Brosur Genset 2

This document provides specifications for Alturdyne liquid cooled diesel generator sets ranging from 40-400kW. The generator sets consist of a diesel engine coupled to an electric generator assembled on a structural steel skid. The generators are four pole, brushless machines that meet NEMA and international standards. The diesel engines are in-line, multi-cylinder engines that can be naturally aspirated, turbocharged, or turbocharged with air/water aftercooling. Optional equipment includes special voltages, PMG excitation, temperature rise generators, control systems, and enclosures. Dimensions and technical specifications like fuel consumption, cooling requirements, and emissions are provided for each generator set model.

Uploaded by

Angga Clevnezt
Copyright
© Attribution Non-Commercial (BY-NC)
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
254 views2 pages

Brosur Genset 2

This document provides specifications for Alturdyne liquid cooled diesel generator sets ranging from 40-400kW. The generator sets consist of a diesel engine coupled to an electric generator assembled on a structural steel skid. The generators are four pole, brushless machines that meet NEMA and international standards. The diesel engines are in-line, multi-cylinder engines that can be naturally aspirated, turbocharged, or turbocharged with air/water aftercooling. Optional equipment includes special voltages, PMG excitation, temperature rise generators, control systems, and enclosures. Dimensions and technical specifications like fuel consumption, cooling requirements, and emissions are provided for each generator set model.

Uploaded by

Angga Clevnezt
Copyright
© Attribution Non-Commercial (BY-NC)
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 2

Diesel Generator Sets

Liquid Cooled, Four-Cycle

40 to 400kW / 60 Hz
50 Hz: (.83) x 60 Hz Ratings

DESCRIPTION: Alturdyne Basic Model ARDJ-XXX (kW rating)-060-H* 2001 RATINGS


Package Configuration

Generator

- Basic package consists of diesel engine


coupled to generator and assembled on
structural steel skid with unit mounted radiator
and pusher fan, control panel and accessories.
Electronic governor is standard along with flex
fuel lines and fuel/water separator and base
isolation pads.

- Generators are four pole, brushless broad


range machines with a single permanently
lubricated, double shielded radial ball bearing
and flywheel disc drive coupling. The revolving
field design contains a direct drive exciter and
stator windings are 2/3 pitch with vacuum epoxy
impregnation. Design is to NEMA and
International Standards and insulation is either
Class F or H. Generators feature a TIF of <50,
low radio interference, a wave form deviation of
<5%, harmonic content of 3% max and a
voltage regulation of 1% with standard static
regulator.

- The Alturdyne designed/manufactured engine


and generator control panel is unit mounted and
contains ammeter, voltmeter, AM/VM select
switch, frequency meter, voltage adjust rheostat,
oil pressure gauge, water temperature gauge,
three-position mode switch, panel lights, cycler
crank with safeties for overspeed, low oil
pressure, high water temperature and
overcrank. Customer connections and remote
alarms are located on isolated terminal strip.
- Generator leads terminate in an oversize box
or at back of circuit breaker located in adjacent
NEMA 1 box.

Engine
- All engines are in-line, multi-cylinder diesels
with direct injection and have replaceable wet
liners. Units are either naturally aspirated (NA),
turbocharged (T), turbocharged with air
aftercooling (TA) or turbocharged with water
aftercooling (TW). Rotary (R) or in-line (I)
injection pumps are used. Emissions and
acoustics are low. Accessories include fuel
pump, primary and secondary fuel filters, lube oil
pump and cooler, lube oil filter, water pump,
exhaust manifold, jacket water heater, stainless
flex exhaust coupling, insulation blankets, DC
starter and battery charging alternator.

Optional Equipment
- Special voltages up to 600 volts and DC.
The following codes are used:
G - 120/240 single phase
P - 120/208 three phase
R - 277/480 three phase
S - 346/600 three phase
E - 220/380 three phase
X - Special (4,160)
D - DC (Direct Current)
- PMG is available along with 3 phase sensing
which includes a parallel module and
overvoltage protection with engine relief load
acceptance. Additional RF protection is
available.
- Special array of temperature rise (80C and
130C) generators available meeting NEMA
MG1-22.84 standards.

