ZVS
ZVS
Introduction
Advances in resonant and quasi-resonant power conversion technology propose alternative solutions to a conflicting set of square wave conversion design goals; obtaining high efficiency operation at a high switching frequency from a high voltage source. Currently, the conventional approaches are by far, still in the production mainstream. However, an increasing challenge can be witnessed by the emerging resonant technologies, primarily due to their lossless switching merits. The intent of this presentation is to unravel the details of zero voltage switching via a comprehensive analysis of the timing intervals and relevant voltage and current waveforms. The concept of quasi-resonant, lossless switching is not new, most noticeably patented by one individual [1] and publicized by another at various power conferences [2,3]. Numerous efforts focusing on zero current switching ensued, first perceived as the likely candidate for tomorrows generation of high frequency power converters [4,5,6,7,8]. In theory, the onoff transitions occur at a time in the resonant cycle where the switch current is zero, facilitat3-329
APPLICATION NOTE
U-138
Fig. 1 - Zero Voltage Switching vs. Conventional Square Wave unlike the energy transfer system of its electrical dual, the zero current switched converter. During the ZVS switch off-time, the L-C tank circuit resonates. This traverses the voltage across the switch from zero to its peak, and back down again to zero. At this point the switch can be reactivated, and lossless zero voltage switching facilitated. Since the output capacitance of the MOSFET switch (Co& has been discharged by the resonant tank, it does not contribute to power loss or dissipation in the switch. Therefore, the MOSFET transition losses go to zero - regardless of operating frequency and input voltage. This could represent a significant savings in power, and result in a substantial improvement in efficiency. Obviously, this attribute makes zero voltage switching a suitable candidate for high frequency, high voltage converter designs. Additionally, the gate drive requirements are somewhat reduced in a ZVS design due to the lack of the gate to drain (Miller) charge, which is deleted when V& equals zero. The technique of zero voltage switching is applicable to all switching topologies; the buck regulator and its derivatives (forward, half and full bridge), the flyback, and boost converters, to name a few. This presentation will focus on the continuous output current, buck derived topologies, however a list of references describing the others has been included in the appendix.
Zero power Lossless switching transitions Reduced EMI / RFI at transitions No power loss due to discharging Goss No higher peak currents, (ie. ZCS) same as square wave systems High efficiency with high voltage inputs at any frequency Can incorporate parasitic circuit and component L & C
3-330
APPLICATION NOTE
n
U-138
filter section consisting of output inductor L.,,, and capacitor CO has a time constant several orders of magnitude larger than any power conversion period. The filter inductance is large in comparison to that of the resonant inductors value L, and the magnetizing current ML., as well as the inductors DC resistance is negligible. In addition, both the input voltage VjN and output voltage V. are purely DC, and do not vary during a given conversion cycle. Last, the converter is operating in a closed loop configuration which regulates the output voltage V. .
Variable frequency operation (in general) Higher off-state voltages in single switch, unclamped topologies Relatively new technology - users must climb the learning curve Conversion frequency is inversely proportional to load current A more sophisticated control circuit may be required
to
t,
The conversion period is initiated at time t, when switch Q, is turned OFF. Since the current through resonant inductor L, and output inductor L, cannot change instantaneously, and no drain current flows in Q, while
APPLICATION NOTE
U-138
Table II - CAPACITOR CHARGING: b - tl
Resonant State: t, - t,
The resonant portion of the conversion cycle begins at tI when the voltage across resonant capacitor VCR equals the input voltage VIN, and the output catch diode begins conducting. At t, , current through the resonant components IcR and ILR equals the output current I,. The stimulus for this series resonant L-C circuit is output current I, flowing through the resonant inductor prior to time t,. The ensuing resonant tank current follows a cosine function beginning at time t,, and ending at time t2. At the natural resonant frequency OR9 each of the L-C tank components exhibit an impedance equal to the tank impedance, ZR. Therefore, the peak voltage across CR and switch Q, are a function of ZR and I, . The instantaneous voltage across CR and Q, can be evaluated over the resonant time interval using the following relationships:
it is off, the current is diverted around the switch through the resonant capacitor CR. The constant output current will linearly increase the voltage across the resonant capacitor until it reaches the input voltage (VCR = VI,,,). Since the current is not changing, neither is the voltage across resonant inductor L,. At time t, the switch current IO instantly drops from IO to zero. Simultaneously, the resonant capacitor current IcR snaps from zero to I,, while the resonant inductor current ILR and output inductor current IL0 are constant and also equal to I, during interval toI. Voltage across output inductor Lo and output catch diode D, linearly decreases during this interval due to the linearly increasing voltage across resonant capacitor CR. At time tl , VCR equals and D, starts to conduct.
