RX daytona
A compact benchtop solution
for clinical chemistry testing
RX daytona
Flexible, versatile and efficient
The RX daytona can provide a performance
like no other with an industry leading test
menu on a cost effective, compact analyser.
Have confidence in testing with accurate and reliable results from
the RX daytona. The compact fully automated clinical chemistry
analyser can provide rapid, cost effective testing for informed
and dependable decisions, from the bench top to the bedside.
RX daytona system overview
Unique dual three speed stirring system
Versatile reagent carousel
with 40 cooled positions
RX daytona gives unrivalled performance
guaranteed with:
The largest clinical chemistry test menu on the market
providing complete consolidation of specialised and routine
tests onto one platform.
International accreditation ensures high quality testing you can trust.
Dedicated RX support team provides instant expert
knowledge and advice when you need it most.
Versatile applications for a variety of settings including:
Clinical Chemistry laboratories
Research laboratories
Food and wine testing
Veterinary laboratories
Forensic toxicology
45 Permanent Pyrex cuvettes
Universal sample carousel
with 40 positions
Optional Integrated
ISE unit
Why RX daytona?
A compact high performance system for all tests
Advanced onboard stability
Cooled reagent carousel extends
stability and reduces reagent wastage
40 cooled positions enable reagent
overnight storage onboard the analyser
Most comprehensive
test menu on the market
Wider range of tests available than any
other sole supplier
Ability to run specific protein tests removes
the need for a separate nephelometry system
Highly accurate testing
Separate reagent and sample probes
minimise contamination and carry over
Unique three speed rotating stirrers optimise
mixing for each assay
Serum indices detect haemolysed, icteric
or lipaemic samples building confidence
in results and reducing expensive repeats
Dedicated onboard micropipettes with
liquid level sensor and crash protection
STAT sampling
Immediate sampling interruption for
STAT addition
Time saving
Pre-programmed settings eliminate the need
to input test parameters
True walk away automation optimises staff time
Auto sample re-run function reduces
downtime and eliminates risk of human error
Minimal daily maintenance and lowest service
requirements in its class
Built in inventory
management system
The RX daytona automatically calculates
remaining reagent volume and the number
of tests available
Storage capacity of 100,000 test results
including 10,000 patient results and data
for up to 30 controls
Flexibility
Capable of running monochromatic,
bi-chromatic, endpoint, kinetic, ISE, sample
blanking and reagent blanking assays
Filters provide coverage at wavelengths
340, 415, 510, 546, 570, 600, 660 and 700nm
Six different calibration options available
including linear, factor, 2 point, point to point,
log-logit and exponential
Cost savings
No extra consumables required
Five year permanent reusable pyrex cuvettes
Universal sample carousel-holds all standard
sample vessels
Economic platform with low water
consumption at 7.5L per hour
Minimal reagent volumes required per test
Optimum laboratory
efficiency
System calculates remaining reagent volume
and number of tests available
Complete package of IQC and EQA available
Bar coded reagents and samples mean no
time is wasted programming routine assays
Programmable analyser autostart function
Unrivalled QC capabilities
Automatic generation of Levey Jennings
charts, running mean values and QC statistics
User defined multipoint rules to identify any
trends or bias
High throughput
180 photometric tests per hour
270 ISE tests per hour
RX daytona software
Ensures straightforward and intuitive operations
Run monitor screen
Connectivity
Software capable of connecting
to LIMS system via ASTM standard
RX series software
commonality
Simplistic and
intuitive operations
Software consistent across all of
the RX series, for ease-of-use and
straightforward operations
Microsoft Windows based
software offers ease of navigation.
