Fixed Displacement
zp11
zp12
Conversion
factors
1 kg ............................................................... 2.20 lb 1 N .............................................................. 0.225 lbf 1 Nm ........................................................ 0.738 lbf ft 1 bar ............................................................. 14.5 psi 1 l .................................................... 0.264 US gallon 1 cm 3 ....................................................... 0.061 cu in 1 mm ........................................................... 0.039 in 9/ C + 32 .......................................................... 1 F 5
Catalogue HY17-8249/US
Content Content
General information ................................................ 4 F11 cross section ................................................... 4 F12 cross sections ................................................. 5 Specifications ......................................................... 6 Ordering codes F11-CETOP ............................................................ 7 F11-ISO .................................................................. 8 F11-SAE ................................................................. 9 F12-ISO ................................................................ 10 F12-Cartridge ....................................................... 11 F12-SAE ............................................................... 12 Prefered versions F11/F12 ................................... 13 Technical information Bearing life ........................................................... 14 Bearing life calculation .......................................... 14 Required information ............................................ 14 Noise level ............................................................ 15 Efficiency .............................................................. 15 Selfpriming speed and required inlet pressure ..... 16 Installation dimensions F11-5 CETOP ....................................................... 17 F11-10 CETOP ..................................................... 18 F11-14 CETOP ..................................................... 19 F11-19 CETOP ..................................................... 20 F11-14 ISO ........................................................... 21 F11-14 SAE .......................................................... 22 F11-19 SAE .......................................................... 23 F12-30, -40, -60, -80 and -110 ISO ................ 24-25 F12-30, -40, -60, -80 and -110 Cartridge ........ 26-27 F12-30, -40, -60, -80 and -110 4 bolt flange .... 28-29 F12-30, -40, and -60 2 bolt flange ................... 30-31 F11-150 CETOP ................................................... 32 F11-150 SAE ........................................................ 33 F11-250 SAE ........................................................ 34 Technical information F11 saw motors .................................................... 35 F11 fan motors ..................................................... 35 F12 integrated flushing valve ................................ 36 F12 accessory valve blocks .................................. 36 Type BT brake valve ............................................. 37 Type SR pressure relief/make-up valve ................ 37 Type SV pressure relief valve ............................... 38 Speed sensor ....................................................... 38 F12 main port suction fittings ............................... 39 Suction fittings ...................................................... 39 Suction fitting kits ................................................. 39 Split-flange kits ..................................................... 39 Installation information ......................................... 40 Direction of rotation .............................................. 40 Hydraulic fluids ..................................................... 40 Operating temperature ......................................... 40 Installation information Viscosity ............................................................... 41 Filtration ............................................................... 41 Case pressure ...................................................... 41 Case drain connections ........................................ 42 Before start-up ..................................................... 42 3
Parker Hannifin Mobile Controls Division Trollhttan, Sweden
Catalogue HY17-8249/US
General information
F11 and F12 are bent axis, fixed displacement heavyduty motor/pump series. They can be used in numerous applications in both open and closed loop circuits. Series F11 is available in the following frame sizes and versions: - F11-5, -10, -14, 19 and -150 with CETOP mounting flange and shaft end - F11-14 with ISO flange and shaft - F11-14, -19, -150 and -250 with SAE flange and shaft Series F12 conforms to current ISO and SAE mounting flange and shaft end configurations. A very compact cartridge version is also available. Thanks to the unique spherical piston design, F11/F12 motors can be used at unusually high shaft speeds. Operating pressures to 480 bar provides for the high output power capability. The 40 angle between shaft and cylinder barrel allows for a very compact, lightweight motor/pump.
10
Catalogue HY17-8249/US
Legend:
1. 2. 3. 4.
Barrel housing Valve plate Cylinder barrel Piston with piston ring
5. 6. 7. 8.
F12-110
10
11
5
Parker Hannifin Mobile Controls Division Trollhttan, Sweden
Catalogue HY17-8249/US
Specifications
Frame size F11-5 Displacement [cm3/rev] [cu in/rev] Operating pressure max intermittent1) [bar] [psi] max continuous [bar] [psi] 4.9 0.30 420 6 000 350 5 000 -10 9.8 0.60 -14 14.3 0.87
480 420 420 7 000 6 000 6 000 420 350 350 6000 5 000 5 000
Motor operating speed [rpm] max intermittent1) 12 000 11 000 10 000 9 000 7 100 6 400 5 600 5 200 4 700 3 000 2 700 max continuous 10 800 9 900 9 000 8 100 5 600 5 000 4 300 4 000 3 600 2 600 2 400 min continuous 50 50 Max pump selfpriming speed2) L or R function; max [rpm] 4 600 4 200 Motor input flow max intermittent1) [l/min] [gpm] max continuous [l/min] [gpm] Main circuit temp.3), max [C] [F] min [C] [F] Mass moment of inertia (x10-3) [kg m2] (x10-2) [lbft2] Weight [kg] [lb] 58 15.3 52 13.7 80 175 -35 -31 0.16 0.38 5 11 108 28.5 97 25.6 3 900 143 37.8 128 33.8 3 500 171 45.2 153 40.4 3150 2870 2500 2300 2290 213 56.3 168 44.4 256 67.6 200 52.8 1 700 1 500
335 418 517 450 650 88.5 110.4 136.6 119.0 172.8 257 322 396 390 580 67.9 85.1 104.6 103.0 153.6 80 175 -35 -31
-35 -31
-35 -31
2.9 5 8.4 11.2 40 46 6.88 11.86 19.93 26.58 94.92 109.16 16.5 36 21 46 26 57 36 79 70 154 77 170
1) Intermittent: max 6 seconds in any one minute. 2) Selfpriming speed valid at sea level. 3) See also installation information, operating temperature.