3-332
Of greater importance is the ability to solve the equations for the precise off-time of the switch. This off-time will vary with line and load changes and the control circuit must respond in order to facilitate true zero voltage switching. While some allowance does exist for a fixed off time technique, the degree of lati-
APPLICATION NOTE tude is insufficient to accommodate typical input and output variations, The exact time is obtained by solving the resonant capacitor voltage equations for the condition when zero voltage is attained. VCR (t)ve
LINE
U-138
CHANGES
The equation can be further simplified by extracting the half cycle (180 degrees) of conduction which is a constant for a given resonant frequency, and equal to ~rr/t+.
The resonant component current (IcR = IL.) is a cosine function between time tl and tz, described as: The absolute maximum duration for this interval occurs when 270 degrees (3x/2& of resonant operation is required to intersect the zero voltage axis. This corresponds to the limit of resonance as minimum load and maximum line voltage are approached. Contributions of line and load influences on the resonant time interval t12 can be analyzed individually as shown in Figs. 7 and 8. Prior to time tl, the catch diode Do was not conducting. Its voltage, VW, was linearly decreasing from V,N at time to to zero at tl while input source v,Jv was supplying full output current, IO. At time t,, however, this situation changes as the resonant capacitor initiates resonance, diverting the resonant inductor current away from the output filter section. Instantly, the output diode voltage, Vm, changes polarity as it begins to conduct, supplementing the decreasing resonant inductor current with diode current I, extracted from stored energy in output inductor Lo. The diode current waveshape follows a cosine function during this interval, equalling IO minus IcR(t)# Also occurring at time t,, the output filter inductor Lo releases the stored energy required
3-333
Fig. 8 -- Resonant Capacitor Voltage vs. Load to maintain a constant output current I,. Its
reverse voltage is clamped to the output voltage V. minus the diode voltage drop V by the convention followed by Figure 4.
Table III - RESONANT INTERVAL: tl - b
APPLICATION NOTE
the conversion period, most of the pertinent waveforms approach DC conditions. Assuming ideal components, with Q, closed, the input source supplies output current , and the output filter inductor voltage VLo equals VIN - Vo. The switch current and resonant inductor current are both equal to IO, and their respective voltage drops are zero (V& = V,=O). Catch diode voltage Vm equals VIN, and Im = 0. In closed loop operation where the output voltage is in regulation, the control circuit essentially varies the on-time of the switch during the tJ4 interval. Variable frequency operation is actually the result of modulating the on-time as dictated by line and load conditions. Increasing the time duration, or lowering the conversion frequency has the same effect as widening the duty cycle in a traditional square wave converter. For example, if the output voltage were to drop in response to an increased load, the conversion frequency would decrease in order to raise the effective ON period. Conversely, at light loads where little energy is drawn from the output capacitor, the control circuit would adjust to minimize the lJ, duration by increasing the conversion frequency. In summary, the conversion frequency is inversely proportional to the power delivered to the load.
Once the resonant inductor current ILR has reached I, at time tJ, the zero voltage switched converter resembles a conventional square wave power processor. During the remainder of
3-334
t3
- tr
APPLICATION NOTE
Table V - POWER TRANSFER: t3 - t,
COMP. STATUS CIRCUIT VALUES
U-138
APPLICATION NOTE
U-138
Both the minimum on-time and maximum off-time have been described in terms of the resonant tank frequency , wR. Taking this one step further will result in the maximum conversion frequency fCoti, also as a function of the resonant tank frequency.
Maximum Off-Time:
The maximum conversion frequency corresponds to the minimum conversion period, TcoW,, , which is the sum of the minimum ontime and maximum off-time:
The ratio of the maximum conversion frequency to that of the resonant tank frequency can be expressed as a topology coefficient, Kr. For this zero voltage switched Buck regulator and its derivatives, KTmax equals:
3-336
APPLICATION NOTE
U-138
conversion period where tJ4 equals zero. Topology coefficient K-r will be incorporated to define the ratio of the maximum conversion frequency (minimum conversion period) to that of the resonant tank frequency, OR.