Intuitive software results in
minimal training requirements
and enhanced productivity
Control operations from the main screen
with six informative software tabs
Run monitor screen
Displays full patient demographics
View status in real time including time
to completion
System parameters screen
Define up to 15 normal ranges
Quality control screen
Levey-Jennings charts, running mean
values and QC
Quality control screen
Chemistry parameter screen
Set up to eight test profiles and define
order of analysis
Enables sample dilution and test re-runs
Maintenance screen
Less than five minutes daily
maintenance required
Results screen
Download and print results
Calibration screen
Sets calibrator serial dilution and displays
multipoint calibration curves
Calibration screen
Easy to follow reports
View real time results status,
including time to completion
Reduces downtime
Save time and costs with secure
remote diagnostics allowing
immediate support from expert
technical and applications staff,
anytime, anywhere!
RX daytona test menu
Largest clinical chemistry test menu on the market
Clinical
Autoimmune:
Complement Component 3
Complement Component 4
CRP
CRP Full Range (0.3-160mg/l)
CRP High Sensitivity
IgA
IgE
IgG
IgM
Rheumatoid Factor
Basic Metabolic Profile:
Calcium
CO2 Total
Chloride
Creatinine Enzymatic
Creatinine (Jaffe)
Glucose
Potassium
Sodium
Urea
Bone Profile:
Alkaline Phosphatase
Calcium
Phosphorus
Total Protein
Cardiac:
Cholesterol
CK-MB
CK-NAC
CRP
CRP Full Range (0.3-160mg/l)
CRP High Sensitivity
Digoxin
Direct HDL Cholesterol
Direct LDL Cholesterol
Heart-Type Fatty Acid Binding Protein
(H-FABP)
Lipoprotein (a)
Myoglobin
sLDL
Triglycerides
TxB Cardio
Comprehensive Metabolic Profile:
Albumin
Alkaline Phosphatase
ALT
AST (GOT)
Direct Bilirubin
Calcium
Chloride
CO2 Total
Creatinine Enzymatic
Creatinine (Jaffe)
Glucose
Lactate
Potassium
Sodium
Total Bilirubin
Total Protein
Urea
Diabetes:
Cholesterol
Creatinine Enzymatic
Creatinine (Jaffe)
Cystatin C
Direct HDL Cholesterol
Direct LDL Cholesterol
Fructosamine
Glucose
Glycerol
HbA1c/Hb
Microalbumin
NEFA (Non-Esterified Fatty Acids)
Ranbut (Hydroxybutyrate)
Total Protein
Triglycerides
Urinary Protein
Electrolytes
Calcium
Chloride (Direct / Nondirect)
CO2 Total
Lithium
Magnesium
Potassium (Direct / Nondirect)
Sodium (Direct / Nondirect)
Haemolytic Anaema:
G6P-DH
Haptoglobin
LDH
Hepatic Function:
Albumin
Aldolase
Alkaline Phosphatase
Alpha-1 Antitrypsin
ALT
Ammonia
AST (GOT)
Cholinesterase
Complement Component 3
Complement Component 4
Direct Bilirubin
Gamma GT
GLDH
Glycerol
Haptoglobin
IgA
IgG
IgM
Iron (UIBC)
LAP
LDH
Total Bilirubin
Total Protein
Transferrin
Transthyretin (Prealbumin)
Neonatal Screening:
Alpha-1 Antitrypsin
CRP
CRP Full Range (0.3-160mg/l)
CRP High Sensitivity
IgE
Transthyretin (Prealbumin)
Inflammation and Infection:
Alpha-1Acid Glycoprotein
ASO
CRP
Lactate
Rheumatoid Factor
Pancreatic Function:
Amylase
Glucose
LDH
Lipase
Pancreatic Amylase
Lipids:
Apolipoprotein A-1
Apolipoprotein AII
Apolipoprotein B
