Technical data

5560A High-Performance Multi-Product Calibrator


5550A Performance Multi-Product Calibrator
5540A Standard Multi-Product Calibrator
5530A Basic Multi-Product Calibrator

5560A: The next generation high-performing calibrator sup-


porting your most demanding workload
Most comprehensive workload coverage, The 5560A Calibrator defines a new class of high-performance
latest technology, intuitive redesigned multi-product calibrator, providing the broadest electrical
front panel, MET/CAL™ compatibility and workload coverage and highest accuracy for calibrating the
much more most demanding modern workloads.
5560A: The most comprehensive workload 5550A: Provides Fluke legacy performance with modern
coverage enhancements
The 5560A calibrates the most popular benchtop
6.5-digit multimeters with better than 4:1 test The 5550A Performance Multi-Product Calibrator enhances
uncertainty ratio (TUR), oscilloscopes to 2 GHz, the 5522A with new calibration ranges optimized to better
and clamp meters to 1500 A. match your existing digital multimeter workload in a modern,
ruggedized instrument with intuitive graphical interface.
Technical improvements include 30 A con-
tinuous current output with no duty cycle and 5540A: Perfectly suited for common electrical workload
synthesized inductance functionality. These with lowest cost of ownership
improvements enable you to calibrate modern The 5540A Standard Multi-Product Calibrator offers perfor-
and full-functional benchtop multimeters and mance to cover todays most common DMM and Scope work-
clamp meters. Oscilloscope bandwidth to 2 GHz load. Verification is easier with performance matched to most
and edge rise time of <175 pS allows the 5560A to popular 4.5 digit DMMs.
handle an even broader workload. A large variety
of thermocouple types and a new thermocouple 5530A: Basic Multi-Product Calibrator for common workload
connector enables easier connection and broad- including power.
ens the temperature workload coverage. The
workload is expanded even further when the The 5530A Basic Multi-Product Calibrator offers analog per-
5560A is used with a 52120A amplifier and appro- formance identical to the 5540A without capabilities to ad-
priate coil to increase the current output to 6000 dress Oscilloscopes. The addition of power extends workload
A, for calibrating high-current devices such as to more "industrial" devices than the 5540A
Rogowski coils.
5550A: Optimized for your multimeter workload
The 5550A Performance Multi-Product Calibrator enhances the
5522A Multi-Product Calibrator with new calibration ranges
optimized to better match your existing digital multimeter
workload in a modern, ruggedized instrument with an intuitive
graphical interface.

It calibrates popular benchtop digital multimeters with improved


test uncertainty ratios (TURs), oscilloscopes to 1 GHz, and clamp
meters to 1500 A with continuous current output with newly
designed Fluke current coils

Technical improvements include 30 A continuous current output,


which reduces wait time during heavy usage. A range redesign The 5560A High-Performance Calibrator extends workload
enables you to calibrate your existing benchtop multimeters with coverage to the most demanding devices including 6.5-digit
greater confidence. A larger variety of thermocouple types and DMMs and Oscilloscopes up to 2 GHz bandwidth
a new thermocouple connector enables easier connection and
broadens the temperature workload coverage. The workload is
expanded even further when the 5550A is used with a 52120A
amplifier to increase the current output to 6000 A, for calibrating
high-current components such as Rogowski coils.

5540A: Standard performance optimized for common


handheld DMMs and Scopes
The 5540A Standard Multi-Product Calibrators has performance
tailored to cover most common handheld DMMs and Scopes.
These performance capabilities reduces the accuracy of
standards needed to verify and adjust the 5540A,decreasing The 5550A Performance Calibrator provides a broad workload
cost of ownership. it calibrates most popular handheld digital coverage well suited for 5.5-digit class multimeters
multimeters with appropriate test uncertainty ratios (TURs),
oscilloscopes to 600 MHz and clamp meters to 1500A with
continuous current output.

