Keysight PXA
X-Series Signal Analyzer
N9030A
Coniguration Guide
This PXA coniguration guide will help you
determine which performance options,
measurement applications, accessories,
and services to include with your new PXA
or to add as upgrades to an existing PXA.
02 | Keysight | N9030A PXA X-Series Signal Analyzer - Coniguration Guide
Conigure Your Keysight Technologies PXA Signal Analyzer
This step-by-step process will help you conigure your new PXA X-Series signal analyzer. Tailor the performance to meet your requirements. For detailed speciications, refer to the PXA signal analyzer speciications guide (N9030-90017). For a summary of detailed
speciications, refer to the PXA signal analyzer data sheet (5990-3952EN).
Included in base product
Standard options and accessories come with the PXA base model at no additional charge and do not need to be ordered. They include:
Spectrum analyzer measurement application
Single-core, high-performance processor, 4 GB RAM, removable solid-state drive
Mechanical attenuator
10 MHz analysis bandwidth
Digital processor with 2 GB capture memory
Enhanced phase noise
Fast sweep capability
LO/IM nulling
Low frequency extension
Noise loor extension
Precision frequency reference
Windows Embedded Standard 7
Real-time link
Mouse and keyboard
User guides
Front-panel protective cover
Power cord
3-year return-to-Keysight warranty
Step 1. Select maximum frequency range (required option)
Description
Option number
Frequency range, 3 Hz to 3.6 GHz
N9030A-503
Frequency range, 3 Hz to 8.4 GHz
N9030A-508
Frequency range, 3 Hz to 13.6 GHz
N9030A-513
Frequency range, 3 Hz to 26.5 GHz
N9030A-526
Frequency range, 3 Hz to 43 GHz
N9030A-543
Frequency range, 3 Hz to 44 GHz
N9030A-544
Frequency range, 3 Hz to 50 GHz
N9030A-550
Additional information
03 | Keysight | N9030A PXA X-Series Signal Analyzer - Coniguration Guide
Step 2. Add a preampliier
Description
Option number
Additional information
Preampliier, 100 kHz to 3.0 GHz
N9030A-P03
Compatible with frequency range options: N9030A-503, N9030A-508, N9030A-513,
N9030A-526, N9030A-543, N9030A-544, and N9030A-550
Preampliier, 100 kHz to 8.4 GHz
N9030A-P08
Compatible with frequency range options: N9030A-508, N9030A-513, N9030A-526,
N9030A-543, N9030A-544, and N9030A-550
Preampliier, 100 kHz to 13.6 GHz
N9030A-P13
Compatible with frequency range options: N9030A-513, N9030A-526, N9030A-543,
N9030A-544, and N9030A-550
Preampliier, 100 kHz to 26.5 GHz
N9030A-P26
Compatible with frequency range options: N9030A-526, N9030A-543, N9030A-544,
and N9030A-550
Preampliier, 100 kHz to 43 GHz
N9030A-P43
Compatible with frequency range option: N9030A-543
Preampliier, 100 kHz to 44 GHz
N9030A-P44
Compatible with frequency range option: N9030A-544
Preampliier, 100 kHz to 50 GHz
N9030A-P50
Compatible with frequency range option: N9030A-550
Description
Option number
Additional information
Mechanical attenuator
Standard
2 dB steps, 0 to 70 dB; installed as N9030A-FSA
Electronic attenuator up to 3.6 GHz
N9030A-EA3
Add in addition to the mechanical attenuator; 1 dB steps, 0 to 24 dB
Description
Option number
Additional information
10 MHz analysis bandwidth
Standard
Useful for most 2G and 3G measurement applications
Step 3. Choose an attenuator
Step 4. Choose analysis bandwidth
25 MHz analysis bandwidth
N9030A-B25
Extends the analysis bandwidth from 10 to 25 MHz
40 MHz analysis bandwidth
N9030A-B40
Extends the analysis bandwidth from 10 to 40 MHz
(Option MPB required for measurements > 3.6 GHz)
85 MHz analysis bandwidth
N9030A-B85
Extends the analysis bandwidth from 10 to 85 MHz
(Option MPB required for measurements > 3.6 GHz)
160 MHz analysis bandwidth
N9030A-B1X
Extends analysis bandwidth from 10 to 160 MHz
(Option MPB required for measurements > 3.6 GHz)
Microwave preselector bypass
N9030A-MPB
Bypass the microwave preselector for wider bandwidth IF
04 | Keysight | N9030A PXA X-Series Signal Analyzer - Coniguration Guide
Step 5. Choose performance options
Description
Digital processor with 2 GB
capture memory
Option number
Standard
Additional information
Installed as N9030A-DP2
Enhanced phase noise
Standard
Installed as N9030A-EP1
Fast sweep capability
Standard
Improves sweep speed at swept-tune mode; installed as N9030A-FS1
LO/IM nulling
Standard
Minimizes the LO feed-thru and intermodulation distortion; installed as N9030A-NUL
Noise loor extension
Standard
Improves displayed average noise level (DANL), second-generation algorithm (instrument alignment process); installed as N9030A-NF2
Precision frequency reference
Standard
Aging rate: 1 x 10-7/year; installed as N9030A-PFR