In a realistic application, the output voltage of the power supply is held in regulation at VO which stipulates that the on-time in the power processing state, tJ4 , cannot go to zero as in the example above. The volt-second product requirements of the output must be satisfied during this period, just as in any square wave converter design. Analogous to minimum duty cycle, the minimum on-time for a given design will be a function of V&, VO and the resonant tank frequency, oR. Although small, a specific amount of energy is transferred from the input to the output during the capacitor charging interval t,. The voltage into the output filter section linearly decreases from & at time t, to zero at tl, equal to an average value of V,,,,/2. In addition, a constant current equal to the output current I, was being supplied from the input source. The average energy transferred during this interval is defined as:
This demonstrates that a zero power output is unobtainable in reality. The same is true for the ability to obtain zero output voltage. The equation can be rewritten as:
Solving for the highest minimum output voltage, the worst case for occurs when I, equals Iomin and VIN is at its maximum, VlN-.
Under normal circumstances the circuit will be operating far above this minimum requirement. In most applications, the amount of power transferred during the capacitor charging interval t, can be neglected as it represents less than seven percent (7%) of the minimum input power. This corresponds to less than one percent of the total input power assuming a 10:1 load range.
This minimum energy can be equated to minimum output watts by dividing it by its
3-337
APPLICATION NOTE
resonant and output inductors to maintain the minimum output current, Iolrdn. In summary, NO output power is derived from VN during interval tm. The power required to support V0 at its current of I0 is obtained from the input source during the power transfer period tJ4. Therefore, an effective duty cycle can be used to describe the power transfer interval fJ4 to that of the entire switching period, tw, or Tconrv.
ZVS - Effective Duty Cycle Calculations:
U-138
could optionally be evaluated. A computer program to calculate the numerous time intervals and conversion frequencies as a function of line and load can simplify the design process, if not prove to be indispensable. Listed in the Appendix of this section is a BASIC language program which can be used to initiate the design procedure. To summarize: When the switch is on, replace v;N with KWv&(On)) = RDS(on))* When the free-wheeling diode is on, replace V. with (Vo+VF).
(I/IN-IO l
And can be analyzed over line and load ranges using previous equations for each interval.
3-338
APPLICATION NOTE
N=
Primary Turns Secondary Turns
U-138
Determining Transformer Turns Ratio (N): The transformer turns ratio is derived from the equations used to define the power transfer interval tM in addition to the maximum offtime, tcu. While this may first seem like an iterative process, it simplifies to the volt-second product relationship described. The general
equations are listed below. The turns ratio N is derived by substituting The resonant tank component equations now become:
I
Note: the calculated resonant inductance value does not include any series inductance, typical of the transformer leakage and wiring inductances.
The transformer magnetizing and leakage inductance is part of the resonant inductance. This requires adjustment of the resonant inductor value, or both the resonant tank impedance zR and frequency wR will be off-target. One
Note: the calculated resonant capacitor value does not include any parallel capacitance, typical of a MOSFET output capacitance, Goss, in shunt. Multi-transistor variations of the buck topology should accommodate all switch capacitances in the analysis. Timing Equations (including N):
option is to design the transformer inductance to be exactly the required resonant inductance, thus eliminating one component. For precision applications, the transformer inductance should be made slightly smaller than required, and shimmed up with a small inductor.
3-339
APPLICATION NOTE
3-340
APPLICATION NOTE
ZVS Clamped Configurations -- Half and Full Bridge Topologies: Zero voltage switching can be extended to multiple switch topologies for higher power levels, specifically the half and full bridge configurations. While the basic operation of each time interval remains similar, there is a difference in the resonant tlZ interval. While single switch converters have high offstate voltage, the bridge circuits clamp the switch peak voltages to the DC input rails, reducing the switch voltage stress. This alters the duration of the off segment of the resonant interval, since the opposite switch(es) must be activated long before the resonant cycle is completed. In fact, the opposite switch(es) should be turned on immediately after their voltage is clamped to the rails, where their drain to source voltage equals zero. If not, the resonant tank will continue to ring and return the switch voltage to its starting point, the opposite rail. Additionally, this off period varies with line and load changes. Examples of this are demonstrated in Figs. 14 and 15. To guarantee true zero voltage switching, it is recommended that the necessary sense circuitry be incorporated.
U-138
3-341
APPLICATION NOTE
ZVS Half Bridge: The same turns ratio, N, relationship applies to the half bridge topology when & in the previous equations is considered to be one-half of the bulk rail-torail voltage. V& is the voltage across the transformer primary when either switch is on. Refer to the circuit and waveforms of Figs. 14 and 15. CR, the resonant capacitor becomes the parallel combination of the two resonant capacitors, the ones across each switch. Although the resonant inductor value is unaffected, all series leakage and wiring inductance must be taken into account.
