PowerHA SystemMirror Common Tasks
for HA Administrators
Session ID: 41CO
Michael Herrera
PowerHA SystemMirror (HACMP) for AIX
ATS Certified IT Specialist
mherrera@us.ibm.com
2010 IBM Corporation
IBM Power Systems
Agenda
Management:
Start & Stop of cluster services
Moving Resources
Saving off Configuration
Maintenance
Configuration Optimization
Hostname Changes
Naming requirements in V7.x
Auto start or not of cluster
services
Dynamic Node Priority
Application Monitoring
DLPAR Integration
Resource Group Dependencies
Upgrading AIX & Cluster Software
CSPOC - LVM Changes
Adding / Removing Physical volumes
Tunables
Network Changes (dynamic)
Cluster Security
Setting up Pager Notification
Failure Detection Rate (FDR)
Deploying File Collections
Adding Users
Custom Cluster Verification Methods
Password Changes
Practical use of UDE events
Common Commands (CLI)
Online Planning Worksheets
clmgr, lscluster
2010 IBM Corporation
IBM Power Systems
How do you check what version of code you are running ?
Historically we have run:
# lslpp l cluster.es.server.rte
Fileset
Level State
Description
---------------------------------------------------------------------------Path: /usr/lib/objrepos
cluster.es.server.rte
7.1.1.1 COMMITTED Base Server Runtime
Path: /etc/objrepos
cluster.es.server.rte
7.1.1.1 COMMITTED Base Server Runtime
Now you can also run:
# halevel s
7.1.1 SP1
even though machine may be running SP2
Also useful:
# lssrc ls clstrmgrES | grep fix
cluster fix level is "3"
Attention:
Be aware that HA 7.1.1 SP2 or SP3 does not get reported back properly. The halevel command
probes with the wrong option and since the server.rte fileset is not updated it will not catch the
updates to the cluster.cspoc.rte filesets.
3
2010 IBM Corporation
IBM Power Systems
Upgrade Considerations
There are two main areas that you need to consider OS & HA Software
Change Controls: what is your ability to apply and test the updates ?
Consider things like Interim Fixes locking down the system
Will they need to be reapplied?
Will they need to be rebuilt?
Operating System:
Should you do AIX first or HA code?
Should you combine the upgrade
New OS requirements for HA
What is your back-out plan?
Alternate disk install
Mksysb
BOS updates will typically require a
reboot (hence a disruption)
Cluster Software Code:
What type of Migration
Snapshot Migration
Rolling Migration
Non-Disruptive Update
Evaluate source to target level
Can you perform a NDU update?
New minimum OS requirements
New required settings
IP Multicasting, Hostname restrictions
Required topology changes
2010 IBM Corporation
IBM Power Systems
AIX Upgrade Flow in Clustered Environment
Hypothetical Example 2 Node Cluster running AIX 7.1
Active Production Environment
- Operating System @ AIX 7.1.0.0
You can start the upgrade on either node
but obviously an update to the node
hosting the application would cause a
disruption to operations
Starting Point Standby System
Operating System @ AIX 7.1.0.0
- Stop Cluster Services
- OS update TL1 & SPs
- Reboot
Reintegrate into cluster with AIX 7.1.1.5
- Stop with Takeover
- Acquire Resource Group / Application
- OS update TL1 & SPs
- Reboot
- Reintegrate into cluster with AIX 7.1.1.5
Standby System running New Level
- Issue rg_move back or continue to run on
the standby System
Common Question: Can the cluster run with the nodes running different levels?
5
2010 IBM Corporation
IBM Power Systems
Flow of PowerHA Software Upgrade
Hypothetical Example 2 Node Cluster HA version 5.5 to 6.1
Active Production Environment
- HA Version 5.5
- UNMANAGE resources
- Application is still running
- smit update_all
- HA Level & Patches
- Be mindful of new base filesets
- smit clstart
- Start scripts will get reinvoked
Starting Point Standby System
HA Version @ HA Version 5.5
We advise against stopping the
cluster with the UNMANAGE option
on more than one node at a time.
