AMA 500L4A
AMA 500L4A
211
212
1491
1491
94.8
95.3
94.7
95.2
0.87
0.88
0.85
0.86
78
86
5.2 23
5.4 25
7175
8007
0.6
0.7
2.0
2.0
45.8
48.4
4910
5080
82
82
1400 AMA 500L4A 213 1491 95.7 95.6 0.90 0.89 94 5.5 22 8965 0.6 2.0 54.9 5400 82
1600 AMA 500L4A 214 1491 95.9 95.9 0.90 0.89 107 5.6 26 10246 0.7 2.0 58.1 5570 82
1800 AMA 500L4A 498 1490 95.9 96.0 0.88 0.86 124 5.5 35 11536 0.6 2.1 57.0 5560 82
2000 AMA 500L4A 499 1491 96.1 96.1 0.85 0.82 141 5.7 47 12811 0.7 2.2 59.6 5720 82

Data presented in rating lists are typical values.


Guaranteed values on request. All engineered motors
are optimized for the specified application. Accurate
motor data will be given on request at quotation phase.
Legally binding performance and specification data is
given to the end user once each order is confirmed.

82 ABB/ BU Machines / HV Induction motors IEC catalogue / Engineered motors EN 05-2006


HV Modular motors 10000 V - 50 Hz
Technical data for totally enclosed squirrel
cage three phase motors
IP 55 - IC 611 - Insulation class F, temperature rise class B
Efficiency Power factor Current Torque Sound
Full 3/4 Full 3/4 IN IS I0 TN TS Tmax Rotor Motor pressure
Output Motor Product Speed load load load load inertia weight level LP
kW type ID r/min 100% 75% 100% 75% A IN A Nm TN TN kgm2 kg dB(A)

1000 r/min = 6 poles 10000 V 50 Hz


500 AMA 450L6A 216 992 94.9 94.8 0.84 0.80 36 5.6 14 4813 0.7 2.2 32.2 3730 79
560 AMA 450L6A 217 992 95.1 95.0 0.84 0.80 41 5.5 16 5391 0.7 2.2 34.3 3850 79
630 AMA 450L6A 218 992 95.3 95.2 0.83 0.79 46 5.6 19 6063 0.7 2.2 36.4 3970 79
710 AMA 450L6A 219 991 95.3 95.4 0.85 0.82 51 5.6 18 6840 0.7 2.1 36.7 3970 79
800 AMA 450L6A 220 992 95.5 95.5 0.83 0.79 58 5.6 23 7703 0.7 2.1 38.7 4090 79
900 AMA 500L6A 221 994 95.6 95.7 0.87 0.84 63 5.4 21 8649 0.6 2.1 63.0 5210 79
1000 AMA 500L6A 222 994 95.8 95.8 0.86 0.84 70 5.4 23 9609 0.6 2.1 66.4 5350 79
1120 AMA 500L6A 223 994 95.9 96.0 0.85 0.82 79 5.4 28 10760 0.6 2.1 69.7 5500 79
1250 AMA 500L6A 500 994 96.1 96.1 0.85 0.82 88 5.4 31 12009 0.6 2.1 73.3 5660 79
1400 AMA 500L6A 501 993 96.0 96.3 0.89 0.88 94 5.3 24 13469 0.7 2.0 81.7 5960 79

750 r/min = 8 poles 10000 V 50 Hz


630 AMA 500L8A 224 745 95.4 95.4 0.83 0.78 46 5.6 19 8076 0.7 2.2 65.5 4910 77
710 AMA 500L8A 225 746 95.6 95.6 0.82 0.77 52 5.5 22 9094 0.6 2.2 77.9 5330 77
800 AMA 500L8A 226 745 95.8 95.8 0.82 0.78 59 5.4 25 10248 0.6 2.2 82.2 5480 77
900 AMA 500L8A 227 745 95.9 95.9 0.82 0.77 66 5.5 28 11529 0.7 2.2 86.5 5620 77
1000 AMA 500L8A 502 745 96.0 96.0 0.82 0.78 73 5.4 30 12811 0.6 2.1 95.1 5920 77
1120 AMA 500L8A

600 r/min = 10 poles


503 745 96.0 96.1 0.84 0.81

10000 V 50 Hz
80 5.5 29 14359 0.7 2.0 95.8 5920 77
2
450 AMA 500L10A 228 595 94.4 94.4 0.81 0.75 34 5.6 16 7223 0.8 2.4 69.3 5000 76
500 AMA 500L10A 229 595 94.6 94.6 0.82 0.77 37 5.8 17 8028 0.9 2.4 73.8 5150 76
560 AMA 500L10A 230 595 94.8 94.8 0.82 0.76 42 5.7 19 8983 0.8 2.4 78.9 5300 76
630 AMA 500L10A 231 595 95.0 95.0 0.82 0.77 47 5.7 21 10108 0.8 2.3 83.3 5450 76
710 AMA 500L10A 504 595 95.1 95.1 0.81 0.76 53 5.7 24 11391 0.8 2.3 87.6 5600 76

500 r/min = 12 poles 10000 V 50 Hz


315 AMA 500L12A 232 495 93.4 93.5 0.77 0.71 25 4.7 13 6082 0.7 2.1 65.1 4870 76
355 AMA 500L12A 233 495 93.7 93.7 0.77 0.71 28 4.8 14 6852 0.7 2.2 69.4 5010 76
400 AMA 500L12A 234 495 93.9 93.8 0.76 0.69 33 4.9 17 7716 0.7 2.3 73.8 5160 76
450 AMA 500L12A 235 495 94.0 93.9 0.76 0.69 37 5.1 20 8678 0.8 2.3 82.5 5430 76
500 AMA 500L12A 236 495 94.1 94.1 0.76 0.69 40 5.0 21 9644 0.8 2.3 86.8 5580 76
560 AMA 500L12A 507 495 94.3 94.2 0.76 0.69 45 5.0 24 10802 0.8 2.3 91.1 5720 76

Data presented in rating lists are typical values.


Guaranteed values on request. All engineered motors
are optimized for the specified application. Accurate
motor data will be given on request at quotation phase.
Legally binding performance and specification data is
given to the end user once each order is confirmed.

ABB/ BU Machines / HV Induction motors IEC catalogue / Engineered motors EN 05-2006 83


HV Modular motors 3000 V - 50 Hz
Technical data for open weather protected
three phase motors
IP 24W - IC 01 - Insulation class F, temperature rise class B

Efficiency Power factor Current Torque Sound


Full 3/4 Full 3/4 IN IS I0 TN TS Tmax Rotor Motor pressure
Output Motor Product Speed load load load load inertia weight level LP
kW type ID r/min 100% 75% 100% 75% A IN A Nm TN TN kgm2 kg dB(A)

3000 r/min = 2 poles 3000 V 50 Hz


710 AMA 400L2W 1001 2973 95.9 96.1 0.86 0.84 166 4.8 45 2280 0.5 2.1 6.0 2880 82
800 AMA 400L2W 1002 2974 96.1 96.3 0.87 0.86 184 4.9 45 2569 0.5 2.1 6.5 2980 82
900 AMA 400L2W 1003 2974 96.2 96.4 0.88 0.87 204 4.9 47 2890 0.5 2.1 7.0 3070 82
1000 AMA 400L2W 1004 2977 96.4 96.6 0.88 0.87 226 5.1 53 3208 0.5 2.1 7.3 3190 82
1120 AMA 400L2W 1005 2976 96.5 96.7 0.88 0.87 253 5.3 60 3594 0.6 2.2 7.9 3310 82
1250 AMA 450L2W 1006 2977 96.6 96.7 0.88 0.86 284 4.8 69 4010 0.5 2.0 12.0 4080 83
1400 AMA 450L2W 1007 2978 96.7 96.9 0.86 0.85 324 4.8 84 4489 0.5 2.0 12.7 4220 83
1600 AMA 450L2W 1008 2979 96.9 97.1 0.87 0.85 367 5.0 92 5129 0.5 2.1 14.2 4520 83
1800 AMA 500L2W 1009 2986 97.0 97.0 0.85 0.82 421 5.3 140 5756 0.4 2.2 19.6 5110 84
2000 AMA 500L2W 1010 2984 97.0 97.1 0.88 0.87 448 5.1 112 6401 0.4 2.1 21.0 5300 84
2240 AMA 500L2W 1011 2987 97.3 97.2 0.84 0.81 527 5.7 183 7162 0.5 2.4 22.3 5500 84
2500 AMA 500L2W 1168 2984 97.3 97.4 0.89 0.88 554 5.2 126 8000 0.5 2.1 25.0 5880 84

1500 r/min = 4 poles 3000 V 50 Hz


710 AMA 400L4W 1012 1488 95.8 95.9 0.80 0.75 178 5.3 79 4556 0.7 2.3 13.8 2850 79
800 AMA 400L4W 1013 1488 96.0 96.1 0.81 0.77 197 5.3 82 5134 0.7 2.2 14.8 2960 79
900 AMA 400L4W 1014 1488 96.2 96.3 0.81 0.77 221 5.4 91 5776 0.7 2.3 15.8 3070 79

2 1000
1120
AMA 400L4W
AMA 400L4W
1015
1016
1487
1487
96.2
96.3
96.4
96.5
0.85
0.84
0.83
0.81
235
265
5.0 78
5.3 94
6423
7192
0.6
0.7
2.0
2.1
16.8
17.7
3160
3260
79
79
1250 AMA 400L4W 1017 1487 96.4 96.6 0.83 0.80 299 5.3 108 8025 0.7 2.2 18.7 3370 79
1400 AMA 450L4W 1018 1486 96.2 96.5 0.87 0.86 321 4.9 85 8996 0.6 1.9 29.1 4000 80
1600 AMA 450L4W 1019 1486 96.4 96.7 0.88 0.88 361 5.0 86 10281 0.7 1.9 32.5 4260 80
1800 AMA 450L4W 1020 1487 96.6 96.9 0.89 0.88 404 5.3 99 11559 0.7 2.0 35.9 4520 80
2000 AMA 500L4W 1021 1490 96.6 96.8 0.89 0.88 450 4.9 106 12822 0.6 1.8 52.7 5330 81
2240 AMA 500L4W 1022 1490 96.7 96.9 0.88 0.88 505 4.9 121 14360 0.6 1.8 55.6 5490 81
2500 AMA 500L4W 1023 1490 96.8 97.0 0.89 0.88 559 5.3 133 16020 0.7 1.9 61.6 5790 81
2800 AMA 500L4W 1157 1490 97.0 97.2 0.89 0.89 621 5.5 142 17940 0.7 2.0 67.5 6140 81

Data presented in rating lists are typical values.


Guaranteed values on request. All engineered motors
are optimized for the specified application. Accurate
motor data will be given on request at quotation phase.
Legally binding performance and specification data is
given to the end user once each order is confirmed.

84 ABB/ BU Machines / HV Induction motors IEC catalogue / Engineered motors EN 05-2006


HV Modular motors 3000 V - 50 Hz
Technical data for open weather protected
three phase motors
IP 24W - IC 01 - Insulation class F, temperature rise class B
Efficiency Power factor Current Torque Sound
Full 3/4 Full 3/4 IN IS I0 TN TS Tmax Rotor Motor pressure
Output Motor Product Speed load load load load inertia weight level LP
kW type ID r/min 100% 75% 100% 75% A IN A Nm TN TN kgm2 kg dB(A)

1000 r/min = 6 poles 3000 V 50 Hz


500 AMA 400L6W 1024 986 95.1 95.5 0.84 0.82 120 4.4 40 4842 0.7 1.7 15.3 2780 77
560 AMA 400L6W 1025 987 95.4 95.6 0.83 0.80 135 4.8 49 5416 0.7 1.9 16.5 2880 77
630 AMA 400L6W 1026 987 95.3 95.7 0.84 0.82 151 4.6 50 6096 0.7 1.8 17.7 2960 77
710 AMA 400L6W 1027 988 95.6 95.9 0.84 0.81 169 5.0 59 6861 0.8 1.9 20.1 3150 77
800 AMA 400L6W 1028 988 95.7 96.0 0.84 0.81 192 5.1 69 7730 0.8 2.0 21.2 3250 77
900 AMA 400L6W 1029 988 95.8 96.1 0.85 0.82 213 5.1 71 8697 0.8 1.9 23.6 3440 77
1000 AMA 450L6W 1030 992 96.3 96.4 0.81 0.77 245 5.3 101 9626 0.7 2.1 36.8 4020 78
1120 AMA 450L6W 1031 991 96.3 96.6 0.86 0.84 260 5.1 81 10796 0.7 2.0 39.4 4140 78
1250 AMA 450L6W 1032 990 96.2 96.6 0.87 0.85 289 4.8 80 12059 0.6 1.8 41.6 4250 78
1400 AMA 450L6W 1033 990 96.3 96.7 0.87 0.86 322 5.0 89 13502 0.7 1.9 46.0 4490 78
1600 AMA 500L6W 1034 991 96.5 96.8 0.88 0.87 362 5.1 94 15419 0.7 1.9 64.4 5300 79
1800 AMA 500L6W 1035 992 96.6 96.9 0.88 0.86 408 5.5 112 17334 0.8 2.0 71.5 5570 79
2000 AMA 500L6W 1158 991 96.7 97.0 0.89 0.88 447 5.3 105 19272 0.8 1.9 78.8 5890 79
2250 AMA 500L6W 1159 991 96.8 97.1 0.89 0.88 503 5.4 121 21674 0.8 2.0 86.0 6190 79

750 r/min = 8 poles 3000 V 50 Hz


315 AMA 400L8W 1036 738 94.5 94.9 0.83 0.80 77 4.4 27 4076 0.8 1.8 17.1 2730 75
355
400
AMA 400L8W
AMA 400L8W
1037
1038
739
739
94.6
94.9
95.0
95.3
0.83
0.83
0.80
0.80
87
97
4.6 32
4.6 35
4585
5166
0.8
0.8
1.8
1.9
18.6
20.0
2830
2930
75
75
2
450 AMA 400L8W 1039 739 95.1 95.4 0.84 0.81 109 4.5 37 5814 0.8 1.8 21.4 3040 75
500 AMA 400L8W 1040 739 95.1 95.4 0.84 0.81 121 4.5 41 6460 0.8 1.8 22.8 3120 75
560 AMA 400L8W 1041 739 95.2 95.5 0.84 0.81 135 4.6 47 7233 0.8 1.8 24.2 3220 75
630 AMA 400L8W 1042 739 95.2 95.6 0.84 0.82 151 4.5 50 8140 0.8 1.8 26.9 3400 75
710 AMA 450L8W 1043 742 95.8 96.0 0.83 0.79 172 5.1 66 9138 0.8 2.0 39.9 3850 76
800 AMA 450L8W 1044 741 95.8 96.2 0.85 0.84 188 4.6 58 10311 0.7 1.8 45.2 4090 76
900 AMA 450L8W 1045 741 95.8 96.3 0.86 0.84 211 4.6 63 11598 0.7 1.8 50.4 4310 76
1000 AMA 450L8W 1046 743 96.2 96.4 0.83 0.79 240 5.5 93 12854 0.8 2.1 55.5 4550 76
1120 AMA 500L8W 1047 739 95.8 96.4 0.87 0.86 258 4.3 66 14464 0.6 1.7 74.1 5240 77
1250 AMA 500L8W 1048 741 96.2 96.6 0.87 0.86 288 4.6 76 16105 0.7 1.7 83.3 5550 77
1400 AMA 500L8W 1049 742 96.4 96.7 0.86 0.85 323 5.1 96 18016 0.7 1.9 91.9 5830 77
1600 AMA 500L8W 1160 742 96.3 96.7 0.87 0.86 368 4.8 101 20602 0.7 1.8 100.6 6140 77

Data presented in rating lists are typical values.


Guaranteed values on request. All engineered motors
are optimized for the specified application. Accurate
motor data will be given on request at quotation phase.
Legally binding performance and specification data is
given to the end user once each order is confirmed.

ABB/ BU Machines / HV Induction motors IEC catalogue / Engineered motors EN 05-2006 85


HV Modular motors 3000 V - 50 Hz
Technical data for open weather protected
three phase motors
IP 24W - IC 01 - Insulation class F, temperature rise class B

Efficiency Power factor Current Torque Sound


Full 3/4 Full 3/4 IN IS I0 TN TS Tmax Rotor Motor pressure
Output Motor Product Speed load load load load inertia weight level LP
kW type ID r/min 100% 75% 100% 75% A IN A Nm TN TN kgm2 kg dB(A)

600 r/min = 10 poles 3000 V 50 Hz


224 AMA 400L10W 1050 591 93.6 93.8 0.75 0.70 61 4.0 30 3621 0.7 1.8 15.9 2660 75
250 AMA 400L10W 1051 590 93.8 94.0 0.76 0.71 67 4.0 31 4043 0.7 1.7 17.3 2750 75
280 AMA 400L10W 1052 590 93.9 94.2 0.77 0.72 75 3.9 34 4528 0.7 1.7 18.7 2850 75
315 AMA 400L10W 1053 591 94.0 94.3 0.77 0.72 84 4.0 38 5093 0.7 1.7 20.1 2940 75
355 AMA 400L10W 1054 592 94.3 94.4 0.75 0.70 96 4.3 46 5725 0.8 1.8 22.9 3120 75
400 AMA 400L10W 1055 592 94.5 94.7 0.76 0.71 107 4.1 49 6455 0.7 1.7 24.3 3240 75
450 AMA 400L10W 1056 592 94.7 94.7 0.75 0.70 122 4.4 60 7253 0.8 1.9 27.1 3430 75
500 AMA 450L10W 1057 591 94.8 95.3 0.82 0.79 124 4.2 45 8074 0.7 1.7 39.7 3840 76
560 AMA 450L10W 1058 592 95.0 95.4 0.82 0.79 139 4.3 53 9038 0.7 1.8 42.3 3960 76
630 AMA 450L10W 1059 592 95.1 95.5 0.82 0.79 155 4.3 57 10167 0.7 1.8 47.5 4200 76
710 AMA 450L10W 1060 592 95.2 95.6 0.83 0.80 173 4.2 60 11459 0.7 1.7 55.3 4560 76
800 AMA 500L10W 1061 594 95.8 96.0 0.82 0.78 197 4.9 79 12857 0.7 2.0 75.2 5200 77
900 AMA 500L10W 1062 593 95.9 96.2 0.84 0.81 216 4.6 75 14484 0.6 1.8 79.8 5390 77
1000 AMA 500L10W 1063 594 96.0 96.2 0.84 0.81 239 4.8 84 16083 0.7 1.9 93.0 5810 77
1120 AMA 500L10W 1161 594 96.1 96.3 0.83 0.79 271 5.0 104 17997 0.7 2.0 101.4 6110 77

500 r/min = 12 poles 3000 V 50 Hz

2 160
180
AMA 400L12W 1064
AMA 400L12W 1065
491
492
92.5
92.8
92.5
92.8
0.73
0.73
0.67
0.68
46
51
3.8 23
3.8 25
3110
3495
0.8
0.8
1.7
1.7
17.3
18.8
2740
2840
75
75
200 AMA 400L12W 1066 492 92.9 93.0 0.74 0.68 56 3.8 28 3883 0.8 1.7 20.2 2940 75
224 AMA 400L12W 1067 492 93.1 93.1 0.73 0.68 63 3.9 32 4347 0.8 1.7 21.6 3030 75
250 AMA 400L12W 1068 493 93.3 93.2 0.72 0.66 72 4.1 38 4846 0.9 1.8 23.0 3130 75
280 AMA 400L12W 1069 492 93.1 93.2 0.73 0.68 79 3.8 40 5433 0.8 1.7 24.4 3210 75
315 AMA 400L12W 1070 493 93.4 93.3 0.72 0.67 90 4.0 47 6106 0.8 1.8 27.2 3400 75
355 AMA 450L12W 1071 494 94.5 94.5 0.73 0.68 98 4.2 51 6866 0.7 1.9 39.8 3820 76
400 AMA 450L12W 1072 494 94.6 94.7 0.73 0.67 111 4.2 58 7736 0.7 1.9 42.4 3940 76
450 AMA 450L12W 1073 494 94.7 94.8 0.75 0.69 122 4.1 60 8707 0.7 1.8 47.6 4180 76
500 AMA 450L12W 1074 493 94.5 94.8 0.76 0.71 135 3.9 63 9681 0.7 1.7 50.2 4270 76
560 AMA 450L12W 1075 493 94.7 94.9 0.75 0.70 151 4.0 73 10837 0.7 1.8 55.5 4520 76
630 AMA 500L12W 1076 493 95.0 95.3 0.78 0.74 164 3.9 71 12198 0.6 1.7 74.7 5190 77
710 AMA 500L12W 1077 493 95.2 95.4 0.78 0.74 184 4.0 79 13743 0.6 1.7 83.4 5500 77
800 AMA 500L12W 1078 493 95.3 95.5 0.78 0.74 206 3.9 86 15494 0.6 1.7 87.7 5680 77
900 AMA 500L12W 1170 493 95.4 95.6 0.78 0.74 232 4.1 100 17416 0.6 1.8 100.8 6100 77

Data presented in rating lists are typical values.