The off state voltages of the switches will try to exceed the input bulk voltage during the resonant stages. Automatic
U-138
clamping to the input bulk rails occurs by the MOSFET body diode, which can be externally shunted with a higher performance variety. Unlike the forward converter which requires a core reset equal to the applied volt second product, the bidirectional switching of the half (and full) bridge topology facilitate automatic core reset during consecutive switching cycles [ll,l2].
APPLICATION NOTE
ZVS Full Bridge: The equations represented for the forward topology apply equally well for one conversion cycle of the full bridge topology, including the transformer turns ratio. Since the resonant capacitors located at each switch are in-circuit at all times, the values should be adjusted accordingly. As with the half bridge converter, the resonant capacitors voltage will exceed the bulk rails, and clamping via the FET body diodes or external diodes to the rails is common [13].
U-138
APPLICATION NOTE
U-138
8. Breadboard the circuit carefully using RF techniques wherever possible. Remember -parasitic inductances and capacitances prefer to resonate upon stimulation, and quite often, unfavorably. 9. Debug and modify the circuit as required to accommodate component parasitics, layout concerns or packaging considerations.
Avoiding Parasitics
Ringing of the catch diode junction capacitance with circuit inductance (and package leads) will significantly degrade the circuit performance. Probably the most common solution to this everyday occurrance in square wave converters is to shunt the diode with an R-C snubber. Although somewhat dissipative, a compromise can be established between snubber losses and parasitic overshoot caused by the ringing. Unsnubbed examples of various applicable diodes are shown in Fig. 20 below.
Note: Increase IO,,,,.,, if Vs= is too high if possible). For clamped VDSnw = bvnuu applications (bridges):
3. Select a resonant tank frequency, OR (HINT: OR = 2x&). 4. Calculate the resonant tank impedance and component values. 5. Calculate each of the interval durations (toI thru fM) and their ranges as a function of all line and load combinations. (See Appendix for a sample computer program written in BASIC) Additionally, summarize the results to establish the range of conversion frequencies, peak voltages and currents, etc. 6. Analyze the results. Determine if the frequency range is suitable for the application. If not, a recommendation is to limit the load range by raising rod,, and start the design procedure again. Verify also that the design is feasible with existing technology and components. 7. Finalize the circuit specifics and details. 0 Derive the transformer turns ratio. (nonbuck applications) 0 Design the output filter section based upon the lowest conversion frequency and output ripple current&( 0 Select applicable components; diode, MOSFET etc.
3-344
APPLICATION NOTE
U-138
determined by the UC3843A output pulse width. Zero voltage switching is performed by the UC3864 one-shot timer and zero crossing detection circuitry. When the resonant capacitor voltage crosses zero, the UC3864 output goes high. This turns ON the power switch and recycles the UC3843A to initiate the next current mode controlled period. The UC3864 fault circuitry functions, but its error amplifier and VCO are not used.
APPLICATION NOTE
U-138
Table VI - Interval Durations vs. Line & Load
mise between high frequency operation and low parasitic effects of the components and layout.
5. Calculate each of the interval durations @,, thru f& and ranges as they vary with line and load changes.
The zero voltage switched buck converter gain in kiloHertz per volt of V,N and kHz
It may be necessary to use the highest gain values to design the control loop compensation for stability over all operating conditions. While this may not optimize the loop transient response for all operating loads, it will guarantee stability over the extremes of line and load.
3-346
APPLICATION NOTE
U-138
A. Output Filter Section: Select L, and CO
for operation at the lowest conversion frequency and designed ripple current. B. Heatsink Requirements: An estimate of the worst case power dissipation of the power switch and output catch diode can be made over line and load ranges.