Note that it can be done but there
are various factors to consider
Node Running at New 6.1 version
- Application still active
- UNMANAGE resources
- smit update_all
- smit clstart
Node Running Version 6.1
Common Question: How long can the cluster run in a mixed mode ? What operations are supported ?
6
2010 IBM Corporation
IBM Power Systems
Client Scenario Database Binary Upgrade
Scenario:
- Client had an environment running independent Oracle databases in a mutual takeover cluster
configuration. They wanted to update the Oracle binaries one node at a time and wanted to avoid
an unexpected fallover during the process. They wished to UNMANAGE cluster resources on all
nodes at the same time.
Lessons Learned:
Do not do an upgrade of the cluster filesets while unmanaged on all nodes
This would recycle the clstrmgrES daemon and the cluster would lose its internal state
Application monitors are not suspended when you UNMANAGE the resources
If you manually stop the application and forget about the monitors existing application
monitors could auto-restart it or initiate a takeover depending on your configuration
Application Start scripts will get invoked again on restart of cluster services
Be aware of what happens when you invoke your start script while already running, or
comment out the scripts prior to restarting cluster services
Leave the Manage Resources attribute set to Automatic
Otherwise it will continue to show the RG as UNMANAGED until you do an RG move
ONLINE
7
2010 IBM Corporation
IBM Power Systems
PowerHA SystemMirror: Cluster Startup Behavior
What is the Best Practice ?
All currently supported
releases perform a
cluster verification on
start up and will validate
whether the node can
enter the cluster
Cluster Services are
set to automatically
start up on boot up
2010 IBM Corporation
IBM Power Systems
PowerHA SystemMirror - Cluster Start up Behavior
The cluster manager daemon is now running all of the time
# clshowsrv -v
Status of the RSCT subsystems used by HACMP:
Subsystem
Group
PID
Status
cthags
cthags
4980948
active
ctrmc
rsct
4063376
active
Status of the HACMP subsystems:
Subsystem
Group
PID
clstrmgrES
cluster
4915234
clcomd
caa
6422738
# lssrc -ls clstrmgrES | grep state
Current state: ST_STABLE
Status
active
active
Status of the optional HACMP subsystems:
Subsystem
Group
PID
Status
clinfoES
cluster
8847544
active
- Default Start up behavior is false
- Verify Cluster should be left to true
Settings can be altered within the cluster panels:
2010 IBM Corporation
IBM Power Systems
So how do you start up Cluster Services ?
smitty sysmirror System Management PowerHA SystemMirror Services Start / Stop
smitty clstart (FastPath)
clmgr start cluster
clmgr online node nodeA
clmgr start node nodeA
IBM Systems Director Plug-In
10
2010 IBM Corporation
IBM Power Systems
PowerHA SystemMirror: Cluster Stop Options
What is the purpose of each option ?
For non-disruptive updates
stop services on only one
node at a time to allow for
one node to retain the status
of the cluster resources
You cannot Non-Disruptively upgrade from pre-version 7.X to newer releases
The upgrade from 7.1.0 to 7.1.1 is also disruptive
11
2010 IBM Corporation
IBM Power Systems
UNMANAGE Resource Group Feature in PowerHA
Function used for Non-Disruptive Updates (one node at a time)
Previously known as the Forced Stop
HA Daemons will continue to run but resources will not be monitored
Application
Monitors will
continue to run.
Depending on the
implementation it
might be wise to
suspend monitors
prior to this
operation
12
2010 IBM Corporation
IBM Power Systems
Moving Resources between Nodes
clRGmove g <RGname> n <nodename> -m
clmgr move rg <RGname> node=<nodename>
If multiple RGs are selected
the operation and resources
will be processed
sequentially
IBM Systems Director Plug-In
smitty cl_admin
13
2010 IBM Corporation
IBM Power Systems
Types of Available RG Dependencies
Parent Child Dependencies
Made Available in V5.2
Location Dependencies
Made Available in V5.3
Online on Same Node
Online on Different Nodes
Online on Same Site
Start After & Stop After
Made Available in V7.1.1
Most of this is old news, but the use of dependencies can affect where and how
the resources get acquired. More importantly it can affect the steps required to
move resource groups and more familiarity with the configuration is required
14
2010 IBM Corporation
IBM Power Systems
Moving Resource Groups with Dependencies
Invoked
clRGmove g <RGname> n <nodename> -m
15
2010 IBM Corporation
IBM Power Systems
Automatic Corrections on Verify & Sync
There are Verify & Sync options in the first two
paths, however, note that they do not include
the Auto-Corrective option. You need to follow
the Custom Cluster Configuration Path for that.