Guaranteed values on request. All engineered motors
are optimized for the specified application. Accurate
motor data will be given on request at quotation phase.
Legally binding performance and specification data is
given to the end user once each order is confirmed.

86 ABB/ BU Machines / HV Induction motors IEC catalogue / Engineered motors EN 05-2006


HV Modular motors 6000 V - 50 Hz
Technical data for open weather protected
three phase motors
IP 24W - IC 01 - Insulation class F, temperature rise class B

Efficiency Power factor Current Torque Sound


Full 3/4 Full 3/4 IN IS I0 TN TS Tmax Rotor Motor pressure
Output Motor Product Speed load load load load inertia weight level LP
kW type ID r/min 100% 75% 100% 75% A IN A Nm TN TN kgm2 kg dB(A)

3000 r/min = 2 poles 6000 V 50 Hz


710 AMA 400L2W 1 2973 95.6 95.8 0.86 0.84 83 4.7 22 2281 0.5 2.0 6.0 2820 82
800 AMA 400L2W 2 2974 95.8 96.0 0.87 0.86 92 4.9 23 2569 0.5 2.1 6.5 2920 82
900 AMA 400L2W 3 2974 96.0 96.3 0.88 0.87 102 4.9 23 2890 0.5 2.1 7.0 3030 82
1000 AMA 400L2W 4 2977 96.2 96.5 0.88 0.87 113 5.1 26 3208 0.5 2.1 7.3 3140 82
1120 AMA 400L2W 5 2976 96.3 96.6 0.88 0.87 127 5.3 30 3594 0.6 2.2 7.9 3260 82
1250 AMA 450L2W 6 2977 96.5 96.6 0.88 0.86 142 4.8 34 4010 0.5 2.0 12.0 4020 83
1400 AMA 450L2W 7 2978 96.6 96.8 0.86 0.85 162 4.8 42 4489 0.5 2.1 12.7 4170 83
1600 AMA 450L2W 8 2979 96.8 97.0 0.87 0.86 184 5.0 46 5129 0.5 2.1 14.2 4460 83
1800 AMA 500L2W 9 2984 96.8 96.9 0.88 0.87 203 5.1 52 5761 0.4 2.1 19.7 5030 84
2000 AMA 500L2W 10 2984 97.0 97.1 0.89 0.87 224 5.2 56 6401 0.4 2.1 21.0 5230 84
2240 AMA 500L2W 11 2984 97.1 97.2 0.89 0.87 250 5.3 63 7168 0.5 2.2 22.3 5420 84
2500 AMA 500L2W 578 2984 97.2 97.3 0.89 0.88 277 5.3 63 8000 0.5 2.1 25.0 5790 84

1500 r/min = 4 poles 6000 V 50 Hz


710 AMA 400L4W 12 1486 95.5 95.8 0.86 0.83 83 5.0 28 4562 0.6 2.0 13.9 2810 79
800 AMA 400L4W 13 1486 95.7 96.0 0.87 0.85 93 5.0 28 5142 0.6 2.0 14.9 2910 79
900 AMA 400L4W 14 1486 95.8 96.2 0.87 0.85 103 5.0 30 5785 0.6 2.0 15.9 3010 79
1000
1120
AMA 400L4W
AMA 400L4W
15
16
1484
1484
95.7
95.8
96.2
96.3
0.89
0.89
0.89
0.88
113 4.7 26
126 4.8 30
6435
7206
0.6
0.6
1.9
1.9
16.9
17.9
3100
3200
79
79
2
1250 AMA 450L4W 17 1487 95.9 96.2 0.86 0.84 145 5.0 43 8029 0.6 1.9 27.3 3810 80
1400 AMA 450L4W 18 1486 96.1 96.4 0.87 0.86 160 5.0 42 8996 0.7 1.9 29.1 3940 80
1600 AMA 450L4W 19 1486 96.3 96.6 0.89 0.88 180 5.1 43 10281 0.7 1.9 32.5 4210 80
1800 AMA 500L4W 20 1489 96.3 96.5 0.89 0.88 203 5.0 49 11540 0.6 1.8 49.8 5070 81
2000 AMA 500L4W 21 1490 96.4 96.6 0.89 0.88 225 5.0 53 12822 0.6 1.8 52.7 5230 81
2240 AMA 500L4W 22 1490 96.5 96.8 0.89 0.88 252 5.1 60 14359 0.6 1.8 55.6 5390 81
2500 AMA 500L4W 23 1490 96.7 97.0 0.89 0.88 281 5.3 68 16021 0.7 1.9 61.2 5710 81
2800 AMA 500L4W 472 1490 96.9 97.1 0.89 0.88 312 5.5 73 17941 0.7 2.0 67.2 6020 81

Data presented in rating lists are typical values.


Guaranteed values on request. All engineered motors
are optimized for the specified application. Accurate
motor data will be given on request at quotation phase.
Legally binding performance and specification data is
given to the end user once each order is confirmed.

ABB/ BU Machines / HV Induction motors IEC catalogue / Engineered motors EN 05-2006 87


HV Modular motors 6000 V - 50 Hz
Technical data for open weather protected
three phase motors
IP 24W - IC 01 - Insulation class F, temperature rise class B

Efficiency Power factor Current Torque Sound


Full 3/4 Full 3/4 IN IS I0 TN TS Tmax Rotor Motor pressure
Output Motor Product Speed load load load load inertia weight level LP
kW type ID r/min 100% 75% 100% 75% A IN A Nm TN TN kgm2 kg dB(A)

1000 r/min = 6 poles 6000 V 50 Hz


500 AMA 400L6W 24 986 94.8 95.2 0.85 0.82 60 4.5 20 4842 0.7 1.7 15.3 2730 77
560 AMA 400L6W 25 987 95.0 95.3 0.84 0.81 68 4.9 25 5416 0.8 1.9 16.5 2810 77
630 AMA 400L6W 26 987 95.1 95.5 0.85 0.82 75 4.7 25 6096 0.7 1.8 17.7 2910 77
710 AMA 400L6W 27 988 95.4 95.7 0.85 0.82 85 5.1 30 6861 0.8 1.9 20.1 3100 77
800 AMA 400L6W 28 988 95.5 95.8 0.84 0.81 96 5.2 35 7730 0.9 2.0 21.2 3190 77
900 AMA 450L6W 29 991 95.8 96.1 0.86 0.83 106 5.2 35 8674 0.7 2.0 35.0 3830 78
1000 AMA 450L6W 30 990 96.0 96.4 0.87 0.85 115 5.0 34 9643 0.7 1.9 37.2 3950 78
1120 AMA 450L6W 31 991 96.2 96.5 0.86 0.84 130 5.2 40 10796 0.7 2.0 39.4 4080 78
1250 AMA 450L6W 32 990 96.1 96.5 0.87 0.85 144 4.9 40 12059 0.7 1.9 41.6 4190 78
1400 AMA 450L6W 33 990 96.2 96.6 0.87 0.86 161 5.0 45 13502 0.7 1.9 46.0 4430 78
1600 AMA 500L6W 34 991 96.3 96.7 0.88 0.87 181 5.2 47 15419 0.7 1.9 64.4 5210 79
1800 AMA 500L6W 35 991 96.4 96.8 0.89 0.88 203 5.2 50 17344 0.7 1.9 71.5 5500 79
2000 AMA 500L6W 473 991 96.5 96.9 0.89 0.88 224 5.2 53 19272 0.7 1.9 78.6 5800 79
2250 AMA 500L6W 474 991 96.6 97.0 0.89 0.89 252 5.3 59 21679 0.8 1.9 85.8 6100 79

750 r/min = 8 poles 6000 V 50 Hz


315 AMA 400L8W 36 739 94.0 94.5 0.83 0.80 39 4.5 14 4071 0.8 1.8 17.2 2700 75

2 355
400
AMA 400L8W
AMA 400L8W
37
38
739
739
94.0
94.4
94.5
94.9
0.83
0.84
0.80
0.81
44
49
4.5
4.6
16
17
4586
5167
0.8
0.8
1.8
1.8
18.6
20.0
2790
2880
75
75
450 AMA 400L8W 39 739 94.5 95.0 0.84 0.81 55 4.4 19 5815 0.8 1.8 21.4 2980 75
500 AMA 400L8W 40 739 94.6 95.1 0.84 0.81 61 4.5 21 6461 0.8 1.8 22.8 3070 75
560 AMA 400L8W 41 739 94.7 95.2 0.84 0.81 68 4.5 24 7234 0.8 1.8 24.2 3170 75
630 AMA 450L8W 42 742 95.3 95.7 0.83 0.80 76 5.1 29 8109 0.8 2.0 37.3 3670 76
710 AMA 450L8W 43 742 95.4 95.8 0.83 0.80 86 5.1 33 9138 0.8 2.0 39.9 3800 76
800 AMA 450L8W 44 741 95.5 96.0 0.85 0.84 94 4.6 29 10311 0.7 1.7 45.2 4030 76
900 AMA 450L8W 45 741 95.7 96.1 0.86 0.84 106 4.6 32 11598 0.7 1.8 50.4 4280 76
1000 AMA 500L8W 46 739 95.5 96.1 0.87 0.85 116 4.4 32 12915 0.6 1.7 65.5 4870 77
1120 AMA 500L8W 47 739 95.6 96.2 0.87 0.86 129 4.3 33 14465 0.6 1.7 74.1 5170 77
1250 AMA 500L8W 48 741 95.9 96.4 0.87 0.86 144 4.6 38 16102 0.6 1.7 83.4 5440 77
1400 AMA 500L8W 49 742 96.2 96.5 0.87 0.85 162 5.1 48 18012 0.7 1.9 92.1 5750 77
1600 AMA 500L8W 475 742 96.2 96.6 0.87 0.86 184 4.9 51 20597 0.7 1.8 100.7 6040 77

Data presented in rating lists are typical values.


Guaranteed values on request. All engineered motors
are optimized for the specified application. Accurate
motor data will be given on request at quotation phase.
Legally binding performance and specification data is
given to the end user once each order is confirmed.

88 ABB/ BU Machines / HV Induction motors IEC catalogue / Engineered motors EN 05-2006


HV Modular motors 6000 V - 50 Hz
Technical data for open weather protected
three phase motors
IP 24W - IC 01 - Insulation class F, temperature rise class B
Efficiency Power factor Current Torque Sound
Full 3/4 Full 3/4 IN IS I0 TN TS Tmax Rotor Motor pressure
Output Motor Product Speed load load load load inertia weight level LP
kW type ID r/min 100% 75% 100% 75% A IN A Nm TN TN kgm2 kg dB(A)

600 r/min = 10 poles 6000 V 50 Hz


224 AMA 400L10W 50 591 92.9 93.2 0.75 0.70 31 4.0 15 3622 0.7 1.8 15.9 2620 75
250 AMA 400L10W 51 590 93.0 93.4 0.77 0.72 34 3.9 16 4044 0.6 1.7 17.3 2710 75
280 AMA 400L10W 52 590 93.2 93.7 0.77 0.73 37 3.9 17 4529 0.6 1.7 18.7 2800 75
315 AMA 400L10W 53 591 93.5 93.9 0.77 0.72 42 3.9 19 5094 0.7 1.7 20.1 2900 75
355 AMA 400L10W 54 592 93.8 94.0 0.76 0.70 48 4.3 23 5726 0.8 1.8 22.9 3070 75
400 AMA 400L10W 55 592 93.9 94.1 0.76 0.72 54 4.1 25 6456 0.7 1.7 24.3 3170 75
450 AMA 450L10W 56 591 94.2 94.8 0.82 0.79 56 4.1 20 7269 0.7 1.7 37.0 3650 76
500 AMA 450L10W 57 591 94.4 94.9 0.82 0.79 62 4.2 23 8074 0.7 1.7 39.7 3770 76
560 AMA 450L10W 58 592 94.5 95.0 0.82 0.79 69 4.3 26 9039 0.7 1.7 42.3 3890 76
630 AMA 450L10W 59 592 94.7 95.2 0.82 0.79 78 4.3 28 10168 0.7 1.7 47.5 4130 76
710 AMA 500L10W 60 594 95.4 95.7 0.83 0.79 87 4.8 34 11415 0.7 1.9 71.0 4980 77
800 AMA 500L10W 61 594 95.4 95.8 0.83 0.80 97 4.7 35 12869 0.7 1.9 75.4 5130 77
900 AMA 500L10W 62 593 95.6 96.0 0.84 0.81 108 4.5 38 14484 0.6 1.8 79.8 5320 77
1000 AMA 500L10W 63 594 95.8 96.1 0.84 0.81 119 4.7 42 16083 0.7 1.9 93.0 5760 77
1120 AMA 500L10W 476 594 95.7 96.1 0.85 0.82 133 4.6 44 18020 0.7 1.8 101.7 6030 77

500 r/min = 12 poles 6000 V 50 Hz


160
180
AMA 400L12W 64
AMA 400L12W 65
492
492
91.6
91.8
91.8
92.0
0.73
0.74
0.68
0.69
23
25
3.8 12
3.7 13
3106
3496
0.8
0.7
1.7
1.7
17.4
18.8
2700
2790
75
75
2
200 AMA 400L12W 66 492 92.0 92.2 0.74 0.69 28 3.7 14 3884 0.7 1.7 20.2 2890 75
224 AMA 400L12W 67 492 92.3 92.4 0.74 0.68 32 3.8 16 4348 0.8 1.7 21.6 2980 75
250 AMA 400L12W 68 492 92.3 92.3 0.73 0.67 36 4.0 19 4848 0.8 1.8 23.0 3060 75
280 AMA 400L12W 69 492 92.4 92.5 0.73 0.68 40 3.8 20 5434 0.8 1.7 24.4 3160 75
315 AMA 450L12W 70 494 93.8 93.9 0.73 0.67 44 4.3 24 6091 0.8 2.0 37.1 3640 76
355 AMA 450L12W 71 494 93.9 94.0 0.74 0.68 49 4.3 26 6866 0.8 1.9 39.8 3760 76
400 AMA 450L12W 72 494 94.1 94.2 0.74 0.68 55 4.3 29 7736 0.8 1.9 42.4 3880 76
450 AMA 450L12W 73 494 94.2 94.4 0.75 0.70 61 4.2 30 8706 0.7 1.8 47.6 4120 76
500 AMA 450L12W 74 493 93.9 94.2 0.76 0.71 67 4.0 32 9681 0.7 1.7 50.2 4200 76
560 AMA 500L12W 75 494 94.6 94.8 0.77 0.72 74 4.2 35 10831 0.6 1.9 70.3 4960 77
630 AMA 500L12W 76 493 94.6 94.9 0.78 0.74 82 4.1 36 12197 0.6 1.8 74.7 5110 77
710 AMA 500L12W 77 493 94.8 95.1 0.79 0.74 92 4.1 40 13741 0.6 1.8 83.4 5410 77
800 AMA 500L12W 78 493 95.0 95.3 0.79 0.75 103 4.0 43 15491 0.6 1.7 87.7 5600 77
900 AMA 500L12W 580 494 95.2 95.4 0.79 0.74 116 4.2 50 17414 0.6 1.8 100.8 6040 77

Data presented in rating lists are typical values.


Guaranteed values on request. All engineered motors
are optimized for the specified application. Accurate
motor data will be given on request at quotation phase.
Legally binding performance and specification data is
given to the end user once each order is confirmed.

ABB/ BU Machines / HV Induction motors IEC catalogue / Engineered motors EN 05-2006 89


HV Modular motors 10000 V - 50 Hz
Technical data for open weather protected
three phase motors
IP 24W - IC 01 - Insulation class F, temperature rise class B

Efficiency Power factor Current Torque Sound


Full 3/4 Full 3/4 IN IS I0 TN TS Tmax Rotor Motor pressure
Output Motor Product Speed load load load load inertia weight level LP
kW type ID r/min 100% 75% 100% 75% A IN A Nm TN TN kgm2 kg dB(A)

3000 r/min = 2 poles 10000 V 50 Hz


630 AMA 450L2W 157 2980 95.2 95.1 0.84 0.81 45 5.1 15 2019 0.4 2.3 9.1 3370 83
710 AMA 450L2W 158 2980 95.5 95.5 0.86 0.83 50 5.3 16 2275 0.5 2.3 9.8 3520 83
800 AMA 450L2W 159 2981 95.8 95.8 0.86 0.83 56 5.3 17 2563 0.5 2.3 10.6 3660 83
900 AMA 450L2W 160 2980 95.8 96.0 0.88 0.86 62 5.2 16 2884 0.5 2.2 11.4 3790 83
1000 AMA 450L2W 161 2979 96.1 96.2 0.88 0.87 68 5.1 16 3206 0.5 2.2 12.1 3950 83
1120 AMA 500L2W 162 2985 96.0 95.9 0.87 0.84 78 5.3 23 3583 0.4 2.2 17.3 4580 84
1250 AMA 500L2W 163 2985 96.2 96.2 0.87 0.86 86 5.3 24 3999 0.4 2.2 18.7 4770 84
1400 AMA 500L2W 164 2985 96.4 96.4 0.88 0.86 96 5.4 26 4479 0.5 2.2 20.0 4960 84
1600 AMA 500L2W 165 2984 96.5 96.6 0.89 0.89 107 5.2 24 5120 0.5 2.1 21.4 5160 84
1800 AMA 500L2W 485 2985 96.7 96.8 0.89 0.88 120 5.4 28 5759 0.5 2.2 22.4 5340 84

1500 r/min = 4 poles 10000 V 50 Hz


710 AMA 450L4W 166 1489 95.0 95.0 0.85 0.82 51 5.4 18 4554 0.6 2.1 22.2 3380 80
800 AMA 450L4W 167 1489 95.3 95.4 0.86 0.83 56 5.5 19 5131 0.7 2.1 23.9 3510 80
900 AMA 450L4W 168 1489 95.5 95.6 0.86 0.83 63 5.5 21 5771 0.7 2.1 25.5 3630 80
1000 AMA 450L4W 169 1489 95.7 95.8 0.86 0.84 70 5.6 23 6412 0.7 2.1 27.3 3770 80
1120 AMA 500L4W 170 1491 95.4 95.4 0.88 0.86 77 5.5 22 7172 0.5 2.2 43.6 4670 81

2 1250
1400
AMA 500L4W
AMA 500L4W
171
172
1491
1491
95.8
96.0
95.9
96.1
0.89
0.89
0.87
0.87
85
95
5.6 24
5.6 26
8004
8964
0.5
0.6
2.1
2.1
46.2
49.0
4840
4990
81
81
1600 AMA 500L4W 173 1491 96.2 96.3 0.88 0.86 109 5.4 31 10245 0.5 2.0 51.7 5150 81
1800 AMA 500L4W 174 1489 96.2 96.3 0.88 0.87 123 5.5 33 11544 0.7 2.1 54.1 5310 81
2000 AMA 500L4W 486 1491 96.4 96.5 0.87 0.85 138 6.0 43 12810 0.7 2.3 57.2 5460 81
2240 AMA 500L4W 487 1490 96.3 96.5 0.88 0.86 152 5.6 42 14359 0.7 2.2 57.6 5460 81

Data presented in rating lists are typical values.


Guaranteed values on request. All engineered motors
are optimized for the specified application. Accurate
motor data will be given on request at quotation phase.
Legally binding performance and specification data is
given to the end user once each order is confirmed.