Atomic frequency reference
J7203A
Aging rate: 1 x 10-9/year; ordered as an accesory
Low noise path
N9030A-LNP
Improves sensitivity (DANL) in frequency bands above 3.6 GHz
External mixing
N9030A-EXM
Provides external mixing with Keysight and third party mixers; single port 1 for
LO out and IF in (SMA female)
Fast power
N9030A-FP2
Accelerates the power measurements such as ACPR; requires Option B40
(or B85, B1X)
APC 3.5 mm connector
N9030A-C35
3.5 mm connector on 26.5 GHz PXA (Compatible with Option 526 only)
I/Q baseband inputs, analog
N9030A-BBA
Single-ended/differential, 50 /1 M impedance
(Compatible with Options 503, 508, 513, and 526)
Step 6. Add real-time spectrum analysis
Description
Real-time analysis up to
160 MHz BW, basic detection
Option number
N9030A-RT1
Additional information
Includes Frequency mask trigger; minimum 17.3 s signal duration for 100% probability of intercept (POI); requires N9030A-B85 or N9030A-B1X which determines the
maximum real-time BW
Real-time analysis up to
160 MHz BW, optimum detection
N9030A-RT2
Includes Frequency mask trigger; minimum 3.57 s signal duration for 100% probability of intercept (POI); requires N9030A-B1X or N9030A-B85 which determines the
maximum real-time BW
Real-time spectrum recorder and analyzer
application
N9030A-RTR
Enables recording, analyzing and playback of spectrum density data over time for
detecting and analyzing signal anomalies; requires Option RT1 or RT2
Step 7. Add optional features
Description
Basic EMI precompliance
Option number
N9030A-EMC
Additional information
Perform EMI precompliance measurements with CISPR 16-1-1 detectors and bandwidths: tune and listen, and measure at marker are also available
Enhanced display package
N9030A-EDP
Includes spectrogram, trace zoom, and zone span
External source control
N9030A-ESC
External source control for Keysight EXG, MXG, and PSG signal generators; supports
external mixing; includes 3 BNC cables and 1 crossover LAN cable
Step 8. Choose operating system
Description
Windows Embedded Standard 7
Option number
Standard
Additional information
Installed as N9030A-W7X
Step 9. Add security features
Description
Additional removable
solid-state drive (SSD)
Option number
N9030A-SSD
Additional information
Provides a fully-imaged, removable SSD in addition to the one installed in instruments
Exclude launch program
N9020A-SF1
Prevents the launching of Windows programs from the instrument application
Prohibit saving results
N9020A-SF2
Prevents the saving/recall of measurement results or user conigurations to/from
instruments data storage
1. When used with the Keysight 11970 Series external mixers, an external diplexer is required. Recommended diplexer can be purchased from Keysight as
N9029AE13, or from OML Inc. as DPL313B.
05 | Keysight | N9030A PXA X-Series Signal Analyzer - Coniguration Guide
Step 10. Add rear panel output utilities
Description
Option number
Additional information
Second IF output
N9030A-CR3
Arbitrary IF out
Y-axis video out
Aux log video out
Real-time link
N9030A-CRP
N9030A-YAV
N9030A-ALV
Standard
Wideband IF out; center frequency depends on IF path; output on Aux IF connector at
rear panel
IF out 10 to 75 MHz (in 500 kHz steps); output on Aux IF connector at rear panel
Screen video (0-1 volt open circuit); log video and linear video
Fast rise time video out; output on Aux IF connector
The LVDS connector allows PXA to connect to the X-COM data recorder for data
streaming (up to 40 MHz BW) and N5106A PXB baseband generator and channel
emulator; installed as N9030A-RTL
Step 11. Choose measurement application or software and license type
Note: The last two letters of the ordering numbers indicate the license typeFP stands for ixed perpetual, TP for transportable perpetual; it is recommended that you conigure each application with the same license type; visit www.keysight.com/ind/X-Series_transportable for more information
about transportable licenses
Fixed license
Transportable
license
N9080B-1FP
N9080B-1TP
Standard-based, one-button LTE-FDD measurements; requires W7X - Windows 7
OS. N9080A-1FP/1TP available for Windows XP
N9080B-2FP
N9080B-2TP
Standard-based, one-button LTE-Advanced FDD measurements; requires W7X,
and N9080A or N9080B-1FP/1TP
N9082B-1FP
N9082B-1TP
Standard-based, one-button LTE-TDD measurements; requires W7X - Windows 7
OS. N9082A-1FP/1TP available for Windows XP
N9082B-2FP
N9082B-2TP
Standard-based, one-button LTE-Advanced TDD measurements; requires W7X,
and N9082A or N9082B-1FP/1TP
Multi-standard radio (MSR)
N9083A-1FP
N9083A-1TP
