Datasheet
Profi Line+
Industrial Gigabit Ethernet Ring-Switch
Overview
The Industrial Ethernet Switch Profi Line+ of MICROSENS is a further development of the
successful Profi Line series. With Gigabit Ethernet on all ports combined with the PoE+
functionality the switch offers highest performance. Designed for highest reliability and
shortest recovery times this switch is the first choice for Industrial Ethernet.
The hardware of the Profi Line+ Switch is designed today for future functions, which are
easy to activate with firmware upgrades. This is facilitated by the latest high-
performance switching chipsets in combination with a powerful ARM processor. As an
established, stable operating system, Linux offers a solid foundation for an intelligent,
open and long-term reliable platform.
Highlights
• Highest Gigabit performance with smallest dimensions
• Industrial design for maximum reliability in harsh environments
• Compact design with full Gigabit performance
• PoE+ (max. 30 W) integrated
• Modular SD-card for firmware and configuration
• Flexible firmware architecture for simple software upgrades
• Redundant power inputs
©2013_MICROSENS GmbH & Co. KG_Küferstr. 16_59067 Hamm/Germany_www.microsens.com
Datasheet_Profi Line+_Industrial GBE Ring-Switch Page 2/15
Specifications
Gigabit Ethernet Switch Power-over-Ethernet PoE/PoE+
Fanless Gigabit Ethernet Switch IEEE 802.3af PoE (max. 15 W/Port),
Low power consumption switch- power supply with typ. 48 VDC
chipset, Energy-Efficient Ethernet IEEE 802.3at PoE+ (max. 30 W/Port),
Layer-2+ store-and-forward power supply with typ. 54 VDC
Max. 8.192 MAC-addresses, automatic 4x 10/100/1000Base-T, PoE+ (PSE)
Learning and aging 1x 10/100/1000Base-T, PoE+ (PD)
Jumbo-Frames (max. 10,240 Bytes) Limitation of the total power
consumption of the switch to max.
Energy-Efficient Ethernet 120 W (full power only with suitable
installation conditions)
EEE according to IEEE 802.3az
Reduced power consumption for each Connectors
RJ-45 port up to 80% depending on
the actual requirement Up-/Downlinks (Dual Media-Ports)
2x SFP-Slot 100/1000Base-X
Network Management 2x 10/100/1000Base-T (RJ-45)
Supports all common management Local Ports
standards 5x 10/100/1000Base-T (RJ-45)
High Performance 800 MHz ARM CPU Auto-Negotiation
Linux operating system with fast Auto MDI/MDI-X function for the use
system boot (approx. 20 seconds) of uniform patch cables
Web Manager (HTTP/HTTPS) Power Supply
Telnet/SSH/Console, incl. standard- 3-pin screw pluggable connector for
commands (ping etc.) solid or litz wires
SNMP v1/v2c/v3 with RS-232 Console Port
View-based Access Control Model Serial terminal port for CLI access
(VACM) and User-based Security (outband management)
Model (USM)
RJ-45 connector
Central management platform
USB Extension Port
(NMP Professional / NMP Server)
For optional accessories
IPv4/IPv6 Dual Stack
Alarm Contacts / I/O-Ports
Integrated CLI scripting for the
automation of routine processes Potential free digital input/output
ports
Firmware-, Script- and configuration
files can be loaded, stored and 2x output (relay)
executed direct from the switch 2x input (optocoupler)
Incremental firmware updates
possible Mounting
Modular SD memory card for the Integrated holder for DIN-rails (DIN
configuration, CLI scripts, firmware EN 50022)
©2013_MICROSENS GmbH & Co. KG_Kueferstr. 16_59067 Hamm/Germany_www.microsens.com
Datasheet_Profi Line+_Industrial GBE Ring-Switch Page 3/15
Feature overview network management
IP Stack
Dual Stack Parallel handling of IPv4 and IPv6 protocol.
IPv4 Stack Internet Protocol v4 handling with support of IPv4, ARP, DHCP, ICMP.
RFC 791 (IPv4), RFC 826 (ARP), RFC 792 (ICMP), RFC 2131 (DHCP)
IPv6 Stack Internet Protocol v6 handling with support of IPv6, DHCPv6, ICMPv6, NDP.
