Instruction Manual
This manual contains important safety information and must be carefully read in its entirety and understood prior to installation by all personnel who install, operate and/or maintain this product.
GENERAL PROVISIONS Quincy Compressor (The Seller) warrants to each retail purchaser (Purchaser) products of the Sellers own manufacture against defects in material and workmanship. With respect to products not manufactured by the Seller, the Seller will, if practical, pass along the warranty of the original manufacturer. The Sellers sole obligation under this warranty shall be, at its option, to repair, replace, or refund the purchase price of any product or part thereof which is deemed to be defective, provided the Purchaser meets all of the applicable requirements of this warranty and none of the limitations apply. WARRANTY PERIODS Basic Compressors Seller warrants for twelve (12) months from date of startup or twenty-four (24) months from factory shipment, whichever occurs rst. This includes labor and approved travel. All warranty travel expense will be paid to the nearest authorized repair center. Remanufactured Basics Seller warrants for six (6) months from date of start-up or eighteen (18) months from date of factory shipment, whichever occurs rst. This includes labor and approved travel. All warranty travel expense will be paid to the nearest authorized repair center. Replacement Parts Seller warrants repaired or replaced parts of its own manufacture against defects in material and workmanship under normal use and service for ninety (90) days, or for the remainder of the warranty on the product being repaired, whichever is longer. Parts purchased outside the compressors warranty period are warranted for ninety (90) days from the date of distributor sale, or one (1) year from the date of shipment from the factory, whichever occurs rst. Normal maintenance items and procedures are not warranted unless found to be defective in material or workmanship, i.e. but not limited to lters, gaskets, rings, valves and control lines.
LIMITATIONS Notice of the alleged defect must be given to the Seller in writing with all identifying details, including serial number, model number, type of equipment and date of purchase within thirty (30) days of discovery of same during the warranty period. If requested by Seller, such product or product thereof must be promptly returned to Seller, freight collect for inspection. The Seller must have the warranty registration card on le at Quincy, IL. within ten (10) days of start-up or the warranty may be declared null and void. The above warranties shall not apply and Seller shall not be responsible nor liable for: (a) Consequential, collateral or special losses or damages. (b) Equipment conditions caused by fair wear and tear, abnormal conditions, accident, neglect or misuse of equipment, improper storage or damages resulting during shipment. (c) Deviation from operating instructions, specications or other terms of sales. (d) Labor charges, loss or damage resulting from improper operation, maintenance or repairs made by person(s) other than Seller or Sellers authorized service station. (e) Improper application or installation of product. (f) Warranty travel expense is not covered on QT-5 & PLT-5 compressors sold as basics. DISCLAIMER In no event shall Seller be liable for any claims, whether arising from breach of contract or warranty or claims of negligence or negligent manufacture, in excess of the purchase price. This warranty is the sole warranty of Seller and any other warranties, express, implied in law or implied in fact, including any warranties of merchantability and tness for particular use, are hereby specically excluded.
Quincy Compressor
WARRANTY PERIODS
Quincy Compressor (Seller) warrants original basic compressors (see Standard Warranty for replacement basic compressors) on factory assembled PRO, MAX and Xtreme units for ve (5) years from date of start-up, provided Purchaser registers the product with Quincy Compressor and maintains the unit with Quincy genuine parts and lubricant. Rings and gaskets are covered for the entire ve (5) year period. Suction and discharge valves are covered for two (2) years. The True Blue warranty covers approved parts, labor and travel per the schedule below: One (1) year: Parts, Labor, and Travel Two (2) years: Parts, Labor, and Travel Three (3) years: Approved Parts and Labor Four (4) years: Approved Parts and Labor Five (5) years: Approved Parts and Labor - 100% - 100% - 100% - 100% - 100%
LIMITATIONS
Notice of any alleged defect must be given to the Seller in writing, with all identifying details (including serial number, model number, type of equipment and date of purchase), within thirty (30) days of discovery, during the warranty period. If requested by the Seller, the defective product or portion thereof must be promptly returned to Seller for inspection. The Seller must have the Purchasers warranty registration on le at Quincy, Illinois within ten (10) days of start-up, or this warranty may be declared null and void. The above warranties shall not apply to and Seller shall not be liable for: a. Equipment conditions caused by normal wear and tear, abnormal conditions, accident, neglect or misuse of equipment, improper storage or damages resulting during shipment; D e v i a t i o n f ro m o p e r a t i n g i n s t r u c t i o n s , specications or other terms of sales; Labor charges, loss or damage resulting from improper operation, maintenance or repairs made by person(s) other than Seller or Sellers authorized service station; or Improper application or installation of product.
b. c.
The complete PRO, MAX or Xtreme unit is warranted for two (2) years from date of start-up and includes labor, parts and approved travel. Normal maintenance items, such as belts, lters, check valves and tank drains, are not warranted unless found to be defective in material or workmanship.
d.
DISCLAIMER
THIS WARRANTY IS THE SOLE WARRANTY OF THE SELLER AND ANY AND ALL OTHER WARRANTIES, EXPRESS OR IMPLIED, INCLUDING ANY WARRANTIES OF MERCHANTABILITY AND FITNESS FOR PARTICULAR PURPOSE, ARE HEREBY SPECIFICALLY EXCLUDED. THE SELLERS LIABILITY FOR ANY LOSS OR DAMAGE ARISING OUT OF OR RESULTING FROM OR IN ANY WAY CONNECTED WITH THE PRODUCTS SHALL NOT EXCEED PURCHASERS PURCHASE PRICE FOR THE PARTICULAR PRODUCT UPON WHICH SUCH LIABILITY IS BASED, REGARDLESS OF WHETHER SUCH LIABILITY ARISES IN CONTRACT (INCLUDING, BUT NOT LIMITED TO, FAILURE OR DELAY IN PERFORMANCE OR DELIVERY DUE TO ANY CAUSE WHATSOEVER), TORT (INCLUDING, BUT NOT LIMITED TO, NEGLIGENCE OR STRICT LIABILITY) OR OTHERWISE. IN NO EVENT SHALL THE SELLER BE LIABLE FOR LOSS OF PROFITS OR REVENUE OR FOR ANY INCIDENTAL, CONSEQUENTIAL, INDIRECT, SPECIAL OR PUNITIVE DAMAGES.