Standard-based, one-button MSR measurements on any
combination of LTE-FDD, W-CDMA/HSPA/HSPA+,
GSM/EDGE/EDGE Evo, cdma2000 and 1xEV-DO signals
W-CDMA/HSPA+
N9073A-1FP
N9073A-1TP
Standard-based, one-button W-CDMA measurements; supports analog baseband
analysis with Option BBA (BBIQ inputs)
N9073A-2FP
N9073A-2TP
Adds HSPA measurements; requires 1FP/1TP
Description
Additional information
Cellular communications
LTE/LTE-Advanced FDD
LTE/LTE-Advanced TDD
N9073A-3FP
N9073A-3TP
Adds HSPA+ measurements; requires 1FP/1TP, 2FP/2TP
GSM/EDGE/EVO
N9071A-2FP
N9071A-2TP
Standard-based, one-button GSM/EDGE measurements;
supports analog baseband analysis with Option BBA (BBIQ inputs)
N9071A-3FP
N9071A-3TP
Adds EDGE Evolution and VAMOS measurements; requires 2FP/2TP
TD-SCDMA/HSPA
N9079A-1FP
N9079A-1TP
Standard-based, one-button TD-SCDMA measurements;
supports analog baseband analysis with Option BBA (BBIQ inputs)
N9079A-2FP
N9079A-2TP
Adds HSPA/8PSK measurements, requires 1FP/1TP
1xEV-DO
N9076A-1FP
N9076A-1TP
Standard-base, one-button 1xEV-DO measurements; supports analog baseband
analysis with Option BBA (BBIQ inputs)
cdma2000/cdmaOne
N9072A-2FP
N9072A-2TP
Standard-based, one-button cdma2000 and cdmaOne; supports analog baseband
analysis with Option BBA (BBIQ inputs)
iDEN/WiDEN/MotoTalk
N6149A-2FP
N6149A-2TP
Standard-based, one-button iDEN measurements
Mobile WiMAX
N9075A-2FP
N9075A-2TP
Standard-based, one-button Mobile WiMAX measurements;
supports analog baseband analysis with Option BBA (BBIQ inputs)
WLAN 802.11a/b/g/n/ac
N9077A-2FP
N9077A-2TP
Standard-based, one-button 802.11a/b/g measurement
N9077A-3FP
N9077A-3TP
Adds 802.11n; requires 2FP/2TP
Wireless connectivity
Bluetooth
N9077A-4FP
N9077A-4TP
Adds 802.11ac; requires 2FP/2TP, 3FP/3TP
N9081A-2FP
N9081A-2TP
Standard-based, one-button Bluetooth version 2.1+ EDR and Low Energy (LE)
measurements
06 | Keysight | N9030A PXA X-Series Signal Analyzer - Coniguration Guide
Step 11. Choose measurement application or software and license type, continued
Fixed license
Transportable
license
CMMB
N6158A-2FP
N6158A-2TP
Standard-based, one-button CMMB measurement; supports analog baseband
analysis with Option BBA (BBIQ inputs)
Digital cable TV
N6152A-2FP
N6152A-2TP
Standard-based, one-button DVB-C (J.83 Annex A/C) measurements; supports
analog baseband analysis with Option BBA (BBIQ inputs)
N6152A-3FP
N6152A-3TP
Standard-based, one-button J.83 Annex B measurements;
supports analog baseband analysis with Option BBA (BBIQ inputs)
DTMB (CTTB)
N6156A-2FP
N6156A-2TP
Standard-based, one-button DTMB (CTTB) measurements;
supports analog baseband analysis with Option BBA (BBIQ inputs)
DVB-T/H/T2
N6153A-2FP
N6153A-2TP
Standard-based, one-button DVB-T/H measurements;
supports analog baseband analysis with Option BBA (BBIQ inputs)
N6153A-3FP
N6153A-3TP
Adds DVB-T2 measurements; requires 2FP/2TP
N6155A-2FP
N6155A-2TP
Standard-based, one-button ISDB-T, ISDB-TB, and ISDB-TSB;
supports analog baseband analysis with Option BBA (BBIQ inputs)
N6155A-3FP
N6155A-3TP
Adds ISDB-Tmm measurements; requires 2FP/2TP
Spectrum analyzer
Standard
Not available
Traditional spectrum analysis plus many new and enhanced functions; power measurements based on industry speciications; installed as N9060B
Analog demodulation
N9063A-2FP
N9063A-2TP
Adds one-button measurement for AM/FM/PM demodulation with metrics, tune
and listen, and AF spectrum; supports audio output (output voltage proportional to
frequency deviation)
N9063A-3FP
N9063A-3TP
Adds FM Stereo and RDS; requires 2FP/2TP
Phase noise
N9068A-2FP
N9068A-2TP
Adds one-button measurements for analyzing phase noise in frequency domain
(log plot) and time domain (spot frequency), supports external mixing
Noise igure
N9069A-1FP
(requires
preampliier)
N9069A-1TP
(requires
preampliier)
Adds one-button measurements for noise igure, gain, and related metrics;
requires preampliier to meet speciications; works with Keysight N400xA Series
smart noise sources and 346 Series noise sources; supports U7227 USB external
preampliiers
N9069A-2FP
N9069A-2TP
Advanced NF measurement features including external LO control over GPIB/LAN/
USB, multi-stage converter tests with system LO, and manual mode to simulate
the legacy NF meter; requires 1FP/1TP
N9064A-1FP
N9064A-1TP
Vector signal analysis; high-resolution, FFT-based spectrum and time-domain
measurements, time gating, AM/FM/PM demodulation, statistical measurements
N9064A-2FP
N9064A-2TP
Adds lexible digital modulation analysis; general purpose digital modulation for
2-16FSK, 2-8PSK, and 16-1024QAM, as well as more than 15 additional formats;