RFC 2460/2464/3484/3513 (IPv6), RFC 2462 (Address Configuration), RFC 2463
(ICMPv6), RFC 2461 (Neighbor Discovery Protocol), RFC 3315 (DHCPv6)
Port Control
Administration Port disable, Individual port alias
Ethernet Copper Auto-Negotiation, speed, duplex mode, flow-control, Auto MDI/MDI-X
Ethernet Fiber / Speed, duplex mode, flow-control
SFP
Green IT Latest chip technology supports Energy-Efficient Ethernet (EEE) according to
IEEE Std. 802.3az.
Power-over-Ethernet (PoE)
Function Sourcing of power to connected devices via standard network Twisted-Pair cable
802.3at mode PoE+ voltage is turned on only after powered device (PD) is detected and
classified on port. Output voltage and power is monitored. Port power is shut
down if limits are exceeded.
802.3af mode PoE voltage is turned on only after powered device (PD) is detected and
classified on port. Output voltage and power is monitored. Port power is shut
down if limits are exceeded.
Power Management Power limit can be defined per port and per total device. Additionally the class of
the powered device (PD) can be limited per port.
Standards IEEE Std. 802.3af (Data Terminal Equipment Power via Media Dependent
Interface), IEEE Std. 802.3at (Data Terminal Equipment Power via Media
Dependent Interface).
Switch Functions
Port Monitor Monitor port for the connection of a network protocol analyzer. Traffic of the port
to be analyzed is copied to the monitor port.
RMON counters 17 Integrated counters for detailed traffic analysis and network trouble shooting.
MAC Table Access to table of MAC addresses learned by the switch. Can be filtered per port,
VLAN address type and entry type (dynamic/static).
Virtual LANs (VLANs)
Function Logical structuring of physical networks by adding a Virtual LAN ID (VID) to each
Ethernet packet. Incoming packets are filtered and forwarded according to their
VID. Each port can be configured for Access, Hybrid or Trunk VLAN processing
mode. Independent VLANs out of the full range of 1 to 4095 can be filtered per
device.
Access Mode For the connection of non-VLAN capable end devices (e.g. PCs). Outgoing
packets are send untagged. Incoming packets are tagged with the port default
VLAN ID (PVID).
For the interconnection of VLAN capable switches. Outgoing packets are always
Trunk Mode send tagged. Incoming packets are received tagged. Incoming packets without
VLAN tag are tagged with the port default VLAN ID (PVID).
©2013_MICROSENS GmbH & Co. KG_Kueferstr. 16_59067 Hamm/Germany_www.microsens.com
Datasheet_Profi Line+_Industrial GBE Ring-Switch Page 4/15
Hybrid Mode For the connection of VLAN capable and non-VLAN capable devices on the same
port (e.g. VoIP-phone (tagged) and PC (untagged)). Outgoing packets are sent
tagged, except packets for the port default VLAN ID (PVID), which are untagged.
Incoming packets are received untagged for the port default VLAN (PVID), all
other packets are tagged.
Priority Override VLAN priority code point of incoming packets can be overwritten with the VLAN
specific priority defined in the VLAN filter.
Voice VLAN VLAN ID used by LLDP/CDP to assign VLAN to connected VoIP-phone.
RSTP VLAN VLAN ID used by Spanning Tree instance for BPDU tagging.
Unauthorized VLAN VLAN ID assigned by Port Based Access Control to unauthorized ports
(guest VLAN).
Management VLAN VLAN ID used by the management agent (device internal port).
Standard IEEE Std. 802.1D, IEEE Std. 802.1Q, IEEE Std. 802.1p
Quality of Service (QoS)
Priority Queues 4 priority queues per port.
Prioritization Strict priority (higher priority always first) or weighted fair queuing (8:4:2:1
Scheme highest to lowest).
Layer1 Priority Static priority queue can be assigned for each port.
Layer2 Priority Incoming packets are forwarded according to the priority code point in their
VLAN tag. The 8 VLAN priority code points can be individually mapped on the 4
priority queues.
Layer3 Priority Incoming packets are forwarded according to the value of the DiffServ Codepoint
(IPv4) / TrafficClass (IPv6) in their IP header. Maximum 64 code points are
supported. For each code point the corresponding priority queue can be mapped.