The custom path will allow to make corrective
actions only if ALL cluster nodes are not running
cluster services. By default it will not perform
any corrective actions.
16
2010 IBM Corporation
IBM Power Systems
Automatic Nightly Cluster Verification
By Default the cluster will run a nightly Verification check at midnight
Be aware of the
clcomd changes for
version 7 clusters
The clutils.log file should show the results of the nightly check
17
2010 IBM Corporation
IBM Power Systems
Cluster Custom Verification Methods
Cluster Verification is made up of a bunch of data collectors
Checks will return PASSED or FAILED
Will often provide more details than what is reported in the smit.log output
Custom Verification Methods may be defined to run during the Verify / Sync operations
Note: Automatic verify & sync on node start up does not include any custom verification methods
18
2010 IBM Corporation
IBM Power Systems
Adding Custom Verification Methods
Problem Determination Tools > PowerHA SystemMirror Verification > Configure Custom Verification Method
Add a Custom Verification Method and press Enter
Output in smit.log and clverify.log files:
Currently Loaded Interim Fixes:
NODE mutiny.dfw.ibm.com
PACKAGE
INSTALLER LABEL
======================================================== =========== ==========
bos.rte.security
installp passwdLock
NODE munited.dfw.ibm.com
PACKAGE
INSTALLER LABEL
======================================================== =========== ==========
bos.rte.security
installp passwdLock
Please Ensure that they are consistent between the nodes!
19
2010 IBM Corporation
IBM Power Systems
Custom Verification Methods
Custom methods should be in a common path between the cluster members
ie. /usr/local/hascripts/custom_ver_check.sh
The Methods are stored in the cluster ODM stanzas
Script Logic & Return Codes
How fancy do you want to get
20
#!/bin/ksh
echo "Currently Loaded Interim Fixes:"
clcmd emgr -P
echo "Please Ensure that they are consistent between the nodes!"
2010 IBM Corporation
IBM Power Systems
PowerHA SystemMirror: Cluster Snapshots
/usr/es/sbin/cluster/snapshots/ <snapshotname>.info
<snapshotname>.odm
Snapshot files:
Snapshot C .odm
Snapshot
cluster B .odm
ODM stanzas
cluster
Snapshot A .odm
ODM stanzas
cluster
ODM stanzas
21
Snapshot C .info
Snapshot
cluster
reportB .info
Snapshots are saved
off automatically any
time a Verify / Sync
operation is invoked
Snapshot
cluster
reportA .info
cluster report
Cluster Configuration
Cluster Report & CLI output
HACMPcluster
...infoT
<html tags>
cllsnode
T..
HACMPnode
TinfoT
cllscf
T..
HACMPadapter
TinfoT.
cllsif
T..
The .info file is not
necessary in order to
able to restore the
configuration
The snapshot menu will
ask for a <name> and a
<description> as the
only required fields
The snapshot upgrade
migration path requires
the entire cluster to be
down
2010 IBM Corporation
IBM Power Systems
PowerHA SystemMirror: Changing the Hostname
CAA does not currently support changing a systems hostname
Basically means do not attempt to do this in a Version 7.X cluster
Inet0 - hostname
Inet0 - hostname
Only the service IP should
be swapping between nodes
# lscluster output
TT.