1000 x v
Torque (M) M =
D x p x hm [Nm] 63
Power (P) P =
q x p x t [kW] 600
Catalogue HY17-8249/US
Ordering codes
F11
Pump Motor
Frame size
Shaft
Version number
Option page 36
Option page 38
F11-CETOP
Frame size Code Displacem. (cm3/rev) 5 4.9 10 9.8 14 14.3 19 19.0 150 150.0
Option None 5 x x (x) (x) (x) x x 10 x x (x) (x) (x) x x 14 x x x 19 150 x x (x) (x) (x) x x x x (x) (x) (x) x x
Frame size Code Function M Motor H Motor, high pressure Q Motor, silent J Motor, clockwise rot'n 1) G Motor, counter clockw.1) R Pump, clockwise rot'n L Pump, counter clockw.
Frame size 5 10 14 19 150 Code Shaft K Metric key x x x x x D Spline, DIN 5480 (x) (x) (x) (x) (x)
Frame size Code Main ports B BSP threads R With anti-cavitation valve; clockwise rotn2) L With anti-cavitation valve; counter clockw.2) U SAE, UN threads F SAE 6000 psi flange
5 x (x) -
10 x x x (x) -
14 x x x -
19 150 x x x (x) x
Frame size Code Shaft seal N NBR3), low pressure H NBR3), high pressure E FPM4), low pressure, high temperature V FPM4), high pressure, high temperature
5 x x x -
10 x x x x
14 x x
19 150 x x x x x x x -
Frame size Code Mounting flange C CETOP flange W Saw motor flange
5 x -
10 x x
14 x x
19 150 x x x -
Frame size Code Option S With speed sensor P Prepared for speed sensor
5 -
10 -
14 x x
19 150 x x -
x: 1) 2) 3) 4)
Available (x): Optional Internal drain BSP threads NBR - Nitrile rubber FPM - Fluor rubber
: Not available
Catalogue HY17-8249/US
Ordering codes
F11
Pump Motor
Frame size
Shaft
Version number
Option page 36
Option page 38
F11-ISO
Frame size Code Displacem. (cm3/rev) 14 14.3
Frame size Code Function H Motor, high pressure R Pump, clockwise rot'n L Pump, counter clockw.
14 x x x
Frame size 14 Code Shaft K Metric key x D Spline, DIN 5480 (x)
Option None
14 x
Frame size Code Shaft seal E FPM1), low pressure, high temperature V FPM1), high pressure, high temperature
14
x x
14 x
Frame size Code Option S With speed sensor P Prepared for speed sensor
14 x x
: Not available
Catalogue HY17-8249/US
Ordering codes
F11
Pump Motor
Frame size
Shaft
Version number
Option page 36
Option page 38
F11-SAE
Frame size Code Displacem. (cm3/rev) 14 14.3 19 19.0 150 150.0 250 242.0 Version number (assigned for special versions)
Option None Frame size Code Function M Motor H Motor, high pressure Q Motor, silent J Motor, clockwise rot'n 1) G Motor, counter clockw.1) R Pump clockwise rot'n L Pump counter clockw. 14 x x x 19 150 250 x x (x) (x) (x) x x x x (x) (x) (x) x x x x x
Frame size 14 19 150 250 Code Shaft T SAE key x x x S SAE spline (x) (x) (x) (x) K Metric key x F SAE spline (x)
Frame size Code Main ports U SAE, UN threads B BSP threads F SAE 6000 psi flange2) R With anti-cavitation valve; clockwise rotn3) L With anti-cavitation valve; counter clockw.3)
14 x x x
Frame size Code Shaft seal N NBR4), low pressure H NBR4), high pressure E FPM5), low pressure, high temperature V FPM5), high pressure, high temperature
14 x x
19 150 250 x x x x x x x x x x -
14 x
19 150 250 x x x
Frame size Code Option S With speed sensor P Prepared for speed sensor
14 x x
19 150 250 x x -
x: 1) 2) 3) 4) 5)
Available (x): Optional Internal drain Metric thread BSP threads NBR - Nitrile rubber FPM - Fluor rubber
: Not available
Catalogue HY17-8249/US
Ordering codes
F12
Frame size
Shaft
Version number
Option page 36
Option page 38
F12-ISO
Frame size Code Displacem. (cm3/rev) 30 30.0 40 40.0 60 59.8 80 80.4 110 110.1 Version number (assigned for special versions)
30 40 60 x x x x x x x x x
30 x
40 x
60 x
80 110 x -3)
30 40 60 x x x
80 110 x x
Frame size Code Option S With speed sensor P Prepared for speed sensor
30 x x
40 x x
60 x x
80 110 x x x x
Frame size Code Shaft seal H NBR 1), high pressure N NBR 1), low pressure V FPM2), high temperature, high pressure
30 x x x
40 x x x
60 x x x
80 110 x x x x x x
x : Available (x) : Optional : Not available 1) NBR - Nitrile rubber 2) FPM - Fluor rubber 3) F12-110: Accessory valve block (page 36)
10
Catalogue HY17-8249/US
Ordering codes
F12
Frame size
Shaft
Version number
Option page 36
Option page 38
F12-Cartridge
Frame size Code Displacem. (cm3/rev) 30 30.0 40 40.0 60 59.8 80 80.4 110 110.1 Version number (assigned for special versions)
Frame size 30 40 60 80 110 Code Shaft C DIN spline Standard x x x x x K Metric key Standard x x x X " " Optional - (x) - -
30 40 60 x x x
80 110 x x
30 x
40 x
60 x
80 110 x -3)
30 40 60 x x x
80 110 x x
Frame size Code Option S With speed sensor P Prepared for speed sensor
30 x x
40 x x
60 x x
