Section-7.
Technical Specification
7.1.1 Type-A LAN Switch
Item      Description of Item   Required Specification                                           Offered by TOSS Ltd.
No
          Brand Name            Internationally Reputed brand (To be mentioned)
          Model                 To be mentioned by the bidder
          Country of Origin     To be mentioned by the bidder
          Country of            To be mentioned by the bidder
          Assemble
7.1.1.1   Standard                     IEEE 802.3 10BASE-T
                                       IEEE 802.3u 100 BASE-TX
                                       IEEE 802.3ab 1000BASE-T
                                       IEEE 802.3z 1000BASE-X
                                       IEEE 802.3x full-duplex flow control
                                       IEEE 802.3af (Power over Ethernet)
7.1.1.2   Network Ports                24 10/100 Mbps auto sensing Fast Ethernet (at least 12
                                        ports have to be(PoE)
                                       2 GE optical ports with 2 SFP (SX)
7.1.1.3   Support                      IEEE 802.1Q Static VLAN (Up to 64)
                                       Port-based VLAN (Up to 26)
                                       IEEE 802.1p Class of Service(CoS)
                                       Port-based 3QoS
                                       DCP- Layer 3QoS
                                       IEEE 802.3ad (manual) Link Aggregation
                                       IEEE 802.1D Spanning Tree Protocol
                                       RFC 1157 SNMP v1
                                       RFC 1213 MIB II
                                       RFC 1643 Ethernet Interface MIB
                                       RFC 1493 Bridge MIB
                                       RFC 2131 DHCP client
                                       Private Enterprise MIB
                                       Rate Limiting
                                       Static IGMP and IGMP Snooping v1
                                       Port Mirroring Support
                                       Web-based configuration
                                       Configuration Backup/ Restore
                                       Password Access Control
                                       Firmware upgradeable
7.1.1.4   Performance                  Forwarding modes: Store-and-forward
          Specification                Bandwidth: 8.8Gbps
                                       Network latency: <20µs for 64-byte frames in store-and
                                        forward mode for 100 Mbps 100 Mbps transmission
                                       Buffer memory: 256 KB embedded memory per unit
                                       Address database size: 8,000 media access
                                        control(MAC) addresses per unit
                                       Addressing: 48-bit MAC Address
                                       Acoustic Noise: 41.8 db
7..1.2    Type-B                LAN Switch Should Support-
7.1.2.1   Network Protocol         IEEE 802.3 10BASE-T
          and Standards            IEEE 802.3u 100BASE-TX
          Compatibility            IEEE 802.3ab 1000BASE-T
                                   IEEE 802.3z 10BASE-X
                                   IEEE 802.3x Full Duplex flow control
7.1.2.2   Power Supply             180-240VAC/50-60 Hz universal input
7.1.2.3   Network Port             24 10/100 Mbps auto sensing Fast Ethernet Port
                                   2 GE optical port with two SFP(SX) modules
7.1.2.4   Administrative           IEEE 802.1Q Static VLAN (Up to 64)
          Switch                   Port-based VLAN (Up to 26)
          Management               IEEE 802.1p Class of service(CoS)
                                   Port based CoS
                                   DSCP – Layer 3QoS
                                   IEEE 802.3ad(manual) Link Aggregation
                                   IEEE 802.1D Spanning Tree Protocol
                                   RFC 1157 SNMP v1*
                                   RFC 1213 MIB ll
                                   RFC 1643 Ethernet Interface MIB
                                   RFC 1493 Bridge MIB
                                   RFC 2131 DHCP client
                                   Static IGMP and IGMP snooping v1
                                   Private Enterprise MIB
                                   Port Mirroring Support
                                   Web-based Configuration
                                   Rate Limiting
                                   Configuration Backup/Restore
                                   Password Access Control
                                   Firmware upgradeable
7.1.2.5   Performance              Forwarding modes: Store-and-forward
          Specifications           Bandwidth: at list 8.0Gbps
                                   Buffer memory: 256 KB embedded memory per unit
                                   Address database size: 8.000 media access control
                                    (MAC) addresses per system
                                   Addressing:48-bit MAC Address
7.2       Proxy Server,
          Firewall, Domain
          Controller
7.2.1     Proxy Server
7.2.2     Firewall
7.2.3     Domain Controller
          Brand                    HP/IBM/Sun and equivalent or higher
          Operating System         Linux
          No. of Processor         2
          Processor type           Intel Xeon Quad Core
          Processing               2 GHz
          Capacity
          RAM                      8 GB
          Internal Hard drive      2*146 G
          Network Interface        2 FE/GE Interface
          Card
          DVD                      20x SATA DVD Writer
          SCSI Interface           1
        Power Supply             AC 220V,1+1
        Rack mountable           Yes
        Rack 19”                 1(One)
        KVM                      Yes
7.3     File Sharing,
        Backup Server,
        DHCP, Print Log
        Server
7.3.1   File Sharing          
7.3.2   Backup Server         
7.3.3   DHCP                  
7.3.4   Print Log             
        Brand                    HP/IBM/Sun
        Operating System         Linux
        No. of Processor         2
        Processor type           Intel Xeon Quad Core
        Processing               2 GHz
        Capacity
        RAM                      8 GB
        Internal Hard drive      5*146 G
        Network Interface        2 FE/GE Interface
        Card
        DVD                      20x SATA DVD Writer
        SCSI Interface           1
        Power Supply             AC 220V,1+1
        Rack mountable           Yes
        Rack 19”                 1(One)
        KVM                      Yes
        RAID                     5
        Monitor                  17” LCD
7.4     Wireless Control      Security Enhanced security features include RF security to
        System (WLCS)         detect and avoid 802. 11 interference wireless LAN intrusion
        and Access Point      prevention, location and correction, 802.1x and 802. 11i
                              layer 2 security, IPSec and web authentication, management
                              frame protection and network admission control.
