Agilent 7500 Series ICP-MS
Customer Maintenance
Parts List
Notices
Warranty
Copyright 2006 Agilent Technologies
The material contained in this
document is provided as is,
and is subject to being changed,
without notice, in future editions. Further, to the maximum
extent permitted by applicable
law, Agilent disclaims all warranties, either express or
implied, with regard to this
manual and any information
contained herein, including but
not limited to the implied warranties of merchantability and
fitness for a particular purpose. Agilent shall not be liable
for errors or for incidental or
consequential damages in connection with the furnishing, use,
or performance of this document or of any information contained herein. Should Agilent
and the user have a separate
written agreement with warranty terms covering the material in this document that
conflict with these terms, the
warranty terms in the separate
agreement shall control.
No part of this manual may be reproduced in any form or by any means
(including electronic storage and
retrieval or translation into a foreign
language) without prior agreement
and written consent from Agilent
Technologies, Inc. as governed by
United States and international copyright laws.
Manual Part Number
G3270-90123
Edition
Rev.B, December 2006
Printed in Japan
Agilent Technologies, Inc.
9-1 Takakura-cho, Hachioji-shi,
Tokyo 192-8510 Japan
Technology Licenses
The hardware and/or software
described in this document are furnished under a license and may be
used or copied only in accordance
with the terms of such license.
Restricted Rights Legend
If software is for use in the performance of a U.S. Government prime
contract or subcontract, Software is
delivered and licensed as Commercial computer software as defined in
DFAR 252.227-7014 (June 1995), or
as a commercial item as defined in
FAR 2.101(a) or as Restricted computer software as defined in FAR
52.227-19 (June 1987) or any equivalent agency regulation or contract
clause. Use, duplication or disclosure
of Software is subject to Agilent
Technologies standard commercial
license terms, and non-DOD Departments and Agencies of the U.S. Government will receive no greater than
Restricted Rights as defined in FAR
52.227-19(c)(1-2) (June 1987). U.S.
Government users will receive no
greater than Limited Rights as
defined in FAR 52.227-14 (June
1987) or DFAR 252.227-7015 (b)(2)
(November 1995), as applicable in
any technical data.
Safety Notices
CAUTION
A CAUTION notice denotes a
hazard. It calls attention to an
operating procedure, practice, or
the like that, if not correctly performed or adhered to, could result
in damage to the product or loss
of important data. Do not proceed
beyond a CAUTION notice until
the indicated conditions are fully
understood and met.
WARNING
A WARNING notice denotes a
hazard. It calls attention to an
operating procedure, practice,
or the like that, if not correctly
performed or adhered to, could
result in personal injury or
death. Do not proceed beyond a
WARNING notice until the
indicated conditions are fully
understood and met.
Agilent 7500 Series ICP-MS
Customer Maintenance
Parts List
Contents
Preface
About the Maintenance Parts P-2
Conventions Used in This Book
P-3
Where to Go for More Information
P-4
Agilent Technologies on the Internet P-4
1 Parts Related to the Peristaltic Pump
Parts Related to the Peristaltic Pump
1-2
2 Parts Related to the Nebulizer
Parts for the Babington Nebulizer 2-2
Parts for the Concentric Nebulizer 2-4
Parts for the Micro Flow Nebulizers 2-6
Parts for the MicroMist Nebulizer 2-8
Burgener Research Mira Mist Nebulizer 2-9
Parts Related to the PFA Concentric Nebulizer
2-10
Parts for the Cross Flow Nebulizer 2-12
Miscellaneous parts for Nebulizer 2-14
3 Parts Related to the Spray Chamber
Parts Related to the Spray Chamber 3-2
C-1
Agilent 7500 Series ICP-MS Customer Maintenance Parts List
Contents
4 Parts Related to the Torch
Parts Related to the Torch
4-2
5 Parts Related to the Interface
Parts Related to the Interface
5-2
6 Parts Related to the Ion Lens and Vacuum Chamber
Parts Related to the Ion Lens and Vacuum Chamber 6-2
7 Parts Related to the 7500ce
Parts Related to the 7500ce
7-2
8 Parts Related to the 7500cs
Parts Related to the 7500cs
8-2
9 Miscellaneous Components
Miscellaneous Components 9-2
10 Parts related to the Integrated Sample Introduction System (ISIS)
Parts Related to the Integrated Sample Introduction System (ISIS) 10-2
Parts Related to the Hydride Generator Accessory
C-2
10-7
Agilent 7500 Series ICP-MS Customer Maintenance Parts List
Contents
11 Parts Related to the GC-ICP-MS Interface
Parts Related to the GC-ICP-MS Interface
11-2
12 Parts Related to the Integrated Auto Sampler (I-AS)
Parts Related to the I-AS (Integrated Auto Sampler) 12-2
13 Parts Related to the ASX-500 Series ICP-MS Autosampler
Parts Related to the Agilent ASX-500 Series ICP-MS Autosampler 13-2
C-3
Agilent 7500 Series ICP-MS Customer Maintenance Parts List
Contents
C-4
Preface
Agilent 7500 Series ICP-MS Customer Maintenance Parts List
Preface
Preface
The Agilent 7500 Series ICP-MS Customer Maintenance Parts List explains the
maintenance parts for use with the Agilent 7500, the Integrated Sample Introduction
System (ISIS), Integrated Auto Sampler ( I-AS), GC-ICP-MS Interface and the
ASX-500 Series ICP-MS Autosampler.
About the Maintenance Parts
It is important to maintain the Agilent 7500 regularly to extend the useful life of its
components and optimize its analytical capabilities, including the periodical
replacement of parts.
Please contact your local Agilent office when ordering parts, and please confirm the
correct part number for replacement.
P-2
Agilent 7500 Series ICP-MS Customer Maintenance Parts List
Preface
Conventions Used in This Book
This book uses certain conventions to distinguish different types of information
easily. This section describes these conventions.
Notes
Notes contain a reminder about the effect of particular actions. They are indicated as
follows:
NOT E
This example shows how a note is displayed.
Cautions
Cautions indicate situations that could overwrite data or require immediate attention
to prevent harm to the instrument. Cautions are indicated as follows:
CA UTI ON
This example shows how a caution is displayed.
Warnings
Warnings indicate situations that could cause bodily harm. Warnings are indicated as
follows:
WA RN IN G
This example shows how a warning is displayed.
P-3
Agilent 7500 Series ICP-MS Customer Maintenance Parts List
Preface
Where to Go for More Information
In addition to the Agilent 7500 Series ICP-MS Customer Maintenance Parts List,
you can reference the following resources:
Agilent 7500 Series ICP-MS ChemStation Operator's Manual
Agilent 7500 Series ICP-MS Hardware Manual
Agilent 7500 Series ICP-MS Tuning and Application Handbook
Agilent 7500 Series ICP-MS Option Instruction Manual
Online Help
Integrated Autosampler Manual
GC-ICP-MS Interface Manual
Your computer system has additional manuals that document the software and
hardware. For more information on using or maintaining your computer, printer, or
peripheral equipment, consult the respective hardware users guide. Microsoft
Windows has a users guide that explains how to install, use, and troubleshoot the
software.
Agilent Technologies on the Internet
You can get information about applications, peripherals and the core products at
www.agilent.com/chem/icpms. The patch file to update the ChemStation to the
latest revision can also be downloaded from the same URL.
Notice of Trademarks
Tygon and PharMed are registered trademarks of Norton Performance Plastics
Corporation.
Teflon is a registered trademark of E. I. DuPont de Nemours and Company.
Viton is a registered trademark of DuPont Dow Elastomers, L.L.C.
P-4
Parts Related to the Peristaltic Pump
Agilent 7500 Series ICP-MS Customer Maintenance Parts List
Parts Related to the Peristaltic Pump
Parts Related to the Peristaltic Pump
Peristaltic Pump Tubing for Sample Introduction
(Tygon Tubing, 1.02mm id, 12/pk)
P/N : G1833-65569
This tubing is the standard peristaltic pump tubing for sample
introduction. It can be used for introducing many sample types
such as nitric acid and hydrofluoric acid, but cannot be used
for introducing organic solvents.
Peristaltic Pump Tubing for Drainage
(PharMed Tubing, 1.52mm id, 12/pk)
P/N : G1833-65570
This tubing is the standard peristaltic pump tubing for
drainage. It has a long lifetime, but cannot be used for sample
introduction because its impurity level is high.
This tubing has stronger stoppers than the existing tubing
(G1820-65216). This tubing is also Organic resistant.
Peristaltic Pump Tubing for ISTD
(Tygon Tubing, 0.19mm id, 12/pk)
P/N : G1833-65571
This tubing is used for online internal standard addition.