90 ABB/ BU Machines / HV Induction motors IEC catalogue / Engineered motors EN 05-2006


HV Modular motors 10000 V - 50 Hz
Technical data for open weather protected
three phase motors
IP 24W - IC 01 - Insulation class F, temperature rise class B

Efficiency Power factor Current Torque Sound


Full 3/4 Full 3/4 IN IS I0 TN TS Tmax Rotor Motor pressure
Output Motor Product Speed load load load load inertia weight level LP
kW type ID r/min 100% 75% 100% 75% A IN A Nm TN TN kgm2 kg dB(A)

1000 r/min = 6 poles 10000 V 50 Hz


560 AMA 450L6W 176 991 95.2 95.4 0.85 0.82 40 5.6 14 5396 0.7 2.2 30.3 3530 78
630 AMA 450L6W 177 991 95.4 95.6 0.86 0.82 45 5.6 16 6071 0.7 2.1 32.4 3650 78
710 AMA 450L6W 178 991 95.6 95.8 0.85 0.82 50 5.7 18 6840 0.7 2.1 34.5 3770 78
800 AMA 450L6W 179 990 95.5 95.8 0.86 0.84 56 5.4 18 7716 0.7 2.0 34.7 3770 78
900 AMA 450L6W 180 991 95.7 95.9 0.85 0.82 64 5.6 23 8676 0.8 2.1 36.8 3880 78
1000 AMA 500L6W 181 994 95.9 96.1 0.87 0.85 69 5.4 21 9611 0.6 2.1 60.7 4970 79
1120 AMA 500L6W 182 994 96.0 96.3 0.87 0.85 77 5.4 24 10763 0.6 2.0 64.1 5120 79
1250 AMA 500L6W 183 993 96.1 96.3 0.87 0.85 86 5.4 27 12018 0.6 2.0 66.9 5260 79
1400 AMA 500L6W 488 993 96.2 96.5 0.87 0.85 97 5.4 30 13460 0.6 2.0 70.5 5420 79
1600 AMA 500L6W 489 993 96.4 96.6 0.87 0.85 110 5.4 34 15382 0.7 2.0 77.5 5710 79

750 r/min = 8 poles 10000 V 50 Hz


710 AMA 500L8W 184 744 95.5 95.7 0.84 0.81 51 5.4 19 9110 0.7 2.0 62.5 4670 77
800 AMA 500L8W 185 745 95.7 95.9 0.84 0.80 58 5.3 22 10256 0.7 2.1 74.9 5080 77
900 AMA 500L8W 186 745 95.8 96.0 0.84 0.80 65 5.3 24 11539 0.7 2.0 79.3 5230 77
1000 AMA 500L8W 187 745 95.9 96.1 0.83 0.79 72 5.4 28 12819 0.7 2.0 83.6 5380 77
1120 AMA 500L8W 490 745 96.1 96.3 0.84 0.81 80 5.3 30 14359 0.7 2.0 92.3 5670 77
1250 AMA 500L8W

600 r/min = 10 poles


491 744 96.0 96.3 0.85 0.83

10000 V 50 Hz
88 5.3 29 16040 0.8 1.9 93.0 5680 77
2
500 AMA 500L10W 188 594 94.4 94.6 0.82 0.78 37 5.4 16 8034 0.8 2.2 66.1 4750 77
560 AMA 500L10W 189 594 94.6 94.8 0.83 0.79 41 5.2 17 9002 0.8 2.1 70.4 4900 77
630 AMA 500L10W 190 594 94.7 95.0 0.83 0.80 46 5.1 18 10131 0.8 2.0 74.7 5050 77
710 AMA 500L10W 191 595 94.9 95.2 0.83 0.79 52 5.1 21 11404 0.7 2.1 79.9 5200 77
800 AMA 500L10W 492 595 95.0 95.3 0.83 0.79 59 5.1 24 12850 0.7 2.1 84.2 5350 77

500 r/min = 12 poles 10000 V 50 Hz


355 AMA 500L12W 192 494 93.3 93.7 0.79 0.74 28 4.2 13 6865 0.6 1.9 61.7 4620 77
400 AMA 500L12W 193 494 93.6 93.9 0.78 0.74 31 4.3 14 7733 0.6 1.9 66.0 4760 77
450 AMA 500L12W 194 494 93.8 94.0 0.77 0.72 36 4.5 17 8693 0.7 2.0 70.4 4910 77
500 AMA 500L12W 195 495 94.0 94.1 0.77 0.72 40 4.7 20 9654 0.7 2.1 79.1 5180 77
560 AMA 500L12W 196 494 94.1 94.2 0.78 0.72 44 4.6 21 10815 0.7 2.0 83.4 5330 77
630 AMA 500L12W 495 494 94.2 94.4 0.78 0.72 50 4.6 24 12169 0.7 2.0 87.7 5470 77

Data presented in rating lists are typical values.


Guaranteed values on request. All engineered motors
are optimized for the specified application. Accurate
motor data will be given on request at quotation phase.
Legally binding performance and specification data is
given to the end user once each order is confirmed.

ABB/ BU Machines / HV Induction motors IEC catalogue / Engineered motors EN 05-2006 91


HV Modular motors 3000 V - 50 Hz
Technical data for totally enclosed squirrel
cage three phase motors
IP 55 - IC 81W - Insulation class F, temperature rise class B

Efficiency Power factor Current Torque Sound


Full 3/4 Full 3/4 IN IS I0 TN TS Tmax Rotor Motor pressure
Output Motor Product Speed load load load load inertia weight level LP
kW type ID r/min 100% 75% 100% 75% A IN A Nm TN TN kgm2 kg dB(A)

3000 r/min = 2 poles 3000 V 50 Hz


710 AMA 400L2L 1001 2973 95.9 96.1 0.86 0.84 166 4.8 45 2280 0.5 2.1 6.0 2880 75
800 AMA 400L2L 1002 2974 96.1 96.3 0.87 0.86 184 4.9 45 2569 0.5 2.1 6.5 2980 75
900 AMA 400L2L 1003 2974 96.2 96.4 0.88 0.87 204 4.9 47 2890 0.5 2.1 7.0 3070 75
1000 AMA 400L2L 1004 2977 96.4 96.6 0.88 0.87 226 5.1 53 3208 0.5 2.1 7.3 3190 75
1120 AMA 400L2L 1005 2976 96.5 96.7 0.88 0.87 253 5.3 60 3594 0.6 2.2 7.9 3310 75
1250 AMA 450L2L 1006 2977 96.6 96.7 0.88 0.86 284 4.8 69 4010 0.5 2.0 12.0 4080 76
1400 AMA 450L2L 1007 2978 96.7 96.9 0.86 0.85 324 4.8 84 4489 0.5 2.0 12.7 4220 76
1600 AMA 450L2L 1008 2979 96.9 97.1 0.87 0.85 367 5.0 92 5129 0.5 2.1 14.2 4520 76
1800 AMA 500L2L 1009 2986 97.0 97.0 0.85 0.82 421 5.3 140 5756 0.4 2.2 19.6 5110 77
2000 AMA 500L2L 1010 2984 97.0 97.1 0.88 0.87 448 5.1 112 6401 0.4 2.1 21.0 5300 77
2240 AMA 500L2L 1011 2987 97.3 97.2 0.84 0.81 527 5.7 183 7162 0.5 2.4 22.3 5500 77
2500 AMA 500L2L 1168 2984 97.3 97.4 0.89 0.88 554 5.2 126 8000 0.5 2.1 25.0 5880 77

1500 r/min = 4 poles 3000 V 50 Hz


710 AMA 400L4L 1012 1488 95.8 95.9 0.80 0.75 178 5.3 79 4556 0.7 2.3 13.8 2850 74
800 AMA 400L4L 1013 1488 96.0 96.1 0.81 0.77 197 5.3 82 5134 0.7 2.2 14.8 2960 74
900 AMA 400L4L 1014 1488 96.2 96.3 0.81 0.77 221 5.4 91 5776 0.7 2.3 15.8 3070 74

2 1000
1120
AMA 400L4L
AMA 400L4L
1015
1016
1487
1487
96.2
96.3
96.4
96.5
0.85
0.84
0.83
0.81
235 5.0
265 5.3
78
94
6423
7192
0.6
0.7
2.0
2.1
16.8
17.7
3160
3260
74
74
1250 AMA 400L4L 1017 1487 96.4 96.6 0.83 0.80 299 5.3 108 8025 0.7 2.2 18.7 3370 74
1400 AMA 450L4L 1018 1486 96.2 96.5 0.87 0.86 321 4.9 85 8996 0.6 1.9 29.1 4000 75
1600 AMA 450L4L 1019 1486 96.4 96.7 0.88 0.88 361 5.0 86 10281 0.7 1.9 32.5 4260 75
1800 AMA 450L4L 1020 1487 96.6 96.9 0.89 0.88 404 5.3 99 11559 0.7 2.0 35.9 4520 75
2000 AMA 500L4L 1021 1490 96.6 96.8 0.89 0.88 450 4.9 106 12822 0.6 1.8 52.7 5330 75
2240 AMA 500L4L 1022 1490 96.7 96.9 0.88 0.88 505 4.9 121 14360 0.6 1.8 55.6 5490 75
2500 AMA 500L4L 1023 1490 96.8 97.0 0.89 0.88 559 5.3 133 16020 0.7 1.9 61.6 5790 75
2800 AMA 500L4L 1157 1490 97.0 97.2 0.89 0.89 621 5.5 142 17940 0.7 2.0 67.5 6140 75

Data presented in rating lists are typical values.


Guaranteed values on request. All engineered motors
are optimized for the specified application. Accurate
motor data will be given on request at quotation phase.
Legally binding performance and specification data is
given to the end user once each order is confirmed.

92 ABB/ BU Machines / HV Induction motors IEC catalogue / Engineered motors EN 05-2006


HV Modular motors 3000 V - 50 Hz
Technical data for totally enclosed squirrel
cage three phase motors
IP 55 - IC 81W - Insulation class F, temperature rise class B
Efficiency Power factor Current Torque Sound
Full 3/4 Full 3/4 IN IS I0 TN TS Tmax Rotor Motor pressure
Output Motor Product Speed load load load load inertia weight level LP
kW type ID r/min 100% 75% 100% 75% A IN A Nm TN TN kgm2 kg dB(A)

1000 r/min = 6 poles 3000 V 50 Hz


500 AMA 400L6L 1024 986 95.1 95.5 0.84 0.82 120 4.4 40 4842 0.7 1.7 15.3 2780 73
560 AMA 400L6L 1025 987 95.4 95.6 0.83 0.80 135 4.8 49 5416 0.7 1.9 16.5 2880 73
630 AMA 400L6L 1026 987 95.3 95.7 0.84 0.82 151 4.6 50 6096 0.7 1.8 17.7 2960 73
710 AMA 400L6L 1027 988 95.6 95.9 0.84 0.81 169 5.0 59 6861 0.8 1.9 20.1 3150 73
800 AMA 400L6L 1028 988 95.7 96.0 0.84 0.81 192 5.1 69 7730 0.8 2.0 21.2 3250 73
900 AMA 400L6L 1029 988 95.8 96.1 0.85 0.82 213 5.1 71 8697 0.8 1.9 23.6 3440 73
1000 AMA 450L6L 1030 992 96.3 96.4 0.81 0.77 245 5.3 101 9626 0.7 2.1 36.8 4020 74
1120 AMA 450L6L 1031 991 96.3 96.6 0.86 0.84 260 5.1 81 10796 0.7 2.0 39.4 4140 74
1250 AMA 450L6L 1032 990 96.2 96.6 0.87 0.85 289 4.8 80 12059 0.6 1.8 41.6 4250 74
1400 AMA 450L6L 1033 990 96.3 96.7 0.87 0.86 322 5.0 89 13502 0.7 1.9 46.0 4490 74
1600 AMA 500L6L 1034 991 96.5 96.8 0.88 0.87 362 5.1 94 15419 0.7 1.9 64.4 5300 74
1800 AMA 500L6L 1035 992 96.6 96.9 0.88 0.86 408 5.5 112 17334 0.8 2.0 71.5 5570 74
2000 AMA 500L6L 1158 991 96.7 97.0 0.89 0.88 447 5.3 105 19272 0.8 1.9 78.8 5890 74
2250 AMA 500L6L 1159 991 96.8 97.1 0.89 0.88 503 5.4 121 21674 0.8 2.0 86.0 6190 74

750 r/min = 8 poles 3000 V 50 Hz


315 AMA 400L8L 1036 738 94.5 94.9 0.83 0.80 77 4.4 27 4076 0.8 1.8 17.1 2730 73
355
400
AMA 400L8L
AMA 400L8L
1037
1038
739
739
94.6
94.9
95.0
95.3
0.83
0.83
0.80
0.80
87
97
4.6 32
4.6 35
4585
5166
0.8
0.8
1.8
1.9
18.6
20.0
2830
2930
73
73
2
450 AMA 400L8L 1039 739 95.1 95.4 0.84 0.81 109 4.5 37 5814 0.8 1.8 21.4 3040 73
500 AMA 400L8L 1040 739 95.1 95.4 0.84 0.81 121 4.5 41 6460 0.8 1.8 22.8 3120 73
560 AMA 400L8L 1041 739 95.2 95.5 0.84 0.81 135 4.6 47 7233 0.8 1.8 24.2 3220 73
630 AMA 400L8L 1042 739 95.2 95.6 0.84 0.82 151 4.5 50 8140 0.8 1.8 26.9 3400 73
710 AMA 450L8L 1043 742 95.8 96.0 0.83 0.79 172 5.1 66 9138 0.8 2.0 39.9 3850 73
800 AMA 450L8L 1044 741 95.8 96.2 0.85 0.84 188 4.6 58 10311 0.7 1.8 45.2 4090 73
900 AMA 450L8L 1045 741 95.8 96.3 0.86 0.84 211 4.6 63 11598 0.7 1.8 50.4 4310 73
1000 AMA 450L8L 1046 743 96.2 96.4 0.83 0.79 240 5.5 93 12854 0.8 2.1 55.5 4550 73
1120 AMA 500L8L 1047 739 95.8 96.4 0.87 0.86 258 4.3 66 14464 0.6 1.7 74.1 5240 73
1250 AMA 500L8L 1048 741 96.2 96.6 0.87 0.86 288 4.6 76 16105 0.7 1.7 83.3 5550 73
1400 AMA 500L8L 1049 742 96.4 96.7 0.86 0.85 323 5.1 96 18016 0.7 1.9 91.9 5830 73
1600 AMA 500L8L 1160 742 96.3 96.7 0.87 0.86 368 4.8 101 20602 0.7 1.8 100.6 6140 73

Data presented in rating lists are typical values.


Guaranteed values on request. All engineered motors
are optimized for the specified application. Accurate
motor data will be given on request at quotation phase.
Legally binding performance and specification data is
given to the end user once each order is confirmed.

ABB/ BU Machines / HV Induction motors IEC catalogue / Engineered motors EN 05-2006 93


HV Modular motors 3000 V - 50 Hz
Technical data for totally enclosed squirrel
cage three phase motors
IP 55 - IC 81W - Insulation class F, temperature rise class B

Efficiency Power factor Current Torque Sound


Full 3/4 Full 3/4 IN IS I0 TN TS Tmax Rotor Motor pressure
Output Motor Product Speed load load load load inertia weight level LP
kW type ID r/min 100% 75% 100% 75% A IN A Nm TN TN kgm2 kg dB(A)

600 r/min = 10 poles 3000 V 50 Hz


224 AMA 400L10L 1050 591 93.6 93.8 0.75 0.70 61 4.0 30 3621 0.7 1.8 15.9 2660 73
250 AMA 400L10L 1051 590 93.8 94.0 0.76 0.71 67 4.0 31 4043 0.7 1.7 17.3 2750 73
280 AMA 400L10L 1052 590 93.9 94.2 0.77 0.72 75 3.9 34 4528 0.7 1.7 18.7 2850 73
315 AMA 400L10L 1053 591 94.0 94.3 0.77 0.72 84 4.0 38 5093 0.7 1.7 20.1 2940 73
355 AMA 400L10L 1054 592 94.3 94.4 0.75 0.70 96 4.3 46 5725 0.8 1.8 22.9 3120 73
400 AMA 400L10L 1055 592 94.5 94.7 0.76 0.71 107 4.1 49 6455 0.7 1.7 24.3 3240 73
450 AMA 400L10L 1056 592 94.7 94.7 0.75 0.70 122 4.4 60 7253 0.8 1.9 27.1 3430 73
500 AMA 450L10L 1057 591 94.8 95.3 0.82 0.79 124 4.2 45 8074 0.7 1.7 39.7 3840 73
560 AMA 450L10L 1058 592 95.0 95.4 0.82 0.79 139 4.3 53 9038 0.7 1.8 42.3 3960 73
630 AMA 450L10L 1059 592 95.1 95.5 0.82 0.79 155 4.3 57 10167 0.7 1.8 47.5 4200 73
710 AMA 450L10L 1060 592 95.2 95.6 0.83 0.80 173 4.2 60 11459 0.7 1.7 55.3 4560 73
800 AMA 500L10L 1061 594 95.8 96.0 0.82 0.78 197 4.9 79 12857 0.7 2.0 75.2 5200 73
900 AMA 500L10L 1062 593 95.9 96.2 0.84 0.81 216 4.6 75 14484 0.6 1.8 79.8 5390 73
1000 AMA 500L10L 1063 594 96.0 96.2 0.84 0.81 239 4.8 84 16083 0.7 1.9 93.0 5810 73
1120 AMA 500L10L 1161 594 96.1 96.3 0.83 0.79 271 5.0 104 17997 0.7 2.0 101.4 6110 73

500 r/min = 12 poles 3000 V 50 Hz

2 160
180
AMA 400L12L 1064
AMA 400L12L 1065
491
492
92.5
92.8
92.5
92.8
0.73
0.73
0.67
0.68
46
51
3.8 23
3.8 25
3110
3495
0.8
0.8
1.7
1.7
17.3
18.8
2740
2840
73
73
200 AMA 400L12L 1066 492 92.9 93.0 0.74 0.68 56 3.8 28 3883 0.8 1.7 20.2 2940 73
224 AMA 400L12L 1067 492 93.1 93.1 0.73 0.68 63 3.9 32 4347 0.8 1.7 21.6 3030 73
250 AMA 400L12L 1068 493 93.3 93.2 0.72 0.66 72 4.1 38 4846 0.9 1.8 23.0 3130 73
280 AMA 400L12L 1069 492 93.1 93.2 0.73 0.68 79 3.8 40 5433 0.8 1.7 24.4 3210 73
315 AMA 400L12L 1070 493 93.4 93.3 0.72 0.67 90 4.0 47 6106 0.8 1.8 27.2 3400 73
355 AMA 450L12L 1071 494 94.5 94.5 0.73 0.68 98 4.2 51 6866 0.7 1.9 39.8 3820 73
400 AMA 450L12L 1072 494 94.6 94.7 0.73 0.67 111 4.2 58 7736 0.7 1.9 42.4 3940 73
450 AMA 450L12L 1073 494 94.7 94.8 0.75 0.69 122 4.1 60 8707 0.7 1.8 47.6 4180 73
500 AMA 450L12L 1074 493 94.5 94.8 0.76 0.71 135 3.9 63 9681 0.7 1.7 50.2 4270 73
560 AMA 450L12L 1075 493 94.7 94.9 0.75 0.70 151 4.0 73 10837 0.7 1.8 55.5 4520 73
630 AMA 500L12L 1076 493 95.0 95.3 0.78 0.74 164 3.9 71 12198 0.6 1.7 74.7 5190 73
710 AMA 500L12L 1077 493 95.2 95.4 0.78 0.74 184 4.0 79 13743 0.6 1.7 83.4 5500 73
800 AMA 500L12L 1078 493 95.3 95.5 0.78 0.74 206 3.9 86 15494 0.6 1.7 87.7 5680 73
900 AMA 500L12L 1170 493 95.4 95.6 0.78 0.74 232 4.1 100 17416 0.6 1.8 100.8 6100 73

Data presented in rating lists are typical values.


Guaranteed values on request. All engineered motors
are optimized for the specified application. Accurate
motor data will be given on request at quotation phase.
Legally binding performance and specification data is
given to the end user once each order is confirmed.

