JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: service@jcinternationalng.com Website: www.jcinternationalng.com
CERTIFICATE OF VISUAL EXAMINATION
STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998
Certificate No. 7282 Identification Number Qty
Date of Examination 25/07/2012
Examiner OLATUNJI AKINLADE TARE WT SWL
Qualifications LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Description of Equipment
Examination
FABRICATED PADEYE
PE BOP 01
1
A Steel Construction Fabricated Pad Eye / Anchor Point
N/A
6 tonnes
N/A
N/A
24/01/13
LOCATION: BOP STAIRWAYS AREA PORT SIDE
SPECIFICATION: BS 2573 MPI METHOD: N/A PARTS EXAMINED: Entire body RESULTS: No defect as at the time of inspection. Fit for use TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A
Name and address of equipment owner: Pacific Drilling
Address of premises where test / Examination was held: Pacific Bora
We hereby certify that on 25/07/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection. Fit for use Signature of Inspector: Conducting Examination Name of Inspector: OLATUNJI AKINLADE Conducting: Examination only
Revision No: 01
Doc No: JCI-C-V-01
JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: service@jcinternationalng.com Website: www.jcinternationalng.com
CERTIFICATE OF VISUAL EXAMINATION
STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998
Certificate No. 7283 Identification Number Qty
Date of Examination 25/07/2012
Examiner OLATUNJI AKINLADE TARE WT SWL
Qualifications LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Description of Equipment
Examination
FABRICATED PADEYE
PE BOP 02
1
A Steel Construction Fabricated Pad Eye / Anchor Point
N/A
6 tonnes
N/A
N/A
24/01/13
LOCATION: BOP STAIRWAYS AREA PORT SIDE
SPECIFICATION: BS 2573 MPI METHOD: N/A PARTS EXAMINED: Entire body RESULTS: No defect as at the time of inspection. Fit for use TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A
Name and address of equipment owner : Pacific Drilling
Address of premises where test / Examination was held: Pacific Bora
We hereby certify that on 25/07/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection. Fit for use Signature of Inspector: Conducting Examination Name of Inspector: OLATUNJI AKINLADE Conducting: Examination only
Revision No: 01
Doc No: JCI-C-V-01
JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: service@jcinternationalng.com Website: www.jcinternationalng.com
CERTIFICATE OF VISUAL EXAMINATION
STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998
Certificate No. 7284 Identification Number Qty
Date of Examination 25/07/2012
Examiner OLATUNJI AKINLADE TARE WT SWL
Qualifications LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Description of Equipment
Examination
FABRICATED PADEYE
PE BOP 01A
1
A Steel Construction Fabricated Pad Eye / Anchor Point
N/A
3 tonnes
N/A
N/A
24/01/13
LOCATION: BOP STAIRWAYS AREA PORT SIDE
SPECIFICATION: BS 2573 MPI METHOD: N/A PARTS EXAMINED: Entire body RESULTS: No defect as at the time of inspection. Fit for use TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A
Name and address of equipment owner : Pacific Drilling
Address of premises where test / Examination was held: Pacific Bora
We hereby certify that on 25/07/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection. Fit for use Signature of Inspector: Conducting Examination Name of Inspector: OLATUNJI AKINLADE Conducting: Examination only
Revision No: 01
Doc No: JCI-C-V-01
JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: service@jcinternationalng.com Website: www.jcinternationalng.com
CERTIFICATE OF VISUAL EXAMINATION
STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998
Certificate No. 7285 Identification Number Qty
Date of Examination 25/07/2012
Examiner OLATUNJI AKINLADE TARE WT SWL
Qualifications LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Description of Equipment
Examination
FABRICATED PADEYE
PE BOP 01B
1
A Steel Construction Fabricated Pad Eye / Anchor Point
N/A
3 tonnes
N/A
N/A
24/01/13
LOCATION: BOP STAIRWAYS AREA PORT SIDE
SPECIFICATION: BS 2573 MPI METHOD: N/A PARTS EXAMINED: Entire body RESULTS: No defect as at the time of inspection. Fit for use TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A
Name and address of equipment owner : Pacific Drilling
Address of premises where test / Examination was held: Pacific Bora
We hereby certify that on 25/07/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection. Fit for use Signature of Inspector: Conducting Examination Name of Inspector: OLATUNJI AKINLADE Conducting: Examination only
Revision No: 01
Doc No: JCI-C-V-01
JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: service@jcinternationalng.com Website: www.jcinternationalng.com
CERTIFICATE OF TEST , EXAMINATION AND MPI
STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998
Certificate No. 7286
Date of Examination 25/07/2012
Examiner OLATUNJI AKINLADE
Qualifications LEEA, SNT LEVEL II MT, PT & UT
Identification Number
Description of Equipment PADEYE
050
Swivel Bolted Pad Eye SWL: 10 tonnes Proof Load Applied: 15 tonnes
Date of Next Examination: 24-01-13
LOCATION: BOP AREA STBD SIDE
SPECIFICATION: BS 2573 MPI METHOD: Wet Visible PARTS EXAMINED: Entire body RESULTS: No defect as at the time of inspection. Fit for use TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-050 White Contrast Aid Black Magnetic Ink
Name and address of equipment owner : Pacific Drilling
Address of premises where test / Examination was held: Pacific Bora
We hereby certify that on 25/07/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection. Fit for use Signature of Inspector: Conducting Examination Name of Inspector: OLATUNJI AKINLADE Conducting: Test & Examination only
Revision No: 01
Doc No: JCI-C-MPIT-01
JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: service@jcinternationalng.com Website: www.jcinternationalng.com
CERTIFICATE OF TEST, EXAMINATION AND MPI
STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998
Certificate No. 7287
Date of Examination 25/07/2012
Examiner OLATUNJI AKINLADE
Qualifications LEEA, SNT LEVEL II MT, PT & UT
Identification Number
Description of Equipment PADEYE
051
Swivel Bolted Pad Eye SWL: 10 tonnes Proof Load Applied: 15 tonnes
Date of Next Examination: 24-01-13
LOCATION: BOP AREA STBD SIDE
SPECIFICATION: BS 2573 MPI METHOD: Wet Visible PARTS EXAMINED: Entire body RESULTS: No defect as at the time of inspection. Fit for use TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-050 White Contrast Aid Black Magnetic Ink
Name and address of equipment owner : Pacific Drilling
Address of premises where test / Examination was held: Pacific Bora
We hereby certify that on 25/07/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection. Fit for use Signature of Inspector: Conducting Examination Name of Inspector: OLATUNJI AKINLADE Conducting: Test & Examination only
Revision No: 01
Doc No: JCI-C-MPIT-01
JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: service@jcinternationalng.com Website: www.jcinternationalng.com
CERTIFICATE OF TEST , EXAMINATION AND MPI
STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998
Certificate No. 7288
Date of Examination 26/07/2012
Examiner OLATUNJI AKINLADE
Qualifications LEEA, SNT LEVEL II MT, PT & UT
Identification Number
Description of Equipment
FABRICATED PADEYE
052
A Steel Construction Fabricated Pad Eye / Anchor Point
SWL: 1 tonne Proof Load Applied: 1.5 tonnes
Date of Next Examination: 25-01-13
LOCATION: BOP STAIRWAYS AREA STBD SIDE
SPECIFICATION: BS 2573 MPI METHOD: Wet Visible PARTS EXAMINED: Entire body RESULTS: No defect as at the time of inspection. Fit for use TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-050 White Contrast Aid Black Magnetic Ink
Name and address of equipment owner : Pacific Drilling
Address of premises where test / Examination was held: Pacific Bora
We hereby certify that on 26/07/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection. Fit for use Signature of Inspector: Conducting Examination Name of Inspector: OLATUNJI AKINLADE Conducting: Test & Examination only
Revision No: 01
Doc No: JCI-C-MPIT-01
JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: service@jcinternationalng.com Website: www.jcinternationalng.com
CERTIFICATE OF TEST, EXAMINATION AND MPI
STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998
Certificate No. 7289
Date of Examination 26/07/2012
Examiner OLATUNJI AKINLADE
Qualifications LEEA, SNT LEVEL II MT, PT & UT
Identification Number
Description of Equipment
FABRICATED PADEYE
054
A Steel Construction Fabricated Pad Eye / Anchor Point
SWL: 500kg Proof Load Applied: 750kg
Date of Next Examination: 25-01-13
LOCATION: BOP AREA STBD SIDE
SPECIFICATION: BS 2573 MPI METHOD: Wet Visible PARTS EXAMINED: Entire body RESULTS: No defect as at the time of inspection. Fit for use TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-050 White Contrast Aid Black Magnetic Ink
Name and address of equipment owner : Pacific Drilling
Address of premises where test / Examination was held: Pacific Bora
We hereby certify that on 26/07/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection. Fit for use Signature of Inspector: Conducting Examination Name of Inspector: OLATUNJI AKINLADE Conducting: Test & Examination only
Revision No: 01
Doc No: JCI-C-MPIT-01
JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: service@jcinternationalng.com Website: www.jcinternationalng.com
CERTIFICATE OF TEST, EXAMINATION AND MPI
STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998
Certificate No. 7290 Identification Number
Date of Examination
Examiner
Qualifications LEEA, SNT LEVEL II MT, PT & UT GROSS Proof Date of WT Load next Examination Applied
Qty
26/07/2012 OLATUNJI AKINLADE Description of Equipment TARE SWL WT
FABRICATED PADEYE
055
1
A Steel Construction Fabricated Pad Eye / Anchor Point
N/A
1 tonne
N/A
1.5 tonnes
25/01/13
LOCATION: BOP STAIRWAYS AREA STBD SIDE
SPECIFICATION: BS 2573 MPI METHOD: Wet Visible PARTS EXAMINED: Entire body RESULTS: No defect as at the time of inspection. Fit for use TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-050 White Contrast Aid Black Magnetic Ink
Name and address of equipment owner : Pacific Drilling
Address of premises where test / Examination was held: Pacific Bora
We hereby certify that on 26/07/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection. Fit for use Signature of Inspector: Conducting Examination Name of Inspector: OLATUNJI AKINLADE Conducting: Test & Examination only
Revision No: 01
Doc No: JCI-C-MPIT-01
JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: service@jcinternationalng.com Website: www.jcinternationalng.com
CERTIFICATE OF TEST, EXAMINATION AND MPI
STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998
Certificate No. 7291
Date of Examination 26/07/2012
Examiner OLATUNJI AKINLADE
Qualifications LEEA, SNT LEVEL II MT, PT & UT
Identification Number
Description of Equipment
FABRICATED PADEYE
056
A Steel Construction Fabricated Pad Eye / Anchor Point
SWL: 1 tonne Proof Load Applied: 1.5 tonnes
Date of Next Examination: 25-01-13
LOCATION: BOP STAIRWAYS AREA STBD SIDE
SPECIFICATION: BS 2573 MPI METHOD: Wet Visible PARTS EXAMINED: Entire body RESULTS: No defect as at the time of inspection. Fit for use TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-050 White Contrast Aid Black Magnetic Ink
Name and address of equipment owner : Pacific Drilling
Address of premises where test / Examination was held: Pacific Bora
We hereby certify that on 26/07/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection. Fit for use Signature of Inspector: Conducting Examination Name of Inspector: OLATUNJI AKINLADE Conducting: Test & Examination only
Revision No: 01
Doc No: JCI-C-MPIT-01
JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: service@jcinternationalng.com Website: www.jcinternationalng.com
CERTIFICATE OF TEST, EXAMINATION AND MPI
STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998
Certificate No. 7292
Date of Examination 26/07/2012
Examiner OLATUNJI AKINLADE
Qualifications LEEA, SNT LEVEL II MT, PT & UT
Identification Number
Description of Equipment
FABRICATED PADEYE
057
A Steel Construction Fabricated Pad Eye / Anchor Point
SWL: 1 tonne Proof Load Applied: 1.5 tonnes
Date of Next Examination: 25-01-13
LOCATION: BOP STAIRWAYS AREA STBD SIDE
SPECIFICATION: BS 2573 MPI METHOD: Wet Visible PARTS EXAMINED: Entire body RESULTS: No defect as at the time of inspection. Fit for use TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-050 White Contrast Aid Black Magnetic Ink
Name and address of equipment owner : Pacific Drilling
Address of premises where test / Examination was held: Pacific Bora
We hereby certify that on 26/07/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection. Fit for use Signature of Inspector: Conducting Examination Name of Inspector: OLATUNJI AKINLADE Conducting: Test & Examination only
Revision No: 01
Doc No: JCI-C-MPIT-01
JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: service@jcinternationalng.com Website: www.jcinternationalng.com
CERTIFICATE OF TEST, EXAMINATION AND MPI
STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998
Certificate No. 7293
Date of Examination 26/07/2012
Examiner OLATUNJI AKINLADE
Qualifications LEEA, SNT LEVEL II MT, PT & UT
Identification Number
Description of Equipment
FABRICATED PADEYE
058
A Steel Construction Fabricated Pad Eye / Anchor Point
SWL: 1 tonne Proof Load Applied: 1.5 tonnes
Date of Next Examination: 25-01-13
LOCATION: BOP STAIRWAYS AREA STBD SIDE
SPECIFICATION: BS 2573 MPI METHOD: Wet Visible PARTS EXAMINED: Entire body RESULTS: No defect as at the time of inspection. Fit for use TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-050 White Contrast Aid Black Magnetic Ink
Name and address of equipment owner: Pacific Drilling
Address of premises where test / Examination was held: Pacific Bora
We hereby certify that on 26/07/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection. Fit for use Signature of Inspector: Conducting Examination Name of Inspector: OLATUNJI AKINLADE Conducting: Test & Examination only
Revision No: 01
Doc No: JCI-C-MPIT-01
JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: service@jcinternationalng.com Website: www.jcinternationalng.com
CERTIFICATE OF TEST, EXAMINATION AND MPI
STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998
Certificate No. 7294
Date of Examination 26/07/2012
Examiner OLATUNJI AKINLADE
Qualifications LEEA, SNT LEVEL II MT, PT & UT
Identification Number
Description of Equipment
FABRICATED PADEYE
059
A Steel Construction Fabricated Pad Eye / Anchor Point
SWL: 1 tonne Proof Load Applied: 1.5 tonnes
Date of Next Examination: 25-01-13
LOCATION: BOP STAIRWAYS AREA STBD SIDE
SPECIFICATION: BS 2573 MPI METHOD: Wet Visible PARTS EXAMINED: Entire body RESULTS: No defect as at the time of inspection. Fit for use TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-050 White Contrast Aid Black Magnetic Ink
Name and address of equipment owner : Pacific Drilling
Address of premises where test / Examination was held: Pacific Bora
We hereby certify that on 26/07/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection. Fit for use Signature of Inspector: Conducting Examination Name of Inspector: OLATUNJI AKINLADE Conducting: Test & Examination only
Revision No: 01
Doc No: JCI-C-MPIT-01
JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: service@jcinternationalng.com Website: www.jcinternationalng.com
CERTIFICATE OF TEST, EXAMINATION AND MPI
STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998
Certificate No. 7295
Date of Examination 26/07/2012
Examiner OLATUNJI AKINLADE
Qualifications LEEA, SNT LEVEL II MT, PT & UT
Identification Number
Description of Equipment
FABRICATED PADEYE
060
A Steel Construction Fabricated Pad Eye / Anchor Point
SWL: 500kg Proof Load Applied: 750kg
Date of Next Examination: 25-01-13
LOCATION: BOP AREA PORT SIDE
SPECIFICATION: BS 2573 MPI METHOD: Wet Visible PARTS EXAMINED: Entire body RESULTS: No defect as at the time of inspection. Fit for use TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-050 White Contrast Aid Black Magnetic Ink
Name and address of equipment owner : Pacific Drilling
Address of premises where test / Examination was held: Pacific Bora
We hereby certify that on 26/07/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection. Fit for use Signature of Inspector: Conducting Examination Name of Inspector: OLATUNJI AKINLADE Conducting: Test & Examination only
Revision No: 01
Doc No: JCI-C-MPIT-01
JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: service@jcinternationalng.com Website: www.jcinternationalng.com
CERTIFICATE OF TEST, EXAMINATION AND MPI
STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998
Certificate No. 7296
Date of Examination 26/07/2012
Examiner OLATUNJI AKINLADE
Qualifications LEEA, SNT LEVEL II MT, PT & UT
Identification Number
Description of Equipment PADEYE
061
Swivel Bolted Pad Eye SWL: 10 tonnes Proof Load Applied: 15 tonnes
Date of Next Examination: 25-01-13
LOCATION: BOP AREA STBD SIDE
SPECIFICATION: BS 2573 MPI METHOD: Wet Visible PARTS EXAMINED: Entire body RESULTS: No defect as at the time of inspection. Fit for use TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-050 White Contrast Aid Black Magnetic Ink
Name and address of equipment owner : Pacific Drilling
Address of premises where test / Examination was held: Pacific Bora
We hereby certify that on 26/07/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection. Fit for use Signature of Inspector: Conducting Examination Name of Inspector: OLATUNJI AKINLADE Conducting: Test & Examination only
Revision No: 01
Doc No: JCI-C-MPIT-01
JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: service@jcinternationalng.com Website: www.jcinternationalng.com
CERTIFICATE OF VISUAL EXAMINATION
STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998
Certificate No. 7297 Identification Number Qty
Date of Examination 27/07/2012
Examiner OLATUNJI AKINLADE TARE WT SWL
Qualifications LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Description of Equipment
Examination
FABRICATED PADEYE
LL 28-B
1
A Steel Construction Fabricated Pad Eye / Anchor Point
N/A
12 tonnes
N/A
N/A
26/01/13
LOCATION: DERRICK
SPECIFICATION: BS 2573 MPI METHOD: N/A PARTS EXAMINED: Entire body RESULTS: No defect as at the time of inspection. Fit for use TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A
Name and address of equipment owner : Pacific Drilling
Address of premises where test / Examination was held: Pacific Bora
We hereby certify that on 27/07/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection. Fit for use Signature of Inspector: Conducting Examination Name of Inspector: OLATUNJI AKINLADE Conducting: Examination only
Revision No: 01
Doc No: JCI-C-V-01
JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: service@jcinternationalng.com Website: www.jcinternationalng.com
CERTIFICATE OF VISUAL EXAMINATION
STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998
Certificate No. 7298 Identification Number Qty
Date of Examination 27/07/2012
Examiner OLATUNJI AKINLADE TARE WT SWL
Qualifications LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Description of Equipment
Examination
FABRICATED PADEYE
LL 29-D
1
A Steel Construction Fabricated Pad Eye / Anchor Point
N/A
85 tonnes
N/A
N/A
26/01/13
LOCATION: DERRICK
SPECIFICATION: BS 2573 MPI METHOD: N/A PARTS EXAMINED: Entire body RESULTS: No defect as at the time of inspection. Fit for use TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A
Name and address of equipment owner : Pacific Drilling
Address of premises where test / Examination was held: Pacific Bora
We hereby certify that on 27/07/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection. Fit for use Signature of Inspector: Conducting Examination Name of Inspector: OLATUNJI AKINLADE Conducting: Examination only
Revision No: 01
Doc No: JCI-C-V-01
JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: service@jcinternationalng.com Website: www.jcinternationalng.com
CERTIFICATE OF VISUAL EXAMINATION
STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998
Certificate No. 7299 Identification Number Qty
Date of Examination 27/07/2012
Examiner OLATUNJI AKINLADE TARE WT SWL
Qualifications LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Description of Equipment
Examination
FABRICATED PADEYE
LL 27-A
1
A Steel Construction Fabricated Pad Eye / Anchor Point
N/A
12 tonnes
N/A
N/A
26/01/13
LOCATION: DERRICK
SPECIFICATION: BS 2573 MPI METHOD: N/A PARTS EXAMINED: Entire body RESULTS: No defect as at the time of inspection. Fit for use TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A
Name and address of equipment owner : Pacific Drilling
Address of premises where test / Examination was held: Pacific Bora
We hereby certify that on 27/07/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection. Fit for use Signature of Inspector: Conducting Examination Name of Inspector: OLATUNJI AKINLADE Conducting: Examination only
Revision No: 01
Doc No: JCI-C-V-01
JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: service@jcinternationalng.com Website: www.jcinternationalng.com
CERTIFICATE OF VISUAL EXAMINATION
STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998
Certificate No. 7300 Identification Number Qty
Date of Examination 27/07/2012
Examiner OLATUNJI AKINLADE TARE WT SWL
Qualifications LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Description of Equipment
Examination
FABRICATED PADEYE
LL 27-B
1
A Steel Construction Fabricated Pad Eye / Anchor Point
N/A
12 tonnes
N/A
N/A
26/01/13
LOCATION: DERRICK
SPECIFICATION: BS 2573 MPI METHOD: N/A PARTS EXAMINED: Entire body RESULTS: No defect as at the time of inspection. Fit for use TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A
Name and address of equipment owner : Pacific Drilling
Address of premises where test / Examination was held: Pacific Bora
We hereby certify that on 27/07/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection. Fit for use Signature of Inspector: Conducting Examination Name of Inspector: OLATUNJI AKINLADE Conducting: Examination only
Revision No: 01
Doc No: JCI-C-V-01
JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: service@jcinternationalng.com Website: www.jcinternationalng.com
CERTIFICATE OF VISUAL EXAMINATION
STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998
Certificate No. 7301 Identification Number Qty
Date of Examination 27/07/2012
Examiner OLATUNJI AKINLADE TARE WT SWL
Qualifications LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Description of Equipment
Examination
FABRICATED PADEYE
LL 29-A
1
A Steel Construction Fabricated Pad Eye / Anchor Point
N/A
85 tonnes
N/A
N/A
26/01/13
LOCATION: DERRICK
SPECIFICATION: BS 2573 MPI METHOD: N/A PARTS EXAMINED: Entire body RESULTS: No defect as at the time of inspection. Fit for use TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A
Name and address of equipment owner : Pacific Drilling
Address of premises where test / Examination was held: Pacific Bora
We hereby certify that on 27/07/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection. Fit for use Signature of Inspector: Conducting Examination Name of Inspector: OLATUNJI AKINLADE Conducting: Examination only
Revision No: 01
Doc No: JCI-C-V-01
JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: service@jcinternationalng.com Website: www.jcinternationalng.com
CERTIFICATE OF VISUAL EXAMINATION
STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998
Certificate No. 7302 Identification Number Qty
Date of Examination 27/07/2012
Examiner OLATUNJI AKINLADE TARE WT SWL
Qualifications LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Description of Equipment
Examination
FABRICATED PADEYE
LL 25-B
1
A Steel Construction Fabricated Pad Eye / Anchor Point
N/A
85 tonnes
N/A
N/A
26/01/13
LOCATION: DERRICK
SPECIFICATION: BS 2573 MPI METHOD: N/A PARTS EXAMINED: Entire body RESULTS: No defect as at the time of inspection. Fit for use TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A
Name and address of equipment owner : Pacific Drilling
Address of premises where test / Examination was held: Pacific Bora
We hereby certify that on 27/07/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection. Fit for use Signature of Inspector: Conducting Examination Name of Inspector: OLATUNJI AKINLADE Conducting: Examination only
Revision No: 01
Doc No: JCI-C-V-01
JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: service@jcinternationalng.com Website: www.jcinternationalng.com
CERTIFICATE OF VISUAL EXAMINATION
STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998
Certificate No. 7303 Identification Number Qty
Date of Examination 27/07/2012
Examiner OLATUNJI AKINLADE TARE WT SWL
Qualifications LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Description of Equipment
Examination
FABRICATED PADEYE
LL 29-B
1
A Steel Construction Fabricated Pad Eye / Anchor Point
N/A
85 tonnes
N/A
N/A
26/01/13
LOCATION: DERRICK
SPECIFICATION: BS 2573 MPI METHOD: N/A PARTS EXAMINED: Entire body RESULTS: No defect as at the time of inspection. Fit for use TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A
Name and address of equipment owner : Pacific Drilling
Address of premises where test / Examination was held: Pacific Bora
We hereby certify that on 27/07/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection. Fit for use Signature of Inspector: Conducting Examination Name of Inspector: OLATUNJI AKINLADE Conducting: Examination only
Revision No: 01
Doc No: JCI-C-V-01
JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: service@jcinternationalng.com Website: www.jcinternationalng.com
CERTIFICATE OF VISUAL EXAMINATION
STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998
Certificate No. 7304 Identification Number Qty
Date of Examination 27/07/2012
Examiner OLATUNJI AKINLADE TARE WT SWL
Qualifications LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Description of Equipment
Examination
FABRICATED PADEYE
LL 28-A
1
A Steel Construction Fabricated Pad Eye / Anchor Point
N/A
12 tonnes
N/A
N/A
26/01/13
LOCATION: DERRICK
SPECIFICATION: BS 2573 MPI METHOD: N/A PARTS EXAMINED: Entire body RESULTS: No defect as at the time of inspection. Fit for use TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A
Name and address of equipment owner : Pacific Drilling
Address of premises where test / Examination was held: Pacific Bora
We hereby certify that on 27/07/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection. Fit for use Signature of Inspector: Conducting Examination Name of Inspector: OLATUNJI AKINLADE Conducting: Examination only
Revision No: 01
Doc No: JCI-C-V-01
JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: service@jcinternationalng.com Website: www.jcinternationalng.com
CERTIFICATE OF VISUAL EXAMINATION
STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998
Certificate No. 7305 Identification Number Qty
Date of Examination 27/07/2012
Examiner OLATUNJI AKINLADE TARE WT SWL
Qualifications LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Description of Equipment
Examination
FABRICATED PADEYE
LL 27-C
1
A Steel Construction Fabricated Pad Eye / Anchor Point
N/A
12 tonnes
N/A
N/A
26/01/13
LOCATION: DERRICK
SPECIFICATION: BS 2573 MPI METHOD: N/A PARTS EXAMINED: Entire body RESULTS: No defect as at the time of inspection. Fit for use TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A
Name and address of equipment owner : Pacific Drilling
Address of premises where test / Examination was held: Pacific Bora
We hereby certify that on 27/07/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection. Fit for use Signature of Inspector: Conducting Examination Name of Inspector: OLATUNJI AKINLADE Conducting: Examination only
Revision No: 01
Doc No: JCI-C-V-01
JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: service@jcinternationalng.com Website: www.jcinternationalng.com
CERTIFICATE OF VISUAL EXAMINATION
STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998
Certificate No. 7306 Identification Number Qty
Date of Examination 27/07/2012
Examiner OLATUNJI AKINLADE TARE WT SWL
Qualifications LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Description of Equipment
Examination
FABRICATED PADEYE
LL 27-D
1
A Steel Construction Fabricated Pad Eye / Anchor Point
N/A
12 tonnes
N/A
N/A
26/01/13
LOCATION: DERRICK
SPECIFICATION: BS 2573 MPI METHOD: N/A PARTS EXAMINED: Entire body RESULTS: No defect as at the time of inspection. Fit for use TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A
Name and address of equipment owner : Pacific Drilling
Address of premises where test / Examination was held: Pacific Bora
We hereby certify that on 27/07/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection. Fit for use Signature of Inspector: Conducting Examination Name of Inspector: OLATUNJI AKINLADE Conducting: Examination only
Revision No: 01
Doc No: JCI-C-V-01
JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: service@jcinternationalng.com Website: www.jcinternationalng.com
CERTIFICATE OF VISUAL EXAMINATION
STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998
Certificate No. 7307 Identification Number Qty
Date of Examination 27/07/2012
Examiner OLATUNJI AKINLADE TARE WT SWL
Qualifications LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Description of Equipment
Examination
FABRICATED PADEYE
LL 27-E
1
A Steel Construction Fabricated Pad Eye / Anchor Point
N/A
12 tonnes
N/A
N/A
26/01/13
LOCATION: DERRICK
SPECIFICATION: BS 2573 MPI METHOD: N/A PARTS EXAMINED: Entire body RESULTS: No defect as at the time of inspection. Fit for use TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A
Name and address of equipment owner : Pacific Drilling
Address of premises where test / Examination was held: Pacific Bora
We hereby certify that on 27/07/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection. Fit for use Signature of Inspector: Conducting Examination Name of Inspector: OLATUNJI AKINLADE Conducting: Examination only
Revision No: 01
Doc No: JCI-C-V-01
JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: service@jcinternationalng.com Website: www.jcinternationalng.com
CERTIFICATE OF VISUAL EXAMINATION
STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998
Certificate No. 7308 Identification Number Qty
Date of Examination 27/07/2012
Examiner OLATUNJI AKINLADE TARE WT SWL
Qualifications LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Description of Equipment
Examination
FABRICATED PADEYE
LL 27-F
1
A Steel Construction Fabricated Pad Eye / Anchor Point
N/A
12 tonnes
N/A
N/A
26/01/13
LOCATION: DERRICK
SPECIFICATION: BS 2573 MPI METHOD: N/A PARTS EXAMINED: Entire body RESULTS: No defect as at the time of inspection. Fit for use TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A
Name and address of equipment owner : Pacific Drilling
Address of premises where test / Examination was held: Pacific Bora
We hereby certify that on 27/07/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection. Fit for use Signature of Inspector: Conducting Examination Name of Inspector: OLATUNJI AKINLADE Conducting: Examination only
Revision No: 01
Doc No: JCI-C-V-01
JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: service@jcinternationalng.com Website: www.jcinternationalng.com
CERTIFICATE OF VISUAL EXAMINATION
STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998
Certificate No. 7309 Identification Number Qty
Date of Examination 27/07/2012
Examiner OLATUNJI AKINLADE TARE WT SWL
Qualifications LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Description of Equipment
Examination
FABRICATED PADEYE
LL 25-A
1
A Steel Construction Fabricated Pad Eye / Anchor Point
N/A
85 tonnes
N/A
N/A
26/01/13
LOCATION: DERRICK
SPECIFICATION: BS 2573 MPI METHOD: N/A PARTS EXAMINED: Entire body RESULTS: No defect as at the time of inspection. Fit for use TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A
Name and address of equipment owner : Pacific Drilling
Address of premises where test / Examination was held: Pacific Bora
We hereby certify that on 27/07/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection. Fit for use Signature of Inspector: Conducting Examination Name of Inspector: OLATUNJI AKINLADE Conducting: Examination only
Revision No: 01
Doc No: JCI-C-V-01
JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: service@jcinternationalng.com Website: www.jcinternationalng.com
CERTIFICATE OF VISUAL EXAMINATION
STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998
Certificate No. 7310 Identification Number Qty
Date of Examination 27/07/2012
Examiner OLATUNJI AKINLADE TARE WT SWL
Qualifications LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Description of Equipment
Examination
FABRICATED PADEYE
LL 8-B
1
A Steel Construction Fabricated Pad Eye / Anchor Point
N/A
12 tonnes
N/A
N/A
26/01/13
LOCATION: DERRICK
SPECIFICATION: BS 2573 MPI METHOD: N/A PARTS EXAMINED: Entire body RESULTS: No defect as at the time of inspection. Fit for use TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A
Name and address of equipment owner : Pacific Drilling
Address of premises where test / Examination was held: Pacific Bora
We hereby certify that on 27/07/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection. Fit for use Signature of Inspector: Conducting Examination Name of Inspector: OLATUNJI AKINLADE Conducting: Examination only
Revision No: 01
Doc No: JCI-C-V-01
JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: service@jcinternationalng.com Website: www.jcinternationalng.com
CERTIFICATE OF VISUAL EXAMINATION
STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998
Certificate No. 7311 Identification Number Qty
Date of Examination 27/07/2012
Examiner OLATUNJI AKINLADE TARE WT SWL
Qualifications LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Description of Equipment
Examination
FABRICATED PADEYE
LL 9-D
1
A Steel Construction Fabricated Pad Eye / Anchor Point
N/A
85 tonnes
N/A
N/A
26/01/13
LOCATION: DERRICK
SPECIFICATION: BS 2573 MPI METHOD: N/A PARTS EXAMINED: Entire body RESULTS: No defect as at the time of inspection. Fit for use TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A
Name and address of equipment owner : Pacific Drilling
Address of premises where test / Examination was held: Pacific Bora
We hereby certify that on 27/07/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection. Fit for use Signature of Inspector: Conducting Examination Name of Inspector: OLATUNJI AKINLADE Conducting: Examination only
Revision No: 01
Doc No: JCI-C-V-01
JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: service@jcinternationalng.com Website: www.jcinternationalng.com
CERTIFICATE OF VISUAL EXAMINATION
STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998
Certificate No. 7312 Identification Number Qty
Date of Examination 27/07/2012
Examiner OLATUNJI AKINLADE TARE WT SWL
Qualifications LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Description of Equipment
Examination
FABRICATED PADEYE
LL 5-A
1
A Steel Construction Fabricated Pad Eye / Anchor Point
N/A
85 tonnes
N/A
N/A
26/01/13
LOCATION: DERRICK
SPECIFICATION: BS 2573 MPI METHOD: N/A PARTS EXAMINED: Entire body RESULTS: No defect as at the time of inspection. Fit for use TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A
Name and address of equipment owner : Pacific Drilling
Address of premises where test / Examination was held: Pacific Bora
We hereby certify that on 27/07/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection. Fit for use Signature of Inspector: Conducting Examination Name of Inspector: OLATUNJI AKINLADE Conducting: Examination only
Revision No: 01
Doc No: JCI-C-V-01
JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: service@jcinternationalng.com Website: www.jcinternationalng.com
CERTIFICATE OF VISUAL EXAMINATION
STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998
Certificate No. 7313 Identification Number Qty
Date of Examination 27/07/2012
Examiner OLATUNJI AKINLADE TARE WT SWL
Qualifications LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Description of Equipment
Examination
FABRICATED PADEYE
LL 7-A
1
A Steel Construction Fabricated Pad Eye / Anchor Point
N/A
12 tonnes
N/A
N/A
26/01/13
LOCATION: DERRICK
SPECIFICATION: BS 2573 MPI METHOD: N/A PARTS EXAMINED: Entire body RESULTS: No defect as at the time of inspection. Fit for use TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A
Name and address of equipment owner : Pacific Drilling
Address of premises where test / Examination was held: Pacific Bora
We hereby certify that on 27/07/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection. Fit for use Signature of Inspector: Conducting Examination Name of Inspector: OLATUNJI AKINLADE Conducting: Examination only
Revision No: 01
Doc No: JCI-C-V-01
JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: service@jcinternationalng.com Website: www.jcinternationalng.com
CERTIFICATE OF VISUAL EXAMINATION
STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998
Certificate No. 7314 Identification Number Qty
Date of Examination 27/07/2012
Examiner OLATUNJI AKINLADE TARE WT SWL
Qualifications LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Description of Equipment
Examination
FABRICATED PADEYE
LL 7-B
1
A Steel Construction Fabricated Pad Eye / Anchor Point
N/A
12 tonnes
N/A
N/A
26/01/13
LOCATION: DERRICK
SPECIFICATION: BS 2573 MPI METHOD: N/A PARTS EXAMINED: Entire body RESULTS: No defect as at the time of inspection. Fit for use TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A
Name and address of equipment owner : Pacific Drilling
Address of premises where test / Examination was held: Pacific Bora
We hereby certify that on 27/07/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection. Fit for use Signature of Inspector: Conducting Examination Name of Inspector: OLATUNJI AKINLADE Conducting: Examination only
Revision No: 01
Doc No: JCI-C-V-01
JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: service@jcinternationalng.com Website: www.jcinternationalng.com
CERTIFICATE OF VISUAL EXAMINATION
STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998
Certificate No. 7315 Identification Number Qty
Date of Examination 27/07/2012
Examiner OLATUNJI AKINLADE TARE WT SWL
Qualifications LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Description of Equipment
Examination
FABRICATED PADEYE
LL 5-B
1
A Steel Construction Fabricated Pad Eye / Anchor Point
N/A
85 tonnes
N/A
N/A
26/01/13
LOCATION: DERRICK
SPECIFICATION: BS 2573 MPI METHOD: N/A PARTS EXAMINED: Entire body RESULTS: No defect as at the time of inspection. Fit for use TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A
Name and address of equipment owner : Pacific Drilling
Address of premises where test / Examination was held: Pacific Bora
We hereby certify that on 27/07/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection. Fit for use Signature of Inspector: Conducting Examination Name of Inspector: OLATUNJI AKINLADE Conducting: Examination only
Revision No: 01
Doc No: JCI-C-V-01
JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: service@jcinternationalng.com Website: www.jcinternationalng.com
CERTIFICATE OF VISUAL EXAMINATION
STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998
Certificate No. 7316 Identification Number Qty
Date of Examination 27/07/2012
Examiner OLATUNJI AKINLADE TARE WT SWL
Qualifications LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Description of Equipment
Examination
FABRICATED PADEYE
LL 9-A
1
A Steel Construction Fabricated Pad Eye / Anchor Point
N/A
85 tonnes
N/A
N/A
26/01/13
LOCATION: DERRICK
SPECIFICATION: BS 2573 MPI METHOD: N/A PARTS EXAMINED: Entire body RESULTS: No defect as at the time of inspection. Fit for use TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A
Name and address of equipment owner : Pacific Drilling
Address of premises where test / Examination was held: Pacific Bora
We hereby certify that on 27/07/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection. Fit for use Signature of Inspector: Conducting Examination Name of Inspector: OLATUNJI AKINLADE Conducting: Examination only
Revision No: 01
Doc No: JCI-C-V-01
JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: service@jcinternationalng.com Website: www.jcinternationalng.com
CERTIFICATE OF VISUAL EXAMINATION
STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998
Certificate No. 7317 Identification Number Qty
Date of Examination 27/07/2012
Examiner OLATUNJI AKINLADE TARE WT SWL
Qualifications LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Description of Equipment
Examination
FABRICATED PADEYE
LL 7-F
1
A Steel Construction Fabricated Pad Eye / Anchor Point
N/A
12 tonnes
N/A
N/A
26/01/13
LOCATION: DERRICK
SPECIFICATION: BS 2573 MPI METHOD: N/A PARTS EXAMINED: Entire body RESULTS: No defect as at the time of inspection. Fit for use TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A
Name and address of equipment owner : Pacific Drilling
Address of premises where test / Examination was held: Pacific Bora
We hereby certify that on 27/07/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection. Fit for use Signature of Inspector: Conducting Examination Name of Inspector: OLATUNJI AKINLADE Conducting: Examination only
Revision No: 01
Doc No: JCI-C-V-01
JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: service@jcinternationalng.com Website: www.jcinternationalng.com
CERTIFICATE OF VISUAL EXAMINATION
STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998
Certificate No. 7318 Identification Number Qty
Date of Examination 27/07/2012
Examiner OLATUNJI AKINLADE TARE WT SWL
Qualifications LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Description of Equipment
Examination
FABRICATED PADEYE
LL 7-E
1
A Steel Construction Fabricated Pad Eye / Anchor Point
N/A
12 tonnes
N/A
N/A
26/01/13
LOCATION: DERRICK
SPECIFICATION: BS 2573 MPI METHOD: N/A PARTS EXAMINED: Entire body RESULTS: No defect as at the time of inspection. Fit for use TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A
Name and address of equipment owner : Pacific Drilling
Address of premises where test / Examination was held: Pacific Bora
We hereby certify that on 27/07/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection. Fit for use Signature of Inspector: Conducting Examination Name of Inspector: OLATUNJI AKINLADE Conducting: Examination only
Revision No: 01
Doc No: JCI-C-V-01
JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: service@jcinternationalng.com Website: www.jcinternationalng.com
CERTIFICATE OF VISUAL EXAMINATION
STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998
Certificate No. 7319 Identification Number Qty
Date of Examination 27/07/2012
Examiner OLATUNJI AKINLADE TARE WT SWL
Qualifications LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Description of Equipment
Examination
FABRICATED PADEYE
LL 9-B
1
A Steel Construction Fabricated Pad Eye / Anchor Point
N/A
85 tonnes
N/A
N/A
26/01/13
LOCATION: DERRICK
SPECIFICATION: BS 2573 MPI METHOD: N/A PARTS EXAMINED: Entire body RESULTS: No defect as at the time of inspection. Fit for use TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A
Name and address of equipment owner: Pacific Drilling
Address of premises where test / Examination was held: Pacific Bora
We hereby certify that on 27/07/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection. Fit for use Signature of Inspector: Conducting Examination Name of Inspector: OLATUNJI AKINLADE Conducting: Examination only
Revision No: 01
Doc No: JCI-C-V-01
JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: service@jcinternationalng.com Website: www.jcinternationalng.com
CERTIFICATE OF VISUAL EXAMINATION
STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998
Certificate No. 7320 Identification Number Qty
Date of Examination 27/07/2012
Examiner OLATUNJI AKINLADE TARE WT SWL
Qualifications LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Description of Equipment
Examination
FABRICATED PADEYE
LL 8-A
1
A Steel Construction Fabricated Pad Eye / Anchor Point
N/A
12 tonnes
N/A
N/A
26/01/13
LOCATION: DERRICK
SPECIFICATION: BS 2573 MPI METHOD: N/A PARTS EXAMINED: Entire body RESULTS: No defect as at the time of inspection. Fit for use TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A
Name and address of equipment owner: Pacific Drilling
Address of premises where test / Examination was held: Pacific Bora
We hereby certify that on 27/07/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection. Fit for use Signature of Inspector: Conducting Examination Name of Inspector: OLATUNJI AKINLADE Conducting: Examination only
Revision No: 01
Doc No: JCI-C-V-01
JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: service@jcinternationalng.com Website: www.jcinternationalng.com
CERTIFICATE OF VISUAL EXAMINATION
STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998
Certificate No. 7321 Identification Number Qty
Date of Examination 27/07/2012
Examiner OLATUNJI AKINLADE TARE WT SWL
Qualifications LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Description of Equipment
Examination
FABRICATED PADEYE
P 021
1
A Steel Construction Fabricated Pad Eye / Anchor Point
N/A
2 tonnes
N/A
N/A
26/01/13
LOCATION: MONKEY BOARD
SPECIFICATION: BS 2573 MPI METHOD: N/A PARTS EXAMINED: Entire body RESULTS: No defect as at the time of inspection. Fit for use TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A
Name and address of equipment owner: Pacific Drilling
Address of premises where test / Examination was held: Pacific Bora
We hereby certify that on 27/07/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection. Fit for use Signature of Inspector: Conducting Examination Name of Inspector: OLATUNJI AKINLADE Conducting: Examination only
Revision No: 01
Doc No: JCI-C-V-01
JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: service@jcinternationalng.com Website: www.jcinternationalng.com
CERTIFICATE OF VISUAL EXAMINATION
STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998
Certificate No. 7322 Identification Number Qty
Date of Examination 27/07/2012
Examiner OLATUNJI AKINLADE TARE WT SWL
Qualifications LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Description of Equipment
Examination
FABRICATED PADEYE
P 022
1
A Steel Construction Fabricated Pad Eye / Anchor Point
N/A
2 tonnes
N/A
N/A
26/01/13
LOCATION: MONKEY BOARD
SPECIFICATION: BS 2573 MPI METHOD: N/A PARTS EXAMINED: Entire body RESULTS: No defect as at the time of inspection. Fit for use TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A
Name and address of equipment owner : Pacific Drilling
Address of premises where test / Examination was held: Pacific Bora
We hereby certify that on 27/07/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection. Fit for use Signature of Inspector: Conducting Examination Name of Inspector: OLATUNJI AKINLADE Conducting: Examination only
Revision No: 01
Doc No: JCI-C-V-01
JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: service@jcinternationalng.com Website: www.jcinternationalng.com
CERTIFICATE OF VISUAL EXAMINATION
STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998
Certificate No. 7323 Identification Number Qty
Date of Examination 27/07/2012
Examiner OLATUNJI AKINLADE TARE WT SWL
Qualifications LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Description of Equipment
Examination
FABRICATED PADEYE
P 020
1
A Steel Construction Fabricated Pad Eye / Anchor Point
N/A
2 tonnes
N/A
N/A
26/01/13
LOCATION: MONKEY BOARD
SPECIFICATION: BS 2573 MPI METHOD: N/A PARTS EXAMINED: Entire body RESULTS: No defect as at the time of inspection. Fit for use TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A
Name and address of equipment owner : Pacific Drilling
Address of premises where test / Examination was held: Pacific Bora
We hereby certify that on 27/07/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection. Fit for use Signature of Inspector: Conducting Examination Name of Inspector: OLATUNJI AKINLADE Conducting: Examination only
Revision No: 01
Doc No: JCI-C-V-01
JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: service@jcinternationalng.com Website: www.jcinternationalng.com
CERTIFICATE OF VISUAL EXAMINATION
STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998
Certificate No. 7325 Identification Number Qty
Date of Examination 27/07/2012
Examiner OLATUNJI AKINLADE TARE WT SWL
Qualifications LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Description of Equipment
Examination
FABRICATED PADEYE
P 019
1
A Steel Construction Fabricated Pad Eye / Anchor Point
N/A
2 tonnes
N/A
N/A
26/01/13
LOCATION: MONKEY BOARD
SPECIFICATION: BS 2573 MPI METHOD: N/A PARTS EXAMINED: Entire body RESULTS: No defect as at the time of inspection. Fit for use TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A
Name and address of equipment owner : Pacific Drilling
Address of premises where test / Examination was held: Pacific Bora
We hereby certify that on 27/07/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection. Fit for use Signature of Inspector: Conducting Examination Name of Inspector: OLATUNJI AKINLADE Conducting: Examination only
Revision No: 01
Doc No: JCI-C-V-01
JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: service@jcinternationalng.com Website: www.jcinternationalng.com
CERTIFICATE OF VISUAL EXAMINATION
STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998
Certificate No. 7326 Identification Number Qty
Date of Examination 27/07/2012
Examiner OLATUNJI AKINLADE TARE WT SWL
Qualifications LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Description of Equipment
Examination
FABRICATED PADEYE
P 023
1
A Steel Construction Fabricated Pad Eye / Anchor Point
N/A
2 tonnes
N/A
N/A
26/01/13
LOCATION: MONKEY BOARD
SPECIFICATION: BS 2573 MPI METHOD: N/A PARTS EXAMINED: Entire body RESULTS: No defect as at the time of inspection. Fit for use TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A
Name and address of equipment owner : Pacific Drilling
Address of premises where test / Examination was held: Pacific Bora
We hereby certify that on 27/07/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection. Fit for use Signature of Inspector: Conducting Examination Name of Inspector: OLATUNJI AKINLADE Conducting: Examination only
Revision No: 01
Doc No: JCI-C-V-01
JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: service@jcinternationalng.com Website: www.jcinternationalng.com
CERTIFICATE OF VISUAL EXAMINATION
STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998
Certificate No. 7327 Identification Number Qty
Date of Examination 27/07/2012
Examiner OLATUNJI AKINLADE TARE WT SWL
