0% found this document useful (0 votes)
57 views762 pages

BSPLCML

bsplcml

Uploaded by

FlorencioPautang
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
57 views762 pages

BSPLCML

bsplcml

Uploaded by

FlorencioPautang
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 762

GSM/EDGE RAN - BR line

Reference
Base transceiver station equipment

BS-4x / 82 II / 240 / 241 / 240XL commands


A50016-G5100-B333-04-7619

BS-4x / 82 II / 240 / 241 / 240XL commands

The information in this document is subject to change without notice and describes only the
product defined in the introduction of this documentation. This documentation is intended for the
use of Nokia Siemens Networks customers only for the purposes of the agreement under which
the document is submitted, and no part of it may be used, reproduced, modified or transmitted
in any form or means without the prior written permission of Nokia Siemens Networks. The
documentation has been prepared to be used by professional and properly trained personnel,
and the customer assumes full responsibility when using it. Nokia Siemens Networks welcomes
customer comments as part of the process of continuous development and improvement of the
documentation.
The information or statements given in this documentation concerning the suitability, capacity,
or performance of the mentioned hardware or software products are given "as is" and all liability
arising in connection with such hardware or software products shall be defined conclusively and
finally in a separate agreement between Nokia Siemens Networks and the customer. However,
Nokia Siemens Networks has made all reasonable efforts to ensure that the instructions
contained in the document are adequate and free of material errors and omissions. Nokia
Siemens Networks will, if deemed necessary by Nokia Siemens Networks, explain issues which
may not be covered by the document.
Nokia Siemens Networks will correct errors in this documentation as soon as possible. IN NO
EVENT WILL Nokia Siemens Networks BE LIABLE FOR ERRORS IN THIS DOCUMENTATION OR FOR ANY DAMAGES, INCLUDING BUT NOT LIMITED TO SPECIAL, DIRECT, INDIRECT, INCIDENTAL OR CONSEQUENTIAL OR ANY LOSSES, SUCH AS BUT NOT LIMITED
TO LOSS OF PROFIT, REVENUE, BUSINESS INTERRUPTION, BUSINESS OPPORTUNITY
OR DATA,THAT MAY ARISE FROM THE USE OF THIS DOCUMENT OR THE INFORMATION
IN IT.
This documentation and the product it describes are considered protected by copyrights and
other intellectual property rights according to the applicable laws.
The wave logo is a trademark of Nokia Siemens Networks Oy. Nokia is a registered trademark
of Nokia Corporation. Siemens is a registered trademark of Siemens AG.
Other product names mentioned in this document may be trademarks of their respective
owners, and they are mentioned for identification purposes only.
Copyright Nokia Siemens Networks 2009. All rights reserved

Important Notice on Product Safety


Elevated voltages are inevitably present at specific points in this electrical equipment.
Some of the parts may also have elevated operating temperatures.
Non-observance of these conditions and the safety instructions can result in personal
injury or in property damage.
Therefore, only trained and qualified personnel may install and maintain the system.
The system complies with the standard EN 60950 / IEC 60950. All equipment connected
has to comply with the applicable safety standards.

The same text in German:


Wichtiger Hinweis zur Produktsicherheit
In elektrischen Anlagen stehen zwangslufig bestimmte Teile der Gerte unter Spannung. Einige Teile knnen auch eine hohe Betriebstemperatur aufweisen.
Eine Nichtbeachtung dieser Situation und der Warnungshinweise kann zu Krperverletzungen und Sachschden fhren.
Deshalb wird vorausgesetzt, dass nur geschultes und qualifiziertes Personal die
Anlagen installiert und wartet.
Das System entspricht den Anforderungen der EN 60950 / IEC 60950. Angeschlossene
Gerte mssen die zutreffenden Sicherheitsbestimmungen erfllen.

Id:0900d80580627b1d

A50016-G5100-B333-04-7619

BS-4x / 82 II / 240 / 241 / 240XL commands

Table of Contents
This document has 762 pages.
Reason for update . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19
1
1.1
1.1.1
1.1.2
1.1.3
1.1.4
1.2
1.2.1
1.2.2
1.3
1.3.1
1.3.2

Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
General . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Structure of the manual . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Structure of the commands . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Ranges for the relative number of the BTSE objects. . . . . . . . . . . . . . .
Command layout . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Graphical user interface (GUI) representation of the LMT Evolution . . .
Start LMT Evolution window . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
LMT Evolution windows for GET, CREATE, SET, ..., commands . . . . .
Command tree . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
BS240, BS241, BS240XL, BS40, BS41, BS40II and BS82II main tree
Alphabetical list of commands . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Objects and commands in alphabetical order . . . . . . . . . . . . . . . . . . . . 48

A50016-G5100-B333-04-7619

21
21
22
23
23
26
28
28
31
34
34
35

ACDCP . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
CREATE ACDCP. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
DELETE ACDCP . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
GET ACDCP . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
GETTEST ACDCP. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
LOCK ACDCP . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
PERFTEST ACDCP. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
STOPTEST ACDCP . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
UNLOCK ACDCP . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

49
49
51
52
53
55
57
60
62

ACT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
CREATE ACT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
DELETE ACT. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
GET ACT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
GETTEST ACT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
LOCK ACT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
PERFTEST ACT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
STOPTEST ACT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
UNLOCK ACT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

64
64
66
67
69
70
72
76
77

BATTERY . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
CREATE BATTERY. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
DELETE BATTERY . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
GET BATTERY . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
GETTEST BATTERY. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
LOCK BATTERY . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
PERFTEST BATTERY. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
STOPTEST BATTERY . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
UNLOCK BATTERY . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

79
79
81
82
84
86
87
91
92

Id:0900d80580627b1d

BS-4x / 82 II / 240 / 241 / 240XL commands

BCOM . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 95
CREATE BCOM . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 95
DELETE BCOM . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 99
GET BCOM. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 100
GETRELATIONSHIP BCOM . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 102
GETTEST BCOM . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 104
GETWIRINGRX BCOM . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 105
GETWIRINGTX BCOM . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 107
LOCK BCOM . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 108
PERFTEST BCOM . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 110
SET BCOM . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 114
SETWIRINGRX BCOM . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 115
SETWIRINGTX BCOM . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 118
STOPTEST BCOM . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 119
UNLOCK BCOM . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 120
BPORT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 123
CREATE BPORT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 123
DELETE BPORT. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 126
GET BPORT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 127
LOCK BPORT. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 129
SET BPORT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 131
UNLOCK BPORT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 132
BTS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 135
GET BTS. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 135
GET BTS TIMER . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 140
BTSEP . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 143
DELETE BTSEP DBFILE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 143
FORMAT BTSEP FLASH . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 144
GET BTSEP NOSWL . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 145
GET BTSEP SWL . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 148
GETACTIVEALARMS BTSEP . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 149
PERFTEST BTSEP . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 152
PING BTSEP . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 156
SET BTSEP . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 157
STOPTEST BTSEP . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 159
BTSETEST . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 161
GET BTSETEST . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 161
BTSM . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 163
ACTIVATE BTSM . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 163
ACTIVATE_DELAYED BTSM. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 165
CONNBSC BTSM . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 165
DISCBSC BTSM . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 167
FWUPGRADE BTSM . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 168
GET BTSM NOSWL . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 169
GET BTSM OVERLOAD. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 172

Id:0900d80580627b1d

A50016-G5100-B333-04-7619

BS-4x / 82 II / 240 / 241 / 240XL commands

GET BTSM SWL . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .


LOCKREQUEST BTSM. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
SET BTSM . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
SHUTDOWN BTSM. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
UNLOCKREQUEST BTSM . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

173
174
175
177
178

CESPW . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
CREATE CESPW . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
DELETE CESPW. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
GET CESPW . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
LOCK CESPW . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
SET CESPW . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
UNLOCK CESPW . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

180
180
182
183
185
187
188

CESTUNNEL . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
CREATE CESTUNNEL . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
DELETE CESTUNNEL . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
GET CESTUNNEL. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
LOCK CESTUNNEL . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
SET CESTUNNEL . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
UNLOCK CESTUNNEL . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

190
190
191
192
194
195
196

CHAN. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 198
GET CHAN . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 198

A50016-G5100-B333-04-7619

COBA. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
CREATE COBA . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
DELETE COBA . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
GET COBA . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
GETRELATIONSHIP COBA . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
GETTEST COBA . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
LOCK COBA . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
PERFTEST COBA . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
SET COBA. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
STOPTEST COBA. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
SWITCH COBA . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
UNLOCK COBA. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

200
200
202
203
205
206
208
209
213
214
216
217

COBAETHINTF . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
GET COBAETHINTF . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
LOCK COBAETHINTF. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
SET COBAETHINTF . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
UNLOCK COBAETHINTF . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

219
219
220
221
222

COSA. . . . . . . . . . .
CREATE COSA . . .
DELETE COSA . . .
GET COSA . . . . . .
GETTEST COSA . .
LOCK COSA . . . . .
PERFTEST COSA .

224
224
225
227
228
230
232

.......................................
.......................................
.......................................
.......................................
.......................................
.......................................
.......................................

Id:0900d80580627b1d

BS-4x / 82 II / 240 / 241 / 240XL commands

STOPTEST COSA . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 236


UNLOCK COSA . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 237
CU. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 239
CREATE CU . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 239
DELETE CU . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 241
GET CU . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 242
GET CU FWID . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 244
GET CU WIRING . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 245
GETTEST CU . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 246
LOCK CU . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 248
PERFTEST CU . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 249
SET CU . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 253
STOPTEST CU . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 254
UNLOCK CU. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 255
DIDCTMA . . . . . . . . . .
CREATE DIDCTMA . .
DELETE DIDCTMA. . .
GET DIDCTMA . . . . . .
GETTEST DIDCTMA .
LOCK DIDCTMA. . . . .
PERFTEST DIDCTMA
STOPTEST DIDCTMA
UNLOCK DIDCTMA . .

......
......
......
......
......
......
......
......
......

.......
.......
.......
.......
.......
.......
.......
.......
.......

......
......
......
......
......
......
......
......
......

.......
.......
.......
.......
.......
.......
.......
.......
.......

......
......
......
......
......
......
......
......
......

. . . . . 258
. . . . . 258
. . . . . 259
. . . . . 261
. . . . . 262
. . . . . 264
. . . . . 266
. . . . . 270
. . . . . 271

DILNA . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 273
CREATE DILNA . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 273
DELETE DILNA . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 275
GET DILNA . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 277
GETTEST DILNA . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 278
LOCK DILNA. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 280
PERFTEST DILNA . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 282
SET DILNA . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 286
STOPTEST DILNA . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 287
UNLOCK DILNA . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 288

DUAMCO . . . . . . . . . .
DELETE DUAMCO . . .
GET DUAMCO . . . . . .
GETTEST DUAMCO .
LOCK DUAMCO . . . . .
PERFTEST DUAMCO
STOPTEST DUAMCO
UNLOCK DUAMCO . .

......
......
......
......
......
......
......
......

.......
.......
.......
.......
.......
.......
.......
.......

......
......
......
......
......
......
......
......

.......
.......
.......
.......
.......
.......
.......
.......

......
......
......
......
......
......
......
......

. . . . . 290
. . . . . 290
. . . . . 291
. . . . . 292
. . . . . 293
. . . . . 294
. . . . . 295
. . . . . 296

DUDCTMA . . . . . . . . .
CREATE DUDCTMA .
DELETE DUDCTMA . .
GET DUDCTMA . . . . .

......
......
......
......

.......
.......
.......
.......

......
......
......
......

.......
.......
.......
.......

......
......
......
......

. . . . . 298
. . . . . 298
. . . . . 300
. . . . . 301

Id:0900d80580627b1d

A50016-G5100-B333-04-7619

BS-4x / 82 II / 240 / 241 / 240XL commands

GETTEST DUDCTMA . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
LOCK DUDCTMA . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
PERFTEST DUDCTMA . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
STOPTEST DUDCTMA . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
UNLOCK DUDCTMA . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

302
304
306
310
311

DULNA. . . . . . . . . . . . . . . .
CREATE DULNA . . . . . . . .
DELETE DULNA . . . . . . . .
GET DULNA . . . . . . . . . . .
GETTEST DULNA . . . . . . .
LOCK DULNA . . . . . . . . . .
PERFTEST DULNA . . . . . .
SET DULNA. . . . . . . . . . . .
STOPTEST DULNA. . . . . .
UNLOCK DULNA. . . . . . . .

.................................
.................................
.................................
.................................
.................................
.................................
.................................
.................................
.................................
.................................

313
313
315
317
319
321
322
326
328
329

DUVSWR . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
CREATE DUVSWR . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
DELETE DUVSWR . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
GET DUVSWR. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
GETTEST DUVSWR . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
LOCK DUVSWR . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
PERFTEST DUVSWR . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
SET DUVSWR . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
STOPTEST DUVSWR . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
UNLOCK DUVSWR . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

331
331
333
335
336
338
340
344
345
346

ENVABTSE . . . . . . . . . . . .
CREATE ENVABTSE . . . .
DELETE ENVABTSE. . . . .
GET ENVABTSE . . . . . . . .
LOCK ENVABTSE . . . . . . .
SET ENVABTSE . . . . . . . .
UNLOCK ENVABTSE . . . .

.............
.............
.............
.............
.............
.............
.............

349
349
353
354
356
358
359

.......................................
.......................................
.......................................
.......................................
.......................................
.......................................
.......................................

361
361
362
362
364
365
366

ETHCON . . . . . . . .
CREATE ETHCON
DELETE ETHCON.
GET ETHCON . . . .
LOCK ETHCON . . .
SET ETHCON . . . .
UNLOCK ETHCON

ETHPORT . . . . . . . . . . . . .
CREATE ETHPORT . . . . .
DELETE ETHPORT. . . . . .
GET ETHPORT . . . . . . . . .
LOCK ETHPORT . . . . . . . .
SET ETHPORT . . . . . . . . .

A50016-G5100-B333-04-7619

.......
.......
.......
.......
.......
.......
.......

......
......
......
......
......
......
......

.......
.......
.......
.......
.......
.......
.......

.................................
.................................
.................................
.................................
.................................
.................................

Id:0900d80580627b1d

368
368
369
370
372
373

BS-4x / 82 II / 240 / 241 / 240XL commands

UNLOCK ETHPORT. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 374

F6DCTMA . . . . . . . . . . . . . . . .
CREATE F6DCTMA . . . . . . . .
DELETE F6DCTMA . . . . . . . .
GET F6DCTMA. . . . . . . . . . . .
GETTEST F6DCTMA . . . . . . .
LOCK F6DCTMA . . . . . . . . . .
PERFTEST F6DCTMA . . . . . .
STOPTEST F6DCTMA . . . . . .
UNLOCK F6DCTMA . . . . . . . .

.......
.......
.......
.......
.......
.......
.......
.......
.......

......
......
......
......
......
......
......
......
......

.......
.......
.......
.......
.......
.......
.......
.......
.......

......
......
......
......
......
......
......
......
......

F6LNA . . . . . . . . . . . . .
CREATE F6LNA . . . . .
DELETE F6LNA . . . . .
GET F6LNA . . . . . . . .
GETTEST F6LNA . . . .
LOCK F6LNA . . . . . . .
PERFTEST F6LNA . . .
SET F6LNA. . . . . . . . .
STOPTEST F6LNA. . .
UNLOCK F6LNA. . . . .

......
......
......
......
......
......
......
......
......
......

.......
.......
.......
.......
.......
.......
.......
.......
.......
.......

......
......
......
......
......
......
......
......
......
......

. . . . . . . . . . . . . . . . . . 387
. . . . . . . . . . . . . . . . . . 387
. . . . . . . . . . . . . . . . . . 389
. . . . . . . . . . . . . . . . . . 390
. . . . . . . . . . . . . . . . . . 392
. . . . . . . . . . . . . . . . . . 393
. . . . . . . . . . . . . . . . . . 394
. . . . . . . . . . . . . . . . . . 396
. . . . . . . . . . . . . . . . . . 398
. . . . . . . . . . . . . . . . . . 399

F6TNFP . . . . . . . . . . .
CREATE F6TNFP. . . .
DELETE F6TNFP . . . .
GET F6TNFP . . . . . . .
GETTEST F6TNFP. . .
LOCK F6TNFP . . . . . .
PERFTEST F6TNFP. .
STOPTEST F6TNFP .
UNLOCK F6TNFP . . .

......
......
......
......
......
......
......
......
......

.......
.......
.......
.......
.......
.......
.......
.......
.......

......
......
......
......
......
......
......
......
......

.......
.......
.......
.......
.......
.......
.......
.......
.......

......
......
......
......
......
......
......
......
......

. . . . . 376
. . . . . 376
. . . . . 377
. . . . . 379
. . . . . 380
. . . . . 381
. . . . . 382
. . . . . 384
. . . . . 385

. . . . . 401
. . . . . 401
. . . . . 402
. . . . . 403
. . . . . 405
. . . . . 406
. . . . . 407
. . . . . 409
. . . . . 410

F6VSWRP. . . . . . . . . . . . . . . .
CREATE F6VSWRP . . . . . . . .
DELETE F6VSWRP . . . . . . . .
GET F6VSWRP . . . . . . . . . . .
GETTEST F6VSWRP . . . . . . .
LOCK F6VSWRP . . . . . . . . . .
PERFTEST F6VSWRP . . . . . .
SET F6VSWRP. . . . . . . . . . . .
STOPTEST F6VSWRP. . . . . .
UNLOCK F6VSWRP. . . . . . . .

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 412
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 412
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 413
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 415
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 416
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 417
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 418
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 419
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 420
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 422

FANP . . . . . . . . . . . . .
CREATE FANP . . . . . .
DELETE FANP . . . . . .
GET FANP . . . . . . . . .
GETTEST FANP. . . . .
LOCK FANP . . . . . . . .

.......
.......
.......
.......
.......
.......

Id:0900d80580627b1d

......
......
......
......
......
......

......
......
......
......
......
......

.......
.......
.......
.......
.......
.......

......
......
......
......
......
......

. . . . . 424
. . . . . 424
. . . . . 426
. . . . . 427
. . . . . 429
. . . . . 430

A50016-G5100-B333-04-7619

BS-4x / 82 II / 240 / 241 / 240XL commands

PERFTEST FANP . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 432


STOPTEST FANP . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 436
UNLOCK FANP . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 437
FCUMAIN . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
CREATE FCUMAIN . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
DELETE FCUMAIN . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
GET FCUMAIN . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
GET FCUMAIN FWID . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
GET FCUMAIN WIRING . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
GETTEST FCUMAIN . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
LOCK FCUMAIN . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
PERFTEST FCUMAIN. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
SET FCUMAIN. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
STOPTEST FCUMAIN. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
UNLOCK FCUMAIN. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

439
439
441
443
444
445
446
448
450
454
455
456

FCUTR. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
CREATE FCUTR . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
DELETE FCUTR . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
GET FCUTR . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
GETTEST FCUTR . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
LOCK FCUTR . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
PERFTEST FCUTR . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
SET FCUTR. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
STOPTEST FCUTR. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
UNLOCK FCUTR. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

458
458
460
461
463
464
466
470
471
472

FTNFP . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
CREATE FTNFP . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
DELETE FTNFP . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
GET FTNFP . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
GETTEST FTNFP . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
LOCK FTNFP . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
PERFTEST FTNFP . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
STOPTEST FTNFP . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
UNLOCK FTNFP . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

474
474
476
477
479
480
482
486
487

FVSWRP . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
CREATE FVSWRP . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
DELETE FVSWRP. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
GET FVSWRP . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
GETTEST FVSWRP . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
LOCK FVSWRP. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
PERFTEST FVSWRP . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
STOPTEST FVSWRP . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
UNLOCK FVSWRP . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

489
489
491
492
493
495
497
501
502

LAPDLE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 504
CREATE LAPDLE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 504

A50016-G5100-B333-04-7619

Id:0900d80580627b1d

BS-4x / 82 II / 240 / 241 / 240XL commands

DELETE LAPDLE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 506


GET LAPDLE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 507
RACK . . . . . . . . . . . . .
CREATE RACK . . . . .
DELETE RACK . . . . . .
GET RACK . . . . . . . . .
LOCK RACK . . . . . . . .
SET RACK . . . . . . . . .
UNLOCK RACK . . . . .

......
......
......
......
......
......
......

.......
.......
.......
.......
.......
.......
.......

......
......
......
......
......
......
......

.......
.......
.......
.......
.......
.......
.......

......
......
......
......
......
......
......

. . . . . 509
. . . . . 509
. . . . . 511
. . . . . 512
. . . . . 514
. . . . . 515
. . . . . 516

REMINV . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 519
DNLIDFD REMINV . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 519
UPLLIDF REMINV . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 520
SOFTWARE-MANAGEMENT. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 522
DNLALLEXE SOFTWARE-MANAGEMENT. . . . . . . . . . . . . . . . . . . . . 522
UPLBTSLOG SOFTWARE-MANAGEMENT . . . . . . . . . . . . . . . . . . . . 523
SYNCBTSE. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 526
GET SYNCBTSE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 526
GETTEST SYNCBTSE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 527
LOCK SYNCBTSE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 529
PERFTEST SYNCBTSE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 531
SET SYNCBTSE. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 534
STOPTEST SYNCBTSE. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 536
UNLOCK SYNCBTSE. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 537
TMA . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 539
CREATE TMA . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 539
DELETE TMA . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 541
GET TMA . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 542
GET TMA PRODUCTINFO. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 543
GETTEST TMA . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 545
LOCK TMA . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 547
PERFTEST TMA. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 548
STOPTEST TMA . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 552
UNLOCK TMA . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 553
TRX. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 556
GET TRX . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 556
GETRELATIONSHIP TRX . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 558
XCONNECT . . . . . . . .
CREATE XCONNECT
DELETE XCONNECT.
GET XCONNECT . . . .
LOCK XCONNECT . . .
SET XCONNECT . . . .
UNLOCK XCONNECT
3

10

......
......
......
......
......
......
......

.......
.......
.......
.......
.......
.......
.......

......
......
......
......
......
......
......

.......
.......
.......
.......
.......
.......
.......

......
......
......
......
......
......
......

. . . . . 560
. . . . . 560
. . . . . 562
. . . . . 563
. . . . . 567
. . . . . 569
. . . . . 570

Parameters/attributes in alphabetical order . . . . . . . . . . . . . . . . . . . . . 572

Id:0900d80580627b1d

A50016-G5100-B333-04-7619

BS-4x / 82 II / 240 / 241 / 240XL commands

A50016-G5100-B333-04-7619

a. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
ABISCH . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
ABISLKSAT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
ABISTIME . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
ACBQPFF . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
ACBQPMAX . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
ACEFLFF . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
ACFERMAX . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
ACLNKTYP . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
ACMAXEFLDMA . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
ACMINEFLDMA. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
ACONN . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
ACPER . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
ACTVINC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
ALIGCOBA . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
ALRMCLET . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
ALRMCOUNTER . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
ALRMPERT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
ALRMSEVXXX . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
ALRMT1/2/3. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
ALS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
AMRLKAT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
AMRLKATWFS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
ANT<x>CELLNO . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
ANT<x>SCNRX . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
ANT<x>WDRX. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
ANT<x>WDTX . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
ANTB . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
ANTHOPHW . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
ANTHOPMOD . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
ANTHOPP . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
ANTHOPST . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
ANTMN . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
ANTSN. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
ARFACCHACMDF. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
ASCICIPH . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
ASEV . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
AST . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
ASTRING . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
ASUBLKSAT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
AVS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

573
573
573
573
574
575
575
575
576
576
577
577
578
578
579
579
579
580
581
581
582
583
584
584
585
586
589
590
591
591
592
592
592
593
593
594
594
595
595
596
596

b. . . . . . . . . . . . . . .
BATTCAP . . . . . . .
BCCHFREQ. . . . . .
BCOMTYPE. . . . . .
BCPBL . . . . . . . . . .
BERT . . . . . . . . . . .

598
598
598
599
600
600

......
......
......
......
......
......

.......
.......
.......
.......
.......
.......

Id:0900d80580627b1d

......
......
......
......
......
......

.......
.......
.......
.......
.......
.......

......
......
......
......
......
......

.......
.......
.......
.......
.......
.......

11

BS-4x / 82 II / 240 / 241 / 240XL commands

BMWD<x>. . . .
BND<x> . . . . .
BSIC . . . . . . . .
BSWVER . . . .
BTSID . . . . . . .
BTSISHOP . . .
BURNOFFS . .

......
......
......
......
......
......
......

......
......
......
......
......
......
......

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 601
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 601
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 602
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 602
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 603
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 603
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 604

c . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 605
CCPBL . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 605
CELLNO . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 605
CELLTYPE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 606
CHIDT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 606
CHTYPE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 607
CLKACC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 609
COMBMD . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 609
CUCONF. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 610
CUWIRING . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 610
d .................
DESTDIR . . . . . . . . . .
DLTESTFREQ . . . . . .
DMACFHSYID . . . . . .
DMCFWID. . . . . . . . . .
DTMHOMTIMER. . . . .
DYNTRACGRAN . . . .

......
......
......
......
......
......
......

.......
.......
.......
.......
.......
.......
.......

. . . . . . . . . . . . . . . . . . . . . . . . 612
. . . . . . . . . . . . . . . . . . . . . . . . 612
. . . . . . . . . . . . . . . . . . . . . . . . 612
. . . . . . . . . . . . . . . . . . . . . . . . 612
. . . . . . . . . . . . . . . . . . . . . . . . 613
. . . . . . . . . . . . . . . . . . . . . . . . 613
. . . . . . . . . . . . . . . . . . . . . . . . 613

e . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 615
EAC. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 615
EANTHOP. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 615
EAUTONEG . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 615
EAUTOREC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 616
EEOTD . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 616
EEXCDIST . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 617
EFCUSUP. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 617
EFLWCTRL. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 618
EINTSITSYN. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 619
EMT1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 619
EMT2 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 620
ENTRIES . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 620
EQUPOS. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 620
ERFACCHALPDMF . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 621
ERFACCHCMDF . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 623
ERSACCHDL . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 625
ERSACCHUL . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 630
ETOP . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 635
ETXDIVTS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 637
EVTYP . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 637
EXCDIST . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 638

12

Id:0900d80580627b1d

A50016-G5100-B333-04-7619

BS-4x / 82 II / 240 / 241 / 240XL commands

EXTMODE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 638
f ......................................................
F6FWID . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
FACCHQ . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
FACHBT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
FBAND. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
FCUMAINWIRING . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
FCUMODE. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
FILE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
FILEFWV . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
FILEID . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
FILESWV . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
FILETYPE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
FPGAFWVER . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
FRANOFFS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
FWVER . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

640
640
640
640
641
641
642
643
643
644
645
646
646
647
647

g. . . . . . . . . . . . . . .
GN<x> . . . . . . . . . .
GNA . . . . . . . . . . . .
GNADB . . . . . . . . .
GNR . . . . . . . . . . . .
GSMTIME . . . . . . .
GTWADRV4 . . . . .

648
648
648
649
650
650
651

......
......
......
......
......
......
......

.......
.......
.......
.......
.......
.......
.......

......
......
......
......
......
......
......

.......
.......
.......
.......
.......
.......
.......

......
......
......
......
......
......
......

.......
.......
.......
.......
.......
.......
.......

h . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 652
HOPMODE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 652
HSN . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 652

A50016-G5100-B333-04-7619

i ......................................................
INSD . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
INSID . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
INTAVEPAR . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
INTCLASS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
INTINF . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
INTLVBND . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
IPADR . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

653
653
653
653
654
654
654
655

l ......................................................
L1CTRLTS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
L1PT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
L1RAT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
LAPDCH . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
LAPDOVLT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
LAPDOVLTH . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
LAPDOVLTRXL . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
LCONF. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
LIMP . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
LMTLSESS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

656
656
656
657
657
658
659
660
660
661
662

Id:0900d80580627b1d

13

BS-4x / 82 II / 240 / 241 / 240XL commands

LMTLTIME . . .
LMTUAL . . . . .
LMTUNAME . .
LNAMDB . . . . .
LNAMODE . . .
LNAPRED . . . .
LOCALADDR .
LOCLUDP . . . .
LOCNAME . . .
LOSPKTTH . . .
LPDLMSAT . . .
LRU. . . . . . . . .
LSIND . . . . . . .

......
......
......
......
......
......
......
......
......
......
......
......
......

......
......
......
......
......
......
......
......
......
......
......
......
......

.......
.......
.......
.......
.......
.......
.......
.......
.......
.......
.......
.......
.......

......
......
......
......
......
......
......
......
......
......
......
......
......

.......
.......
.......
.......
.......
.......
.......
.......
.......
.......
.......
.......
.......

......
......
......
......
......
......
......
......
......
......
......
......
......

. . . . . 662
. . . . . 662
. . . . . 663
. . . . . 663
. . . . . 664
. . . . . 664
. . . . . 667
. . . . . 667
. . . . . 667
. . . . . 668
. . . . . 668
. . . . . 669
. . . . . 669

m . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 672
MACADDR . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 672
MAIO. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 672
MAXGN . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 672
MAXPDV. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 673
MINGN . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 673
MOBALLOC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 673
MOEC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 675
MONPRT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 675
MORT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 676
MPHERR . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 677
MPTSLXX . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 678
MRSYNCT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 679
MSTXPMAX . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 679
MSTXPMAXC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 680
MTLT. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 681
MTYP . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 681
n ...........
NEPTTREP. . .
NTWTYPC . . .
NTWTYPE . . .
NY1 . . . . . . . . .
NY2 . . . . . . . . .

......
......
......
......
......
......

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 683
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 683
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 683
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 683
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 685
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 685

o ...........
OMLAPDRT . .
OST. . . . . . . . .
OUTPUTPR . .
OVERWRITE .
OVPTINS . . . .

......
......
......
......
......
......

......
......
......
......
......
......

.......
.......
.......
.......
.......
.......

......
......
......
......
......
......

.......
.......
.......
.......
.......
.......

......
......
......
......
......
......

. . . . . 686
. . . . . 686
. . . . . 686
. . . . . 687
. . . . . 687
. . . . . 687

p . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 689
PCCCHLDI . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 689
PEERADDR . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 689

14

Id:0900d80580627b1d

A50016-G5100-B333-04-7619

BS-4x / 82 II / 240 / 241 / 240XL commands

A50016-G5100-B333-04-7619

PEERUDPPORT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
PKTLAT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
PNGF . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
PNGPKT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
PNOFACCH. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
PRDINF . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
PRDIRECT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
PRS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
PSTAT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
PUSG. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
PWNAME. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
PWROUT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
PWRRED . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

689
690
690
691
691
691
692
692
693
693
694
694
695

r......................................................
RACHBT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
RACHLAS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
RADIOMG . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
RADIOMR . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
RELEQUIPOBJ . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
RELFUNCOBJ . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
REPTYP . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
RFRSINDP . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
RSACCHRXLDL . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
RSACCHRXLUL . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
RSACCHTODL . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
RSACCHTOUL . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
RXBMAXF . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
RXBMINF. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
RXDIVSV . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
RXLEVADJ . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
RXLEVADJN1D1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
RXSIGLEVADJ . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
RXSIGLEVADJC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
RXSWCURSET . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

696
696
696
696
697
697
698
700
701
701
701
702
702
702
703
703
704
704
704
705
705

s. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
SALUNAME . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
SBPRT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
SBSCSLCV . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
SCELLNO . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
SCID . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
SCLPRIOLST . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
SFPSERID . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
SHLAPDIT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
SLOTNO . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
SRCDIR . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
SRCPATH . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

706
706
706
706
707
708
708
710
710
711
711
712

Id:0900d80580627b1d

15

BS-4x / 82 II / 240 / 241 / 240XL commands

STATIME . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 712
STDBYST . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 712
SUBUNT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 713
SWBCAPABILITY . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 713
SWBSERVSTATE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 714
SWLCFID . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 714
SWLCVER . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 715
SWLDINT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 716
SWLDSAF. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 716
SWLDST . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 717
SYNCSRC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 718
SYNCSTAT. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 718
SYSID . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 719
t . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 720
T200 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 720
T3105 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 720
T3115 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 721
T3151 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 721
TAADJ. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 721
TCC. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 722
TCCCHLDI . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 722
TDMAP . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 723
TEI . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 724
TESTMODE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 724
TESTMON . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 725
TESTNO . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 730
TESTOUT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 730
TESTPWRRED . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 731
TESTST . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 731
TIMEDELAY . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 731
TNCH . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 732
TNFTARGF. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 732
TRXAREA . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 733
TRXCPBL . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 733
TRXFREQ . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 734
TRXMD . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 735
TSC. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 735
TSLPOOL . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 736
TSYNC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 737
TSYNCD . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 737
TSYNCR . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 738
TSYNCU . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 738
TTRAU . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 739
TUPLREP . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 739
TXBMAXF . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 739
TXBMINF . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 740
TXDIVTSEXCPT. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 740

16

Id:0900d80580627b1d

A50016-G5100-B333-04-7619

BS-4x / 82 II / 240 / 241 / 240XL commands

TXDIVTSPAR . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
TXLEVADJ. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
TXSIGLEVADJ . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
TXSIGLEVADJC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
TYPOFETH . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
TYPRACK . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

741
741
742
742
742
743

v. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
VENDNA . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
VGSCULFT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
VLANID . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
VSWRTDB . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

745
745
745
746
747

w .....................................................
WDDUVSWR . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
WDFTNFP . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
WDLNA . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

748
748
750
752

Nack causes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 756

Appendix: values for ERFACCHALPDMF, ERFACCHCMDF, ERSACCHDL, ERSACCHUL and ETOP . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 760

A50016-G5100-B333-04-7619

Id:0900d80580627b1d

17

BS-4x / 82 II / 240 / 241 / 240XL commands

List of Figures
Figure 1
Figure 2
Figure 3
Figure 4
Figure 5
Figure 6
Figure 7
Figure 8
Figure 9

18

BTSEP BR10.0 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22
BTSEP BR10.0: tree view . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29
BTSEP BR10.0: graphic view . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30
BTSEP BR10.0 tree view with list of command . . . . . . . . . . . . . . . . . . . 31
BTSP BR10.0: CREATE ... ACDCP command (example) . . . . . . . . . . . 32
BTSP BR10.0: SET ... COBA command (example) . . . . . . . . . . . . . . . . 32
Command viewer window: CREATE ... BPORT command (example) . . 33
Command viewer window: SET ... COBA command (example) . . . . . . . 33
BS240, BS241, BS240XL, BS40, BS41, BS40II and BS82II main tree . 34

Id:0900d80580627b1d

A50016-G5100-B333-04-7619

BS-4x / 82 II / 240 / 241 / 240XL commands

Reason for update

Reason for update


Issue history
Issue

Date

Summary

01

07/2008

New release BR10.0

02

11/2008

New commands and attributes have been added and modified

03

03/2009

New commands and attributes have been added and modified

04

10/2009

The description of ALRMT1/T2/T3 attributes related to COBA


object has been updated. Default values have been updated too.

Issue 04 for release BR10.0


Chapter/Section
2. Objects and commands in
alphabetical order

Summary
BCOM: CREATE
BTSEP: GETACTIVEALARMS
BTSM: ACTIVATE
COBA: SET
F6DCTMA: CREATE, DELETE, GET, GETTEST,
LOCK, PERFTEST, STOPTEST, UNLOCK.
F6LNA: CREATE, DELETE, GET, GETTEST,
LOCK, PERFTEST, STOPTEST, SET, UNLOCK.
F6TNFP: CREATE, DELETE, GET, GETTEST,
LOCK, PERFTEST, STOPTEST, SET, UNLOCK.
F6VSWRP: CREATE, DELETE, GET, GETTEST,
LOCK, PERFTEST, STOPTEST, SET, UNLOCK.
SOFTWARE-MANAGEMENT: DNLALLEXE
SOFTWARE-MANAGEMENT
For MOC mentioned above the System
Responses, Application Guidelines and Example
section have been updated

3 Parameters/attributes in alpha- Modified attributes: ALRMSEVXXX, BCPBL,


betical order
GTWADRV4, LAPDCH, MORT

A50016-G5100-B333-04-7619

Id:0900d8058064b2a7

19

Reason for update

20

BS-4x / 82 II / 240 / 241 / 240XL commands

Id:0900d8058064b2a7

A50016-G5100-B333-04-7619

BS-4x / 82 II / 240 / 241 / 240XL commands

Introduction

1 Introduction
1.1

General
This manual describes the commands for the BTSE, necessary to manage the
BS4x/240/241/240XL/BS40II/BS82II (BTSplus Mainline) network elements. Each time
the term BTSplus Mainline is used, the term is referred to the
BS4x/240/241/240XL/BS40II/BS82II.
The way to submit any command to manage the BTSplus Mainline system is represented by LMT Evolution Tool.
The LMT Evolution, that is the interface between the user and the NE, can manage different families of possibly connected network element. For instance, the LMT Evolution
is able to recognize and then to visualize the command trees related to the following
BTS equipments:
BS20, BS21, BS22, BS60, BS61
BS40, BS41, BS40II
BS240, BS241, BS240XL
BS82
BS82II
BS240XS
BS288
The LMT Evolution for Base Station is the application commonly used to configure and
maintain the GSM network through a set of functions and procedures tailored to operate
in a local context. Refer to Operating guidelines: LMT Evolution for more details about
LMT Evolution main functionality.
Local context means that the LMT Evolution is physically connected to the Network
Element through an interface based on proprietary protocols (HALCA and DLHC).
(Refer to Figure 1).
Anyway, out of the local context, LMT Evolution does not have an overall control on the
GSM network and, consequently, available functions are limited to those allowed by
local constraints.
The purpose of LMT is to make Operation and Maintenance easy and to provide all information about the state of an NE.

g Position of COBAs and COSAs. COBA/COSA 0 will be found always on the left side
of the rack and COBA/COSA 1 on the right side of the rack.

A50016-G5100-B333-04-7619

Id:0900d80580598372

21

Introduction

BS-4x / 82 II / 240 / 241 / 240XL commands

Figure 1

1.1.1

BTSEP BR10.0

Structure of the manual


The manual is divided into five main parts:
1. Section 1 provides general information about command structure and LMT Evolution operations
2. Section 2 describes objects and commands, listed in alphabetical order
3. Section 3 describes the parameters of the commands, listed in alphabetical order.
Additionally there is the information in which commands the parameter is used
4. Section 4 lists the NACK causes
5. Section 5 is an appendix. It lists the values for some main parameters
There is the possibility to jump by clicking on the selected item (reference to the parameter description or to the GUI representation in chapter 2; reference to the commands in
chapter 3) to the requested information.
In the command representation (chapter 2) the parameters/attributes in brackets are
optional parameters.

22

Id:0900d80580598372

A50016-G5100-B333-04-7619

BS-4x / 82 II / 240 / 241 / 240XL commands

1.1.2

Introduction

Structure of the commands


Both generic commands which can be obtained through selections from the LMT tree
and commands which are created by the operator using the CLI interface must use the
following syntax:
1. Action object [object]:NAME=object:n[/object:n],attribute=value[-value] [,attribute=value];
2. Action object :NAME=object:n[/object:n],attribute=value[&value] [,attribute=value];
3. Action object [object]:NAME=object:n[/object:n],[REQATTL]=attribute [&attribute];
4. Action object [object]:NAME=object:n[/object:n];

g The syntax rules shown in example 2. are used only for GET commands.
where:
"Action" specifies the command that is being executed and that belongs to a list of functions applicable to the BTSE system (for example: "CREATE", "DELETE", "SET", etc).
object represents the hardware or logical identifier that must be submitted to the
command (for example: "RACK", "CU", "BTSM", etc).
[object] logical identifier that must be submitted to the commands DELETE BTSEP
(for example: "DBFILE") FORMAT BTSEP (for example: "FLASH"), GET BTSEP (for
example: "NOSWL", "SWL") or GET CU (for example: "ESN", "NOESN").
"n" specifies the relative number (for example: ACDCP:n n=0, CU:n n=0..11, etc. See
table below). The LMT Evolution CLI allows * or & instead of a simple number for a
object instance (for example: CU:* (all), CU:0&2&3 (0,2,3) or CU:0&&3 (0,1,2,3).
"attribute" is the acronym of the real attribute of an object (for example: LNAPRED=
Low Noise Amplifier Predecessor of DULNA, etc.).
"value" represent the value of the attribute (or the values of its fields). It is possible to
input a value not just using the default data type (usually decimal) but also to input the
data e.g. as hex value or as binary value.

1.1.3

Ranges for the relative number of the BTSE objects


The ranges shown on the LMT Evolution for the relative numbers of the managed
objects depends on the type of hardware to which the LMT Evolution itself is connected.
The following tables show the ranges allowed for the managed objects of the different
type of BTSE racks (i.e. base, extension, service) relevant to BTSplus Mainline.
BS240 /BS241 BS240SR BS240XL
BS241SR

BS240XLSR BS4x

ACDCP

0..1

0..1

ACT

BATTERY

0..3

0..3

0..1

BCOM

0..1

0..1

BPORT

0..7

0..7

0..7

BTS

0..11

0..11

0..3

BTSEP

BTSM

A50016-G5100-B333-04-7619

Id:0900d80580598372

23

Introduction

BS-4x / 82 II / 240 / 241 / 240XL commands

CHAN

0..7

0..7

0..7

COBA

0..1

0..1

0..1

COSA***)

0..1

0..1

0..1

CU

0..7

0..11

0..3

DIDCTMA

0..3

0..7

0..1

DILNA

0..3

0..7

0..1

DUAMCO

0..3

0..5

0..1

DUDCTMA

0..7

0..11

0..3

DULNA

0..7

0..11

0..3

DUVSWR

0..7

0..11

0..3

ENVABTSE

0..56 *)

0..8

0..56 *) **)

0..8 **)

0..56

ETHCON

F6DCTMA

0..3

0..3

F6LNA

0..3

0..3

F6TNFP

0..11

0..11

F6VSWRP

0..1

0..1

FANP***)

0..5

0..5

0..7

0..7

0..5

FCUMAIN

0..7

0..11

0..3

FCUTR

0..15

0..23

0..7

FTNFP

0..7

0..7

0..3

FVSWRP

0..3

0..3

0..1

LAPDLE

0..10

0..10

0..10

0..10

0..10

LMU

RACK

0..7

4..7

0, 1, 3..7

3..7

0, 4..7

BTSETEST

1..255

1..255

1..255

1..255

1..255

TMA***)

0..11

0..15

0..5

SYNCBTSE

TRX

0..23

0..23

0..3

XCONNECT

0..7

0..7

0..7

g *) ENVABTSE object instances 0..56 exist only for rack 0, for other rack instances
the range is 0..8.

g **) ENVABTSE object instances 0 and 1 are not supported by BS240XL,


BS240XLSR.

g ***) COSA, FANP, TMA: no processor


g The LMU function is no longer supported. Do not use any LMU commands.
ACDCP

24

BS40II

BS82II

Id:0900d80580598372

A50016-G5100-B333-04-7619

BS-4x / 82 II / 240 / 241 / 240XL commands

Introduction

ACT

BATTERY

BCOM

BPORT

0..7

0..3 (note)

BTS

0..3

0..5

BTSEP

BTSM

CHAN

0..7

0..7

COBA

0..1

COSA

0..1

CU

0..3

0..1

DIDCTMA

0..1

DILNA

0..1

DUDCTMA

0..7

0..1

DULNA

0..7

0..1

DUVSWR

0..7

0..1

ENVABTSE

0..56 *)

0..5

ETHCON

F6DCTMA

F6LNA

F6TNFP

F6VSWRP

FANP

0..4

FCUMAIN

0..3

0..1

FCUTR

0..7

0..3

FCUMAIN

0..3

0..1

FCUTR

0..7

0..3

FTNFP

0..7

FVSWRP

0..3

LAPDLE

0..10

0..10 (note)

LMU

RACK

0, 4..7

0..2

BTSETEST

1..255

1..255

TMA

0..7

0..3

SYNCBTSE

TRX

0..3

0..5

A50016-G5100-B333-04-7619

Id:0900d80580598372

25

Introduction

BS-4x / 82 II / 240 / 241 / 240XL commands

XCONNECT

0..7

0..3 (note)

g *) ENVABTSE object instances 0..56 exist only for rack 0, for other rack instances
the range is 0..8.

g BS82II BPORT object: range 0..3 is supported only if COBA4P12 is installed, in all
other cases the range is 0..1.

g BS82II LAPDLE object: in case of COBA4P12 the BTSE will reject the creation of
object instances 5..10.

g BS82II XCONNECT object: instances #2 and #3 are supported only if COBA4P12


is installed, in all other cases only instances 0 and 1 are allowed.

g BS40/41 with its low number of carrier units shall be excluded from switched beam
solution.

g The LMU function is no longer supported. Do not use any LMU commands.
1.1.4

Command layout
The first information given for each command is the phase, or phases, within which the
command can be entered. Then, subsequent selections are shown which are required
to get the command starting from the LMT Evolution Tree.
The command is specified with its syntax and it is followed by the individual fields used
to explain the functions of the command itself.
Command Tree:
The command tree shows the way to get the command and a hint to a GUI example in
chapter 1.
Applicability:
This field shows the working phases and the user profile which allow the execution of
the command. The user profile visibility level is associated with a user identification
"user_id" and password. Four user profiles visibility level are provided:
0

ReadOnly

Command Access

ReadWrite

Super User

Each profile gives the user different access levels to the system features and the higher
is the level the higher is the number of operations which can be performed.

g For User_id and Password contact your local service organization.