C. Control Circuit: The UC3861-64 series of
APPLICATION NOTE
U-138
lated range of conversion frequencies spans 87 to 310 kHz. These values will be used for this first cut draft of the control circuit programming. Due to the numerous circuit specifics omitted from the computer program for simplicity, the actual range of conversion frequencies will probably be somewhat wider than planned. Later, the actual timing component values can be adjusted to accommodate these differences. First, a minimum fc o f 7 5 k H z h a s b e e n selected and programmed according to the following equation:
Fig. 26 -- CR Volts & Off-time vs. Line & Load time. Initially, the one-shot is programmed for the maximum off-time, and modulated via the ZERO detection circuitry. The switch drainsource voltage is sensed and scaled to initiate turn-on when the precision 0.5V threshold is crossed. This offset was selected to accommodate propogation delays between the instant the threshold is sensed and the instant that the switch is actually turned on. Although brief, these delays can become significant in high frequency applications, and if left unaccounted, can cause NONZERO switching transitions. Referring to Fig. 26, in this design, the offtime varies between 1.11 and 1.80 microseconds, using ideal components and neglecting temperature effects on the resonant components. Since the ZERO detect logic will facilitate true zero voltage switching, the off-time can be set for a much greater period. The one-shot has a 3:1 range capability and will be programmed for 2.2 U S ( m a x ) , c o n t r o l l a b l e d o w n t o 0 . 7 5 U S. Programming of the one-shot requires a single R-C time constant, and is straightforward using the design information and equations from the data sheet. Implementation of this feature is shown in the control circuit schematic. Programming the VCO. The calcu-
Numerous values of Rti,, and C,, will satisfy the equations. The procedure can be simplified by letting Rtin equal 100K.
The VCO gain in frequency per volt from the error amplifier output is approximated by:
APPLICATION NOTE
Fault Protection - Soft Start & Restart Delay One of the unique features of the UC 3861 family of resonant mode controllers can be found in its fault management circuitry. A single pin connection interfaces with the soft start, restart delay and programmable fault mode protection circuits. In most applications, one capacitor to ground will provide full protection upon power-up and during overload conditions. Users can reprogram the timing relationships or add control features (latch off following fault, etc) with a single resistor. Selected for this application is a 1 uF softrestart capacitor value, resulting in a soft-start duration of 10 ms and a restart delay of approximately 200 ms. The preprogrammed ratio of 19:l (restart delay to soft start) will be utilized, however the relevant equations and relationships have also been provided for other applications. Primary current will be utilized as the fault trip mechanism, indicative of an overload or short circuit current condition. A current transformer is incorporated to maximize efficiency when interfacing to the three volt fault threshold. Optional Programming of Tss and Tm : Soft Start: Tss = CSR. 10K Restart Delay: Tm = CsR. 1 9 O K Timing Ratio: Tm:Tss = 1 9 : l Gate Drive: Another unique feature of the UC 3861-64 family of devices is the optimal utilization of the silicon devoted to output totem pole drivers. Each controller uses two pins for the A and B outputs which are internally configured to operate in either unison or in an alternating configuration. Typical performance for these 1 Amp peak totem pole outputs shows 30 ns rise and fall times into 1 n F . Loop Compensation -- General Information. The ZVS technique is similar to that of conventional voltage mode square wave conversion which utilizes a single voltage feedback loop. Unlike the dual loop system of current mode control, the ZVS output filter section exhibits
U-138
Fig. 29 -- Fault Operational Waveforms a two pole-zero pair and is compensated accordingly. Generally, the overall loop is designed to cross zero dB at a frequency below one-tenth that of the switching frequency. In this variable frequency converter, the lowest conversion frequency will apply, corresponding to approximately 85 KHz, for a zero crossing of 8.5 KHz. Compensation should be optimized for the highest low frequency gain in addition to ample phase margin at crossover. Typical examples utilize two zeros in the error amplifier compensation at a frequency equal to that of the output filters two pole break. An additional high frequency pole is placed in the loop to combat the zero due to the output capacitance ESR, assuming adequate error amplifier gainbandwidth. A noteworthy alternative is the use of a two loop approach which is similar to current mode control, eliminating one of the output poles. One technique known as Multi-Loop Control for Quasi-Resonant Converters [18] has been
3-349
APPLICATION NOTE
developed. Another, called Average Current Mode Control is also a suitable candidate,
U-138
Summary The zero voltage switched quasi-resonant technique is applicable to most power conversion designs, but is most advantageous to those operating from a high voltage input. In these applications, losses associated with discharging of the MOSFET output capacitance can be significant at high switching frequencies, impairing efficiency. Zero voltage switching avoids this penalty by negating the drain-to-source, off-state voltage via the resonant tank. A high peak voltage stress occurs across the switch during resonance in the buck regulator and single switch forward converters. Limiting this excursion demands limiting the useful load range of the converter as well, an unacceptable solution in certain applications. For these situations, the zero voltage switched multiresonant approach [14,15] could prove more beneficial than the quasi-resonant ZVS variety. Significant improvements in efficiency can be obtained in high voltage, half and full bridge ZVS applications when compared to their square wave design complements. Clamping of
APPLICATION NOTE
the peak resonant voltage to the input rails avoids the high voltage overshoot concerns of the single switch converters, while transformer reset is accomplished by the bidirectional switching. Additionally, the series transformer primary and circuit inductances can beneficial, additives in the formation of the total resonant inductor value. This not only reduces size, but incorporates the detrimental parasitic generally snubbed in square wave designs, further enhancing efficiency.
