Connector Service Manual
Rev C
Copyright 2007-2011
Contents
1. 2. 3. 4. 5. 6. Connector Introduction Service Tools Working with d-sub connectors Working with crimp connectors Working with power connectors Working with coax connectors
Copyright 2007-2011
Connector Introduction
The Vertical Power system uses two types of connectors. Power connectors
Can handle up to 18 amps of current per pin and are used to provide power to lights, avionics, contactors, etc. These are used on the Control Unit. Each CU has an 8, 10, 12, and 16 pin connector minimizing the risk of a mis-match.
D-sub (d-subminiature) connectors
For use with low-current circuits such as data signals, position sensor feedback, micro-switches, and trim motors. These are used on the Control Unit and Display Unit. Each d-sub connector is unique to minimize the risk of a mis-match.
Copyright 2007-2011
Terminals
Power Connector Sockets D-sub Pins & Sockets
Orientation Feature
Machined-Barrel Pin
Machined-Barrel Socket (not used)
Crimp Pin (not used)
Crimp Socket (not used)
Copyright 2007-2011
Types of Crimp Connectors
Butt Connectors Spade Connectors Ring Connectors
Note: All connectors shown are mil-spec
Copyright 2007-2011
D-sub Connector Service Tools
Crimping Tool
The machined-barrel sockets on the d-sub connectors should be crimped with a tool like this one. It applies even pressure around the barrel.
Pin Removal Tool
Standard d-sub tool is red/white. High density d-sub tool is green/white.
Copyright 2007-2011
Wire Strippers
(for homebuilder use) Not Recommended! Better Best
Copyright 2007-2011
Insulated Terminal Crimp Tools
(for homebuilder use) Not Recommended! Better Best
Single crimp
Copyright 2007-2011
Double crimp
8
Power Connector Service Tools
Crimping Tool The sockets on the power connectors must be crimped with the correct crimping tool. Vertical Power provides a variety of wiring harnesses and extra wires with crimped terminals installed to eliminate the need for this tool. If you choose to build your own harness or need this tool for any reason, Vertical Power rents and sells this tool. Terminal Removal Tool The terminals are released using this tool. Small screwdriver 2mm or 3mm head
Copyright 2007-2011
Reading Wire Markings
Mil-spec wire is marked along its length
Mil-spec 22759/16
M 2 2 7 5 9 / 1 6 1 8 2 7 4 7 8
Copyright 2007-2011
18 gauge wire
10
Wire Specifications
Mil-W-22759/16 Single Conductor, Non-Shielded
Wire gauge 24 22 20 18 16 14 12 10 8 6 4 2 1/0 2/0
Max diameter (in) .047 .054 .062 .073 .081 .095 .117 .142 .202 .253 .318 .392 .485 .553
Weight per foot (lbs) .00257 .00368 .00536 .00789 .00995 .0149 .0226 .0351 .0635 .0999 .157 .239 .391 .504
Pull Test (lbs)
15 19 38 50 70 110 150
Copyright 2007-2011
11
Working with d-sub Connectors
Copyright 2007-2011
12
D-sub Connector Numbering
Note that numbering is reversed for male and female connectors. 15 pin connectors show for example.
15
15
Copyright 2007-2011
13
Step 1: Mark the pin numbers on both sides of the d-sub with a Sharpie Step 2: Strip the end of the wire
D-sub Terminal Install
Step 3: Install terminal into crimper tool, ensuring crimp tool is adjusted to the proper height. The head of the terminal should be flush with the top of the tool. Step 4: Crimp terminal to wire. Step 5: Insert terminal into connector assembly until you hear a slight click. Give the wire a tug to make sure it is fully seated. Visually inspect the other face of the connector to verify proper placement of the terminal.
Copyright 2007-2011
14
D-sub Pin Removal
Step 1: Insert white side of removal tool into connector. Carefully wrap metal prongs around the wire.
White end (wrong side pictured)
Step 2: Push down on tool until you feel it seat around the terminal. Note: you may have to fish around for a bit until it seats properly.
Step 3: Gently pull the wire and the tool together out of the connector.
Also see: http://aeroelectric.com/articles/D-Sub_Pin/Pin-Extraction.html
Copyright 2007-2011
15
Working with Crimp Connectors
Copyright 2007-2011
16
Anatomy of a Good Crimp Connector
Nylon insulation, usually translucent (vinyl is opaque - dont use). Brazed seam Tang to stop wire Window to examine wire end Wire gauge marked on connector
High-quality connectors have the wire gauge stamped on the metal, and the insulation is translucent (nylon)
Copyright 2007-2011
17
Crimping, Part 1
1. 2. Strip wire. Insert connector into the proper location on the crimp tool. 12-10ga 16-14ga 22-18ga
3.
Place the open end on the side with the colored dots. Adjust the location so the opposite side is just outside the crimp tool. Press just enough to hold the terminal while inserting the wire. Crimp until it bottoms out. A ratcheting crimper ensures you have crimped the connector properly.
Copyright 2007-2011
18
Crimping, Part 2
4. Remove terminal from crimper and Inspect form proper crimp.
5. Tug on the wire. 6. Tug on the wire again. 7. Insulate with heat shrink tubing if desired. Wire visible at end
Insulation is crimped
Wire is crimped
Copyright 2007-2011
19
Vibration
Even with the best crimp, vibration can cause wires to fail near the connector. Reducing the negative effects of vibration can increase the life of the connection.
