L

Compensating and Extension Cables


L
2
Content
COMPENSATING AND
EXTENSION CABLES
page
Applications ..................................................................................................................................................................................... L/4-5
Compensating and extension cables for thermocouples shape
PVC insulated compensating and extension cables up to +70C

A 1 L twisted ................................................................................................................................ round ...................................... L/6

A 1 L single ................................................................................................................................ round ...................................... L/6

A 16 L ................................................................................................................................ oval ...................................... L/6

A 9 L ................................................................................................................................ round ...................................... L/7

A 9-100 L ................................................................................................................................ round ...................................... L/7

A 9-075 L ................................................................................................................................ round ...................................... L/7

A 9-050 L ................................................................................................................................ round ...................................... L/7

A 9-022 L ................................................................................................................................ round ...................................... L/7

A 12 L ................................................................................................................................ oval ...................................... L/8

A 12 D ................................................................................................................................ oval ...................................... L/8
Screened PVC insulated compensating and extension cables up to +70C

A 5 L with overall copper screen .......................................................................... round ...................................... L/9

A 5-075 L with overall copper screen .......................................................................... round ...................................... L/9

A 5-050 L with overall copper screen .......................................................................... round ...................................... L/9

A 5-022 L with overall copper screen .......................................................................... round ...................................... L/9

A 20 L with Alu-foil screen ....................................................................................... round ...................................... L/10

A 20-022 L with Alu-foil screen ....................................................................................... round ...................................... L/10

A 20 D with Alu-foil screen ....................................................................................... round ...................................... L/10
Multi-pair PVC insulated compensating and extension cables up to +70C

A 9-L ................................................................................................................................ round ...................................... L/11

A 9-LSY with steel wire armouring ............................................................................ round ...................................... L/11
Besilen

insulated compensating and extension cables up to +180C



A 1 LB twisted ................................................................................................................................ round ...................................... L/12

A 16 LB ................................................................................................................................ oval ...................................... L/12

A 15 L ................................................................................................................................ round ...................................... L/13

A 15-075 L ................................................................................................................................ round ...................................... L/13

A 15-050 L ................................................................................................................................ round ...................................... L/13

A 15-022 L ................................................................................................................................ round ...................................... L/13

A 3 Ln ................................................................................................................................ oval ...................................... L/14

A 4 Ln with steel wire armouring ............................................................................ oval ...................................... L/14

A 11 Lr with fibre-glass braiding and steel wire armouring ................................. round ...................................... L/15

A 11-4 Lr with fibre-glass braiding and steel wire armouring ................................. round ...................................... L/15

A 11 Dr with fibre-glass braiding and steel wire armouring ................................. round ...................................... L/15

A 13 L with fibre-glass braiding .............................................................................. oval ...................................... L/16
L
3
Content
COMPENSATING AND
EXTENSION CABLES
page
shape
Screened Besilen

insulated compensating and extension cables up to +180C



A 6 L with Alu-foil screen ....................................................................................... round ...................................... L/17

A 6-022 L with Alu-foil screen ....................................................................................... round ...................................... L/17

A 6 D with Alu-foil screen ....................................................................................... round ...................................... L/17

A 15 LC with overall copper screen .......................................................................... round ...................................... L/18

A 15-075 LC with overall copper screen .......................................................................... round ...................................... L/18

A 15-050 LC with overall copper screen .......................................................................... round ...................................... L/18

A 15-022 LC with overall copper screen .......................................................................... round ...................................... L/18
Fibre-glass insulated compensating and extension cables up to +180C / +200C

A 15-022 fibre-glass / Besilen

.................................................................................. round ...................................... L/19



A 15-G 022 with outer fibre-glass braiding ................................................................... round ...................................... L/19

A 3 L with Stex braiding ................................................................................... oval ...................................... L/20

A 4 L with Stex braiding and steel wire armouring .................................... oval ...................................... L/20
FEP insulated compensating and extension cables up to +180C

A 18 L ................................................................................................................................ round ...................................... L/21

A 18-022 L ................................................................................................................................ round ...................................... L/21

A 19 L with overall copper screen .......................................................................... round ...................................... L/21

A 19-022 L with overall copper screen .......................................................................... round ...................................... L/21
Extension cables for thermocouples FE-CuNi and NiCr-Ni
Fibre-glass insulated extension cables up to +250C / +400C

Th LGS with fibre-glass braiding and steel wire armouring, up to +250C ... round ...................................... L/22

Th LRS with special fibre-glass braiding and steel wire armouring, up to +400C round ...................................... L/22
PFA insulated extension cables up to +250C

Th LTS with steel wire armouring ............................................................................ round ...................................... L/23

Th LTV with stainless steel wire armouring ........................................................... round ...................................... L/23
Connection cables for resistance thermometers
PFA insulated connection cables up to +250C

TGV with fibre-glass braiding and stainless steel wire armouring ................ round ...................................... L/24
Connection cables for resistance thermometers, special and hybrid cables

Survey ..................................................................................................................................................................................................... L/25

Compensating and Extension Cables for the automotive industry

Survey ..................................................................................................................................................................................................... L/26-27
Colour code and temperature range for compensating and extension cables ......................................... L/28
Besilen

is a specially developed Silicone rubber-based material


with good electrical characteristics and
it is a registered trademark of SBRCKSKES GmbH & Co. KG.
L
4
n
General Information
Temperature is an important factor in many areas concerning the environment, scientific research and production. It is a thermo-
dynamic variable that defines the heat content of a material. Material strength changes with alternating temperature. As a con-
sequence, the characteristics of materials have to be examined at different temperatures. To obtain a temperature value, defined
temperature parameters are used. Here the parameters can be defined, for example, as the freezing and boiling points of water.

For temperature measurement temperature dependent characteristics of materials have to be taken into account. These include
such things as thermal expansion (expansion thermometer), the dependance of the electric resistance on metallic conductors
(electrical thermometer) and electromotive force (thermocouple) etc.. A temperature measuring device with a thermocouple as
a data indicator tends to consist of the thermometer itself with a measuring point, an extension cable, a cold junction with a spe-
cified constant temperature and a voltmeter.
The value of the electromotive force (EMF) produced by the thermocouple is determined by the difference between the measuring
temperature and the so-called free ends of the thermocouple which are mounted in the connection head. As the connection
head is usually relatively close to the measuring point, it is frequently exposed to temperature fluctuations. For this reason, a con-
nection cable with the same thermo-electric properties as the thermocouple is used between the thermocouple and the cold
junction.
This link-up provides the compensating/extension cable.
n
Sketch
n
Materials
We differentiate between thermocouple cable and compensating cable. Cables made of original materials are called extension
or thermocouple cables, whereas conductor materials made of substitutes are known as compensating cables.
n
Compensating cables
The compensating wires and strands are composed of alloys which do not have to be identical with the corresponding thermo-
couple. Substitute material means that the thermo-electric characteristics in the allowed temperature range (usually 0 up to
+200 C) for the compensating cable must be the same as those of the corresponding thermocouple. They are identified with
the letter C adapted to DIN IEC 584. The C appears behind the code letter identifying the thermocouple, for example KC.