GENERAL PROVISIONS
Seller warrants, to each retail Purchaser, products of the Sellers own manufacture, against defects in material and workmanship under normal use and service. With respect to products not manufactured by the Seller, the Seller will, if reasonably practical, pass along the warranty of the original manufacturer. The Sellers sole obligation under this warranty shall be, at its option, to repair, replace or refund the purchase price of any product or part thereof which is deemed by the Seller to be defective, provided the Purchaser meets all of the applicable requirements of this warranty and none of the limitations apply. Requirements: 1. Purchaser must register product with Seller via www.quincycompressor.com or the registration card provided. 2. Purchaser must maintain the compressor with genuine Quincy Compressor parts and lubricants for entire warranty period (proof of purchase required).
Quincy Compressor
Contents
SECTION 1 SAFETY
Safety First ............................................................................................................................................. 1 Summary of Changes .............................................................................................................................. 3
SECTION 2
SYSTEM DYNAMICS
Description & Application ...................................................................................................................... 4 Principles of Compression Cycles .......................................................................................................... 4 Principles of Lubrication Systems ......................................................................................................... 4 Principles of Cooling Systems ................................................................................................................ 4 Principles of Dryers & Filters ................................................................................................................ 5
SECTION 3
Receiving Delivery .................................................................................................................................. 6 Freight Damage ...................................................................................................................................... 6 Location ................................................................................................................................................... 7 Electrical Supply Requirements ............................................................................................................. 8 Wiring & Piping Schematics .................................................................................................................. 9 Mounting ............................................................................................................................................... 18 System Components ............................................................................................................................. 18 Induction System .................................................................................................................................. 20 Compressed Air Discharge System ...................................................................................................... 20
SECTION 4
Pre-Starting Checklist .......................................................................................................................... 24 Initial Starting & Operating ................................................................................................................. 25 Daily Starting Checklist ....................................................................................................................... 26
SECTION 5
Stopping for Maintenance ..................................................................................................................... 27 Maintenance Schedule .......................................................................................................................... 27 Maintenance Schedule Checklist Sample ............................................................................................ 27 Lubrication ............................................................................................................................................ 29 Pulley / Sheave Alignment & Belt Tension ......................................................................................... 30 Pressure Switch Adjustment ................................................................................................................ 31 Torquing Cylinder to Head Capscrews ................................................................................................. 32 Pilot Valve Adjustment Instructions .................................................................................................... 33
SECTION 6 SECTION 7
Troubleshooting .................................................................................................................................... 34
SECTION 1
Safety First
SAFETY
At Quincy Compressor safety is not only a primary concern, but a faithfully performed practice. Beginning with the design stage, safety is built into The Worlds Finest Compressor. It is the intention of this manual to pass along the safety first concept to you by providing safety precautions throughout its pages. DANGER !, WARNING !, and CAUTION ! are displayed in large bold capital letters in the left hand column to call attention to areas of vital concern. They represent different degrees of hazard seriousness, as stated below. The safety precaution is spelled out in bold upper and lower case letters in the right hand column. Immediate hazards which will result in severe personal injury or death. Hazards or unsafe practices that could result in personal injury or death. Hazards or unsafe practices which could result in minor personal injury, product or property damage. Each section of this instruction manual, as well as any instructions supplied by manufacturers of supporting equipment, should be read and understood prior to starting the compressor. If there are any questions regarding any part of the instructions, please call your local Quincy distributor, or the Quincy Compressor factory before creating a potentially hazardous situation. Life, limb, or equipment could be saved with a simple phone call. Compressors are precision high speed mechanical equipment requiring caution in operation to minimize hazard to property and personnel. There are many obvious safety rules that must be observed in the operation of this type of equipment. Listed below are some additional safety precautions that must be observed. Transfer of toxic, dangerous, flammable or explosive substances using Quincy Compressor products is at the users risk. Turn off and lockout/tagout (per OSHA regulation 1910.147) the main power disconnect switch before attempting to work or perform any maintenance. Do not attempt to service any part of the unit while it is operating. Per OSHA regulation 1910.147, relieve the system of all pressure before attempting to service any part of the unit. Allow ample time for the compressor to cool before performing service procedures. Some surface temperatures exceed 350F when the compressor is operating.
Do not operate the unit with any of its safety guards, shields, screens, enclosure panels or doors removed. Do not remove or paint over any DANGER!, WARNING!, CAUTION!, or instructional materials attached to the compressor. Lack of information regarding hazardous conditions can cause property damage or personal injury. Periodically check all pressure relief valves for proper operation. Do not change the pressure setting of the pressure relief valve, restrict the function of the pressure relief valve, or replace the pressure relief valve with a plug. Do not install a shutoff valve in the compressor discharge line without first installing a pressure relief valve of proper size and design between the shutoff valve and the compressor. Do not use plastic pipe, rubber hose, or lead-tin soldered joints in any part of the compressed air system. Alterations must not be made to this compressor without Quincy Compressors approval. Be sure that all tools, shipping and installation debris have been removed from the compressor and installation site prior to starting the compressor. Do not operate the compressor in excess of the ASME pressure vessel rating for the receiver or the service rating of the compressor, whichever is lower. Make a general overall inspection of the unit daily and correct any unsafe situations. All fasteners must be kept tight. Reckless behaviour of any kind involving compressed air is dangerous and can cause very serious injury to the participants. Provisions should be made to have the instruction manual readily available to the operator and maintenance personnel. If for any reason any part of the manual becomes illegible or the manual is lost, have it replaced immediately. The instruction manual should be read periodically to refresh ones memory. It may prevent a serious or fatal accident. Never use a flammable or toxic solvent for cleaning the air filter or any parts. Air used for breathing or food processing must meet OSHA 29 CFR 1910.134 or FDA 21 CFR 178.3570 regulations. Failure to do so may cause severe injury or death. Oil and moisture residue must be drained from the air receiver daily or after each use. Accumulations of oil residue in the receiver can be ignited by embers of carbon created by the heat of compression, causing an explosion, damage to property and injury to personnel.
DANGER ! WARNING !
QT & PLT Series 50161-106, January 2009
The owner, lessor or operator of any compressor unit manufactured by Quincy Compressor is hereby warned that failure to observe the safety precautions and procedures outlined in this manual may result in serious personal injury, damage to property, and may void your warranty. Quincy Compressor must authorize all warranty service. Before contacting your distributor or the factory, check the maintenance requirements and the troubleshooting guide for your compressor. Most warranty issues can be resolved by following proper maintenance procedures. Quincy Compressor neither states as fact, nor in any way implies that the above list of safety precautions is an all inclusive list, the observance of which will prevent all damage to property or injury to personnel. Every effort has been taken to ensure that complete and correct instructions have been included in this manual. However, possible product updates and changes may have occurred since this printing. Quincy Compressor reserves the right to change specifications without incurring any obligation for equipment previously or subsequently sold.