Command Description:
This field explains the function of the command transmitted by the LMT Evolution to the
BTSE (when and why it is used, for which operation task).
Long Names:

26

Id:0900d80580598372

A50016-G5100-B333-04-7619

BS-4x / 82 II / 240 / 241 / 240XL commands

Introduction

This part shows (for an overview) the abbreviations of the parameters/attributes used in
the command and its corresponding long names.
System Responses:
They are response messages sent as acknowledgment for completion of input
commands or they contain information requested by the user. The typical structure of
the response messages contains: the date and time, the command line, the system
response. The response messages can be either normal (successful) or error messages. In such a case they contain the reason for the failure.
Short system messages such as: indication of system loading/downloading functions in
progress, are also reported as information to the LMT Evolution.
Application Guidelines:
These are warnings given when using this command or information related to the environment in which the command is submitted.
Example of Command Execution:
This is an example on how to enter the command with its parameters and their relevant
values.

A50016-G5100-B333-04-7619

Id:0900d80580598372

27

Introduction

BS-4x / 82 II / 240 / 241 / 240XL commands

1.2

Graphical user interface (GUI) representation of the LMT


Evolution
g Reference figures: the reported figures are only for reference and could be not
aligned to the last version of LMT Evolution product.

1.2.1

Start LMT Evolution window


LMT Evolution is the graphical user interface which performs the command interaction
with the Network Element. This enables the user to navigate the object containment
Tree View (see Figure 2) or Graphic View (see Figure 3) of the NE and to select a
specific command from a list of available ones.
From the graphical point of view, the LMT Evolution Main window provides an access
point to all the LMT Evolution functionality and represents an overall monitoring mode
as regards the connection status information.
According to its dynamic and "adaptive" properties, the LMT Evolution Main window is
displayed taking into account the connection and operating parameters that may affect
the visualization of the resulting window functionality.
The main parameters that influence the visualization of LMT Evolution Main Window
are:
Working Context: indicates a mode in which the user is currently working with the
LMT Evolution
Network Element configuration: family, type, phase, version, etc.
By using the LMT Evolution the user can:
Acquire commands, action or scripts
Send and receive messages containing commands or responses to/from the
network element
Have script/commands translation services
Store issued commands and retrieve responses coming from the NE

28

Id:0900d80580598372

A50016-G5100-B333-04-7619

BS-4x / 82 II / 240 / 241 / 240XL commands

Figure 2

A50016-G5100-B333-04-7619

Introduction

BTSEP BR10.0: tree view

Id:0900d80580598372

29

Introduction

BS-4x / 82 II / 240 / 241 / 240XL commands

Figure 3

30

BTSEP BR10.0: graphic view

Id:0900d80580598372

A50016-G5100-B333-04-7619

BS-4x / 82 II / 240 / 241 / 240XL commands

1.2.2

Introduction

LMT Evolution windows for GET, CREATE, SET, ..., commands


The LMT Evolution is mainly used to build CREATE, SET, GET, LOCK, UNLOCK, etc.
commands to be sent to the Network Element. Starting from the containment Tree View
or Graphic View,you can perform the following operations:
Select the functional/equipment/software management object
Select a command from the list of commands displayed by the pop up list box (see
Figure 4)

Figure 4

BTSEP BR10.0 tree view with list of command

The presence of ellipses (see SET ... COBA Command) following the name of the
command indicates that the command could require a further configuration of the attributes before being submitted. In this case the Command Viewer window is opened and
the user can fill in the attribute cells as desired.
If no ellipses are present (see GET COBA Command), the command does not need any
further configuration and it is submitted to the network element without opening the
Command Viewer window.
In case of the presence of ellipses (see CREATE ... BPORT Command in Figure 5 or
SET ... COBA Command in Figure 6) the Command Viewer panel is displayed (see
Figure 7 and Figure 8). The user has to perform the following operations:
Select one or more parameters and choose the appropriate values, the command is
executed after clicking on the Submit button
If, during the translation phase, an error is found in the command string, the
command is not sent to the N.E. In this case reenter the command following the
instructions provided by the diagnostic message shown in the right middle pane.

A50016-G5100-B333-04-7619

Id:0900d80580598372

31

Introduction

32

BS-4x / 82 II / 240 / 241 / 240XL commands

Figure 5

BTSP BR10.0: CREATE ... ACDCP command (example)

Figure 6

BTSP BR10.0: SET ... COBA command (example)

Id:0900d80580598372

A50016-G5100-B333-04-7619

BS-4x / 82 II / 240 / 241 / 240XL commands

Introduction

Figure 7

Command viewer window: CREATE ... BPORT command (example)

Figure 8

Command viewer window: SET ... COBA command (example)

For all procedures of module replacement the actions to be performed are similar. As
first action, the module must be locked, replaced, tested and finally unlocked. Some
modules have to be replaced without locking and for some others, the BTSEP has to be
switched from phase 3 to 2.

A50016-G5100-B333-04-7619

Id:0900d80580598372

33

Introduction

BS-4x / 82 II / 240 / 241 / 240XL commands

1.3
1.3.1

Command tree
BS240, BS241, BS240XL, BS40, BS41, BS40II and BS82II main tree
MANAGED ELEMENT
BSS-EQUIPMENT
BTSEP

BPORT
CESPW
CESTUNNEL
COBAETHINTF
ETHPORT
LAPDLE
SYNCBTSE
XCONNECT
RACK
BTSETEST
REMINV

ACDCP
ACT
BATTERY
BCOM
COBA
COSA

BSS-FUNCTIONAL
BTSM

CU
DIDCTMA
DILNA

BTS
TRX
CHAN

DUDCTMA
DULNA
DUVSWR
ENVABTSE
FANP

SOFTWARE-MANAGEMENT

FCUMAIN
FCUTR
FTNFP
FVSWRP
F6DTMA
F6LNA
F6TNFP
F6VSWRP
LMU
TMA
ETHCON
DUAMCO

Figure 9

34

BS240, BS241, BS240XL, BS40, BS41, BS40II and BS82II main tree

Id:0900d80580598372

A50016-G5100-B333-04-7619

BS-4x / 82 II / 240 / 241 / 240XL commands

1.3.2
Managed Element

Introduction

Alphabetical list of commands


Phase1

Phase2

Phase3

CREATE ACDCP

CREATE ACDCP

DELETE ACDCP

DELETE ACDCP

GET ACDCP

GET ACDCP

GETTEST ACDCP

GETTEST ACDCP

LOCK ACDCP

LOCK ACDCP

PERFTEST ACDCP

PERFTEST ACDCP

STOPTEST ACDCP

STOPTEST ACDCP

UNLOCK ACDCP

UNLOCK ACDCP

Phase2

Phase3

CREATE ACT

CREATE ACT

DELETE ACT

DELETE ACT

GET ACT

GET ACT

GETTEST ACT

GETTEST ACT

LOCK ACT

LOCK ACT

PERFTEST ACT

PERFTEST ACT

STOPTEST ACT

STOPTEST ACT

UNLOCK ACT

UNLOCK ACT

Phase2

Phase3

CREATE BATTERY

CREATE BATTERY

DELETE BATTERY

DELETE BATTERY

GET BATTERY

GET BATTERY

GETTEST BATTERY

GETTEST BATTERY

LOCK BATTERY

LOCK BATTERY

PERFTEST BATTERY

PERFTEST BATTERY

STOPTEST BATTERY

STOPTEST BATTERY

UNLOCK BATTERY

UNLOCK BATTERY

Phase2

Phase3

ACDCP

Managed Element

Phase1

ACT

Managed Element

Phase1

BATTERY

Managed Element

Phase1

A50016-G5100-B333-04-7619

Id:0900d80580598372

35

Introduction

BS-4x / 82 II / 240 / 241 / 240XL commands

BCOM

Managed Element

Phase1

CREATE BCOM

CREATE BCOM

DELETE BCOM

DELETE BCOM

GET BCOM

GET BCOM

GETWIRINGRX BCOM

GETWIRINGRX BCOM

GETWIRINGTX BCOM

GETWIRINGTX BCOM

GETRELATIONSHIP
BCOM

GETRELATIONSHIP
BCOM

GETTEST BCOM

GETTEST BCOM

LOCK BCOM

LOCK BCOM

PERFTEST BCOM

PERFTEST BCOM

SET BCOM

SET BCOM

SETWIRINGRX BCOM

SETWIRINGRX BCOM

SETWIRINGTX BCOM

SETWIRINGTX BCOM

STOPTEST BCOM

STOPTEST BCOM

UNLOCK BCOM

UNLOCK BCOM

Phase2

Phase3

CREATE BPORT

CREATE BPORT

DELETE BPORT

DELETE BPORT

GET BPORT

GET BPORT

LOCK BPORT

LOCK BPORT

SET BPORT

SET BPORT

UNLOCK BPORT

UNLOCK BPORT

Phase2

Phase3

BPORT

Managed Element

Phase1

BTS
GET BTS
GET BTS TIMER

Managed Element

Phase1

Phase2

Phase3

BTSEP
DELETE BTSEP DBFILE
FORMAT BTSEP FLASH

FORMAT BTSEP FLASH


GET BTSEP NOSWL

36

Id:0900d80580598372

GET BTSEP NOSWL

A50016-G5100-B333-04-7619

BS-4x / 82 II / 240 / 241 / 240XL commands

Managed Element

Introduction

GET BTSEP SWL

GET BTSEP SWL

GETACTIVEALARMS
BTSEP

GETACTIVEALARMS
BTSEP

PERFTEST BTSEP

PERFTEST BTSEP

PING BTSEP

PING BTSEP

SET BTSEP

SET BTSEP

STOPTEST BTSEP

STOPTEST BTSEP

Phase2

Phase3

GET BTSETEST

GET BTSETEST

Phase1

Phase2

Phase3

ACTIVATE BTSM

ACTIVATE BTSM

Phase1

BTSETEST

Managed Element
BTSM

ACTIVATE_DELAYED
BTSM
CONNBSC BTSM
DISCBSC BTSM
FWUPGRADE BTSM

FWUPGRADE BTSM

GET BTSM NOSWL

GET BTSM NOSWL

GET BTSM OVERLOAD

GET BTSM OVERLOAD

GET BTSM SWL

GET BTSM SWL


LOCKREQUEST BTSM

SET BTSM
SHUTDOWN BTSM
UNLOCKREQUEST
BTSM

Managed Element

Phase1

Phase2

Phase3

CREATE CESPW

CREATE CESPW

DELETE CESPW

DELETE CESPW

GET CESPW

GET CESPW

LOCK CESPW

LOCK CESPW

SET CESPW

SET CESPW

CESPW

A50016-G5100-B333-04-7619

Id:0900d80580598372

37

Introduction

Managed Element

BS-4x / 82 II / 240 / 241 / 240XL commands

Phase1

UNLOCK CESPW

UNLOCK CESPW

Phase2

Phase3

CESTUNNEL
CREATE CESTUNNEL
DELETE CESTUNNEL
GET CESTUNNEL

GET CESTUNNEL

LOCK CESTUNNEL
SET CESTUNNEL

SET CESTUNNEL

UNLOCK CESTUNNEL

Managed Element

Phase1

Phase2

Phase3

CHAN
GET CHAN

Managed Element

Phase1

Phase2

Phase3

CREATE COBA

CREATE COBA

DELETE COBA

DELETE COBA

GET COBA

GET COBA

GETRELATIONSHIP
COBA

GETRELATIONSHIP
COBA

GETTEST COBA

GETTEST COBA

LOCK COBA

LOCK COBA

PERFTEST COBA

PERFTEST COBA

SET COBA

SET COBA

STOPTEST COBA

STOPTEST COBA

SWITCH COBA

SWITCH COBA

UNLOCK COBA

UNLOCK COBA

Phase2

Phase3

GET COBAETHINTF

GET COBAETHINTF

COBA

Managed Element

Phase1

COBAETHINTF

LOCK COBAETHINTF
SET COBAETHINTF

38

Id:0900d80580598372

A50016-G5100-B333-04-7619

BS-4x / 82 II / 240 / 241 / 240XL commands

Introduction

UNLOCK COBAETHINTF

Managed Element

Phase1

Phase2

Phase3

CREATE COSA

CREATE COSA

DELETE COSA

DELETE COSA

GET COSA

GET COSA

GETTEST COSA

GETTEST COSA

LOCK COSA

LOCK COSA

PERFTEST COSA

PERFTEST COSA

STOPTEST COSA

STOPTEST COSA

UNLOCK COSA

UNLOCK COSA

Phase2

Phase3

CREATE CU

CREATE CU

DELETE CU

DELETE CU

GET CU

GET CU

GET CU FWID

GET CU FWID

GET CU WIRING

GET CU WIRING

GETTEST CU

GETTEST CU

LOCK CU

LOCK CU

PERFTEST CU

PERFTEST CU

SET CU

SET CU

STOPTEST CU

STOPTEST CU

UNLOCK CU

UNLOCK CU

Phase2

Phase3

CREATE DIDCTMA

CREATE DIDCTMA

DELETE DIDCTMA

DELETE DIDCTMA

GET DIDCTMA

GET DIDCTMA

GETTEST DIDCTMA

GETTEST DIDCTMA

LOCK DIDCTMA

LOCK DIDCTMA

PERFTEST DIDCTMA

PERFTEST DIDCTMA

COSA

Managed Element

Phase1

CU

Managed Element

Phase1

DIDCTMA

A50016-G5100-B333-04-7619

Id:0900d80580598372

39

Introduction

Managed Element

BS-4x / 82 II / 240 / 241 / 240XL commands

Phase1

STOPTEST DIDCTMA

STOPTEST DIDCTMA

UNLOCK DIDCTMA

UNLOCK DIDCTMA

Phase2

Phase3

CREATE DILNA

CREATE DILNA

DELETE DILNA

DELETE DILNA

GET DILNA

GET DILNA

GETTEST DILNA

GETTEST DILNA

LOCK DILNA

LOCK DILNA

PERFTEST DILNA

PERFTEST DILNA

SET DILNA

SET DILNA

STOPTEST DILNA

STOPTEST DILNA

UNLOCK DILNA

UNLOCK DILNA

Phase2

Phase3

DELETE DUAMCO

DELETE DUAMCO

GET DUAMCO

GET DUAMCO

GETTEST DUAMCO

GETTEST DUAMCO

LOCK DUAMCO

LOCK DUAMCO

PERFTEST DUAMCO

PERFTEST DUAMCO

STOPTEST DUAMCO

STOPTEST DUAMCO

UNLOCK DUAMCO

UNLOCK DUAMCO

Phase2

Phase3

CREATE DUDCTMA

CREATE DUDCTMA

DELETE DUDCTMA

DELETE DUDCTMA

GET DUDCTMA

GET DUDCTMA

GETTEST DUDCTMA

GETTEST DUDCTMA

LOCK DUDCTMA

LOCK DUDCTMA

PERFTEST DUDCTMA

PERFTEST DUDCTMA

STOPTEST DUDCTMA

STOPTEST DUDCTMA

UNLOCK DUDCTMA

UNLOCK DUDCTMA

DILNA

Managed Element

Phase1

DUAMCO

Managed Element

Phase1

DUDCTMA

40

Id:0900d80580598372

A50016-G5100-B333-04-7619

BS-4x / 82 II / 240 / 241 / 240XL commands

Managed Element

Phase1

Introduction

Phase2

Phase3

CREATE DULNA

CREATE DULNA

DELETE DULNA

DELETE DULNA

GET DULNA

GET DULNA

GETTEST DULNA

GETTEST DULNA

LOCK DULNA

LOCK DULNA

PERFTEST DULNA

PERFTEST DULNA

SET DULNA

SET DULNA

STOPTEST DULNA

STOPTEST DULNA

UNLOCK DULNA

UNLOCK DULNA

Phase2

Phase3

CREATE DUVSWR

CREATE DUVSWR

DELETE DUVSWR

DELETE DUVSWR

GET DUVSWR

GET DUVSWR

GETTEST DUVSWR

GETTEST DUVSWR

LOCK DUVSWR

LOCK DUVSWR

PERFTEST DUVSWR

PERFTEST DUVSWR

SET DUVSWR

SET DUVSWR

STOPTEST DUVSWR

STOPTEST DUVSWR

UNLOCK DUVSWR

UNLOCK DUVSWR

Phase2

Phase3

CREATE ENVABTSE

CREATE ENVABTSE

DELETE ENVABTSE

DELETE ENVABTSE

GET ENVABTSE

GET ENVABTSE

LOCK ENVABTSE

LOCK ENVABTSE

SET ENVABTSE

SET ENVABTSE

UNLOCK ENVABTSE

UNLOCK ENVABTSE

Phase2

Phase3

DULNA

Managed Element

Phase1

DUVSWR

Managed Element

Phase1

ENVABTSE

Managed Element

Phase1

ETHCON

A50016-G5100-B333-04-7619

Id:0900d80580598372

41

Introduction

BS-4x / 82 II / 240 / 241 / 240XL commands

CREATE ETHCON
DELETE ETHCON
GET ETHCON

GET ETHCON

LOCK ETHCON
SET ETHCON

SET ETHCON

UNLOCK ETHCON

Managed Element

Phase1

Phase2

Phase3

CREATE ETHPORT

CREATE ETHPORT

DELETE ETHPORT

DELETE ETHPORT

GET ETHPORT

GET ETHPORT

LOCK ETHPORT

LOCK ETHPORT

SET ETHPORT

SET ETHPORT

UNLOCK ETHPORT

UNLOCK ETHPORT

Phase2

Phase3

CREATE F6DCTMA

CREATE F6DCTMA

DELETE F6DCTMA

DELETE F6DCTMA

GET F6DCTMA

GET F6DCTMA

GETTEST F6DCTMA

GETTEST F6DCTMA

LOCK F6DCTMA

LOCK F6DCTMA

PERFTEST F6DCTMA

PERFTEST F6DCTMA

STOPTEST F6DCTMA

STOPTEST F6DCTMA

UNLOCK F6DCTMA

UNLOCK F6DCTMA

Phase2

Phase3

CREATE F6LNA

CREATE F6LNA

DELETE F6LNA

DELETE F6LNA

GET F6LNA

GET F6LNA

GETTEST F6LNA

GETTEST F6LNA

LOCK F6LNA

LOCK F6LNA

PERFTEST F6LNA

PERFTEST F6LNA

ETHPORT

Managed Element

Phase1

F6DCTMA

Managed Element

Phase1

F6LNA

42

Id:0900d80580598372

A50016-G5100-B333-04-7619

BS-4x / 82 II / 240 / 241 / 240XL commands

Managed Element

Phase1

Introduction

SET F6LNA

SET F6LNA

STOPTEST F6LNA

STOPTEST F6LNA

UNLOCK F6LNA

UNLOCK F6LNA

Phase2

Phase3

CREATE F6TNFP

CREATE F6TNFP

DELETE F6TNFP

DELETE F6TNFP

GET F6TNFP

GET F6TNFP

GETTEST F6TNFP

GETTEST F6TNFP

LOCK F6TNFP

LOCK F6TNFP

PERFTEST F6TNFP

PERFTEST F6TNFP

STOPTEST F6TNFP

STOPTEST F6TNFP

UNLOCK F6TNFP

UNLOCK F6TNFP

Phase2

Phase3

CREATE F6VSWRP

CREATE F6VSWRP

DELETE F6VSWRP

DELETE F6VSWRP

GET F6VSWRP

GET F6VSWRP

GETTEST F6VSWRP

GETTEST F6VSWRP

LOCK F6VSWRP

LOCK F6VSWRP

PERFTEST F6VSWRP

PERFTEST F6VSWRP

SET F6VSWRP

SET F6VSWRP

STOPTEST F6VSWRP

STOPTEST F6VSWRP

UNLOCK F6VSWRP

UNLOCK F6VSWRP

Phase2

Phase3

CREATE FANP

CREATE FANP

DELETE FANP

DELETE FANP

GET FANP

GET FANP

GETTEST FANP

GETTEST FANP

LOCK FANP

LOCK FANP

PERFTEST FANP

PERFTEST FANP

F6TNFP

Managed Element

Phase1

F6VSWRP

Managed Element

Phase1

FANP

A50016-G5100-B333-04-7619

Id:0900d80580598372

43

Introduction

Managed Element

BS-4x / 82 II / 240 / 241 / 240XL commands

Phase1

STOPTEST FANP

STOPTEST FANP

UNLOCK FANP

UNLOCK FANP

Phase2

Phase3

CREATE FCUMAIN

CREATE FCUMAIN

DELETE FCUMAIN

DELETE FCUMAIN

GET FCUMAIN

GET FCUMAIN

GET FCUMAIN FWID

GET FCUMAIN FWID

GET FCUMAIN WIRING

GET FCUMAIN WIRING

GETTEST FCUMAIN

GETTEST FCUMAIN

LOCK FCUMAIN

LOCK FCUMAIN

PERFTEST FCUMAIN

PERFTEST FCUMAIN

SET FCUMAIN

SET FCUMAIN

STOPTEST FCUMAIN

STOPTEST FCUMAIN

UNLOCK FCUMAIN

UNLOCK FCUMAIN

Phase2

Phase3

CREATE FCUTR

CREATE FCUTR

DELETE FCUTR

DELETE FCUTR

GET FCUTR

GET FCUTR

GETTEST FCUTR

GETTEST FCUTR

LOCK FCUTR

LOCK FCUTR

PERFTEST FCUTR

PERFTEST FCUTR

SET FCUTR

SET FCUTR

STOPTEST FCUTR

STOPTEST FCUTR

UNLOCK FCUTR

UNLOCK FCUTR

Phase2

Phase3

CREATE FTNFP

CREATE FTNFP

DELETE FTNFP

DELETE FTNFP

GET FTNFP

GET FTNFP

GETTEST FTNFP

GETTEST FTNFP

FCUMAIN

Managed Element

Phase1

FCUTR

Managed Element

Phase1

FTNFP

44

Id:0900d80580598372

A50016-G5100-B333-04-7619

BS-4x / 82 II / 240 / 241 / 240XL commands

Managed Element

Phase1

Introduction

LOCK FTNFP

LOCK FTNFP

PERFTEST FTNFP

PERFTEST FTNFP

STOPTEST FTNFP

STOPTEST FTNFP

UNLOCK FTNFP

UNLOCK FTNFP

Phase2

Phase3

CREATE FVSWRP

CREATE FVSWRP

DELETE FVSWRP

DELETE FVSWRP

GET FVSWRP

GET FVSWRP

GETTEST FVSWRP

GETTEST FVSWRP

LOCK FVSWRP

LOCK FVSWRP

PERFTEST FVSWRP

PERFTEST FVSWRP

STOPTEST FVSWRP

STOPTEST FVSWRP

UNLOCK FVSWRP

UNLOCK FVSWRP

Phase2

Phase3

CREATE LAPDLE

CREATE LAPDLE

DELETE LAPDLE

DELETE LAPDLE

GET LAPDLE

GET LAPDLE

Phase2

Phase3

FVSWRP

Managed Element

Phase1

LAPDLE

Managed Element

Phase1

LMU

The LMU function is no longer supported. Please do not use any LMU commands.

Managed Element

Phase1

Phase2

Phase3

CREATE RACK

CREATE RACK

DELETE RACK

DELETE RACK

GET RACK

GET RACK

LOCK RACK

LOCK RACK

RACK

SET RACK

Managed Element

Phase1

A50016-G5100-B333-04-7619

UNLOCK RACK

UNLOCK RACK

Phase2

Phase3

Id:0900d80580598372

45

Introduction

BS-4x / 82 II / 240 / 241 / 240XL commands

REMINV

Managed Element

DNLIDFD REMINV

DNLIDFD REMINV

UPLLIDF REMINV

UPLLIDF REMINV

UPLLIDF REMINV

Phase1

Phase2

Phase3

DNLALLEXE
SOFTWARE-MANAGEMENT

DNLALLEXE
SOFTWARE-MANAGEMENT

SOFTWARE-MANAGEMENT

Managed Element

Phase1

UPLBTSLOG
SOFTWARE-MANAGEMENT

UPLBTSLOG
SOFTWARE-MANAGEMENT

Phase2

Phase3

GET SYNCBTSE

GET SYNCBTSE

GETTEST SYNCBTSE

GETTEST SYNCBTSE

LOCK SYNCBTSE

LOCK SYNCBTSE

PERFTEST SYNCBTSE

PERFTEST SYNCBTSE

SET SYNCBTSE

SET SYNCBTSE

STOPTEST SYNCBTSE

STOPTEST SYNCBTSE

UNLOCK SYNCBTSE

UNLOCK SYNCBTSE

Phase2

Phase3

CREATE TMA

CREATE TMA

DELETE TMA

DELETE TMA

GET TMA

GET TMA

GET TMA PRODUCTINFO

GET TMA PRODUCTINFO

GETTEST TMA

GETTEST TMA

LOCK TMA

LOCK TMA

PERFTEST TMA

PERFTEST TMA

STOPTEST TMA

STOPTEST TMA

UNLOCK TMA

UNLOCK TMA

SYNCBTSE

Managed Element

Phase1

TMA

46

Id:0900d80580598372

A50016-G5100-B333-04-7619

BS-4x / 82 II / 240 / 241 / 240XL commands

Managed Element

Phase1

Introduction

Phase2

Phase3

TRX
GET TRX
GETRELATIONSHIP
TRX

Managed Element

Phase1

Phase2

Phase3

CREATE XCONNECT

CREATE XCONNECT

DELETE XCONNECT

DELETE XCONNECT

GET XCONNECT

GET XCONNECT

LOCK XCONNECT

LOCK XCONNECT

SET XCONNECT

SET XCONNECT

UNLOCK XCONNECT

UNLOCK XCONNECT

XCONNECT

A50016-G5100-B333-04-7619

Id:0900d80580598372

47

Objects and commands in alphabetical order

BS-4x / 82 II / 240 / 241 / 240XL commands

2 Objects and commands in alphabetical order

48

Id:0900d80580248205

A50016-G5100-B333-04-7619

BS-4x / 82 II / 240 / 241 / 240XL commands

ACDCP

ACDCP
The ACDCP converter consists of two different power supply and control units: ACPSC
(AC power supply, charging and supervising of the battery backup system) and DCPSC
(DC power supply).

CREATE ACDCP
CREATE ACDCP

NAME=RACK:0..7/ACDCP:0..1;

Command Tree:
MANAGED-ELEMENT h BSS-EQUIPMENT h BTSEP h RACK h ACDCP h
CREATE ACDCP
Applicability:
Phase 2 and Phase 3.
Visibility level: 2.
Command Description:
This command adds the AC/DC Converter Panel to the BTSE data base.
Long Names:
NAME

Address of the managed object

System Responses:
Operation Completed
After command execution, a message of Changed Configuration Notification is displayed.
A further message indicates the result of the operation. An example of create command
is the following:
JOB: 41
PC Time&Date: 11:55:28 03/23/2005
NE Time&Date: 12:57:03 09/15/2004
USER NAME:

User_a

COMMAND:

Create ACDCP:NAME=RACK:0/ACDCP:0;

SW RELEASE:

01-04-17-01-26-51_05-02-23

COMMAND RESULT: Operation successful


END OF OUTPUT FOR JOB 41
JOB: 42

A50016-G5100-B333-04-7619

Id:0900d80580593f21

49

ACDCP

BS-4x / 82 II / 240 / 241 / 240XL commands

PC Time&Date: 11:55:28 03/23/2005


NE Time&Date: 12:57:03 09/15/2004
USER NAME:

User_a

SW RELEASE:

01-04-17-01-26-51_05-02-23

COMMAND RESULT: Operation successful


CHANGED STATE EVENT REPORT:
NAME = RACK:0/ACDCP:0
Availability Status = NULL_value
Notification Identifier = 284
END OF OUTPUT FOR JOB 42
Operation Failed
The specified Object has not been created. In addition to the general NACK causes, a
specific NACK cause, which indicates that the command is inconsistent with the
physical configuration, is possible. An example is the following:
JOB: 43
PC Time&Date: 11:55:28 03/23/2005
NE Time&Date: 12:57:03 09/15/2004
USER NAME:

User_a

COMMAND:

Create ACDCP:NAME=RACK:0/ACDCP:1;

SW RELEASE:

01-04-17-01-26-51_05-02-23

COMMAND RESULT: OPERATION FAILED


MO already created (-159)
END OF OUTPUT FOR JOB 43
Application Guidelines:

The ACDCP is not necessary for the BS240

The ACDCP can not be created for the BS240 Compact Site as it is equipped in the
Energy Station Rack which is not supervised by the SW

The ACDCP can not be created for the BS240, BS241, BS240XL, BS40II

Example of Command Execution:


Create ACDCP:NAME=RACK:0/ACDCP:0;

50

Id:0900d80580593f21

A50016-G5100-B333-04-7619

BS-4x / 82 II / 240 / 241 / 240XL commands

ACDCP

DELETE ACDCP
DELETE ACDCP

NAME=RACK:0..7/ACDCP:0..1;

Command Tree:
MANAGED-ELEMENT h BSS-EQUIPMENT h BTSEP h RACK h ACDCP h
DELETE ACDCP
Applicability:
Phase 2 and Phase 3.
Visibility level: 2.
Command Description:
This command deletes the AC/DC Converter Panel from the BTSE data base.
Long Names:
NAME

Address of the managed object

System Responses:
Operation Completed
After command execution, a message of Changed Configuration Notification is displayed. A further message indicates the result of the operation. An example of delete
command is the following:
JOB: 38
PC Time&Date: 11:55:25 03/23/2005
NE Time&Date: 12:57:00 09/15/2004
USER NAME:

User_a

SW RELEASE:

01-04-17-01-26-51_05-02-23

COMMAND RESULT: Operation successful


ChangedConfigurationNotification:
name = RACK:0/ACDCP:0
ChangeInfo = deleted
END OF OUTPUT FOR JOB 38
JOB: 39
PC Time&Date: 11:55:25 03/23/2005
NE Time&Date: 12:57:00 09/15/2004

A50016-G5100-B333-04-7619

Id:0900d80580593f21

51

ACDCP

BS-4x / 82 II / 240 / 241 / 240XL commands

USER NAME:

User_a

COMMAND:

Delete ACDCP:NAME=RACK:0/ACDCP:0;

SW RELEASE:

01-04-17-01-26-51_05-02-23

COMMAND RESULT: Operation successful


END OF OUTPUT FOR JOB 39
Operation Failed
The specified Object has not been deleted. Additionally to the general NACK causes, a
specific NACK cause, meaning that the command is inconsistent with physical configuration, is possible.
Application Guidelines:

ACDCP must be locked in phase 3 before deletion

The ACDCP can not be deleted for the BS-240 Compact Site as it is equipped in the
Energy Station Rack which is not supervised by the SW

The ACDCP can not be deleted for the BS-40II

Example of Command Execution:


Delete ACDCP:NAME=RACK:0/ACDCP:0;

GET ACDCP
GET ACDCP

NAME=RACK:0..7/ACDCP:0..1 [,REQATTL=ALS, AST,


AVS, OST, PRS, RELFUNCOBJ];

Command Tree:
MANAGED-ELEMENT h BSS-EQUIPMENT h BTSEP h RACK h ACDCP h
GET ACDCP
Applicability:
Phase 2 and Phase 3.
Visibility level: 0.
Command Description:
This command displays the attributes of the AC/DC converter Panel of the BTSE.
Long Names:

52

NAME

Address of the managed object

REQATTL

Required attribute list

ALS

alarmStatus

AST

administrativeState

AVS

availabilityStatus

OST

operationalState

PRS

proceduralStatus

Id:0900d80580593f21

A50016-G5100-B333-04-7619

BS-4x / 82 II / 240 / 241 / 240XL commands

RELFUNCOBJ

ACDCP

relatedFuncObjects

System Responses:
Operation Completed
A message indicates the result of the operation. An example of get command is the following:
JOB: 23
PC Time&Date: 11:55:04 03/23/2005
NE Time&Date: 12:56:39 09/15/2004
USER NAME:

User_a

COMMAND:

Get ACDCP:NAME=RACK:0/ACDCP:0;

SW RELEASE:

01-04-17-01-26-51_05-02-23

COMMAND RESULT: Operation successful


alarmStatus = CLEARED
administrativeState = Unlocked
availabilityStatus = NULL
operationalState = ENABLED
proceduralStatus = NULL
relatedFuncObjects =
END OF OUTPUT FOR JOB 23
Operation Failed
The GET command has not been successfully executed. A general NACK will indicate
possible errors or a specific NACK strictly related to the single command is possible.
Application Guidelines:

The GET ACDCP command cannot be issued for the BS-240 Compact Site as the
ACDCP is equipped in the Energy Station Rack which is not supervised by the SW

The GET ACDCP command cannot be issued for the BS-40II

Example of Command Execution:


Get ACDCP:NAME=RACK:0/ACDCP:0,REQATTL=ALS&AST&AVS&OST&PRS&
RELFUNCOBJ;

GETTEST ACDCP
GETTEST ACDCP

A50016-G5100-B333-04-7619

NAME=RACK:0..7/ACDCP:0..1;

Id:0900d80580593f21

53

ACDCP

BS-4x / 82 II / 240 / 241 / 240XL commands

Command Tree:
MANAGED-ELEMENT h BSS-EQUIPMENT h BTSEP h RACK h ACDCP h
GETTEST ACDCP
Applicability:
Phase 2 and Phase 3.
Visibility level: 0.
Command Description:
This command displays the attributes of the AC/DC converter test.
Long Names:
NAME

Address of the managed object

REQATTL

Required attribute list

System Responses:
Operation Completed
A message indicates the result of the operation. An example of gettest command is the
following:
JOB: 36
PC Time&Date: 11:55:22 03/23/2005
NE Time&Date: 12:56:57 09/15/2004
USER NAME:

User_a

COMMAND:

Gettest ACDCP:NAME=RACK:0/ACDCP:0;

SW RELEASE:

01-04-17-01-26-51_05-02-23

COMMAND RESULT: Operation successful


MOT = RACK:0/ACDCP:0
testMonitor =
phaseId = PreliminaryTestsAcdcp
phaseStatus = Running
phaseId = CheckAlarmStatusAcdcp
phaseStatus = Waiting
phaseId = EndTestAcdcp
phaseStatus = Waiting
testOutcome = INCONCLUSIVE
testState = INITIALIZING
END OF OUTPUT FOR JOB 36

54

Id:0900d80580593f21

A50016-G5100-B333-04-7619

BS-4x / 82 II / 240 / 241 / 240XL commands

ACDCP

Operation Failed
The GET command has not been successfully executed. A general NACK will indicate
possible errors or a specific NACK strictly related to the single command is possible.
testMonitor
phaseId =
phaseStatus =

it is a list of all test phases related to the


selected object; for each phase the
related phaseStatus is provided (Passed,
Failed, Running or Waiting).

phaseId =
phaseStatus =
...
...
testOutcome

It represents the test result: it can be


Inconclusive (if the phases already
executed were successful) or Fail (if at
least one of the executed phases failed).

testState = Testing

It can assume one of the following values:


not_initialized, idle, initializing, suspended, testing, terminating and disabled.

Application Guidelines:
None.
Example of Command Execution:
Gettest ACDCP:NAME=RACK:0/ACDCP:0;

LOCK ACDCP
LOCK ACDCP

NAME=RACK:0..7/ACDCP:0..1;

Command Tree:
MANAGED-ELEMENT h BSS-EQUIPMENT h BTSEP h RACK h ACDCP h
LOCK ACDCP
Applicability:
Phase 2 and Phase 3.
Visibility level: 1.
Command Description:
This command changes the administrative state of AC/DC converter Panel of the BTSE.
Long Names:
NAME

Address of the managed object

System Responses:
Operation Completed
The specified change of administrative state has been perfomed:

A50016-G5100-B333-04-7619

Id:0900d80580593f21

55

ACDCP

BS-4x / 82 II / 240 / 241 / 240XL commands

JOB: 24
PC Time&Date: 11:55:06 03/23/2005
NE Time&Date: 12:56:41 09/15/2004
USER NAME:

User_a

COMMAND:

Lock ACDCP:NAME=RACK:0/ACDCP:0;

SW RELEASE:

01-04-17-01-26-51_05-02-23

COMMAND RESULT: Operation successful


administrativeState = Locked
END OF OUTPUT FOR JOB 24

CHANGED STATE EVENT REPORT:


This provides information about the administrative state, the operational state and the
availability status every time a state change occurs:
JOB: 25
PC Time&Date: 11:55:06 03/23/2005
NE Time&Date: 12:56:41 09/15/2004
USER NAME:

User_a

SW RELEASE:

01-04-17-01-26-51_05-02-23

COMMAND RESULT: Operation successful


CHANGED STATE EVENT REPORT:
NAME = RACK:0/ACDCP:0
Administrative State = LOCKED
Notification Identifier = 271
END OF OUTPUT FOR JOB 25
Operation Failed
The specified change of administrative state has not been performed (e.g. the object is
redundant and its spare copy is disabled or already locked, a subordinate resource
cannot go into disabled state with "dependency" availability status).

56

Id:0900d80580593f21

A50016-G5100-B333-04-7619

BS-4x / 82 II / 240 / 241 / 240XL commands

ACDCP

Application Guidelines:

The ACDCP can not be locked for the BS-240 Compact Site as it is equipped in the
Energy Station Rack which is not supervised by the SW

The ACDCP can not be locked for the BS-40II

Example of Command Execution:


Lock ACDCP:NAME=RACK:0/ACDCP:0;

PERFTEST ACDCP
PERFTEST ACDCP

NAME=RACK:0..7/ACDCP:0..1;

Command Tree:
MANAGED-ELEMENT h BSS-EQUIPMENT h BTSEP h RACK h ACDCP h
PERFTEST ACDCP
Applicability:
Phase 2 and Phase 3.
Visibility level: 1.
Command Description:
This command requests the execution of a test performed by the ACDCP.
Long Names:
NAME

Address of the managed object

System Responses:
Operation Completed
Test configuration has been set and the specified test has been started. The System
response will not be addressed to the MOT but to the object BTSEP.
JOB: 27
PC Time&Date: 11:55:09 03/23/2005
NE Time&Date: 12:56:44 09/15/2004
USER NAME:

User_a

COMMAND:

Perftest ACDCP:NAME=RACK:0/ACDCP:0;

SW RELEASE:

01-04-17-01-26-51_05-02-23

COMMAND RESULT: Operation successful


MOT = RACK:0/ACDCP:0
tO = BTSETEST:3
END OF OUTPUT FOR JOB 27

A50016-G5100-B333-04-7619

Id:0900d80580593f21

57

ACDCP

BS-4x / 82 II / 240 / 241 / 240XL commands

JOB: 28
PC Time&Date: 11:55:09 03/23/2005
NE Time&Date: 12:56:44 09/15/2004
USER NAME:

User_a

SW RELEASE:

01-04-17-01-26-51_05-02-23

COMMAND RESULT: Operation successful


ChangedConfigurationNotification:
name = BTSETEST:3
ChangeInfo = created
END OF OUTPUT FOR JOB 28
JOB: 29
PC Time&Date: 11:55:09 03/23/2005
NE Time&Date: 12:56:44 09/15/2004
USER NAME:

User_a

SW RELEASE:

01-04-17-01-26-51_05-02-23

COMMAND RESULT: Operation successful


CHANGED STATE EVENT REPORT:
NAME = RACK:0/ACDCP:0
Operational State = ENABLED
Availability Status = NULL_value
Notification Identifier = 275
END OF OUTPUT FOR JOB 29
JOB: 30
PC Time&Date: 11:55:09 03/23/2005
NE Time&Date: 12:56:44 09/15/2004

58

Id:0900d80580593f21

A50016-G5100-B333-04-7619

BS-4x / 82 II / 240 / 241 / 240XL commands

ACDCP

USER NAME:

User_a

SW RELEASE:

01-04-17-01-26-51_05-02-23

COMMAND RESULT: Operation successful


Test Report:
name = BTSETEST:3
testOutcome = PASSED
testTermination = Normal
MOT = RACK:0/ACDCP:0
executedPhases =
PreliminaryTestsAcdcp
CheckAlarmStatusAcdcp
EndTestAcdcp
END OF OUTPUT FOR JOB 30
JOB: 31
PC Time&Date: 11:55:09 03/23/2005
NE Time&Date: 12:56:44 09/15/2004
USER NAME:

User_a

SW RELEASE:

01-04-17-01-26-51_05-02-23

COMMAND RESULT: Operation successful


ChangedConfigurationNotification:
name = BTSETEST:3
ChangeInfo = deleted
END OF OUTPUT FOR JOB 31
The test results will be displayed at the end of the test phases.
Result TEST:

A50016-G5100-B333-04-7619

name =

TEST:<n>

testOutcome =

This field represents the test result; one of the following values can be displayed:

Id:0900d80580593f21

59

ACDCP

BS-4x / 82 II / 240 / 241 / 240XL commands

Pass

all the test phases are successfully


performed.

Inconclusive

the test is aborted by the system or


the test is terminated by the operator.

Fail

if at least one of the executed phases


fail.

mOts =

It is the identifier of the hardware object under test.

testTermination =

It specifies how the test is terminated, it can assume


the following values:
Normal

all the test phases are performed.

Abort

the test is aborted by system.

Cancel

the test is terminated by operator.

executedPhases
phaseId =
additionalWords =
....

It represents the list of the executed test phases (in


case of successful test result, all the test phases will
be listed).

failedPhases
phaseId =

It represents the list of the failed test phase; additional information is provided for each phase.

phaseId =
....
skippedPhases
phaseId =

It represents the list of the skipped phases; they are


displayed only for test stopped during it execution.

phaseId =
....
poprosedRepair Action
=

A list of most probable fail probable causes is shown


(max four messages)

Operation Failed
This NACK-message occurs in the following cases: Message cannot be performed, test
not supported, capacity restrictions, physical configuration cannot be performed, object
not locked.
Application Guidelines:

In phase 3 MO must be locked previous to the command execution

Example of Command Execution:


Perftest ACDCP:NAME=RACK:0/ACDCP:0;

STOPTEST ACDCP
STOPTEST ACDCP

60

NAME=RACK:0..7/ACDCP:0..1;

Id:0900d80580593f21

A50016-G5100-B333-04-7619

BS-4x / 82 II / 240 / 241 / 240XL commands

ACDCP

Command Tree:
MANAGED-ELEMENT h BSS-EQUIPMENT h BTSEP h RACK h ACDCP h
STOPTEST ACDCP
Applicability:
Phase 2 and Phase 3.
Visibility level: 1.
Command Description:
This command stops a test performed by ACDCP.
Long Names:
NAME

Address of the managed object

System Responses:
Operation Completed
Test has been stopped. The System Responses will not be addressed to the MOT but
to the object BTSEP.