UUID as well
Service IP
Volume Group
/filesystems
start.sh
#!/bin/ksh
set new Hostname
stop.sh
#!/bin/ksh
unset hostname
Application
Controller
The same is true for
the cluster repository
disk. The UUID is
stored hence you
should not attempt to
replicate the volume
or create an mirrors
to the volume
caa_private volume
group.
* This is restriction currently under evaluation by the CAA development team and may
be lifted in a future update
22
2010 IBM Corporation
IBM Power Systems
Naming requirements in V7 clusters
The COMMUNICATION_PATH has to resolve to the hostname IP
In prior releases the CP could be any path to the node
Node name can be different than the hostname
The use of a - is not supported in the node name
We had clients further highlight this limitation by using clmgr to create the
cluster. If a node name is not specified and the hostname has a - the default
node name assigned will also try to use a -
ksh restrictions were removed to allow the use of a - in service IP labels so
both V6.1 and V7.X support their use in the name
23
2010 IBM Corporation
IBM Power Systems
Changes to Node outbound traffic
There were changes made to AIX & PowerHA alias processing
Cluster running HA V6.1 SP7
with AIX 6.1 TL2
Service IP Alias is listed after
persistent & base address
Cluster running HA V7.1 SP3
with AIX 7.1 TL1 SP4
Service IP Alias is automatically
listed before the base address.
Note that no persistent IP is
configured in this environment
24
2010 IBM Corporation
IBM Power Systems
Number of Resources & Fallover Times
Common Questions:
Will the number of disks or volume groups affect my fallover time?
Should I configure less larger luns or more smaller luns?
Versions 6.1 and earlier allowed Standard VGs or Enhanced Concurrent VGs
Version 7.X require the use of ECM volume groups
Your Answers:
Standard VGs would require an openx call against each physical volume
Processing could take several seconds to minutes depending on the number of LUNs
ECM VGs are varied on all nodes (ACTIVE / PASSIVE)
It takes seconds per VG
Parallel processing will attempt to varyon on all VGs in parallel
25
2010 IBM Corporation
IBM Power Systems
Number of Resource Groups
RG Decisions beyond: Startup Fallover & Fallback behavior
NODE A
RG1 (NodeA, NodeB)
Service IP
VG1
APP Server 1
NODE B
RG2 (NodeB, NodeA)
Service IP
VG2
APP Server 2
Further Options
1 RG vs. Multiple RGs
Selective Fallover behavior (VG / IP)
RG Processing
Parallel vs. Sequential
RG3 (NodeA, NodeB)
Service IP
VG3
APP Server 3
RG4 (NodeB, NodeA)
Service IP
VG4
APP Server 4
Delayed Fallback Timer
When do you want to fail back
RG Dependencies
Parent / Child, Location
Start After / Stop After
Best Practice:
Always try to keep it simple, but stay current with new features and take advantage
of existing functionality to avoid added manual customization.
26
2010 IBM Corporation
IBM Power Systems
Filesystem Definitions in a Resource Group
Should you explicitly define the filesystems in a Resource Group?
PowerHA default behavior is to mount ALL
Reasons to explicitly define:
Nested Filesystems
Only mount Filesystems specified
Scenario:
10 Filesystems in volume group & only 1 defined in RG
HA processing will only mount the one FS
27
What are the implications going
forward if you add new Filesystems
via CSPOC and forget to append
them to the resource group
definition?