Qualifications LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Description of Equipment
Examination
FABRICATED PADEYE
P 015
1
A Steel Construction Fabricated Pad Eye / Anchor Point
N/A
2 tonnes
N/A
N/A
26/01/13
LOCATION: MONKEY BOARD
SPECIFICATION: BS 2573 MPI METHOD: N/A PARTS EXAMINED: Entire body RESULTS: No defect as at the time of inspection. Fit for use TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A
Name and address of equipment owner : Pacific Drilling
Address of premises where test / Examination was held: Pacific Bora
We hereby certify that on 27/07/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection. Fit for use Signature of Inspector: Conducting Examination Name of Inspector: OLATUNJI AKINLADE Conducting: Examination only
Revision No: 01
Doc No: JCI-C-V-01
JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: service@jcinternationalng.com Website: www.jcinternationalng.com
CERTIFICATE OF VISUAL EXAMINATION
STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998
Certificate No. 7328 Identification Number Qty
Date of Examination 27/07/2012
Examiner OLATUNJI AKINLADE TARE WT SWL
Qualifications LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Description of Equipment
Examination
FABRICATED PADEYE
P 016
1
A Steel Construction Fabricated Pad Eye / Anchor Point
N/A
2 tonnes
N/A
N/A
26/01/13
LOCATION: MONKEY BOARD
SPECIFICATION: BS 2573 MPI METHOD: N/A PARTS EXAMINED: Entire body RESULTS: No defect as at the time of inspection. Fit for use TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A
Name and address of equipment owner : Pacific Drilling
Address of premises where test / Examination was held: Pacific Bora
We hereby certify that on 27/07/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection. Fit for use Signature of Inspector: Conducting Examination Name of Inspector: OLATUNJI AKINLADE Conducting: Examination only
Revision No: 01
Doc No: JCI-C-V-01
JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: service@jcinternationalng.com Website: www.jcinternationalng.com
CERTIFICATE OF VISUAL EXAMINATION
STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998
Certificate No. 7329 Identification Number Qty
Date of Examination 27/07/2012
Examiner OLATUNJI AKINLADE TARE WT SWL
Qualifications LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Description of Equipment
Examination
FABRICATED PADEYE
P 017
1
A Steel Construction Fabricated Pad Eye / Anchor Point
N/A
2 tonnes
N/A
N/A
26/01/13
LOCATION: MONKEY BOARD
SPECIFICATION: BS 2573 MPI METHOD: N/A PARTS EXAMINED: Entire body RESULTS: No defect as at the time of inspection. Fit for use TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A
Name and address of equipment owner : Pacific Drilling
Address of premises where test / Examination was held: Pacific Bora
We hereby certify that on 27/07/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection. Fit for use Signature of Inspector: Conducting Examination Name of Inspector: OLATUNJI AKINLADE Conducting: Examination only
Revision No: 01
Doc No: JCI-C-V-01
JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: service@jcinternationalng.com Website: www.jcinternationalng.com
CERTIFICATE OF VISUAL EXAMINATION
STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998
Certificate No. 7330 Identification Number Qty
Date of Examination 27/07/2012
Examiner OLATUNJI AKINLADE TARE WT SWL
Qualifications LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Description of Equipment
Examination
FABRICATED PADEYE
P 024
1
A Steel Construction Fabricated Pad Eye / Anchor Point
N/A
2 tonnes
N/A
N/A
26/01/13
LOCATION: MONKEY BOARD
SPECIFICATION: BS 2573 MPI METHOD: N/A PARTS EXAMINED: Entire body RESULTS: No defect as at the time of inspection. Fit for use TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A
Name and address of equipment owner : Pacific Drilling
Address of premises where test / Examination was held: Pacific Bora
We hereby certify that on 27/07/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection. Fit for use Signature of Inspector: Conducting Examination Name of Inspector: OLATUNJI AKINLADE Conducting: Examination only
Revision No: 01
Doc No: JCI-C-V-01
JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: service@jcinternationalng.com Website: www.jcinternationalng.com
CERTIFICATE OF VISUAL EXAMINATION AND MPI
STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998
Certificate No. 7331
Date of Examination 27/07/2012
Examiner OLATUNJI AKINLADE
Qualifications LEEA, SNT LEVEL II MT, PT & UT
Identification Number
Description of Equipment
FABRICATED PADEYE
DF 022
V Door Fabricated Pad Eye
SWL: 15 tonnes
Date of Next Examination: 26-01-13
LOCATION: DRILL FLOOR
SPECIFICATION: BS 2573 MPI METHOD: Wet Visible PARTS EXAMINED: Entire body RESULTS: No defect as at the time of inspection. Fit for use TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-020 White Contrast Aid Black Magnetic Ink
Name and address of equipment owner : Pacific Drilling
Address of premises where test / Examination was held: Pacific Bora
We hereby certify that on 27/07/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection. Fit for use Signature of Inspector: Conducting Examination Name of Inspector: OLATUNJI AKINLADE Conducting: Examination only
Revision No: 01
Doc No: JCI-C-VMPI-01
JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: service@jcinternationalng.com Website: www.jcinternationalng.com
CERTIFICATE OF VISUAL EXAMINATION AND MPI
STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998
Certificate No. 7332
Date of Examination 27/07/2012
Examiner OLATUNJI AKINLADE
Qualifications LEEA, SNT LEVEL II MT, PT & UT
Identification Number
Description of Equipment
FABRICATED PADEYE
DF 07
V Door Fabricated Pad Eye
SWL: 15 tonnes
Date of Next Examination: 26-01-13
LOCATION: DRILL FLOOR
SPECIFICATION: BS 2573 MPI METHOD: Wet Visible PARTS EXAMINED: Entire body RESULTS: No defect as at the time of inspection. Fit for use TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-020 White Contrast Aid Black Magnetic Ink
Name and address of equipment owner: Pacific Drilling
Address of premises where test / Examination was held: Pacific Bora
We hereby certify that on 27/07/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection. Fit for use Signature of Inspector: Conducting Examination Name of Inspector: OLATUNJI AKINLADE Conducting: Examination only
Revision No: 01
Doc No: JCI-C-VMPI-01
JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: service@jcinternationalng.com Website: www.jcinternationalng.com
CERTIFICATE OF VISUAL EXAMINATION AND MPI
STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998
Certificate No. 7333
Date of Examination 27/07/2012
Examiner OLATUNJI AKINLADE
Qualifications LEEA, SNT LEVEL II MT, PT & UT
Identification Number
Description of Equipment
FABRICATED PADEYE
DF 06
V Door Fabricated Pad Eye
SWL: 15 tonnes
Date of Next Examination: 26-01-13
LOCATION: DRILL FLOOR
SPECIFICATION: BS 2573 MPI METHOD: Wet Visible PARTS EXAMINED: Entire body RESULTS: No defect as at the time of inspection. Fit for use TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-020 White Contrast Aid Black Magnetic Ink
Name and address of equipment owner : Pacific Drilling
Address of premises where test / Examination was held: Pacific Bora
We hereby certify that on 27/07/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection. Fit for use Signature of Inspector: Conducting Examination Name of Inspector: OLATUNJI AKINLADE Conducting: Examination only
Revision No: 01
Doc No: JCI-C-VMPI-01
JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: service@jcinternationalng.com Website: www.jcinternationalng.com
CERTIFICATE OF VISUAL EXAMINATION AND MPI
STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998
Certificate No. 7334
Date of Examination 27/07/2012
Examiner OLATUNJI AKINLADE
Qualifications LEEA, SNT LEVEL II MT, PT & UT
Identification Number
Description of Equipment
FABRICATED PADEYE
DF 021
V Door Fabricated Pad Eye
SWL: 15 tonnes
Date of Next Examination: 26-01-13
LOCATION: DRILL FLOOR
SPECIFICATION: BS 2573 MPI METHOD: Wet Visible PARTS EXAMINED: Entire body RESULTS: No defect as at the time of inspection. Fit for use TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-020 White Contrast Aid Black Magnetic Ink
Name and address of equipment owner : Pacific Drilling
Address of premises where test / Examination was held: Pacific Bora
We hereby certify that on 27/07/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection. Fit for use Signature of Inspector: Conducting Examination Name of Inspector: OLATUNJI AKINLADE Conducting: Examination only
Revision No: 01
Doc No: JCI-C-VMPI-01
JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: service@jcinternationalng.com Website: www.jcinternationalng.com
CERTIFICATE OF VISUAL EXAMINATION AND MPI
STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998
Certificate No. 7335
Date of Examination 27/07/2012
Examiner OLATUNJI AKINLADE
Qualifications LEEA, SNT LEVEL II MT, PT & UT
Identification Number
Description of Equipment
FABRICATED PADEYE
DF 09
V Door Fabricated Pad Eye
SWL: 15 tonnes
Date of Next Examination: 26-01-13
LOCATION: DRILL FLOOR
SPECIFICATION: BS 2573 MPI METHOD: Wet Visible PARTS EXAMINED: Entire body RESULTS: No defect as at the time of inspection. Fit for use TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-020 White Contrast Aid Black Magnetic Ink
Name and address of equipment owner : Pacific Drilling
Address of premises where test / Examination was held: Pacific Bora
We hereby certify that on 27/07/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection. Fit for use Signature of Inspector: Conducting Examination Name of Inspector: OLATUNJI AKINLADE Conducting: Examination only
Revision No: 01
Doc No: JCI-C-VMPI-01
JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: service@jcinternationalng.com Website: www.jcinternationalng.com
CERTIFICATE OF VISUAL EXAMINATION AND MPI
STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998
Certificate No. 7336
Date of Examination 27/07/2012
Examiner OLATUNJI AKINLADE
Qualifications LEEA, SNT LEVEL II MT, PT & UT
Identification Number
Description of Equipment
FABRICATED PADEYE
DF 08
V Door Fabricated Pad Eye
SWL: 15 tonnes
Date of Next Examination: 26-01-13
LOCATION: DRILL FLOOR
SPECIFICATION: BS 2573 MPI METHOD: Wet Visible PARTS EXAMINED: Entire body RESULTS: No defect as at the time of inspection. Fit for use TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-020 White Contrast Aid Black Magnetic Ink
Name and address of equipment owner : Pacific Drilling
Address of premises where test / Examination was held: Pacific Bora
We hereby certify that on 27/07/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection. Fit for use Signature of Inspector: Conducting Examination Name of Inspector: OLATUNJI AKINLADE Conducting: Examination only
Revision No: 01
Doc No: JCI-C-VMPI-01
JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: service@jcinternationalng.com Website: www.jcinternationalng.com
CERTIFICATE OF VISUAL EXAMINATION AND MPI
STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998
Certificate No. 7337
Date of Examination 27/07/2012
Examiner OLATUNJI AKINLADE
Qualifications LEEA, SNT LEVEL II MT, PT & UT
Identification Number
Description of Equipment
FABRICATED PADEYE
DF 023
Fabricated Pad Eye
SWL: 25 tonnes
Date of Next Examination: 26-01-13
LOCATION: DRILL FLOOR
SPECIFICATION: BS 2573 MPI METHOD: Wet Visible PARTS EXAMINED: Entire body RESULTS: No defect as at the time of inspection. Fit for use TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-020 White Contrast Aid Black Magnetic Ink
Name and address of equipment owner : Pacific Drilling
Address of premises where test / Examination was held: Pacific Bora
We hereby certify that on 27/07/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection. Fit for use Signature of Inspector: Conducting Examination Name of Inspector: OLATUNJI AKINLADE Conducting: Examination only
Revision No: 01
Doc No: JCI-C-VMPI-01
JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: service@jcinternationalng.com Website: www.jcinternationalng.com
CERTIFICATE OF VISUAL EXAMINATION AND MPI
STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998
Certificate No. 7338
Date of Examination 27/07/2012
Examiner OLATUNJI AKINLADE
Qualifications LEEA, SNT LEVEL II MT, PT & UT
Identification Number
Description of Equipment
FABRICATED PADEYE
DF 010
Snub Post Fabricated Pad Eye
SWL: 15 tonnes
Date of Next Examination: 26-01-13
LOCATION: DRILL FLOOR
SPECIFICATION: BS 2573 MPI METHOD: Wet Visible PARTS EXAMINED: Entire body RESULTS: No defect as at the time of inspection. Fit for use TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-020 White Contrast Aid Black Magnetic Ink
Name and address of equipment owner : Pacific Drilling
Address of premises where test / Examination was held: Pacific Bora
We hereby certify that on 27/07/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection. Fit for use Signature of Inspector: Conducting Examination Name of Inspector: OLATUNJI AKINLADE Conducting: Examination only
Revision No: 01
Doc No: JCI-C-VMPI-01
JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: service@jcinternationalng.com Website: www.jcinternationalng.com
CERTIFICATE OF VISUAL EXAMINATION
STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998
Certificate No. 7339 Identification Number Qty
Date of Examination 27/07/2012
Examiner OLATUNJI AKINLADE TARE WT SWL
Qualifications LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Description of Equipment
Examination
FABRICATED PADEYE
RCD-01
1
A Steel Construction Fabricated Pad Eye / Anchor Point
N/A
3 tonnes
N/A
N/A
26/01/13
LOCATION: RISER CAT WALK
SPECIFICATION: BS 2573 MPI METHOD: N/A PARTS EXAMINED: Entire body RESULTS: No defect as at the time of inspection. Fit for use TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A
Name and address of equipment owner: Pacific Drilling
Address of premises where test / Examination was held: Pacific Bora
We hereby certify that on 27/07/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection. Fit for use Signature of Inspector: Conducting Examination Name of Inspector: OLATUNJI AKINLADE Conducting: Examination only
Revision No: 01
Doc No: JCI-C-V-01
JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: service@jcinternationalng.com Website: www.jcinternationalng.com
CERTIFICATE OF VISUAL EXAMINATION
STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998
Certificate No. 7340 Identification Number Qty
Date of Examination 27/07/2012
Examiner OLATUNJI AKINLADE TARE WT SWL
Qualifications LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Description of Equipment
Examination
FABRICATED PADEYE
RCD-02
1
A Steel Construction Fabricated Pad Eye / Anchor Point
N/A
3 tonnes
N/A
N/A
26/01/13
LOCATION: RISER CAT WALK
SPECIFICATION: BS 2573 MPI METHOD: N/A PARTS EXAMINED: Entire body RESULTS: No defect as at the time of inspection. Fit for use TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A
Name and address of equipment owner: Pacific Drilling
Address of premises where test / Examination was held: Pacific Bora
We hereby certify that on 27/07/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection. Fit for use Signature of Inspector: Conducting Examination Name of Inspector: OLATUNJI AKINLADE Conducting: Examination only
Revision No: 01
Doc No: JCI-C-V-01
JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: service@jcinternationalng.com Website: www.jcinternationalng.com
CERTIFICATE OF VISUAL EXAMINATION
STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998
Certificate No. 7341 Identification Number Qty
Date of Examination 27/07/2012
Examiner OLATUNJI AKINLADE TARE WT SWL
Qualifications LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Description of Equipment
Examination
FABRICATED PADEYE
RCD-03
1
A Steel Construction Fabricated Pad Eye / Anchor Point
N/A
3 tonnes
N/A
N/A
26/01/13
LOCATION: RISER CAT WALK
SPECIFICATION: BS 2573 MPI METHOD: N/A PARTS EXAMINED: Entire body RESULTS: No defect as at the time of inspection. Fit for use TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A
Name and address of equipment owner : Pacific Drilling
Address of premises where test / Examination was held: Pacific Bora
We hereby certify that on 27/07/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection. Fit for use Signature of Inspector: Conducting Examination Name of Inspector: OLATUNJI AKINLADE Conducting: Examination only
Revision No: 01
Doc No: JCI-C-V-01
JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: service@jcinternationalng.com Website: www.jcinternationalng.com
CERTIFICATE OF VISUAL EXAMINATION
STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998
Certificate No. 7342 Identification Number Qty
Date of Examination 27/07/2012
Examiner OLATUNJI AKINLADE TARE WT SWL
Qualifications LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Description of Equipment
Examination
FABRICATED PADEYE
RCD-04
1
A Steel Construction Fabricated Pad Eye / Anchor Point
N/A
3 tonnes
N/A
N/A
26/01/13
LOCATION: RISER CAT WALK
SPECIFICATION: BS 2573 MPI METHOD: N/A PARTS EXAMINED: Entire body RESULTS: No defect as at the time of inspection. Fit for use TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A
Name and address of equipment owner : Pacific Drilling
Address of premises where test / Examination was held: Pacific Bora
We hereby certify that on 27/07/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection. Fit for use Signature of Inspector: Conducting Examination Name of Inspector: OLATUNJI AKINLADE Conducting: Examination only
Revision No: 01
Doc No: JCI-C-V-01
JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: service@jcinternationalng.com Website: www.jcinternationalng.com
CERTIFICATE OF VISUAL EXAMINATION
STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998
Certificate No. 7343 Identification Number Qty
Date of Examination 27/07/2012
Examiner OLATUNJI AKINLADE TARE WT SWL
Qualifications LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Description of Equipment
Examination
FABRICATED PADEYE
RCD-05
1
A Steel Construction Fabricated Pad Eye / Anchor Point
N/A
3 tonnes
N/A
N/A
26/01/13
LOCATION: RISER CAT WALK
SPECIFICATION: BS 2573 MPI METHOD: N/A PARTS EXAMINED: Entire body RESULTS: No defect as at the time of inspection. Fit for use TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A
Name and address of equipment owner : Pacific Drilling
Address of premises where test / Examination was held: Pacific Bora
We hereby certify that on 27/07/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection. Fit for use Signature of Inspector: Conducting Examination Name of Inspector: OLATUNJI AKINLADE Conducting: Examination only
Revision No: 01
Doc No: JCI-C-V-01
JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: service@jcinternationalng.com Website: www.jcinternationalng.com
CERTIFICATE OF VISUAL EXAMINATION
STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998
Certificate No. 7344 Identification Number Qty
Date of Examination 27/07/2012
Examiner OLATUNJI AKINLADE TARE WT SWL
Qualifications LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Description of Equipment
Examination
FABRICATED PADEYE
RCD-06
1
A Steel Construction Fabricated Pad Eye / Anchor Point
N/A
3 tonnes
N/A
N/A
26/01/13
LOCATION: RISER CAT WALK
SPECIFICATION: BS 2573 MPI METHOD: N/A PARTS EXAMINED: Entire body RESULTS: No defect as at the time of inspection. Fit for use TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A
Name and address of equipment owner : Pacific Drilling
Address of premises where test / Examination was held: Pacific Bora
We hereby certify that on 27/07/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection. Fit for use Signature of Inspector: Conducting Examination Name of Inspector: OLATUNJI AKINLADE Conducting: Examination only
Revision No: 01
Doc No: JCI-C-V-01
JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: service@jcinternationalng.com Website: www.jcinternationalng.com
CERTIFICATE OF VISUAL EXAMINATION
STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998
Certificate No. 7345 Identification Number Qty
Date of Examination 27/07/2012
Examiner OLATUNJI AKINLADE TARE WT SWL
Qualifications LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Description of Equipment
Examination
FABRICATED PADEYE
RCD-07
1
A Steel Construction Fabricated Pad Eye / Anchor Point
N/A
3 tonnes
N/A
N/A
26/01/13
LOCATION: RISER CAT WALK
SPECIFICATION: BS 2573 MPI METHOD: N/A PARTS EXAMINED: Entire body RESULTS: No defect as at the time of inspection. Fit for use TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A
Name and address of equipment owner : Pacific Drilling
Address of premises where test / Examination was held: Pacific Bora
We hereby certify that on 27/07/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection. Fit for use Signature of Inspector: Conducting Examination Name of Inspector: OLATUNJI AKINLADE Conducting: Examination only
Revision No: 01
Doc No: JCI-C-V-01
JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: service@jcinternationalng.com Website: www.jcinternationalng.com
CERTIFICATE OF VISUAL EXAMINATION
STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998
Certificate No. 7346 Identification Number Qty
Date of Examination 27/07/2012
Examiner OLATUNJI AKINLADE TARE WT SWL
Qualifications LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Description of Equipment
Examination
FABRICATED PADEYE
RCD-08
1
A Steel Construction Fabricated Pad Eye / Anchor Point
N/A
3 tonnes
N/A
N/A
26/01/13
LOCATION: RISER CAT WALK
SPECIFICATION: BS 2573 MPI METHOD: N/A PARTS EXAMINED: Entire body RESULTS: No defect as at the time of inspection. Fit for use TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A
Name and address of equipment owner : Pacific Drilling
Address of premises where test / Examination was held: Pacific Bora
We hereby certify that on 27/07/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection. Fit for use Signature of Inspector: Conducting Examination Name of Inspector: OLATUNJI AKINLADE Conducting: Examination only
Revision No: 01
Doc No: JCI-C-V-01
JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: service@jcinternationalng.com Website: www.jcinternationalng.com
CERTIFICATE OF VISUAL EXAMINATION
STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998
Certificate No. 7347 Identification Number Qty
Date of Examination 27/07/2012
Examiner OLATUNJI AKINLADE TARE WT SWL
Qualifications LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Description of Equipment
Examination
FABRICATED PADEYE
CB-01
1
A Steel Construction Fabricated Pad Eye / Anchor Point
N/A
3 tonnes
N/A
N/A
26/01/13
LOCATION: RISER CAT WALK
SPECIFICATION: BS 2573 MPI METHOD: N/A PARTS EXAMINED: Entire body RESULTS: No defect as at the time of inspection. Fit for use TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A
Name and address of equipment owner : Pacific Drilling
Address of premises where test / Examination was held: Pacific Bora
We hereby certify that on 27/07/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection. Fit for use Signature of Inspector: Conducting Examination Name of Inspector: OLATUNJI AKINLADE Conducting: Examination only
Revision No: 01
Doc No: JCI-C-V-01
JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: service@jcinternationalng.com Website: www.jcinternationalng.com
CERTIFICATE OF VISUAL EXAMINATION
STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998
Certificate No. 7348 Identification Number Qty
Date of Examination 27/07/2012
Examiner OLATUNJI AKINLADE TARE WT SWL
Qualifications LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Description of Equipment
Examination
FABRICATED PADEYE
CB-02
1
A Steel Construction Fabricated Pad Eye / Anchor Point
N/A
3 tonnes
N/A
N/A
26/01/13
LOCATION: RISER CAT WALK
SPECIFICATION: BS 2573 MPI METHOD: N/A PARTS EXAMINED: Entire body RESULTS: No defect as at the time of inspection. Fit for use TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A
Name and address of equipment owner : Pacific Drilling
Address of premises where test / Examination was held: Pacific Bora
We hereby certify that on 27/07/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection. Fit for use Signature of Inspector: Conducting Examination Name of Inspector: OLATUNJI AKINLADE Conducting: Examination only
Revision No: 01
Doc No: JCI-C-V-01
JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: service@jcinternationalng.com Website: www.jcinternationalng.com
CERTIFICATE OF VISUAL EXAMINATION
STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998
Certificate No. 7349 Identification Number Qty
Date of Examination 27/07/2012
Examiner OLATUNJI AKINLADE TARE WT SWL
Qualifications LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Description of Equipment
Examination
FABRICATED PADEYE
CB-03
1
A Steel Construction Fabricated Pad Eye / Anchor Point
N/A
3 tonnes
N/A
N/A
26/01/13
LOCATION: RISER CAT WALK
SPECIFICATION: BS 2573 MPI METHOD: N/A PARTS EXAMINED: Entire body RESULTS: No defect as at the time of inspection. Fit for use TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A
Name and address of equipment owner : Pacific Drilling
Address of premises where test / Examination was held: Pacific Bora
We hereby certify that on 27/07/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection. Fit for use Signature of Inspector: Conducting Examination Name of Inspector: OLATUNJI AKINLADE Conducting: Examination only
Revision No: 01
Doc No: JCI-C-V-01
JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: service@jcinternationalng.com Website: www.jcinternationalng.com
CERTIFICATE OF VISUAL EXAMINATION
STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998
Certificate No. 7350 Identification Number Qty
Date of Examination 27/07/2012
Examiner OLATUNJI AKINLADE TARE WT SWL
Qualifications LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Description of Equipment
Examination
FABRICATED PADEYE
CB-04
1
A Steel Construction Fabricated Pad Eye / Anchor Point
N/A
3 tonnes
N/A
N/A
26/01/13
LOCATION: RISER CAT WALK
SPECIFICATION: BS 2573 MPI METHOD: N/A PARTS EXAMINED: Entire body RESULTS: No defect as at the time of inspection. Fit for use TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A
Name and address of equipment owner : Pacific Drilling
Address of premises where test / Examination was held: Pacific Bora
We hereby certify that on 27/07/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection. Fit for use Signature of Inspector: Conducting Examination Name of Inspector: OLATUNJI AKINLADE Conducting: Examination only
Revision No: 01
Doc No: JCI-C-V-01
JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: service@jcinternationalng.com Website: www.jcinternationalng.com
CERTIFICATE OF VISUAL EXAMINATION AND MPI
STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998
Certificate No. 7351
Date of Examination 28/07/2012
Examiner OLATUNJI AKINLADE
Qualifications LEEA, SNT LEVEL II MT, PT & UT
Identification Number
Description of Equipment
FABRICATED PADEYE
DF-020
V Door Fabricated Pad Eye
SWL: 15 tonnes
Date of Next Examination: 27-01-13
LOCATION: DRILL FLOOR
SPECIFICATION: BS 2573 MPI METHOD: Wet Visible PARTS EXAMINED: Entire body RESULTS: No defect as at the time of inspection. Fit for use TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-020 White Contrast Aid Black Magnetic Ink
Name and address of equipment owner : Pacific Drilling
Address of premises where test / Examination was held: Pacific Bora
We hereby certify that on 28/07/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection. Fit for use Signature of Inspector: Conducting Examination Name of Inspector: OLATUNJI AKINLADE Conducting: Examination only
Revision No: 01
Doc No: JCI-C-VMPI-01
JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: service@jcinternationalng.com Website: www.jcinternationalng.com
CERTIFICATE OF VISUAL EXAMINATION AND MPI
STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998
Certificate No. 7352
Date of Examination 28/07/2012
Examiner OLATUNJI AKINLADE
Qualifications LEEA, SNT LEVEL II MT, PT & UT
Identification Number
Description of Equipment
FABRICATED PADEYE
DF-03
V Door Fabricated Pad Eye
SWL: 15 tonnes
Date of Next Examination: 27-01-13
LOCATION: DRILL FLOOR
SPECIFICATION: BS 2573 MPI METHOD: Wet Visible PARTS EXAMINED: Entire body RESULTS: No defect as at the time of inspection. Fit for use TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-020 White Contrast Aid Black Magnetic Ink
Name and address of equipment owner : Pacific Drilling
Address of premises where test / Examination was held: Pacific Bora
We hereby certify that on 28/07/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection. Fit for use Signature of Inspector: Conducting Examination Name of Inspector: OLATUNJI AKINLADE Conducting: Examination only
Revision No: 01
Doc No: JCI-C-VMPI-01
JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: service@jcinternationalng.com Website: www.jcinternationalng.com
CERTIFICATE OF VISUAL EXAMINATION AND MPI
STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998
Certificate No. 7353
Date of Examination 28/07/2012
Examiner OLATUNJI AKINLADE
Qualifications LEEA, SNT LEVEL II MT, PT & UT
Identification Number
Description of Equipment
FABRICATED PADEYE
DF-04
V Door Fabricated Pad Eye
SWL: 15 tonnes
Date of Next Examination: 27-01-13
LOCATION: DRILL FLOOR
SPECIFICATION: BS 2573 MPI METHOD: Wet Visible PARTS EXAMINED: Entire body RESULTS: No defect as at the time of inspection. Fit for use TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-020 White Contrast Aid Black Magnetic Ink
Name and address of equipment owner: Pacific Drilling
Address of premises where test / Examination was held: Pacific Bora
We hereby certify that on 28/07/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection. Fit for use Signature of Inspector: Conducting Examination Name of Inspector: OLATUNJI AKINLADE Conducting: Examination only
Revision No: 01
Doc No: JCI-C-VMPI-01
JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: service@jcinternationalng.com Website: www.jcinternationalng.com
CERTIFICATE OF VISUAL EXAMINATION AND MPI
STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998
Certificate No. 7354
Date of Examination 28/07/2012
Examiner OLATUNJI AKINLADE
Qualifications LEEA, SNT LEVEL II MT, PT & UT
Identification Number
Description of Equipment
FABRICATED PADEYE
DF-019
V Door Fabricated Pad Eye
SWL: 15 tonnes
Date of Next Examination: 27-01-13
LOCATION: DRILL FLOOR
SPECIFICATION: BS 2573 MPI METHOD: Wet Visible PARTS EXAMINED: Entire body RESULTS: No defect as at the time of inspection. Fit for use TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-020 White Contrast Aid Black Magnetic Ink
Name and address of equipment owner : Pacific Drilling
Address of premises where test / Examination was held: Pacific Bora
We hereby certify that on 28/07/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection. Fit for use Signature of Inspector: Conducting Examination Name of Inspector: OLATUNJI AKINLADE Conducting: Examination only
Revision No: 01
Doc No: JCI-C-VMPI-01
JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: service@jcinternationalng.com Website: www.jcinternationalng.com
CERTIFICATE OF VISUAL EXAMINATION AND MPI
STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998
Certificate No. 7355
Date of Examination 28/07/2012
Examiner OLATUNJI AKINLADE
Qualifications LEEA, SNT LEVEL II MT, PT & UT
Identification Number
Description of Equipment
FABRICATED PADEYE
DF-02
V Door Fabricated Pad Eye
SWL: 15 tonnes
Date of Next Examination: 27-01-13
LOCATION: DRILL FLOOR
SPECIFICATION: BS 2573 MPI METHOD: Wet Visible PARTS EXAMINED: Entire body RESULTS: No defect as at the time of inspection. Fit for use TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-020 White Contrast Aid Black Magnetic Ink
Name and address of equipment owner : Pacific Drilling
Address of premises where test / Examination was held: Pacific Bora
We hereby certify that on 28/07/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection. Fit for use Signature of Inspector: Conducting Examination Name of Inspector: OLATUNJI AKINLADE Conducting: Examination only
Revision No: 01
Doc No: JCI-C-VMPI-01
JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: service@jcinternationalng.com Website: www.jcinternationalng.com
CERTIFICATE OF VISUAL EXAMINATION AND MPI
STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998
Certificate No. 7356
Date of Examination 28/07/2012
Examiner OLATUNJI AKINLADE
Qualifications LEEA, SNT LEVEL II MT, PT & UT
Identification Number
Description of Equipment
FABRICATED PADEYE
DF-01
V Door Fabricated Pad Eye
SWL: 15 tonnes
Date of Next Examination: 27-01-13
LOCATION: DRILL FLOOR
SPECIFICATION: BS 2573 MPI METHOD: Wet Visible PARTS EXAMINED: Entire body RESULTS: No defect as at the time of inspection. Fit for use TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-020 White Contrast Aid Black Magnetic Ink
Name and address of equipment owner : Pacific Drilling
Address of premises where test / Examination was held: Pacific Bora
We hereby certify that on 28/07/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection. Fit for use Signature of Inspector: Conducting Examination Name of Inspector: OLATUNJI AKINLADE Conducting: Examination only
Revision No: 01
Doc No: JCI-C-VMPI-01
JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: service@jcinternationalng.com Website: www.jcinternationalng.com
CERTIFICATE OF VISUAL EXAMINATION AND MPI
STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998
Certificate No. 7357
Date of Examination 28/07/2012
Examiner OLATUNJI AKINLADE
Qualifications LEEA, SNT LEVEL II MT, PT & UT
Identification Number
Description of Equipment
FABRICATED PADEYE
SN 109
Snub Post Fabricated Pad Eye
SWL: 15 tonnes
Date of Next Examination: 27-01-13
LOCATION: DRILL FLOOR
SPECIFICATION: BS 2573 MPI METHOD: Wet Visible PARTS EXAMINED: Entire body RESULTS: No defect as at the time of inspection. Fit for use TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-020 White Contrast Aid Black Magnetic Ink
Name and address of equipment owner : Pacific Drilling
Address of premises where test / Examination was held: Pacific Bora
We hereby certify that on 28/07/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection. Fit for use Signature of Inspector: Conducting Examination Name of Inspector: OLATUNJI AKINLADE Conducting: Examination only
Revision No: 01
Doc No: JCI-C-VMPI-01
JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: service@jcinternationalng.com Website: www.jcinternationalng.com
CERTIFICATE OF VISUAL EXAMINATION AND MPI
STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998
Certificate No. 7358
Date of Examination 28/07/2012
Examiner OLATUNJI AKINLADE
Qualifications LEEA, SNT LEVEL II MT, PT & UT
Identification Number
Description of Equipment
FABRICATED PADEYE
DF 06
Snub Post Fabricated Pad Eye
SWL: 15 tonnes
Date of Next Examination: 27-01-13
LOCATION: DRILL FLOOR
SPECIFICATION: BS 2573 MPI METHOD: Wet Visible PARTS EXAMINED: Entire body RESULTS: No defect as at the time of inspection. Fit for use TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-020 White Contrast Aid Black Magnetic Ink
Name and address of equipment owner : Pacific Drilling
Address of premises where test / Examination was held: Pacific Bora
We hereby certify that on 28/07/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection. Fit for use Signature of Inspector: Conducting Examination Name of Inspector: OLATUNJI AKINLADE Conducting: Examination only
Revision No: 01
Doc No: JCI-C-VMPI-01
JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: service@jcinternationalng.com Website: www.jcinternationalng.com
CERTIFICATE OF VISUAL EXAMINATION
STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998
Certificate No. 7359 Identification Number Qty
Date of Examination 29/07/2012
Examiner OLATUNJI AKINLADE TARE WT SWL
Qualifications LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Description of Equipment
Examination
FABRICATED PADEYE
DE 001
1
A Steel Construction Fabricated Pad Eye / Anchor Point
N/A
1 tonne
N/A
N/A
28/01/13
LOCATION: TRANSFER DECK
SPECIFICATION: BS 2573 MPI METHOD: N/A PARTS EXAMINED: Entire body RESULTS: No defect as at the time of inspection. Fit for use TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A
Name and address of equipment owner : Pacific Drilling
Address of premises where test / Examination was held: Pacific Bora
We hereby certify that on 29/07/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection. Fit for use Signature of Inspector: Conducting Examination Name of Inspector: OLATUNJI AKINLADE Conducting: Examination only
Revision No: 01
Doc No: JCI-C-V-01
JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: service@jcinternationalng.com Website: www.jcinternationalng.com
CERTIFICATE OF VISUAL EXAMINATION
STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998
Certificate No. 7360 Identification Number Qty
Date of Examination 29/07/2012
Examiner OLATUNJI AKINLADE TARE WT SWL
Qualifications LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Description of Equipment
Examination
FABRICATED PADEYE
DE 002
1
A Steel Construction Fabricated Pad Eye / Anchor Point
N/A
1 tonne
N/A
N/A
28/01/13
LOCATION: TRANSFER DECK
SPECIFICATION: BS 2573 MPI METHOD: N/A PARTS EXAMINED: Entire body RESULTS: No defect as at the time of inspection. Fit for use TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A
Name and address of equipment owner : Pacific Drilling
Address of premises where test / Examination was held: Pacific Bora
We hereby certify that on 29/07/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection. Fit for use Signature of Inspector: Conducting Examination Name of Inspector: OLATUNJI AKINLADE Conducting: Examination only
Revision No: 01
Doc No: JCI-C-V-01
JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: service@jcinternationalng.com Website: www.jcinternationalng.com
CERTIFICATE OF VISUAL EXAMINATION
STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998
Certificate No. 7361 Identification Number Qty
Date of Examination 31/07/2012
Examiner OLATUNJI AKINLADE TARE WT SWL
Qualifications LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Description of Equipment
Examination
FABRICATED PADEYE
MP 012
1
A Steel Construction Fabricated Pad Eye / Anchor Point
N/A
6 tonnes
N/A
N/A
30/01/13
LOCATION: MOON POOL AREA
SPECIFICATION: BS 2573 MPI METHOD: N/A PARTS EXAMINED: Entire body RESULTS: No defect as at the time of inspection. Fit for use TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A
Name and address of equipment owner : Pacific Drilling
Address of premises where test / Examination was held: Pacific Bora
We hereby certify that on 31/07/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection. Fit for use Signature of Inspector: Conducting Examination Name of Inspector: OLATUNJI AKINLADE Conducting: Examination only
Revision No: 01
Doc No: JCI-C-V-01
JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: service@jcinternationalng.com Website: www.jcinternationalng.com
CERTIFICATE OF VISUAL EXAMINATION
STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998
Certificate No. 7362 Identification Number Qty
Date of Examination 31/07/2012
Examiner OLATUNJI AKINLADE TARE WT SWL
Qualifications LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Description of Equipment
Examination
FABRICATED PADEYE
MP 013
1
A Steel Construction Fabricated Pad Eye / Anchor Point
N/A
6 tonnes
N/A
N/A
30/01/13
LOCATION: MOON POOL AREA
SPECIFICATION: BS 2573 MPI METHOD: N/A PARTS EXAMINED: Entire body RESULTS: No defect as at the time of inspection. Fit for use TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A
Name and address of equipment owner : Pacific Drilling
Address of premises where test / Examination was held: Pacific Bora
We hereby certify that on 31/07/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection. Fit for use Signature of Inspector: Conducting Examination Name of Inspector: OLATUNJI AKINLADE Conducting: Examination only
Revision No: 01
Doc No: JCI-C-V-01
JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: service@jcinternationalng.com Website: www.jcinternationalng.com
CERTIFICATE OF VISUAL EXAMINATION
STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998
Certificate No. 7363 Identification Number Qty
Date of Examination 31/07/2012
Examiner OLATUNJI AKINLADE TARE WT SWL
Qualifications LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Description of Equipment
Examination
FABRICATED PADEYE
MP 014
1
A Steel Construction Fabricated Pad Eye / Anchor Point
N/A
6 tonnes
N/A
N/A
30/01/13
LOCATION: MOON POOL AREA
SPECIFICATION: BS 2573 MPI METHOD: N/A PARTS EXAMINED: Entire body RESULTS: No defect as at the time of inspection. Fit for use TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A
Name and address of equipment owner : Pacific Drilling
Address of premises where test / Examination was held: Pacific Bora
We hereby certify that on 31/07/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection. Fit for use Signature of Inspector: Conducting Examination Name of Inspector: OLATUNJI AKINLADE Conducting: Examination only
Revision No: 01
Doc No: JCI-C-V-01
JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: service@jcinternationalng.com Website: www.jcinternationalng.com
CERTIFICATE OF VISUAL EXAMINATION
STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998
Certificate No. 7364 Identification Number Qty
Date of Examination 31/07/2012
Examiner OLATUNJI AKINLADE TARE WT SWL
Qualifications LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Description of Equipment
Examination
FABRICATED PADEYE
MP11
1
A Steel Construction Fabricated Pad Eye / Anchor Point
N/A
12 tonnes
N/A
N/A
30/01/13
LOCATION: UNDER DRILL FLOOR
SPECIFICATION: BS 2573 MPI METHOD: N/A PARTS EXAMINED: Entire body RESULTS: No defect as at the time of inspection. Fit for use TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A
Name and address of equipment owner : Pacific Drilling
Address of premises where test / Examination was held: Pacific Bora
We hereby certify that on 31/07/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection. Fit for use Signature of Inspector: Conducting Examination Name of Inspector: OLATUNJI AKINLADE Conducting: Examination only
Revision No: 01
Doc No: JCI-C-V-01
JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: service@jcinternationalng.com Website: www.jcinternationalng.com
CERTIFICATE OF VISUAL EXAMINATION
STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998
Certificate No. 7365 Identification Number Qty
Date of Examination 31/07/2012
Examiner OLATUNJI AKINLADE TARE WT SWL
Qualifications LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Description of Equipment
Examination
FABRICATED PADEYE
XPE7
1
A Steel Construction Fabricated Pad Eye / Anchor Point
N/A
10 tonnes
N/A
N/A
30/01/13
LOCATION: UNDER DRILL FLOOR
SPECIFICATION: BS 2573 MPI METHOD: N/A PARTS EXAMINED: Entire body RESULTS: No defect as at the time of inspection. Fit for use TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A
Name and address of equipment owner : Pacific Drilling
Address of premises where test / Examination was held: Pacific Bora
We hereby certify that on 31/07/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection. Fit for use Signature of Inspector: Conducting Examination Name of Inspector: OLATUNJI AKINLADE Conducting: Examination only
Revision No: 01
Doc No: JCI-C-V-01
JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: service@jcinternationalng.com Website: www.jcinternationalng.com
CERTIFICATE OF VISUAL EXAMINATION
STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998
Certificate No. 7366 Identification Number Qty
Date of Examination 31/07/2012
Examiner OLATUNJI AKINLADE TARE WT SWL
Qualifications LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Description of Equipment
Examination
FABRICATED PADEYE
MP011
1
A Steel Construction Fabricated Pad Eye / Anchor Point
N/A
6 tonnes
N/A
N/A
30/01/13
LOCATION: MOON POOL AREA
SPECIFICATION: BS 2573 MPI METHOD: N/A PARTS EXAMINED: Entire body RESULTS: No defect as at the time of inspection. Fit for use TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A
Name and address of equipment owner : Pacific Drilling
Address of premises where test / Examination was held: Pacific Bora
We hereby certify that on 31/07/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection. Fit for use Signature of Inspector: Conducting Examination Name of Inspector: OLATUNJI AKINLADE Conducting: Examination only
Revision No: 01
Doc No: JCI-C-V-01
JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: service@jcinternationalng.com Website: www.jcinternationalng.com
CERTIFICATE OF VISUAL EXAMINATION
STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998
Certificate No. 7367 Identification Number Qty
Date of Examination 31/07/2012
Examiner OLATUNJI AKINLADE TARE WT SWL
Qualifications LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Description of Equipment
Examination
FABRICATED PADEYE
MP010
1
A Steel Construction Fabricated Pad Eye / Anchor Point
N/A
6 tonnes
N/A
N/A
30/01/13
LOCATION: MOON POOL AREA
SPECIFICATION: BS 2573 MPI METHOD: N/A PARTS EXAMINED: Entire body RESULTS: No defect as at the time of inspection. Fit for use TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A
Name and address of equipment owner : Pacific Drilling
Address of premises where test / Examination was held: Pacific Bora
We hereby certify that on 31/07/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection. Fit for use Signature of Inspector: Conducting Examination Name of Inspector: OLATUNJI AKINLADE Conducting: Examination only
Revision No: 01
Doc No: JCI-C-V-01
JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: service@jcinternationalng.com Website: www.jcinternationalng.com
CERTIFICATE OF VISUAL EXAMINATION
STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998
Certificate No. 7368 Identification Number Qty
Date of Examination 31/07/2012
Examiner OLATUNJI AKINLADE TARE WT SWL
Qualifications LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Description of Equipment
Examination
FABRICATED PADEYE
MP009
1
A Steel Construction Fabricated Pad Eye / Anchor Point
N/A
6 tonnes
N/A
N/A
30/01/13
LOCATION: MOON POOL AREA
SPECIFICATION: BS 2573 MPI METHOD: N/A PARTS EXAMINED: Entire body RESULTS: No defect as at the time of inspection. Fit for use TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A
Name and address of equipment owner : Pacific Drilling
Address of premises where test / Examination was held: Pacific Bora
We hereby certify that on 31/07/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection. Fit for use Signature of Inspector: Conducting Examination Name of Inspector: OLATUNJI AKINLADE Conducting: Examination only
Revision No: 01
Doc No: JCI-C-V-01
JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: service@jcinternationalng.com Website: www.jcinternationalng.com
CERTIFICATE OF VISUAL EXAMINATION
STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998
Certificate No. 7369 Identification Number Qty
Date of Examination 31/07/2012
Examiner OLATUNJI AKINLADE TARE WT SWL
Qualifications LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Description of Equipment
Examination
FABRICATED PADEYE
MP41
1
A Steel Construction Fabricated Pad Eye / Anchor Point
N/A
5 tonnes
N/A
N/A
30/01/13
LOCATION: UNDER DRILL FLOOR
SPECIFICATION: BS 2573 MPI METHOD: N/A PARTS EXAMINED: Entire body RESULTS: No defect as at the time of inspection. Fit for use TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A
Name and address of equipment owner : Pacific Drilling
Address of premises where test / Examination was held: Pacific Bora
We hereby certify that on 31/07/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection. Fit for use Signature of Inspector: Conducting Examination Name of Inspector: OLATUNJI AKINLADE Conducting: Examination only
Revision No: 01
Doc No: JCI-C-V-01
JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: service@jcinternationalng.com Website: www.jcinternationalng.com
CERTIFICATE OF VISUAL EXAMINATION
STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998
Certificate No. 7370 Identification Number Qty
Date of Examination 31/07/2012
Examiner OLATUNJI AKINLADE TARE WT SWL
Qualifications LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Description of Equipment
Examination
FABRICATED PADEYE
MP42
1
A Steel Construction Fabricated Pad Eye / Anchor Point
N/A
5 tonnes
N/A
N/A
30/01/13
LOCATION: UNDER DRILL FLOOR
SPECIFICATION: BS 2573 MPI METHOD: N/A PARTS EXAMINED: Entire body RESULTS: No defect as at the time of inspection. Fit for use TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A
Name and address of equipment owner : Pacific Drilling
Address of premises where test / Examination was held: Pacific Bora
We hereby certify that on 31/07/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection. Fit for use Signature of Inspector: Conducting Examination Name of Inspector: OLATUNJI AKINLADE Conducting: Examination only
Revision No: 01
Doc No: JCI-C-V-01
JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: service@jcinternationalng.com Website: www.jcinternationalng.com
CERTIFICATE OF VISUAL EXAMINATION
STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998
Certificate No. 7371 Identification Number Qty
Date of Examination 31/07/2012
Examiner OLATUNJI AKINLADE TARE WT SWL
Qualifications LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Description of Equipment
Examination
FABRICATED PADEYE
MP43
1
A Steel Construction Fabricated Pad Eye / Anchor Point
N/A
5 tonnes
N/A
N/A
30/01/13
LOCATION: UNDER DRILL FLOOR
SPECIFICATION: BS 2573 MPI METHOD: N/A PARTS EXAMINED: Entire body RESULTS: No defect as at the time of inspection. Fit for use TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A
Name and address of equipment owner : Pacific Drilling
Address of premises where test / Examination was held: Pacific Bora
We hereby certify that on 31/07/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection. Fit for use Signature of Inspector: Conducting Examination Name of Inspector: OLATUNJI AKINLADE Conducting: Examination only
Revision No: 01
Doc No: JCI-C-V-01
JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: service@jcinternationalng.com Website: www.jcinternationalng.com
CERTIFICATE OF VISUAL EXAMINATION
STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998
Certificate No. 7372 Identification Number Qty
Date of Examination 31/07/2012
Examiner OLATUNJI AKINLADE TARE WT SWL
Qualifications LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Description of Equipment
Examination
FABRICATED PADEYE
MP44
1
A Steel Construction Fabricated Pad Eye / Anchor Point
N/A
5 tonnes
N/A
N/A
30/01/13
LOCATION: UNDER DRILL FLOOR
SPECIFICATION: BS 2573 MPI METHOD: N/A PARTS EXAMINED: Entire body RESULTS: No defect as at the time of inspection. Fit for use TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A
Name and address of equipment owner: Pacific Drilling
Address of premises where test / Examination was held: Pacific Bora
We hereby certify that on 31/07/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection. Fit for use Signature of Inspector: Conducting Examination Name of Inspector: OLATUNJI AKINLADE Conducting: Examination only
Revision No: 01
Doc No: JCI-C-V-01
JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: service@jcinternationalng.com Website: www.jcinternationalng.com
CERTIFICATE OF VISUAL EXAMINATION
STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998
Certificate No. 7373 Identification Number Qty
Date of Examination 31/07/2012
Examiner OLATUNJI AKINLADE TARE WT SWL
Qualifications LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Description of Equipment
Examination
FABRICATED PADEYE
MP45
1
A Steel Construction Fabricated Pad Eye / Anchor Point
N/A
5 tonnes
N/A
N/A
30/01/13
LOCATION: UNDER DRILL FLOOR
SPECIFICATION: BS 2573 MPI METHOD: N/A PARTS EXAMINED: Entire body RESULTS: No defect as at the time of inspection. Fit for use TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A
Name and address of equipment owner: Pacific Drilling
Address of premises where test / Examination was held: Pacific Bora
We hereby certify that on 31/07/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection. Fit for use Signature of Inspector: Conducting Examination Name of Inspector: OLATUNJI AKINLADE Conducting: Examination only
Revision No: 01
Doc No: JCI-C-V-01
JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: service@jcinternationalng.com Website: www.jcinternationalng.com
CERTIFICATE OF VISUAL EXAMINATION
STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998
Certificate No. 7374 Identification Number Qty
Date of Examination 31/07/2012
Examiner OLATUNJI AKINLADE TARE WT SWL
Qualifications LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Description of Equipment
Examination
FABRICATED PADEYE
MP003
1
A Steel Construction Fabricated Pad Eye / Anchor Point
N/A
5 tonnes
N/A
N/A
30/01/13
LOCATION: UNDER DRILL FLOOR
SPECIFICATION: BS 2573 MPI METHOD: N/A PARTS EXAMINED: Entire body RESULTS: No defect as at the time of inspection. Fit for use TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A
Name and address of equipment owner : Pacific Drilling
Address of premises where test / Examination was held: Pacific Bora
We hereby certify that on 31/07/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection. Fit for use Signature of Inspector: Conducting Examination Name of Inspector: OLATUNJI AKINLADE Conducting: Examination only
Revision No: 01
Doc No: JCI-C-V-01
JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: service@jcinternationalng.com Website: www.jcinternationalng.com
CERTIFICATE OF VISUAL EXAMINATION
STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998
Certificate No. 7375 Identification Number Qty
Date of Examination 31/07/2012
Examiner OLATUNJI AKINLADE TARE WT SWL
Qualifications LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Description of Equipment
Examination
FABRICATED PADEYE
MP001
1
A Steel Construction Fabricated Pad Eye / Anchor Point
N/A
5 tonnes
N/A
N/A
30/01/13
LOCATION: UNDER DRILL FLOOR
SPECIFICATION: BS 2573 MPI METHOD: N/A PARTS EXAMINED: Entire body RESULTS: No defect as at the time of inspection. Fit for use TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A
Name and address of equipment owner : Pacific Drilling
Address of premises where test / Examination was held: Pacific Bora
We hereby certify that on 31/07/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection. Fit for use Signature of Inspector: Conducting Examination Name of Inspector: OLATUNJI AKINLADE Conducting: Examination only
Revision No: 01
Doc No: JCI-C-V-01
JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: service@jcinternationalng.com Website: www.jcinternationalng.com
CERTIFICATE OF VISUAL EXAMINATION
STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998
Certificate No. 7376 Identification Number Qty
Date of Examination 31/07/2012
Examiner OLATUNJI AKINLADE TARE WT SWL
Qualifications LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Description of Equipment
Examination
FABRICATED PADEYE
MP005
1
A Steel Construction Fabricated Pad Eye / Anchor Point
N/A
5 tonnes
N/A
N/A
30/01/13
LOCATION: UNDER DRILL FLOOR
SPECIFICATION: BS 2573 MPI METHOD: N/A PARTS EXAMINED: Entire body RESULTS: No defect as at the time of inspection. Fit for use TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A
Name and address of equipment owner : Pacific Drilling
Address of premises where test / Examination was held: Pacific Bora
We hereby certify that on 31/07/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection. Fit for use Signature of Inspector: Conducting Examination Name of Inspector: OLATUNJI AKINLADE Conducting: Examination only
Revision No: 01
Doc No: JCI-C-V-01
JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: service@jcinternationalng.com Website: www.jcinternationalng.com
CERTIFICATE OF VISUAL EXAMINATION
STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998
Certificate No. 7377 Identification Number Qty
Date of Examination 02/08/2012
Examiner OLATUNJI AKINLADE TARE WT SWL
Qualifications LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Description of Equipment
Examination
FABRICATED PADEYE
PER-007
1
A Steel Construction Fabricated Pad Eye / Anchor Point
N/A
3 tonnes
N/A
N/A
01/02/13
LOCATION: PORT SIDE ENGINE ROOM
SPECIFICATION: BS 2573 MPI METHOD: N/A PARTS EXAMINED: Entire body RESULTS: No defect as at the time of inspection. Fit for use TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A
Name and address of equipment owner : Pacific Drilling
Address of premises where test / Examination was held: Pacific Bora
We hereby certify that on 02/08/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection. Fit for use Signature of Inspector: Conducting Examination Name of Inspector: OLATUNJI AKINLADE Conducting: Examination only
Revision No: 01
Doc No: JCI-C-V-01
JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: service@jcinternationalng.com Website: www.jcinternationalng.com
CERTIFICATE OF VISUAL EXAMINATION
STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998
Certificate No. 7378 Identification Number Qty
Date of Examination 02/08/2012
Examiner OLATUNJI AKINLADE TARE WT SWL
Qualifications LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Description of Equipment
Examination
FABRICATED PADEYE
PER-008
1
A Steel Construction Fabricated Pad Eye / Anchor Point
N/A
3 tonnes
N/A
N/A
01/02/13
LOCATION: PORT SIDE ENGINE ROOM
SPECIFICATION: BS 2573 MPI METHOD: N/A PARTS EXAMINED: Entire body RESULTS: No defect as at the time of inspection. Fit for use TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A
Name and address of equipment owner : Pacific Drilling
Address of premises where test / Examination was held: Pacific Bora
We hereby certify that on 02/08/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection. Fit for use Signature of Inspector: Conducting Examination Name of Inspector: OLATUNJI AKINLADE Conducting: Examination only
Revision No: 01
Doc No: JCI-C-V-01
JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: service@jcinternationalng.com Website: www.jcinternationalng.com
CERTIFICATE OF VISUAL EXAMINATION
STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998
Certificate No. 7379 Identification Number Qty
Date of Examination 02/08/2012
Examiner OLATUNJI AKINLADE TARE WT SWL
Qualifications LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Description of Equipment
Examination
FABRICATED PADEYE
PER-009
1
A Steel Construction Fabricated Pad Eye / Anchor Point
N/A
3 tonnes
N/A
N/A
01/02/13
LOCATION: PORT SIDE ENGINE ROOM
SPECIFICATION: BS 2573 MPI METHOD: N/A PARTS EXAMINED: Entire body RESULTS: No defect as at the time of inspection. Fit for use TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A
Name and address of equipment owner : Pacific Drilling
Address of premises where test / Examination was held: Pacific Bora
We hereby certify that on 02/08/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection. Fit for use Signature of Inspector: Conducting Examination Name of Inspector: OLATUNJI AKINLADE Conducting: Examination only
Revision No: 01
Doc No: JCI-C-V-01
JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: service@jcinternationalng.com Website: www.jcinternationalng.com
CERTIFICATE OF VISUAL EXAMINATION
STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998
Certificate No. 7380 Identification Number Qty
Date of Examination 02/08/2012
Examiner OLATUNJI AKINLADE TARE WT SWL
Qualifications LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Description of Equipment
Examination
FABRICATED PADEYE
PER-010
1
A Steel Construction Fabricated Pad Eye / Anchor Point
N/A
3 tonnes
N/A
N/A
01/02/13
LOCATION: PORT SIDE ENGINE ROOM
SPECIFICATION: BS 2573 MPI METHOD: N/A PARTS EXAMINED: Entire body RESULTS: No defect as at the time of inspection. Fit for use TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A
Name and address of equipment owner : Pacific Drilling
Address of premises where test / Examination was held: Pacific Bora
We hereby certify that on 02/08/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection. Fit for use Signature of Inspector: Conducting Examination Name of Inspector: OLATUNJI AKINLADE Conducting: Examination only
Revision No: 01
Doc No: JCI-C-V-01
JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: service@jcinternationalng.com Website: www.jcinternationalng.com
CERTIFICATE OF VISUAL EXAMINATION
STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998
Certificate No. 7381 Identification Number Qty
Date of Examination 02/08/2012
Examiner OLATUNJI AKINLADE TARE WT SWL
Qualifications LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Description of Equipment
Examination
FABRICATED PADEYE
PER-018
1
A Steel Construction Fabricated Pad Eye / Anchor Point
N/A
1 tonne
N/A
N/A
01/02/13
LOCATION: PORT SIDE ENGINE ROOM
SPECIFICATION: BS 2573 MPI METHOD: N/A PARTS EXAMINED: Entire body RESULTS: No defect as at the time of inspection. Fit for use TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A
Name and address of equipment owner : Pacific Drilling
Address of premises where test / Examination was held: Pacific Bora
We hereby certify that on 02/08/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection. Fit for use Signature of Inspector: Conducting Examination Name of Inspector: OLATUNJI AKINLADE Conducting: Examination only
Revision No: 01
Doc No: JCI-C-V-01
JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: service@jcinternationalng.com Website: www.jcinternationalng.com
CERTIFICATE OF VISUAL EXAMINATION
STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998
Certificate No. 7382 Identification Number Qty
Date of Examination 02/08/2012
Examiner OLATUNJI AKINLADE TARE WT SWL
Qualifications LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Description of Equipment
Examination
FABRICATED PADEYE
PER-012
1
A Steel Construction Fabricated Pad Eye / Anchor Point
N/A
1 tonne
N/A
N/A
01/02/13
LOCATION: PORT SIDE ENGINE ROOM
SPECIFICATION: BS 2573 MPI METHOD: N/A PARTS EXAMINED: Entire body RESULTS: No defect as at the time of inspection. Fit for use TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A
Name and address of equipment owner : Pacific Drilling
Address of premises where test / Examination was held: Pacific Bora
We hereby certify that on 02/08/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection. Fit for use Signature of Inspector: Conducting Examination Name of Inspector: OLATUNJI AKINLADE Conducting: Examination only
Revision No: 01
Doc No: JCI-C-V-01
JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: service@jcinternationalng.com Website: www.jcinternationalng.com
CERTIFICATE OF VISUAL EXAMINATION
STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998
Certificate No. 7383 Identification Number Qty
Date of Examination 02/08/2012
Examiner OLATUNJI AKINLADE TARE WT SWL
Qualifications LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Description of Equipment
Examination
FABRICATED PADEYE
CER-004
1
A Steel Construction Fabricated Pad Eye / Anchor Point
N/A
3 tonnes
N/A
N/A
01/02/13
LOCATION: CENTRE ENGINE ROOM
SPECIFICATION: BS 2573 MPI METHOD: N/A PARTS EXAMINED: Entire body RESULTS: No defect as at the time of inspection. Fit for use TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A
Name and address of equipment owner : Pacific Drilling
Address of premises where test / Examination was held: Pacific Bora
We hereby certify that on 02/08/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection. Fit for use Signature of Inspector: Conducting Examination Name of Inspector: OLATUNJI AKINLADE Conducting: Examination only
Revision No: 01
Doc No: JCI-C-V-01
JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: service@jcinternationalng.com Website: www.jcinternationalng.com
CERTIFICATE OF VISUAL EXAMINATION
STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998
Certificate No. 7384 Identification Number Qty
Date of Examination 02/08/2012
Examiner OLATUNJI AKINLADE TARE WT SWL
Qualifications LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Description of Equipment
Examination
FABRICATED PADEYE
CER-005
1
A Steel Construction Fabricated Pad Eye / Anchor Point
N/A
3 tonnes
N/A
N/A
01/02/13
LOCATION: CENTRE ENGINE ROOM
SPECIFICATION: BS 2573 MPI METHOD: N/A PARTS EXAMINED: Entire body RESULTS: No defect as at the time of inspection. Fit for use TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A
Name and address of equipment owner : Pacific Drilling
Address of premises where test / Examination was held: Pacific Bora
We hereby certify that on 02/08/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection. Fit for use Signature of Inspector: Conducting Examination Name of Inspector: OLATUNJI AKINLADE Conducting: Examination only
Revision No: 01
Doc No: JCI-C-V-01
JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: service@jcinternationalng.com Website: www.jcinternationalng.com
CERTIFICATE OF VISUAL EXAMINATION
STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998
Certificate No. 7385 Identification Number Qty
Date of Examination 02/08/2012
Examiner OLATUNJI AKINLADE TARE WT SWL
Qualifications LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Description of Equipment
Examination
FABRICATED PADEYE
CER-006
1
A Steel Construction Fabricated Pad Eye / Anchor Point
N/A
3 tonnes
N/A
N/A
01/02/13
LOCATION: CENTRE ENGINE ROOM
SPECIFICATION: BS 2573 MPI METHOD: N/A PARTS EXAMINED: Entire body RESULTS: No defect as at the time of inspection. Fit for use TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A
Name and address of equipment owner: Pacific Drilling
Address of premises where test / Examination was held: Pacific Bora
We hereby certify that on 02/08/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection. Fit for use Signature of Inspector: Conducting Examination Name of Inspector: OLATUNJI AKINLADE Conducting: Examination only
Revision No: 01
Doc No: JCI-C-V-01
JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: service@jcinternationalng.com Website: www.jcinternationalng.com
CERTIFICATE OF VISUAL EXAMINATION
STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998
Certificate No. 7386 Identification Number Qty
Date of Examination 02/08/2012
Examiner OLATUNJI AKINLADE TARE WT SWL
Qualifications LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Description of Equipment
Examination
FABRICATED PADEYE
CER-007
1
A Steel Construction Fabricated Pad Eye / Anchor Point
N/A
3 tonnes
N/A
N/A
01/02/13
LOCATION: CENTRE ENGINE ROOM
SPECIFICATION: BS 2573 MPI METHOD: N/A PARTS EXAMINED: Entire body RESULTS: No defect as at the time of inspection. Fit for use TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A
Name and address of equipment owner: Pacific Drilling
Address of premises where test / Examination was held: Pacific Bora
We hereby certify that on 02/08/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection. Fit for use Signature of Inspector: Conducting Examination Name of Inspector: OLATUNJI AKINLADE Conducting: Examination only
Revision No: 01
Doc No: JCI-C-V-01
JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: service@jcinternationalng.com Website: www.jcinternationalng.com
CERTIFICATE OF VISUAL EXAMINATION
STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998
Certificate No. 7387 Identification Number Qty
Date of Examination 02/08/2012
Examiner OLATUNJI AKINLADE TARE WT SWL
Qualifications LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Description of Equipment
Examination
FABRICATED PADEYE
TR-6004
1
A Steel Construction Fabricated Pad Eye / Anchor Point
N/A
3 tonnes
N/A
N/A
01/02/13
LOCATION: CENTRE ENGINE ROOM
SPECIFICATION: BS 2573 MPI METHOD: N/A PARTS EXAMINED: Entire body RESULTS: No defect as at the time of inspection. Fit for use TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A
Name and address of equipment owner : Pacific Drilling
Address of premises where test / Examination was held: Pacific Bora
We hereby certify that on 02/08/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection. Fit for use Signature of Inspector: Conducting Examination Name of Inspector: OLATUNJI AKINLADE Conducting: Examination only
Revision No: 01
Doc No: JCI-C-V-01
JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: service@jcinternationalng.com Website: www.jcinternationalng.com
CERTIFICATE OF VISUAL EXAMINATION
STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998
Certificate No. 7388 Identification Number Qty
Date of Examination 02/08/2012
Examiner OLATUNJI AKINLADE TARE WT SWL
Qualifications LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Description of Equipment
Examination
FABRICATED PADEYE
SER-007
1
A Steel Construction Fabricated Pad Eye / Anchor Point
N/A
3 tonnes
N/A
N/A
01/02/13
LOCATION: STBD SIDE ENGINE ROOM
SPECIFICATION: BS 2573 MPI METHOD: N/A PARTS EXAMINED: Entire body RESULTS: No defect as at the time of inspection. Fit for use TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A
Name and address of equipment owner : Pacific Drilling
Address of premises where test / Examination was held: Pacific Bora
We hereby certify that on 02/08/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection. Fit for use Signature of Inspector: Conducting Examination Name of Inspector: OLATUNJI AKINLADE Conducting: Examination only
Revision No: 01
Doc No: JCI-C-V-01
JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: service@jcinternationalng.com Website: www.jcinternationalng.com
CERTIFICATE OF VISUAL EXAMINATION
STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998
Certificate No. 7389 Identification Number Qty
Date of Examination 02/08/2012
Examiner OLATUNJI AKINLADE TARE WT SWL
Qualifications LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Description of Equipment
Examination
FABRICATED PADEYE
SER-008
1
A Steel Construction Fabricated Pad Eye / Anchor Point
N/A
3 tonnes
N/A
N/A
01/02/13
LOCATION: STBD SIDE ENGINE ROOM
SPECIFICATION: BS 2573 MPI METHOD: N/A PARTS EXAMINED: Entire body RESULTS: No defect as at the time of inspection. Fit for use TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A
Name and address of equipment owner : Pacific Drilling
Address of premises where test / Examination was held: Pacific Bora
We hereby certify that on 02/08/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection. Fit for use Signature of Inspector: Conducting Examination Name of Inspector: OLATUNJI AKINLADE Conducting: Examination only
Revision No: 01
Doc No: JCI-C-V-01
JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: service@jcinternationalng.com Website: www.jcinternationalng.com
CERTIFICATE OF VISUAL EXAMINATION
STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998
Certificate No. 7390 Identification Number Qty
Date of Examination 02/08/2012
Examiner OLATUNJI AKINLADE TARE WT SWL
Qualifications LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Description of Equipment
Examination
FABRICATED PADEYE
SER-009
1
A Steel Construction Fabricated Pad Eye / Anchor Point
N/A
3 tonnes
N/A
N/A
01/02/13
LOCATION: STBD SIDE ENGINE ROOM
SPECIFICATION: BS 2573 MPI METHOD: N/A PARTS EXAMINED: Entire body RESULTS: No defect as at the time of inspection. Fit for use TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A
Name and address of equipment owner : Pacific Drilling
Address of premises where test / Examination was held: Pacific Bora
We hereby certify that on 02/08/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection. Fit for use Signature of Inspector: Conducting Examination Name of Inspector: OLATUNJI AKINLADE Conducting: Examination only
Revision No: 01
Doc No: JCI-C-V-01
JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: service@jcinternationalng.com Website: www.jcinternationalng.com
CERTIFICATE OF VISUAL EXAMINATION
STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998
Certificate No. 7391 Identification Number Qty
Date of Examination 02/08/2012
Examiner OLATUNJI AKINLADE TARE WT SWL
Qualifications LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Description of Equipment
Examination
FABRICATED PADEYE
SER-010
1
A Steel Construction Fabricated Pad Eye / Anchor Point
N/A
3 tonnes
N/A
N/A
01/02/13
LOCATION: STBD SIDE ENGINE ROOM
SPECIFICATION: BS 2573 MPI METHOD: N/A PARTS EXAMINED: Entire body RESULTS: No defect as at the time of inspection. Fit for use TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A
Name and address of equipment owner : Pacific Drilling
Address of premises where test / Examination was held: Pacific Bora
We hereby certify that on 02/08/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection. Fit for use Signature of Inspector: Conducting Examination Name of Inspector: OLATUNJI AKINLADE Conducting: Examination only
Revision No: 01
Doc No: JCI-C-V-01
JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: service@jcinternationalng.com Website: www.jcinternationalng.com
CERTIFICATE OF VISUAL EXAMINATION
STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998
Certificate No. 7392 Identification Number Qty
Date of Examination 02/08/2012
Examiner OLATUNJI AKINLADE TARE WT SWL
Qualifications LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Description of Equipment
Examination
FABRICATED PADEYE
SER-012
1
A Steel Construction Fabricated Pad Eye / Anchor Point
N/A
3 tonnes
N/A
N/A
01/02/13
LOCATION: STBD SIDE ENGINE ROOM
SPECIFICATION: BS 2573 MPI METHOD: N/A PARTS EXAMINED: Entire body RESULTS: No defect as at the time of inspection. Fit for use TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A
Name and address of equipment owner : Pacific Drilling
Address of premises where test / Examination was held: Pacific Bora
We hereby certify that on 02/08/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection. Fit for use Signature of Inspector: Conducting Examination Name of Inspector: OLATUNJI AKINLADE Conducting: Examination only
Revision No: 01
Doc No: JCI-C-V-01
JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: service@jcinternationalng.com Website: www.jcinternationalng.com
CERTIFICATE OF VISUAL EXAMINATION
STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998
Certificate No. 7393 Identification Number Qty
Date of Examination 02/08/2012
Examiner OLATUNJI AKINLADE TARE WT SWL
Qualifications LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Description of Equipment
Examination
FABRICATED PADEYE
SER-013
1
A Steel Construction Fabricated Pad Eye / Anchor Point
N/A
3 tonnes
N/A
N/A
01/02/13
LOCATION: STBD SIDE ENGINE ROOM
SPECIFICATION: BS 2573 MPI METHOD: N/A PARTS EXAMINED: Entire body RESULTS: No defect as at the time of inspection. Fit for use TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A
Name and address of equipment owner : Pacific Drilling
Address of premises where test / Examination was held: Pacific Bora
We hereby certify that on 02/08/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection. Fit for use Signature of Inspector: Conducting Examination Name of Inspector: OLATUNJI AKINLADE Conducting: Examination only
Revision No: 01
Doc No: JCI-C-V-01
JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: service@jcinternationalng.com Website: www.jcinternationalng.com
CERTIFICATE OF VISUAL EXAMINATION
STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998
Certificate No. 7394 Identification Number Qty
Date of Examination 03/08/2012
Examiner OLATUNJI AKINLADE TARE WT SWL
Qualifications LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Description of Equipment
Examination
FABRICATED PADEYE
TR2 001
1
A Steel Construction Fabricated Pad Eye / Anchor Point
N/A
1 tonne
N/A
N/A
02/02/13
LOCATION: THRUSTER NO. 2 ROOM
SPECIFICATION: BS 2573 MPI METHOD: N/A PARTS EXAMINED: Entire body RESULTS: No defect as at the time of inspection. Fit for use TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A
Name and address of equipment owner : Pacific Drilling
Address of premises where test / Examination was held: Pacific Bora
We hereby certify that on 03/08/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection. Fit for use Signature of Inspector: Conducting Examination Name of Inspector: OLATUNJI AKINLADE Conducting: Examination only
Revision No: 01
Doc No: JCI-C-V-01
JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: service@jcinternationalng.com Website: www.jcinternationalng.com
CERTIFICATE OF VISUAL EXAMINATION
STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998
Certificate No. 7395 Identification Number Qty
Date of Examination 03/08/2012
Examiner OLATUNJI AKINLADE TARE WT SWL
Qualifications LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Description of Equipment
Examination
FABRICATED PADEYE
TR2 002
1
A Steel Construction Fabricated Pad Eye / Anchor Point
N/A
1 tonne
N/A
N/A
02/02/13
LOCATION: THRUSTER NO. 2 ROOM
SPECIFICATION: BS 2573 MPI METHOD: N/A PARTS EXAMINED: Entire body RESULTS: No defect as at the time of inspection. Fit for use TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A
Name and address of equipment owner : Pacific Drilling
Address of premises where test / Examination was held: Pacific Bora
We hereby certify that on 03/08/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection. Fit for use Signature of Inspector: Conducting Examination Name of Inspector: OLATUNJI AKINLADE Conducting: Examination only
Revision No: 01
Doc No: JCI-C-V-01
JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: service@jcinternationalng.com Website: www.jcinternationalng.com
CERTIFICATE OF VISUAL EXAMINATION
STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998
Certificate No. 7396 Identification Number Qty
Date of Examination 03/08/2012
Examiner OLATUNJI AKINLADE TARE WT SWL
Qualifications LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Description of Equipment
Examination
FABRICATED PADEYE
TR2 003
1
A Steel Construction Fabricated Pad Eye / Anchor Point
N/A
1 tonne
N/A
N/A
02/02/13
LOCATION: THRUSTER NO. 2 ROOM
SPECIFICATION: BS 2573 MPI METHOD: N/A PARTS EXAMINED: Entire body RESULTS: No defect as at the time of inspection. Fit for use TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A
Name and address of equipment owner : Pacific Drilling
Address of premises where test / Examination was held: Pacific Bora
We hereby certify that on 03/08/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection. Fit for use Signature of Inspector: Conducting Examination Name of Inspector: OLATUNJI AKINLADE Conducting: Examination only
Revision No: 01
Doc No: JCI-C-V-01
JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: service@jcinternationalng.com Website: www.jcinternationalng.com
CERTIFICATE OF VISUAL EXAMINATION
STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998
Certificate No. 7397 Identification Number Qty
Date of Examination 03/08/2012
Examiner OLATUNJI AKINLADE TARE WT SWL
Qualifications LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Description of Equipment
Examination
FABRICATED PADEYE
TR2 004
1
A Steel Construction Fabricated Pad Eye / Anchor Point
N/A
1 tonne
N/A
N/A
02/02/13
LOCATION: THRUSTER NO. 2 ROOM
SPECIFICATION: BS 2573 MPI METHOD: N/A PARTS EXAMINED: Entire body RESULTS: No defect as at the time of inspection. Fit for use TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A
Name and address of equipment owner: Pacific Drilling
Address of premises where test / Examination was held: Pacific Bora
We hereby certify that on 03/08/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection. Fit for use Signature of Inspector: Conducting Examination Name of Inspector: OLATUNJI AKINLADE Conducting: Examination only
Revision No: 01
Doc No: JCI-C-V-01
JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: service@jcinternationalng.com Website: www.jcinternationalng.com
CERTIFICATE OF VISUAL EXAMINATION
STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998
Certificate No. 7398 Identification Number Qty
Date of Examination 03/08/2012
Examiner OLATUNJI AKINLADE TARE WT SWL
Qualifications LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Description of Equipment
Examination
FABRICATED PADEYE
TR2 005
1
A Steel Construction Fabricated Pad Eye / Anchor Point
N/A
3 tonnes
N/A
N/A
02/02/13
LOCATION: THRUSTER NO. 2 ROOM
SPECIFICATION: BS 2573 MPI METHOD: N/A PARTS EXAMINED: Entire body RESULTS: No defect as at the time of inspection. Fit for use TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A
Name and address of equipment owner : Pacific Drilling
Address of premises where test / Examination was held: Pacific Bora
We hereby certify that on 03/08/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection. Fit for use Signature of Inspector: Conducting Examination Name of Inspector: OLATUNJI AKINLADE Conducting: Examination only
Revision No: 01
Doc No: JCI-C-V-01
JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: service@jcinternationalng.com Website: www.jcinternationalng.com
CERTIFICATE OF VISUAL EXAMINATION
STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998
Certificate No. 7399 Identification Number Qty
Date of Examination 03/08/2012
Examiner OLATUNJI AKINLADE TARE WT SWL
Qualifications LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Description of Equipment
Examination
FABRICATED PADEYE
TR3 001
1
A Steel Construction Fabricated Pad Eye / Anchor Point
N/A
1 tonne
N/A
N/A
02/02/13
LOCATION: THRUSTER NO. 3 ROOM
SPECIFICATION: BS 2573 MPI METHOD: N/A PARTS EXAMINED: Entire body RESULTS: No defect as at the time of inspection. Fit for use TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A
Name and address of equipment owner : Pacific Drilling
Address of premises where test / Examination was held: Pacific Bora
We hereby certify that on 03/08/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection. Fit for use Signature of Inspector: Conducting Examination Name of Inspector: OLATUNJI AKINLADE Conducting: Examination only
Revision No: 01
Doc No: JCI-C-V-01
JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: service@jcinternationalng.com Website: www.jcinternationalng.com
CERTIFICATE OF VISUAL EXAMINATION
STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998
Certificate No. 7400 Identification Number Qty
Date of Examination 03/08/2012
Examiner OLATUNJI AKINLADE TARE WT SWL
Qualifications LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Description of Equipment
Examination
FABRICATED PADEYE
TR3 002
1
A Steel Construction Fabricated Pad Eye / Anchor Point
N/A
1 tonne
N/A
N/A
02/02/13
LOCATION: THRUSTER NO. 3 ROOM
SPECIFICATION: BS 2573 MPI METHOD: N/A PARTS EXAMINED: Entire body RESULTS: No defect as at the time of inspection. Fit for use TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A
Name and address of equipment owner : Pacific Drilling
Address of premises where test / Examination was held: Pacific Bora
We hereby certify that on 03/08/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection. Fit for use Signature of Inspector: Conducting Examination Name of Inspector: OLATUNJI AKINLADE Conducting: Examination only
Revision No: 01
Doc No: JCI-C-V-01
JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: service@jcinternationalng.com Website: www.jcinternationalng.com
CERTIFICATE OF VISUAL EXAMINATION
STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998
Certificate No. 7401 Identification Number Qty
Date of Examination 03/08/2012
Examiner OLATUNJI AKINLADE TARE WT SWL
Qualifications LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Description of Equipment
Examination
FABRICATED PADEYE
TR3 003
1
A Steel Construction Fabricated Pad Eye / Anchor Point
N/A
1 tonne
N/A
N/A
02/02/13
LOCATION: THRUSTER NO. 3 ROOM
SPECIFICATION: BS 2573 MPI METHOD: N/A PARTS EXAMINED: Entire body RESULTS: No defect as at the time of inspection. Fit for use TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A
Name and address of equipment owner : Pacific Drilling
Address of premises where test / Examination was held: Pacific Bora
We hereby certify that on 03/08/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection. Fit for use Signature of Inspector: Conducting Examination Name of Inspector: OLATUNJI AKINLADE Conducting: Examination only
Revision No: 01
Doc No: JCI-C-V-01
JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: service@jcinternationalng.com Website: www.jcinternationalng.com
CERTIFICATE OF VISUAL EXAMINATION
STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998
Certificate No. 7402 Identification Number Qty
Date of Examination 03/08/2012
Examiner OLATUNJI AKINLADE TARE WT SWL
Qualifications LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Description of Equipment
Examination
FABRICATED PADEYE
TR3 004
1
A Steel Construction Fabricated Pad Eye / Anchor Point
N/A
1 tonne
N/A
N/A
02/02/13
LOCATION: THRUSTER NO. 3 ROOM
SPECIFICATION: BS 2573 MPI METHOD: N/A PARTS EXAMINED: Entire body RESULTS: No defect as at the time of inspection. Fit for use TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A
Name and address of equipment owner : Pacific Drilling
Address of premises where test / Examination was held: Pacific Bora
We hereby certify that on 03/08/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection. Fit for use Signature of Inspector: Conducting Examination Name of Inspector: OLATUNJI AKINLADE Conducting: Examination only
Revision No: 01
Doc No: JCI-C-V-01
JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: service@jcinternationalng.com Website: www.jcinternationalng.com
CERTIFICATE OF VISUAL EXAMINATION
STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998
Certificate No. 7403 Identification Number Qty
Date of Examination 03/08/2012
Examiner OLATUNJI AKINLADE TARE WT SWL
Qualifications LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Description of Equipment
Examination
FABRICATED PADEYE
TR3 005
1
A Steel Construction Fabricated Pad Eye / Anchor Point
N/A
3 tonnes
N/A
N/A
02/02/13
LOCATION: THRUSTER NO. 3 ROOM
SPECIFICATION: BS 2573 MPI METHOD: N/A PARTS EXAMINED: Entire body RESULTS: No defect as at the time of inspection. Fit for use TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A
Name and address of equipment owner : Pacific Drilling
Address of premises where test / Examination was held: Pacific Bora
We hereby certify that on 03/08/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection. Fit for use Signature of Inspector: Conducting Examination Name of Inspector: OLATUNJI AKINLADE Conducting: Examination only
Revision No: 01
Doc No: JCI-C-V-01
JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: service@jcinternationalng.com Website: www.jcinternationalng.com
CERTIFICATE OF VISUAL EXAMINATION
STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998
Certificate No. 7404 Identification Number Qty
Date of Examination 03/08/2012
Examiner OLATUNJI AKINLADE TARE WT SWL
Qualifications LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Description of Equipment
Examination
FABRICATED PADEYE
FAR 001
1
A Steel Construction Fabricated Pad Eye / Anchor Point
N/A
3 tonnes
N/A
N/A
02/02/13
LOCATION: FWD AUX. MACH ROOM
SPECIFICATION: BS 2573 MPI METHOD: N/A PARTS EXAMINED: Entire body RESULTS: No defect as at the time of inspection. Fit for use TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A
Name and address of equipment owner : Pacific Drilling
Address of premises where test / Examination was held: Pacific Bora
We hereby certify that on 03/08/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection. Fit for use Signature of Inspector: Conducting Examination Name of Inspector: OLATUNJI AKINLADE Conducting: Examination only
Revision No: 01
Doc No: JCI-C-V-01
JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: service@jcinternationalng.com Website: www.jcinternationalng.com
CERTIFICATE OF VISUAL EXAMINATION
STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998
Certificate No. 7405 Identification Number Qty
Date of Examination 03/08/2012
Examiner OLATUNJI AKINLADE TARE WT SWL
Qualifications LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Description of Equipment
Examination
FABRICATED PADEYE
TR1 001
1
A Steel Construction Fabricated Pad Eye / Anchor Point
N/A
3 tonnes
N/A
N/A
02/02/13
LOCATION: THRUSTER NO. 1 ROOM
SPECIFICATION: BS 2573 MPI METHOD: N/A PARTS EXAMINED: Entire body RESULTS: No defect as at the time of inspection. Fit for use TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A
Name and address of equipment owner : Pacific Drilling
Address of premises where test / Examination was held: Pacific Bora
We hereby certify that on 03/08/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection. Fit for use Signature of Inspector: Conducting Examination Name of Inspector: OLATUNJI AKINLADE Conducting: Examination only
Revision No: 01
Doc No: JCI-C-V-01
JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: service@jcinternationalng.com Website: www.jcinternationalng.com
CERTIFICATE OF VISUAL EXAMINATION
STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998
Certificate No. 7406 Identification Number Qty
Date of Examination 03/08/2012
Examiner OLATUNJI AKINLADE TARE WT SWL
Qualifications LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Description of Equipment
Examination
FABRICATED PADEYE
TR4 001
1
A Steel Construction Fabricated Pad Eye / Anchor Point
N/A
1 tonne
N/A
N/A
02/02/13
LOCATION: THRUSTER NO. 4 ROOM
SPECIFICATION: BS 2573 MPI METHOD: N/A PARTS EXAMINED: Entire body RESULTS: No defect as at the time of inspection. Fit for use TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A
Name and address of equipment owner : Pacific Drilling
Address of premises where test / Examination was held: Pacific Bora
We hereby certify that on 03/08/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection. Fit for use Signature of Inspector: Conducting Examination Name of Inspector: OLATUNJI AKINLADE Conducting: Examination only
Revision No: 01
Doc No: JCI-C-V-01
JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: service@jcinternationalng.com Website: www.jcinternationalng.com
CERTIFICATE OF VISUAL EXAMINATION
STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998
Certificate No. 7407 Identification Number Qty
Date of Examination 03/08/2012
Examiner OLATUNJI AKINLADE TARE WT SWL
Qualifications LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Description of Equipment
Examination
FABRICATED PADEYE
TR4002
1
A Steel Construction Fabricated Pad Eye / Anchor Point
N/A
3 tonnes
N/A
N/A
02/02/13
LOCATION: THRUSTER NO. 4 ROOM
SPECIFICATION: BS 2573 MPI METHOD: N/A PARTS EXAMINED: Entire body RESULTS: No defect as at the time of inspection. Fit for use TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A
Name and address of equipment owner : Pacific Drilling
Address of premises where test / Examination was held: Pacific Bora
We hereby certify that on 03/08/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection. Fit for use Signature of Inspector: Conducting Examination Name of Inspector: OLATUNJI AKINLADE Conducting: Examination only
Revision No: 01
Doc No: JCI-C-V-01
JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: service@jcinternationalng.com Website: www.jcinternationalng.com
CERTIFICATE OF VISUAL EXAMINATION
STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998
Certificate No. 7408 Identification Number Qty
Date of Examination 03/08/2012
Examiner OLATUNJI AKINLADE TARE WT SWL
Qualifications LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Description of Equipment
Examination
FABRICATED PADEYE
TR6 002
1
A Steel Construction Fabricated Pad Eye / Anchor Point
N/A
1 tonne
N/A
N/A
02/02/13
LOCATION: THRUSTER NO. 6 ROOM
SPECIFICATION: BS 2573 MPI METHOD: N/A PARTS EXAMINED: Entire body RESULTS: No defect as at the time of inspection. Fit for use TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A
Name and address of equipment owner : Pacific Drilling
Address of premises where test / Examination was held: Pacific Bora
We hereby certify that on 03/08/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection. Fit for use Signature of Inspector: Conducting Examination Name of Inspector: OLATUNJI AKINLADE Conducting: Examination only
Revision No: 01
Doc No: JCI-C-V-01
JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: service@jcinternationalng.com Website: www.jcinternationalng.com
CERTIFICATE OF VISUAL EXAMINATION
STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998
Certificate No. 7409 Identification Number Qty
Date of Examination 03/08/2012
Examiner OLATUNJI AKINLADE TARE WT SWL
Qualifications LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Description of Equipment
Examination
FABRICATED PADEYE
TR6 001
1
A Steel Construction Fabricated Pad Eye / Anchor Point
N/A
1 tonne
N/A
N/A
02/02/13
LOCATION: THRUSTER NO. 6 ROOM
SPECIFICATION: BS 2573 MPI METHOD: N/A PARTS EXAMINED: Entire body RESULTS: No defect as at the time of inspection. Fit for use TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A
Name and address of equipment owner: Pacific Drilling
Address of premises where test / Examination was held: Pacific Bora
We hereby certify that on 03/08/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection. Fit for use Signature of Inspector: Conducting Examination Name of Inspector: OLATUNJI AKINLADE Conducting: Examination only
Revision No: 01
Doc No: JCI-C-V-01
JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: service@jcinternationalng.com Website: www.jcinternationalng.com
CERTIFICATE OF VISUAL EXAMINATION
STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998
Certificate No. 7410 Identification Number Qty
Date of Examination 03/08/2012
Examiner OLATUNJI AKINLADE TARE WT SWL
Qualifications LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Description of Equipment
Examination
FABRICATED PADEYE
TR5 001
1
A Steel Construction Fabricated Pad Eye / Anchor Point
N/A
1 tonne
N/A
N/A
02/02/13
LOCATION: THRUSTER NO. 5 ROOM
SPECIFICATION: BS 2573 MPI METHOD: N/A PARTS EXAMINED: Entire body RESULTS: No defect as at the time of inspection. Fit for use TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A
Name and address of equipment owner : Pacific Drilling
Address of premises where test / Examination was held: Pacific Bora
We hereby certify that on 03/08/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection. Fit for use Signature of Inspector: Conducting Examination Name of Inspector: OLATUNJI AKINLADE Conducting: Examination only
Revision No: 01
Doc No: JCI-C-V-01
JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: service@jcinternationalng.com Website: www.jcinternationalng.com
CERTIFICATE OF VISUAL EXAMINATION
STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998
Certificate No. 7412 Identification Number Qty
Date of Examination 03/08/2012
Examiner OLATUNJI AKINLADE TARE WT SWL
Qualifications LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Description of Equipment
Examination
FABRICATED PADEYE
TR5 002
1
A Steel Construction Fabricated Pad Eye / Anchor Point
N/A
1 tonne
N/A
N/A
02/02/13
LOCATION: THRUSTER NO. 5 ROOM
SPECIFICATION: BS 2573 MPI METHOD: N/A PARTS EXAMINED: Entire body RESULTS: No defect as at the time of inspection. Fit for use TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A
Name and address of equipment owner : Pacific Drilling
Address of premises where test / Examination was held: Pacific Bora
We hereby certify that on 03/08/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection. Fit for use Signature of Inspector: Conducting Examination Name of Inspector: OLATUNJI AKINLADE Conducting: Examination only
Revision No: 01
Doc No: JCI-C-V-01
JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: service@jcinternationalng.com Website: www.jcinternationalng.com
CERTIFICATE OF VISUAL EXAMINATION
STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998
Certificate No. 7413 Identification Number Qty
Date of Examination 03/08/2012
Examiner OLATUNJI AKINLADE TARE WT SWL
Qualifications LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Description of Equipment
Examination
FABRICATED PADEYE
CER- 001
1
A Steel Construction Fabricated Pad Eye / Anchor Point
N/A
3 tonnes
N/A
N/A
02/02/13
LOCATION: CENTRE ENGINE ROOM
SPECIFICATION: BS 2573 MPI METHOD: N/A PARTS EXAMINED: Entire body RESULTS: No defect as at the time of inspection. Fit for use TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A
Name and address of equipment owner : Pacific Drilling
Address of premises where test / Examination was held: Pacific Bora
We hereby certify that on 03/08/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection. Fit for use Signature of Inspector: Conducting Examination Name of Inspector: OLATUNJI AKINLADE Conducting: Examination only
Revision No: 01
Doc No: JCI-C-V-01
JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: service@jcinternationalng.com Website: www.jcinternationalng.com
CERTIFICATE OF VISUAL EXAMINATION
STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998
Certificate No. 7414 Identification Number Qty
Date of Examination 03/08/2012
Examiner OLATUNJI AKINLADE TARE WT SWL
Qualifications LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Description of Equipment
Examination
FABRICATED PADEYE
CER- 002
1
A Steel Construction Fabricated Pad Eye / Anchor Point
N/A
3 tonnes
N/A
N/A
02/02/13
LOCATION: CENTRE ENGINE ROOM
SPECIFICATION: BS 2573 MPI METHOD: N/A PARTS EXAMINED: Entire body RESULTS: No defect as at the time of inspection. Fit for use TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A
Name and address of equipment owner : Pacific Drilling
Address of premises where test / Examination was held: Pacific Bora
We hereby certify that on 03/08/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection. Fit for use Signature of Inspector: Conducting Examination Name of Inspector: OLATUNJI AKINLADE Conducting: Examination only
Revision No: 01
Doc No: JCI-C-V-01
JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: service@jcinternationalng.com Website: www.jcinternationalng.com
CERTIFICATE OF VISUAL EXAMINATION
STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998
Certificate No. 7415 Identification Number Qty
Date of Examination 03/08/2012
Examiner OLATUNJI AKINLADE TARE WT SWL
Qualifications LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Description of Equipment
Examination
FABRICATED PADEYE
CER- 003
1
A Steel Construction Fabricated Pad Eye / Anchor Point
N/A
1 tonne
N/A
N/A
02/02/13
LOCATION: CENTRE ENGINE ROOM
SPECIFICATION: BS 2573 MPI METHOD: N/A PARTS EXAMINED: Entire body RESULTS: No defect as at the time of inspection. Fit for use TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A
Name and address of equipment owner : Pacific Drilling
Address of premises where test / Examination was held: Pacific Bora
We hereby certify that on 03/08/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection. Fit for use Signature of Inspector: Conducting Examination Name of Inspector: OLATUNJI AKINLADE Conducting: Examination only
Revision No: 01
Doc No: JCI-C-V-01
JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: service@jcinternationalng.com Website: www.jcinternationalng.com
CERTIFICATE OF VISUAL EXAMINATION
STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998
Certificate No. 7416 Identification Number Qty
Date of Examination 03/08/2012
Examiner OLATUNJI AKINLADE TARE WT SWL
Qualifications LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Description of Equipment
Examination
FABRICATED PADEYE
SER- 011
1
A Steel Construction Fabricated Pad Eye / Anchor Point
N/A
1 tonne
N/A
N/A
02/02/13
LOCATION: STBD SIDE ENGINE ROOM
SPECIFICATION: BS 2573 MPI METHOD: N/A PARTS EXAMINED: Entire body RESULTS: No defect as at the time of inspection. Fit for use TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A
Name and address of equipment owner : Pacific Drilling
Address of premises where test / Examination was held: Pacific Bora
We hereby certify that on 03/08/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection. Fit for use Signature of Inspector: Conducting Examination Name of Inspector: OLATUNJI AKINLADE Conducting: Examination only
Revision No: 01
Doc No: JCI-C-V-01
JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: service@jcinternationalng.com Website: www.jcinternationalng.com
CERTIFICATE OF VISUAL EXAMINATION
STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998
Certificate No. 7417 Identification Number Qty
Date of Examination 03/08/2012
Examiner OLATUNJI AKINLADE TARE WT SWL
Qualifications LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Description of Equipment
Examination
FABRICATED PADEYE
SER- 1
1
A Steel Construction Fabricated Pad Eye / Anchor Point
N/A
2 tonnes
N/A
N/A
02/02/13
LOCATION: STBD SIDE ENGINE ROOM
SPECIFICATION: BS 2573 MPI METHOD: N/A PARTS EXAMINED: Entire body RESULTS: No defect as at the time of inspection. Fit for use TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A
Name and address of equipment owner : Pacific Drilling