80 110 x x x x
Frame size 30 Code Shaft seal H NBR1), high pressure x N NBR1), low pressure x V FPM2) high temperature, x high pressure)
40 x x x
60 x x x
80 110 x x x x x x
x : Available (x) : Optional : Not available 1) NBR - Nitrile rubber 2) FPM - Fluor rubber 3) F12-110: Accessory valve block (page 36)
11
Catalogue HY17-8249/US
Ordering codes
F12
Frame size
Shaft
Version number
Option page 36
Option page 38
F12-SAE
Frame size Code Displacem. (cm3/rev) 30 30.0 40 40.0 60 59.8 80 80.4 110 110.1 Version number (assigned for special versions)
Frame size Code Shaft S SAE spline Standard U " " Optional T SAE key Standard 80 110 x x x x x x
30 x x
40 x x
60 x x
80 110 x (x) x x x
30 40 60 x x x x x x x x x
30 x
40 x
60 x
80 110 x -3)
Frame size 30 40 60 80 110 Code Main ports S SAE flange x x x x x U SAE, UN threads (x) (x) (x) - (x)
Frame size Code Option S With speed sensor P Prepared for speed sensor
30 x x
40 x x
60 x x
80 110 x x x x
Frame size 30 40 60 80 110 Code Mounting flange S SAE 4 bolt x x x x x T SAE 2 bolt x x x - -
Frame size Code Shaft seal H NBR1), high pressure N NBR1), low pressure V FPM2), high temperature, high pressure
30 x x x
40 x x x
60 x x x
80 110 x x x x x x
x : Available (x) : Optional : Not available 1) NBR - Nitrile rubber 2) FPM - Fluor rubber 3) F12-110: Accessory valve block (page 36)
12
Catalogue HY17-8249/US
Part number 3799843 3799844 3799851 3799616 3799525 3799526 3799532 3799533 3799617 3799988 3799989 3799998 3799618 3780767 3780772 3780783 3781530 3781534 3781542
13
Catalogue HY17-8249/US
Bearing life calculation An application is usually governed by a certain duty or work cycle where pressure and speed vary with time during the cycle. In addition, bearing life depends on external shaft forces, fluid viscosity in the case and fluid contamination. Parker Hannifin (Mobile Controls Division) has a computer program for calculating bearing life and will assist in determining F11 or F12 motor/pump life in a specific application. Required information When requesting a bearing life calculation from Parker Hannifin (Mobile Controls Division), the following information (where applicable) should be provided: - A short presentation of the application - F11 or F12 size and version - Duty cycle (pressure and speed versus time at given displacements) - Low system pressure - Case fluid viscosity - Life probability (B10, B20, etc.) - Operating mode (pump or motor) - Direction of rotation (L or R) - External shaft loads - Fixed or rotating radial load - Distance between flange and radial load - Angle of attack () as defined below
Bearing fatigue
System pressure
The direction (a) of the radial load is positive in the direction of rotation as shown. To obtain maximum bearing life, the radial load should, in most cases, be located approximately at 170 (motor; R.H. rot'n) or 190 (pump; R.H rot'n).
14
Catalogue HY17-8249/US
F12-30 (motor)
Volumetric efficiency.
100% 90% 80% 0 1000 2000 3000 4000 3000 psi
6000 psi
F12-30 (motor)
Speed [rpm]
Mechanical efficiency.
Noise level
Series F11/F12 feature low noise levels from low to high speeds and pressures. As an example, the diagram to the right shows the noise level of an F12-30. The noise level is measured in a semi-anechoic room, 1 m behind the unit. The noise level for a particular motor/pump may vary 2 dB(A) compared to what is shown in the diagram. NOTE: Noise information for F11/F12 frame sizes are available from Parker Hannifin.
1000
2000
3000
4000
15
Catalogue HY17-8249/US
Series F11 30 In pump applications, the F11 with function L (counter H F11-19 clockwise rotation) or R (clockwise rotation) is normally used. The L and R (pump) provide the highest self20 priming speeds (see table) as well as the lowest noise M level. The M (motor) function can also be used as a 15 pump, in either direction, but at a lower selfpriming speed. 10 Operating above the selfpriming speed (refer to Diagram 1) requires increased inlet pressure. L, R As an example, at least 1.0 bar is needed when operat0 ing the F11-19-M as a pump at 3500 rpm. An F11 with 5 in. Hg vacuum H function, used as a motor (e.g. in a hydrostatic transmission), may sometimes operate as a pump at 1000 2000 3000 4000 Speed [rpm] speeds above the selfpriming speed; this requires Diagram 1. Min required inlet pressure (F11-19). additional inlet pressure. Insufficient inlet pressure can cause pump cavitation resulting in greatly increased pump noise and deterioInlet press. rating performance.