- Custom designed control systems - Special


metering - Bussing - Switch gear - Remote
annunciator.
- Circuit breaker is an insulated case mounted in
a NEMA 1 Box.
- Cooling: Remote radiator/hotwell tank - Heat
exchanger.
- Fuel Systems: Pumps - Valves - Tanks (single
and double wall, separate or skid mounted) switches - water separators.
- Batteries: Lead acid - Lead calcium - Nickel
cadmium - Heated boxes - Trickle chargers.
- Enclosures: Weather resistant - Thermal
insulated - Sound attenuated - Spring isolation.
- Mechanical governing.
- Prime power ratings.
- Radiator load banks.
- Spares.
- Loose ship kits.
- Transfer Switches
- Extended Warrantee / Service

SPECIFICATIONS: 40-400KW - DIESEL GENERATOR SET - LIQUID COOLED - FOUR CYCLE - JOHN DEERE ENGINE - 2001 RATINGS
RATINGS (Standby) 6

English / Metric

Engine Model - Configuration


Cylinders / Type Injection Pump

40KW1

60KW2

75KW2

100KW2

125KW2

150KW4

180KW4

200KW5

250KW5

300KW5

350KW5

400KW5

4045DF150

4045TF150

4045TF250

6068TF150

6068TF150

6081AF001

6081AF001

6081AF001

6081HF001

6125HF001

6125HF001

6125HF001

4/Rotor

4/Rotor

4/Rotor

6/Rotor

6/Rotor

6/Inline

6/Inline

6/Inline

6/Inline

6/Unit E.C.

6/Unit E.C.

6/Unit E.C.
766/12.5

cu in/l

276/4.5

276/4.5

276/4.5

414/6.8

414/6.8

496/8.1

496/8.1

496/8.1

496/8.1

766/12.5

766/12.5

1800rpm / 1500rpm

71/59

100/83

122/111

165/137

198/165

250/210

300/250

347/302

413/359

483/405

563/472

716/596

psi / kPa

113/781

160/1105

194/1341

167/1150

202/1395

222/1530

266/1835

308/2126

368/2538

277/1910

323/2227

353/2436

gal/hr / l/hr

3.6/13.8

4.9/18.5

6.1/23.3

8.1/30.6

9.3/35.2

11.8/44.7

14.4/54.7

16.9/64

19.5/74.2

20.3/77.2

25.1/95.3

30.8/117

qt / l

9/8.5

14/13.2

14/13.2

18/17

18/17

34/32

34/32

34/32

34/32

44/42

44/42

44/42

Engine Jacket Water Capacity

gal / l

2.25/8.5

2.25/8.5

2.25/8.5

3/11.3

3/11.3

4/15

4/15

4/15

3.75/14

4.3/16.2

4.3/16.2

4.3/16.2

Engine & Radiator Capacity

gals / l

3.9/14.7

4.1/15.7

5.55/21.2

6.3/24.0

6.3/24.0

14.5/55.2

14.5/55.2

TBA

TBA

18.1/68.2

18.1/68.5

18.1/68.5

gal/min / l /min

38/144

38/144

38/144

46/174

46/174

71/270

71/270

75/285

71/270

73/276

73/276

73/276

Displacement
Horsepower
BMEP (1800 rpm Standby)
Fuel Consumption (Full Load)
Oil Sump Capacity 10

Water Pump Flow

F / C

1103/595

946/508

1026/552

1011/544

1112/600

1060/570

1020/550

927/497

957/514

743/395

815/435

936/502

cfm / m3/m

318/9

480/13.6

614/17.4

787/22.3

918/26.0

1210/34.3

1695/48

1854/52.5

2052/58.1

2295/65

2755/78

3069/87

Engine Heat Rejection

BTUM / kW

1820/32

2445/43

2959/52

3869/68

4324/76

6170/108

7390/130

8251/145

5485/96

7654/135

9820/173

9502/167

Air Flow (room), Remote Cooling

cfm / m3/m

2120/60

2750/78

3030/86

6893/195

8760/248

6100/173

7240/205

8970/254

11050/313

13650/386

16050/454

17500/496

Combustion Airflow

cfm / m3/m

117/3.3

187/5.3

230/6.5

297/8.4

325/9.2

440/12.5

635/18

756/21.4

749/21.2

1024/29

1180/33.5

1280/36.2

Genset Radiated Heat

BTUM / kW

952/17

1234/22

1364/24

1475/25.9

1661/29.2

2749/48

3259/57

4036/71

4972/87

6145/108

7226/127

8258/145

12/24

12/24

12/24

12/24

12/24

12/24

12/24

12/24

12/24

24

24

24

640/570

640/570

640/570

800/570

800/570

800/570

800/570

800/570

800/570

900

900

900

Exhaust Gas Temp (Stack)


