AIR TERMINALS
FLAT TAPE SYSTEM Air Terminals and Fixings
Taper Pointed Air Rod
Can be installed with or without Multiple Point (below) Supplied with locknut.
Rod Length mm 500 1000 2000 500 1000 2000 Rod Dia. mm 15 15 15 15 15 15 Thread Dia. mm 16 16 16 16 16 16 Material Copper Copper Copper Aluminium Aluminium Aluminium Wgt. (kg.) per rod 0.73 1.51 3.0 0.29 0.53 1.06kg Cat. No. RA215 RA225 RA240 RA015 RA025 RA040
SOLID CIRCULAR SYSTEM Air Terminals & Fixings
Air Rod
Supplied with Lock Nut.
Wgt. (kg) per rod 0.33 0.65 0.11 Cat. No.
Rod Rod Thread Lengt Dia. Dia. Material h mm mm mm 500 10 10 Copper 1000 10 10 Copper 500 10 10 Aluminium
RA400 RA402 RA080
Air Terminal Base
Recommended fixingCounter Sunk Woodscrew 1 x no. 10 and wall plug.
Multiple Point
Conductor Thread Conductor Dia. Dia. Material mm mm Cat. No. RA600 8 8 10 10 Copper Aluminium Wgt. (kg) each 0.30 0.11 Cat. No. Vertically Horizontally mounted mounted SD307 SD007 SD305 SD005
06
For use with taper pointed air rods.
Rod Dia. mm 15 Material Copper Wgt. (kg.) per rod 0.27
Strike Pad
Air Terminal Base
Recommended fixing - Counter Sunk Woodscrew 1 x no. 10 and wall plug.
Rod Dia. mm 15 15 Thread Dia. mm 16 16 Maximum Conductor width mm 25 25 Wgt. (kg.) per rod 0.47 0.15 Cat. No. SD105 SD003
This product is supplied with a set screw to enable the lightning conductor to be attached to the strike pad.
Material Copper Aluminium Wgt. (kg) each 0.41 0.13 Wgt. (kg) each 0.07 Cat. No. PL010 PL005 Cat. No. SM010
Furseweld joint
Material Copper Aluminium
Accessories
Description Copper Stem for use with PL010
Ridge Saddle
The Strike Pad PL010 can be used in lightning protection schemes in multi-storey car-parks, using the stem SM010 connected to the re-bar cage or buried earth conductor.
CABLE & WIRE SYSTEM Air Terminals
Taper Pointed Air Rod
For supporting Lightning Conductor Air Terminals on ridge.
Rod Dia. mm 15 Thread Dia. mm 16 Maximum Conductor width mm 31
Recommended fixing- Counter Sunk Woodscrew 1 x no. 10 and wall plug.
Rod Material Copper Wgt. (kg.) per rod 1.07 Cat. No. SD115
Can be installed with or without Multiple Point (below) Supplied with locknut.
Rod Length mm 500 1000 2000 Rod Dia. mm 15 15 15 Thread Dia. mm 16 16 16 Material Copper Copper Copper Cat. No. RA215 RA225 RA240
Strike Pad
Multiple Point
For use with taper pointed air rods. This product is supplied with a set screw to enable the lightning conductor to be attached to the Strike
Rod Dia. mm 15 Material Copper Wgt. (kg.) per rod 0.27 Cat. No. RA600
Material Copper Aliminium
Wgt. (kg.) per rod 0.41 0.13 Wgt. (kg) each 0.07
Cat. No. PL010 PL005 Cat. No. SM010
Flat Saddle
Conductor 50 70 95 Rod 15 15 15
For supporting taper pointed air rods on flat surfaces.
Thread Dia. Material 16 16 16 Copper Copper Copper Cat. SD155 SD160 SD165
ACCESSORIES
Description Copper Stem for use with PL010
Recommended fixing Counter Sunk Woodscrew 1 x no. 10 and wall plug.
6-1