n
Extension cables
Extension cables are made of conductors with identical nominal structure to the corresponding thermocouple. They are identified
with the letter X adapted to DIN IEC 584, which appears behind the code letter iden ti fying the thermocouple, for example JX.
They are normally tested within a temperature range of 0 up to +200C.
n
Thermocouple cables
Thermocouple cables consist of the same element material as the thermocouple and are tested for the same temperatures.
These Sspecial cables are manufactured on customer request. PVC, fibre-glass and Stex insulated or sheathed com-
pensating and extension cables are not suitable for outdoor use. Exception: PVC sheathed solid conductors can be used for un-
derground laying.
connection point
connection head
compensating/
extension cable
protecting tube
thermocouple
measuring device
measuring point
cold junction
copper feed line
Applications
COMPENSATING AND
EXTENSION CABLES
L
5
n
Electrical characteristics:
Material Specific electric Resistance in /m
resistance at 20C mm mm
x cm 0,20 1,38
Cu Ni 49,0 15,60 0,328
So Ni 51,0 16,26 0,341
Ni Cr 72,0 22,90 0,481
Ni 27,0 8,59 0,180
So Pt 12,0 3,82 0,0802
E-Cu 1,7 0,54 0,011
Fe 12,0 3,82 0,08
BPX 12,5 3,98 0,084
Ni Cr Si 98,0 31,20 0,655
Ni Si 34,0 10,80 0,227
So Ni Si 52,0 16,55 0,347
n
Because the thermal electromotive force values are decisive, the indicated specific resistance and meter resistance figures
can only be considered as approximate values, tolerances have to be agreed between producer and customer. Limit deviations
within the thermoelectric voltage range can only be guaranteed for positive and negative conductors bought together from S
BRCKSKES GmbH & Co. KG.
The standard 43710 was withdrawn in April 1994, but we continue, also to manufacture compensating and extension cables
colour coded to DIN 43714.
n
Example:
Type A 12 D for thermocouple type J acc. to DIN IEC 584 = item no. 44512 82
Type A 9-4 LSY for thermocouple type L acc. to DIN 43713 = item no. 46204 92
n
Note:
In addition to our standard compensating cables featured on the following pages, we also produce special cables on customer
request and according to practically every recognised foreign standard.
For special compensating cables we would request the following information: stranded or solid conductor, no. of cores, cross-
section, element-type, core insulation and sheath material, screening or armour requirements and the tempe rature range. Minimum
order quantity for special cables is 500 m or 1000 m.
n
You will find further information about the safe application of cables on pages N/28-38.
Bthermocouple code
for thermocouple EMF at 100 C in mV cable type Sthermocouple code
strands single wire
Type T 4,28 TX 58 88
Type J 5,27 JX 52 82
Type K 4,10 KCA 95 15
Type K 4,10 KCB 99 19
Type K 4,10 KX 54 84
Type E 6,32 EX 53 83
Type R/S 0,65 R/SCB 97 17
Type N 2,77 NC 91 11
for thermocouple EMF at 100 C in mV cable type Sthermocouple code
strands single wire
Type L 5,37 LX 92 12
Type K 4,10 KCA 94 14
Type R/S 0,65 R/SCB 96 16
Type U 4,25 UX 98 18
Type B 0,00 BC-100 01 21
Type B 0,033 BC-200 02 22
Applications
COMPENSATING AND
EXTENSION CABLES
L
6
33
q q
DIN 43710/43714 (not valid for *type B)
for thermocouple EMF at 100 C in mV cable type A 1 L twisted A 1 L single A 16 L
item no. item no. item no.
Type L 5,37 LX 04018992 04028992 04035992
Type K 4,10 KCA 04018994 04028994 04035994
Type R/S 0,65 R/SCB 04018996 04028996 04035996
Type U 4,25 UX 04018998 04028998 04035998
*Type B 0,00 BC-100 04018901 04028901 04035901
*Type B 0,033 BC-200 04018902 04028902 04035902
*Not standardized compensating cable for thermocouples type B with application temperatures up to 100C resp. 200 C.
C = compensating cables X = extension cables
DIN IEC 584
for thermocouple EMF at 100 C in mV cable type A 1 L twisted A 1 L single A 16 L
item no. item no. item no.
Type T 4,28 TX 04018958 04028958 04035958
Type J 5,27 JX 04018952 04028952 04035952
Type K 4,10 KCA 04018995 04028995 04035995
Type K 4,10 KCB 04018999 04028999 04035999
Type K 4,10 KX 04018954 04028954 04035954
Type E 6,32 EX 04018953 04028953 04035953
Type R/S 0,65 R/SCB 04018997 04028997 04035997
Type N 2,77 NC 04018991 04028991 04035991
We also manufacture compensating and extension cables colour coded to DIN VDE 43714 06/79
and the basic values laid down in DIN VDE 43710 which was withdrawn in April 1994.
Type: A 1 L twisted A 1 L single A 16 L
Conductor cross section: 1,5 mm
2
1,5 mm
2
0,75 mm
2
Outer diameter: approx. 4,8 mm approx. 2,4 mm approx. 1,9 x 3,8 mm
Weight/100m: approx. 3,2 kg approx. 3,2 kg approx. 1,8 kg
Technical data:
Min. bending radius: 7.5 x d
Radiation resistance: 8 x 10
7
cJ/kg
Temperature range fixed laying: -40/+70 C
of insulation: flexible application: +5/+70 C
Insulation resistance: > 1M x km
Fire performance: flame retardant and self-extinguishing
acc. to IEC 60332-1-2 + EN 60332-1-2
Absence of acc. to RoHS directive of the European Union
harmful substances: see page N/14
Construction:
Insulation: PVC TI2 acc. to DIN VDE 0281 part 1
+ HD 21.1
Stranding: 2 cores together
2 cores seperately
A 16 L:
2 cores parallel
positive conductor with coloured stripe
Shape: round
A 16 L: oval
Conductor
construction: strand
A1 L twisted
A1 L single
A16 L
PVC insulated cables A 1 L twisted A 1 L single A 16 L
COMPENSATING AND
EXTENSION CABLES
Also available with
cross-sections
1,0 mm
2
, 0,75 mm
2
,
0,5 mm
2
and 0,22 mm
2
!
L
7
33
A 9 L A 9-100 L A 9-075 L A 9-050 L
A 9-022L
DIN 43710 / 43714 (not valid for *type B)
*Not standardized compensating cable for thermocouples type B with application temperatures up to 100C resp. 200 C.
C = compensating cables X = extension cables
We also manufacture compensating and extension cables colour coded to DIN VDE 43714 06/79
and the basic values laid down in DIN VDE 43710 which was withdrawn in April 1994.
DIN IEC 584
Technical data:
Min. bending radius: 7.5 x d
Radiation resistance: 8 x 10
7
cJ/kg
Temperature range fixed laying: -40/+70 C
of insulation: flexible application: +5/+70 C
Insulation resistance: > 1M x km
Fire performance: flame retardant and self-extinguishing
acc. to IEC 60332-1-2 + EN 60332-1-2
Absence of acc. to RoHS directive of the European Union
harmful substances: see page N/14
Construction:
Insulation: PVC acc. to TI2 acc. to DIN VDE 0281
part 1 + HD 21.1
Stranding: 2 cores together
Sheath: PVC TM2 acc. to
DIN VDE 0281 part 1 + HD 21.1
Shape: round
Conductor
construction: strand
PVC insulated cables A 9 L A 9-100 L A 9-075 L A 9-050 L A 9-022 L
COMPENSATING AND
EXTENSION CABLES
for EMK at cable type A 9 L A 9-100 L A 9-075 L A 9-050 L A 9-022 L
thermocouple 100 C in mV item no. item no. item no. item no. item no.
Type L 5,37 LX 04428992 04426992 04425992 04423992 04421992
Type K 4,10 KCA 04428994 04426994 04425994 04423994 04421994
Type R/S 0,65 R/SCB 04428996 04426996 04425996 04423996 04421996
Type U 4,25 UX 04428993 04426993 04425993 04423993 04421993
*Type B 0,00 BC-100 04428901 04426901 04425901 04423901 04421901
*Type B 0,033 BC-200 04428902 04426902 04425902 04423902 04421902
Type: A 9 L A 9-100 L A 9-075 L A 9-050 L A 9-022 L
Conductor cross section: 1,5 mm
2
1,0 mm
2
0,75 mm
2
0,50 mm
2
0,22 mm
2
Outer diameter: approx. 6,1 mm approx. 5,1 mm approx. 4,9 mm approx. 4,3 mm approx. 3,3 mm
Weight/100m: approx. 5,0 kg approx. 4,4 kg approx. 3,9 kg approx. 2,9 kg approx. 1,6 kg
for EMK at cable type A 9 L A 9-100 L A 9-075 L A 9-050 L A 9-022 L
thermocouple 100 C in mV item no. item no. item no. item no. item no.
Type T 4,28 TX 04428958 04426958 04425958 04423958 04421958
Type J 5,27 JX 04428952 04426952 04425952 04423952 04421952
Type K 4,10 KCA 04428995 04426995 04425995 04423995 04421995
Type K 4,10 KCB 04428999 04426999 04425999 04423999 04421999
Type K 4,10 KX 04428954 04426954 04425954 04423954 04421954
Type E 6,32 EX 04428953 04426953 04425953 04423953 04421953
Type R/S 0,65 R/SCB 04428997 04426997 04425997 04423997 04421997
Type N 2,77 NC 04428991 04426991 04425991 04423991 04421991
A 9-022 L:
New Item!
Old Item 0450
a
ls
o
a
v
a
ila
b
le
a
s
h
a
lo
g
e
n
-fre
e
c
o
n
s
tru
c
tio
n
!
L
8
A 12 L
A 12 D
q q
33
Type: A 12 L A 12 D
Conductor cross section: 1,5 mm
2
1,5 mm
2
Outer dimension: approx. 3,7 x 6,1 mm approx. 3,2 x 5,3 mm
Weight/100m: approx. 4,2 kg approx. 4,3 kg
DIN IEC 584
for thermocouple EMF at 100 C in mV cable type A 12 L A 12 D
item no. item no.
Type T 4,28 TX 04448958 04458988
Type J 5,27 JX 04448952 04458982
Type K 4,10 KCA 04448995 04458915
Type K 4,10 KCB 04448999 04458919
Type K 4,10 KX 04448954 04458984
Type E 6,32 EX 04448953 04458983
Type R/S 0,65 R/SCB 04448997 04458917
Type N 2,77 NC 04448991 04458911
DIN 43710/43714 (not valid for *type B)
for thermocouple EMF at 100 C in mV cable type A 12 L A 12 D
item no. item no.
Type L 5,37 LX 04448992 04458912
Type K 4,10 KCA 04448994 04458914
Type R/S 0,65 R/SCB 04448996 04458916
Type U 4,25 UX 04448998 04458918
*Type B 0,00 BC-100 04448901 04458921
*Type B 0,033 BC-200 04448902 04458922
We also manufacture compensating and extension cables colour coded to DIN VDE 43714 06/79
and the basic values laid down in DIN VDE 43710 which was withdrawn in April 1994.
*Not standardized compensating cable for thermocouples type B with application temperatures up to 100C resp. 200 C.
C = compensating cables X = extension cables
Technical data:
Min. bending radius: A 12 L: 7.5 x d
A 12 D: 12 x d
Radiation resistance: 8 x 10
7
cJ/kg
Temperature range fixed laying: -40/+70 C
of insulation: flexible application: +5/+70 C
Insulation resistance: > 1M x km
