You are on page 1/ 7

SubstiTUBE® Advanced EM T8 DEF | Technical Datasheet

SubstiTUBE® Advanced EM T8 DEF


ST8A-0.6M 8.7W
ST8A-1.2M 17.5W
Benefit:
innovative LED-lamp, easy and safe to use with direct AC
input

Unique design of Dark-end Free to have better light


distribution in fixture

SDCM ≤6, provides excellent light quality

High lumen efficiency: up to 120lm/W

Lower maintenance cost thanks to longer lifetime than


traditional Fluorescent.
Dark-End Free
Quick, simple and safe replacement. Correct operation
temperature --20° … +45°C

Application:
Technical Features • Train Station
• Underground subway
• T8 LED tube made of glass with G13 base • Supermarket, retail store
• Weight: <500g • Parking lot
• Replace for fluorescent T8 tube • Office
• Up to 50.000 h lifetime (L70B50 at Ta=25°C)
• CCT: 3000K, 4000K, 6500K
• Length: 2FT (0.6m) / 4FT(1.2m)

Electrical and photometric data (rated value)


Voltage Frequency Power Lumen CCT PF CRI Beam
[V] [Hz] (100%) Flux(100%) [K] (Ra) Angle
[W] [lm] (C0/180)

ST8A-0.6M 8,7W/865 230V 220-240 50/60 8.7 1050 6500 >0.9 ≥80 >160°

ST8A-0.6M 8,7W/840 230V 220-240 50/60 8.7 1050 4000 >0.9 ≥80 >160°

ST8A-0.6M 8,7W/830 230V 220-240 50/60 8.7 945 3000 >0.9 ≥80 >160°

ST8A-1.2M 17,5W/865 230V 220-240 50/60 17.5 2100 6500 >0.9 ≥80 >160°

ST8A-1.2M 17,5W/840 230V 220-240 50/60 17.5 2100 4000 >0.9 ≥80 >160°

ST8A-1.2M 17,5W/830 230V 220-240 50/60 17.5 1890 3000 >0.9 ≥80 >160°

1. All technical parameters apply to the entire lamp. Because of the complex manufacturing process for light-emitting diodes (LEDs), the specified
typical values for LED technical parameters represent only purely statistical variables. They do not necessarily correspond to the actual technical
parameters for each individual product which can deviate from the typical value. For parameter of Lumen and Watt, production control tolerance with
±10% in delivery.
2. L70B50 is the average operating life of the LED Lamp during which the luminous flux is greater than or equal to 70% of the initial luminous flux, for
50% of the population. The lifetime is estimated at room temperature (25deg C), free air burning, base up position.

SubstiTUBE® Advanced EM T8 DEF– Nov.2019 © LEDVANCE GmbH. All rights reserved 1


SubstiTUBE® Advanced EM T8 DEF | Technical Datasheet

Minimum / Ambient temperature Ta Maximum temperature Tc Storage temperature Ts


Maximum ratings [C°]
ST8A-0.6M 8.7W -20~45°C <75 °C -20°… 80°C

ST8A-1.2M 17.5W -20~45°C <75 °C -20°… 80°C

Models A (mm) B (mm) C (mm) D (mm) Net Weight


(g)
ST8A-0.6M 8.7W
≤589.8 ≤596.9 ≤604 ≤28 <500

ST8A-1.2M 17.5W
≤1199.4 ≤1206.5 ≤1213.6 ≤28 <500

SubstiTUBE® Advanced EM T8 DEF– Nov.2019 © LEDVANCE GmbH. All rights reserved 2


SubstiTUBE® Advanced EM T8 DEF | Technical Datasheet

Safety and application notes

▪ The SubstiTUBE® Advanced EM T8 Tube must be handled with care. Do not operate product in a
damaged condition.
▪ When operating with double side input wiring, SubstiTUBE® Starter has to be inserted to replace
the conventional fluorescent lamp starter. If the conventional starter is not replaced, the
SubstiTUBE® Advanced EM T8 Tube will start blinking and be damaged!
▪ Do not use SubstiTUBE® Advanced EM T8 Tube in luminaires which do not have any
conventional starter or whereby the conventional starter cannot be replaced. Otherwise,
rewiring is needed.
▪ Not suitable for luminaires with serial lamp connection i.e. more than one tube at one magnetic
ballast.
▪ The SubstiTUBE® Advanced EM T8 Tube emits light at a limited angle, unlike
conventional fluorescent tubes in 360° omni-direction.
▪ Due to the light distribution characteristic of the SubstiTUBE® Advanced EM T8 Tube the resulting
luminaires light characteristic is likely to change. It is not guaranteed that e.g. standards for lighting
at working places will be complied with after replacement. A photometric check of the installation is
highly recommended.
▪ The effective energy savings depend on the efficiency of the luminaire setup to be replaced and
should be considered individually in each case. Particularly magnetic ballast losses are reduced
to ohmic losses and are normally only about 1W.
▪ The SubstiTUBE® Advanced EM T8 Tube is protected according to IP20. Applications with
external risk of moisture and dust can be served with an adequately protected luminaire.
▪ SubstiTUBE® Advanced EM T8 Tube products differ in their diameters and geometries from
fluorescent lamps. Their use in open batten luminaires with gaskets is possible if no excessive
force is expended during the fixing. Obtaining the necessary IP protection in open batten
luminaires with gaskets cannot be ensured.
▪ SubstiTUBE® Advanced EM T8 Tube can be driven directly on line voltage. In order to grant a
safe operation mode please refer to the installation instructions for further information.
▪ Photobiological Safety of lamps and lamp systems according to IEC 62471. Risk Group: Exempt
▪ This lamp may not be suitable for use in all applications where a traditional fluorescent lamp has
been used. The temperature range of this lamp is more restricted. In cases of doubt regarding the
suitability of the application the manufacturer of this lamp should be consulted.
▪ This lamp is not suitable to be used in emergency luminaires designed for double-capped
fluorescent lamp(s).

