0% found this document useful (0 votes)
247 views10 pages

System 8000

This document summarizes the features and specifications of an 8000 series fire alarm system. It includes details on the control panel, detectors, sounders, call points and accessories. The system allows networking of up to 31 panels and features flexible input/output capabilities and time-based detector functions. It also has robust commissioning and diagnostic tools for remote programming and fault analysis.

Uploaded by

ayad60
Copyright
© Attribution Non-Commercial (BY-NC)
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
247 views10 pages

System 8000

This document summarizes the features and specifications of an 8000 series fire alarm system. It includes details on the control panel, detectors, sounders, call points and accessories. The system allows networking of up to 31 panels and features flexible input/output capabilities and time-based detector functions. It also has robust commissioning and diagnostic tools for remote programming and fault analysis.

Uploaded by

ayad60
Copyright
© Attribution Non-Commercial (BY-NC)
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 10

(68.

52)

June 2000 supersedes January 2000

system

8000
& ALARM SYSTEMS .

ADDRESSABLE FIRE DETECTION

w e l o o k @ b u s i n e s s d i ff e re n t l y

S Y S T E M

A R C H I T E C T U R E

External Devices

8000 Fire Alarm Control Panel External Devices Optic Fibre External Devices

Max. 1 km

Conventional Fire Alarm System

Network up to 31 panels
Sensor External Devices Slave LED (mimics LED of next device)
Max. 1km Booster (to increase distances between panels) External Devices Graphics Display Max. 1km

Beam Detector
Repeat Indicator Printer

9200 Detector Series Non Fire Application eg. Fire Exits Call Point Sounder Controller

Up to 7 loops per panel

4 Zone, 2 Relay Transponder

9000 Conventional Detector Series

1 Zone Transponder 32 LED Outputs Transponder

Sounders

Mimic

Note: 1). Max. 127 devices per loop, 512 devices per panel. 2). Maximum loop length is 1km. 3). This schematic is for guidance only please refer to product instructions during installation.

8 0 0 0

F E AT U R E S

&

B E N E F I T S

Powerful Commissioning and Servicing Tools


A comprehensive suite of tools to support the commissioning, installation and maintenance of the system. This includes remote access for interrogation and service via a modem, wiring integrity checks and fireplan simulation.

Multicriteria Sensing
The multicriteria sensor detects fire in 3 different ways (Optical /Heat/Ion). Diagnosis is therefore more accurate than any single method of detection.

Create Seamless Networks


Connect up to 31 panels together and retain control on large or complex sites. Also, new buildings or extensions are easily accommodated on the existing system.

Clear User Information


Display information is customised to the site requirements. Messages and actions are clear and understandable to the user.

Flexible Alarm Settings


Sounder circuits are run off transponders on the panel loop. This saves money over conventional sounder wiring and allows flexibility since each circuit may be programmed to sound individually in the event of an alarm.

Disable Button for Weekly Test


BS 5839 calls for weekly testing of the fire alarm system. Outputs to critical plant such as boiler controls however can be disabled simply without affecting the general test.

Timed Solutions
Detector functions can be switched on or off at varying times to suit the buildings use. For instance, a detector could operate as a heat detector during periods when the building is occupied then as a smoke, ionisation and heat detector when no one is present to spot smoke.

Flexible Input and Output Features


System 8000 has flexible fire and non-fire switching capabilities e.g. fire exits may be monitored. Opening such an exit could be registered at the control panel or activate a beacon output to alert staff.

TELE-DIAGNOSTIC

PROGRAM

(TEDIS)

Tedis allows an engineer to interrogate, diagnose and rectify problems on the fire system without having to be present on site. Using a PC and modem the engineer can dial into the control panel from any location even while on the move. Status identification and modification of the following are easily achieved;  All control panel data  Loop device data  All customer specific configurations This advance knowledge assists the engineer to arrive on site fully prepared with the required materials, manpower and tools to complete the work first time. Tedis can also be used to provide remote assistance to a user over the telephone.  Operation  Fault finding & rectification

TEDIS

Interrogate, diagnose and rectify problems on the fire system without having to be present on site.