Address of premises where test / Examination was held: Pacific Bora
We hereby certify that on 03/08/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection. Fit for use Signature of Inspector: Conducting Examination Name of Inspector: OLATUNJI AKINLADE Conducting: Examination only
Revision No: 01
Doc No: JCI-C-V-01
JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: service@jcinternationalng.com Website: www.jcinternationalng.com
CERTIFICATE OF VISUAL EXAMINATION
STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998
Certificate No. 7418 Identification Number Qty
Date of Examination 03/08/2012
Examiner OLATUNJI AKINLADE TARE WT SWL
Qualifications LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Description of Equipment
Examination
FABRICATED PADEYE
SER- 2
1
A Steel Construction Fabricated Pad Eye / Anchor Point
N/A
2 tonnes
N/A
N/A
02/02/13
LOCATION: STBD SIDE ENGINE ROOM
SPECIFICATION: BS 2573 MPI METHOD: N/A PARTS EXAMINED: Entire body RESULTS: No defect as at the time of inspection. Fit for use TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A
Name and address of equipment owner : Pacific Drilling
Address of premises where test / Examination was held: Pacific Bora
We hereby certify that on 03/08/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection. Fit for use Signature of Inspector: Conducting Examination Name of Inspector: OLATUNJI AKINLADE Conducting: Examination only
Revision No: 01
Doc No: JCI-C-V-01
JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: service@jcinternationalng.com Website: www.jcinternationalng.com
CERTIFICATE OF VISUAL EXAMINATION
STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998
Certificate No. 7419 Identification Number Qty
Date of Examination 03/08/2012
Examiner OLATUNJI AKINLADE TARE WT SWL
Qualifications LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Description of Equipment
Examination
FABRICATED PADEYE
SER-3
1
A Steel Construction Fabricated Pad Eye / Anchor Point
N/A
2 tonnes
N/A
N/A
02/02/13
LOCATION: STBD SIDE ENGINE ROOM
SPECIFICATION: BS 2573 MPI METHOD: N/A PARTS EXAMINED: Entire body RESULTS: No defect as at the time of inspection. Fit for use TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A
Name and address of equipment owner : Pacific Drilling
Address of premises where test / Examination was held: Pacific Bora
We hereby certify that on 03/08/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection. Fit for use Signature of Inspector: Conducting Examination Name of Inspector: OLATUNJI AKINLADE Conducting: Examination only
Revision No: 01
Doc No: JCI-C-V-01
JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: service@jcinternationalng.com Website: www.jcinternationalng.com
CERTIFICATE OF VISUAL EXAMINATION
STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998
Certificate No. 7420 Identification Number Qty
Date of Examination 03/08/2012
Examiner OLATUNJI AKINLADE TARE WT SWL
Qualifications LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Description of Equipment
Examination
FABRICATED PADEYE
SER-4
1
A Steel Construction Fabricated Pad Eye / Anchor Point
N/A
2 tonnes
N/A
N/A
02/02/13
LOCATION: STBD SIDE ENGINE ROOM
SPECIFICATION: BS 2573 MPI METHOD: N/A PARTS EXAMINED: Entire body RESULTS: No defect as at the time of inspection. Fit for use TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A
Name and address of equipment owner : Pacific Drilling
Address of premises where test / Examination was held: Pacific Bora
We hereby certify that on 03/08/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection. Fit for use Signature of Inspector: Conducting Examination Name of Inspector: OLATUNJI AKINLADE Conducting: Examination only
Revision No: 01
Doc No: JCI-C-V-01
JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: service@jcinternationalng.com Website: www.jcinternationalng.com
CERTIFICATE OF VISUAL EXAMINATION
STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998
Certificate No. 7421 Identification Number Qty
Date of Examination 03/08/2012
Examiner OLATUNJI AKINLADE TARE WT SWL
Qualifications LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Description of Equipment
Examination
FABRICATED PADEYE
SER- 5
1
A Steel Construction Fabricated Pad Eye / Anchor Point
N/A
2 tonnes
N/A
N/A
02/02/13
LOCATION: STBD SIDE ENGINE ROOM
SPECIFICATION: BS 2573 MPI METHOD: N/A PARTS EXAMINED: Entire body RESULTS: No defect as at the time of inspection. Fit for use TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A
Name and address of equipment owner : Pacific Drilling
Address of premises where test / Examination was held: Pacific Bora
We hereby certify that on 03/08/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection. Fit for use Signature of Inspector: Conducting Examination Name of Inspector: OLATUNJI AKINLADE Conducting: Examination only
Revision No: 01
Doc No: JCI-C-V-01
JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: service@jcinternationalng.com Website: www.jcinternationalng.com
CERTIFICATE OF VISUAL EXAMINATION
STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998
Certificate No. 7422 Identification Number Qty
Date of Examination 03/08/2012
Examiner OLATUNJI AKINLADE TARE WT SWL
Qualifications LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Description of Equipment
Examination
FABRICATED PADEYE
SER- 6
1
A Steel Construction Fabricated Pad Eye / Anchor Point
N/A
2 tonnes
N/A
N/A
02/02/13
LOCATION: STBD SIDE ENGINE ROOM
SPECIFICATION: BS 2573 MPI METHOD: N/A PARTS EXAMINED: Entire body RESULTS: No defect as at the time of inspection. Fit for use TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A
Name and address of equipment owner: Pacific Drilling
Address of premises where test / Examination was held: Pacific Bora
We hereby certify that on 03/08/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection. Fit for use Signature of Inspector: Conducting Examination Name of Inspector: OLATUNJI AKINLADE Conducting: Examination only
Revision No: 01
Doc No: JCI-C-V-01
JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: service@jcinternationalng.com Website: www.jcinternationalng.com
CERTIFICATE OF VISUAL EXAMINATION
STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998
Certificate No. 7423 Identification Number Qty
Date of Examination 03/08/2012
Examiner OLATUNJI AKINLADE TARE WT SWL
Qualifications LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Description of Equipment
Examination
FABRICATED PADEYE
SER- 7
1
A Steel Construction Fabricated Pad Eye / Anchor Point
N/A
2 tonnes
N/A
N/A
02/02/13
LOCATION: STBD SIDE ENGINE ROOM
SPECIFICATION: BS 2573 MPI METHOD: N/A PARTS EXAMINED: Entire body RESULTS: No defect as at the time of inspection. Fit for use TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A
Name and address of equipment owner : Pacific Drilling
Address of premises where test / Examination was held: Pacific Bora
We hereby certify that on 03/08/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection. Fit for use Signature of Inspector: Conducting Examination Name of Inspector: OLATUNJI AKINLADE Conducting: Examination only
Revision No: 01
Doc No: JCI-C-V-01
JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: service@jcinternationalng.com Website: www.jcinternationalng.com
CERTIFICATE OF VISUAL EXAMINATION
STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998
Certificate No. 7424 Identification Number Qty
Date of Examination 03/08/2012
Examiner OLATUNJI AKINLADE TARE WT SWL
Qualifications LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Description of Equipment
Examination
FABRICATED PADEYE
SER- 8
1
A Steel Construction Fabricated Pad Eye / Anchor Point
N/A
2 tonnes
N/A
N/A
02/02/13
LOCATION: STBD SIDE ENGINE ROOM
SPECIFICATION: BS 2573 MPI METHOD: N/A PARTS EXAMINED: Entire body RESULTS: No defect as at the time of inspection. Fit for use TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A
Name and address of equipment owner : Pacific Drilling
Address of premises where test / Examination was held: Pacific Bora
We hereby certify that on 03/08/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection. Fit for use Signature of Inspector: Conducting Examination Name of Inspector: OLATUNJI AKINLADE Conducting: Examination only
Revision No: 01
Doc No: JCI-C-V-01
JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: service@jcinternationalng.com Website: www.jcinternationalng.com
CERTIFICATE OF VISUAL EXAMINATION
STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998
Certificate No. 7425 Identification Number Qty
Date of Examination 03/08/2012
Examiner OLATUNJI AKINLADE TARE WT SWL
Qualifications LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Description of Equipment
Examination
FABRICATED PADEYE
SER- 9
1
A Steel Construction Fabricated Pad Eye / Anchor Point
N/A
2 tonnes
N/A
N/A
02/02/13
LOCATION: STBD SIDE ENGINE ROOM
SPECIFICATION: BS 2573 MPI METHOD: N/A PARTS EXAMINED: Entire body RESULTS: No defect as at the time of inspection. Fit for use TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A
Name and address of equipment owner : Pacific Drilling
Address of premises where test / Examination was held: Pacific Bora
We hereby certify that on 03/08/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection. Fit for use Signature of Inspector: Conducting Examination Name of Inspector: OLATUNJI AKINLADE Conducting: Examination only
Revision No: 01
Doc No: JCI-C-V-01
JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: service@jcinternationalng.com Website: www.jcinternationalng.com
CERTIFICATE OF VISUAL EXAMINATION
STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998
Certificate No. 7426 Identification Number Qty
Date of Examination 03/08/2012
Examiner OLATUNJI AKINLADE TARE WT SWL
Qualifications LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Description of Equipment
Examination
FABRICATED PADEYE
SER- 10
1
A Steel Construction Fabricated Pad Eye / Anchor Point
N/A
2 tonnes
N/A
N/A
02/02/13
LOCATION: STBD SIDE ENGINE ROOM
SPECIFICATION: BS 2573 MPI METHOD: N/A PARTS EXAMINED: Entire body RESULTS: No defect as at the time of inspection. Fit for use TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A
Name and address of equipment owner : Pacific Drilling
Address of premises where test / Examination was held: Pacific Bora
We hereby certify that on 03/08/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection. Fit for use Signature of Inspector: Conducting Examination Name of Inspector: OLATUNJI AKINLADE Conducting: Examination only
Revision No: 01
Doc No: JCI-C-V-01
JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: service@jcinternationalng.com Website: www.jcinternationalng.com
CERTIFICATE OF VISUAL EXAMINATION
STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998
Certificate No. 7427 Identification Number Qty
Date of Examination 03/08/2012
Examiner OLATUNJI AKINLADE TARE WT SWL
Qualifications LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Description of Equipment
Examination
FABRICATED PADEYE
SER- 11
1
A Steel Construction Fabricated Pad Eye / Anchor Point
N/A
2 tonnes
N/A
N/A
02/02/13
LOCATION: STBD SIDE ENGINE ROOM
SPECIFICATION: BS 2573 MPI METHOD: N/A PARTS EXAMINED: Entire body RESULTS: No defect as at the time of inspection. Fit for use TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A
Name and address of equipment owner : Pacific Drilling
Address of premises where test / Examination was held: Pacific Bora
We hereby certify that on 03/08/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection. Fit for use Signature of Inspector: Conducting Examination Name of Inspector: OLATUNJI AKINLADE Conducting: Examination only
Revision No: 01
Doc No: JCI-C-V-01
JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: service@jcinternationalng.com Website: www.jcinternationalng.com
CERTIFICATE OF VISUAL EXAMINATION
STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998
Certificate No. 7428 Identification Number Qty
Date of Examination 03/08/2012
Examiner OLATUNJI AKINLADE TARE WT SWL
Qualifications LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Description of Equipment
Examination
FABRICATED PADEYE
SER- 12
1
A Steel Construction Fabricated Pad Eye / Anchor Point
N/A
2 tonnes
N/A
N/A
02/02/13
LOCATION: STBD SIDE ENGINE ROOM
SPECIFICATION: BS 2573 MPI METHOD: N/A PARTS EXAMINED: Entire body RESULTS: No defect as at the time of inspection. Fit for use TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A
Name and address of equipment owner : Pacific Drilling
Address of premises where test / Examination was held: Pacific Bora
We hereby certify that on 03/08/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection. Fit for use Signature of Inspector: Conducting Examination Name of Inspector: OLATUNJI AKINLADE Conducting: Examination only
Revision No: 01
Doc No: JCI-C-V-01
JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: service@jcinternationalng.com Website: www.jcinternationalng.com
CERTIFICATE OF VISUAL EXAMINATION
STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998
Certificate No. 7429 Identification Number Qty
Date of Examination 03/08/2012
Examiner OLATUNJI AKINLADE TARE WT SWL
Qualifications LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Description of Equipment
Examination
FABRICATED PADEYE
SER- 13
1
A Steel Construction Fabricated Pad Eye / Anchor Point
N/A
2 tonnes
N/A
N/A
02/02/13
LOCATION: STBD SIDE ENGINE ROOM
SPECIFICATION: BS 2573 MPI METHOD: N/A PARTS EXAMINED: Entire body RESULTS: No defect as at the time of inspection. Fit for use TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A
Name and address of equipment owner : Pacific Drilling
Address of premises where test / Examination was held: Pacific Bora
We hereby certify that on 03/08/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection. Fit for use Signature of Inspector: Conducting Examination Name of Inspector: OLATUNJI AKINLADE Conducting: Examination only
Revision No: 01
Doc No: JCI-C-V-01
JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: service@jcinternationalng.com Website: www.jcinternationalng.com
CERTIFICATE OF VISUAL EXAMINATION
STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998
Certificate No. 7430 Identification Number Qty
Date of Examination 03/08/2012
Examiner OLATUNJI AKINLADE TARE WT SWL
Qualifications LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Description of Equipment
Examination
FABRICATED PADEYE
SER- 14
1
A Steel Construction Fabricated Pad Eye / Anchor Point
N/A
2 tonnes
N/A
N/A
02/02/13
LOCATION: STBD SIDE ENGINE ROOM
SPECIFICATION: BS 2573 MPI METHOD: N/A PARTS EXAMINED: Entire body RESULTS: No defect as at the time of inspection. Fit for use TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A
Name and address of equipment owner : Pacific Drilling
Address of premises where test / Examination was held: Pacific Bora
We hereby certify that on 03/08/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection. Fit for use Signature of Inspector: Conducting Examination Name of Inspector: OLATUNJI AKINLADE Conducting: Examination only
Revision No: 01
Doc No: JCI-C-V-01
JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: service@jcinternationalng.com Website: www.jcinternationalng.com
CERTIFICATE OF VISUAL EXAMINATION
STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998
Certificate No. 7431 Identification Number Qty
Date of Examination 03/08/2012
Examiner OLATUNJI AKINLADE TARE WT SWL
Qualifications LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Description of Equipment
Examination
FABRICATED PADEYE
SER- 15
1
A Steel Construction Fabricated Pad Eye / Anchor Point
N/A
2 tonnes
N/A
N/A
02/02/13
LOCATION: STBD SIDE ENGINE ROOM
SPECIFICATION: BS 2573 MPI METHOD: N/A PARTS EXAMINED: Entire body RESULTS: No defect as at the time of inspection. Fit for use TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A
Name and address of equipment owner : Pacific Drilling
Address of premises where test / Examination was held: Pacific Bora
We hereby certify that on 03/08/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection. Fit for use Signature of Inspector: Conducting Examination Name of Inspector: OLATUNJI AKINLADE Conducting: Examination only
Revision No: 01
Doc No: JCI-C-V-01
JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: service@jcinternationalng.com Website: www.jcinternationalng.com
CERTIFICATE OF VISUAL EXAMINATION
STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998
Certificate No. 7432 Identification Number Qty
Date of Examination 03/08/2012
Examiner OLATUNJI AKINLADE TARE WT SWL
Qualifications LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Description of Equipment
Examination
FABRICATED PADEYE
SER- 16
1
A Steel Construction Fabricated Pad Eye / Anchor Point
N/A
2 tonnes
N/A
N/A
02/02/13
LOCATION: STBD SIDE ENGINE ROOM
SPECIFICATION: BS 2573 MPI METHOD: N/A PARTS EXAMINED: Entire body RESULTS: No defect as at the time of inspection. Fit for use TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A
Name and address of equipment owner: Pacific Drilling
Address of premises where test / Examination was held: Pacific Bora
We hereby certify that on 03/08/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection. Fit for use Signature of Inspector: Conducting Examination Name of Inspector: OLATUNJI AKINLADE Conducting: Examination only
Revision No: 01
Doc No: JCI-C-V-01
JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: service@jcinternationalng.com Website: www.jcinternationalng.com
CERTIFICATE OF VISUAL EXAMINATION
STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998
Certificate No. 7433 Identification Number Qty
Date of Examination 03/08/2012
Examiner OLATUNJI AKINLADE TARE WT SWL
Qualifications LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Description of Equipment
Examination
FABRICATED PADEYE
SER- 17
1
A Steel Construction Fabricated Pad Eye / Anchor Point
N/A
2 tonnes
N/A
N/A
02/02/13
LOCATION: STBD SIDE ENGINE ROOM
SPECIFICATION: BS 2573 MPI METHOD: N/A PARTS EXAMINED: Entire body RESULTS: No defect as at the time of inspection. Fit for use TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A
Name and address of equipment owner: Pacific Drilling
Address of premises where test / Examination was held: Pacific Bora
We hereby certify that on 03/08/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection. Fit for use Signature of Inspector: Conducting Examination Name of Inspector: OLATUNJI AKINLADE Conducting: Examination only
Revision No: 01
Doc No: JCI-C-V-01
JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: service@jcinternationalng.com Website: www.jcinternationalng.com
CERTIFICATE OF VISUAL EXAMINATION
STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998
Certificate No. 7434 Identification Number Qty
Date of Examination 03/08/2012
Examiner OLATUNJI AKINLADE TARE WT SWL
Qualifications LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Description of Equipment
Examination
FABRICATED PADEYE
SER- 18
1
A Steel Construction Fabricated Pad Eye / Anchor Point
N/A
2 tonnes
N/A
N/A
02/02/13
LOCATION: STBD SIDE ENGINE ROOM
SPECIFICATION: BS 2573 MPI METHOD: N/A PARTS EXAMINED: Entire body RESULTS: No defect as at the time of inspection. Fit for use TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A
Name and address of equipment owner : Pacific Drilling
Address of premises where test / Examination was held: Pacific Bora
We hereby certify that on 03/08/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection. Fit for use Signature of Inspector: Conducting Examination Name of Inspector: OLATUNJI AKINLADE Conducting: Examination only
Revision No: 01
Doc No: JCI-C-V-01
JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: service@jcinternationalng.com Website: www.jcinternationalng.com
CERTIFICATE OF VISUAL EXAMINATION
STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998
Certificate No. 7435 Identification Number Qty
Date of Examination 03/08/2012
Examiner OLATUNJI AKINLADE TARE WT SWL
Qualifications LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Description of Equipment
Examination
FABRICATED PADEYE
SER- 19
1
A Steel Construction Fabricated Pad Eye / Anchor Point
N/A
2 tonnes
N/A
N/A
02/02/13
LOCATION: STBD SIDE ENGINE ROOM
SPECIFICATION: BS 2573 MPI METHOD: N/A PARTS EXAMINED: Entire body RESULTS: No defect as at the time of inspection. Fit for use TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A
Name and address of equipment owner : Pacific Drilling
Address of premises where test / Examination was held: Pacific Bora
We hereby certify that on 03/08/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection. Fit for use Signature of Inspector: Conducting Examination Name of Inspector: OLATUNJI AKINLADE Conducting: Examination only
Revision No: 01
Doc No: JCI-C-V-01
JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: service@jcinternationalng.com Website: www.jcinternationalng.com
CERTIFICATE OF VISUAL EXAMINATION
STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998
Certificate No. 7436 Identification Number Qty
Date of Examination 03/08/2012
Examiner OLATUNJI AKINLADE TARE WT SWL
Qualifications LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Description of Equipment
Examination
FABRICATED PADEYE
SER- 20
1
A Steel Construction Fabricated Pad Eye / Anchor Point
N/A
2 tonnes
N/A
N/A
02/02/13
LOCATION: STBD SIDE ENGINE ROOM
SPECIFICATION: BS 2573 MPI METHOD: N/A PARTS EXAMINED: Entire body RESULTS: No defect as at the time of inspection. Fit for use TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A
Name and address of equipment owner : Pacific Drilling
Address of premises where test / Examination was held: Pacific Bora
We hereby certify that on 03/08/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection. Fit for use Signature of Inspector: Conducting Examination Name of Inspector: OLATUNJI AKINLADE Conducting: Examination only
Revision No: 01
Doc No: JCI-C-V-01
JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: service@jcinternationalng.com Website: www.jcinternationalng.com
CERTIFICATE OF VISUAL EXAMINATION
STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998
Certificate No. 7437 Identification Number Qty
Date of Examination 03/08/2012
Examiner OLATUNJI AKINLADE TARE WT SWL
Qualifications LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Description of Equipment
Examination
FABRICATED PADEYE
PER- 001
1
A Steel Construction Fabricated Pad Eye / Anchor Point
N/A
2 tonnes
N/A
N/A
02/02/13
LOCATION: PORT SIDE ENGINE ROOM
SPECIFICATION: BS 2573 MPI METHOD: N/A PARTS EXAMINED: Entire body RESULTS: No defect as at the time of inspection. Fit for use TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A
Name and address of equipment owner : Pacific Drilling
Address of premises where test / Examination was held: Pacific Bora
We hereby certify that on 03/08/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection. Fit for use Signature of Inspector: Conducting Examination Name of Inspector: OLATUNJI AKINLADE Conducting: Examination only
Revision No: 01
Doc No: JCI-C-V-01
JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: service@jcinternationalng.com Website: www.jcinternationalng.com
CERTIFICATE OF VISUAL EXAMINATION
STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998
Certificate No. 7438 Identification Number Qty
Date of Examination 03/08/2012
Examiner OLATUNJI AKINLADE TARE WT SWL
Qualifications LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Description of Equipment
Examination
FABRICATED PADEYE
PER- 002
1
A Steel Construction Fabricated Pad Eye / Anchor Point
N/A
2 tonnes
N/A
N/A
02/02/13
LOCATION: PORT SIDE ENGINE ROOM
SPECIFICATION: BS 2573 MPI METHOD: N/A PARTS EXAMINED: Entire body RESULTS: No defect as at the time of inspection. Fit for use TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A
Name and address of equipment owner : Pacific Drilling
Address of premises where test / Examination was held: Pacific Bora
We hereby certify that on 03/08/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection. Fit for use Signature of Inspector: Conducting Examination Name of Inspector: OLATUNJI AKINLADE Conducting: Examination only
Revision No: 01
Doc No: JCI-C-V-01
JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: service@jcinternationalng.com Website: www.jcinternationalng.com
CERTIFICATE OF VISUAL EXAMINATION
STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998
Certificate No. 7439 Identification Number Qty
Date of Examination 03/08/2012
Examiner OLATUNJI AKINLADE TARE WT SWL
Qualifications LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Description of Equipment
Examination
FABRICATED PADEYE
PER- 003
1
A Steel Construction Fabricated Pad Eye / Anchor Point
N/A
2 tonnes
N/A
N/A
02/02/13
LOCATION: PORT SIDE ENGINE ROOM
SPECIFICATION: BS 2573 MPI METHOD: N/A PARTS EXAMINED: Entire body RESULTS: No defect as at the time of inspection. Fit for use TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A
Name and address of equipment owner : Pacific Drilling
Address of premises where test / Examination was held: Pacific Bora
We hereby certify that on 03/08/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection. Fit for use Signature of Inspector: Conducting Examination Name of Inspector: OLATUNJI AKINLADE Conducting: Examination only
Revision No: 01
Doc No: JCI-C-V-01
JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: service@jcinternationalng.com Website: www.jcinternationalng.com
CERTIFICATE OF VISUAL EXAMINATION
STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998
Certificate No. 7440 Identification Number Qty
Date of Examination 03/08/2012
Examiner OLATUNJI AKINLADE TARE WT SWL
Qualifications LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Description of Equipment
Examination
FABRICATED PADEYE
PER- 004
1
A Steel Construction Fabricated Pad Eye / Anchor Point
N/A
2 tonnes
N/A
N/A
02/02/13
LOCATION: PORT SIDE ENGINE ROOM
SPECIFICATION: BS 2573 MPI METHOD: N/A PARTS EXAMINED: Entire body RESULTS: No defect as at the time of inspection. Fit for use TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A
Name and address of equipment owner : Pacific Drilling
Address of premises where test / Examination was held: Pacific Bora
We hereby certify that on 03/08/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection. Fit for use Signature of Inspector: Conducting Examination Name of Inspector: OLATUNJI AKINLADE Conducting: Examination only
Revision No: 01
Doc No: JCI-C-V-01
JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: service@jcinternationalng.com Website: www.jcinternationalng.com
CERTIFICATE OF VISUAL EXAMINATION
STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998
Certificate No. 7441 Identification Number Qty
Date of Examination 03/08/2012
Examiner OLATUNJI AKINLADE TARE WT SWL
Qualifications LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Description of Equipment
Examination
FABRICATED PADEYE
PER- 005
1
A Steel Construction Fabricated Pad Eye / Anchor Point
N/A
2 tonnes
N/A
N/A
02/02/13
LOCATION: PORT SIDE ENGINE ROOM
SPECIFICATION: BS 2573 MPI METHOD: N/A PARTS EXAMINED: Entire body RESULTS: No defect as at the time of inspection. Fit for use TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A
Name and address of equipment owner : Pacific Drilling
Address of premises where test / Examination was held: Pacific Bora
We hereby certify that on 03/08/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection. Fit for use Signature of Inspector: Conducting Examination Name of Inspector: OLATUNJI AKINLADE Conducting: Examination only
Revision No: 01
Doc No: JCI-C-V-01
JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: service@jcinternationalng.com Website: www.jcinternationalng.com
CERTIFICATE OF VISUAL EXAMINATION
STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998
Certificate No. 7442 Identification Number Qty
Date of Examination 03/08/2012
Examiner OLATUNJI AKINLADE TARE WT SWL
Qualifications LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Description of Equipment
Examination
FABRICATED PADEYE
PER- 006
1
A Steel Construction Fabricated Pad Eye / Anchor Point
N/A
2 tonnes
N/A
N/A
02/02/13
LOCATION: PORT SIDE ENGINE ROOM
SPECIFICATION: BS 2573 MPI METHOD: N/A PARTS EXAMINED: Entire body RESULTS: No defect as at the time of inspection. Fit for use TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A
Name and address of equipment owner : Pacific Drilling
Address of premises where test / Examination was held: Pacific Bora
We hereby certify that on 03/08/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection. Fit for use Signature of Inspector: Conducting Examination Name of Inspector: OLATUNJI AKINLADE Conducting: Examination only
Revision No: 01
Doc No: JCI-C-V-01
JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: service@jcinternationalng.com Website: www.jcinternationalng.com
CERTIFICATE OF VISUAL EXAMINATION
STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998
Certificate No. 7443 Identification Number Qty
Date of Examination 03/08/2012
Examiner OLATUNJI AKINLADE TARE WT SWL
Qualifications LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Description of Equipment
Examination
FABRICATED PADEYE
PER- 007
1
A Steel Construction Fabricated Pad Eye / Anchor Point
N/A
2 tonnes
N/A
N/A
02/02/13
LOCATION: PORT SIDE ENGINE ROOM
SPECIFICATION: BS 2573 MPI METHOD: N/A PARTS EXAMINED: Entire body RESULTS: No defect as at the time of inspection. Fit for use TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A
Name and address of equipment owner: Pacific Drilling
Address of premises where test / Examination was held: Pacific Bora
We hereby certify that on 03/08/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection. Fit for use Signature of Inspector: Conducting Examination Name of Inspector: OLATUNJI AKINLADE Conducting: Examination only
Revision No: 01
Doc No: JCI-C-V-01
JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: service@jcinternationalng.com Website: www.jcinternationalng.com
CERTIFICATE OF VISUAL EXAMINATION
STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998
Certificate No. 7444 Identification Number Qty
Date of Examination 03/08/2012
Examiner OLATUNJI AKINLADE TARE WT SWL
Qualifications LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Description of Equipment
Examination
FABRICATED PADEYE
PER- 008
1
A Steel Construction Fabricated Pad Eye / Anchor Point
N/A
2 tonnes
N/A
N/A
02/02/13
LOCATION: PORT SIDE ENGINE ROOM
SPECIFICATION: BS 2573 MPI METHOD: N/A PARTS EXAMINED: Entire body RESULTS: No defect as at the time of inspection. Fit for use TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A
Name and address of equipment owner : Pacific Drilling
Address of premises where test / Examination was held: Pacific Bora
We hereby certify that on 03/08/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection. Fit for use Signature of Inspector: Conducting Examination Name of Inspector: OLATUNJI AKINLADE Conducting: Examination only
Revision No: 01
Doc No: JCI-C-V-01
JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: service@jcinternationalng.com Website: www.jcinternationalng.com
CERTIFICATE OF VISUAL EXAMINATION
STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998
Certificate No. 7445 Identification Number Qty
Date of Examination 03/08/2012
Examiner OLATUNJI AKINLADE TARE WT SWL
Qualifications LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Description of Equipment
Examination
FABRICATED PADEYE
PER- 009
1
A Steel Construction Fabricated Pad Eye / Anchor Point
N/A
2 tonnes
N/A
N/A
02/02/13
LOCATION: PORT SIDE ENGINE ROOM
SPECIFICATION: BS 2573 MPI METHOD: N/A PARTS EXAMINED: Entire body RESULTS: No defect as at the time of inspection. Fit for use TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A
Name and address of equipment owner : Pacific Drilling
Address of premises where test / Examination was held: Pacific Bora
We hereby certify that on 03/08/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection. Fit for use Signature of Inspector: Conducting Examination Name of Inspector: OLATUNJI AKINLADE Conducting: Examination only
Revision No: 01
Doc No: JCI-C-V-01
JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: service@jcinternationalng.com Website: www.jcinternationalng.com
CERTIFICATE OF VISUAL EXAMINATION
STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998
Certificate No. 7446 Identification Number Qty
Date of Examination 03/08/2012
Examiner OLATUNJI AKINLADE TARE WT SWL
Qualifications LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Description of Equipment
Examination
FABRICATED PADEYE
PER- 10
1
A Steel Construction Fabricated Pad Eye / Anchor Point
N/A
2 tonnes
N/A
N/A
02/02/13
LOCATION: PORT SIDE ENGINE ROOM
SPECIFICATION: BS 2573 MPI METHOD: N/A PARTS EXAMINED: Entire body RESULTS: No defect as at the time of inspection. Fit for use TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A
Name and address of equipment owner : Pacific Drilling
Address of premises where test / Examination was held: Pacific Bora
We hereby certify that on 03/08/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection. Fit for use Signature of Inspector: Conducting Examination Name of Inspector: OLATUNJI AKINLADE Conducting: Examination only
Revision No: 01
Doc No: JCI-C-V-01
JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: service@jcinternationalng.com Website: www.jcinternationalng.com
CERTIFICATE OF VISUAL EXAMINATION
STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998
Certificate No. 7447 Identification Number Qty
Date of Examination 03/08/2012
Examiner OLATUNJI AKINLADE TARE WT SWL
Qualifications LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Description of Equipment
Examination
FABRICATED PADEYE
PER- 11
1
A Steel Construction Fabricated Pad Eye / Anchor Point
N/A
2 tonnes
N/A
N/A
02/02/13
LOCATION: PORT SIDE ENGINE ROOM
SPECIFICATION: BS 2573 MPI METHOD: N/A PARTS EXAMINED: Entire body RESULTS: No defect as at the time of inspection. Fit for use TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A
Name and address of equipment owner : Pacific Drilling
Address of premises where test / Examination was held: Pacific Bora
We hereby certify that on 03/08/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection. Fit for use Signature of Inspector: Conducting Examination Name of Inspector: OLATUNJI AKINLADE Conducting: Examination only
Revision No: 01
Doc No: JCI-C-V-01
JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: service@jcinternationalng.com Website: www.jcinternationalng.com
CERTIFICATE OF VISUAL EXAMINATION
STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998
Certificate No. 7448 Identification Number Qty
Date of Examination 03/08/2012
Examiner OLATUNJI AKINLADE TARE WT SWL
Qualifications LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Description of Equipment
Examination
FABRICATED PADEYE
PER- 12
1
A Steel Construction Fabricated Pad Eye / Anchor Point
N/A
2 tonnes
N/A
N/A
02/02/13
LOCATION: PORT SIDE ENGINE ROOM
SPECIFICATION: BS 2573 MPI METHOD: N/A PARTS EXAMINED: Entire body RESULTS: No defect as at the time of inspection. Fit for use TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A
Name and address of equipment owner : Pacific Drilling
Address of premises where test / Examination was held: Pacific Bora
We hereby certify that on 03/08/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection. Fit for use Signature of Inspector: Conducting Examination Name of Inspector: OLATUNJI AKINLADE Conducting: Examination only
Revision No: 01
Doc No: JCI-C-V-01
JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: service@jcinternationalng.com Website: www.jcinternationalng.com
CERTIFICATE OF VISUAL EXAMINATION
STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998
Certificate No. 7449 Identification Number Qty
Date of Examination 03/08/2012
Examiner OLATUNJI AKINLADE TARE WT SWL
Qualifications LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Description of Equipment
Examination
FABRICATED PADEYE
PER- 13
1
A Steel Construction Fabricated Pad Eye / Anchor Point
N/A
2 tonnes
N/A
N/A
02/02/13
LOCATION: PORT SIDE ENGINE ROOM
SPECIFICATION: BS 2573 MPI METHOD: N/A PARTS EXAMINED: Entire body RESULTS: No defect as at the time of inspection. Fit for use TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A
Name and address of equipment owner : Pacific Drilling
Address of premises where test / Examination was held: Pacific Bora
We hereby certify that on 03/08/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection. Fit for use Signature of Inspector: Conducting Examination Name of Inspector: OLATUNJI AKINLADE Conducting: Examination only
Revision No: 01
Doc No: JCI-C-V-01
JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: service@jcinternationalng.com Website: www.jcinternationalng.com
CERTIFICATE OF VISUAL EXAMINATION
STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998
Certificate No. 7450 Identification Number Qty
Date of Examination 03/08/2012
Examiner OLATUNJI AKINLADE TARE WT SWL
Qualifications LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Description of Equipment
Examination
FABRICATED PADEYE
PER- 14
1
A Steel Construction Fabricated Pad Eye / Anchor Point
N/A
2 tonnes
N/A
N/A
02/02/13
LOCATION: PORT SIDE ENGINE ROOM
SPECIFICATION: BS 2573 MPI METHOD: N/A PARTS EXAMINED: Entire body RESULTS: No defect as at the time of inspection. Fit for use TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A
Name and address of equipment owner : Pacific Drilling
Address of premises where test / Examination was held: Pacific Bora
We hereby certify that on 03/08/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection. Fit for use Signature of Inspector: Conducting Examination Name of Inspector: OLATUNJI AKINLADE Conducting: Examination only
Revision No: 01
Doc No: JCI-C-V-01
JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: service@jcinternationalng.com Website: www.jcinternationalng.com
CERTIFICATE OF VISUAL EXAMINATION
STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998
Certificate No. 7451 Identification Number Qty
Date of Examination 03/08/2012
Examiner OLATUNJI AKINLADE TARE WT SWL
Qualifications LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Description of Equipment
Examination
FABRICATED PADEYE
PER- 15
1
A Steel Construction Fabricated Pad Eye / Anchor Point
N/A
2 tonnes
N/A
N/A
02/02/13
LOCATION: PORT SIDE ENGINE ROOM
SPECIFICATION: BS 2573 MPI METHOD: N/A PARTS EXAMINED: Entire body RESULTS: No defect as at the time of inspection. Fit for use TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A
Name and address of equipment owner : Pacific Drilling
Address of premises where test / Examination was held: Pacific Bora
We hereby certify that on 03/08/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection. Fit for use Signature of Inspector: Conducting Examination Name of Inspector: OLATUNJI AKINLADE Conducting: Examination only
Revision No: 01
Doc No: JCI-C-V-01
JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: service@jcinternationalng.com Website: www.jcinternationalng.com
CERTIFICATE OF VISUAL EXAMINATION
STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998
Certificate No. 7452 Identification Number Qty
Date of Examination 03/08/2012
Examiner OLATUNJI AKINLADE TARE WT SWL
Qualifications LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Description of Equipment
Examination
FABRICATED PADEYE
PER- 16
1
A Steel Construction Fabricated Pad Eye / Anchor Point
N/A
2 tonnes
N/A
N/A
02/02/13
LOCATION: PORT SIDE ENGINE ROOM
SPECIFICATION: BS 2573 MPI METHOD: N/A PARTS EXAMINED: Entire body RESULTS: No defect as at the time of inspection. Fit for use TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A
Name and address of equipment owner : Pacific Drilling
Address of premises where test / Examination was held: Pacific Bora
We hereby certify that on 03/08/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection. Fit for use Signature of Inspector: Conducting Examination Name of Inspector: OLATUNJI AKINLADE Conducting: Examination only
Revision No: 01
Doc No: JCI-C-V-01
JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: service@jcinternationalng.com Website: www.jcinternationalng.com
CERTIFICATE OF VISUAL EXAMINATION
STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998
Certificate No. 7453 Identification Number Qty
Date of Examination 03/08/2012
Examiner OLATUNJI AKINLADE TARE WT SWL
Qualifications LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Description of Equipment
Examination
FABRICATED PADEYE
PER- 17
1
A Steel Construction Fabricated Pad Eye / Anchor Point
N/A
2 tonnes
N/A
N/A
02/02/13
LOCATION: PORT SIDE ENGINE ROOM
SPECIFICATION: BS 2573 MPI METHOD: N/A PARTS EXAMINED: Entire body RESULTS: No defect as at the time of inspection. Fit for use TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A
Name and address of equipment owner: Pacific Drilling
Address of premises where test / Examination was held: Pacific Bora
We hereby certify that on 03/08/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection. Fit for use Signature of Inspector: Conducting Examination Name of Inspector: OLATUNJI AKINLADE Conducting: Examination only
Revision No: 01
Doc No: JCI-C-V-01
JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: service@jcinternationalng.com Website: www.jcinternationalng.com
CERTIFICATE OF VISUAL EXAMINATION
STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998
Certificate No. 7454 Identification Number Qty
Date of Examination 03/08/2012
Examiner OLATUNJI AKINLADE TARE WT SWL
Qualifications LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Description of Equipment
Examination
FABRICATED PADEYE
PER- 18
1
A Steel Construction Fabricated Pad Eye / Anchor Point
N/A
2 tonnes
N/A
N/A
02/02/13
LOCATION: PORT SIDE ENGINE ROOM
SPECIFICATION: BS 2573 MPI METHOD: N/A PARTS EXAMINED: Entire body RESULTS: No defect as at the time of inspection. Fit for use TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A
Name and address of equipment owner: Pacific Drilling
Address of premises where test / Examination was held: Pacific Bora
We hereby certify that on 03/08/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection. Fit for use Signature of Inspector: Conducting Examination Name of Inspector: OLATUNJI AKINLADE Conducting: Examination only
Revision No: 01
Doc No: JCI-C-V-01
JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: service@jcinternationalng.com Website: www.jcinternationalng.com
CERTIFICATE OF VISUAL EXAMINATION
STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998
Certificate No. 7455 Identification Number Qty
Date of Examination 03/08/2012
Examiner OLATUNJI AKINLADE TARE WT SWL
Qualifications LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Description of Equipment
Examination
FABRICATED PADEYE
PER- 19
1
A Steel Construction Fabricated Pad Eye / Anchor Point
N/A
2 tonnes
N/A
N/A
02/02/13
LOCATION: PORT SIDE ENGINE ROOM
SPECIFICATION: BS 2573 MPI METHOD: N/A PARTS EXAMINED: Entire body RESULTS: No defect as at the time of inspection. Fit for use TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A
Name and address of equipment owner : Pacific Drilling
Address of premises where test / Examination was held: Pacific Bora
We hereby certify that on 03/08/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection. Fit for use Signature of Inspector: Conducting Examination Name of Inspector: OLATUNJI AKINLADE Conducting: Examination only
Revision No: 01
Doc No: JCI-C-V-01
JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: service@jcinternationalng.com Website: www.jcinternationalng.com
CERTIFICATE OF VISUAL EXAMINATION
STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998
Certificate No. 7456 Identification Number Qty
Date of Examination 03/08/2012
Examiner OLATUNJI AKINLADE TARE WT SWL
Qualifications LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Description of Equipment
Examination
FABRICATED PADEYE
PER- 20
1
A Steel Construction Fabricated Pad Eye / Anchor Point
N/A
2 tonnes
N/A
N/A
02/02/13
LOCATION: PORT SIDE ENGINE ROOM
SPECIFICATION: BS 2573 MPI METHOD: N/A PARTS EXAMINED: Entire body RESULTS: No defect as at the time of inspection. Fit for use TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A
Name and address of equipment owner : Pacific Drilling
Address of premises where test / Examination was held: Pacific Bora
We hereby certify that on 03/08/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection. Fit for use Signature of Inspector: Conducting Examination Name of Inspector: OLATUNJI AKINLADE Conducting: Examination only
Revision No: 01
Doc No: JCI-C-V-01
JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: service@jcinternationalng.com Website: www.jcinternationalng.com
CERTIFICATE OF VISUAL EXAMINATION
STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998
Certificate No. 7457 Identification Number Qty
Date of Examination 05/08/2012
Examiner OLATUNJI AKINLADE TARE WT SWL
Qualifications LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Description of Equipment
Examination
FABRICATED PADEYE
LR1-001
1
A Steel Construction Fabricated Pad Eye / Anchor Point
N/A
1 tonne
N/A
N/A
04/02/13
LOCATION: LIFE RAFT NO. 1 STATION
SPECIFICATION: BS 2573 MPI METHOD: N/A PARTS EXAMINED: Entire body RESULTS: No defect as at the time of inspection. Fit for use TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A
Name and address of equipment owner : Pacific Drilling
Address of premises where test / Examination was held: Pacific Bora
We hereby certify that on 05/08/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection. Fit for use Signature of Inspector: Conducting Examination Name of Inspector: OLATUNJI AKINLADE Conducting: Examination only
Revision No: 01
Doc No: JCI-C-V-01
JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: service@jcinternationalng.com Website: www.jcinternationalng.com
CERTIFICATE OF VISUAL EXAMINATION
STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998
Certificate No. 7458 Identification Number Qty
Date of Examination 05/08/2012
Examiner OLATUNJI AKINLADE TARE WT SWL
Qualifications LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Description of Equipment
Examination
FABRICATED PADEYE
LR1-002
1
A Steel Construction Fabricated Pad Eye / Anchor Point
N/A
1 tonne
N/A
N/A
04/02/13
LOCATION: LIFE RAFT NO. 1 STATION
SPECIFICATION: BS 2573 MPI METHOD: N/A PARTS EXAMINED: Entire body RESULTS: No defect as at the time of inspection. Fit for use TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A
Name and address of equipment owner : Pacific Drilling
Address of premises where test / Examination was held: Pacific Bora
We hereby certify that on 05/08/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection. Fit for use Signature of Inspector: Conducting Examination Name of Inspector: OLATUNJI AKINLADE Conducting: Examination only
Revision No: 01
Doc No: JCI-C-V-01
JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: service@jcinternationalng.com Website: www.jcinternationalng.com
CERTIFICATE OF VISUAL EXAMINATION
STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998
Certificate No. 7459 Identification Number Qty
Date of Examination 05/08/2012
Examiner OLATUNJI AKINLADE TARE WT SWL
Qualifications LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Description of Equipment
Examination
FABRICATED PADEYE
LR1-003
1
A Steel Construction Fabricated Pad Eye / Anchor Point
N/A
1 tonne
N/A
N/A
04/02/13
LOCATION: LIFE RAFT NO. 1 STATION
SPECIFICATION: BS 2573 MPI METHOD: N/A PARTS EXAMINED: Entire body RESULTS: No defect as at the time of inspection. Fit for use TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A
Name and address of equipment owner : Pacific Drilling
Address of premises where test / Examination was held: Pacific Bora
We hereby certify that on 05/08/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection. Fit for use Signature of Inspector: Conducting Examination Name of Inspector: OLATUNJI AKINLADE Conducting: Examination only
Revision No: 01
Doc No: JCI-C-V-01
JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: service@jcinternationalng.com Website: www.jcinternationalng.com
CERTIFICATE OF VISUAL EXAMINATION
STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998
Certificate No. 7460 Identification Number Qty
Date of Examination 05/08/2012
Examiner OLATUNJI AKINLADE TARE WT SWL
Qualifications LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Description of Equipment
Examination
FABRICATED PADEYE
LR1-004
1
A Steel Construction Fabricated Pad Eye / Anchor Point
N/A
1 tonne
N/A
N/A
04/02/13
LOCATION: LIFE RAFT NO. 1 STATION
SPECIFICATION: BS 2573 MPI METHOD: N/A PARTS EXAMINED: Entire body RESULTS: No defect as at the time of inspection. Fit for use TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A
Name and address of equipment owner : Pacific Drilling
Address of premises where test / Examination was held: Pacific Bora
We hereby certify that on 05/08/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection. Fit for use Signature of Inspector: Conducting Examination Name of Inspector: OLATUNJI AKINLADE Conducting: Examination only
Revision No: 01
Doc No: JCI-C-V-01
JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: service@jcinternationalng.com Website: www.jcinternationalng.com
CERTIFICATE OF VISUAL EXAMINATION
STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998
Certificate No. 7461 Identification Number Qty
Date of Examination 05/08/2012
Examiner OLATUNJI AKINLADE TARE WT SWL
Qualifications LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Description of Equipment
Examination
FABRICATED PADEYE
LR2-001
1
A Steel Construction Fabricated Pad Eye / Anchor Point
N/A
1 tonne
N/A
N/A
04/02/13
LOCATION: LIFE RAFT NO. 2 STATION
SPECIFICATION: BS 2573 MPI METHOD: N/A PARTS EXAMINED: Entire body RESULTS: No defect as at the time of inspection. Fit for use TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A
Name and address of equipment owner : Pacific Drilling
Address of premises where test / Examination was held: Pacific Bora
We hereby certify that on 05/08/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection. Fit for use Signature of Inspector: Conducting Examination Name of Inspector: OLATUNJI AKINLADE Conducting: Examination only
Revision No: 01
Doc No: JCI-C-V-01
JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: service@jcinternationalng.com Website: www.jcinternationalng.com
CERTIFICATE OF VISUAL EXAMINATION
STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998
Certificate No. 7462 Identification Number Qty
Date of Examination 05/08/2012
Examiner OLATUNJI AKINLADE TARE WT SWL
Qualifications LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Description of Equipment
Examination
FABRICATED PADEYE
LR2-002
1
A Steel Construction Fabricated Pad Eye / Anchor Point
N/A
1 tonne
N/A
N/A
04/02/13
LOCATION: LIFE RAFT NO. 2 STATION
SPECIFICATION: BS 2573 MPI METHOD: N/A PARTS EXAMINED: Entire body RESULTS: No defect as at the time of inspection. Fit for use TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A
Name and address of equipment owner : Pacific Drilling
Address of premises where test / Examination was held: Pacific Bora
We hereby certify that on 05/08/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection. Fit for use Signature of Inspector: Conducting Examination Name of Inspector: OLATUNJI AKINLADE Conducting: Examination only
Revision No: 01
Doc No: JCI-C-V-01
JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: service@jcinternationalng.com Website: www.jcinternationalng.com
CERTIFICATE OF VISUAL EXAMINATION
STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998
Certificate No. 7463 Identification Number Qty
Date of Examination 05/08/2012
Examiner OLATUNJI AKINLADE TARE WT SWL
Qualifications LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Description of Equipment
Examination
FABRICATED PADEYE
LR2-003
1
A Steel Construction Fabricated Pad Eye / Anchor Point
N/A
1 tonne
N/A
N/A
04/02/13
LOCATION: LIFE RAFT NO. 2 STATION
SPECIFICATION: BS 2573 MPI METHOD: N/A PARTS EXAMINED: Entire body RESULTS: No defect as at the time of inspection. Fit for use TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A
Name and address of equipment owner : Pacific Drilling
Address of premises where test / Examination was held: Pacific Bora
We hereby certify that on 05/08/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection. Fit for use Signature of Inspector: Conducting Examination Name of Inspector: OLATUNJI AKINLADE Conducting: Examination only
Revision No: 01
Doc No: JCI-C-V-01
JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: service@jcinternationalng.com Website: www.jcinternationalng.com
CERTIFICATE OF VISUAL EXAMINATION
STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998
Certificate No. 7464 Identification Number Qty
Date of Examination 05/08/2012
Examiner OLATUNJI AKINLADE TARE WT SWL
Qualifications LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Description of Equipment
Examination
FABRICATED PADEYE
LR2-004
1
A Steel Construction Fabricated Pad Eye / Anchor Point
N/A
1 tonne
N/A
N/A
04/02/13
LOCATION: LIFE RAFT NO. 2 STATION
SPECIFICATION: BS 2573 MPI METHOD: N/A PARTS EXAMINED: Entire body RESULTS: No defect as at the time of inspection. Fit for use TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A
Name and address of equipment owner: Pacific Drilling
Address of premises where test / Examination was held: Pacific Bora
We hereby certify that on 05/08/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection. Fit for use Signature of Inspector: Conducting Examination Name of Inspector: OLATUNJI AKINLADE Conducting: Examination only
Revision No: 01
Doc No: JCI-C-V-01
JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: service@jcinternationalng.com Website: www.jcinternationalng.com
CERTIFICATE OF VISUAL EXAMINATION
STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998
Certificate No. 7465 Identification Number Qty
Date of Examination 05/08/2012
Examiner OLATUNJI AKINLADE TARE WT SWL
Qualifications LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Description of Equipment
Examination
FABRICATED PADEYE
LR3-001
1
A Steel Construction Fabricated Pad Eye / Anchor Point
N/A
1 tonne
N/A
N/A
04/02/13
LOCATION: LIFE RAFT NO. 3 STATION
SPECIFICATION: BS 2573 MPI METHOD: N/A PARTS EXAMINED: Entire body RESULTS: No defect as at the time of inspection. Fit for use TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A
Name and address of equipment owner : Pacific Drilling
Address of premises where test / Examination was held: Pacific Bora
We hereby certify that on 05/08/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection. Fit for use Signature of Inspector: Conducting Examination Name of Inspector: OLATUNJI AKINLADE Conducting: Examination only
Revision No: 01
Doc No: JCI-C-V-01
JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: service@jcinternationalng.com Website: www.jcinternationalng.com
CERTIFICATE OF VISUAL EXAMINATION
STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998
Certificate No. 7466 Identification Number Qty
Date of Examination 05/08/2012
Examiner OLATUNJI AKINLADE TARE WT SWL
Qualifications LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Description of Equipment
Examination
FABRICATED PADEYE
LR3-002
1
A Steel Construction Fabricated Pad Eye / Anchor Point
N/A
1 tonne
N/A
N/A
04/02/13
LOCATION: LIFE RAFT NO.3 STATION
SPECIFICATION: BS 2573 MPI METHOD: N/A PARTS EXAMINED: Entire body RESULTS: No defect as at the time of inspection. Fit for use TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A
Name and address of equipment owner : Pacific Drilling
Address of premises where test / Examination was held: Pacific Bora
We hereby certify that on 05/08/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection. Fit for use Signature of Inspector: Conducting Examination Name of Inspector: OLATUNJI AKINLADE Conducting: Examination only
Revision No: 01
Doc No: JCI-C-V-01
JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: service@jcinternationalng.com Website: www.jcinternationalng.com
CERTIFICATE OF VISUAL EXAMINATION
STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998
Certificate No. 7467 Identification Number Qty
Date of Examination 05/08/2012
Examiner OLATUNJI AKINLADE TARE WT SWL
Qualifications LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Description of Equipment
Examination
FABRICATED PADEYE
LR3-003
1
A Steel Construction Fabricated Pad Eye / Anchor Point
N/A
1 tonne
N/A
N/A
04/02/13
LOCATION: LIFE RAFT NO. 3 STATION
SPECIFICATION: BS 2573 MPI METHOD: N/A PARTS EXAMINED: Entire body RESULTS: No defect as at the time of inspection. Fit for use TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A
Name and address of equipment owner : Pacific Drilling
Address of premises where test / Examination was held: Pacific Bora
We hereby certify that on 05/08/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection. Fit for use Signature of Inspector: Conducting Examination Name of Inspector: OLATUNJI AKINLADE Conducting: Examination only
Revision No: 01
Doc No: JCI-C-V-01
JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: service@jcinternationalng.com Website: www.jcinternationalng.com
CERTIFICATE OF VISUAL EXAMINATION
STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998
Certificate No. 7468 Identification Number Qty
Date of Examination 05/08/2012
Examiner OLATUNJI AKINLADE TARE WT SWL
Qualifications LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Description of Equipment
Examination
FABRICATED PADEYE
LR3-004
1
A Steel Construction Fabricated Pad Eye / Anchor Point
N/A
1 tonne
N/A
N/A
04/02/13
LOCATION: LIFE RAFT NO. 3 STATION
SPECIFICATION: BS 2573 MPI METHOD: N/A PARTS EXAMINED: Entire body RESULTS: No defect as at the time of inspection. Fit for use TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A
Name and address of equipment owner : Pacific Drilling
Address of premises where test / Examination was held: Pacific Bora
We hereby certify that on 05/08/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection. Fit for use Signature of Inspector: Conducting Examination Name of Inspector: OLATUNJI AKINLADE Conducting: Examination only
Revision No: 01
Doc No: JCI-C-V-01
JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: service@jcinternationalng.com Website: www.jcinternationalng.com
CERTIFICATE OF VISUAL EXAMINATION
STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998
Certificate No. 7469 Identification Number Qty
Date of Examination 05/08/2012
Examiner OLATUNJI AKINLADE TARE WT SWL
Qualifications LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Description of Equipment
Examination
FABRICATED PADEYE
LR4-001
1
A Steel Construction Fabricated Pad Eye / Anchor Point
N/A
1 tonne
N/A
N/A
04/02/13
LOCATION: LIFE RAFT NO. 4 STATION
SPECIFICATION: BS 2573 MPI METHOD: N/A PARTS EXAMINED: Entire body RESULTS: No defect as at the time of inspection. Fit for use TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A
Name and address of equipment owner : Pacific Drilling
Address of premises where test / Examination was held: Pacific Bora
We hereby certify that on 05/08/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection. Fit for use Signature of Inspector: Conducting Examination Name of Inspector: OLATUNJI AKINLADE Conducting: Examination only
Revision No: 01
Doc No: JCI-C-V-01
JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: service@jcinternationalng.com Website: www.jcinternationalng.com
CERTIFICATE OF VISUAL EXAMINATION
STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998
Certificate No. 7470 Identification Number Qty
Date of Examination 05/08/2012
Examiner OLATUNJI AKINLADE TARE WT SWL
Qualifications LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Description of Equipment
Examination
FABRICATED PADEYE
LR4-002
1
A Steel Construction Fabricated Pad Eye / Anchor Point
N/A
1 tonne
N/A
N/A
04/02/13
LOCATION: LIFE RAFT NO.4 STATION
SPECIFICATION: BS 2573 MPI METHOD: N/A PARTS EXAMINED: Entire body RESULTS: No defect as at the time of inspection. Fit for use TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A
Name and address of equipment owner : Pacific Drilling
Address of premises where test / Examination was held: Pacific Bora
We hereby certify that on 05/08/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection. Fit for use Signature of Inspector: Conducting Examination Name of Inspector: OLATUNJI AKINLADE Conducting: Examination only
Revision No: 01
Doc No: JCI-C-V-01
JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: service@jcinternationalng.com Website: www.jcinternationalng.com
CERTIFICATE OF VISUAL EXAMINATION
STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998
Certificate No. 7471 Identification Number Qty
Date of Examination 05/08/2012
Examiner OLATUNJI AKINLADE TARE WT SWL
Qualifications LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Description of Equipment
Examination
FABRICATED PADEYE
LR4-003
1
A Steel Construction Fabricated Pad Eye / Anchor Point
N/A
1 tonne
N/A
N/A
04/02/13
LOCATION: LIFE RAFT NO. 4 STATION
SPECIFICATION: BS 2573 MPI METHOD: N/A PARTS EXAMINED: Entire body RESULTS: No defect as at the time of inspection. Fit for use TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A
Name and address of equipment owner : Pacific Drilling
Address of premises where test / Examination was held: Pacific Bora
We hereby certify that on 05/08/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection. Fit for use Signature of Inspector: Conducting Examination Name of Inspector: OLATUNJI AKINLADE Conducting: Examination only
Revision No: 01
Doc No: JCI-C-V-01
JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: service@jcinternationalng.com Website: www.jcinternationalng.com
CERTIFICATE OF VISUAL EXAMINATION
STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998
Certificate No. 7472 Identification Number Qty
Date of Examination 05/08/2012
Examiner OLATUNJI AKINLADE TARE WT SWL
Qualifications LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Description of Equipment
Examination
FABRICATED PADEYE
LR4-004
1
A Steel Construction Fabricated Pad Eye / Anchor Point
N/A
1 tonne
N/A
N/A
04/02/13
LOCATION: LIFE RAFT NO. 4 STATION
SPECIFICATION: BS 2573 MPI METHOD: N/A PARTS EXAMINED: Entire body RESULTS: No defect as at the time of inspection. Fit for use TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A
Name and address of equipment owner : Pacific Drilling
Address of premises where test / Examination was held: Pacific Bora
We hereby certify that on 05/08/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection. Fit for use Signature of Inspector: Conducting Examination Name of Inspector: OLATUNJI AKINLADE Conducting: Examination only
Revision No: 01
Doc No: JCI-C-V-01
JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: service@jcinternationalng.com Website: www.jcinternationalng.com
CERTIFICATE OF VISUAL EXAMINATION
STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998
Certificate No. 7473 Identification Number Qty
Date of Examination 05/08/2012
Examiner OLATUNJI AKINLADE TARE WT SWL
Qualifications LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Description of Equipment
Examination
FABRICATED PADEYE
LR5-001
1
A Steel Construction Fabricated Pad Eye / Anchor Point
N/A
1 tonne
N/A
N/A
04/02/13
LOCATION: LIFE RAFT NO. 5 STATION
SPECIFICATION: BS 2573 MPI METHOD: N/A PARTS EXAMINED: Entire body RESULTS: No defect as at the time of inspection. Fit for use TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A
Name and address of equipment owner : Pacific Drilling
Address of premises where test / Examination was held: Pacific Bora
We hereby certify that on 05/08/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection. Fit for use Signature of Inspector: Conducting Examination Name of Inspector: OLATUNJI AKINLADE Conducting: Examination only
Revision No: 01
Doc No: JCI-C-V-01
JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: service@jcinternationalng.com Website: www.jcinternationalng.com
CERTIFICATE OF VISUAL EXAMINATION
STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998
Certificate No. 7474 Identification Number Qty
Date of Examination 05/08/2012
Examiner OLATUNJI AKINLADE TARE WT SWL
Qualifications LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Description of Equipment
Examination
FABRICATED PADEYE
LR6-001
1
A Steel Construction Fabricated Pad Eye / Anchor Point
N/A
1 tonne
N/A
N/A
04/02/13
LOCATION: LIFE RAFT NO. 6 STATION
SPECIFICATION: BS 2573 MPI METHOD: N/A PARTS EXAMINED: Entire body RESULTS: No defect as at the time of inspection. Fit for use TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A
Name and address of equipment owner: Pacific Drilling
Address of premises where test / Examination was held: Pacific Bora
We hereby certify that on 05/08/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection. Fit for use Signature of Inspector: Conducting Examination Name of Inspector: OLATUNJI AKINLADE Conducting: Examination only
Revision No: 01
Doc No: JCI-C-V-01
JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: service@jcinternationalng.com Website: www.jcinternationalng.com
CERTIFICATE OF VISUAL EXAMINATION
STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998
Certificate No. 7475 Identification Number Qty
Date of Examination 05/08/2012
Examiner OLATUNJI AKINLADE TARE WT SWL
Qualifications LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Description of Equipment
Examination
FABRICATED PADEYE
LR6-002
1
A Steel Construction Fabricated Pad Eye / Anchor Point
N/A
1 tonne
N/A
N/A
04/02/13
LOCATION: LIFE RAFT NO. 6 STATION
SPECIFICATION: BS 2573 MPI METHOD: N/A PARTS EXAMINED: Entire body RESULTS: No defect as at the time of inspection. Fit for use TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A
Name and address of equipment owner: Pacific Drilling
Address of premises where test / Examination was held: Pacific Bora
We hereby certify that on 05/08/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection. Fit for use Signature of Inspector: Conducting Examination Name of Inspector: OLATUNJI AKINLADE Conducting: Examination only
Revision No: 01
Doc No: JCI-C-V-01
JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: service@jcinternationalng.com Website: www.jcinternationalng.com
CERTIFICATE OF VISUAL EXAMINATION
STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998
Certificate No. 7476 Identification Number Qty
Date of Examination 05/08/2012
Examiner OLATUNJI AKINLADE TARE WT SWL
Qualifications LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Description of Equipment
Examination
FABRICATED PADEYE
LR6-003
1
A Steel Construction Fabricated Pad Eye / Anchor Point
N/A
1 tonne
N/A
N/A
04/02/13
LOCATION: LIFE RAFT NO. 6 STATION
SPECIFICATION: BS 2573 MPI METHOD: N/A PARTS EXAMINED: Entire body RESULTS: No defect as at the time of inspection. Fit for use TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A
Name and address of equipment owner : Pacific Drilling
Address of premises where test / Examination was held: Pacific Bora
We hereby certify that on 05/08/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection. Fit for use Signature of Inspector: Conducting Examination Name of Inspector: OLATUNJI AKINLADE Conducting: Examination only
Revision No: 01
Doc No: JCI-C-V-01
JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: service@jcinternationalng.com Website: www.jcinternationalng.com
CERTIFICATE OF VISUAL EXAMINATION
STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998
Certificate No. 7477 Identification Number Qty
Date of Examination 05/08/2012
Examiner OLATUNJI AKINLADE TARE WT SWL
Qualifications LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Description of Equipment
Examination
FABRICATED PADEYE
LR6-004
1
A Steel Construction Fabricated Pad Eye / Anchor Point
N/A
1 tonne
N/A
N/A
04/02/13
LOCATION: LIFE RAFT NO.6 STATION
SPECIFICATION: BS 2573 MPI METHOD: N/A PARTS EXAMINED: Entire body RESULTS: No defect as at the time of inspection. Fit for use TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A
Name and address of equipment owner : Pacific Drilling
Address of premises where test / Examination was held: Pacific Bora
We hereby certify that on 05/08/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection. Fit for use Signature of Inspector: Conducting Examination Name of Inspector: OLATUNJI AKINLADE Conducting: Examination only
Revision No: 01
Doc No: JCI-C-V-01
JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: service@jcinternationalng.com Website: www.jcinternationalng.com
CERTIFICATE OF VISUAL EXAMINATION
STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998
Certificate No. 7478 Identification Number Qty
Date of Examination 05/08/2012
Examiner OLATUNJI AKINLADE TARE WT SWL
Qualifications LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Description of Equipment
Examination
FABRICATED PADEYE
FC02-001
1
A Steel Construction Fabricated Pad Eye / Anchor Point
N/A
1 tonne
N/A
N/A
04/02/13
LOCATION: FWD CO2 BOTTLES ROOM
SPECIFICATION: BS 2573 MPI METHOD: N/A PARTS EXAMINED: Entire body RESULTS: No defect as at the time of inspection. Fit for use TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A
Name and address of equipment owner : Pacific Drilling
Address of premises where test / Examination was held: Pacific Bora
We hereby certify that on 05/08/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection. Fit for use Signature of Inspector: Conducting Examination Name of Inspector: OLATUNJI AKINLADE Conducting: Examination only
Revision No: 01
Doc No: JCI-C-V-01
JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: service@jcinternationalng.com Website: www.jcinternationalng.com
CERTIFICATE OF VISUAL EXAMINATION
STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998
Certificate No. 7479 Identification Number Qty
Date of Examination 05/08/2012
Examiner OLATUNJI AKINLADE TARE WT SWL
Qualifications LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Description of Equipment
Examination
FABRICATED PADEYE
FC02-002
1
A Steel Construction Fabricated Pad Eye / Anchor Point
N/A
1 tonne
N/A
N/A
04/02/13
LOCATION: FWD CO2 BOTTLES ROOM
SPECIFICATION: BS 2573 MPI METHOD: N/A PARTS EXAMINED: Entire body RESULTS: No defect as at the time of inspection. Fit for use TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A
Name and address of equipment owner : Pacific Drilling
Address of premises where test / Examination was held: Pacific Bora
We hereby certify that on 05/08/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection. Fit for use Signature of Inspector: Conducting Examination Name of Inspector: OLATUNJI AKINLADE Conducting: Examination only
Revision No: 01
Doc No: JCI-C-V-01
JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: service@jcinternationalng.com Website: www.jcinternationalng.com
CERTIFICATE OF VISUAL EXAMINATION
STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998
Certificate No. 7480 Identification Number Qty
Date of Examination 05/08/2012
Examiner OLATUNJI AKINLADE TARE WT SWL
Qualifications LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Description of Equipment
Examination
FABRICATED PADEYE
FC02-003
1
A Steel Construction Fabricated Pad Eye / Anchor Point
N/A
1 tonne
N/A
N/A
04/02/13
LOCATION: FWD CO2 BOTTLES ROOM
SPECIFICATION: BS 2573 MPI METHOD: N/A PARTS EXAMINED: Entire body RESULTS: No defect as at the time of inspection. Fit for use TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A
Name and address of equipment owner : Pacific Drilling
Address of premises where test / Examination was held: Pacific Bora
We hereby certify that on 05/08/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection. Fit for use Signature of Inspector: Conducting Examination Name of Inspector: OLATUNJI AKINLADE Conducting: Examination only
Revision No: 01
Doc No: JCI-C-V-01
JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: service@jcinternationalng.com Website: www.jcinternationalng.com
CERTIFICATE OF VISUAL EXAMINATION
STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998
Certificate No. 7481 Identification Number Qty
Date of Examination 05/08/2012
Examiner OLATUNJI AKINLADE TARE WT SWL
Qualifications LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Description of Equipment
Examination
FABRICATED PADEYE
FC02-004
1
A Steel Construction Fabricated Pad Eye / Anchor Point
N/A
1 tonne
N/A
N/A
04/02/13
LOCATION: FWD CO2 BOTTLES ROOM
SPECIFICATION: BS 2573 MPI METHOD: N/A PARTS EXAMINED: Entire body RESULTS: No defect as at the time of inspection. Fit for use TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A
Name and address of equipment owner : Pacific Drilling
Address of premises where test / Examination was held: Pacific Bora
We hereby certify that on 05/08/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection. Fit for use Signature of Inspector: Conducting Examination Name of Inspector: OLATUNJI AKINLADE Conducting: Examination only
Revision No: 01
Doc No: JCI-C-V-01
JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: service@jcinternationalng.com Website: www.jcinternationalng.com
CERTIFICATE OF VISUAL EXAMINATION
STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998
Certificate No. 7482 Identification Number Qty
Date of Examination 05/08/2012
Examiner OLATUNJI AKINLADE TARE WT SWL
Qualifications LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Description of Equipment
Examination
FABRICATED PADEYE
AC02-001
1
A Steel Construction Fabricated Pad Eye / Anchor Point
N/A
1 tonne
N/A
N/A
04/02/13
LOCATION: AFT CO2 BOTTLES ROOM
SPECIFICATION: BS 2573 MPI METHOD: N/A PARTS EXAMINED: Entire body RESULTS: No defect as at the time of inspection. Fit for use TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A
Name and address of equipment owner : Pacific Drilling
Address of premises where test / Examination was held: Pacific Bora
We hereby certify that on 05/08/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection. Fit for use Signature of Inspector: Conducting Examination Name of Inspector: OLATUNJI AKINLADE Conducting: Examination only
Revision No: 01
Doc No: JCI-C-V-01
JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: service@jcinternationalng.com Website: www.jcinternationalng.com
CERTIFICATE OF VISUAL EXAMINATION
STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998
Certificate No. 7483 Identification Number Qty
Date of Examination 05/08/2012
Examiner OLATUNJI AKINLADE TARE WT SWL
Qualifications LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Description of Equipment
Examination
FABRICATED PADEYE
AC02-002
1
A Steel Construction Fabricated Pad Eye / Anchor Point
N/A
1 tonne
N/A
N/A
04/02/13
LOCATION: AFT CO2 BOTTLES ROOM
SPECIFICATION: BS 2573 MPI METHOD: N/A PARTS EXAMINED: Entire body RESULTS: No defect as at the time of inspection. Fit for use TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A
Name and address of equipment owner : Pacific Drilling
Address of premises where test / Examination was held: Pacific Bora
We hereby certify that on 05/08/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection. Fit for use Signature of Inspector: Conducting Examination Name of Inspector: OLATUNJI AKINLADE Conducting: Examination only
Revision No: 01
Doc No: JCI-C-V-01
JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: service@jcinternationalng.com Website: www.jcinternationalng.com
CERTIFICATE OF VISUAL EXAMINATION
STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998
Certificate No. 7484 Identification Number Qty
Date of Examination 05/08/2012
Examiner OLATUNJI AKINLADE TARE WT SWL
Qualifications LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Description of Equipment
Examination
FABRICATED PADEYE
AC02-003
1
A Steel Construction Fabricated Pad Eye / Anchor Point
N/A
1 tonne
N/A
N/A
04/02/13
LOCATION: AFT CO2 BOTTLES ROOM
SPECIFICATION: BS 2573 MPI METHOD: N/A PARTS EXAMINED: Entire body RESULTS: No defect as at the time of inspection. Fit for use TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A
Name and address of equipment owner : Pacific Drilling
Address of premises where test / Examination was held: Pacific Bora
We hereby certify that on 05/08/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection. Fit for use Signature of Inspector: Conducting Examination Name of Inspector: OLATUNJI AKINLADE Conducting: Examination only
Revision No: 01
Doc No: JCI-C-V-01
JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: service@jcinternationalng.com Website: www.jcinternationalng.com
CERTIFICATE OF VISUAL EXAMINATION
STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998
Certificate No. 7485 Identification Number Qty
Date of Examination 05/08/2012
Examiner OLATUNJI AKINLADE TARE WT SWL
Qualifications LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Description of Equipment
Examination
FABRICATED PADEYE
AC02-004
1
A Steel Construction Fabricated Pad Eye / Anchor Point
N/A
1 tonne
N/A
N/A
04/02/13
LOCATION: AFT CO2 BOTTLES ROOM
SPECIFICATION: BS 2573 MPI METHOD: N/A PARTS EXAMINED: Entire body RESULTS: No defect as at the time of inspection. Fit for use TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A
Name and address of equipment owner: Pacific Drilling
Address of premises where test / Examination was held: Pacific Bora
We hereby certify that on 05/08/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection. Fit for use Signature of Inspector: Conducting Examination Name of Inspector: OLATUNJI AKINLADE Conducting: Examination only
Revision No: 01
Doc No: JCI-C-V-01
JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: service@jcinternationalng.com Website: www.jcinternationalng.com
CERTIFICATE OF VISUAL EXAMINATION
STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998
Certificate No. 7486 Identification Number Qty
Date of Examination 05/08/2012
Examiner OLATUNJI AKINLADE TARE WT SWL
Qualifications LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Description of Equipment
Examination
FABRICATED PADEYE
AC02-005
1
A Steel Construction Fabricated Pad Eye / Anchor Point
N/A
1 tonne
N/A
N/A
04/02/13
LOCATION: AFT CO2 BOTTLES ROOM
SPECIFICATION: BS 2573 MPI METHOD: N/A PARTS EXAMINED: Entire body RESULTS: No defect as at the time of inspection. Fit for use TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A
Name and address of equipment owner: Pacific Drilling
Address of premises where test / Examination was held: Pacific Bora
We hereby certify that on 05/08/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection. Fit for use Signature of Inspector: Conducting Examination Name of Inspector: OLATUNJI AKINLADE Conducting: Examination only
Revision No: 01
Doc No: JCI-C-V-01
JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: service@jcinternationalng.com Website: www.jcinternationalng.com
CERTIFICATE OF VISUAL EXAMINATION
STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998
Certificate No. 7487 Identification Number Qty
Date of Examination 05/08/2012
Examiner OLATUNJI AKINLADE TARE WT SWL
Qualifications LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Description of Equipment
Examination
FABRICATED PADEYE
AC02-006
1
A Steel Construction Fabricated Pad Eye / Anchor Point
N/A
1 tonne
N/A
N/A
04/02/13
LOCATION: AFT CO2 BOTTLES ROOM
SPECIFICATION: BS 2573 MPI METHOD: N/A PARTS EXAMINED: Entire body RESULTS: No defect as at the time of inspection. Fit for use TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A
Name and address of equipment owner : Pacific Drilling
Address of premises where test / Examination was held: Pacific Bora
We hereby certify that on 05/08/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection. Fit for use Signature of Inspector: Conducting Examination Name of Inspector: OLATUNJI AKINLADE Conducting: Examination only
Revision No: 01
Doc No: JCI-C-V-01
JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: service@jcinternationalng.com Website: www.jcinternationalng.com
CERTIFICATE OF VISUAL EXAMINATION
STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998
Certificate No. 7488 Identification Number Qty
Date of Examination 05/08/2012
Examiner OLATUNJI AKINLADE TARE WT SWL
Qualifications LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Description of Equipment
Examination
FABRICATED PADEYE
AC02-007
1
A Steel Construction Fabricated Pad Eye / Anchor Point
N/A
1 tonne
N/A
N/A
04/02/13
LOCATION: AFT CO2 BOTTLES ROOM
SPECIFICATION: BS 2573 MPI METHOD: N/A PARTS EXAMINED: Entire body RESULTS: No defect as at the time of inspection. Fit for use TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A
Name and address of equipment owner : Pacific Drilling
Address of premises where test / Examination was held: Pacific Bora
We hereby certify that on 05/08/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection. Fit for use Signature of Inspector: Conducting Examination Name of Inspector: OLATUNJI AKINLADE Conducting: Examination only
Revision No: 01
Doc No: JCI-C-V-01
JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: service@jcinternationalng.com Website: www.jcinternationalng.com
CERTIFICATE OF VISUAL EXAMINATION
STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998
Certificate No. 7489 Identification Number Qty
Date of Examination 05/08/2012
Examiner OLATUNJI AKINLADE TARE WT SWL
Qualifications LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Description of Equipment
Examination
FABRICATED PADEYE
AC02-008
1
A Steel Construction Fabricated Pad Eye / Anchor Point
N/A
1 tonne
N/A
N/A
04/02/13
LOCATION: AFT CO2 BOTTLES ROOM
SPECIFICATION: BS 2573 MPI METHOD: N/A PARTS EXAMINED: Entire body RESULTS: No defect as at the time of inspection. Fit for use TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A
Name and address of equipment owner : Pacific Drilling
Address of premises where test / Examination was held: Pacific Bora
We hereby certify that on 05/08/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection. Fit for use Signature of Inspector: Conducting Examination Name of Inspector: OLATUNJI AKINLADE Conducting: Examination only
Revision No: 01
Doc No: JCI-C-V-01
JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: service@jcinternationalng.com Website: www.jcinternationalng.com
CERTIFICATE OF VISUAL EXAMINATION
STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998
Certificate No. 7490 Identification Number Qty
Date of Examination 05/08/2012
Examiner OLATUNJI AKINLADE TARE WT SWL
Qualifications LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Description of Equipment
Examination
FABRICATED PADEYE
AC02-009
1
A Steel Construction Fabricated Pad Eye / Anchor Point
N/A
1 tonne
N/A
N/A
04/02/13
LOCATION: AFT CO2 BOTTLES ROOM
SPECIFICATION: BS 2573 MPI METHOD: N/A PARTS EXAMINED: Entire body RESULTS: No defect as at the time of inspection. Fit for use TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A
Name and address of equipment owner : Pacific Drilling
Address of premises where test / Examination was held: Pacific Bora
We hereby certify that on 05/08/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection. Fit for use Signature of Inspector: Conducting Examination Name of Inspector: OLATUNJI AKINLADE Conducting: Examination only
Revision No: 01
Doc No: JCI-C-V-01
JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: service@jcinternationalng.com Website: www.jcinternationalng.com
CERTIFICATE OF VISUAL EXAMINATION
STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998
Certificate No. 7491 Identification Number Qty
Date of Examination 05/08/2012
Examiner OLATUNJI AKINLADE TARE WT SWL
Qualifications LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Description of Equipment
Examination
FABRICATED PADEYE
AC02-010
1
A Steel Construction Fabricated Pad Eye / Anchor Point
N/A
1 tonne
N/A
N/A
04/02/13
LOCATION: AFT CO2 BOTTLES ROOM
SPECIFICATION: BS 2573 MPI METHOD: N/A PARTS EXAMINED: Entire body RESULTS: No defect as at the time of inspection. Fit for use TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A
Name and address of equipment owner : Pacific Drilling
Address of premises where test / Examination was held: Pacific Bora
We hereby certify that on 05/08/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection. Fit for use Signature of Inspector: Conducting Examination Name of Inspector: OLATUNJI AKINLADE Conducting: Examination only
Revision No: 01
Doc No: JCI-C-V-01
JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: service@jcinternationalng.com Website: www.jcinternationalng.com
CERTIFICATE OF VISUAL EXAMINATION
STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998
Certificate No. 7492 Identification Number Qty
Date of Examination 05/08/2012
Examiner OLATUNJI AKINLADE TARE WT SWL
Qualifications LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Description of Equipment
Examination
FABRICATED PADEYE
AC02-011
1
A Steel Construction Fabricated Pad Eye / Anchor Point
N/A
1 tonne
N/A
N/A
04/02/13
LOCATION: AFT CO2 BOTTLES ROOM
SPECIFICATION: BS 2573 MPI METHOD: N/A PARTS EXAMINED: Entire body RESULTS: No defect as at the time of inspection. Fit for use TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A
Name and address of equipment owner : Pacific Drilling
Address of premises where test / Examination was held: Pacific Bora
We hereby certify that on 05/08/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection. Fit for use Signature of Inspector: Conducting Examination Name of Inspector: OLATUNJI AKINLADE Conducting: Examination only
Revision No: 01
Doc No: JCI-C-V-01
JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: service@jcinternationalng.com Website: www.jcinternationalng.com
CERTIFICATE OF VISUAL EXAMINATION
STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998
Certificate No. 7493 Identification Number Qty
Date of Examination 05/08/2012
Examiner OLATUNJI AKINLADE TARE WT SWL
Qualifications LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Description of Equipment
Examination
FABRICATED PADEYE
AC02-012
1
A Steel Construction Fabricated Pad Eye / Anchor Point
N/A
1 tonne
N/A
N/A
04/02/13
LOCATION: AFT CO2 BOTTLES ROOM
SPECIFICATION: BS 2573 MPI METHOD: N/A PARTS EXAMINED: Entire body RESULTS: No defect as at the time of inspection. Fit for use TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A
Name and address of equipment owner : Pacific Drilling
Address of premises where test / Examination was held: Pacific Bora
We hereby certify that on 05/08/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection. Fit for use Signature of Inspector: Conducting Examination Name of Inspector: OLATUNJI AKINLADE Conducting: Examination only
Revision No: 01
Doc No: JCI-C-V-01
JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: service@jcinternationalng.com Website: www.jcinternationalng.com
CERTIFICATE OF VISUAL EXAMINATION
STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998
Certificate No. 7494 Identification Number Qty
Date of Examination 05/08/2012
Examiner OLATUNJI AKINLADE TARE WT SWL
Qualifications LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Description of Equipment
Examination
FABRICATED PADEYE
AC02-013
1
A Steel Construction Fabricated Pad Eye / Anchor Point
N/A
1 tonne
N/A
N/A
04/02/13
LOCATION: AFT CO2 BOTTLES ROOM
SPECIFICATION: BS 2573 MPI METHOD: N/A PARTS EXAMINED: Entire body RESULTS: No defect as at the time of inspection. Fit for use TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A
Name and address of equipment owner : Pacific Drilling
Address of premises where test / Examination was held: Pacific Bora
We hereby certify that on 05/08/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection. Fit for use Signature of Inspector: Conducting Examination Name of Inspector: OLATUNJI AKINLADE Conducting: Examination only
Revision No: 01
Doc No: JCI-C-V-01
JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: service@jcinternationalng.com Website: www.jcinternationalng.com
CERTIFICATE OF VISUAL EXAMINATION
STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998
Certificate No. 7495 Identification Number Qty
Date of Examination 05/08/2012
Examiner OLATUNJI AKINLADE TARE WT SWL
Qualifications LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Description of Equipment
Examination
FABRICATED PADEYE
AC02-014
1
A Steel Construction Fabricated Pad Eye / Anchor Point
N/A
1 tonne
N/A
N/A
04/02/13
LOCATION: AFT CO2 BOTTLES ROOM
SPECIFICATION: BS 2573 MPI METHOD: N/A PARTS EXAMINED: Entire body RESULTS: No defect as at the time of inspection. Fit for use TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A
Name and address of equipment owner : Pacific Drilling
Address of premises where test / Examination was held: Pacific Bora
We hereby certify that on 05/08/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection. Fit for use Signature of Inspector: Conducting Examination Name of Inspector: OLATUNJI AKINLADE Conducting: Examination only
Revision No: 01
Doc No: JCI-C-V-01
JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: service@jcinternationalng.com Website: www.jcinternationalng.com
CERTIFICATE OF VISUAL EXAMINATION
STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998
Certificate No. 7496 Identification Number Qty
Date of Examination 05/08/2012
Examiner OLATUNJI AKINLADE TARE WT SWL
Qualifications LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Description of Equipment
Examination
FABRICATED PADEYE
AC02-015
1
A Steel Construction Fabricated Pad Eye / Anchor Point
N/A
1 tonne
N/A
N/A
04/02/13
LOCATION: AFT CO2 BOTTLES ROOM
SPECIFICATION: BS 2573 MPI METHOD: N/A PARTS EXAMINED: Entire body RESULTS: No defect as at the time of inspection. Fit for use TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A
Name and address of equipment owner : Pacific Drilling
Address of premises where test / Examination was held: Pacific Bora
We hereby certify that on 05/08/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection. Fit for use Signature of Inspector: Conducting Examination Name of Inspector: OLATUNJI AKINLADE Conducting: Examination only
Revision No: 01
Doc No: JCI-C-V-01
JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: service@jcinternationalng.com Website: www.jcinternationalng.com
CERTIFICATE OF VISUAL EXAMINATION
STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998
Certificate No. 7497 Identification Number Qty
Date of Examination 05/08/2012
Examiner OLATUNJI AKINLADE TARE WT SWL
Qualifications LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Description of Equipment
Examination
FABRICATED PADEYE
AC02-016
1
A Steel Construction Fabricated Pad Eye / Anchor Point
N/A
1 tonne
N/A
N/A
04/02/13
LOCATION: AFT CO2 BOTTLES ROOM
SPECIFICATION: BS 2573 MPI METHOD: N/A PARTS EXAMINED: Entire body RESULTS: No defect as at the time of inspection. Fit for use TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A
Name and address of equipment owner: Pacific Drilling
Address of premises where test / Examination was held: Pacific Bora
We hereby certify that on 05/08/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection. Fit for use Signature of Inspector: Conducting Examination Name of Inspector: OLATUNJI AKINLADE Conducting: Examination only
Revision No: 01
Doc No: JCI-C-V-01
JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: service@jcinternationalng.com Website: www.jcinternationalng.com
CERTIFICATE OF VISUAL EXAMINATION
STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998
Certificate No. 7498 Identification Number Qty
Date of Examination 05/08/2012
Examiner OLATUNJI AKINLADE TARE WT SWL
Qualifications LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Description of Equipment
Examination
FABRICATED PADEYE
AC02-017
1
A Steel Construction Fabricated Pad Eye / Anchor Point
N/A
1 tonne
N/A
N/A
04/02/13
LOCATION: AFT CO2 BOTTLES ROOM
SPECIFICATION: BS 2573 MPI METHOD: N/A PARTS EXAMINED: Entire body RESULTS: No defect as at the time of inspection. Fit for use TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A
Name and address of equipment owner : Pacific Drilling
Address of premises where test / Examination was held: Pacific Bora
We hereby certify that on 05/08/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection. Fit for use Signature of Inspector: Conducting Examination Name of Inspector: OLATUNJI AKINLADE Conducting: Examination only
Revision No: 01
Doc No: JCI-C-V-01
JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: service@jcinternationalng.com Website: www.jcinternationalng.com
CERTIFICATE OF VISUAL EXAMINATION
STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998
Certificate No. 7499 Identification Number Qty
Date of Examination 05/08/2012
Examiner OLATUNJI AKINLADE TARE WT SWL
Qualifications LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Description of Equipment
Examination
FABRICATED PADEYE
AC02-018
1
A Steel Construction Fabricated Pad Eye / Anchor Point
N/A
1 tonne
N/A
N/A
04/02/13
LOCATION: AFT CO2 BOTTLES ROOM
SPECIFICATION: BS 2573 MPI METHOD: N/A PARTS EXAMINED: Entire body RESULTS: No defect as at the time of inspection. Fit for use TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A
Name and address of equipment owner : Pacific Drilling
Address of premises where test / Examination was held: Pacific Bora
We hereby certify that on 05/08/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection. Fit for use Signature of Inspector: Conducting Examination Name of Inspector: OLATUNJI AKINLADE Conducting: Examination only
Revision No: 01
Doc No: JCI-C-V-01
JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: service@jcinternationalng.com Website: www.jcinternationalng.com
CERTIFICATE OF VISUAL EXAMINATION
STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998
Certificate No. 7500 Identification Number Qty
Date of Examination 05/08/2012
Examiner OLATUNJI AKINLADE TARE WT SWL
Qualifications LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Description of Equipment
Examination
FABRICATED PADEYE
AC02-019
1
A Steel Construction Fabricated Pad Eye / Anchor Point
N/A
1 tonne
N/A
N/A
04/02/13
LOCATION: AFT CO2 BOTTLES ROOM
SPECIFICATION: BS 2573 MPI METHOD: N/A PARTS EXAMINED: Entire body RESULTS: No defect as at the time of inspection. Fit for use TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A
Name and address of equipment owner : Pacific Drilling
Address of premises where test / Examination was held: Pacific Bora
We hereby certify that on 05/08/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection. Fit for use Signature of Inspector: Conducting Examination Name of Inspector: OLATUNJI AKINLADE Conducting: Examination only
Revision No: 01
Doc No: JCI-C-V-01
JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: service@jcinternationalng.com Website: www.jcinternationalng.com
CERTIFICATE OF VISUAL EXAMINATION
STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998
Certificate No. 7501 Identification Number Qty
Date of Examination 05/08/2012
Examiner OLATUNJI AKINLADE TARE WT SWL
Qualifications LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Description of Equipment
Examination
FABRICATED PADEYE
AC02-020
1
A Steel Construction Fabricated Pad Eye / Anchor Point
N/A
1 tonne
N/A
N/A
04/02/13
LOCATION: AFT CO2 BOTTLES ROOM
SPECIFICATION: BS 2573 MPI METHOD: N/A PARTS EXAMINED: Entire body RESULTS: No defect as at the time of inspection. Fit for use TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A
Name and address of equipment owner : Pacific Drilling
Address of premises where test / Examination was held: Pacific Bora
We hereby certify that on 05/08/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection. Fit for use Signature of Inspector: Conducting Examination Name of Inspector: OLATUNJI AKINLADE Conducting: Examination only
Revision No: 01
Doc No: JCI-C-V-01
JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: service@jcinternationalng.com Website: www.jcinternationalng.com
CERTIFICATE OF VISUAL EXAMINATION
STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998
Certificate No. 7502 Identification Number Qty
Date of Examination 05/08/2012
Examiner OLATUNJI AKINLADE TARE WT SWL
Qualifications LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Description of Equipment
Examination
FABRICATED PADEYE
AC02-021
1
A Steel Construction Fabricated Pad Eye / Anchor Point
N/A
1 tonne
N/A
N/A
04/02/13
LOCATION: AFT CO2 BOTTLES ROOM
SPECIFICATION: BS 2573 MPI METHOD: N/A PARTS EXAMINED: Entire body RESULTS: No defect as at the time of inspection. Fit for use TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A
Name and address of equipment owner : Pacific Drilling
Address of premises where test / Examination was held: Pacific Bora
We hereby certify that on 05/08/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection. Fit for use Signature of Inspector: Conducting Examination Name of Inspector: OLATUNJI AKINLADE Conducting: Examination only
Revision No: 01
Doc No: JCI-C-V-01
JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: service@jcinternationalng.com Website: www.jcinternationalng.com
CERTIFICATE OF VISUAL EXAMINATION
STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998
Certificate No. 7503 Identification Number Qty
Date of Examination 05/08/2012
Examiner OLATUNJI AKINLADE TARE WT SWL
Qualifications LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Description of Equipment
Examination
FABRICATED PADEYE
AC02-022
1
A Steel Construction Fabricated Pad Eye / Anchor Point
N/A
1 tonne
N/A
N/A
04/02/13
LOCATION: AFT CO2 BOTTLES ROOM
SPECIFICATION: BS 2573 MPI METHOD: N/A PARTS EXAMINED: Entire body RESULTS: No defect as at the time of inspection. Fit for use TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A
Name and address of equipment owner : Pacific Drilling
Address of premises where test / Examination was held: Pacific Bora
We hereby certify that on 05/08/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection. Fit for use Signature of Inspector: Conducting Examination Name of Inspector: OLATUNJI AKINLADE Conducting: Examination only
Revision No: 01
Doc No: JCI-C-V-01
JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: service@jcinternationalng.com Website: www.jcinternationalng.com
CERTIFICATE OF VISUAL EXAMINATION
STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998
Certificate No. 7504 Identification Number Qty
Date of Examination 05/08/2012
Examiner OLATUNJI AKINLADE TARE WT SWL
Qualifications LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Description of Equipment
Examination
FABRICATED PADEYE
AC02-023
1
A Steel Construction Fabricated Pad Eye / Anchor Point
N/A
1 tonne
N/A
N/A
04/02/13
LOCATION: AFT CO2 BOTTLES ROOM
SPECIFICATION: BS 2573 MPI METHOD: N/A PARTS EXAMINED: Entire body RESULTS: No defect as at the time of inspection. Fit for use TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A
Name and address of equipment owner : Pacific Drilling
Address of premises where test / Examination was held: Pacific Bora
We hereby certify that on 05/08/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection. Fit for use Signature of Inspector: Conducting Examination Name of Inspector: OLATUNJI AKINLADE Conducting: Examination only
Revision No: 01
Doc No: JCI-C-V-01
JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: service@jcinternationalng.com Website: www.jcinternationalng.com
CERTIFICATE OF VISUAL EXAMINATION
STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998
Certificate No. 7505 Identification Number Qty
Date of Examination 06/08/2012
Examiner OLATUNJI AKINLADE TARE WT SWL
Qualifications LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Description of Equipment
Examination
FABRICATED PADEYE
BS-001
1
A Steel Construction Fabricated Pad Eye / Anchor Point
N/A
3 tonnes
N/A
N/A
05/02/13
LOCATION: BOSUN STORE
SPECIFICATION: BS 2573 MPI METHOD: N/A PARTS EXAMINED: Entire body RESULTS: No defect as at the time of inspection. Fit for use TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A
Name and address of equipment owner : Pacific Drilling
Address of premises where test / Examination was held: Pacific Bora
We hereby certify that on 06/08/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection. Fit for use Signature of Inspector: Conducting Examination Name of Inspector: OLATUNJI AKINLADE Conducting: Examination only
Revision No: 01
Doc No: JCI-C-V-01
JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: service@jcinternationalng.com Website: www.jcinternationalng.com
CERTIFICATE OF VISUAL EXAMINATION
STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998
Certificate No. 7506 Identification Number Qty
Date of Examination 06/08/2012
Examiner OLATUNJI AKINLADE TARE WT SWL
Qualifications LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Description of Equipment
Examination
FABRICATED PADEYE
BS-002
1
A Steel Construction Fabricated Pad Eye / Anchor Point
N/A
3 tonnes
N/A
N/A
05/02/13
LOCATION: BOSUN STORE
SPECIFICATION: BS 2573 MPI METHOD: N/A PARTS EXAMINED: Entire body RESULTS: No defect as at the time of inspection. Fit for use TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A