94 ABB/ BU Machines / HV Induction motors IEC catalogue / Engineered motors EN 05-2006


HV Modular motors 6000 V - 50 Hz
Technical data for totally enclosed squirrel
cage three phase motors
IP 55 - IC 81W - Insulation class F, temperature rise class B

Efficiency Power factor Current Torque Sound


Full 3/4 Full 3/4 IN IS I0 TN TS Tmax Rotor Motor pressure
Output Motor Product Speed load load load load inertia weight level LP
kW type ID r/min 100% 75% 100% 75% A IN A Nm TN TN kgm2 kg dB(A)

3000 r/min = 2 poles 6000 V 50 Hz


710 AMA 400L2L 1 2973 95.6 95.8 0.86 0.84 83 4.7 22 2281 0.5 2.0 6.0 2820 75
800 AMA 400L2L 2 2974 95.8 96.0 0.87 0.86 92 4.9 23 2569 0.5 2.1 6.5 2920 75
900 AMA 400L2L 3 2974 96.0 96.3 0.88 0.87 102 4.9 23 2890 0.5 2.1 7.0 3030 75
1000 AMA 400L2L 4 2977 96.2 96.5 0.88 0.87 113 5.1 26 3208 0.5 2.1 7.3 3140 75
1120 AMA 400L2L 5 2976 96.3 96.6 0.88 0.87 127 5.3 30 3594 0.6 2.2 7.9 3260 75
1250 AMA 450L2L 6 2977 96.5 96.6 0.88 0.86 142 4.8 34 4010 0.5 2.0 12.0 4020 76
1400 AMA 450L2L 7 2978 96.6 96.8 0.86 0.85 162 4.8 42 4489 0.5 2.1 12.7 4170 76
1600 AMA 450L2L 8 2979 96.8 97.0 0.87 0.86 184 5.0 46 5129 0.5 2.1 14.2 4460 76
1800 AMA 500L2L 9 2984 96.8 96.9 0.88 0.87 203 5.1 52 5761 0.4 2.1 19.7 5030 77
2000 AMA 500L2L 10 2984 97.0 97.1 0.89 0.87 224 5.2 56 6401 0.4 2.1 21.0 5230 77
2240 AMA 500L2L 11 2984 97.1 97.2 0.89 0.87 250 5.3 63 7168 0.5 2.2 22.3 5420 77
2500 AMA 500L2L 578 2984 97.2 97.3 0.89 0.88 277 5.3 63 8000 0.5 2.1 25.0 5790 77

1500 r/min = 4 poles 6000 V 50 Hz


710 AMA 400L4L 12 1486 95.5 95.8 0.86 0.83 83 5.0 28 4562 0.6 2.0 13.9 2810 74
800 AMA 400L4L 13 1486 95.7 96.0 0.87 0.85 93 5.0 28 5142 0.6 2.0 14.9 2910 74
900 AMA 400L4L 14 1486 95.8 96.2 0.87 0.85 103 5.0 30 5785 0.6 2.0 15.9 3010 74
1000
1120
AMA 400L4L
AMA 400L4L
15
16
1484
1484
95.7
95.8
96.2
96.3
0.89
0.89
0.89
0.88
113 4.7 26
126 4.8 30
6435
7206
0.6
0.6
1.9
1.9
16.9
17.9
3100
3200
74
74
2
1250 AMA 450L4L 17 1487 95.9 96.2 0.86 0.84 145 5.0 43 8029 0.6 1.9 27.3 3810 75
1400 AMA 450L4L 18 1486 96.1 96.4 0.87 0.86 160 5.0 42 8996 0.7 1.9 29.1 3940 75
1600 AMA 450L4L 19 1486 96.3 96.6 0.89 0.88 180 5.1 43 10281 0.7 1.9 32.5 4210 75
1800 AMA 500L4L 20 1489 96.3 96.5 0.89 0.88 203 5.0 49 11540 0.6 1.8 49.8 5070 75
2000 AMA 500L4L 21 1490 96.4 96.6 0.89 0.88 225 5.0 53 12822 0.6 1.8 52.7 5230 75
2240 AMA 500L4L 22 1490 96.5 96.8 0.89 0.88 252 5.1 60 14359 0.6 1.8 55.6 5390 75
2500 AMA 500L4L 23 1490 96.7 97.0 0.89 0.88 281 5.3 68 16021 0.7 1.9 61.2 5710 75
2800 AMA 500L4L 472 1490 96.9 97.1 0.89 0.88 312 5.5 73 17941 0.7 2.0 67.2 6020 75

Data presented in rating lists are typical values.


Guaranteed values on request. All engineered motors
are optimized for the specified application. Accurate
motor data will be given on request at quotation phase.
Legally binding performance and specification data is
given to the end user once each order is confirmed.

ABB/ BU Machines / HV Induction motors IEC catalogue / Engineered motors EN 05-2006 95


HV Modular motors 6000 V - 50 Hz
Technical data for totally enclosed squirrel
cage three phase motors
IP 55 - IC 81W - Insulation class F, temperature rise class B

Efficiency Power factor Current Torque Sound


Full 3/4 Full 3/4 IN IS I0 TN TS Tmax Rotor Motor pressure
Output Motor Product Speed load load load load inertia weight level LP
kW type ID r/min 100% 75% 100% 75% A IN A Nm TN TN kgm2 kg dB(A)

1000 r/min = 6 poles 6000 V 50 Hz


500 AMA 400L6L 24 986 94.8 95.2 0.85 0.82 60 4.5 20 4842 0.7 1.7 15.3 2730 73
560 AMA 400L6L 25 987 95.0 95.3 0.84 0.81 68 4.9 25 5416 0.8 1.9 16.5 2810 73
630 AMA 400L6L 26 987 95.1 95.5 0.85 0.82 75 4.7 25 6096 0.7 1.8 17.7 2910 73
710 AMA 400L6L 27 988 95.4 95.7 0.85 0.82 85 5.1 30 6861 0.8 1.9 20.1 3100 73
800 AMA 400L6L 28 988 95.5 95.8 0.84 0.81 96 5.2 35 7730 0.9 2.0 21.2 3190 73
900 AMA 450L6L 29 991 95.8 96.1 0.86 0.83 106 5.2 35 8674 0.7 2.0 35.0 3830 74
1000 AMA 450L6L 30 990 96.0 96.4 0.87 0.85 115 5.0 34 9643 0.7 1.9 37.2 3950 74
1120 AMA 450L6L 31 991 96.2 96.5 0.86 0.84 130 5.2 40 10796 0.7 2.0 39.4 4080 74
1250 AMA 450L6L 32 990 96.1 96.5 0.87 0.85 144 4.9 40 12059 0.7 1.9 41.6 4190 74
1400 AMA 450L6L 33 990 96.2 96.6 0.87 0.86 161 5.0 45 13502 0.7 1.9 46.0 4430 74
1600 AMA 500L6L 34 991 96.3 96.7 0.88 0.87 181 5.2 47 15419 0.7 1.9 64.4 5210 74
1800 AMA 500L6L 35 991 96.4 96.8 0.89 0.88 203 5.2 50 17344 0.7 1.9 71.5 5500 74
2000 AMA 500L6L 473 991 96.5 96.9 0.89 0.88 224 5.2 53 19272 0.7 1.9 78.6 5800 74
2250 AMA 500L6L 474 991 96.6 97.0 0.89 0.89 252 5.3 59 21679 0.8 1.9 85.8 6100 74

750 r/min = 8 poles 6000 V 50 Hz


315 AMA 400L8L 36 739 94.0 94.5 0.83 0.80 39 4.5 14 4071 0.8 1.8 17.2 2700 73

2 355
400
AMA 400L8L
AMA 400L8L
37
38
739
739
94.0
94.4
94.5
94.9
0.83
0.84
0.80
0.81
44
49
4.5 16
4.6 17
4586
5167
0.8
0.8
1.8
1.8
18.6
20.0
2790
2880
73
73
450 AMA 400L8L 39 739 94.5 95.0 0.84 0.81 55 4.4 19 5815 0.8 1.8 21.4 2980 73
500 AMA 400L8L 40 739 94.6 95.1 0.84 0.81 61 4.5 21 6461 0.8 1.8 22.8 3070 73
560 AMA 400L8L 41 739 94.7 95.2 0.84 0.81 68 4.5 24 7234 0.8 1.8 24.2 3170 73
630 AMA 450L8L 42 742 95.3 95.7 0.83 0.80 76 5.1 29 8109 0.8 2.0 37.3 3670 73
710 AMA 450L8L 43 742 95.4 95.8 0.83 0.80 86 5.1 33 9138 0.8 2.0 39.9 3800 73
800 AMA 450L8L 44 741 95.5 96.0 0.85 0.84 94 4.6 29 10311 0.7 1.7 45.2 4030 73
900 AMA 450L8L 45 741 95.7 96.1 0.86 0.84 106 4.6 32 11598 0.7 1.8 50.4 4280 73
1000 AMA 500L8L 46 739 95.5 96.1 0.87 0.85 116 4.4 32 12915 0.6 1.7 65.5 4870 73
1120 AMA 500L8L 47 739 95.6 96.2 0.87 0.86 129 4.3 33 14465 0.6 1.7 74.1 5170 73
1250 AMA 500L8L 48 741 95.9 96.4 0.87 0.86 144 4.6 38 16102 0.6 1.7 83.4 5440 73
1400 AMA 500L8L 49 742 96.2 96.5 0.87 0.85 162 5.1 48 18012 0.7 1.9 92.1 5750 73
1600 AMA 500L8L 475 742 96.2 96.6 0.87 0.86 184 4.9 51 20597 0.7 1.8 100.7 6040 73

Data presented in rating lists are typical values.


Guaranteed values on request. All engineered motors
are optimized for the specified application. Accurate
motor data will be given on request at quotation phase.
Legally binding performance and specification data is
given to the end user once each order is confirmed.

96 ABB/ BU Machines / HV Induction motors IEC catalogue / Engineered motors EN 05-2006


HV Modular motors 6000 V - 50 Hz
Technical data for totally enclosed squirrel
cage three phase motors
IP 55 - IC 81W - Insulation class F, temperature rise class B
Efficiency Power factor Current Torque Sound
Full 3/4 Full 3/4 IN IS I0 TN TS Tmax Rotor Motor pressure
Output Motor Product Speed load load load load inertia weight level LP
kW type ID r/min 100% 75% 100% 75% A IN A Nm TN TN kgm2 kg dB(A)

600 r/min = 10 poles 6000 V 50 Hz


224 AMA 400L10L 50 591 92.9 93.2 0.75 0.70 31 4.0 15 3622 0.7 1.8 15.9 2620 73
250 AMA 400L10L 51 590 93.0 93.4 0.77 0.72 34 3.9 16 4044 0.6 1.7 17.3 2710 73
280 AMA 400L10L 52 590 93.2 93.7 0.77 0.73 37 3.9 17 4529 0.6 1.7 18.7 2800 73
315 AMA 400L10L 53 591 93.5 93.9 0.77 0.72 42 3.9 19 5094 0.7 1.7 20.1 2900 73
355 AMA 400L10L 54 592 93.8 94.0 0.76 0.70 48 4.3 23 5726 0.8 1.8 22.9 3070 73
400 AMA 400L10L 55 592 93.9 94.1 0.76 0.72 54 4.1 25 6456 0.7 1.7 24.3 3170 73
450 AMA 450L10L 56 591 94.2 94.8 0.82 0.79 56 4.1 20 7269 0.7 1.7 37.0 3650 73
500 AMA 450L10L 57 591 94.4 94.9 0.82 0.79 62 4.2 23 8074 0.7 1.7 39.7 3770 73
560 AMA 450L10L 58 592 94.5 95.0 0.82 0.79 69 4.3 26 9039 0.7 1.7 42.3 3890 73
630 AMA 450L10L 59 592 94.7 95.2 0.82 0.79 78 4.3 28 10168 0.7 1.7 47.5 4130 73
710 AMA 500L10L 60 594 95.4 95.7 0.83 0.79 87 4.8 34 11415 0.7 1.9 71.0 4980 73
800 AMA 500L10L 61 594 95.4 95.8 0.83 0.80 97 4.7 35 12869 0.7 1.9 75.4 5130 73
900 AMA 500L10L 62 593 95.6 96.0 0.84 0.81 108 4.5 38 14484 0.6 1.8 79.8 5320 73
1000 AMA 500L10L 63 594 95.8 96.1 0.84 0.81 119 4.7 42 16083 0.7 1.9 93.0 5760 73
1120 AMA 500L10L 476 594 95.7 96.1 0.85 0.82 133 4.6 44 18020 0.7 1.8 101.7 6030 73

500 r/min = 12 poles 6000 V 50 Hz


160
180
AMA 400L12L
AMA 400L12L
64
65
492
492
91.6
91.8
91.8
92.0
0.73
0.74
0.68
0.69
23
25
3.8 12
3.7 13
3106
3496
0.8
0.7
1.7
1.7
17.4
18.8
2700
2790
73
73
2
200 AMA 400L12L 66 492 92.0 92.2 0.74 0.69 28 3.7 14 3884 0.7 1.7 20.2 2890 73
224 AMA 400L12L 67 492 92.3 92.4 0.74 0.68 32 3.8 16 4348 0.8 1.7 21.6 2980 73
250 AMA 400L12L 68 492 92.3 92.3 0.73 0.67 36 4.0 19 4848 0.8 1.8 23.0 3060 73
280 AMA 400L12L 69 492 92.4 92.5 0.73 0.68 40 3.8 20 5434 0.8 1.7 24.4 3160 73
315 AMA 450L12L 70 494 93.8 93.9 0.73 0.67 44 4.3 24 6091 0.8 2.0 37.1 3640 73
355 AMA 450L12L 71 494 93.9 94.0 0.74 0.68 49 4.3 26 6866 0.8 1.9 39.8 3760 73
400 AMA 450L12L 72 494 94.1 94.2 0.74 0.68 55 4.3 29 7736 0.8 1.9 42.4 3880 73
450 AMA 450L12L 73 494 94.2 94.4 0.75 0.70 61 4.2 30 8706 0.7 1.8 47.6 4120 73
500 AMA 450L12L 74 493 93.9 94.2 0.76 0.71 67 4.0 32 9681 0.7 1.7 50.2 4200 73
560 AMA 500L12L 75 494 94.6 94.8 0.77 0.72 74 4.2 35 10831 0.6 1.9 70.3 4960 73
630 AMA 500L12L 76 493 94.6 94.9 0.78 0.74 82 4.1 36 12197 0.6 1.8 74.7 5110 73
710 AMA 500L12L 77 493 94.8 95.1 0.79 0.74 92 4.1 40 13741 0.6 1.8 83.4 5410 73
800 AMA 500L12L 78 493 95.0 95.3 0.79 0.75 103 4.0 43 15491 0.6 1.7 87.7 5600 73
900 AMA 500L12L 580 494 95.2 95.4 0.79 0.74 116 4.2 50 17414 0.6 1.8 100.8 6040 73

Data presented in rating lists are typical values.


Guaranteed values on request. All engineered motors
are optimized for the specified application. Accurate
motor data will be given on request at quotation phase.
Legally binding performance and specification data is
given to the end user once each order is confirmed.

ABB/ BU Machines / HV Induction motors IEC catalogue / Engineered motors EN 05-2006 97


HV Modular motors 10000 V - 50 Hz
Technical data for totally enclosed squirrel
cage three phase motors
IP 55 - IC 81W - Insulation class F, temperature rise class B

Efficiency Power factor Current Torque Sound


Full 3/4 Full 3/4 IN IS I0 TN TS Tmax Rotor Motor pressure
Output Motor Product Speed load load load load inertia weight level LP
kW type ID r/min 100% 75% 100% 75% A IN A Nm TN TN kgm2 kg dB(A)

3000 r/min = 2 poles 10000 V 50 Hz


630 AMA 450L2L 157 2980 95.2 95.1 0.84 0.81 45 5.1 15 2019 0.4 2.3 9.1 3370 76
710 AMA 450L2L 158 2980 95.5 95.5 0.86 0.83 50 5.3 16 2275 0.5 2.3 9.8 3520 76
800 AMA 450L2L 159 2981 95.8 95.8 0.86 0.83 56 5.3 17 2563 0.5 2.3 10.6 3660 76
900 AMA 450L2L 160 2980 95.8 96.0 0.88 0.86 62 5.2 16 2884 0.5 2.2 11.4 3790 76
1000 AMA 450L2L 161 2979 96.1 96.2 0.88 0.87 68 5.1 16 3206 0.5 2.2 12.1 3950 76
1120 AMA 500L2L 162 2985 96.0 95.9 0.87 0.84 78 5.3 23 3583 0.4 2.2 17.3 4580 77
1250 AMA 500L2L 163 2985 96.2 96.2 0.87 0.86 86 5.3 24 3999 0.4 2.2 18.7 4770 77
1400 AMA 500L2L 164 2985 96.4 96.4 0.88 0.86 96 5.4 26 4479 0.5 2.2 20.0 4960 77
1600 AMA 500L2L 165 2984 96.5 96.6 0.89 0.89 107 5.2 24 5120 0.5 2.1 21.4 5160 77
1800 AMA 500L2L 485 2985 96.7 96.8 0.89 0.88 120 5.4 28 5759 0.5 2.2 22.4 5340 77

1500 r/min = 4 poles 10000 V 50 Hz


710 AMA 450L4L 166 1489 95.0 95.0 0.85 0.82 51 5.4 18 4554 0.6 2.1 22.2 3380 75
800 AMA 450L4L 167 1489 95.3 95.4 0.86 0.83 56 5.5 19 5131 0.7 2.1 23.9 3510 75
900 AMA 450L4L 168 1489 95.5 95.6 0.86 0.83 63 5.5 21 5771 0.7 2.1 25.5 3630 75
1000 AMA 450L4L 169 1489 95.7 95.8 0.86 0.84 70 5.6 23 6412 0.7 2.1 27.3 3770 75
1120 AMA 500L4L 170 1491 95.4 95.4 0.88 0.86 77 5.5 22 7172 0.5 2.2 43.6 4670 75

2 1250
1400
AMA 500L4L
AMA 500L4L
171
172
1491
1491
95.8
96.0
95.9
96.1
0.89
0.89
0.87
0.87
85
95
5.6 24
5.6 26
8004
8964
0.5
0.6
2.1
2.1
46.2
49.0
4840
4990
75
75
1600 AMA 500L4L 173 1491 96.2 96.3 0.88 0.86 109 5.4 31 10245 0.5 2.0 51.7 5150 75
1800 AMA 500L4L 174 1489 96.2 96.3 0.88 0.87 123 5.5 33 11544 0.7 2.1 54.1 5310 75
2000 AMA 500L4L 486 1491 96.4 96.5 0.87 0.85 138 6.0 43 12810 0.7 2.3 57.2 5460 75
2240 AMA 500L4L 487 1490 96.3 96.5 0.88 0.86 152 5.6 42 14359 0.7 2.2 57.6 5460 75

Data presented in rating lists are typical values.


Guaranteed values on request. All engineered motors
are optimized for the specified application. Accurate
motor data will be given on request at quotation phase.
Legally binding performance and specification data is
given to the end user once each order is confirmed.

98 ABB/ BU Machines / HV Induction motors IEC catalogue / Engineered motors EN 05-2006


HV Modular motors 10000 V - 50 Hz
Technical data for totally enclosed squirrel
cage three phase motors
IP 55 - IC 81W - Insulation class F, temperature rise class B
Efficiency Power factor Current Torque Sound
Full 3/4 Full 3/4 IN IS I0 TN TS Tmax Rotor Motor pressure
Output Motor Product Speed load load load load inertia weight level LP
kW type ID r/min 100% 75% 100% 75% A IN A Nm TN TN kgm2 kg dB(A)

1000 r/min = 6 poles 10000 V 50 Hz


560 AMA 450L6L 176 991 95.2 95.4 0.85 0.82 40 5.6 14 5396 0.7 2.2 30.3 3530 74
630 AMA 450L6L 177 991 95.4 95.6 0.86 0.82 45 5.6 16 6071 0.7 2.1 32.4 3650 74
710 AMA 450L6L 178 991 95.6 95.8 0.85 0.82 50 5.7 18 6840 0.7 2.1 34.5 3770 74
800 AMA 450L6L 179 990 95.5 95.8 0.86 0.84 56 5.4 18 7716 0.7 2.0 34.7 3770 74
900 AMA 450L6L 180 991 95.7 95.9 0.85 0.82 64 5.6 23 8676 0.8 2.1 36.8 3880 74
1000 AMA 500L6L 181 994 95.9 96.1 0.87 0.85 69 5.4 21 9611 0.6 2.1 60.7 4970 74
1120 AMA 500L6L 182 994 96.0 96.3 0.87 0.85 77 5.4 24 10763 0.6 2.0 64.1 5120 74
1250 AMA 500L6L 183 993 96.1 96.3 0.87 0.85 86 5.4 27 12018 0.6 2.0 66.9 5260 74
1400 AMA 500L6L 488 993 96.2 96.5 0.87 0.85 97 5.4 30 13460 0.6 2.0 70.5 5420 74
1600 AMA 500L6L 489 993 96.4 96.6 0.87 0.85 110 5.4 34 15382 0.7 2.0 77.5 5710 74

750 r/min = 8 poles 10000 V 50 Hz


710 AMA 500L8L 184 744 95.5 95.7 0.84 0.81 51 5.4 19 9110 0.7 2.0 62.5 4670 73
800 AMA 500L8L 185 745 95.7 95.9 0.84 0.80 58 5.3 22 10256 0.7 2.1 74.9 5080 73
900 AMA 500L8L 186 745 95.8 96.0 0.84 0.80 65 5.3 24 11539 0.7 2.0 79.3 5230 73
1000 AMA 500L8L 187 745 95.9 96.1 0.83 0.79 72 5.4 28 12819 0.7 2.0 83.6 5380 73
1120 AMA 500L8L 490 745 96.1 96.3 0.84 0.81 80 5.3 30 14359 0.7 2.0 92.3 5670 73
1250 AMA 500L8L

600 r/min = 10 poles


491 744 96.0 96.3 0.85 0.83

10000 V 50 Hz
88 5.3 29 16040 0.8 1.9 93.0 5680 73
2
500 AMA 500L10L 188 594 94.4 94.6 0.82 0.78 37 5.4 16 8034 0.8 2.2 66.1 4750 73
560 AMA 500L10L 189 594 94.6 94.8 0.83 0.79 41 5.2 17 9002 0.8 2.1 70.4 4900 73
630 AMA 500L10L 190 594 94.7 95.0 0.83 0.80 46 5.1 18 10131 0.8 2.0 74.7 5050 73
710 AMA 500L10L 191 595 94.9 95.2 0.83 0.79 52 5.1 21 11404 0.7 2.1 79.9 5200 73
800 AMA 500L10L 492 595 95.0 95.3 0.83 0.79 59 5.1 24 12850 0.7 2.1 84.2 5350 73

500 r/min = 12 poles 10000 V 50 Hz


355 AMA 500L12L 192 494 93.3 93.7 0.79 0.74 28 4.2 13 6865 0.6 1.9 61.7 4620 73
400 AMA 500L12L 193 494 93.6 93.9 0.78 0.74 31 4.3 14 7733 0.6 1.9 66.0 4760 73
450 AMA 500L12L 194 494 93.8 94.0 0.77 0.72 36 4.5 17 8693 0.7 2.0 70.4 4910 73
500 AMA 500L12L 195 495 94.0 94.1 0.77 0.72 40 4.7 20 9654 0.7 2.1 79.1 5180 73
560 AMA 500L12L 196 494 94.1 94.2 0.78 0.72 44 4.6 21 10815 0.7 2.0 83.4 5330 73
630 AMA 500L12L 495 494 94.2 94.4 0.78 0.72 50 4.6 24 12169 0.7 2.0 87.7 5470 73

Data presented in rating lists are typical values.