Technical improvements include a current range increase from


20 A to 30 A of continuous current output, which reduces wait
time during heavy usage. A range redesign enables you to
calibrate your existing handheld digital multimeters with greater
confidence. A larger variety of thermocouple types and a new
thermocouple connector enables easier connection and broadens
the temperature workload coverage. The workload is expanded
even further when the 5540A is used with the 52120A amplifier to
increase the current output to 6000 A, for calibrating high-current
components such as Rogowski coils. The 5540A Standard Calibrator offers performance to
handheld DMMs and Scopes with lower cost of ownership
5530A: Basic Calibrator
5530A is our Basic calibrator covering handheld DMMs and Power
measurement devices. With performance similar to the 5540A, it is a
good choice for customers that do not need to cover Oscilloscopes.

Match your setup to your application


A variety of options and accessories lets you match your setup
to your applications. An optional portability kit makes the 5560A,
5550A, 5540A or 5530A an excellent fit for on-site or mobile
The 5530A Basic Calibrator offers performance well suited for
calibration. The DMM AUTOCAL Adapter minimizes lead changes handheld DMMs and Power instruments
during digital multimeter calibration, increasing efficiency without
sacrificing and compromising accuracy. The portability kit pro-
vides ruggedized handles and bumpers, including protection for
the front panel with a cover that also acts as storage for cables
and accessories.

2 Fluke Corporation 5560A High-Performance Calibrator, 5550A Performance Calibrator, 5540A Standard Calibrator and 5530A Basic Calibrator
Workload is expanded even further when the
55x0A Family is used with a 52120A Transconduc-
tance Amplifier to increase the current output to
6000 A, for calibrating high-current components
such as Rogowski coils.

52120A Transconductance Amplifier

Key Differences Between Models


Target Workload 5560A 5550A 5540A 5530A
4.5 digit class multimeter, Example: Fluke 87V TUR 4:1 TUR 4:1 TUR 4:1 TUR 4:1
5.5 digit class multimeter, Example: Fluke 8808A TUR 4:1 TUR 4:1
6.5 digit class multimeter, Example: Keysight 34460A TUR 4:1
Best Performance
Range
@95%, ±5°C, 1 year
DCV 0 V to ±1020 V 6 ppm 9 ppm 24 ppm 24 ppm

DCI 0 A to ±30.2 A continuous 78 ppm 85 ppm 100 ppm 100 ppm

ACV 1 mV to 1020 V; 3 Hz to 500 kHz 110 ppm 120 ppm 780 ppm 780 ppm
ACI 10 uA to 30.2 A continuous; 3 Hz to 30 kHz 120 ppm 390 ppm 1600 ppm 1600 ppm
Variable Resistance 0 Ohm to 1200 MOhm 19 ppm 22 ppm 50 ppm 50 ppm
Variable Capacitance 0 pF to 120 mF 0.09% 0.16% 0.19% 0.19%
Variable Inductance 13 uH to 120 H 0.09% 0.16% - -
0.09°C TC; 0.09°C TC; 0.09°C TC; 0.09°C TC;
Temperature 17 TCs 10 RTDs; ITS-90 or IPTS-68 0.002°C RTD 0.002°C RTD 0.002°C RTD 0.002°C RTD
Functional Differences
AC Power (Phase Adj. and PF); Dual Output (DCV-DCV, ACV-ACV) Yes Yes - Yes
Multi-Unit Sync Yes Yes Yes -
Simple Harmonics Yes Yes - Yes
Inductance Yes Yes - -
52120A Control (Closed Loop); Up to 3 or 360 A Yes Yes Yes Yes
Fluke Coil Effective Current Display Yes Yes - -

Extended Volts/Hertz ACV - 70 V at 300 kHz Yes - - -


90 day; 1 year;
Specification Period, 95% and 99% Confidence 90 day; 1 year 1 year 1 year
2 year
Fast Settling Time Yes Yes Yes Yes
Isolated terminal block (DMM Autocal Compatible) Yes Yes Yes Yes
Scope Output Options
600 MHz; 1 600 MHz; 1
Leveled Sine Bandwidth; < 4% @ 2 GHz 600 MHz -
GHz; 2 GHz GHz
Specified VSWR Yes Yes Yes -
Vertical Amplitude (AC & DC) 0 V to 120 V 0 V to 120 V 0 V to 120 V -
Fast Edge < 175 ps < 175 ps < 175 ps -
Time Marker Accuracy 2.5 ppm 2.5 ppm 2.5 ppm -
Pulse Yes Yes Yes -
Impedance Measurement Yes Yes Yes -
Input Overload Yes Yes Yes -