SubstiTUBE® Advanced EM T8 DEF– Nov.2019 © LEDVANCE GmbH. All rights reserved 3


SubstiTUBE® Advanced EM T8 DEF | Technical Datasheet

Installation Guide

1) Retrofitting a CCG luminaire accord. to EN 62776

Replacing fluorescent T8 tube and installed starter by SubstiTUBE® Advanced EM T8


Tube and SubstiTUBE® Starter

Below is an example for typical lamp holder types


✓ Please ensure that the voltage supply is disconnected.
✓ Carefully remove the fluorescent tube and conventional starter according to the lamp
holder type
✓ Insert SubstiTUBE® Advanced EM T8 Tube and SubstiTUBE® Starter properly.

✓ Turn the conventional lamp 90°and take it out of the socket.


✓ Remove the conventional starter by turning it.
✓ Insert and latch the SubstiTUBE® Starter into starter socket.
✓ Insert SubstiTUBE® Advanced EM T8 Tube into socket and locate into position by turning
90⁰.
✓ Check light the emission direction

NOTE:
- If a luminaire contains a power factor correction capacitor, it is recommended to remove
it from the circuit to maintain power factor >0.9. This should only be carried out by a licensed electrician.

SubstiTUBE® Advanced EM T8 DEF– Nov.2019 © LEDVANCE GmbH. All rights reserved


4
SubstiTUBE® Advanced EM T8 DEF | Technical Datasheet

Installation Guide

2) Installation directly on line voltage

SubstiTUBE® Advanced EM T8 Tube may also be driven directly on line voltage. Please
check the L/N markings on the LED tube. In order to grant a safe operation mode
please refer to the installation instructions for further information. Installation must be done
by licensed electricians.

2.1) Two different wiring configurations for single tube

or

2.2) Two different wiring configurations for double tubes.

or

3) Installation of an ECG luminaire with EM tube

WARNING: SubstiTUBE® Advanced EM T8 Tube is not compatible for use with electronic
control gear (ECG). If there is an existing ECG, bypass the ballast and re-wire* according
to “2) Installation directly on line voltage” and diagrams above.

*WARNING: Modifications to the wiring of an existing luminaire must be carried out by


qualified personnel only. Any modifications made to the original luminaire will alter the
safety aspects of the original luminaire; hence compliance certification of the original
luminaire will no longer be applicable to the modified luminaire.

SubstiTUBE® Advanced EM T8 DEF– Nov.2019 © LEDVANCE GmbH. All rights reserved


5
SubstiTUBE® Advanced EM T8 DEF | Technical Datasheet

Installation Guide

CAUTIONS: Installation Instructions for SubstiTUBE ® Advanced EM T8 LED tube

Connect both line (L) and neutral (N) power to one lampholder as below diagram.

Tube side with the marking “AC input” around the cap should be facing the lampholder with mains connection
otherwise the lamps will not be functionally ON, and AC line in might short circuit.

SubstiTUBE® Advanced EM T8 DEF– Nov.2019 © LEDVANCE GmbH. All rights reserved


6
SubstiTUBE® Advanced EM T8 DEF | Technical Datasheet

Ordering Guide

Product EAN-10* EAN-40** S-Unit***

ST8A-0.6M 8,7W/865 230V EM25X1G9APMOSRAM 4058075421509 4058075421516 25X1

ST8A-0.6M 8,7W/840 230V EM25X1G9APMOSRAM 4058075421523 4058075421530 25X1

ST8A-0.6M 8,7W/830 230V EM25X1G9APMOSRAM 4058075421547 4058075421554 25X1

ST8A-1.2M 17,5W/865 230VEM25X1G9APMOSRAM 4058075421561 4058075421578 25X1

ST8A-1.2M 17,5W/840 230VEM25X1G9APMOSRAM 4058075421585 4058075421592 25X1

ST8A-1.2M 17,5W/830 230VEM25X1G9APMOSRAM 4058075421608 4058075421615 25X1

* EAN-10: ordering code for single unit


** EAN-40: ordering code for shipping unit
*** S-Unit: Lamps per shipping unit

Sales and Technical Support


Sales and technical support is given by the local LEDVANCE subsidiaries.
On our worldwide homepage all LEDVANCE subsidiaries are listed with complete address and
phone numbers.

WWW.ledvance.com
WWW.osram-lamps.com/substitube

LEDVANCE GmbH

Head Office:

Parkring 33, 85748


Garching/Munich Data is subject to change without notice.
Germany Please contact LEDVANCE for detailed information

SubstiTUBE® Advanced EM T8 DEF– Nov.2019 © LEDVANCE GmbH. All rights reserved