Guaranteed values on request. All engineered motors
are optimized for the specified application. Accurate
motor data will be given on request at quotation phase.
Legally binding performance and specification data is
given to the end user once each order is confirmed.

ABB/ BU Machines / HV Induction motors IEC catalogue / Engineered motors EN 05-2006 99


Engineered motors, HXR
Dimension drawings
Antifriction bearings, 1 < UN ≤ 6.6 kV, IM 1001, IC411

HXR Poles A B C D E F H AE HD L K LD LE

2 355L
355L
2
≥4
610
610
630
630
254
254
70
100
140
210
20
28
355
355
980
980
1195
1195
1505
1670
35
35
1080
1150
380
450
400L 2 710 900 224 80 170 22 400 1030 1285 1765 35 1325 430
400L ≥4 710 900 224 110 210 28 400 1030 1285 1900 35 1365 470
450L 2 800 1000 250 80 170 22 450 1075 1385 1985 42 1520 445
450L ≥4 800 1000 250 110 210 28 450 1075 1385 2120 42 1560 485
500L 2 900 1250 280 90 170 25 500 1175 1510 2320 42 1800 460
500L ≥4 900 1250 280 120 210 32 500 1175 1510 2455 42 1840 500
560L ≥4 1000 1600 400 160 300 40 560 1285 1655 3025 48 2350 630

HXR Poles AA AB AC BA BB HA D-end bearing N-end bearing

355L 2 120 700 745 210 886 55 6317M/C3 6317M/C3


355L ≥4 120 700 745 210 886 55 6322/C3 6319/C3
400L 2 140 840 840 260 1120 35 6317M/C3 6317M/C3
400L ≥4 140 840 840 260 1120 35 6324/C3 6319/C3
450L 2 160 950 940 320 1300 40 6317M/C3 6317M/C3
450L ≥4 160 950 940 320 1300 40 6324/C3 6322/C3
500L 2 170 1050 1050 375 1570 45 6319M/C3 6319M/C3
500L ≥4 170 1050 1050 375 1570 45 6326/C3 6324/C3
560L ≥4 230 1170 1190 620 1940 50 6034/C3 + NU1034/C3 NU322/C3

The above table gives the main dimensions in mm.


The customer is responsible for the preparation of the
foundation. Certified outline drawing is delivered with each
purchase order. The motor's rotational direction will be as
specified in the order.

100 ABB/ BU Machines / HV Induction motors IEC catalogue / Engineered motors EN 05-2006
Engineered motors, HXR
Dimension drawings
Antifriction bearings, 6.6 < UN ≤ 11 kV, IM1001, IC411

HXR Poles A B C D E F H AE HD L K LD LE

450L 2 800 1000 250 80 170 22 450 1225 1505 1985 42 1520 445 2
450L ≥4 800 1000 250 110 210 28 450 1225 1505 2120 42 1560 485
500L 2 900 1250 280 90 170 25 500 1280 1630 2320 42 1800 460
500L ≥4 900 1250 280 120 210 32 500 1280 1630 2455 42 1840 500
560L ≥4 1000 1600 400 160 300 40 560 1360 1780 3025 48 2350 630

HXR Poles AA AB AC BA BB HA D-end bearing N-end bearing

450L 2 160 950 940 320 1300 40 6317/C3 6317/C3


450L ≥4 160 950 940 320 1300 40 6324/C3 6322/C3
500L 2 170 1050 1050 375 1570 45 6319M/C3 6319M/C3
500L ≥4 170 1050 1050 375 1570 45 6326/C3 6324/C3
560L ≥4 230 1170 1190 620 1940 50 6034/C3 + NU1034/C3 NU322/C3

The above table gives the main dimensions in mm.


The customer is responsible for the preparation of the
foundation. Certified outline drawing is delivered with each
purchase order. The motor's rotational direction will be as
specified in the order.

ABB/ BU Machines / HV Induction motors IEC catalogue / Engineered motors EN 05-2006 101
Engineered motors, HXR
Dimension drawings
Antifriction bearings, 1 < UN ≤ 6.6 kV, IM3011, IC411

HXR Poles M N P S D E F G GD HD L LA

2 355L
355L
2
≥4
740
740
680
680
800
800
23
23
70
100
140
210
20
28
62.5
90
12
16
1225
1225
1505
1670
25
25
400L 2 940 880 1000 28 80 170 22 71 14 1370 1765 30
400L ≥4 940 880 1000 28 110 210 28 100 16 1370 1900 30
450L ≥4 1080 1000 1150 28 110 210 28 100 16 1495 2120 30
500L ≥4 1080 1000 1150 28 120 210 32 109 18 1570 2455 30
560L ≥6 1320 1250 1400 28 160 300 40 147 22 1780 3005 40

HXR Poles LD LE LF T AC AD AE D-end bearing N-end bearing

355L 2 395 1080 130 6 750 822 745 6317M/C3 7317 BM


355L 4 465 1150 130 6 750 822 745 6322/C3 7319 BM
400L 2 425 1315 150 6 840 867 790 6317M/C3 7317 BM
400L ≥4 465 1355 150 6 840 867 790 6324/C3 7319 BM
450L ≥4 480 1555 180 6 940 917 840 6324/C3 7322 BM
500L ≥4 510 1850 200 6 1040 992 915 6326/C3 7324 BM
560L ≥6 630 2350 250 6 1190 1077 1000 6034/C3 7334 BM
Note! Rain canopy is recommended for outdoor location.

The above table gives the main dimensions in mm.


The customer is responsible for the preparation of the
foundation. Certified outline drawing is delivered with each
purchase order. The motor's rotational direction will be as
specified in the order.

102 ABB/ BU Machines / HV Induction motors IEC catalogue / Engineered motors EN 05-2006
Engineered motors, HXR
Dimension drawings
Antifriction bearings, 6.6 < UN ≤ 11 kV, IM 3011, IC411

HXR Poles M N P S D E F G GD HD L LA

450L ≥4 1080 1000 1150 28 110 210 28 100 16 1590 2120 30 2


500L ≥4 1080 1000 1150 28 120 210 32 109 18 1665 2455 30
560L ≥6 1320 1250 1400 28 160 300 40 147 22 1875 3005 40

HXR Poles LD LE LF T AC AD AE D-end bearing N-end bearing

450L ≥4 480 1555 180 6 940 1012 935 6324/C3 7322 BM


500L ≥4 510 1850 200 6 1040 1087 1010 6326/C3 7324 BM
560L ≥6 630 2350 250 6 1190 1172 1095 6034/C3 7334 BM
Note! Rain canopy is recommended for outdoor location.

The above table gives the main dimensions in mm.


The customer is responsible for the preparation of the
foundation. Certified outline drawing is delivered with each
purchase order. The motor's rotational direction will be as
specified in the order.

ABB/ BU Machines / HV Induction motors IEC catalogue / Engineered motors EN 05-2006 103
Engineered motors, HXR
Dimension drawings
Sleeve bearings, 1 < UN ≤ 6.6 kV, IM 1001, IC411

HXR Poles A B C D E F H AE HD L K LD LE

2 355L
355L
2
≥4
610
610
630
630
475
475
70
100
140
210
20
28
355
355
980
980
1195
1195
1905
2075
35
35
1300
1370
600
670
400L 2 710 900 450 80 170 22 400 1030 1285 2170 35 1550 655
400L ≥4 710 900 450 110 210 28 400 1030 1285 2305 35 1590 695
450L 2 800 1000 475 80 170 22 450 1075 1385 2390 42 1745 670
450L ≥4 800 1000 475 110 210 28 450 1075 1385 2525 42 1785 710
500L 2 900 1250 500 90 170 25 500 1175 1510 2705 42 2020 680
500L ≥4 900 1250 500 120 210 32 500 1175 1510 2840 42 2060 720
560L 2 1000 1600 670 120 210 32 560 1285 1655 3280 48 2530 810
560L ≥4 1000 1600 670 160 300 40 560 1285 1655 3465 48 2620 900

HXR Poles AA AB AC BA BB HA D-end bearing N-end bearing

355L 2 120 700 750 210 886 55 EFZLB 9-80 1) EFZLQ 9-80 1)
355L ≥4 120 700 750 210 886 55 EFZLB 9-90 EFZLQ 9-90
400L 2 140 840 840 260 1120 35 EFZLB 9-80 1) EFZLQ 9-80 1)
400L ≥4 140 840 840 260 1120 35 EFZLB 9-100 EFZLQ 9-100
450L 2 160 950 940 320 1300 40 EFZLB 9-80 1) EFZLQ 9-80 1)
450L ≥4 160 950 940 320 1300 40 EFZLB 9-100 2) EFZLQ 9-100 2)
500L 2 170 1050 1050 375 1570 45 EFZLB 9-90 1) EFZLQ 9-90 1)
500L ≥4 170 1050 1050 375 1570 45 EFZLB 11-100 2) EFZLQ 9-100 2)
560L 2 230 1170 1190 620 1940 50 EFZLB 14-125 1) EFZLQ 14-125 1)
560L 4, 6 230 1170 1190 620 1940 50 EFZLB 14-125 2) EFZLQ 14-125 2)
560L ≥8 230 1170 1190 620 1940 50 EFZLB 14-140 EFZLQ 14-140
1)
With oil circulation as standard. The above table gives the main dimensions in mm.
2)
With oil circulation as standard for 4 poles.
The customer is responsible for the preparation of the
Note! Axial float of rotor as standard ±8 mm.
foundation. Certified outline drawing is delivered with each
Note! The bearing cannot withstand continuous axial forces.
purchase order. The motor's rotational direction will be as
specified in the order.

104 ABB/ BU Machines / HV Induction motors IEC catalogue / Engineered motors EN 05-2006
Engineered motors, HXR
Dimension drawings
Sleeve bearings, 6.6 < UN ≤ 11 kV, IM 1001, IC411

HXR Poles A B C D E F H AE HD L K LD LE

450L
450L
2
≥4
800
800
1000
1000
475
475
80
110
170
210
22
28
450
450
1225
1225
1505
1505
2390
2525
42
42
1745
1785
670
710
2
500L 2 900 1250 500 90 170 25 500 1280 1630 2705 42 2020 680
500L ≥4 900 1250 500 120 210 32 500 1280 1630 2840 42 2060 720
560L 2 1000 1600 670 120 210 32 560 1360 1780 3280 48 2530 810
560L ≥4 1000 1600 670 160 300 40 560 1360 1780 3465 48 2620 900

HXR Poles AA AB AC BA BB HA D-end bearing N-end bearing

450L 2 160 950 940 320 1300 40 EFZLB 9-80 1) EFZLQ 9-80 1)
450L ≥4 160 950 940 320 1300 40 EFZLB 9-100 2) EFZLQ 9-100 2)
500L 2 170 1050 1050 375 1570 45 EFZLB 9-90 1) EFZLQ 9-90 1)
500L ≥4 170 1050 1050 375 1570 45 EFZLB 11-100 2) EFZLQ 9-100 2)
560L 2 230 1170 1190 620 1940 50 EFZLB 14-125 1) EFZLQ 14-125 1)
560L 4, 6 230 1170 1190 620 1940 50 EFZLB 14-125 2) EFZLQ 14-125 2)
560L ≥4 230 1170 1190 620 1940 50 EFZLB 14-140 EFZLQ 14-140
1)
With oil circulation as standard.
2)
With oil circulation as standard for 4 poles.
Note! Axial float of rotor as standard ±8 mm.
Note! The bearing cannot withstand continuous axial forces.

The above table gives the main dimensions in mm.


The customer is responsible for the preparation of the
foundation. Certified outline drawing is delivered with each
purchase order. The motor's rotational direction will be as
specified in the order.

ABB/ BU Machines / HV Induction motors IEC catalogue / Engineered motors EN 05-2006 105
Engineered motors, AMA
Dimension drawings
Antifriction bearings, 1 < UN ≤ 6.6 kV, IM 1001, IC01 / IP24W

AMA Poles A B C D E F G H K L AA AB AC AD

2 400L
400L
2
≥4
750
750
1250
1250
200
200
85
110
170
210
22
28
76
100
400
400
35
35
1825
1865
150
150
880
880
855
855
335
335
450L 2 850 1400 200 90 170 25 81 450 42 1975 150 980 905 335
450L ≥4 850 1400 200 125 210 32 114 450 42 2025 150 980 905 335
500L ≥4 950 1600 200 140 250 36 128 500 42 2265 150 1080 955 335

AMA Poles AE BA BB BC GD HA HB HC LD LE HU D-end bearing N-end bearing

400L 2 1400 545 1450 445 14 20 130 1710 615 1480 565 6319M/C3 6319M/C3
400L ≥4 1400 545 1450 445 16 20 130 1710 655 1520 565 6324/C3 6319/C3
450L 2 1500 575 1600 465 14 25 230 1860 710 1630 665 6319M/C3 6319M/C3
450L ≥4 1500 575 1600 465 18 25 230 1860 750 1670 665 6326/C3 6322/C3
500L ≥4 1605 645 1800 495 20 35 330 2060 860 1910 765 6330/C3 6324/C3

The above table gives the main dimensions in mm.


The customer is responsible for the preparation of the
foundation. Certified outline drawing is delivered with each
purchase order. The motor's rotational direction will be as
specified in the order.

106 ABB/ BU Machines / HV Induction motors IEC catalogue / Engineered motors EN 05-2006
Engineered motors, AMA
Dimension drawings
Antifriction bearings, 1 < UN ≤ 6.6 kV, IM 4011, IC01 / IP24W

AMA Poles M N P S D E F G HD L LA LD LE

400L ≥4 1080 1000js6 1130 28 110 210 28 100 1875 1860 30 655 1150 2
450L ≥4 1180 1120h8 1230 28 125 210 32 114 2025 2020 40 750 1300
500L ≥4 1320 1250h8 1370 28 140 250 36 128 2245 2260 47 860 1540

AMA Poles T AC AD AE GD HU D-end bearing N-end bearing

400L ≥4 6 855 775 1425 16 50 6324/C3 7319B


450L ≥4 7 905 825 1525 18 50 6326/C3 7322B
500L ≥4 8 955 875 1645 20 50 6330/C3 7324B

The above table gives the main dimensions in mm.


The customer is responsible for the preparation of the
foundation. Certified outline drawing is delivered with each
purchase order. The motor's rotational direction will be as
specified in the order.

ABB/ BU Machines / HV Induction motors IEC catalogue / Engineered motors EN 05-2006 107
Engineered motors, AMA
Dimension drawings
Sleeve bearings, 1 < UN ≤ 6.6 kV, IM 1001, IC01 / IP24W

AMA Poles A B C D E F G H K L AA AB AC AD AE BA

2 400L 2 750 1250 375 85 170 22 76 400 35 2065 150 880 855 335 1400 545
400L ≥4 750 1250 375 110 210 28 100 400 35 2100 150 880 855 335 1400 545
450L 2 850 1400 375 90 170 25 81 450 42 2215 150 980 905 335 1500 575
450L ≥4 850 1400 400 125 210 32 114 450 42 2275 150 980 905 335 1500 575
500L 2 950 1600 375 110 210 28 100 500 42 2485 150 1080 955 335 1605 645
500L ≥4 950 1600 450 140 250 36 128 500 42 2595 150 1080 955 335 1605 645

AMA Poles BB BC GD HA HB HC LD LE HU D-end bearing N-end bearing

400L 2 1450 445 14 20 130 1710 790 1655 565 EFZLB9-80 EFZLQ9-80
400L ≥4 1450 445 16 20 130 1710 830 1695 565 EFZLB9-100 EFZLQ 9-100
450L 2 1600 465 14 25 230 1860 885 1805 665 EFZLB9-80 EFZLQ 9-80
450L ≥4 1600 465 18 25 230 1860 950 1870 665 EFZLB11-125 EFZLQ9-100
500L 2 1800 495 16 35 330 2060 995 2045 765 EFNLB11-90 EFNLB11-90
500L 4 1800 495 20 35 330 2060 1110 2160 765 EFZLB14-125 EFZLQ11-125
500L ≥6 1800 495 20 35 330 2060 1110 2160 765 EFZLB14-140 EFZLQ11-125
Note! Axial float of rotor as standard ±8 mm.
Note! The bearing cannot withstand continuous axial forces.

The above table gives the main dimensions in mm.


The customer is responsible for the preparation of the
foundation. Certified outline drawing is delivered with each
purchase order. The motor's rotational direction will be as
specified in the order.

108 ABB/ BU Machines / HV Induction motors IEC catalogue / Engineered motors EN 05-2006
Engineered motors, AMA
Dimension drawings
Antifriction bearings, 6.6 < UN ≤ 11 kV, IM 1001, IC01 / IP24W

AMA Poles A B C D E F G H K L AA AB AC AD

450L 2 850 1400 200 90 170 25 81 450 42 1975 150 980 1005 430 2
450L ≥4 850 1400 200 125 210 32 114 450 42 2025 150 980 1005 430
500L ≥4 950 1600 200 140 250 36 128 500 42 2265 150 1080 1055 430

AMA Poles AE BA BB BC GD HA HB HC LD LE HU D-end bearing N-end bearing

450L 2 1600 575 1600 465 14 25 35 1860 710 1630 665 6319M/C3 6319M/C3
450L ≥4 1600 575 1600 465 18 25 35 1860 750 1670 665 6326/C3 6322/C3
500L ≥4 1700 645 1800 495 20 35 135 2060 860 1910 765 6330/C3 6324/C3

The above table gives the main dimensions in mm.


The customer is responsible for the preparation of the
foundation. Certified outline drawing is delivered with each
purchase order. The motor's rotational direction will be as
specified in the order.

ABB/ BU Machines / HV Induction motors IEC catalogue / Engineered motors EN 05-2006 109
Engineered motors, AMA
Dimension drawings
Antifriction bearings, 6.6 < UN ≤ 11 kV, IM 4011, IC01 / IP24W

AMA Poles M N P S D E F G HD L LA LD LE

2 450L ≥4 1180 1120h8 1230 28 125 210 32 114 2025 2030 40 750 1100
500L ≥4 1320 1250h8 1370 28 140 250 36 128 2245 2270 47 860 1340

AMA Poles T AC AD AE GD HU D-end bearing N-end bearing

450L ≥4 7 1000 920 1620 18 50 6326/C3 7322B


500L ≥4 8 1050 970 1740 20 50 6330/C3 7324B

The above table gives the main dimensions in mm.


The customer is responsible for the preparation of the
foundation. Certified outline drawing is delivered with each
purchase order. The motor's rotational direction will be as
specified in the order.

110 ABB/ BU Machines / HV Induction motors IEC catalogue / Engineered motors EN 05-2006
Engineered motors, AMA
Dimension drawings
Sleeve bearings, 6.6 < UN ≤ 11 kV, IM 1001, IC01 / IP24W

AMA Poles A B C D E F G H K L AA AB AC AD AE BA

450L 2 850 1400 375 90 170 25 81 450 42 2215 150 980 1005 430 1600 575 2
450L ≥4 850 1400 400 125 210 32 114 450 42 2275 150 980 1005 430 1600 575
500L 2 950 1600 375 110 210 28 100 500 42 2485 150 1080 1055 430 1700 645
500L ≥4 950 1600 450 140 250 36 128 500 42 2595 150 1080 1055 430 1700 645

AMA Poles BB BC GD HA HB HC LD LE HU D-end bearing N-end bearing

450L 2 1600 465 14 25 35 1860 885 1805 665 EFZLB9-80 EFZLQ 9-80
450L ≥4 1600 465 18 25 35 1860 950 1870 665 EFZLB11-125 EFZLQ9-100
500L 2 1800 495 16 35 135 2060 995 2045 765 EFNLB11-90 EFNLB11-90
500L 4 1800 495 20 35 135 2060 1110 2160 765 EFZLB14-125 EFZLQ11-125
500L ≥6 1800 495 20 35 135 2060 1110 2160 765 EFZLB14-140 EFZLQ11-125
Note! Axial float of rotor as standard ±8 mm.
Note! The bearing cannot withstand continuous axial forces.

The above table gives the main dimensions in mm.


The customer is responsible for the preparation of the
foundation. Certified outline drawing is delivered with each
purchase order. The motor's rotational direction will be as
specified in the order.