SECTION 2
Description & Application
SYSTEM DYNAMICS
Quincy Compressor QT Series and PLT Series compressors are heavy duty, air cooled, belt driven compressors. QT Series two stage compressors are splash lubricated and capable of delivering 175 PSIG of compressed air. The PLT Series compressors are pressure lubricated and capable of delivering 175 PSIG of compressed air.
enclosure, across the motor, compressor and intercooler. These compressors are designed to be operated with the compressor sheave turning in a counterclockwise rotation (as viewed tummy to the sheave). QT, PLT and Xtreme compressors should be operated in temperatures under 104F.
SECTION 3
Receiving Delivery
INSTALLATION
Immediately upon receipt of compressor equipment and prior to completely uncrating, the following steps should be taken: Step 1) Inspect compressor equipment for damage that may have occurred during shipment. If any damage is found, demand an inspection from the carrier. Ask the carrier how to file a claim for shipping damages. (Refer to SECTION 3, Freight Damage for complete details.) Shipping damage is not covered by Quincy Compressor warranty. Insure that adequate lifting equipment is available for moving the compressor equipment.
Step 2)
WARNING !
Improper lifting can result in component or system damage, or personal injury. Follow good shop practices and safety procedures when moving the unit. Step 3) Read the compressor nameplate to verify the model and size ordered. Read the motor nameplate to be sure the motor is compatible with your electrical conditions (volts, phase, hertz). Read the pressure relief valve nameplate to be sure it does not exceed the working pressure shown on the compressor or any other component in the system. Read and understand the safety precautions contained within this manual. The successful and efficient operation of compressor equipment depends largely upon the amount of care taken to install and maintain the equipment. Quincy Compressor strongly recommends that any or all person(s) in charge of installing, maintaining, or servicing one of our compressors read and understand the entire contents of this manual in order to perform such duties safely and efficiently.
Step 4)
Step 5)
Step 6)
Freight Damage
It is extremely important that you examine every carton and crate as soon as you receive it. If there is any obvious damage to the shipping container, have the delivering carrier sign the freight bill, noting the apparent damage, and request a damage report. If concealed damage is discovered at a later date, the carrier must be notified within 15 days of initial receipt of freight. Concealed shipping damage is not covered by Quincy Compressor Warranty. Contact the carrier as soon as possible, giving them an opportunity to inspect the shipment at the premises where the delivery was made. Do not move the damaged freight from the premises where the original delivery was made.
QT & PLT Series 50161-106, January 2009 6 Quincy Compressor 3501 Wismann Lane, Quincy Ill. - 62305-3116
Retain all containers and packing for inspection by the carrier. A claim form can be requested from the carrier: Standard Form for Presentation of Loss and Damage Claims (form # 3208). Your claim will need to be substantiated with the following documents: a.) b.) c.) d.) e.) form #3208 original bill of lading original paid freight bill original invoice or certified copy other particulars obtainable in proof of loss or damage (photos, damage inspection, etc.)
The proper description and classification of our product in the National Motor Freight Classification 100-H, contained in item 118100, reads as follows: Compressors, air, or air ends: with or without air tanks, hose or nozzles, mounted or not mounted. We suggest that these instructions be circulated to your shipping and receiving personnel.
Location
QT & PLT Series air compressors should be installed in an area that is clean, dry, well lighted, adequately ventilated, and not less than 24 inches to a wall or other compressor. (Note: A gas engine will produce carbon monoxide; always provide adequate ventilation!) Inspection and maintenance checks are required daily. Therefore, sufficient space needs to be provided around the compressor for safe and proper inspection, cleaning, and maintenance. Ample circulation of air must be provided across the compressor cylinders, heads and cooler (if so equipped). If at all possible, the pulley drive system (i.e. motor pulley, compressor sheave, belts and guard) should be located next to a wall to minimize any danger created by the drive system while the compressor is operating. Do not allow hot air from additional equipment to blow towards the compressor. QT & PLT series compressors should be operated in temperatures under 104F. In cold climates, the compressor should be installed in a heated building.
CAUTION ! WARNING !
Do not operate this compressor in ambient temperatures lower than -15 F. A crankcase heater is recommended for a compressor that is to operate in temperatures under 32 F. Under no circumstances should a compressor be used in an area that may be exposed to toxic, volatile, or corrosive atmosphere. Do not store toxic, volatile, or corrosive agents near the compressor. Noise Noise is a potential health hazard that must be considered. There are federal and local laws governing acceptable noise levels. Check with local officials for specifications.
Excessive noise can be effectively reduced through various methods. Total enclosures, intake silencers, baffle walls, relocating or isolating the compressor can reduce noise levels. Care must be taken when constructing total enclosures or baffle walls. If not properly constructed or positioned, they could contribute to unacceptable noise levels or overheating. Consult your local Quincy distributor if assistance is required.
WARNING !
Unusual noise or vibration indicates a problem. Do not operate the compressor until the source has been identified and corrected.
High voltage may cause personal injury or death. Disconnect and lockout/tagout per OSHA regulation 1910.147 all electrical power supplies before opening the electrical enclosure or servicing. Never assume a compressor is safe to work on just because it is not operating. It could restart at any time. Follow all safety precautions outlined in SECTION 5, Stopping For Maintenance. Electrical enclosures and components must be in compliance with NEMA environmental ratings for the areas in which they are being installed.
Magnetic Starter
Connect incoming power lines at screw terminals L1, L2 & L3. Contactor
Overload Relay
Quincy Compressor
Fig. 3-1 3 Phase Magnetic Motor Starter With Automatic Start / Stop Control Wiring Schematic WP1744A (Rev. D) See Fig.s 3-5 & 3-6 for Xtreme (Cabinet Units) Wiring Schematics
Magnetic Starter
10
Overload Relay
Quincy Compressor
Fig. 3-2 Single Phase Magnetic Motor Starter With Automatic Start / Stop Control Wiring Schematic WP1744B (Rev. D) See Pages 13 & 14 for Xtreme (Cabinet Units) Wiring Schematics
Pressure Switch Connect incoming power line at this screw terminal. Install incoming power line connections at screw terminals L1 & L2.
11
Fig. 3-3 Single Phase 5 hp-230V Economy Units Automatic Start / Stop Control- Pressure Switch Wired to Motor Wiring Schematic WP1753 (Rev. H) See Fig.s 3-5 & 3-6 for Xtreme (Cabinet Units) Wiring Schematics
Splice incoming power line connection to this white wire (wrapped in red tape).