1-2
Agilent 7500 Series ICP-MS Customer Maintenance Parts List
Parts Related to the Peristaltic Pump
Online ISTD Addition Kit
P/N : G1833-65071
The online ISTD (internal standard) addition kit allows mixing
of the sample solution with the internal standard solution at a
fixed rate using the peristaltic pump.
When Internal Standard is not used, install the Plug for the
cross joint into the cross joint.
)
)
6'(.1067$+0)
27/267$+0)
61+56&
)
6'(.1067$+0)
)
615#/2.'
27/2
610'$7.+<'4
)
6'(.1067$+0)
6'(.1067$+0)
Table 1-1
)
)
Kit Contents
Description
QTY P/N in drawing
P/N for Ordering
Peristaltic Pump Tubing 2
5042-0918
G1833-65571
Tubing Adapter
G3138-60041
G3138-65158
Sample Tubing
G1820-65478
G1820-65478
Plug for Cross Joint
5042-4749
G3138-65129
Sample Tubing
G1820-65009
G1820-65009
Teflon Nut
5042-4728
5064-8023
Front and Back Ferrule 5
5042-4729
5064-8024
Cross Joint
G1833-60299
G1833-65579*
* for H2O2 Sample : G1833-65580
1-3
Agilent 7500 Series ICP-MS Customer Maintenance Parts List
Parts Related to the Peristaltic Pump
Bushing
Connector for Spray
Chamber Drainage
Tubing
Drain Tubing Kit
P/N : G1833-65411
This tubing kit is used to drain the spray chamber to waste.
Use the bushing for organic solvent (G1820-65504) when
organic solvent is introduced.
Description :
Connector for Spray Chamber Drainage
Bushing (Viton O-ring)
Tubing (4.0mm id, 120mm)
Connector
Connector
Connector for Spray Chamber Drainage
(Polypropylene)
P/N : G1820-65503
Bushing
P/N : G1820-65482, Viton, 5/pk
G1820-65504, for Organic Solvent, 1/pk
Tubing for Drainage (4.0mm id, 2.5m)
P/N : G1820-65515, Organic resistant
Drain Tank
P/N : 5042-4769 (4 liter)
G1820-65016 (1 liter)
G1820-65505 (for Organic Solvent)
5042-4769 : Polyethelene
G1820-65016 : with Polyvinyl Chloride Connector
G1820-65505 : with Polypropylene Connector
Photo : 5042-4769
1-4
Agilent 7500 Series ICP-MS Customer Maintenance Parts List
Parts Related to the Peristaltic Pump
Tubing Cutter
P/N : 8710-1930
1-5
Agilent 7500 Series ICP-MS Customer Maintenance Parts List
Parts Related to the Peristaltic Pump
1-6
Parts Related to the Nebulizer
Agilent 7500 Series ICP-MS Customer Maintenance Parts List
Parts Related to the Nebulizer
Parts for the Babington Nebulizer
Babington Nebulizer
(with Viton O-ring and Sample Tubing, PEEK)
P/N : G1820-60453
The Babington nebulizer can be used for introducing samples
with high matrix and high TDS (total dissolved salts) level
samples.
Parts required for Babington Nebulizer
End Cap for Babington Nebulizer
(with Viton O-ring, Polypropylene)
P/N : G1833-65476
Carrier Gas Line Connector for Babington Nebulizer
(with ferrule and Viton O-ring, Teflon)
P/N : G1820-65214
The port with the o-ring connects with the nebulizer, and the
port with the ferrule connects with the carrier gas line tubing.
2-2
Agilent 7500 Series ICP-MS Customer Maintenance Parts List
Parts Related to the Nebulizer
Sample Tubing with Connector for Babington
Nebulizer (Teflon)
P/N : G1820-65276
This tool is used for removing and installing the sample tubing
into the Babington nebulizer.
Babington Nebulizer Removal Tool
P/N : G1820-65345
This tool is used to remove the Babington nebulizer from the
end cap.
O-rings for Babington Nebulizer (Viton O-rings, 4/pk)
P/N : G1820-65199
Ferrule and Viton O-ring Kit for Carrier Gas Line
Connector for Babington/Concentric Nebulizer
P/N : G1820-65533
Tunbing for Make-up Gas
End Cap
Nebulizer
Tubing for
Carrier Gas
Figure: Babington Nebulizer and Connector, End Cap
2-3
Agilent 7500 Series ICP-MS Customer Maintenance Parts List
Parts Related to the Nebulizer
Parts for the Concentric Nebulizer
Concentric Nebulizer (Quartz)
P/N : G1820-65138
This nebulizer is recommended for trace analysis and
introducing organic solvents. The inner capillary can be
clogged from particles or high concentrations of salt.
Concentric Nebulizer (Pyrex)
P/N : G1820-65030
Parts required for Concentric Nebulizer
End Cap for Concentric Nebulizer
(with Viton O-rings, PTFE)
P/N : G1833-65475
Carrier Gas Line Connector for Concentric Nebulizer
(with ferrule and Viton O-ring, Teflon)
P/N : G1820-65052
The port with the o-ring connects with the nebulizer, and the
port with the ferrule connects with the carrier gas line tubing.
Sample Line Connector for Concentric Nebulizer
(with Viton O-ring)
P/N : G1820-60160
The port with the larger hole connects with the nebulizer, and
the port with the smaller hole connects with the sample line
tubing.
2-4
Agilent 7500 Series ICP-MS Customer Maintenance Parts List
Parts Related to the Nebulizer
O-ring Kit for Concentric Nebulizer
(Viton O-rings, 2 types, 10ea.)
P/N : G1820-65491
O-ring kit
P/N: G1820-65075
Viton o-rings, 2 sizes, 2 ea.
These o-rings are used for the end cap for the concentric
nebulizer. The smaller o-rings seal between the concentric
nebulizer and the center hole of the end cap, and the larger
o-rings seal between the end cap and spray chamber.
Replacement is required when the o-ring is damaged and
the seal is no longer good.
Tubing for
Make-up Gas
Tubing for
Carrier Gas
End Cap
Nebulizer
Teflon Tubing
for Sample
Figure: Concentric Nebulizer and Connector, End Cap
2-5
Agilent 7500 Series ICP-MS Customer Maintenance Parts List
Parts Related to the Nebulizer
Parts for the Micro Flow Nebulizers
Agilent Micro Flow Nebulizer
P/N : G3139A#011 MFN100 (100-200l/min)
G3139A#012 MFN20 (20-40l/min)
G3139A#021 MFN100 for I-AS (100-200l/min)
G3139A#022 MFN20 for I-AS (20-40l/min)
G3139A#131 MFN100 for ASX-500
(100-200l/min)
( ) approximate flow rate.
This is an all fluoropolymer, low-flow, reliable nebulizer. This
nebulizer is used for many sample types including low volume
samples, aggressive chemicals and solvent, organic solvent,
etc. This nebulizer can be used with G3139A#301. It can be
also used with the concentric end cap (G1833-65475) and
Spray Chamber (G1820-65337 or G1833-65463).
HF Kit for the Micro Flow Nebulizer
P/N : G3139A#301
Contents
G3139-65002 End Cap
G3139-65003 Spray Chamber
G3139-65004 Connector
G3139-65006 Inert Torch (without Injector, Quartz)
G3139-65005 Injector for Inert Torch, Platinum, 2.0mm id
End Cap for the Agilent Micro Flow Nebulizer
P/N : G3139-65002
This is an End Cap for the Agilent Micro Flow Nebulizer.
O-rings are not required to seal the connection to the Spray
Chamber.
2-6
Agilent 7500 Series ICP-MS Customer Maintenance Parts List
Parts Related to the Nebulizer
Spray Chamber for Agilent Micro Flow Nebulizer
(PFA)
P/N : G3139-65003
This PFA spray chamber is the standard spray chamber for the
inert sample introduction kit, and is used when aspirating
hydrofluoric acid.
Connector for Agilent Micro Flow Nebulizer
P/N : G3139-65004
This connector is used to connect the PFA spray chamber to
the torch and is used when aspirating hydrofluoric acid.
O-rings are not required to seal the connection between the
spray chamber and the injector of the inert torch.
Inert Torch (without Injector, Quartz) for the Agilent
Micro Flow Nebulizer
P/N : G3139-65006
This torch is used with a platinum injector for the inert torch
assembly. The inert torch assembly is used when aspirating
hydrofluoric acid.
Injector of Inert Torch for the Agilent Micro Flow
Nebulizer
P/N : G3139-65005
This injector is used with the inert torch assembly. The inert
torch assembly is used when aspirating hydrofluoric acid.