requires 1FP/1TP
N6141A-2FP
N6141A-2TP
Pre-compliance conducted and radiated emission measurements
N6171A-M01
Not available
Basic signal analysis package; adds MATLAB software environment and the Instrument Control Toolbox (not upgradeable)
N6171A-M02
Not available
Standard signal analysis package; includes basic package and adds Communications Toolbox and Signal Processing Toolbox (not upgradeable)
N6171A-M03
Not available
Advanced signal analysis package; includes standard package and adds Filter
Design Toolbox, RF Toolbox, and System Test (not upgradeable)
Description
Additional information
Digital video
ISDB-T/Tmm
General purpose
VXA vector signal analysis
EMC
MATLAB software
07 | Keysight | N9030A PXA X-Series Signal Analyzer - Coniguration Guide
Step 11. Choose measurement application or software and license type, continued
Fixed license
Transportable
license
N9051A-2FP
Not available
Automates pulse measurements; combines signal analysis and amplitude vs. time
measurements
N9051A-3FP
Not available
Adds phase and frequency measurement; requires 2FP
N9051A-4FP
Not available
Adds extended analysis and statistics; requires 2FP
SCPI command language
compatibility
N9062A-2FP
Not available
Adds capability to emulate the R&S FSP/FSU/FSE spectrum analyzers
Remote language
compatibility
N9061A-1FP
Not available
Adds capability to emulate the HP/Agilent 8566/68 spectrum analyzers
N9061A-2FP
Not available
Adds capability to emulate the HP/Agilent 856xE/EC spectrum analyzers
Not available
89601B
(transportable
license is
standard)
Industry-leading measurement software for evaluating and troubleshooting signals
in R&D; PC-based software supporting more than 30 measurement platforms, plus
more than 75 signal standards and modulation types including MIMO analysis;
www.keysight.com/ind/89600_VSA
Description
Option number
Additional information
Mouse, USB interface
Keyboard, USB interface
User guides
Standard
Standard
Standard
Enhances usability of the Windows operating system
Enhances the usability of the Windows operating system
US English localization
All user documentation is included in the embedded context-sensitive help system
inside the PXA and on a DVD that is shipped with the instrument
User documentation can be downloaded from:
www.keysight.com/ind/pxa_manuals
Front-panel protective cover
Power cord
Adapter, 2.4 mm (f) to 2.4 mm (f)
Adapter, 2.4 mm (f) to 2.92 mm (f)
Rack mount
Front handles
Rack mount with handles
Rack slide
USB DVD-ROM/CD-R/RW drive
US 65-key USB keyboard
Minimum loss pad, 50 to 75
(type-N to BNC)
Standard
Standard
Standard
Standard
N9030A-1CM
N9030A-1CN
N9030A-1CP
N9030A-1CR
N9030A-DVR
N9030A-KB2
N9030A-MLP
V-band waveguide harmonic mixer, 50 to 75 GHz
Extended V-band waveguide harmonic mixer, 50
to 80 GHz
E-band waveguide harmonic mixer, 60 to 90 GHz
W-band waveguide harmonic mixer, 75 to 110
GHz
26 to 40 GHz waveguide harmonic mixer
33 to 50 GHz waveguide harmonic mixer
40 to 60 GHz waveguide harmonic mixer
50 to 75 GHz waveguide harmonic mixer
75 to 110 GHz waveguide harmonic mixer
LO/IF diplexer
90 to 140 GHz OML harmonic mixer
110 to 170 GHz OML harmonic mixer
M1970V-001
M1970V-002
Depends on the region of use
Only for PXA with Option 543, 544, or 550
Only for PXA with Option 543, 544, or 550
Adds rack mount langes to the PXA
Adds front handles to the PXA
Adds rack mount langes and handles to the PXA
Adds a non-tilting rack slide to the PXA
Enhances the usability of the Windows operating system
Smaller keyboard
50 type-N male to 75 BNC female adapter
Frequency range: 9 MHz to 2 GHz
Input/output return loss: 20 and 11 dB
Insertion loss: 5.7 dB
Requires Option EXM; USB mixer with smart features
Requires Option EXM; USB mixer with smart features
M1970E
M1970W
Requires Option EXM; USB mixer with smart features
Requires Option EXM; USB mixer with smart features
11970A
11970Q
11970U
11970V
11970W
N9029AE13
N9029AE08
N9029AE06
Requires Option EXM and N9029AE13 diplexer
Requires Option EXM and N9029AE13 diplexer
Requires Option EXM and N9029AE13 diplexer
Requires Option EXM and N9029AE13 diplexer
Requires Option EXM and N9029AE13 diplexer
Ordering convenience; required for 11970 Series external mixers
Ordering convenience; requires Option EXM
Ordering convenience; requires Option EXM
Description
Additional information
General purpose, continued
Pulse
89600 vector signal analysis
(VSA) software
Step 12. Choose accessories
08 | Keysight | N9030A PXA X-Series Signal Analyzer - Coniguration Guide
Step 12. Choose accessories
Description
Option number
Additional information