Fire performance: flame retardant and self-extinguishing
acc. to IEC 60332-1-2 + EN 60332-1-2
Absence of acc. to RoHS directive of the European Union
harmful substances: see page N/14
Construction:
Insulation: PVC TI2 acc. to DIN VDE 0281 part 1
+ HD 21.1
Stranding: 2 cores parallel
Sheath: PVC TM2 acc. to
DIN VDE 0281 part 1 + HD 21.1
Shape: oval
Conductor
construction: strand resp. wire
PVC insulated cables A 12 L A 12 D
COMPENSATING AND
EXTENSION CABLES
A 12 L
also available with cross-
sections 1,0 mm
2
, 0,75 mm
2
,
0,5 mm
2
and 0,22 mm
2
!
L
9
A 5 L A 5-075 L A 5-050 L A 5-022 L
q q
33
DIN IEC 584
DIN 43710/43714 (not valid for *type B)
We also manufacture compensating and extension cables colour coded to DIN VDE 43714 06/79
and the basic values laid down in DIN VDE 43710 which was withdrawn in April 1994.
*Not standardized compensating cable for thermocouples type B with application temperatures up to 100C resp. 200 C.
C = compensating cables X = extension cables
Technical data:
Min. bending radius: 7.5 x d
Radiation resistance: 8 x 10
7
cJ/kg
Temperature range fixed laying: -40/+70 C
of insulation: flexible application: +5/+70 C
Insulation resistance: > 1M x km
Fire performance: flame retardant and self-extinguishing
acc. to IEC 60332-1-2 + EN 60332-1-2
Absence of acc. to RoHS directive of the European Union
harmful substances: see page N/14
Construction:
Insulation: PVC TI2 acc. to DIN VDE 0281 part 1
+ HD 21.1
Stranding: 2 cores together
Wrapping: PETP foil
Screen: tinned copper braiding
Sheath: PVC TM2 acc. to DIN VDE 0281 part 1
+ HD 21.1
Shape: round
Conductor
construction: strand
PVC insulated cables A 5 L A 5-075 L A 5-050 L A 5-022 L
COMPENSATING AND
EXTENSION CABLES
A 5-022 L:
New Item group!
Old Item group 0458
4, 8 or 16 pairs
on request!
w
ith
o
v
e
r
a
ll
c
o
p
p
e
r
s
c
r
e
e
n
a
ls
o
a
v
a
ila
b
le
a
s
h
a
lo
g
e
n
-fre
e
c
o
n
s
tru
c
tio
n
!
Type: A 5 L A 5-075 L A 5-050 L A 5-022 L
Conductor cross section: 1,5 mm
2
0,75 mm
2
0,50 mm
2
0,22 mm
2
Outer diameter: approx. 6,8 mm approx. 5,6 mm approx. 5,0 mm approx. 3,8 mm
Weight/100m: approx. 6,8 kg approx. 4,5 kg approx. 3,7 kg approx. 2,2 kg
for thermocouple EMK at cable type A 5 L A 5-075 L A 5-050 L A 5-022 L
100 C in mV item no. item no. item no. item no.
Type T 4,28 TX 04568958 04565958 04563958 04561958
Type J 5,27 JX 04568952 04565952 04563952 04561952
Type K 4,10 KCA 04568995 04565995 04563995 04561995
Type K 4,10 KCB 04568999 04565999 04563999 04561999
Type K 4,10 KX 04568954 04565954 04563954 04561954
Type E 6,32 EX 04568953 04565953 04563953 04561953
Type R/S 0,65 R/SCB 04568997 04565997 04563997 04561997
Type N 2,77 NC 04568991 04565991 04563991 04561991
for thermocouple EMK at cable type A 5 L A 5-075 L A 5-050 L A 5-022 L
100 C in mV item no. item no. item no. item no.
Type L 5,37 LX 04568992 04565992 04563992 04561992
Type K 4,10 KCA 04568994 04565994 04563994 04561994
Type R/S 0,65 R/SCB 04568996 04565996 04563996 04561996
Type U 4,25 UX 04568998 04565998 04563998 04561998
*Type B 0,00 BC-100 04568901 04565901 04563901 04561901
*Type B 0,033 BC-200 04568902 04565902 04563902 04561902
L
10
A 20 L A 20-022 L
A 20 D
33
Technical data:
Min. bending radius: A 20 L, A 20-022 L: 7,5 x d
A 20 D: 12 x d
Radiation resistance: 8 x 10
7
cJ/kg
Temperature range fixed laying: -40/+70 C
of insulation: flexible application: +5/+70 C
Insulation resistance: > 1M x km
Fire performance: flame retardant and self-extinguishing
acc. to IEC 60332-1-2 + EN 60332-1-2
Absence of acc. to RoHS directive of the European Union
harmful substances: see page N/14
Construction:
Insulation: PVC TI2 acc. to DIN VDE 0281 part 1
+ HD 21.1
Stranding: 2 cores together
Wrapping: PETP foil, bare copper earth wire
0,5 mm
Screen: Alu-foil
Sheath: A 20 L:
PVC TM2 acc. to DIN VDE 0281 part 1
+ HD 21.1
A 20 D:
PVC YM3 acc. to DIN VDE 0207 part 5
Shape: round
Conductor
construction: strand resp. wire
PVC insulated cables A 20 L A 20-022 L A 20 D
COMPENSATING AND
EXTENSION CABLES
w
ith
A
lu
-
fo
il
s
c
r
e
e
n
Type: A 20 L A 20-022 L A 20 D
Conductor cross section: 1,5 mm
2
0,22 mm
2
1,5 mm
2
Conductor construction: approx. 7,0 mm approx. 4,0 mm approx. 6,4 mm
Weight/100m: approx. 5,9 kg approx. 2,4 kg approx. 5,5 kg
for thermocouple EMK at cable type A 20 L A 20-022 L A 20 D
100 C in mV item no. item no. item no.
Type T 4,28 TX 04548958 04541958 04648988
Type J 5,27 JX 04548952 04541952 04648982
Type K 4,10 KCA 04548995 04541995 04648915
Type K 4,10 KCB 04548999 04541999 04648919
Type K 4,10 KX 04548954 04541954 04648984
Type E 6,32 EX 04548953 04541953 04648983
Type R/S 0,65 R/SCB 04548997 04541997 04648917
Type N 2,77 NC 04548991 04541991 04648911
for thermocouple EMK at cable type A 20 L A 20-022 L A 20 D
100 C in mV item no. item no. item no.
Type L 5,37 LX 04548992 04541992 04648912
Type K 4,10 KCA 04548994 04541994 04648914
Type R/S 0,65 R/SCB 04548996 04541996 04648916
Type U 4,25 UX 04548998 04541998 04648918
*Type B 0,00 BC-100 04548901 04541901 04648921
*Type B 0,033 BC-200 04548902 04541902 04648922
DIN IEC 584
DIN 43710/43714 (not valid for *type B)
We also manufacture compensating and extension cables colour coded to DIN VDE 43714 06/79
and the basic values laid down in DIN VDE 43710 which was withdrawn in April 1994.
*Not standardized compensating cable for thermocouples type B with application temperatures up to 100C resp. 200 C.
C = compensating cables X = extension cables
L
11
A 9 - L
A 9 - LSY
q q
33
Type: A 9 - L A 9 - LSY
Conductor cross section: 1,5 mm
2
1,5 mm
2
no. of for outer weight cable A 9 - L outer weight cable A 9 - LSY
cores thermo- approx. approx. type item no. approx. approx. type item no.
couples in mm kg/100 m in mm kg/100 m
2 1 6,1 6,4 A9 L 044289 8,5 11,3 A9-2LSY 046289
4 2 7,1 9,8 A9-4 L 044204 9,5 15,0 A9-4LSY 046204
6 3 8,7 14,1 A9-6 L 044206 11,3 21,4 A9-6LSY 046206
12 6 11,9 25,8 A9-12L 044212 14,7 36,0 A9-12LSY 046212
16 8 13,2 33,2 A9-16L 044216 16,4 46,9 A9-16LSY 046216
20 10 15,0 42,2 A9-20L 044220 18,0 57,2 A9-20LSY 046220
24 12 16,7 49,2 A9-24L 044224 19,7 64,0 A9-24LSY 046224
32 16 18,8 65,4 A9-32L 044232 21,4 80,5 A9-32LSY 046232
36 18 19,5 72,6 A9-36L 044236 22,1 88,6 A9-36LSY 046236
40 20 20,9 80,6 A9-40L 044240 24,1 100,1 A9-40LSY 046240
In case of order, please indicate the corresponding thermocouple! (please see Sthermo couple code page L/5)
Example: Type A 9 - 16 L for thermocouple type R/S acc. to DIN 43713 = item no. 4421696
The type A 9-L can also be manufactured with solid conductors 1,38 mm .
The type identification for solid types is: type A 9 - D (item group 0463).
If no stock material is available, the min. order quantity is 500 m.
The types of multi-paired compensating cables can also be delivered pair-wise twisted and pairs totally twisted for additional charge.
Technical data:
Min. bending radius: A 9 - L: 7.5 x d
A 9 - LSY: 12 x d
Radiation resistance: 8 x 10
7
cJ/kg
Temperature range fixed laying: -40/+70 C
of insulation: flexible application: +5/+70 C
Insulation resistance: > 1M x km
Fire performance: flame retardant and self-extinguishing
acc. to IEC 60332-1-2 + EN 60332-1-2
Absence of acc. to RoHS directive of the European Union
harmful substances: see page N/14
Construction:
Insulation: PVC TI2 acc. to DIN VDE 0281 part 1
+ HD 21.1
Core marking: from 4 cores pair-wise numbered
Stranding: cores together in layers
Sheat: PVC YM2 acc. to DIN VDE 0281 part 1
+ HD 21.1
Armouring: A 9 - LSY:
galvanized steel wire armouring
Shape: round
Conductor
construction: strand
PVC insulated cables A 9 - L A 9 - LSY with steel wire armouring
COMPENSATING AND
EXTENSION CABLES
m
u
l
t
i
-
p
a
i
r
e
d
Also available with
cross-sections
1,0 mm
2
, 0,75 mm
2
,
0,5 mm
2
and 0,22 mm
2
!
L
12
33
q q
Type: A 1 LB twisted A 16 LB
Conductor cross section: 1,5 mm
2
1,5 mm
2
Outer diameter/dim.: approx. 4,8 mm approx. 2,4 x 4,8 mm
Weight/100m: approx. 3,1 kg approx. 3,1 kg
DIN IEC 584
for thermocouple EMF at 100 C in mV cable type A 1 LB twisted A 16 LB
item no. item no.
Type T 4,28 TX 04048958 04068958
Type J 5,27 JX 04048952 04068952
Type K 4,10 KCA 04048995 04068995
Type K 4,10 KCB 04048999 04068999
Type K 4,10 KX 04048954 04068954
Type E 6,32 EX 04048953 04068953
Type R/S 0,65 R/SCB 04048997 04068997
Type N 2,77 NC 04048991 04068911
DIN 43710/43714 (not valid for *type B)
for thermocouple EMF at 100 C in mV cable type A 1 LB twisted A 16 LB
item no. item no.
Type L 5,37 LX 04048992 04068992
Type K 4,10 KCA 04048994 04068994
Type R/S 0,65 R/SCB 04048996 04068996
Type U 4,25 UX 04048998 04068998
*Type B 0,00 BC-100 04048901 04068901
*Type B 0,033 BC-200 04048902 04068902
We also manufacture compensating and extension cables colour coded to DIN VDE 43714 06/79
and the basic values laid down in DIN VDE 43710 which was withdrawn in April 1994.
*Not standardized compensating cable for thermocouples type B with application temperatures up to 100C resp. 200 C.
C = compensating cables X = extension cables
Technical data:
Min. bending radius: 7.5 x d
Radiation resistance: 2 x 10
7
cJ/kg
Temperature range fixed laying: -40/+180 C
of insulation: flexible application: -25/+180 C
short-time use: -25/+250 C
Insulation resistance: > 1M x km
Halogen-free: acc. to DIN VDE 0472 part 815 and IEC 60754-1
Fire performance: flame retardant and self-extinguishing
acc. to IEC 60332-1-2 + EN 60332-1-2
Corrosiveness of in compliance with IEC 60754-2 +
conflagration gases: EN 50267-2-2 + VDE 0482 part 267-2-2 -
no development of corrosive conflagration gases
Absence of acc. to RoHS directive of the European Union
harmful substances: see page N/14
Construction:
Insulation: Besilen