ABB/ BU Machines / HV Induction motors IEC catalogue / Engineered motors EN 05-2006 111
Engineered motors, AMA
Dimension drawings
Antifriction bearings, 1 < UN ≤ 6.6 kV, IM 1001, IC81W / IP55

AMA Poles A B C D E F G H K L AA AB AC AD

2 400L
400L
2
≥4
750
750
1250
1250
200
200
85
110
170
210
22
28
76
100
400
400
35
35
1825
1865
150
150
880
880
855
855
335
335
450L 2 850 1400 200 90 170 25 81 450 42 1975 150 980 905 335
450L ≥4 850 1400 200 125 210 32 114 450 42 2025 150 980 905 335
500L ≥4 950 1600 200 140 250 36 128 500 42 2265 150 1080 955 335

AMA Poles AE BA BB BC GD HA HB HC LD LE HU D-end bearing N-end bearing

400L 2 1400 545 1450 445 14 20 130 1670 615 1480 565 6319M/C3 6319M/C3
400L ≥4 1400 545 1450 445 16 20 130 1670 655 1520 565 6324/C3 6319/C3
450L 2 1500 575 1600 465 14 25 230 1870 710 1630 665 6319M/C3 6319M/C3
450L ≥4 1500 575 1600 465 18 25 230 1870 750 1670 665 6326/C3 6322/C3
500L ≥4 1605 645 1800 495 20 35 330 2070 860 1910 765 6330/C3 6324/C3

The above table gives the main dimensions in mm.


The customer is responsible for the preparation of the
foundation. Certified outline drawing is delivered with each
purchase order. The motor's rotational direction will be as
specified in the order.

112 ABB/ BU Machines / HV Induction motors IEC catalogue / Engineered motors EN 05-2006
Engineered motors, AMA
Dimension drawings
Antifriction bearings, 1 < UN ≤ 6.6 kV, IM 4011, IC81W / IP55

AMA Poles M N P S D E F G HD L LA LD LE

400L ≥4 1080 1000js6 1130 28 110 210 28 100 1835 1860 30 655 1150 2
450L ≥4 1180 1120h8 1230 28 125 210 32 114 2035 2020 40 750 1300
500L ≥4 1320 1250h8 1370 28 140 250 36 128 2255 2260 47 860 1540

AMA Poles T AC AD AE GD HU D-end bearing N-end bearing

400L ≥4 6 855 775 1425 16 50 6324/C3 7319B


450L ≥4 7 905 825 1525 18 50 6326/C3 7322B
500L ≥4 8 955 875 1645 20 50 6330/C3 7324B

The above table gives the main dimensions in mm.


The customer is responsible for the preparation of the
foundation. Certified outline drawing is delivered with each
purchase order. The motor's rotational direction will be as
specified in the order.

ABB/ BU Machines / HV Induction motors IEC catalogue / Engineered motors EN 05-2006 113
Engineered motors, AMA
Dimension drawings
Sleeve bearings, 1 < UN ≤ 6.6 kV, IM 1001, IC81W / IP55

AMA Poles A B C D E F G H K L AA AB AC AD AE BA

2 400L
400L
2
≥4
750
750
1250
1250
375
375
85
110
170
210
22
28
76
100
400
400
35
35
2065
2100
150
150
880
880
855
855
335
335
1400
1400
545
545
450L 2 850 1400 375 90 170 25 81 450 42 2215 150 980 905 335 1500 575
450L ≥4 850 1400 400 125 210 32 114 450 42 2275 150 980 905 335 1500 575
500L 2 950 1600 375 110 210 28 100 500 42 2485 150 1080 955 335 1605 645
500L ≥4 950 1600 450 140 250 36 128 500 42 2595 150 1080 955 335 1605 645

AMA Poles BB BC GD HA HB HC LD LE HU D-end bearing N-end bearing

400L 2 1450 445 14 20 130 1670 790 1655 565 EFZLB9-80 EFZLQ9-80
400L ≥4 1450 445 16 20 130 1670 830 1695 565 EFZLB9-100 EFZLQ 9-100
450L 2 1600 465 14 25 230 1870 885 1805 665 EFZLB9-80 EFZLQ 9-80
450L ≥4 1600 465 18 25 230 1870 950 1870 665 EFZLB11-125 EFZLQ9-100
500L 2 1800 495 16 35 330 2070 995 2045 765 EFNLB11-90 EFNLB11-90
500L 4 1800 495 20 35 330 2070 1110 2160 765 EFZLB14-125 EFZLQ11-125
500L ≥6 1800 495 20 35 330 2070 1110 2160 765 EFZLB14-140 EFZLQ11-125
Note! Axial float of rotor as standard ±8 mm.
Note! The bearing cannot withstand continuous axial forces.

The above table gives the main dimensions in mm.


The customer is responsible for the preparation of the
foundation. Certified outline drawing is delivered with each
purchase order. The motor's rotational direction will be as
specified in the order.

114 ABB/ BU Machines / HV Induction motors IEC catalogue / Engineered motors EN 05-2006
Engineered motors, AMA
Dimension drawings
Antifriction bearings, 6.6 < UN ≤ 11 kV, IM 1001, IC81W / IP55
J

AMA Poles A B C D E F G H K L AA AB AC AD

450L 2 850 1400 200 90 170 25 81 450 42 1975 150 980 1005 430 2
450L ≥4 850 1400 200 125 210 32 114 450 42 2025 150 980 1005 430
500L ≥4 950 1600 200 140 250 36 128 500 42 2265 150 1080 1055 430

AMA Poles AE BA BB BC GD HA HB HC LD LE HU D-end bearing N-end bearing

450L 2 1600 575 1600 465 14 25 35 1870 710 1630 665 6319M/C3 6319M/C3
450L ≥4 1600 575 1600 465 18 25 35 1870 750 1670 665 6326/C3 6322/C3
500L ≥4 1700 645 1800 495 20 35 135 2070 860 1910 765 6330/C3 6324/C3

The above table gives the main dimensions in mm.


The customer is responsible for the preparation of the
foundation. Certified outline drawing is delivered with each
purchase order. The motor's rotational direction will be as
specified in the order.

ABB/ BU Machines / HV Induction motors IEC catalogue / Engineered motors EN 05-2006 115
Engineered motors, AMA
Dimension drawings
Antifriction bearings, 6.6 < UN ≤ 11 kV, IM 4011, IC81W / IP55

AMA Poles M N P S D E F G HD L LA LD LE

2 450L
500L
≥4
≥4
1180
1320
1120h8
1250h8
1230
1370
28
28
125
140
210
250
32
36
114
128
2035
2255
2030
2270
40
47
750
860
1100
1340

AMA Poles T AC AD AE GD HU D-end bearing N-end bearing

450L ≥4 7 1000 920 1620 18 50 6326/C3 7322B


500L ≥4 8 1050 970 1740 20 50 6330/C3 7324B

The above table gives the main dimensions in mm.


The customer is responsible for the preparation of the
foundation. Certified outline drawing is delivered with each
purchase order. The motor's rotational direction will be as
specified in the order.

116 ABB/ BU Machines / HV Induction motors IEC catalogue / Engineered motors EN 05-2006
Engineered motors, AMA
Dimension drawings
Sleeve bearings, 6.6 < UN ≤ 11 kV, IM 1001, IC81W / IP55

AMA Poles A B C D E F G H K L AA AB AC AD AE BA

450L
450L
2
≥4
850
850
1400
1400
375
400
90
125
170
210
25
32
81
114
450
450
42
42
2215
2275
150
150
980
980
1005
1005
430
430
1600
1600
575
575
2
500L 2 950 1600 375 110 210 28 100 500 42 2485 150 1080 1055 430 1700 645
500L ≥4 950 1600 450 140 250 36 128 500 42 2595 150 1080 1055 430 1700 645

AMA Poles BB BC GD HA HB HC LD LE HU D-end bearing N-end bearing

450L 2 1600 465 14 25 35 1870 885 1805 665 EFZLB9-80 EFZLQ 9-80
450L ≥4 1600 465 18 25 35 1870 950 1870 665 EFZLB11-125 EFZLQ9-100
500L 2 1800 495 16 35 135 2070 995 2045 765 EFNLB11-90 EFNLB11-90
500L 4 1800 495 20 35 135 2070 1110 2160 765 EFZLB14-125 EFZLQ11-125
500L ≥6 1800 495 20 35 135 2070 1110 2160 765 EFZLB14-140 EFZLQ11-125

The above table gives the main dimensions in mm.


The customer is responsible for the preparation of the
foundation. Certified outline drawing is delivered with each
purchase order. The motor's rotational direction will be as
specified in the order.

ABB/ BU Machines / HV Induction motors IEC catalogue / Engineered motors EN 05-2006 117
Engineered motors, AMA
Dimension drawings
Antifriction bearings, 1 < UN ≤ 6.6 kV, IM 1001, IC611 / IP55

AMA Poles A B C D E F G H K L AA AB AC AD

2 400L 2 750 1250 200 85 170 22 76 400 35 2290 150 880 855 335
400L ≥4 750 1250 200 110 210 28 100 400 35 2330 150 880 855 335
450L 2 850 1400 200 90 170 25 81 450 42 2480 150 980 905 335
450L ≥4 850 1400 200 125 210 32 114 450 42 2520 150 980 905 335
500L ≥4 950 1600 200 140 250 36 128 500 42 2830 150 1080 955 335

AMA Poles AE BA BB BC GD HA HB HC LD LE HU D-end bearing N-end bearing

400L 2 1400 545 1450 445 14 20 130 1590 615 1480 565 6319M/C3 6319M/C3
400L ≥4 1400 545 1450 445 16 20 130 1590 655 1520 565 6324/C3 6319/C3
450L 2 1500 575 1600 465 14 25 230 1760 710 1630 665 6319M/C3 6319M/C3
450L ≥4 1500 575 1600 465 18 25 230 1760 750 1670 665 6326/C3 6322/C3
500L ≥4 1605 645 1800 495 20 35 330 1960 860 1910 765 6330/C3 6324/C3

The above table gives the main dimensions in mm.


The customer is responsible for the preparation of the
foundation. Certified outline drawing is delivered with each
purchase order. The motor's rotational direction will be as
specified in the order.

118 ABB/ BU Machines / HV Induction motors IEC catalogue / Engineered motors EN 05-2006
Engineered motors, AMA
Dimension drawings
Antifriction bearings, 1 < UN ≤ 6.6 kV, IM 4011, IC611 / IP55

AMA Poles M N P S D E F G HD L LA LD LE

400L ≥4 1080 1000js6 1130 28 110 210 28 100 1755 2330 30 655 1150 2
450L ≥4 1180 1120h8 1230 28 125 210 32 114 1925 2520 40 750 1300
500L ≥4 1320 1250h8 1370 28 140 250 36 128 2145 2830 47 860 1540

AMA Poles T AC AD AE GD HU D-end bearing N-end bearing

400L ≥4 6 855 775 1425 16 50 6324/C3 7319B


450L ≥4 7 905 825 1525 18 50 6326/C3 7322B
500L ≥4 8 955 875 1645 20 50 6330/C3 7324B

The above table gives the main dimensions in mm.


The customer is responsible for the preparation of the
foundation. Certified outline drawing is delivered with each
purchase order. The motor's rotational direction will be as
specified in the order.

ABB/ BU Machines / HV Induction motors IEC catalogue / Engineered motors EN 05-2006 119
Engineered motors, AMA
Dimension drawings
Sleeve bearings, 1 < UN ≤ 6.6 kV, IM 1001, IC611 / IP55

AMA Poles A B C D E F G H K L AA AB AC AD AE BA

2 400L
400L
2
≥4
750
750
1250
1250
375
375
85
110
170
210
22
28
76
100
400
400
35
35
2465
2505
150
150
880
880
855
855
335
335
1400
1400
545
545
450L 2 850 1400 375 90 170 25 81 450 42 2655 150 980 905 335 1500 575
450L ≥4 850 1400 400 125 210 32 114 450 42 2720 150 980 905 335 1500 575
500L 2 950 1600 375 110 210 28 100 500 42 2965 150 1080 955 335 1605 645
500L ≥4 950 1600 450 140 250 36 128 500 42 3080 150 1080 955 335 1605 645

AMA Poles BB BC GD HA HB HC LD LE HU D-end bearing N-end bearing

400L 2 1450 445 14 20 130 1590 790 1655 565 EFZLB9-80 EFZLQ9-80
400L ≥4 1450 445 16 20 130 1590 830 1695 565 EFZLB9-100 EFZLQ 9-100
450L 2 1600 465 14 25 230 1760 885 1805 665 EFZLB9-80 EFZLQ 9-80
450L ≥4 1600 465 18 25 230 1760 950 1870 665 EFZLB11-125 EFZLQ9-100
500L 2 1800 495 16 35 330 1960 995 2045 765 EFZLB9-100 1) EFZLQ9-100 1)
500L 4 1800 495 20 35 330 1960 1110 2160 765 EFZLB14-125 EFZLQ11-125
500L ≥6 1800 495 20 35 330 1960 1110 2160 765 EFZLB14-140 EFZLQ11-125
1)
With oil circulation as standard.
Note! Axial float of rotor as standard ±8 mm.
Note! The bearing cannot withstand continuous axial forces.

The above table gives the main dimensions in mm.


The customer is responsible for the preparation of the
foundation. Certified outline drawing is delivered with each
purchase order. The motor's rotational direction will be as
specified in the order.

120 ABB/ BU Machines / HV Induction motors IEC catalogue / Engineered motors EN 05-2006
Engineered motors, AMA
Dimension drawings
Antifriction bearings, 6.6 < UN ≤ 11 kV, IM 1001, IC611 / IP55

AMA Poles A B C D E F G H K L AA AB AC AD

450L
450L
2
≥4
850
850
1400
1400
200
200
90
125
170
210
25
32
81
114
450
450
42
42
2480
2520
150
150
980
980
1005
1005
430
430
2
500L ≥4 950 1600 200 140 250 36 128 500 42 2830 150 1080 1055 430

AMA Poles AE BA BB BC GD HA HB HC LD LE HU D-end bearing N-end bearing

450L 2 1600 575 1600 465 14 25 35 1760 710 1630 665 6319M/C3 6319M/C3
450L ≥4 1600 575 1600 465 18 25 35 1760 750 1670 665 6326/C3 6322/C3
500L ≥4 1700 645 1800 495 20 35 135 1960 860 1910 765 6330/C3 6324/C3

The above table gives the main dimensions in mm.


The customer is responsible for the preparation of the
foundation. Certified outline drawing is delivered with each
purchase order. The motor's rotational direction will be as
specified in the order.

ABB/ BU Machines / HV Induction motors IEC catalogue / Engineered motors EN 05-2006 121
Engineered motors, AMA
Dimension drawings
Antifriction bearings, 6.6 < UN ≤ 11 kV, IM 4011, IC611 / IP55

AMA Poles M N P S D E F G HD L LA LD LE

2 450L
500L
≥4
≥4
1180
1320
1120h8
1250h8
1230
1370
28
28
125
140
210
250
32
36
114
128
1925
2145
2520
2830
40
47
750
860
1100
1340

AMA Poles T AC AD AE GD HU D-end bearing N-end bearing

450L ≥4 7 1000 920 1620 18 50 6326/C3 7322B


500L ≥4 8 1050 970 1740 20 50 6330/C3 7324B

The above table gives the main dimensions in mm.


The customer is responsible for the preparation of the
foundation. Certified outline drawing is delivered with each
purchase order. The motor's rotational direction will be as
specified in the order.

122 ABB/ BU Machines / HV Induction motors IEC catalogue / Engineered motors EN 05-2006
Engineered motors, AMA
Dimension drawings
Sleeve bearings, 6.6 < UN ≤ 11 kV, IM 1001, IC611 / IP55

AMA Poles A B C D E F G H K L AA AB AC AD AE BA

450L 2 850 1400 375 90 170 25 81 450 42 2655 150 980 1005 430 1600 575 2
450L ≥4 850 1400 400 125 210 32 114 450 42 2720 150 980 1005 430 1600 575
500L 2 950 1600 375 110 210 28 100 500 42 2965 150 1080 1055 430 1700 645
500L ≥4 950 1600 450 140 250 36 128 500 42 3080 150 1080 1055 430 1700 645

AMA Poles BB BC GD HA HB HC LD LE HU D-end bearing N-end bearing

450L 2 1600 465 14 25 35 1760 885 1805 665 EFZLB9-80 EFZLQ 9-80
450L ≥4 1600 465 18 25 35 1760 950 1870 665 EFZLB11-125 EFZLQ9-100
500L 2 1800 495 16 35 135 1960 995 2045 765 EFZLB9-100 1) EFZLQ9-100 1)
500L 4 1800 495 20 35 135 1960 1110 2160 765 EFZLB14-125 EFZLQ11-125
500L ≥6 1800 495 20 35 135 1960 1110 2160 765 EFZLB14-140 EFZLQ11-125
1)
With oil circulation as standard.
Note! Axial float of rotor as standard ±8 mm.
Note! The bearing cannot withstand continuous axial forces.

The above table gives the main dimensions in mm.


The customer is responsible for the preparation of the
foundation. Certified outline drawing is delivered with each
purchase order. The motor's rotational direction will be as
specified in the order.

ABB/ BU Machines / HV Induction motors IEC catalogue / Engineered motors EN 05-2006 123
2

124 ABB/ BU Machines / HV Induction motors IEC catalogue / Engineered motors EN 05-2006
Engineered Motors for Low Voltage
Variable Speed Drives
Squirrel cage three phase low voltage motors,
Up to 2240 kW

General information .........................126


Notes ...............................................129
Technical data..................................130
Dimension drawings ........................135

ABB/ BU Machines / HV Induction motors IEC catalogue / Motors for variable speed drives EN 05-2006 125
This section describes ABB's engineered motors Section 2. This section includes drawings showing the
for low voltage variable speed drives. The basic low voltage main terminal box.
mechanical construction is the same as described in

General Information
The voltage (or current) fed by the frequency converter Insulation system, similar to that used in the high
is not purely sinusoidal. This may increase any losses, voltage motors. This construction yields very moderate
vibration and the noise of the motor. The engineered voltage stresses between the winding elements
motors described in this section are specifically even when supplied with the most efficient inverter
designed for supply through a frequency converter. types and the steepest voltage pulses. This makes
The design can be varied according to the customer's installation easier and results in lower losses and better
specifications including altering the speed range for performance for the entire drive system as no chokes or
continuous operation and operating with short-time filters are needed.
overload. ABB design considers the different types of
variable speed drive available depending upon their Bearing voltages and currents must be avoided in all
electromagnetic design. The rating for motors designed motors and all ABB large motors for low voltage variable
for converter supply differs from that of the direct-on- speed drives are equipped with bearing insulation in
line (DOL) motors. non-drive end. Please contact ABB for more information
about bearing currents and voltages.
In addition to the standard information given on the
rating plates there is additional information that relates AC machines supplied from a frequency converter must
to frequency converter driven machines. An example of be fitted with screened cables to comply with the EMC
the rating plate is shown on page 128. directive (89/336/EEC, as amended by 93/68/EEC).
Please see ABB's 'Manual for Induction Motors and
All the motors described in this catalog come with Generators' (code: 3BFP 000 050 R0101) or contact us
the form wound winding Micadur® Compact Industry for more information about EMC compliance.

Examples of different load types


Variable Torque (pumps, fans, etc.)
The table below shows the electrical rating plate is assumed to be quadratic (as function of speed), and
values for rated power, voltage, current, power factor, the motor can be operated continuously over the entire
frequency and speed of a pump drive. The load torque speed range. The field weakening point is 42.7 Hz.

3 CONVERTER SUPPLY
S1
0 - 1200 kW
0.5

0 - 660 V 0
0 - 42.7 Hz
0 1
0 - 1360 A
0 - 850 rpm speed
0 - 0.79 PF

Table above: Rating plate values for a pump drive. Figure above: Load torque curve for a pump drive.

126 ABB/ BU Machines / HV Induction motors IEC catalogue / Motors for variable speed drives EN 05-2006
Constant Torque Load
Certain applications can be regarded as constant The table below shows the rated values for a constant
torque loads. These include paper machines, and torque drive. Because it is a self-cooled machine,
extruders and other gear pumps. One of the advantages the rated torque cannot be utilized at zero speed
of AC drives is that, because there is no commutator, continuously. The continuous operational speed is from
the AC motor can produce torque at zero speed without 340 rpm to 1750 rpm. In this example, the motor is also
harmful effects, which is needed by some applications. capable of delivering an overload of up to 130% of the
The amount of continuous torque available at low rated torque.
speeds is dependent on the cooling method and often a
separately driven cooling fan will be the optimal choice.