Result TEST:
name =

TEST:<n>

testOutcome =

inconclusive

mOts =

It is the identifier of the hardware object under test.

testTermination =

Cancel

executedPhases
phaseId =

It represents the list of the executed test phases; the


list is not shown for test in the waiting list (queued).

...
.
failedPhases
phaseId =

It represents the list of the failed test phase;

phaseId =

additional information is provided for each phase.

....
skippedPhases
phaseId =

It represents the list of the skipped phases;the list is


not shown for test in the waiting list (queued).

phaseId =
Operation Failed

Test has not been stopped. This NACK-message can occur when the specified test is
not running or in case of test which cannot be stopped.
Application Guidelines:
None.

A50016-G5100-B333-04-7619

Id:0900d80580593f21

61

ACDCP

BS-4x / 82 II / 240 / 241 / 240XL commands

Example of Command Execution:


Stoptest ACDCP:NAME=RACK:0/ACDCP:0;

UNLOCK ACDCP
UNLOCK ACDCP

NAME=RACK:0..7/ACDCP:0..1;

Command Tree:
MANAGED-ELEMENT h BSS-EQUIPMENT h BTSEP h RACK h ACDCP h
UNLOCK ACDCP
Applicability:
Phase 2 and Phase 3.
Visibility level: 1.
Command Description:
This command changes the administrative state of AC/DC converter.
Long Names:
NAME

Address of the managed object

System Responses:
Operation Completed
The specified change of administrative state has been perfomed:
JOB: 34
PC Time&Date: 11:55:18 03/23/2005
NE Time&Date: 12:56:53 09/15/2004
USER NAME:

User_a

COMMAND:

Unlock ACDCP:NAME=RACK:0/ACDCP:0;

SW RELEASE:

01-04-17-01-26-51_05-02-23

COMMAND RESULT: Operation successful


administrativeState = Unlocked
END OF OUTPUT FOR JOB 34

CHANGED STATE EVENT REPORT:


This provides information about the administrative state, the operational state and the
availability status every time a state change occurs:

62

Id:0900d80580593f21

A50016-G5100-B333-04-7619

BS-4x / 82 II / 240 / 241 / 240XL commands

ACDCP

JOB: 35
PC Time&Date: 11:55:18 03/23/2005
NE Time&Date: 12:56:53 09/15/2004
USER NAME:

User_a

SW RELEASE:

01-04-17-01-26-51_05-02-23

COMMAND RESULT: Operation successful


CHANGED STATE EVENT REPORT:
NAME = RACK:0/ACDCP:0
Administrative State = UNLOCKED
Notification Identifier = 280
END OF OUTPUT FOR JOB 35
Operation Failed
The specified change of administrative state has not been performed.
Application Guidelines:

The ACDCP can not be unlocked for the BS-240 Compact Site as it is equipped in
the Energy Station Rack which is not supervised by the SW

The ACDCP can not be unlocked for the BS-40II

Example of Command Execution:


Unlock ACDCP:NAME=RACK:0/ACDCP:0;

A50016-G5100-B333-04-7619

Id:0900d80580593f21

63

ACT

BS-4x / 82 II / 240 / 241 / 240XL commands

ACT
The ACT (Alarm Collection Terminal) object represents the terminal for the collection of
the alarms.

CREATE ACT
CREATE ACT

NAME=RACK:0..7/ACT:0..0;

Command Tree:
MANAGED-ELEMENT h BSS-EQUIPMENT h BTSEP h RACK h ACT h
CREATE ACT
Applicability:
Phase 2 and Phase 3.
Visibility level: 2.
Command Description:
This command adds the ACT (Alarm Collection Terminal) to the BTSE data base. The
ACT contains the interface to the external alarms (Operator alarms, rack alarms, shelter
alarms,...) and commands and a CAN-BUS interface to the CORE.
Long Names:
NAME

Address of the managed object

System Responses:
Operation Completed
After command execution, a message of Changed Configuration Notification is displayed.
A further message indicates the result of the operation. An example of create command
is the following:
JOB: 187
PC Time&Date: 16:48:48 03/23/2005
NE Time&Date: 16:46:42 09/15/2004
USER NAME:

User_b

SW RELEASE:

01-04-17-01-26-51_05-02-23

COMMAND RESULT: Operation successful


ChangedConfigurationNotification:
name = RACK:0/ACT:0
ChangeInfo = created

64

Id:0900d80580593f23

A50016-G5100-B333-04-7619

BS-4x / 82 II / 240 / 241 / 240XL commands

ACT

END OF OUTPUT FOR JOB 187


JOB: 188
PC Time&Date: 16:48:48 03/23/2005
NE Time&Date: 16:46:42 09/15/2004
USER NAME:

User_b

COMMAND:

Create ACT:NAME=RACK:0/ACT:0;

SW RELEASE:

01-04-17-01-26-51_05-02-23

COMMAND RESULT: Operation successful


END OF OUTPUT FOR JOB 188
Operation Failed
The specified Object has not been created. In addition to the general NACK causes, a
specific NACK cause, which indicates that the command is inconsistent with the
physical configuration, is possible. An example is the following:
JOB: 72
PC Time&Date: 16:37:54 03/23/2005
NE Time&Date: 16:35:47 09/15/2004
USER NAME:

User_b

COMMAND:

Create ACT:NAME=RACK:0/ACT:0;

SW RELEASE:

01-04-17-01-26-51_05-02-23

COMMAND RESULT: OPERATION FAILED


Message cannot be performed (-17)
END OF OUTPUT FOR JOB 72

Application Guidelines:

The ACTC which is a part of the DC Panel and it is always present in every rack to
collect all internal alarms. It has inputs for 16 internal alarms (1 Door, 6 Fans and 9
rack/shelter internal alarms, which can be defined by the operator). The ACTC
supports 9 ENVAs within the range from 0...8. BS82II support 5 internal alarms (1
Door, 1 Fans and 3 rack/shelter internal alarms, which can be defined by the operator)

A50016-G5100-B333-04-7619

Id:0900d80580593f23

65

ACT

BS-4x / 82 II / 240 / 241 / 240XL commands

An ACTM for 48 alarms and 8 commands is used only in the Base Rack to support
the external alarm and command interface for the operator. The ACTM consists of
two boards: the ACTA (Alarm and Command Interfaces) and the ACTP (Processor
Core). The ACTP sends the alarms to the CORE via the CAN BUS.

For the Extension Racks and the Service Racks only few alarms (e.g. temperature
supervision, FAN, ACDC alarms,..) are necessary, so an ACTP with 16 alarm or site
inputs is used. The ACTP sends the alarms to the CORE via the CAN BUS.

On a BS82II (base and extension racks) temp., RDO, FAN alarms are controlled by
the ACT (on other platforms from COBA in Base rack), these inputs are only handled
in a correct way if the ACT is created successfully.

Example of Command Execution:


Create ACT:NAME=RACK:0/ACT:0;

DELETE ACT
DELETE ACT

NAME=RACK:0..7/ACT:0..0;

Command Tree:
MANAGED-ELEMENT h BSS-EQUIPMENT h BTSEP h RACK h ACT h
DELETE ACT
Applicability:
Phase 2 and Phase 3.
Visibility level: 2.
Command Description:
This command deletes the ACT (Alarm Collection Terminal) from the BTSE data base.
Long Names:
NAME

Address of the managed object

System Responses:
Operation Completed
After command execution, a message of Changed Configuration Notification is displayed. A further message indicates the result of the operation. An example of delete
command is the following:
JOB: 196
PC Time&Date: 16:49:26 03/23/2005
NE Time&Date: 16:47:20 09/15/2004
USER NAME:

User_b

SW RELEASE:

01-04-17-01-26-51_05-02-23

COMMAND RESULT: Operation successful

66

Id:0900d80580593f23

A50016-G5100-B333-04-7619

BS-4x / 82 II / 240 / 241 / 240XL commands

ACT

ChangedConfigurationNotification:
name = RACK:0/ACT:0
ChangeInfo = deleted
END OF OUTPUT FOR JOB 196
JOB: 197
PC Time&Date: 16:49:26 03/23/2005
NE Time&Date: 16:47:20 09/15/2004
USER NAME:

User_b

COMMAND:

Delete ACT:NAME=RACK:0/ACT:0;

SW RELEASE:

01-04-17-01-26-51_05-02-23

COMMAND RESULT: Operation successful


END OF OUTPUT FOR JOB 197
Operation Failed
The specified Object has not been deleted. Additionally to the general NACK causes, a
specific NACK cause, meaning that the command is inconsistent with physical configuration, is possible.
Application Guidelines:

ACT must be locked in phase 3 before deletion

Example of Command Execution:


Delete ACT:NAME=RACK:0/ACT:0;

GET ACT
GET ACT

NAME=RACK:0..7/ACT:0..0 [,REQATTL=ALS, AST, AVS,


OST, PRS, RELFUNCOBJ];

Command Tree:
MANAGED-ELEMENT h BSS-EQUIPMENT h BTSEP h RACK h ACT h GET
ACT
Applicability:
Phase 2 and Phase 3.
Visibility level: 0.

A50016-G5100-B333-04-7619

Id:0900d80580593f23

67

ACT

BS-4x / 82 II / 240 / 241 / 240XL commands

Command Description:
This command displays the attributes of the ACT (Alarm Collection Terminal).
Long Names:
NAME

Address of the managed object

REQATTL

Required attribute list

ALS

alarmStatus

AST

administrativeState

AVS

availabilityStatus

OST

operationalState

PRS

proceduralStatus

RELFUNCOBJ

relatedFuncObjects

System Responses:
Operation Completed
A message indicates the result of the operation. An example of get command is the following:
JOB: 189
PC Time&Date: 16:49:05 03/23/2005
NE Time&Date: 16:46:59 09/15/2004
USER NAME:

User_b

COMMAND:

Get ACT:NAME=RACK:0/ACT:0;

SW RELEASE:

01-04-17-01-26-51_05-02-23

COMMAND RESULT: Operation successful


alarmStatus = CLEARED
administrativeState = Unlocked
availabilityStatus = NotInstalled
operationalState = DISABLED
proceduralStatus = NULL
relatedFuncObjects =
END OF OUTPUT FOR JOB 189
Operation Failed
The GET command has not been successfully executed. A general NACK will indicate
possible errors or a specific NACK strictly related to the single command is possible.
Application Guidelines:
None.

68

Id:0900d80580593f23

A50016-G5100-B333-04-7619

BS-4x / 82 II / 240 / 241 / 240XL commands

ACT

Example of Command Execution:


Get ACT:NAME=RACK:0/ACT:0,REQATTL=ALS&AST&AVS&OST&
PRS&RELFUNCOBJ;

GETTEST ACT
GETTEST ACT

NAME=RACK:0..7/ACT:0..0;

Command Tree:
MANAGED-ELEMENT h BSS-EQUIPMENT h BTSEP h RACK h ACT h
GETTEST ACT
Applicability:
Phase 2 and Phase 3.
Visibility level: 0.
Command Description:
This command displays the attributes of the ACT (Alarm Collection Terminal) test.
Long Names:
NAME

Address of the managed object

REQATTL

Required attribute list

System Responses:
Operation Completed
A message indicates the result of the operation. An example of gettest command is the
following:
JOB: 26
PC Time&Date: 11:55:09 03/23/2005
NE Time&Date: 12:56:44 09/15/2004
USER NAME:

User_b

COMMAND:

Gettest ACT:NAME=RACK:0/ACT:0;

SW RELEASE:

01-04-17-01-26-51_05-02-23

COMMAND RESULT: Operation successful


MOT = RACK:0/ACT:0
testMonitor =
phaseId = PreliminaryTestsAct
phaseStatus = Running
phaseId = CheckAlarmStatusAct
phaseStatus = Waiting

A50016-G5100-B333-04-7619

Id:0900d80580593f23

69

ACT

BS-4x / 82 II / 240 / 241 / 240XL commands

phaseId = EndTestAct
phaseStatus = Waiting
testOutcome = INCONCLUSIVE
testState = INITIALIZING
END OF OUTPUT FOR JOB 26
Operation Failed
The GET command has not been successfully executed. A general NACK will indicate
possible errors or a specific NACK strictly related to the single command is possible.
testMonitor
phaseId =
phaseStatus =

it is a list of all test phases related to the


selected object; for each phase the
related phaseStatus is provided (Passed,
Failed, Running or Waiting).

phaseId =
phaseStatus =
...
...
testOutcome

It represents the test result: it can be


Inconclusive (if the phases already
executed were successful) or Fail (if at
least one of the executed phases failed).

testState = Testing

It can assume one of the following values:


not_initialized, idle, initializing, suspended, testing, terminating and disabled.

Application Guidelines:
None.
Example of Command Execution:
Gettest ACT:NAME=RACK:0/ACT:0,REQATTL=ALS&AST&AVS&OST&PRS;

LOCK ACT
LOCK ACT

NAME=RACK:0..7/ACT:0..0;

Command Tree:
MANAGED-ELEMENT h BSS-EQUIPMENT h BTSEP h RACK h ACT h LOCK
ACT
Applicability:
Phase 2 and Phase 3.
Visibility level: 1.

70

Id:0900d80580593f23

A50016-G5100-B333-04-7619

BS-4x / 82 II / 240 / 241 / 240XL commands

ACT

Command Description:
This command changes the administrative state of ACT (Alarm Collection Terminal).
Long Names:
NAME

Address of the managed object

System Responses:
Operation Completed
The specified change of administrative state has been perfomed:
JOB: 190
PC Time&Date: 16:49:10 03/23/2005
NE Time&Date: 16:47:04 09/15/2004
USER NAME:

User_b

COMMAND:

Lock ACT:NAME=RACK:0/ACT:0;

SW RELEASE:

01-04-17-01-26-51_05-02-23

COMMAND RESULT: Operation successful


administrativeState = Locked
END OF OUTPUT FOR JOB 190

CHANGED STATE EVENT REPORT:


This provides information about the administrative state, the operational state and the
availability status every time a state change occurs:
JOB: 191
PC Time&Date: 16:49:10 03/23/2005
NE Time&Date: 16:47:04 09/15/2004
USER NAME:

User_b

SW RELEASE:

01-04-17-01-26-51_05-02-23

COMMAND RESULT: Operation successful


CHANGED STATE EVENT REPORT:
NAME = RACK:0/ACT:0

A50016-G5100-B333-04-7619

Id:0900d80580593f23

71

ACT

BS-4x / 82 II / 240 / 241 / 240XL commands

Administrative State = LOCKED


Notification Identifier = 566
END OF OUTPUT FOR JOB 191
Operation Failed
The specified change of administrative state has not been performed.
Application Guidelines:
None.
Example of Command Execution:
Lock ACT:NAME=RACK:0/ACT:0;

PERFTEST ACT
PERFTEST ACT

NAME=RACK:0..7/ACT:0..0;

Command Tree:
MANAGED-ELEMENT h BSS-EQUIPMENT h BTSEP h RACK h ACT h
PERFTEST ACT
Applicability:
Phase 2 and Phase 3.
Visibility level: 1.
Command Description:
This command changes the administrative state of ACT (Alarm Collection Terminal).
Long Names:
NAME

Address of the managed object

System Responses:
Operation Completed
Test configuration has been set and the specified test has been started. The System
response will not be addressed to the MOT but to the object BTSEP.
JOB: 36
PC Time&Date: 11:55:22 03/23/2005
NE Time&Date: 12:56:57 09/15/2004
USER NAME:

User_b

COMMAND:

Perftest ACT:NAME=RACK:0/ACT:0;

SW RELEASE:

01-04-17-01-26-51_05-02-23

COMMAND RESULT: Operation successful

72

Id:0900d80580593f23

A50016-G5100-B333-04-7619

BS-4x / 82 II / 240 / 241 / 240XL commands

ACT

MOT = RACK:0/ACT:0
tO = BTSETEST:2
END OF OUTPUT FOR JOB 36
JOB: 37
PC Time&Date: 11:55:22 03/23/2005
NE Time&Date: 12:56:57 09/15/2004
USER NAME:

User_b

SW RELEASE:

01-04-17-01-26-51_05-02-23

COMMAND RESULT: Operation successful


ChangedConfigurationNotification:
name = BTSETEST:2
ChangeInfo = created
END OF OUTPUT FOR JOB 37
JOB: 38
PC Time&Date: 11:55:25 03/23/2005
NE Time&Date: 12:57:00 09/15/2004
USER NAME:

User_b

SW RELEASE:

01-04-17-01-26-51_05-02-23

COMMAND RESULT: Operation successful


CHANGED STATE EVENT REPORT:
NAME = RACK:0/ACT:0
Operational State = ENABLED
Availability Status = NULL_value
Notification Identifier = 128

A50016-G5100-B333-04-7619

Id:0900d80580593f23

73

ACT

BS-4x / 82 II / 240 / 241 / 240XL commands

END OF OUTPUT FOR JOB 38


JOB: 39
PC Time&Date: 11:55:25 03/23/2005
NE Time&Date: 12:57:00 09/15/2004
USER NAME:

User_b

SW RELEASE:

01-04-17-01-26-51_05-02-23

COMMAND RESULT: Operation successful


Test Report:
name = BTSETEST:2
testOutcome = PASSED
testTermination = Normal
MOT = RACK:0/ACT:0
executedPhases =
PreliminaryTestsAct
CheckAlarmStatusAct
EndTestAct
END OF OUTPUT FOR JOB 39
JOB: 40
PC Time&Date: 11:55:28 03/23/2005
NE Time&Date: 12:57:03 09/15/2004
USER NAME:

User_b

SW RELEASE:

01-04-17-01-26-51_05-02-23

COMMAND RESULT: Operation successful


ChangedConfigurationNotification:
name = BTSETEST:2
ChangeInfo = deleted
END OF OUTPUT FOR JOB 40

74

Id:0900d80580593f23

A50016-G5100-B333-04-7619

BS-4x / 82 II / 240 / 241 / 240XL commands

ACT

The test results will be displayed at the end of the test phases.
Result TEST:
name =

TEST:<n>

testOutcome =

This field represents the test result; one of the following values can be displayed:
Pass

all the test phases are successfully


performed.

Inconclusive

the test is aborted by the system or


the test is terminated by the operator.

Fail

if at least one of the executed phases


fail.

mOts =

It is the identifier of the hardware object under test.

testTermination =

It specifies how the test is terminated, it can assume


the following values:
Normal

all the test phases are performed.

Abort

the test is aborted by system.

Cancel

the test is terminated by operator.

executedPhases
phaseId =
additionalWords =
....

It represents the list of the executed test phases (in


case of successful test result, all the test phases will
be listed).

failedPhases
phaseId =

It represents the list of the failed test phase; additional information is provided for each phase.

phaseId =
....
skippedPhases
phaseId =

It represents the list of the skipped phases; they are


displayed only for test stopped during it execution.

phaseId =
....
poprosedRepair Action
=

A list of most probable fail probable causes is shown


(max four messages)

Operation Failed
This NACK-message occurs in the following cases: Message cannot be performed, test
not supported, capacity restrictions, physical configuration cannot be performed, object
not locked.
Application Guidelines:

In phase 3 MO must be locked previous to the command execution

A50016-G5100-B333-04-7619

Id:0900d80580593f23

75

ACT

BS-4x / 82 II / 240 / 241 / 240XL commands

Example of Command Execution:


Perftest ACT:NAME=RACK:0/ACT:0;

STOPTEST ACT
STOPTEST ACT

NAME=RACK:0..7/ACT:0..0;

Command Tree:
MANAGED-ELEMENT h BSS-EQUIPMENT h BTSEP h RACK h ACT h
STOPTEST ACT
Applicability:
Phase 2 and Phase 3.
Visibility level: 1.
Command Description:
This command is used to stop a diagnostic previously started.
Long Names:
NAME

Address of the managed object

System Responses:
Operation Completed
Test has been stopped. The System Responses will not be addressed to the MOT but
to the object BTSEP.

Result TEST:
name =

TEST:<n>

testOutcome =

inconclusive

mOts =

It is the identifier of the hardware object under test.

testTermination =

Cancel

executedPhases
phaseId =
...
.

It represents the list of the executed test phases; the


list is not shown for test in the waiting list (queued).

failedPhases
phaseId =

It represents the list of the failed test phase;

phaseId =

additional information is provided for each phase.

....
skippedPhases
phaseId =
phaseId =

76

It represents the list of the skipped phases;the list is


not shown for test in the waiting list (queued).

Id:0900d80580593f23

A50016-G5100-B333-04-7619

BS-4x / 82 II / 240 / 241 / 240XL commands

ACT

Operation Failed
Test has not been stopped. This NACK-message can occur when the specified test is
not running or in case of test which cannot be stopped.
Application Guidelines:
None.
Example of Command Execution:
Stoptest ACT:NAME=RACK:0/ACT:0;

UNLOCK ACT
UNLOCK ACT

NAME=RACK:0..7/ACT:0..0;

Command Tree:
MANAGED-ELEMENT h BSS-EQUIPMENT h BTSEP h RACK h ACT h
UNLOCK ACT
Applicability:
Phase 2 and Phase 3.
Visibility level: 1.
Command Description:
This command changes the administrative state of ACT (Alarm Collection Terminal).
Long Names:
NAME

Address of the managed object

System Responses:
Operation Completed
The specified change of administrative state has been perfomed:
JOB: 192
PC Time&Date: 16:49:15 03/23/2005
NE Time&Date: 16:47:09 09/15/2004
USER NAME:

User_b

COMMAND:

Unlock ACT:NAME=RACK:0/ACT:0;

SW RELEASE:

01-04-17-01-26-51_05-02-23

COMMAND RESULT: Operation successful


administrativeState = Unlocked
END OF OUTPUT FOR JOB 192

A50016-G5100-B333-04-7619

Id:0900d80580593f23

77

ACT

BS-4x / 82 II / 240 / 241 / 240XL commands

CHANGED STATE EVENT REPORT:


This provides information about the administrative state, the operational state and the
availability status every time a state change occurs:
JOB: 193
PC Time&Date: 16:49:15 03/23/2005
NE Time&Date: 16:47:09 09/15/2004
USER NAME:

User_b

SW RELEASE:

01-04-17-01-26-51_05-02-23

COMMAND RESULT: Operation successful


CHANGED STATE EVENT REPORT:
NAME = RACK:0/ACT:0
Administrative State = UNLOCKED
Notification Identifier = 567
END OF OUTPUT FOR JOB 193
Operation Failed
The specified change of administrative state has not been performed.
Application Guidelines:
None.
Example of Command Execution:
Unlock ACT:NAME=RACK:0/ACT:0;

78

Id:0900d80580593f23

A50016-G5100-B333-04-7619

BS-4x / 82 II / 240 / 241 / 240XL commands

BATTERY

BATTERY
One backup battery system can be connected to the AC/DC sub-rack. The battery
system can consist of up to four batteries optionally housed in the battery sub-rack. The
DC and Battery Controller (DCBCTRL) installed in the AC/DC subrack is the supervision
unit which provides for the Batteries charging.

CREATE BATTERY
CREATE BATTERY

NAME=RACK:0..7/BATTERY:0..3;

Command Tree:
MANAGED-ELEMENT h BSS-EQUIPMENT h BTSEP h RACK h BATTERY h
CREATE BATTERY
Applicability:
Phase 2 and Phase 3.
Visibility level: 2.
Command Description:
This command adds the BATTERY (which provides battery backup) to the BTSE data
base.
Long Names:
NAME

Address of the managed object

System Responses:
Operation Completed
After command execution, a message of Changed Configuration Notification is displayed.
A further message indicates the result of the operation. An example of create command
is the following:
JOB: 21
PC Time&Date: 11:54:46 03/23/2005
NE Time&Date: 12:56:21 09/15/2004
USER NAME:

User_c

SW RELEASE:

01-04-17-01-26-51_05-02-23

COMMAND RESULT: Operation successful


ChangedConfigurationNotification:
name = RACK:0/BATTERY:0

A50016-G5100-B333-04-7619

Id:0900d80580593f25

79

BATTERY

BS-4x / 82 II / 240 / 241 / 240XL commands

ChangeInfo = created
END OF OUTPUT FOR JOB 21
JOB: 22
PC Time&Date: 11:54:47 03/23/2005
NE Time&Date: 12:56:22 09/15/2004
USER NAME:

User_c

COMMAND:

Create BATTERY:NAME=RACK:0/BATTERY:0;

SW RELEASE:

01-04-17-01-26-51_05-02-23

COMMAND RESULT: Operation successful


END OF OUTPUT FOR JOB 22
Operation Failed
The specified Object has not been created. In addition to the general NACK causes, a
specific NACK cause, which indicates that the command is inconsistent with the
physical configuration, is possible. An example is the following:
JOB: 23
PC Time&Date: 11:55:04 03/23/2005
NE Time&Date: 12:56:39 09/15/2004
USER NAME:

User_c

COMMAND:

Create BATTERY:NAME=RACK:0/BATTERY:0;

SW RELEASE:

01-04-17-01-26-51_05-02-23

COMMAND RESULT: OPERATION FAILED


MO already created (-159)
END OF OUTPUT FOR JOB 23
Application Guidelines:

80

The AC/DC is necessary for the charging and supervising of the battery backup
system

When a service environment (AC/DC + Battery Backup) is built on at BS60 sites,


after replacement of BS60 with BS-240 a special setting of the attribute "associatedString" in the command "CREATE ENVABTSE" for the corresponding site input
allows the operator to indicate that the support of emergency configuration is

Id:0900d80580593f25

A50016-G5100-B333-04-7619

BS-4x / 82 II / 240 / 241 / 240XL commands

BATTERY

required for battery backup unit system (Emergency Configuration after AC fault of
3rd party Service Rack)

The BATTERY can not be created for the BS-240 Compact Site as it is equipped in
the Battery Backup Rack and Energy Station Rack which are not supervised by the
SW. In the BS-240 implementation the switch into emergency configuration (due to
a battery discharge alarm) is triggered by an "ALARM STATUS" CAN bus message
that has been received from the CAN node of the AC/DC controller. In the BS-240
Compact Site the AC/DC alarm line for the AC/DC converter and for the battery must
be connected to a site input which is used as a trigger for the emergency configuration. A special setting of the attribute "associatedString" in the command "CREATE
ENVABTSE" for the corresponding site input allows the operator to indicate that the
support of emergency configuration is required for the 3rd party battery backup unit
system

The BATTERY can not be created for the BS-40II

Example of Command Execution:


Create BATTERY:NAME=RACK:0/BATTERY:0;

DELETE BATTERY
DELETE BATTERY

NAME=RACK:0..7/BATTERY:0..3;

Command Tree:
MANAGED-ELEMENT h BSS-EQUIPMENT h BTSEP h RACK h BATTERY h
DELETE BATTERY
Applicability:
Phase 2 and Phase 3.
Visibility level: 2.
Command Description:
This command deletes the BATTERY (which provides battery backup) from the BTSE
data base.
Long Names:
NAME

Address of the managed object

System Responses:
Operation Completed
After command execution, a message of Changed Configuration Notification is displayed. A further message indicates the result of the operation. An example of delete
command is the following:
JOB: 19
PC Time&Date: 11:54:44 03/23/2005
NE Time&Date: 12:56:19 09/15/2004

A50016-G5100-B333-04-7619

Id:0900d80580593f25

81

BATTERY

BS-4x / 82 II / 240 / 241 / 240XL commands

USER NAME:

User_c

SW RELEASE:

01-04-17-01-26-51_05-02-23

COMMAND RESULT: Operation successful


ChangedConfigurationNotification:
name = RACK:0/BATTERY:0
ChangeInfo = deleted
END OF OUTPUT FOR JOB 19
JOB: 20
PC Time&Date: 11:54:44 03/23/2005
NE Time&Date: 12:56:19 09/15/2004
USER NAME:

User_c

COMMAND:

Delete BATTERY:NAME=RACK:0/BATTERY:0;

SW RELEASE:

01-04-17-01-26-51_05-02-23

COMMAND RESULT: Operation successful


END OF OUTPUT FOR JOB 20
Operation Failed
The specified Object has not been deleted. Additionally to the general NACK causes, a
specific NACK cause, meaning that the command is inconsistent with physical configuration, is possible.
Application Guidelines:

BATTERY must be locked in phase 3 before deletion

The BATTERY can not be deleted for the BS-240 Compact Site as it is equipped in
the Battery Backup Rack and Energy Station Rack which are not supervised by the
SW

The BATTERY can not be deleted for the BS-40II

Example of Command Execution:


Delete BATTERY:NAME=RACK:0/BATTERY:0;

GET BATTERY
GET BATTERY

82

NAME=RACK:0..7/BATTERY:0..3 [,REQATTL=ALS, AST,


AVS, BATTCAP, OST, PRS, RELFUNCOBJ];

Id:0900d80580593f25

A50016-G5100-B333-04-7619

BS-4x / 82 II / 240 / 241 / 240XL commands

BATTERY

Command Tree:
MANAGED-ELEMENT h BSS-EQUIPMENT h BTSEP h RACK h BATTERY h
GET BATTERY
Applicability:
Phase 2 and Phase 3.
Visibility level: 0.
Command Description:
This command displays the attributes of the BATTERY.
Long Names:
NAME

Address of the managed object

REQATTL

Required attribute list

ALS

alarmStatus

AST

administrativeState

AVS

availabilityStatus

BATTCAP

batteryCapacity(*5Ah)

OST

operationalState

PRS

proceduralStatus

RELFUNCOBJ

relatedFuncObjects

System Responses:
Operation Completed
A message indicates the result of the operation. An example of get command is the following:
JOB: 5
PC Time&Date: 11:54:18 03/23/2005
NE Time&Date: 12:55:53 09/15/2004
USER NAME:

User_c

COMMAND:

Get BATTERY:NAME=RACK:0/BATTERY:0;

SW RELEASE:

01-04-17-01-26-51_05-02-23

COMMAND RESULT: Operation successful


alarmStatus = CLEARED
administrativeState = Unlocked
availabilityStatus = NULL
batteryCapacity(*5Ah) = 3
operationalState = ENABLED

A50016-G5100-B333-04-7619

Id:0900d80580593f25

83

BATTERY

BS-4x / 82 II / 240 / 241 / 240XL commands

proceduralStatus = NULL
relatedFuncObjects =
END OF OUTPUT FOR JOB 5
Operation Failed
The GET command has not been successfully executed. A general NACK will indicate
possible errors or a specific NACK strictly related to the single command is possible.
Application Guidelines:

The GET BATTERY command can not be issued for the BS-240 Compact Site as
the BATTERY is equipped in the Battery Backup Rack and Energy Station Rack
which are not supervised by the SW

The GET BATTERY command can not be issued for the BS-40II

Example of Command Execution:


Get BATTERY:NAME=RACK:0/BATTERY:0,REQATTL=ALS&AST&AVS&
BATTCAP&OST&PRS&RELFUNCOBJ;

GETTEST BATTERY
GETTEST BATTERY

NAME=RACK:0..7/BATTERY:0..3;

Command Tree:
MANAGED-ELEMENT h BSS-EQUIPMENT h BTSEP h RACK h BATTERY h
GETTEST BATTERY
Applicability:
Phase 2 and Phase 3.
Visibility level: 0.
Command Description:
This command displays the attributes of the BATTERY test.
Long Names:
NAME

Address of the managed object

REQATTL

Required attribute list

System Responses:
Operation Completed
A message indicates the result of the operation. An example of gettest command is the
following:
JOB: 14
PC Time&Date: 11:54:31 03/23/2005

84

Id:0900d80580593f25

A50016-G5100-B333-04-7619

BS-4x / 82 II / 240 / 241 / 240XL commands

BATTERY

NE Time&Date: 12:56:06 09/15/2004


USER NAME:

User_c

COMMAND:

Gettest BATTERY:NAME=RACK:0/BATTERY:0;

SW RELEASE:

01-04-17-01-26-51_05-02-23

COMMAND RESULT: Operation successful


MOT = RACK:0/BATTERY:0
testMonitor =
phaseId = PreliminaryTestsBattery
phaseStatus = Running
phaseId = CheckAlarmStatusBattery
phaseStatus = Waiting
phaseId = EndTestBattery
phaseStatus = Waiting
testOutcome = INCONCLUSIVE
testState = INITIALIZING
END OF OUTPUT FOR JOB 14
Operation Failed
The GET command has not been successfully executed. A general NACK will indicate
possible errors or a specific NACK strictly related to the single command is possible.
testMonitor
phaseId =
phaseStatus =

it is a list of all test phases related to the


selected object; for each phase the
related phaseStatus is provided (Passed,
Failed, Running or Waiting).

phaseId =
phaseStatus =
...
...
testOutcome

It represents the test result: it can be


Inconclusive (if the phases already
executed were successful) or Fail (if at
least one of the executed phases failed).

testState = Testing

It can assume one of the following values:


not_initialized, idle, initializing, suspended, testing, terminating and disabled.

Application Guidelines:
None.

A50016-G5100-B333-04-7619

Id:0900d80580593f25

85

BATTERY

BS-4x / 82 II / 240 / 241 / 240XL commands

Example of Command Execution:


Gettest BATTERY:NAME=RACK:0/BATTERY:0;

LOCK BATTERY
LOCK BATTERY

NAME=RACK:0..7/BATTERY:0..3;

Command Tree:
MANAGED-ELEMENT h BSS-EQUIPMENT h BTSEP h RACK h BATTERY h
LOCK BATTERY
Applicability:
Phase 2 and Phase 3.
Visibility level: 1.
Command Description:
This command changes the administrative state of the BATTERY (which provides
battery backup).
Long Names:
NAME

Address of the managed object

System Responses:
Operation Completed
The specified change of administrative state has been perfomed:
JOB: 6
PC Time&Date: 11:54:22 03/23/2005
NE Time&Date: 12:55:57 09/15/2004
USER NAME:

User_c

COMMAND:

Lock BATTERY:NAME=RACK:0/BATTERY:0;

SW RELEASE:

01-04-17-01-26-51_05-02-23

COMMAND RESULT: Operation successful


administrativeState = Locked
END OF OUTPUT FOR JOB 6

CHANGED STATE EVENT REPORT:


This provides information about the administrative state, the operational state and the
availability status every time a state change occurs:

86

Id:0900d80580593f25

A50016-G5100-B333-04-7619

BS-4x / 82 II / 240 / 241 / 240XL commands

BATTERY

JOB: 7
PC Time&Date: 11:54:22 03/23/2005
NE Time&Date: 12:55:57 09/15/2004
USER NAME:

User_c

SW RELEASE:

01-04-17-01-26-51_05-02-23

COMMAND RESULT: Operation successful


CHANGED STATE EVENT REPORT:
NAME = RACK:0/BATTERY:0
Administrative State = LOCKED
Notification Identifier = 263
END OF OUTPUT FOR JOB 7
Operation Failed
The specified change of administrative state has not been performed (e.g. the object is
redundant and its spare copy is disabled or already locked, a subordinate resource
cannot go into disabled state with "dependency" availability status).
Application Guidelines:

The BATTERY can not be locked for the BS-240 Compact Site as it is equipped in
the Battery Backup Rack and Energy Station Rack which are not supervised by the
SW

The BATTERY can not be locked for the BS-40II

Example of Command Execution:


Lock BATTERY:NAME=RACK:0/BATTERY:0;

PERFTEST BATTERY
PERFTEST BATTERY

NAME=RACK:0..7/BATTERY:0..3;

Command Tree:
MANAGED-ELEMENT h BSS-EQUIPMENT h BTSEP h RACK h BATTERY h
PERFTEST BATTERY
Applicability:
Phase 2 and Phase 3.
Visibility level: 1.

A50016-G5100-B333-04-7619

Id:0900d80580593f25

87

BATTERY

BS-4x / 82 II / 240 / 241 / 240XL commands

Command Description:
This command requests the execution of a test performed by the BATTERY (which
provides battery backup).
Long Names:
NAME

Address of the managed object

System Responses:
Operation Completed
Test configuration has been set and the specified test has been started. The System
response will not be addressed to the MOT but to the object BTSEP.
JOB: 9
PC Time&Date: 11:54:26 03/23/2005
NE Time&Date: 12:56:01 09/15/2004
USER NAME:

User_c

COMMAND:

Perftest BATTERY:NAME=RACK:0/BATTERY:0;

SW RELEASE:

01-04-17-01-26-51_05-02-23

COMMAND RESULT: Operation successful


MOT = RACK:0/BATTERY:0
tO = BTSETEST:2
END OF OUTPUT FOR JOB 9
JOB: 10
PC Time&Date: 11:54:26 03/23/2005
NE Time&Date: 12:56:01 09/15/2004
USER NAME:

User_c

SW RELEASE:

01-04-17-01-26-51_05-02-23

COMMAND RESULT: Operation successful


ChangedConfigurationNotification:
name = BTSETEST:2
ChangeInfo = created

88

Id:0900d80580593f25

A50016-G5100-B333-04-7619

BS-4x / 82 II / 240 / 241 / 240XL commands

BATTERY

END OF OUTPUT FOR JOB 10


JOB: 11
PC Time&Date: 11:54:26 03/23/2005
NE Time&Date: 12:56:01 09/15/2004
USER NAME:

User_c

SW RELEASE:

01-04-17-01-26-51_05-02-23

COMMAND RESULT: Operation successful


CHANGED STATE EVENT REPORT:
NAME = RACK:0/BATTERY:0
Operational State = ENABLED
Availability Status = NULL_value
Notification Identifier = 267
END OF OUTPUT FOR JOB 11
JOB: 12
PC Time&Date: 11:54:26 03/23/2005
NE Time&Date: 12:56:01 09/15/2004
USER NAME:

User_c

SW RELEASE:

01-04-17-01-26-51_05-02-23

COMMAND RESULT: Operation successful


Test Report:
name = BTSETEST:2
testOutcome = PASSED
testTermination = Normal
MOT = RACK:0/BATTERY:0
executedPhases =
PreliminaryTestsBattery
CheckAlarmStatusBattery
EndTestBattery

A50016-G5100-B333-04-7619

Id:0900d80580593f25

89

BATTERY

BS-4x / 82 II / 240 / 241 / 240XL commands

END OF OUTPUT FOR JOB 12


JOB: 13
PC Time&Date: 11:54:26 03/23/2005
NE Time&Date: 12:56:01 09/15/2004
USER NAME:

User_c

SW RELEASE:

01-04-17-01-26-51_05-02-23

COMMAND RESULT: Operation successful


ChangedConfigurationNotification:
name = BTSETEST:2
ChangeInfo = deleted
END OF OUTPUT FOR JOB 13
The test results will be displayed at the end of the test phases.
Result TEST:
name =

TEST:<n>

testOutcome =

This field represents the test result; one of the following values can be displayed:
Pass

all the test phases are successfully


performed.

Inconclusive

the test is aborted by the system or


the test is terminated by the operator.

Fail

if at least one of the executed phases


fail.

mOts =

It is the identifier of the hardware object under test.

testTermination =

It specifies how the test is terminated, it can assume


the following values:
Normal

all the test phases are performed.

Abort

the test is aborted by system.

Cancel

the test is terminated by operator.

executedPhases
phaseId =
additionalWords =
....

90

It represents the list of the executed test phases (in


case of successful test result, all the test phases will
be listed).

Id:0900d80580593f25

A50016-G5100-B333-04-7619

BS-4x / 82 II / 240 / 241 / 240XL commands

BATTERY

failedPhases
phaseId =

It represents the list of the failed test phase; additional information is provided for each phase.

phaseId =
....
skippedPhases
phaseId =

It represents the list of the skipped phases; they are


displayed only for test stopped during it execution.

phaseId =
....
poprosedRepair Action
=

A list of most probable fail probable causes is shown


(max four messages)

Operation Failed
This NACK-message occurs in the following cases: Message cannot be performed, test
not supported, capacity restrictions, physical configuration cannot be performed, object
not locked.
Application Guidelines:

In phase 3 MO must be locked previous to the command execution

Example of Command Execution:


Perftest BATTERY:NAME=RACK:0/BATTERY:0;

STOPTEST BATTERY
STOPTEST BATTERY

NAME=RACK:0..7/BATTERY:0..3;

Command Tree:
MANAGED-ELEMENT h BSS-EQUIPMENT h BTSEP h RACK h BATTERY h
STOPTEST BATTERY
Applicability:
Phase 2 and Phase 3.
Visibility level: 1.
Command Description:
This command is used to stop a diagnostic previously started.
Long Names:
NAME

Address of the managed object

System Responses:
Operation Completed
Test has been stopped. The System Responses will not be addressed to the MOT but
to the object BTSEP.

A50016-G5100-B333-04-7619

Id:0900d80580593f25

91

BATTERY

BS-4x / 82 II / 240 / 241 / 240XL commands

Result TEST:
name =

TEST:<n>

testOutcome =

inconclusive

mOts =

It is the identifier of the hardware object under test.

testTermination =

Cancel

executedPhases
phaseId =

It represents the list of the executed test phases; the


list is not shown for test in the waiting list (queued).

...
.
failedPhases
phaseId =

It represents the list of the failed test phase;

phaseId =

additional information is provided for each phase.

....
skippedPhases
phaseId =

It represents the list of the skipped phases;the list is


not shown for test in the waiting list (queued).

phaseId =
Operation Failed

Test has not been stopped. This NACK-message can occur when the specified test is
not running or in case of test which cannot be stopped.
Application Guidelines:
None
Example of Command Execution:
Stoptest BATTER.Y:NAME=RACK:0/BATTERY:0;

UNLOCK BATTERY
UNLOCK BATTERY

NAME=RACK:0..7/BATTERY:0..3;

Command Tree:
MANAGED-ELEMENT h BSS-EQUIPMENT h BTSEP h RACK h BATTERY h
UNLOCK BATTERY
Applicability:
Phase 2 and Phase 3.
Visibility level: 1.
Command Description:
This command changes the administrative state of the BATTERY (which provides
battery backup).

92

Id:0900d80580593f25

A50016-G5100-B333-04-7619

BS-4x / 82 II / 240 / 241 / 240XL commands

BATTERY

Long Names:
NAME

Address of the managed object

System Responses:
Operation Completed
The specified change of administrative state has been perfomed:
JOB: 15
PC Time&Date: 11:54:35 03/23/2005
NE Time&Date: 12:56:10 09/15/2004
USER NAME:

User_c

COMMAND:

Unlock BATTERY:NAME=RACK:0/BATTERY:0;

SW RELEASE:

01-04-17-01-26-51_05-02-23

COMMAND RESULT: Operation successful


administrativeState = Unlocked
END OF OUTPUT FOR JOB 15

CHANGED STATE EVENT REPORT:


This provides information about the administrative state, the operational state and the
availability status every time a state change occurs:
JOB: 16
PC Time&Date: 11:54:35 03/23/2005
NE Time&Date: 12:56:10 09/15/2004
USER NAME:

User_c

SW RELEASE:

01-04-17-01-26-51_05-02-23

COMMAND RESULT: Operation successful


CHANGED STATE EVENT REPORT:
NAME = RACK:0/BATTERY:0
Administrative State = UNLOCKED
Notification Identifier = 268

A50016-G5100-B333-04-7619

Id:0900d80580593f25

93

BATTERY

BS-4x / 82 II / 240 / 241 / 240XL commands

END OF OUTPUT FOR JOB 16


Operation Failed
The specified change of administrative state has not been performed.
Application Guidelines:

The BATTERY can not be unlocked for the BS-240 Compact Site as it is equipped
in the Battery Backup Rack and Energy Station Rack which are not supervised by
the SW

The BATTERY can not be unlocked for the BS-40II

Example of Command Execution:


Unlock BATTERY:NAME=RACK:0/BATTERY:0;

94

Id:0900d80580593f25

A50016-G5100-B333-04-7619

BS-4x / 82 II / 240 / 241 / 240XL commands

BCOM

BCOM
The BCOM (Combining Module) is an equipment object that represents the combining
module supporting up to 6 TRX, all within the same frequency band. The BCOM has no
CAN bus interface and therefore cannot provide the remote inventory data onboard.
New BCOM element shall be handled via IDF editor from LMT. No ACT-C is supported.
MDUX (a small BCOM 6:6) and HYBRID6 can replace FDUAMCOs. MDUX can fit into
2 adjacent ACOM slots of BTSplus mainline rack. If more than 6 transceivers are
required, the HYBRID6 module, containing 6 hybrids and isolators, has to be additionally equipped. This module fits either in a BCOM slot (along with a MDUX) or in an
ACOM- respectively MUCO-slot of the BTSplus mainline rack.
The alarm interface of the MDUX is identical and fully compatible to the BCOM, while
the HYBRID6 is a completely passive module with only RF interfaces. It is therefore not
visible for the software.
The 6:6 combining of the MDUX allows single rack cell configurations which cannot be
supported with the existing combining equipment. With 2 MDUX equipped in a single
BS240 II rack a 2/2/2 dual band configuration becomes possible.
All inventory units of the optional Siemens Service Rack are nob_RIUs which have to be
registered via LMT and IDF editor.

g BCOM command is valid only for BS240 and BS240XL.


