BHEL Haridwar 5.
1-0690-02/1
Steam Turbine Lubrication Chart
Description
No. Lubrication
Point
Filling
Quantity
Lubricant Lubrication
Interval
Top-up
Quantity
Remarks
1 Overspeed test
device
Turbine oil* Every 1 to 2
months
2 Reduction gear of
overspeed trip
test device
200g Grease
Servogem-2
Every 1 to 2
months
10g
3 Bearing of low
vacuum trip
Turbine oil* Every 1 to 2
months
4 Main control valve
stem
Molykote U After every
dismantling
Use no oil
or grease
5 Main stop valve
stem
Molykote U After every
dismantling
Use no oil
or grease
6 Limit Switch
attachment on
main stop valve
Molykote
M30
Every 1 to 2
months
Use no oil
or grease
7 Limit Switch
attachment on
main control valve
Molykote
M30
Every 1 to 2
months
Use no oil
or grease
8 Hinge of main
control valve
position indicator
Molykote
M30
Every 1 to 2
months
Use no oil
or grease
9 LAWA actuator
VR 16 of main
control valve
0.4 kg Calypsol
SF7-026
Every 10
4
Operating
hours
0.4 kg
10 Reheat control
valve stem
Molykote U After every
dismantling
Use no oil
or grease
11 Reheat stop valve
stem
Molykote U After every
dismantling
Use no oil
or grease
12 Limit switch
attachment on
reheat stop valve
Molykote
M30
Every 1 to 2
months
Use no oil
or grease
13 LAWA actuator
VR 16 of reheat
control valve
0.4 kg Calypsol
SF7-026
Every 10
4
Operating
hours
0.4 kg
14 Hinge of reheat
control valve
position indicator
Molykote
M30
Every 1 to 2
months
Use no oil
or grease
15 Limit switch
attachment on
reheat control
valve
Molykote
M30
Every 1 to 2
months
Use no oil
or grease
16 Hinge of
extraction swing
check valve
Molykote U After every
dismantling
Use no oil
or grease
17 Adjusting gear of
starting and load
limit device
200g Grease
Servogem-2
Every 1 to 2
months
10g
5.1-0690-02/2
No. Lubrication
Point
Filling
Quantity
Lubricant Lubrication
Interval
Top-up
Quantity
Remarks
18 Journal for
hydraulic speed
governor
Turbine oil* Every 1 to 2
months
19 Adjusting gear of
reference speed
setter
200g Grease
Servogem-2
Every 1 to 2
months
10g
20 Bearing of
trimming device
Turbine oil* Every 1 to 2
months
21 Hinge of cold
reheat swing
check valve
Molykote U After every
dismantling
Use no oil
or grease
22 Stem guides of
shaft seal steam
valve
Molykote U After every
dismantling
Use no oil
or grease.
Lubrication
point not
shown
23 Shaft seal steam
valve actuators
7 to 9 kg Hydraulic oil
to DIN 51517
and VDMA
24318 H-LP
oils**
1stoil change
after 6
months,
thereafter
every12
months.
7 to 9 kg Lubrication
point not
shown
* Turbine oil 46/Servoprime 46 of IOC, Turbinol 47 of HPCL or equivalent
** HLP 46 (VG) ISO of IOC