CONVERTER SUPPLY
S1
183 - 750 - 940 kW
162 - 660 - 660 V 1.5
17.2 - 70.0 - 87.8 Hz
828 - 828 - 992 A
340 - 1396 - 1750 rpm 1
0.82 - 0.82 - 0.85 PF

OVERLOAD 130% 60 s / 10 min 0.5


1043 - 1043 - 1314 A
0 - 1395 - 1750 rpm 0
INVERTER PARAMETER SETTING: 0 1
940 kW / 660 V / 70.0 Hz /1009 A / 1395 rpm / speed
0.84 PF / TRN = 1785 ms / Tmax/Tn = 2.2

Table above: Rating plate values for a constant torque Figure above: Load torque curve for a constant torque
drive. drive.

Constant Torque and Constant Power


For some specialist applications such as paper load. To overcome these challenges a relatively high
unwinders, reelers and metal industry coilers, the overload is often required at base speed. The field
operational speed range is divided into two sections. weakening frequency is often slightly higher than the
When operating between zero speed and base speed base speed, giving an ideal combination for the inverter
the load has a constant torque and from base speed to and motor.
maximum speed it operates as a constant power. The
application requires constant tension (pull) in the web, The table below shows the rating plate values for a
that requires constant power on the motor shaft if the winder/unwind drive. In this case the normal operation
roll is centre driven. When the web speed is kept speed range is from 540 rpm to 2130 rpm. The field
constant the motor speed increases or decreases weakening point is at 36 Hz, since that is the frequency,
as the roll diameter increases or decreases. Over a
specific speed range this results in a constant power
when the nominal voltage (380 V) is reached. The drive
requirement is to deliver a varying overload from
707 kW at 540 rpm to 386 kW at 2130 rpm.
3
CONVERTER SUPPLY 3
S1
0 - 284 - 284 - 284 kW
0 - 287 - 380 - 380 V
0 - 27.2 - 36.0 - 107.0 Hz 2
torque

770 - 770 - 645 - 520 A


0 - 540 - 717 - 2130 rpm
- 0.77 - 0.69 - 0.87 PF
1
OVERLOAD 60 s / 10 min
1043 - 1043 - 1314 A
0 - 1395 - 1750 rpm
0
INVERTER PARAMETER SETTING: 0 1 2 3
407 kW / 380 V / 36.0 Hz / 811 A / 715 rpm /
speed
0.79 PF / TRN = 1160 ms / Tmax/Tn = 3.2

Table above: Rating plate values for a constant torque Figure above: Load torque curve for a constant torque
drive. drive.

ABB/ BU Machines / HV Induction motors IEC catalogue / Motors for variable speed drives EN 05-2006 127
Frequency Converter & By-pass Drive
In some applications, the frequency converter is fed motor to start the load. During frequency converter
directly from the mains, the direct-on-line (DOL) method. operation, the motor is normally capable of starting with
In these applications, the motor should be checked to a higher mass of inertia and higher starting torque. In
ensure it is: some cases the load torque can be decreased by, for
- suitable for direct-on-line operation (rated frequency example, closing the valves of the pump (or fan).
and voltage vs. the network)
- capable of starting the load (starting torque curve vs. The starting current is normally much higher than the
load curve, inertia). rated current (often 600%), thus during by-pass starting
the voltage drop in the network might exceed given
To be suitable for DOL operation the field weakening limits. In all cases the transients in DOL-starts must be
point choice and that the operational speed is defined considered, such as, forces to the foundation and the
by the net frequency. The load torque must be checked shaft torques.
as the power requirement will change if the operating
speed changes and the motor capacity must be The table below shows the rating plate values for
checked. For example, the pump loads can be much converter supply and DOL operation. In this example,
higher if the operating speed is increased because of the rated frequency is the same for both applications.
the higher frequency. If the motor is designed for by-pass operation it is
equipped with two rating plates: one for converter
In many cases the starting torque available with the supply and one for by-pass (DOL).
frequency converter which may affect the ability of the

CONVERTER SUPPLY BY-PASS


S1 800 kW
0 - 680 kW 660 V
0 - 660 V 50 Hz
0 - 50 Hz 849 A
0 - 728 A 994 rpm
0 - 995 rpm 0.85 PF
0 - 0.84 PF

Table above: Rating plate values for a by-pass drive.

Rating plate

128 ABB/ BU Machines / HV Induction motors IEC catalogue / Motors for variable speed drives EN 05-2006
Notes
All ratings in this catalogue are designed for the
following:
- Class F insulation / Maximum temperature rise of
80 °C by resistance with ABB ACS600 & ACS800
frequency converter
- Maximum 40 °C ambient
- Altitude of 1000 meters or less
- Data presented in rating lists are typical values.
Guaranteed values are available on request. All
engineered motors are optimized for the specified
application. Accurate motor data will be given on
request at quotation phase. Legally binding
performance and specification data is given to the end
user once each order is confirmed.
- Rating list data based on rated voltage at motor
terminals.
- All motors are designed for quadratric load torque
application (centrifucal pumps, fans), field wiekening
point and maximum speed at 50 Hz.
- Please contact ABB for all other applications,
converter types or speed range.

ABB/ BU Machines / HV Induction motors IEC catalogue / Motors for variable speed drives EN 05-2006 129
LV Cast iron motors, HXR 690 V - 50 Hz
Technical data for totally enclosed squirrel
cage three phase motors
IP 55 - IC 411 - Insulation class F, temperature rise class B
Efficiency Power factor Current Torque Sound
Full Full IN I0 TN Tmax Rotor Motor pressure
Output Motor Product Speed load load inertia weight level LP
kW type ID r/min 100% 100% A A Nm TN kgm2 kg dB(A)

1500 r/min = 4 poles 690 V 50 Hz


355 HXR 400LB4 VSD10001 1492 96.4 0.84 367 147 2273 2.5 10.3 2540 79
400 HXR 400LC4 VSD10002 1491 96.6 0.86 406 145 2561 2.4 11.4 2660 79
450 HXR 400LD4 VSD10003 1491 96.7 0.86 451 152 2882 2.3 12.5 2800 79
500 HXR 400LF4 VSD10004 1491 96.9 0.88 493 146 3203 2.2 14.7 3060 79
560 HXR 400LH4 VSD10005 1493 97.1 0.87 558 198 3582 2.6 16.9 3330 79
630 HXR 450LG4 VSD10006 1493 97.1 0.89 612 182 4030 2.4 26.8 4220 80
710 HXR 450LH4 VSD10007 1494 97.3 0.88 695 234 4539 2.8 28.6 4390 80
800 HXR 500LG4 VSD10008 1494 97.3 0.88 784 254 5114 2.6 44.1 5840 82
900 HXR 500LH4 VSD10009 1493 97.3 0.89 871 232 5758 2.2 46.9 6040 82
1000 HXR 500LJ4 VSD10010 1495 97.5 0.87 984 349 6389 2.9 49.8 6220 82
1120 HXR 500LN4 VSD10011 1493 97.5 0.90 1071 262 7165 2.1 61.1 7010 82
1250 HXR 560LJ4 VSD10012 1493 97.6 0.89 1203 306 7993 2.1 83.3 9290 84
1400 HXR 560LM4 VSD10013 1495 97.8 0.88 1360 456 8941 2.9 98.0 10060 84
1600 HXR 560LT4 VSD10014 1496 97.9 0.89 1538 474 10215 2.7 142.3 12170 84

1000 r/min = 6 poles 690 V 50 Hz


315 HXR 400LC6 VSD10015 994 96.2 0.78 351 176 3026 2.5 16.9 2610 80
355 HXR 400LD6 VSD10016 994 96.3 0.79 392 192 3409 2.5 18.6 2740 80
400 HXR 400LF6 VSD10017 994 96.5 0.81 428 189 3842 2.4 21.9 3000 80
450 HXR 400LH6 VSD10018 995 96.7 0.82 477 207 4321 2.4 25.3 3260 80
500 HXR 450LF6 VSD10019 995 97.0 0.83 517 213 4798 2.6 35.4 4030 82
560 HXR 450LG6 VSD10020 995 97.1 0.83 579 238 5373 2.6 38.1 4200 82
630 HXR 450LJ6 VSD10021 995 97.2 0.85 640 245 6045 2.5 43.5 4530 82
710 HXR 450LL6 VSD10022 995 97.3 0.85 718 270 6812 2.5 48.9 4860 82
800 HXR 500LG6 VSD10023 994 97.2 0.84 815 290 7682 2.1 57.8 5750 84
900 HXR 500LK6 VSD10024 996 97.4 0.83 934 390 8632 2.6 69.4 6320 84
1000 HXR 500LN6 VSD10025 996 97.5 0.83 1036 439 9588 2.7 81.1 6920 84
1120 HXR 560LK6 VSD10026 995 97.5 0.86 1120 341 10744 1.9 120.1 9370 85
1250 HXR 560LL6 VSD10027 996 97.6 0.85 1265 453 11983 2.2 127.0 9630 85
3 1400
1600
HXR 560LQ6
HXR 560LU6
VSD10028
VSD10029
997
997
97.7
97.8
0.85
0.85
1411
1601
514
582
13416
15328
2.4
2.5
154.5
202.6
10640
12370
85
85

Data presented in rating lists are typical values.


Guaranteed values on request. All engineered motors
are optimized for the specified application. Accurate
motor data will be given on request at quotation phase.
Legally binding performance and specification data is
given to the end user once each order is confirmed.

130 ABB/ BU Machines / HV Induction motors IEC catalogue / Motors for variable speed drives EN 05-2006
LV Cast iron motors, HXR 690 V - 50 Hz
Technical data for totally enclosed squirrel
cage three phase motors
IP 55 - IC 411 - Insulation class F, temperature rise class B
Efficiency Power factor Current Torque Sound
Full Full IN I0 TN Tmax Rotor Motor pressure
Output Motor Product Speed load load inertia weight level LP
kW type ID r/min 100% 100% A A Nm TN kgm2 kg dB(A)

750 r/min = 8 poles 690 V 50 Hz


224 HXR 400LC8 VSD10030 742 95.4 0.75 261 130 2882 2.0 16.5 2610 82
250 HXR 400LE8 VSD10031 743 95.7 0.76 288 143 3214 2.1 19.8 2870 82
280 HXR 400LF8 VSD10032 743 95.8 0.76 321 159 3599 2.1 21.5 3000 82
315 HXR 400LH8 VSD10033 743 95.9 0.78 354 163 4051 2.0 24.7 3250 82
355 HXR 450LD8 VSD10034 746 96.3 0.75 412 215 4546 2.2 30.4 3670 83
400 HXR 450LE8 VSD10035 746 96.4 0.75 462 240 5122 2.2 33.1 3840 83
450 HXR 450LF8 VSD10036 745 96.4 0.78 504 237 5765 2.0 35.8 3980 83
500 HXR 450LH8 VSD10037 746 96.6 0.79 552 250 6404 2.0 41.2 4310 83
560 HXR 450LL8 VSD10038 746 96.7 0.80 606 258 7172 2.0 49.4 4800 83
630 HXR 500LJ8 VSD10039 746 96.5 0.80 680 285 8067 2.0 66.6 6110 84
710 HXR 500LK8 VSD10040 746 96.7 0.81 764 315 9092 2.0 70.5 6310 84
800 HXR 500LL8 VSD10041 746 96.8 0.80 861 357 10244 2.0 74.5 6510 84
900 HXR 500LM8 VSD10042 746 96.8 0.80 975 415 11523 2.0 78.4 6710 84
1000 HXR 500LQ8 VSD10043 746 96.9 0.81 1065 423 12806 1.9 90.3 7310 84
1120 HXR 560LN8 VSD10044 747 97.4 0.80 1209 518 14327 2.0 143.2 10110 85
1250 HXR 560LQ8 VSD10045 747 97.4 0.79 1354 596 15987 2.1 157.2 10550 85
1400 HXR 560LT8 VSD10046 746 97.5 0.82 1475 567 17911 1.9 199.2 12090 85

Data presented in rating lists are typical values.


Guaranteed values on request. All engineered motors
are optimized for the specified application. Accurate
motor data will be given on request at quotation phase.
Legally binding performance and specification data is
given to the end user once each order is confirmed.

ABB/ BU Machines / HV Induction motors IEC catalogue / Motors for variable speed drives motors EN 05-2006 131
LV Modular motors 690 V - 50 Hz
Technical data for totally enclosed squirrel
cage three phase motors
IP 55 - IC 611 - Insulation class F, temperature rise class B
Efficiency Power factor Current Torque Sound
Full Full IN I0 TN Tmax Rotor Motor pressure
Output Motor Product Speed load load inertia weight level LP
kW type ID r/min 100% 100% A A Nm TN kgm2 kg dB(A)

1500 r/min = 4 poles 690 V 50 Hz


630 AMA 400L4A VSD10085 1487 95.5 0.85 649 237 4045 2.4 16.3 3150 82
710 AMA 400L4A VSD10086 1485 95.5 0.88 703 183 4566 2.0 17.3 3240 82
800 AMA 400L4A VSD10087 1485 95.7 0.88 792 213 5144 2.0 18.3 3350 82
900 AMA 400L4A VSD10088 1486 96.0 0.88 897 266 5783 2.2 19.3 3460 82
1000 AMA 400L4A VSD10089 1484 95.9 0.89 980 220 6437 1.8 20.3 3560 82
1120 AMA 450L4A VSD10090 1487 95.7 0.86 1136 330 7192 1.9 29.5 4130 83
1250 AMA 450L4A VSD10091 1488 96.0 0.87 1247 344 8022 2.0 32.9 4390 83
1400 AMA 450L4A VSD10092 1489 96.3 0.87 1396 415 8978 2.2 36.4 4630 83
1600 AMA 500L4A VSD10093 1490 96.0 0.89 1559 396 10251 2.2 55 5620 84
1800 AMA 500L4A VSD10094 1489 96.0 0.90 1739 337 11547 1.9 57.9 5780 84
2000 AMA 500L4A VSD10095 1491 96.5 0.91 1915 449 12810 2.3 66.7 6270 84
2240 AMA 500L4A VSD10096 1490 96.5 0.91 2145 449 14359 2.1 66.7 6270 84

1000 r/min = 6 poles 690 V 50 Hz


450 AMA 400L6A VSD10097 987 95.0 0.84 474 163 4355 1.7 16.8 2970 82
500 AMA 400L6A VSD10098 987 95.2 0.84 525 182 4836 1.8 18 3070 82
560 AMA 400L6A VSD10099 987 95.4 0.85 577 178 5417 1.7 20.4 3270 82
630 AMA 400L6A VSD10100 988 95.5 0.84 656 229 6086 1.9 21.6 3340 82
710 AMA 400L6A VSD10101 989 95.8 0.84 741 275 6852 2.0 24 3540 82
800 AMA 450L6A VSD10102 989 95.7 0.87 804 241 7725 2.0 34.6 4020 82
900 AMA 450L6A VSD10103 989 95.9 0.87 903 270 8690 2.0 36.8 4140 82
1000 AMA 450L6A VSD10104 990 96.0 0.87 1008 321 9650 2.1 39 4270 82
1120 AMA 450L6A VSD10105 990 96.2 0.87 1117 340 10806 2.1 43.3 4520 82
1250 AMA 500L6A VSD10106 991 96.4 0.88 1231 334 12050 2.0 66.8 5600 82
1400 AMA 500L6A VSD10107 992 96.5 0.87 1391 438 13483 2.3 70.4 5750 82
1600 AMA 500L6A VSD10108 990 96.4 0.89 1570 382 15439 1.8 73.9 5900 82
1800 AMA 500L6A VSD10109 991 96.6 0.88 1766 479 17350 2.0 80.9 6180 82

750 r/min = 8 poles 690 V 50 Hz

3 280
315
355
AMA 400L8A
AMA 400L8A
AMA 400L8A
VSD10110
VSD10111
VSD10112
739
738
740
94.5
94.6
94.9
0.80
0.81
0.80
310
345
389
129
135
162
3618
4073
4583
1.9
1.8
2.0
18.5
19.8
22.6
2940
3040
3230
81
81
81
400 AMA 400L8A VSD10113 740 95.1 0.80 439 188 5161 2.0 23.9 3330 81
450 AMA 400L8A VSD10114 739 95.0 0.81 489 194 5813 1.9 25.3 3400 81
500 AMA 400L8A VSD10115 740 95.2 0.81 542 217 6455 1.9 28 3600 81
560 AMA 450L8A VSD10116 741 95.6 0.83 590 219 7212 1.9 39.3 3980 81
630 AMA 450L8A VSD10117 742 95.8 0.82 668 262 8109 2.0 41.9 4110 81
710 AMA 450L8A VSD10118 741 95.8 0.83 745 272 9144 1.9 44.5 4210 81
800 AMA 450L8A VSD10119 742 96.0 0.83 839 313 10296 2.0 49.7 4460 81
900 AMA 500L8A VSD10120 743 96.2 0.84 934 345 11563 2.0 74 5390 81
1000 AMA 500L8A VSD10121 743 96.3 0.84 1037 379 12848 2.0 78.4 5550 81
1120 AMA 500L8A VSD10122 743 96.4 0.83 1165 432 14389 2.0 82.7 5700 81
1250 AMA 500L8A VSD10123 744 96.6 0.84 1289 487 16044 2.2 100.1 6320 81
Data presented in rating lists are typical values.
Guaranteed values on request. All engineered motors
are optimized for the specified application. Accurate
motor data will be given on request at quotation phase.
Legally binding performance and specification data is
given to the end user once each order is confirmed.

132 ABB/ BU Machines / HV Induction motors IEC catalogue / Motors for variable speed drives EN 05-2006
LV Modular motors 690 V - 50 Hz
Technical data for open weather protected
three phase motors
IP 24W - IC 01 - Insulation class F, temperature rise class B
Efficiency Power factor Current Torque Sound
Full Full IN I0 TN Tmax Rotor Motor pressure
Output Motor Product Speed load load inertia weight level LP
kW type ID r/min 100% 100% A A Nm TN kgm2 kg dB(A)

1500 r/min = 4 poles 690 V 50 Hz


710 AMA 400L4W VSD10047 1486 96.1 0.86 720 237 4563 2.1 14.8 2980 82
800 AMA 400L4W VSD10048 1485 96.2 0.88 788 213 5143 2.0 16.8 3180 82
900 AMA 400L4W VSD10049 1486 96.4 0.88 893 267 5783 2.2 17.8 3300 82
1000 AMA 400L4W VSD10050 1484 96.3 0.89 976 220 6437 1.8 18.8 3400 82
1120 AMA 450L4W VSD10051 1487 96.3 0.86 1129 330 7191 1.9 27.4 3930 82
1250 AMA 450L4W VSD10052 1488 96.6 0.87 1240 344 8022 2.0 30.8 4190 82
1400 AMA 450L4W VSD10053 1489 96.7 0.87 1389 415 8977 2.2 34.3 4420 82
1600 AMA 500L4W VSD10054 1491 96.7 0.89 1548 396 10251 2.2 52.6 5380 83
1800 AMA 500L4W VSD10055 1489 96.7 0.90 1727 337 11547 1.9 55.5 5540 83
2000 AMA 500L4W VSD10056 1491 97.0 0.91 1904 449 12809 2.3 64.3 6030 83
2240 AMA 500L4W VSD10057 1490 97.0 0.91 2134 449 14358 2.1 64.3 6030 83

1000 r/min = 6 poles 690 V 50 Hz


500 AMA 400L6W VSD10058 987 95.5 0.84 523 182 4836 1.8 16.5 2910 81
560 AMA 400L6W VSD10059 987 95.7 0.85 576 178 5416 1.7 18.9 3100 81
630 AMA 400L6W VSD10060 988 95.8 0.84 654 229 6086 1.9 20.1 3170 81
710 AMA 400L6W VSD10061 988 95.8 0.85 734 247 6862 1.8 21.3 3270 81
800 AMA 400L6W VSD10062 988 95.9 0.84 827 275 7733 1.8 22.5 3380 81
900 AMA 450L6W VSD10063 989 96.2 0.87 900 270 8689 2.0 34.6 3940 81
1000 AMA 450L6W VSD10064 990 96.3 0.87 1005 321 9650 2.1 36.8 4070 81
1250 AMA 450L6W VSD10066 988 96.3 0.88 1230 296 12084 1.8 43.3 4440 81
1328 AMA 450L6W VSD10065 988 96.2 0.88 1320 340 12841 1.8 41.1 4310 81
1400 AMA 500L6W VSD10067 989 96.5 0.88 1376 334 13514 1.8 63.4 5350 82
1600 AMA 500L6W VSD10068 990 96.7 0.88 1579 438 15430 2.0 67.0 5500 82
1800 AMA 500L6W VSD10069 991 96.8 0.88 1763 479 17349 2.0 77.5 5940 82
2000 AMA 500L6W VSD10070 990 96.7 0.88 1960 479 19300 1.8 77.5 5940 82

750 r/min = 8 poles 690 V 50 Hz


315 AMA 400L8W VSD10071 738 94.8 0.81 344 135 4073 1.8 18.3 2870 81
355
400
450
AMA 400L8W
AMA 400L8W
AMA 400L8W
VSD10072
VSD10073
VSD10074
740
740
740
95.2
95.3
95.3
0.80
0.80
0.81
388
439
490
162
188
204
4582
5161
5806
2.0
2.0
2.0
21.1
22.4
25.2
3070
3160
3330
81
81
81
3
500 AMA 400L8W VSD10075 740 95.3 0.81 541 217 6455 1.9 26.5 3430 81
560 AMA 450L8W VSD10076 741 95.9 0.83 589 219 7212 1.9 37.1 3780 81
630 AMA 450L8W VSD10077 742 96.0 0.82 666 261 8108 2.0 39.7 3910 81
710 AMA 450L8W VSD10078 741 95.9 0.83 744 272 9144 1.9 42.3 4000 81
800 AMA 450L8W VSD10079 741 96.0 0.84 834 288 10309 1.8 44.9 4130 81
900 AMA 450L8W VSD10080 742 96.2 0.83 942 350 11585 1.9 50.1 4380 81
1000 AMA 500L8W VSD10081 742 96.3 0.84 1029 345 12862 1.8 70.6 5140 81
1120 AMA 500L8W VSD10082 742 96.4 0.84 1151 379 14408 1.8 75.0 5300 81
1250 AMA 500L8W VSD10083 742 96.4 0.84 1289 432 16079 1.8 79.3 5450 81
1400 AMA 500L8W VSD10084 742 96.5 0.85 1428 444 18013 1.7 88.0 5760 81

Data presented in rating lists are typical values.