Union for Carrier Gas Line (2/pk)
P/N: G1833-65583
2-7
Agilent 7500 Series ICP-MS Customer Maintenance Parts List
Parts Related to the Nebulizer
Parts for the MicroMist Nebulizer
MicroMist Nebulizer
P/N: G3266A#001
Contents
MicroMist Nebulizer
EzyLok Connector
This must be used with the concentric End Cap
(G1833-65475)
Sample Tubing for the MicroMist Nebulizer
(700mm, with Connector, 10/pk)
P/N: G3266-80010, 0.25mm id
G3266-80011, 0.5mm id
EzyLok Connector
P/N: G3266-80015
2-8
Agilent 7500 Series ICP-MS Customer Maintenance Parts List
Parts Related to the Nebulizer
Burgener Research Mira Mist Nebulizer
Burgener Research Mira Mist Nebulizer
P/N : G3161A#001 Teflon
P/N : G3161A#002 PEEK
Photo: Mira Mist Nebulizer Teflon
This nebulizer is for Environmental samples. It must be used
with the concentric End Cap (G1833-65475) and Spray
Chamber (G1820-65337 or G1833-65463).
2-9
Agilent 7500 Series ICP-MS Customer Maintenance Parts List
Parts Related to the Nebulizer
Parts Related to the PFA Concentric Nebulizer
PFA Concentric Nebulizer (made of PFA)
P/N: G3285-80000 (200 L/min)
G3285-80001 (200 L/min, with I-AS probe
attachment)
A low flow nebulizer made of 100% fluorocarbon resin. This
nebulizer has high stability and can be used with various acids,
alkali samples and organic solvents. Inert Sample Introduction
Kit also available (G3285-80010, G3285-80011, G3285-80012
and G3285-80013). End cap can also be used with the
concentric nebulizer (G1833-65475).
Union Connector (tube diameter 4.0 mm)
P/N: 5064-8078
Used to connect the carrier gas tube to the PFA concentric
nebulizer.
Inert Sample Introduction Kit
P/N: G3285A#101 (2.5 mm id Sapphire injector)
G3285A#102 (2.5 mm id Platinum injector)
G3285A#103 (1.5 mm id Sapphire injector)
G3285A#104 (1.5 mm id Platinum injector)
Kit components:
End cap
Spray chamber
Drain tube
Connector tube
Injector
Torch
Bracket
The 1.5 mm injector comes with a port for option gas which
can be used for oxygen gas when using organic solvent.
For Agilent 7500 with serial number JP51201712 or before, it
is necessary to change to the new bracket which is provided.
2-10
Agilent 7500 Series ICP-MS Customer Maintenance Parts List
Parts Related to the Nebulizer
Order numbers for the components of the Inert Sample
Introduction Kit are as follows.
Torch
Spray Chamber Injector
End Cap (PFA)
P/N: G3285-80020
Connector Tube
Drain Tube
End Cap
Spray Chamber (PFA)
P/N: G3285-80021
Drain Tube (PFA)
P/N: G3285-80022
Connector Tube (PFA)
P/N: G3285-80023
Injector (O-ring attached)
P/N: G3285-80030 (2.5 mm id Sapphire injector)
G3285-80031 (2.5 mm id Platinum injector)
G3285-80032 (1.5 mm id Sapphire injector)
G3285-80033 (1.5 mm id Platinum injector)
The 1.5 mm injector comes with a port for option gas which
can be used for oxygen gas when using organic solvent.
Torch (Quartz)
P/N: G3285-80050
2-11
Agilent 7500 Series ICP-MS Customer Maintenance Parts List
Parts Related to the Nebulizer
Parts for the Cross Flow Nebulizer
Cross Flow Nebulizer
P/N : G1833-65462
The cross flow nebulizer is the standard nebulizer for the inert
sample introduction kit, and is used for introducing
hydrofluoric acid.
Makeup Gas Line Connector for the Cross Flow
Nebulizer (Luer Type, Polypropylene)
P/N : G1833-65477
Makeup Gas Line Connector for the Cross Flow
Nebulizer (Teflon, 2/pk)
P/N : G1820-65119
The port with the ferrule connects with the makeup gas line
tubing, the other port should be firmly connected into the luer
type connector.
Sample Tube Kit for Cross Flow Nebulizer
P/N : G1820-65141
Description :
PFA Tubing for Connecting the Platinum Tubing
(0.6mm id, 1.1mm od, 150mm)
Tygon Tubing (100mm)
PFA Tubing (0.5mm id, 1.6mm od)
Cut the PFA tubing for the connection to the platinum tubing
to approx. 30mm, and connect to the end cap (insert over the
platinum tubing). Cut the other PFA tubing to the appropriate
length and connect using the Tygon tubing (see photo).
2-12
Agilent 7500 Series ICP-MS Customer Maintenance Parts List
Parts Related to the Nebulizer
Make-up Gas Line
Nebulizer
Carrier Gas Line
Sample Tube
Figure: Cross Flow Nebulizer, Fittings and Tubes
2-13
Agilent 7500 Series ICP-MS Customer Maintenance Parts List
Parts Related to the Nebulizer
Miscellaneous parts for Nebulizer
O-rings for End Cap (Viton O-rings, 5/pk)
P/N : G1820-65198
O-rings for Organic Solvents
P/N : G1820-65518, for End Cap, 2/pk
G1820-65520, for Concentric Nebulizer, 3 types,
4/pk
Connector for End Cap and Gas Line (PPS)
P/N : 5063-5263
Usage :
Connecting the Nebulizer with the Makeup Gas Line Tubing
(Babington/Concentric Nebulizer)
Connecting the Nebulizer with the Carrier Gas Line Tubing
(Cross Flow Nebulizer)
Gas Line Connector for Agilent 7500
Tubing for Carrier/Makeup Gas Line
(PTFE, 3.0mm id, 4.0mm od, 350mm, 2/pk)
P/N : G1833-65414
This tubing is used to connect the carrier/makeup gas line of
the Agilent 7500 to the nebulizer.
2-14
Agilent 7500 Series ICP-MS Customer Maintenance Parts List
Parts Related to the Nebulizer
Inner Sleeve for Carrier/Makeup/Auxiliary Gas Lines
(CTFE, 5/pk)
P/N : 5042-0922
The inner sleeve is needed to maintain a gas tight seal.
Usage :
Connecting the Nebulizer with the Carrier Gas Line Tubing
(Babington/Concentric Nebulizer)
Connecting the Nebulizer with the Makeup Gas Line Tubing
(Cross Flow Nebulizer)
Sample Tubing (PFA)
P/N : G1820-65105 0.5mm id, 1.6mm od, 5m
G1820-65009 0.5mm id, 1.6mm od, 3m
G1820-65478 0.3mm id, 1.6mm od, 3m
G1820-65478 is used for Online ISTD Addition.
Sample Tubing (PFK, 700mm, 3/pk)
P/N : G1833-65572, 0.15mm id, 1.6mm od
G1833-65573, 0.2mm id, 1.6mm od
Sample Tubing with PEEK guide
(PFA, 700mm, 5/pk)
P/N : G1820-65526, 0.15mm id, 1.6mm od
G1820-65527, 0.2mm id, 1.6mm od
G1820-65531, 0.3mm id, 1.6mm od
2-15
Agilent 7500 Series ICP-MS Customer Maintenance Parts List
Parts Related to the Nebulizer
2-16
Parts Related to the Spray Chamber
Agilent 7500 Series ICP-MS Customer Maintenance Parts List
Parts Related to the Spray Chamber
Parts Related to the Spray Chamber
Spray Chamber (Quartz)
P/N : G1820-65337
This quartz spray chamber is the standard spray chamber for
the Agilent 7500. This spray chamber should not be used with
hydrofluoric acid.
Spray Chamber (Polypropylene, Sapphire Tube)
P/N : G1833-65463
This polypropylene spray chamber is the standard spray
chamber for the inert sample introduction kit, and is used for
introducing hydrofluoric acid.
Connector (Quartz)
P/N : G1833-65426
This connector is used to connect the quartz spray chamber to
the torch.
Connector (Polypropylene)
P/N : G1833-65464
This connector is used to connect the polypropylene spray
chamber to the torch and is used for introducing hydrofluoric
acid. O-rings (G1833-65480) are also required to seal the
connection, to the spray chamber and the injector of the inert
torch.
3-2
Agilent 7500 Series ICP-MS Customer Maintenance Parts List
Parts Related to the Spray Chamber
O-ring for Polypropylene Connector
(Viton O-ring, 1/pk)
P/N : G1833-65480
This o-ring is used to connect the polypropylene connector to
the spray chamber and the injector of the inert torch.
Connector for Optional Gas Introduction (Quartz)
P/N : G1833-65427
This connector is used to mix the optional gas with the carrier
gas (e.g. oxygen gas introduction when using organic solvent).
To connect to the optional gas line, the same connector as used
for the auxiliary gas line connection is required
(G1820-65027).