EI2 acc. to DIN EN 50363-1


Stranding: A 1 LB: 2 cores together
A 16 LB: 2 cores parallel
Shape: A 1 LB: round
A 16 LB: oval
Conductor
construction: strand
A 1 LB twisted
A 16 LB
Besilen

insulated cables A 1 LB twisted A 16 LB


COMPENSATING AND
EXTENSION CABLES
Also available with
cross-sections
1,0 mm
2
, 0,75 mm
2
,
0,5 mm
2
and 0,22 mm
2
!
L
13
33
A 15 L A 15-075 L A15-050 L A15-022 L
Type: A 15 L A 15-075 L A 15-050 L A 15-022 L
Conductor cross section: 1,5 mm
2
0,75 mm
2
0,50 mm
2
0,22 mm
2
Outer diameter: approx. 6,3 mm approx. 4,9 mm approx. 4,3 mm approx. 3,3 mm
Weight/100m: approx. 5,7 kg approx. 3,4 kg approx. 2,5 kg approx. 1,6 kg
We also manufacture compensating and extension cables colour coded to DIN VDE 43714 06/79
and the basic values laid down in DIN VDE 43710 which was withdrawn in April 1994.
DIN IEC 584
for thermocouple EMF at cable type A 15 L A 15-075 L A 15-050 L A 15-022 L
100 C in mV item no. item no. item no. item no.
Type T 4,28 TX 04268958 04265958 04263958 04261958
Type J 5,27 JX 04268952 04265952 04263952 04261952
Type K 4,10 KCA 04268995 04265995 04263995 04261995
Type K 4,10 KCB 04268999 04265999 04263999 04261999
Type K 4,10 KX 04268954 04265954 04263954 04261954
Type E 6,32 EX 04268953 04265953 04263953 04261953
Type R/S 0,65 R/SCB 04268997 04265997 04263997 04261997
Type N 2,77 NC 04268991 04265991 04263991 04261991
DIN 43710 / 43714 (not valid for *type B)
for thermocouple EMF at cable type A 15 L A 15-075 L A 15-050 L A 15-022 L
100 C in mV item no. item no. item no. item no.
Type L 5,37 LX 04268992 04265992 04263992 04261992
Type K 4,10 KCA 04268994 04265994 04263994 04261994
Type R/S 0,65 R/SCB 04268996 04265996 04263996 04261996
Type U 4,25 UX 04268993 04265993 04263993 04261993
*Type B 0,00 BC-100 04268901 04265901 04263901 04261901
*Type B 0,033 BC-200 04268902 04265902 04263902 04261902
*Not standardized compensating cable for thermocouples type B with application temperatures up to 100C resp. 200 C.
C = compensating cables X = extension cables
Technical data:
Min. bending radius: 7.5 x d
Radiation resistance: 2 x 10
7
cJ/kg
Temperature range fixed laying: -40/+180 C
of insulation: flexible application: -25/+180 C
short-time use: -25/+250 C
Insulation resistance: > 1M x km
Halogen-free: acc. to DIN VDE 0472 part 815 and IEC 60754-1
Fire performance: flame retardant and self-extinguishing
acc. to IEC 60332-1-2 + EN 60332-1-2
Corrosiveness of in compliance with IEC 60754-2 +
conflagration gases: EN 50267-2-2 + VDE 0482 part 267-2-2 -
no development of corrosive conflagration gases
Absence of acc. to RoHS directive of the European Union
harmful substances: see page N/14
Construction:
Insulation: Besilen

EI 2 acc. to DIN EN 50363-1


Stranding: 2 cores together
Sheath: Besilen

EM9 acc. to DIN EN 50363-2-1


Shape: round
Conductor
construction: strand
Besilen

insulated cables A 15 L A 15-075 L A15-050 L A15-022 L


COMPENSATING AND
EXTENSION CABLES
L
14
A 3 Ln
A 4 Ln
q q
33
Type: A 3 Ln A 4 Ln
Conductor cross section: 1,5 mm
2
1,5 mm
2
Outer dimension: approx. 3,7 x 6,1 mm approx. 4,5 x 6,9 mm
Weight/100m: approx. 4,6 kg approx. 7,5 kg
DIN IEC 584
for thermocouple EMF at 100 C in mV cable type A 3 Ln A 4 Ln
item no. item no.
Type T 4,28 TX 04138958 04168958
Type J 5,27 JX 04138952 04168952
Type K 4,10 KCA 04138995 04168995
Type K 4,10 KCB 04138999 04168999
Type K 4,10 KX 04138954 04168954
Type E 6,32 EX 04138953 04168953
Type R/S 0,65 R/SCB 04138997 04168997
Type N 2,77 NC 04138991 04168991
DIN 43710/43714 (not valid for *type B)
for thermocouple EMF at 100 C in mV cable type A 3 Ln A 4 Ln
item no. item no.
Type L 5,37 LX 04138992 04168992
Type K 4,10 KCA 04138994 04168994
Type R/S 0,65 R/SCB 04138996 04168996
Type U 4,25 UX 04138998 04168998
*Type B 0,00 BC-100 04138901 04168901
*Type B 0,033 BC-200 04138902 04168902
We also manufacture compensating and extension cables colour coded to DIN VDE 43714 06/79
and the basic values laid down in DIN VDE 43710 which was withdrawn in April 1994.
*Not standardized compensating cable for thermocouples type B with application temperatures up to 100C resp. 200 C.
C = compensating cables X = extension cables
Technical data:
Min. bending radius: A 3 Ln: 10 x d
A 4 Ln: 12 x d
Radiation resistance: 2 x 10
7
cJ/kg
Temperature range fixed laying: -40/+180 C
of insulation: flexible application: -25/+180 C
short-time use: -25/+250 C
Insulation resistance: > 1M x km
Halogen-free: acc. to DIN VDE 0472 part 815 and IEC 60754-1
Fire performance: flame retardant and self-extinguishing
acc. to IEC 60332-1-2 + EN 60332-1-2
Corrosiveness of in compliance with IEC 60754-2 +
conflagration gases: EN 50267-2-2 + VDE 0482 part 267-2-2 -
no development of corrosive conflagration gases
Absence of acc. to RoHS directive of the European Union
harmful substances: see page N/14
Construction:
Insulation: Besilen

EI2 acc. to DIN EN 50363-1


Stranding: 2 cores parallel
Sheath: Besilen

EM9 acc. to DIN EN 50363-2-1


Armouring: A 4 Ln: tinned steel wire armouring
A 4 Ln: with tracer
Shape: oval
Conductor
construction: strand
Besilen

insulated cables A 3 Ln A 4 Ln with steel wire armouring


COMPENSATING AND
EXTENSION CABLES
Also available with
cross-sections
1,0 mm
2
, 0,75 mm
2
,
0,5 mm
2
and 0,22 mm
2
!
L
15
A 11 Lr A 11-4 Lr
A 11 Dr
q q
33
Type: A 11 Lr A 11-4 Lr A 11 Dr
Conductor cross section: 1,5 mm
2
1,5 mm
2
1,5 mm
2
Outer diameter: approx. 6,1 mm approx. 7,1 mm approx. 5,5 mm
Weight/100m: approx. 6,6 kg approx. 9,5 kg approx. 6,4 kg
DIN IEC 584
for thermocouple EMF at 100 C in mV cable type A 11 Lr A 11- 4 Lr A 11 Dr
item no. item no. item no.
Type T 4,28 TX 04218958 04210458 04238988
Type J 5,27 JX 04218952 04210452 04238982
Type K 4,10 KCA 04218995 04210495 04238915
Type K 4,10 KCB 04218999 04210499 04238919
Type K 4,10 KX 04218954 04210454 04238984
Type E 6,32 EX 04218953 04210453 04238983
Type R/S 0,65 R/SCB 04218997 04210497 04238917
Type N 2,77 NC 04218991 04210491 04238911
DIN 43710/43714 (not valid for *type B)
for thermocouple EMF at 100 C in mV cable type A 11 Lr A 11- 4 Lr A 11 Dr
item no. item no. item no.
Type L 5,37 LX 04218992 04210492 04238912
Type K 4,10 KCA 04218994 04210494 04238914
Type R/S 0,65 R/SCB 04218996 04210496 04238916
Type U 4,25 UX 04218998 04210498 04238918
*Type B 0,00 BC-100 04218901 04210401 04238921
*Type B 0,033 BC-200 04218902 04210402 04238922
We also manufacture compensating and extension cables colour coded to DIN VDE 43714 06/79
and the basic values laid down in DIN VDE 43710 which was withdrawn in April 1994.
*Not standardized compensating cable for thermocouples type B with application temperatures up to 100C resp. 200 C.
C = compensating cables X = extension cables
Technical data:
Min. bending radius: A 11 Lr, A11-4 Lr: 10 x d
A 11 Dr: 12 x d
Temperature range fixed laying: -40/+180 C
of insulation: flexible application: -25/+180 C
short-time use: -25/+250 C
Insulation resistance: > 1M x km
Halogen-free: acc. to DIN VDE 0472 part 815 and IEC 60754-1
Fire performance: flame retardant and self-extinguishing
acc. to IEC 60332-1-2 + EN 60332-1-2
Corrosiveness of in compliance with IEC 60754-2 +
conflagration gases: EN 50267-2-2 + VDE 0482 part 267-2-2 -
no development of corrosive conflagration gases
Absence of acc. to RoHS directive of the European Union
harmful substances: see page N/14
Construction:
Insulation: Besilen