Apolipoprotein CII
Apolipoprotein CIII
Apolipoprotein E
Cholesterol
Direct HDL Cholesterol
Direct LDL Cholesterol
Lipoprotein (a)
sLDL
Triglycerides
Renal Function:
Albumin
Ammonia
Beta-2 Microglobulin
Calcium
Chloride
Creatinine Enzymatic
Creatinine (Jaffe)
Cystatin C
Glucose
HbA1c/Hb
IgG
LDH
Magnesium
Microalbumin
Potassium
Sodium
Phosphorus (Inorganic)
Urinary Protein
Urea
Uric Acid
Neurological Disorders (CSF):
IgA
IgG
IgM
Nutritional Status:
Albumin
Copper
Ferritin
Iron
Iron (UIBC)
Lipase
Magnesium
Potassium
TIBC
Transferrin
Transthyretin (Prealbumin)
Zinc
Veterinary
Albumin
Alkaline phosphatase
ALT (GPT)
Aldolase
Ammonia
Amylase
AST (GOT)
Bile acids
Bilirubin
Calcium
Chloride
Cholesterol
Cholinesterase (Butyryl)
CK-NAC
CO2 Total
Copper
Creatinine
CRP
Fructosamine
Gamma-GT
GLDH
Glucose
Glycerol
HDL
Iron (UIBC)
Lactate
Lactate dehydrogenase
LDL
Lipase
Magnesium
NEFA (Non-esterified fatty acids)
Phosphorus (Inorganic)
Potassium
Ranbut (Hydroxybutyrate)
Ransel (Glutathione peroxidase)
Ransod (Superoxide dismutase)
Sodium
Therapeutic drugs
Total Protein
Triglycerides
Urea
Uric Acid
Urinary protein
Zinc
Phenobarbitol
Phenytoin
Salicylate
Theophyline
Valproic Acid
Drugs of Abuse:
Amphetamines
Barbiturates
Benzodiazepines
Cannabinoids
Cocaine metabolite
EDDP
Ecstasy
Ethanol
Methadone
Opiates
Apolipoprotein E
ASO
Beta-2 Microglobulin
Ceruloplasmin
Complement Component 3
Complement Component 4
CRP
CRP Full Range (0.3-160mg/l)
CRP High Sensitivity
Cystatin C
Ferritin
Fructosamine
Haptoglobin
HbA1c/Hb
IgA
IgE
IgG
IgM
Lipoprotein (a)
Microalbumin
Myoglobin
Rheumatoid Factor
Transthyretin (Prealbumin)
Transferrin
Biotechnology:
Glutamate
Glutamine
Food and Wine Testing:
Acetic Acid
Ammonia
Calcium
Copper
Glucose
Glucose/Fructose
Glycerol
Iron
L-Lactic Acid
Malic Acid
Potassium
Total Antioxidant Status
Speciality:
Acid phosphatase
Toxicology
Therapeutic Drugs:
Carbamazepine
Digoxin
Gentamicin
Lithium
Acetaminophen
Protein
Specific Proteins:
Alpha-1 Antitrypsin
Alpha-1 Acid Glycoprotein
Apolipoprotein A-1
Apolipoprotein AII
Apolipoprotein B
Apolipoprotein CII
Apolipoprotein CIII
Research
Antioxidants:
Albumin
Bilirubin
Ferritin
Glutathione Reductase
Ransel (Glutathione Peroxidase)
Ransod (Superoxide Dismutase)
TIBC
Total Antioxidant Status
Transferrin
Uric Acid
Unrivalled customer service
Our global network, ensuring local support
At Randox our highly specialised RX
support team is on hand with expert
advice and support regardless of where
you are in the world. Our global team
of expert technical and applications staff
ensure unbeatable service for hassle free
diagnostics.
Time is critical in any laboratory, therefore
you are our top priority. Dedicated
specialists answer all queries in a quick
and thorough manner and our field
agents are on hand at any time so you
can be sure of a quick response.
Remote Access diagnostics
Our ground breaking Remote Access
diagnostics allows immediate support to
your system reducing down time and the
expense associated with timely call outs.