Clamps (2/pk)
P/N : G1833-65430
The clamps are used to clamp the connector to the spray
chamber and torch.
3-3
Agilent 7500 Series ICP-MS Customer Maintenance Parts List
Parts Related to the Spray Chamber
3-4
Parts Related to the Torch
Agilent 7500 Series ICP-MS Customer Maintenance Parts List
Parts Related to the Torch
Parts Related to the Torch
Torch (Quartz)
P/N : G1833-65423, 2.5mm id
G1833-65424, 1.5mm id, Taper Type
G1833-65425, 1.0mm id, Taper Type
Photo : G1833-65423
The torch (2.5mm id) is the standard torch for the Agilent
7500. The torch (taper type) is used for introducing organic
solvent, etc. These torches cannot be used for introducing
hydrofluoric acid.
Inert Torch (without Injector, Quartz)
P/N : G1833-65422
This torch is used with the platinum or sapphire injector for the
inert torch assembly. The inert torch assembly is used for
introducing hydrofluoric acid.
Injector for Inert Torch
P/N : G1833-65409, Platinum, 2.0mm id
G1833-65415, Platinum, 2.5mm id
G1833-65416, Platinum, 1.5mm id
G1833-65410, Sapphire, 2.0mm id
Photo : G1833-65409
This injector is used with the inert torch for the inert torch
assembly. The inert torch assembly is used for introducing
hydrofluoric acid.
4-2
Agilent 7500 Series ICP-MS Customer Maintenance Parts List
Parts Related to the Torch
Long Life Shield Plate
P/N : G1833-65419
This shield plate uses different materials that extend the
operational lifetime.
Bonnet (Quartz Ring for Shield Torch)
P/N : G1833-65421
Work Coil
P/N : G1833-65432
Tubing for the Plasma/Auxiliary Gas Line
(Polyurethane)
P/N : G3270-65021
These tubes are used to connect the plasma gas and auxiliary
gas lines to the torch.
Description :
Tubing for Plasma Gas Line (Tubing, 4mm id, 350mm)
Tubing for Auxiliary Gas Line ( Tubing, 2.5mm id, 350mm)
Connector for Plasma/Auxiliary Gas
(Body : PTFE, Nut : ECTFE, 1/pk each)
P/N : G1820-65027
These connectors are used to connect the plasma gas and
auxiliary gas lines to the torch.
4-3
Agilent 7500 Series ICP-MS Customer Maintenance Parts List
Parts Related to the Torch
Inner Sleeve (CTFE)
P/N : 5042-0922, for Carrier/Makeup/Auxiliary Gas
Lines, 5/pk
5042-0923, for Plasma Gas Line, 5/pk
The inner sleeve is needed to maintain a gas tight seal.
4-4
Parts Related to the Interface
Agilent 7500 Series ICP-MS Customer Maintenance Parts List
Parts Related to the Interface
Parts Related to the Interface
Interface and Skimmer Base Conformity Chart
Part number
Specifications
7500a
7500i
7500s
7500c
7500ce
7500cs
T-mode
Nickel
G1820-65239
Platinum (10 mm insert)
G1820-65360
Platinum (18 mm insert)
G1820-65480
Nickel, for T-mode
T-mode
T-mode
T-mode
Sampling cone
G1820-65238
Skimmer cone
G1820-65050
Nickel
G1833-65497
Nickel
G3270-65024
Nickel
G1820-65237
Base: Copper, Tip: Platinum
G1833-65092
Base: Copper, Tip: Platinum
G1833-65132
Base: Copper, Tip: Platinum
G3270-60106
Base: Nickel, Tip: Platinum
G1820-65481
Nickel, for T-mode
T-mode
T-mode
T-mode
Skimmer base
G1833-65407
Stainless steel, for nickel skimmer cone
G1833-65498
Stainless steel, for nickel skimmer cone
G1833-65591
Stainless steel, for nickel skimmer cone
G1833-65408
Brass, for platinum skimmer cone
G1833-65505
Brass, for platinum skimmer cone
G1833-65590
Brass, for platinum skimmer cone
: Standard (when instrument shipped from factory) : Available part
T-mode: 7500a, 7500i, 7500s with T-mode specifications
NOT E
: Cannot be used
18mm platinum cone insert (G1820-65360) is recommended for measuring H2SO4
above 2%.
Platinum cones cannot be used for T-mode.
T-mode is not used with ORS models.
5-2
Agilent 7500 Series ICP-MS Customer Maintenance Parts List
Parts Related to the Interface
Sampling Cone with O-ring
P/N : G1820-65238, Ni Sampling Cone
G1820-65239, Pt Sampling Cone (10mm Insert)
G1820-65360, Pt Sampling Cone (18mm Insert)
G1820-65480, Ni Sampling Cone
Photo : G1820-65238
Application must refer to Interface and Skimmer Base
Conformity Chart.
G1820-65238 :
The Nickel sampling cone is used as the standard interface of
the Agilent 7500a, i, c, ce. This sampling cone is relatively
robust to samples containing high concentrations of matrix and
salts, and is suitable for a wide variety of samples. It is usually
used with the Nickel skimmer cone.
G1820-65239 :
The Platinum sampling cone is used as the standard interface
of the Agilent 7500s, cs. It is usually used for introduction of
hydrofluoric acid and other reagents. It is usually used with
the Platinum skimmer cone.
G1820-65360 :
The Platinum sampling cone (18mm tip) is used for reagents
with high viscosity and high boiling points such as sulfuric
acid, phosphoric acid, etc. It is usually used with the Platinum
skimmer cone.
G1820-65480 :
This sampling cone is used for the T-mode option only. It is
used with the Nickel skimmer cone for T-mode.
O-ring for Sampling Cone
(Viton O-ring, Teflon Coating)
P/N : G1820-65025
5-3
Agilent 7500 Series ICP-MS Customer Maintenance Parts List
Parts Related to the Interface
Skimmer Cone
P/N : G1820-65050, Ni Skimmer Cone
G1833-65497, Ni Skimmer Cone
G3270-65024, Ni Skimmer Cone
G1820-65237, Copper base Pt Skimmer Cone
G1833-65092, Copper base Pt Skimmer Cone
G1833-65132, Copper base Pt Skimmer Cone
G3270-60106, Nickel base Pt Skimmer Cone
G1820-65481, Ni Skimmer Cone
Photo : G1820-65050
Application must refer to Interface and Skimmer Base
Conformity Chart.
G1820-65050 :
The Nickel skimmer cone is used as the standard interface of
the Agilent 7500a, i. This skimmer cone is relatively robust to
samples containing high concentrations of matrix and salts,
and is suitable for a wide variety of samples. It is usually used
with the Nickel sampling cone. It can be used with the 7500a,
7500i, and 7500s.
G1820-65237 :
The Platinum skimmer cone is usually used for introduction of
hydrofluoric acid and other reagents for the 7500s. It is usually
used with the Platinum sampling cone. It can be used with the
7500a, 7500i, and 7500s.
G1820-65481 :
This skimmer cone is used for the T-mode option only. It is
used with the Nickel sampling cone for T-mode.
G1833-65497 :
This is used for the 7500c. It is used with the Nickel sampling
cone (G1820-65238).
G3270-65024:
This Skimmer Cone is used as the standard interface for the
7500ce. It is used for the 7500ce only and it is used with the
Nickel Sampling Cone (G1820-65238).
G1833-65132 :
This Platinum skimmer cone is used as the standard interface
of the 7500cs. It can be used for the 7500ce and the 7500cs. It
is used with the Platinum sampling cone (G1820-65239 or
G1820-65360).
5-4
Agilent 7500 Series ICP-MS Customer Maintenance Parts List
Parts Related to the Interface
CA UT I ON
The Platinum Skimmer cone must be mounted on the Brass skimmer base; otherwise
the copper base of the skimmer cone will deteriorate and shorten the lifetime of the
skimmer cone itself.