Exhaust Gas Flow

Electrical System Voltage


Recommended Battery (32F/-0C) CCA (12V/24V)

DIMENSIONS AND WEIGHT


Diameter Exhaust Outlet, External

in / cm

2.43/6.20

4. 0/10.16

4.0 /10.16

4.0/10.16

4.0/10.16

4.0/10.16

4.0/10.16

4.0/10.16

4.0/10.16

4.0/10.16

4.0/10.16

4.0/10.16

Length, Overall (L) *

in / cm

72/183

76/193

76/193

90/229

90/229

96/244

96/244

96/244

120/305

120/305

120/305

120/305

Width, Skid (WS) *

in / cm

32/81

32/81

32/81

32/81

32/81

32/81

32/81

32/81

36/91

36/91

36/91

36/91

Radiator Core Duct (RW) x (RH) *

in / cm

20x20/51x51

26x28/66x71

26x28/66x71

26x28/66x71

26x28/66x71

28x30/71x76

28x30/71x76

28x30/71x76

32x36/81x91

45x40/114x102

45x40/114x102

45x40/114x102

Height, Spring (HS) *

in / cm

5/12.7

5/12.7

5/12.7

5/12.7

5/12.7

5/12.7

5/12.7

5/12.7

5/12.7

5/12.7

5/12.7

5/12.7

Height, Overall (H) *

in / cm

64/163

64/163

64/163

64/163

64/163

66/168

66/168

66/168

68/173

70/178

70/178

70/178

Height, Injectors (HI) *

in / cm

36/91

36/91

36/91

36/91

36/91

38/96.5

38/96.5

38/96.5

42/107

42/107

42/107

42/107

Radiator Center (RC) *

in / cm

30/76

35/89

35/89

35/89

35/89

37.5/95

37.5/95

37.5/95

39/99

39/99

39/99

39/99

CEN *

in / cm

19/48

19/48

19/48

19/48

19/48

21/53

21/53

21/53

24/61

24/61

24/61

24/61

Dry Weight *

lb / kg

2050/930

2450/1111

2550/1157

2477/1124

2477/1124

3550/1610

3550/1610

4150/1882

4400/1996

5850/2654

5850/2654

6500/2954

01:
02:
03:
04:
05:
06:
07:
08:
09:
10:
11:

Derate 3.0% per 1,000 feet (305 m.) above 600 feet (183 m.) and 1.5% per 10F (5.5C) above 77F (25C)
Derate 3.0% per 1,000 feet (305 m.) above 500 feet (153 m.) and 0.5% per 10F (5.5C) above 77F (25C)
Derate 3.0% per 1,000 feet (305 m.) above 7,500 feet (2,236m.) and 0.5% per 10F (5.5C) above 77F (25C)
Derate 0.5% per 1,000 feet (305 m.) above 3,300 feet (1,006 m.) and 0.5% per 10F (5.5C) above 77F (25C)
Derate 0.5% per 1,000 feet (305 m.) above 1,000 feet (305 m.) and 0.5% per 10F (5.5C) above 77F (25C)
Derate 10.0% for Prime kW rating. Standby ratings listed are 5% at SAE J1995 and ISO 3046
Materials and specifications may change without notice
Maximum allowable exhaust stack back pressure = 30 inches or 762 mm. water column
Maximum radiator discharge back pressure = 0.5 inches or 12.7 mm. water column
Average oil consumption = 0.0008 lb/Bhp/hr (1 qt = 1.9 lb)
Emissions

ALTURDYNE
660 Steele Street El Cajon, CA 92020
Tel: 619/440-5531
Fax: 619/442-0481
Email: info@alturdyne.com

* Dimensions listed are for reference purposes only. Certified drawings are provided on placement of order.