The configurations BCOM (MDUX) + HYBRID6 +COAMCO are possible.
The maximum number of carrier unit ports, which are connected to the RX outputs of an
MDUX submodule is:

4 for MDUX only equipped

8 for MDUX and COAMCO equipped.

The maximum number of carrier unit ports which are either directly or via HYBRID6 connected to the TX input of an MDUX submodule is:

1 for MDUX without HYBRID6 equipped

2 for MDUX with HYBRID6 equipped

4 for MDUX with HYBRID6 and COAMCO equipped

CREATE BCOM
CREATE BCOM

NAME=RACK:0..7/BCOM:0..1 [,ANT<x>CELLNO=]
[,ANT<x>SCNRX=] ,ACONN= [,FBAND=] [,BCOMTYPE=];

Command Tree:
MANAGED-ELEMENT h BSS-EQUIPMENT h BTSEP h RACK h BCOM h
CREATE BCOM

A50016-G5100-B333-04-7619

Id:0900d80580593f27

95

BCOM

BS-4x / 82 II / 240 / 241 / 240XL commands

Applicability:
Phase 2 and Phase 3.
Visibility level: 2.
Command Description:
This command is used to create the instances 0 and 1 of BCOM object.
In this CREATE command cell number, an alarm connector or frequency band of Bcom
can be specified.
Furthermore SetWiringRx BCOM and SetWiringTx BCOM commands have to be used
to specify the wiring data. Alarm connector parameter is mandatory at the creation of
BCOM.
Long Names:
NAME

Address of the managed object

ANT<x>CELLNO
ANT<x>SCNRX

ant<x>CellNumber
ant<x>SecondCellNumberRx

ACONN

alarmConnector

FBAND

frequencyBand

BCOMTYPE

bcomType

System Responses:
Operation Completed
After command execution, a message of Changed Configuration Notification is displayed. A further message indicates the result of the operation. An example of create
command is the following:
Create BCOM:1
JOB: 301
PC Time&Date: 27.02.2008 12:47:48 +01:00
NE Time&Date: 01.01.1990 00:12:06 +00:00
USER NAME:

User_d

SW RELEASE:

01-04-19-01-06-00_08-02-13

COMMAND RESULT: Operation successful


ChangedConfigurationNotification:
name = RACK:0/BCOM:1
ChangeInfo = created
END OF OUTPUT FOR JOB 301

96

Id:0900d80580593f27

A50016-G5100-B333-04-7619

BS-4x / 82 II / 240 / 241 / 240XL commands

BCOM

Binary Command

02 00 01 01

Binary Response

0d 00 80 00 02 12 00 7f ab 25 00 01 1f 01 00

JOB: 302
PC Time&Date: 27.02.2008 12:47:48 +01:00
NE Time&Date: 01.01.1990 00:12:06 +00:00
USER NAME:

User_d

COMMAND:

Create

BCOM:NAME=RACK:0/BCOM:1,ACONN=ENVA8,BCOMTYPE=SixToSixMDUX,FBAND=Gsm850,ANT0CELLNO=1,ANT0SCNRX=1;
SW RELEASE:

01-04-19-01-06-00_08-02-13

COMMAND RESULT: Operation successful

ant0CellNumber = 1
ant0SecondCellNumberRx = 1
alarmConnector = ENVA8
frequencyBand = Gsm850
bcomType = SixToSixMDUX
END OF OUTPUT FOR JOB 302

A50016-G5100-B333-04-7619

Id:0900d80580593f27

97

BCOM

BS-4x / 82 II / 240 / 241 / 240XL commands

Binary Command

19 00 80 ff 12 02 81 a9 ab 25 00 01 46 01 01 4c 01 01 1e 01
08 71 01 00 70 01 02

Binary Response

19 00 80 00 02 12 01 aa ab 25 00 01 46 01 01 4c 01 01 1e 01
08 71 01 00 70 01 02
Operation Failed
JOB: 287
PC Time&Date: 27.02.2008 12:44:29 +01:00
NE Time&Date: 01.01.1990 00:08:47 +00:00
USER NAME:

User_d

COMMAND:
Create
BCOM:NAME=RACK:0/BCOM:0,ACONN=ENVA3,ANT0CELLNO=0;
SW RELEASE:

01-04-19-01-06-00_08-02-13

COMMAND RESULT: Operation failed

ant0CellNumber = 0
alarmConnector = ENVA3
Message cannot be performed (-17)
END OF OUTPUT FOR JOB 287

Binary Command

10 00 80 ff 12 02 81 a9 ab 25 00 00 46 01 00 1e 01 03

98

Id:0900d80580593f27

A50016-G5100-B333-04-7619

BS-4x / 82 II / 240 / 241 / 240XL commands

BCOM

Binary Response

11 00 80 00 02 12 01 ab ab 25 00 00 46 01 00 1e 01 03 11
Application Guidelines:
After the CREATE command, commands SetWiringRx BCOM and SetWiringTx BCOM
must be issued to specify antenna combiner wiring.
Creation of BCOM:i is rejected if DUAMCO:(2i) or DUAMCO:(2i+1) is created.
The creation of a BCOM instance is rejected if a DUVSWR or DULNA instance has been
created for at least one of the assigned ACOM slots.
The creation of a BCOM instance is rejected if the ACTC alarm connector is already
used by an ENVABTSE instance.
The creation of a BCOM instance shall be rejected if the ACTC alarm connector is used
by already existing BCOM instance.
SixToSixMDUX, TwelveToSixMDUX, TwelveToSixCOAMO are allowed wiring
combinations for BcomType attribute in the CREATE BCOM command on BTSPlus
Mainline, SixtoSix and TwelvetoSix options in the CREATE BCOM command are
rejected by BTS software.
Example of Command Execution:
Create BCOM:NAME=RACK:0/BCOM:1, ANT0CELLNO=0, ACONN=ENVA0,
FBAND=GSM900, BCOMTYPE=NotSet;

DELETE BCOM
DELETE BCOM

NAME=RACK:0..7/BCOM:0..1;

Command Tree:
MANAGED-ELEMENT h BSS-EQUIPMENT h BTSEP h RACK h BCOM h
DELETE BCOM
Applicability:
Phase 2 and Phase 3.
Visibility level: 2.
Command Description:
This command is used to delete BCOM.
Long Names:
NAME

Address of the managed object

System Responses:
Operation Completed
After command execution, a message of Changed Configuration Notification is displayed. A further message indicates the result of the operation. An example of delete
command is the following:

A50016-G5100-B333-04-7619

Id:0900d80580593f27

99

BCOM

BS-4x / 82 II / 240 / 241 / 240XL commands

Delete BCOM:1
JOB: 6179
PC Time&Date: 31.01.2007 16:25:51 +01:00
NE Time&Date: 31.01.2007 17:25:20 +01:00
USER NAME:

User_d

COMMAND:

Delete BCOM:NAME=RACK:0/BCOM:1;

SW RELEASE:

01-04-18-06-13-04_07-01-26

COMMAND RESULT: Operation successful

END OF OUTPUT FOR JOB 6179


Operation Failed
None.
Application Guidelines:
None.
Example of Command Execution:
Delete BCOM:NAME=RACK:0/BCOM:1;

GET BCOM
GET BCOM

NAME=RACK:0..7/BCOM:0..1 [,REQATTL=ALS, AST, AVS,


OST, PRS, RELFUNCOBJ, ANT<x>CELLNO,
ANT<x>SCNRX, ACONN, FBAND, BCOMTYPE];

Command Tree:
MANAGED-ELEMENT h BSS-EQUIPMENT h BTSEP h RACK h BCOM h
GET BCOM
Applicability:
Phase 2 and Phase 3.
Visibility level: 0.
Command Description:
This command displays the attributes of the BCOM except the wiring data attributes.
Long Names:

100

NAME

Address of the managed object

REQATTL

Required attribute list

Id:0900d80580593f27

A50016-G5100-B333-04-7619

BS-4x / 82 II / 240 / 241 / 240XL commands

BCOM

ALS

alarmStatus

AST

administrativeState

AVS

availabilityStatus

OST

operationalState

PRS

proceduralStatus

RELFUNCOBJ

relatedFuncObjects

ANT<x>CELLNO
ANT<x>SCNRX

ant<x>CellNumber
ant<x>SecondCellNumberRx

ACONN

alarmConnector

FBAND

frequencyBand

BCOMTYPE

bcomType

System Responses:
Operation Completed
A message indicates the result of the operation. An example of get command is the following:
JOB: 26
PC Time&Date: 12:03:04 03/24/2005
NE Time&Date: 00:02:31 11/29/2004
USER NAME: User_d
COMMAND: Get BCOM:NAME=RACK:0/BCOM:0;
SW RELEASE: 01-04-18-01- 26-51_05-02-23
COMMAND RESULT: Operation successful
alarmStatus = CRITICAL
administrativeState = Unlocked
availabilityStatus = Failed
ant<x>CellNumber = 2
ant<x>SecondCellNumberRx = 2
aconn=ENVA0
frequencyBand = Gsm900
relatedFuncObjects =
operationalState = DISABLED
proceduralStatus = NULL
END OF OUTPUT FOR JOB 26
Operation Failed

A50016-G5100-B333-04-7619

Id:0900d80580593f27

101

BCOM

BS-4x / 82 II / 240 / 241 / 240XL commands

The GET command has not been successfully executed. A general NACK will indicate
possible errors or a specific NACK strictly related to the single command is possible.
Application Guidelines:
None.
Example of Command Execution:
BCOM:NAME=RACK:0/BCOM:0,REQATTL=ALS&AST&AVS&ANT<x>CELLNO&ANT
<x>SCNRX&OST&PRS&RELFUNCOBJ&ACONN&FBAND&BCOMTYPE;

GETRELATIONSHIP BCOM
GETRELATIONSHIP
BCOM

NAME=RACK:0..7/BCOM:0..1;

Command Tree:
MANAGED-ELEMENT h BSS-EQUIPMENT h BTSEP h RACK h BCOM h
GETRELATIONSHIP BCOM
Applicability:
Phase 2 and Phase 3.
Visibility level: 0.
Command Description:
This command is used to retrieve the functional relationship information for the selected
HMO (Hardwar Managed Object); the relationship information consists of all FMOs
(Functional Managed Object) using the HMO service.
Long Names:
NAME

Address of the managed object

REQATTL

Required attribute list

System Responses:
Operation Completed
A message indicates the result of the operation. An example of getrelationship
command is the following:
JOB: 1227221
PC Time&Date: 01/29/2007 14:44:27 +01:00
NE Time&Date: 01/29/2007 15:44:11 +01:00
USER NAME:

User_d

COMMAND:

Getrelationship BCOM:NAME=RACK:0/BCOM:0;

SW RELEASE:

01-04-18-06-13-04_07-01-26

COMMAND RESULT: Operation successful

102

Id:0900d80580593f27

A50016-G5100-B333-04-7619

BS-4x / 82 II / 240 / 241 / 240XL commands

BCOM

relatedFuncObjects =
FMO = BTS:0/TRX:4
FMO = BTS:0/TRX:6
FMO = BTS:0/TRX:8
FMO = BTS:0/TRX:10
FMO = BTS:0/TRX:9
FMO = BTS:0/TRX:2

END OF OUTPUT FOR JOB 1227221

JOB: 1227222
PC Time&Date: 01/29/2007 14:44:27 +01:00
NE Time&Date: 01/29/2007 15:44:11 +01:00
USER NAME:

User_d

COMMAND:

Getrelationship BCOM:NAME=RACK:0/BCOM:1;

SW RELEASE:

01-04-18-06-13-04_07-01-26

COMMAND RESULT: Operation successful

relatedFuncObjects =
FMO = BTS:0/TRX:1
FMO = BTS:0/TRX:3
FMO = BTS:0/TRX:5
FMO = BTS:0/TRX:7
FMO = BTS:0/TRX:11
FMO = BTS:0/TRX:0
Operation Failed
None.
Application Guidelines:
None.
Example of Command Execution:
Getrelationship BCOM:NAME=RACK:0/BCOM:0;

A50016-G5100-B333-04-7619

Id:0900d80580593f27

103

BCOM

BS-4x / 82 II / 240 / 241 / 240XL commands

GETTEST BCOM
GETTEST BCOM

NAME=RACK:0..7/BCOM:0..1;

Command Tree:
MANAGED-ELEMENT h BSS-EQUIPMENT h BTSEP h RACK h BCOM h
GETTEST BCOM
Applicability:
Phase 2 and Phase 3.
Visibility level: 0.
Command Description:
This command displays the attributes of the BCOM test.
Long Names:
NAME

Address of the managed object

REQATTL

Required attribute list

System Responses:
Operation Completed
A message indicates the result of the operation. An example of gettest command is the
following:
JOB: 25
PC Time&Date: 12:01:44 03/24/2005
NE Time&Date: 00:01:11 11/29/2004
USER NAME:

User_d

COMMAND:

Gettest BCOM:NAME=RACK:0/BCOM:0;

SW RELEASE:

01-04-17-06-26-51_05-02-23

COMMAND RESULT: Operation successful


MOT = RACK:0/BCOM:0
testMonitor =
phaseId = PreliminaryTestsBcom
phaseStatus = Running
phaseId = CheckAlarmStatusBcom
phaseStatus = Waiting
phaseId = EndTestBcom
phaseStatus = Waiting
testOutcome = INCONCLUSIVE
testState = INITIALIZING

104

Id:0900d80580593f27

A50016-G5100-B333-04-7619

BS-4x / 82 II / 240 / 241 / 240XL commands

BCOM

END OF OUTPUT FOR JOB 25


Operation Failed
The GET command has not been successfully executed. A general NACK will indicate
possible errors or a specific NACK strictly related to the single command is possible.
testMonitor
phaseId =
phaseStatus =

it is a list of all test phases related to the


selected object; for each phase the
related phaseStatus is provided (Passed,
Failed, Running or Waiting).

phaseId =
phaseStatus =
...
...
testOutcome

It represents the test result: it can be


Inconclusive (if the phases already
executed were successful) or Fail (if at
least one of the executed phases failed).

testState = Testing

It can assume one of the following values:


not_initialized, idle, initializing, suspended, testing, terminating and disabled.

Application Guidelines:
None.
Example of Command Execution:
Gettest BCOM:NAME=RACK:0/BCOM:0,REQATTL=MORT&TESTMON&TESTOUT&
TESTST;

GETWIRINGRX BCOM
GETWIRINGRX BCOM NAME=RACK:0..7/BCOM:0..1 ,REQATTL=ANT<x>WDRX;
Command Tree:
MANAGED-ELEMENT h BSS-EQUIPMENT h BTSEP h RACK h BCOM h
GETWIRINGRX BCOM
Applicability:
Phase 2 and Phase 3.
Visibility level: 0.
Command Description:
This command displays the wiring data attributes of the BCOM for RX path.
It is applicable only on: BS240, BS240II, BS240XL, BS240XLII, BS241, BS241 II.

A50016-G5100-B333-04-7619

Id:0900d80580593f27

105

BCOM

BS-4x / 82 II / 240 / 241 / 240XL commands

Long Names:
NAME

Address of the managed object

REQATTL

Required attribute list

ANT<x>WDRX

ant<x>WiringDataRx

System Responses:
Operation Completed
A message indicates the result of the operation. An example of getWiringRx command
is the following:
********** Message 60 **********
JOB: 60
PC Time&Date: 17.12.2007 10:20:51 +01:00
NE Time&Date: 01.01.1990 00:07:40 +00:00
USER NAME: User_d
COMMAND: GetWiringRx
BCOM:NAME=RACK:0/BCOM:0,REQATTL=ANT0WDRX&ANT1WDRX&ANT2WDRX
&ANT3WDRX&ANT4WDRX&ANT5WDRX;
SW RELEASE: 01-04-18-01-18-01_07-12-14
COMMAND RESULT:Operation successful
ant0WiringDataRx = CU0N & CU1N & CU2N & CU3N & FCUMAIN5N & FCUMAIN5N1
& FCUMAIN6N & FCUMAIN6N1
ant1WiringDataRx = NULL
ant2WiringDataRx = NULL
ant3WiringDataRx = NULL
ant4WiringDataRx = NULL
ant5WiringDataRx = NULL
END OF OUTPUT FOR JOB 60
Operation Failed
The GETWIRINGRX command has not been successfully executed. A general NACK
will indicate possible errors or a specific NACK strictly related to the single command is
possible.
Application Guidelines:
None.
Example of Command Execution:
GetWiringRxBCOM:NAME=RACK:0/BCOM:0,REQATTL=
ANT0WDRX&ANT1WDRX&ANT2WDRX&ANT3WDRX&ANT4WDRX&ANT5WDRX;

106

Id:0900d80580593f27

A50016-G5100-B333-04-7619

BS-4x / 82 II / 240 / 241 / 240XL commands

BCOM

GETWIRINGTX BCOM
GETWIRINGTX BCOM

NAME=RACK:0..7/BCOM:0..1 ,REQATTL=ANT<x>WDTX;

Command Tree:
MANAGED-ELEMENT h BSS-EQUIPMENT h BTSEP h RACK h BCOM h
GETWIRINGTX BCOM
Applicability:
Phase 2 and Phase 3.
Visibility level: 0.
Command Description:
This command displays the wiring data attributes of the BCOM for TX path.
It is applicable only on: BS240, BS240II, BS240XL, BS240XLII, BS241, BS241 II.
Long Names:
NAME

Address of the managed object

REQATTL

Required attribute list

ANT<x>WDTX

ant<x>WiringDataTx

System Responses:
Operation Completed
A message indicates the result of the operation. An example of getWiringTx command
is the following:
********** Message 61 **********
JOB: 61
PC Time&Date: 17.12.2007 10:20:59 +01:00
NE Time&Date: 01.01.1990 00:07:48 +00:00
USER NAME: User_d
COMMAND: GetWiringTx
BCOM:NAME=RACK:0/BCOM:0,REQATTL=ANT0WDTX&ANT1WDTX&ANT2WDTX
&ANT3WDTX&ANT4WDTX&ANT5WDTX;
SW RELEASE: 01-04-18-01-18-01_07-12-14
COMMAND RESULT:Operation successful
ant0WiringDataTx = CU0 & CU1 & CU2 & CU3
ant1WiringDataTx = NULL
ant2WiringDataTx = NULL

A50016-G5100-B333-04-7619

Id:0900d80580593f27

107

BCOM

BS-4x / 82 II / 240 / 241 / 240XL commands

ant3WiringDataTx = NULL
ant4WiringDataTx = NULL
ant5WiringDataTx = NULL
END OF OUTPUT FOR JOB 61
Operation Failed
The GETWIRINGTX command has not been successfully executed. A general NACK
will indicate possible errors or a specific NACK strictly related to the single command is
possible.
Application Guidelines:
None.
Example of Command Execution:
GetWiringTx
BCOM:NAME=RACK:0/BCOM:0,REQATTL=ANT0WDTX&ANT1WDTX&ANT2WDTX
&ANT3WDTX&ANT4WDTX&ANT5WDTX;

LOCK BCOM
LOCK BCOM

NAME=RACK:0..7/BCOM:0..1;

Command Tree:
MANAGED-ELEMENT h BSS-EQUIPMENT h BTSEP h RACK h BCOM h
LOCK BCOM
Applicability:
Phase 2 and Phase 3.
Visibility level: 1.
Command Description:
This command changes the administrative state of the BCOM.
Long Names:
NAME

Address of the managed object

System Responses:
Operation Completed
The specified change of administrative state has been perfomed:
JOB: 27
PC Time&Date: 12:03:17 03/24/2005
NE Time&Date: 00:02:44 11/29/2004
USER NAME:

108

User_d

Id:0900d80580593f27

A50016-G5100-B333-04-7619

BS-4x / 82 II / 240 / 241 / 240XL commands

COMMAND:
SW RELEASE:

BCOM

Lock BCOM:NAME=RACK:0/BCOM:0;
01-04-17-06-26-51_05-02-23

COMMAND RESULT: Operation successful


administrativeState = Locked
END OF OUTPUT FOR JOB 27

CHANGED STATE EVENT REPORT:


This provides information about the administrative state, the operational state and the
availability status every time a state change occurs:
JOB: 28
PC Time&Date: 12:03:17 03/24/2005
NE Time&Date: 00:02:44 11/29/2004
USER NAME:

User_d

SW RELEASE:

01-04-17-06-26-51_05-02-23

COMMAND RESULT: Operation successful


CHANGED STATE EVENT REPORT:
NAME = RACK:0/BCOM:0
Administrative State = LOCKED
Notification Identifier = 22
END OF OUTPUT FOR JOB 28
Operation Failed
The specified change of administrative state has not been performed (e.g. the object is
redundant and its spare copy is disabled or already locked, a subordinate resource
cannot go into disabled state with "dependency" availability status).
Application Guidelines:
None.
Example of Command Execution:
Lock BCOM:NAME=RACK:0/BCOM:0;

A50016-G5100-B333-04-7619

Id:0900d80580593f27

109

BCOM

BS-4x / 82 II / 240 / 241 / 240XL commands

PERFTEST BCOM
PERFTEST BCOM

NAME=RACK:0..7/BCOM:0..1;

Command Tree:
MANAGED-ELEMENT h BSS-EQUIPMENT h BTSEP h RACK h BCOM h
PERFTEST BCOM
Applicability:
Phase 2 and Phase 3.
Visibility level: 1.
Command Description:
This command is used to start an asynchronous test in BCOM.
Long Names:
NAME

Address of the managed object

System Responses:
Operation Completed
Test configuration has been set and the specified test has been started. The System
response will not be addressed to the MOT but to the object.
JOB: 30
PC Time&Date: 12:03:25 03/24/2005
NE Time&Date: 00:02:52 11/29/2004
USER NAME:

User_d

COMMAND:

Perftest BCOM:NAME=RACK:0/BCOM:0;

SW RELEASE:

01-04-17-06-26-51_05-02-23

COMMAND RESULT: Operation successful


MOT = RACK:0/BCOM:0
tO = BTSETEST:1
END OF OUTPUT FOR JOB 30
JOB: 31
PC Time&Date: 12:03:25 03/24/2005
NE Time&Date: 00:02:52 11/29/2004
USER NAME:

110

User_d

Id:0900d80580593f27

A50016-G5100-B333-04-7619

BS-4x / 82 II / 240 / 241 / 240XL commands

SW RELEASE:

BCOM

01-04-17-06-26-51_05-02-23

COMMAND RESULT: Operation successful


ChangedConfigurationNotification:
name = BTSETEST:1
ChangeInfo = created
END OF OUTPUT FOR JOB 31
JOB: 32
PC Time&Date: 12:03:25 03/24/2005
NE Time&Date: 00:02:52 11/29/2004
USER NAME:

User_d

SW RELEASE:

01-04-17-06-26-51_05-02-23

COMMAND RESULT: Operation successful


CHANGED STATE EVENT REPORT:
NAME = RACK:0/BCOM:0
Availability Status = Failed
Notification Identifier = 27
END OF OUTPUT FOR JOB 32
JOB: 33
PC Time&Date: 12:03:25 03/24/2005
NE Time&Date: 00:02:52 11/29/2004
USER NAME:

User_d

SW RELEASE:

01-04-17-06-26-51_05-02-23

COMMAND RESULT: Operation successful


Test Report:
name = BTSETEST:1
testOutcome = FAILED

A50016-G5100-B333-04-7619

Id:0900d80580593f27

111

BCOM

BS-4x / 82 II / 240 / 241 / 240XL commands

testTermination = Normal
MOT = RACK:0/BCOM:0
executedPhases =
PreliminaryTestsBcom
EndTestBcom
failedPhases =
phaseId = CheckAlarmStatusBcom
additionalWords =
H`0001
H`0000
H`0000
H`0000
H`0000
H`0000
H`0000
H`0000
proposedRepairActions =
#0#
#0#
#0#
#0#
END OF OUTPUT FOR JOB 33
JOB: 34
PC Time&Date: 12:03:25 03/24/2005
NE Time&Date: 00:02:52 11/29/2004
USER NAME:

User_d

SW RELEASE:

01-04-17-06-26-51_05-02-23

COMMAND RESULT: Operation successful


ChangedConfigurationNotification:
name = BTSETEST:1
ChangeInfo = deleted
END OF OUTPUT FOR JOB 34

112

Id:0900d80580593f27

A50016-G5100-B333-04-7619

BS-4x / 82 II / 240 / 241 / 240XL commands

BCOM

The test results will be displayed at the end of the test phases.
Result TEST:
name =

TEST:<n>

testOutcome =

This field represents the test result; one of the following values can be displayed:
Pass

all the test phases are successfully


performed.

Inconclusive

the test is aborted by the system or


the test is terminated by the operator.

Fail

if at least one of the executed phases


fail.

mOts =

It is the identifier of the hardware object under test.

testTermination =

It specifies how the test is terminated, it can assume


the following values:
Normal

all the test phases are performed.

Abort

the test is aborted by system.

Cancel

the test is terminated by operator.

executedPhases
phaseId =
additionalWords =
....

It represents the list of the executed test phases (in


case of successful test result, all the test phases will
be listed).

failedPhases
phaseId =

It represents the list of the failed test phase; additional information is provided for each phase.

phaseId =
....
skippedPhases
phaseId =

It represents the list of the skipped phases; they are


displayed only for test stopped during it execution.

phaseId =
....
poprosedRepair Action
=

A list of most probable fail probable causes is shown


(max four messages)

Operation Failed
This NACK-message occurs in the following cases: Message cannot be performed, test
not supported, capacity restrictions, physical configuration cannot be performed, object
not locked.
Application Guidelines:
None.

A50016-G5100-B333-04-7619

Id:0900d80580593f27

113

BCOM

BS-4x / 82 II / 240 / 241 / 240XL commands

Example of Command Execution:


Perftest BCOM:NAME=RACK:0/BCOM:0;

SET BCOM
SET BCOM

NAME=RACK:0..7/BCOM:0..1 [,ANT<x>CELLNO=]
[,ANT<x>SCNRX=] [,ACONN=] [,FBAND=] [,BCOMTYPE=];

Command Tree:
MANAGED-ELEMENT h BSS-EQUIPMENT h BTSEP h RACK h BCOM h
SET BCOM
Applicability:
Phase 2 and Phase 3.
Visibility level: 2.
Command Description:
This command allows modification of the attributes of the BCOM. For setting of wiring
data attributes of BCOM the commands: SetWiringRx BCOM and SetWiringTx BCOM
must be used.
Long Names:
NAME

Address of the managed object

ANT<x>CELLNO
ANT<x>SCNRX

ant<x>CellNumber
ant<x>SecondCellNumberRx

ACONN

alarmConnector

FBAND

frequencyBand

BCOMTYPE

bcomType

System Responses:
Operation Completed
After command execution, a message of Changed Attribute Event Report is displayed.
A further message indicates the result of the operation. An example of set command is
the following:
JOB: 46
PC Time&Date: 12:07:06 03/24/2005
NE Time&Date: 00:06:33 11/29/2004
USER NAME:

User_d

COMMAND:

Set BCOM:NAME=RACK:0/BCOM:0;

SW RELEASE:

01-04-17-06-26-51_05-02-23

COMMAND RESULT: Operation successful

114

Id:0900d80580593f27

A50016-G5100-B333-04-7619

BS-4x / 82 II / 240 / 241 / 240XL commands

BCOM

END OF OUTPUT FOR JOB 46


Operation Failed
The specified attributes have not been set. In addition to the general NACK causes, a
specific NACK cause, which indicates that the command is inconsistent with the
physical configuration, is possible.
Application Guidelines:

The existing state and status attributes shall be assigned to the attributes group
STATES

<x> = 0 .. 5

With the SET BCOM command it is possible to 'unset' the parameters setting the
value 'NULL', e.g. the cell parameters. To 'unset' the parameters first you must use
BCOM SetWiringTx& Set WiringRx commands, then Set command (to unset cell
assignment).
Example:
SetWiringTX BCOM:NAME=RACK:0/BCOM:0, ANT0WDTX=<NULL>,
ANT1WDTX=<NULL>,
ANT2WDTX=<NULL>, ANT3WDTX=<NULL>,
,ANT4WDTX=<NULL>,,ANT5WDTX=<NULL>;
;
SetWiringRX BCOM:NAME=RACK:0/BCOM:0, ANT0WDRX=<NULL>,
ANT1WDRX=<NULL>,
ANT2WDRX=<NULL>, ANT3WDRX=<NULL>,
,ANT4WDRX=<NULL>,,ANT5WDRX=<NULL>;
;
Set BCOM:NAME=RACK:0/BCOM:0,ANT0CELLNO=<NULL>,
ANT0SCNRX=<NULL>,ANT1CELLNO=<NULL>,ANT1SCNRX=<NULL>,
ANT2CELLNO=<NULL>,ANT2SCNRX=<NULL>,ANT3CELLNO=<NULL>,
ANT3SCNRX=<NULL>,ANT4CELLNO=<NULL>,ANT4SCNRX=<NULL>,
ANT5CELLNO=<NULL>,ANT5SCNRX=<NULL>;

Example of Command Execution:


Set BCOM:NAME=RACK:0/BCOM:0,ant<x>CellNumber=2, ant<x>SecondCellNumberRx=2, ACONN=ENVA0,Fband=Gsm900,BCOMTYPE=NotSet;

SETWIRINGRX BCOM
SETWIRINGRX BCOM

A50016-G5100-B333-04-7619

NAME=RACK:0..7/BCOM:0..1 [,ANT<x>WDRX=];

Id:0900d80580593f27

115

BCOM

BS-4x / 82 II / 240 / 241 / 240XL commands

Command Tree:
MANAGED-ELEMENT h BSS-EQUIPMENT h BTSEP h RACK h BCOM h
SETWIRINGRX BCOM
Applicability:
Phase 2 and Phase 3.
Visibility level: 2.
Command Description:
This command allows modification of the wiring data attributes of the BCOM for RX path.
This command shall be used after creation of BCOM object. Up to 8 wiring destinations
can be set allowing to define also the configuration MDUX + HYBRID6 +COAMCO.
This is valid only for: BS240, BS240II, BS240XL, BS240XLII, BS241, BS241 II.
Long Names:
NAME

Address of the managed object

ANT<x>WDRX

ant<x>WiringDataRx

System Responses:
Operation Completed
After command execution, a message of Changed Attribute Event Report is displayed.
A further message indicates the result of the operation. An example of SetWiringRx
command is the following:
JOB: 56
PC Time&Date: 17.12.2007 10:19:03 +01:00
NE Time&Date: 01.01.1990 00:05:52 +00:00
USER NAME: User_d
COMMAND: SetWiringRx
BCOM:NAME=RACK:0/BCOM:0,ANT0WDRX=CU0N&CU1N&CU2N&CU3N&FCUMA
IN5N&FCUMAIN5N1&FCUMAIN6N&FCUMAIN6N1;
SW RELEASE: 01-04-18-01-18-01_07-12-14
COMMAND RESULT:Operation successful
ant0WiringDataRx = CU0N & CU1N & CU2N & CU3N & FCUMAIN5N &
FCUMAIN5N1& FCUMAIN6N & FCUMAIN6N1
END OF OUTPUT FOR JOB 56
Operation Failed

116

Id:0900d80580593f27

A50016-G5100-B333-04-7619

BS-4x / 82 II / 240 / 241 / 240XL commands

BCOM

In addition to the general NACK causes, a specific NACK cause, which indicates that
the command is inconsistent with the physical configuration, is possible.
Application Guidelines:

The 1 attribute for each antenna shall be assigned to 6 separate groups 'ANTENNA
<x>'

<x> = 0 .. 5

With the SETWIRINGRX BCOM command it is possible to 'unset' the parameters


setting the value 'NULL', for wiringDataRx attributes and with the SETWIRINGTX
BCOM command it is possible to 'unset' the parameters setting the value 'NULL' and
finally by using a command "SET BCOM" to 'unset' the cell parameters

Example:
SetWiringRx
BCOM:NAME=RACK:0/BCOM:0,ANT0WDRX=<NULL>,
ANT1WDRX=<NULL>,ANT2WDRX=<NULL>,
ANT3WDRX=<NULL>, ANT4WDRX=<NULL>, ANT5WDRX=<NULL>,
;
SetWiringTx
BCOM:NAME=RACK:0/BCOM:0,ANT0WDTX=<NULL>,
ANT1WDTX=<NULL>,ANT2WDTX=<NULL>,
ANT3WDTX=<NULL>, ANT4WDTX=<NULL>, ANT5WDTX=<NULL>,

Set BCOM:NAME=RACK:0/BCOM:0,ANT0CELLNO=<NULL>,
ANT0SCNRX=<NULL>,ANT1CELLNO=<NULL>,ANT1SCNRX=<NULL>,
ANT2CELLNO=<NULL>,ANT2SCNRX=<NULL>,ANT3CELLNO=<NULL>,
ANT3SCNRX=<NULL>,ANT4CELLNO=<NULL>,ANT4SCNRX=<NULL>,
ANT5CELLNO=<NULL>,ANT5SCNRX=<NULL>;

Example of Command Execution:


SetWiringRx BCOM:NAME=RACK:0/BCOM:0,
ANT0WDRX=CU0N&CU1N&CU2N&CU3N&FCUMAIN5N&FCUMAIN5N1&FCUMAIN
6N&FCUMAIN6N1;

g The wiring data of cell configurations with MDUX, HYBRID6 and COAMCO are
neither completely visible nor configurable via RC, SetWiringRx BCOM command
not forseen for RC, when to display the wiring for this configuration always max 2
CUs.TX wiring destinations and max 4 CUs Rx wiring destinations for each corresponding BCOM port is displayed even if 4 CUs for TX path and 8 CUs Rx path are
wired.

A50016-G5100-B333-04-7619

Id:0900d80580593f27

117

BCOM

BS-4x / 82 II / 240 / 241 / 240XL commands

SETWIRINGTX BCOM
SETWIRINGTX BCOM

NAME=RACK:0..7/BCOM:0..1 [,ANT<x>WDTX=];

Command Tree:
MANAGED-ELEMENT h BSS-EQUIPMENT h BTSEP h RACK h BCOM h
SETWIRINGTX BCOM
Applicability:
Phase 2 and Phase 3.
Visibility level: 2.
Command Description:
This command allows modification of the wiring data attributes of the BCOM for TX path.
This command shall be used after creation of BCOM object. Up to 4 wiring destinations
can be set allowing to define also the configuration MDUX + HYBRID6 +COAMCO.
This is valid only for: BS240, BS240II, BS240XL, BS240XLII, BS241, BS241 II.
Long Names:
NAME

Address of the managed object

ANT<x>WDTX

ant<x>WiringDataTx

System Responses:
Operation Completed
After command execution, a message of Changed Attribute Event Report is displayed.
A further message indicates the result of the operation. An example of SetWiringTx
command is the following:
JOB: 53
PC Time&Date: 17.12.2007 10:17:53 +01:00
NE Time&Date: 01.01.1990 00:04:42 +00:00
USER NAME: User_d
COMMAND: SetWiringTx
BCOM:NAME=RACK:0/BCOM:0,ANT0WDTX=CU0&CU1&CU2&CU3;
SW RELEASE: 01-04-18-01-18-01_07-12-14
COMMAND RESULT:Operation successful
ant0WiringDataTx = CU0 & CU1 & CU2 & CU3
END OF OUTPUT FOR JOB 53
Operation Failed
None.

118

Id:0900d80580593f27

A50016-G5100-B333-04-7619

BS-4x / 82 II / 240 / 241 / 240XL commands

BCOM

Application Guidelines:

The 1 attribute for each antenna shall be assigned to 6 separate groups 'ANTENNA
<x>'.

<x> = 0 .. 5

With the SETWIRINGTX BCOM command it is possible to 'unset' the parameters


setting the value 'NULL', for wiringDataTx attributes and with the SETWIRINGRX
BCOM command it is possible to 'unset' the parameters setting the value 'NULL' and
finally by using a command "SET BCOM" to 'unset' the cell parameters.
Example:
SetWiringTx
BCOM:NAME=RACK:0/BCOM:0,ANT0WDTX=<NULL>,
ANT1WDTX=<NULL>,ANT2WDTX=<NULL>,
ANT3WDTX=<NULL>, ANT4WDTX=<NULL>, ANT5WDTX=<NULL>,
SetWiringRx
BCOM:NAME=RACK:0/BCOM:0,ANT0WDRX=<NULL>,
ANT1WDRX=<NULL>,ANT2WDRX=<NULL>,
ANT3WDRX=<NULL>, ANT4WDRX=<NULL>, ANT5WDRX=<NULL>,;
Set BCOM:NAME=RACK:0/BCOM:0,ANT0CELLNO=<NULL>,
ANT0SCNRX=<NULL>,ANT1CELLNO=<NULL>,ANT1SCNRX=<NULL>,
ANT2CELLNO=<NULL>,ANT2SCNRX=<NULL>,ANT3CELLNO=<NULL>,
ANT3SCNRX=<NULL>,ANT4CELLNO=<NULL>,ANT4SCNRX=<NULL>,
ANT5CELLNO=<NULL>,ANT5SCNRX=<NULL>

Example of Command Execution:


SetWiringTx BCOM:NAME=RACK:0/BCOM:0,ANT0WDTX=CU0&CU1&CU2&CU3;

g The wiring data of cell configurations with MDUX, HYBRID6 and COAMCO are
neither completely visible nor configurable via RC. SetWiringTx BCOM command is
not forseen for RC, when the wiring for this configuration is displayed always max 2
CUs.
TX wiring destinations and max 4 CUs Rx wiring destinations for each corresponding BCOM port is displayed even if 4 CUs for TX path and 8 CUs Rx path are wired.

STOPTEST BCOM
STOPTEST BCOM

NAME=RACK:0..7/BCOM:0..1;

Command Tree:
MANAGED-ELEMENT h BSS-EQUIPMENT h BTSEP h RACK h BCOM h
STOPTEST BCOM
Applicability:
Phase 2 and Phase 3.

A50016-G5100-B333-04-7619

Id:0900d80580593f27

119

BCOM

BS-4x / 82 II / 240 / 241 / 240XL commands

Visibility level: 1.
Command Description:
This command is used to stop a diagnostic previously started.
Long Names:
NAME

Address of the managed object

System Responses:
Operation Completed
Test has been stopped. The System Responses will not be addressed to the MOT but
to the object.

Result TEST:
name =

TEST:<n>

testOutcome =

inconclusive

mOts =

It is the identifier of the hardware object under test.

testTermination =

Cancel

executedPhases
phaseId =
...
.

It represents the list of the executed test phases; the


list is not shown for test in the waiting list (queued).

failedPhases
phaseId =

It represents the list of the failed test phase;

phaseId =

additional information is provided for each phase.

....
skippedPhases
phaseId =
phaseId =

It represents the list of the skipped phases;the list is


not shown for test in the waiting list (queued).

Operation Failed
Test has not been stopped. This NACK-message can occur when the specified test is
not running or in case of test which cannot be stopped.
Application Guidelines:
None.
Example of Command Execution:
Stoptest BCOM:NAME=RACK:0/BCOM:0;

UNLOCK BCOM
UNLOCK BCOM

120

NAME=RACK:0..7/BCOM:0..1;

Id:0900d80580593f27

A50016-G5100-B333-04-7619

BS-4x / 82 II / 240 / 241 / 240XL commands

BCOM

Command Tree:
MANAGED-ELEMENT h BSS-EQUIPMENT h BTSEP h RACK h BCOM h
UNLOCK BCOM
Applicability:
Phase 2 and Phase 3.
Visibility level: 1.
Command Description:
This command changes the administrative state of the BCOM.
Long Names:
NAME

Address of the managed object

System Responses:
Operation Completed
The specified change of administrative state has been perfomed:
JOB: 36
PC Time&Date: 12:03:45 03/24/2005
NE Time&Date: 00:03:12 11/29/2004
USER NAME:

User_d

COMMAND:

Unlock BCOM:NAME=RACK:0/BCOM:0;

SW RELEASE:

01-04-17-06-26-51_05-02-23

COMMAND RESULT: Operation successful


administrativeState = Unlocked
END OF OUTPUT FOR JOB 36

CHANGED STATE EVENT REPORT:


This provides information about the administrative state, the operational state and the
availability status every time a state change occurs:
JOB: 37
PC Time&Date: 12:03:45 03/24/2005
NE Time&Date: 00:03:12 11/29/2004

A50016-G5100-B333-04-7619

Id:0900d80580593f27

121

BCOM

BS-4x / 82 II / 240 / 241 / 240XL commands

USER NAME:

User_d

SW RELEASE:

01-04-17-06-26-51_05-02-23

COMMAND RESULT: Operation successful


CHANGED STATE EVENT REPORT:
NAME = RACK:0/BCOM:0
Administrative State = UNLOCKED
Notification Identifier = 29
END OF OUTPUT FOR JOB 37
Operation Failed
The specified change of administrative state has not been performed.
Application Guidelines:
None.
Example of Command Execution:
Unlock BCOM:NAME=RACK:0/BCOM:0;

122

Id:0900d80580593f27

A50016-G5100-B333-04-7619

BS-4x / 82 II / 240 / 241 / 240XL commands

BPORT

BPORT
The object BPORT identifies one of the 2 PCM30/24 interfaces on the COBA and one
of the 6 PCM30/24 interfaces on the COSA. The object BPORT holds the configuration
data of one Abis port.

