Sectional Door Double-Skinned Type SW
Teckentrup
optionally with wicket door
Text example
Compile and tender according
to requirements.
Please refer to Technical Data
below for respective details.
Updated 01.07.2013
Position
No. of
pieces
Item
Unit price
Total price
Sectional door double-skinned PUR foam core. Building depth 40 mm. Outer surface stucco design. Inner
surface stucco design. Colour similar to RAL 9002
(grey white). Slide bolt for side locking into the frame
including handle on the inside. Sections with centre
seal. EPDM header seal and floor seal and lateral protective strip. Screwed hinges made of galvanized steel,
lateral roller guide with adjustable ball bearing rollers.
Weight compensation with torsion spring shaft with
lateral load-bearing cables. Teckentrup or equivalent.
Ordering dimensions:
Clearance dimensions: ___mm wide and ___mm high are = clear opening dimensions
Ordering details:
Headroom: ___mm
Lateral buffer right-hand ___mm, left-hand ___mm (for clearance refer to special
equipment)
With/without wicket door
Special equipment:
Additional basic coating in accordance with RAL (factory coated).
Glazing frame powder-coated in accordance with RAL
Technical data
Product:
Sectional door SW Performance values in acc. with
the new door product standard EN 13241-1
Heat insulation U-value (test in acc. with EN ISO 12567-1):
U = 0.56 W/mk (door panel 40 mm)
U = 1.7 W/mk (complete door without wicket door)
U = 0.95 W/mk (only door leaf without wicket door)
U = 1.9 W/mk (only door leaf with wicket door)
Air permeability (test in acc. with EN 12427, classification
in acc. with EN 12426):
Class 3
(without wicket door)
(with wicket door and single/ multiple
Class 3
locking mechanism)
Resistance to wind load (test in acc. with EN 12444,
classification in acc. with EN 12424):
(max. 700 N/m) (without wicket door)
Class 3
Class 3
(max. 700 N/m) (with wicket door and
single / multiple locking mechanism)
Resistance to water penetration (test in acc. with EN
12489, classification in acc. with EN 12425):
(without wicket door)
Class 2/3*1
(with wicket door)
Class 1/3*1
1
* Can only be achieved with special bottom profiles.
Reaction to fire (DIN EN 4102):
Door leaf element. Material class B2 (normally inflammable)
Installation in: Masonry
Concrete
Autoclaved aerated concrete
Steel construction
Dimensions:
Width: 2250 7800 mm; Height: 1875 6000 mm
(other dimensions on request)
Door leaf:
Door leaf consisting of individual door sections,
Galvanized sheet steel; building depth: 40 mm
Insulation: Polyurethane foam core
1
Surface:
Panels horizontally ribbed outside, stucco textured or microprofiled, inside stucco textured, Including centre seal
Sealed door edges due to:
EPDM upper header seal and floor seal
Fittings:
Screwed hinges, galvanized (connect the individual sections)
Lateral roller guide with adjustable rollers on ball bearings
(door positioned horizontally via runner rail curves)
Frame:
Profile frame, hot-dip galvanized. Protective strip with
EPDM sealing lip, on both sides
Manual
operation:
Via external and internal handles
Cable
Sliding bolt
Special equipment:
Locking mechanism can be operated from the outside
and inside via a profile cylinder (30.5 mm) including
rope, with handle / footboard (integrated in the section)
Sliding bolt (on one side) including rope, incl.
handle on the inside
Locking:
Additional locking of electrically operated doors:
From the inside with electrically operated sliding bolts
(night-time locking)
Weight compensation:
Torsion spring shaft with lateral load-bearing cables
Surface
protection:
Baked enamel finish, double coat on the outside (on acrylate-based 25 m), with removable protective film; single
coat on the inside (polyester-based 10 m). Standard colour similar to RAL 9002 (grey white). Steel parts galvanized. Torsion springs galvanized and shot-blasted.
Glazing frame in aluminium E 6/EV 1 anodized
Glass strips in E 6/EV 1 or unplasticized PVC (black)
Fitting:
N:
ND:
HL:
HLU:
HLD:
Normal fitting
Normal fitting which follows the shape of the roof
High lift runner rail fitting
High lift runner rail fitting with bottom torsion spring shaft
High lift runner rail fitting which follows the shape of the
roof
HLUD:High lift runner rail fitting with roof incline and bottom
torsion spring shaft
NSH: Low headroom fitting with rear spring shaft
NSD: Low headroom fitting which follows the shape of the roof
VL:
Vertical fitting
VLU: Vertical fitting with lower torsion spring shaft
Special equipment:
NS = Low headroom fitting with rear spring shaft
HL = High lift runner rails, VL = Vertically guided runner rails
Types of fittings N, NS and HL also possible as fittings which
follow the shape of the roof.