140 to 220 GHz OML harmonic mixer
220 to 325 GHz OML harmonic mixer
50 to 75 GHz frequency extension module
60 to 90 GHz frequency extension module
75 to 110 GHz frequency extension module
90 to 140 GHz frequency extension module
110 to 170 GHz frequency extension module
140 to 220 GHz frequency extension module
220 to 330 GHz frequency extension module
325 to 500 GHz frequency extension module
550 to 750 GHz frequency extension module
750 to 1100 GHz frequency extension module
Power supply for VDI module
Atomic frequency reference
N9029AE05
N9029AE03
N9029AV15
N9029AV12
N9029AV10
N9029AV08
N9029AV06
N9029AV05
N9029AV03
N9029AV02
N9029AV1B
N9029AV01
N5262VDI-175
J7203A
USB external preampliier, 10 MHz to 4 GHz
USB external preampliier, 0.1 to 26.5 GHz
USB external preampliier, 2 to 50 GHz
U7227A
U7227C
U7227F
Ordering convenience; requires Option EXM
Ordering convenience; requires Option EXM
VDI signal analyzer frequency extension module; requires Option EXM
VDI signal analyzer frequency extension module; requires Option EXM
VDI signal analyzer frequency extension module; requires Option EXM
VDI signal analyzer frequency extension module; requires Option EXM
VDI signal analyzer frequency extension module; requires Option EXM
VDI signal analyzer frequency extension module; requires Option EXM
VDI signal analyzer frequency extension module; requires Option EXM
VDI signal analyzer frequency extension module; requires Option EXM
VDI signal analyzer frequency extension module; requires Option EXM
VDI signal analyzer frequency extension module; requires Option EXM
Required for the N9029AVxx VDI module
Improves long-term frequency stability; requires irmware A.14.00 or
higher
Requires irmware A.14.00 or higher
Requires irmware A.14.00 or higher
Requires irmware A.14.00 or higher
Step 13. Choose localized Getting Started guides
Description
Option number
Getting started guide PXA Korean localization
Getting started guide PXA Chinese localization
Getting started guide PXA German localization
Getting started guide PXA French localization
Getting started guide PXA Japanese localization
Getting started guide PXA Russian localization
N9030A-AB1
N9030A-AB2
N9030A-ABD
N9030A-ABF
N9030A-ABJ
N9030A-AKT
For more information on accessories go to: www.keysight.com/ind/accessories
Step 14. Choose warranty length
Description
Option number
Additional information
Return-to-Keysight warranty, 3 years
Warranty Assurance Plan,
Return-to-Keysight, 5 years
Standard
R-51B-001-5C
3-year warranty is included at no additional charge
Step 15. Add calibration, technical training, support, and upgrade services
Description
Option number
Additional information
Commercial calibration certiicate with test data
N9030A-UK6
Keysight Calibration + Uncertainties +
Guardbanding (accredited cal)
ANSI Z540-1-1994 Calibration
Calibration Assurance Plan,
Return-to-Keysight, 3 years
N9030A-AMG
Calibration certiicate only available at time of instrument
purchase; only provides measurement results
Provides ISO 17025A accredited calibration from factory
N9030A-A6J
R-50C-011-3
Provides ANSI Z540 compliant calibration from factory
Keysight tests your instrument against its original speciications and
automatically makes adjustments if outside of speciied parameters;
pre- and post-adjustment measurement data reports also provided
For more information on accessories go to: www.keysight.com/ind/accessories
Other calibration options may be available; for more information on calibration go to: www.keysight.com/ind/calibration
For more information on training and application support services go to: www.keysight.com/ind/training
09 | Keysight | N9030A PXA X-Series Signal Analyzer - Coniguration Guide
Instrument Upgrades
Fast license-key upgrades for performance options that do not require
additional hardware:
1. Place an order for the upgrade with Keysight and request to receive the
option upgrade entitlement certiicate and a one-time software upgrade
license through email
2. Redeem the certiicate through the Web by following the instructions on
the certiicate
3. Install the license ile and latest software in the PXA
4. Begin using the new capability 1, 2 Installation and testing information is
available at: www.keysight.com/ind/pxa_upgrades
Upgrades for analysis bandwidth depend on the vintage of the instrument and
the options already installed. More than one option may be required to achieve
desired wider analysis bandwidth. Use our web-based calculator to ind the
upgrade options you may need: www.keysight.com/ind/BW-selector
You Can Upgrade!