CREATE BPORT
CREATE BPORT

NAME=BPORT:0..7 [,BERT=] [,L1CTRLTS=] ,L1PT=


[,L1RAT=] ,LCONF= [,LIMP=];

Command Tree:
MANAGED-ELEMENT h BSS-EQUIPMENT h BTSEP h BPORT h CREATE
BPORT
Applicability:
Phase 2 and Phase 3.
Visibility level: 2.
Command Description:
This command is used for the Handling of PCM-Line Configuration and adds the BPORT
(BTSE Port) together with its attributes to the BTSE data base. The object BPORT holds
the configuration data of one Abis port. The instance number of this object is related to
the physical Abis port number (e.g.: Instance 0 is related to the physical port 1 (OVPT),
which allows the connection of the BTSE to the Abis line1 and so on).
Long Names:
NAME

Address of the managed object

BERT

bitErrorRateThreshold

L1CTRLTS

layer1ControlTs

L1PT

layer1ProtocolType

L1RAT

layer1RemoteAlarmType

LCONF

lineConfiguration

LIMP

lineImpedance

System Responses:
Operation Completed
After command execution, a message of Changed Configuration Notification is displayed.
A further message indicates the result of the operation. An example of create command
is the following:
JOB: 42
PC Time&Date: 11:55:28 03/23/2005
NE Time&Date: 12:57:03 09/15/2004

A50016-G5100-B333-04-7619

Id:0900d805805944a2

123

BPORT

BS-4x / 82 II / 240 / 241 / 240XL commands

USER NAME:

User_e

SW RELEASE:
cessful

01-04-17-01-26-51_05-02-23 COMMAND RESULT: Operation suc-

ChangedConfigurationNotification:
name = BPORT:1
ChangeInfo = created
END OF OUTPUT FOR JOB 42
JOB: 43
PC Time&Date: 11:55:28 03/23/2005
NE Time&Date: 12:57:03 09/15/2004
USER NAME:

User_e

COMMAND:

Create BPORT:NAME=BPORT:1,L1PT=pcm30crc4,LCONF=star;

SW RELEASE:

01-04-17-01-26-51_05-02-23

COMMAND RESULT: Operation successful


layer1ProtocolType = pcm30crc4
lineConfiguration = star
END OF OUTPUT FOR JOB 43
Operation Failed
The specified Object has not been created. In addition to the general NACK causes, a
specific NACK cause, which indicates that the command is inconsistent with the
physical configuration, is possible. An example is the following:
JOB: 44
PC Time&Date: 11:55:52 03/23/2005
NE Time&Date: 12:57:27 09/15/2004
USER NAME:

User_e

COMMAND:

Create BPORT:NAME=BPORT:2,L1PT=pcm30crc4,LCONF=star;

SW RELEASE:

01-04-17-01-26-51_05-02-23

COMMAND RESULT: OPERATION FAILED

124

Id:0900d805805944a2

A50016-G5100-B333-04-7619

BS-4x / 82 II / 240 / 241 / 240XL commands

BPORT

MO already created (-159)


END OF OUTPUT FOR JOB 44
Application Guidelines:

Wildcard addressing is not possible

To guarantee a correct transition of SW releases the operator must use BPort


instance 0 for O&M link

Changing or setting of layer1ProtocolType or layer1RemoteAlarm attributes means


a temporary loss of service for the whole BTSE

Layer1ControlTS must be different to the related BTSM-O&M signalling link

Layer1ControlTS (if activated) must not be used for other purposes (e.g. signalling,
traffic or cross connection and vice versa)

SpecialBitRobbing attribute is allowed only for PCM24 and means that a special bit
(bit 2) is used for signalling of a remote alarm

BPORTs (0&1, 2&3, 4&5, 6&7) form port pairs which are short-circuited during
BTSE coming up

Bport-0 is clock master for BTSE, all other Bports are slaves. Therefore, PCM line
connected to Bport-0 must arrive from different network entity

To configure a line circuit (e.g.: multidrop, loop) 2 BPort objects have to be created
by the operator. As long the 2 objects are not available all BTSEs located behind on
this circuit are not reachable. Line alarms detected by one Abis port are mapped to
the associated BPort instance

One star circuit (only one port is involved) is allowed per port pair and must be
placed on the lower port number

Creation of the second port on a port pair (in case of a multidrop/loop circuit) must
lead always to the same settings of the attributes as the first port has with the following exceptions
1) Activation of a layer1ControlTimeslot is only allowed for the first port in case of a
multidrop circuit
2) Attribute bitErrorRateThresholds can be set independently

If COBA2P8 is installed and COSA is disabled/not Installed, the BPORT:2-7 are in


Enable.null state but they cannot be used because the HW does not support them.
If COBA4P12 is installed and COSA is disabled/not Installed, the BPORT:2,3 are in
Enable.degraded state and the BPORT:4-7 are in Enable.null but they cannot be
used because the HW does not support them

g This is valid for all BTSplus except for 82II.


Example of Command Execution:
Create BPORT:NAME=BPORT:0,L1PT=pcm30crc4,LCONF=star,
BERT=E10_3-E10_3,L1CTRLTS=0-0,L1RAT=ProtocolSignalling,

A50016-G5100-B333-04-7619

Id:0900d805805944a2

125

BPORT

BS-4x / 82 II / 240 / 241 / 240XL commands

LIMP=Imp100or120Ohm;

DELETE BPORT
DELETE BPORT

NAME=BPORT:0..7;

Command Tree:
MANAGED-ELEMENT h BSS-EQUIPMENT h BTSEP h BPORT h DELETE
BPORT
Applicability:
Phase 2 and Phase 3.
Visibility level: 2.
Command Description:
This command deletes the BPORT (BTSE port) from the BTSE data base.
Long Names:
NAME

Address of the managed object

System Responses:
Operation Completed
After command execution, a message of Changed Configuration Notification is displayed. A further message indicates the result of the operation. An example of delete
command is the following:
JOB: 45
PC Time&Date: 11:55:52 03/23/2005
NE Time&Date: 12:57:27 09/15/2004
USER NAME:

User_e

SW RELEASE:

01-04-17-01-26-51_05-02-23

COMMAND RESULT: Operation successful


ChangedConfigurationNotification:
NAME=BPORT:2
ChangeInfo = deleted
END OF OUTPUT FOR JOB 45
JOB: 46

126

Id:0900d805805944a2

A50016-G5100-B333-04-7619

BS-4x / 82 II / 240 / 241 / 240XL commands

BPORT

PC Time&Date: 11:55:56 03/23/2005


NE Time&Date: 12:57:31 09/15/2004
USER NAME:

User_e

COMMAND:

Delete BPORT:NAME=BPORT:0;

SW RELEASE:

01-04-17-01-26-51_05-02-23

COMMAND RESULT: Operation successful


END OF OUTPUT FOR JOB 46
Operation Failed
The specified Object has not been deleted. Additionally to the general NACK causes, a
specific NACK cause, meaning that the command is inconsistent with physical configuration, is possible.
Application Guidelines:

Before Deletion of a BPort instance in phase 3, the object must be locked before

Deletion in phase 3 is allowed only if no TSL is assigned to BPort (XCONNECT


defined)

The BPORT 0 is one of the "Minimal Parameters" of the BTSE. If the BPORT 0 is
deleted, the entire BTSE is out of service (only Phase 2)

BPORT 0 cannot be deleted in Phase 3

Example of Command Execution:


Delete BPORT:NAME=BPORT:0;

GET BPORT
GET BPORT

NAME=BPORT:0..7 [,REQATTL=ALS, AST, AVS, BERT,


L1CTRLTS, L1PT, L1RAT, LCONF, LSIND, LIMP, OST,
PRDIRECT, PRS, RELFUNCOBJ];

Command Tree:
MANAGED-ELEMENT h BSS-EQUIPMENT h BTSEP h BPORT h GET
BPORT
Applicability:
Phase 2 and Phase 3.
Visibility level: 0.
Command Description:
This command displays the attributes of the PCM lines connected to the COBA (Core
Basis).
Long Names:
NAME

Address of the managed object

REQATTL

Required attribute list

A50016-G5100-B333-04-7619

Id:0900d805805944a2

127

BPORT

BS-4x / 82 II / 240 / 241 / 240XL commands

ALS

alarmStatus

AST

administrativeState

AVS

availabilityStatus

BERT

bitErrorRateThreshold

L1CTRLTS

layer1ControlTs

L1PT

layer1ProtocolType

L1RAT

layer1RemoteAlarmType

LCONF

lineConfiguration

LSIND

lineStatusIndication

LIMP

lineImpedance

OST

operationalState

PRDIRECT

preferredDirection

PRS

proceduralStatus

RELFUNCOBJ

relatedFuncObjects

System Responses:
Operation Completed
A message indicates the result of the operation. An example of get command is the following:
JOB: 5
PC Time&Date: 11:31:23 03/23/2005
NE Time&Date: 11:29:14 09/15/2004
USER NAME:

User_e

COMMAND:

GET BPORT:NAME=BPORT:0;

SW RELEASE:

01-04-17-01-26-51_05-02-23

COMMAND RESULT: Operation successful


alarmStatus = CLEARED
administrativeState = Unlocked
availabilityStatus = NULL
bitErrorRateThreshold =
lowerThreshold = E10_5
upperThreshold = E10_3
layer1ControlTs =
TSL = 0
SSL = 0
layer1ProtocolType = pcm30crc4

128

Id:0900d805805944a2

A50016-G5100-B333-04-7619

BS-4x / 82 II / 240 / 241 / 240XL commands

BPORT

layer1RemoteAlarmType = ProtocolSignalling
lineConfiguration = multidrop
lineStatusIndication =
remoteAlarmInd = FALSE
frameSynchronizationLoss = FALSE
CRCFailure = FALSE
noLevel = FALSE
CRCRemoteEnviroment = FALSE
BERTLowerThreshold = FALSE
BERTUpperThreshold = FALSE
promptMaintenanceAlarmInd = FALSE
lineImpedance = accDIP
operationalState = ENABLED
proceduralStatus = NULL
preferredDirection = Null
relatedFuncObjects =
END OF OUTPUT FOR JOB 5
Operation Failed
The GET command has not been successfully executed. A general NACK will indicate
possible errors or a specific NACK strictly related to the single command is possible.
Application Guidelines:
None.
Example of Command Execution:
Get BPORT:NAME=BPORT:0,REQATTL=ALS&AST&AVS&BERT&
L1CTRLTS&L1RAT&L1PT&LCONF&LIMP&LSIND&OST&PRDIRECT&PRS&
RELFUNCOBJ;

LOCK BPORT
LOCK BPORT

NAME=BPORT:0..7;

Command Tree:
MANAGED-ELEMENT h BSS-EQUIPMENT h BTSEP h BPORT h LOCK
BPORT
Applicability:
Phase 2 and Phase 3.
Visibility level: 1.

A50016-G5100-B333-04-7619

Id:0900d805805944a2

129

BPORT

BS-4x / 82 II / 240 / 241 / 240XL commands

Command Description:
This command changes the administrative state of the BPORT object.
Long Names:
NAME

Address of the managed object

System Responses:
Operation Completed
The specified change of administrative state has been perfomed:
JOB: 47
PC Time&Date: 11:56:00 03/23/2005
NE Time&Date: 12:57:35 09/15/2004
USER NAME:

User_e

COMMAND:

Lock BPORT:NAME=BPORT:0;

SW RELEASE:
cessful

01-04-17-01-26-51_05-02-23 COMMAND RESULT: Operation suc-

administrativeState = LOCKED
END OF OUTPUT FOR JOB 47

CHANGED STATE EVENT REPORT:


This provides information about the administrative state, the operational state and the
availability status every time a state change occurs:
JOB: 48
PC Time&Date: 11:56:22 03/23/2005
NE Time&Date: 12:57:57 09/15/2004
USER NAME:

User_e

SW RELEASE:

01-04-17-01-26-51_05-02-23

COMMAND RESULT: Operation successful


CHANGED STATE EVENT REPORT:
NAME=BPORT:0;

130

Id:0900d805805944a2

A50016-G5100-B333-04-7619

BS-4x / 82 II / 240 / 241 / 240XL commands

BPORT

Administrative State = LOCKED


Notification Identifier = 143452
END OF OUTPUT FOR JOB 48
Operation Failed
The specified change of administrative state has not been performed (e.g. the object is
redundant and its spare copy is disabled or already locked, a subordinate resource
cannot go into disabled state with "dependency" availability status).
Application Guidelines:

BPORT 0 cannot be locked in Phase 3

Example of Command Execution:


Lock BPORT:NAME=BPORT:0;

SET BPORT
SET BPORT

NAME=BPORT:0..7 [,BERT=] [,L1CTRLTS=] [,L1RAT=]


[,LCONF=] [,LIMP=];

Command Tree:
MANAGED-ELEMENT h BSS-EQUIPMENT h BTSEP h BPORT h SET
BPORT
Applicability:
Phase 2 and Phase 3.
Visibility level: 2.
Command Description:
This command permits modification of the attributes of the BPORT (BTSE port), previously created with the (create) CREATE BPORT command. The object BPORT holds
the configuration data of one Abis port.
Long Names:
NAME

Address of the managed object

BERT

bitErrorRateThreshold

L1CTRLTS

layer1ControlTs

L1RAT

layer1RemoteAlarmType

LCONF

lineConfiguration

LIMP

lineImpedance

System Responses:
Operation Completed
The specified attribute has been set. In addition, a Changed Attribute Event Report indicates that the command has been successfully executed:

A50016-G5100-B333-04-7619

Id:0900d805805944a2

131

BPORT

BS-4x / 82 II / 240 / 241 / 240XL commands

JOB: 15
PC Time&Date: 11:32:16 03/23/2005
NE Time&Date: 11:30:07 09/15/2004
USER NAME:

User_e

COMMAND:

Set BPORT:NAME=BPORT:0,BERT=E10_5-E10_3;

SW RELEASE:

01-04-17-01-26-51_05-02-23

COMMAND RESULT: Operation successful


bitErrorRateThreshold =
lowerThreshold = E10_5
upperThreshold = E10_3
END OF OUTPUT FOR JOB 15
Operation Failed
The specified attributes have not been set. In addition to the general NACK causes, a
specific NACK cause, which indicates that the command is inconsistent with physical
configuration, is possible.
Application Guidelines:

The layer1ControlTS attribute is applicable only for the line configuration "Loop"

Changing or setting of layer1RemoteAlarmType attribute means a temporary loss of


service for the whole BTSE

Layer1ControlTS must be different to the related BTSM-O&M signalling link

SpecialBitRobbing attribute is allowed only for PCM24 and means that a special bit
(bit 2) is used for signalling of a remote alarm

Example of Command Execution:


Set BPORT:NAME=BPORT:0,BERT=E10_3-E10_3,L1CTRLTS=0-0,
L1RAT=ProtocolSignalling,LCONF=star,LIMP=Imp100or120Ohm;

UNLOCK BPORT
UNLOCK BPORT

NAME=BPORT:0..7;

Command Tree:
MANAGED-ELEMENT h BSS-EQUIPMENT h BTSEP h BPORT h UNLOCK
BPORT
Applicability:
Phase 2 and Phase 3.

132

Id:0900d805805944a2

A50016-G5100-B333-04-7619

BS-4x / 82 II / 240 / 241 / 240XL commands

BPORT

Visibility level: 1.
Command Description:
This command changes the administrative state of the BPORT (BTSE port).
Long Names:
NAME

Address of the managed object

System Responses:
Operation Completed
The specified change of administrative state has been perfomed:
JOB: 185
PC Time&Date: 12:06:51 03/23/2005
NE Time&Date: 13:08:26 09/15/2004
USER NAME:

User_e

COMMAND:

UNLOCK BPORT:NAME=BPORT:0;

SW RELEASE:

01-04-17-01-26-51_05-02-23

COMMAND RESULT: Operation successful


administrativeState = UNLOCKED
END OF OUTPUT FOR JOB 185

CHANGED STATE EVENT REPORT:


This provides information about the administrative state, the operational state and the
availability status every time a state change occurs:
JOB: 186
PC Time&Date: 12:06:51 03/23/2005
NE Time&Date: 13:08:26 09/15/2004
USER NAME:

User_e

SW RELEASE:

01-04-17-01-26-51_05-02-23

COMMAND RESULT: Operation successful


CHANGED STATE EVENT REPORT:

A50016-G5100-B333-04-7619

Id:0900d805805944a2

133

BPORT

BS-4x / 82 II / 240 / 241 / 240XL commands

NAME=BPORT:0;
Administrative State = UNLOCKED
Notification Identifier = 135872
END OF OUTPUT FOR JOB 186
Operation Failed
The specified change of administrative state has not been performed.
Application Guidelines:
None.
Example of Command Execution:
Unlock BPORT:NAME=BPORT:0;

134

Id:0900d805805944a2

A50016-G5100-B333-04-7619

BS-4x / 82 II / 240 / 241 / 240XL commands

BTS

BTS
The BTS object locates a cell connected to BSC. Logically it represents all the information related to the cell and to its configuration.

GET BTS
GET BTS

NAME=BTS:0..11 [,REQATTL=ACBQPFF, ACBQPMAX,


ACEFLFF, ACFERMAX, ACLNKTYP, ACMINEFLDMA,
ACMAXEFLDMA, ACPER, AMRLKAT, AMRLKATWFS,
ANTHOPMOD, ANTHOPP, ANTHOPST, ARFACCHACMDF, ASCICIPH, AST, AVS, BCCHFREQ, BSIC,
BTSISHOP, BURNOFFS, SYSID, CELLTYPE, CUCONF,
DTMHOMTIMER, EAC, EANTHOP, EEOTD, EEXCDIST,
ERFACCHALPDMF, ERFACCHCMDF, ERSACCHDL,
ERSACCHUL, ETOP, ETXDIVTS, EXCDIST, FACCHQ,
FACHBT, FRANOFFS, GSMTIME, HOPMODE, INTAVEPAR, INTCLASS, INTLVBND, MSTXPMAX, MSTXPMAXC,
NEPTTREP, NTWTYPE, NY1, NY2, OST, PCCCHLDI,
PNOFACCH, PWROUT, RACHBT, RACHLAS, RELEQUIPOBJ, REPTYP, RFRSINDP, RSACCHRXLDL, RSACCHRXLUL, RSACCHTODL, RSACCHTOUL,
RXSIGLEVADJ, RXSIGLEVADJC, RXSWCURSET, SWBCAPABILITY, SWBSERVSTATE, T3105, T3151,
TCCCHLDI];

Command Tree:
MANAGED-ELEMENT h BSS-FUNCTIONAL h BTSM h BTS h GET BTS
Applicability:
Phase 3.
Visibility level: 0.
Command Description:
This command displays the cell-specific global attributes of a chosen BTS.
Long Names:
NAME

Address of the managed object

REQATTL

Required attribute list

ACBQPFF

acBQPFgtFac

ACBQPMAX

acBQPMax(%)

ACEFLFF

acEFLFgtFac

ACFERMAX

acFERMax(%)

ACLNKTYP

acLinkType

ACMINEFLDMA
ACMAXEFLDMA
ACPER

A50016-G5100-B333-04-7619

acMinEFLDMA(%)
acMaxEFLDMA(%)

acPeriod

Id:0900d805805944a4

135

BTS

BS-4x / 82 II / 240 / 241 / 240XL commands

AMRLKAT

aMRLinkAdapTuning

AMRLKATWFS

aMRLinkAdapTuningWFS(dB)

ANTHOPMOD

antennaHoppingMode

ANTHOPP

antennaHoppingPeriod

ANTHOPST

antennaHoppingStatus

ARFACCHACMDF

applyRFacchOnAnyCmdFrame

ASCICIPH

enableCiphForASCI

AST

administrativeState

AVS

availabilityStatus

BCCHFREQ

bcchFrequency

BSIC

bsIdentityCode

BTSISHOP

btsIsHopping

BURNOFFS

burstNumberOffset

SYSID

cellAllocationNumber

CELLTYPE

cellType

CUCONF

carrierUnitConfiguration

DTMHOMTIMER

hoDTMTimer(SACCH_multiframe_480/470ms)

EAC

enableAc

EANTHOP

enableAntennaHopping

EEOTD

enableEOTD

EEXCDIST

enableExcessiveDistance

ERFACCHALPDMF
ERFACCHCMDF

enableRFacchOnCmdFrames

ERSACCHDL

enableRSacchDL

ERSACCHUL

enableRSacchUL

ETOP

enableTOP

ETXDIVTS

enableTxDivTimeShift

EXCDIST

excessiveDistance(km)

FACCHQ

facchQual

FACHBT

fachBusyThreshold(dBm)

FRANOFFS

frameNumberOffset

GSMTIME

gsmTime

HOPMODE

hoppingMode

INTAVEPAR

intaveParameter

INTCLASS

enableInterferenceClass

INTLVBND

interferenceLevelBoundaries

MSTXPMAX

mSTxPwrMax(*dBm mapped)

MSTXPMAXC
NEPTTREP

136

enableRFacchOnAnyLapdmFrame

mSTxPwrMaxCompl
notDataRepCount

Id:0900d805805944a4

A50016-G5100-B333-04-7619

BS-4x / 82 II / 240 / 241 / 240XL commands

BTS

NTWTYPE

networkType

NY1

ny1

NY2

ny2

OST

operationalState

PCCCHLDI

periodCcchLoadIndication(sec)

PNOFACCH

periodNotificationFACCH(sec)

PWROUT

powerOutputThresholds

RACHBT

rachBusyThreshold(dBm)

RACHLAS

rachLoadAveragingSlots

RELEQUIPOBJ

relatedEquipObjects

REPTYP

reportType

RFRSINDP

rfResourceIndicationPeriod

RSACCHRXLDL

repSacchRxLevDL

RSACCHRXLUL

repSacchRxLevUL

RSACCHTODL

repSacchTimeOutDL

RSACCHTOUL

repSacchTimeOutUL

RXSIGLEVADJ

rxSigLevAdjust

RXSIGLEVADJC

rxSigLevAdjustCompl

RXSWCURSET

rxSwitchCurrentSetting

SWBCAPABILITY

switchedBeamCapability

SWBSERVSTATE

switchedBeamServState

T3105

btsTimer3105(*10ms)

T3151

uplBusyRepRate

TCCCHLDI

thresholdCcchLoadIndication

System Responses:
Operation Completed
A message indicates the result of the operation. An example of get command is the following:
JOB: 6
PC Time&Date: 05.05.2008 10:43:11 +02:00
NE Time&Date: 05.05.2008 10:27:15 +01:00
USER NAME:

User_f

COMMAND:

Get BTS:NAME=BTS:0;

SW RELEASE:

01-04-19-01-07-01_08-04-03

COMMAND RESULT: Operation successful

A50016-G5100-B333-04-7619

Id:0900d805805944a4

137

BTS

BS-4x / 82 II / 240 / 241 / 240XL commands

acBQPFgtFac = 0.2
acBQPMax(%) = 5
acEFLFgtFac = 0.04
acFERMax(%) = 5.0
acLinkType = UL_SAMPLES_ONLY
acMaxEFLDMA(%) = per_50
acMinEFLDMA(%) = per_10
acPeriod = SACCH_120
administrativeState = Unlocked
aMRLinkAdapTuning = 100
aMRLinkAdapTuningWFS(dB) = 0.0
antennaHoppingMode = ALLTRX
antennaHoppingPeriod = ALL
antennaHoppingStatus = FALSE
applyRFacchOnAnyCmdFrame = FALSE
availabilityStatus = NULL
bcchFrequency = 1
bsIdentityCode =
BCC = 7
NCC = 7
btsIsHopping = FALSE
btsTimer3105(*10ms) = 100
burstNumberOffset = 0
carrierUnitConfiguration = HOMOGENEOUS
cellAllocationNumber = BB900
cellType = STDCELL
enableAc = FALSE
enableAntennaHopping = FALSE
enableCiphForASCI = FALSE
enableEOTD = TRUE
enableExcessiveDistance = FALSE
enableInterferenceClass = TRUE
enableRFacchOnAnyLapdmFrame = NOT_SET
enableRFacchOnCmdFrames = NOT_SET
enableRSacchDL = NOT_SET
enableRSacchUL = NOT_SET
enableTOP = NOT_SET
enableTxDivTimeShift = FALSE
excessiveDistance(km) = 100

138

Id:0900d805805944a4

A50016-G5100-B333-04-7619

BS-4x / 82 II / 240 / 241 / 240XL commands

BTS

facchQual = 6
fachBusyThreshold(dBm) = -109
frameNumberOffset = 0
gsmTime = 9624
hoDTMTimer(SACCH_multiframe_480/470ms) = 4
hoppingMode = BBHOP
intaveParameter = 31
interferenceLevelBoundaries =
intThrBou1 = 10
intThsBou2 = 25
intThsBou3 = 40
intThsBou4 = 55
intThsBou5 = 63
mSTxPwrMax(*dBm_mapped) = 15
mSTxPwrMaxCompl = 4
mobileCountryCode =
MCC = "555"
networkType = GSMDCS
notDataRepCount = 3
ny1 = 14
ny2 = 4
operationalState = ENABLED
periodCcchLoadIndication(sec) = 255
periodNotificationFACCH(sec) = 2.5
powerOutputThresholds =
oPwrFaultThreshold = m10db
redOutPwrThreshold = m6db
excesOutPwrThresh = db5
rachBusyThreshold(dBm) = -109
rachLoadAveragingSlots = 204
relatedEquipObjects = Null
reportType = NORMAL
repSacchRxLevDL = 10
repSacchRxLevUL = 7
repSacchTimeOutDL = 4
repSacchTimeOutUL = 4
rfResourceIndicationPeriod = 31
rxSigLevAdjust = Null
rxSigLevAdjustCompl = Null

A50016-G5100-B333-04-7619

Id:0900d805805944a4

139

BTS

BS-4x / 82 II / 240 / 241 / 240XL commands

rxSwitchCurrentSetting = NULL
switchedBeamCapability = none
switchedBeamServState = NULL
thresholdCcchLoadIndication = 10
uplBusyRepRate = 2
END OF OUTPUT FOR JOB 6
Operation Failed
The GET command has not been successfully executed. A general NACK will indicate
possible errors or a specific NACK strictly related to the single command is possible.
Application Guidelines:

The attribute HOPMODE (hoppingMode) can be set only if there are no subordinate
frequency hopping system equipped

When the attribute INTCLASS is enabled "RF resource indication" messages (relevant to the attributes INTAVEPAR, INTLVBND and RFRSINDP) are sent to the BSC

Values indicating more than 35 Km in the attribute EXCDIST are valid only for
extended cells

The attributes ETXDIVTS, TXDIVTSEXCPT and TXDIVTSPAR have only functionality for hh=04-01 and hh=04-06

The attributes TXDIVTSEXCPT and TXDIVTSPAR are available with the command
GET BTS TIMER

Example of Command Execution:


Get BTS:NAME=BTS:0,REQATTL=ACBQPFF &ACBQPMAX &ACEFLFF &ACFERMAX&ACLNKTYP &ACMINEFLDMA &ACMAXEFLDMA &ACPER &AMRLKAT&ANTHOPMOD &ANTHOPP &ANTHOPST &ARFACCHACMDF &ASCICIPH
&AST&AVS &BCCHFREQ &BSIC &BTSISHOP &BURNOFFS &SYSID &CELLTYPE&CUCONF &DTMHOMTIMER &EAC &EANTHOP &EEOTD &EEXCDIST
&ERFACCHALPDMF&ERFACCHCMDF &ETOP &ETXDIVTS &EXCDIST &FACCHQ
&FRANOFFS&GSMTIME &HOPMODE &INTAVEPAR &INTCLASS
&INTLVBND&MSTXPMAX &MSTXPMAXC &NTWTYPE &NY1 &NY2 &OST
&PCCCHLDI &PNOFACCH&PWROUT &RACHBT &RACHLAS &RELEQUIPOBJ
&REPTYP &RFRSINDP&RXSIGLEVADJ &RXSIGLEVADJC &RXSWCURSET &SWBCAPABILITY&SWBSERVSTATE &T3105 &TCCCHLDI;

GET BTS TIMER


GET BTS TIMER

NAME=BTS:0..11 ,REQATTL=STATIME, T200, T3115,


TAADJ, TNCH, TSYNC, TSYNCD, TSYNCR, TSYNCU,
TTRAU, TUPLREP, TXDIVTSPAR, TXDIVTSEXCPT, TXSIGLEVADJ, TXSIGLEVADJC, VGSCULFT;

Command Tree:
MANAGED-ELEMENT h BSS-FUNCTIONAL h BTSM h BTS h GET BTS
TIMER

140

Id:0900d805805944a4

A50016-G5100-B333-04-7619

BS-4x / 82 II / 240 / 241 / 240XL commands

BTS

Applicability:
Phase 3.
Visibility level: 0.
Command Description:
This command displays the attributes of the BTS timer.
Long Names:
NAME

Address of the managed object

REQATTL

Required attribute list

STATIME

startingTime

T200

t200

T3115

t3115(*10ms)

TAADJ

taAdjust(microseconds)

TNCH

tNCH(*multiframes)

TSYNC

tSync(*10ms)

TSYNCD

tSyncD(*10ms)

TSYNCR

tSyncR(*10ms)

TSYNCU

tSyncU(*10ms)

TTRAU

tTrau(*10ms)

TUPLREP

timerUplinkReply

TXDIVTSPAR

txDivTimeShiftParam

TXDIVTSEXCPT
TXSIGLEVADJ

txSigLevAdjust

TXSIGLEVADJC
VGSCULFT

txDivTimeShiftExcept
txSigLevAdjustCompl

voiceGroupUplinkFree(*10ms)

System Responses:
Operation Completed
A message indicates the result of the operation. An example of get timer command is
the following:
JOB: 288
PC Time&Date: 05.05.2008 11:43:09 +02:00
NE Time&Date: 05.05.2008 11:43:11 +01:00
USER NAME:

User_f

COMMAND:
Get BTS Timer:NAME=BTS:0,REQATTL=STATIME&T200&T3115&TADDJ&TNCH&TSYNC&TSYNCD&TSYNCR&TSYNCU&TTRA
U&TUPLREP&TXDIVTSPAR&TXDIVTSEXCPT&TXSIGLEVADJ&TXSIGLEVADJC&VGSCULFT;

A50016-G5100-B333-04-7619

Id:0900d805805944a4

141

BTS

BS-4x / 82 II / 240 / 241 / 240XL commands

SW RELEASE:

01-04-19-01-86-MF_08-04-24

COMMAND RESULT: Operation successful

startingTime = 65535
t200 =
sdcchSAPIO = 44
facchTCHF = 31
facchTCHH = 41
saccchTCHSAPIO = 90
sacchSDCCH = 90
sdcchSAPI3 = 90
sacchTCHSAPI3 = 135
t3115(*10ms) = 3
taAdjust(microseconds) = 0.0
timerUplinkReply = 20
tNCH(*multiframes) = 1
tSync(*10ms) = 1000
tSyncD(*10ms) = 1000
tSyncR(*10ms) = 400
tSyncU(*10ms) = 1000
tTrau(*10ms) = 1000
txDivTimeShiftExcept = NONE
txDivTimeShiftParam = 0.00
txSigLevAdjust = Null
txSigLevAdjustCompl = Null
voiceGroupUplinkFree(*10ms) = 2
END OF OUTPUT FOR JOB 288
Operation Failed
None.
Application Guidelines:
None.
Example of Command Execution:
Get BTS Timer:NAME=BTS:0,REQATTL=STATIME&T200&T3115&TADDJ&TNCH&TSYNC&TSYNCD&TSYNCR&TSYNCU&TTRA
U&TUPLREP&TXDIVTSPAR&TXDIVTSEXCPT&TXSIGLEVADJ&TXSIGLEVADJC&VGSCULFT;

142

Id:0900d805805944a4

A50016-G5100-B333-04-7619

BS-4x / 82 II / 240 / 241 / 240XL commands

BTSEP

BTSEP
The BS240/1 consists of a base rack with up to 8 TRXs. Optionally it can be connected
to two extension racks to reach up to 24 TRX.
The BS240XL consists of a base rack with up to 12 TRXs. Optionally it can be connected
an extension rack to reach up to 24 TRXs.
The BS40/1 and BS40II consists of a base rack with up to 4 TRXs.
The BS82II consists of a base rack with up to 2 TRXs. Optionally it can be connected up
two extension rack to reach up to 6 TRXs.

DELETE BTSEP DBFILE


DELETE BTSEP
DBFILE

NAME=BTSEP:0..0;

Command Tree:
MANAGED-ELEMENT h BSS-EQUIPMENT h BTSEP h DELETE BTSEP
DBFILE
Applicability:
Phase 2.
Visibility level: 2.
Command Description:
This command deletes the data base file.
Long Names:
NAME

Address of the managed object

System Responses:
Operation Completed
The data base file has been deleted.
JOB: 55
PC Time&Date: 11:56:59 03/23/2005
NE Time&Date: 12:58:13 09/15/2004
USER NAME:

User_g

COMMAND:

Delete BTSEP DBFILE:NAME=BTSEP:0;

SW RELEASE:

01-04-17-01-26-51_05-02-23

COMMAND RESULT: Operation successful


END OF OUTPUT FOR JOB 55

A50016-G5100-B333-04-7619

Id:0900d805805944a6

143

BTSEP

BS-4x / 82 II / 240 / 241 / 240XL commands

Operation Failed
The data base file has not been deleted.
Application Guidelines:

The file related to REMINV isn't affected by the command

The command cause a restart of the BTSE and that the operator has to do a new
login afterward

All HW Objects, which were created per command, will be deleted, including
"Minimal Configuration"

All stored SW Loads will still be available

Only the DB of COBA:0 will be deleted

Example of Command Execution:


Delete BTSEP DBFILE:NAME=BTSEP:0;

FORMAT BTSEP FLASH


FORMAT BTSEP
FLASH

NAME=BTSEP:0..0;

Command Tree:
MANAGED-ELEMENT h BSS-EQUIPMENT h BTSEP h FORMAT BTSEP
FLASH
Applicability:
Phase 1 and Phase 2.
Visibility level: 3.
Dangerous
Command Description:
This command formats the Flash EPROMs of COBA (Core module). Since it is considered a "dangerous" command, a confirmation dialog will ask you to confirm or cancel the
action.
Long Names:
NAME

Address of the managed object

System Responses:
Operation Completed
The Flash EPROMs of the COBA have been formatted.
JOB: 56
PC Time&Date: 11:57:07 03/23/2005
NE Time&Date: 12:58:42 09/15/2004

144

Id:0900d805805944a6

A50016-G5100-B333-04-7619

BS-4x / 82 II / 240 / 241 / 240XL commands

BTSEP

USER NAME:

User_g

COMMAND:

Format BTSEP FLASH:NAME=BTSEP:0;

SW RELEASE:

01-04-17-01-26-51_05-02-23

COMMAND RESULT: Operation successful


END OF OUTPUT FOR JOB 56
Operation Failed
The Flash EPROMs of the COBA have not been formatted.
Application Guidelines:

The command cause a restart of the BTSE and that the operator has to do a new
login afterward

All HW Objects and all SW Loads will be deleted, complete formatting in COBA:0 if
COBA:1 is Power Off

Example of Command Execution:


Format BTSEP FLASH:NAME=BTSEP:0;

GET BTSEP NOSWL


GET BTSEP NOSWL

NAME=BTSEP:0..0 [,REQATTL=ALIGCOBA, ALRMSEVXXX, ALS, AST, AVS, CHIDT, EAUTOREC, EQUPOS,


GTWADRV4, LMTLSESS, LMTLTIME, LMTUAL, LMTUNAME, LOCNAME, OST, OVPTINS, PRS, RELFUNCOBJ,
RXDIVSV, SALUNAME, SCLPRIOLST, VENDNA];

Command Tree:
MANAGED-ELEMENT h BSS-EQUIPMENT h BTSEP h GET BTSEP NOSWL
Applicability:
Phase 2 and Phase 3.
Visibility level: 0.
Command Description:
This command displays the attributes related to the BTSE (BTS Site Equipment).
Long Names:
NAME

Address of the managed object

REQATTL

Required attribute list

ALIGCOBA

alignedCoba

ALRMSEVXXX

alarmSeverityXXX

ALS

alarmStatus

AST

administrativeState

AVS

availabilityStatus

A50016-G5100-B333-04-7619

Id:0900d805805944a6

145

BTSEP

BS-4x / 82 II / 240 / 241 / 240XL commands

CHIDT

changeOnIDT

EAUTOREC

enableAutoRecovery

EQUPOS

equipmentPosition

GTWADRV4

gatewayAddressIPv4

LMTLSESS

lmtLogonSession

LMTLTIME

lmtLogonTime

LMTUAL

lmtUserAccessLevel

LMTUNAME

lmtUserName

LOCNAME

locationName

OST

operationalState

OVPTINS

ovptInstalled

PRS

proceduralStatus

RELFUNCOBJ

relatedFuncObjects

RXDIVSV

enableRxDiversitySupervision

SALUNAME

salesUniqueName

SCLPRIOLST

serviceClassPrioList

VENDNA

vendorName

System Responses:
Operation Completed
A message indicates the result of the operation. An example of get noswl command is
the following:
JOB: 29
PC Time&Date: 30.05.2008 10:57:41 +02:00
NE Time&Date: 01.01.1990 00:02:14 +00:00
USER NAME:

User_g

COMMAND:

Get BTSEP NOSWL:NAME=BTSEP:0;

SW RELEASE:

01-04-19-01-01-ZS_08-05-29

COMMAND RESULT: Operation successful


alignedCoba = TRUE
alarmSeverityAcdcp = DEFAULT_DB
alarmSeverityAct = DEFAULT_DB
alarmSeverityCoba = DEFAULT_DB
alarmSeverityBattery = DEFAULT_DB
alarmSeverityBcomp = DEFAULT_DB
alarmSeverityCosa = DEFAULT_DB

146

Id:0900d805805944a6

A50016-G5100-B333-04-7619

BS-4x / 82 II / 240 / 241 / 240XL commands

BTSEP

alarmSeverityCu = DEFAULT_DB
alarmSeverityDidctma = DEFAULT_DB
alarmSeverityDilna = DEFAULT_DB
alarmSeverityDuamco = DEFAULT_DB
alarmSeverityDudctma = DEFAULT_DB
alarmSeverityDulna = DEFAULT_DB
alarmSeverityDuvswr = DEFAULT_DB
alarmSeverityF6dctma = DEFAULT_DB
alarmSeverityF6lna = DEFAULT_DB
alarmSeverityF6tnfp = DEFAULT_DB
alarmSeverityF6vswrp = DEFAULT_DB
alarmSeverityFanp = DEFAULT_DB
alarmSeverityFcumain = DEFAULT_DB
alarmSeverityFcutr = DEFAULT_DB
alarmSeverityFtnfp = DEFAULT_DB
alarmSeverityFvswrp = DEFAULT_DB
alarmSeverityLmu = DEFAULT_DB
alarmSeveritySdulna = DEFAULT_DB
alarmSeveritySdusec = DEFAULT_DB
alarmSeveritySdusubs = DEFAULT_DB
alarmSeveritySdutxsw = DEFAULT_DB
alarmSeverityTma = DEFAULT_DB
alarmStatus = CLEARED
administrativeState = Unlocked
availabilityStatus = NULL
changeOnIDT = IDTWasChanged
enableAutoRecovery = disabled
equipmentPosition = "010101"
gatewayAddressIPv4 = "192.168.3.20"
lmtLogonSession = ACTIVE
lmtLogonTime = 01.01.2008 00:00:17 +00:00
lmtUserAccessLevel = ACCESS_CONTROL_MANAGEMENT
lmtUserName = "User_g"
locationName = "EARTH"
operationalState = ENABLED
ovptInstalled = TRUE
proceduralStatus = NULL
relatedFuncObjects =
FMO = BTSM:0

A50016-G5100-B333-04-7619

Id:0900d805805944a6

147

BTSEP

BS-4x / 82 II / 240 / 241 / 240XL commands

enableRxDiversitySupervision = disabled
salesUniqueName = ""
serviceClassPrioList =
serviceClass = ces
vlanPrio = vPrio7
dscpClass = dCl5
dscpDropPre = dDP6
vendorName = "Nokia Siemens Networks"
END OF OUTPUT FOR JOB 29
Operation Failed
The GET command has not been successfully executed. A general NACK will indicate
possible errors or a specific NACK strictly related to the single command is possible.
Application Guidelines:

The attributes have to be set beforehand, otherwise the response will be a Nack
message

Example of Command Execution:


Get BTSEP NOSWL:NAME=BTSE:0,REQATTL=ALIGCOBA& ALRMSEVXXX&ALRMSEVBCOMP& ALRMSEVDUAMCO&ALRMSEVF6DCTMA&
ALRMSEVF6LNA&ALRMSEVF6TNFP& ALRMSEVF6VSWRP& ALS& AST&
AVS&CHIDT& EAUTOREC& EQUPOS& GTWADRV4& LMTLSESS&LMTLTIME&
LMTUAL& LMTUNAME& LOCNAME& OST&OVPTINS& PRS& RELFUNCOBJ&
RXDIVSV& SALUNAME&SCLPRL& VENDNA;

GET BTSEP SWL


GET BTSEP SWL

NAME=BTSEP:0..0 ,REQATTL=SWLDINT, SWLDSAF,


SWLDST;

Command Tree:
MANAGED-ELEMENT h BSS-EQUIPMENT h BTSEP h GET BTSEP SWL
Applicability:
Phase 2 and Phase 3.
Visibility level: 0.
Command Description:
This command displays the attributes related to the BTSE (BTS Site Equipment).
Long Names:

148

NAME

Address of the managed object

REQATTL

Required attribute list

SWLDINT

swLoadIntended

SWLDSAF

swLoadSafety

Id:0900d805805944a6

A50016-G5100-B333-04-7619

BS-4x / 82 II / 240 / 241 / 240XL commands

SWLDST

BTSEP

swLoadsStored

System Responses:
Operation Completed
A message indicates the result of the operation. An example of get swl command is the
following:
JOB: 49
PC Time&Date: 11:56:26 03/23/2005
NE Time&Date: 12:58:01 09/15/2004
USER NAME:

User_g

COMMAND:
SAF&SWLDST

Get BTSEP SWL:NAME=BTSEP:0,REQATTL=SWLDINT&SWLD-

SW RELEASE:

01-04-17-01-26-51_05-02-23

COMMAND RESULT: Operation successful


swLoadIntended = "HS011907.SWL:01-04-19-01-07-00_08-03-19"
swLoadSafety = ""
swLoadsStored =
SWLD = "HS011907.SWL:01-04-19-01-07-00_08-03-19"
SWLD = "FSFD1901.SWL:FD-04-19-00-01-00_08-01-29"
SWLD = "FSBO1910.SWL:BO-04-19-01-10-03_08-01-08"
END OF OUTPUT FOR JOB 49
Operation Failed
The GET command has not been successfully executed. A general NACK will indicate
possible errors or a specific NACK strictly related to the single command is possible.
Application Guidelines:

The attributes have to be set beforehand, otherwise the response will be a Nack
message

Example of Command Execution:


Get BTSEP SWL:NAME=BTSEP:0,REQATTL=SWLDINT&SWLDSAF&SWLDST;

GETACTIVEALARMS BTSEP
GETACTIVEALARMS
BTSEP

A50016-G5100-B333-04-7619

NAME=BTSEP:0..0 [,EVTYP=];

Id:0900d805805944a6

149

BTSEP

BS-4x / 82 II / 240 / 241 / 240XL commands

Command Tree:
MANAGED-ELEMENT h BSS-EQUIPMENT h BTSEP h GETACTIVEALARMS
BTSEP
Applicability:
Phase 2 and Phase 3.
Visibility level: 0.
Command Description:
This command is sent to the BTSE to ask for the active alarms of a certain
failure_event_type.
When a remote connection is made a warning is issued from LMT to inform you that
FER coming from BTS, TRAU and BSC are not received. This must be intended in the
sense that: spontaneous FER are not received when they are originated but active
FER on connected BTS and TRAU can be retrieved by using the command GetActiveAlarm, both from CLI and GUI LMT, present also in RemoteMode.
A Failure Event Report will be displayed, with the following attributes:
eventType

This attribute specifies the type of failure event alarm.

eventTime

It represents the time of the event.

perceivedSeverity

This attribute can assume the following values:


indeterminate
criticalFailure
majorFailure
minorFailure
warningLevelFailure
failureCeased

probableCause

This attribute indicates the probable cause of the failure.

specificProblem

It is a code that has to be referred to the 'Alarm Manual'.

trendIndication

This attribute can assume the following values:


lessSevere
noChange
moreSevere

notificationIdentifier

The range of this attribute is: 0...4294967295

correlatedNotifications

This attribute is composed by the following fields:


identifier: 0...4294967295
relatedMO: object class and object instance refer
to the source object in the father event. During
state and alarm alignment the state class BTSEP
is used.

150

Id:0900d805805944a6

A50016-G5100-B333-04-7619

BS-4x / 82 II / 240 / 241 / 240XL commands

BTSEP

thresholdInformation

This information element is only present if a threshold is


assigned to the corresponding alarm and the 'perceived
severity' is not 'failure ceased'. If no threshold is
exceeded only the observed value is valid.

additionalText

This is a string of 26 ASCII characters which are specified by the operator for the corresponding envaBTSE
instance (site input). The ASCII characters are not terminated by a NULL character

additionalInformation

This attribute specifies some additional information


(Originator value, FileVersion...)

