Patient Name : Mrs.Y.
UDAY Collected : 21/Aug/2025 07:50PM
Age/Gender : 31 Y 0 M 0 D /F Received : 22/Aug/2025 09:54AM
UHID/MR No : DSUY.0000007784 Reported : 22/Aug/2025 11:03AM
Visit ID : DSUYOPV8563 Status : Final Report
Ref Doctor : Dr.SELF Client Name : PCC SURYAPET
IP/OP NO : Center location : ,Nalgonda
DEPARTMENT OF IMMUNOLOGY
Test Name Result Unit Bio. Ref. Interval Method
THYROID PROFILE TOTAL (T3, T4, TSH) , SERUM
TRI-IODOTHYRONINE (T3, TOTAL) 90.5 ng/dL 84.6-202 ECLIA
THYROXINE (T4, TOTAL) 7.84 µg/dL 5.12-14.06 ECLIA
TSH (Ultrasensitive/4thGen) 6.210 µIU/mL 0.270-4.20 ECLIA
Comment:
Bio Ref Range for TSH in uIU/ml (As per American Thyroid
For pregnant females
Association)
First trimester 0.1 - 2.5
Second trimester 0.2 – 3.0
Third trimester 0.3 – 3.0
1. TSH is a glycoprotein hormone secreted by the anterior pituitary. TSH activates production of T3 (Triiodothyronine) and its
prohormone T4 (Thyroxine). Increased blood level of T3 and T4 inhibit production of TSH.
2. TSH is elevated in primary hypothyroidism and will be low in primary hyperthyroidism. Elevated or low TSH in the context of
normal free thyroxine is often referred to as sub-clinical hypo- or hyperthyroidism respectively.
3. Both T4 & T3 provides limited clinical information as both are highly bound to proteins in circulation and reflects mostly inactive
hormone. Only a very small fraction of circulating hormone is free and biologically active.
4. Significant variations in TSH can occur with circadian rhythm, hormonal status, stress, sleep deprivation, medication &
circulating antibodies.
TSH T3 T4 FT4 Conditions
Primary Hypothyroidism, Post Thyroidectomy, Chronic Autoimmune
High Low Low Low
Thyroiditis
Subclinical Hypothyroidism, Autoimmune Thyroiditis, Insufficient Hormone
High N N N
Treatment.
N/Low Low Low Low Secondary and Tertiary Hypothyroidism
Primary Hyperthyroidism, Goitre, Thyroiditis, Drug effects, Early
Low High High High
Pregnancy
Low N N N Subclinical Hyperthyroidism
Low Low Low Low Central Hypothyroidism, Treatment with Hyperthyroidism
Low N High High Thyroiditis, Interfering Antibodies
N/Low High N N T3 Thyrotoxicosis, Non thyroidal causes
Page 1 of 2
SIN No:BM00280550
This test has been performed at Apollo Health and Lifestyle Ltd- Hyderabad.
Patient Name : Mrs.Y. UDAY Collected : 21/Aug/2025 07:50PM
Age/Gender : 31 Y 0 M 0 D /F Received : 22/Aug/2025 09:54AM
UHID/MR No : DSUY.0000007784 Reported : 22/Aug/2025 11:03AM
Visit ID : DSUYOPV8563 Status : Final Report
Ref Doctor : Dr.SELF Client Name : PCC SURYAPET
IP/OP NO : Center location : ,Nalgonda
DEPARTMENT OF IMMUNOLOGY
High High High High Pituitary Adenoma; TSHoma/Thyrotropinoma
*** End Of Report ***
Page 2 of 2
SIN No:BM00280550
This test has been performed at Apollo Health and Lifestyle Ltd- Hyderabad.
Patient Name : Mrs.Y. UDAY Collected : 21/Aug/2025 07:50PM
Age/Gender : 31 Y 0 M 0 D /F Received : 22/Aug/2025 09:54AM
UHID/MR No : DSUY.0000007784 Reported : 22/Aug/2025 11:03AM
Visit ID : DSUYOPV8563 Status : Final Report
Ref Doctor : Dr.SELF Client Name : PCC SURYAPET
IP/OP NO : Center location : ,Nalgonda
TERMS AND CONDITIONS GOVERNING THIS REPORT
1. Reported results are for information and interpretation of the referring doctor or such other medical professionals, who understand
reporting units, reference ranges and limitation of technologies. Laboratories not be responsible for any interpretation whatsoever
2. This is computer generated medical diagnostics report that has been validated by an Authorized Medical Practitioner/Doctor. The
report does not need physical signature.
3. Partial reproduction of this report is not valid and should not be resorted to draw any conclusion.
4. In the case you are not the intended recipient of this report. Please immediately return the same to the concerned issuing desk. Any
disclosure, copy or distribution of any contents of this report, is unlawful and is strictly prohibited.
5. Results delays may occur due to unforeseen circumstances such as non-availability of kits, equipment breakdown, natural calamities,
IT downtime, logistic delays or any other unavoidable event. For certain tests based on analyte stability, criticality of results and in the
interest of patient for having appropriate medical diagnosis, the same test may be outsourced to other accredited laboratory.
6. It is presumed that the tests performed are, on the specimen / sample being to the patient named or identified and the verifications of
particulars have been confirmed by the patient or his / her representative at the point of generation of said specimen
7. The reported results are restricted to the given specimen only. Results may vary from lab to lab and from time to time for the same
parameter for the same patient (within subject biological variation).
8. The patient details along with their results in certain cases like notifiable diseases and as per local regulatory requirements will be
communicated to the assigned regulatory bodies
9. The patient samples can be used as part of internal quality control, test verification, data analysis purposes within the testing scope of
the laboratory.
10. This report is not valid for medico legal purposes. It is performed to facilitate medical diagnosis only
SIN No:BM00280550
This test has been performed at Apollo Health and Lifestyle Ltd- Hyderabad.