7.4.1   Wireless Control
        System(WLCS)
7.4.2   Access Point
        WLAN Standard            IEEE 802.11a, IEEE 802.11g/b
        802.11a Data             108 Mbps, 54 Mbps, 48 Mbps, 24 Mbps, 18
        rates                     Mbps, 12 Mbps, 9 Mbps, 6 Mbps
        802.11b Data             11 Mbps, 5.5 Mbps,2 Mbps, 1 Mbps
        rates
        802.11g Data             108 Mbps, 54 Mbps, 48 Mbps, 36 Mbps, 24
        rates                     Mbps, 28 Mbps, 12 Mbps, 9 Mbps, 6 Mbps,
                                  5.5 Mbps, 2 Mbps, 1 Mbps
        Operating                2.4 GHZ .5GHz
        Frequency
        Modulation               OFDM,CCK,QPSK,BPSK,DBPSK,DQPSK,
                                 16QAM, 64QAM,DSSS
          Security               WAP, WPA, TKIP, AES, LEAP, TLS, TTLS,
                                  PEAP, MS-CHAP, GTC, 802.1x, Wireless
                                  MAC Address Filtering
          WEP Encryption         40bit (=64 bit) 128 bit
          Length
          802.11a Indoor         100 meter
          Range
          802.11a                200 meter
          Outdoor Range
          802.11b/g              135 meter
          Indoor Range
          802.11b/g              290 meter
          Outdoor Range
          802.11a Output         17dBm
          Power
          802.11g Output         20dBm
          Range
          Port                   1 (One) 10/100PoE (8032.3af Power over
                                  Ethernet)
          Antenna Type           Internal/Integrated Antenna x2
          Remote                 SNMP, HTTP, Telnet
          Management
          Protocol
7.5       Antivirus              Licensed Antivirus for 50 (fifty) PCs
                                 3 years
7.6       Passive Network
7.6.1     Optical Fiber and      Core: 6 Core
          Connector              Length:200 meter
                                 System Specification :ANSI/ TIA/EIA-568-B, ANSI/
                                  TIA/EIA-569-A, ANSI/ TIA/EIA-607, ANSI/ TIA/EIA-
                                  606-A
                                 Connectors : LC Connector
7.6.2     UTP Cable              CAT 6 4 pair UTP LSZH Cable
          Network                14,000 meter
                                 ANSI/ TIA/EIA-568-B.1 and B.2 standards.
                                 PoE Connectivity follow the IEEE 802.3af (PoE)
                                  standards.
7.6.2.1   UTP Cable              Conductor: 24AWG solid bare copper.
                                 Insulation: FEP/Polyolefin
                                 Cabling :Four Unshielded twisted pair cable around a
                                  star filler member
                                 Jacket: Flame redundant PVC
                                 Impendence: 100Ω
                                 Operating temperature range:-20°C to +80°C
                                 Bulk cable weight: 4.31 Kg / 100 m.
                                 Maximum recommended pulling tension (during
                                  installation) : 100N
                                 Minimum bend radius (during Installation): 2.54 cm
7.6.2.2   Patch Panel UTP        The Patch Panel shell be modular;
          Cables                 19” Rack mountable,
                                 Cat 6
                                 Shielded & shell have 24 port
                                 Connectors :RJ45 or 8P8C
                                 Permanent connectors shall be 110 IDC contacts
                                 T568A and T568B wiring standard
                                  Panel shall be design for 24 AWG solid conductors
7.6.2.3   UTP Patch Cord         factory crimped
                                 3 meter
                                 Cat 6
                                 ANSI/ TIA/EIA-568-B.2 standard
                                 120 ps(around)
7.6.2.4   Cable Organizer
7.6.2.5   Face Plates
7.6.2.6   UTP Cable
          Connector
7.6.2.7   Channel, Flexible
          Pipe and other
          cable laying
          materials
          Channel                ½ - 1500 meter
                                 ¾ - 1000 meter
                                 1” – 500 meter
                                 1.5” – 250 meter
                                 2” – 250 meter
          Flexible pipe          1” – 500 meter
                                 1.5” – 250 meter
                                 2” – 200 meter
7.6.2.8   Brand                  Panduit
                                 Systimax
                                 AMPS
                                 AVAYA
                                 Equivalent or higher in performance
7.7       Uninterrupted        Bidder has to include five (5) no of 1 KVA UPS each with a
          Power Supply        back time of Half an Hour on Full load.