Quincy Compressor
Pressure Switch
12
Fig. 3-4 Single Phase Combination Pressure Switch / Overload Relay Wired to Motor Connection Diagram See Fig.s 3-5 & 3-6 for Xtreme (Cabinet Units) Wiring Schematics
Quincy Compressor
Contactor
Overload Relay
Magnetic Starter
Fig. 3-5 3 Phase Magnetic Motor Starter With Automatic Start / Stop Control Wiring Schematic WP1744A8 (Rev. A) For Xtreme Cabinet Units
Contactor
Overload Relay
Magnetic Starter
Fig. 3-6 Single Phase Magnetic Motor Starter With Automatic Start / Stop Control Wiring Schematic WP1744B7 (Rev. A) For Xtreme Cabinet Units
Fig. 3-8 Continuous Run - Load / Unload Control Piping Schematic WP1781C
Fig. 3-9 Dual Control with Pilot Valve Unloading Piping Schematic WP1781A
Mounting
Proper mounting of QT & PLT series compressor units is crucial to the safe operation and longevity of the equipment. The installation requires a flat and level concrete floor or pad (for mobile units see Mounting FLANGE NUT Mobile Units). Satisfactory results can usually be obLeave loose & lock tained by mounting the compressor unit on vibration with a back-up nut RECEIVER FOOT isolating pads available from your local Quincy distributor. All vertical tank units must be anchored! Refer to ISOLATOR BACKING PLATE OR SHIMS IF Fig. 3-7, Isolator Installation for Unanchored or NECESSARY Anchored Receiver. ISOLATOR State or local codes may mandate that the compressor be bolted to the floor. In this case the unit must be leveled and bolted making absolutely certain the feet are not stressed in any manner. Leave the flange nut loose & lock it with a back-up nut! Uneven feet drawn tightly to the concrete pad will cause severe vibrations resulting in cracked welds or fatigue failure. The customer is responsible for providing a suitable foundation & isolator mounting where necessary.
UNANCHORED
ANCHORED 110365
Mounting Mobile Units Gas engine driven compressors mounted to truck beds should be fastened in such a way so as not to create any stress to the air receiver tank. Truck beds, characteristically, have a tendency to flex and could cause damage to the receiver tank if the tank is fastened directly to the truck bed. It is the users responsibility to provide an adequate means of fastening the unit in these applications.
CAUTION !
Do not operate this compressor more than 15 off level or move it while it is operating.
System components
Efficiency and safety are the primary concerns when selecting components for compressed air systems. Products of inferior quality can not only hinder performance of the unit, but could cause system failures that result in bodily harm or even death. Select only top quality components for your system. Call your local Quincy distributor for quality parts and professional advice. Drive Pulleys / Sheaves Various pulley and sheave combinations are available to obtain the desired air pressure and delivery rate of your compressor. Consideration must be given to these combinations to ensure that the motor is not overloaded by operating above or below the designed speed range. Whatever combination is employed, the drive pulleys & compressor sheaves must be properly aligned and drive belt tension set to specifications (refer to SECTION 5, Pulley / Sheave Alignment & Belt Tension). Improper pulley/ sheave alignment and belt tension can cause motor overloading, excessive vibration, and premature belt and/or bearing failure.
WARNING !
Excessive compressor RPMs (speed) could cause a pulley or sheave to shatter. In an instant, the pulley or sheave could separate into fragments capable of penetrating the belt guard and causing bodily harm or death. Do not operate the compressor above the recommended RPM (refer to SECTION 2, Specifications). Guards All mechanical action or motion is hazardous in varying degrees and needs to be guarded. Guards should be designed to achieve the required degree of protection and still allow full air flow from the compressor sheave across the unit. Guards shall be in compliance with OSHA safety and health standards 29 CFR 1910.219 in OSHA manual 2206 and any state or local codes.
WARNING !
Guards must be fastened in place before starting the compressor and never removed before cutting off and locking out the main power supply. Check Valves Check valves are designed to prevent back-flow of air pressure in the compressed air system (air flows freely in one direction only). The check valve must be properly sized for air flow and temperature. Do not rely upon a check valve to isolate a compressor from a pressurized tank or compressed air delivery system during maintenance procedures! Manual Shutoff Valves Manual shutoff valves block the flow of air pressure in either direction. This type of valve can be used to isolate a compressor from a pressurized system, provided the system is equipped with a pressure relief valve capable of being manually released. The pressure relief valve should be installed between the manual shutoff valve and the compressor (refer to Fig. 3-8, Typical Drop Leg & Component Location). Pressure Relief Valves Pressure relief valves aid in preventing system failures by relieving system pressure when compressed air reaches a determined level. They are available in various pressure settings to accommodate a range of applications. Pressure relief valves are preset by the manufacturer and under no circumstances should the setting be changed by anyone other than the manufacturer. Pressure relief valves are designed to protect compressed air systems in accordance with ASME B19 safety standards. Failure to provide properly sized pressure relief valves may cause property damage, severe personal injury or even death. Pressure Switch The pressure switch detects the demand for compressed air and allows the motor to start. When the demand is satisfied, the unit stops. Pressure switches provided by Quincy Compressor are pre-set at the factory and usually do not require adjustment.
DANGER !
Induction System
Air Intake A clean, cool and dry air supply is essential to the satisfactory operation of your Quincy QT or PLT Series air compressor. The standard air filter that the compressor is equipped with when leaving the factory is of sufficient size and design to meet normal conditions, when properly serviced, in accordance with the maintenance section of this manual. If, however, the compressor is to be installed in a location where considerable dust, dirt and other contaminants are prevalent, consult your local Quincy distributor for advice and optional filters. A condensate trap must be installed as close as possible to the inlet filter if, as a result of installation or environmental conditions, there is any risk of moisture forming in the inlet piping. It is the users responsibility to provide adequate filtration for those conditions. Oil bath filters are not to be used. Warranty will be void if a failure is determined to be caused by inadequate filtration. Remote Inlet Filters (does not apply to Xtreme cabinet units) Depending on the size of the compressor and the size and construction of the room in which the unit operates, the air inlet may have to be located outside of the room. If it is necessary to remotely install the air filter, make the inlet piping as short and direct as possible. Remotely installed air filters can lead to vibrations in the inlet piping. These vibrations can be minimized by adding a pulsation dampener in the inlet piping between the remote inlet filter(s) and the compressor. If the inlet is routed to outside atmosphere, the inlet piping should be equipped with a hooded air filter and designed to prevent condensate, water or snow from being injested into the compressor. All inlet piping should be at least the same size (or larger) in diameter as the inlet connection to the compressor. For every 10 feet of inlet piping or every 90 bend, increase the inlet piping diameter by one pipe size. The inlet piping must be thoroughly clean inside. Remove all weld slag, rust or dirt. Galvanized pipe with threaded or flanged fittings is preferred. Never locate the compressor air inlet system where toxic, volatile or corrosive vapors, air temperatures exceeding 100F, water, or extremely dirty air could be ingested. These types of atmospheres could adversely affect the performance of the compressor system.