EI2 acc. to DIN EN 50363-1


Stranding: 2 or 4 cores together
Braiding: fibre-glass with tracer
Armouring: galvanized steel wire armouring with tracer
Shape: round
Conductor
construction: strand resp. wire
Besilen

insulated cables
A 11 Lr A 11-4 Lr A 11 Dr
with fibre-glass braiding and steel wire armouring
COMPENSATING AND
EXTENSION CABLES
Also available with
cross-sections
1,0 mm
2
, 0,75 mm
2
,
0,5 mm
2
and 0,22 mm
2
!
L
16
A 13 L
q q
33
Type: A 13 L
Conductor cross section: 1,5 mm
2
Outer diameter: approx. 2,9 x 5,3 mm
Weight/100m: approx. 3,8 kg
DIN IEC 584
for thermocouple EMF at 100 C in mV cable type A 13 L
item no.
Type T 4,28 TX 04248958
Type J 5,27 JX 04248952
Type K 4,10 KCA 04248995
Type K 4,10 KCB 04248999
Type K 4,10 KX 04248954
Type E 6,32 EX 04248953
Type R/S 0,65 R/SCB 04248997
Type N 2,77 NC 04248991
DIN 43710/43714 (not valid for type B)
for thermocouple EMF at 100 C in mV cable type A 13 L
item no.
Type L 5,37 LX 04248992
Type K 4,10 KCA 04248994
Type R/S 0,65 R/SCB 04248996
Type U 4,25 UX 04248998
*Type B 0,00 BC-100 04248901
*Type B 0,033 BC-200 04248902
We also manufacture compensating and extension cables colour coded to DIN VDE 43714 06/79
and the basic values laid down in DIN VDE 43710 which was withdrawn in April 1994.
*Not standardized compensating cable for thermocouples type B with application temperatures up to 100C resp. 200 C.
C = compensating cables X = extension cables
Technical data:
Min. bending radius: 10 x d
Temperature range fixed laying: -40/+180 C
of insulation: flexible application: -25/+180 C
short-time use: -25/+250 C
Insulation resistance: > 1M x km
Halogen-free: acc. to DIN VDE 0472 part 815 and IEC 60754-1
Fire performance: flame retardant and self-extinguishing
acc. to IEC 60332-1-2 + EN 60332-1-2
Corrosiveness of in compliance with IEC 60754-2 +
conflagration gases: EN 50267-2-2 + VDE 0482 part 267-2-2 -
no development of corrosive conflagration gases
Absence of acc. to RoHS directive of the European Union
harmful substances: see page N/14
Construction:
Insulation: Besilen

EI2 acc. to DIN EN 50363-1


Stranding: parallel
Braiding: fibre-glass with tracer
Shape: oval
Conductor
construction: strand
Besilen

insulated cables A 13 L with fibre-glass braiding


COMPENSATING AND
EXTENSION CABLES
Also available with
cross-sections
1,0 mm
2
, 0,75 mm
2
,
0,5 mm
2
and 0,22 mm
2
!
L
17
A 6 L A 6-022 L
A 6 D
33
DIN IEC 584
DIN 43710/43714 (not valid for type B)
We also manufacture compensating and extension cables colour coded to DIN VDE 43714 06/79
and the basic values laid down in DIN VDE 43710 which was withdrawn in April 1994.
*Not standardized compensating cable for thermocouples type B with application temperatures up to 100C resp. 200 C.
C = compensating cables X = extension cables
Technical data:
Min. bending radius: A 6 L: 7.5 x d
A 6 D: 12 x d
Radiation resistance: 2 x 10
7
cJ/kg
Temperature range fixed laying: -40/+180 C
of insulation: flexible application: -25/+180 C
short-time use: -25/+250 C
Insulation resistance: > 1M x km
Halogen-free: acc. to DIN VDE 0472 part 815 and IEC 60754-1
Fire performance: flame retardant and self-extinguishing
acc. to IEC 60332-1-2 + EN 60332-1-2
Corrosiveness of in compliance with IEC 60754-2 +
conflagration gases: EN 50267-2-2 + VDE 0482 part 267-2-2 -
no development of corrosive conflagration gases
Absence of acc. to RoHS directive of the European Union
harmful substances: see page N/14
Construction:
Insulation: Besilen

EI2 acc. to DIN EN 50363-1


Stranding: 2 cores together
Wrapping: PETP foil with bare copper earth wire
0,5 mm
Screen: Alu-foil
Sheath: Besilen

EM9 acc. to DIN EN 50363-2-1


Shape: round
Conductor
construction: strand resp. wire
Besilen

insulated cables A 6 L A 6-022 L A 6 D


COMPENSATING AND
EXTENSION CABLES
w
ith
A
lu
-
fo
il
s
c
r
e
e
n
Type: A 6 L A 6-022 L A 6 D
Conductor cross section: 1,5 mm
2
0,22 mm
2
1,5 mm
2
Outer diameter: approx. 7,0 mm approx. 4,0 mm approx. 6,4 mm
Weight/100m: approx. 6,1 kg approx. 1,9 kg approx. 5,7 kg
for thermocouple EMK at cable type A 6 L A 6-022 L A 6 D
100 C in mV item no. item no. item no.
Type T 4,28 TX 04288958 04285958 04283958
Type J 5,27 JX 04288952 04285952 04283952
Type K 4,10 KCA 04288995 04285995 04283995
Type K 4,10 KCB 04288999 04285999 04283999
Type K 4,10 KX 04288954 04285954 04283954
Type E 6,32 EX 04288953 04285953 04283953
Type R/S 0,65 R/SCB 04288997 04285997 04283997
Type N 2,77 NC 04288991 04285991 04283991
for thermocouple EMK at cable type A 6 L A 6-022 L A 6 D
100 C in mV item no. item no. item no.
Type L 5,37 LX 04288992 04285992 04283992
Type K 4,10 KCA 04288994 04285994 04283994
Type R/S 0,65 R/SCB 04288996 04285996 04283996
Type U 4,25 UX 04288998 04285998 04283998
*Type B 0,00 BC-100 04288901 04285901 04283901
*Type B 0,033 BC-200 04288902 04285902 04283902
L
18
A 15 LC A 15-075 LC A 15-050 LC A 15-022 LC
33
DIN IEC 584
DIN 43710/43714 (not valid for type B)
We also manufacture compensating and extension cables colour coded to DIN VDE 43714 06/79
and the basic values laid down in DIN VDE 43710 which was withdrawn in April 1994.
*Not standardized compensating cable for thermocouples type B with application temperatures up to 100C resp. 200 C.
C = compensating cables X = extension cables
Technical data:
Min. bending radius: 12 x d
Radiation resistance: 2 x 10
7
cJ/kg
Temperature range fixed laying: -40/+180 C
of insulation: flexible application: -25/+180 C
short-time use: -25/+250 C
Insulation resistance: > 1M x km
Halogen-free: acc. to DIN VDE 0472 part 815 and IEC 60754-1
Fire performance: flame retardant and self-extinguishing
acc. to IEC 60332-1-2 + EN 60332-1-2
Corrosiveness of in compliance with IEC 60754-2 +
conflagration gases: EN 50267-2-2 + VDE 0482 part 267-2-2 -
no development of corrosive conflagration gases
Absence of acc. to RoHS directive of the European Union
harmful substances: see page N/14
Construction:
Insulation: Besilen

EI2 acc. to DIN EN 50363-1


Stranding: 2 cores together
Wrapping: PETP foil
Screen: tinned copper braiding
Sheath: Besilen