Required space:
Lateral buffers:
for manual operation on both sides
min. 110 mm
for geared chain on geared chain side
min. 185 mm
for direct mount drive on drive side.
min. 210 mm
for chain drive on drive side.
min. 150 mm
for axial chain
min. 165 mm
NSH /
NSD/NSV
Required
side
space
120
Required
space
geared
chain
185
Required
space
direct mount
drive
210
Required
space
chain
drive
150
Required
space
axial
chain
165
Headroom:
for N fitting
up to door height
Drives:
Glazing:
Wicket
door:
Subject to Technical Changes!
3600 mm min. 400 mm
3610 - 5500 mm min. 450 mm
5510 -7500 mm min. 500 mm
for NS fitting
up to door width
4500 mm min. 250 mm
above door width
4500 mm min. 300 mm
doors with wicket door
min. 320 mm
for HL fitting always specify the headroom
for VL min. headroom = 2 x door height + 500 mm
Manual chain hoist (geared chain)
Electric drive as shaft or chain drive, 3 x 230 V or 400 V. 50 Hz,
power: 0.37 kW/0.42 kW, degree of protection IP 44
Electric drive, rail-guided, 230 V, 50 Hz
Control: Deadman, impulse with self-monitoring test
Other controls possible
2 panes of transparent SAN glazing, with black reduction profile
Window dimensions 620 x 350 mm with rounded corners
Window dimensions 650 x 350 mm rectangular
Special equipment:
Glazed strip, aluminium profiles across the entire door width
(separate section), cold profile (not heat insulated), material
AL-MG-SI 0,5 6/EV 1 anodized. Other colours and powder
coating in acc. with RAL.
2 panes of transparent SAN double glazing, aluminium glazing
strip with seals.
Glazing in double bar plates
Installation of door width 2250 - 6000 mm
With upper slide rails-door closer
Latch and bolt lock with lever/knob, Panic lock, with profile cyl.
Handle on both sides, or knob handle set
Special equipment:
Casing, fixed panels to match the door, side door with upper casing, stop rail; ventilation grille;Special colours in acc. with RAL
203
Sectional Door Double-Skinned Type SW
Teckentrup
optionally with wicket door
Rectangular glazing
Glazing with round corners
SL section
SW door with side door
SW door with wicket door
- Normal fitting (shown)
- Normal fitting with roof incline 30
min. 110
Type
- Low headroom fitting (shown)
- Low headroom fitting with roof incline 20
Depth = ordering dimension
height (BH) +900
Ordering dimension height
Ordering dimension height (BH) *S
Depth = ordering dimension
height (BH) +775
ND
Consider required space
______ for door
Ordering dimension width
Manual Geared
operation chain
SW door with glazing
min. 120
min. 110
Direct
Chain
mo. drive drive
NSH NSD
Drive
Manual operation/
Direct mount drive
Overhead drive
Consider required space
______ for door
min. 120
Ordering dimension width
Type
Manual Geared
Direct
operation chain mount drive
Chain
drive
NSH/NSD Internal drive
120/120 120/120 120/120
120/120 120/120*
NSH/NSD External drive
120/120 120/185 120/210
120/150 120/120*
Overhead
drive
* not possible for NSD overhead drive
- High lift fitting (shown)
- High lift fitting with bottom torsion
HL HLU HLD
spring (shown)
- High lift fitting with roof incline 30
- High lift fitting with roof incline 30
and bottom torsion spring
- Vertical fitting (shown)
- Vertical fitting with bottom torsion spring (shown)
Depth
VL
BH x 2 + S
*S
*S
* Required headroom:
HLU/HLDU
S 1900
Consider required space
______ for door
Ordering dimension width
VLU
Ordering dimension
height (BH)
Ordering dimension height (BH)
min. 110
min. 110
min. 110
BH
BH 5000
BH 5001
BH 5500
BH 5000
*S
BH + 500
Depth
450
BH + 550
BH + 500
510
250
Consider required space
______ for door
Ordering dimension width
min. 110
Required space for system without spring after technical consultation
Type
Direct
Manual Geared
operation chain mount drive
Chain
drive
Type
HL/HLD
110/110 110/185 110/210 110/150
VL
HLU/HLDU
120/120 120/160 120/195 120/135
VLU
Manual Geared
operation chain
Direct
mount drive
Chain
drive
110/110 110/185 110/210 110/150
90/90
90/160
90/195
Dimensions are only valid for the shown versions.The required space is different for a roof incline.
204
VLU
HLDU
Depth = ordering dimension height
(BH) - S + 1550
BH
HL/HLD
BH 6000 S 700
VL
Technical details subject to change!
90/135
Axial
chain
110/165
90/150