Long Names:
NAME

Address of the managed object

EVTYP

eventType

System Responses:
Operation Completed
A message indicates the result of the operation. An example of getactivealarms
command is the following:
JOB: 50
PC Time&Date: 11:56:29 03/23/2005
NE Time&Date: 12:58:04 09/15/2004
USER NAME:

User_g

COMMAND:

Getactivealarms BTSEP:NAME=BTSEP:0;

SW RELEASE:

01-04-17-01-26-51_05-02-23

COMMAND RESULT: Operation successful


END OF OUTPUT FOR JOB 50
JOB: 51
PC Time&Date: 11:56:29 03/23/2005
NE Time&Date: 12:58:04 09/15/2004
USER NAME:

User_g

SW RELEASE:

01-04-17-01-26-51_05-02-23

COMMAND RESULT: Operation successful


START ACTIVE ALARM ALIGNMENT BTSEP:

A50016-G5100-B333-04-7619

Id:0900d805805944a6

151

BTSEP

BS-4x / 82 II / 240 / 241 / 240XL commands

name = BTSEP:0
alignmentRequestNo = 0
notificationIdentifier = 288
END OF OUTPUT FOR JOB 51
JOB: 52
PC Time&Date: 11:56:29 03/23/2005
NE Time&Date: 12:58:04 09/15/2004
USER NAME:

User_g

SW RELEASE:

01-04-17-01-26-51_05-02-23

COMMAND RESULT: Operation successful


END ACTIVE ALARM ALIGNMENT BTSEP:
name = BTSEP:0
alignmentResult = SUCCESSFUL
correlatedNotifications =
correlatedNotificationId = 288
sourceObjectInstance = BTSEP:0
END OF OUTPUT FOR JOB 52
Operation Failed
The GET command has not been successfully executed. A general NACK will indicate
possible errors or a specific NACK strictly related to the single command is possible.
Application Guidelines:
None.
Example of Command Execution:
Getactivealarms BTSEP: NAME=BTSEP:0,
EVTYP= ENVIRONMENTAL_FAILURE_EVENT;

PERFTEST BTSEP
PERFTEST BTSEP

NAME=BTSEP:0..0 ,MORT=;

Command Tree:
MANAGED-ELEMENT h BSS-EQUIPMENT h BTSEP h PERFTEST BTSEP

152

Id:0900d805805944a6

A50016-G5100-B333-04-7619

BS-4x / 82 II / 240 / 241 / 240XL commands

BTSEP

Applicability:
Phase 2 and Phase 3.
Visibility level: 1.
Command Description:
This command displays the attributes related to the BTSE (BTS Site Equipment).
Long Names:
NAME

Address of the managed object

MORT

MOT

System Responses:
Operation Completed
Test configuration has been set and the specified test has been started. The System
response will not be addressed to the MOT but to the object BTSEP
JOB: 55
PC Time&Date: 11:56:59 03/23/2005
NE Time&Date: 12:59:48 09/15/2004
USER NAME:

User_g

COMMAND:

Perftest BTSEP:NAME=BTSEP:0,MORT=RACK:0;

SW RELEASE:

01-04-17-01-26-51_05-02-23

COMMAND RESULT: Operation successful


MOT = BTSEP:0,MORT=RACK:0;
tO = BTSETEST:1
END OF OUTPUT FOR JOB 55
JOB: 56
PC Time&Date: 11:57:07 03/23/2005
NE Time&Date: 12:58:42 09/15/2004
USER NAME:

User_g

SW RELEASE:

01-04-17-01-26-51_05-02-23

COMMAND RESULT: Operation successful


ChangedConfigurationNotification:

A50016-G5100-B333-04-7619

Id:0900d805805944a6

153

BTSEP

BS-4x / 82 II / 240 / 241 / 240XL commands

name = BTSETEST:1
ChangeInfo = created
END OF OUTPUT FOR JOB 56
JOB: 57
PC Time&Date: 11:57:14 03/23/2005
NE Time&Date: 12:58:49 09/15/2004
USER NAME:

User_g

SW RELEASE:

01-04-17-01-26-51_05-02-23

COMMAND RESULT: Operation successful


CHANGED STATE EVENT REPORT:
NAME = BTSEP:0,MORT=RACK:0;
Availability Status = Failed
Notification Identifier = 22
END OF OUTPUT FOR JOB 57
JOB: 58
PC Time&Date: 11:57:24 03/23/2005
NE Time&Date: 12:58:59 09/15/2004
USER NAME:

User_g

SW RELEASE:

01-04-17-01-26-51_05-02-23

COMMAND RESULT: Operation successful


Test Report:
name = BTSETEST:1
testOutcome = FAILED
testTermination = Normal
MOT = BTSEP:0,MORT=RACK:0;
executedPhases =
PreliminaryTestsBtsep

154

Id:0900d805805944a6

A50016-G5100-B333-04-7619

BS-4x / 82 II / 240 / 241 / 240XL commands

BTSEP

BootEepromTestBtsep
SerialEepromTestBtsep
EndTestBtsep
END OF OUTPUT FOR JOB 58
JOB: 59
PC Time&Date: 11:57:24 03/23/2005
NE Time&Date: 12:58:59 09/15/2004
USER NAME:

User_g

SW RELEASE:

01-04-17-01-26-51_05-02-23

COMMAND RESULT: Operation successful


ChangedConfigurationNotification:
name = BTSETEST:1
ChangeInfo = deleted
END OF OUTPUT FOR JOB 59
The test results will be displayed at the end of the test phases.
Result TEST:

A50016-G5100-B333-04-7619

name =

TEST:<n>

testOutcome =

This field represents the test result; one of the following values can be displayed:
Pass

all the test phases are successfully


performed.

Inconclusive

the test is aborted by the system or


the test is terminated by the operator.

Fail

if at least one of the executed phases


fail.

mOts =

It is the identifier of the hardware object under test.

testTermination =

It specifies how the test is terminated, it can assume


the following values:
Normal

all the test phases are performed.

Abort

the test is aborted by system.

Cancel

the test is terminated by operator.

Id:0900d805805944a6

155

BTSEP

BS-4x / 82 II / 240 / 241 / 240XL commands

executedPhases
phaseId =
additionalWords =
....

It represents the list of the executed test phases (in


case of successful test result, all the test phases will
be listed).

failedPhases
phaseId =

It represents the list of the failed test phase; additional information is provided for each phase.

phaseId =
....
skippedPhases
phaseId =

It represents the list of the skipped phases; they are


displayed only for test stopped during it execution.

phaseId =
....
poprosedRepair Action
=

A list of most probable fail probable causes is shown


(max four messages)

Operation Failed
This NACK-message occurs in the following cases: Message cannot be performed, test
not supported, capacity restrictions, physical configuration cannot be performed, object
not locked.
Application Guidelines:

In phase 3 MO must be locked previous to the command execution

Example of Command Execution:


Perftest BTSEP:NAME=BTSEP:0,MORT=RACK:0/ACDCP:0;

PING BTSEP
PING BTSEP

NAME=BTSEP:0..0 ,IPADR=;

Command Tree:
MANAGED-ELEMENT h BSS-EQUIPMENT h BTSEP h PING BTSEP
Applicability:
Phase 2 and Phase 3.
Visibility level: 0.
Command Description:
The command is used to ping the BTSE.
After command execution the IP sends a response containing the following information:
-

156

IP address
of the target

Id:0900d805805944a6

A50016-G5100-B333-04-7619

BS-4x / 82 II / 240 / 241 / 240XL commands

BTSEP

alive
=TRUE/FAL
SE

Long Names:
NAME

Address of the managed object

IPADR

ipAddress

System Responses:
Operation Completed
A message indicates the result of the operation. An example of ping command is the following:
JOB: 60
PC Time&Date: 21.08.2008 13:43:00 +02:00
NE Time&Date: 21.08.2008 13:32:30 +01:00
USER NAME:

User_g

COMMAND:

Ping BTSEP:NAME=BTSEP:0,IPADR="192.168.3.25";

SW RELEASE:

01-04-19-01-12-ZT_08-08-20

COMMAND RESULT: Operation successful

hostReachable = HOST_REACHABLE
ipAddress = "192.168.3.25"
END OF OUTPUT FOR JOB 60
Operation Failed
None.
Application Guidelines:
None.
Example of Command Execution:
Ping BTSEP:NAME=BTSEP:0,IPADR="192.168.3.25";

SET BTSEP
SET BTSEP

A50016-G5100-B333-04-7619

NAME=BTSEP:0..0 [,ALIGCOBA=] [,ALRMSEVXXX=]


[,CHIDT=] [,EAUTOREC=] [,EQUPOS=] [,GTWADRV4=]
[,LOCNAME=] [,OVPTINS=] [,RXDIVSV=] [,SALUNAME=]
[,SCLPRIOLST=] [,SWLDSAF=] [,VENDNA=];

Id:0900d805805944a6

157

BTSEP

BS-4x / 82 II / 240 / 241 / 240XL commands

Command Tree:
MANAGED-ELEMENT h BSS-EQUIPMENT h BTSEP h SET BTSEP
Applicability:
Phase 2 and Phase 3.
Visibility level: 2.
Command Description:
This command sets general attributes of the BTS Site Equipment (BTSE). A BTSE is the
physical equipment which is managed by one BTSM.
Long Names:
NAME

Address of the managed object

ALIGCOBA

alignedCoba

ALRMSEVXXX

alarmSeverityXXX

CHIDT

changeOnIDT

EAUTOREC

enableAutoRecovery

EQUPOS

equipmentPosition

GTWADRV4

gatewayAddressIPv4

LOCNAME

locationName

OVPTINS

ovptInstalled

RXDIVSV

enableRxDiversitySupervision

SALUNAME

salesUniqueName

SCLPRIOLST

serviceClassPrioList

SWLDSAF

swLoadSafety

VENDNA

vendorName

System Responses:
Operation Completed
After command execution, a message of Changed Attribute Event Report is displayed.
A further message indicates the result of the operation. An example of set command is
the following:
JOB: 19
PC Time&Date: 13.03.2008 13:28:24 +01:00
NE Time&Date: 01.01.1990 00:03:37 +00:00
USER NAME:

User_g

COMMAND:

Set BTSEP:NAME=BTSEP:0,GTWADRV4="192.168.5.100/24";

SW RELEASE:

01-04-19-01-06-03_08-03-11

COMMAND RESULT: Operation successful

158

Id:0900d805805944a6

A50016-G5100-B333-04-7619

BS-4x / 82 II / 240 / 241 / 240XL commands

BTSEP

gatewayAddressIPv4 = "192.168.5.100/24"
END OF OUTPUT FOR JOB 19
Operation Failed
The specified attributes have not been set. In addition to the general NACK causes, a
specific NACK cause, which indicates that the command is inconsistent with the
physical configuration, is possible.
Application Guidelines:

The supplier recommends the identification of swLoadSafety

The swLoadSafety will not be overwritten by a sw download via LMT Evolution

There is no alignment to one of the SW loads stored on the BSC master database

The swLoad must be stored in BTSE and must have at least once a connection with
the BSC

The identification of a SW load as the safety one is only accepted by the BTSE if the
identified load has been activated and running on this BTSE before

An update of the swLoadSafety attribute should be performed in each release; the


swLoad of the previous release should be used as swLoadSafety

Example of Command Execution:


Set BTSEP :NAME=BTSEP:0,Set BTSEP:NAME=BTSEP:0,ALRMSEVACDCP=CRITICAL,ALRMSEVACT=CRITICAL,ALRMSEVBATTERY=CRITICAL,ALRMSEVBCOMP=CRITICAL,ALRMSEVCOBA=CRITICAL,ALRMSEVCOSA=CRITICAL,ALRMS
EVCU=CRITICAL,ALRMSEVDIDCTMA=CRITICAL,ALRMSEVDILNA=CRITICAL,ALRMSEVDUAMCO=CRITICAL,ALRMSEVDUDCTMA=CRITICAL,ALRMSEVDULNA=CRITICAL,ALRMSEVDUVSWR=CRITICAL,ALRMSEVF6DCTMA=CRITI
CAL,ALRMSEVF6LNA=CRITICAL,ALRMSEVF6TNFP=CRITICAL,ALRMSEVF6VSWRP=CRITICAL,ALRMSEVFANP=CRITICAL,ALRMSEVFCUMAIN=CRITICAL,ALRMSEVFCUTR=CRITICAL,ALRMSEVFTNFP=CRITICAL,ALRM
SEVFVSWRP=CRITICAL,ALRMSEVLMU=CRITICAL,ALRMSEVSDULNA=CRITICAL,ALRMSEVSDUSEC=CRITICAL,ALRMSEVSDUSUBS=CRITICAL,ALRMSEVSDUTXSW=CRITICAL,ALRMSEVTMA=CRITICAL,EQUPOS="020101",CHIDT=noCha
ngeOnIDT,
EAUTOREC=disabled,LOCNAME="MUNICH",OVPTINS=true,RXDIVSV=enabled,
SALUNAME="AD042S7449E",SWLDSAF="HS011726.SWL:02-04-17-01-13-00_0409-03",VENDNA="Nokia Siemens Networks";

STOPTEST BTSEP
STOPTEST BTSEP

NAME=BTSEP:0..0 [,MORT=] [,TESTNO=];

Command Tree:
MANAGED-ELEMENT h BSS-EQUIPMENT h BTSEP h STOPTEST BTSEP
Applicability:
Phase 2 and Phase 3.

A50016-G5100-B333-04-7619

Id:0900d805805944a6

159

BTSEP

BS-4x / 82 II / 240 / 241 / 240XL commands

Visibility level: 1.
Command Description:
This command requires the stop of the test on BTSE Plus.
Long Names:
NAME

Address of the managed object

MORT

MOT

TESTNO

testNo

System Responses:
Operation Completed
Test has been stopped.
Operation Failed
Test has not been stopped. This NACK-message can occur
when the specified test is not running or in case of test which
cannot be stopped.
TEST REPORT:

The TEST REPORT provides a list of executed, failed and


skipped phases.

Application Guidelines:
None.
Example of Command Execution:
Stoptest BTSEP:NAME=BTSEP:0, MORT=RACK:0/ACDCP:0,TESTNO=23;

160

Id:0900d805805944a6

A50016-G5100-B333-04-7619

BS-4x / 82 II / 240 / 241 / 240XL commands

BTSETEST

BTSETEST
The TEST locates a test object in the system; this object is created when an activation
of a diagnostic occurs.

GET BTSETEST
GET BTSETEST

NAME=BTSETEST:1..255 [,REQATTL=MORT, TESTMON,


TESTOUT, TESTST];

Command Tree:
MANAGED-ELEMENT h BSS-EQUIPMENT h BTSEP h BTSETEST h GET
BTSETEST
Applicability:
Phase 2 and Phase 3.
Visibility level: 0.
Command Description:
This command displays the attributes related to a test. The values 1-255 will be used for
the allocated 'test object instance' to keep track of the related 'MORTs'.
Long Names:
NAME

Address of the managed object

REQATTL

Required attribute list

MORT

MOT

TESTMON

testMonitor

TESTOUT

testOutcome

TESTST

testState

System Responses:
Operation Completed
The output includes a test report containing "Executed Phases", "Failed Phases", "TestOutcome", "Test Termination", "MOT". An example of "Test Report" is the following:
JOB: 19
PC Time&Date: 11:32:14 03/23/2005
NE Time&Date: 11:30:55 09/15/2004
USER NAME:

User_NSN

SW RELEASE:

01-04-17-01-26-51_05-02-23

COMMAND RESULT: Operation successful


Test Report BTSETEST:

A50016-G5100-B333-04-7619

Id:0900d805805944a8

161

BTSETEST

BS-4x / 82 II / 240 / 241 / 240XL commands

name = BTSETEST:1
testOutcome = PASSED
testTermination = Normal
MOT = RACK:0/CU:2
executedPhases =
PreliminaryTestsAct
CheckAlarmStatusAct
EndTestAct
END OF OUTPUT FOR JOB 19
Operation Failed
The GETTEST command has not been successfully executed.
A general NACK will indicate possible errors or a specific NACK strictly related to the
single command is possible.
Application Guidelines:

Only intrusive tests are supported

For TESTOUT attribute the value inconclusive is possible only during the start
phase. It indicates that no "Pass" or "Fail" outcome has been determined yet

Example of Command Execution:


Get BTSETEST :NAME=BTSETEST:1,REQATTL=MORTS&TESTMON&TESTOUT&TESTST;

162

Id:0900d805805944a8

A50016-G5100-B333-04-7619

BS-4x / 82 II / 240 / 241 / 240XL commands

BTSM

BTSM
The BTSM object provides services to control the functionalities of one or more BTSs
located at the same site. It performs all the operation and maintenance functions
common to all transceivers.

ACTIVATE BTSM
ACTIVATE BTSM

NAME=BTSM:0..0 ,FILEID= ,FILESWV=;

Command Tree:
MANAGED-ELEMENT h BSS-FUNCTIONAL h BTSM h ACTIVATE BTSM
Applicability:
Phase 1 and Phase 2.
Visibility level: 2.
Command Description:
This command activates one of the three SW loads stored in the BTSE.
Long Names:
NAME

Address of the managed object

FILEID

fileId

FILESWV

fileVersion

System Responses:
Operation Completed
Download START:
JOB: 181
PC Time&Date: 12:06:21 03/23/2005
NE Time&Date: 13:07:57 09/15/2004
USER NAME:

User_NSN

COMMAND:
Activate BTSM:NAME=BTSM:0,FILEID="HS011726.SWL:01-04-1601-59-00_03-11-18";
SW RELEASE: 01-04-17-01-26-51_05-02-23
COMMAND RESULT: Operation successful
fileId = "HS011722.SWL"
fileVersion = "01-04-17-01-26-51_05-02-23"
END OF OUTPUT FOR JOB 181

A50016-G5100-B333-04-7619

Id:0900d805805944aa

163

BTSM

BS-4x / 82 II / 240 / 241 / 240XL commands

JOB: 182
PC Time&Date: 12:06:21 03/23/2005
NE Time&Date: 13:07:57 09/15/2004
USER NAME:

User_NSN

SW RELEASE:

01-04-17-01-26-51_05-02-23

COMMAND RESULT: Operation successful


ID_Message
END OF OUTPUT FOR JOB 182

SW ACTIVATED REPORT:
(a report is displayed)
Operation Failed
(Invalid SVR)
Application Guidelines:

If an incorrect FileVersion is given the system rejects the command

This command is followed by a reset of the BTSE

If the currently running SW version is activated by the command, the SW will be distributed again in the BTSE

If the intended SW is corrupted, the BTSE first tries to come up with the safety load;
if this is not successful, the BTSE tries to start the third SWload, the dischargeable
one

The FileId is a parameter used within the SW download procedures and not of the
type 'GET'. The corresponding attribute is SWLCFID and is related only to the
swLoad-header file. All characters of the ASCII string are to be in upper case.
However, the SW parts in the BTSE handling the file Id are to be case tolerant

The FileVersion is a parameter used within the SW download procedures and not of
the type 'GET'. The corresponding attribute is SWLCVER which is coded identical
as File Version. However the allowed values for 'hh' are different because
SWLCVER is related only to the swLoad-header file

Recent BTS SW productions expect 64M RAM, the SW doesn't work with old
CESCOBA

Example of Command Execution:


Activate BTSM:NAME=BTSM:0,FILEID="vHS011722.SWL",FILESWV="02-04-16-0105-01_03_02_25"

164

Id:0900d805805944aa

A50016-G5100-B333-04-7619

BS-4x / 82 II / 240 / 241 / 240XL commands

BTSM

ACTIVATE_DELAYED BTSM
ACTIVATE_DELAYED
BTSM

NAME=BTSM:0..0 ,FILEID= ,FILESWV= ,TIMEDELAY=;

Command Tree:
MANAGED-ELEMENT h BSS-FUNCTIONAL h BTSM h ACTIVATE_DELAYED
BTSM
Applicability:
Phase 2.
Visibility level: 2.
Command Description:
This command activates one of the three SW loads stored in the BTSE with a defined
delayed time.
Long Names:
NAME

Address of the managed object

FILEID

fileId

FILESWV

fileVersion

TIMEDELAY

timeDelay(sec)

System Responses:
Operation Completed
USER NAME:

User_NSN

COMMAND:
Activate_delayed BTSM:NAME=BTSM:0,FILEID="123456789123",FILESWV="01-01-16-00-56-00_03-10-16",TIMEDELAY=3;
SW RELEASE:

01-01-17-00-26-51_05-02-23

COMMAND RESULT: Operation successful


Operation Failed
None.
Application Guidelines:
None.
Example of Command Execution:
Activate_delayed BTSM:NAME=BTSM:0,FILEID="123456789123",FILESWV="01-0116-00-56-00_03-10-16",TIMEDELAY=3;

CONNBSC BTSM
CONNBSC BTSM

NAME=BTSM:0..0;

Command Tree:
MANAGED-ELEMENT h BSS-FUNCTIONAL h BTSM h CONNBSC BTSM

A50016-G5100-B333-04-7619

Id:0900d805805944aa

165

BTSM

BS-4x / 82 II / 240 / 241 / 240XL commands

Applicability:
Phase 2.
Visibility level: 1.
Command Description:
This command starts the connection between BTS and BSC and is followed by a transition from LMT Phase 2 to LMT Phase 3.
Long Names:
NAME

Address of the managed object

System Responses:
Operation Completed
The command has been correctly executed.
JOB: 180
PC Time&Date: 12:06:20 03/23/2005
NE Time&Date: 00:00:00 00/00/0
USER NAME:

User_NSN

COMMAND:

Connbsc BTSM:NAME=BTSM:0;

SW RELEASE:

01-04-17-01-26-51_05-02-23

COMMAND RESULT: Operation successful


END OF OUTPUT FOR JOB 180

SWACTIVATED REPORT
Operation Failed
The command has not been correctly executed.
Application Guidelines:

166

After the execution of this command, the BTSM will be in the administrative state
"Unlocked"

If one of the "Minimal Parameters" of the BTSE is in the locked state, no connection
to the BSC is possible

The CCLK accuracy must be "Medium" or "High" before the connection to the BSC
is possible

The BTSM attribute TEI has to be defined

The BPORT object has to be defined previous LAPDLE

The LAPDLE object has to be defined

Id:0900d805805944aa

A50016-G5100-B333-04-7619

BS-4x / 82 II / 240 / 241 / 240XL commands

BTSM

For OMC purposes the Attributes SALUNAME and TYPRACK have to be set. Otherwise the OMC cannot identify the BTSE

Example of Command Execution:


Connbsc BTSM:NAME=BTSM:0;

DISCBSC BTSM
DISCBSC BTSM

NAME=BTSM:0..0;

Command Tree:
MANAGED-ELEMENT h BSS-FUNCTIONAL h BTSM h DISCBSC BTSM
Applicability:
Phase 3.
Visibility level: 1.
Command Description:
This command disconnects the BTS from the BSC and is followed by a transition from
LMT Phase 3 to LMT Phase 2.
Long Names:
NAME

Address of the managed object

System Responses:
Operation Completed
The command has been correctly executed.
JOB: 179
PC Time&Date: 12:06:20 03/23/2005
NE Time&Date: 00:00:00 00/00/0
USER NAME:

User_NSN

COMMAND:

Discbsc BTSM:NAME=BTSM:0;

SW RELEASE:

01-04-17-01-26-51_05-02-23

COMMAND RESULT: Operation successful


END OF OUTPUT FOR JOB 179
Operation Failed
The command has not been correctly executed.

A50016-G5100-B333-04-7619

Id:0900d805805944aa

167

BTSM

BS-4x / 82 II / 240 / 241 / 240XL commands

Application Guidelines:

If a connection to the BSC is established, the BTSM must be in the administrative


state "Locked"

If the SW in BTSM in BSC is not the same like in BTSE, BTSM cannot be locked
(At BSC disk no SW is available) and the user cannot come to Phase 2. To come to
phase 2, execute a COBA manual reset.

Example of Command Execution:


Discbsc BTSM:NAME=BTSM:0;

FWUPGRADE BTSM
FWUPGRADE BTSM

NAME=BTSM:0..0 ,FILEID= ,FILEFWV= [,LRU=] [,ACTVINC=];

Command Tree:
MANAGED-ELEMENT h BSS-FUNCTIONAL h BTSM h FWUPGRADE BTSM
Applicability:
Phase 2 and Phase 3.
Visibility level: 2.
Command Description:
This command is used to initiate the firmware upgrade.
Long Names:
NAME

Address of the managed object

FILEID

fileId

FILEFWV

fwVersion

LRU

lru

ACTVINC

activationIncluded

System Responses:
Operation Completed
After command execution, a message of Changed Configuration Notification is displayed.
A further message indicates the result of the operation. An example of fwupgrade
command is the following:
JOB: 62
PC Time&Date: 26.03.2008 13:23:37 +01:00
NE Time&Date: 01.01.1990 00:08:35 +00:00
USER NAME:

168

User_NSN

Id:0900d805805944aa

A50016-G5100-B333-04-7619

BS-4x / 82 II / 240 / 241 / 240XL commands

BTSM

COMMAND:
FwUpgrade BTSM:NAME=BTSM:0,ACTVINC=TRUE,FILEFWV="BU04-19-00-01-15_08-01-29",FILEID="FSBU1901.SWL";
SW RELEASE:

01-04-19-01-07-00_08-03-19

COMMAND RESULT: Operation successful

fileId = "FSBU1901.SWL"
fwVersion = "BU-04-19-00-01-15_08-01-29"
activationIncluded = TRUE
END OF OUTPUT FOR JOB 62
Operation Failed
None.
Application Guidelines:
None.
Example of Command Execution:
FwUpgrade BTSM:NAME=BTSM:0,ACTVINC=TRUE,FILEFWV="BU-04-19-00-0115_08-01-29",FILEID="FSBU1901.SWL",LRU=HwP-Fcumain-0;

GET BTSM NOSWL


GET BTSM NOSWL

NAME=BTSM:0..0 [,REQATTL=ABISLKSAT, ABISTIME,


ASUBLKSAT, AST, AVS, DYNTRACGRAN, EINTSITSYN,
EMT1, EMT2, LPDLMSAT, OMLAPDRT, OST, RELEQUIPOBJ, TEI, TSLPOOL, SHLAPDIT];

Command Tree:
MANAGED-ELEMENT h BSS-FUNCTIONAL h BTSM h GET BTSM NOSWL
Applicability:
Phase 2 and Phase 3.
Visibility level: 0.
Command Description:
This command displays the attributes related to the BTSM (BTS Site Manager).
Long Names:
NAME

Address of the managed object

REQATTL

Required attribute list

ABISLKSAT

sAbisLinkSatellited

ABISTIME

sAbisExternalTime

ASUBLKSAT

sAsubLinkSatellited

AST

administrativeState

A50016-G5100-B333-04-7619

Id:0900d805805944aa

169

BTSM

BS-4x / 82 II / 240 / 241 / 240XL commands

AVS

availabilityStatus

DYNTRACGRAN

dynTraceGranularity

EINTSITSYN

enableInterSiteSync

EMT1

emergencyTimer1(min)

EMT2

emergencyTimer2(min)

LPDLMSAT

lapdleLinkSatellited

OMLAPDRT

omLapdRelTimer(sec)

OST

operationalState

RELEQUIPOBJ

relatedEquipObjects

TEI

tei

TSLPOOL

tslPool

SHLAPDIT

shortLapdIntTimer(sec)

System Responses:
Operation Completed
A message indicates the result of the operation. An example of get noswl command is
the following:
JOB: 20
PC Time&Date: 11:33:34 03/23/2005
NE Time&Date: 11:31:25 09/15/2004
USER NAME:

User_NSN

COMMAND:

Get BTSM NOSWL:NAME=BTSM:0;

SW RELEASE:

01-04-17-01-26-51_05-02-23

COMMAND RESULT: Operation successful

administrativeState = Unlocked
availabilityStatus = NULL
dynTraceGranularity = 1
emergencyTimer1(min) = 10
emergencyTimer2(min) = 0
enableInterSiteSync = FALSE
lapdleLinkSatellited = terrestrialConnection
omLapdRelTimer(sec) = 30
operationalState = ENABLED
relatedEquipObjects =
HMO = BTSEP:0
sAbisExternalTime =

170

Id:0900d805805944aa

A50016-G5100-B333-04-7619

BS-4x / 82 II / 240 / 241 / 240XL commands

BTSM

Year = 2003
Month = Jan
Day = 1
Hour = 20
Minute = 16
Second = 3
sAbisLinkSatellited = terrestrialConnection
sAsubLinkSatellited = terrestrialConnection
shortLapdIntTimer(sec) = 15
tei = 0
JOB: 20
tslPool =
TS01 TS02 TS03 TS04 TS05 TS06 TS07 TS08
TS09 TS10 TS11 TS12 TS13 TS14 TS15 TS16
TS17 TS18 TS19 TS20 TS21 TS22 TS23 TS24
TS25 TS26 TS27 TS28 TS29 TS30 TS31
BPORT0
0000 0000 0000 0000 1111 1111 0000 0000
0000 0000 0000 0000 0000 0000 0000 0000
0000 0000 0000 0000 0000 0000 0000 0000
0000 0000 0000 0000 0000 0000 0000
END OF OUTPUT FOR JOB 23
Operation Failed
The GET command has not been successfully executed. A general NACK will indicate
possible errors or a specific NACK strictly related to the single command is possible.
Application Guidelines:

In order to decide whether a "fast" alignment instead of a "full" one must be started,
the BSC reads the shortLAPDIntTimer and increases it of a value currently fixed to
30 seconds; for this reason the suggested values are

shortLAPDIntTimer:

max. attribute length for attribute tslPool increased to 136

Example of Command Execution:


Get BTSM NOSWL:NAME=BTSM:0,REQATTL=ABISLKSAT&ABISTIME&
AST&ASUBLKSAT&AVS&DYNTRACGRAN&EMT1&EMT2&EINTSITSYN&
LPDLMSAT&OMLAPDRT&OST&RELEQUIPOBJ&SHLAPDIT&TEI&TSLPOOL;

A50016-G5100-B333-04-7619

Id:0900d805805944aa

171

BTSM

BS-4x / 82 II / 240 / 241 / 240XL commands

GET BTSM OVERLOAD


GET BTSM OVERLOAD NAME=BTSM:0..0 ,REQATTL=LAPDOVLTH, LAPDOVLT,
LAPDOVLTRXL;
Command Tree:
MANAGED-ELEMENT h BSS-FUNCTIONAL h BTSM h GET BTSM
OVERLOAD
Applicability:
Phase 2 and Phase 3.
Visibility level: 0.
Command Description:
This command displays the attributes related to the BTSM (BTS Site Manager).
Long Names:
NAME

Address of the managed object

REQATTL

Required attribute list

LAPDOVLTH

lapdOverloadThresholds(%)

LAPDOVLT

lapdOverloadTimer(sec)

LAPDOVLTRXL

lapdOverloadTRXList

System Responses:
Operation Completed
A message indicates the result of the operation. An example of get overload command
is the following:
JOB: 5363
PC Time&Date: 30.11.2006 15:59:16 +01:00
NE Time&Date: 30.11.2006 14:59:07 +00:00
USER NAME:

User_NSN

COMMAND:
Get BTSM OVERLOAD:NAME=BTSM:0,REQATTL=LAPDOVLTH&LAPDOVLT&LAPDOVLTRXL;
SW RELEASE:

01-01-18-00-11-00_06-10-03

COMMAND RESULT: Operation successful


lapdOverloadTimer(sec) =
lapdOverloadTimer = 10
lapdUsageOverloadTimer = 0.5
lapdOverloadThresholds(%) =
firstLevUpperThreshold = 80

172

Id:0900d805805944aa

A50016-G5100-B333-04-7619

BS-4x / 82 II / 240 / 241 / 240XL commands

BTSM

firstLevLowerThreshold = 70
firstLevReductionStep = 10
secLevUpperThreshold = 90
secLevLowerThreshold = 80
lapdOverloadTRXList =
END OF OUTPUT FOR JOB 5363
Operation Failed
The GET command has not been successfully executed. A general NACK will indicate
possible errors or a specific NACK strictly related to the single command is possible.
Application Guidelines:

Number of possible TRX instances for attribute lapdOverloadTrxList increased to 48

Example of Command Execution:


Get BTSM OVERLOAD:NAME=BTSM:0,REQATTL=LAPDOVLT&LAPDOVLTH&
LAPDOVLTRXLL;

GET BTSM SWL


GET BTSM SWL

NAME=BTSM:0..0 ,REQATTL=SWLCFID, SWLCVER,


SBSCSLCV;

Command Tree:
MANAGED-ELEMENT h BSS-FUNCTIONAL h BTSM h GET BTSM SWL
Applicability:
Phase 2 and Phase 3.
Visibility level: 0.
Command Description:
This command displays the attributes related to the BTSM (BTS Site Manager).
Long Names:
NAME

Address of the managed object

REQATTL

Required attribute list

SWLCFID

swLoadCurrentFileId

SWLCVER

swLoadCurrentFileVersion

SBSCSLCV

superordinateBscSwLoadCurrentVersion

System Responses:
Operation Completed
After command execution, a message of Changed Configuration Notification is displayed. A further message indicates the result of the operation. An example of get swl
command is the following:

A50016-G5100-B333-04-7619

Id:0900d805805944aa

173

BTSM

BS-4x / 82 II / 240 / 241 / 240XL commands

JOB: 178
PC Time&Date: 12:06:19 03/23/2005
NE Time&Date: 13:03:28 09/15/2004
USER NAME:

User_NSN

COMMAND:

Get BTSM SWL:NAME=BTSM:0,REQATTL=SBSCSLCV;

SW RELEASE:

01-04-17-01-26-51_05-02-23

COMMAND RESULT: Operation successful

superordinateBscSwLoadCurrentVersion = "02-08-01-01-00-30_04-12-14"
swLoadCurrentFileId = "hs011713.SWL"
swLoadCurrentFileVersion = "01-04-17-01-26-51_05-02-23"

END OF OUTPUT FOR JOB 178


Operation Failed
The GET command has not been successfully executed. A general NACK will indicate
possible errors or a specific NACK strictly related to the single command is possible.
Application Guidelines:
None.
Example of Command Execution:
Get BTSM SWL:NAME=BTSM:0,SBSCSLCV&SWLCFID&SWLCVER;

LOCKREQUEST BTSM
LOCKREQUEST BTSM NAME=BTSM:0..0;
Command Tree:
MANAGED-ELEMENT h BSS-FUNCTIONAL h BTSM h LOCKREQUEST BTSM
Applicability:
Phase 3.
Visibility level: 1.
Command Description:
This command sends a request to the BSC for immediate locking of the BTSM.
Long Names:
NAME

174

Address of the managed object

Id:0900d805805944aa

A50016-G5100-B333-04-7619

BS-4x / 82 II / 240 / 241 / 240XL commands

BTSM

System Responses:
Operation Completed
The specified change of administrative state has been perfomed.
JOB: 56
PC Time&Date: 11:57:07 03/23/2005
NE Time&Date: 12:58:42 09/15/2004
USER NAME:

User_NSN

COMMAND:

Lockrequest BTSM:NAME=BTSM:0;

SW RELEASE:

01-04-17-01-26-51_05-02-23

COMMAND RESULT: Operation successful


END OF OUTPUT FOR JOB 56

CHANGED STATE EVENT REPORT:


This provides information about the administrative state, the operational state and the
availability status every time a state change occurs.
Operation Failed
The specified change of administrative state has not been performed.
Application Guidelines:

This command should only be used when the system is in real danger. The
Shutdown command is preferred

Example of Command Execution:


Lockrequest BTSM:NAME=BTSM:0;

SET BTSM
SET BTSM

NAME=BTSM:0..0 [,ABISLKSAT=] [,ABISTIME=] [,TEI=];

Command Tree:
MANAGED-ELEMENT h BSS-FUNCTIONAL h BTSM h SET BTSM
Applicability:
Phase 2.
Visibility level: 2.
Command Description:
This command sets the attributes of the BTS_Site_Manager (BTSM). The BTS Site
Manager represents the O&M functionality related to a site and not to any specific BTS.

A50016-G5100-B333-04-7619

Id:0900d805805944aa

175

BTSM

BS-4x / 82 II / 240 / 241 / 240XL commands

A site is a logical grouping of one or more BTS at a single physical location with common
management needs. This configuration has to match with the related LPDLM-Object in
the BSC.
Long Names:
NAME

Address of the managed object

ABISLKSAT

sAbisLinkSatellited

ABISTIME

sAbisExternalTime

TEI

tei

System Responses:
Operation Completed
After command execution, a message of Changed Attribute Event Report is displayed.
A further message indicates the result of the operation. An example of set command is
the following:
JOB: 177
PC Time&Date: 12:06:04 03/23/2005
NE Time&Date: 13:07:40 09/15/2004
USER NAME:

User_NSN

COMMAND:

Set BTSM:NAME=BTSM:0;

SW RELEASE:

01-04-17-01-26-51_05-02-23

COMMAND RESULT: Operation successful


END OF OUTPUT FOR JOB 177
Operation Failed
The specified attributes have not been set. In addition to the general NACK causes, a
specific NACK cause, which indicates that the command is inconsistent with the
physical configuration, is possible.
Application Guidelines:

176

TEI is a prerequisite for establishing the connection to the BSC

The BPortNumber must be the same for all abisChannel attributes of the CHAN
instances of the same TRX

Without defining TEI the transition from Phase 2 to Phase 3 is not possible. They are
two of the "Minimal Parameters" of the BTSE

TEI has to have the same value on BTS and on BSC (LPDLM)

If, for TEI, the signalling time slot is correct, but one side has a wrong TEI configured
the layer 2 will be established, and a related message will be received that the TEI
is wrong. Additionally, link disconnection without locking the BTSM is permitted

Id:0900d805805944aa

A50016-G5100-B333-04-7619

BS-4x / 82 II / 240 / 241 / 240XL commands

BTSM

Except for timeslot 0 (Synchronization Time Slot) all time slots can be used to
support both, traffic or signalling channels

The ABISTIME attribute is useful for longer operation on site. In transition from
Phase 2 to Phase 3 this attribute is overwritten by the BSC.