EM9 acc. to DIN EN 50363-2-1


Shape: round
Conductor
construction: strand
Besilen

insulated cables A 15 LC A 15-075 LC A 15-050 LC A 15-022 LC


COMPENSATING AND
EXTENSION CABLES
w
ith
o
v
e
r
a
ll
c
o
p
p
e
r
s
c
r
e
e
n
Type: A 15 LC A 15-075 LC A 15-050 LC A 15-022 LC
Conductor cross section: 1,5 mm
2
0,75 mm
2
0,50 mm
2
0,22 mm
2
Outer diameter: approx. 6,8 mm approx. 5,7 mm approx. 5,1 mm approx. 3,8 mm
Weight/100m: approx. 7,0 kg approx. 4,6 kg approx. 3,6 kg approx. 2,1 kg
for thermocouple EMK at cable type A 15 LC A 15-075 LC A 15-050 LC A 15-022 LC
100 C in mV item no. item no. item no. item no.
Type T 4,28 TX 04308958 04305958 04303958 04301958
Type J 5,27 JX 04308952 04305952 04303952 04301952
Type K 4,10 KCA 04308995 04305995 04303995 04301995
Type K 4,10 KCB 04308999 04305999 04303999 04301999
Type K 4,10 KX 04308954 04305954 04303954 04301954
Type E 6,32 EX 04308953 04305953 04303953 04301953
Type R/S 0,65 R/SCB 04308997 04305997 04303997 04301997
Type N 2,77 NC 04308991 04305991 04303991 04301991
for thermocouple EMK at cable type A 15 LC A 15-022 LC A 15-022 LC A 15-022 LC
100 C in mV item no. item no. item no. item no.
Type L 5,37 LX 04308992 04305992 04303992 04301992
Type K 4,10 KCA 04308994 04305994 04303994 04301994
Type R/S 0,65 R/SCB 04308996 04305996 04303996 04301996
Type U 4,25 UX 04308998 04305998 04303998 04301998
*Type B 0,00 BC-100 04308901 04305901 04303901 04301901
*Type B 0,033 BC-200 04308902 04305902 04303902 04301902
L
19
A 15-022
A 15-G 022
33
Type: A 15-022 A 15-G 022
Conductor cross section: 0,22 mm
2
0,22 mm
2
Outer diameter/dim.: approx. 2,9 mm approx. 3,4 mm
Weight/100m: approx. 1,1 kg approx. 1,7 kg
DIN IEC 584
for thermocouple EMF at 100 C in mV cable type A 15-022 A 15-G 022
item no. item no.
Type T 4,28 TX 04511958 04521958
Type J 5,27 JX 04511952 04521952
Type K 4,10 KCA 04511995 04521995
Type K 4,10 KCB 04511999 04521999
Type K 4,10 KX 04511954 04521954
Type E 6,32 EX 04511953 04521953
Type R/S 0,65 R/SCB 04511997 04521997
Type N 2,77 NC 04511991 04521991
DIN 43710/43714 (not valid for type B)
for thermocouple EMF at 100 C in mV cable type A 15-022 A 15-G 022
item no. item no.
Type L 5,37 LX 04511992 04521992
Type K 4,10 KCA 04511994 04521994
Type R/S 0,65 R/SCB 04511996 04521996
Type U 4,25 UX 04511998 04521998
*Type B 0,00 BC-100 04511901 04521901
*Type B 0,033 BC-200 04511902 04521902
We also manufacture compensating and extension cables colour coded to DIN VDE 43714 06/79
and the basic values laid down in DIN VDE 43710 which was withdrawn in April 1994.
*Not standardized compensating cable for thermocouples type B with application temperatures up to 100C resp. 200 C.
C = compensating cables X = extension cables
Technical data:
Min. bending radius: 7.5 x d
Temperature range fixed laying: -40/+180 C
of insulation: flexible application: -25/+180 C
short-time use: -25/+250 C
Halogen-free: acc. to DIN VDE 0472 part 815 and IEC 60754-1
Fire performance: flame retardant and self-extinguishing
acc. to IEC 60332-1-2 + EN 60332-1-2
Corrosiveness of in compliance with IEC 60754-2 +
conflagration gases: EN 50267-2-2 + VDE 0482 part 267-2-2 -
no development of corrosive conflagration gases
Absence of acc. to RoHS directive of the European Union
harmful substances: see page N/14
Construction:
Insulation: fibre-glass
Stranding: 2 cores together
Sheat material: Besilen

EM9 acc. to DIN EN 50363-2-1


Braiding: A15-G 022:
fibre-glass with tracer
Shape: round
Conductor
construction: strand
Fibre-glass insulated cables
A 15-022
A 15-G 022 with outer fibre-glass braiding
COMPENSATING AND
EXTENSION CABLES
L
20
A 3 L
A 4 L
33
Type: A 3 L A 4 L
Conductor cross section: 1,5 mm
2
1,5 mm
2
Outer dimension: approx. 4,6 x 6,8 mm approx. 5,4 x 7,6 mm
Weight/100m: approx. 5,4 kg approx. 7,8 kg
DIN IEC 584
for thermocouple EMF at 100 C in mV cable type A 3 L A 4 L
item no. item no.
Type T 4,28 TX 04128958 04158958
Type J 5,27 JX 04128952 04158952
Type K 4,10 KCA 04128995 04158995
Type K 4,10 KCB 04128999 04158999
Type K 4,10 KX 04128954 04158954
Type E 6,32 EX 04128953 04158953
Type R/S 0,65 R/SCB 04128997 04158997
Type N 2,77 NC 04128991 04158991
DIN 43710/43714 (not valid for type B)
for thermocouple EMF at 100 C in mV cable type A 3 L A 4 L
item no. item no.
Type L 5,37 LX 04128992 04158992
Type K 4,10 KCA 04128994 04158994
Type R/S 0,65 R/SCB 04128996 04158996
Type U 4,25 UX 04128998 04158998
*Type B 0,00 BC-100 04128901 04158901
*Type B 0,033 BC-200 04128902 04158902
We also manufacture compensating and extension cables colour coded to DIN VDE 43714 06/79
and the basic values laid down in DIN VDE 43710 which was withdrawn in April 1994.
*Not standardized compensating cable for thermocouples type B with application temperatures up to 100C resp. 200 C.
C = compensating cables X = extension cables
Technical data:
Min. bending radius: A 3 L: 10 x d
A 4 L: 12 x d
Temperature range fixed laying: -50/+200 C
of insulation: flexible application: -50/+200 C
short-time use: -50/+300 C
Halogen-free: acc. to DIN VDE 0472 part 815 and IEC 60754-1
Fire performance: no flame propagation acc. to IEC 60332 +
EN 60332 Cat. C resp. D (see page N/20).
Flame retardant and self-extinguishing
IEC 60332-1-2 + EN 60332-1-2.
Corrosiveness of in compliance with IEC 60754-2 +
conflagration gases: EN 50267-2-2 + VDE 0482 part 267-2-2 -
no development of corrosive conflagration gases
Smoke density: low (low smoke emission)
Absence of acc. to RoHS directive of the European Union
harmful substances: see page N/14
Construction:
Insulation: fibre-glass
Stranding: 2 cores parallel
Braiding: Stex with tracer
Armouring: A 4 L: galvanized steel wire armouring
A 4 L: with tracer
Shape: oval
Conductor
construction: strand
Fibre-glass insulated cables A 3 L A 4 L with steel wire armouring
COMPENSATING AND
EXTENSION CABLES
w
ith
B
te
x
b
r
a
id
in
g
L
21
A 18 L A 18-022 L
A 19 L A 19-022 L
33
Type: A 18 L A 18-022 L A 19 L A 19-022 L
Conductor cross section: 1,5 mm
2
0,22 mm
2
1,5 mm
2
0,22 mm
2
Outer diameter: approx. 4,8 mm approx. 2,5 mm approx. 5,4 mm approx. 3,0 mm
Weight/100m: approx. 4,2 kg approx. 1,0 kg approx. 5,6 kg approx. 1,9 kg
for thermocouple EMK at cable type A 18 L A 18-022 L A 19 L A 19-022 L
100 C in mV item no. item no. item no. item no.
Type T 4,28 TX 04338958 04331958 04358958 04351958
Type J 5,27 JX 04338952 04331952 04358952 04351952
Type K 4,10 KCA 04338995 04331995 04358995 04351995
Type K 4,10 KCB 04338999 04331999 04358999 04351999
Type K 4,10 KX 04338954 04331954 04358954 04351954
Type E 6,32 EX 04338953 04331953 04358953 04351953
Type R/S 0,65 R/SCB 04338997 04331997 04358997 04351997
Type N 2,77 NC 04338991 04331991 04358991 04351991
for thermocouple EMK at cable type A 18 L A 18-022 L A 19 L A 19-022 L
100 C in mV item no. item no. item no. item no.
Type L 5,37 LX 04338992 04331992 04358992 04351992
Type K 4,10 KCA 04338994 04331994 04358994 04351994
Type R/S 0,65 R/SCB 04338996 04331996 04358996 04351996
Type U 4,25 UX 04338998 04331998 04358998 04351998
*Type B 0,00 BC-100 04338901 04331901 04358901 04351901
*Type B 0,033 BC-200 04338902 04331902 04358902 04351902
DIN IEC 584
DIN 43710/43714 (not valid for type B)
We also manufacture compensating and extension cables colour coded to DIN VDE 43714 06/79
and the basic values laid down in DIN VDE 43710 which was withdrawn in April 1994.
*Not standardized compensating cable for thermocouples type B with application temperatures up to 100C resp. 200 C.
C = compensating cables X = extension cables
Technical data:
Min. bending radius: 12 x d
Radiation resistance: 1 x 10
7
cJ/kg
Temperature range fixed laying: -90/+180 C
of insulation: flexible application: -55/+180 C
Insulation resistance: > 1M x km
Fire performance: no flame propagation acc. to IEC 60332 +
EN 60332 Cat. C resp. D (see page N/20).
Flame retardant and self-extinguishing
IEC 60332-1-2 + EN 60332-1-2.
Chem. resistance: very good against fats, oils, salts and acids
Absence of acc. to RoHS directive of the European Union
harmful substances: see page N/14
Construction:
Insulation: FEP
Stranding: 2 cores together
Wrapping: A 18 L, A 18-022 L: PETP foil
Screen: A 19 L, A 19-022 L: tinned copper braiding
Sheath: FEP
Shape: round
Conductor
construction: strand
FEP insulated cables
A 18 L A 18-022 L
A 19 L A 19-022 L with overall copper screen
COMPENSATING AND
EXTENSION CABLES
Th LGS Th LRS
L
22
33
Thermocouple code see page L/5
Type: Th LGS Th LRS
Conductor 0,22 mm
2
= 7 x 0,20 mm 0,22 mm
2
= 7 x 0,20 mm
construction:

0,50 mm
2
= 16 x 0,20 mm 0,50 mm
2
= 16 x 0,20 mm
1,00 mm
2
= 32 x 0,20 mm 1,00 mm
2
= 32 x 0,20 mm
item no. type no. of cores for approx. approx. cable
x cross section thermo- outer- weight
n x mm
2
couple mm kg/100 m
047110* Th 20 LGS 2 x 0,22 Fe-CuNi 3,1 2,0
047111* Th 50 LGS 2 x 0,50 Fe-CuNi 3,7 3,9
047112* Th 100 LGS 2 x 1,00 Fe-CuNi 4,5 4,3
047113* Th 20-4 LGS 4 x 0,22 Fe-CuNi 3,5 2,9
047114* Th 50-4 LGS 4 x 0,50 Fe-CuNi 4,2 4,3
047115* Th 100-4 LGS 4 x 1,00 Fe-CuNi 5,4 7,0
047110* Th 20 LGS 2 x 0,22 NiCr-Ni 3,1 2,0
047111* Th 50 LGS 2 x 0,50 NiCr-Ni 3,7 3,2
047112* Th 100 LGS 2 x 1,00 NiCr-Ni 4,5 4,3
047113* Th 20-4 LGS 4 x 0,22 NiCr-Ni 3,5 2,9
047114* Th 50-4 LGS 4 x 0,50 NiCr-Ni 4,2 4,3
047115* Th 100-4 LGS 4 x 1,00 NiCr-Ni 5,4 7,0
item no. type no. of cores for approx. approx. cable
x cross section thermo- outer- weight
n x mm
2
couple mm kg/100 m
047210* Th 20 LRS 2 x 0,22 Fe-CuNi 3,1 1,9
047211* Th 50 LRS 2 x 0,50 Fe-CuNi 3,7 3,9
047212* Th 100 LRS 2 x 1,00 Fe-CuNi 4,5 5,2
047213* Th 20 -4 LRS 4 x 0,22 Fe-CuNi 3,5 2,9
047214* Th 50 -4 LRS 4 x 0,50 Fe-CuNi 4,2 5,1
047215* Th 100-4 LRS 4 x 1,00 Fe-CuNi 5,4 7,5
047210* Th 20 LRS 2 x 0,22 NiCr-Ni 3,1 1,9
047211* Th 50 LRS 2 x 0,50 NiCr-Ni 3,7 3,9
047212* Th 100 LRS 2 x 1,00 NiCr-Ni 4,5 5,2
047213* Th 20 -4 LRS 4 x 0,22 NiCr-Ni 3,5 2,9
047214* Th 50 -4 LRS 4 x 0,50 NiCr-Ni 4,2 5,1
047215* Th 100-4 LRS 4 x 1,00 NiCr-Ni 5,4 7,5
Th LGS Th LRS
Technical data:
Min. bending radius: 12 x d
Temperature range Th LGS: max. 250 C
of insulation: Th LRS: max. 400 C
Halogen-free: acc. to DIN VDE 0472 part 815 and IEC 60754-1
Fire performance: no flame propagation acc. to IEC 60332 +
EN 60332 Cat. C resp. D (see page N/20).
Flame retardant and self-extinguishing
IEC 60332-1-2 + EN 60332-1-2.
Absence of acc. to RoHS directive of the European Union
harmful substances: see page N/14
Construction:
Core insulation: Th LGS: fibre-glass
Th LRS: special fibre-glass
Stranding: cores together
Braiding: Th LGS: fibre-glass
Th LRS: special fibre-glass
Armouring: galvanized steel wire armouring with tracer
Shape: round
Fibre-glass insulated extension cables
for thermocouples
Th LGS with fibre-glass braiding and steel wire armouring
Th LRS with special fibre-glass braiding and steel wire armouring
COMPENSATING AND
EXTENSION CABLES
Th LTS
Th LTV
L
23
33
Thermocouple code see page L/5
item no. type no. of cores for approx. approx. cable
x cross section thermo- outer- weight
n x mm
2
couple mm kg/100 m
047310* Th 20 LTS 2 x 0,22 Fe-CuNi 3,3 2,1
047311* Th 50 LTS 2 x 0,50 Fe-CuNi 4,1 3,9
047312* Th 100 LTS 2 x 1,00 Fe-CuNi 4,9 5,2
047313* Th 20-4 LTS 4 x 0,22 Fe-CuNi 3,7 3,2
047314* Th 50-4 LTS 4 x 0,50 Fe-CuNi 4,7 5,1
047315* Th 100-4 LTS 4 x 1,00 Fe-CuNi 5,6 7,5
047310* Th 20 LTS 2 x 0,22 NiCr-Ni 3,3 2,1
047311* Th 50 LTS 2 x 0,50 NiCr-Ni 4,1 3,9
047312* Th 100 LTS 2 x 1,00 NiCr-Ni 4,9 5,2
047313* Th 20-4 LTS 4 x 0,22 NiCr-Ni 3,7 3,2
047314* Th 50-4 LTS 4 x 0,50 NiCr-Ni 4,7 5,1
047315* Th 100-4 LTS 4 x 1,00 NiCr-Ni 5,6 7,5
item no. type no. of cores for approx. approx. cable
x cross section thermo- outer- weight
n x mm
2
couple mm kg/100 m
047350* Th 20 LTV 2 x 0,22 Fe-CuNi 3,2 1,9
047351* Th 50 LTV 2 x 0,5 Fe-CuNi 4,1 3,9
047352* Th 100 LTV 2 x 1,0 Fe-CuNi 4,9 5,2
047353* Th 20 -4 LTV 4 x 0,22 Fe-CuNi 3,6 2,9
047354* Th 50 -4 LTV 4 x 0,5 Fe-CuNi 4,7 5,1
047355* Th 100-4 LTV 4 x 1,0 Fe-CuNi 5,6 7,5
047350* Th 20 LTV 2 x 0,22 NiCr-Ni 3,2 1,9
047351* Th 50 LTV 2 x 0,5 NiCr-Ni 4,1 3,9
047352* Th 100 LTV 2 x 1,0 NiCr-Ni 4,9 5,2
047353* Th 20 -4 LTV 4 x 0,22 NiCr-Ni 3,6 2,9
047354* Th 50 -4 LTV 4 x 0,5 NiCr-Ni 4,7 5,1
047355* Th 100-4 LTV 4 x 1,0 NiCr-Ni 5,6 7,5
Th LTS Th LTV
Technical data:
Min. bending radius: 12 x d
Temperature range
of insulation:
flexible application: max. +250 C
fixed laying: max. +250 C
limited time of use: max. +260 C
Insulation resistance: > 1M x km
Fire performance: no flame propagation acc. to IEC 60332 +
EN 60332 Cat. C resp. D (see page N/20).
Flame retardant and self-extinguishing
IEC 60332-1-2 + EN 60332-1-2.
Absence of acc. to RoHS directive of the European Union
harmful substances: see page N/14
Construction:
Insulation: PFA
Stranding: cores together
Braiding: fibre-glass
Armouring: Th LTS: galvanized steel wire armouring
with tracer
Th LTV: stainless steel wire armouring (VA)
with tracer
Shape: round
PFA insulated extension cables
for thermocouples
Th LTS with steel wire armouring
Th LTV stainless steel wire armouring
COMPENSATING AND
EXTENSION CABLES
Type: Th LTS Th LTV
Conductor 0,22 mm
2
= 7 x 0,20 mm 0,22 mm
2
= 7 x 0,20 mm
construction:
0,50 mm
2
= 16 x 0,20 mm 0,50 mm
2
= 16 x 0,20 mm
1,00 mm
2
= 32 x 0,20 mm 1,00 mm
2
= 32 x 0,20 mm
TGV
L
24
33
item no. no. of cores construction approx. approx. cable
x cross section of strands outer- weight
n x mm
2
n x wire mm kg/km
04700218 2 x 0,18 10 x 0,15 3,4 2,1
04700318 3 x 0,18 10 x 0,15 3,6 2,3
04700418 4 x 0,18 10 x 0,15 4,0 2,7
04700618 6 x 0,18 10 x 0,15 4,8 3,8
Bcolour code:
2-cores red-white
3-cores red-red-white
4-cores red-red-white-white
6-cores red-red-white-white-black-black
TGV
Technical data:
Min. bending radius: 12 x d
Temperature range
of insulation:
flexible application: max. +250 C
fixed laying: max. +250 C
limited time of use: max. +260 C
Insulation resistance: > 1M x km
Fire performance: no flame propagation acc. to IEC 60332 +
EN 60332 Cat. C resp. D (see page N/20).
Flame retardant and self-extinguishing
IEC 60332-1-2 + EN 60332-1-2.
Absence of acc. to RoHS directive of the European Union
harmful substances: see page N/14
Construction:
Conductor: nickel-plated copper strands
Insulation: PFA
Braiding: fibre-glass
Stranding: cores together
Armouring: stainless steel wire armouring (VA)
with tracer
Shape: round
PFA insulated connection cables
for resistance thermometers
TGV with fibre-glass braiding and
stainless steel wire armouring
COMPENSATING AND
EXTENSION CABLES
L
25
q
Connection cables for resistance thermometers,
special and hybrid cables
COMPENSATING AND
EXTENSION CABLES
For all cables
possible on request:
heat resistant PVC
up to +105C
notch resistant
Besilen

sheath (EWKF)
S
identification
Figure Insulation Cross section Outer
diameter
Temperature range
of insulation
Connection cables for resistance thermometers
TTL PFA 0,12 - 0,18 mm
2
2,3 - 2,5 mm
fixed laying:
max. +250C
limited time of use:
max. +260C
Th LTS
Th LTV
fibre-glass/
fibre-glass
0,18 mm
2
2,9 mm
fixed laying:
max. +250C
LiYY
LiYCY
BiHF-J
BiHF/Cu/Bi-J
PVC
Besilen