Options can be
added after your
initial purchase.
UP
GRADE
Most X-Series options are
license-key upgradeable.
Description
Upgrade number
Increase frequency from 3.6 to 8.4 GHz
N9030AK-F01
Requirements (PXA must
already include the following)
503
Increase frequency from 3.6 to 13.6 GHz
N9030AK-F02
503
Increase frequency from 3.6 to 26.5 GHz
N9030AK-F03
503
Increase frequency from 3.6 to 44 GHz
N9030AK-F04
503
Not compatible with Option BBA
Increase frequency from 3.6 to 50 GHz
N9030AK-F05
503
Not compatible with Option BBA
Increase frequency from 8.4 to 13.6 GHz
N9030AK-F06
508
Increase frequency from 8.4 to 26.5 GHz
N9030AK-F07
508
Increase frequency from 8.4 to 44 GHz
N9030AK-F08
508
Not compatible with Option BBA
Increase frequency from 8.4 to 50 GHz
N9030AK-F09
508
Not compatible with Option BBA
Increase frequency from 13.6 to 26.5 GHz
N9030AK-F10
513
Increase frequency from 13.6 to 44 GHz
N9030AK-F11
513
Not compatible with Option BBA
Increase frequency from 13.6 to 50 GHz
N9030AK-F12
513
Not compatible with Option BBA
Increase frequency from 26.5 to 44 GHz
N9030AK-F13
526
Not compatible with Option BBA
Increase frequency from 26.5 to 50 GHz
N9030AK-F14
526
Not compatible with Option BBA
Increase frequency from 43/44 to 50 GHz
N9030AK-F15
543/544
Includes 50 GHz preamp
1.
Additional information
At the time of manufacture, the hardware related to many of these options was fully adjusted and the option performance was veriied to be within its warranted speciications. Within one year of the initial calibration date of the analyzer, this option is fully calibrated with no further adjustment or veriication
testing.
2. If this analyzer has been adjusted as part of a repair or calibration during its irst year, or if the analyzer is more than one year old, additional adjustment and
performance veriication tests are required to ensure that some newly installed options are functioning properly. However, the completion of these tests
does not guarantee that the analyzer meets all warranted speciications.
010 | Keysight | N9030A PXA X-Series Signal Analyzer - Coniguration Guide
Description
Upgrade number
Increase analysis bandwidth
from 10 to 25 MHz
Increase analysis bandwidth
from 10 to 40 MHz
Increase analysis bandwidth
from 25 to 40 MHz
Increase analysis bandwidth
from 40 to 85 MHz
Increase analysis bandwidth
from 40 to 160 MHz
Increase analysis bandwidth
from 10/25 to 85 MHz
Increase analysis bandwidth
from 10/25 to 160 MHz
Increase analysis bandwidth
from 85 to 160 MHz
Increase analysis bandwidth
from 140 to 160 MHz
Real-time analysis up to
160 MHz BW, basic detection
N9030AK-B25
Real-time analysis up to
160 MHz BW, optimum detection
N9030AK-B40
N9030AK-BU1
N9030AK-HLB
N9030AK-BU2
N9030AK-B85
N9030AK-B1X
N9030AK-BU5
N9030AK-BU3
N9030AK-RT1
N9030AK-RT2
Real-time spectrum recorder and N9030AK-RTR
analyzer application
Requirements (PXA must
already include the following)
None
MPB
(for measurements > 3.6 GHz)
MPB
(for measurements > 3.6 GHz)
MPB
(for measurements > 3.6 GHz)
MPB
(for measurements > 3.6 GHz)
MPB
(for measurements > 3.6 GHz)
MPB
(for measurements > 3.6 GHz)
MPB
(for measurements > 3.6 GHz)
MPB
(for measurements > 3.6 GHz)
B85 or B1X
(Analysis BW option determines
maximum real-time BW)
B1X or B85
(Analysis BW option determines
maximum real-time BW)
RT1 or RT2
Add an electronic attenuator, 3.6
GHz
Add preampliier, 3.6 GHz
N9030AK-EA3
None
N9030AK-P03
Add preampliier, 8.4 GHz
Add preampliier, 13.6 GHz
Add preampliier, 26.5 GHz
N9030AK-P08
N9030AK-P13
N9030AK-P26
550, 544, 543, 526, 513, 508,
or 503
550, 544, 543, 526, 513, or 508
550, 544, 543, 526, or 513
550, 544, 543, or 526
Additional information
Also enables 25 MHz per channel baseband bandwidth if
Option BBA is installed
Also enables 40 MHz per channel baseband bandwidth if
Option BBA is installed
Also enables 40 MHz per channel baseband bandwidth if
Option BBA is installed
Includes additional hardware
Includes additional hardware
Includes additional hardware
Includes additional hardware
Includes frequency mask trigger; minimum 17.3 s signal
duration for 100% POI. Combination of Win7/PC4 or WinXP/
PC2 required for optimal display performance.