Guaranteed values on request. All engineered motors
are optimized for the specified application. Accurate
motor data will be given on request at quotation phase.
Legally binding performance and specification data is
given to the end user once each order is confirmed.

ABB/ BU Machines / HV Induction motors IEC catalogue / Motors for variable speed drives motors EN 05-2006 133
LV Modular motors 690 V - 50 Hz
Technical data for totally enclosed squirrel
cage three phase motors
IP 55 - IC 81W - Insulation class F, temperature rise class B
Efficiency Power factor Current Torque Sound
Full Full IN I0 TN Tmax Rotor Motor pressure
Output Motor Product Speed load load inertia weight level LP
kW type ID r/min 100% 100% A A Nm TN kgm2 kg dB(A)

1500 r/min = 4 poles 690 V 50 Hz


710 AMA 400L4L VSD10047 1486 96.1 0.86 720 237 4563 2.1 14.8 2980 80
800 AMA 400L4L VSD10048 1485 96.2 0.88 788 213 5143 2.0 16.8 3180 80
900 AMA 400L4L VSD10049 1486 96.4 0.88 893 267 5783 2.2 17.8 3300 80
1000 AMA 400L4L VSD10050 1484 96.3 0.89 976 220 6437 1.8 18.8 3400 80
1120 AMA 450L4L VSD10051 1487 96.3 0.86 1129 330 7191 1.9 27.4 3930 80
1250 AMA 450L4L VSD10052 1488 96.6 0.87 1240 344 8022 2.0 30.8 4190 80
1400 AMA 450L4L VSD10053 1489 96.7 0.87 1389 415 8977 2.2 34.3 4420 80
1600 AMA 500L4L VSD10054 1491 96.7 0.89 1548 396 10251 2.2 52.6 5380 80
1800 AMA 500L4L VSD10055 1489 96.7 0.90 1727 337 11547 1.9 55.5 5540 80
2000 AMA 500L4L VSD10056 1491 97.0 0.91 1904 449 12809 2.3 64.3 6030 80
2240 AMA 500L4L VSD10057 1490 97.0 0.91 2134 449 14358 2.1 64.3 6030 80

1000 r/min = 6 poles 690 V 50 Hz


500 AMA 400L6L VSD10058 987 95.5 0.84 523 182 4836 1.8 16.5 2910 80
560 AMA 400L6L VSD10059 987 95.7 0.85 576 178 5416 1.7 18.9 3100 80
630 AMA 400L6L VSD10060 988 95.8 0.84 654 229 6086 1.9 20.1 3170 80
710 AMA 400L6L VSD10061 988 95.8 0.85 734 247 6862 1.8 21.3 3270 80
800 AMA 400L6L VSD10062 988 95.9 0.84 827 275 7733 1.8 22.5 3380 80
900 AMA 450L6L VSD10063 989 96.2 0.87 900 270 8689 2.0 34.6 3940 80
1000 AMA 450L6L VSD10064 990 96.3 0.87 1005 321 9650 2.1 36.8 4070 80
1250 AMA 450L6L VSD10066 988 96.3 0.88 1230 296 12084 1.8 43.3 4440 80
1328 AMA 450L6L VSD10065 988 96.2 0.88 1320 340 12841 1.8 41.1 4310 80
1400 AMA 500L6L VSD10067 989 96.5 0.88 1376 334 13514 1.8 63.4 5350 80
1600 AMA 500L6L VSD10068 990 96.7 0.88 1579 438 15430 2.0 67.0 5500 80
1800 AMA 500L6L VSD10069 991 96.8 0.88 1763 479 17349 2.0 77.5 5940 80
2000 AMA 500L6L VSD10070 990 96.7 0.88 1960 479 19300 1.8 77.5 5940 80

750 r/min = 8 poles 690 V 50 Hz


315 AMA 400L8L VSD10071 738 94.8 0.81 344 135 4073 1.8 18.3 2870 80

3 355
400
450
AMA 400L8L
AMA 400L8L
AMA 400L8L
VSD10072
VSD10073
VSD10074
740
740
740
95.2
95.3
95.3
0.80
0.80
0.81
388
439
490
162
188
204
4582
5161
5806
2.0
2.0
2.0
21.1
22.4
25.2
3070
3160
3330
80
80
80
500 AMA 400L8L VSD10075 740 95.3 0.81 541 217 6455 1.9 26.5 3430 80
560 AMA 450L8L VSD10076 741 95.9 0.83 589 219 7212 1.9 37.1 3780 80
630 AMA 450L8L VSD10077 742 96.0 0.82 666 261 8108 2.0 39.7 3910 80
710 AMA 450L8L VSD10078 741 95.9 0.83 744 272 9144 1.9 42.3 4000 80
800 AMA 450L8L VSD10079 741 96.0 0.84 834 288 10309 1.8 44.9 4130 80
900 AMA 450L8L VSD10080 742 96.2 0.83 942 350 11585 1.9 50.1 4380 80
1000 AMA 500L8L VSD10081 742 96.3 0.84 1029 345 12862 1.8 70.6 5140 80
1120 AMA 500L8L VSD10082 742 96.4 0.84 1151 379 14408 1.8 75.0 5300 80
1250 AMA 500L8L VSD10083 742 96.4 0.84 1289 432 16079 1.8 79.3 5450 80
1400 AMA 500L8L VSD10084 742 96.5 0.85 1428 444 18013 1.7 88.0 5760 80

Data presented in rating lists are typical values.


Guaranteed values on request. All engineered motors
are optimized for the specified application. Accurate
motor data will be given on request at quotation phase.
Legally binding performance and specification data is
given to the end user once each order is confirmed.

134 ABB/ BU Machines / HV Induction motors IEC catalogue / Motors for variable speed drives EN 05-2006
Engineered motors, HXR, for LV variable speed drives
Dimension drawings
Antifriction bearings, 0 < UN ≤ 1.0 kV, IM 1001, IC411

HXR Poles A B C D E F H AE HD L K LD LE

400S 2 686 560 280 70 140 20 400 930 1140 1505 35 1080 380
400S ≥4 686 560 280 100 210 28 400 930 1140 1670 35 1150 450
400L 2 710 900 224 80 170 22 400 975 1185 1765 35 1325 430
400L ≥4 710 900 224 110 210 28 400 975 1185 1900 35 1365 470
450L 2 800 1000 250 80 170 22 450 1025 1290 1985 42 1520 445
450L ≥4 800 1000 250 110 210 28 450 1025 1290 2120 42 1560 485
500L 2 900 1250 280 90 170 25 500 1265 1530 2320 42 1800 460
500L ≥4 900 1250 280 120 210 32 500 1265 1530 2455 42 1840 500
560L ≥4 1000 1600 400 160 300 40 560 1340 1675 3025 48 2350 630

HXR Poles AA AB AC BA BB HA D-end bearing N-end bearing 3


400S 2 160 780 745 210 886 100 6317M/C3 6317M/C3
400S ≥4 160 780 745 210 886 100 6322/C3 6319/C3
400L 2 140 840 840 260 1120 35 6317M/C3 6317M/C3
400L ≥4 140 840 840 260 1120 35 6324/C3 6319/C3
450L 2 160 950 940 320 1300 40 6317M/C3 6317M/C3
450L ≥4 160 950 940 320 1300 40 6324/C3 6322/C3
500L 2 170 1050 1050 375 1570 45 6319M/C3 6319M/C3
500L ≥4 170 1050 1050 375 1570 45 6326/C3 6324/C3
560L ≥4 230 1170 1195 620 1940 50 6034/C3 + NU1034/C3 NU322/C3

The above table gives the main dimensions in mm.


The customer is responsible for the preparation of the
foundation. Certified outline drawing is delivered with each
purchase order. The motor's rotational direction will be as
specified in the order.

ABB/ BU Machines / HV Induction motors IEC catalogue / Motors for variable speed drives EN 05-2006 135
Engineered motors, HXR, for LV variable speed drives
Dimension drawings
Antifriction bearings, 0 < UN ≤ 1.0 kV, IM 3011, IC411

HXR Poles M N P S D E F G GD L LA LD

400S 2 740 680 800 23 70 140 20 62.5 12 1505 25 395


400S ≥4 740 680 800 23 100 210 28 90 16 1670 25 465
400L 2 940 880 1000 28 80 170 22 71 14 1765 30 425
400L ≥4 940 880 1000 28 110 210 28 100 16 1900 30 465
450L ≥4 1080 1000 1150 28 110 210 28 100 16 2120 30 480
500L ≥4 1080 1000 1150 28 120 210 32 109 18 2455 30 510
560L ≥6 1320 1250 1400 28 160 300 40 147 22 3005 40 630

HXR Poles LE LF T AC AD AE HD D-end bearing N-end bearing

3 400S
400S
2
≥4
1080
1150
130
130
6
6
750
750
880
880
785
785
1280
1280
6317M/C3
6322C3
7317 BM
7319 B
400L 2 1318 150 6 840 925 830 1425 6317M/C3 7317 BM
400L ≥4 1358 150 6 840 925 830 1425 6324/C3 7319 B
450L ≥4 1555 180 6 940 975 880 1550 6324/C3 7322 B
500L ≥4 1850 200 6 1040 1175 1020 1750 6326/C3 7324 B
560L ≥6 2350 250 6 1190 1260 1170 1965 6034/C3 7334 B

The above table gives the main dimensions in mm.


The customer is responsible for the preparation of the
foundation. Certified outline drawing is delivered with each
purchase order. The motor's rotational direction will be as
specified in the order.

136 ABB/ BU Machines / HV Induction motors IEC catalogue / Motors for variable speed drives EN 05-2006
Engineered motors, AMA, for LV variable speed drives
Dimension drawings
Antifriction bearings, 0 < UN ≤ 1.0 kV, IM 1001, IC01 / IP24W

AMA Poles A B C D E F G H K L AA AB AC AD

400L 2 750 1250 200 85 170 22 76 400 35 1825 150 880 920 380
400L ≥4 750 1250 200 110 210 28 100 400 35 1865 150 880 920 380
450L 2 850 1400 200 90 170 25 81 450 42 1975 150 980 970 380
450L ≥4 850 1400 200 125 210 32 114 450 42 2025 150 980 970 380
500L ≥4 950 1600 200 140 250 36 128 500 42 2305 150 1080 1145 505

AMA Poles AE BA BB BC GD HA HB HC LD LE HU D-end bearing N-end bearing

400L 2 1470 545 1450 445 14 20 50 1710 615 1480 565 6319M/C3 6319M/C3
≥4
400L
450L
450L
2
≥4
1470
1570
1570
545
575
575
1450
1600
1600
445
465
465
16
14
18
20
25
25
50
150
150
1710
1860
1860
655
710
750
1520
1630
1670
565
665
665
6324/C3
6319M/C3
6326/C3
6319/C3
6319M/C3
6322/C3
3
500L ≥4 1785 645 1800 495 20 35 60 2060 860 1910 765 6330/C3 6324/C3

The above table gives the main dimensions in mm.


The customer is responsible for the preparation of the
foundation. Certified outline drawing is delivered with each
purchase order. The motor's rotational direction will be as
specified in the order.

ABB/ BU Machines / HV Induction motors IEC catalogue / Motors for variable speed drives EN 05-2006 137
Engineered motors, AMA, for LV variable speed drives
Dimension drawings
Antifriction bearings, 0 < UN ≤ 1.0 kV, IM 4011, IC01 / IP24W

AMA Poles M N P S D E F G HD L LA LD LE

400L ≥4 1080 1000js6 1130 28 110 210 28 100 1875 1865 30 655 1065
450L ≥4 1180 1120h8 1230 28 125 210 32 114 2025 2020 40 750 1215
500L ≥4 1320 1250h8 1370 28 140 250 36 128 2245 2290 47 860 1265

AMA Poles T AC AD AE GD HU D-end bearing N-end bearing

400L ≥4 6 915 820 1480 16 50 6324/C3 7319B


450L ≥4 7 965 870 1580 18 50 6326/C3 7322B
500L ≥4 8 1140 1045 1825 20 50 6330/C3 7324B

The above table gives the main dimensions in mm.


The customer is responsible for the preparation of the
foundation. Certified outline drawing is delivered with each
purchase order. The motor's rotational direction will be as
specified in the order.

138 ABB/ BU Machines / HV Induction motors IEC catalogue / Motors for variable speed drives EN 05-2006
Engineered motors, AMA, for LV variable speed drives
Dimension drawings
Antifriction bearings, 0 < UN ≤ 1.0 kV, IM 1001, IC81W / IP55

AMA Poles A B C D E F G H K L AA AB AC AD

400L 2 750 1250 200 85 170 22 76 400 35 1825 150 880 920 380
400L ≥4 750 1250 200 110 210 28 100 400 35 1865 150 880 920 380
450L 2 850 1400 200 90 170 25 81 450 42 1975 150 980 970 380
450L ≥4 850 1400 200 125 210 32 114 450 42 2025 150 980 970 380
500L ≥4 950 1600 200 140 250 36 128 500 42 2305 150 1080 1140 505

AMA Poles AE BA BB BC GD HA HB HC LD LE HU D-end bearing N-end bearing

400L 2 1470 545 1450 445 14 20 50 1670 615 1480 565 6319M/C3 6319M/C3
≥4
400L
450L
450L
2
≥4
1470
1570
1570
545
575
575
1450
1600
1600
445
465
465
16
14
18
20
25
25
50
150
150
1670
1870
1870
655
710
750
1520
1630
1670
565
665
665
6324/C3
6319M/C3
6326/C3
6319/C3
6319M/C3
6322/C3
3
500L ≥4 1785 645 1800 495 20 35 60 2070 860 1910 765 6330/C3 6324/C3

The above table gives the main dimensions in mm.


The customer is responsible for the preparation of the
foundation. Certified outline drawing is delivered with each
purchase order. The motor's rotational direction will be as
specified in the order.

ABB/ BU Machines / HV Induction motors IEC catalogue / Motors for variable speed drives EN 05-2006 139
Engineered motors, AMA, for LV variable speed drives
Dimension drawings
Antifriction bearings, 0 < UN ≤ 1.0 kV, IM 4011, IC81W / IP55

AMA Poles M N P S D E F G HD L LA LD LE

400L ≥4 1080 1000js6 1130 28 110 210 28 100 1835 1865 30 655 1065
450L ≥4 1180 1120h8 1230 28 125 210 32 114 2035 2020 40 750 1215
500L ≥4 1320 1250h8 1370 28 140 250 36 128 2255 2290 47 860 1265

AMA Poles T AC AD AE GD HU D-end bearing N-end bearing

400L ≥4 6 915 820 1480 16 50 6324/C3 7319B


450L ≥4 7 965 870 1580 18 50 6326/C3 7322B
500L ≥4 8 1140 1045 1825 20 50 6330/C3 7324B

The above table gives the main dimensions in mm.


The customer is responsible for the preparation of the
foundation. Certified outline drawing is delivered with each
purchase order. The motor's rotational direction will be as
specified in the order.

140 ABB/ BU Machines / HV Induction motors IEC catalogue / Motors for variable speed drives EN 05-2006
Engineered motors, AMA, for LV variable speed drives
Dimension drawings
Antifriction bearings, 0 < UN ≤ 1.0 kV, IM 1001, IC611 / IP55

AMA Poles A B C D E F G H K L AA AB AC AD

400L 2 750 1250 200 85 170 22 76 400 35 2290 150 880 920 380
400L ≥4 750 1250 200 110 210 28 100 400 35 2330 150 880 920 380
450L 2 850 1400 200 90 170 25 81 450 42 2480 150 980 970 380
450L ≥4 850 1400 200 125 210 32 114 450 42 2520 150 980 970 380
500L ≥4 950 1600 200 140 250 36 128 500 42 2830 150 1080 1140 505

AMA Poles AE BA BB BC GD HA HB HC LD LE HU D-end bearing N-end bearing

400L 2 1470 545 1450 445 14 20 50 1590 615 1480 565 6319M/C3 6319M/C3
400L
450L
450L
≥4
2
≥4
1470
1570
1570
545
575
575
1450
1600
1600
445
465
465
16
14
18
20
25
25
50
150
150
1590
1760
1760
655
710
750
1520
1630
1670
565
665
665
6324/C3
6319M/C3
6326/C3
6319/C3
6319M/C3
6322/C3
3
500L ≥4 1785 645 1800 495 20 35 60 1960 860 1910 765 6330/C3 6324/C3

The above table gives the main dimensions in mm.


The customer is responsible for the preparation of the
foundation. Certified outline drawing is delivered with each
purchase order. The motor's rotational direction will be as
specified in the order.

ABB/ BU Machines / HV Induction motors IEC catalogue / Motors for variable speed drives EN 05-2006 141
Engineered motors, AMA, for LV variable speed drives
Dimension drawings
Antifriction bearings, 0 < UN ≤ 1.0 kV, IM 4011, IC611 / IP55

AMA Poles M N P S D E F G HD L LA LD LE

400L ≥4 1080 1000js6 1130 28 110 210 28 100 1755 2330 30 655 1065
450L ≥4 1180 1120h8 1230 28 125 210 28 114 1925 2520 40 750 1215
500L ≥4 1320 1250h8 1370 28 140 250 28 128 2145 2830 47 860 1265

AMA Poles T AC AD AE GD HU D-end bearing N-end bearing

400L ≥4 6 915 820 1480 16 50 6324/C3 7319B


450L ≥4 7 965 870 1580 18 50 6326/C3 7322B
500L ≥4 8 1140 1045 1825 20 50 6330/C3 7324B

The above table gives the main dimensions in mm.


The customer is responsible for the preparation of the
foundation. Certified outline drawing is delivered with each
purchase order. The motor's rotational direction will be as
specified in the order.

142 ABB/ BU Machines / HV Induction motors IEC catalogue / Motors for variable speed drives EN 05-2006
ABB Motors’ total product offer
ABB offers several comprehensive ranges of AC motors and generators.
We manufacture synchronous motors for even the most demanding applications,
and a full range of low and high voltage induction motors.
Our in-depth knowledge of virtually every type of industrial processing ensures
we always specify the best solution for your needs.

Low voltage motors and generators


General purpose motors for Motors for hazardous areas Other applications
standard applications – Flameproof motors – Permanent magnet motors
– Aluminum motors – Increased safety motors – High speed motors
– Steel motors – Non-sparking motors – Wind turbine generators
– Cast iron motors – Dust ignition proof motors – Smoke venting motors
– Open drip proof motors – Water cooled motors
– Global motors Marine motors – Motors for roller table drives
– Brake motors – Aluminum motors
– Single phase motors – Steel motors
– Cast iron motors
Process performance motors for – Open drip proof motors
more demanding applications
– Aluminum motors
– Cast iron motors
– Motors for high ambient temperatures

NEMA motors

High voltage and synchronous motors and generators


– High voltage cast iron motors
– Induction modular motors
– Slip ring motors
– Motors for hazardous areas
– Servomotors
– Synchronous motors and generators
– DC motors and generators

ABB/ BU Machines / HV Induction motors IEC catalogue EN 05-2006 143


Printed in Finland, 05-2006/3.000,Waasa Graphics Oy
ABB (www.abb.com) is a leader in power and automation
technologies that enable utility and industry customers to improve
their performance while lowering environmental impact. The ABB
Group of companies operates in around 100 countries and employs
about 104,000 people.

ABB's web site provides further information, including a


library of documents. Visit www.abb.com/motors&drives.

www.abb.com/motors&drives
> Motors
>> High Voltage Induction Motors
>>> Cast Iron Motors, HXR
>>> Process Performance Cast Iron Motors
>>> Induction Motors, Modular

Catalogue BU/ HV Induction Motors IEC Catalogue 05-2006

http://www.abb.com/motors&drives