Platinum Skimmer Cone
Brass Skimmer Base
7500a
G1820-65237
G1833-65408
7500ce/cs
G1833-65132
G1833-65590
Sampling Cone Removal Wrench
P/N : G1833-65405
Skimmer Cone Removal Wrench
P/N : G1833-65079
Citranox
P/N : 5188-5359
5-5
Agilent 7500 Series ICP-MS Customer Maintenance Parts List
Parts Related to the Interface
5-6
Parts Related to the Ion Lens and
Vacuum Chamber
Agilent 7500 Series ICP-MS Customer Maintenance Parts List
Parts Related to the Ion Lens and Vacuum Chamber
Parts Related to the Ion Lens and Vacuum Chamber
Interface and Skimmer Base Conformity Chart
Part number
Specifications
7500a
7500i
7500s
7500c
7500ce
7500cs
T-mode
Nickel
G1820-65239
Platinum (10 mm insert)
G1820-65360
Platinum (18 mm insert)
G1820-65480
Nickel, for T-mode
T-mode
T-mode
T-mode
Sampling cone
G1820-65238
Skimmer cone
G1820-65050
Nickel
G1833-65497
Nickel
G3270-65024
Nickel
G1820-65237
Base: Copper, Tip: Platinum
G1833-65092
Base: Copper, Tip: Platinum
G1833-65132
Base: Copper, Tip: Platinum
G3270-60106
Base: Nickel, Tip: Platinum
G1820-65481
Nickel, for T-mode
T-mode
T-mode
T-mode
Skimmer base
G1833-65407
Stainless steel, for nickel skimmer cone
G1833-65498
Stainless steel, for nickel skimmer cone
G1833-65591
Stainless steel, for nickel skimmer cone
G1833-65408
Brass, for platinum skimmer cone
G1833-65505
Brass, for platinum skimmer cone
G1833-65590
Brass, for platinum skimmer cone
: Standard (when instrument shipped from factory) : Available part
T-mode: 7500a, 7500i, 7500s with T-mode specifications
NOT E
: Cannot be used
18mm platinum cone insert (G1820-65360) is recommended for measuring H2SO4
above 2%.
Platinum cones cannot be used for T-mode.
T-mode is not used with ORS models.
6-2
Agilent 7500 Series ICP-MS Customer Maintenance Parts List
Parts Related to the Ion Lens and Vacuum Chamber
Skimmer Base with Screws
P/N : G1833-65407, Stainless Steel
G1833-65408, Brass
G1833-65498, Stainless Steel
G1833-65505, Brass
G1833-65591, Stainless Steel
G1833-65590, Brass
Photo : G1833-65407
Application must refer to Interface and Skimmer Base
Conformity Chart.
G1833-65407 :
The Stainless steel skimmer base is used as the standard
skimmer base for the Agilent 7500a. It is used to hold the
Nickel skimmer cone.
G1833-65408 :
The Brass skimmer base is used to hold the Platinum skimmer
cone.
G1833-65498 :
The Stainless steel skimmer base is used to hold the Nickel
skimmer cone for the Agilent 7500c.
G1833-65505 :
The Brass skimmer base is used to hold the Platinum skimmer
cone for the Agilent 7500c.
G1833-65591:
The Stainless steel skimmer base is used to hold the Nickel
skimmer cone for the Agilent 7500ce.
G1833-65590:
The Brass skimmer base is used to hold the Platinum skimmer
cone for the Agilent 7500cs.
Skimmer Base Screws (4/pk)
P/N : G1820-65435
6-3
Agilent 7500 Series ICP-MS Customer Maintenance Parts List
Parts Related to the Ion Lens and Vacuum Chamber
Extraction Lens 1
P/N : G1833-65417
Extraction Lens 2
P/N : G1833-65413
Extraction Lens Screw Kit
P/N : G1833-65024
Omega Lens Assembly
P/N : G1833-65418
Omega Lens Screw Kit
P/N : G1833-65025
6-4
Agilent 7500 Series ICP-MS Customer Maintenance Parts List
Parts Related to the Ion Lens and Vacuum Chamber
Plate Bias
P/N : G1833-65444 (for Slim Ring Type Quadrupole)
P/N : G1833-65494 (for Eagle Type Quadrupole)
Photo: G1833-65444
O-ring for Vacuum Chamber (Viton O-ring)
P/N : 5042-0901
O-rings for Vent Valve (Viton O-ring, 2/pk)
P/N : G1833-65332
Polishing Paper Kit (#400/#1200, 5 sheets each)
P/N : G1833-65404
The polishing paper is waterproof and is used to clean the ion
lenses and the interface cones.
6-5
Agilent 7500 Series ICP-MS Customer Maintenance Parts List
Parts Related to the Ion Lens and Vacuum Chamber
Electron Multiplier
P/N : 5184-1983 (S/N ~JP14100586)
G1833-65575 (S/N JP14100587~)
There are two types of electron multiplier: ETP and HPK.
Order P/N G1833-65575 for instruments with the label "HPK
Installed" (S/N JP14100587 and later), and P/N 5184-1983 for
instruments without such a label (S/N JP14100586 and
earlier). The two types of electron multipliers have similar
performance, but as the tuning conditions are different, using
the same type of electron multiplier is recommended.
The electron multiplier detector should be replaced when
either the Analog HV exceeds 3300v or the pulse HV exceeds
1800v.
Penning Gauge Body Tube
P/N : G1820-81012
Penning Gauge Electrode Kit
P/N : G1820-81013
6-6
Parts Related to the 7500ce
Agilent 7500 Series ICP-MS Customer Maintenance Parts List
Parts Related to the 7500ce
Parts Related to the 7500ce
Extraction Lens 1
P/N: G3270-65028
Extraction Lens 2
P/N: G3270-65029
Omega Lens-ce
P/N: G3270-65030
Omega Bias-ce
P/N: G3270-65031
7-2
Agilent 7500 Series ICP-MS Customer Maintenance Parts List
Parts Related to the 7500ce
Cell Focus Lens
P/N: G1833-65597
Cell Entrance Lens with O-ring
P/N: G1833-65598
QP Focus Lens with O-ring
P/N: G1833-65599
Cell Exit Lens
P/N: G1833-66000
7-3
Agilent 7500 Series ICP-MS Customer Maintenance Parts List
Parts Related to the 7500ce
Plate Bias
P/N : G1833-65513 (S/N JP14100050 ~ JP14100313)
G1833-65562 (S/N JP14100314 ~)
Check equipment S/N when placing an order.
Octopole (without Cell Entrance/Exit, QP Focus and
O-ring)
P/N: G1833-65133
Octopole Assembly (Cell Focus, Cell Entrance/Exit and
QP Focus, without O-ring)
P/N: G1833-65134
Reaction Cell Assembly
P/N: G1833-66001
Extraction-Omega Lens Assembly
P/N: G3270-65023
7-4
Agilent 7500 Series ICP-MS Customer Maintenance Parts List
Parts Related to the 7500ce
Extraction and Omega Lens Screw and Spacer Kit
P/N: G3270-60639
Contents:
Spacer (No lip) (QTY 2)
Spacer (lipped) (QTY 8)
Guide (lipped) (QTY 1)
Lens Screw (QTY 3)
Reaction Cell Screw and Spacer Kit
P/N: G1833-65138
Contents:
Spacer (for Cell Focus, Cell Entrance) (QTY 1)
Spacer (for QP Focus, Cell Exit) (QTY 1)
Cable for Plate Bias (QTY 1)
Cell assembly Screws (QTY 4)
Cell Entrance/Exit Lens Screws (QTY 4)
Plate Bias cable screws (QTY 2)
O-ring (2/pk)
P/N: G1833-66035
Reaction Gas Tubing (2/pk)
P/N: G1833-65089
Cotton Swabs, ultra-fine conical bud shape at both ends
(100/pk)
P/N: 9300-2574
7-5
Agilent 7500 Series ICP-MS Customer Maintenance Parts List
Parts Related to the 7500ce
Alumina Powder
P/N : 8660-0791
7-6
Parts Related to the 7500cs
Agilent 7500 Series ICP-MS Customer Maintenance Parts List
Parts Related to the 7500cs
Parts Related to the 7500cs
Extraction Lens 1
P/N: G1833-65592
Extraction Lens 2
P/N: G1833-65593
Omega Bias-cs
P/N: G1833-65594
Omega Lens-cs
P/N: G1833-65595
8-2
Agilent 7500 Series ICP-MS Customer Maintenance Parts List
Parts Related to the 7500cs
Cell Focus Lens
P/N: G1833-65597
Cell Entrance Lens with O-ring
P/N: G1833-65598
QP Focus Lens with O-ring
P/N: G1833-65599
Cell Exit Lens
P/N: G1833-66000
8-3
Agilent 7500 Series ICP-MS Customer Maintenance Parts List
Parts Related to the 7500cs
Plate Bias
P/N : G1833-65513 (S/N JP14100050 ~ JP14100313)
G1833-65562 (S/N JP14100314 ~)
Check equipment S/N when placing an order.