CAUTION !
where moisture can be easily removed. All service line outlets should be installed above the moisture traps to prevent moisture from entering the tool or device using the air. Manual shutoff valves, protected by pressure relief valves, should be installed at all service line outlets to eliminate leakage while the tools are not in use.
Pix 1007-004
As with any piping, all parts of the discharge piping should fit so as not to create any stress between the piping and components. Pneumatic Circuit Breakers or Velocity Fuses The Occupational Safety and Health Act (OSHA), Section 1926.303, Paragraph 7, published in the Code of Federal Regulations 29 CFR 1920.1, revised July 1, 1982 states that all hoses exceeding 1/2" inside diameter shall have a safety device at the source of supply or branch line to reduce pressure in case of a hose failure These pneumatic safety devices are designed to prevent hoses from whipping and/or the loss of hazardous or toxic gasses, all of which could result in a serious or fatal accident.
WARNING !
Never join pipes or fittings with lead-tin soldering. Welded or threaded steel pipes and cast iron fittings, designed for the pressures and temperatures, are recommended. Pressure Vessels Air receiver tanks and other pressure containing vessels such as (but not limited to) pulsation bottles, heat exchangers, moisture separators and traps, must be in accordance with ASME Boiler and Pressure Vessel Code Section VIII and ANSI B19.3 safety standards. They must be equipped with a properly sized pressure relief valve, pressure gauge, tank drain, & manual shutoff valve (refer
to Fig. 3-8, Typical Drop Leg & Component Location). Follow ASME code for air reciever tanks and other pressure containing vessels. Pressure vessels must not be modified, welded, repaired, reworked or subjected to operating conditions outside the nameplate ratings. Such actions will negate code status, affect insurance status and may cause property damage, severe injury or even death. A drain valve should be located in the bottom of the air receiver to allow for moisture drainage. An automatic drain valve is recommended. Extend piping away from the unit and any personnel in the immediate area to provide safe and convenient removal of excess moisture. If the air receiver is going to be subject to temperatures of 32F or below, provisions must be made to guard against freezing of the pressure relief valves, check valves, pressure gauge, and moisture drain. Condensation Rust can form inside the crankcase and on internal components as a result of condensation. A compressor must operate long enough during each run cycle to reach full operating temperature in order to reduce the risk of condensation.
WARNING !
CAUTION !
Lubricant that appears milky on the dipstick may have mixed with condensate. Failure to replace contaminated lubricant will result in damage to the compressor and may void warranty. Condensation can also form in the air tank of your compressor. When this happens, a mixture of air and moisture will be expelled through the service valve and into whatever is connected to the valve (e.g. air hoses, metal air lines, pneumatic tools, spray guns). An in-line filter or dryer, available from your local Quincy distributor, may be required to eliminate the moisture. Condensation in the air tank can be kept to a minimum by draining the tank on a daily basis. This also reduces the risk of rust developing and weakening the tank.
30 PSIG
Pix 1224
Manual Tank Drain Valve Operation The manual tank drain valve on portable compressors and some stationary compressors is located on the underside of the air tank. Portable compressors can be tilted in the direction of the drain to allow removal of tank moisture. Some tanks use an internal drain tube (Refer to Fig. 3-9, Internal Drain Tube) to drain the moisture. Tank pressure is required to force moisture out of the tank through the drain tube. Safe removal of tank moisture from the air tank is dependent upon an internal tank pressure of no more than 30 PSIG. Higher internal tank pressures are dangerous and could cause serious injury!
Oil and moisture residue must be drained from the air receiver daily or after each use. Accumulations of oil residue in the receiver can be ignited by embers of carbon created by the heat of compression, causing an explosion, damage to property and injury to personnel. Do not open a manual tank drain valve on any air tank containing more than 30 PSIG of air pressure! Never attempt to relieve an air tank by removing a pipe plug or any other system component!
Manually Draining An Air Tank: Step 1) Disconnect & lockout the compressor from the power source (electric models) or disconnect the spark plug wire from the spark plug (gas engine models). Step 2) Tanks subjected to freezing temperatures may contain ice. Store the compressor in a heated area before attempting to drain moisture from the tanks. Reduce the air pressure in the tank to 30 PSIG by pulling the pressure relief valve ring (refer to Fig. 3-10, Checking Pressure Relief Valves & Relieving System Pressure). Step 3) Open the drain valve and allow the moisture and air mixture to drain from the tank.
Fig. 3-10 Checking Pressure Relief Valves & Relieving System Pressure
Pix 1160
Step 4) Once the moisture has been completely drained, close the drain valve.
SECTION 4
Pre-starting Checklist
WARNING ! WARNING !
Step 2)
Step 3)
Step 4)
Step 5)
Step 6)
Step 7) Step 8)
Step 9)
Step 10)
Step 11)
Step 12)
(Xtreme Units)-Make sure all panels are securely mounted and fastened, the door is properly installed and latches are secured. After all the above conditions have been satisfied, the unit can be connected to the proper power source.
Step 13)
Xtreme Units (only) Step 14 Remove the front door. The rotation arrow on top of the motor must point towards the compressor. Jog the starter switch to check the rotation of the motor fan and pulley. The motor fan must blow cooling air towards the motor. Reinstall the front door and secure the latches.
Step 15
QT & PLT Compressor Units (only) Step 14) Jog the starter switch to check the rotational direction of the compressor. It should agree with the rotation arrow embossed on the compressor sheave. Check for proper rotation of the cylinder cooling fan (fins inside sheave). The fan should blow cooling air across the cylinder.
Step 15)
Check the air receiver pressure gauge or system pressure gauge for proper readings. If inadequate or excessive air pressure conditions exist, refer to Section 6 Troubleshooting. Observe compressor operation closely for the first hour of operation and then frequently for the next seven hours. After the first eight hours, monitor the compressor at least once every eight hours. If any abnormal conditions are
witnessed, stop the compressor and correct the problem. After two days of operation check belt tension, lubricant level, and inspect the system for leaks. A new or rebuilt reciprocating compressor should be run for a total of 100 hours at full discharge operating pressure to break-in the new piston rings. Until the rings are seated, the compressor will discharge higher than normal amounts of lubricant. In light of this fact, the lubricant level should be checked more frequently during the 100 hour break-in period.