[psi] F12-110 -80 -60 -40 -30 30
F12-L or -R
10
Series F12 When operating the F12 as a pump (with L or R valve plate) above the selfpriming speed, the inlet must be pressurized. Increased noise and deteriorating performance may otherwise be experienced. Diagrams 2 and 3 show required pump inlet pressure vs. shaft speed. The F12 motor (type M valve plate) sometimes operates as a pump e.g. when used in a propel transmission and the vehicle is going downhill. Minimum required inlet pressure versus shaft speed is shown in the diagrams.
5 in. Hg vacuum
1000
2000
3000
F12-M
20
10
5 in. Hg vacuum
Catalogue HY17-8249/US
3.31 max 1.50 Main port A BSP " Main port B BSP "
2.56 0.20 1.87 Approx. center of gravity Drain port D BSP "
0.98 4.47
0.31
R 0.03
0.47 min
Key 6x6
17
Catalogue HY17-8249/US
3.70 max 1.81 Main port A BSP " Main port B BSP "
3.11 0.43 2.09 Approx. center of gravity Drain port D BSP "
1.18 5.24
0.31
R 0.03
0.47 min
Key 6x6
18
Catalogue HY17-8249/US
Main port B (BSP 3/4-A) 4.02 2.83 1.26 2.09 1.77 Speed sensor (optional) Drain port D (BSP 3/8-A) 1.18 25
5.87 3.94
0.55 0.31 0.37 R 0.02 1.65 1.38 Flange C Type K key shaft R 0.03 Key 8x7x35 1.02 M8x0.63 1.10 3.9370 3.9349 0.14 0.31 0.9846 0.9841 1.06 0.9744 W 25x1.25x18x9g Type D spline shaft (DIN 5480)
19
B
CCW CW
39 (x4) 4.49
A
5.51 5.91 Type C mounting flange
Parker Hannifin Mobile Controls Division Trollhttan, Sweden
Catalogue HY17-8249/US
4.49 max Main port A BSP " 2.13 Main port B BSP "
3.46
1.14 5.43
Flange C 0.91 Key shaft K 0.63 min M8* 0.9846 0.9841 Key 8x7x35 0.98 1.65 R 0.04 max R 0.05 max 0.39
1.10
* Metric thread 0.98
6.69 max
1.10 5.51
20
Catalogue HY17-8249/US
3.98 1.81
4.02
2.09 1.77 Speed sensor (optional) Drain port M26 (metric thread; depth 0.47; ISO 9974-1) 5.47 3.54
1.18 4.84 Drain port M26 (metric thread; depth 0.47; ISO 9974-1) 0.47
25 5.79 (max)
0.26 0.73 R 0.02 max M8 (metric thread) 0.63 deep 1.10 3.1496/3.1478
Type K key shaft 1.65 1.38 Key 8x7x35 0.14 0.31 0.9846/0.9841 1.06 0.35 (x4)
21
B A
CCW
CW
Catalogue HY17-8249/US
3.98 1.81
4.02
2.09 1.77
1.18 6.21 (max) Drain port 9/16" UNF, O-ring boss; SAE J514d 5.24 0.67 (x2) 0.37 0.31 R 0.02
5/16"-24 UNF-2B
25
1.50
1.25
(0.31) 1.30 0.95 Type S spline shaft 13 T, 16/32 DP (SAE J498b; class 1, 30 involute spline, flat root, side fit)
1.000/0.998
R 10.24 (x2)
CCW
CW
B
4.72
0.57 (x2)
A
5.75
22
Catalogue HY17-8249/US
3.46
7.13 max
R 0.03 R 0.04 Key shaft T SAE 'B-B' (SAE J744c) 1.000 0.998 1.11 min
0.31 R 0.55 1.02 0.57 (x2) 1.30 SAE 'B' (13T, 16/32 DP; class 1, flat root, side fit) Spline shaft S (SAE J498b) 5.75 * O/ring boss (SAE J514d) ** UNC thread 30 4.84 Mounting flange S SAE 'B' (SAE J744c)
6.93 max
23
Catalogue HY17-8249/US
A2 C2
B2
Port D
K3
G2 G3
Port C1)
N2
L3 H3 R2
K2
H2 (0.02) J2
J3 D3 (thread) E3 F3
Q2
C1 A1 T3
D1 (x4)
Shown: F12-80
24
Catalogue HY17-8249/US
Installation dimensions
Dim. A1 B1 C1 D1 A2 B2 C2 D2 E2 F2 G2 H2 J21) J22) K2 L2 M2 N2 P2 Q2 R23) R24) S2*3) F12-30 3.48 4.65 4.65 0.43 3.94 2.32 0.98 F12-40 F12-60 4.46 5.75 5.59 0.53 4.33 2.56 1.02 4.46 5.75 5.67 0.53 4.92 2.76 0.87 F12-80 5.01 6.22 6.10 0.53 5.32 3.05 1.26 F12-110 5.57 7.09 7.09 0.71 5.71 3.35 1.50 0.55 2.26 6.2992/ 6.2967 9.09 1.59 3.23 2.61 2.76 0.24 7.05 0.32 1.61 1.97 M16 x36 6.69 3.29 1.250 M16 1.7724/ 1.7717 1.91 7.05 1.52 1.42 2.626 0.87 2.68
0.32 0.32 0.39 0.47 1.30 1.65 1.65 2.05 3.9370/ 4.9213/ 4.9213/ 5.5118/ 3.9349 4.9188 4.9188 5.5093 6.77 1.00 1.97 1.97 2.16 1.58 0.20 5.37 0.32 1.10 1.38 1.69 M12 x24 4.80 2.60 0.937 6.81 1.28 2.36 2.05 1.97 0.20 5.39 0.32 1.10 1.38 1.38 M12 x24 5.28 2.60 0.937 7.48 1.28 2.36 2.13 1.97 0.20 6.06 0.32 1.30 1.61 M12 x28 5.67 2.60 0.937 8.50 1.28 2.76 2.76 2.21 0.28 6.79 0.32 1.42 1.77 1.61 M16 x36 6.10 2.95 1.094
A, B: ISO 6162
Metric key shaft (in mm) Type K (standard) F12-30 -40 -60 -80 -110 30 dia. 30 dia. 35 dia. 40 dia. 45 dia. Type P (optional) 25 dia. -
A3 B3 C3 D3* E3 F3 G3 H3 J3 K3 L3 S3 T3
M12 M12 M12 M16 1.1817/ 1.1817/ 1.3787/ 1.5755/ 1.1812 1.1812 1.3780 1.5749 1.30 1.30 1.50 1.69 5.37 0.93 0.95 2.000 0.71 0.63 5.39 1.20 0.95 2.000 0.79 0.63 6.06 1.20 1.10 2.000 0.79 0.63 6.79 1.20 1.42 2.250 0.79 1.02 -
* Metric thread
1) Key shaft type K 2) " " " P 3) Spline shaft type D 4) " " " Z.