Randox is committed to the smooth
running of your laboratory ensuring that
your system will remain operational with
optimum productivity. Our unrivalled
customer support and quality products
also extends in the form of our leading
IQC and EQA programmes, 24.7, a peer
group IQC programme and RIQAS the
largest global EQA scheme in the world.
email: rxsupport@randox.com
RX family of analysers
The RX daytona
provides the solution for
consolidated, high quality
clinical chemistry testing
Clinical chemistry testing has advanced dramatically in recent
years with demands fixed on consolidation, speed, quality
and cost. Randox is committed to advancing diagnostic
testing to suit our customers. Investing heavily into research
and development, Randox has developed a full range of
clinical chemistry analysers to suit any working environment
RX monza
RX daytona
Versatility for reduced cost, low-volume
manual testing. The RX monza semi-automated
clinical analyser has an integral screen,
keyboard and printer.
Convenient bench top system, the RX daytona
clinical analyser has a throughput of 450 tests
per hour including ISEs via the optional ISE unit.
including clinical, paediatric, research, veterinary, forensic
and pharmaceutical laboratories.
The RX series of clinical analysers has an impressive range
of time-saving and cost-saving features. All of which offer
outstanding flexibility coupled with optimum reliability.
RX imola
RX suzuka
Designed for medium to high throughout
laboratories, the RX imola is a random access
bench top clinical analyser with a maximum
throughput of 560 tests per hour including ISEs.
The latest addition to the RX family of analysers;
the RX suzuka is a fully automated, discrete,
random access clinical analyser with a throughput
of 1200 tests per hour including ISEs.
Specif ications
Physical Dimensions
Height
Depth
Width
Weight
550 mm, 24.5 in
620 mm, 20 in
770 mm, 30 in
135 kg, 298 lbs
Performance Characteristics
Analyser Accreditation
Analyser Type
Assay Tests
Calibration Principal
Cuvettes
Cycle Time
Data Management
Detection Principal
Detector Method
ISE Unit
Light Source
LIMS Connectivity
Maintenance
Maximum Humidity
Minimum Reaction Volume
Operator Interface
Quality Control
Reagent Capacity
Reagent Cooling
Reagent Identification
Reagent Inventory
Reagent Pipette
Reagent Volume
Sample Addition
Sample Capacity
Sample Dead Volume
Sample Dilution
Sample Identification
Sample Pipette
Sample Type
CE marking in compliance with In Vitro Diagnostic Medical Device Directive 98/79/EC,
FDA 510k cleared and UL certification
Compact fully automated random access bench top clinical analyser
Endpoint, kinetic, biochromatic, turbidmetric, sample blanking, reagent blanking and ISE (via
optional integrated ISE unit)
Factor, Linear, 2 point, point to point, spline, log-logit and exponential, Up to 7 calibrators
per test
45 resusable Pyrex cuvettes with 5-year lifespan, min volume 180l, Max volume 500l,
8-stage cuvette washing system
20 seconds
Storage of up to 10,000 patient reports, search facility
8 wavelengths: 340, 415, 510, 546, 570, 600, 660, 700 nm
Direct absorbance in cuvette (bichromatic and monochromatic)
Optional ISE unit available
Halogen tungsten lamp (Air-cooled, 6 months service life)
Bi-directional; ASTM Standard (RS232 connection)
Daily maintenance- less than 5 minutes. No rear access required. Simple twice yearly
preventative maintenance.