2010 IBM Corporation
IBM Power Systems
Event Processing of resources
Resource Groups are processed in Parallel unless you implement RG dependencies or
set a customized serial processing order (HA 4.5 +)
The new process_resources event script is organized around job types: ACQUIRE,
RELEASE, ONLINE, OFFLINE, DISKS, TAKEOVER_LABELS, APPLICATIONS and more
i.e. JOB_TYPE = VGS
Invoked during Parallel Processing:
acquire_svc_addr
acquire_takeover_addr
node_down
node_up
release_svc_addr
release_takeover_addr
start_server
stop_server
28
* Be mindful of this with the implementation of Pre/Post Events
Not invoked:
get_disk_vg_fs
node_down_local
node_down_remote
node_down_local_complete
node_down_remote_complete
node_up_ local
node_up_remote
node_up_local_complete
node_up_remote_complete
release_vg_fs
2010 IBM Corporation
IBM Power Systems
Defining Pre / Post Events
Pre/Post-Event Commands are NOT the same thing as User Defined Events
A custom Event will never
get invoked unless you
explicitly define it as a Pre or
Post event command to an
existing Cluster Event
29
2010 IBM Corporation
IBM Power Systems
User Defined Events - UDE
This option allows you to exploit RMC resource monitors to trigger EVENTs
Familiarize yourself with the lsrsrc command
A Practical Guide for Resource Monitoring and Control - SG24-6615
Notes:
Recycle cluster services after updating UDE events
Scripts must exist on all cluster nodes: (Path, permissions)
Logic in recovery program can be configured to send
notification, append more space, etcT
Can specify multiple values in Selection String field
Actions logged in clstrmgr.debug and hacmp.out files
30
# odmget HACMPude
HACMPude:
name = "Herrera_UDE_event"
state = 0
recovery_prog_path =
"/usr/local/hascripts/Herrera_UDE
recovery_type = 2
recovery_level = 0
res_var_name = "IBM.FileSystem"
instance_vector = "Name = \"/\""
predicate = "PercentTotUsed > 95"
rearm_predicate = "PercentTotUsed < 70"
2010 IBM Corporation
IBM Power Systems
PowerHA SystemMirror: File Collections
Introduced in HA 5.2
Ability to automatically push files every 10 min from source node specified
Default collections created but not enabled by default
Configuration_Files
/etc/hosts
/etc/services
/etc/snmpd.conf
/etc/snmpdv3.conf
/etc/rc.net
/etc/inetd.conf
/usr/es/sbin/cluster/netmon.cf
/usr/es/sbin/cluster/etc/clhosts
/usr/es/sbin/cluster/etc/rhosts
/usr/es/sbin/cluster/etc/clinfo.rc
SystemMirror_Files
Pre, Post & Notification
Start & Stop scripts
Scripts specified in monitors
Custom pager text messages
SNA scripts
Scripts for tape support
Custom snapshot methods
User defined events
Not intended to maintain users & passwords between cluster nodes
31
2010 IBM Corporation
IBM Power Systems
File Collections Application script Scenario
# smitty sysmirror System Management File Collections
If set to yes files
will be propagated
every 10 minutes
Node A
/usr/local/hascripts/app*
/usr/local/hascripts/app*
#!/bin/ksh
Application Start Logic
#!/bin/ksh
Application Start Logic
RED Updates
#!/bin/ksh
Application Stop Logic
BLUE Logic
#!/bin/ksh
Application Stop Logic
RED Updates
32
Node B
Blue Logic
2010 IBM Corporation
IBM Power Systems
PowerHA SystemMirror - User & Group Administration
# smitty sysmirror System Management Security and Users
Can select
Local (files)
LDAP
Select Nodes by
Resource Group
No selection
means all nodes
Users will be
propagated to all of
the cluster nodes
applicable
Password command
can be altered to
ensure consistency
across al nodes
33
2010 IBM Corporation
IBM Power Systems
PowerHA SystemMirror - User Passwords (clpasswd)
# smitty sysmirror System Management Security and Users Passwords in a PowerHA SystemMirror cluster
Optional List of
Users whose
passwords will be
propagated to all
cluster nodes
passwd
command is
aliased to
clpasswd
Functionality
available since
HACMP 5.2
(Fall 2004)
34
2010 IBM Corporation
IBM Power Systems
Repository Disk Failure
35
2010 IBM Corporation
IBM Power Systems
Pager Notification Events
As long as sendmail is enabled you can easily receive EVENT notification
smitty sysmirror Custom Cluster Configuration Events Cluster Events