3 Fluke Corporation 5560A High-Performance Calibrator, 5550A Performance Calibrator, 5540A Standard Calibrator and 5530A Basic Calibrator
Calibrate a wide workload of modern test instruments
Simplified Workflow Improvement Summary

Old Method: 5560A:

+
Change Connections Manage Multiple Single Product Uncertainties
Manage Multiple Standards Uncertainties To Manage of 1 instrument

Calibrated Unit Calibrated Unit

• Most common 6.5 digit DMMS require more than Examples of 6.5-digit workloads
5522A or competitive units to calibrate to 4: 1 TUR

• Samples of 6.5 digit workload

• Keysight 34401, 34460A, 34461A


• Keithley DMM6500, 2100
• Fluke 8846A/8845A
• All DMMs to the right can be calibrated with 5560A
without additional equipment and maintain 4: 1 TUR

Calibrating Digital Multimeters


4:1 test uncertainty ratio The 5540A and 5530A Calibrators extend the
The 5560A calibrates a complete range of workload capabilities of the 5502A Multi-Product
electrical workload, but it is especially ideal as Calibrator, improving performance suited for
a 6.5-digit multimeter calibrator, with a 4:1 test real-time demand on-site or mobile calibration.
uncertainty ratio (TUR) for most popular bench- It calibrates most 4.5-digit multimeters with a
top models. 4:1 TUR across its measurement range.

The 5550A is functionally similar to the Fluke A 4:1 TUR enables you to quickly meet or exceed
Calibration 5522A Multi-Product Calibrator; manufacturers’ specifications for calibrating
however, this new model has been enhanced digital multimeters without guardbanding and
with the latest technology and usability features. the need for additional equipment. This simpli-
It calibrates most 5.5-digit multimeters and even fies setup and reduces the number of standards
some 6.5-digit multimeters with a 4:1 TUR across required to calibrate the most demanding digital
its measurement range. multimeters.

4 Fluke Corporation 5560A High-Performance Calibrator, 5550A Performance Calibrator, 5540A Standard Calibrator and 5530A Basic Calibrator
Inductance sourcing expands 5560A and Fast settling time
5550A workload coverage Calibrate multimeters significantly faster with
A new inductance sourcing function expands improved settling time in the 55x0A Family. In
workload coverage to more types of modern some cases, these new calibrators settle 50 %
digital multimeters. faster than previous models. You’ll have less wait
time and more time actually performing the tests.

Digital-to-analog converter design FlukeFluke 5560A:


independent of switch resistance
Fluke 5522A:
A new patented ultra-linear digital-to-analog
design enables the 5560A, 5550A, 5540A and
5530A to achieve performance specifications
that were not possible in the 5522A and 5502A,
allowing you to calibrate a more accurate and
demanding workload.

FASTER!
Optimized ranging for complete
workload coverage
“Ranging” refers to the range over which a
particular specification applies.

In the 5522A and 5502A calibrators, ranging


occurs in multiples of 3.3x; however, most bench
top multimeters typically range at 1.2x. Since
06:21 01:12
ranging was different in these older models, at
some points the calibrator alone is not optimized
to calibrate the digital multimeter at its ideal
High-quality lead set included; optional
specification point. DMM AUTOCAL Adapter for dedicated
multimeter calibration
The 55x0 Family is now optimized to match the The 55x0A Family ship with a Fluke Calibration
range switching of the most popular 6.5-digit, lead set that gives you a high-quality connection,
5.5-digit and 4.5-digit DMMs. These ranging matched to your calibrator.
improvements enable you to calibrate more
of your multimeter workload with a single An optional DMM AUTOCAL Adapter lets
calibrator. you easily dedicate the calibrator to a digital
multimeter workload. The adapter plugs directly
into the calibrator’s output terminals and gives
Re-mapped output terminals limits lead you the same functionality as the included leads
changes but with greater convenience and efficiency,
We’ve re-mapped the output terminals on the reducing user error.
55x0A Family, decoupling Aux and Sense outputs,
making it possible to calibrate most workloads
with minimal lead changes.