Traffic shaping 5 ingress rate shaping buckets per port. Supports rate and priority based rate
shaping
Standard IEEE Std. 802.1p (VLAN priority code point), RFC 2474/3260 (IPv4 DiffServ/IPv6
Traffic Class)
Spanning Tree Protocol / Ring Protocol
Rapid Spanning Automatic detection of loops and redundant network paths. Single STP instance
Tree (RSTP) running in configurable VLAN. Rapid Spanning Tree Protocol (RSTP) backwards
compatible to Spanning Tree standard (STP).
MSTP Separate STP instances running in configurable VLAN groups.
PVST RSTP per VLAN for one VLAN
MICROSENS Ring MICROSENS Redundant Ring Protocol with ultra-fast recovery time <20 ms
Protocol within MICROSENS Ring topologies.
Multicast Forwarding
IGMP Snooping Snooping of Internet Group Management Protocol (IGMPv1/v2/v3) for IPv4.
Automatic detection and forwarding of IPv4 multicast-streams. Unregistered
packets can be flooded or blocked. Multicast routers can be detected by
discovery or by query message.
Standard RFC 4541 (IGMP)
Real Time Clock (RTC)
Function Internal device clock can be synchronized with external NTP server.
Protocol Simple Network Time Protocol (NTP)
Standard RFC 4330 (NTP)
©2013_MICROSENS GmbH & Co. KG_Kueferstr. 16_59067 Hamm/Germany_www.microsens.com
Datasheet_Profi Line+_Industrial GBE Ring-Switch Page 5/15
Link Layer Discovery Protocol (LLDP)
Function Advertising identity, capabilities, and neighbors on a connected network
segment.
LLDP-MED Media Endpoint Discovery for the auto-discovery of LAN policies.
Standard IEEE Std. 802.1AB (LLDP), ANSI/TIA-1057 (LLDP-MED)
Cisco Discovery Protocol (CDP)
Function CDP v1, v2 for automatic detection of capabilities of neighbor CDP enabled
devices.
Voice VLAN Support of Voice VLAN for configuration of connected Cisco VoIP-phone.
Port Access Control
Function Port-Based Network Access Control with dynamic port VLAN support and fallback
to MAC based authentication methods. Network access is controlled at the port
level. Supports IEEE Std. 802.1X Authentication, RADIUS MAC Authentication,
MAC Locking and forced authorized/unauthorized mode.
Communication EAPOL, RADIUS
Authentication EAP-MD5, EAP-PEAP (inner protocol: MSCHAPv2), EAP-TLS, EAP-TTLS (inner
Protocols protocols: EAP-MD5, EAP-TLS, PAP)
IEEE 802.1X Multiple users can be authenticated using central RADIUS server based on
Authentication username/password or certificate.
RADIUS MAC Multiple users can be authenticated using central RADIUS server based on their
Authentication MAC addresses.
MAC locking Multiple users can be authenticated based on their MAC addresses. Authorized
MAC addresses are stored permanently in the device. They can be configured
manually or automatically by locking the first MAC addresses learned on the port.
Dynamic VLAN RADIUS server can provide user specific VLAN ID using tunnel-attribute in accept
message. Port VLAN is dynamically set accordingly. Unauthorized users may be
placed in an unauthorized VLAN ('guest VLAN') or blocked completely.
IP Address The IP address of the connected user is detected via ARP snooping. User IP
Detection address information can be logged using RADIUS accounting function.
Standard IEEE 802.1X-2004 (Port-Based Network Access Control).
User Login
Function Implements user based and view based authentication and scope limiting.
Supports unlimited number of user/groups and views (limited by system memory
constrains only). Offers ultimate flexibility with precise access control.
Command Line Interface (CLI)
Function Intuitive command-set with auto-complete and redo-buffer. Individual console
prompt string, Console inactivity timeout. Supports full scripting and editing of
script files. Supports color displays. Permits offline configuration as well as
management of an unlimited number of user configuration sets (limited by system
memory constrains only).
Telnet Telnet via TCP/IP port 23.
Secure Shell (SSH) SSH via TCP/IP port 22. Authentication methods RSA, Diffie-Hellman Key
Exchange. Encryption protocols 3DES-CBC, HMAC-SHA1.