Remote Notification Methods Add a Custom Remote Notification Method
Sample Email:
From: root 10/23/2012 Subject: HACMP
Node mhoracle1: Event acquire_takeover_addr occurred at Tue Oct 23 16:29:36 2012, object =
36
2010 IBM Corporation
IBM Power Systems
Pager Notification Methods
HACMPpager:
methodname = "Herrera_notify"
desc =
Lab Systems Pager Event"
nodename =
"connor kaitlyn"
dialnum =
"mherrera@us.ibm.com"
filename =
"/usr/es/sbin/cluster/samples/pager/sample.txt"
eventname =
"acquire_takeover_addr config_too_long
event_error node_down_complete node_up_complete"
retrycnt =
3
timeout =
45
# cat /usr/es/sbin/cluster/samples/pager/sample.txt
Node %n: Event %e occurred at %d, object = %o
Action Taken: Halted Node Connor
Sample Email:
From: root 09/01/2009 Subject: HACMP
Node kaitlyn: Event acquire_takeover_addr occurred at Tue Sep 1 16:29:36 2009, object =
Attention:
Sendmail must be working and accessible via the firewall to receive notifications
37
2010 IBM Corporation
IBM Power Systems
Online Planning Worksheets Discontinued in Version 7
The fileset is still there, but the content is no longer there
There is a push to
leverage IBM Systems
Director which will guide
you through the step by
step configuration of the
cluster
38
2010 IBM Corporation
IBM Power Systems
PowerHA SystemMirror Deadman Switch (CAA)
Version 7 cluster software changes the old behavior
Recent Client Failure Scenario
TT..............
- Repository Disk LUN had been
locked and had not been
responsive for days. Client was
unaware and standby node had a
problem. Primary system was
brought down when it was unable
to write to repository disk
CAA DMS tunable (deadman_mode) allows two different actions
Assert (crash) the system (default behavior)
Generate AHAFS event
39
2010 IBM Corporation
IBM Power Systems
LVM Dynamic Updates
The cluster is easy to set up, but what about changes going forward
ECM Volume Groups (required at HA V7)
New lvs will get pushed across, filesystems will not
LV updates get pushed across but do not update the /etc/filesystems.
Lazy Update would resolve this issue
ECM Limitations lifted for:
reorgvg & chvg -g size changes
Cluster Import Option
Correcting out of sync timestamps auto-corrections or import
Built-In Lazy Update
40
2010 IBM Corporation
IBM Power Systems
CSPOC allows for a multitude of DARE operations
The Cluster Single Point of Control options facilitate dynamic operations
# smitty cl_admin
Follow these panels to
dynamically add or remove
resources from the cluster or
perform resource group
movements between nodes
There are CSPOC specific
logs in the HA cluster that will
provide details in the event of
a problem
41
2010 IBM Corporation
IBM Power Systems
CSPOC: Storage & LVM Menus
42
2010 IBM Corporation
IBM Power Systems
Tunable Failure Detection Rate in 7.1.1
Note that the SMIT menu to alter values was missing prior to HA 7.1.1 SP1
Attributes stored
in HACMPcluster
object class
Checking current settings:
root@mhoracle1 /> clctrl -tune -o node_down_delay
sapdemo71_cluster(07552a84-057b-11e1-b7cb-46a6ba546402).node_down_delay = 10000
root@mhoracle1 /> clctrl -tune -o node_timeout
sapdemo71_cluster(07552a84-057b-11e1-b7cb-46a6ba546402).node_timeout = 20000
Modifying via command line:
clmgr modify cluster HEARTBEAT_FREQUENCY= 10000 GRACE_PERIOD=5000
*** The settings will take effect only after the next sync
43
2010 IBM Corporation
IBM Power Systems
FDR Comparison to Version 6.1 & earlier versions
RSCT (topsvcs)
CAA
Heartbeat settings can be defined for each
network type (nim).
Heartbeat settings are same for all networks
in the cluster.
One perspective is that we only support
Ethernet networks.
The settings for heartbeat are
Grace period
Failure Cycle
Interval between Heartbeats
The settings for heartbeat are
Grace period (5 - 30 Seconds)
Failure cycle (1 - 20 seconds)
The combination of heartbeat rate and failure
cycle determines how quickly a failure can be
detected and may be calculated using this
formula:
(heartbeat rate) * (failure cycle) * 2 seconds
Failure cycle is the time that another node
may consider the adapter to be DOWN if it
receives no incoming heartbeats.