The new terminal layout marks a distinct


improvement over older models. The 5522A and
5502A, for example, has shared Sense and AUX
terminals, as well as shared ground and guard,
so you have to change leads frequently during
a multimeter calibration. On the 55x0A Family,
all the terminals are dedicated and the guard
terminal is moved to the side, enabling you to
connect the leads once and complete the meter
calibration efficiently.
Optional DMM AUTOCAL Adapter lets you dedicate the calibrator
to a digital multimeter workload.

5 Fluke Corporation 5560A High-Performance Calibrator, 5550A Performance Calibrator, 5540A Standard Calibrator and 5530A Basic Calibrator
Firmware Functionality Between Models
Function/Feature 5560A 5550A 5540A 5530A
Direct Volts v1.0.x v1.0.x v1.0.x v4.0x
Alternating Volts v1.0.x v1.0.x v1.0.x v4.0x
Direct Current v1.0.x v1.0.x v1.0.x v4.0x
Alternating current v1.0.x v1.0.x v1.0.x v4.0x
Resistance v1.0.x v1.0.x v1.0.x v4.0x
Capacitance v1.0.x v1.0.x v1.0.x v4.0x
Inductance v1.0.x v1.0.x N/A N/A
Temperature(15 TC; 10 RTD) v1.0.x v1.0.x v1.0.x v4.0x
ACV ACI waveforms (Sine, Square) v1.0.x v1.0.x v1.0.x v4.0x
Power (AC, DC) v1.0.x v1.0.x N/A v4.0x
dBm v2.0.x v2.0.x v2.0.x v4.0x
Scope Functions
DC/AC Voltage N/A
Edge N/A
Leveled Sine N/A
Marker N/A
v2.0.x v2.0.x v2.0.x
Waveform Generator Up to Up to Up to N/A
Video 2 GHz 1 GHz 600 MHz N/A
Pulse N/A
Measure Ohms & Capacitance N/A

Overload AC & DC N/A

Dual Output; DCV-DCV, ACV-ACV v2.0.x v2.0.x N/A v4.0x


52120A Support v3.0.x v3.0.x v3.0.x v4.0x
Fluke Coil Effective Current Display v3.0.x v3.0.x N/A N/A
Specification Detail Display v3.0.x v3.0.x v3.0.x v4.0x
Multi-Unit Sync v3.0.x v3.0.x v3.0.x N/A
Simple Harmonics v4.0.x v4.0.x N/A v4.0x
Calibration Report Save v4.0.x v4.0.x v4.0.x v4.0x

55X0A Product Roadmap


Features and functions improve with evolving customer needs

2022 2023 2024 2025 5530A

V1 Firmware V2 Firmware V3 Firmware V4 Firmware 5530A Basic Calibrator


Function/Feature Function/Feature Function/Feature Function/Feature Calibrator with
Direct Volts dBm Units 52120A Support Simple Harmonics • 5540A Functionality
Alternating Volts Scope Functions Fluke Coil Effective Current Calibration Report • 5540A Accuracy
Direct Current DC/AC Voltage Display
Alternating current Edge • Adds Power & Dual Output
Specification Detail Display
Resistance Leveled Sine • No Scope Option
Marker
Multi-Unit Sync
Capacitance
Waveform Generator
Inductance
Video
Temperature(TC, RTD) Pulse
Waveforms (Sine, Square) Measure Ohms & Capacitance
Power(AC, DC) OverloadA C & DC
Dual Output

6 Fluke Corporation 5560A High-Performance Calibrator, 5550A Performance Calibrator, 5540A Standard Calibrator and 5530A Basic Calibrator
Calibrating clamp meters and ammeters
The increased 30 A output enables you to use the 55x0A Family
as a 30 A calibrator for higher current workloads, such as clamp
meters up to 1500 A (with optional current coil).