U-138
A new series of control ICs has been developed specifically for the zero voltage switching techniques with a list of features to facilitate lossless switching transitions with complete fault protection. The multitude of functions and ease of programmability greatly simplify the interface to this new generation of power conversion techniques; those developed in response to the demands for increased power density and efficiency.
APPLICATION NOTE
References Forward Converter Vinciarelli, [1] P. Switching At Zero Current, U.S. Patent # 4,415,959 (1983) [2] K. H. Liu and F. C. Lee, Resonant Switches - a U n i f i e d A p p r o a c h t o I m proved Performances of Switching Converters, International Telecommunications Energy Conference; New Orleans, 1984 K. H. Lieu, R. Oruganti, F. C. Lee, Resonant Switches - Topologies and Characteristics, IEEE PESC 1985 (France) M. Jovanovic, D. Hopkins, F. C. Lee, Design Aspects For High Frequency Off-line Quasi-resonant Converters, High Frequency Power Conference, 1987 [5] D. Hopkins, M. Jovanovic, F. C. Lee, F. Stephenson, T w o M e g a h e r t z O f f - L i n e Hybridized Quasi-resonant Converter, IEEE APEC Conference, 1987 W. M. Andreycak, 1 Megahertz 150 Watt Resonant Converter Design Review, Unitrode Power Supply Design Seminar Handbook SEM-600A, 1988 A. Heyman, Low Profile High Frequency Off-line Quasi Resonant Converter, IEEE 1987 W. M. Andreycak, UC3860 Resonant Control IC Regulates Off-Line 150 Watt Converter Switching at 1 MHz, H i g h Frequency Power Conference 1989 [9] M. Schlect, L. Casey, Comparison of the Square-wave and Quasi-resonant Topologies, IEEE APEC Conference, 1987 [10] M. Jovanovic, R. Farrington, F. C. Lee, Comparison of Half-Bridge, ZCS-QRC and ZVS-MRC For Off-Line Applications, IEEE APEC Conference, 1989 [11] M. Jovanovic, W. Tabisz, F. C. Lee, Zero Voltage-Switching Technique in HighFrequency Off-Line Converters, I E E E PESC, 1988
U-138
[12] R. Steigerwald, A Comparison of HalfBridge Resonant Converter Topologies, IEEE 1987 [13] J. Sabate, F. C. Lee, Offline Application of the Fixed Frequency Clamped Mode Series-Resonant Converter, IEEE APEC Conference, 1989 [14] W . T a b i s z , F . C . L e e , Z e r o V o l t a g e Switching Multi-Resonant Technique - a Novel Approach to Improve Performance of High Frequency Quasi-Resonant Converters, IEEE PESC, 1988 [15] W. Tabisz, F. C. Lee, A Novel, ZeroVoltage Switched Multi-Resonant Forward Converter, High Frequency Power Conference, 1988 [16] L. Wofford, A New Family of Integrated Circuits Controls Resonant Mode Power Converters, Power Conversion and Intelligent Motion Conference, 1989 [17] W. Andreycak, Controlling Zero Voltage Switched Power Supplies, High Frequency Power Conference, 1990 [18] R. B. Ridley, F. C. Lee, V. Vorperian, Multi-Loop Control for Quasi-Resonant Converters, High Frequency Power Conference Proceedings, 1987 Additional References: l High Frequency Resonant, Quasi-Resonant and Multi-Resonant Converters, Virginia Power Electronics Center, (Phone # 703-9614536), Edited by Dr. Fred C. Lee l Recent Developments in Resonant Power Conversion, Intertec Communication Press (Phone # 805-658-0933), Edited by K Kit Sum
[3]
[4]
[6]
[7]
[8]
3-352
APPLICATION NOTE
U-138