Start compressor per factory instructions. (Refer to SECTION 4, Pre-Starting Checklist and Initial Starting & Operating.) Check system pressure.
The following steps apply to QT & PLT compressors as well as Xtreme Units. On Xtreme Units, remove the front door to complete Steps 6-9. After start-up, replace the door and secure the quarter turn latches. Step 6) Step 7) Step 8) Step 9) Check cooling fan. Check all pressure relief valves for proper operation. Check control system for proper operation. Check the lubricant level in the crankcase several minutes after the compressor has run. (Discoloration or a higher lubricant level reading may indicate the presence of condensed liquids.) If lubricant is contaminated, drain and replace.
SECTION 5
Stopping for Maintenance
WARNING !
Never assume a compressor is safe to work on just because it is not operating. It could restart at any time. Step 2) Isolate the compressor from the compressed air supply by closing a manual shutoff valve upstream and downstream from the compressor. Display a sign in clear view at the shutoff valve stating that the compressor is being serviced. Lock open a pressure relief valve within the pressurized system to allow the system to be completely de-pressurized. NEVER remove a plug to relieve the pressure! Open all manual drain valves within the area to be serviced. Wait for the unit to cool before starting to service. (Temperatures of 125F can burn skin. Some surface temperatures exceed 350F when the compressor is operating.)
Step 3)
Step 4) Step 5)
Maintenance Schedule
To assure maximum performance and service life of your compressor, a routine maintenance schedule should be developed. A sample schedule has been included here to help you to develop a maintenance schedule designed for your particular application. Time frames may need to be shortened in harsher environments. At the back of this instruction manual you will find a Maintenance Schedule Checklist. Make copies of this checklist and retain the master to make more copies as needed. On a copy of the checklist, enter dates and initials in the appropriate spaces. Keep the checklist and this Instruction Manual readily available near the compressor.
densed liquids.) If lubricant is contaminated, drain and replace. Drain receiver tank, drop legs and traps in air distribution system. Receiver tanks subjected to freezing temperatures may contain ice. Store the compressor unit in a heated area before attempting to drain moisture from the tank. Give compressor an overall visual inspection and be sure safety guards are in place. Check for any unusual noise or vibration. Check for lubricant leaks. Check all pressurized components for rust, cracks or leaks. Immediately discontinue use of the equipment and relieve all system pressure if any of these problems are discovered. Do not use the equipment until it has been inspected and repaired by a qualified mechanic. Every 40 Hours (or Weekly) Manually operate the pressure relief valves to be certain they are working. Clean the cooling surfaces of the intercooler, aftercooler and compressor. Check the compressor for air leaks. Check the compressed air distribution system for leaks. Inspect lubricant for contamination & change if necessary. Clean or replace the air intake filter. Check more often under humid or dirty conditions. Every 160 Hours (or Monthly) Check belt tension Every 500 Hours (or Every 3 Months) Change lubricant (more frequently in harsher environments). Torque pulley clamp screws or jamnut. Every 1000 Hours (or Every 6 Months) When Quin-Cip or Quin-Cip-D lubricant is used, lubricant change intervals may be extended to every 1000 hours or every 6 months, whichever occurs first (change more frequently in harsher conditions). Inspect compressor valves for leakage and/or carbon build-up. If excessive sludge build-up exists inside the crankcase, clean the inside of the crankcase as well as the screen. Never use a flammable or toxic solvent for cleaning. Always use a safety solvent and follow the directions provided. Every 2000 Hours (or Every 12 Months) Inspect the pressure switch diaphragm and contacts. Inspect the contact points in the motor / starter. Servicing Reed Valves QT & PLT Series compressor valve plates and reed valves should be inspected and cleaned on a regular basis. The reed valves are made of stainless steel and can be cleaned with a stiff bristle brush(not a wire brush!). A clean safety solvent may also be used to loosen carbon deposits on the valve plates and reed valves. Handle all parts with care; do not bend, mar or scratch any sealing surfaces.
DANGER !
QT & PLT Series 50161-106, January 2009
Never use gasoline, thinners, or other flammable solutions to clean valves or related parts.
Quincy Compressor 28 3501 Wismann Lane, Quincy Ill. - 62305-3116
Lubrication
QT and PLT Series basic compressors and units are normally shipped from the factory with break-in lubricant in the crankcase. Before starting your compressor, check the lubricant level in the crankcase. The lubricant level of QT-5, PLT-5, QT-7.5, PLT-7.5, QT-10 and PLT-10 compressors must be kept at the top of the sightglass. The lubricant level of QT-15, PLT-15, QT-30 & QT-54 compressors must register between the high and low marks on the dipstick. Replace the break-in lubricant after 100 hours of operation with Quin-Cip lubricant - use Quin-Cip-D in Xtreme models. Quin-Cip and Quin-Cip-D lubricants have proven under extensive testing to minimize friction and wear, limit lubricant carryover, and reduce carbon and varnish deposits. They will support the performance characteristics and life designed into all Quincy compressors and are highly recommended. Refer to the charts below to determine the correct amount of lubricant and viscosity to use for your model and application. Approximate Crankcase Lubricant Capacities Basic Compressor Model QT-5 & PLT-5 (incl. Xtreme models) QT-7.5 & PLT-7.5 (incl. Xtreme models) QT-10 & PLT-10 (R.C. 200) QT-30 QT-15 & PLT-15 QT-54 Lubricant Capacity 1.62 qts. (1.5 lit.) 1.62 qts. (1.5 lit.) 2.50 qts. (2.37 lit.) 9 qts. (8.51 lit.) 3.75 qts. (3.6 lit.) 1.25 qts. (1.15 lit.)
Lubricant Specifications For QT & PLT models use Quin-Cip or consult factory. Ambient Temperature Below 0F 0-32 F 32-80F 60-104F SAE Viscosity SAE 5W SAE 10W SAE 20W SAE 30 ISO Viscosity ISO 22 ISO 32 ISO 68 ISO 100
For Xtreme models use Quin-Cip-D or consult factory. Ambient Temperature 10-104F SAE Viscosity SAE 30 ISO Viscosity ISO 100
CAUTION ! CAUTION !
QT & PLT Series 50161-106, January 2009
The lubricant selected must have a pour point at least 15 F lower than the minimum expected ambient temperature . Do not operate this compressor in ambient temperatures lower than -15 F. A crankcase heater is recommended for compressors operating in temperatures under 32 F.