25
Catalogue HY17-8249/US
A5 C5
B5
Port D
R6 H6
O-ring (included)
T5
P5
J5
M6 N6 P6
D5
T6 C4
A4 Port E (third drain port) F12-110 barrel housing (ISO/cartridge version) 40 (-30, -40, -60, -110) 43 (-80) XX D4 (x2) E4
Shown: F12-80
B4
26
Catalogue HY17-8249/US
Installation dimensions
Dim. A4 B4 C4 D4 E4 A5 B5 C5 F12-30 F12-40 F12-60 F12-80 F12-110 6.30 5.51 7.40 0.55 3.03 3.94 2.32 0.98 7.87 6.46 9.25 0.71 3.74 4.33 2.56 1.02
1) 2)
0.39 0.47 0.55 D5 0.31 E5 1.1817/ 1) 2) 1.3787/ 1.5755/ 1.7724/ 1.1812 1.3780 1.5749 1.7717 F5 5.3150/ 6.2992/ 6.2992/ 7.4803/ 7.8740/ 5.3125 6.2967 6.2967 7.4775 7.8712 G5 H5 J5 K5 L5 M5 N5 P5 Q5 R5 S5 T5 V5 A6 B6 C6 G6 H6 K6 L6 M6 N6 P6 Q6 R6 T6 5.00 3.50 1.97 0.55 1.57 0.20 3.58 0.87 1.10 1.38 2.78 0.59 1.30 4.80 2.60 0.937 3.60 2.74 2.000 0.63 3.62 4.33 5.047 0.20 0.20 5.24 3.63 2.36 0.63 1.97 0.20 3.82 1.18 1.10 1.38 2.83 0.59 1.38 5.28 2.60 0.937 3.82 2.80 2.000 0.71 4.53 5.00 6.031 0.20 0.20 5.75 3.63 2.36 0.59 1.97 0.20 4.33 1.22 1.10 1.38 2.99 0.59 1.38 5.67 2.60 0.937 4.33 2.91 2.000 0.71 4.53 5.31 6.031 0.20 0.20 6.18 4.35 2.76 0.59 2.20 0.28 4.49 1.57 1.46 1.77 3.58 0.59 1.77 6.10 2.95 1.094 4.49 3.52 2.250 0.79 5.12 6.06 7.213 0.20 0.20 6.89 4.83 0.59 4.84 1.57 1.46 1.77 3.77 0.59 1.77 6.69 3.27 1.250 4.84 3.69 2.626 0.79 5.51 6.30 7.606 0.20 0.20 2.68
A, B: ISO 6162
Spline shaft (DIN 5480; in mm) Type C (standard) F12-30 -40 -60 -80 -110 W30x2x14x9g W30x2x14x9g W30x2x14x9g W40x2x18x9g W40x2x18x9g
Metric key shaft (in mm) Type K (std) Type X (opt.) F12-30 -40 -60 -80 -110 30 dia. 35 dia. 40 dia. 35 dia.