D-sub connectors
Wires can vibrate within the connector housing
Orange or black silicon tape can reduce vibration
Crimp connectors
Wires can vibrate near the connector
Heat shrink can reduce vibration
Copyright 2007-2011
20
Working with Power Connectors
Copyright 2007-2011
21
Power Connector Crimping Terminals - 1
Step 1: Ensure the crimping tool is properly set up. The back of the tool should be configured with the white side up to accept female terminals. If the black, or male, side is up, lift on the center knob and rotate the assembly (with the crimper open) to the correct position. A ratchet mechanism ensures the crimper is fully engaged. If you need release the crimper while it is locked, press the release as shown.
Correct
Incorrect
Latch release
Copyright 2007-2011
22
Power Connector Crimping Terminals - 2
Step 2: Insert the terminal into the proper location on the crimper as indicated by the AWG (wire gauge) size. Terminals provided by Vertical Power should go into the 18-22 crimp location (even 14 gauge wire).
Terminal inserted in crimper here
Dont use this side for tefzel wire
Copyright 2007-2011
23
Power Connector Crimping Terminals - 3
Step 3: Once the terminal is inserted, push down on the small lever on the back of the crimper. This acts as a backstop for the wire so that it does not go too far into the terminal.
Copyright 2007-2011
24
Power Connector Crimping Terminals - 4
Step 4: Strip the correct amount of insulation from the wire. The exposed wire should be just long enough to fit in the crimp area. Step 5: Insert wire into terminal in crimper so that wire butts up against lever on back. Hold wire against bottom of terminal so that crimp can go all the way around the wire. You may want to practice on a few wires to get the hang of it.
Crimps over insulation
Crimps over wire
Ensure wire is inside entire length of crimp, with little or no excess hanging out the end.
Copyright 2007-2011
25
Power Connector Installing Terminals - 1
Step 1: Insert a small screwdriver (max width= 3.0 mm) into either pry point Step 2: Using the housing as a pivot point gently pry out on the white insert, until it reaches pre-lock position (5.0 mm travel)
Before
After
The white insert should never be removed! If it is removed, discard the entire connector. Do not attempt to re-assemble.
Copyright 2007-2011
26
Power Connector Installing Terminals - 2
Step 3: With the white insert still in the out position, align the terminal to rear of connector. Align the orientation feature as shown and insert through appropriate opening. If resistance is encountered, retract the terminal and adjust the angle of insertion. Continue inserting the terminal until it stops with an audible click. Give the wire a slight tug to make sure it is seated properly. It should not come back out.
90 mis-orientation Not a straight entry
Orientation feature aligned with index
Copyright 2007-2011
27
Power Connector Installing Terminals 2a
Troubleshooting: The terminal should insert smoothly into the connector housing. If it does not, the following are the most likely causes: 1. The terminal is rotating while you are inserting it. The terminal must remain aligned until it is fully inserted.
2.
The tangs on the insulation crimp may not be fully closed. Gently squeeze the tangs closed around the insulation with a pair of pliers.
3.
The white insert may have closed. Open the insert.
Copyright 2007-2011
28
Power Connector Installing Terminals - 3
Step 4: With the terminals fully installed, the white insert can be seated into its final lock position by applying an even force to both ends until it comes to a stop, with an audible click. The white insert should move a distance of 5.0 mm (about ).
Push evenly until you hear a click
Locked
Copyright 2007-2011
29
Power Connector Removing Terminals - 1
Step 1: Insert a small screwdriver (max width= 3.0 mm) into either pry point Step 2: Using the housing as a pivot point gently pry out on the white insert, until it reaches pre-lock position (5.0 mm travel)
Before
After
The white insert should never be removed! If it is removed, discard the entire connector. Do not attempt to re-assemble.
Copyright 2007-2011
30
Power Connector Removing Terminals - 2
Step 3: Using the pin removal tool, insert the tip into the terminal service hole adjacent to the terminal to be serviced. Step 4: Push down gently to release locking finger. You will hear a gently click. Do not apply any lateral force, as this may damage the connector or the terminal! Step 5: With the white insert still in the out position, gently pull on the wire to release the terminal. If the terminal resists, the service tool may not be fully engaged. Remove the tool and re-try. Push the service tool further into the service opening to ensure that it has fully disengaged the locking finger.
Do not insert the tool into the terminal opening! Do not use excessive force, excessive force can damage the connector!
Not Here Insert Here
Copyright 2007-2011
31
Power Connector Removing Terminals - 3
Step 6: The white insert can be seated into its final lock position by applying an even force to both ends until it comes to a stop, with an audible click. The white insert should move a distance of 5.0 mm (about ).
Push evenly until you hear a click
Locked
Copyright 2007-2011
32
Proper Crimping
Copyright 2007-2011
33
Working with Coax Connectors
Copyright 2007-2011
34
Coax
Here are links to sites which have good directions for coax connectors:
http://www.terminaltown.com/Pages/Page2.html http://www.extron.com/download/files/userman/cabtermkit-man.pdf http://www.aeroelectric.com/articles/bnccrimp.pdf
Good all-around connector info:
http://aeroelectric.com/articles/Getting_Started.pdf
Copyright 2007-2011
35