Bits SGP

The document provides 50 fill-in-the-blank questions related to circuit breakers, grounding systems, transmission lines, and protective relaying. Key terms that must be filled in include current, recovery voltage, 3000C, photo-emission, diffusion and drift, high voltages, short time current, transient voltage, bottom, distribution transformers, low and high resistance, peak value, closing of charged line, magnetically blow out type, same and opposite polarity, resonant earthing, ungrounded systems, intentional impedance, supply end, switching over voltages, do not have, reactance, sensitivity, circuit breakers, fault clearing time, relay time, breaker time, earth fault, line to line fault, over
Copyright
© Attribution Non-Commercial (BY-NC)
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as DOCX, PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
160 views4 pages

Bits SGP

The document provides 50 fill-in-the-blank questions related to circuit breakers, grounding systems, transmission lines, and protective relaying. Key terms that must be filled in include current, recovery voltage, 3000C, photo-emission, diffusion and drift, high voltages, short time current, transient voltage, bottom, distribution transformers, low and high resistance, peak value, closing of charged line, magnetically blow out type, same and opposite polarity, resonant earthing, ungrounded systems, intentional impedance, supply end, switching over voltages, do not have, reactance, sensitivity, circuit breakers, fault clearing time, relay time, breaker time, earth fault, line to line fault, over
Copyright
© Attribution Non-Commercial (BY-NC)
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as DOCX, PDF, TXT or read online on Scribd
You are on page 1/ 4

Circuit Breaker : Fill in the blanks with appropriate words : 1.

A sudden short-circuit in an ac system causes a rise in __________ in the short-circuited phase. Get Answer: (Hide) Current 2. The voltage appearing across the circuit breaker pole after final current zero is called __________ voltage. Get Answer: (Show) Recovery 3. Thermal ionization of gases occurs at temperature around __________ C. Get Answer: (Hide) 3000 4. The electron emission from contact surface caused by incidence of light energy is called __________. Get Answer: (Show) photo-emission 5. De ionization can take place by the processes of recombination or attachment as well as by process of __________ and __________. Get Answer: (Hide) diffusion, drift 6. The behavior of arc in high vacuum is affected by contact material and __________. Get Answer: (Show) conditions of the contact surface 7. Sphere gaps are used for measurement of __________. Get Answer: (Hide) high voltages 8. Current breakers are generally overhauled every __________ years. Get Answer: (Show) three 9. In circuit breakers, arc is extinguished either by __________ the arc __________ the arc or __________ the arc. Get Answer: (Hide) lengthening,cooling,splitting 10. Deterioration of dielectric oil is governed by __________ color. Get Answer: (Show) dark 11. The characteristics of a fuse is governed by material and __________ of the fuse element. Get Answer: (Hide) shape 12. A fuse should generally have a normal rating 25 to 50 percent above the normal full load current to lake care of __________. Get Answer: (Show) switching surges 13. Skin effect is absent in case of __________ current. Get Answer: (Show) direct 14. Insulators operate under __________ conditions. Get Answer: (Hide)

no-load 15. Melting point of aluminium is __________. Get Answer: (Show) 657 0C 16. Density of aluminium is nearly __________ of the density of copper. Get Answer: (Hide) one-third 17. Melting point of copper is __________ 0C. Get Answer: (Hide) 1083 18. Pantograph isolator is preferred for circuits above __________ kV. Get Answer: (Show) 400 19. __________ current is the rms value of the current which a breaker must carry for a stated time. Get Answer: (Hide) short time 20. The insulation requirements of switchgear are determined by __________ voltage. Get Answer: (Hide) transient 21. In horn gaps the arc is produced at the __________ during high voltage surge. Get Answer: (Show) bottom 22. Secondary type lightning arresters are used for the protection of __________ transformers. Get Answer: (Hide) distribution 23. The non-linear resistor in lightning arrester offers __________ resistance to the flow of discharge currents and __________ resistance to power frequency voltage. Get Answer: (Show) low,high 24. The surge current which flows through the lightning arrester after the spark over is expressed in terms of __________ value. Get Answer: (Show) peak 25. The most severe cause of switching over-voltages is __________. Get Answer: (Hide) closing of charged line Get all answers at once: (Show) 1.Current ----- 2.recovery ----- 3.3000 ----- 4.photo-emission ----- 5.diffusion, drift----- 6.Conditions of the contact surface----7.high voltages----- 8.three -----9.lengthening,cooling,splitting -----10.dark -----11.shape ----- 12.switching surges-----13.direct -----14.no-load ----- 15. 657 0C ----- 16. one-third----- 17.1083 ----- 18.400 ----- 19.short time----- 20.transient ----- 21. bottom----22.distribution ----- 23.low,high ----- 24.peak ----- 25.closing of charged line