8 0 0 0

C O N T R O L

PA N E L

The 8000 control panel and devices are designed to offer an affordable solution to the protection of buildings with complex fire safety needs. A text display combined with LED indicators will clearly pinpoint a fire or fault condition. An historic log remembers the latest 200 events and there are printer and zonal display options. Panels comply with BS EN54 and are compatible with the requirements of BS 5839 part 1. They are approved by the demanding VdS testing authority and LPC approval is applied for.
8000 Control Panel

Technical Specification - Control Panel


Mains voltage Power supply unit Operating voltage Quiescent current consumption Emergency power supply Operating temperature Weight Ingress Protection Max Number of loops per panel Standby period 230 V/ 50-60 Hz 12 V / 3.5 A 9 - 19 VDC max. 150 mA 12V, 2 x 12 Ah (2 x 24 Ah in extension housing) 0 C to 50 C appr. 6.5 kg (Without batteries) IP 30 7 24hrs + 30minutes alarm, upgradeable to 72 hours

S P E C I A L F E AT U R E
The control panel has a unique bypass circuit. In a catastrophic event such as a lightning strike damaging the microprocessor, the panel will switch to a 2 state system and continue to provide detection for the building and its occupants.

ORDER CODES Dimensions (mm)


206

1 Loop 1 Loop c/w Zone Indication


Mounting Box

788111 788112 788113 788104 788105 788106

1 Loop c/w Printer 2 Loop 2 Loop c/w Zone Indication 2 Loop c/w Printer

320

Extension housing for 2 x 12V / 24Ah batteries (optional)


450 179

Mounting Box

All units supplied with 1 loop card. For customised versions see back cover.

320

8 0 0 0

O U T S TAT I O N S

Sensors
Ionisation Quiescent Current Approximate Weight Ingress Protection Applicable Standard Operating Temperature 45A 100g IP40 BS EN54, Pt 7 -20 to +60C Fixed Temperature Heat 45A 100g IP40 BS EN54, Pt 5 -20 to +72C Rate of rise Heat 45A 100g IP40 BS EN54, Pt 5 54 to 62C, 1C/min 45 to 64C, 5C/min 32 to 72C, 30C/min Approvals* Dimensions (mm) Order Codes VdS 90 dia x 61 761071 VdS 90 dia x 61 761171 VdS 90 dia x 61 761271 VdS 90 dia x 61 761371 VdS 90 dia x 61 761373 VdS 90 dia x 61 761973 Optical 45A 100g IP40 BS EN54, Pt 7 -20 to +72C OT Multisensor OTI Multisensor 45A 100g IP40 45A 100g IP40

BS EN54,Pt 7 BS EN54, Pt 5or7 -20 to +72C -20 to +72C

* LPC pending. Contact Gent 24 for details.

Volumatic Sensors
S P E C I A L F E AT U R E
Quiescent Current Beam Receiver 8mA Transmitter 5mA 3.2Kg IP30 BS 5839 Part 5 -20 to +55C 10 - 100m N/A Controller 210W x 260H x145D 07011-41 Duct 45 700g IP54 BS EN54 -20 to +60C N/A LPCB 120W x 110H x 300D Housing 781453 Venturi Tube 0.6m 781456 Venturi Tube 1.5m 781457 Venturi Tube 2.8m 781458

All sensors carry a unique serial number for backwards traceability. It is therefore possible to see a complete log of events for a particular device such as when it was last reworked, cleaned or how many fire conditions it has detected.

Approximate Weight Ingress Protection Applicable Standard Operating Temperature Beam Length Approvals Dimensions (mm) Order Code

PA N E L

O R D E R

C O D E S

1. SELECT DOUBLE FIRST FIX HOUSING. 2. SELECT 1 OPERATING MODULE FOR EACH HOUSING FROM THE OPTIONS LIST ON THIS PAGE. 3. 1 LOOP CARD SUPPLIED AS STANDARD PLEASE ORDER ADDITIONAL CARDS AS REQUIRED. 4. FOR SURFACE CABLING IT IS NECESSARY TO ORDER 2 x 789310 EXTENSION BOXES.

ORDER CODE Standard Panel. 786050

Standard Panel complete 786150 with 64 Zone Indication.

Upper Housing Options

Standard Panel complete 786450 with extended LCD display.

Code 788299 First Fix comprising double housing, 2 neutral fronts and 1 loop card

Standard Panel complete 786550 with 64 Zone indication & extended LCD display.