Name and address of equipment owner : Pacific Drilling
Address of premises where test / Examination was held: Pacific Bora
We hereby certify that on 06/08/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection. Fit for use Signature of Inspector: Conducting Examination Name of Inspector: OLATUNJI AKINLADE Conducting: Examination only
Revision No: 01
Doc No: JCI-C-V-01
JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: service@jcinternationalng.com Website: www.jcinternationalng.com
CERTIFICATE OF VISUAL EXAMINATION
STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998
Certificate No. 7507 Identification Number Qty
Date of Examination 07/08/2012
Examiner OLATUNJI AKINLADE TARE WT SWL
Qualifications LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Description of Equipment
Examination
FABRICATED PADEYE
MPR 01
1
A Steel Construction Fabricated Pad Eye / Anchor Point
N/A
2 tonnes
N/A
N/A
06/02/13
LOCATION: MUD PUMP ROOM
SPECIFICATION: BS 2573 MPI METHOD: N/A PARTS EXAMINED: Entire body RESULTS: No defect as at the time of inspection. Fit for use TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A
Name and address of equipment owner : Pacific Drilling
Address of premises where test / Examination was held: Pacific Bora
We hereby certify that on 07/08/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection. Fit for use Signature of Inspector: Conducting Examination Name of Inspector: OLATUNJI AKINLADE Conducting: Examination only
Revision No: 01
Doc No: JCI-C-V-01
JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: service@jcinternationalng.com Website: www.jcinternationalng.com
CERTIFICATE OF VISUAL EXAMINATION
STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998
Certificate No. 7508 Identification Number Qty
Date of Examination 07/08/2012
Examiner OLATUNJI AKINLADE TARE WT SWL
Qualifications LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Description of Equipment
Examination
FABRICATED PADEYE
MPR 02
1
A Steel Construction Fabricated Pad Eye / Anchor Point
N/A
2 tonnes
N/A
N/A
06/02/13
LOCATION: MUD PUMP ROOM
SPECIFICATION: BS 2573 MPI METHOD: N/A PARTS EXAMINED: Entire body RESULTS: No defect as at the time of inspection. Fit for use TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A
Name and address of equipment owner : Pacific Drilling
Address of premises where test / Examination was held: Pacific Bora
We hereby certify that on 07/08/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection. Fit for use Signature of Inspector: Conducting Examination Name of Inspector: OLATUNJI AKINLADE Conducting: Examination only
Revision No: 01
Doc No: JCI-C-V-01
JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: service@jcinternationalng.com Website: www.jcinternationalng.com
CERTIFICATE OF VISUAL EXAMINATION
STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998
Certificate No. 7509 Identification Number Qty
Date of Examination 07/08/2012
Examiner OLATUNJI AKINLADE TARE WT SWL
Qualifications LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Description of Equipment
Examination
FABRICATED PADEYE
MPR 03
1
A Steel Construction Fabricated Pad Eye / Anchor Point
N/A
2 tonnes
N/A
N/A
06/02/13
LOCATION: MUD PUMP ROOM
SPECIFICATION: BS 2573 MPI METHOD: N/A PARTS EXAMINED: Entire body RESULTS: No defect as at the time of inspection. Fit for use TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A
Name and address of equipment owner : Pacific Drilling
Address of premises where test / Examination was held: Pacific Bora
We hereby certify that on 07/08/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection. Fit for use Signature of Inspector: Conducting Examination Name of Inspector: OLATUNJI AKINLADE Conducting: Examination only
Revision No: 01
Doc No: JCI-C-V-01
JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: service@jcinternationalng.com Website: www.jcinternationalng.com
CERTIFICATE OF VISUAL EXAMINATION
STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998
Certificate No. 7510 Identification Number Qty
Date of Examination 07/08/2012
Examiner OLATUNJI AKINLADE TARE WT SWL
Qualifications LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Description of Equipment
Examination
FABRICATED PADEYE
MPR 04
1
A Steel Construction Fabricated Pad Eye / Anchor Point
N/A
2 tonnes
N/A
N/A
06/02/13
LOCATION: MUD PUMP ROOM
SPECIFICATION: BS 2573 MPI METHOD: N/A PARTS EXAMINED: Entire body RESULTS: No defect as at the time of inspection. Fit for use TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A
Name and address of equipment owner: Pacific Drilling
Address of premises where test / Examination was held: Pacific Bora
We hereby certify that on 07/08/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection. Fit for use Signature of Inspector: Conducting Examination Name of Inspector: OLATUNJI AKINLADE Conducting: Examination only
Revision No: 01
Doc No: JCI-C-V-01
JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: service@jcinternationalng.com Website: www.jcinternationalng.com
CERTIFICATE OF VISUAL EXAMINATION
STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998
Certificate No. 7511 Identification Number Qty
Date of Examination 07/08/2012
Examiner OLATUNJI AKINLADE TARE WT SWL
Qualifications LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Description of Equipment
Examination
FABRICATED PADEYE
MPR 05
1
A Steel Construction Fabricated Pad Eye / Anchor Point
N/A
2 tonnes
N/A
N/A
06/02/13
LOCATION: MUD PUMP ROOM
SPECIFICATION: BS 2573 MPI METHOD: N/A PARTS EXAMINED: Entire body RESULTS: No defect as at the time of inspection. Fit for use TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A
Name and address of equipment owner: Pacific Drilling
Address of premises where test / Examination was held: Pacific Bora
We hereby certify that on 07/08/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection. Fit for use Signature of Inspector: Conducting Examination Name of Inspector: OLATUNJI AKINLADE Conducting: Examination only
Revision No: 01
Doc No: JCI-C-V-01
JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: service@jcinternationalng.com Website: www.jcinternationalng.com
CERTIFICATE OF VISUAL EXAMINATION
STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998
Certificate No. 7512 Identification Number Qty
Date of Examination 07/08/2012
Examiner OLATUNJI AKINLADE TARE WT SWL
Qualifications LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Description of Equipment
Examination
FABRICATED PADEYE
MPR 06
1
A Steel Construction Fabricated Pad Eye / Anchor Point
N/A
2 tonnes
N/A
N/A
06/02/13
LOCATION: MUD PUMP ROOM
SPECIFICATION: BS 2573 MPI METHOD: N/A PARTS EXAMINED: Entire body RESULTS: No defect as at the time of inspection. Fit for use TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A
Name and address of equipment owner : Pacific Drilling
Address of premises where test / Examination was held: Pacific Bora
We hereby certify that on 07/08/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection. Fit for use Signature of Inspector: Conducting Examination Name of Inspector: OLATUNJI AKINLADE Conducting: Examination only
Revision No: 01
Doc No: JCI-C-V-01
JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: service@jcinternationalng.com Website: www.jcinternationalng.com
CERTIFICATE OF VISUAL EXAMINATION
STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998
Certificate No. 7513 Identification Number Qty
Date of Examination 07/08/2012
Examiner OLATUNJI AKINLADE TARE WT SWL
Qualifications LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Description of Equipment
Examination
FABRICATED PADEYE
MPR 07
1
A Steel Construction Fabricated Pad Eye / Anchor Point
N/A
2 tonnes
N/A
N/A
06/02/13
LOCATION: MUD PUMP ROOM
SPECIFICATION: BS 2573 MPI METHOD: N/A PARTS EXAMINED: Entire body RESULTS: No defect as at the time of inspection. Fit for use TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A
Name and address of equipment owner : Pacific Drilling
Address of premises where test / Examination was held: Pacific Bora
We hereby certify that on 07/08/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection. Fit for use Signature of Inspector: Conducting Examination Name of Inspector: OLATUNJI AKINLADE Conducting: Examination only
Revision No: 01
Doc No: JCI-C-V-01
JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: service@jcinternationalng.com Website: www.jcinternationalng.com
CERTIFICATE OF VISUAL EXAMINATION
STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998
Certificate No. 7514 Identification Number Qty
Date of Examination 07/08/2012
Examiner OLATUNJI AKINLADE TARE WT SWL
Qualifications LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Description of Equipment
Examination
FABRICATED PADEYE
MPR 08
1
A Steel Construction Fabricated Pad Eye / Anchor Point
N/A
2 tonnes
N/A
N/A
06/02/13
LOCATION: MUD PUMP ROOM
SPECIFICATION: BS 2573 MPI METHOD: N/A PARTS EXAMINED: Entire body RESULTS: No defect as at the time of inspection. Fit for use TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A
Name and address of equipment owner : Pacific Drilling
Address of premises where test / Examination was held: Pacific Bora
We hereby certify that on 07/08/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection. Fit for use Signature of Inspector: Conducting Examination Name of Inspector: OLATUNJI AKINLADE Conducting: Examination only
Revision No: 01
Doc No: JCI-C-V-01
JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: service@jcinternationalng.com Website: www.jcinternationalng.com
CERTIFICATE OF VISUAL EXAMINATION
STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998
Certificate No. 7515 Identification Number Qty
Date of Examination 07/08/2012
Examiner OLATUNJI AKINLADE TARE WT SWL
Qualifications LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Description of Equipment
Examination
FABRICATED PADEYE
MPR 09
1
A Steel Construction Fabricated Pad Eye / Anchor Point
N/A
2 tonnes
N/A
N/A
06/02/13
LOCATION: MUD PUMP ROOM
SPECIFICATION: BS 2573 MPI METHOD: N/A PARTS EXAMINED: Entire body RESULTS: No defect as at the time of inspection. Fit for use TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A
Name and address of equipment owner : Pacific Drilling
Address of premises where test / Examination was held: Pacific Bora
We hereby certify that on 07/08/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection. Fit for use Signature of Inspector: Conducting Examination Name of Inspector: OLATUNJI AKINLADE Conducting: Examination only
Revision No: 01
Doc No: JCI-C-V-01
JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: service@jcinternationalng.com Website: www.jcinternationalng.com
CERTIFICATE OF VISUAL EXAMINATION
STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998
Certificate No. 7516 Identification Number Qty
Date of Examination 07/08/2012
Examiner OLATUNJI AKINLADE TARE WT SWL
Qualifications LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Description of Equipment
Examination
FABRICATED PADEYE
MPR 10
1
A Steel Construction Fabricated Pad Eye / Anchor Point
N/A
2 tonnes
N/A
N/A
06/02/13
LOCATION: MUD PUMP ROOM
SPECIFICATION: BS 2573 MPI METHOD: N/A PARTS EXAMINED: Entire body RESULTS: No defect as at the time of inspection. Fit for use TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A
Name and address of equipment owner : Pacific Drilling
Address of premises where test / Examination was held: Pacific Bora
We hereby certify that on 07/08/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection. Fit for use Signature of Inspector: Conducting Examination Name of Inspector: OLATUNJI AKINLADE Conducting: Examination only
Revision No: 01
Doc No: JCI-C-V-01
JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: service@jcinternationalng.com Website: www.jcinternationalng.com
CERTIFICATE OF VISUAL EXAMINATION
STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998
Certificate No. 7517 Identification Number Qty
Date of Examination 07/08/2012
Examiner OLATUNJI AKINLADE TARE WT SWL
Qualifications LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Description of Equipment
Examination
FABRICATED PADEYE
MPR 11
1
A Steel Construction Fabricated Pad Eye / Anchor Point
N/A
2 tonnes
N/A
N/A
06/02/13
LOCATION: MUD PUMP ROOM
SPECIFICATION: BS 2573 MPI METHOD: N/A PARTS EXAMINED: Entire body RESULTS: No defect as at the time of inspection. Fit for use TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A
Name and address of equipment owner : Pacific Drilling
Address of premises where test / Examination was held: Pacific Bora
We hereby certify that on 07/08/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection. Fit for use Signature of Inspector: Conducting Examination Name of Inspector: OLATUNJI AKINLADE Conducting: Examination only
Revision No: 01
Doc No: JCI-C-V-01
JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: service@jcinternationalng.com Website: www.jcinternationalng.com
CERTIFICATE OF VISUAL EXAMINATION
STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998
Certificate No. 7518 Identification Number Qty
Date of Examination 07/08/2012
Examiner OLATUNJI AKINLADE TARE WT SWL
Qualifications LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Description of Equipment
Examination
FABRICATED PADEYE
MPR 12
1
A Steel Construction Fabricated Pad Eye / Anchor Point
N/A
2 tonnes
N/A
N/A
06/02/13
LOCATION: MUD PUMP ROOM
SPECIFICATION: BS 2573 MPI METHOD: N/A PARTS EXAMINED: Entire body RESULTS: No defect as at the time of inspection. Fit for use TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A
Name and address of equipment owner : Pacific Drilling
Address of premises where test / Examination was held: Pacific Bora
We hereby certify that on 07/08/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection. Fit for use Signature of Inspector: Conducting Examination Name of Inspector: OLATUNJI AKINLADE Conducting: Examination only
Revision No: 01
Doc No: JCI-C-V-01
JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: service@jcinternationalng.com Website: www.jcinternationalng.com
CERTIFICATE OF VISUAL EXAMINATION
STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998
Certificate No. 7519 Identification Number Qty
Date of Examination 07/08/2012
Examiner OLATUNJI AKINLADE TARE WT SWL
Qualifications LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Description of Equipment
Examination
FABRICATED PADEYE
MPR 13
1
A Steel Construction Fabricated Pad Eye / Anchor Point
N/A
2 tonnes
N/A
N/A
06/02/13
LOCATION: MUD PUMP ROOM
SPECIFICATION: BS 2573 MPI METHOD: N/A PARTS EXAMINED: Entire body RESULTS: No defect as at the time of inspection. Fit for use TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A
Name and address of equipment owner : Pacific Drilling
Address of premises where test / Examination was held: Pacific Bora
We hereby certify that on 07/08/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection. Fit for use Signature of Inspector: Conducting Examination Name of Inspector: OLATUNJI AKINLADE Conducting: Examination only
Revision No: 01
Doc No: JCI-C-V-01
JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: service@jcinternationalng.com Website: www.jcinternationalng.com
CERTIFICATE OF VISUAL EXAMINATION
STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998
Certificate No. 7520 Identification Number Qty
Date of Examination 08/08/2012
Examiner OLATUNJI AKINLADE TARE WT SWL
Qualifications LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Description of Equipment
Examination
FABRICATED PADEYE
SH 1
1
A Steel Construction Fabricated Pad Eye / Anchor Point
N/A
3 tonnes
N/A
N/A
07/02/13
LOCATION: SHAKER ROOM
SPECIFICATION: BS 2573 MPI METHOD: N/A PARTS EXAMINED: Entire body RESULTS: No defect as at the time of inspection. Fit for use TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A
Name and address of equipment owner : Pacific Drilling
Address of premises where test / Examination was held: Pacific Bora
We hereby certify that on 08/08/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection. Fit for use Signature of Inspector: Conducting Examination Name of Inspector: OLATUNJI AKINLADE Conducting: Examination only
Revision No: 01
Doc No: JCI-C-V-01
JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: service@jcinternationalng.com Website: www.jcinternationalng.com
CERTIFICATE OF VISUAL EXAMINATION
STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998
Certificate No. 7521 Identification Number Qty
Date of Examination 08/08/2012
Examiner OLATUNJI AKINLADE TARE WT SWL
Qualifications LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Description of Equipment
Examination
FABRICATED PADEYE
SH 2
1
A Steel Construction Fabricated Pad Eye / Anchor Point
N/A
3 tonnes
N/A
N/A
07/02/13
LOCATION: SHAKER ROOM
SPECIFICATION: BS 2573 MPI METHOD: N/A PARTS EXAMINED: Entire body RESULTS: No defect as at the time of inspection. Fit for use TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A
Name and address of equipment owner : Pacific Drilling
Address of premises where test / Examination was held: Pacific Bora
We hereby certify that on 08/08/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection. Fit for use Signature of Inspector: Conducting Examination Name of Inspector: OLATUNJI AKINLADE Conducting: Examination only
Revision No: 01
Doc No: JCI-C-V-01
JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: service@jcinternationalng.com Website: www.jcinternationalng.com
CERTIFICATE OF VISUAL EXAMINATION
STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998
Certificate No. 7522 Identification Number Qty
Date of Examination 08/08/2012
Examiner OLATUNJI AKINLADE TARE WT SWL
Qualifications LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Description of Equipment
Examination
FABRICATED PADEYE
XPE 3
1
A Steel Construction Fabricated Pad Eye / Anchor Point
N/A
10 tonnes
N/A
N/A
07/02/13
LOCATION: ABOVE BRANDT UNIT
SPECIFICATION: BS 2573 MPI METHOD: N/A PARTS EXAMINED: Entire body RESULTS: No defect as at the time of inspection. Fit for use TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A
Name and address of equipment owner : Pacific Drilling
Address of premises where test / Examination was held: Pacific Bora
We hereby certify that on 08/08/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection. Fit for use Signature of Inspector: Conducting Examination Name of Inspector: OLATUNJI AKINLADE Conducting: Examination only
Revision No: 01
Doc No: JCI-C-V-01
JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: service@jcinternationalng.com Website: www.jcinternationalng.com
CERTIFICATE OF VISUAL EXAMINATION
STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998
Certificate No. 7523 Identification Number Qty
Date of Examination 08/08/2012
Examiner OLATUNJI AKINLADE TARE WT SWL
Qualifications LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Description of Equipment
Examination
FABRICATED PADEYE
XPE 29
1
A Steel Construction Fabricated Pad Eye / Anchor Point
N/A
1.5 tonnes
N/A
N/A
07/02/13
LOCATION: TOTE TANK PLATFORM
SPECIFICATION: BS 2573 MPI METHOD: N/A PARTS EXAMINED: Entire body RESULTS: No defect as at the time of inspection. Fit for use TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A
Name and address of equipment owner : Pacific Drilling
Address of premises where test / Examination was held: Pacific Bora
We hereby certify that on 08/08/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection. Fit for use Signature of Inspector: Conducting Examination Name of Inspector: OLATUNJI AKINLADE Conducting: Examination only
Revision No: 01
Doc No: JCI-C-V-01
JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: service@jcinternationalng.com Website: www.jcinternationalng.com
CERTIFICATE OF VISUAL EXAMINATION
STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998
Certificate No. 7524 Identification Number Qty
Date of Examination 08/08/2012
Examiner OLATUNJI AKINLADE TARE WT SWL
Qualifications LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Description of Equipment
Examination
FABRICATED PADEYE
XPE 30
1
A Steel Construction Fabricated Pad Eye / Anchor Point
N/A
1.5 tonnes
N/A
N/A
07/02/13
LOCATION: TOTE TANK PLATFORM
SPECIFICATION: BS 2573 MPI METHOD: N/A PARTS EXAMINED: Entire body RESULTS: No defect as at the time of inspection. Fit for use TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A
Name and address of equipment owner : Pacific Drilling
Address of premises where test / Examination was held: Pacific Bora
We hereby certify that on 08/08/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection. Fit for use Signature of Inspector: Conducting Examination Name of Inspector: OLATUNJI AKINLADE Conducting: Examination only
Revision No: 01
Doc No: JCI-C-V-01
JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: service@jcinternationalng.com Website: www.jcinternationalng.com
CERTIFICATE OF VISUAL EXAMINATION
STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998
Certificate No. 7525 Identification Number Qty
Date of Examination 08/08/2012
Examiner OLATUNJI AKINLADE TARE WT SWL
Qualifications LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Description of Equipment
Examination
FABRICATED PADEYE
XPE 31
1
A Steel Construction Fabricated Pad Eye / Anchor Point
N/A
1.5 tonnes
N/A
N/A
07/02/13
LOCATION: TOTE TANK PLATFORM
SPECIFICATION: BS 2573 MPI METHOD: N/A PARTS EXAMINED: Entire body RESULTS: No defect as at the time of inspection. Fit for use TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A
Name and address of equipment owner : Pacific Drilling
Address of premises where test / Examination was held: Pacific Bora
We hereby certify that on 08/08/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection. Fit for use Signature of Inspector: Conducting Examination Name of Inspector: OLATUNJI AKINLADE Conducting: Examination only
Revision No: 01
Doc No: JCI-C-V-01
JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: service@jcinternationalng.com Website: www.jcinternationalng.com
CERTIFICATE OF VISUAL EXAMINATION
STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998
Certificate No. 7526 Identification Number Qty
Date of Examination 08/08/2012
Examiner OLATUNJI AKINLADE TARE WT SWL
Qualifications LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Description of Equipment
Examination
FABRICATED PADEYE
XPE 32
1
A Steel Construction Fabricated Pad Eye / Anchor Point
N/A
1.5 tonnes
N/A
N/A
07/02/13
LOCATION: TOTE TANK PLATFORM
SPECIFICATION: BS 2573 MPI METHOD: N/A PARTS EXAMINED: Entire body RESULTS: No defect as at the time of inspection. Fit for use TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A
Name and address of equipment owner: Pacific Drilling
Address of premises where test / Examination was held: Pacific Bora
We hereby certify that on 08/08/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection. Fit for use Signature of Inspector: Conducting Examination Name of Inspector: OLATUNJI AKINLADE Conducting: Examination only
Revision No: 01
Doc No: JCI-C-V-01
JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: service@jcinternationalng.com Website: www.jcinternationalng.com
CERTIFICATE OF VISUAL EXAMINATION
STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998
Certificate No. 7527 Identification Number Qty
Date of Examination 08/08/2012
Examiner OLATUNJI AKINLADE TARE WT SWL
Qualifications LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Description of Equipment
Examination
FABRICATED PADEYE
XPE 33
1
A Steel Construction Fabricated Pad Eye / Anchor Point
N/A
1 tonne
N/A
N/A
07/02/13
LOCATION: TOTE TANK PLATFORM
SPECIFICATION: BS 2573 MPI METHOD: N/A PARTS EXAMINED: Entire body RESULTS: No defect as at the time of inspection. Fit for use TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A
Name and address of equipment owner : Pacific Drilling
Address of premises where test / Examination was held: Pacific Bora
We hereby certify that on 08/08/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection. Fit for use Signature of Inspector: Conducting Examination Name of Inspector: OLATUNJI AKINLADE Conducting: Examination only
Revision No: 01
Doc No: JCI-C-V-01
JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: service@jcinternationalng.com Website: www.jcinternationalng.com
CERTIFICATE OF VISUAL EXAMINATION
STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998
Certificate No. 7528 Identification Number Qty
Date of Examination 08/08/2012
Examiner OLATUNJI AKINLADE TARE WT SWL
Qualifications LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Description of Equipment
Examination
FABRICATED PADEYE
XPE 34
1
A Steel Construction Fabricated Pad Eye / Anchor Point
N/A
1 tonne
N/A
N/A
07/02/13
LOCATION: TOTE TANK PLATFORM
SPECIFICATION: BS 2573 MPI METHOD: N/A PARTS EXAMINED: Entire body RESULTS: No defect as at the time of inspection. Fit for use TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A
Name and address of equipment owner : Pacific Drilling
Address of premises where test / Examination was held: Pacific Bora
We hereby certify that on 08/08/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection. Fit for use Signature of Inspector: Conducting Examination Name of Inspector: OLATUNJI AKINLADE Conducting: Examination only
Revision No: 01
Doc No: JCI-C-V-01
JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: service@jcinternationalng.com Website: www.jcinternationalng.com
CERTIFICATE OF VISUAL EXAMINATION
STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998
Certificate No. 7529 Identification Number Qty
Date of Examination 08/08/2012
Examiner OLATUNJI AKINLADE TARE WT SWL
Qualifications LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Description of Equipment
Examination
FABRICATED PADEYE
XPE 35
1
A Steel Construction Fabricated Pad Eye / Anchor Point
N/A
1 tonne
N/A
N/A
07/02/13
LOCATION: TOTE TANK PLATFORM
SPECIFICATION: BS 2573 MPI METHOD: N/A PARTS EXAMINED: Entire body RESULTS: No defect as at the time of inspection. Fit for use TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A
Name and address of equipment owner : Pacific Drilling
Address of premises where test / Examination was held: Pacific Bora
We hereby certify that on 08/08/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection. Fit for use Signature of Inspector: Conducting Examination Name of Inspector: OLATUNJI AKINLADE Conducting: Examination only
Revision No: 01
Doc No: JCI-C-V-01
JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: service@jcinternationalng.com Website: www.jcinternationalng.com
CERTIFICATE OF VISUAL EXAMINATION
STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998
Certificate No. 7530 Identification Number Qty
Date of Examination 08/08/2012
Examiner OLATUNJI AKINLADE TARE WT SWL
Qualifications LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Description of Equipment
Examination
FABRICATED PADEYE
XPE 36
1
A Steel Construction Fabricated Pad Eye / Anchor Point
N/A
1 tonne
N/A
N/A
07/02/13
LOCATION: TOTE TANK PLATFORM
SPECIFICATION: BS 2573 MPI METHOD: N/A PARTS EXAMINED: Entire body RESULTS: No defect as at the time of inspection. Fit for use TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A
Name and address of equipment owner : Pacific Drilling
Address of premises where test / Examination was held: Pacific Bora
We hereby certify that on 08/08/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection. Fit for use Signature of Inspector: Conducting Examination Name of Inspector: OLATUNJI AKINLADE Conducting: Examination only
Revision No: 01
Doc No: JCI-C-V-01
JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: service@jcinternationalng.com Website: www.jcinternationalng.com
CERTIFICATE OF VISUAL EXAMINATION
STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998
Certificate No. 7521 Identification Number Qty
Date of Examination 08/08/2012
Examiner OLATUNJI AKINLADE TARE WT SWL
Qualifications LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Description of Equipment
Examination
FABRICATED PADEYE
BSR-001
1
A Steel Construction Fabricated Pad Eye / Anchor Point
N/A
1 tonne
N/A
N/A
07/02/13
LOCATION: BULK TANK STORAGE ROOM
SPECIFICATION: BS 2573 MPI METHOD: N/A PARTS EXAMINED: Entire body RESULTS: No defect as at the time of inspection. Fit for use TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A
Name and address of equipment owner : Pacific Drilling
Address of premises where test / Examination was held: Pacific Bora
We hereby certify that on 08/08/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection. Fit for use Signature of Inspector: Conducting Examination Name of Inspector: OLATUNJI AKINLADE Conducting: Examination only
Revision No: 01
Doc No: JCI-C-V-01
JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: service@jcinternationalng.com Website: www.jcinternationalng.com
CERTIFICATE OF VISUAL EXAMINATION
STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998
Certificate No. 7522 Identification Number Qty
Date of Examination 08/08/2012
Examiner OLATUNJI AKINLADE TARE WT SWL
Qualifications LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Description of Equipment
Examination
FABRICATED PADEYE
BSR-002
1
A Steel Construction Fabricated Pad Eye / Anchor Point
N/A
1 tonne
N/A
N/A
07/02/13
LOCATION: BULK TANK STORAGE ROOM
SPECIFICATION: BS 2573 MPI METHOD: N/A PARTS EXAMINED: Entire body RESULTS: No defect as at the time of inspection. Fit for use TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A
Name and address of equipment owner : Pacific Drilling
Address of premises where test / Examination was held: Pacific Bora
We hereby certify that on 08/08/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection. Fit for use Signature of Inspector: Conducting Examination Name of Inspector: OLATUNJI AKINLADE Conducting: Examination only
Revision No: 01
Doc No: JCI-C-V-01
JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: service@jcinternationalng.com Website: www.jcinternationalng.com
CERTIFICATE OF VISUAL EXAMINATION
STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998
Certificate No. 7523 Identification Number Qty
Date of Examination 08/08/2012
Examiner OLATUNJI AKINLADE TARE WT SWL
Qualifications LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Description of Equipment
Examination
FABRICATED PADEYE
BSR-003
1
A Steel Construction Fabricated Pad Eye / Anchor Point
N/A
1 tonne
N/A
N/A
07/02/13
LOCATION: BULK TANK STORAGE ROOM
SPECIFICATION: BS 2573 MPI METHOD: N/A PARTS EXAMINED: Entire body RESULTS: No defect as at the time of inspection. Fit for use TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A
Name and address of equipment owner : Pacific Drilling
Address of premises where test / Examination was held: Pacific Bora
We hereby certify that on 08/08/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection. Fit for use Signature of Inspector: Conducting Examination Name of Inspector: OLATUNJI AKINLADE Conducting: Examination only
Revision No: 01
Doc No: JCI-C-V-01
JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: service@jcinternationalng.com Website: www.jcinternationalng.com
CERTIFICATE OF VISUAL EXAMINATION
STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998
Certificate No. 7524 Identification Number Qty
Date of Examination 08/08/2012
Examiner OLATUNJI AKINLADE TARE WT SWL
Qualifications LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Description of Equipment
Examination
FABRICATED PADEYE
BSR-004
1
A Steel Construction Fabricated Pad Eye / Anchor Point
N/A
1 tonne
N/A
N/A
07/02/13
LOCATION: BULK TANK STORAGE ROOM
SPECIFICATION: BS 2573 MPI METHOD: N/A PARTS EXAMINED: Entire body RESULTS: No defect as at the time of inspection. Fit for use TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A
Name and address of equipment owner : Pacific Drilling
Address of premises where test / Examination was held: Pacific Bora
We hereby certify that on 08/08/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection. Fit for use Signature of Inspector: Conducting Examination Name of Inspector: OLATUNJI AKINLADE Conducting: Examination only
Revision No: 01
Doc No: JCI-C-V-01
JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: service@jcinternationalng.com Website: www.jcinternationalng.com
CERTIFICATE OF VISUAL EXAMINATION
STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998
Certificate No. 7525 Identification Number Qty
Date of Examination 08/08/2012
Examiner OLATUNJI AKINLADE TARE WT SWL
Qualifications LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Description of Equipment
Examination
FABRICATED PADEYE
BSR-005
1
A Steel Construction Fabricated Pad Eye / Anchor Point
N/A
1 tonne
N/A
N/A
07/02/13
LOCATION: BULK TANK STORAGE ROOM
SPECIFICATION: BS 2573 MPI METHOD: N/A PARTS EXAMINED: Entire body RESULTS: No defect as at the time of inspection. Fit for use TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A
Name and address of equipment owner : Pacific Drilling
Address of premises where test / Examination was held: Pacific Bora
We hereby certify that on 08/08/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection. Fit for use Signature of Inspector: Conducting Examination Name of Inspector: OLATUNJI AKINLADE Conducting: Examination only
Revision No: 01
Doc No: JCI-C-V-01
JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: service@jcinternationalng.com Website: www.jcinternationalng.com
CERTIFICATE OF VISUAL EXAMINATION
STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998
Certificate No. 7526 Identification Number Qty
Date of Examination 08/08/2012
Examiner OLATUNJI AKINLADE TARE WT SWL
Qualifications LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Description of Equipment
Examination
FABRICATED PADEYE
BSR-006
1
A Steel Construction Fabricated Pad Eye / Anchor Point
N/A
1 tonne
N/A
N/A
07/02/13
LOCATION: BULK TANK STORAGE ROOM
SPECIFICATION: BS 2573 MPI METHOD: N/A PARTS EXAMINED: Entire body RESULTS: No defect as at the time of inspection. Fit for use TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A
Name and address of equipment owner : Pacific Drilling
Address of premises where test / Examination was held: Pacific Bora
We hereby certify that on 08/08/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection. Fit for use Signature of Inspector: Conducting Examination Name of Inspector: OLATUNJI AKINLADE Conducting: Examination only
Revision No: 01
Doc No: JCI-C-V-01
JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: service@jcinternationalng.com Website: www.jcinternationalng.com
CERTIFICATE OF VISUAL EXAMINATION
STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998
Certificate No. 7527 Identification Number Qty
Date of Examination 08/08/2012
Examiner OLATUNJI AKINLADE TARE WT SWL
Qualifications LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Description of Equipment
Examination
FABRICATED PADEYE
BSR-007
1
A Steel Construction Fabricated Pad Eye / Anchor Point
N/A
2 tonnes
N/A
N/A
07/02/13
LOCATION: BULK TANK STORAGE ROOM
SPECIFICATION: BS 2573 MPI METHOD: N/A PARTS EXAMINED: Entire body RESULTS: No defect as at the time of inspection. Fit for use TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A
Name and address of equipment owner: Pacific Drilling
Address of premises where test / Examination was held: Pacific Bora
We hereby certify that on 08/08/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection. Fit for use Signature of Inspector: Conducting Examination Name of Inspector: OLATUNJI AKINLADE Conducting: Examination only
Revision No: 01
Doc No: JCI-C-V-01
JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: service@jcinternationalng.com Website: www.jcinternationalng.com
CERTIFICATE OF VISUAL EXAMINATION
STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998
Certificate No. 7528 Identification Number Qty
Date of Examination 08/08/2012
Examiner OLATUNJI AKINLADE TARE WT SWL
Qualifications LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Description of Equipment
Examination
FABRICATED PADEYE
BSR-008
1
A Steel Construction Fabricated Pad Eye / Anchor Point
N/A
2 tonnes
N/A
N/A
07/02/13
LOCATION: BULK TANK STORAGE ROOM
SPECIFICATION: BS 2573 MPI METHOD: N/A PARTS EXAMINED: Entire body RESULTS: No defect as at the time of inspection. Fit for use TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A
Name and address of equipment owner : Pacific Drilling
Address of premises where test / Examination was held: Pacific Bora
We hereby certify that on 08/08/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection. Fit for use Signature of Inspector: Conducting Examination Name of Inspector: OLATUNJI AKINLADE Conducting: Examination only
Revision No: 01
Doc No: JCI-C-V-01
JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: service@jcinternationalng.com Website: www.jcinternationalng.com
CERTIFICATE OF VISUAL EXAMINATION
STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998
Certificate No. 7529 Identification Number Qty
Date of Examination 08/08/2012
Examiner OLATUNJI AKINLADE TARE WT SWL
Qualifications LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Description of Equipment
Examination
FABRICATED PADEYE
BSR-009
1
A Steel Construction Fabricated Pad Eye / Anchor Point
N/A
2 tonnes
N/A
N/A
07/02/13
LOCATION: BULK TANK STORAGE ROOM
SPECIFICATION: BS 2573 MPI METHOD: N/A PARTS EXAMINED: Entire body RESULTS: No defect as at the time of inspection. Fit for use TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A
Name and address of equipment owner : Pacific Drilling
Address of premises where test / Examination was held: Pacific Bora
We hereby certify that on 08/08/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection. Fit for use Signature of Inspector: Conducting Examination Name of Inspector: OLATUNJI AKINLADE Conducting: Examination only
Revision No: 01
Doc No: JCI-C-V-01
JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: service@jcinternationalng.com Website: www.jcinternationalng.com
CERTIFICATE OF VISUAL EXAMINATION
STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998
Certificate No. 7530 Identification Number Qty
Date of Examination 08/08/2012
Examiner OLATUNJI AKINLADE TARE WT SWL
Qualifications LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Description of Equipment
Examination
FABRICATED PADEYE
BSR-010
1
A Steel Construction Fabricated Pad Eye / Anchor Point
N/A
2 tonnes
N/A
N/A
07/02/13
LOCATION: BULK TANK STORAGE ROOM
SPECIFICATION: BS 2573 MPI METHOD: N/A PARTS EXAMINED: Entire body RESULTS: No defect as at the time of inspection. Fit for use TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A
Name and address of equipment owner : Pacific Drilling
Address of premises where test / Examination was held: Pacific Bora
We hereby certify that on 08/08/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection. Fit for use Signature of Inspector: Conducting Examination Name of Inspector: OLATUNJI AKINLADE Conducting: Examination only
Revision No: 01
Doc No: JCI-C-V-01
JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: service@jcinternationalng.com Website: www.jcinternationalng.com
CERTIFICATE OF VISUAL EXAMINATION
STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998
Certificate No. 7531 Identification Number Qty
Date of Examination 08/08/2012
Examiner OLATUNJI AKINLADE TARE WT SWL
Qualifications LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Description of Equipment
Examination
FABRICATED PADEYE
BSR-011
1
A Steel Construction Fabricated Pad Eye / Anchor Point
N/A
1 tonne
N/A
N/A
07/02/13
LOCATION: BULK TANK STORAGE ROOM
SPECIFICATION: BS 2573 MPI METHOD: N/A PARTS EXAMINED: Entire body RESULTS: No defect as at the time of inspection. Fit for use TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A
Name and address of equipment owner : Pacific Drilling
Address of premises where test / Examination was held: Pacific Bora
We hereby certify that on 08/08/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection. Fit for use Signature of Inspector: Conducting Examination Name of Inspector: OLATUNJI AKINLADE Conducting: Examination only
Revision No: 01
Doc No: JCI-C-V-01
JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: service@jcinternationalng.com Website: www.jcinternationalng.com
CERTIFICATE OF VISUAL EXAMINATION
STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998
Certificate No. 7532 Identification Number Qty
Date of Examination 08/08/2012
Examiner OLATUNJI AKINLADE TARE WT SWL
Qualifications LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Description of Equipment
Examination
FABRICATED PADEYE
BSR-012
1
A Steel Construction Fabricated Pad Eye / Anchor Point
N/A
2 tonnes
N/A
N/A
07/02/13
LOCATION: BULK TANK STORAGE ROOM
SPECIFICATION: BS 2573 MPI METHOD: N/A PARTS EXAMINED: Entire body RESULTS: No defect as at the time of inspection. Fit for use TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A
Name and address of equipment owner : Pacific Drilling
Address of premises where test / Examination was held: Pacific Bora
We hereby certify that on 08/08/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection. Fit for use Signature of Inspector: Conducting Examination Name of Inspector: OLATUNJI AKINLADE Conducting: Examination only
Revision No: 01
Doc No: JCI-C-V-01
JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: service@jcinternationalng.com Website: www.jcinternationalng.com
CERTIFICATE OF VISUAL EXAMINATION
STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998
Certificate No. 7533 Identification Number Qty
Date of Examination 08/08/2012
Examiner OLATUNJI AKINLADE TARE WT SWL
Qualifications LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Description of Equipment
Examination
FABRICATED PADEYE
BSR-013
1
A Steel Construction Fabricated Pad Eye / Anchor Point
N/A
2 tonnes
N/A
N/A
07/02/13
LOCATION: BULK TANK STORAGE ROOM
SPECIFICATION: BS 2573 MPI METHOD: N/A PARTS EXAMINED: Entire body RESULTS: No defect as at the time of inspection. Fit for use TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A
Name and address of equipment owner : Pacific Drilling
Address of premises where test / Examination was held: Pacific Bora
We hereby certify that on 08/08/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection. Fit for use Signature of Inspector: Conducting Examination Name of Inspector: OLATUNJI AKINLADE Conducting: Examination only
Revision No: 01
Doc No: JCI-C-V-01
JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: service@jcinternationalng.com Website: www.jcinternationalng.com
CERTIFICATE OF VISUAL EXAMINATION
STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998
Certificate No. 7534 Identification Number Qty
Date of Examination 08/08/2012
Examiner OLATUNJI AKINLADE TARE WT SWL
Qualifications LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Description of Equipment
Examination
FABRICATED PADEYE
BSR-014
1
A Steel Construction Fabricated Pad Eye / Anchor Point
N/A
1 tonne
N/A
N/A
07/02/13
LOCATION: BULK TANK STORAGE ROOM
SPECIFICATION: BS 2573 MPI METHOD: N/A PARTS EXAMINED: Entire body RESULTS: No defect as at the time of inspection. Fit for use TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A
Name and address of equipment owner : Pacific Drilling
Address of premises where test / Examination was held: Pacific Bora
We hereby certify that on 08/08/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection. Fit for use Signature of Inspector: Conducting Examination Name of Inspector: OLATUNJI AKINLADE Conducting: Examination only
Revision No: 01
Doc No: JCI-C-V-01
JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: service@jcinternationalng.com Website: www.jcinternationalng.com
CERTIFICATE OF VISUAL EXAMINATION
STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998
Certificate No. 7535 Identification Number Qty
Date of Examination 08/08/2012
Examiner OLATUNJI AKINLADE TARE WT SWL
Qualifications LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Description of Equipment
Examination
FABRICATED PADEYE
BSR-015
1
A Steel Construction Fabricated Pad Eye / Anchor Point
N/A
2 tonnes
N/A
N/A
07/02/13
LOCATION: BULK TANK STORAGE ROOM
SPECIFICATION: BS 2573 MPI METHOD: N/A PARTS EXAMINED: Entire body RESULTS: No defect as at the time of inspection. Fit for use TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A
Name and address of equipment owner : Pacific Drilling
Address of premises where test / Examination was held: Pacific Bora
We hereby certify that on 08/08/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection. Fit for use Signature of Inspector: Conducting Examination Name of Inspector: OLATUNJI AKINLADE Conducting: Examination only
Revision No: 01
Doc No: JCI-C-V-01
JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: service@jcinternationalng.com Website: www.jcinternationalng.com
CERTIFICATE OF VISUAL EXAMINATION
STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998
Certificate No. 7536 Identification Number Qty
Date of Examination 08/08/2012
Examiner OLATUNJI AKINLADE TARE WT SWL
Qualifications LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Description of Equipment
Examination
FABRICATED PADEYE
BPR-001
1
A Steel Construction Fabricated Pad Eye / Anchor Point
N/A
3 tonnes
N/A
N/A
07/02/13
LOCATION: BALLAST PUMP ROOM
SPECIFICATION: BS 2573 MPI METHOD: N/A PARTS EXAMINED: Entire body RESULTS: No defect as at the time of inspection. Fit for use TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A
Name and address of equipment owner : Pacific Drilling
Address of premises where test / Examination was held: Pacific Bora
We hereby certify that on 08/08/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection. Fit for use Signature of Inspector: Conducting Examination Name of Inspector: OLATUNJI AKINLADE Conducting: Examination only
Revision No: 01
Doc No: JCI-C-V-01
JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: service@jcinternationalng.com Website: www.jcinternationalng.com
CERTIFICATE OF VISUAL EXAMINATION
STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998
Certificate No. 7537 Identification Number Qty
Date of Examination 08/08/2012
Examiner OLATUNJI AKINLADE TARE WT SWL
Qualifications LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Description of Equipment
Examination
FABRICATED PADEYE
BPR-002
1
A Steel Construction Fabricated Pad Eye / Anchor Point
N/A
2 tonnes
N/A
N/A
07/02/13
LOCATION: BALLAST PUMP ROOM
SPECIFICATION: BS 2573 MPI METHOD: N/A PARTS EXAMINED: Entire body RESULTS: No defect as at the time of inspection. Fit for use TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A
Name and address of equipment owner : Pacific Drilling
Address of premises where test / Examination was held: Pacific Bora
We hereby certify that on 08/08/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection. Fit for use Signature of Inspector: Conducting Examination Name of Inspector: OLATUNJI AKINLADE Conducting: Examination only
Revision No: 01
Doc No: JCI-C-V-01
JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: service@jcinternationalng.com Website: www.jcinternationalng.com
CERTIFICATE OF VISUAL EXAMINATION
STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998
Certificate No. 7538 Identification Number Qty
Date of Examination 08/08/2012
Examiner OLATUNJI AKINLADE TARE WT SWL
Qualifications LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Description of Equipment
Examination
FABRICATED PADEYE
BPR-003
1
A Steel Construction Fabricated Pad Eye / Anchor Point
N/A
2 tonnes
N/A
N/A
07/02/13
LOCATION: BALLAST PUMP ROOM
SPECIFICATION: BS 2573 MPI METHOD: N/A PARTS EXAMINED: Entire body RESULTS: No defect as at the time of inspection. Fit for use TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A
Name and address of equipment owner: Pacific Drilling
Address of premises where test / Examination was held: Pacific Bora
We hereby certify that on 08/08/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection. Fit for use Signature of Inspector: Conducting Examination Name of Inspector: OLATUNJI AKINLADE Conducting: Examination only
Revision No: 01
Doc No: JCI-C-V-01
JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: service@jcinternationalng.com Website: www.jcinternationalng.com
CERTIFICATE OF VISUAL EXAMINATION
STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998
Certificate No. 7539 Identification Number Qty
Date of Examination 08/08/2012
Examiner OLATUNJI AKINLADE TARE WT SWL
Qualifications LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Description of Equipment
Examination
FABRICATED PADEYE
BPEF-01
1
A Steel Construction Fabricated Pad Eye / Anchor Point
N/A
2 tonnes
N/A
N/A
07/02/13
LOCATION: BALLAST PUMP EXHAUST FAN
SPECIFICATION: BS 2573 MPI METHOD: N/A PARTS EXAMINED: Entire body RESULTS: No defect as at the time of inspection. Fit for use TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A
Name and address of equipment owner : Pacific Drilling
Address of premises where test / Examination was held: Pacific Bora
We hereby certify that on 08/08/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection. Fit for use Signature of Inspector: Conducting Examination Name of Inspector: OLATUNJI AKINLADE Conducting: Examination only
Revision No: 01
Doc No: JCI-C-V-01
JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: service@jcinternationalng.com Website: www.jcinternationalng.com
CERTIFICATE OF VISUAL EXAMINATION
STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998
Certificate No. 7540 Identification Number Qty
Date of Examination 08/08/2012
Examiner OLATUNJI AKINLADE TARE WT SWL
Qualifications LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Description of Equipment
Examination
FABRICATED PADEYE
BPEF-02
1
A Steel Construction Fabricated Pad Eye / Anchor Point
N/A
2 tonnes
N/A
N/A
07/02/13
LOCATION: BALLAST PUMP EXHAUST FAN
SPECIFICATION: BS 2573 MPI METHOD: N/A PARTS EXAMINED: Entire body RESULTS: No defect as at the time of inspection. Fit for use TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A
Name and address of equipment owner : Pacific Drilling
Address of premises where test / Examination was held: Pacific Bora
We hereby certify that on 08/08/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection. Fit for use Signature of Inspector: Conducting Examination Name of Inspector: OLATUNJI AKINLADE Conducting: Examination only
Revision No: 01
Doc No: JCI-C-V-01
JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: service@jcinternationalng.com Website: www.jcinternationalng.com
CERTIFICATE OF VISUAL EXAMINATION
STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998
Certificate No. 7541 Identification Number Qty
Date of Examination 08/08/2012
