SAFETY DATA SHEET SA067020

SURE-VUE® ADENO TEST KIT

SECTION I: IDENTIFICATION
Cat. No. (s) Chemical/Common Name Formula Hazardous
067020-F SURE-VUE® ADENO Mixture Yes

Description
Sure-Vue® Adeno Test Kit is a rapid, visual assay for the presumptive qualitative detection of Adenovirus
serotypes present in eye swabs, nasal and pharyngeal secretions, fecal samples and cell culture supernatant.

The Sure-Vue® Adeno Test Kits are manufactured for Fisher Healthcare by SA Scientific, Ltd.

SA Scientific, Ltd. SDS Coordinator


4919 Golden Quail Telephone Number: (800) 272-2710
San Antonio, Texas 78240 Emergency Phone: (800) 272-2710

SECTION II: HAZARDOUS INFORMATION


Hazards Identification:
Product Hazard Classifications: Not classified as hazardous.
Signal Word: Warning
GHS Pictograms:

Physical Hazards:
 H303 – May be harmful if ingested.  H313 – May cause skin irritation.
 H320 – May cause eye irritation.  Specimen material may contain pathogenic organisms.

Precautionary statements:
 P264 – Wash hands and exposed area thoroughly after handling.
 P302+P352 – If on skin: wash with plenty of soap and water.
 P305+P351+P338 – If in eyes: rinse cautiously with water for several minutes. Remove contact lenses, if
present and easy to do. Continue rinsing.
 P301+P330+P331 – If swallowed or ingested: Rinse mouth. Do NOT induce vomiting.
 P333+P313 – If skin irritation occurs: get medical advice/attention.
 P337+P313 – If eye irritation persists: get medical advice/attention.

90-SDS-SV-ADENO Page 1 of 4 Rev. -


Effective Date: 08/2016
SAFETY DATA SHEET
SURE-VUE® ADENO TEST KIT

SECTION III: COMPOSITION


Chemical Composition:
Strip contains reagents in dry form (Nitrocellulose membrane, fiberglass pad, antibodies and colloidal gold
solution). Pursuant to OSHA’s Hazardous Communications Standard 29 CFR 1910.1200, these products are not
considered to contain hazardous materials.
Tubes with Extraction Buffer: Buffer contains 0.1% Sodium Azide.
Chemical Name CAS No. % Classification
Sodium Azide 26628-22-8 0.1 H303 + H313

SECTION IV: FIRST AID MEASURES


After skin contact: Immediately, wash affected area thoroughly with soap and water. Remove contaminated
clothing and shoes, if necessary. Seek medical attention, if irritation develops or persists.
After eye contact: Immediately, flush eyes under gently running water for at least 15 minutes, making sure that
the eyelids are held open. Seek medical attention, if irritation or redness develops.
After ingestion: Rinse mouth with plenty of water to dilute the substance. Immediate medical attention is
required.
After inhalation: Move person into fresh air. Seek medical attention.

SECTION V: FIRE FIGHTING MEASURES


Extinguishing Media: Not combustible. Use extinguishing media suitable for surrounding materials.
Special Fire and Explosion Hazards: May react with lead and copper plumbing to form explosive metal azides.
Drains should be flushed thoroughly with water after disposing of buffer to prevent azide buildup.
Hazardous Combustion Products: None
Protective Equipment for Firefighters: Wear self-contained breathing apparatus and full protective gear.

SECTION VI: ACCIDENTAL RELEASE MEASURES


Personal Precautions: Avoid skin and eye contact by wearing appropriate lab personal protective equipment
(PPE)
Environmental Precautions: Absorb into inert solid or dilute with a large quantity of water and flush into an
approved wastewater treatment system. Use good laboratory practices.

SECTION VII: HANDLING AND STORAGE


Handling Precautions: Use good laboratory practices.
Recommended Storage Conditions: Store at 15- 30 C to maintain efficacy.
Other Precautions/Special Hazards: Avoid eye and skin contact.

90-SDS-SV-ADENO Page 2 of 4 Rev. -


Effective Date: 08/2016
SAFETY DATA SHEET
SURE-VUE® ADENO TEST KIT

SECTION VIII: EXPOSURE CONTROLS AND PERSONAL PROTECTION


Exposure Limits: US OSHA: None established. ACGIH: None established.
DFG MAK: None established. Engineering Controls: Use in well ventilated area.
Eye Protection: Safety glasses should be worn to prevent eye contact.
Skin Protection: Impervious gloves should be worn to prevent skin contact.

SECTION IX: PHYSICAL AND CHEMICAL PROPERTIES

Form: Test strip reagents in dry form; extraction buffer is a liquid. Auto-ignition Temperature: N/A
Color: Test strip is white; extraction buffer is clear, colorless. Flash Point: N/A
Odor: Not identified. Decomposition Temperature: N/A
Boiling Point/Boiling Range: N/A Viscosity: N/A
Flash Point: N/A

SECTION X: STABILITY AND REACTIVITY


Stability: Stable under normal temperatures and pressures.
Hazardous Incompatibilities: N/A
Hazardous Decomposition: Not available.

SECTION XI: TOXICOLOGICAL INFORMATION

Toxicity Data for Hazardous Ingredients: N/A


Primary Routes of Exposure: Skin or eye contact.
Potential Effects of Acute Exposure: Low order of acute toxicity.
Potential Effects of Chronic Exposure: None identified
Symptoms of Overexposure: No specific symptoms identified
Carcinogenicity: No ingredients in this product are listed as carcinogens by ACGIH, IARC, NTP, OSHA or
67/548/EEC Annex I.
Other Effects: None Identified

SECTION XII: ECOLOGICAL INFORMATION


Ecotoxicity: No results of ecological studies are available.
Biodegradability: No results of biodegradability studies are available.
Mobility: No results of mobility studies are available.

90-SDS-SV-ADENO Page 3 of 4 Rev. -


Effective Date: 08/2016
SAFETY DATA SHEET
SURE-VUE® ADENO TEST KIT

SECTION XIII: DISPOSAL CONSIDERATIONS


Waste Disposal: Disposal practice must be in compliance with company, local, state and federal laws and
regulations. If needed, Contact local, state or country environmental agency for specific rules.
Recommended Product Disposal: Sodium Azide may react with lead and copper plumbing to form explosive
metal azides. Drains should be flushed thoroughly with water after disposing of buffer to prevent azide buildup.

SECTION XIV: TRANSPORT INFORMATION


Transportation is not regulated under ICAO, IATA, US DOT, Canadian TDG or European ADR/RVD.

SECTION XV: REGULATORY INFORMATION


Product is not classified as a dangerous preparation according to 1999/45/EC and 200/58/EC. Under US Federal
and State Regulations.

SECTION XVI: OTHER INFORMATION

Employers should use this information as a supplement to other information gathered by them and should make
independent judgment of the suitability of this information to ensure proper use and to protect the health and
safety of employees. This information is provided without warranty and any use of this product not in
conformance with this Safety Data Sheet, or in combination with any other product or process is the responsibility
of the user. SA Scientific, Inc. shall not be held liable for any damage resulting from the handling or use of this
product.

90-SDS-SV-ADENO Page 4 of 4 Rev. -


Effective Date: 08/2016