Continuous output means you don’t need to put the calibrator on


standby for cool down periods while using the current function.
That lets you increase throughput, which can be a real time-saver
if you calibrate a lot of ammeters.

A new optional 1-, 2-, 10-turn current coil and a redesigned 50-turn
current coil work with the 55x0A Family to enable you to calibrate
workload that includes clamp-type current meters and oscilloscope
current probes. Each coil, like the calibrator, is designed for
continuous use at 30 A with a minimum duty cycle which improves
calibration throughput as much as four times.

As an added benefit Effective Current Display on the 5560A and


5550A makes it easy to compare directly with the clamp meter
measurement.

Expand workload coverage even more. Use the 55x0A Family with
the Fluke Calibration 52120A Transconductance Amplifier to increase
the current output to 6000 A, ideal for calibrating high-current
components such as Rogowski coils.

7 Fluke Corporation 5560A High-Performance Calibrator, 5550A Performance Calibrator, 5540A Standard Calibrator and 5530A Basic Calibrator
Calibrate oscilloscopes
Three options provide capabilities to calibrate oscilloscopes to 2 GHz with the 5560A;
1 GHz with the 5550A; or 600 MHz with the 5540A. Easily verify dynamic response,
bandwidth, timing, multiple triggering functions, input resistance and more.

Rise time is a crucial oscilloscope calibration specification. An oscilloscope should


have fast rise time for it to capture rapid transitions; otherwise, the results could be
misleading and significant information may not be displayed. The 5560A, 5550A, and
5540A calibrators feature a faster edge specification to enable coverage of a wide
variety of oscilloscopes. You can accurately source a rapid transition to calibrate
fast edge rise times in modern oscilloscopes. Edge is less than 175 pS, a 58%
improvement from the 5522A calibrator.

The 5560A, 5550A and 5540A also include improved leveled sine wave output. SSB
phase noise is now specified in each model, allowing you to see a more accurate
output signal. The source VSWR is also specified and verified. These improved
specifications, when combined with leveled sine, allow calibration of increasingly
demanding workload.

Using the options to calibrate oscilloscopes lets you simplify operator training
because technicians only need to learn to use one calibrator.

8 Fluke Corporation 5560A High-Performance Calibrator, 5550A Performance Calibrator, 5540A Standard Calibrator and 5530A Basic Calibrator
Oscilloscope Calibration Features
Comparing the 5560A, 5550A, and 5540A
Feature 5560A 5550A 5540A 5530A

600 MHz oscilloscope calibration • • •


option.

1 GHz oscilloscope calibration option • •

2 GHz oscilloscope calibration option •


≤ 175 ps Edge Rise Time • • •
Improved leveled sine wave specifications • • •

5540A Simplifies Maintenance, Reducing Cost of Ownership


5540A Reduces Cost of Ownership with simplified verification and calibration. Verifying the 5540A to it published
specifications is possible with significantly reduced capital equipment compared to the 5560A, 5550A and 5530A,
making it a great choice for users that have self-maintenance needs.

Reverse power protection without false tripping


The 55x0A Family provide reverse power protection and immediate output disconnection on the output terminals for
all functions. The protections apply to external voltages up to 300 Vpk and help protect the calibrator’s internal circuitry
from costly operator error—preventing damage and keeping the calibrator up and running.

1000 V direct amplifier


A newly designed amplifier enables the calibrator to generate low frequency AC voltages without the use of a trans-
former. Reducing weight and increasing settling times.

Optional portability kit


For those who work in the field, the portability kit protects the calibrator and makes it easier to transport. The kit
includes front/rear bumpers and an easy-grip side handle.

A transit case (included) is designed for shipping the calibrator, with or without the portability kit.