Web Manager
Function Integrated Web Manager with graphical user interface (GUI) for device
configuration and administration using standard web browser.
Protocol HTML v4.01,HTTP, HTTPS, Java Script
©2013_MICROSENS GmbH & Co. KG_Kueferstr. 16_59067 Hamm/Germany_www.microsens.com
Datasheet_Profi Line+_Industrial GBE Ring-Switch Page 6/15
Browser Firefox 4.x, IE 8.x, JavaScript support required.
compatibility
Simple Network Management Protocol (SNMP)
SNMPv1/v2c Simple Network Management Protocol v1, v2c (SNMPv1, v2c) to access device
information stored in Management Information Base (MIB). Security provided by
community strings for Set/Get commands and optionally by G6 login scheme.
Traps Traps, Notifications sent to unlimited number of independently configurable
(SNMPv1/v2c) receiver destinations (limited by system memory constrains only). Sending of
message is triggered by internal device status change events.
Event triggers can be configured individually per destination. Test function to
trigger Trap/Notification for simplified configuration check (Web Manager and CLI
only).
SNMPv3 Simple Network Management Protocol v3 (SNMPv3) for secure access to device
information stored in Management Information Base (MIB). SNMPv3 supports data
encryption, User-based Security Model (USM) and View-based Access Control
Model (VACM).
Traps (SNMPv3) Trap/Notification, InformRequest, Response sent to independently configurable
receivers. Sending of message is triggered by internal device status change
events. Informs provide secured messaging by requiring response message Event
triggers can be configured individually per receiver.
MIBs MIB-2, Enterprise-MIB (MICROSENS G6 MIB). File can be downloaded from the
integrated Web Manager.
Standard RFC 1155/1156/1157 (SNMPv1), RFC 1901/1905/1906 (SNMPv2), RFC
3411/3412/3584 (SNMPv3), RFC 2574/3414 (USM), RFC 2575/3415 (VACM)
RADIUS Client
Function RADIUS client via UDP/IP ports 1812 (access), 1813 (accounting) for Remote
Authentication Dial In User Service (RADIUS) server for authorizing user access
and logging of user accounting information.
Redundancy In case of a response timeout, the next RADIUS server is requested.
Standard RFC 2865 (RADIUS), RFC 2866 (Accounting), RFC 2868 (Tunnel Attributes)
Files
Configuration File transfers may be used to upgrade the software or to load configuration files.
The unit supports TFTP, FTP, SFTP, HTTP, HTTPS transfer protocols. Additionally
files may be loaded via DHCP directives.
Firmware Update Software download can be complete or incremental. Individual modules may be
upgraded, normally without influencing service. Flexible system permits
customized upgrade files if required.
Syslog Client
Function Syslog messages are triggered by system events and can be send to unlimited
number of Syslog servers (limited by system memory constrains only).
Standard RFC 5424
Event Manager
Function Mapping of device status changes (Triggers) to actions e.g. sending out SNMP
trap, Syslog message etc.
Customizable Event severity and alert level freely configurable. Event text strings may be
events customized via user interface with developer rights.
Traps and Syslog Unlimited number of trap and/or Syslog receivers. Event may be filtered
individually on a group level.