Octopole (Without Cell Entrance/Exit, QP Focus and
O-ring)
P/N: G1833-65133
Octopole Assembly (Cell Focus, Cell Entrance/Exit and
QP Focus, without O-ring)
P/N: G1833-65134
Reaction Cell Assembly
P/N: G1833-66001
Extraction-Omega Lens Assembly
P/N: G1833-65596
8-4
Agilent 7500 Series ICP-MS Customer Maintenance Parts List
Parts Related to the 7500cs
Extraction and Omega Lens Screw and Spacer Kit
P/N: G1833-65125
Contents:
Spacer (No lip) (QTY 2)
Spacer (Lipped) (QTY 8)
Guide (Lipped) (QTY 1)
Lens Screw (QTY 3)
Reaction Cell Screw and Spacer Kit
P/N: G1833-65138
Contents:
Spacer (for Cell Focus, Cell Entrance) (QTY 1)
Spacer (for QP Focus, Cell Exit) (QTY 1)
Cable for Plate Bias (QTY 1)
Cell assembly Screws (QTY 4)
Cell Entrance/Exit Lens Screws (QTY 4)
Plate Bias cable screws (QTY 2)
O-ring (2/pk)
P/N: G1833-66035
Reaction Gas Tubing (2/pk)
P/N: G1833-65089
Cotton Swab, ultra-fine conical bud shape at both ends
(100/pk)
P/N: 9300-2574
8-5
Agilent 7500 Series ICP-MS Customer Maintenance Parts List
Parts Related to the 7500cs
Alumina Powder
P/N : 8660-0791
8-6
Miscellaneous Components
Agilent 7500 Series ICP-MS Customer Maintenance Parts List
Miscellaneous Components
Miscellaneous Components
Plastic Tray
P/N : G1833-65412
Gas Filter
P/N : G1833-65581
Ar Gas Tubing with Filter (can be used for Option Gas
Line)
P/N : G1820-65023
Triple Filter Cartridge
P/N : 5182-9705
Replacement O-rings for Gas Filters
P/N : 5182-3423
Strainer for Cooling Water
P/N: G1833-66024
9-2
Agilent 7500 Series ICP-MS Customer Maintenance Parts List
Miscellaneous Components
Cooling Water Hose (10m)
P/N : G1833-65429
Rotary Pump Oil
P/N : 6040-0834, 1L
6040-0798, 4L
The rotary pump for the Agilent 7500 requires approx. 1L of oil.
Oil Mist Filter Kit
P/N : 3162-1056
Oil Mist Filter Element
P/N : 1535-4970
Odor Element for Oil Mist Filter (5/pk)
P/N : 5063-9153
9-3
Agilent 7500 Series ICP-MS Customer Maintenance Parts List
Miscellaneous Components
Tuning Solution
P/N : 8500-6943, Stock Tuning Solution: Li, Y, Ce and
Tl; 100 mL, 10 mg/L; matrix=2% HNO3
5184-3566, Tuning Solution: Li, Y, Ce, Tl and
Co; 2 x 500 mL, 10 g/L; matrix= 2% HNO3
5185-5959, Tuning Solution: Li, Mg, Y, Ce, Tl
and Co; 2 x 500mL, 1 g/L; matrix= 2% HNO3
LC-ICP-MS Connection Kit
P/N : G1833-65200
Description :
Sample Tubing
Ferrule
Connector
Union
APG Remote Cable
Gender Changer
APG Remote Cable (5 m)
P/N : 5064-8046
As Speciation Column
P/N : G3154-65001
Guard Column for As Speciation
P/N : G3154-65002
9-4
10
10
Parts related to the Integrated Sample
Introduction System (ISIS)
Agilent 7500 Series ICP-MS Customer Maintenance Parts List
Parts related to the Integrated Sample Introduction System (ISIS)
Parts Related to the Integrated Sample Introduction
System (ISIS)
Tubing kit
P/N : G3138-65023 Tubing kit for High throughput
P/N : G3138-65024 Tubing kit for Autodilution
P/N : G3138-65025 Tubing kit for Discrete Sampling
Tubing kit is assembled for each configuration.
Joint Holder
P/N : G3138-65102, for ICP-MS Pump
G3138-65103, for ISIS Pump
Used to hold the joints.
Sample Line Connector
P/N : G3138-65104
Valve Rotor Seal
P/N : G3138-65117
Valve Nut (6/pk)
P/N : G3138-65118
10-2
Agilent 7500 Series ICP-MS Customer Maintenance Parts List
Parts related to the Integrated Sample Introduction System (ISIS)
Valve Ferrule (6/pk)
P/N : G3138-65119
Mixer
P/N : G3138-65121
Sample Loop (100L)
P/N : G3138-65122
Tubing Adapter
P/N : G3138-65126
Between ISTD peripump tubing/teflon tubing.
Tubing Adapter
P/N : G3138-65158
Ferrule and Tubing (10/pk)
P/N : G3138-65157
10-3
Agilent 7500 Series ICP-MS Customer Maintenance Parts List
Parts related to the Integrated Sample Introduction System (ISIS)
Sample Tubing
P/N : G1820-65105, PFA, 0.5mm id, 1.6mm od, 5m
G1820-65478, PFA, 0.3mm id, 1.6mm od, 3m
5064-8016, ETFE, 0.8mm id, 1.6mm od, 5m
5064-8020, PTFE, 2.0mm id, 3.0mm od, 5m
Peristaltic Pump Tubing for ICP-MS Pump
P/N : 5064-8014
Tygon Tubing, 0.89mm id, 3 stoppers, 12/pk
5064-8034
Tygon Tubing, 0.25mm id, 3 stoppers, 12/pk
Peristaltic Pump Tubing for ISIS Pump
P/N : 5064-8015
Tygon Tubing, 0.25mm id, 2 stoppers, 12/pk
5064-8028
Tygon Tubing, 1.02mm id, 2 stoppers, 12/pk
Tee Joint
P/N : 5064-8017
Cross Joint
P/N : 5064-8018
10-4
Agilent 7500 Series ICP-MS Customer Maintenance Parts List
Parts related to the Integrated Sample Introduction System (ISIS)
Union Joint
P/N : 5064-8019
Teflon Nut (10/pk)
P/N : 5064-8021, for 3.0mm od Tubing
5064-8023, for 1.6mm od Tubing
Front and Back Ferrule
P/N : 5064-8022, for 3.0mm od Tubing
5064-8024, for 1.6mm od Tubing
Peristaltic Pump Tubing Adapter
P/N : 5064-8026
This adapter is used to connect the peristaltic pump tubing and
sample tubing. Use the appropriate nut and ferrule to connect
sample tubing.
Tubing Clamp (Small : 10/pk, Large : 5/pk)
P/N : 5064-8027
10-5
Agilent 7500 Series ICP-MS Customer Maintenance Parts List
Parts related to the Integrated Sample Introduction System (ISIS)
Spiral Tubing (5m)
P/N : 5064-8029
Valve Maintenance Wrench
P/N : 5064-8032
Tubing Identification Tag (10/pk)
P/N : 5064-8033
10-6
Agilent 7500 Series ICP-MS Customer Maintenance Parts List
Parts related to the Integrated Sample Introduction System (ISIS)
Parts Related to the Hydride Generator Accessory
Mixer
P/N : G3138-65121
Peristaltic Pump Tubing
(ismaprene, for ISIS pump, 2.54mm id, 2 stoppers,
6 pack)
P/N : G3138-65128
Cross Joint Plug (3/pk)
P/N : G3138-65129
Gas Line Tubing (PTFE, 3.0mm id, 4.0mm od, 5m)
P/N : G3138-65138
Reducing Union Connector
P/N : G3138-65139, 6mm 3mm
G3138-65140, 6mm 4mm
G3138-65144, 8mm 4mm
10-7
Agilent 7500 Series ICP-MS Customer Maintenance Parts List
Parts related to the Integrated Sample Introduction System (ISIS)
Gas/Liquid Separator Set
P/N : G3138-65130
Description :
Separator Gas Chamber
Filter O-ring
Separator Holder
Exclusive Concentric Nebulizer
Nebulizer O-ring, 2/pk
Cyclone Chamber
Filter, 5/pk
Separator Gas Chamber
P/N : G3138-65131
Filter O-ring
P/N : G3138-65132
Separator Holder
P/N : G3138-65133
Exclusive Concentric Nebulizer
P/N : G3138-65134
Nebulizer O-ring (2/pk)
P/N : G3138-65135
Cyclone Chamber
P/N : G3138-65136
Filter (10/pk)
P/N : G3138-65137
10-8
Agilent 7500 Series ICP-MS Customer Maintenance Parts List
Parts related to the Integrated Sample Introduction System (ISIS)
Plug for Carrier Gas Connector (4.0mm od, 3/pk)
P/N : G3138-65141
Y Connector (5/pk)
P/N : G3138-65143
Inner Sleeve for 3.0mm id Tubing (CTFE, 5/pk)
P/N : 5042-0922
The inner sleeve is needed to maintain a gas tight seal..