O-ring dimensions (in mm) F12-30 -40 -60 -80 -110 127x4 150x4 150x4 180x4 190x4
1) Key shaft type K: D5 - 0.31; E5 - 1.1817/1.1812 2) Key shaft type X: D5 - 0.39; E5 - 1.3787/1.3780
27
Catalogue HY17-8249/US
G8 G9
H9
J9
See table
M8
T9 A7
C7
A7 B7
D7 (x4)
28
Catalogue HY17-8249/US
Installation dimensions
Dim. A7 B7 C7 D7 A8 B8 C8 D8 E8 F8 G8 H8 J8 K8 L8 M8 N8 Q81) Q82) R81) R82) A9 B9 C9 D9* E9 F9 G9 H9 J9 K9 L9 T9 F12-30 3.54 4.65 4.65 0.55 3.94 2.32 0.98 0.25 1.30 4.000/ 3.998 7.46 0.31 1.50 2.83 1.25 0.10 6.04 0.91 1.30 4.80 2.60 0.937
5/ 16"-24
F12-40 4.51 5.83 5.67 0.55 4.33 2.56 1.02 0.31 1.65 5.000/ 4.998 7.76 0.31 1.89 2.99 1.50 0.16 6.34 0.91 1.89 5.28 2.60 0.937
3/ 8"-24
F12-60 4.51 5.83 5.67 0.55 4.92 2.76 0.87 0.31 1.65 5.000/ 4.998 8.43 0.31 1.89 3.11 1.50 0.16 7.02 0.91 1.89 5.67 2.60 0.937
3/ 8"-24
Ports F12-30 F12-40 F12-60 F12-80 F12-110 A, B size Screw thread 3) C thread D thread E thread
3/ 3/ 7/ 3/ 4" 3/ 3/ 7/ 3/ 4" 3/ 3/ 7/ 7/ 4" 7/
6.36 8.03 7.87 0.83 5.71 3.35 1.50 0.44 2.26 6.000/ 5.998 10.39 0.31 2.64 3.90 2.13 0.29 8.35 1.34 2.63 6.69 3.27 1.250
5/ 8"-18
1"
16"-14 8"-14 8"-14
11/4"
1/ 2"-13 (0.98)
(0.87)
(0.79)
(0.87)
(1.06)
7/ 7/
Mounting flange (SAE J744) S (standard) F12-30 -40 -60 -80 -110 SAE 'B', 4 bolt SAE 'C', " SAE 'C', " SAE 'C', SAE 'D', " " X (optional) SAE D, 4 bolt -
Spline shaft (SAE J498b, class 1, flat root, side fit) S (standard) U (opt.) X (optional) F12-30 -40 -60 -80 -110 SAE 'B' 13T, 16/32 DP SAE 'C' 14T, 12/24 DP SAE 'C' 14T, 12/24 DP SAE 'C-C' 17T, 12/24 DP SAE 'D' 13T, 8/16 DP -
Key shaft (SAE J744) T (standard) F12-30 -40 -60 -80 -110 SAE 'B-B' (1"/ 25.4 mm) SAE 'C' (11/4"/ 31.75 mm) SAE 'C' (11/4"/ 31.75 mm) SAE 'C-C' (11/2"/ 38.1 mm) SAE 'D' (13/4"/ 44.45 mm)
Main ports A and B, type U (optional) F12-110 1 5/8" - 12 UN O-ring ports according to SAE J514d
29
Catalogue HY17-8249/US
A12 B12 C12 Port A Port B K12 G11 Port C (inspection/ drain port) Flushing valve (optional) A11 C11 Port D B11
G12
N11
L11
J11
M11
A10 B10
30
Catalogue HY17-8249/US
Installation dimensions
Dim. A10 B10 C10 D10 E10 F10 A11 B11 C11 D11 E11 F11 G11 H11 J11 K11 L11 M11 N11 Q11 R11 A12 B12 C12 D12 * E12 F12 G12 H12 J12 K12 L12 F12-30 5.75 6.93 2.48 0.57 0.39 0.39 3.94 2.32 0.98 0.25 1.30 4.000/ 3.998 7.46 0.31 1.50 2.80 1.25 0.10 6.06 1.02 1.30 4.80 2.60 0.937
5/ 16"-24
F12-40 7.13 8.46 2.91 0.69 0.63 0.61 4.33 2.56 1.02 0.31 1.65 5.000/ 4.998 7.76 0.31 1.89 3.03 1.50 0.16 6.34 1.06 1.89 5.28 2.60 0.937
3/ 8"-24
F12-30
3/ 3/ 3/ 3/ 4"
F12-40
3/ 3/ 3/ 3/ 4"
F12-60
3/ 3/ 7/ 7/ 4"
A, B (main ports): SAE J518c (6000 psi) C, D (drain ports): O-ring boss (SAE J514) 1) UN thread (depth in inches).
Main ports A and B, type U (optional) F12-30 1 1/16" - 12 UN -40 1 5/16" - 12 UN -60 1 5/16" - 12 UN O-ring ports according to SAE J514d = Max 350 bar operating pressure.