©2013_MICROSENS GmbH & Co. KG_Kueferstr. 16_59067 Hamm/Germany_www.microsens.com
Datasheet_Profi Line+_Industrial GBE Ring-Switch Page 7/15
IEEE / RFC Standards
RFC 3414 USM
RFC Standards
RFC 3415 VACM
RFC 791 IPv4
RFC 3484 IPv6
RFC 792 ICMP
RFC 3513 IPv6
RFC 826 ARP
RFC 3584 SNMPv3
RFC 1155 SNMPv1
RFC 3810 MLD
RFC 1156 SNMPv1
RFC 4330 NTP
RFC 1157 SNMPv1
RFC 4541 IGMP Snooping
RFC 1901 SNMPv2c
RFC 4604 MLD
RFC 1905 SNMPv2
RFC 5424 Syslog
RFC 1906 SNMPv2
RFC 2131 DHCP IEEE Standards
RFC 2460 IPv6
802.1D-2004 (Rapid) Spanning Tree
RFC 2461 IPv6 Neighbour Discovery
802.1Q-2005 Multiple Spanning Tree
RFC 2462 IPv6 Auto Configuration
802.1p QoS
RFC 2463 ICMPv6
802.1Q VLAN
RFC 2464 IPv6
802.1X Network Access Control
RFC 2474 IPv4 DiffServ
802.1AB LLDP
RFC 2574 USM
802.3i 10Base-T
RFC 2575 VACM
802.3u 100Base-TX
RFC 2865 RADIUS
802.3x Full duplex and flow control
RFC 2866 Accounting
802.3z 1000Base-X
RFC 2868 Tunnel Attributes
802.3ab 1000Base-T
RFC 3260 IPv6 DiffServ
802.3af Power-over-Ethernet
RFC 3315 DHCPv6
802.3at Power-over-Ethernet (PoE+)
RFC 3411 SNMPv3
802.3az Energy-Efficient Ethernet
RFC 3412 SNMPv3
©2013_MICROSENS GmbH & Co. KG_Kueferstr. 16_59067 Hamm/Germany_www.microsens.com
Datasheet_Profi Line+_Industrial GBE Ring-Switch Page 8/15
Interfaces
©2013_MICROSENS GmbH & Co. KG_Kueferstr. 16_59067 Hamm/Germany_www.microsens.com
Datasheet_Profi Line+_Industrial GBE Ring-Switch Page 9/15
Technical Specifications
Switch LED displays
Type Gigabit Ethernet Switch Number Device 10 LEDs
Layer 2+, IEEE 802.3 compliant Port 2 LEDs per port
Performance Store-and-forward LED-modes Dynamic Standard-mode
Full wire-speed, non-blocking Static Standard without flash
on all ports Quiet Only ON- and Sys-LED
Dark all LEDs off
MAC addresses 8.192 addresses, automatic
L-show permanent LED test
learning and aging
Port LEDs (integrated in RJ-45)
Jumbo Frames max. 10.240 Bytes
Ethernet green Link at port.
Flashing at data traffic
Twisted-Pair Ports yellow Port blocked
(via protocol)
Number 7 red Port Access Control
rejected
Type Gigabit Ethernet, Triple Speed off no link
10/100/1000Base-T
PoE green PoE power active
Connector RJ-45 port, shielded yellow PoE not active
red PoE failure
Cable type Twisted-Pair cable, Category off PoE deactivated
5e, impedance 100 Ohm, length
max. 100 m Device LEDs (central)
Flow Control Pause Frames (IEEE 802.3x), System 1 active System activities
configurable (Firmware update)
off Normal operation
Pin out Auto MDI/MDI-X, Auto Polarity
System 2 off Normal operation
Power-over- Power Sourcing Equipment
Ethernet (PSE) IEEE 802.3af/at Power 1/2 green Power supply 1/2 OK
Class 0-4, max. 15 W / 30 W yellow Input voltage too
low/missing
Fiber Ports (SFP slots) Ring 1/2 green Ring 1/2 normal
yellow Ring backup active
Number 2 red Ring backup failure
off Ring deactivated
Type Gigabit Ethernet Signal in 1/2 green activated, no signal
Dual Speed SFP red S1/S2 activated, alarm
100/1000Base-X, support of off inactive
SFP digital diagnostics function
Signal out 1/2 green activated, no signal
Connector LC (SFP transceiver) red S1/S2 activated, alarm
off inactive
Multimode Multimode, 62.5/125µm (280
(MS100200DX) m) or 50/125 µm (550 m)
850nm wavelength Control Panel
-4..-9.5 dBm output power
-18 dBm sensitivity Reset button Reset of the switch, new upload
0 dBm saturation of the latest stored
Single Mode Single Mode, 9/125 µm (10 km) configuration
(MS100210DX) 1310 nm wavelength (direct hardware function)
-3..-9,5 dBm output power Factory button Request of the IP configuration
-20 dBm sensitivity for management, reset back to
-3 dBm saturation factory default settings
Flow Control Pause Frames (IEEE 802.3x),
configurable
©2013_MICROSENS GmbH & Co. KG_Kueferstr. 16_59067 Hamm/Germany_www.microsens.com
Datasheet_Profi Line+_Industrial GBE Ring-Switch Page 10/15
Technical Specifications (continued)
Power Supply Mechanical
Input 24..57 VDC (54 VDC typ.) Dimensions 120.5 x 59.7 x 100.5 mm
(w x d x h, without connectors)
Power Typ. 7 W
Consumption Weight Approx. 790 g (without SFPs)
Connectors 2x 3 pin screw connector
Standards
Power Supply for PoE / PoE+ CE 2004/108/EC (EMV)
Operation 2006/95/EG (Low voltage)
Security EN 60950-1:2011-01
Input 44..57 VDC
PoE: 48 VDC typ. Emitted EN 55022:2011-12
PoE+: 54 VDC typ. interference
Power max. 130 W (incl. PoE+) Immunity EN 55024:2011-09
Consumption
Delivery / Contents
Environmental Conditions Standard Packaging
Temperature Operation -40..+75 °C Package unit 1 pcs.