10-9
Agilent 7500 Series ICP-MS Customer Maintenance Parts List
Parts related to the Integrated Sample Introduction System (ISIS)
10-10
11
11
Parts Related to the GC-ICP-MS
Interface
Agilent 7500 Series ICP-MS Customer Maintenance Parts List
Parts Related to the GC-ICP-MS Interface
Parts Related to the GC-ICP-MS Interface
Transfer Line
P/N : G3158-65000
Injector
P/N : G3158-65001
Stainless Steel Pipe (1/16in, with connector)
P/N : G3158-65002
Silico Steel Pipe (1/16in)
P/N : G3158-65003
11-2
Agilent 7500 Series ICP-MS Customer Maintenance Parts List
Parts Related to the GC-ICP-MS Interface
Ferrule Kit
P/N : G3158-65004
Description:
Reducer Ferrule (1/8in to 1/16in, 2/pk)
Graphite Ferrule (320um, 0.5mm id, 2/pk)
Vespel-Graphite Ferrule (1/4in, 2/pk)
Vespel-Graphite Ferrule (1/16in, 2/pk)
Graphite Ferrule (320um, 0.5mm id, 10/pk)
P/N : G3158-65005
Xe Gas Mixture Tee Union
P/N : G3158-65006
Torch for GC-ICP-MS Interface
P/N : G3158-65007
Alignment Boss
P/N : G3158-65008
11-3
Agilent 7500 Series ICP-MS Customer Maintenance Parts List
Parts Related to the GC-ICP-MS Interface
11-4
12
12
Parts Related to the Integrated Auto
Sampler (I-AS)
Agilent 7500 Series ICP-MS Customer Maintenance Parts List
Parts Related to the Integrated Auto Sampler (I-AS)
Parts Related to the I-AS (Integrated Auto Sampler)
Tray, Vial Set
P/N : G3160-65300 (Type A Tray, includes 200 6mL
vials)
G3160-65301 (Type B Tray, includes 55 18mL
vials)
G3160-65302 (Type C Tray, includes 20 50mL
vials)
G3160-65308 (Type D Tray, includes 200 2mL
vials and 10 18mL vials)
G3160-65309 (Type E Tray, includes 200 6mL
vials and 10 18mL vials)
Type A Tray : 89 positions for 6mL vials
Type B Tray : 53 positions for 18mL vials
Type C Tray : 8 positions for 50mL vials
Type D Tray : 79 positions for 2mL vials + 10 positions for
18mL vials
Type E Tray : 79 positions for 6mL vials + 10 positions for
18mL vials
Tray
P/N : G3160-65310, Type A Tray
G3160-65311, Type B Tray
G3160-65312, Type C Tray
G3160-65313, Type D Tray
G3160-65314, Type E Tray
Photo : G3160-65310
G3160-65310
Type A Tray-89 position for 6mL vial
G3160-65311
Type B Tray-53 position for 18mL Vial
12-2
Agilent 7500 Series ICP-MS Customer Maintenance Parts List
Parts Related to the Integrated Auto Sampler (I-AS)
G3160-65312
Type C Tray-18 position for 50mL Vial
G3160-65313
Type D Tray - 79 position for 2mL (or 1.5mL) vial and 10
position for 18mL vial
G3160-65314
Type E Tray - 79 position for 6mL vial and 10 position for
18mL vial
Vial
P/N : G3160-65303
6mL vial (Polypropylene), 200 pieces
P/N : G3160-65304
18mL vial (Polypropylene), 55 pieces
P/N : G3160-65305
50mL vial (Polypropylene), 20 pieces
P/N : G3160-65315
2mL vial (Polyethylene), 200 pieces
P/N : G3160-65317
1.5mL vial (PFA), 10 pieces
G3160-65303
for type A, E Tray
G3160-65304
for type B, D, E, Tray
G3160-65305
for type C Tray
G3160-65315
for type D Tray
G3160-65317
for type D Tray
12-3
Agilent 7500 Series ICP-MS Customer Maintenance Parts List
Parts Related to the Integrated Auto Sampler (I-AS)
Probe
P/N : G3160-65306 (0.3mm id)
G3160-65324 (0.8mm id)
Tray Cover
P/N : G3160-65321
Rinse Fluid Inlet/Outlet Tube
P/N : G3160-65320
External Bottle
P/N : G3160-65307
100mL Bottles (with cap (QTY3), with holed cap (QTY3))
12-4
Agilent 7500 Series ICP-MS Customer Maintenance Parts List
Parts Related to the Integrated Auto Sampler (I-AS)
Peristaltic Pump Tubing Set (With Connectors)
P/N : G3160-65326 (1 Set)
G3160-65327 (5 Set)
Peristaltic Pump Tubing for I-AS
Rinse Tubing (Tygon)
P/N : G3160-65328 (2 Pieces)
Tubing for Peristaltic Pump Tubing to Rinse Bottle and
Peristaltic Pump tubing to Drain Bottle.
TubeHolder(forI-AS)
P/N: G3160-65325
Use this adapter for connecting the 1.66mm sample tubing
to the probe.
It is possible to use the sample tubes G1833-65572
(0.15mmid), G1833-65573 (0.2mmid), G1820-65478
(0.3mm id).
Needle Holder
P/N : G3160-80041
Arm
P/N : G3160-80044
Carry Holder for tray and tray cover
P/N : G3160-60015
Convenient holder for lifting and carrying the I-AS tray in
combination with the tray cover.
12-5
Agilent 7500 Series ICP-MS Customer Maintenance Parts List
Parts Related to the Integrated Auto Sampler (I-AS)
12-6
13
13
Parts Related to the ASX-500 Series
ICP-MS Autosampler
Agilent 7500 Series ICP-MS Customer Maintenance Parts List
Parts Related to the ASX-500 Series ICP-MS Autosampler
Parts Related to the Agilent ASX-500 Series ICP-MS
Autosampler
Sample Rack
P/N : G3286-80103 (21 positions, for 50 mL vials)
G3286-80104 (24 positions, for 30 mL vials)
G3286-80105 (40 positions, for 20 mL vials)
G3286-80106 (60 positions, for 14 mL vials)
G3286-80107 (90 positions, for 8 mL vials)
Sample Probe
P/N : G3286-80100 (0.8 mm id)
G3286-80101 (0.3 mm id)
G3286-80102 (0.5 mm id)
Rinse/Drain Tubing Hookup Kit
P/N : G3286-80117
PeriPump (drain) Tubing and Connector Kit (Tygon)
P/N : G3286-80118
13-2
Agilent 7500 Series ICP-MS Customer Maintenance Parts List
Parts Related to the ASX-500 Series ICP-MS Autosampler
Z-Axis Drive Assembly
P/N : G3286-80200
Rinse Station
P/N : G3286-80224
13-3
Agilent 7500 Series ICP-MS Customer Maintenance Parts List
Parts Related to the ASX-500 Series ICP-MS Autosampler
13-4
INDEX
1535-4970 ............................... 9-3
3162-1056 ............................... 9-3
5042-0901 ............................... 6-5
5042-0922 ............. 2-15, 4-4, 10-9
5042-0923 ............................... 4-4
5042-4769 ............................... 1-4
5063-5263 ............................. 2-14
5063-9153 ............................... 9-3
5064-8014 ............................. 10-4
5064-8015 ............................. 10-4
5064-8016 ............................. 10-4
5064-8017 ............................. 10-4
5064-8018 ............................. 10-4
5064-8019 ............................. 10-5
5064-8020 ............................. 10-4
5064-8021 ............................. 10-5
5064-8022 ............................. 10-5
5064-8023 ............................. 10-5
5064-8024 ............................. 10-5
5064-8026 ............................. 10-5
5064-8027 ............................. 10-5
5064-8028 ............................. 10-4
5064-8029 ............................. 10-6
5064-8032 ............................. 10-6
5064-8033 ............................. 10-6
5064-8034 ............................. 10-4
5064-8046 ............................... 9-4
5064-8078 ............................. 2-10
5182-3423 ............................... 9-2
5182-9705 ............................... 9-2
5184-1983 ............................... 6-6
5184-3566 ............................... 9-4
5185-5959 ............................... 9-4
5188-5359 ............................... 5-5
6040-0798 ............................... 9-3
6040-0834 ............................... 9-3
8500-6943 ............................... 9-4
8660-0791 ........................ 7-6, 8-6
8710-1930................................ 1-5
9300-2574......................... 7-5, 8-5
G1820-60160........................... 2-4
G1820-60453........................... 2-2
G1820-65009......................... 2-15
G1820-65016........................... 1-4
G1820-65023........................... 9-2
G1820-65025........................... 5-3
G1820-65027........................... 4-3
G1820-65030........................... 2-4
G1820-65050........................... 5-4
G1820-65052........................... 2-4
G1820-65075........................... 2-5
G1820-65105................ 2-15, 10-4
G1820-65119......................... 2-12
G1820-65138........................... 2-4
G1820-65141......................... 2-12
G1820-65198......................... 2-14
G1820-65199........................... 2-3
G1820-65214........................... 2-2
G1820-65237........................... 5-4
G1820-65238........................... 5-3
G1820-65239........................... 5-3
G1820-65276........................... 2-3
G1820-65337........................... 3-2
G1820-65345........................... 2-3
G1820-65360........................... 5-3
G1820-65435........................... 6-3
G1820-65478................ 2-15, 10-4
G1820-65480........................... 5-3
G1820-65481........................... 5-4
G1820-65482........................... 1-4
G1820-65491........................... 2-5
G1820-65503........................... 1-4
G1820-65504........................... 1-4
G1820-65505........................... 1-4
G1820-65515........................... 1-4
G1820-65518......................... 2-14
I-1
Agilent 7500 Series ICP-MS Customer Maintenance Parts List
INDEX
G1820-65520 ........................ 2-14
