Analog Current Sensors

0-5VDC, 0-10VDC, 4-20mA outputs


Multiple selectable range split-cores
Optional command relay
Fixed ranges on solid-cores
Energy M
E474343

DESCRIPTION APPLICATIONS
Senva analog transducers measure AC current and provide a proportional ▪ Load trending
output for load trending and control. Choose from easy to install split- ▪ Motor control
core or compact solid core. Selectable ranges and optional command ▪ Process control
▪ Fan/Pump status
relay make for a versatile transducer.
▪ Motor load jamming
▪ Lighting load levels

FEATURES

Split-core switch selectable ranges (30, 60, 120A Snap-on command relay for unitary start/
or 5, 10, 20A full scale ranges) stop/status
▪ Makes scaling easy ▪ Reduces the number of installed components…
▪ Reduces inventory saves time and space
▪ No call backs due to mis-sizing ▪ Removable relay facilitates service
0-5VDC, 0-10VDC, 4-20mA loop powered versions Reliable and cost-effective
▪ Versions compatible with any system ▪ Industry leading 7 year limited warranty
Superior split core design for easy installation
▪ Mount sensor without removing conductor for
installation savings
▪ Clamp on conductor with iris or use detachable base
to screw or DIN mount
▪ Larger 0.75” aperture accomodates oversize
conductors
PROUDLY MADE IN USA
7 year limited warranty

LINEAR ANALOG OUTPUT SPECIFICATIONS


Temperature Rating -15-60 ° C
Factory calibrated
30/60/120A 600V RMS. For use on insulated conductors only!
Insulation Class
Use minimum 75 ° C insulated conductor
Frequency Range 50/60Hz
Load
Amps

0A
Sensor
4mA Output 20mA
0 VDC 5/10 VDC

16 | 866-660-8864 | fax 503-296-2529 | www.senvainc.com


CURRENT
SPLIT CORE OPTIONAL RELAY SOLID CORE SOLID CORE

CURRENT
C-234X C-120X Aperture (A) C-130X
Aperture (A) #! Rplace image? Aperture (A)

Analog Series
H
W
L

L: 2.5” H: 0.57” W: 2.23” L: 0.84” H: .72” W: 2.06” L: 1.78” H: .88” W: 1.31” L: 2.27” H: 1.04” W: 1.6”
A: 0.75”x. 0.75” A: 0.30” diameter A: 0.52” diameter
▪ Mount sensor without ▪ Add to 234X series to ▪ Super small—fits ▪ Compact design
removing conductor for get start/stop/status in a anywhere ▪ Aperture accomodates
installation savings single device ▪ Low cost spade terminals
▪ Clamp on conductor with ▪ Reduces the number of
iris, or use detachable base installed components...
toscrew or DIN mount saves time and space
▪ Larger 0.75” apeture ▪ Removable relay
accomodates oversize facilitates service
conductors

ORDERING INFORMATION
SPLIT CORE Range A Output Sensor Power

C-2343 30A, 60A, 120A Selectable 0 - 5 VDC Induced


C-2344 30A, 60A, 120A Selectable 0 - 10 VDC Induced
C-2345 30A, 60A, 120A Selectable 4 - 20mA Loop- powered, 30 VDC
C-2343-L 5A, 10A, 20A Selectable 0 - 5 VDC Induced
C-2345-L 5A, 10A, 20A Selectable 4 - 20mA Loop- powered, 30 VDC
C-2343-200 200A 0 - 5 VDC Induced
C-2344-200 200A 0-10 VDC Induced

SOLID CORE - MINI


C-1203 15 A 0 - 5 VDC Induced
C-1205 15 A 4 - 20mA Loop- powered, 30 VDC
C-1203-L 5A 0 - 5 VDC Induced
C-1303-L 5A 0 - 5 VDC Induced

COMMAND RELAY Contact rating Coil

CR3-24 N.O. 10A @ 125VAC 24VAC/DC 15mA nom.


CR4-24 N.C. 10A @ 125VAC 24VAC/DC 15mA nom.
CR3-12 N.O. 10A @ 125VAC 9-12VDC 30mA nom.
CR4-12 N.C. 10A @ 125VAC 9-12VDC 30mA nom.

TYPICAL WIRING 0-5/10VDC OUTPUT TYPICAL WIRING LOOP 4-20 MA

INSULATED PRIMARY NOTE: Device IS polarity sensitive. INSULATED PRIMARY NOTE: Device IS polarity sensitive.
AC CONDUCTOR AC CONDUCTOR
CONTROLLER CONTROLLER
600VAC MAX 600VAC MAX
v
v

V+
+
AI
+ V+
Scaling:
Scaling: AI
0-15A
0-15A 4-20mA
0-5VDC 12-30VDC
Output - Loop
- Vdc
GND AI

Warning: Refer to installation instructions that accompany


product and heed all safety instructions.

Higher Reliability, Faster Installation, Superior Accuracy | Sense the difference | 17