Examiner OLATUNJI AKINLADE TARE WT SWL
Qualifications LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Description of Equipment
Examination
FABRICATED PADEYE
BPEF-03
1
A Steel Construction Fabricated Pad Eye / Anchor Point
N/A
2 tonnes
N/A
N/A
07/02/13
LOCATION: BALLAST PUMP EXHAUST FAN
SPECIFICATION: BS 2573 MPI METHOD: N/A PARTS EXAMINED: Entire body RESULTS: No defect as at the time of inspection. Fit for use TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A
Name and address of equipment owner : Pacific Drilling
Address of premises where test / Examination was held: Pacific Bora
We hereby certify that on 08/08/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection. Fit for use Signature of Inspector: Conducting Examination Name of Inspector: OLATUNJI AKINLADE Conducting: Examination only
Revision No: 01
Doc No: JCI-C-V-01
JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: service@jcinternationalng.com Website: www.jcinternationalng.com
CERTIFICATE OF VISUAL EXAMINATION
STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998
Certificate No. 7542 Identification Number Qty
Date of Examination 08/08/2012
Examiner OLATUNJI AKINLADE TARE WT SWL
Qualifications LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Description of Equipment
Examination
FABRICATED PADEYE
BPEF-04
1
A Steel Construction Fabricated Pad Eye / Anchor Point
N/A
2 tonnes
N/A
N/A
07/02/13
LOCATION: BALLAST PUMP EXHAUST FAN
SPECIFICATION: BS 2573 MPI METHOD: N/A PARTS EXAMINED: Entire body RESULTS: No defect as at the time of inspection. Fit for use TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A
Name and address of equipment owner : Pacific Drilling
Address of premises where test / Examination was held: Pacific Bora
We hereby certify that on 08/08/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection. Fit for use Signature of Inspector: Conducting Examination Name of Inspector: OLATUNJI AKINLADE Conducting: Examination only
Revision No: 01
Doc No: JCI-C-V-01
JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: service@jcinternationalng.com Website: www.jcinternationalng.com
CERTIFICATE OF VISUAL EXAMINATION
STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998
Certificate No. 7543 Identification Number Qty
Date of Examination 08/08/2012
Examiner OLATUNJI AKINLADE TARE WT SWL
Qualifications LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Description of Equipment
Examination
FABRICATED PADEYE
BPEF-05
1
A Steel Construction Fabricated Pad Eye / Anchor Point
N/A
2 tonnes
N/A
N/A
07/02/13
LOCATION: BALLAST PUMP EXHAUST FAN
SPECIFICATION: BS 2573 MPI METHOD: N/A PARTS EXAMINED: Entire body RESULTS: No defect as at the time of inspection. Fit for use TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A
Name and address of equipment owner : Pacific Drilling
Address of premises where test / Examination was held: Pacific Bora
We hereby certify that on 08/08/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection. Fit for use Signature of Inspector: Conducting Examination Name of Inspector: OLATUNJI AKINLADE Conducting: Examination only
Revision No: 01
Doc No: JCI-C-V-01
JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: service@jcinternationalng.com Website: www.jcinternationalng.com
CERTIFICATE OF VISUAL EXAMINATION
STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998
Certificate No. 7544 Identification Number Qty
Date of Examination 08/08/2012
Examiner OLATUNJI AKINLADE TARE WT SWL
Qualifications LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Description of Equipment
Examination
FABRICATED PADEYE
BPEF-06
1
A Steel Construction Fabricated Pad Eye / Anchor Point
N/A
2 tonnes
N/A
N/A
07/02/13
LOCATION: BALLAST PUMP EXHAUST FAN
SPECIFICATION: BS 2573 MPI METHOD: N/A PARTS EXAMINED: Entire body RESULTS: No defect as at the time of inspection. Fit for use TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A
Name and address of equipment owner : Pacific Drilling
Address of premises where test / Examination was held: Pacific Bora
We hereby certify that on 08/08/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection. Fit for use Signature of Inspector: Conducting Examination Name of Inspector: OLATUNJI AKINLADE Conducting: Examination only
Revision No: 01
Doc No: JCI-C-V-01
JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: service@jcinternationalng.com Website: www.jcinternationalng.com
CERTIFICATE OF VISUAL EXAMINATION
STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998
Certificate No. 7545 Identification Number Qty
Date of Examination 08/08/2012
Examiner OLATUNJI AKINLADE TARE WT SWL
Qualifications LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Description of Equipment
Examination
FABRICATED PADEYE
BPEF-07
1
A Steel Construction Fabricated Pad Eye / Anchor Point
N/A
2 tonnes
N/A
N/A
07/02/13
LOCATION: BALLAST PUMP EXHAUST FAN
SPECIFICATION: BS 2573 MPI METHOD: N/A PARTS EXAMINED: Entire body RESULTS: No defect as at the time of inspection. Fit for use TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A
Name and address of equipment owner : Pacific Drilling
Address of premises where test / Examination was held: Pacific Bora
We hereby certify that on 08/08/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection. Fit for use Signature of Inspector: Conducting Examination Name of Inspector: OLATUNJI AKINLADE Conducting: Examination only
Revision No: 01
Doc No: JCI-C-V-01
JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: service@jcinternationalng.com Website: www.jcinternationalng.com
CERTIFICATE OF VISUAL EXAMINATION
STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998
Certificate No. 7546 Identification Number Qty
Date of Examination 08/08/2012
Examiner OLATUNJI AKINLADE TARE WT SWL
Qualifications LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Description of Equipment
Examination
FABRICATED PADEYE
BPEF-08
1
A Steel Construction Fabricated Pad Eye / Anchor Point
N/A
2 tonnes
N/A
N/A
07/02/13
LOCATION: BALLAST PUMP EXHAUST FAN
SPECIFICATION: BS 2573 MPI METHOD: N/A PARTS EXAMINED: Entire body RESULTS: No defect as at the time of inspection. Fit for use TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A
Name and address of equipment owner : Pacific Drilling
Address of premises where test / Examination was held: Pacific Bora
We hereby certify that on 08/08/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection. Fit for use Signature of Inspector: Conducting Examination Name of Inspector: OLATUNJI AKINLADE Conducting: Examination only
Revision No: 01
Doc No: JCI-C-V-01
JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: service@jcinternationalng.com Website: www.jcinternationalng.com
CERTIFICATE OF VISUAL EXAMINATION
STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998
Certificate No. 7547 Identification Number Qty
Date of Examination 08/08/2012
Examiner OLATUNJI AKINLADE TARE WT SWL
Qualifications LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Description of Equipment
Examination
FABRICATED PADEYE
BPEF-09
1
A Steel Construction Fabricated Pad Eye / Anchor Point
N/A
2 tonnes
N/A
N/A
07/02/13
LOCATION: BALLAST PUMP EXHAUST FAN
SPECIFICATION: BS 2573 MPI METHOD: N/A PARTS EXAMINED: Entire body RESULTS: No defect as at the time of inspection. Fit for use TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A
Name and address of equipment owner : Pacific Drilling
Address of premises where test / Examination was held: Pacific Bora
We hereby certify that on 08/08/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection. Fit for use Signature of Inspector: Conducting Examination Name of Inspector: OLATUNJI AKINLADE Conducting: Examination only
Revision No: 01
Doc No: JCI-C-V-01
JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: service@jcinternationalng.com Website: www.jcinternationalng.com
CERTIFICATE OF VISUAL EXAMINATION
STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998
Certificate No. 7548 Identification Number Qty
Date of Examination 08/08/2012
Examiner OLATUNJI AKINLADE TARE WT SWL
Qualifications LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Description of Equipment
Examination
FABRICATED PADEYE
BPEF-10
1
A Steel Construction Fabricated Pad Eye / Anchor Point
N/A
2 tonnes
N/A
N/A
07/02/13
LOCATION: BALLAST PUMP EXHAUST FAN
SPECIFICATION: BS 2573 MPI METHOD: N/A PARTS EXAMINED: Entire body RESULTS: No defect as at the time of inspection. Fit for use TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A
Name and address of equipment owner: Pacific Drilling
Address of premises where test / Examination was held: Pacific Bora
We hereby certify that on 08/08/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection. Fit for use Signature of Inspector: Conducting Examination Name of Inspector: OLATUNJI AKINLADE Conducting: Examination only
Revision No: 01
Doc No: JCI-C-V-01
JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: service@jcinternationalng.com Website: www.jcinternationalng.com
CERTIFICATE OF VISUAL EXAMINATION
STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998
Certificate No. 7549 Identification Number Qty
Date of Examination 08/08/2012
Examiner OLATUNJI AKINLADE TARE WT SWL
Qualifications LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Description of Equipment
Examination
FABRICATED PADEYE
BPEF-11
1
A Steel Construction Fabricated Pad Eye / Anchor Point
N/A
2 tonnes
N/A
N/A
07/02/13
LOCATION: BALLAST PUMP EXHAUST FAN
SPECIFICATION: BS 2573 MPI METHOD: N/A PARTS EXAMINED: Entire body RESULTS: No defect as at the time of inspection. Fit for use TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A
Name and address of equipment owner : Pacific Drilling
Address of premises where test / Examination was held: Pacific Bora
We hereby certify that on 08/08/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection. Fit for use Signature of Inspector: Conducting Examination Name of Inspector: OLATUNJI AKINLADE Conducting: Examination only
Revision No: 01
Doc No: JCI-C-V-01
JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: service@jcinternationalng.com Website: www.jcinternationalng.com
CERTIFICATE OF VISUAL EXAMINATION
STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998
Certificate No. 7550 Identification Number Qty
Date of Examination 08/08/2012
Examiner OLATUNJI AKINLADE TARE WT SWL
Qualifications LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Description of Equipment
Examination
FABRICATED PADEYE
BPEF-12
1
A Steel Construction Fabricated Pad Eye / Anchor Point
N/A
2 tonnes
N/A
N/A
07/02/13
LOCATION: BALLAST PUMP EXHAUST FAN
SPECIFICATION: BS 2573 MPI METHOD: N/A PARTS EXAMINED: Entire body RESULTS: No defect as at the time of inspection. Fit for use TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A
Name and address of equipment owner : Pacific Drilling
Address of premises where test / Examination was held: Pacific Bora
We hereby certify that on 08/08/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection. Fit for use Signature of Inspector: Conducting Examination Name of Inspector: OLATUNJI AKINLADE Conducting: Examination only
Revision No: 01
Doc No: JCI-C-V-01
JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: service@jcinternationalng.com Website: www.jcinternationalng.com
CERTIFICATE OF VISUAL EXAMINATION AND MPI
STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998
Certificate No. 7551
Date of Examination 06/08/2012
Examiner OLATUNJI AKINLADE
Qualifications LEEA, SNT LEVEL II MT, PT & UT
Identification Number
Description of Equipment
LIFTING POINT
PB-MH-01
Mouse Hole Lifting Points
SWL: 5 tonnes
Date of Next Examination: 05-02-13
LOCATION: PIPE DECK
SPECIFICATION: BS 2573 MPI METHOD: Wet Visible PARTS EXAMINED: Entire body RESULTS: No defect as at the time of inspection. Fit for use TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-020 White Contrast Aid Black Magnetic Ink
Name and address of equipment owner: Pacific Drilling
Address of premises where test / Examination was held: Pacific Bora
We hereby certify that on 06/08/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection. Fit for use Signature of Inspector: Conducting Examination Name of Inspector: OLATUNJI AKINLADE Conducting: Examination only
Revision No: 01
Doc No: JCI-C-VMPI-01
JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: service@jcinternationalng.com Website: www.jcinternationalng.com
CERTIFICATE OF VISUAL EXAMINATION
STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998
Certificate No. 7552 Identification Number Qty
Date of Examination 10/08/2012
Examiner OLATUNJI AKINLADE TARE WT SWL
Qualifications LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Description of Equipment
Examination
FABRICATED PADEYE
XPE-12
1
A Steel Construction Fabricated Pad Eye / Anchor Point
N/A
1 tonne
N/A
N/A
09/02/13
LOCATION: SACK STORE
SPECIFICATION: BS 2573 MPI METHOD: N/A PARTS EXAMINED: Entire body RESULTS: No defect as at the time of inspection. Fit for use TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A
Name and address of equipment owner: Pacific Drilling
Address of premises where test / Examination was held: Pacific Bora
We hereby certify that on 10/08/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection. Fit for use Signature of Inspector: Conducting Examination Name of Inspector: OLATUNJI AKINLADE Conducting: Examination only
Revision No: 01
Doc No: JCI-C-V-01
JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: service@jcinternationalng.com Website: www.jcinternationalng.com
CERTIFICATE OF VISUAL EXAMINATION
STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998
Certificate No. 7553 Identification Number Qty
Date of Examination 13/08/2012
Examiner OLATUNJI AKINLADE TARE WT SWL
Qualifications LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Description of Equipment
Examination
PADEYE
SP-046
1
Stanchion Pole Pad Eye
N/A
2 tonnes
N/A
N/A
12/02/13
LOCATION: PIPE DECK
SPECIFICATION: BS 2573 MPI METHOD: N/A PARTS EXAMINED: Entire body RESULTS: No defect as at the time of inspection. Fit for use TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A
Name and address of equipment owner : Pacific Drilling
Address of premises where test / Examination was held: Pacific Bora
We hereby certify that on 13/08/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection. Fit for use Signature of Inspector: Conducting Examination Name of Inspector: OLATUNJI AKINLADE Conducting: Examination only
Revision No: 01
Doc No: JCI-C-V-01
JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: service@jcinternationalng.com Website: www.jcinternationalng.com
CERTIFICATE OF VISUAL EXAMINATION
STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998
Certificate No. 7554 Identification Number Qty
Date of Examination 13/08/2012
Examiner OLATUNJI AKINLADE TARE WT SWL
Qualifications LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Description of Equipment
Examination
PADEYE
SP-055
1
Stanchion Pole Pad Eye
N/A
2 tonnes
N/A
N/A
12/02/13
LOCATION: PIPE DECK
SPECIFICATION: BS 2573 MPI METHOD: N/A PARTS EXAMINED: Entire body RESULTS: No defect as at the time of inspection. Fit for use TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A
Name and address of equipment owner : Pacific Drilling
Address of premises where test / Examination was held: Pacific Bora
We hereby certify that on 13/08/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection. Fit for use Signature of Inspector: Conducting Examination Name of Inspector: OLATUNJI AKINLADE Conducting: Examination only
Revision No: 01
Doc No: JCI-C-V-01
JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: service@jcinternationalng.com Website: www.jcinternationalng.com
CERTIFICATE OF VISUAL EXAMINATION
STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998
Certificate No. 7555 Identification Number Qty
Date of Examination 13/08/2012
Examiner OLATUNJI AKINLADE TARE WT SWL
Qualifications LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Description of Equipment
Examination
PADEYE
SP-054
1
Stanchion Pole Pad Eye
N/A
2 tonnes
N/A
N/A
12/02/13
LOCATION: PIPE DECK
SPECIFICATION: BS 2573 MPI METHOD: N/A PARTS EXAMINED: Entire body RESULTS: No defect as at the time of inspection. Fit for use TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A
Name and address of equipment owner : Pacific Drilling
Address of premises where test / Examination was held: Pacific Bora
We hereby certify that on 13/08/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection. Fit for use Signature of Inspector: Conducting Examination Name of Inspector: OLATUNJI AKINLADE Conducting: Examination only
Revision No: 01
Doc No: JCI-C-V-01
JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: service@jcinternationalng.com Website: www.jcinternationalng.com
CERTIFICATE OF VISUAL EXAMINATION
STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998
Certificate No. 7556 Identification Number Qty
Date of Examination 13/08/2012
Examiner OLATUNJI AKINLADE TARE WT SWL
Qualifications LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Description of Equipment
Examination
PADEYE
SP-052
1
Stanchion Pole Pad Eye
N/A
2 tonnes
N/A
N/A
12/02/13
LOCATION: PIPE DECK
SPECIFICATION: BS 2573 MPI METHOD: N/A PARTS EXAMINED: Entire body RESULTS: No defect as at the time of inspection. Fit for use TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A
Name and address of equipment owner : Pacific Drilling
Address of premises where test / Examination was held: Pacific Bora
We hereby certify that on 13/08/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection. Fit for use Signature of Inspector: Conducting Examination Name of Inspector: OLATUNJI AKINLADE Conducting: Examination only
Revision No: 01
Doc No: JCI-C-V-01
JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: service@jcinternationalng.com Website: www.jcinternationalng.com
CERTIFICATE OF VISUAL EXAMINATION
STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998
Certificate No. 7557 Identification Number Qty
Date of Examination 13/08/2012
Examiner OLATUNJI AKINLADE TARE WT SWL
Qualifications LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Description of Equipment
Examination
PADEYE
SP-053
1
Stanchion Pole Pad Eye
N/A
2 tonnes
N/A
N/A
12/02/13
LOCATION: PIPE DECK
SPECIFICATION: BS 2573 MPI METHOD: N/A PARTS EXAMINED: Entire body RESULTS: No defect as at the time of inspection. Fit for use TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A
Name and address of equipment owner : Pacific Drilling
Address of premises where test / Examination was held: Pacific Bora
We hereby certify that on 13/08/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection. Fit for use Signature of Inspector: Conducting Examination Name of Inspector: OLATUNJI AKINLADE Conducting: Examination only
Revision No: 01
Doc No: JCI-C-V-01
JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: service@jcinternationalng.com Website: www.jcinternationalng.com
CERTIFICATE OF VISUAL EXAMINATION
STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998
Certificate No. 7558 Identification Number Qty
Date of Examination 13/08/2012
Examiner OLATUNJI AKINLADE TARE WT SWL
Qualifications LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Description of Equipment
Examination
PADEYE
SP-074
1
Stanchion Pole Pad Eye
N/A
2 tonnes
N/A
N/A
12/02/13
LOCATION: PIPE DECK
SPECIFICATION: BS 2573 MPI METHOD: N/A PARTS EXAMINED: Entire body RESULTS: No defect as at the time of inspection. Fit for use TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A
Name and address of equipment owner : Pacific Drilling
Address of premises where test / Examination was held: Pacific Bora
We hereby certify that on 13/08/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection. Fit for use Signature of Inspector: Conducting Examination Name of Inspector: OLATUNJI AKINLADE Conducting: Examination only
Revision No: 01
Doc No: JCI-C-V-01
JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: service@jcinternationalng.com Website: www.jcinternationalng.com
CERTIFICATE OF VISUAL EXAMINATION
STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998
Certificate No. 7559 Identification Number Qty
Date of Examination 13/08/2012
Examiner OLATUNJI AKINLADE TARE WT SWL
Qualifications LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Description of Equipment
Examination
PADEYE
SP-076
1
Stanchion Pole Pad Eye
N/A
2 tonnes
N/A
N/A
12/02/13
LOCATION: PIPE DECK
SPECIFICATION: BS 2573 MPI METHOD: N/A PARTS EXAMINED: Entire body RESULTS: No defect as at the time of inspection. Fit for use TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A
Name and address of equipment owner : Pacific Drilling
Address of premises where test / Examination was held: Pacific Bora
We hereby certify that on 13/08/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection. Fit for use Signature of Inspector: Conducting Examination Name of Inspector: OLATUNJI AKINLADE Conducting: Examination only
Revision No: 01
Doc No: JCI-C-V-01
JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: service@jcinternationalng.com Website: www.jcinternationalng.com
CERTIFICATE OF VISUAL EXAMINATION
STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998
Certificate No. 7560 Identification Number Qty
Date of Examination 13/08/2012
Examiner OLATUNJI AKINLADE TARE WT SWL
Qualifications LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Description of Equipment
Examination
PADEYE
SP-075
1
Stanchion Pole Pad Eye
N/A
2 tonnes
N/A
N/A
12/02/13
LOCATION: PIPE DECK
SPECIFICATION: BS 2573 MPI METHOD: N/A PARTS EXAMINED: Entire body RESULTS: No defect as at the time of inspection. Fit for use TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A
Name and address of equipment owner: Pacific Drilling
Address of premises where test / Examination was held: Pacific Bora
We hereby certify that on 13/08/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection. Fit for use Signature of Inspector: Conducting Examination Name of Inspector: OLATUNJI AKINLADE Conducting: Examination only
Revision No: 01
Doc No: JCI-C-V-01
JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: service@jcinternationalng.com Website: www.jcinternationalng.com
CERTIFICATE OF VISUAL EXAMINATION
STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998
Certificate No. 7561 Identification Number Qty
Date of Examination 13/08/2012
Examiner OLATUNJI AKINLADE TARE WT SWL
Qualifications LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Description of Equipment
Examination
PADEYE
SP-073
1
Stanchion Pole Pad Eye
N/A
2 tonnes
N/A
N/A
12/02/13
LOCATION: PIPE DECK
SPECIFICATION: BS 2573 MPI METHOD: N/A PARTS EXAMINED: Entire body RESULTS: No defect as at the time of inspection. Fit for use TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A
Name and address of equipment owner : Pacific Drilling
Address of premises where test / Examination was held: Pacific Bora
We hereby certify that on 13/08/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection. Fit for use Signature of Inspector: Conducting Examination Name of Inspector: OLATUNJI AKINLADE Conducting: Examination only
Revision No: 01
Doc No: JCI-C-V-01
JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: service@jcinternationalng.com Website: www.jcinternationalng.com
CERTIFICATE OF VISUAL EXAMINATION
STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998
Certificate No. 7562 Identification Number Qty
Date of Examination 13/08/2012
Examiner OLATUNJI AKINLADE TARE WT SWL
Qualifications LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Description of Equipment
Examination
PADEYE
SP-057
1
Stanchion Pole Pad Eye
N/A
2 tonnes
N/A
N/A
12/02/13
LOCATION: PIPE DECK
SPECIFICATION: BS 2573 MPI METHOD: N/A PARTS EXAMINED: Entire body RESULTS: No defect as at the time of inspection. Fit for use TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A
Name and address of equipment owner : Pacific Drilling
Address of premises where test / Examination was held: Pacific Bora
We hereby certify that on 13/08/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection. Fit for use Signature of Inspector: Conducting Examination Name of Inspector: OLATUNJI AKINLADE Conducting: Examination only
Revision No: 01
Doc No: JCI-C-V-01
JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: service@jcinternationalng.com Website: www.jcinternationalng.com
CERTIFICATE OF VISUAL EXAMINATION
STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998
Certificate No. 7563 Identification Number Qty
Date of Examination 13/08/2012
Examiner OLATUNJI AKINLADE TARE WT SWL
Qualifications LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Description of Equipment
Examination
PADEYE
SP-058
1
Stanchion Pole Pad Eye
N/A
2 tonnes
N/A
N/A
12/02/13
LOCATION: PIPE DECK
SPECIFICATION: BS 2573 MPI METHOD: N/A PARTS EXAMINED: Entire body RESULTS: No defect as at the time of inspection. Fit for use TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A
Name and address of equipment owner : Pacific Drilling
Address of premises where test / Examination was held: Pacific Bora
We hereby certify that on 13/08/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection. Fit for use Signature of Inspector: Conducting Examination Name of Inspector: OLATUNJI AKINLADE Conducting: Examination only
Revision No: 01
Doc No: JCI-C-V-01
JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: service@jcinternationalng.com Website: www.jcinternationalng.com
CERTIFICATE OF VISUAL EXAMINATION
STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998
Certificate No. 7564 Identification Number Qty
Date of Examination 13/08/2012
Examiner OLATUNJI AKINLADE TARE WT SWL
Qualifications LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Description of Equipment
Examination
PADEYE
SP-059
1
Stanchion Pole Pad Eye
N/A
2 tonnes
N/A
N/A
12/02/13
LOCATION: PIPE DECK
SPECIFICATION: BS 2573 MPI METHOD: N/A PARTS EXAMINED: Entire body RESULTS: No defect as at the time of inspection. Fit for use TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A
Name and address of equipment owner : Pacific Drilling
Address of premises where test / Examination was held: Pacific Bora
We hereby certify that on 13/08/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection. Fit for use Signature of Inspector: Conducting Examination Name of Inspector: OLATUNJI AKINLADE Conducting: Examination only
Revision No: 01
Doc No: JCI-C-V-01
JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: service@jcinternationalng.com Website: www.jcinternationalng.com
CERTIFICATE OF VISUAL EXAMINATION
STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998
Certificate No. 7565 Identification Number Qty
Date of Examination 13/08/2012
Examiner OLATUNJI AKINLADE TARE WT SWL
Qualifications LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Description of Equipment
Examination
PADEYE
SP-051
1
Stanchion Pole Pad Eye
N/A
2 tonnes
N/A
N/A
12/02/13
LOCATION: PIPE DECK
SPECIFICATION: BS 2573 MPI METHOD: N/A PARTS EXAMINED: Entire body RESULTS: No defect as at the time of inspection. Fit for use TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A
Name and address of equipment owner : Pacific Drilling
Address of premises where test / Examination was held: Pacific Bora
We hereby certify that on 13/08/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection. Fit for use Signature of Inspector: Conducting Examination Name of Inspector: OLATUNJI AKINLADE Conducting: Examination only
Revision No: 01
Doc No: JCI-C-V-01
JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: service@jcinternationalng.com Website: www.jcinternationalng.com
CERTIFICATE OF VISUAL EXAMINATION
STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998
Certificate No. 7566 Identification Number Qty
Date of Examination 13/08/2012
Examiner OLATUNJI AKINLADE TARE WT SWL
Qualifications LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Description of Equipment
Examination
PADEYE
SP-042
1
Stanchion Pole Pad Eye
N/A
2 tonnes
N/A
N/A
12/02/13
LOCATION: PIPE DECK
SPECIFICATION: BS 2573 MPI METHOD: N/A PARTS EXAMINED: Entire body RESULTS: No defect as at the time of inspection. Fit for use TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A
Name and address of equipment owner : Pacific Drilling
Address of premises where test / Examination was held: Pacific Bora
We hereby certify that on 13/08/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection. Fit for use Signature of Inspector: Conducting Examination Name of Inspector: OLATUNJI AKINLADE Conducting: Examination only
Revision No: 01
Doc No: JCI-C-V-01
JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: service@jcinternationalng.com Website: www.jcinternationalng.com
CERTIFICATE OF VISUAL EXAMINATION
STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998
Certificate No. 7567 Identification Number Qty
Date of Examination 13/08/2012
Examiner OLATUNJI AKINLADE TARE WT SWL
Qualifications LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Description of Equipment
Examination
PADEYE
SP-043
1
Stanchion Pole Pad Eye
N/A
2 tonnes
N/A
N/A
12/02/13
LOCATION: PIPE DECK
SPECIFICATION: BS 2573 MPI METHOD: N/A PARTS EXAMINED: Entire body RESULTS: No defect as at the time of inspection. Fit for use TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A
Name and address of equipment owner : Pacific Drilling
Address of premises where test / Examination was held: Pacific Bora
We hereby certify that on 13/08/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection. Fit for use Signature of Inspector: Conducting Examination Name of Inspector: OLATUNJI AKINLADE Conducting: Examination only
Revision No: 01
Doc No: JCI-C-V-01
JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: service@jcinternationalng.com Website: www.jcinternationalng.com
CERTIFICATE OF VISUAL EXAMINATION
STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998
Certificate No. 7568 Identification Number Qty
Date of Examination 13/08/2012
Examiner OLATUNJI AKINLADE TARE WT SWL
Qualifications LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Description of Equipment
Examination
PADEYE
SP-044
1
Stanchion Pole Pad Eye
N/A
2 tonnes
N/A
N/A
12/02/13
LOCATION: PIPE DECK
SPECIFICATION: BS 2573 MPI METHOD: N/A PARTS EXAMINED: Entire body RESULTS: No defect as at the time of inspection. Fit for use TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A
Name and address of equipment owner: Pacific Drilling
Address of premises where test / Examination was held: Pacific Bora
We hereby certify that on 13/08/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection. Fit for use Signature of Inspector: Conducting Examination Name of Inspector: OLATUNJI AKINLADE Conducting: Examination only
Revision No: 01
Doc No: JCI-C-V-01
JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: service@jcinternationalng.com Website: www.jcinternationalng.com
CERTIFICATE OF VISUAL EXAMINATION
STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998
Certificate No. 7569 Identification Number Qty
Date of Examination 13/08/2012
Examiner OLATUNJI AKINLADE TARE WT SWL
Qualifications LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Description of Equipment
Examination
PADEYE
SP-045
1
Stanchion Pole Pad Eye
N/A
2 tonnes
N/A
N/A
12/02/13
LOCATION: PIPE DECK
SPECIFICATION: BS 2573 MPI METHOD: N/A PARTS EXAMINED: Entire body RESULTS: No defect as at the time of inspection. Fit for use TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A
Name and address of equipment owner : Pacific Drilling
Address of premises where test / Examination was held: Pacific Bora
We hereby certify that on 13/08/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection. Fit for use Signature of Inspector: Conducting Examination Name of Inspector: OLATUNJI AKINLADE Conducting: Examination only
Revision No: 01
Doc No: JCI-C-V-01
JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: service@jcinternationalng.com Website: www.jcinternationalng.com
CERTIFICATE OF VISUAL EXAMINATION
STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998
Certificate No. 7570 Identification Number Qty
Date of Examination 13/08/2012
Examiner OLATUNJI AKINLADE TARE WT SWL
Qualifications LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Description of Equipment
Examination
PADEYE
SP-049
1
Stanchion Pole Pad Eye
N/A
2 tonnes
N/A
N/A
12/02/13
LOCATION: PIPE DECK
SPECIFICATION: BS 2573 MPI METHOD: N/A PARTS EXAMINED: Entire body RESULTS: No defect as at the time of inspection. Fit for use TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A
Name and address of equipment owner : Pacific Drilling
Address of premises where test / Examination was held: Pacific Bora
We hereby certify that on 13/08/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection. Fit for use Signature of Inspector: Conducting Examination Name of Inspector: OLATUNJI AKINLADE Conducting: Examination only
Revision No: 01
Doc No: JCI-C-V-01
JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: service@jcinternationalng.com Website: www.jcinternationalng.com
CERTIFICATE OF VISUAL EXAMINATION
STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998
Certificate No. 7571 Identification Number Qty
Date of Examination 13/08/2012
Examiner OLATUNJI AKINLADE TARE WT SWL
Qualifications LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Description of Equipment
Examination
PADEYE
SP-048
1
Stanchion Pole Pad Eye
N/A
2 tonnes
N/A
N/A
12/02/13
LOCATION: PIPE DECK
SPECIFICATION: BS 2573 MPI METHOD: N/A PARTS EXAMINED: Entire body RESULTS: No defect as at the time of inspection. Fit for use TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A
Name and address of equipment owner : Pacific Drilling
Address of premises where test / Examination was held: Pacific Bora
We hereby certify that on 13/08/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection. Fit for use Signature of Inspector: Conducting Examination Name of Inspector: OLATUNJI AKINLADE Conducting: Examination only
Revision No: 01
Doc No: JCI-C-V-01
JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: service@jcinternationalng.com Website: www.jcinternationalng.com
CERTIFICATE OF VISUAL EXAMINATION
STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998
Certificate No. 7572 Identification Number Qty
Date of Examination 13/08/2012
Examiner OLATUNJI AKINLADE TARE WT SWL
Qualifications LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Description of Equipment
Examination
PADEYE
SP-050
1
Stanchion Pole Pad Eye
N/A
2 tonnes
N/A
N/A
12/02/13
LOCATION: PIPE DECK
SPECIFICATION: BS 2573 MPI METHOD: N/A PARTS EXAMINED: Entire body RESULTS: No defect as at the time of inspection. Fit for use TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A
Name and address of equipment owner : Pacific Drilling
Address of premises where test / Examination was held: Pacific Bora
We hereby certify that on 13/08/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection. Fit for use Signature of Inspector: Conducting Examination Name of Inspector: OLATUNJI AKINLADE Conducting: Examination only
Revision No: 01
Doc No: JCI-C-V-01
JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: service@jcinternationalng.com Website: www.jcinternationalng.com
CERTIFICATE OF VISUAL EXAMINATION
STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998
Certificate No. 7573 Identification Number Qty
Date of Examination 13/08/2012
Examiner OLATUNJI AKINLADE TARE WT SWL
Qualifications LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Description of Equipment
Examination
PADEYE
SP-047
1
Stanchion Pole Pad Eye
N/A
2 tonnes
N/A
N/A
12/02/13
LOCATION: PIPE DECK
SPECIFICATION: BS 2573 MPI METHOD: N/A PARTS EXAMINED: Entire body RESULTS: No defect as at the time of inspection. Fit for use TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A
Name and address of equipment owner : Pacific Drilling
Address of premises where test / Examination was held: Pacific Bora
We hereby certify that on 13/08/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection. Fit for use Signature of Inspector: Conducting Examination Name of Inspector: OLATUNJI AKINLADE Conducting: Examination only
Revision No: 01
Doc No: JCI-C-V-01
JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: service@jcinternationalng.com Website: www.jcinternationalng.com
CERTIFICATE OF VISUAL EXAMINATION
STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998
Certificate No. 7574 Identification Number Qty
Date of Examination 13/08/2012
Examiner OLATUNJI AKINLADE TARE WT SWL
Qualifications LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Description of Equipment
Examination
PADEYE
SP-070
1
Stanchion Pole Pad Eye
N/A
2 tonnes
N/A
N/A
12/02/13
LOCATION: PIPE DECK
SPECIFICATION: BS 2573 MPI METHOD: N/A PARTS EXAMINED: Entire body RESULTS: No defect as at the time of inspection. Fit for use TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A
Name and address of equipment owner : Pacific Drilling
Address of premises where test / Examination was held: Pacific Bora
We hereby certify that on 13/08/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection. Fit for use Signature of Inspector: Conducting Examination Name of Inspector: OLATUNJI AKINLADE Conducting: Examination only
Revision No: 01
Doc No: JCI-C-V-01
JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: service@jcinternationalng.com Website: www.jcinternationalng.com
CERTIFICATE OF VISUAL EXAMINATION
STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998
Certificate No. 7575 Identification Number Qty
Date of Examination 13/08/2012
Examiner OLATUNJI AKINLADE TARE WT SWL
Qualifications LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Description of Equipment
Examination
PADEYE
SP-071
1
Stanchion Pole Pad Eye
N/A
2 tonnes
N/A
N/A
12/02/13
LOCATION: PIPE DECK
SPECIFICATION: BS 2573 MPI METHOD: N/A PARTS EXAMINED: Entire body RESULTS: No defect as at the time of inspection. Fit for use TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A
Name and address of equipment owner : Pacific Drilling
Address of premises where test / Examination was held: Pacific Bora
We hereby certify that on 13/08/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection. Fit for use Signature of Inspector: Conducting Examination Name of Inspector: OLATUNJI AKINLADE Conducting: Examination only
Revision No: 01
Doc No: JCI-C-V-01
JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: service@jcinternationalng.com Website: www.jcinternationalng.com
CERTIFICATE OF VISUAL EXAMINATION
STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998
Certificate No. 7576 Identification Number Qty
Date of Examination 13/08/2012
Examiner OLATUNJI AKINLADE TARE WT SWL
Qualifications LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Description of Equipment
Examination
PADEYE
SP-072
1
Stanchion Pole Pad Eye
N/A
2 tonnes
N/A
N/A
12/02/13
LOCATION: PIPE DECK
SPECIFICATION: BS 2573 MPI METHOD: N/A PARTS EXAMINED: Entire body RESULTS: No defect as at the time of inspection. Fit for use TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A
Name and address of equipment owner: Pacific Drilling
Address of premises where test / Examination was held: Pacific Bora
We hereby certify that on 13/08/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection. Fit for use Signature of Inspector: Conducting Examination Name of Inspector: OLATUNJI AKINLADE Conducting: Examination only
Revision No: 01
Doc No: JCI-C-V-01
JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: service@jcinternationalng.com Website: www.jcinternationalng.com
CERTIFICATE OF VISUAL EXAMINATION
STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998
Certificate No. 7577 Identification Number Qty
Date of Examination 13/08/2012
Examiner OLATUNJI AKINLADE TARE WT SWL
Qualifications LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Description of Equipment
Examination
PADEYE
SP-066
1
Stanchion Pole Pad Eye
N/A
2 tonnes
N/A
N/A
12/02/13
LOCATION: PIPE DECK
SPECIFICATION: BS 2573 MPI METHOD: N/A PARTS EXAMINED: Entire body RESULTS: No defect as at the time of inspection. Fit for use TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A
Name and address of equipment owner : Pacific Drilling
Address of premises where test / Examination was held: Pacific Bora
We hereby certify that on 13/08/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection. Fit for use Signature of Inspector: Conducting Examination Name of Inspector: OLATUNJI AKINLADE Conducting: Examination only
Revision No: 01
Doc No: JCI-C-V-01
JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: service@jcinternationalng.com Website: www.jcinternationalng.com
CERTIFICATE OF VISUAL EXAMINATION
STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998
Certificate No. 7578 Identification Number Qty
Date of Examination 13/08/2012
Examiner OLATUNJI AKINLADE TARE WT SWL
Qualifications LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Description of Equipment
Examination
PADEYE
SP-065
1
Stanchion Pole Pad Eye
N/A
2 tonnes
N/A
N/A
12/02/13
LOCATION: PIPE DECK
SPECIFICATION: BS 2573 MPI METHOD: N/A PARTS EXAMINED: Entire body RESULTS: No defect as at the time of inspection. Fit for use TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A
Name and address of equipment owner : Pacific Drilling
Address of premises where test / Examination was held: Pacific Bora
We hereby certify that on 13/08/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection. Fit for use Signature of Inspector: Conducting Examination Name of Inspector: OLATUNJI AKINLADE Conducting: Examination only
Revision No: 01
Doc No: JCI-C-V-01
JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: service@jcinternationalng.com Website: www.jcinternationalng.com
CERTIFICATE OF VISUAL EXAMINATION
STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998
Certificate No. 7579 Identification Number Qty
Date of Examination 13/08/2012
Examiner OLATUNJI AKINLADE TARE WT SWL
Qualifications LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Description of Equipment
Examination
PADEYE
SP-064
1
Stanchion Pole Pad Eye
N/A
2 tonnes
N/A
N/A
12/02/13
LOCATION: PIPE DECK
SPECIFICATION: BS 2573 MPI METHOD: N/A PARTS EXAMINED: Entire body RESULTS: No defect as at the time of inspection. Fit for use TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A
Name and address of equipment owner : Pacific Drilling
Address of premises where test / Examination was held: Pacific Bora
We hereby certify that on 13/08/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection. Fit for use Signature of Inspector: Conducting Examination Name of Inspector: OLATUNJI AKINLADE Conducting: Examination only
Revision No: 01
Doc No: JCI-C-V-01
JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: service@jcinternationalng.com Website: www.jcinternationalng.com
CERTIFICATE OF VISUAL EXAMINATION
STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998
Certificate No. 7580 Identification Number Qty
Date of Examination 13/08/2012
Examiner OLATUNJI AKINLADE TARE WT SWL
Qualifications LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Description of Equipment
Examination
PADEYE
SP-062
1
Stanchion Pole Pad Eye
N/A
2 tonnes
N/A
N/A
12/02/13
LOCATION: PIPE DECK
SPECIFICATION: BS 2573 MPI METHOD: N/A PARTS EXAMINED: Entire body RESULTS: No defect as at the time of inspection. Fit for use TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A
Name and address of equipment owner : Pacific Drilling
Address of premises where test / Examination was held: Pacific Bora
We hereby certify that on 13/08/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection. Fit for use Signature of Inspector: Conducting Examination Name of Inspector: OLATUNJI AKINLADE Conducting: Examination only
Revision No: 01
Doc No: JCI-C-V-01
JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: service@jcinternationalng.com Website: www.jcinternationalng.com
CERTIFICATE OF VISUAL EXAMINATION
STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998
Certificate No. 7581 Identification Number Qty
Date of Examination 13/08/2012
Examiner OLATUNJI AKINLADE TARE WT SWL
Qualifications LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Description of Equipment
Examination
PADEYE
SP-063
1
Stanchion Pole Pad Eye
N/A
2 tonnes
N/A
N/A
12/02/13
LOCATION: PIPE DECK
SPECIFICATION: BS 2573 MPI METHOD: N/A PARTS EXAMINED: Entire body RESULTS: No defect as at the time of inspection. Fit for use TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A
Name and address of equipment owner : Pacific Drilling
Address of premises where test / Examination was held: Pacific Bora
We hereby certify that on 13/08/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection. Fit for use Signature of Inspector: Conducting Examination Name of Inspector: OLATUNJI AKINLADE Conducting: Examination only
Revision No: 01
Doc No: JCI-C-V-01
JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: service@jcinternationalng.com Website: www.jcinternationalng.com
CERTIFICATE OF VISUAL EXAMINATION
STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998
Certificate No. 7582 Identification Number Qty
Date of Examination 13/08/2012
Examiner OLATUNJI AKINLADE TARE WT SWL
Qualifications LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Description of Equipment
Examination
PADEYE
SP-060
1
Stanchion Pole Pad Eye
N/A
2 tonnes
N/A
N/A
12/02/13
LOCATION: PIPE DECK
SPECIFICATION: BS 2573 MPI METHOD: N/A PARTS EXAMINED: Entire body RESULTS: No defect as at the time of inspection. Fit for use TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A
Name and address of equipment owner : Pacific Drilling
Address of premises where test / Examination was held: Pacific Bora
We hereby certify that on 13/08/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection. Fit for use Signature of Inspector: Conducting Examination Name of Inspector: OLATUNJI AKINLADE Conducting: Examination only
Revision No: 01
Doc No: JCI-C-V-01
JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: service@jcinternationalng.com Website: www.jcinternationalng.com
CERTIFICATE OF VISUAL EXAMINATION
STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998
Certificate No. 7583 Identification Number Qty
Date of Examination 13/08/2012
Examiner OLATUNJI AKINLADE TARE WT SWL
Qualifications LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Description of Equipment
Examination
PADEYE
SP-061
1
Stanchion Pole Pad Eye
N/A
2 tonnes
N/A
N/A
12/02/13
LOCATION: PIPE DECK
SPECIFICATION: BS 2573 MPI METHOD: N/A PARTS EXAMINED: Entire body RESULTS: No defect as at the time of inspection. Fit for use TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A
Name and address of equipment owner : Pacific Drilling
Address of premises where test / Examination was held: Pacific Bora
We hereby certify that on 13/08/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection. Fit for use Signature of Inspector: Conducting Examination Name of Inspector: OLATUNJI AKINLADE Conducting: Examination only
Revision No: 01
Doc No: JCI-C-V-01
JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: service@jcinternationalng.com Website: www.jcinternationalng.com
CERTIFICATE OF VISUAL EXAMINATION
STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998
Certificate No. 7584 Identification Number Qty
Date of Examination 13/08/2012
Examiner OLATUNJI AKINLADE TARE WT SWL
Qualifications LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Description of Equipment
Examination
PADEYE
SP-056
1
Stanchion Pole Pad Eye
N/A
2 tonnes
N/A
N/A
12/02/13
LOCATION: PIPE DECK
SPECIFICATION: BS 2573 MPI METHOD: N/A PARTS EXAMINED: Entire body RESULTS: No defect as at the time of inspection. Fit for use TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A
Name and address of equipment owner: Pacific Drilling
Address of premises where test / Examination was held: Pacific Bora
We hereby certify that on 13/08/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection. Fit for use Signature of Inspector: Conducting Examination Name of Inspector: OLATUNJI AKINLADE Conducting: Examination only
Revision No: 01
Doc No: JCI-C-V-01
JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: service@jcinternationalng.com Website: www.jcinternationalng.com
CERTIFICATE OF VISUAL EXAMINATION
STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998
Certificate No. 7585 Identification Number Qty
Date of Examination 13/08/2012
Examiner OLATUNJI AKINLADE TARE WT SWL
Qualifications LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Description of Equipment
Examination
PADEYE
SP-068
1
Stanchion Pole Pad Eye
N/A
2 tonnes
N/A
N/A
12/02/13
LOCATION: PIPE DECK
SPECIFICATION: BS 2573 MPI METHOD: N/A PARTS EXAMINED: Entire body RESULTS: No defect as at the time of inspection. Fit for use TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A
Name and address of equipment owner : Pacific Drilling
Address of premises where test / Examination was held: Pacific Bora
We hereby certify that on 13/08/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection. Fit for use Signature of Inspector: Conducting Examination Name of Inspector: OLATUNJI AKINLADE Conducting: Examination only
Revision No: 01
Doc No: JCI-C-V-01
JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: service@jcinternationalng.com Website: www.jcinternationalng.com
CERTIFICATE OF VISUAL EXAMINATION
STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998
Certificate No. 7586 Identification Number Qty
Date of Examination 13/08/2012
Examiner OLATUNJI AKINLADE TARE WT SWL
Qualifications LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Description of Equipment
Examination
PADEYE
SP-069
1
Stanchion Pole Pad Eye
N/A
2 tonnes
N/A
N/A
12/02/13
LOCATION: PIPE DECK
SPECIFICATION: BS 2573 MPI METHOD: N/A PARTS EXAMINED: Entire body RESULTS: No defect as at the time of inspection. Fit for use TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A
Name and address of equipment owner : Pacific Drilling
Address of premises where test / Examination was held: Pacific Bora
We hereby certify that on 13/08/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection. Fit for use Signature of Inspector: Conducting Examination Name of Inspector: OLATUNJI AKINLADE Conducting: Examination only
Revision No: 01
Doc No: JCI-C-V-01
JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: service@jcinternationalng.com Website: www.jcinternationalng.com
CERTIFICATE OF VISUAL EXAMINATION
STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998
Certificate No. 7587 Identification Number Qty
Date of Examination 13/08/2012
Examiner OLATUNJI AKINLADE TARE WT SWL
Qualifications LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Description of Equipment
Examination
PADEYE
SP-067