10 ' Zero Voltage Switching Calculations and Equations 20 ' Using the Continuous Current Buck Topology 30 ' in a Typical DC/DC Converter Power Supply Application 40 ' 50 PRINTER$ = "lptl:": ' Printer at parallel port #l ********** 60 ' 70 ' Summary of Variables and Abbreviations 80 ' 90 ' Cr = Resonant Capacitor 100 ' Lr = Resonant Inductor 110 ' Zr = Resonant Tank Impedance 120 ' Fres = Resonant Tank Frequency (Hz) 130 ' 140 ' VImin = Minimum DC Input Voltage 150 ' VImax = Maximum DC Input Voltage 160 ' Vdson = Mosfet On Voltage = Io*Rds 170 ' Rds = Mosfet On Resistance 180 ' Vdsmax = Peak MOSFET Off State Voltage 190 Vo = DC Output Voltage 200 ' Vdo = Output Diode Voltage Drop 210 ' Iomax = Maximum Output Current 220 ' Iomin = Minimum Output Current 230 ' 240 ' Start with parameters for low voltage dc/dc buck regulator 250 ' 260 ' ****Define 5 Vi and 5 Io data points ranging from min to max***** 270 ' (Suggestion: With broad ranges, use logarithmic spread) 280 DATA 18,20,22,24,27 : 'Vi data 290 DATA 2.5,4,6,8,10 : Io data 300 FRES = 500000! 310 VO = 5! 320 VDO = .8 330 RDS = .8 340 SAFT = .95 350 ' 360 FOR J = 1 TO 5: READ VI(J): NEXT 370 FOR K = 1 TO 5: READ IO(K): NEXT 380 CLS 390 PRINT "For output to screen, enter 'S' or 'S'." 400 INPUT "Otherwise output will be sent to printer : ", K$ 410 IF K$ = "S" OR K$ = "s" THEN K$ = "scrn:" ELSE K$ = PRINTER$ 420 OPEN K$ FOR OUTPUT AS #1: CLS 430 PRINT #1, "================================================" 440 PRINT #1, "Zero Voltage Switching Times (uSec) vs. Vi, I O 450 PRINT #1,"==========================================================" 460 '
3-353
APPLICATION NOTE
U-138
470 ' '========HERE GOES======== 480 ' 490 VIMAX = VI(5): IOMIN = IO(1): IOMAX = IO(5) 500 ZR = (VIMAX - (RDS * IOMIN)) / (IOMIN * SAFT) 510 WR = 6.28 * FRES 520 CR = 1 / (ZR * WR) 530 LR = ZR / WR 540 ' 550 FOR J = 1 TO 5: VI = VI(J) Input Voltage = ###.## V"; VI 560 PRINT #l, USING " 570 FOR K = 1 TO 5: IO = IO(K) 580 RSIN = (VI / (IO * ZR)): VDSON = RDS * IO 590 ' 600 D(0, K) = IO * .00000l: ' Compensate for later mult. by 10^6 610 D(l, K) = (CR * VI) / IO: 'dtO1 620 D(2, K) = (3.14 / WR) + (1 / WR) * ATN(RSIN / (1 - RSIN ^ 2)): dt12 630 D(3, K) = (2 * LR * IO) / VI: 'dt23 640 D(6, K) = D(1, K) + D(2, K) + D(3, K): ' dt03 650 D(4, K) = ((VO + VDO) * D(6, K)) / ((VI - VDSON) - (VO + VDO)): 'dt34 660 D(5, K) = D(1 K) + D(2, K) + D(3, K) + D(4, K): 'Tconv 670 NEXT K 680 ' 690 PAR$(0) = Io (A) =" 700 PAR$(l) = dt01 =" 710 PAR$(2) = dt12 =" 720 PAR$(3) = "dt23 =" 730 PAR$(4) = "dt34 =" 740 PAR$(5) = "Tconv =" 750 PAR$(6) = "dt03 =" 760 ' FOR P = 0 TO 6 770 780 PRINT #1, PAR$(P); 790 FOR K = 1 TO 5 800 PRINT #l, USING " ####.###"; D(P, K) * l000000!; NEXT K: PRINT #l, 810 820 NEXT P 830 PRINT #l, 840 NEXT J 850 ' 860 PRINT #l, "Additional Information: 870 PRINT #l, Zr(Ohms) =; INT(l000! * ZR) / 1000 880 PRINT #l, wR(KRads)=; INT(WR / 1000) 890 PRINT #l. "Cr(nF) =; INT((l000 * CR) / 10 ^ -9) / 1000 900 PRINT #l, Lr(uH) ="; INT((1000 * LR) / 10 ^ -6) / 1000 910 PRINT #l, Vdsmax ="; VIMAX * (1 + IOMAX / IOMIN) 920 END
3-354
APPLICATION NOTE
U-138
I O (A) dt01 dt12 dt23 dt34 Tconv dt03 I O (A) dt01 dt12 dt23 dt34 Tconv dt03 I O (A) dt01 dt12 dt23 dt34 Tconv dt03 Io (A) dt01 dt12 dt23 dt34 Tconv dt03 I O (A) dt01 dt12 dt23 dt34 Tconv dt03
= = = = = = = = = = = = = = = = = = =