7.8       RACK
7.8.1     Wall Mounted         12 U(21 inches Height)
          Racks                EIA-310-D standards
7.8.2     Floor Mounted        42 U( 72 inches Height)
          Racks                EIA-310-D standards
                              Moreover, it should contain following additional feature:
                              a) Separate runway for top and bottom cable runs.
                              b) Superior ventilation
                              c)At least four AC fans for cooling
                              d) Single front perforated doors or sealed glass door with
                              force cooling.
                              e) Duel/ single flash mount doors.
                                    f) Sub-distribution board including ground bar, AC
                                    distribution.
                                    g) Vertical cable organizer, 8 cable rings.
                                    h)PDU should have at least 8 unit C13 &2 units C19
                                    connectivity.
7.9      Spare Parts for
         Existing Router and
         Storage Devices
7.9.1                               Bidder has to include following two cards for
                                    BTCL’s existing AR4600 router
                                     RT–FIC-8E1 (75)
                                     RT–FIC-2GEF
7.9.2    USB Mass storage               80 GB USB
         Devices
7.9.3    DVD Writer
7.10     Raised Floor
7.11     Earthling
7.12     Documentation
7.13     Requirement for
         service
7.13.1   Installation Service       1.    The Bidder shall be responsible to provide all service
                                          related to installation, service for all equipment cover by
                                          the purchase.
                                     2. All cost service shall be quoted and failure to quote shall
                                          be consider that the Bidder proposes to provide this
                                          service totally “free of charge” to BTCL.
7.13.2   Inter- connecting      The Bidder shall be responsible for making inter connection
         and Inter-Working      facility include supply of all require material, cabal , connector
         with the existing      etc. between proposed system and BTCL’s existing network. The
         system                 bidder in his offer shall quite all costs for material and service .
                                Failure to quote shall be treated as “non compliance” to BTCL.
                                The bidder shall responsible to ensure that all the system covered
                                by this perches shall be able to inter-work with all the existing
                                system of BTCL. The bidder shall make necessary survey and
                                shall also be entirely responsible to solve any mismatch, if
                                encountered. The bidder shall quote any extra cost, if necessary,
                                and if the bidder fails to quote for this work, he shall have to
                                complete this work at his own cost. No subsequent additional
                                request for costs for required interfaces, if any, shall be
                                entertained.
                                In all access switch site bidder has to connect UPS and switch
                                with existing AC power source. Bidder has to include necessary
                                power accessories with his offer.
7.13.3   Training               The bidder shall provide necessary training facilities to the BTCL
                                personnel in order to enable running the equipment purchased
                                under this contract.
                                 The bidder shall provide training at BTCL premises
                                    a) Number of BTTB Engineer : 6(six)
                                    b) Number of minimum working days : 8 (Eight) days for
                                        wireless control system and 10 (ten) days for server and
                                        switch system.
                                   c) Per diam charge to BTTB Executive : BD Taka 600 (six
                                        hundred) per day per person
7.13.4   Maintenance                The bidder at his own cost shall provide full
         Support Service up             maintenance support service for all equipment and
         to Warranty period             service covered by this purchase up to the end of
                                        warranty period.
                                    The maintenance support service shall cover at list (but
                                        not limit to) the following service
                                   1. Response in the shortest possible time during any call
                                        by BTCL.
                                   2. Help to solve different software and hardware problems
                                        related to proper O&M of the equipment or
                                        modification/ addition/ deletion of any feather/ service.
                                   3. Advice BTCL about different aspects of O&M, system
                                        dimensioning, expansion etc.
                                   4. Transfer of technology to BTCL personnel.
                                   5. This support shall only be limited to the operational and
                                        maintenance activities. The bidder shall separately quote
                                        for this. Repair and replacement of hardware covered by
                                        warranty shall be included in the hardware cost.
7.13.5   Testing and          Before acceptance of the install system/ equipment, BTCL
         Commissioning        representatives shall carryout , on site, detailed test of all
                              equipment to ascertain there inter-working ability with relevant
                              equipment of the other manufacturers, working reliability, and
                              concurrence to agree technical and other specifications, inventory
                              checking of installed equipment etc. such test shall be termed as
                              “Acceptances Test(AT) “ . Prior to commitment of such test, the
                              contractor shall submit a proposed procedure for the AT to be
                              subsequently passed by the Project Director. A joint team of
                              BTCL engineers and bidder’s engineers will do the AT.
                              BTCL shall start such test within one month after receipt of the
                              request . The bidder may , upon agreement by the both party,
                              offer AT for any part or part of the total work . such request for
                              partial AT may also be asked for by BTCL.
                              The bidder shall be totally responsible for arrangement of all
                              equipment, consumables, test gears and measuring equipment for
                              the AT. All cost for materials and service shall be quote and
                              failure to quote shall be considered that the bidder propose to
                              provide this service totally “Free of Charge” to BTCL.
                              The bidder’s engineer shall be liable to make necessary
                              arrangement complete any kinds of tests requested by BTCL AT
                              members during AT procedure .