45-85% without condensation
180l
15 LCD display and printer externally connected. Windows XP based user interface
Interactive Levey Jennings Charts, Daily, monthly and batch QC with data archiving,
Automatic QC and Automatic calibration
Removable tray with 40 cooled positions (20 positions for 100, 50 or 20ml bottles and 20
positions for 20ml bottles)
8-15C
Automatic barcode reagent identification
Calculation of remaining reagent volume and tests available. Alert for shortage, expired
reagent and expired calibration
Dedicated reagent micropipette with liquid level sensor and crash detection. Rinsed inside
and outside with purified water
20-400l ( in 1l increments)
Sampling interruption for addition of samples
Removable tray with 40 positions for samples, calibrators and controls
100l in standard or primary tubes, 50l in paediatric cups
Pre-dilution and automatic re-assay with diluted, reduced or increased sample volume
Barcode sample identification
Dedicated sample micropipette with liquid level sensor and crash protection, rinsed inside
and outside with purified water
Serum, plasma, CSF, urine and supernatants
Sample Tube Size
Sample Volume
STAT Sampling
Stirring Speed
Stirring System
Temperature
Test Channels
Throughput
Time to First Result from
Sample Barcode Scan
Time to First Result from Standby
Water Consumption
Water Requirements
Walk-away Time
Multiple primary tube sizes (diameter 12 to 16mm, height 55 to 100 mm), paediatric cups
2 to 35l (0.1l increments)
Immediate STAT sampling interruption
Dual 3-speed rotating stirrers
Stick type rotating stirrer cleaned with purified water
37C0.3
40 photometric channels, 3 direct ISE
180 photometric tests per hour, 270 ISE tests per hour
14 minutes
12 minutes 30 seconds
Maximum 7.5L per hour
NCCLS type 1 or 2 purified water supply
1 hour 40 minutes
Power Requirements
Input Voltage
Power Consumption
UPS Requirements
100 -240Vac
<700 W
1.35KW
Catalogue No./ Ordering Info.
RX daytona analyser without ISE
RX daytona analyser with ISE
RX3900
RX3901
RANDOX International Headquarters
Randox Laboratories Limited, 55 Diamond Road, Crumlin, Co. Antrim, United Kingdom, BT29 4QY
T +44 (0) 28 9442 2413 F +44 (0) 28 9445 2912 E marketing@randox.com
I www.randox.com
Randox have sales and distribution agreements in over 130 countries. Australia, Brazil, China, Czech Republic, France, Germany,
Hong Kong, India, Italy, Jamaica, Poland, Portugal, Puerto Rico, Russia, Slovakia, South Africa, South Korea, Spain,
Switzerland, USA and Vietnam are directly represented by Randox Companies
Australia
Brazil
China
Randox (Australia) Pty Ltd.
Suite 2/4 Charles Street,
Paramatta, NSW 2150, Australia.
Randox Brasil Ltda
Rua Fernandes Moreira, 415
CEP: 04716-000 - So Paulo / SP - Brasil.
Tel: +61 (0) 2 9615 4640
Fax: +61 (0) 2 9615 4644
Tel: +55 11 5181-2024
Fax: +55 11 5181-0817
Randox Laboratories Ltd.
Shanghai Representative Office
Room 522-523, Fortune Times Tower, No.1438 North,
Shanxi Road, Putuo District, Shanghai, China 20060
Tel: +86 021 6288 6240
Fax: +86 021 6288 6246
Czech Republic
France
Germany
Randox S.R.O.
BHM, Sovadinova 7,
69002 Breclav 2, Czech Republic.
Laboratoires Randox
Roissy Parc, ZAC du Moulin
24-26 rue du Noyer, 95700 Roissy en France
Randox Laboratories GmbH
Wilhelmstr. 147a, 42489 Wlfrath, Germany.
Tel/Fax: +420 (0) 519 325 130
Tel: +33 (0) 130 18 96 80
Fax: +33 (0) 130 18 0360
Tel: +49 (0) 2151/93 706-11
Fax: +49 (0) 2151/ 93 706-222
Hong Kong
India
Italy
Randox Laboratories Hong Kong
Room 602, Skyline Commercial Centre,
No 71-77 Wing Lok Street, Sheung Wan, Hong Kong
Randox Laboratories India Pvt Ltd.
3rd Floor, Godrej Coliseum, Somaiya Hospital Road,
Off. Eastern Express Highway, Sion (East), Mumbai - 400 022, India
Randox Laboratories Ltd.