Mounting flange (SAE J744) Type T F12-30 -40 -60 SAE 'B', 2 bolt SAE 'C', 2 bolt SAE 'C', 2 bolt
Spline shaft(SAE J498b, class 1, flat root, side fit) Type S F12-30 -40 -60 SAE 'B' 13 T; 16/32 DP SAE 'C' 14 T; 12/24 DP SAE 'C' 14 T; 12/24 DP
* UNF-2B thread Key shaft (SAE J744) Type T F12-30 -40 -60 1" dia. SAE 'B-B' 11/4" dia. SAE 'C' 11/4" dia. SAE 'C'
31
Catalogue HY17-8249/US
6.77
6.26 0.98
1.81 1.97 10 3.23 1.18 1.9692/ 1.9686 M16 (metric thread) 2.11
9.84 1.97
0.87(x4)
1.18 1.97
9.29
9.29 max
Type C mounting flange
32
Catalogue HY17-8249/US
8.74 max 3.98 1.437 Main port A 1 1/2" ** Main port B 1 1/2" ** M16* (x8) 6.77 4.65 0.71 Approx. center of gravity Drain port D BSP 3/4" 3.13 3.35 11.69 Drain port C BSP 3/4" 13.98 8.11 0.50 6.18 0.31 0.94
2.63
R 0.03
R 0.04 Flange S 2.24 min 6.000/ 5.998 7/ "x7/ "x21/ " 16 16 8 (key)
1.18
1.94
1.750/ 1.748
7.56
6.362
2.63
SAE 'D'; 13T, 8/16 DP; class 1, flat root, side fit Spline shaft S (SAE J498b)
33
Catalogue HY17-8249/US
M16 (x8) 1.4 deep (metric thread) Main port B 1 1/2" * 3.125
7.76 1.06
4.65
5.55
15.55
13.23
7.09 0.31
8.50 0.94
3.23
R 0.03
0.31 SAE F; 15T, 8/16 DP; class 1, flat root, side fit Optional: SAE S; 13T, 8/16 DP Spline shaft F (SAE J498b) 6.36 8.11 max Mounting flange S SAE 'D' (SAE J744c) 0.83 (x4) * 6000 psi flange (SAE J581c)
1.38 2.63
34
Catalogue HY17-8249/US
Protective cover
Saw bar
Main port B
Port G
Drain port C
35
Catalogue HY17-8249/US
Nozzle (optional)
Port B
36
Catalogue HY17-8249/US
Brake release valve flushing valve etc. Port BR (brake release) Port A
F12motor
Port B
37
Catalogue HY17-8249/US
(Port L) Port A
Speed sensor
A speed sensor kit is available for series F11/F12. A ferrostat differential (Hall-effect) sensor installs in a separate, threaded hole in the F11/F12 bearing housing. On F12 the speed sensor is directed towards the ring gear.On F11 the speed sensor is directed towards the pistons. The speed sensor outputs a square wave signal within a fequency range of 5 Hz to 20 kHz. NOTE: - The motor bearing housing must be prepared for the speed pick-up; refer to the F11/F12 ordering codes (pages 7-12). - On F11 the pistons position must be known before mounting. - Additional information is provided in Mobile motor/pump accessories (catalogue HY17-8258/UK). - The speed sensor is also shown in the illustrations on pages 19, 21, 22, 24, 26 and 28.
Speed sensor
Speed sensor
Catalogue HY17-8249/US
Suction fitting
(Split-flange half)
(Mounting screw)
L [inch] 3.94
(O-ring) 2" hose
1" 11/4"
3.94 4.02
L
The suction fittings are designed for use with standard SAE or metric split-flange halves as shown. O-ring and mounting screw sizes are listed below. SAE size
3/ " 4
1" 1/ " 1 4
Suction fitting kits Suction fitting kits are available for the F12 ISO and Cartridge versions. A kit consists of a suction fitting (shown above), two split-flange halves, an O-ring and four mounting screws. Part no. 379 4421 370 4098 370 3926 SAE size
3/ " 4
1" 1/ " 1 4
Split-flange kits Separate metric split-flange kits, consisting of two splitflange halves and four mounting screws for use on the F12 ISO and cartridge versions, are also available. Part no. 379 4405 370 4329 370 4330 SAE size
3/ " 4
(Split-flange half)
(Mounting screw)
1" 11/4"
39
Catalogue HY17-8249/US
Installation information
Direction of rotation The M and H versions of series F11, and the M version of series F12, are bi-directional. The L and R pump versions are uni-directional, allowing higher selfpriming speeds (refer to page 14). The illustration to the right shows direction of flow versus shaft rotation. In a motor application, the shaft turns clockwise when port B (black arrow) is pressurized, and counter clockwise when port A (open arrow) is pressurized. In a pump application where the shaft turns clock-wise, port B is the inlet port and should be connected to tank; when the shaft turns counter clockwise, port A is the inlet port. Hydraulic fluids Ratings and performance data for series F11/F12 are based on operating with good quality, contaminationfree, petroleum-based fluids. Hydraulic fluids type HLP (DIN 51524), automatic transmission fluids type A, or API CD engine oils can be used. Fire resistant fluids (when used under modified operating conditions) and synthetic fluids may also be suitable. For additional information, refer to Hydraulic Marketing IS data base: - Hydraulic fluid specifications - Fire resistant fluids. Operating temperature The following temperatures should not be exceeded (type H and N shaft seals): Drain fluid: 195 F (90 C) Viton shaft seals (F11 type E, F12 type V) can be used to 240 F (115 C) drain fluid temperature. NOTE: The temperature should be measured at the utilized drain port. Continuous operation may require case flushing in order to meet the viscosity and temperature limitations. The following table shows operating speeds, above which flushing is usually required, as well as suggested flow through the case.
Clockwise rotation
NOTE: When operating the F11/F12 as a pump above the selfpriming speed (valid for both the pump and motor versions), the inlet must be sufficiently pressurized. Increased noise and deteriorating performance may otherwise be experienced. For further information refer to Selfpriming speed and required inlet pressure on page 6.