Storage -40..+85 °C
Weight approx. 1.000 g
Humidity 10..90%, non condensing
Contents 1x PL+ Switch
1x SD memory card
(separate article number)
2x power supply
2x I/O connector
1x Short manual
1x Set stickers with symbols
Ring-Topology
Normal operation
All switches are configured for ring
operation
One switch is assigned as ring master
Ring master cuts the ring logically
Ring error
Switches signalize segment failure via
ethernet (fiber-uplink)
Master gets that information via ethernet
and closes the logical cut
Switches relearn the actual network
topology (MAC-addresses)
Network function is re-established in less
than 50 ms
©2013_MICROSENS GmbH & Co. KG_Kueferstr. 16_59067 Hamm/Germany_www.microsens.com
Datasheet_Profi Line+_Industrial GBE Ring-Switch Page 11/15
Dimensions
Height: 120.5 mm (Without connectors)
Width: 59.7 mm
Depth: 100.5 mm (107.3 mm incl. DIN-rail holder)
©2013_MICROSENS GmbH & Co. KG_Kueferstr. 16_59067 Hamm/Germany_www.microsens.com
Datasheet_Profi Line+_Industrial GBE Ring-Switch Page 12/15
Memory Card
SD Memory Card
The SD memory card is used for the Change of memory card transfers the
permanent storage of configuration, complete device status
script and firmware files. With this Firmware update by memory card
memory card it is possible to transfer a exchange possible
configuration to a new device in case of
a device failure. Fault tolerant journaling file system
Optional it is possible to write an own Industrial grade– long term stability
MAC address to the SD memory card. Encrypted system as security option
This MAC address has priority compared
to the MAC address in the switch. This Only MICROSENS memory cards have
allows having an exact clone of the to be used. Only with this the long
device by swapping the memory card. term stability over the complete
temperature range can be guaranteed.
©2013_MICROSENS GmbH & Co. KG_Kueferstr. 16_59067 Hamm/Germany_www.microsens.com
Datasheet_Profi Line+_Industrial GBE Ring-Switch Page 13/15
Alarm Contacts
Galvanic isolated contacts (2x) Galvanic isolated digital inputs (2x)
The potential free output contacts (I/O The potential free input contacts (I/O in)
out) allows to control external signalling allow the direct monitoring of external
devices to show the alarm and operation systems, e.g. a rack or door monitoring
status. system.
Relay contact, maximum load 2x galvanic isolated, digital input
57 V/1 A
Internal optocoupler, Input voltage 12
Isolation voltage to the device to 57 V DC
1,500 VDC
Isolation voltage 1,500 VDC
Normally open or normally closed
Status monitored via management
contact possible
The signal status is indicated by a
LED
Attention: Not suitable for the direct
connection of 230 V AC devices!
©2013_MICROSENS GmbH & Co. KG_Kueferstr. 16_59067 Hamm/Germany_www.microsens.com
Datasheet_Profi Line+_Industrial GBE Ring-Switch Page 14/15
Gigabit Ethernet Ports
Gigabit Ethernet Ports (RJ-45) 4x Local Ports, PSE (RJ-45)
All Gigabit Ethernet ports are for the These ports additional include PoE+
connection of 10, 100 or 1000 Mbps Power Sourcing Equipment (PSE)
segments via twisted pair cables with RJ- functionality. With this the switch can
45 connectors. supply the connected end devices with
electrical power. This is often used for
The integrated auto negotiation and auto
VoIP-telephones, IP-cameras and WLAN-
crossover functions automatically ensure
Access Points
the best connection method to the end
devices.