Corso Montevecchio 37,
10129 Torino, Italy.
Tel: +852 3595 0515
Fax: +852 3008 5133
Tel: +91 22 6714 0600
Fax: +91 22 2408 3803
Tel: +39 06 9896 8954
Fax: +39 06 6051 3810
Poland
Portugal
Puerto Rico
Randox Laboratories
ul. Wolnosc 7 lok. 15, 01-018, Warszawa.
Irlandox Laboratorios Quimica Analitica Ltda
Rua Agostinho de Jesus e Sousa 258,
4000-015 Porto, Portugal.
Randox de Puerto Rico
PMB 590 PO Box 29029 San Juan,
PR 00929-0029.
Tel: +351 22 589 8320
Fax: +351 22 589 8329
Tel: +1 787 701 7000
Fax: +1 787 701 6901
Tel: +48 (0) 22 862 1080
Fax: +48 (0) 22 862 1081
Republic of Ireland
Slovakia
South Africa
Randox Teoranta
Meenmore, Dungloe,
Co Donegal, Republic of Ireland
Randox S.R.O.
Vilov 2, 851 01 Bratislava, Slovakia.
Randox Laboratories (SA) (PTY) Ltd
Unit 69F Allandale Business Park
Cnr. Le Roux Avenue & Morkels Close
Halfway House, Midrand, South Africa
Tel: +353 7495 22600
Tel: +421 2 6381 3324
Fax: +421 2 6381 2482
Tel: +27 011 461 371
South Korea
Spain
Switzerland
Randox Korea Ltd.
904 Doosan Venturedime 126-1, Pyeongchon,
Dongan-gu, Anyang City, Kyeonggi-do, South Korea
Laboratorios Randox S.L.
C/Enric Prat de la Riba, 226, 1 Planta,
08901 LHospitalet de Llobregat, Barcelona.
Randox Laboratories Ltd. (Switzerland)
C/O Wirtschafts-Treuhand Auctor Schwyz AG,
Oberer Steisteg 18, 6430 Schwyz, Switzerland.
Tel: +82 (0) 31 478 3121
Fax: +82 (0) 31 478 3122
Tel: +34 93 475 09 64
Fax: +34 93 475 09 65
Tel: +41 41 810 48 89
Fax: +41 41 810 48 34
UK
USA
Vietnam
Randox Laboratories Ltd.
55 Diamond Road, Crumlin, Co. Antrim,
United Kingdom, BT29 4QY
Randox Laboratories-US, Ltd.
515 Industrial Boulevard, Bardane Industrial Park,
Kearneysville, West Virginia, 25430
Randox Laboratories Ltd.Vietnam
Villa Phuc Thinh 2Bis Nguyen Thi Minh Khai St.
Dakao Ward, District 1, Ho Chi Minh City,Vietnam.
Tel: +44 (0) 28 9442 2413
Fax: +44 (0) 28 9445 2912
Tel: +1 304 728 2890 Toll Free: 866 4 RANDOX
Fax: +1 304 728 1890 Toll Free: 866 RANDOX 1
Tel: +84-8-39 11 09 04
Fax: +84-8-39 11 09 05
Randox Laboratories-US Limited, 515 Industrial Boulevard, Bardane Industrial Park, Kearneysville,West Virginia, 25430
t +1 304 728 2890 Toll Free: 866 4 RANDOX f +304 728 1890 Toll Free: 866 RANDOX 1
Information correct at time of print. All Randox products are made in the UK.
Randox Laboratories Limited is a company registered within Northern Ireland with company number N.I. 15738. VAT Registered Number: GB 353 030 400. Product availability may vary from country to country. Please contact your local Randox representative for information.
LT090 OCT11
Randox Laboratories Limited, 55 Diamond Road, Crumlin, County Antrim, BT29 4QY, United Kingdom
t +44 (0) 28 9442 2413 f +44 (0) 28 9445 2912 e marketing@randox.com I www.randox.com