Series F11
Frame size F11-5 F11-10 F11-14 F11-19 F11-150 F11-250 Speed [rpm] Flow [l/min] Flow [gpm] 5500 12 0.25-0.5 4500 23 0.5-0.8 4500 23 0.5-0.8 4000 24 0.5-1.0 2200 1020 2.6-5.2 1800 1222 3.2-5.8
Series F12
Frame size F12-30 F12-40 F12-60 F12-80 F12-110 Speed [rpm] Flow [l/min] Flow [gpm] 3500 48 1.02.1 3000 510 1.32.6 3000 714 1.93.7 2500 816 2.14.2 2300 918 2.44.8
40
Catalogue HY17-8249/US
Installation information
Viscosity The ideal operating range is75 to 150 SUS (15 to 30 mm2/s). At operating temperature, the viscosity (of the drain fluid) should be kept above 46 SUS (8 mm2/s [cSt]). At start-up, the viscosity should not exceed 5 000 SUS (1000 mm2/s) Filtration To obtain the highest service life of the F11/F12, the fluid cleanliness should meet or exceed ISO code 18/13 (ISO 4406). During normal operating conditions, a 10 m (absolute) filter is recommended. Case pressure The tables below show the highest recommended case pressure as a function of shaft speed. Nominal shaft seal life can be expected at a certain speed and the corresponding max case pressure. Seal life will be shorter, however, at unfavourable operating conditions (high temperature, low oil viscosity, contaminated oil). Series F11 Speed Shaft seal F11-5 F11-10 F11-14 F11-19 F11-150 F11-250
Max case pressure [psi] versus shaft speed [rpm] 1500 3000 4000 5000 6000 8000 9000 10000 11000 12000 H/V N/E H/V N/E H/V N/E H/V N/E H/V N/E H/V N/E H/V N/E H/V N/E H/V N/E H/V N/E 20 20 19 19
2.2 13 1.9 2.2 11.5 1.8 2.2 9.5 1.5 2.2 9.5 1.4
4.5 0.6 4.5 -
10 8.5 7 7
8 7 5.5 5.5
5 4 3.5 3.5
3 -
0 -
Max recommended case pressure versus shaft speed - F11 seal types H or V and N or E.
Series F12 Speed Shaft seal F12-30 F12-40 F12-60 F12-80 F12-110 Max case pressure [psi] vs. shaft speed [rpm] 1500 3000 4000 5000 6000 H/V N H/V N H/V N H/V N H/V N 205 30 175 30 175 30 145 30 140 30 100 20 85 15 85 15 70 10 65 10 80 15 65 10 65 10 60 65 10 50 5 50 5 50 -
5 -
Max recommended case pressure versus shaft speed F12 seal types H or V, and N
41
Catalogue HY17-8249/US
Installation information
Case drain connections Series F11/F12 have two drain ports, C and D, while F12-110 has an additional port, E. The uppermost drain port (such as port C in the illustration below) should always be utilized.
Drain flow Port C Port E (F12-110)
In mounting positions such as 'shaft up' (below) a spring loaded check valve should be installed in the drain line in order to insure a sufficiently high oil level in the case. Preferably, the drain line should be connected directly to the reservoir.
Before start-up Make sure the F11/F12 case as well as the entire hydraulic system is filled with a recommended fluid. The internal leakage, especially at low operating pressures, is not sufficient to provide lubrication at start-up.
NOTE:
To avoid cavitation and obtain a low noise level as well as reduced heat generation, tubes, hoses and fittings must be adequately dimensioned. Preferably, the suction line flow speed should be 1.5 to 3.5 fps (0.5 to 1 m/s), and pressure line flow speeds 10 to 16 fps (3 to 5 m/s). For series F12, suitable suction fittings are available (refer to page 39).
42
Catalogue HY17-8249/US
General information
! WARNING
FAILURE OR IMPROPER SELECTION OR IMPROPER USE OF THE PRODUCTS AND/OR SYSTEMS DESCRIBED HEREIN OR RELATED ITEMS CAN CAUSE DEATH, PERSONAL INJURY AND PROPERTY DAMAGE. This document and other information from Parker Hannifin Corporation, its subsidiaries and authorized distributors provide product and/or system options for further investigation by users having technical expertise. It is important that you analyze all aspects of your application, including consequences of any failure, and review the information concerning the product or system in the current product catalogue. Due to the variety of operating conditions and applications for these products or systems, the user, through its own analysis and testing, is solely responsible for making the final selection of the products and systems and assuring that all performance, safety and warning requirements of the application are met. The products described herein, including without limitation, product features, specifications, designs, availability and pricing, are subject to change by Parker Hannifin Corporation and its subsidiaries at any time without notice.
Offer of Sale
Please contact your Parker representation for a detailed Offer of Sale.
43
Latin America
Pan American Division
7400 N.W. 19th Street Suite A Miami, FL 33126 USA Tel: +305 470 8800 Fax: +305 470 8808
Mexico
Via de Ferrocarril a Matamoros #730 Apodaca, N.L. Mexico C.P. 6 6 6 0 0 Tel: +52 81 56 6000 Fax: +52 81 56 6076
Argentina
Stephenson 2711 (1667) TortuguitasMalvinas Argentinas Pcia. de Buenos Aires Argentina Tel: +54 11 4752 4129 Fax: +54 11 4752 3704
Brazil
Av. Lucas Nogueira Garcez 2181 Jacarei, SP Brazil 12300-000 Brazil Tel: +55 12 354 5100 Fax: +55 12 354 5262
Chile
Av. Americo Vespucio 2760-C, Conchali Santiago Chile Tel: +56 2 623 1216 Fax: +56 2 623 1421
Venezuela
Av. Principal de Boleita Norte con Calle Miraima, Edf. Draza, Planta Baja Caracas 1070 Venezuela Tel: +58 212 238-5422 Fax: +58 212 239-2272
Parker Hannifin is the worlds premier supplier of motion and control systems and solutions, with sales and manufacturing facilities throughout the world. For product information and details of your nearest Parker sales office, visit us at www.parker.com or call free on 1-800-272-7537 (North America).
Catalogue HY17-8249/US 2M 03/04 RT Copyright 2004 Parker Hannifin Corporation All rights reserved.