Includes frequency mask trigger; minimum 3.57 s signal
duration for 100% POI. Combination of Win7/PC4 or WinXP/
PC2 required for optimal display performance.
Enables recording, analyzing and playback of spectrum
density data for detecting and analyzing signal anomalies
over time
1. At the time of manufacture, the hardware related to many of these options was fully adjusted and the option performance was
veriied to be within its warranted speciications. Within one year of the initial calibration date of the analyzer, this option is fully
calibrated with no further adjustment or veriication testing.
2. If this analyzer has been adjusted as part of a repair or calibration during its irst year, or if the analyzer is more than one year old,
additional adjustment and performance veriication tests are required to ensure that some newly installed options are functioning
properly. However, the completion of these tests does not guarantee that the analyzer meets all warranted speciications.
011 | Keysight | N9030A PXA X-Series Signal Analyzer - Coniguration Guide
Description
Upgrade number
Requirements (PXA must
already include the following)
Add preampliier, 43 GHz
N9030AK-P43
543
Add preampliier, 44 GHz
N9030AK-P44
544
Add preampliier, 50 GHz
N9030AK-P50
550
Add APC 3.5 mm connector
N9030AK-C35
526
Includes additional hardware
Add I/Q baseband inputs, analog
N9030AK-BBA
526, 513, 508, or 503
Includes additional hardware
Additional information
Upgrade operating system to Windows Embedded Standard 7
From 32-bit processor
N9094AK-W7X
N9094AK-PC4
(Under the N9030AK)
PC2
Upgrade the existing 32-bit processor with
Windows XP to a 64-bit performance processor, 8 GB
RAM, with removable solid-state drive and Windows 7.
From 64-bit processor
N9094AK-W7X
N9094AK-SSD
(Under the N9030AK)
PC4
For existing 64-bit processors provides operating
system and removable solid-state drive
Upgrade to dual core 64-bit performance processor, 8 GB RAM, removable solid-state drive
N9094AK-W7X
N9094AK-PC4
(Under the N9030AK)
PC2
With Windows 7 operating
system
N9094AK-W7X
N9094AK-SSD
(Under the N9030AK)
PC4
For Windows 7 operating system provides additional
removable solid-state drive
With Windows XP operating
system
N9094AK-WXP
N9094AK-SSD
(Under the N9030AK)
None
For Windows XP operating system provides additional
removable solid-state drive; last order date is March
1, 2015
Add external mixing
N9030AK-EXM
550, 544, or 543; 526, 513,
508, or 503 with serial preix
MY/SG/US5138
Includes additional hardware
Add external mixing
N9030AK-HL6
526, 513, 508, or 503 with
serial preix < MY/SG/US5138
Includes additional hardware
Add second IF output
N9030AK-CR3
None
Provides wideband IF out, output center frequency
depends on IF path
Add microwave preselector bypass
N9030AK-MPB
LNP or B1X
Add low noise path
N9030AK-LNP
MPB or B1X
Hardware and license preselector
bypass and low noise path
N9030AK-HL1
N9030AK-HL2
526, 513, 508
550, 544, 543
Add Y-axis video output
N9030AK-YAV
None
Arbitrary IF output
N9030AK-CRP
None
Add auxiliary log video out
N9030AK-ALV
None
Add fast power
N9030AK-FP2
B40, B85, or B1X
With Windows 7 operating
system
Add removable solid-state drive
Includes additional hardware; installs both Options
MPB and LNP when neither are previously installed
Provides user-programmable IF out
(10 to 75 MHz, at 500 kHz step)
Accelerates power measurements such as ACPR
12 | Keysight | N9030A PXA X-Series Signal Analyzer - Coniguration Guide
Description
Upgrade number
Requirements (PXA must
already include the following)
Add precompliance EMI features
N9030AK-EMC
None
Add enhanced display package
N9030AK-EDP
None
Add external source control
N9030AK-ESC
None
Adds feature to control the Keysight EXG, MXG, and
PSG signal generators for scalar stimulus/response
measurements. Ships with 3 BNC cables and 1 crossover LAN cable.