Circuit Breaker : Fill in the blanks with appropriate words : 26 __________ type lightening arresters are designed to discharge the switching over-voltage as well as lightning over-voltages. Get Answer: (Show) 27. Traveling wave gets reflected from short circuited line with reflected current wave of __________ polarity and voltage wave of the __________ polarity. Get Answer: (Show) 28. Peterson coil is the reactance used in __________ earthing. Get Answer: (Show) 29. The phenomena of arcing grounds is commonly experienced with __________ systems. Get Answer: (Show) 30. In solid grounding system, the neutral is connected to ground without any __________ between neutral and ground. Get Answer: (Show) 31. The grounding is generally at the __________ end. Get Answer: (Show) 32. Insulation co-ordination of EHV and UHV line is based on __________. Get Answer: (Show) 33. In delta connected load, the line current return path. Hence line currents __________ zero sequence component. Get Answer: (Show) 34. The negative sequence network has only negative sequence __________. Get Answer: (Show) 35. The smallest value of actuating quantity at which protection starts operating in relation with the minimum value of fault current in the protected zone, is known as __________ of the protective scheme. Get Answer: (Show) 36. Trip circuit is normally a part of __________. Get Answer: (Show) 37. The time elapsed between the instant of occurrence of fault and instant of final arc extinction in circuit breaker is known as __________. Get Answer: (Show) 38. The time interval between occurrence of fault and closure of relay contacts is known as __________. Get Answer: (Show) 39. The lime interval between closure of trip circuit and final arc interruption is known as __________. Get Answer: (Show) 40. Acting ground is also known as __________ fault. Get Answer: (Show) 41. Phase fault is __________ fault. Get Answer: (Show) 42. A relay which responds to increase in current is known as __________.

Get Answer: (Show) 43. Power line carrier is a __________ signal sent through the power line conductors. Get Answer: (Show) 44. Static relays __________ moving parts. Get Answer: (Show) 45. An electro-magnetic relay will operate when operating force is __________ restraining force. Get Answer: (Show) 46. __________ is suitable for outdoor UHV and HV traction system. Get Answer: (Show) 47. The drop off value to pick-up value of a relay is also known as __________. Get Answer: (Show) 48. The holding ratio of a relay is usually __________. Get Answer: (Show) 49. A bimetal strip consists of two metal strips having different __________. Get Answer: (Show) 50. A directional relay senses __________. Get Answer: (Show) Get all answers at once: (Hide) 26.magnetically blow out type ----- 27.same,opposite ----- 28. resonant ----- 29.ungrounded ----- 30.intentional impedance ----31.supply ----- 32.switching over voltages----- 33.do not have----- 34.reactance ----- 35.sensitivity ----- 36. circuit breakers 37. fault clearing time----- 38. relay time----- 39. breaker time---------- 40.earth ----- 41.line to line----- 42.over current relay----43.high frequency----- 44.do not----- 45. greater than----- 46. Air blast circuit breaker----- 47. holding ratio----- 48. less than 1 ---- 49. coefficient of thermal expansion----- 50. power