Actual heartbeat rate is calculated
depending on the Failure cycle.
Grace period is the waiting time period after
detecting the Failure before it is reported.
Grace period is the waiting time period after
detecting the Failure before it is reported.
*** Note that HA 7.1.0 had self-tuning failure detection rate
2010 IBM Corporation
IBM Power Systems
Application Monitoring within PowerHA SystemMirror
Some are provided in Smart Assistants
ie. cluster.es.assist.oracle /usr/es/sbin/cluster/sa/oracle/sbin/DBInstanceMonitor
A Monitor is bound to the Application Controller
Example OracleDB
Startup
Monitor
Only
invoked on
application
startup
Confirm the
startup of the
application
New
Application
Startup Mode
in HA 7.1.1
45
Process
Monitor
Custom
Monitor
60 sec
interval
60 sec
interval
Long Running Monitors will
continue run locally with the
running application
Checks the
process table
Invokes the
custom logic
2010 IBM Corporation
IBM Power Systems
PowerHA SystemMirror: Application Startup 7.1.1
The cluster invokes the start script but doesnt confirm its success
Consider at least an application start up monitor
Resource Group A
Service IP
Enhancement was introduced in HA Version 7.1.1
- Application start may be set to run in the foreground
Volume Group
/filesystems
start.sh
Application
Controller
stop.sh
Start up Monitor
Long-Running Monitor
46
2010 IBM Corporation
IBM Power Systems
PowerHA SystemMirror HMC Definition
There was no
SDMC support.
No longer much
of an issue
Information
stored in HA
ODM object
classes
Multiple HMC
IPs may be
defined
separated by a
space
Food for Thought: How many DLPAR operations can be handled at once?
47
2010 IBM Corporation
IBM Power Systems
PowerHA SystemMirror Integrated DLPAR Menu
Add Dynamic LPAR and CoD Resources for Applications
HMC
Type or select values in entry fields.
Press Enter AFTER making all desired changes.
[TOP]
* Application Controller Name
[Entry Fields]
Application_svr1
* Minimum number of processing units
* Desired number of processing units
HMC IPs are
defined and stored
in a different HA
panel
[ 0.00]
[ 0.00]
* Minimum number of CPUs
* Desired number of CPUs
[0]
[0]
#
#
* Minimum amount of memory (in megabytes)
* Desired amount of memory (in megabytes)
[0]
[0]
#
#
* Use CoD if resources are insufficient?
[no]
* I agree to use CoD resources
(Using CoD may result in extra costs)
[no]
You must ensure that
* CoD enablement keys are activated
* CoD resources are not used for any other purpose
48
2010 IBM Corporation
IBM Power Systems
The many uses of the clmgr utility
V7 Clustering introduces many applications for this command
# clmgr add cluster clmgr_cluster REPOSITORY=hdisk2 CLUSTER_IP=228.1.1.36
# clmgr add node clmgr2
Add a new cluster
Add a new node
# clmgr add network net_ether_01 TYPE=ether
# clmgr add interface clmgr2b2 NETWORK=net_ether_02 NODE=clmgr2 INTERFACE=en1
# clmgr add persistent clmgr1p1 NETWORK=net_ether_01 NODE=clmgr1
# clmgr add service_ip clmgrsvc1 NETWORK=net_ether_01
# clmgr add application_controller test_app1 STARTSCRIPT="/home/apps/start1.sh"
STOPSCRIPT="/home/apps/stop1.sh" STARTUP_MODE=background
Add an Application
Controller
# clmgr add volume_group test_vg1 NODES="clmgr1,clmgr2" PHYSICAL_VOLUMES=hdisk3
TYPE=original MAJOR_NUMBER=35 ACTIVATE_ON_RESTART=false
# clmgr add resource_group clmgr_RG1 NODES="clmgr1,clmgr2" STARTUP=OHN
FALLOVER=FNPN FALLBACK=NFB VOLUME_GROUP=test_vg