Quincy Compressor 29 3501 Wismann Lane, Quincy Ill. - 62305-3116
Fig. 5-1
Pix 1152
Setting Belt Tension Belt Cross Section A B B B B Motor Pulley Dia. Range (inches) QT-54 only 4.6 5.0 - 5.4 5.6 - 6.4 6.8 - 9.4 Recommended Deflection Force (lbs.) Minimum Maximum 2 4.0 4.5 5.0 5.8 3 5.9 6.7 7.4 8.6
POCKET CLIP
Step 2) Determine the amount of deflection ( in inches) required to measure deflection force (in pounds) by multiplying the span length x 1/64 (.016) (i.e. 32 span length x 1/64 [.016] = 1/2[.50] of deflection required to measure deflection force). Step 3) Lay a straightedge across the top outer surface of a drive belt from pulley to sheave.
Step 4) At the center of the span, perpendicular to the belt, apply pressure to the outer surface of the belt with a belt tension gauge (refer to Fig. 5-2, Belt Tension Gauge). Force the belt to the predetermined deflection (refer to Step 2 above). Record the reading on the belt tension gauge and compare to the chart following Fig 5-1. The deflection force reading should be within the minimum and maximum values shown. Adjust belt(s) accordingly. New belts should be initially tensioned to the maximum value plus 33% (multiply by 1.33).
Pix 1153
ELECTRICAL CONTACTS
Step 5) Recheck the tension of the new belts several times in the first 50 hours of operation and adjust if necessary. Thereafter, check belt tension on a regular basis (refer to SECTION 5, Maintenance Schedule).
Step 1)
Step 2) While the compressor is running, screw the spring loaded adjustment screw in (clockwise) to increase the amount of air pressure required to open the switch and stop the unit. Screw the spring loaded adjustment screw out (counterclockwise) to decrease the amount of air pressure required to open the switch and stop the unit. Standard pressure switches supplied by Quincy Compressor are equipped with a fixed 20 PSIG (approx.) differential. Optional switches include both pressure and differential adjustment capabilities. Electric power always exists inside the pressure switch whenever the compressor package is connected to a power supply. Be careful not to touch any electrical leads when adjusting the pressure switch.
WARNING !
WARNING !
Never exceed the designed pressure for the system or overload the motor beyond its Maximum Amp Draw. * Full Load Amps x Service Factor = Maximum Amp Draw Never assume a compressor is safe to work on just because it is not operating. It may be in the automatic stand-by mode and may restart any time. Follow all safety precautions outlined in SECTION 5, Stopping For Maintenance.
WARNING !
* Full load amps (FLA) & Service Factor can usually be found on the motor nameplate. Reference torque spec. note in parts book corresponding to Record of Change for your compressor.
QT & PLT Series 50161-106, January 2009 32 Quincy Compressor 3501 Wismann Lane, Quincy Ill. - 62305-3116
WARNING !
The pressure switch and / or pilot valve are set at the factory for maximum efficiency. Adjustments to either component must be performed by a qualified technician. Exceeding the factory recommended maximum pressure will void the warranty and may cause personal injury.
Setting Unload Pressure Step 1. Flip the toggle to the "RUN" position as shown, or turn the knurled knob (if so equipped) counterclockwise until it stops. * Step 2. Loosen locknut (counterclockwise). * Stabilize with back-up wrench!
"MANUAL UNLOAD" position (Ref.)
Step 3.
Turn clockwise to increase unload pressure, turn counterclockwise to decrease unload pressure. Hold position with wrench and proceed to Step 4. Tighten locknut (clockwise) with wrench. * Stabilize with back-up wrench!
Step 4.
Setting Differential Pressure Step 6. * Step 5. Loosen locknut (counterclockwise). * Stabilize with back-up wrench! Turn clockwise to decrease the differential pressure and counterclockwise to increase the differential pressure. Hold position with wrench and proceed to Step 7. Tighten locknut (clockwise) with wrench. * Stabilize with back-up wrench!
Step 7.
SECTION 6
Trouble
Low discharge pressure
TROUBLESHOOTING
Probable Cause
Restricted inlet Defective compressor valves or valve unloading mechanism Leaks in the compressed air distribution system at fittings, connections, etc. Unloader pilot valve defective or set wrong Pressure switch defective or set wrong Drive belt slipping Incorrect speed Worn piston rings or loose piston Leaking head gasket Drain valve open Defective pressure gauge Excessive running clearances (refer to SECTION 2, Specifications) Pressure relief valve leaking Clogged intercooler Loose compressor valves or leaking at valve gaskets Compressor incorrectly sized for the altitude it is operating at Piston rings not seated; allow 100 hours at full pressure
Compressor does not run long enough to get hot and vaporize the liquids squeezed out of the air during compression (compressor may be too large for application) Incorrect or inferior grade of lubricant System pressure leaking back through discharge valve
Compressor operated too infrequently Compressor does not run long enough to get hot and vaporize the liquids squeezed out of the air during compression (compressor may be too large for application) Compressor not properly prepared for storage Discharge line from compressor head is pointed upward allowing con densation to drain back at shutdown
Excessive vibration
Incorrect speed Compressor valves not functioning properly Loose pulley/sheave Motor or engine out of balance Compressor, motor or engine not secured tightly, or tightened into a bind Foundation or frame inadequate Piping inadequately supported or tightened into a bind Excessive discharge pressure Compressor feet may need to be leveled with shims
Trouble
Excessive drive belt wear
Probable Cause
Pulley/sheave out of alignment Belt too loose or too tight Belt slipping Pulley/sheave wobbling Pulley/sheave groove damaged or rough Incorrect belts
Oil sump strainer plugged Excessive leakage at crankshaft seals Low oil level Oil pump incorrectly assembled to the bearing carrier (oring not properly located between oil pump body & bearing carrier) Oil pressure adjusting screw not set properly Defective oil pressure gauge
Air receiver too small Compressor valves or unloaders defective Excessive system leakage Compressor operating at incorrect speed Unloader pilot differential set too close Pressure switch defective
Defective pressure switch Moisture &/or oil buildup on the pressure switch diaphragm Ruptured diaphragm Burned contact points Plugged air passage from the receiver to the pressure switch Loose electrical connection
Air pressure gauge inaccurate Leaks in unloader piping system Defective compressor head unloader Pilot valve or pressure switch set incorrectly or defective Pressure switch wired incorrectly Tube to compressor head unloader plugged
Intercooler restricted or plugged Compressor valves in second stage broken or not functioning properly Pilot valve or pressure switch set incorrectly or defective Pressure gauge defective
Trouble
Intercooler pressure abnormally low (Two stage models only)
Probable Cause