1x Local Port, PD (RJ-45) 2x Dual Media Ports (RJ-45/SFP)
This port additional includes a PoE+ These ports can be optionally used with
powered device (PD) input. Via this port twisted pair or fiber cables. For the use
the switch can be supplied with electrical of a fiber cable a suitable SFP must be
power. The power which is not required plugged into the switch.
by the switch itself can be supplied to
The selection of the used media (twisted
the end devices via its PoE+ ports.
pair or fiber) can be made by the
management.
©2013_MICROSENS GmbH & Co. KG_Kueferstr. 16_59067 Hamm/Germany_www.microsens.com
Datasheet_Profi Line+_Industrial GBE Ring-Switch Page 15/15
Order Information
Description Article No.:
Profi Line+ Switch
Industrial Gigabit Ethernet Switch,
5x 10/100/1000Base-T PoE/PoE+ (4x PSE / 1x PD),
MS650919PM
2x Dual Media Ports: 100/1000Base-X SFP-Slot or
10/100/1000Base-T, Power supply input 24..57 VDC
SD memory card 4 GB for MICROSENS PL+-Switches,
MS140890X-4GB
Extended temperature range -25°C up to +85°C
Accessories
Description Article No.:
SFP Transceiver with extended temperature range -25°C up to +85°C
(Fast Ethernet & WDM on request)
SFP Transceiver, Gigabit Ethernet, Digital Diagnostic
MS100200DX
850 nm Multimode, 1000Base-SX, LC duplex
SFP Transceiver, Gigabit Ethernet, Digital Diagnostic
MS100210DX
1310 nm Single mode, 1000Base-LX, LC duplex
SFP Transceiver, Fast Ethernet, Digital Diagnostic
MS100190DX
1310 nm Multimode, 100Base-FX, LC duplex
SFP Transceiver, Fast Ethernet, Digital Diagnostic
MS100191DX
1310 nm Single mode, 100Base-FX, LC duplex
Network Management
NMP Professional – Network Management Platform
MS200160-1
Software incl. one year update license
NMP Standard– Network Management Platform
MS200162-1
Software incl. one year update license
NMP Server – Network Management Platform
MS200164-1
Software incl. one year update license and 5 clients
External Power Supplies for industrial use 24 VDC
DIN Rail Power Supply 24 Watt 24 VDC / 1.0 A,
MS700420
Wide input range 85-264 VAC, 85…375 VDC
DIN Rail Power Supply 60 Watt 24VDC / 2.5 A,
Adjustment range 21..29VDC,
MS700482-24B
Wide input range 90-264VAC, 85..200VDC
for extended temperature range -40..+75°C
External Power Supplies for industrial use with PoE / PoE+ 44..57VDC
DIN Rail Power Supply 60 Watt 48 VDC / 1.25 A,
MS700430
Adjustment range 48..56VDC, Wide input range 85-264 VAC
DIN Rail Power Supplies 192 Watt 48 VDC / 4 A,
MS700467
Adjustment range 48..56VDC, Wide input range 85-264 VAC
DIN Rail Power Supply 60 Watt 48 VDC / 1.25 A,
Adjustment range 41..58VDC,
MS700482-48B
Wide input range 90-264VAC, 85..200VDC
For extended temperature range -40..+75°C
This document in whole or in part may not be duplicated, reproduced, stored or retransmitted without prior written permission of MICROSENS GmbH
& Co. KG. All information in this document is provided ‘as is’ and subject to change without notice. MICROSENS GmbH & Co. KG disclaims any
liability for the correctness, completeness or quality of the information provided, fitness for a particular purpose or consecutive damage.
MICROSENS is a trademark of MICROSENS GmbH & Co. KG. Any product names mentioned herein may be trademarks and/or registered trademarks
of their respective companies. mr/hb/tk/aku MS650919_PL+_DAT_EN_v1.0.0.docx
©2013_MICROSENS GmbH & Co. KG_Kueferstr. 16_59067 Hamm/Germany_www.microsens.com