Setting of ABISLKSAT in the BTSE and of LPDLMSAT in BSC must be homogenous:


- terrestrialConnection (corresponds in the BSC to 'LPDLMSAT=FALSE')
- satelliteConnection (corresponds in the BSC to 'LPDLMSAT=TRUE')

Example of Command Execution:


Set BTSM:NAME=BTSM:0,ABISLKSAT=terrestrialConnection,
ABISTIME=1999-Oct-28-18-0-0,TEI=0;

SHUTDOWN BTSM
SHUTDOWN BTSM

NAME=BTSM:0..0;

Command Tree:
MANAGED-ELEMENT h BSS-FUNCTIONAL h BTSM h SHUTDOWN BTSM
Applicability:
Phase 3.
Visibility level: 1.
Command Description:
This command will not allow new telecom traffic to be transferred to the BTSM (no
incoming handover, no paging, no call set up). When all calls are terminated, the transfer
to "Locked" will be performed automatically.
Long Names:
NAME

Address of the managed object

System Responses:
Operation Completed
The specified change of administrative state has been perfomed.
JOB: 59
PC Time&Date: 11:57:24 03/23/2005
NE Time&Date: 12:58:59 09/15/2004
USER NAME:

User_NSN

COMMAND:

Shutdown BTSM:NAME=BTSM:0;

SW RELEASE:

01-04-17-01-26-51_05-02-23

COMMAND RESULT: Operation successful

A50016-G5100-B333-04-7619

Id:0900d805805944aa

177

BTSM

BS-4x / 82 II / 240 / 241 / 240XL commands

END OF OUTPUT FOR JOB 59

CHANGED STATE EVENT REPORT:


This provides information about the administrative state, the operational state and the
availability status every time a state change occurs.
Operation Failed
The specified change of administrative state has not been performed.
Application Guidelines:
None.
Example of Command Execution:
Shutdown BTSM:NAME=REMINV:0;

UNLOCKREQUEST BTSM
UNLOCKREQUEST
BTSM

NAME=BTSM:0..0;

Command Tree:
MANAGED-ELEMENT h BSS-FUNCTIONAL h BTSM h UNLOCKREQUEST
BTSM
Applicability:
Phase 3.
Visibility level: 1.
Command Description:
This command sends a request to the BSC for the unlocking of the BTSM. The BTSM
will be able to handle telecom traffic.
Long Names:
NAME

Address of the managed object

System Responses:
Operation Completed
The specified change of administrative state has been perfomed.
JOB: 57
PC Time&Date: 11:57:14 03/23/2005
NE Time&Date: 12:58:49 09/15/2004
USER NAME:

178

User_NSN

Id:0900d805805944aa

A50016-G5100-B333-04-7619

BS-4x / 82 II / 240 / 241 / 240XL commands

COMMAND:
SW RELEASE:

BTSM

Unlockrequest BTSM:NAME=BTSM:0;
01-04-17-01-26-51_05-02-23

COMMAND RESULT: Operation successful


END OF OUTPUT FOR JOB 57

CHANGED STATE EVENT REPORT:


This provides information about the administrative state, the operational state and the
availability status every time a state change occurs.
Operation Failed
The specified change of administrative state has not been performed.
Application Guidelines:

Unlocking of BTSM causes a full BTS-Alignment

In case of issuing BTSE configuration commands during an alignment, a new alignment will be started

Example of Command Execution:


Unlockrequest BTSM:NAME=BTSM:0;

A50016-G5100-B333-04-7619

Id:0900d805805944aa

179

CESPW

BS-4x / 82 II / 240 / 241 / 240XL commands

CESPW
The new HMO CESPW represents one UDP stream which is both received and simultaneously transmitted to the peer.
The object is introduced for the following purposes:

setting of the UPD port numbers

configuration of the mapping between CESoPSN payload and internal TDM


highways

adjustment of packetization latency (transmission) and jitter buffer (reception)

CREATE CESPW
CREATE CESPW

NAME=CESPW:0..7 [,PWNAME=] ,LOCLUDP= ,PEERUDPPORT= ,TDMAP= [,PKTLAT=] [,MAXPDV=];

Command Tree:
MANAGED-ELEMENT h BSS-EQUIPMENT h BTSEP h CESPW h CREATE
CESPW
Applicability:
Phase 2 and Phase 3.
Visibility level: 2.
Command Description:
This command adds the CESPW to the BTSE data base.
Long Names:
NAME

Address of the managed object

PWNAME

pwName

LOCLUDP

localUdpPort

PEERUDPPORT

peerUdpPort

TDMAP

tdmMapping

PKTLAT

packetizationLatency

MAXPDV

maxPdv(ms)

System Responses:
Operation Completed
After command execution, a message of Changed Configuration Notification is displayed.
A further message indicates the result of the operation. An example of create command
is the following:
JOB: 60
PC Time&Date: 02.04.2008 09:10:46 +02:00

180

Id:0900d805805944ac

A50016-G5100-B333-04-7619

BS-4x / 82 II / 240 / 241 / 240XL commands

CESPW

NE Time&Date: 01.01.1990 18:26:24 +00:00


USER NAME:

User_Robert

COMMAND:
Create CESPW:NAME=CESPW:0,LOCLUDP=49200,PEERUDP=49200,TDMAP=1-2-3-4-0-0-0-0-0-0-0-0-0-0-0-0-0-0-0-0-0-0-0-0-0-0-0-0-0-0-0;
SW RELEASE:

01-04-19-01-08-CR_08-03-31

COMMAND RESULT: Operation successful

localUdpPort = 49200
peerUdpPort = 49200
tdmMapping =
pTs1 = 1
pTs2 = 2
pTs3 = 3
pTs4 = 4
pTs5 = 0
pTs6 = 0
pTs7 = 0
pTs8 = 0
pTs9 = 0
pTs10 = 0
pTs11 = 0
pTs12 = 0
pTs13 = 0
pTs14 = 0
pTs15 = 0
pTs16 = 0
pTs17 = 0
pTs18 = 0
pTs19 = 0
pTs20 = 0
pTs21 = 0
pTs22 = 0
pTs23 = 0
pTs24 = 0
pTs25 = 0
pTs26 = 0
pTs27 = 0

A50016-G5100-B333-04-7619

Id:0900d805805944ac

181

CESPW

BS-4x / 82 II / 240 / 241 / 240XL commands

pTs28 = 0
pTs29 = 0
pTs30 = 0
pTs31 = 0

END OF OUTPUT FOR JOB 60


Operation Failed
None.
Application Guidelines:
The creation of a CESPW instance is rejected if no CESTUNNEL has been created
before.
Example of Command Execution:
Create CESPW:NAME=CESPW:0,LOCLUDP=49200,MAXPDV=16,PEERUDPPORT=49200,PKTLAT=m1000,PWNAME="trial1",TDMAP=0-0-0-0-0-0-0-0-0-0-0-0-00-0-0-0-0-0-0-0-0-0-0-0-0-0-0-0-0-0;

DELETE CESPW
DELETE CESPW

NAME=CESPW:0..7;

Command Tree:
MANAGED-ELEMENT h BSS-EQUIPMENT h BTSEP h CESPW h DELETE
CESPW
Applicability:
Phase 2 and Phase 3.
Visibility level: 2.
Command Description:
This command deletes the CESPW from the BTSE data base.
Long Names:
NAME

Address of the managed object

System Responses:
Operation Completed
After command execution, a message of Changed Configuration Notification is displayed.
A further message indicates the result of the operation. An example of delete command
is the following:
JOB: 503

182

Id:0900d805805944ac

A50016-G5100-B333-04-7619

BS-4x / 82 II / 240 / 241 / 240XL commands

CESPW

PC Time&Date: 05.06.2008 13:45:42 +02:00


NE Time&Date: 01.01.1990 00:42:25 +00:00
USER NAME:

User_Robert

COMMAND:

Delete CESPW:NAME=CESPW:7;

SW RELEASE:

01-04-19-01-09-ZS_08-06-05

COMMAND RESULT: Operation successful

END OF OUTPUT FOR JOB 503


Operation Failed
None.
Application Guidelines:
None.
Example of Command Execution:
Delete CESPW:NAME=CESPW:0;

GET CESPW
GET CESPW

NAME=CESPW:0..7 [,REQATTL=ALS, AST, AVS, OST,


PRS, RELFUNCOBJ, PWNAME, LOCLUDP, PEERUDPPORT, TDMAP, PKTLAT, MAXPDV];

Command Tree:
MANAGED-ELEMENT h BSS-EQUIPMENT h BTSEP h CESPW h GET
CESPW
Applicability:
Phase 2 and Phase 3.
Visibility level: 0.
Command Description:
This command displays the attributes of the CESPW.
Long Names:
NAME

Address of the managed object

REQATTL

Required attribute list

ALS

alarmStatus

AST

administrativeState

AVS

availabilityStatus

OST

operationalState

PRS

proceduralStatus

RELFUNCOBJ

A50016-G5100-B333-04-7619

relatedFuncObjects

Id:0900d805805944ac

183

CESPW

BS-4x / 82 II / 240 / 241 / 240XL commands

PWNAME

pwName

LOCLUDP

localUdpPort

PEERUDPPORT

peerUdpPort

TDMAP

tdmMapping

PKTLAT

packetizationLatency

MAXPDV

maxPdv(ms)

System Responses:
Operation Completed
A message indicates the result of the operation. An example of get command is the following:
JOB: 9
PC Time&Date: 02.10.2008 09:06:43 +02:00
NE Time&Date: 02.10.2008 06:50:36 +01:00
USER NAME:

User_Robert

COMMAND:

Get CESPW:NAME=CESPW:0;

SW RELEASE:

01-04-19-01-12-ZT_08-09-29

COMMAND RESULT: Operation successful

alarmStatus = CLEARED
administrativeState = Unlocked
availabilityStatus = NULL
operationalState = ENABLED
proceduralStatus = NULL
relatedFuncObjects = Null
pwName = "Null"
localUdpPort = 49300
peerUdpPort = 49300
tdmMapping =
pTs1 = 1
pTs2 = 2
pTs3 = 3
pTs4 = 4
pTs5 = 5
pTs6 = 0
pTs7 = 0

184

Id:0900d805805944ac

A50016-G5100-B333-04-7619

BS-4x / 82 II / 240 / 241 / 240XL commands

CESPW

pTs8 = 0
pTs9 = 0
pTs10 = 0
pTs11 = 0
pTs12 = 0
pTs13 = 0
pTs14 = 0
pTs15 = 0
pTs16 = 0
pTs17 = 0
pTs18 = 0
pTs19 = 0
pTs20 = 0
pTs21 = 0
pTs22 = 0
pTs23 = 0
pTs24 = 0
pTs25 = 0
pTs26 = 0
pTs27 = 0
pTs28 = 0
pTs29 = 0
pTs30 = 0
pTs31 = 0
packetizationLatency = m1000
maxPdv(ms) = 2.000
END OF OUTPUT FOR JOB 9
Operation Failed
None.
Application Guidelines:
None.
Example of Command Execution:
Get CESPW:NAME=CESPW:0;REQATTL=ALS&AST&AVS&OST&PRS&RELFUNCOBJ&LOCLUDP&MAXPDV&PEERUDPPORT&PKTLAT&PWNAME&TDMAP;

LOCK CESPW
LOCK CESPW

A50016-G5100-B333-04-7619

NAME=CESPW:0..7;

Id:0900d805805944ac

185

CESPW

BS-4x / 82 II / 240 / 241 / 240XL commands

Command Tree:
MANAGED-ELEMENT h BSS-EQUIPMENT h BTSEP h CESPW h LOCK
CESPW
Applicability:
Phase 2 and Phase 3.
Visibility level: 1.
Command Description:
This command changes the administrative state of CESPW.
Long Names:
NAME

Address of the managed object

System Responses:
Operation Completed
The specified change of administrative state has been perfomed:
JOB: 29
PC Time&Date: 05.06.2008 13:06:00 +02:00
NE Time&Date: 01.01.1990 00:02:44 +00:00
USER NAME:

User_Robert

COMMAND:

Lock CESPW:NAME=CESPW:0;

SW RELEASE:

01-04-19-01-09-ZS_08-06-03

COMMAND RESULT: Operation successful

administrativeState = Locked
END OF OUTPUT FOR JOB 29
Operation Failed
None.
Application Guidelines:
None.
Example of Command Execution:
Lock CESPW:NAME=CESPW:0;

186

Id:0900d805805944ac

A50016-G5100-B333-04-7619

BS-4x / 82 II / 240 / 241 / 240XL commands

CESPW

SET CESPW
SET CESPW

NAME=CESPW:0..7 [,PWNAME=] [,LOCLUDP=] [,PEERUDPPORT=] [,TDMAP=] [,PKTLAT=] [,MAXPDV=];

Command Tree:
MANAGED-ELEMENT h BSS-EQUIPMENT h BTSEP h CESPW h SET
CESPW
Applicability:
Phase 2 and Phase 3.
Visibility level: 2.
Command Description:
This command sets the attributes of CESPW to the BTSE data base.
Long Names:
NAME

Address of the managed object

PWNAME

pwName

LOCLUDP

localUdpPort

PEERUDPPORT

peerUdpPort

TDMAP

tdmMapping

PKTLAT

packetizationLatency

MAXPDV

maxPdv(ms)

System Responses:
Operation Completed
After command execution, a message of Changed Configuration Notification is displayed.
A further message indicates the result of the operation. An example of set command is
the following:
JOB: 32
PC Time&Date: 05.06.2008 13:06:09 +02:00
NE Time&Date: 01.01.1990 00:02:53 +00:00
USER NAME:

User_Robert

COMMAND:

Set CESPW:NAME=CESPW:0,MAXPDV=0.125;

SW RELEASE:

01-04-19-01-09-ZS_08-06-03

COMMAND RESULT: Operation successful

maxPdv = 0.125

A50016-G5100-B333-04-7619

Id:0900d805805944ac

187

CESPW

BS-4x / 82 II / 240 / 241 / 240XL commands

END OF OUTPUT FOR JOB 32


Operation Failed
None.
Application Guidelines:
Any modification of the mapping is allowed only if the CESPW has been previously
locked.
Example of Command Execution:
Set CESPW:NAME=CESPW:0,LOCLUDP=49200,PEERUDP=49200,TDMAP=1-2-34-0-0-0-0-0-0-0-0-0-0-0-0-0-0-0-0-0-0-0-0-0-0-0-0-0-0-0;

UNLOCK CESPW
UNLOCK CESPW

NAME=CESPW:0..7;

Command Tree:
MANAGED-ELEMENT h BSS-EQUIPMENT h BTSEP h CESPW h UNLOCK
CESPW
Applicability:
Phase 2 and Phase 3.
Visibility level: 1.
Command Description:
This command changes the administrative state of CESPW.
Long Names:
NAME

Address of the managed object

System Responses:
Operation Completed
The specified change of administrative state has been perfomed:
JOB: 84
PC Time&Date: 05.06.2008 13:17:19 +02:00
NE Time&Date: 01.01.1990 00:14:03 +00:00
USER NAME:

User_Robert

COMMAND:

Unlock CESPW:NAME=CESPW:0;

SW RELEASE:

01-04-19-01-09-ZS_08-06-03

COMMAND RESULT: Operation successful

188

Id:0900d805805944ac

A50016-G5100-B333-04-7619

BS-4x / 82 II / 240 / 241 / 240XL commands

CESPW

administrativeState = Unlocked
END OF OUTPUT FOR JOB 84
Operation Failed
None.
Application Guidelines:
None.
Example of Command Execution:
Unlock CESPW:NAME=CESPW:0;

A50016-G5100-B333-04-7619

Id:0900d805805944ac

189

CESTUNNEL

BS-4x / 82 II / 240 / 241 / 240XL commands

CESTUNNEL
This object represents the PSN tunnel. As the BTSE is uniquely connected to one BSC
there is only one CESTUNNEL instance per BTSE. The CESTUNNEL object is introduced for the following purposes:

setting of the local (BTSE) and peer IP address

setting of attributes which apply for all pseudo wires

CREATE CESTUNNEL
CREATE CESTUNNEL NAME=CESTUNNEL:0..0 ,LOCALADDR= ,PEERADDR=
[,VLANID=] [,LOSPKTTH=] [,ALRMPERT=] [,ALRMCLET=]
[,NTWTYPC=] [,PNGF=] [,PNGPKT=];
Command Tree:
MANAGED-ELEMENT h BSS-EQUIPMENT h BTSEP h CESTUNNEL h
CREATE CESTUNNEL
Applicability:
Phase 2.
Visibility level: 2.
Command Description:
This command adds the CESTUNNEL to the BTSE data base.

Long Names:
NAME

Address of the managed object

LOCALADDR

localAddress

PEERADDR

peerAddress

VLANID

vlanId

LOSPKTTH

lostPacketThreshold

ALRMPERT

alarmPersistencyTime

ALRMCLET

alarmClearanceTime

NTWTYPC

networkTypeCompensation

PNGF

pingFrequency

PNGPKT

pingPacketSize

System Responses:
Operation Completed
After command execution, a message of Changed Configuration Notification is displayed.
A further message indicates the result of the operation. An example of create command
is the following:

190

Id:0900d805805944ae

A50016-G5100-B333-04-7619

BS-4x / 82 II / 240 / 241 / 240XL commands

CESTUNNEL

JOB: 59
PC Time&Date: 18.04.2008 10:07:46 +02:00
NE Time&Date: 01.01.1990 00:17:52 +00:00
USER NAME:

User_Paul

COMMAND:
Create CESTUNNEL:NAME=CESTUNNEL:0,LOCLADR="192.168.3.23", PEERADR="192.168.3.24";
SW RELEASE:

01-04-19-01-07-01_08-04-03

COMMAND RESULT: Operation successful

localAddress = "192.168.3.23"
peerAddress = "192.168.3.24"

END OF OUTPUT FOR JOB 59


Operation Failed
None.
Application Guidelines:
The creation of the CESTUNNEL is rejected if no ETHCON object exists.
Example of Command Execution:
Create CESTUNNEL:NAME=CESTUNNEL:0,ALRMCLET=10,ALRMPERT=3,LOCALADDR="192.168.3.23",LOSPKTTH=1,NTWTYPC=255,NTWTYPC=0,PEERADDR="192.168.3.25",PNGF=0,PNGPKT=TRAFFIC,VLANID=<NULL
>

DELETE CESTUNNEL
DELETE CESTUNNEL

NAME=CESTUNNEL:0..0;

Command Tree:
MANAGED-ELEMENT h BSS-EQUIPMENT h BTSEP h CESTUNNEL h
DELETE CESTUNNEL
Applicability:
Phase 2.
Visibility level: 2.
Command Description:
This command deletes the CESTUNNEL from the BTSE data base.

A50016-G5100-B333-04-7619

Id:0900d805805944ae

191

CESTUNNEL

BS-4x / 82 II / 240 / 241 / 240XL commands

Long Names:
NAME

Address of the managed object

System Responses:
Operation Completed
None.
Operation Failed
None.
Application Guidelines:
CESTUNNEL deletion is rejected if a CESPW object exists.
Example of Command Execution:
Delete CESTUNNEL:NAME=CESTUNNEL:0;

GET CESTUNNEL
GET CESTUNNEL

NAME=CESTUNNEL:0..0 [,REQATTL=ALS, AST, AVS,


OST, PRS, RELFUNCOBJ, LOCALADDR, PEERADDR,
VLANID, LOSPKTTH, ALRMPERT, ALRMCLET,
NTWTYPC, PNGF, PNGPKT];

Command Tree:
MANAGED-ELEMENT h BSS-EQUIPMENT h BTSEP h CESTUNNEL h GET
CESTUNNEL
Applicability:
Phase 2 and Phase 3.
Visibility level: 0.
Command Description:
This command displays the attributes of the CESTUNNEL.
Long Names:
NAME

Address of the managed object

REQATTL

Required attribute list

ALS

alarmStatus

AST

administrativeState

AVS

availabilityStatus

OST

operationalState

PRS

proceduralStatus

RELFUNCOBJ

192

relatedFuncObjects

LOCALADDR

localAddress

PEERADDR

peerAddress

VLANID

vlanId

LOSPKTTH

lostPacketThreshold

Id:0900d805805944ae

A50016-G5100-B333-04-7619

BS-4x / 82 II / 240 / 241 / 240XL commands

CESTUNNEL

ALRMPERT

alarmPersistencyTime

ALRMCLET

alarmClearanceTime

NTWTYPC

networkTypeCompensation

PNGF

pingFrequency

PNGPKT

pingPacketSize

System Responses:
Operation Completed
A message indicates the result of the operation. An example of get command is the following:
JOB: 75
PC Time&Date: 21.08.2008 13:48:47 +02:00
NE Time&Date: 21.08.2008 13:38:17 +01:00
USER NAME:

User_Paul

COMMAND:

Get CESTUNNEL:NAME=CESTUNNEL:0;

SW RELEASE:

01-04-19-01-12-ZT_08-08-20

COMMAND RESULT: Operation successful

alarmStatus = CLEARED
administrativeState = Locked
availabilityStatus = NULL
operationalState = ENABLED
proceduralStatus = NULL
relatedFuncObjects = Null
localAddress = "192.168.3.23"
peerAddress = "192.168.3.25"
vlanId = Null
lostPacketThreshold = 1
alarmPersistencyTime = 3
alarmClearanceTime = 10
networkTypeCompensation = 0
pingFrequency = 0
pingPacketSize = TRAFFIC
END OF OUTPUT FOR JOB 75
Operation Failed

A50016-G5100-B333-04-7619

Id:0900d805805944ae

193

CESTUNNEL

BS-4x / 82 II / 240 / 241 / 240XL commands

None.
Application Guidelines:
None.
Example of Command Execution:
Get
CESTUNNEL:NAME=CESTUNNEL:0,REQATTL=ALS&AST&AVS&OST&PRS&RELFUNCOBJ&ALRMCLET&ALRMPERT&LOCALADDR&LOSPKTTH&NTWTYPC&PEERADDR&PNGF&PNGPKT&VLANID;

LOCK CESTUNNEL
LOCK CESTUNNEL

NAME=CESTUNNEL:0..0;

Command Tree:
MANAGED-ELEMENT h BSS-EQUIPMENT h BTSEP h CESTUNNEL h LOCK
CESTUNNEL
Applicability:
Phase 2.
Visibility level: 1.
Command Description:
This command changes the administrative state of CESTUNNEL.
Long Names:
NAME

Address of the managed object

System Responses:
Operation Completed
The specified change of administrative state has been perfomed:
JOB: 39
PC Time&Date: 05.05.2008 09:07:05 +02:00
NE Time&Date: 05.05.2008 09:03:21 +01:00
USER NAME:

User_Paul

COMMAND:

Lock CESTUNNEL:NAME=CESTUNNEL:0;

SW RELEASE:

01-04-19-01-07-ZT_08-04-30

COMMAND RESULT: Operation successful

administrativeState = Locked

194

Id:0900d805805944ae

A50016-G5100-B333-04-7619

BS-4x / 82 II / 240 / 241 / 240XL commands

CESTUNNEL

END OF OUTPUT FOR JOB 39


Operation Failed
None.
Application Guidelines:
None.
Example of Command Execution:
Lock CESTUNNEL:NAME=CESTUNNEL:0;

SET CESTUNNEL
SET CESTUNNEL

NAME=CESTUNNEL:0..0 [,LOCALADDR=] [,PEERADDR=]


[,VLANID=] [,LOSPKTTH=] [,ALRMPERT=] [,ALRMCLET=]
[,NTWTYPC=] [,PNGF=] [,PNGPKT=];

Command Tree:
MANAGED-ELEMENT h BSS-EQUIPMENT h BTSEP h CESTUNNEL h SET
CESTUNNEL
Applicability:
Phase 2 and Phase 3.
Visibility level: 2.
Command Description:
This command sets the attributes of CESTUNNEL.
Long Names:
NAME

Address of the managed object

LOCALADDR

localAddress

PEERADDR

peerAddress

VLANID

vlanId

LOSPKTTH

lostPacketThreshold

ALRMPERT

alarmPersistencyTime

ALRMCLET

alarmClearanceTime

NTWTYPC

networkTypeCompensation

PNGF

pingFrequency

PNGPKT

pingPacketSize

System Responses:
Operation Completed
After command execution, a message of Changed Configuration Notification is displayed.
A further message indicates the result of the operation. An example of set command is
the following:

A50016-G5100-B333-04-7619

Id:0900d805805944ae

195

CESTUNNEL

BS-4x / 82 II / 240 / 241 / 240XL commands

JOB: 77
PC Time&Date: 21.08.2008 13:49:06 +02:00
NE Time&Date: 21.08.2008 13:38:36 +01:00
USER NAME:

User_Paul

COMMAND:

Set CESTUNNEL:NAME=CESTUNNEL:0,VLANID=<NULL>;

SW RELEASE:

01-04-19-01-12-ZT_08-08-20

COMMAND RESULT: Operation successful

vlanId = Null

END OF OUTPUT FOR JOB 77


Operation Failed
None.
Application Guidelines:
None.
Example of Command Execution:
Set CESTUNNEL:NAME=RACK:0/CESTUNNEL:0,ALRMCLET=10,ALRMPERT=3,LOCALADDR="123.20.254.36",LOSPKTTH=1,NTWTYPC=255,NTWTYPC=255,PEERADDR="156.14.26.2",PNGF=0,PNGPKT=TRAFFIC,VLANID=0

UNLOCK CESTUNNEL
UNLOCK CESTUNNEL NAME=CESTUNNEL:0..0;
Command Tree:
MANAGED-ELEMENT h BSS-EQUIPMENT h BTSEP h CESTUNNEL h
UNLOCK CESTUNNEL
Applicability:
Phase 2.
Visibility level: 1.
Command Description:
This command changes the administrative state of CESTUNNEL.

Long Names:
NAME

196

Address of the managed object

Id:0900d805805944ae

A50016-G5100-B333-04-7619

BS-4x / 82 II / 240 / 241 / 240XL commands

CESTUNNEL

System Responses:
Operation Completed
The specified change of administrative state has been perfomed:
JOB: 47
PC Time&Date: 05.05.2008 09:08:17 +02:00
NE Time&Date: 05.05.2008 09:04:33 +01:00
USER NAME:

User_Paul

COMMAND:

Unlock CESTUNNEL:NAME=CESTUNNEL:0;

SW RELEASE:

01-04-19-01-07-ZT_08-04-30

COMMAND RESULT: Operation successful

administrativeState = Unlocked
END OF OUTPUT FOR JOB 47
Operation Failed
None.
Application Guidelines:
None.
Example of Command Execution:
Unlock CESTUNNEL:NAME=CESTUNNEL:0

A50016-G5100-B333-04-7619

Id:0900d805805944ae

197

CHAN

BS-4x / 82 II / 240 / 241 / 240XL commands

CHAN
The CHAN object represents the radio time slot in which the radio carrier is subdivided
into time sharing; it can be differently configured depending on its usage for the telephone application software (full rate or half rate traffic channels, dedicated or common
control channels).

GET CHAN
GET CHAN

NAME=BTS:0..11/TRX:0..23/CHAN:0..7 [,REQATTL=AST,
AVS, CHTYPE, EXTMODE, HSN, MAIO, MOBALLOC, OST,
RELEQUIPOBJ, TSC];

Command Tree:
MANAGED-ELEMENT h BSS-FUNCTIONAL h BTSM h BTS h TRX h CHAN
h GET CHAN
Applicability:
Phase 3.
Visibility level: 0.
Command Description:
This command displays the physical radio channel with its specific attributes which
allows logical channels to be mapped onto physical radio channels.
Long Names:
NAME

Address of the managed object

REQATTL

Required attribute list

AST

administrativeState

AVS

availabilityStatus

CHTYPE

channelCombination

EXTMODE

extendedMode

HSN

hoppingSequenceNumber

MAIO

maio

MOBALLOC

arfcnList

OST

operationalState

RELEQUIPOBJ
TSC

relatedEquipObjects
trainingSequenceCode

System Responses:
Operation Completed
A message indicates the result of the operation. An example of get command is the following:
JOB: 17

198

Id:0900d805805944b0

A50016-G5100-B333-04-7619

BS-4x / 82 II / 240 / 241 / 240XL commands

CHAN

PC Time&Date: 11:33:17 03/23/2005


NE Time&Date: 11:31:08 09/15/2004
USER NAME:

User_n

COMMAND:

Get CHAN:NAME=BTS:0/TRX:0/CHAN:0;

SW RELEASE:

01-04-17-01-26-51_05-02-23

COMMAND RESULT: Operation successful


administrativeState = Unlocked
availabilityStatus = NULL
channelCombination = MAINBCCH
extendedMode = FALSE
hoppingSequenceNumber = 0
maio = 0
arfcnList =
operationalState = ENABLED
relatedEquipObjects =
trainingSequenceCode = TSC_is_BCC_of_BSIC
END OF OUTPUT FOR JOB 17
Operation Failed
The GET command has not been successfully executed. A general NACK will indicate
possible errors or a specific NACK strictly related to the single command is possible.
Application Guidelines:
None.
Example of Command Execution:
Get CHAN:NAME=BTS:0/TRX:0/CHAN:0,REQATTL=AST&AVS&CHTYPE&
EXTMODE&HSN&MAIO&MOBALLOC&OST&RELEQUIPOBJ&TSC;

A50016-G5100-B333-04-7619

Id:0900d805805944b0

199

COBA

BS-4x / 82 II / 240 / 241 / 240XL commands

COBA
The COBA module controls of the entire BTSE, generates the system clocks, provides
for up to 2 Abis-interfaces to BSC or other BTSEs, routes the Abis-data to up to 8 Carrier
Agents, provides for an interface to the LMT/OTP, handles and processes the O&Mmessages.

CREATE COBA
CREATE COBA

NAME=RACK:0..7/COBA:0..1 [,ALRMCOUNTER=]
[,ALRMT1/2/3=] [,EFCUSUP=];

Command Tree:
MANAGED-ELEMENT h BSS-EQUIPMENT h BTSEP h RACK h COBA h
CREATE COBA
Applicability:
Phase 2 and Phase 3.
Visibility level: 2.
Command Description:
This command adds the COBA (Core Basis module) to the BTSE data base.
Long Names:
NAME

Address of the managed object

ALRMCOUNTER

alarmCount

ALRMT1/2/3

alarmTiming1(sec)/alarmTiming2(sec)/alarmTiming3(5 minutes units)

EFCUSUP

enableFcuSupport

System Responses:
Operation Completed
After command execution, a message of Changed Configuration Notification is displayed.
A further message indicates the result of the operation. An example of create command
is the following:
JOB: 158
PC Time&Date: 16:45:36 03/23/2005
NE Time&Date: 16:43:30 09/15/2004
USER NAME:

User_Cindy

SW RELEASE:

01-04-17-01-26-51_05-02-23

COMMAND RESULT: Operation successful

200

Id:0900d80580627a91

A50016-G5100-B333-04-7619

BS-4x / 82 II / 240 / 241 / 240XL commands

COBA

ChangedConfigurationNotification:
name = RACK:0/COBA:1
ChangeInfo = created
END OF OUTPUT FOR JOB 158
JOB: 159
PC Time&Date: 16:45:36 03/23/2005
NE Time&Date: 16:43:30 09/15/2004
USER NAME:

User_Cindy

COMMAND:

Create COBA:NAME=RACK:0/COBA:1;

SW RELEASE:

01-04-17-01-26-51_05-02-23

COMMAND RESULT: Operation successful


END OF OUTPUT FOR JOB 159
Operation Failed
The specified Object has not been created. In addition to the general NACK causes, a
specific NACK cause, which indicates that the command is inconsistent with the
physical configuration, is possible. An example is the following:
JOB: 71
PC Time&Date: 16:37:54 03/23/2005
NE Time&Date: 16:35:47 09/15/2004
USER NAME:

User_Cindy

COMMAND:

Create COBA:NAME=RACK:0/COBA:1;

SW RELEASE:

01-04-17-01-26-51_05-02-23

COMMAND RESULT: OPERATION FAILED


Object instance unknown (-9)
END OF OUTPUT FOR JOB 71
Application Guidelines:

Only COBA:1 can be created.

A50016-G5100-B333-04-7619

Id:0900d80580627a91

201

COBA

BS-4x / 82 II / 240 / 241 / 240XL commands

Example of Command Execution:


Create COBA:NAME=RACK:0/COBA:1,ALRMCOUNTER=234,ALRMT1=23,
ALRMT2=34,ALRMT3=2, EFCUSUP=TRUE;

DELETE COBA
DELETE COBA

NAME=RACK:0..7/COBA:0..1;

Command Tree:
MANAGED-ELEMENT h BSS-EQUIPMENT h BTSEP h RACK h COBA h
DELETE COBA
Applicability:
Phase 2 and Phase 3.
Visibility level: 2.
Command Description:
This command deletes the attributes of the COBA (Core Basis module).
Long Names:
NAME

Address of the managed object

System Responses:
Operation Completed
After command execution, a message of Changed Configuration Notification is displayed. A further message indicates the result of the operation. An example of delete
command is the following:
JOB: 182
PC Time&Date: 16:48:02 03/23/2005
NE Time&Date: 16:45:56 09/15/2004
USER NAME:

User_Cindy

SW RELEASE:

01-04-17-01-26-51_05-02-23

COMMAND RESULT: Operation successful


ChangedConfigurationNotification:
name = RACK:0/COBA:1
ChangeInfo = deleted
END OF OUTPUT FOR JOB 182

202

Id:0900d80580627a91

A50016-G5100-B333-04-7619

BS-4x / 82 II / 240 / 241 / 240XL commands

COBA

JOB: 183
PC Time&Date: 16:48:02 03/23/2005
NE Time&Date: 16:45:56 09/15/2004
USER NAME:

User_Cindy

COMMAND:

Delete COBA:NAME=RACK:0/COBA:1;

SW RELEASE:

01-04-17-01-26-51_05-02-23

COMMAND RESULT: Operation successful


END OF OUTPUT FOR JOB 183
Operation Failed
The specified Object has not been deleted. Additionally to the general NACK causes, a
specific NACK cause, meaning that the command is inconsistent with physical configuration, is possible.
Application Guidelines:

Only COBA:1 can be deleted

COBA:1 must be locked in Phase 3 before deletion

Example of Command Execution:


Delete COBA:NAME=RACK:0/COBA:1;

GET COBA
GET COBA

NAME=RACK:0..7/COBA:0..1 [,REQATTL=ALRMCOUNTER, ALRMT1/2/3, ALS, AST, AVS, BCPBL, BSWVER,


EFCUSUP, OST, PRS, RELFUNCOBJ, SLOTNO, STDBYST];

Command Tree:
MANAGED-ELEMENT h BSS-EQUIPMENT h BTSEP h RACK h COBA h
GET COBA
Applicability:
Phase 2 and Phase 3.
Visibility level: 0.
Command Description:
This command displays the attributes of the COBA (Core Basis module).
Long Names:
NAME

Address of the managed object

REQATTL

Required attribute list

ALRMCOUNTER

A50016-G5100-B333-04-7619

alarmCount

Id:0900d80580627a91

203

COBA

BS-4x / 82 II / 240 / 241 / 240XL commands

ALRMT1/2/3

alarmTiming1(sec)/alarmTiming2(sec)/alarmTiming3(5 minutes units)

ALS

alarmStatus

AST

administrativeState

AVS

availabilityStatus

BCPBL

boardCapability

BSWVER

bootSoftwareVersion

EFCUSUP

enableFcuSupport

OST

operationalState

PRS

proceduralStatus

RELFUNCOBJ

relatedFuncObjects

SLOTNO

slotNo

STDBYST

standbyStatus

System Responses:
Operation Completed
A message indicates the result of the operation. An example of get command is the following:
JOB: 163
USER NAME:

User_Cindy

COMMAND:

Get COBA:NAME=RACK:0/COBA:0;

SW RELEASE:

01-04-17-01-26-51_05-02-23

COMMAND RESULT: Operation successful


acPeriod = 20
alarmCount = 32
alarmTiming1(sec) = 20
alarmTiming2(sec) = 1
alarmTiming3(*5min) = 1 (unit of 5 minutes)
alarmStatus = CLEARED
administrativeState = Unlocked
availabilityStatus = NULL
boardCapability = twoAbisLines
bootSoftwareVersion = "BTBBCX01.SWI:01-01-11-00-18-00_04-06-13"
enableFcuSupport = FALSE
operationalState = ENABLED
proceduralStatus = NULL
slotNo = leftCOBA
standbyStatus = ProvidingService

204

Id:0900d80580627a91

A50016-G5100-B333-04-7619

BS-4x / 82 II / 240 / 241 / 240XL commands

COBA

END OF OUTPUT FOR JOB 163


Operation Failed
The GET command has not been successfully executed. A general NACK will indicate
possible errors or a specific NACK strictly related to the single command is possible.
Application Guidelines:

COBA:0 is the one with Providing Service Status, COBA:1 is in Standby Status

Example of Command Execution:


Get COBA:NAME=RACK:0/COBA:0,REQATTL=ACPER&ALRMCOUNTER&ALRMT1&ALRMT2&ALRMT3&ALS&AST&AVS&BCPBL&BSWVER&CCLKACC
&EFCUSUP&OST&PRS&SLOTNO&STDBYST;

GETRELATIONSHIP COBA
GETRELATIONSHIP
COBA

NAME=RACK:0..7/COBA:0..1;

Command Tree:
MANAGED-ELEMENT h BSS-EQUIPMENT h BTSEP h RACK h COBA h
GETRELATIONSHIP COBA
Applicability:
Phase 2 and Phase 3.
Visibility level: 0.
Command Description:
This command adds the COBA (Core Basis module) to the BTSE data base.
Long Names:
NAME

Address of the managed object

REQATTL

Required attribute list

System Responses:
Operation Completed
A message indicates the result of the operation. An example of getrelationship
command is the following:
JOB: 164

PC Time&Date: 15:08:34 03/23/2005


NE Time&Date: 16:11:29 09/15/2004
USER NAME:

A50016-G5100-B333-04-7619

User_Cindy

Id:0900d80580627a91

205

COBA

BS-4x / 82 II / 240 / 241 / 240XL commands

COMMAND:

Getrelationship COBA:NAME=RACK:0/COBA:0;

SW RELEASE:

01-04-17-01-26-51_05-02-23

COMMAND RESULT: Operation successful

END OF OUTPUT FOR JOB 164


Operation Failed
The GET command has not been successfully executed. A general NACK will indicate
possible errors or a specific NACK strictly related to the single command is possible.
Application Guidelines:
None.
Example of Command Execution:
Getrelationship COBA:NAME=RACK:0/COBA:0;

GETTEST COBA
GETTEST COBA

NAME=RACK:0..7/COBA:0..1;

Command Tree:
MANAGED-ELEMENT h BSS-EQUIPMENT h BTSEP h RACK h COBA h
GETTEST COBA
Applicability:
Phase 2 and Phase 3.
Visibility level: 0.
Command Description:
This command displays the attributes of the COBA test.
Long Names:
NAME

Address of the managed object

REQATTL

Required attribute list

System Responses:
Operation Completed
A message indicates the result of the operation. An example of gettest command is the
following:
JOB: 187
PC Time&Date: 12:07:21 03/23/2005
NE Time&Date: 13:08:54 09/15/2004
USER NAME:

206

User_Cindy

Id:0900d80580627a91

A50016-G5100-B333-04-7619

BS-4x / 82 II / 240 / 241 / 240XL commands

COMMAND:
SW RELEASE:

COBA

Gettest COBA:NAME=RACK:0/COBA:0;
01-04-17-01-26-51_05-02-23

COMMAND RESULT: Operation successful


MOT = RACK:0/COBA:0
testMonitor =
phaseId = PreliminaryTestsCoba
phaseStatus = Running
phaseId = CheckAlarmStatusCoba
phaseStatus = Waiting
phaseId = EndTestCoba
phaseStatus = Waiting
testOutcome = INCONCLUSIVE
testState = INITIALIZING
END OF OUTPUT FOR JOB 187
Operation Failed
The GET command has not been successfully executed. A general NACK will indicate
possible errors or a specific NACK strictly related to the single command is possible.
testMonitor
phaseId =
phaseStatus =

it is a list of all test phases related to the


selected object; for each phase the
related phaseStatus is provided (Passed,
Failed, Running or Waiting).

phaseId =
phaseStatus =
...
...
testOutcome

It represents the test result: it can be


Inconclusive (if the phases already
executed were successful) or Fail (if at
least one of the executed phases failed).

testState = Testing

It can assume one of the following values:


not_initialized, idle, initializing, suspended, testing, terminating and disabled.

Application Guidelines:
None.
Example of Command Execution:
Gettest COBA:NAME=RACK:0/COBA:0, REQATTL=MORT&TESTMON&
TESTOUT&TESTST;

A50016-G5100-B333-04-7619

Id:0900d80580627a91

207

COBA

BS-4x / 82 II / 240 / 241 / 240XL commands

LOCK COBA
LOCK COBA

NAME=RACK:0..7/COBA:0..1;

Command Tree:
MANAGED-ELEMENT h BSS-EQUIPMENT h BTSEP h RACK h COBA h
LOCK COBA
Applicability:
Phase 2 and Phase 3.
Visibility level: 1.
Command Description:
This command changes the administrative state of the COBA (Core Basis module).
Long Names:
NAME

Address of the managed object

System Responses:
Operation Completed
The specified change of administrative state has been perfomed:
JOB: 166
PC Time&Date: 16:46:53 03/23/2005
NE Time&Date: 16:44:47 09/15/2004
USER NAME:

User_Cindy

COMMAND:

Lock COBA:NAME=RACK:0/COBA:1;

SW RELEASE:

01-04-17-01-26-51_05-02-23

COMMAND RESULT: Operation successful


administrativeState = Locked
END OF OUTPUT FOR JOB 166

CHANGED STATE EVENT REPORT:


This provides information about the administrative state, the operational state and the
availability status every time a state change occurs:
JOB: 167
PC Time&Date: 16:46:53 03/23/2005
NE Time&Date: 16:44:47 09/15/2004

208

Id:0900d80580627a91

A50016-G5100-B333-04-7619

BS-4x / 82 II / 240 / 241 / 240XL commands

COBA

USER NAME:

User_Cindy

SW RELEASE:

01-04-17-01-26-51_05-02-23

COMMAND RESULT: Operation successful


CHANGED STATE EVENT REPORT:
NAME = RACK:0/COBA:1
Administrative State = LOCKED
Notification Identifier = 551
END OF OUTPUT FOR JOB 167
Operation Failed
The specified change of administrative state has not been performed.
Application Guidelines:

Lock COBA:0 only in Phase 2

Example of Command Execution:


Lock COBA:NAME=RACK:0/COBA:0;

PERFTEST COBA
PERFTEST COBA

NAME=RACK:0..7/COBA:0..1;

Command Tree:
MANAGED-ELEMENT h BSS-EQUIPMENT h BTSEP h RACK h COBA h
PERFTEST COBA
Applicability:
Phase 2 and Phase 3.
Visibility level: 1.
Command Description:
This command is used to start an asynchronous test in COBA.
Long Names:
NAME

Address of the managed object

System Responses:
Operation Completed
Test configuration has been set and the specified test has been started. The System
response will not be addressed to the MOT but to the object BTSEP.
JOB: 188

A50016-G5100-B333-04-7619

Id:0900d80580627a91

209

COBA

BS-4x / 82 II / 240 / 241 / 240XL commands

PC Time&Date: 12:06:51 03/23/2005


NE Time&Date: 13:08:26 09/15/2004
USER NAME:

User_Cindy

COMMAND:

Perftest COBA:NAME=RACK:0/COBA:0;

SW RELEASE:

01-04-17-01-26-51_05-02-23

COMMAND RESULT: Operation successful


MOT = RACK:0/COBA:0
tO = BTSETEST:2
END OF OUTPUT FOR JOB 188
JOB: 189
PC Time&Date: 12:07:23 03/23/2005
NE Time&Date: 13:08:53 09/15/2004
USER NAME:

User_Cindy

SW RELEASE:

01-04-17-01-26-51_05-02-23

COMMAND RESULT: Operation successful


ChangedConfigurationNotification:
name = BTSETEST:2
ChangeInfo = created
END OF OUTPUT FOR JOB 189
JOB: 190
PC Time&Date: 12:07:38 03/23/2005
NE Time&Date: 13:09:02 09/15/2004
USER NAME:

User_Cindy

SW RELEASE:

01-04-17-01-26-51_05-02-23

COMMAND RESULT: Operation successful

210

Id:0900d80580627a91

A50016-G5100-B333-04-7619

BS-4x / 82 II / 240 / 241 / 240XL commands

COBA

CHANGED STATE EVENT REPORT:


NAME = RACK:0/COBA:0
Operational State = ENABLED
Availability Status = NULL_value
Standby Status = Cold_Standby
Notification Identifier = 164
END OF OUTPUT FOR JOB 190
JOB: 191
PC Time&Date: 12:07:52 03/23/2005
NE Time&Date: 13:09:34 09/15/2004
USER NAME:

User_Cindy

SW RELEASE:

01-04-17-01-26-51_05-02-23

COMMAND RESULT: Operation successful


Test Report:
name = BTSETEST:2
testOutcome = PASSED
testTermination = Normal
MOT = RACK:0/COBA:0
executedPhases =
PreliminaryTestsCoba
BootEepromTestCoba
SerialEepromTestCoba
EndTestCoba
END OF OUTPUT FOR JOB 191
JOB: 192
PC Time&Date: 12:08:04 03/23/2005
NE Time&Date: 13:09:28 09/15/2004
USER NAME:

A50016-G5100-B333-04-7619

User_Cindy

Id:0900d80580627a91

211

COBA

BS-4x / 82 II / 240 / 241 / 240XL commands

SW RELEASE:

01-04-17-01-26-51_05-02-23

COMMAND RESULT: Operation successful


ChangedConfigurationNotification:
name = BTSETEST:2
ChangeInfo = deleted
END OF OUTPUT FOR JOB 192
The test results will be displayed at the end of the test phases.
Result TEST:
name =

TEST:<n>

testOutcome =

This field represents the test result; one of the following values can be displayed:
Pass

all the test phases are successfully


performed.

Inconclusive

the test is aborted by the system or


the test is terminated by the operator.

Fail

if at least one of the executed phases


fail.

mOts =

It is the identifier of the hardware object under test.

testTermination =

It specifies how the test is terminated, it can assume


the following values:
Normal

all the test phases are performed.

Abort

the test is aborted by system.

Cancel

the test is terminated by operator.

executedPhases
phaseId =
additionalWords =
....

It represents the list of the executed test phases (in


case of successful test result, all the test phases will
be listed).

failedPhases
phaseId =
phaseId =

It represents the list of the failed test phase; additional information is provided for each phase.

....
skippedPhases

212

Id:0900d80580627a91

A50016-G5100-B333-04-7619

BS-4x / 82 II / 240 / 241 / 240XL commands

COBA

phaseId =

It represents the list of the skipped phases; they are


displayed only for test stopped during it execution.

phaseId =
....
poprosedRepair Action
=

A list of most probable fail probable causes is shown


(max four messages)

Operation Failed
This NACK-message occurs in the following cases: Message cannot be performed, test
not supported, capacity restrictions, physical configuration cannot be performed, object
not locked.
Application Guidelines:

In phase 3 COBA must be locked previous to the command

Perftest for COBA:0 in phase 2 only

Example of Command Execution:


Perftest COBA:NAME=RACK:0/COBA:0;

SET COBA
SET COBA

NAME=RACK:0..7/COBA:0..1 [,ALRMCOUNTER=]
[,ALRMT1/2/3=] [,EFCUSUP=];

Command Tree:
MANAGED-ELEMENT h BSS-EQUIPMENT h BTSEP h RACK h COBA h SET
COBA
Applicability:
Phase 2 and Phase 3.
Visibility level: 2.
Command Description:
This command permits modification of the attributes of the COBA (Core Basis module).
Long Names:
NAME

Address of the managed object

ALRMCOUNTER

alarmCount

ALRMT1/2/3

alarmTiming1(sec)/alarmTiming2(sec)/alarmTiming3(5 minutes units)

EFCUSUP

enableFcuSupport

System Responses:
Operation Completed
After command execution, a message of Changed Attribute Event Report is displayed.
A further message indicates the result of the operation. An example of set command is
the following:

A50016-G5100-B333-04-7619

Id:0900d80580627a91

213

COBA

BS-4x / 82 II / 240 / 241 / 240XL commands

JOB: 172
PC Time&Date: 16:47:25 03/23/2005
NE Time&Date: 16:45:19 09/15/2004
USER NAME:

User_Cindy

COMMAND:

Set COBA:NAME=RACK:0/COBA:1;

SW RELEASE:

01-04-17-01-26-51_05-02-23

COMMAND RESULT: Operation successful


END OF OUTPUT FOR JOB 172
Operation Failed
The specified attributes have not been set. In addition to the general NACK causes, a
specific NACK cause, which indicates that the command is inconsistent with the
physical configuration, is possible.
Application Guidelines:

The alarm evaluation on BTSE for the layer 1 is based on an "Errored Second"
concept. I.e.: If an error is found active (counted every 2 msec.) for x times (x = 5 for
"No signal", "AIS", "Loss of frame alignment ...) within 1 second, the whole second
is declared faulty otherwise the second is declared as "good". If one "Errored
Second" is detected, the subsequent seconds will be also declared faulty until no
error is detected within one second. This means that the layer 1 alarm handling is
very sensitive. With the default setting of "ALRMT2" which is 1 second a short interruption of 10 msec will cause an alarm generated by the BTSE. In order to increase
the tolerance of the BTSE layer 1 alarm handling against short interruptions on the
lines, the operator can change the value of the timer "ALRMT2" from the default
setting (1 second) to a higher value (e.g. 2 seconds). Nevertheless if the BTSE generates a layer 1 alarm no further actions are performed. Call processing is not inhibited as long as the layer 2 is up or the BSC does not declare the line disabled.