0,14 - 1,5 mm
2
3,1 - 8,4 mm
3,6 - 9,3 mm
(braid)
4,3 - 18,6 mm
6,4 - 17,0 mm
(braid)
fixed laying:
-30C to +70C
fixed laying:
-40C to +180C
TGV
PFA
fibre-glass
(braid)
0,18 mm
2
3,4 - 4,8 mm
fixed laying:
+250C
Special and hybrid cables
S
Type
Figure Insulation Cross section Outer
diameter
Temperature range
of insulation
Type J
***
Core: PVC
Sheath:
PUR
3 x 2 x 0,5 mm
2
JX
+ 8 x 6 mm
2
18,8 mm
fixed laying:
-25C to +70C
Type K
Type J
Type L
***
Core: TPE
Sheath:
PUR
0,22 mm
2
3,0 mm
flexible application:
-40C to +90C
Type K
Type J
Type L
***
PI-foil
PI-foil
0,20 mm
2
0,9 x 0,5 mm
fixed laying:
-40C to +250C
q
particularly appropriate
for helix cables
*** Type T, E, R/S, N on request!
possible!
L
26
Compensating and Extension Cables
for the automotive industry
COMPENSATING AND
EXTENSION CABLES
S
item no.
Picture Cable type T/C
type
Insu -
lation
Section Cond. Form Outer- Temp.-range of
insulation
thermo electric
voltage
fibre-glass insulated thermo-cables (wire)
0489-9002 thermo -
cable
type K GL/GL 2 x 0,2 mm wire oval approx.
0,8 x 1,3 mm
flexible:
-25C up to +200C
fixed:
-25C up to +200C
DIN IEC
584
class 1,
tolerance
+/- 1,5C
0489-2144 thermo-
couple -
cable
type K GL/GL 2 x 0,5 mm wire oval approx.
1,9 x 1,1 mm
flexible:
-40C up to +250C
fixed:
-40C up to +250C
DIN IEC
584
class 1
0489-9003 thermo -
cable
type K GL/GL 2 x 0,8 mm wire oval approx.
2,5 x 1,4 mm
flexible:
-25C up to +200C
fixed:
-25C up to +200C
DIN IEC
584
class 1
0490-9016 thermo-
couple -
cable
type K GL/GL 2 x 0,5 mm wire oval approx.
2,0 x 1,2 mm
flexible:
max. +400C
fixed:
max. +400C
DIN IEC
584
class 1
polyimide insulated thermo-cables (wire)
0433-9138 thermo-
couple -
cable
type K KN-Polyi-
mid
KP-blank/
Polyimid
2 x 0,2 mm wire oval approx.
0,9 x 0,5 mm
flexible:
-40C up to +250C
fixed:
-40C up to +250C
DIN IEC
584
class 1,
tolerance
+/- 1,5C
0433-9186 thermo-
couple -
cable
type K KN-Polyi-
mid
KP-blank/
Polyimid
2 x 0,2 mm wire oval approx.
0,7 x 0,5 mm
flexible:
-40C up to +250C
fixed:
-40C up to +250C
DIN IEC
584
class 1,
tolerance
+/- 1,5C
0433-9149 thermo-
couple -
cable
type K Polyimid +
PTFE/
Polyimid
2 x 0,3 mm wire oval approx.
0,9 x 1,7 mm
flexible:
-40C up to +250C
fixedt:
-40C up to +250C
DIN IEC
584
class 1,
tolerance
+/- 1,5C
0433-9168 thermo-
couple -
cable
type K KN-Polyi-
mid
KP-PTFE/
Polyimid
2 x 0,2 mm wire oval approx.
1,0 x 0,8 mm
flexible:
-40C up to +250C
fixed:
-40C up to +250C
DIN IEC
584
class 1
polyimide/PFA insulated thermo-cables (wire)
0433-9196 thermo-
couple -
cable
type K KN-Polyi-
mid
KP blank/
Polyimid/
PFA
2 x 0,2 mm wire round max. 1,0 mm flexible:
-40C up to +250C
fixed:
-40C up to +250C
DIN IEC
584
class 1
FEP insulated thermo-cables (wire)
0433-9152 thermo-
couple -
cable
type K FEP/FEP 2 x 0,2 mm wire oval approx.
1,7 x 1,1 mm
flexible:
-40C up to +180C
fixed:
-40C up to +180C
DIN IEC
584
class 1
TPE insulated thermo-cable (strands)
0433-9177 thermo-
couple -
cable
type K TPE/TPE 2 x 0,2 mm
2
strands round approx.
3,0 mm
flexible:
-40C up to +90C
fixed:
-40C up to +90C
DIN IEC
584
class 1
FEP/Besilen

insulated thermo-cables (strands)


0433-9193 thermo -
cable
type K FEP/FEP/
Bi
2 x 0,2 mm
2
strands round approx.
3,8 mm
flexible:
-25C up to +180C
fixed:
-40C up to +180C
DIN IEC
584
class 2
L
27
Compensating and Extension Cables
for the automotive industry
COMPENSATING AND
EXTENSION CABLES
S
item no.
Picture Cable type T/C
type
Insu -
lation
Section Cond. Form Outer- Temp.-range of
insulation
thermo electric
voltage
FEP/Besilen

connection cables for resistance thermometers (strands)


0470-9224 connection
cable
tinned
copper
strands
copper
figure:
2,7
kg/km
FEP/Bi 2 x 0,14 mm
2
strands round approx.
2,8 mm
flexible:
-25C up to +180C
fixed:
-40C up to +180C
0470-0423 connection
cable
tinned
copper
strands
copper
figure:
8,4
kg/km
FEP/Bi 4 x 0,22 mm
2
strands round approx.
3,9 mm
flexible:
-25C up to +180C
fixed:
-40C up to +180C
3833-9132 connection
cable
tinned
copper
strands
copper
figure:
19,3
kg/km
FEP/C/
FEP
4 x 0,22 mm
2
strands round approx.
3,0 mm
flexible:
-55C up to +180C
fixed:
-90C up to +180C
FEP insulated thermo-cables (strands)
0433-9157 thermo -
cable
type K FEP/FEP 2 x 0,22 mm
2
strands oval approx.
2,5 x 1,5 mm
flexible:
-25C up to +180C
fixed:
-25C up to +180C
DIN IEC
584,
tolerance
+/- 1C
0433-9137 thermo -
cable
type K FEP/FEP 2 x 0,22 mm
2
strands round approx.
2,0 mm
flexible:
-25C up to +180C
fixed:
-25C up to +180C
DIN IEC
584,
tolerance
+/- 1C
0433-9154 thermo -
cable
type K FEP/FEP 8 x 2 x
0,22 mm
2
strands round approx.
6,4 mm
flexible:
-25C up to +180C
fixed:
-25C up to +180C
DIN IEC
584
class 2
0433-9135 thermo -
cable
type K FEP/FEP 16 x 2 x
0,22 mm
2
twisted pairs
strands round approx.
7,7 mm
flexible:
-25C up to +180C
fixed:
-25C up to +180C
DIN IEC
584
class 2
0435-9085 thermo-
couple -
cable
type K FEP-F-ZF-
D(B)-
FEP/F-C
(B)-FEP
8 x
(2 x 0,5 mm)D
strands round approx.
11,0 mm
flexible:
-55C up to +180C
fixed:
-90C up to +180C
DIN IEC
584
class 1
FEP insulated thermo-cables with screening (strands)
0435-9037 thermo -
cable
type K FEP/C/
FEP
2 x 0,22 mm
2
strands round approx.
2,6 mm
flexible:
-25C up to +180C
fixed:
-25C up to +180C
DIN IEC
584,
tolerance
+/- 1,5C
Besilen

insulated thermo-cables (strands)


0451-9019 thermo -
cable
type K GL/
Silicone
2 x 0,22 mm
2
strands round approx.
3,2 mm
flexible:
-25C up to +200C
fixed:
-25C up to +200C
DIN IEC
584
class 1
Ni Cr Si - Ni Si
Pt Rh 13 - Pt
Pt Rh 10 - Pt
Pt Rh 30 -
Pt Rh 6
N
R
S
B
Fe - Cu Ni
Ni Cr - Cu Ni
Ni Cr - Ni
Ni Cr - Ni
Ni Cr - Ni
L
E
K
K
K
T Cu - Cu Ni
Cu - Cu Ni
Fe - Cu Ni
U
J
DIN 43710* ANSI MC 96.1 BS 4937 NF C 42-324 DIN IEC 584
L
28
Colour code and temperature range
for compensating and extension cables
COMPENSATING AND
EXTENSION CABLES
THERMOCOUPLE
Code
NX NC
-25 to 0 to
+200C +150C
TX
-25 to +100C
0 to +100C 0 to +100C -25 to +200C
UX
0 to +200C
JX
-25 to +200C 0 to +200C 0 to +200C -25 to +200C
LX
0 to +200C
EX
-25 to +200C 0 to +200C 0 to +200C -25 to +200C
KX
-25 to +200C 0 to +200C 0 to +200C -25 to +200C
KCA
0 to +150C 0 to +150C
KCB
0 to +100C 0 to +100C 0 to +100C
RCB/
SCB
0 to +200C 0 to +200C 0 to +200C 0 to +200C
0 to +100C 0 to +100C
Material
Identification
THL AGL
Identification
THL AGL
Identification
THL AGL
Identification
THL AGL
Identification
THL AGL
The application temperature range of the cable is limited by the highest application temperature of the insulating material or the application temperature range of the conductor material. In all cases the
respective lower figure is valid. The compensating cable for the thermocouple type B can also be manufactured, deviating from the corresponding standards, for a temperature range from 0 to +200C
(S-Type BC-200). Variant colour codes can be manufactured for a minimum order quantity.
* The standard 43710 was withdrawn in April 1994. THL = extension cable AGL = compensating cable
* Therefore, the element types U and L are not standardized anymore.