The optional portability kit protects the calibrator and makes it easier to transport.

9 Fluke Corporation 5560A High-Performance Calibrator, 5550A Performance Calibrator, 5540A Standard Calibrator and 5530A Basic Calibrator
Visual Connection OPERATE and STANDBY modes
Management™ terminals OPERATE illuminates when the output terminals are
Light up to indicate active terminals, active. STANDBY illuminates when the terminals are
helping you know which connection not active.
to make

Isolated Touch screen display


terminal block Easy-to-read intuitive menu Calculator keyboard
New terminal layout structure lets you access any A simple calculator-style
optimized for digital feature within three button keyboard makes it easy to
multimeter calibration presses or less enter values quickly
with minimal lead changes

Output
units
Select output
units easily after
entering the
value

Multiplier
keys
These keys let
you conveniently
step a measure-
ment up or down

Thermocouple Trigger Scope output USB Output dial


connector BNC connector is Type N connector Calibration reports To adjust the reading, simply
New thermocouple used to trigger the is used for outputs can be stored on USB rotate the output dial and the
connector lets you connect oscilloscope during during oscilloscope memory sticks for error is displayed directly in
multiple types of thermocouple oscilloscope calibra- calibrations. Active easy transfer to a PC ppm or percent
types, including bare wire. tions. Active with with option installed
option installed (not (not on 5530A)
on 5530A)

Power switch Internal circuit boards


A power switch automatically senses Internal printed circuit boards
and adapts to the incoming mains feature the latest digital design
power and frequency technology

Multi-interface Compatibility
Ethernet, RS-232, GPIB Compatible with the Fluke
and USB interfaces Calibration 52120A Amplifier

10 Fluke Corporation 5560A High-Performance Calibrator, 5550A Performance Calibrator, 5540A Standard Calibrator and 5530A Basic Calibrator
Features you expect from a modern instrument

Front and rear panel improvements


Visual Connection Management™ output
terminals light up to indicate which terminals are
active, guiding the user to make the correct con-
nections and reducing user error.

USB ports are placed both on the front and rear


of the unit. Use the port at the front to download
internal calibration constants (requires v4 firm-
ware or greater); use the rear port for remote
communication with a PC—or choose the LAN,
IEEE or serial interfaces.

For previous 5522A and 5502A users, the


5560A, 5550A, 5540A and 5530A maintain many
front-panel details that characterize their prede-
cessors, including the calculator-style keyboard Visual Connection Management output terminals guide the user to make the
for entering values easily, an output dial for correct connections.
varying output and keys for selecting common
parameters with a single touch.

Graphical user interface optimized for


touchscreen use
A 17.8 centimeter (7-inch) graphical user interface
offers intuitive menus that are easy to navigate
and read, providing access to common func-
tions with the touch of a finger and eliminating
the menu scrolling that was required in previous
5522A and 5502A models.

The screen displays all of the information you


need for each parameter you’re calibrating,
with color-coded fields that make it easy to see
where you enter data. The menu is simplified and
USB ports are placed on the front and rear for downloading constants and remote
functions are laid out consistently so that once PC communication.
you learn how to operate one you know how to
operate them all. Training new users just became
much easier.

Status indicators for OPERATE, STANDBY, and


HAZARDOUS VOLTAGE appear on the screen in
bright letters or icons you can recognize from
across the calibration lab.

The touch screen interface is available in nine


languages, including English, French, German,
Spanish, Japanese, Chinese, Portuguese, Russian
and Korean.

The graphical user interface lets you navigate easily with the touch of a finger.

11 Fluke Corporation 5560A High-Performance Calibrator, 5550A Performance Calibrator, 5540A Standard Calibrator and 5530A Basic Calibrator
Automating calibration with MET/CAL software increases throughput and efficiency. Hundreds of procedures are available for the 5560A, 5550A and 5540A.