Add security features, exclude launch N9030AK-SF1
program
None
Prevents the launching of Windows programs from the
instrument application
Add security features, prohibit saving N9030AK-SF2
results
None
Prevents the saving /recall of measurement results or
user conigurations to/from instruments data storage
USB DVD-ROM/CD-R/RW drive
N9030AK-DVR
None
Includes additional hardware
Keyboard, USB interface
N9030AK-KYB
None
Full-sized USB keyboard; includes additional hardware
65-key USB keyboard
N9030AK-KB2
None
Smaller keyboard than Option KYB; includes additional hardware
Rack mount and handle kit
N9030AK-1CP
None
Includes additional hardware
Rack slide kit
N9030AK-1CR
None
Includes additional hardware
Front handle kit
N9030AK-1CN
None
Includes additional hardware
Rack mount kit
N9030AK-1CM
None
Rack mount langes; not compatible with Options 1CP,
1CN; includes additional hardware
Minimum loss pad, 50 to 75
(type-N to BNC)
N9030AK-MLP
None
50 type-N male to 75 BNC female adapter;
frequency range: 9 MHz to 2 GHz; input/output return
loss: 20 and 11 dB; insertion loss: 5.7 dB; includes
additional hardware
Front panel protective cover, additional
N9030AK-CVR
None
Includes additional hardware
Getting started guide PXA Korean
localization
N9030AK-AB1
None
Getting started guide PXA Chinese
localization
N9030AK-AB2
None
Getting started guide PXA German
localization
N9030AK-ABD
None
Getting started guide PXA French
localization
N9030AK-ABF
None
Getting started guide PXA Japanese
localization
N9030AK-ABJ
None
Getting started guide PXA Russian
localization
N9030AK-AKT
None
Additional information
Compliant with CISPR 16-1-1 2007 detectors and
BWs
13 | Keysight | N9030A PXA X-Series Signal Analyzer - Coniguration Guide
Related Literature
Keysight PXA signal analyzers
Publication title
Publication number
Brochure
5990-3951EN
Data Sheet
5990-3952EN
X-Series Measurement Applications Brochure
5990-8019EN
myKeysight
www.keysight.com/find/mykeysight
A personalized view into the information most relevant to you.
www.lxistandard.org
LAN eXtensions for Instruments puts the power of Ethernet and the
Web inside your test systems. Keysight is a founding member of the LXI
consortium.
Three-Year Warranty
www.keysight.com/find/ThreeYearWarranty
Keysights commitment to superior product quality and lower total cost
of ownership. The only test and measurement company with three-year
warranty standard on all instruments, worldwide.
www.keysight.com/quality
Keysight Technologies, Inc.
DEKRA Certified ISO 9001:2008
Quality Management System
Keysight Channel Partners
www.keysight.com/find/channelpartners
Get the best of both worlds: Keysights measurement expertise and product
breadth, combined with channel partner convenience.
For more information on Keysight
Technologies products, applications or
services, please contact your local Keysight
office. The complete list is available at:
www.keysight.com/find/contactus
Americas
Canada
Brazil
Mexico
United States
(877) 894 4414
55 11 3351 7010
001 800 254 2440
(800) 829 4444
Asia Paciic
Australia
China
Hong Kong
India
Japan
Korea
Malaysia
Singapore
Taiwan
Other AP Countries
1 800 629 485
800 810 0189
800 938 693
1 800 112 929
0120 (421) 345
080 769 0800
1 800 888 848
1 800 375 8100
0800 047 866
(65) 6375 8100
Europe & Middle East
Austria
Belgium
Finland
France
Germany
Ireland
Israel
Italy
Luxembourg
Netherlands
Russia
Spain
Sweden
Switzerland
WiMAX is a trademark of the WiMAX Forum
Bluetooth and the Bluetooth logos are trademarks owned by Bluetooth SIG, Inc., U.S.A. and
licensed to Keysight Technologies, Inc.
cdma2000 is a U.S. registered certiication mark of the Telecommunications Industry Association.
www.keysight.com/find/pxa
United Kingdom
0800 001122
0800 58580
0800 523252
0805 980333
0800 6270999
1800 832700
1 809 343051
800 599100
+32 800 58580
0800 0233200
8800 5009286
0800 000154
0200 882255
0800 805353
Opt. 1 (DE)
Opt. 2 (FR)
Opt. 3 (IT)
0800 0260637
For other unlisted countries:
www.keysight.com/find/contactus
(BP-07-10-14)
This information is subject to change without notice.
Keysight Technologies, 2013 - 2014
Published in USA, November 3, 2014
5990-3953EN
www.keysight.com