Understanding Damping Ratio Basics

The damping ratio is a dimensionless measure used in engineering to describe how oscillations in a system decay over time after a disturbance. It is a ratio of the damping coefficient to the critical damping coefficient. Undamped systems oscillate indefinitely, overdamped systems do not oscillate at all, and underdamped systems oscillate but the oscillations decay towards zero with each cycle. The damping ratio determines whether a system is underdamped, overdamped, or critically damped. It provides a standardized way to characterize oscillating systems across various engineering disciplines.
Copyright
© Attribution Non-Commercial (BY-NC)
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
100% found this document useful (1 vote)
489 views4 pages

Understanding Damping Ratio Basics

The damping ratio is a dimensionless measure used in engineering to describe how oscillations in a system decay over time after a disturbance. It is a ratio of the damping coefficient to the critical damping coefficient. Undamped systems oscillate indefinitely, overdamped systems do not oscillate at all, and underdamped systems oscillate but the oscillations decay towards zero with each cycle. The damping ratio determines whether a system is underdamped, overdamped, or critically damped. It provides a standardized way to characterize oscillating systems across various engineering disciplines.
Copyright
© Attribution Non-Commercial (BY-NC)
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 4

Damping ratio

Damping ratio
Classical mechanics

History Timeline

In engineering, the damping ratio is a dimensionless measure describing how oscillations in a system decay after a disturbance. Many systems exhibit oscillatory behavior when they are disturbed from their position of static equilibrium. A mass suspended from a spring, for example, might, if pulled and released, bounce up and down. On each bounce, the system is "trying" to return to its equilibrium position, but overshoots it. Sometimes losses (e.g. frictional) damp the system and can cause the oscillations to gradually decay in amplitude towards zero. The damping ratio is a measure of describing how rapidly the oscillations decay from one bounce to the next. The behaviour of oscillating systems is often of interest in a diverse range of disciplines that include control engineering, mechanical engineering, structural engineering and electrical engineering. The physical quantity that is oscillating varies greatly, and could be the swaying of a tall building in the wind, or the speed of an electric motor, but a normalised, or non-dimensionalised approach can be convenient in describing common aspects of behavior.

Oscillation modes
Where the springmass system is completely lossless, the mass would oscillate indefinitely, with each bounce of equal height to the last. This hypothetical case is called undamped. If the system contained high losses, for example if the springmass experiment were conducted in a viscous fluid, the mass could slowly return to its rest position without ever overshooting. This case is called overdamped. Commonly, the mass tends to overshoot its starting position, and then return, overshooting again. With each overshoot, some energy in the system is dissipated, and the oscillations die towards zero. This case is called underdamped.

Underdamped springmass system with <1

Between the overdamped and underdamped cases, there exists a certain level of damping at which the system will just fail to overshoot and will not make a single oscillation. This case is called critical damping. The key difference between critical damping and overdamping is that, in critical damping, the system returns to equilibrium in the minimum amount of time.

Damping ratio

Definition
The damping ratio is a parameter, usually denoted by (zeta),[1] that characterizes the frequency response of a second order ordinary differential equation. It is particularly important in the study of control theory. It is also important in the harmonic oscillator. The damping ratio provides a mathematical means of expressing the level of damping in a system relative to critical damping. For a damped harmonic oscillator with mass m, damping coefficient c, and spring constant k, it can be defined as the ratio of the damping coefficient in the system's differential equation to the critical damping coefficient:

The effect of varying damping ratio on a second-order system.

where the system's equation of motion is

and the corresponding critical damping coefficient is

or

The damping ratio is dimensionless, being the ratio of two coefficients of identical units.

Derivation
Using the natural frequency of the simple harmonic oscillator above, we can rewrite this as: and the definition of the damping ratio

This equation can be solved with the approach.

where C and s are both complex constants. That approach assumes a solution that is oscillatory and/or decaying exponentially. Using it in the ODE gives a condition on the frequency of the damped oscillations,

Undamped: Is the case where the solution looks like

corresponds to the undamped simple harmonic oscillator, and in that case , as expected.

Underdamped: If s is a complex number, then the solution is a decaying exponential combined with an oscillatory portion that looks like . This case occurs for , and is referred to as underdamped.

Damping ratio Overdamped: If s is a real number, then the solution is simply a decaying exponential with no oscillation. This case occurs for , and is referred to as overdamped. Critically damped:The case where is the border between the overdamped and underdamped cases, and is

referred to as critically damped. This turns out to be a desirable outcome in many cases where engineering design of a damped oscillator is required (e.g., a door closing mechanism).

Q factor and decay rate


The factors Q, damping ratio , and exponential decay rate are related such that[]

When a second-order system has

(that is, when the system is underdamped), it has two complex conjugate

poles that each have a real part of ; that is, the decay rate parameter represents the rate of exponential decay of the oscillations. A lower damping ratio implies a lower decay rate, and so very underdamped systems oscillate for long times.[2] For example, a high quality tuning fork, which has a very low damping ratio, has an oscillation that lasts a long time, decaying very slowly after being struck by a hammer.

Logarithmic decrement
The damping ratio is also related to the logarithmic decrement for underdamped vibrations via the relation

This relation is only meaningful for underdamped systems because the logarithmic decrement is defined as the natural log of the ratio of any two successive amplitudes, and only underdamped systems exhibit oscillation.

References

Article Sources and Contributors

Article Sources and Contributors


Damping ratio Source: http://en.wikipedia.org/w/index.php?oldid=549634874 Contributors: ASSami, AndrewDressel, Apoorvajsh, Barkman, BillC, Btyner, Cheeto81, ChrisGualtieri, Craigerv, Daniele.tampieri, Dannya222, Dicklyon, EdJogg, Gene Nygaard, Giftlite, HappyCamper, Jgreeter, MarSch, Michael Hardy, Nbarth, Nmnogueira, Oleg Alexandrov, PigFlu Oink, Remuel, Robobeg, Salsb, Sanpaz, Smit, SyntheticDNA, Teapeat, TedPavlic, Tlee123, Warut, Yeokaiwei, 53 anonymous edits

Image Sources, Licenses and Contributors


File:Damped spring.gif Source: http://en.wikipedia.org/w/index.php?title=File:Damped_spring.gif License: Public Domain Contributors: Oleg Alexandrov File:2nd Order Damping Ratios.svg Source: http://en.wikipedia.org/w/index.php?title=File:2nd_Order_Damping_Ratios.svg License: Public Domain Contributors: Inductiveload

License
Creative Commons Attribution-Share Alike 3.0 Unported //creativecommons.org/licenses/by-sa/3.0/

You might also like