1
Stanchion Pole Pad Eye
N/A
2 tonnes
N/A
N/A
12/02/13
LOCATION: PIPE DECK
SPECIFICATION: BS 2573 MPI METHOD: N/A PARTS EXAMINED: Entire body RESULTS: No defect as at the time of inspection. Fit for use TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A
Name and address of equipment owner : Pacific Drilling
Address of premises where test / Examination was held: Pacific Bora
We hereby certify that on 13/08/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection. Fit for use Signature of Inspector: Conducting Examination Name of Inspector: OLATUNJI AKINLADE Conducting: Examination only
Revision No: 01
Doc No: JCI-C-V-01
JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: service@jcinternationalng.com Website: www.jcinternationalng.com
CERTIFICATE OF VISUAL EXAMINATION
STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998
Certificate No. 7588 Identification Number Qty
Date of Examination 16/08/2012
Examiner OLATUNJI AKINLADE TARE WT SWL
Qualifications LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Description of Equipment
Examination
FABRICATED PADEYE
XPE-21
1
A Steel Construction Fabricated Pad Eye / Anchor Point
N/A
1 tonne
N/A
N/A
15/02/13
LOCATION: RISER DECK
SPECIFICATION: BS 2573 MPI METHOD: N/A PARTS EXAMINED: Entire body RESULTS: No defect as at the time of inspection. Fit for use TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A
Name and address of equipment owner : Pacific Drilling
Address of premises where test / Examination was held: Pacific Bora
We hereby certify that on 16/08/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection. Fit for use Signature of Inspector: Conducting Examination Name of Inspector: OLATUNJI AKINLADE Conducting: Examination only
Revision No: 01
Doc No: JCI-C-V-01
JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: service@jcinternationalng.com Website: www.jcinternationalng.com
CERTIFICATE OF VISUAL EXAMINATION
STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998
Certificate No. 7589 Identification Number Qty
Date of Examination 16/08/2012
Examiner OLATUNJI AKINLADE TARE WT SWL
Qualifications LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Description of Equipment
Examination
FABRICATED PADEYE
XPE-22
1
A Steel Construction Fabricated Pad Eye / Anchor Point
N/A
1 tonne
N/A
N/A
15/02/13
LOCATION: RISER DECK
SPECIFICATION: BS 2573 MPI METHOD: N/A PARTS EXAMINED: Entire body RESULTS: No defect as at the time of inspection. Fit for use TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A
Name and address of equipment owner : Pacific Drilling
Address of premises where test / Examination was held: Pacific Bora
We hereby certify that on 16/08/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection. Fit for use Signature of Inspector: Conducting Examination Name of Inspector: OLATUNJI AKINLADE Conducting: Examination only
Revision No: 01
Doc No: JCI-C-V-01
JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: service@jcinternationalng.com Website: www.jcinternationalng.com
CERTIFICATE OF VISUAL EXAMINATION
STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998
Certificate No. 7590 Identification Number Qty
Date of Examination 16/08/2012
Examiner OLATUNJI AKINLADE TARE WT SWL
Qualifications LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Description of Equipment
Examination
FABRICATED PADEYE
XPE-13
1
A Steel Construction Fabricated Pad Eye / Anchor Point
N/A
3 tonnes
N/A
N/A
15/02/13
LOCATION: RISER DECK
SPECIFICATION: BS 2573 MPI METHOD: N/A PARTS EXAMINED: Entire body RESULTS: No defect as at the time of inspection. Fit for use TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A
Name and address of equipment owner : Pacific Drilling
Address of premises where test / Examination was held: Pacific Bora
We hereby certify that on 16/08/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection. Fit for use Signature of Inspector: Conducting Examination Name of Inspector: OLATUNJI AKINLADE Conducting: Examination only
Revision No: 01
Doc No: JCI-C-V-01
JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: service@jcinternationalng.com Website: www.jcinternationalng.com
CERTIFICATE OF VISUAL EXAMINATION
STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998
Certificate No. 7591 Identification Number Qty
Date of Examination 16/08/2012
Examiner OLATUNJI AKINLADE TARE WT SWL
Qualifications LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Description of Equipment
Examination
FABRICATED PADEYE
XPE-14
1
A Steel Construction Fabricated Pad Eye / Anchor Point
N/A
3 tonnes
N/A
N/A
15/02/13
LOCATION: RISER DECK
SPECIFICATION: BS 2573 MPI METHOD: N/A PARTS EXAMINED: Entire body RESULTS: No defect as at the time of inspection. Fit for use TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A
Name and address of equipment owner : Pacific Drilling
Address of premises where test / Examination was held: Pacific Bora
We hereby certify that on 16/08/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection. Fit for use Signature of Inspector: Conducting Examination Name of Inspector: OLATUNJI AKINLADE Conducting: Examination only
Revision No: 01
Doc No: JCI-C-V-01
JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: service@jcinternationalng.com Website: www.jcinternationalng.com
CERTIFICATE OF VISUAL EXAMINATION
STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998
Certificate No. 7592 Identification Number Qty
Date of Examination 16/08/2012
Examiner OLATUNJI AKINLADE TARE WT SWL
Qualifications LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Description of Equipment
Examination
FABRICATED PADEYE
XPE-15
1
A Steel Construction Fabricated Pad Eye / Anchor Point
N/A
3 tonnes
N/A
N/A
15/02/13
LOCATION: RISER DECK
SPECIFICATION: BS 2573 MPI METHOD: N/A PARTS EXAMINED: Entire body RESULTS: No defect as at the time of inspection. Fit for use TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A
Name and address of equipment owner : Pacific Drilling
Address of premises where test / Examination was held: Pacific Bora
We hereby certify that on 16/08/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection. Fit for use Signature of Inspector: Conducting Examination Name of Inspector: OLATUNJI AKINLADE Conducting: Examination only
Revision No: 01
Doc No: JCI-C-V-01
JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: service@jcinternationalng.com Website: www.jcinternationalng.com
CERTIFICATE OF VISUAL EXAMINATION
STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998
Certificate No. 7593 Identification Number Qty
Date of Examination 16/08/2012
Examiner OLATUNJI AKINLADE TARE WT SWL
Qualifications LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Description of Equipment
Examination
FABRICATED PADEYE
XPE-16
1
A Steel Construction Fabricated Pad Eye / Anchor Point
N/A
3 tonnes
N/A
N/A
15/02/13
LOCATION: RISER DECK
SPECIFICATION: BS 2573 MPI METHOD: N/A PARTS EXAMINED: Entire body RESULTS: No defect as at the time of inspection. Fit for use TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A
Name and address of equipment owner : Pacific Drilling
Address of premises where test / Examination was held: Pacific Bora
We hereby certify that on 16/08/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection. Fit for use Signature of Inspector: Conducting Examination Name of Inspector: OLATUNJI AKINLADE Conducting: Examination only
Revision No: 01
Doc No: JCI-C-V-01
JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: service@jcinternationalng.com Website: www.jcinternationalng.com
CERTIFICATE OF VISUAL EXAMINATION
STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998
Certificate No. 7594 Identification Number Qty
Date of Examination 16/08/2012
Examiner OLATUNJI AKINLADE TARE WT SWL
Qualifications LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Description of Equipment
Examination
FABRICATED PADEYE
XPE-17
1
A Steel Construction Fabricated Pad Eye / Anchor Point
N/A
3 tonnes
N/A
N/A
15/02/13
LOCATION: RISER DECK
SPECIFICATION: BS 2573 MPI METHOD: N/A PARTS EXAMINED: Entire body RESULTS: No defect as at the time of inspection. Fit for use TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A
Name and address of equipment owner: Pacific Drilling
Address of premises where test / Examination was held: Pacific Bora
We hereby certify that on 16/08/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection. Fit for use Signature of Inspector: Conducting Examination Name of Inspector: OLATUNJI AKINLADE Conducting: Examination only
Revision No: 01
Doc No: JCI-C-V-01
JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: service@jcinternationalng.com Website: www.jcinternationalng.com
CERTIFICATE OF VISUAL EXAMINATION
STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998
Certificate No. 7595 Identification Number Qty
Date of Examination 16/08/2012
Examiner OLATUNJI AKINLADE TARE WT SWL
Qualifications LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Description of Equipment
Examination
FABRICATED PADEYE
XPE-18
1
A Steel Construction Fabricated Pad Eye / Anchor Point
N/A
3 tonnes
N/A
N/A
15/02/13
LOCATION: RISER DECK
SPECIFICATION: BS 2573 MPI METHOD: N/A PARTS EXAMINED: Entire body RESULTS: No defect as at the time of inspection. Fit for use TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A
Name and address of equipment owner: Pacific Drilling
Address of premises where test / Examination was held: Pacific Bora
We hereby certify that on 16/08/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection. Fit for use Signature of Inspector: Conducting Examination Name of Inspector: OLATUNJI AKINLADE Conducting: Examination only
Revision No: 01
Doc No: JCI-C-V-01
JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: service@jcinternationalng.com Website: www.jcinternationalng.com
CERTIFICATE OF VISUAL EXAMINATION
STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998
Certificate No. 7596 Identification Number Qty
Date of Examination 16/08/2012
Examiner OLATUNJI AKINLADE TARE WT SWL
Qualifications LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Description of Equipment
Examination
FABRICATED PADEYE
XPE-19
1
A Steel Construction Fabricated Pad Eye / Anchor Point
N/A
3 tonnes
N/A
N/A
15/02/13
LOCATION: RISER DECK
SPECIFICATION: BS 2573 MPI METHOD: N/A PARTS EXAMINED: Entire body RESULTS: No defect as at the time of inspection. Fit for use TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A
Name and address of equipment owner: Pacific Drilling
Address of premises where test / Examination was held: Pacific Bora
We hereby certify that on 16/08/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection. Fit for use Signature of Inspector: Conducting Examination Name of Inspector: OLATUNJI AKINLADE Conducting: Examination only
Revision No: 01
Doc No: JCI-C-V-01
JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: service@jcinternationalng.com Website: www.jcinternationalng.com
CERTIFICATE OF VISUAL EXAMINATION
STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998
Certificate No. 7597 Identification Number Qty
Date of Examination 16/08/2012
Examiner OLATUNJI AKINLADE TARE WT SWL
Qualifications LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Description of Equipment
Examination
FABRICATED PADEYE
XPE-20
1
A Steel Construction Fabricated Pad Eye / Anchor Point
N/A
3 tonnes
N/A
N/A
15/02/13
LOCATION: RISER DECK
SPECIFICATION: BS 2573 MPI METHOD: N/A PARTS EXAMINED: Entire body RESULTS: No defect as at the time of inspection. Fit for use TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A
Name and address of equipment owner : Pacific Drilling
Address of premises where test / Examination was held: Pacific Bora
We hereby certify that on 16/08/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection. Fit for use Signature of Inspector: Conducting Examination Name of Inspector: OLATUNJI AKINLADE Conducting: Examination only
Revision No: 01
Doc No: JCI-C-V-01
JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: service@jcinternationalng.com Website: www.jcinternationalng.com
CERTIFICATE OF VISUAL EXAMINATION
STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998
Certificate No. 7598 Identification Number Qty
Date of Examination 16/08/2012
Examiner OLATUNJI AKINLADE TARE WT SWL
Qualifications LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Description of Equipment
Examination
FABRICATED PADEYE
PL-LT-01
1
A Steel Construction Fabricated Pad Eye for Crane Load testing
N/A
50 tonnes
N/A
N/A
15/02/13
LOCATION: PIPE DECK
SPECIFICATION: BS 2573 MPI METHOD: N/A PARTS EXAMINED: Entire body RESULTS: No defect as at the time of inspection. Fit for use TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A
Name and address of equipment owner : Pacific Drilling
Address of premises where test / Examination was held: Pacific Bora
We hereby certify that on 16/08/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection. Fit for use Signature of Inspector: Conducting Examination Name of Inspector: OLATUNJI AKINLADE Conducting: Examination only
Revision No: 01
Doc No: JCI-C-V-01
JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: service@jcinternationalng.com Website: www.jcinternationalng.com
CERTIFICATE OF VISUAL EXAMINATION
STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998
Certificate No. 7599 Identification Number Qty
Date of Examination 16/08/2012
Examiner OLATUNJI AKINLADE TARE WT SWL
Qualifications LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Description of Equipment
Examination
FABRICATED PADEYE
PL-LT-02
1
A Steel Construction Fabricated Pad Eye for Crane Load testing
N/A
50 tonnes
N/A
N/A
15/02/13
LOCATION: PIPE DECK
SPECIFICATION: BS 2573 MPI METHOD: N/A PARTS EXAMINED: Entire body RESULTS: No defect as at the time of inspection. Fit for use TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A
Name and address of equipment owner : Pacific Drilling
Address of premises where test / Examination was held: Pacific Bora
We hereby certify that on 16/08/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection. Fit for use Signature of Inspector: Conducting Examination Name of Inspector: OLATUNJI AKINLADE Conducting: Examination only
Revision No: 01
Doc No: JCI-C-V-01
JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: service@jcinternationalng.com Website: www.jcinternationalng.com
CERTIFICATE OF VISUAL EXAMINATION AND MPI
STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998
Certificate No. 7600 Identification Number Qty
Date of Examination 16/08/2012
Examiner OLATUNJI AKINLADE TARE WT SWL
Qualifications LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Description of Equipment
Examination
FABRICATED PADEYE
PL-LT-03
1
A Steel Construction Fabricated Pad Eye for Crane Load testing
N/A
50 tonnes
N/A
N/A
15/02/13
LOCATION: RISER DECK
SPECIFICATION: BS 2573 MPI METHOD: Wet Visible PARTS EXAMINED: Entire body RESULTS: No defect as at the time of inspection. Fit for use TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-020 White Contrast Aid Black Magnetic Ink
Name and address of equipment owner : Pacific Drilling
Address of premises where test / Examination was held: Pacific Bora
We hereby certify that on 16/08/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection. Fit for use Signature of Inspector: Conducting Examination Name of Inspector: OLATUNJI AKINLADE Conducting: Examination only
Revision No: 01
Doc No: JCI-C-VMPI-01
JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: service@jcinternationalng.com Website: www.jcinternationalng.com
CERTIFICATE OF VISUAL EXAMINATION AND MPI
STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998
Certificate No. 7601 Identification Number Qty
Date of Examination 16/08/2012
Examiner OLATUNJI AKINLADE TARE WT SWL
Qualifications LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Description of Equipment
Examination
FABRICATED PADEYE
PL-LT-04
1
A Steel Construction Fabricated Pad Eye for Crane Load testing
N/A
50 tonnes
N/A
N/A
15/02/13
LOCATION: RISER DECK
SPECIFICATION: BS 2573 MPI METHOD: Wet Visible PARTS EXAMINED: Entire body RESULTS: No defect as at the time of inspection. Fit for use TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-020 White Contrast Aid Black Magnetic Ink
Name and address of equipment owner : Pacific Drilling
Address of premises where test / Examination was held: Pacific Bora
We hereby certify that on 16/08/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection. Fit for use Signature of Inspector: Conducting Examination Name of Inspector: OLATUNJI AKINLADE Conducting: Examination only
Revision No: 01
Doc No: JCI-C-VMPI-01
JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: service@jcinternationalng.com Website: www.jcinternationalng.com
CERTIFICATE OF VISUAL EXAMINATION
STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998
Certificate No. 7602 Identification Number Qty
Date of Examination 17/08/2012
Examiner OLATUNJI AKINLADE TARE WT SWL
Qualifications LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Description of Equipment
Examination
PADEYE
S-1
1
Ring Pad Eye
N/A
1 tonne
N/A
N/A
16/02/13
LOCATION: SACK STORE
SPECIFICATION: BS 2573 MPI METHOD: N/A PARTS EXAMINED: Entire body RESULTS: No defect as at the time of inspection. Fit for use TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A
Name and address of equipment owner : Pacific Drilling
Address of premises where test / Examination was held: Pacific Bora
We hereby certify that on 17/08/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection. Fit for use Signature of Inspector: Conducting Examination Name of Inspector: OLATUNJI AKINLADE Conducting: Examination only
Revision No: 01
Doc No: JCI-C-V-01
JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: service@jcinternationalng.com Website: www.jcinternationalng.com
CERTIFICATE OF VISUAL EXAMINATION
STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998
Certificate No. 7603 Identification Number Qty
Date of Examination 17/08/2012
Examiner OLATUNJI AKINLADE TARE WT SWL
Qualifications LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Description of Equipment
Examination
PADEYE
S-2
1
Ring Pad Eye
N/A
1 tonne
N/A
N/A
16/02/13
LOCATION: SACK STORE
SPECIFICATION: BS 2573 MPI METHOD: N/A PARTS EXAMINED: Entire body RESULTS: No defect as at the time of inspection. Fit for use TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A
Name and address of equipment owner : Pacific Drilling
Address of premises where test / Examination was held: Pacific Bora
We hereby certify that on 17/08/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection. Fit for use Signature of Inspector: Conducting Examination Name of Inspector: OLATUNJI AKINLADE Conducting: Examination only
Revision No: 01
Doc No: JCI-C-V-01
JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: service@jcinternationalng.com Website: www.jcinternationalng.com
CERTIFICATE OF VISUAL EXAMINATION
STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998
Certificate No. 7604 Identification Number Qty
Date of Examination 17/08/2012
Examiner OLATUNJI AKINLADE TARE WT SWL
Qualifications LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Description of Equipment
Examination
PADEYE
S-3
1
Ring Pad Eye
N/A
1 tonne
N/A
N/A
16/02/13
LOCATION: SACK STORE
SPECIFICATION: BS 2573 MPI METHOD: N/A PARTS EXAMINED: Entire body RESULTS: No defect as at the time of inspection. Fit for use TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A
Name and address of equipment owner : Pacific Drilling
Address of premises where test / Examination was held: Pacific Bora
We hereby certify that on 17/08/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection. Fit for use Signature of Inspector: Conducting Examination Name of Inspector: OLATUNJI AKINLADE Conducting: Examination only
Revision No: 01
Doc No: JCI-C-V-01
JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: service@jcinternationalng.com Website: www.jcinternationalng.com
CERTIFICATE OF VISUAL EXAMINATION
STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998
Certificate No. 7605 Identification Number Qty
Date of Examination 17/08/2012
Examiner OLATUNJI AKINLADE TARE WT SWL
Qualifications LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Description of Equipment
Examination
PADEYE
S-4
1
Ring Pad Eye
N/A
1 tonne
N/A
N/A
16/02/13
LOCATION: SACK STORE
SPECIFICATION: BS 2573 MPI METHOD: N/A PARTS EXAMINED: Entire body RESULTS: No defect as at the time of inspection. Fit for use TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A
Name and address of equipment owner : Pacific Drilling
Address of premises where test / Examination was held: Pacific Bora
We hereby certify that on 17/08/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection. Fit for use Signature of Inspector: Conducting Examination Name of Inspector: OLATUNJI AKINLADE Conducting: Examination only
Revision No: 01
Doc No: JCI-C-V-01
JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: service@jcinternationalng.com Website: www.jcinternationalng.com
CERTIFICATE OF VISUAL EXAMINATION
STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998
Certificate No. 7606 Identification Number Qty
Date of Examination 17/08/2012
Examiner OLATUNJI AKINLADE TARE WT SWL
Qualifications LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Description of Equipment
Examination
PADEYE
3D67802A
1
Pad Eye on Gripper Yoke
N/A
10 tonnes
N/A
N/A
16/02/13
LOCATION: PIPE DECK
SPECIFICATION: BS 2573 MPI METHOD: N/A PARTS EXAMINED: Entire body RESULTS: No defect as at the time of inspection. Fit for use TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A
Name and address of equipment owner: Pacific Drilling
Address of premises where test / Examination was held: Pacific Bora
We hereby certify that on 17/08/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection. Fit for use Signature of Inspector: Conducting Examination Name of Inspector: OLATUNJI AKINLADE Conducting: Examination only
Revision No: 01
Doc No: JCI-C-V-01
JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: service@jcinternationalng.com Website: www.jcinternationalng.com
CERTIFICATE OF VISUAL EXAMINATION
STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998
Certificate No. 7607 Identification Number Qty
Date of Examination 17/08/2012
Examiner OLATUNJI AKINLADE TARE WT SWL
Qualifications LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Description of Equipment
Examination
PADEYE
3D67802B
1
Pad Eye on Gripper Yoke
N/A
5 tonnes
N/A
N/A
16/02/13
LOCATION: PIPE DECK
SPECIFICATION: BS 2573 MPI METHOD: N/A PARTS EXAMINED: Entire body RESULTS: No defect as at the time of inspection. Fit for use TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A
Name and address of equipment owner : Pacific Drilling
Address of premises where test / Examination was held: Pacific Bora
We hereby certify that on 17/08/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection. Fit for use Signature of Inspector: Conducting Examination Name of Inspector: OLATUNJI AKINLADE Conducting: Examination only
Revision No: 01
Doc No: JCI-C-V-01
JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: service@jcinternationalng.com Website: www.jcinternationalng.com
CERTIFICATE OF VISUAL EXAMINATION
STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998
Certificate No. 7608 Identification Number Qty
Date of Examination 17/08/2012
Examiner OLATUNJI AKINLADE TARE WT SWL
Qualifications LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Description of Equipment
Examination
PADEYE
3D67802C
1
Pad Eye on Gripper Yoke
N/A
5 tonnes
N/A
N/A
16/02/13
LOCATION: PIPE DECK
SPECIFICATION: BS 2573 MPI METHOD: N/A PARTS EXAMINED: Entire body RESULTS: No defect as at the time of inspection. Fit for use TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A
Name and address of equipment owner : Pacific Drilling
Address of premises where test / Examination was held: Pacific Bora
We hereby certify that on 17/08/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection. Fit for use Signature of Inspector: Conducting Examination Name of Inspector: OLATUNJI AKINLADE Conducting: Examination only
Revision No: 01
Doc No: JCI-C-V-01
JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: service@jcinternationalng.com Website: www.jcinternationalng.com
CERTIFICATE OF VISUAL EXAMINATION
STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998
Certificate No. 7609 Identification Number Qty
Date of Examination 17/08/2012
Examiner OLATUNJI AKINLADE TARE WT SWL
Qualifications LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Description of Equipment
Examination
PADEYE
CWS-001
1
Pad Eye on Cat Walk
N/A
6 tonnes
N/A
N/A
16/02/13
LOCATION: CATWALK
SPECIFICATION: BS 2573 MPI METHOD: N/A PARTS EXAMINED: Entire body RESULTS: No defect as at the time of inspection. Fit for use TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A
Name and address of equipment owner : Pacific Drilling
Address of premises where test / Examination was held: Pacific Bora
We hereby certify that on 17/08/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection. Fit for use Signature of Inspector: Conducting Examination Name of Inspector: OLATUNJI AKINLADE Conducting: Examination only
Revision No: 01
Doc No: JCI-C-V-01
JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: service@jcinternationalng.com Website: www.jcinternationalng.com
CERTIFICATE OF VISUAL EXAMINATION
STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998
Certificate No. 7610 Identification Number Qty
Date of Examination 17/08/2012
Examiner OLATUNJI AKINLADE TARE WT SWL
Qualifications LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Description of Equipment
Examination
PADEYE
CWS-002
1
Pad Eye on Cat Walk
N/A
6 tonnes
N/A
N/A
16/02/13
LOCATION: CATWALK
SPECIFICATION: BS 2573 MPI METHOD: N/A PARTS EXAMINED: Entire body RESULTS: No defect as at the time of inspection. Fit for use TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A
Name and address of equipment owner : Pacific Drilling
Address of premises where test / Examination was held: Pacific Bora
We hereby certify that on 17/08/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection. Fit for use Signature of Inspector: Conducting Examination Name of Inspector: OLATUNJI AKINLADE Conducting: Examination only
Revision No: 01
Doc No: JCI-C-V-01
JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: service@jcinternationalng.com Website: www.jcinternationalng.com
CERTIFICATE OF VISUAL EXAMINATION
STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998
Certificate No. 7611 Identification Number Qty
Date of Examination 17/08/2012
Examiner OLATUNJI AKINLADE TARE WT SWL
Qualifications LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Description of Equipment
Examination
PADEYE
CWS-003
1
Pad Eye on Cat Walk
N/A
6 tonnes
N/A
N/A
16/02/13
LOCATION: CATWALK
SPECIFICATION: BS 2573 MPI METHOD: N/A PARTS EXAMINED: Entire body RESULTS: No defect as at the time of inspection. Fit for use TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A
Name and address of equipment owner : Pacific Drilling
Address of premises where test / Examination was held: Pacific Bora
We hereby certify that on 17/08/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection. Fit for use Signature of Inspector: Conducting Examination Name of Inspector: OLATUNJI AKINLADE Conducting: Examination only
Revision No: 01
Doc No: JCI-C-V-01
JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: service@jcinternationalng.com Website: www.jcinternationalng.com
CERTIFICATE OF VISUAL EXAMINATION
STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998
Certificate No. 7612 Identification Number Qty
Date of Examination 17/08/2012
Examiner OLATUNJI AKINLADE TARE WT SWL
Qualifications LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Description of Equipment
Examination
PADEYE
CWS-004
1
Pad Eye on Cat Walk
N/A
6 tonnes
N/A
N/A
16/02/13
LOCATION: CATWALK
SPECIFICATION: BS 2573 MPI METHOD: N/A PARTS EXAMINED: Entire body RESULTS: No defect as at the time of inspection. Fit for use TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A
Name and address of equipment owner : Pacific Drilling
Address of premises where test / Examination was held: Pacific Bora
We hereby certify that on 17/08/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection. Fit for use Signature of Inspector: Conducting Examination Name of Inspector: OLATUNJI AKINLADE Conducting: Examination only
Revision No: 01
Doc No: JCI-C-V-01
JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: service@jcinternationalng.com Website: www.jcinternationalng.com
CERTIFICATE OF VISUAL EXAMINATION
STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998
Certificate No. 7613 Identification Number Qty
Date of Examination 18/08/2012
Examiner OLATUNJI AKINLADE TARE WT SWL
Qualifications LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Description of Equipment
Examination
PADEYE
SP-085
1
Stanchion Pole Pad Eye
N/A
3 tonnes
N/A
N/A
17/02/13
LOCATION: RISER DECK
SPECIFICATION: BS 2573 MPI METHOD: N/A PARTS EXAMINED: Entire body RESULTS: No defect as at the time of inspection. Fit for use TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A
Name and address of equipment owner : Pacific Drilling
Address of premises where test / Examination was held: Pacific Bora
We hereby certify that on 18/08/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection. Fit for use Signature of Inspector: Conducting Examination Name of Inspector: OLATUNJI AKINLADE Conducting: Examination only
Revision No: 01
Doc No: JCI-C-V-01
JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: service@jcinternationalng.com Website: www.jcinternationalng.com
CERTIFICATE OF VISUAL EXAMINATION
STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998
Certificate No. 7614 Identification Number Qty
Date of Examination 18/08/2012
Examiner OLATUNJI AKINLADE TARE WT SWL
Qualifications LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Description of Equipment
Examination
PADEYE
SP-080
1
Stanchion Pole Pad Eye
N/A
3 tonnes
N/A
N/A
17/02/13
LOCATION: RISER DECK
SPECIFICATION: BS 2573 MPI METHOD: N/A PARTS EXAMINED: Entire body RESULTS: No defect as at the time of inspection. Fit for use TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A
Name and address of equipment owner: Pacific Drilling
Address of premises where test / Examination was held: Pacific Bora
We hereby certify that on 18/08/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection. Fit for use Signature of Inspector: Conducting Examination Name of Inspector: OLATUNJI AKINLADE Conducting: Examination only
Revision No: 01
Doc No: JCI-C-V-01
JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: service@jcinternationalng.com Website: www.jcinternationalng.com
CERTIFICATE OF VISUAL EXAMINATION
STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998
Certificate No. 7615 Identification Number Qty
Date of Examination 18/08/2012
Examiner OLATUNJI AKINLADE TARE WT SWL
Qualifications LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Description of Equipment
Examination
PADEYE
SP-107
1
Stanchion Pole Pad Eye
N/A
3 tonnes
N/A
N/A
17/02/13
LOCATION: RISER DECK
SPECIFICATION: BS 2573 MPI METHOD: N/A PARTS EXAMINED: Entire body RESULTS: No defect as at the time of inspection. Fit for use TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A
Name and address of equipment owner : Pacific Drilling
Address of premises where test / Examination was held: Pacific Bora
We hereby certify that on 18/08/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection. Fit for use Signature of Inspector: Conducting Examination Name of Inspector: OLATUNJI AKINLADE Conducting: Examination only
Revision No: 01
Doc No: JCI-C-V-01
JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: service@jcinternationalng.com Website: www.jcinternationalng.com
CERTIFICATE OF VISUAL EXAMINATION
STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998
Certificate No. 7616 Identification Number Qty
Date of Examination 18/08/2012
Examiner OLATUNJI AKINLADE TARE WT SWL
Qualifications LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Description of Equipment
Examination
PADEYE
SP-077
1
Stanchion Pole Pad Eye
N/A
3 tonnes
N/A
N/A
17/02/13
LOCATION: RISER DECK
SPECIFICATION: BS 2573 MPI METHOD: N/A PARTS EXAMINED: Entire body RESULTS: No defect as at the time of inspection. Fit for use TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A
Name and address of equipment owner : Pacific Drilling
Address of premises where test / Examination was held: Pacific Bora
We hereby certify that on 18/08/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection. Fit for use Signature of Inspector: Conducting Examination Name of Inspector: OLATUNJI AKINLADE Conducting: Examination only
Revision No: 01
Doc No: JCI-C-V-01
JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: service@jcinternationalng.com Website: www.jcinternationalng.com
CERTIFICATE OF VISUAL EXAMINATION
STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998
Certificate No. 7617 Identification Number Qty
Date of Examination 18/08/2012
Examiner OLATUNJI AKINLADE TARE WT SWL
Qualifications LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Description of Equipment
Examination
PADEYE
SP-089
1
Stanchion Pole Pad Eye
N/A
3 tonnes
N/A
N/A
17/02/13
LOCATION: RISER DECK
SPECIFICATION: BS 2573 MPI METHOD: N/A PARTS EXAMINED: Entire body RESULTS: No defect as at the time of inspection. Fit for use TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A
Name and address of equipment owner : Pacific Drilling
Address of premises where test / Examination was held: Pacific Bora
We hereby certify that on 18/08/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection. Fit for use Signature of Inspector: Conducting Examination Name of Inspector: OLATUNJI AKINLADE Conducting: Examination only
Revision No: 01
Doc No: JCI-C-V-01
JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: service@jcinternationalng.com Website: www.jcinternationalng.com
CERTIFICATE OF VISUAL EXAMINATION
STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998
Certificate No. 7618 Identification Number Qty
Date of Examination 18/08/2012
Examiner OLATUNJI AKINLADE TARE WT SWL
Qualifications LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Description of Equipment
Examination
PADEYE
SP-081
1
Stanchion Pole Pad Eye
N/A
3 tonnes
N/A
N/A
17/02/13
LOCATION: RISER DECK
SPECIFICATION: BS 2573 MPI METHOD: N/A PARTS EXAMINED: Entire body RESULTS: No defect as at the time of inspection. Fit for use TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A
Name and address of equipment owner : Pacific Drilling
Address of premises where test / Examination was held: Pacific Bora
We hereby certify that on 18/08/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection. Fit for use Signature of Inspector: Conducting Examination Name of Inspector: OLATUNJI AKINLADE Conducting: Examination only
Revision No: 01
Doc No: JCI-C-V-01
JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: service@jcinternationalng.com Website: www.jcinternationalng.com
CERTIFICATE OF VISUAL EXAMINATION
STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998
Certificate No. 7619 Identification Number Qty
Date of Examination 18/08/2012
Examiner OLATUNJI AKINLADE TARE WT SWL
Qualifications LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Description of Equipment
Examination
PADEYE
SP-100
1
Stanchion Pole Pad Eye
N/A
3 tonnes
N/A
N/A
17/02/13
LOCATION: RISER DECK
SPECIFICATION: BS 2573 MPI METHOD: N/A PARTS EXAMINED: Entire body RESULTS: No defect as at the time of inspection. Fit for use TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A
Name and address of equipment owner : Pacific Drilling
Address of premises where test / Examination was held: Pacific Bora
We hereby certify that on 18/08/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection. Fit for use Signature of Inspector: Conducting Examination Name of Inspector: OLATUNJI AKINLADE Conducting: Examination only
Revision No: 01
Doc No: JCI-C-V-01
JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: service@jcinternationalng.com Website: www.jcinternationalng.com
CERTIFICATE OF VISUAL EXAMINATION
STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998
Certificate No. 7620 Identification Number Qty
Date of Examination 18/08/2012
Examiner OLATUNJI AKINLADE TARE WT SWL
Qualifications LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Description of Equipment
Examination
PADEYE
SP-108
1
Stanchion Pole Pad Eye
N/A
3 tonnes
N/A
N/A
17/02/13
LOCATION: RISER DECK
SPECIFICATION: BS 2573 MPI METHOD: N/A PARTS EXAMINED: Entire body RESULTS: No defect as at the time of inspection. Fit for use TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A
Name and address of equipment owner : Pacific Drilling
Address of premises where test / Examination was held: Pacific Bora
We hereby certify that on 18/08/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection. Fit for use Signature of Inspector: Conducting Examination Name of Inspector: OLATUNJI AKINLADE Conducting: Examination only
Revision No: 01
Doc No: JCI-C-V-01
JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: service@jcinternationalng.com Website: www.jcinternationalng.com
CERTIFICATE OF VISUAL EXAMINATION
STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998
Certificate No. 7621 Identification Number Qty
Date of Examination 18/08/2012
Examiner OLATUNJI AKINLADE TARE WT SWL
Qualifications LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Description of Equipment
Examination
PADEYE
SP-092
1
Stanchion Pole Pad Eye
N/A
3 tonnes
N/A
N/A
17/02/13
LOCATION: RISER DECK
SPECIFICATION: BS 2573 MPI METHOD: N/A PARTS EXAMINED: Entire body RESULTS: No defect as at the time of inspection. Fit for use TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A
Name and address of equipment owner : Pacific Drilling
Address of premises where test / Examination was held: Pacific Bora
We hereby certify that on 18/08/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection. Fit for use Signature of Inspector: Conducting Examination Name of Inspector: OLATUNJI AKINLADE Conducting: Examination only
Revision No: 01
Doc No: JCI-C-V-01
JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: service@jcinternationalng.com Website: www.jcinternationalng.com
CERTIFICATE OF VISUAL EXAMINATION
STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998
Certificate No. 7622 Identification Number Qty
Date of Examination 18/08/2012
Examiner OLATUNJI AKINLADE TARE WT SWL
Qualifications LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Description of Equipment
Examination
PADEYE
SP-084
1
Stanchion Pole Pad Eye
N/A
3 tonnes
N/A
N/A
17/02/13
LOCATION: RISER DECK
SPECIFICATION: BS 2573 MPI METHOD: N/A PARTS EXAMINED: Entire body RESULTS: No defect as at the time of inspection. Fit for use TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A
Name and address of equipment owner: Pacific Drilling
Address of premises where test / Examination was held: Pacific Bora
We hereby certify that on 18/08/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection. Fit for use Signature of Inspector: Conducting Examination Name of Inspector: OLATUNJI AKINLADE Conducting: Examination only
Revision No: 01
Doc No: JCI-C-V-01
JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: service@jcinternationalng.com Website: www.jcinternationalng.com
CERTIFICATE OF VISUAL EXAMINATION
STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998
Certificate No. 7623 Identification Number Qty
Date of Examination 18/08/2012
Examiner OLATUNJI AKINLADE TARE WT SWL
Qualifications LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Description of Equipment
Examination
PADEYE
SP-088
1
Stanchion Pole Pad Eye
N/A
3 tonnes
N/A
N/A
17/02/13
LOCATION: RISER DECK
SPECIFICATION: BS 2573 MPI METHOD: N/A PARTS EXAMINED: Entire body RESULTS: No defect as at the time of inspection. Fit for use TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A
Name and address of equipment owner : Pacific Drilling
Address of premises where test / Examination was held: Pacific Bora
We hereby certify that on 18/08/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection. Fit for use Signature of Inspector: Conducting Examination Name of Inspector: OLATUNJI AKINLADE Conducting: Examination only
Revision No: 01
Doc No: JCI-C-V-01
JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: service@jcinternationalng.com Website: www.jcinternationalng.com
CERTIFICATE OF VISUAL EXAMINATION
STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998
Certificate No. 7624 Identification Number Qty
Date of Examination 18/08/2012
Examiner OLATUNJI AKINLADE TARE WT SWL
Qualifications LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Description of Equipment
Examination
PADEYE
SP-098
1
Stanchion Pole Pad Eye
N/A
3 tonnes
N/A
N/A
17/02/13
LOCATION: RISER DECK
SPECIFICATION: BS 2573 MPI METHOD: N/A PARTS EXAMINED: Entire body RESULTS: No defect as at the time of inspection. Fit for use TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A
Name and address of equipment owner : Pacific Drilling
Address of premises where test / Examination was held: Pacific Bora
We hereby certify that on 18/08/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection. Fit for use Signature of Inspector: Conducting Examination Name of Inspector: OLATUNJI AKINLADE Conducting: Examination only
Revision No: 01
Doc No: JCI-C-V-01
JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: service@jcinternationalng.com Website: www.jcinternationalng.com
CERTIFICATE OF VISUAL EXAMINATION
STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998
Certificate No. 7625 Identification Number Qty
Date of Examination 18/08/2012
Examiner OLATUNJI AKINLADE TARE WT SWL
Qualifications LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Description of Equipment
Examination
PADEYE
SP-104
1
Stanchion Pole Pad Eye
N/A
3 tonnes
N/A
N/A
17/02/13
LOCATION: RISER DECK
SPECIFICATION: BS 2573 MPI METHOD: N/A PARTS EXAMINED: Entire body RESULTS: No defect as at the time of inspection. Fit for use TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A
Name and address of equipment owner : Pacific Drilling
Address of premises where test / Examination was held: Pacific Bora
We hereby certify that on 18/08/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection. Fit for use Signature of Inspector: Conducting Examination Name of Inspector: OLATUNJI AKINLADE Conducting: Examination only
Revision No: 01
Doc No: JCI-C-V-01
JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: service@jcinternationalng.com Website: www.jcinternationalng.com
CERTIFICATE OF VISUAL EXAMINATION
STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998
Certificate No. 7626 Identification Number Qty
Date of Examination 18/08/2012
Examiner OLATUNJI AKINLADE TARE WT SWL
Qualifications LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Description of Equipment
Examination
PADEYE
SP-199
1
Stanchion Pole Pad Eye
N/A
3 tonnes
N/A
N/A
17/02/13
LOCATION: RISER DECK
SPECIFICATION: BS 2573 MPI METHOD: N/A PARTS EXAMINED: Entire body RESULTS: No defect as at the time of inspection. Fit for use TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A
Name and address of equipment owner : Pacific Drilling
Address of premises where test / Examination was held: Pacific Bora
We hereby certify that on 18/08/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection. Fit for use Signature of Inspector: Conducting Examination Name of Inspector: OLATUNJI AKINLADE Conducting: Examination only
Revision No: 01
Doc No: JCI-C-V-01
JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: service@jcinternationalng.com Website: www.jcinternationalng.com
CERTIFICATE OF VISUAL EXAMINATION
STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998
Certificate No. 7627 Identification Number Qty
Date of Examination 18/08/2012
Examiner OLATUNJI AKINLADE TARE WT SWL
Qualifications LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Description of Equipment
Examination
PADEYE
SP-101
1
Stanchion Pole Pad Eye
N/A
3 tonnes
N/A
N/A
17/02/13
LOCATION: RISER DECK
SPECIFICATION: BS 2573 MPI METHOD: N/A PARTS EXAMINED: Entire body RESULTS: No defect as at the time of inspection. Fit for use TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A
Name and address of equipment owner : Pacific Drilling
Address of premises where test / Examination was held: Pacific Bora
We hereby certify that on 18/08/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection. Fit for use Signature of Inspector: Conducting Examination Name of Inspector: OLATUNJI AKINLADE Conducting: Examination only
Revision No: 01
Doc No: JCI-C-V-01
JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: service@jcinternationalng.com Website: www.jcinternationalng.com
CERTIFICATE OF VISUAL EXAMINATION
STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998
Certificate No. 7628 Identification Number Qty
Date of Examination 18/08/2012
Examiner OLATUNJI AKINLADE TARE WT SWL
Qualifications LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Description of Equipment
Examination
PADEYE
SP-095
1
Stanchion Pole Pad Eye
N/A
3 tonnes
N/A
N/A
17/02/13
LOCATION: RISER DECK
SPECIFICATION: BS 2573 MPI METHOD: N/A PARTS EXAMINED: Entire body RESULTS: No defect as at the time of inspection. Fit for use TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A
Name and address of equipment owner : Pacific Drilling
Address of premises where test / Examination was held: Pacific Bora
We hereby certify that on 18/08/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection. Fit for use Signature of Inspector: Conducting Examination Name of Inspector: OLATUNJI AKINLADE Conducting: Examination only
Revision No: 01
Doc No: JCI-C-V-01
JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: service@jcinternationalng.com Website: www.jcinternationalng.com
CERTIFICATE OF VISUAL EXAMINATION
STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998
Certificate No. 7629 Identification Number Qty
Date of Examination 18/08/2012
Examiner OLATUNJI AKINLADE TARE WT SWL
Qualifications LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Description of Equipment
Examination
PADEYE
SP-094
1
Stanchion Pole Pad Eye
N/A
3 tonnes
N/A
N/A
17/02/13
LOCATION: RISER DECK
SPECIFICATION: BS 2573 MPI METHOD: N/A PARTS EXAMINED: Entire body RESULTS: No defect as at the time of inspection. Fit for use TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A
Name and address of equipment owner : Pacific Drilling
Address of premises where test / Examination was held: Pacific Bora
We hereby certify that on 18/08/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection. Fit for use Signature of Inspector: Conducting Examination Name of Inspector: OLATUNJI AKINLADE Conducting: Examination only
Revision No: 01
Doc No: JCI-C-V-01
JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: service@jcinternationalng.com Website: www.jcinternationalng.com
CERTIFICATE OF VISUAL EXAMINATION
STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998
Certificate No. 7630 Identification Number Qty
Date of Examination 18/08/2012
Examiner OLATUNJI AKINLADE TARE WT SWL
Qualifications LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Description of Equipment
Examination
PADEYE
SP-093
1
Stanchion Pole Pad Eye
N/A
3 tonnes
N/A
N/A
17/02/13
LOCATION: RISER DECK
SPECIFICATION: BS 2573 MPI METHOD: N/A PARTS EXAMINED: Entire body RESULTS: No defect as at the time of inspection. Fit for use TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A
Name and address of equipment owner: Pacific Drilling
Address of premises where test / Examination was held: Pacific Bora
We hereby certify that on 18/08/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection. Fit for use Signature of Inspector: Conducting Examination Name of Inspector: OLATUNJI AKINLADE Conducting: Examination only
Revision No: 01
Doc No: JCI-C-V-01
JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: service@jcinternationalng.com Website: www.jcinternationalng.com
CERTIFICATE OF VISUAL EXAMINATION
STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998
Certificate No. 7631 Identification Number Qty
Date of Examination 18/08/2012
Examiner OLATUNJI AKINLADE TARE WT SWL
Qualifications LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Description of Equipment
Examination
PADEYE
SP-102
1
Stanchion Pole Pad Eye
N/A
3 tonnes
N/A
N/A
17/02/13
LOCATION: RISER DECK
SPECIFICATION: BS 2573 MPI METHOD: N/A PARTS EXAMINED: Entire body RESULTS: No defect as at the time of inspection. Fit for use TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A
Name and address of equipment owner : Pacific Drilling
Address of premises where test / Examination was held: Pacific Bora
We hereby certify that on 18/08/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection. Fit for use Signature of Inspector: Conducting Examination Name of Inspector: OLATUNJI AKINLADE Conducting: Examination only
Revision No: 01
Doc No: JCI-C-V-01
JC International Limited
RC. 413243
Port Harcourt Office: Plot 5 JC Street, Off Peter Odili Road, P.O. Box 6427 Trans Amadi Port Harcourt, Rivers State. Tel: +234-84-489909 Lagos Office: 56A Bourdillon Road, P.O. Box 52224 Ikoyi. Tel: +234-1-842-5813 E-mail: service@jcinternationalng.com Website: www.jcinternationalng.com
CERTIFICATE OF VISUAL EXAMINATION
STATUTORY INSTRUMENTS 1998 NO. 2307 The Lifting Operations and Lifting Equipment Regulations 1998 STATUTORY INSTRUMENTS 1992 NO. 3073 The Supply of Machinery (Safety) Regulations 1992 STATUTORY INSTRUMENTS 1998 NO. 2306 The Provision and use of Work Equipment Regulations 1998
Certificate No. 7632 Identification Number Qty
Date of Examination 19/08/2012
Examiner OLATUNJI AKINLADE TARE WT SWL
Qualifications LEEA, SNT LEVEL II MT, PT & UT GROSS WT Proof Load Applied Date of next
Description of Equipment
Examination
FABRICATED PADEYE
BTR-001
1
A Steel Construction Fabricated Pad Eye / Anchor Point
N/A
3 tonnes
N/A
N/A
18/02/13
LOCATION: UPPER DECK
SPECIFICATION: BS 2573 MPI METHOD: N/A PARTS EXAMINED: Entire body RESULTS: No defect as at the time of inspection. Fit for use TEST PROCEDURE: CONTRAST MEDIA: INDICATOR: JOP-010 N/A N/A
Name and address of equipment owner : Pacific Drilling
Address of premises where test / Examination was held: Pacific Bora
We hereby certify that on 19/08/2012 (date) no defect was found on the item/s described on this Certificate as at the time of inspection. Fit for use Signature of Inspector: Conducting Examination Name of Inspector: OLATUNJI AKINLADE Conducting: Examination only
Revision No: 01
Doc No: JCI-C-V-01