PERENNITY DICOM v4.
00 New Features & Improvements
Copyright Perennity sprl-bvba 2004-2011
General Overview
Simplified installation/upgrade procedure
Improved support for Windows 7 & 64-bit platforms
Flexible activity reporting Storage management Data replication Transfer of studies/series to remote AETs Editing of DICOM tags Custom menu Diagnostic reports in PDF Perennity Dicom Server available as an Applet Auto-warming up of Everest printer Worklist filtered on AET Additional languages Improved DICOM Server user interface Improved log display
Copyright Perennity sprl-bvba 2004-2011
Simplified Installation Disc
New simplified Next-Next-Next wizard
Complete installation performed in less than 5 minutes Important required parameters (e.g. storage path) are entered during the installation Automatic configuration of the CD robot (e.g. automatically detects type of printer)
The installation package now includes and installs all required components
JAVA Virtual Machine (JVM)
Perennity requires JVM v6 update 23 or higher If JAVA is already installed the version is check prior to install Perennity
MySQL Database engine Apache Tomcat Web Server Perennity DICOM Sender with one study for test purpose Includes the SDK/APIs toolkit if required (e.g. Epson & Primera robots)
Improved support for Windows 7
All settings are now stored in Documents and Settings folder
Requirement for Windows 7 security
IQ-Lite 2.7 fully supports Windows 7
3
Copyright Perennity sprl-bvba 2004-2011
Simplified Installation Disc
8 different installation CD packages
One installation package per robot vendor
Rimage Epson
Includes the installation of TD-Bridge Checks the version of Epson software
Primera
Includes the Primera SDK Checks the version of Primera software
Perennity DICOM Level 1B
Perennity DICOM Server only No supporting robots
32bit and 64bit packages
Installs the right JAVA Virtual Machine (JVM) Installs the right Apache Web Server
4
Copyright Perennity sprl-bvba 2004-2011
Simplified Installation
Straightforward installation wizard
Copyright Perennity sprl-bvba 2004-2011
Configuration Files
Now located in Document & Settings Required for Windows 7 compatibility
Copyright Perennity sprl-bvba 2004-2011
Reporting
New tool for a Leasing Solution Print or export (PDF, XLS, ) activity reports
List of Patient CDs per day Statistics
Reports can easily be customized
Using user friendly free iReport report design tool
Add you own reports
Create any kind of report using iReport Include parameters (e.g. date range) without writing a line of code
All reports, standard and customized, are available from the Report menu
In the Perennity Dicom Burner Using the Perennity Dicom Burner Applet in a web browser
7
Copyright Perennity sprl-bvba 2004-2011
Reporting
Copyright Perennity sprl-bvba 2004-2011
Storage Management
Pre- PACS Ready Data replication
All DICOM studies sent to Perennity are stored locally A copy can automatically be made to secondary storage
NAS (Network Attached Storage) Silent Cube for long term archiving External cost-effective HDD Network share on a server All we need is a UNC path !
Study deletion is performed by the Dicom Server
You may still decide how many days you want to keep the images Expired images were formerly deleted by the Dicom Burner Makes more sense to delegate deletion process to the Dicom Server
Perennity Level 1B (archive only) does not have the Dicom Burner
History is always kept in the database
Used to be an option
Copyright Perennity sprl-bvba 2004-2011
Data Replication
Copyright Perennity sprl-bvba 2004-2011
10
Transfer Studies to Remote AETs
New button in the Dicom Burner interface Examples
Transfer studies to a Diagnostic Workstation Transfer studies to a central PACS
Copyright Perennity sprl-bvba 2004-2011
11
Editing DICOM Tags
Edit Studies information (e.g. patient name, ID, ) All changes are accurately logged
e.g. Study123: patient name was Smith changed to Johnson Must be activated in the configuration file of the Dicom Burner
Option is disabled by default
Copyright Perennity sprl-bvba 2004-2011
12
Custom Startup Menu on Patient CD
Automatically launched by the autorun Provide the list of the studies contained on the disc Direct link to PDF report Preview of images (JPEG)
Fast access for reviewing the studies
Enable the autorun which is disabled by default in Windows 7
Copyright Perennity sprl-bvba 2004-2011
13
Custom Startup Menu on Patient CD
Very easy to customize
Change the background The size of the image defines the size of the menu window Customize up to three buttons Text Icon Application (e.g. html page, executable, PDF, ) Position & size Position the list of the study anywhere in the window
Simply edit an .ini file
Copyright Perennity sprl-bvba 2004-2011
14
Diagnostic Reports in PDF
Retrieved reports from a RIS/PACS or/and DICOM Structured Report sent to Perennity are now converted to PDF and added to the Patient CDs PDF report is accessible using our custom menu
Copyright Perennity sprl-bvba 2004-2011
15
Perennity Dicom Server Applet
Access the DICOM Server user interface using any web browser
Remote monitoring and configuration of the DICOM Server
Copyright Perennity sprl-bvba 2004-2011
16
Auto Warm-up of Everest
Everest printers are put to sleep after 45 minutes
Save power and improve longevity Warming up process can take up to 5 minutes
Perennity wakes up the printer when receiving a new study
Dramatically improves performance Everest is warming up while images are pre-processed Reduced waiting time for the CD printing any longer Definitely efficient when performing long examinations
e.g. MRI
Copyright Perennity sprl-bvba 2004-2011
17
Improved Support of Worklists
Generate Patient CD on request using the RIS
Perennity is listening to the Worklist of a RIS Filter inputs based on DICOM Burner AET(s) Perennity processes studies that have been added to the Worklist
Retrieve the images belonging to the study Create a Patient disc
Feedback to the RIS once the Patient CD has been produced (MPPS)
Copyright Perennity sprl-bvba 2004-2011
18
Languages
New languages
German
Updates
Brazilian Portuguese Chinese Russian
Language can now be defined when using the Dicom Burner Applet in a web browser
Copyright Perennity sprl-bvba 2004-2011
19
Improved Dicom Server GUI
Password protected New System tab
Shows IP settings
Detailed explanation for each tab
Copyright Perennity sprl-bvba 2004-2011
20
Improve Logs Display
Always displays the last 100 events Does not empty the log window at each restart of the DICOM Burner and Server
Copyright Perennity sprl-bvba 2004-2011
21
Licensing and Downloading
Trial mode
The 2 hours trial mode has been removed You can only send 25 images without a valid activation key (unlimited or demo)
Download of Perennity DICOM has been removed from our web site
We need to know who is downloading what Avoid end-users to upgrade themselves Download links can be requested by email
license@perennitysoft.com
A form will be available soon on our web site
Copyright Perennity sprl-bvba 2004-2011
22
Contact Information
Copyright Perennity sprl-bvba 2004-2011
23