Input Voltage 2.500 4.000 0.218 0.136 1.290 1.153 0.931 1.490 1.791 1.387 4.571 3.825 2.439 2.780 Input Voltage 2.500 4.000 0.242 0.151 1.339 1.175 0.838 1.341 1.150 1.406 3.569 4.074 2.419 2.667 Input Voltage 2.500 4.000 0.266 0.166 1.390 1.198 0.762 1.219 1.153 0.988 3.406 3.737 2.418 2.584 Input Voltage 2.500 4.000 0.290 0.182 1.442 1.223 0.698 1.117 0.870 0.975 3.498 3.301 2.431 2.522 Input Voltage 2.500 4.000 0.204 0.327 1.264 0.516 0.993 0.621 0.442 0.793 1.906 3.254 1.464 2.461
V 8.000 10.000 0.068 0.054 1.070 1.056 2.980 3.725 4.118 6.677 8.236 11.511 4.118 4.835 10.000 0.061 1.062 3.352 4.186 8.661 4.475 10.000 0.067 1.069 3.048 2.958 7.141 4.183 10.000 0.073 1.075 2.794 2.241 6.183 3.941 10.000 0.082 1.085 2.483 1.604 5.254 3.650
= 20.00 V 8.000 6.000 0.076 0.101 1.079 1.108 2.011 2.682 1.987 2.852 5.207 6.688 3.220 3.836 = 22.00 6.000 0.111 1.120 1.829 1.557 4.616 3.060 = 24.00 6.000 0.121 1.133 1.676 1.268 4.199 2.930 = 27.00 6.000 0.136 1.153 1.490 0.983 3.763 2.780 V 8.000 0.083 1.087 2.438 2.136 5.744 3.608 V 8.000 0.091 1.096 2.235 1.682 5.103 3.421 V 8.000 0.102 1.109 1.987 1.253 4.451 3.198
= = = = = = = = = = = = = =
Additional Information: Zr(Ohms) = 10.526 wR(KRads)= 3140 Cr(nF) = 30.254 = 3.352 Lr(uH) Vdsmax = 135
UNITRODE CORPORATION 7 CONTINENTAL BLVD.. MERRIMACK, NH 03054 TEL. (603) 424-2410. FAX (603) 424-3460
3-355
IMPORTANT NOTICE Texas Instruments and its subsidiaries (TI) reserve the right to make changes to their products or to discontinue any product or service without notice, and advise customers to obtain the latest version of relevant information to verify, before placing orders, that information being relied on is current and complete. All products are sold subject to the terms and conditions of sale supplied at the time of order acknowledgement, including those pertaining to warranty, patent infringement, and limitation of liability. TI warrants performance of its semiconductor products to the specifications applicable at the time of sale in accordance with TIs standard warranty. Testing and other quality control techniques are utilized to the extent TI deems necessary to support this warranty. Specific testing of all parameters of each device is not necessarily performed, except those mandated by government requirements. CERTAIN APPLICATIONS USING SEMICONDUCTOR PRODUCTS MAY INVOLVE POTENTIAL RISKS OF DEATH, PERSONAL INJURY, OR SEVERE PROPERTY OR ENVIRONMENTAL DAMAGE (CRITICAL APPLICATIONS). TI SEMICONDUCTOR PRODUCTS ARE NOT DESIGNED, AUTHORIZED, OR WARRANTED TO BE SUITABLE FOR USE IN LIFE-SUPPORT DEVICES OR SYSTEMS OR OTHER CRITICAL APPLICATIONS. INCLUSION OF TI PRODUCTS IN SUCH APPLICATIONS IS UNDERSTOOD TO BE FULLY AT THE CUSTOMERS RISK. In order to minimize risks associated with the customers applications, adequate design and operating safeguards must be provided by the customer to minimize inherent or procedural hazards. TI assumes no liability for applications assistance or customer product design. TI does not warrant or represent that any license, either express or implied, is granted under any patent right, copyright, mask work right, or other intellectual property right of TI covering or relating to any combination, machine, or process in which such semiconductor products or services might be or are used. TIs publication of information regarding any third partys products or services does not constitute TIs approval, warranty or endorsement thereof.