SERVICE_LABEL=clmgrsvc1 APPLICATIONS=test_app1
Add a new
Resource Group
# clmgr verify cluster CHANGES_ONLY=no FIX=yes LOGGING=standard
# clmgr sync cluster CHANGES_ONLY=no FIX=yes LOGGING=standard
Verify / Sync cluster
# clmgr online cluster WHEN=now MANAGE=auto BROADCAST=true CLINFO=true
Start Cluster Services
# clmgr modify clusterNAME=my_new_cls_label
# clmgr manage application_controller suspend test_app1 RESOURCE_GROUP="clmgr_RG1"
# clmgr manage application_controller resume test_app1 RESOURCE_GROUP="clmgr_RG2"
49
Change cluster name
Suspend / Resume
Application Monitors
2010 IBM Corporation
IBM Power Systems
Summary
There are some notable differences between V7 and HA 6.1 and earlier
Pay careful attention to where some of the options are available
Appended Summary Chart of new features to the presentation
Version 7.1.2 Scheduled GA on Nov 9th
Brings Enterprise Edition to V7 clusters
This session is an attempt to make you aware of available options in
PowerHA
Take my recommendations with a grain of salt!
Take advantage of integrated features & interfaces like:
Application monitoring infrastructure
File Collections
Pre/Post Events and User Defined Events
Pager Notification Methods
New clmgr CLI
SG24-8030
50
2010 IBM Corporation
IBM Power Systems
Summary Chart
New Functionality & Changes
New CAA Infrastructure
Disk Fencing Enhancements
Rootvg System Event
Disk rename Function
Repository Disk Resilience
IP Multicast based Heartbeat Protocol
HBA Based SAN Heartbeating
Private Network Support
Tunable Failure Detection Rate
New Service IP Distribution Policies
Full IPV6 Support
Backup Repository Disks
New Application Startup Mode
Exploitation of JFS2 Mount Guard
Adaptive Fallover
New RG Dependencies
51
Smart Assistants (Application Integration)
SAP Live Cache with DS or SVC
MQ Series
7.1.1
7.1.1
DR Capabilities
7.1.2
7.1.0
7.1.0
7.1.0
7.1.1
7.1.2
7.1.1
7.1.1
7.1.0
7.1.0
Stretch & Linked Clusters
DS8000 Hyperswap
7.1.2
7.1.2
Management
New Command Line Interface
clcmd
clmgr utility
lscluster
IBM Systems Director Management
7.1.0
7.1.0
Start After, Stop After
Federated Security
7.1.X
7.1.1
RBAC, EFS & Security System Administration
Extended Distance Clusters
XIV Replication Integration
XP12000, XP24000
HP9500
Storwize v7000
SVC 6.2
(12/16/2011)
(11/18/2011)
(8/19/2011)
(9/30/2011)
(9/30/2011)
2010 IBM Corporation
IBM Power Systems
Questions?
Thank you for your time!
52
2010 IBM Corporation
IBM Power Systems
Additional Resources
PowerHA SystemMirror 7.1.1 Update SG24-8030
http://www.redbooks.ibm.com/redpieces/abstracts/sg248030.html?Open
PowerHA SystemMirror 7.1 Redbook SG24-7845
Removed from Download site
http://www.redbooks.ibm.com/Redbooks.nsf/RedbookAbstracts/sg247845.html?Open
Disaster Recovery Redbook
SG24-7841 - Exploiting PowerHA SystemMirror Enterprise Edition for AIX
http://www.redbooks.ibm.com/abstracts/sg247841.html?Open
RedGuide: High Availability and Disaster Recovery Planning: Next-Generation Solutions for Multi
server IBM Power Systems Environments
http://www.redbooks.ibm.com/abstracts/redp4669.html?Open
PowerHA SystemMirror Marketing Page
http://www-03.ibm.com/systems/power/software/availability/aix/index.html
PowerHA SystemMirror Wiki Page
http://www-941.ibm.com/collaboration/wiki/display/WikiPtype/High+Availability
53