G1820-65526 ........................ 2-15
G1820-65527 ........................ 2-15
G1820-65531 ........................ 2-15
G1820-65533 .......................... 2-3
G1820-81012 .......................... 6-6
G1820-81013 .......................... 6-6
G1833-65024 .......................... 6-4
G1833-65025 .......................... 6-4
G1833-65071 .......................... 1-3
G1833-65079 .......................... 5-5
G1833-65089 ................... 7-5, 8-5
G1833-65092 .......................... 5-4
G1833-65125 .......................... 8-5
G1833-65132 .......................... 5-4
G1833-65133 ................... 7-4, 8-4
G1833-65134 ................... 7-4, 8-4
G1833-65138 ................... 7-5, 8-5
G1833-65200 .......................... 9-4
G1833-65332 .......................... 6-5
G1833-65404 .......................... 6-5
G1833-65405 .......................... 5-5
G1833-65407 .......................... 6-3
G1833-65408 .......................... 6-3
G1833-65409 .......................... 4-2
G1833-65410 .......................... 4-2
G1833-65411 .......................... 1-4
G1833-65412 .......................... 9-2
G1833-65413 .......................... 6-4
G1833-65414 ........................ 2-14
G1833-65415 .......................... 4-2
G1833-65416 .......................... 4-2
G1833-65417 .......................... 6-4
G1833-65418 .......................... 6-4
G1833-65419 .......................... 4-3
G1833-65421 .......................... 4-3
G1833-65422 .......................... 4-2
G1833-65423 .......................... 4-2
I-2
G1833-65424 .......................... 4-2
G1833-65425 .......................... 4-2
G1833-65426 .......................... 3-2
G1833-65427 .......................... 3-3
G1833-65429 .......................... 9-3
G1833-65430 .......................... 3-3
G1833-65432 .......................... 4-3
G1833-65444 .......................... 6-5
G1833-65462 ........................ 2-12
G1833-65463 .......................... 3-2
G1833-65464 .......................... 3-2
G1833-65475 .......................... 2-4
G1833-65476 .......................... 2-2
G1833-65477 ........................ 2-12
G1833-65480 .......................... 3-3
G1833-65494 .......................... 6-5
G1833-65497 .......................... 5-4
G1833-65498 .......................... 6-3
G1833-65505 .......................... 6-3
G1833-65513 ................... 7-4, 8-4
G1833-65562 ................... 7-4, 8-4
G1833-65569 .......................... 1-2
G1833-65570 .......................... 1-2
G1833-65571 .......................... 1-2
G1833-65572 ........................ 2-15
G1833-65573 ........................ 2-15
G1833-65575 .......................... 6-6
G1833-65581 .......................... 9-2
G1833-65583 .......................... 2-7
G1833-65590 .......................... 6-3
G1833-65591 .......................... 6-3
G1833-65592 .......................... 8-2
G1833-65593 .......................... 8-2
G1833-65594 .......................... 8-2
G1833-65595 .......................... 8-2
G1833-65596 .......................... 8-4
G1833-65597 ................... 7-3, 8-3
G1833-65598 ................... 7-3, 8-3
Agilent 7500 Series ICP-MS Customer Maintenance Parts List
INDEX
G1833-65599.................... 7-3, 8-3
G1833-66000.................... 7-3, 8-3
G1833-66001.................... 7-4, 8-4
G1833-66024........................... 9-2
G1833-66035.................... 7-5, 8-5
G3138-65023......................... 10-2
G3138-65024......................... 10-2
G3138-65025......................... 10-2
G3138-65102......................... 10-2
G3138-65103......................... 10-2
G3138-65104......................... 10-2
G3138-65117......................... 10-2
G3138-65118......................... 10-2
G3138-65119......................... 10-3
G3138-65121................ 10-3, 10-7
G3138-65122......................... 10-3
G3138-65126......................... 10-3
G3138-65128......................... 10-7
G3138-65129......................... 10-7
G3138-65130......................... 10-8
G3138-65131......................... 10-8
G3138-65132......................... 10-8
G3138-65133......................... 10-8
G3138-65134......................... 10-8
G3138-65135......................... 10-8
G3138-65136......................... 10-8
G3138-65137......................... 10-8
G3138-65138......................... 10-7
G3138-65139......................... 10-7
G3138-65140......................... 10-7
G3138-65141......................... 10-9
G3138-65143......................... 10-9
G3138-65144......................... 10-7
G3138-65157......................... 10-3
G3138-65158......................... 10-3
G3139-65002........................... 2-6
G3139-65003........................... 2-7
G3139-65004........................... 2-7
G3139-65005........................... 2-7
G3139-65006........................... 2-7
G3139A#011............................ 2-6
G3139A#012............................ 2-6
G3139A#021............................ 2-6
G3139A#022............................ 2-6
G3139A#131............................ 2-6
G3139A#301............................ 2-6
G3154-65001........................... 9-4
G3154-65002........................... 9-4
G3158-65000......................... 11-2
G3158-65001......................... 11-2
G3158-65002......................... 11-2
G3158-65003......................... 11-2
G3158-65004......................... 11-3
G3158-65005......................... 11-3
G3158-65006......................... 11-3
G3158-65007......................... 11-3
G3158-65008......................... 11-3
G3160-60015......................... 12-5
G3160-65300......................... 12-2
G3160-65301......................... 12-2
G3160-65302......................... 12-2
G3160-65303......................... 12-3
G3160-65304......................... 12-3
G3160-65305......................... 12-3
G3160-65306......................... 12-4
G3160-65307......................... 12-4
G3160-65308......................... 12-2
G3160-65309......................... 12-2
G3160-65310......................... 12-2
G3160-65311......................... 12-2
G3160-65312......................... 12-2
G3160-65313......................... 12-2
G3160-65314......................... 12-2
G3160-65315......................... 12-3
G3160-65317......................... 12-3
G3160-65320......................... 12-4
I-3
Agilent 7500 Series ICP-MS Customer Maintenance Parts List
INDEX
G3160-65321 ........................ 12-4
G3160-65324 ........................ 12-4
G3160-65325 ........................ 12-5
G3160-65326 ........................ 12-5
G3160-65327 ........................ 12-5
G3160-65328 ........................ 12-5
G3160-80041 ........................ 12-5
G3160-80044 ........................ 12-5
G3161A#001 ........................... 2-9
G3161A#002 ........................... 2-9
G3266-80010 .......................... 2-8
G3266-80011 .......................... 2-8
G3266-80015 .......................... 2-8
G3266A#001 ........................... 2-8
G3270-60106 .......................... 5-4
G3270-60639 .......................... 7-5
G3270-65021 .......................... 4-3
G3270-65023 .......................... 7-4
G3270-65024 .......................... 5-4
G3270-65028 .......................... 7-2
G3270-65029 .......................... 7-2
G3270-65030 .......................... 7-2
G3270-65031 .......................... 7-2
G3285-80000 ........................ 2-10
G3285-80001 ........................ 2-10
G3285-80020 ........................ 2-11
G3285-80021 ........................ 2-11
G3285-80022 ........................ 2-11
G3285-80023 ........................ 2-11
G3285-80030 ........................ 2-11
G3285-80031 ........................ 2-11
G3285-80032 ........................ 2-11
G3285-80033 ........................ 2-11
G3285-80050 ........................ 2-11
G3285A#101 ......................... 2-10
G3285A#102 ......................... 2-10
G3285A#103 ......................... 2-10
G3285A#104 ......................... 2-10
I-4
G3286-80100 ........................
G3286-80101 ........................
G3286-80102 ........................
G3286-80103 ........................
G3286-80104 ........................
G3286-80105 ........................
G3286-80106 ........................
G3286-80107 ........................
G3286-80117 ........................
G3286-80118 ........................
G3286-80200 ........................
G3286-80224 ........................
13-2
13-2
13-2
13-2
13-2
13-2
13-2
13-2
13-2
13-2
13-3
13-3