MET/CAL™ automation increases It is the most complete software solution


throughput and efficiency available for calibration professionals. However, if
you already use a calibration asset management
Quality standards impose stringent requirements system, you can integrate MET/CAL into your
for documenting, reporting, and controlling workflow with MET/CONNECT™ Calibration
calibration processes and results. MET/CAL™ Integration
Calibration Management Software helps you Software. MET/CONNECT is the hub of a fast-
meet these requirements while increasing growing community of mainline calibration
throughput and streamlining voltage calibration, software providers that have partnered
resistance calibration, and current calibration with Fluke Calibration to support MET/CAL
processes. automation. Whatever calibration management
system you use, MET/CONNECT unlocks
MET/CAL™ is a powerful application for creating, calibration and workflow automation in your lab.
editing and testing calibration procedures and
collecting and reporting results on a wide variety
of instruments. As the industry-leading software Priority software support helps you stay
for automated calibration, thousands of calibration productive
procedures have been written to automate a vast MET/SUPPORT Gold is an annual membership
array of calibrations around the world. program offering premium support and services
to help you stay as productive as possible with
The 55x0A Family work with MET/CAL, including
MET/CAL software. Services include free software
hundreds of automated calibration procedures to
updates and upgrades, free access to the Fluke
consistently and dramatically improve throughput.
MET/CAL Warranted Procedures Library, priority
MET/CAL v10.6.2 and later includes a Function
technical support, plus discounts on training
Select Code (FSC) that enables you to add the
and custom procedure development. Members
5560A, 5550A and 5540A seamlessly to your
also receive invitations to regular calibration
existing calibration operations. MET/CAL v11.0.0
software web seminars and user group meet-
adds support for the oscilloscope calibration
ings. Use only a few of the Gold services and you
options. MET/CAL v11.2.0 adds support for the
can easily recover more than the cost of your
5530A.You may purchase MET/CAL with MET/
membership fee.
TEAM™, a dedicated asset management system.

12 Fluke Corporation 5560A High-Performance Calibrator, 5550A Performance Calibrator, 5540A Standard Calibrator and 5530A Basic Calibrator
Your Choice of Specifications

How often to calibrate? You decide.


The 5560A includes 90-day, 1-year, and 2-year specifications, while
the 5550A includes 90-day and 1-year specifications and the 5540A
and 5530A includes 1-year specifications. You can manage the cost of
ownership and maximize uptime by keeping the calibrator in service
as long as possible based on your unique specification requirements.
That means you may not need to calibrate it every year.

Metrology training builds team skills


Calibration and metrology training from Fluke Calibration improves
the knowledge of you and your colleagues in a wide variety of
disciplines. Instructor-led classroom training is available for general
topics in metrology that include both hands-on training and training
in measurement uncertainty, as well as classes on how to use Fluke
Calibration software. On-site training is available for teams with
specific training needs. Instructor-led and self-paced online courses
are available as well.

Fluke Calibration also offers web seminars, events and road shows
on a wide variety of topics. To stay informed about these events,
register online and subscribe to our e-news.

Calibration and repair services keep you up and running


Fluke Calibration offers extensive calibration support and services
to ensure long-term customer satisfaction and return on invest-
ment. Our worldwide network of service centers offers accredited
calibration traceable to national standards. We provide fast, quality
repair services and full support in setting up your calibration lab. Calibration and metrology training includes a variety of
offerings including classroom, online, and on-site.

13 Fluke Corporation 5560A High-Performance Calibrator, 5550A Performance Calibrator, 5540A Standard Calibrator and 5530A Basic Calibrator
Specifications
Comparing the 5560A, 5550A, and 5540A
Function 5560A 5550A 5540A 5530A