Compressor valves or head unloaders in first stage not functioning properly or defective Restricted air inlet filter or suction line Pilot valve or pressure switch set incorrectly or defective Pressurized air at head unloader not venting properly when demand for air is required Compressor valve or head gasket leaking Worn piston rings Defective pressure gauge Leaking air at intercooler or intercooler connections
Compressor overheats
Clogged intake system Defective compressor valves Pressure setting too high Clogged intercooler, internally or externally Inadequate ventilation, or recirculation of hot air Pulley/sheave rotation wrong Incorrect speed Running clearances insufficient (piston to cylinder wall or running gear) Lubrication inadequate Compressor incorrectly sized
Compressor valve assemblies defective Discharge pressure too high Inadequate ventilation or hot air recirculating Cooling surfaces of compressor or intercooler excessively dirty Internal surface of heat exchanger fouled Ambient temperature too high Scored or excessively worn cylinder walls
Compressor knocks
Head clearance insufficient Piston loose in cylinder bore, cylinder bore worn, piston or piston rings worn Worn rods or main bearing Wrong pressure setting, discharge pressure excessive Crankcase lubrication inadequate Loose pulley/sheave Compressor valve assemblies loose
Trouble
Probable Cause
Excessive oil consumption Compressor runs unloaded too long Worn piston rings Restricted intake system Compressor running too hot Breather valve not functioning properly Oil level in crankcase too high Oil viscosity wrong for the application Connecting rod out of alignment, bent or twisted Leaking oil seal Piston rings not seated (allow 100 hours for seating) Wrong oil (may be a detergent oil with a tendency to foam) Inferior grade of oil
Excessive current draw (To determine maximum amperage allowed, multiply the FLA on the motor nameplate by the service factor.) CAUTION ! Motor surface temperature normally exceeds 170 F.
Low voltage (must be within 10% of nameplate voltage) Loose electrical connection Wire size too small Incorrect oil Discharge pressure too high Intercooler plugging Bearings tight or seizing No crankshaft endplay Motor sized incorrectly Motor defective Drive belts too tight
Failure to start
Power not on Blown circuit fuse Thermal overload fuses tripped Low voltage Faulty start switch Power failure Pressure switch incorrectly adjusted or faulty Loose or broken wire Motor defective Compressor seized
Motor stalls
SECTION 7
Decal Locations
REFERENCE INFORMATION
Typical QT & PLT Series Engine Driven Unit with Horizontal Receiver
responsible for loss or damage in transit after having received In Good Order receipt from the carrier. All claims for loss or damage in transit should be made to the carrier. TITLE & LIEN RIGHTS: The equipment shall remain personal property, regardless of how affixed to any realty or structure. Until the price (including any notes given therefore) of the equipment has been fully paid in cash, Seller shall, in the event of Buyers default, have the right to repossess such equipment. PATENT INFRINGMENT: If properly notified and given an opportunity to do so with friendly assistance, Seller will defend Buyer and the ultimate user of the equipment from any actual or alleged infringement of any published United States patent by the equipment or any part thereof furnished pursuant hereto (other than parts of special design, construction, or manufacture specified by and originating with Buyer), and will pay all damages and costs awarded by competent court in any suit thus defended or of which it may have had notice and opportunity to defend as aforesaid. STANDARD WARRANTY: Seller warrants that products of its own manufacture will be free from defects in workmanship and materials under normal use and service for the period specified in the product instruction manual. Warranty for service parts will be Ninety (90) days from date of factory shipment. Electric Motors, gasoline and diesel engines, electrical apparatus and all other accessories, components and parts not manufactured by Seller are warranted only to the extent of the original manufacturers warranty. Notice of the alleged defect must be given to the Seller, in writing with all identifying details including serial number, type of equipment and date of purchase within thirty (30) days of the discovery of the same during the warranty period. Sellers sole obligation on this warranty shall be, at its option, to repair or replace or refund the purchase price of any product or part thereof which proves to be defective. If requested by Seller, such product or part thereof must be promptly returned to seller, freight prepaid, for inspection. Seller warrants repaired or replaced parts of its own manufacture against defects in materials and workmanship under normal use and service for ninety (90) days or for the remainder of the warranty on the product being repaired. This warranty shall not apply and Seller shall not be responsible or liable for: (a) Consequential, collateral or special losses or damages; (b) Equipment conditions caused by fair wear and tear, abnormal conditions of use, accident, neglect or misuse of equipment, improper storage or damage resulting during shipping; (c)Deviation from operating instructions, specifications or other special terms of sale; (d) Labor charges, loss or damage resulting from improper operation, maintenance or repairs made by person(s) other than Seller or Sellers authorized service station. In no event shall Seller be liable for any claims whether arising from breach of contract or warranty or claims of negligence or negligent manufacture in excess of the purchase price. THIS WARRANTY IS THE SOLE WARRANTY OF SELLERS AND ANY OTHER WARRANTIES, WHETHER EXPRESS OR IMPLIED IN LAW OR IMPLIED IN FACT, INCLUDING ANY WARRANTIES OF MERCHANTABILITY AND FITNESS FOR PARTICULAR USE ARE HEREBY SPECIFICALLY EXCLUDED. LIABILITY LIMITATIONS: Under no circumstances shall the Seller have any liability for liquidated damages or for collateral, consequential or special damages or for loss of profits, or for actual losses or for loss of production or progress of construction, whether resulting from delays in delivery or performance, breach of warranty, negligent manufacture or otherwise. ENVIROMENTAL AND OSHA REQUIREMENTS: At the time of shipment of the equipment from the factory, Quincy Compressor / Ortman Fluid Power will comply with the various Federal, State and local laws and regulations concerning occupational health and safety and pollution. However, in the installation and operation of the equipment and other matters over which the seller has no control, the Seller assumes no responsibility for compliance with those laws and regulations, whether by the way of indemnity, warranty or otherwise. June 30, 2003 Quincy Compressor 3501 Wismann Lane, Quincy Ill. - 62305-3116
Maintenance Procedures
manually test pressure relief valves clean surfaces of intercooler check distribution system for leaks check for contaminated lubricant * check for compressor/vacuum leaks
10
11
12
Maintenance Procedures
check belt tension (if applicable) torque sheave fasteners (if applicable) change lubricant (& filter if applicable)*
50253-100 mnchklst.doc