Neutral front

742838

192 Zone indication

786000

Lower Housing Options

Neutral Front

742838

P R I N T E R

O P T I O N S

1. SELECT DOUBLE FIRST FIX HOUSING. 2. SELECT 1 OPERATING MODULE FOR EACH HOUSING FROM THE OPTIONS LIST ON THIS PAGE. 3. 1 LOOP CARD SUPPLIED AS STANDARD PLEASE ORDER ADDITIONAL CARDS AS REQUIRED. 4. FOR SURFACE CABLING IT IS NECESSARY TO ORDER 3 x 789310 EXTENSION BOXES.

The printer options must be mounted in the upper housing.


ORDER CODE Standard Panel with printer c/w housing. 789398

Standard Panel with printer and take up spool c/w housing.

789399

Printer option (supplied complete with housing).

Neutral front

742838

Code 788299 First Fix comprising double housing, 2 neutral fronts and 1 loop card

192 Zone indication

786000

LOOP CARDS Single loop card Network card 784382 784840

Note: First Fix items include one loop card and capacity for 4 loops + 1 network or 5 loops. For 6 or 7 loops it is necessary to order the extension module 772421.

8 0 0 0

O U T S TAT I O N S

Sensor Bases and Ancillaries Order Codes


Sensor base Sensor base with relay output Sensor base with isolator Sensor base with surface mount adaptor Sensor lock Sensor protective cage Sensor base adaptor for flush mounting Sensor base adaptor for conduits Sensor removal tool Sensor dust cover 781415 781417 781416 781495 781496 781550 781497 781498 769804 789855

Sounders
Operation

Note - Sounder outputs are variable dependent upon tone choice. Shallow Base Continuous 9 - 28V DC 93dBA 100dBA 8mA @ 12V, 18mA @ 24V IP54 0.29kg 93 dia x 75 deep 74451-24NM Deep Base (IP65) Continuous 9 - 28V DC 93dBA 100dBA 8mA @ 12V, 18mA @ 24V IP65 0.31kg 93 dia x 105 deep 74452-24NM Bedhead Sounder Continuous 9 - 28V DC 94dBA 97dBA 8mA @ 12V, 18mA @ 24V IP54 0.11kg 86 square x 42 deep 74455-24NM Sounder Base Continuous 10 - 28V DC 87dBA 93dBA 8mA @ 12V, 18mA @ 24V IP54 0.15kg 112 dia x 30 deep 74456-24NM

Operating Voltage Range Typical Sound Output @ 1m, 12V DC Typical Sound Output @ 1m, 24V DC Current Consumption IP Rating Approximate Weight Dimensions (mm) Order Code

Manual Call Points


Approximate Weight IP Rating Dimensions (mm) Order Codes

Note - Standard & Key operated MCPs require a surface (706080) or flush (706081) box. Standard 0.17kg IP54 IP65 470g IP65 123W x 120H x 80D 706022 Key Operated 0.17kg IP54 88 square x 55 deep 706021 Hinged Cover Suitable for standard and key operated versions 706901

88 square x 55 deep 706120 with isolator 706220 without isolator

Transponder Interfaces
Sounder Controller Description 2 Sounder circuits (0.5A), individually controlled sectors Aux 24V @0.5A 12 Relay 12 relay outputs 32 LED 32 outputs to drive LEDs 4/2 4 detector zones/ 2 relay outputs 1 Zone Single detector zone

Max No. per loop Approximate Weight Ingress Protection Battery Supply Operating Temperature Dimensions (mm) Order Code 3.3Kg IP31

Up to 100 interfaces per control panel. Max 32 per zone on an analogue loop 95g IP50 95g IP50 380g IP50 380g IP50

2 x 12V 2.1 Ah -20C to +50C 317Wx248Hx83D 788618 -20C to +70C 189Wx131Hx47D 788610 -20C to +70C 189Wx131Hx47D 788611 -20C to +50C 189Wx131Hx47D 788616 -20C to +50C 189Wx131Hx47D 788617

GENT 24 Waterside Road, Hamilton Industrial Park, Leicester LE5 1TN. Tel: 0800 013 8824 Fax: 0800 013 8825 Gent 24 products are available through a network of approved system integrators.
A Caradon Company 8000/4M/6/00