Direct voltage 0 V to ± 1020 V

Direct current 0 A to ± 30.2 A

1 mV to 1020 V
Alternating voltage
3 Hz to 500 kHz

10 µA to 30.2 A
Alternating current
3 Hz to 30 kHz

Volt/hertz product 1000 V at 10 kHz/330 V at 100 kHz

Waveforms Sine wave and square wave

Resistance variable 0 Ω to 1200 MΩ

Capacitance variable 0 nF to 120 mF

Inductance variable 12 µH to 120 H - -

Power (dual output – phantom loads) 30.9 kW - 30.9 kW

Oscilloscope bandwidth 2.1 GHz, 1.1 GHz, or 600 MHz 1.1 GHz or 600 MHz 600 MHz -

Phase lock Yes

Phase control 0.01° - 0.01°

Frequency uncertainty <2.5 ppm

Temperature standard ITS-90, IPTS-68

Cu 10 (427), Cu 100 (428), Cu 50 (428), Ni 120 (672), Pt 100 (385), Pt 100 (3916), Pt 100 (3926),
Resistance temperature detectors
Pt 1000 (385), Pt 200 (385), Pt 500 (385)
(RTDs) output
Compensation: off, 2-wire, 4-wire

External frequency reference 10


Yes
MHz

Thermocouples (source and


A1 (BP,A), B, C, D, E, G, J, K, L, N, R, S, T, U, XK, 10 μV/°C, 1 mV/°C
measure) External or internal CJR

Interfaces / Remote commands USB 2.0, Ethernet Telnet, RS-232 and GPIB

Current capability up to 120 A


52120A Amplifier current capability
Current capability up to 360 A with three 52120As (parallel)

14 Fluke Corporation 5560A High-Performance Calibrator, 5550A Performance Calibrator, 5540A Standard Calibrator and 5530A Basic Calibrator
Ordering Information
Models Description
5560A 5560A High-Performance Multi-Product Calibrator

5560A/2G 5560A High-Performance Multi-Product Calibrator + 2.1 GHz Oscilloscope


Calibration Option

5560A/1G 5560A High-Performance Multi-Product Calibrator + 1.1 GHz Oscilloscope


Calibration Option

5560A/600M 5560A High-Performance Multi-Product Calibrator + 600 MHz Oscilloscope


Calibration Option

5550A 5550A Performance Multi-Product Calibrator

5550A/1G 5550A Performance Multi-Product Calibrator + 1.1 GHz Oscilloscope


Calibration Option

5550A/600M 5550A Performance Multi-Product Calibrator +600 MHz Oscilloscope


Calibration Option

5540A 5540A Standard Multi-Product Calibrator

5540A/600M 5540A Standard Multi-Product Calibrator + 600 MHz Oscilloscope


Calibration Option

5530A 5530A Basic Multiproduct Calibrator

All models include full Accredited 17025 Calibration Certificate traceable to


international standards with data.

Optional
accessories Description

55XXA/LEADS Thermocouple and Test Lead Set with Case

55XXA/COIL 10 1, 2 and 10-Turn Current Coil, Includes an Accredited 17025 Calibration Cer-
tificate Traceable to International Standards with Data
55XXA/COIL 50 50-Turn Current Coil, Includes an Accredited 17025 Calibration Certificate
Traceable to International Standards with Data

55XXA/DMMCAL DMM AUTOCAL Adapter

55XXA/PORTKIT 5560A Portability Kit for On-Site Calibrations

55XX/CASE Extra case. 5560A, 5550A and 5540A include hard case

Premium Care Premium Instrument Service Plans available where applicable


Instrument Plans

15 Fluke Corporation 5560A High-Performance Calibrator, 5550A Performance Calibrator, 5540A Standard Calibrator and 5530A Basic Calibrator
Ordering Information
Software Description
MET/CAL/TEAM Software, MET/CAL w/MET/TEAM

MET/CAL-TL License, Additional MET/CAL (TEAM)

MET/CAL/TEAMXP Software, MET/CAL with MET/TEAM Express

MET/CAL-METCON MET/CAL w MET/CONNECT

MET/CAL-MCL License, Additional MET/CAL (MET/CONNECT)

MET/SUPPORT Gold Annual Support Contract for MET/CAL software, including updates and the
procedure library.

MET/SUPPORT Auto-renewing Annual Support Contract for MET/CAL software,


Preferred including updates, the procedure library, and future developments.

Fluke Calibration. Precision, performance, confidence.™