The behaviour of COBA2P8 and COBA4P12 is different, when attribute enableFCUSupport is TRUE and POWER OFF/ON of the COBA board is done. In case of
COBA2P8 the alarm 32805 - DM request a core reset is visible. In case of
COBA4P12 no alarm is visible

Example of Command Execution:


Set COBA:NAME=RACK:0/COBA:0,ACPER=20&ALRMCOUNTER=32,ALRMT1=20,
ALRMT2=2,ALRMT3=1,EFCUSUP=TRUE;

STOPTEST COBA
STOPTEST COBA

NAME=RACK:0..7/COBA:0..1;

Command Tree:
MANAGED-ELEMENT h BSS-EQUIPMENT h BTSEP h RACK h COBA h
STOPTEST COBA

214

Id:0900d80580627a91

A50016-G5100-B333-04-7619

BS-4x / 82 II / 240 / 241 / 240XL commands

COBA

Applicability:
Phase 2 and Phase 3.
Visibility level: 1.
Command Description:
This command is used to stop a diagnostic previously started.
Long Names:
NAME

Address of the managed object

System Responses:
Operation Completed
Test has been stopped. The System Responses will not be addressed to the MOT but
to the object BTSEP.

Result TEST:
name =

TEST:<n>

testOutcome =

inconclusive

mOts =

It is the identifier of the hardware object under test.

testTermination =

Cancel

executedPhases
phaseId =

It represents the list of the executed test phases; the


list is not shown for test in the waiting list (queued).

...
.
failedPhases
phaseId =

It represents the list of the failed test phase;

phaseId =

additional information is provided for each phase.

....
skippedPhases
phaseId =

It represents the list of the skipped phases;the list is


not shown for test in the waiting list (queued).

phaseId =
Operation Failed

Test has not been stopped. This NACK-message can occur when the specified test is
not running or in case of test which cannot be stopped.
Application Guidelines:
None.
Example of Command Execution:
Stoptest COBA:NAME=RACK:0/COBA:0;

A50016-G5100-B333-04-7619

Id:0900d80580627a91

215

COBA

BS-4x / 82 II / 240 / 241 / 240XL commands

SWITCH COBA
SWITCH COBA

NAME=RACK:0..7/COBA:0..1;

Command Tree:
MANAGED-ELEMENT h BSS-EQUIPMENT h BTSEP h RACK h COBA h
SWITCH COBA
Applicability:
Phase 2 and Phase 3.
Visibility level: 1.
Command Description:
This command is used to switch to the standby copy of COBA.
Long Names:
NAME

Address of the managed object

System Responses:
Operation Completed
JOB: 60
PC Time&Date: 11:57:24 03/23/2005
NE Time&Date: 12:58:59 09/15/2004
USER NAME:

User_Cindy

COMMAND:

Switch COBA:NAME=RACK:0/COBA:0;

SW RELEASE:

01-04-17-01-26-51_05-02-23

COMMAND RESULT: Operation successful


END OF OUTPUT FOR JOB 60
Operation Failed
JOB: 61
PC Time&Date: 11:57:31 03/23/2005
NE Time&Date: 12:59:06 09/15/2004
USER NAME:

User_Cindy

COMMAND:

Switch COBA:NAME=RACK:0/COBA:0;

SW RELEASE:

01-04-17-01-26-51_05-02-23

COMMAND RESULT: OPERATION FAILED

216

Id:0900d80580627a91

A50016-G5100-B333-04-7619

BS-4x / 82 II / 240 / 241 / 240XL commands

COBA

no redundant core board available (-173)


END OF OUTPUT FOR JOB 61
Application Guidelines:

Only COBA:0 can be switched

No redundancy present in BS82II (the command is not applicable)

Example of Command Execution:


Switch COBA:NAME=RACK:0/COBA:0;

UNLOCK COBA
UNLOCK COBA

NAME=RACK:0..7/COBA:0..1;

Command Tree:
MANAGED-ELEMENT h BSS-EQUIPMENT h BTSEP h RACK h COBA h
UNLOCK COBA
Applicability:
Phase 2 and Phase 3.
Visibility level: 1.
Command Description:
This command changes the administrative state of the COBA (Core Basis module).
Long Names:
NAME

Address of the managed object

System Responses:
Operation Completed
The specified change of administrative state has been perfomed:
JOB: 173
PC Time&Date: 16:47:33 03/23/2005
NE Time&Date: 16:45:27 09/15/2004
USER NAME:

User_Cindy

COMMAND:

Unlock COBA:NAME=RACK:0/COBA:1;

SW RELEASE:

01-04-17-01-26-51_05-02-23

COMMAND RESULT: Operation successful


administrativeState = Unlocked

A50016-G5100-B333-04-7619

Id:0900d80580627a91

217

COBA

BS-4x / 82 II / 240 / 241 / 240XL commands

END OF OUTPUT FOR JOB 173

CHANGED STATE EVENT REPORT:


This provides information about the administrative state, the operational state and the
availability status every time a state change occurs:
JOB: 174
PC Time&Date: 16:47:33 03/23/2005
NE Time&Date: 16:45:27 09/15/2004
USER NAME:

User_Cindy

SW RELEASE:

01-04-17-01-26-51_05-02-23

COMMAND RESULT: Operation successful


CHANGED STATE EVENT REPORT:
NAME = RACK:0/COBA:1
Administrative State = UNLOCKED
Notification Identifier = 556
END OF OUTPUT FOR JOB 174
Operation Failed
The specified change of administrative state has not been performed.
Application Guidelines:

Unlock COBA:0 only in phase 2

Example of Command Execution:


Unlock COBA:NAME=RACK:0/COBA:0;

218

Id:0900d80580627a91

A50016-G5100-B333-04-7619

BS-4x / 82 II / 240 / 241 / 240XL commands

COBAETHINTF

COBAETHINTF
The object represents the Ethernet interface of the new COBA which is connected to the
Zarlink device. It is introduced to configure/retrieve Ethernet interface specific information (similar to UNIX eth<x>) and to indicate state information.
The object is automatically created if a new COBA with CES support is equipped.

GET COBAETHINTF
GET COBAETHINTF

NAME=COBAETHINTF:0..0 [,REQATTL=ALS, AST, AVS,


OST, PRS, RELFUNCOBJ, MACADDR, TYPOFETH];

Command Tree:
MANAGED-ELEMENT h BSS-EQUIPMENT h BTSEP h COBAETHINTF h GET
COBAETHINTF
Applicability:
Phase 2 and Phase 3.
Visibility level: 0.
Command Description:
This command displays the attributes of the COBAETHINTF.
Long Names:
NAME

Address of the managed object

REQATTL

Required attribute list

ALS

alarmStatus

AST

administrativeState

AVS

availabilityStatus

OST

operationalState

PRS

proceduralStatus

RELFUNCOBJ

relatedFuncObjects

MACADDR

macAddress

TYPOFETH

typeOfEthernet

System Responses:
Operation Completed
A message indicates the result of the operation. An example of get command is the following:
JOB: 65
PC Time&Date: 02.04.2008 09:11:51 +02:00
NE Time&Date: 01.01.1990 18:27:29 +00:00
USER NAME:

A50016-G5100-B333-04-7619

User_Ross

Id:0900d805805944b4

219

COBAETHINTF

BS-4x / 82 II / 240 / 241 / 240XL commands

COMMAND:

Get COBAETHINTF:NAME=COBAETHINTF:0;

SW RELEASE:

01-04-19-01-08-CR_08-03-31

COMMAND RESULT: Operation successful

alarmStatus = CLEARED
administrativeState = Unlocked
availabilityStatus = NULL
operationalState = ENABLED
proceduralStatus = NULL
macAddress = "08:00:06:78:64:63"
typeOfEthernet = ethernet_II
END OF OUTPUT FOR JOB 65
Operation Failed
None.
Application Guidelines:
None.
Example of Command Execution:
Get COBAETHINTF:NAME=COBAETHINTF:0,
REQATTL=ALS&AST&AVS&OST&PRS&RELFUNCOBJ& MACADDR&TYPOFETH;

LOCK COBAETHINTF
LOCK COBAETHINTF

NAME=COBAETHINTF:0..0;

Command Tree:
MANAGED-ELEMENT h BSS-EQUIPMENT h BTSEP h COBAETHINTF h
LOCK COBAETHINTF
Applicability:
Phase 2.
Visibility level: 1.
Command Description:
This command changes the administrative state of COBAETHINTF.
Long Names:
NAME

Address of the managed object

System Responses:
Operation Completed
The specified change of administrative state has been perfomed:

220

Id:0900d805805944b4

A50016-G5100-B333-04-7619

BS-4x / 82 II / 240 / 241 / 240XL commands

COBAETHINTF

JOB: 89
PC Time&Date: 05.06.2008 13:18:01 +02:00
NE Time&Date: 01.01.1990 00:14:45 +00:00
USER NAME:

User_Ross

COMMAND:

Lock COBAETHINTF:NAME=COBAETHINTF:0;

SW RELEASE:

01-04-19-01-09-ZS_08-06-03

COMMAND RESULT: Operation successful

administrativeState = Locked
END OF OUTPUT FOR JOB 89
Operation Failed
None.
Application Guidelines:
None.
Example of Command Execution:
Lock COBAETHINTF:NAME=COBAETHINTF:0;

SET COBAETHINTF
SET COBAETHINTF

NAME=COBAETHINTF:0..0 [,TYPOFETH=];

Command Tree:
MANAGED-ELEMENT h BSS-EQUIPMENT h BTSEP h COBAETHINTF h SET
COBAETHINTF
Applicability:
Phase 2.
Visibility level: 2.
Command Description:
This command sets the attributes of COBAETHINTF.
Long Names:
NAME

Address of the managed object

TYPOFETH

typeOfEthernet

System Responses:
Operation Completed

A50016-G5100-B333-04-7619

Id:0900d805805944b4

221

COBAETHINTF

BS-4x / 82 II / 240 / 241 / 240XL commands

After command execution, a message of Changed Attribute Event Report is displayed.


A further message indicates the result of the operation. An example of set command is
the following:
JOB: 35
PC Time&Date: 11.02.2008 11:34:29 +01:00
NE Time&Date: 01.01.1990 00:40:35 +00:00
USER NAME:

User_Ross

COMMAND:

Set COBAETHINTF:NAME=COBAETHINTF:0,TETH=ethernet_II;

SW RELEASE:

01-04-19-01-01-CR_08-01-11

COMMAND RESULT: Operation successful

typeOfEthernet = ethernet_II
END OF OUTPUT FOR JOB 35
Operation Failed
None.
Application Guidelines:
None.
Example of Command Execution:
Set COBAETHINTF:NAME=COBAETHINTF:0,TYPOFETH=ethernet_II;

UNLOCK COBAETHINTF
UNLOCK
COBAETHINTF

NAME=COBAETHINTF:0..0;

Command Tree:
MANAGED-ELEMENT h BSS-EQUIPMENT h BTSEP h COBAETHINTF h
UNLOCK COBAETHINTF
Applicability:
Phase 2.
Visibility level: 1.
Command Description:
This command changes the administrative state of COBAETHINTF.
Long Names:
NAME

222

Address of the managed object

Id:0900d805805944b4

A50016-G5100-B333-04-7619

BS-4x / 82 II / 240 / 241 / 240XL commands

COBAETHINTF

System Responses:
Operation Completed
The specified change of administrative state has been perfomed:
JOB: 98
PC Time&Date: 05.06.2008 13:18:14 +02:00
NE Time&Date: 01.01.1990 00:14:58 +00:00
USER NAME:

User_Ross

COMMAND:

Unlock COBAETHINTF:NAME=COBAETHINTF:0;

SW RELEASE:

01-04-19-01-09-ZS_08-06-03

COMMAND RESULT: Operation successful

administrativeState = Unlocked
END OF OUTPUT FOR JOB 98
Operation Failed
None.
Application Guidelines:
None.
Example of Command Execution:
Unlock COBAETHINTF:NAME=COBAETHINTF:0;

A50016-G5100-B333-04-7619

Id:0900d805805944b4

223

COSA

BS-4x / 82 II / 240 / 241 / 240XL commands

COSA
The COSA (Core Satellite Interface module) object is the core controller expansion unit
and it is contained in the base rack only.

CREATE COSA
CREATE COSA

NAME=RACK:0..7/COSA:0..1;

Command Tree:
MANAGED-ELEMENT h BSS-EQUIPMENT h BTSEP h RACK h COSA h
CREATE COSA
Applicability:
Phase 2 and Phase 3.
Visibility level: 2.
Command Description:
This command adds the COSA (Core Satellite interface module) to the BTSE data base.
Long Names:
NAME

Address of the managed object

System Responses:
Operation Completed
After command execution, a message of Changed Configuration Notification is displayed.
A further message indicates the result of the operation. An example of create command
is the following:
JOB: 146
PC Time&Date: 16:44:39 03/23/2005
NE Time&Date: 16:42:33 09/15/2004
USER NAME:

User_Ross

SW RELEASE:

01-04-17-01-26-51_05-02-23

COMMAND RESULT: Operation successful


ChangedConfigurationNotification:
name = RACK:0/COSA:1
ChangeInfo = created
END OF OUTPUT FOR JOB 146

224

Id:0900d805805944b6

A50016-G5100-B333-04-7619

BS-4x / 82 II / 240 / 241 / 240XL commands

COSA

JOB: 147
PC Time&Date: 16:44:39 03/23/2005
NE Time&Date: 16:42:33 09/15/2004
USER NAME:

User_Ross

COMMAND:

Create COSA:NAME=RACK:0/COSA:1;

SW RELEASE:

01-04-17-01-26-51_05-02-23

COMMAND RESULT: Operation successful


END OF OUTPUT FOR JOB 147
Operation Failed
The specified Object has not been created. In addition to the general NACK causes, a
specific NACK cause, which indicates that the command is inconsistent with the
physical configuration, is possible. An example is the following:
JOB: 70
PC Time&Date: 16:37:54 03/23/2005
NE Time&Date: 16:35:47 09/15/2004
USER NAME:

User_Ross

COMMAND:

Create COSA:NAME=RACK:0/COSA:1;

SW RELEASE:

01-04-17-01-26-51_05-02-23

COMMAND RESULT: OPERATION FAILED


Object instance unknown (-9)
END OF OUTPUT FOR JOB 70
Application Guidelines:

No COSA creation in BS82II

Example of Command Execution:


Create COSA:NAME=RACK:0/COSA:0;

DELETE COSA
DELETE COSA

A50016-G5100-B333-04-7619

NAME=RACK:0..7/COSA:0..1;

Id:0900d805805944b6

225

COSA

BS-4x / 82 II / 240 / 241 / 240XL commands

Command Tree:
MANAGED-ELEMENT h BSS-EQUIPMENT h BTSEP h RACK h COSA h
DELETE COSA
Applicability:
Phase 2 and Phase 3.
Visibility level: 2.
Command Description:
This command deletes the COSA (Core Satellite interface module) from the BTSE data
base.
Long Names:
NAME

Address of the managed object

System Responses:
Operation Completed
After command execution, a message of Changed Configuration Notification is displayed. A further message indicates the result of the operation. An example of delete
command is the following:
JOB: 156
PC Time&Date: 16:45:32 03/23/2005
NE Time&Date: 16:43:26 09/15/2004
USER NAME:

User_Ross

SW RELEASE:

01-04-17-01-26-51_05-02-23

COMMAND RESULT: Operation successful


ChangedConfigurationNotification:
name = RACK:0/COSA:1
ChangeInfo = deleted
END OF OUTPUT FOR JOB 156
JOB: 157
PC Time&Date: 16:45:32 03/23/2005
NE Time&Date: 16:43:26 09/15/2004
USER NAME:

226

User_Ross

Id:0900d805805944b6

A50016-G5100-B333-04-7619

BS-4x / 82 II / 240 / 241 / 240XL commands

COMMAND:

COSA

Delete COSA:NAME=RACK:0/COSA:1;

SW RELEASE:

01-04-17-01-26-51_05-02-23

COMMAND RESULT: Operation successful


END OF OUTPUT FOR JOB 157
Operation Failed
The specified Object has not been deleted. Additionally to the general NACK causes, a
specific NACK cause, meaning that the command is inconsistent with physical configuration, is possible.
Application Guidelines:

COSA must be locked in Phase 3 before deletion

Example of Command Execution:


Delete COSA:NAME=RACK:0/COSA:0;

GET COSA
GET COSA

NAME=RACK:0..7/COSA:0..1 [,REQATTL=ALS, AST, AVS,


OST, PRS, RELFUNCOBJ, SLOTNO, STDBYST];

Command Tree:
MANAGED-ELEMENT h BSS-EQUIPMENT h BTSEP h RACK h COSA h
GET COSA
Applicability:
Phase 2 and Phase 3.
Visibility level: 0.
Command Description:
This command displays the attributes of the COSA (Core Satellite interface module).
Long Names:
NAME

Address of the managed object

REQATTL

Required attribute list

ALS

alarmStatus

AST

administrativeState

AVS

availabilityStatus

OST

operationalState

PRS

proceduralStatus

RELFUNCOBJ

relatedFuncObjects

SLOTNO

slotNo

STDBYST

standbyStatus

System Responses:
Operation Completed

A50016-G5100-B333-04-7619

Id:0900d805805944b6

227

COSA

BS-4x / 82 II / 240 / 241 / 240XL commands

A message indicates the result of the operation. An example of get command is the following:
JOB: 148
PC Time&Date: 16:45:02 03/23/2005
NE Time&Date: 16:42:56 09/15/2004
USER NAME:

User_Ross

COMMAND:

Get COSA:NAME=RACK:0/COSA:1;

SW RELEASE:

01-04-17-01-26-51_05-02-23

COMMAND RESULT: Operation successful


alarmStatus = CLEARED
administrativeState = Unlocked
availabilityStatus = NotInstalled
operationalState = DISABLED
proceduralStatus = NULL
relatedFuncObjects =
slotNo = leftCOSA
standbyStatus = NULL
END OF OUTPUT FOR JOB 148
Operation Failed
The GET command has not been successfully executed. A general NACK will indicate
possible errors or a specific NACK strictly related to the single command is possible.
Application Guidelines:

COSA:0 is the one with "Providing Service" Status, COSA:1 is in Standby Status

Example of Command Execution:


Get COSA:NAME=RACK:0/COSA:0,REQATTL=ALS&AST&AVS&
RELFUNCOBJ&OST& PRS.

GETTEST COSA
GETTEST COSA

NAME=RACK:0..7/COSA:0..1;

Command Tree:
MANAGED-ELEMENT h BSS-EQUIPMENT h BTSEP h RACK h COSA h
GETTEST COSA

228

Id:0900d805805944b6

A50016-G5100-B333-04-7619

BS-4x / 82 II / 240 / 241 / 240XL commands

COSA

Applicability:
Phase 2 and Phase 3.
Visibility level: 0.
Command Description:
This command displays the attributes of the COSA test.
Long Names:
NAME

Address of the managed object

REQATTL

Required attribute list

System Responses:
Operation Completed
A message indicates the result of the operation. An example of gettest command is the
following:
JOB: 193
PC Time&Date: 12:08:22 03/23/2005
NE Time&Date: 13:09:33 09/15/2004
USER NAME:

User_Ross

COMMAND:

Gettest COSA:NAME=RACK:0/COSA:0;

SW RELEASE:

01-04-17-01-26-51_05-02-23

COMMAND RESULT: Operation successful


MOT = RACK:0/COSA:0
testMonitor =
phaseId = PreliminaryTestsCosa
phaseStatus = Running
phaseId = CheckAlarmStatusCosa
phaseStatus = Waiting
phaseId = EndTestCosa
phaseStatus = Waiting
testOutcome = INCONCLUSIVE
testState = INITIALIZING
END OF OUTPUT FOR JOB 193
Operation Failed
The GET command has not been successfully executed. A general NACK will indicate
possible errors or a specific NACK strictly related to the single command is possible.

A50016-G5100-B333-04-7619

Id:0900d805805944b6

229

COSA

BS-4x / 82 II / 240 / 241 / 240XL commands

testMonitor
phaseId =
phaseStatus =

it is a list of all test phases related to the


selected object; for each phase the
related phaseStatus is provided (Passed,
Failed, Running or Waiting).

phaseId =
phaseStatus =
...
...
testOutcome

It represents the test result: it can be


Inconclusive (if the phases already
executed were successful) or Fail (if at
least one of the executed phases failed).

testState = Testing

It can assume one of the following values:


not_initialized, idle, initializing, suspended, testing, terminating and disabled.

Application Guidelines:
None.
Example of Command Execution:
Gettest COSA:NAME=RACK:0/COSA:0;

LOCK COSA
LOCK COSA

NAME=RACK:0..7/COSA:0..1;

Command Tree:
MANAGED-ELEMENT h BSS-EQUIPMENT h BTSEP h RACK h COSA h
LOCK COSA
Applicability:
Phase 2 and Phase 3.
Visibility level: 1.
Command Description:
This command changes the administrative state of COSA (Core Satellite interface
module).
Long Names:
NAME

Address of the managed object

System Responses:
Operation Completed
The specified change of administrative state has been perfomed:

230

Id:0900d805805944b6

A50016-G5100-B333-04-7619

BS-4x / 82 II / 240 / 241 / 240XL commands

COSA

JOB: 149
PC Time&Date: 16:45:07 03/23/2005
NE Time&Date: 16:43:01 09/15/2004
USER NAME:

User_Ross

COMMAND:

Lock COSA:NAME=RACK:0/COSA:1;

SW RELEASE:

01-04-17-01-26-51_05-02-23

COMMAND RESULT: Operation successful


administrativeState = Locked
END OF OUTPUT FOR JOB 149

CHANGED STATE EVENT REPORT:


This provides information about the administrative state, the operational state and the
availability status every time a state change occurs:
JOB: 150
PC Time&Date: 16:45:07 03/23/2005
NE Time&Date: 16:43:01 09/15/2004
USER NAME:

User_Ross

SW RELEASE:

01-04-17-01-26-51_05-02-23

COMMAND RESULT: Operation successful


CHANGED STATE EVENT REPORT:
NAME = RACK:0/COSA:1
Administrative State = LOCKED
Notification Identifier = 542
END OF OUTPUT FOR JOB 150
Operation Failed
The specified change of administrative state has not been performed.

A50016-G5100-B333-04-7619

Id:0900d805805944b6

231

COSA

BS-4x / 82 II / 240 / 241 / 240XL commands

Application Guidelines:
If the second line does not end in the first station (or is looped back by a plug!) also the
following points must considered for BS-240/241 and BS-40/41:

before a LOCK COSA command (over this board the information of the second line
is distributed within the BS-240/241 and BS-40/41) is applied by the operator, he
should lock the service distributed over the second line to this BTSE otherwise some
channels (associated to a COBA CU) remain enabled

in case of a defective COSA the channels which are associated to a COBA CU but
transported over the second line will remain enabled

While a Frequency Redefinition procedure is ongoing, the lock/unlock of all HMO's


actually related to a TRX is forbidden because that could lead to minor SELIC problem
or major SELIC problem alarms.
Example of Command Execution:
Lock COSA:NAME=RACK:0/COSA:0;

PERFTEST COSA
PERFTEST COSA

NAME=RACK:0..7/COSA:0..1;

Command Tree:
MANAGED-ELEMENT h BSS-EQUIPMENT h BTSEP h RACK h COSA h
PERFTEST COSA
Applicability:
Phase 2 and Phase 3.
Visibility level: 1.
Command Description:
This command is used to start an asynchronous test in COSA.
Long Names:
NAME

Address of the managed object

System Responses:
Operation Completed
Test configuration has been set and the specified test has been started. The System
response will not be addressed to the MOT but to the object BTSE.
JOB: 193
PC Time&Date: 12:08:42 03/23/2005
NE Time&Date: 13:09:41 09/15/2004

232

USER NAME:

User_Ross

COMMAND:

Perftest COSA:NAME=RACK:0/COSA:0;

Id:0900d805805944b6

A50016-G5100-B333-04-7619

BS-4x / 82 II / 240 / 241 / 240XL commands

SW RELEASE:

COSA

01-04-17-01-26-51_05-02-23

COMMAND RESULT: Operation successful


MOT = RACK:0/COSA:0
tO = BTSETEST:8
END OF OUTPUT FOR JOB 193
JOB: 194
PC Time&Date: 12:08:55 03/23/2005
NE Time&Date: 13:09:59 09/15/2004
USER NAME:

User_Ross

SW RELEASE:

01-04-17-01-26-51_05-02-23

COMMAND RESULT: Operation successful


ChangedConfigurationNotification:
name = BTSETEST:8
ChangeInfo = created
END OF OUTPUT FOR JOB 194
JOB: 195
PC Time&Date: 12:09:05 03/23/2005
NE Time&Date: 13:10:11 09/15/2004
USER NAME:

User_Ross

SW RELEASE:

01-04-17-01-26-51_05-02-23

COMMAND RESULT: Operation successful


CHANGED STATE EVENT REPORT:
NAME = RACK:0/COSA:0
Operational State = ENABLED
Availability Status = NULL_value
Standby Status = Cold_Standby

A50016-G5100-B333-04-7619

Id:0900d805805944b6

233

COSA

BS-4x / 82 II / 240 / 241 / 240XL commands

Notification Identifier = 220


END OF OUTPUT FOR JOB 195

JOB: 196
PC Time&Date: 12:09:16 03/23/2005
NE Time&Date: 13:10:22 09/15/2004
USER NAME:

User_Ross

SW RELEASE:

01-04-17-01-26-51_05-02-23

COMMAND RESULT: Operation successful


Test Report:
name = BTSETEST:8
testOutcome = PASSED
testTermination = Normal
MOT = RACK:0/COSA:0
executedPhases =
PreliminaryTestsCosa
SerialEepromTestCosa
EndTestCosa
END OF OUTPUT FOR JOB 196
JOB: 197
PC Time&Date: 12:09:23 03/23/2005
NE Time&Date: 13:10:34 09/15/2004
USER NAME:

User_Ross

SW RELEASE:

01-04-17-01-26-51_05-02-23

COMMAND RESULT: Operation successful


ChangedConfigurationNotification:
name = BTSETEST:8

234

Id:0900d805805944b6

A50016-G5100-B333-04-7619

BS-4x / 82 II / 240 / 241 / 240XL commands

COSA

ChangeInfo = deleted
END OF OUTPUT FOR JOB 197
The test results will be displayed at the end of the test phases.
Result TEST:
name =

TEST:<n>

testOutcome =

This field represents the test result; one of the following values can be displayed:
Pass

all the test phases are successfully


performed.

Inconclusive

the test is aborted by the system or


the test is terminated by the operator.

Fail

if at least one of the executed phases


fail.

mOts =

It is the identifier of the hardware object under test.

testTermination =

It specifies how the test is terminated, it can assume


the following values:
Normal

all the test phases are performed.

Abort

the test is aborted by system.

Cancel

the test is terminated by operator.

executedPhases
phaseId =
additionalWords =
....

It represents the list of the executed test phases (in


case of successful test result, all the test phases will
be listed).

failedPhases
phaseId =

It represents the list of the failed test phase; additional information is provided for each phase.

phaseId =
....
skippedPhases
phaseId =

It represents the list of the skipped phases; they are


displayed only for test stopped during it execution.

phaseId =
....
poprosedRepair Action
=

A list of most probable fail probable causes is shown


(max four messages)

Operation Failed

A50016-G5100-B333-04-7619

Id:0900d805805944b6

235

COSA

BS-4x / 82 II / 240 / 241 / 240XL commands

This NACK-message occurs in the following cases: Message cannot be performed, test
not supported, capacity restrictions, physical configuration cannot be performed, object
not locked.
Application Guidelines:

In phase 3 MO must be locked previous to the command execution

Example of Command Execution:


Perftest COSA:NAME=RACK:0/COSA:0;

STOPTEST COSA
STOPTEST COSA

NAME=RACK:0..7/COSA:0..1;

Command Tree:
MANAGED-ELEMENT h BSS-EQUIPMENT h BTSEP h RACK h COSA h
STOPTEST COSA
Applicability:
Phase 2 and Phase 3.
Visibility level: 1.
Command Description:
This command is used to stop a diagnostic previously started.
Long Names:
NAME

Address of the managed object

System Responses:
Operation Completed
Test has been stopped. The System Responses will not be addressed to the MOT but
to the object BTSEP.

Result TEST:
name =

TEST:<n>

testOutcome =

inconclusive

mOts =

It is the identifier of the hardware object under test.

testTermination =

Cancel

executedPhases
phaseId =
...
.

It represents the list of the executed test phases; the


list is not shown for test in the waiting list (queued).

failedPhases

236

Id:0900d805805944b6

A50016-G5100-B333-04-7619

BS-4x / 82 II / 240 / 241 / 240XL commands

COSA

phaseId =

It represents the list of the failed test phase;

phaseId =

additional information is provided for each phase.

....
skippedPhases
phaseId =

It represents the list of the skipped phases;the list is


not shown for test in the waiting list (queued).

phaseId =
Operation Failed

Test has not been stopped. This NACK-message can occur when the specified test is
not running or in case of test which cannot be stopped.
Application Guidelines:
None.
Example of Command Execution:
Stoptest COSA:NAME=RACK:0/COSA:0;

UNLOCK COSA
UNLOCK COSA

NAME=RACK:0..7/COSA:0..1;

Command Tree:
MANAGED-ELEMENT h BSS-EQUIPMENT h BTSEP h RACK h COSA h
UNLOCK COSA
Applicability:
Phase 2 and Phase 3.
Visibility level: 1.
Command Description:
This command changes the administrative state of COSA (Core Satellite interface
module).
Long Names:
NAME

Address of the managed object

System Responses:
Operation Completed
The specified change of administrative state has been perfomed:
JOB: 151
PC Time&Date: 16:45:12 03/23/2005
NE Time&Date: 16:43:06 09/15/2004
USER NAME:

A50016-G5100-B333-04-7619

User_Ross

Id:0900d805805944b6

237

COSA

BS-4x / 82 II / 240 / 241 / 240XL commands

COMMAND:

Unlock COSA:NAME=RACK:0/COSA:0;

SW RELEASE:

01-04-17-01-26-51_05-02-23

COMMAND RESULT: Operation successful


administrativeState = Unlocked
END OF OUTPUT FOR JOB 151

CHANGED STATE EVENT REPORT:


This provides information about the administrative state, the operational state and the
availability status every time a state change occurs:
JOB: 152
PC Time&Date: 16:45:12 03/23/2005
NE Time&Date: 16:43:06 09/15/2004
USER NAME:

User_Ross

SW RELEASE:

01-04-17-01-26-51_05-02-23

COMMAND RESULT: Operation successful


CHANGED STATE EVENT REPORT:
NAME = RACK:0/COSA:0
Administrative State = UNLOCKED
Standby Status = Providing_service
Notification Identifier = 543
END OF OUTPUT FOR JOB 152
Operation Failed
The specified change of administrative state has not been performed.
Application Guidelines:
While a Frequency Redefinition procedure is ongoing, the lock/unlock of all HMO's
actually related to a TRX is forbidden because that could lead to minor SELIC problem
or major SELIC problem alarms.
Example of Command Execution:
Unlock COSA:NAME=RACK:0/COSA:0;

238

Id:0900d805805944b6

A50016-G5100-B333-04-7619

BS-4x / 82 II / 240 / 241 / 240XL commands

CU

CU
The CU (Carrier Unit) represents the carrier hardware required for a TRX.

CREATE CU
CREATE CU

NAME=RACK:0..7/CU:0..11 [,RXLEVADJ=] [,TXLEVADJ=];

Command Tree:
MANAGED-ELEMENT h BSS-EQUIPMENT h BTSEP h RACK h CU h
CREATE CU
Applicability:
Phase 2 and Phase 3.
Visibility level: 2.
Command Description:
This command adds the CU (Carrier Unit) to the BTSE data base.
Long Names:
NAME

Address of the managed object

RXLEVADJ

rxLevAdjust(dB)

TXLEVADJ

txLevAdjust(dB)

System Responses:
Operation Completed
After command execution, a message of Changed Configuration Notification is displayed.
A further message indicates the result of the operation. An example of create command
is the following:
JOB: 124
PC Time&Date: 16:43:07 03/23/2005
NE Time&Date: 16:41:01 09/15/2004
USER NAME:

User_Rzan

SW RELEASE:

01-04-17-01-26-51_05-02-23

COMMAND RESULT: Operation successful


ChangedConfigurationNotification:
name = RACK:0/CU:0
ChangeInfo = created

A50016-G5100-B333-04-7619

Id:0900d805805944b8

239

CU

BS-4x / 82 II / 240 / 241 / 240XL commands

END OF OUTPUT FOR JOB 124


JOB: 125
PC Time&Date: 16:43:08 03/23/2005
NE Time&Date: 16:41:02 09/15/2004
USER NAME:

User_Rzan

COMMAND:

Create CU:NAME=RACK:0/CU:0;

SW RELEASE:

01-04-17-01-26-51_05-02-23

COMMAND RESULT: Operation successful


END OF OUTPUT FOR JOB 125
Operation Failed
The specified Object has not been created. In addition to the general NACK causes, a
specific NACK cause, which indicates that the command is inconsistent with the
physical configuration, is possible. An example is the following:
JOB: 69
PC Time&Date: 16:37:54 03/23/2005
NE Time&Date: 16:35:47 09/15/2004
USER NAME:

User_Rzan

COMMAND:

Create CU:NAME=RACK:0/CU:0;

SW RELEASE:

01-04-17-01-26-51_05-02-23

COMMAND RESULT: OPERATION FAILED


Object instance unknown (-9)
END OF OUTPUT FOR JOB 69
Application Guidelines:

When using the CLI interface for the RXLEVADJ parameter, the negative values
must be in brackets (see Examples of Command Execution)

Example of Command Execution:


Create CU:NAME=RACK:0/CU:0,RXLEVADJ=[-1]-0,TXLEVADJ=1;

240

Id:0900d805805944b8

A50016-G5100-B333-04-7619

BS-4x / 82 II / 240 / 241 / 240XL commands

CU

DELETE CU
DELETE CU

NAME=RACK:0..7/CU:0..11;

Command Tree:
MANAGED-ELEMENT h BSS-EQUIPMENT h BTSEP h RACK h CU h
DELETE CU
Applicability:
Phase 2 and Phase 3.
Visibility level: 2.
Command Description:
This command deletes the CU (Carrier Unit) from the BTSE data base.
Long Names:
NAME

Address of the managed object

System Responses:
Operation Completed
After command execution, a message of Changed Configuration Notification is displayed. A further message indicates the result of the operation. An example of delete
command is the following:
JOB: 138
PC Time&Date: 16:44:00 03/23/2005
NE Time&Date: 16:41:54 09/15/2004
USER NAME:

User_Rzan

SW RELEASE:

01-04-17-01-26-51_05-02-23

COMMAND RESULT: Operation successful


ChangedConfigurationNotification:
name = RACK:0/CU:0
ChangeInfo = deleted
END OF OUTPUT FOR JOB 138
JOB: 139
PC Time&Date: 16:44:00 03/23/2005
NE Time&Date: 16:41:54 09/15/2004

A50016-G5100-B333-04-7619

Id:0900d805805944b8

241

CU

BS-4x / 82 II / 240 / 241 / 240XL commands

USER NAME:

User_Rzan

COMMAND:

Delete CU:NAME=RACK:0/CU:0;

SW RELEASE:

01-04-17-01-26-51_05-02-23

COMMAND RESULT: Operation successful


END OF OUTPUT FOR JOB 139
Operation Failed
The specified Object has not been deleted. Additionally to the general NACK causes, a
specific NACK cause, meaning that the command is inconsistent with physical configuration, is possible.
Application Guidelines:

CU has to be locked in Phase 3 before deletion

Example of Command Execution:


Delete CU:NAME=RACK:0/CU:0;

GET CU
GET CU

NAME=RACK:0..7/CU:0..11 [,REQATTL=ALS, AST, AVS,


BSWVER, CCPBL, OST, OUTPUTPR, PRS, RELFUNCOBJ, RXLEVADJ, TXLEVADJ, FPGAFWVER, STDBYST];

Command Tree:
MANAGED-ELEMENT h BSS-EQUIPMENT h BTSEP h RACK h CU h GET
CU
Applicability:
Phase 2 and Phase 3.
Visibility level: 0.
Command Description:
This command displays the attributes of the CU (Carrier Unit).
Long Names:

242

NAME

Address of the managed object

REQATTL

Required attribute list

ALS

alarmStatus

AST

administrativeState

AVS

availabilityStatus

BSWVER

bootSoftwareVersion

CCPBL

carrierCapability

OST

operationalState

OUTPUTPR

outputPowerReduction

Id:0900d805805944b8

A50016-G5100-B333-04-7619

BS-4x / 82 II / 240 / 241 / 240XL commands

PRS

CU

proceduralStatus

RELFUNCOBJ

relatedFuncObjects

RXLEVADJ

rxLevAdjust(dB)

TXLEVADJ

txLevAdjust(dB)

FPGAFWVER
STDBYST

fpgaFwVer
standbyStatus

System Responses:
Operation Completed
A message indicates the result of the operation. An example of get command is the following:
JOB: 5
PC Time&Date: 26.06.2008 11:13:46 +02:00
NE Time&Date: 01.01.1990 00:13:10 +00:00
USER NAME:

User_Rzan

COMMAND:

Get CU:NAME=RACK:0/CU:0;

SW RELEASE:

01-04-19-01-09-01_08-06-2

COMMAND RESULT: Operation successful


alarmStatus = CLEARED
administrativeState = Unlocked
availabilityStatus = NULL
bootSoftwareVersion = "BTBBIX01.SWI:01-01-11-00-14-00_00-08-29"
carrierCapability = gsm
outputPowerReduction = 0
operationalState = ENABLED
proceduralStatus = NULL
relatedFuncObjects = Null
rxLevAdjust(dB) =
adjustValue = 0.0
adjustDivValue = 0.0
txLevAdjust(dB) = 0.0
standbyStatus = NULL
END OF OUTPUT FOR JOB 5
Operation Failed

A50016-G5100-B333-04-7619

Id:0900d805805944b8

243

CU

BS-4x / 82 II / 240 / 241 / 240XL commands

The GET command has not been successfully executed. A general NACK will indicate
possible errors or a specific NACK strictly related to the single command is possible.
Application Guidelines:

The value for the attribute GSM functional ID in LMT Phase 2 is "not configured"

CCPBL: After creation in advance of a CU object the attribute has the value
"unknown" in case of BTS Mainline or Xs. The value fourRXdiv is always used in
combination with either the value gsm or edge

FPGAFWVER attribute identifier cannot be present in the listOfRequiredAttributes


together with other attribute identifiers and it is not sent by the BTSE if a Get FCUMAIN/Get CU is done without the information element listOfRequiredAttributes

Example of Command Execution:


Get CU:NAME=RACK:0/CU:0,REQATTL=ALS&AST&AVS&BSWVER&CCPBL&OST&
OUTPUTPR&OST&PRS&RELFUNCOBJ&RXLEVADJ&TXLEVADJ&STDBYST;

GET CU FWID
GET CU FWID

NAME=RACK:0..7/CU:0..11;

Command Tree:
MANAGED-ELEMENT h BSS-EQUIPMENT h BTSEP h RACK h CU h GET
CU FWID
Applicability:
Phase 2 and Phase 3.
Visibility level: 0.
Command Description:
This command provides information on the FPGA FW images that are contained in the
boards flash prom together with an indication of the active version.
Up to 4 images are provided per board.
For FlexCUv2 or ECUv6 boards the FPGA FW versions are provided together with an
indication whether the FW version is the active one.
Long Names:
NAME

Address of the managed object

REQATTL

Required attribute list

System Responses:
Operation Completed
A message indicates the result of the operation. An example of get command is the following:
JOB: 6
PC Time&Date: 26.06.2008 11:13:51 +02:00

244

Id:0900d805805944b8

A50016-G5100-B333-04-7619

BS-4x / 82 II / 240 / 241 / 240XL commands

CU

NE Time&Date: 01.01.1990 00:13:15 +00:00


USER NAME:

User_Rzan

COMMAND:

Get CU FWID:NAME=RACK:0/CU:0;SW

RELEASE:

01-04-19-01-09-01_08-06-23

COMMAND RESULT:

Operation successful

fpgaFwVer = Null
END OF OUTPUT FOR JOB 6
Operation Failed
None.
Application Guidelines:
None.
Example of Command Execution:
Get CU FWID:NAME=RACK:0/CU:0,REQATTL=FPGAFWVER;

GET CU WIRING
GET CU WIRING

NAME=RACK:0..7/CU:0..11;

Command Tree:
MANAGED-ELEMENT h BSS-EQUIPMENT h BTSEP h RACK h CU h GET
CU WIRING
Applicability:
Phase 2 and Phase 3.
Visibility level: 0.
Command Description:
This command displays the attributes of the CU (Carrier Unit).
Long Names:
NAME

Address of the managed object

REQATTL

Required attribute list

System Responses:
Operation Completed
A message indicates the result of the operation. An example of get wiring command is
the following:
JOB: 127

A50016-G5100-B333-04-7619

Id:0900d805805944b8

245

CU

BS-4x / 82 II / 240 / 241 / 240XL commands

PC Time&Date: 16:43:13 03/23/2005


NE Time&Date: 16:41:07 09/15/2004
USER NAME:

User_Rzan

COMMAND:

Get CU WIRING:NAME=RACK:0/CU:0;

SW RELEASE:

01-04-17-01-26-51_05-02-23

COMMAND RESULT: Operation successful

cuWiring =
variable
rxNWiring = RACK:0/DULNA:0
END OF OUTPUT FOR JOB 127
Operation Failed
The GET command has not been successfully executed. A general NACK will indicate
possible errors or a specific NACK strictly related to the single command is possible.
Application Guidelines:

Refer to CUWIRING

Example of Command Execution:


Get CU WIRING:NAME=RACK:0/CU:0;

GETTEST CU
GETTEST CU

NAME=RACK:0..7/CU:0..11;

Command Tree:
MANAGED-ELEMENT h BSS-EQUIPMENT h BTSEP h RACK h CU h
GETTEST CU
Applicability:
Phase 2 and Phase 3.
Visibility level: 0.
Command Description:
This command displays the attributes of the object test.
Long Names:
NAME

Address of the managed object

REQATTL

Required attribute list

System Responses:
Operation Completed

246

Id:0900d805805944b8

A50016-G5100-B333-04-7619

BS-4x / 82 II / 240 / 241 / 240XL commands

CU

A message indicates the result of the operation. An example of gettest command is the
following:
JOB: 198
PC Time&Date: 12:11:08 03/23/2005
NE Time&Date: 13:12:44 09/15/2004
USER NAME:

User_Rzan

COMMAND:

Gettest CU:NAME=RACK:0/CU:0;

SW RELEASE:

01-04-17-01-26-51_05-02-23

COMMAND RESULT: Operation successful


MOT = RACK:0/CU:0
testMonitor =
phaseId = PreliminaryTestsCu
phaseStatus = Running
phaseId = CheckAlarmStatusCu
phaseStatus = Waiting
phaseId = EndTestCu
phaseStatus = Waiting
testOutcome = INCONCLUSIVE
testState = INITIALIZING
END OF OUTPUT FOR JOB 198
Operation Failed
The GET command has not been successfully executed. A general NACK will indicate
possible errors or a specific NACK strictly related to the single command is possible.
testMonitor
phaseId =
phaseStatus =

it is a list of all test phases related to the


selected object; for each phase the
related phaseStatus is provided (Passed,
Failed, Running or Waiting).

phaseId =
phaseStatus =
...
...
testOutcome

A50016-G5100-B333-04-7619

It represents the test result: it can be


Inconclusive (if the phases already
executed were successful) or Fail (if at
least one of the executed phases failed).

Id:0900d805805944b8

247

CU

BS-4x / 82 II / 240 / 241 / 240XL commands

testState = Testing

It can assume one of the following values:


not_initialized, idle, initializing, suspended, testing, terminating and disabled.

Application Guidelines:
None.
Example of Command Execution:
Gettest CU:NAME=RACK:0/CU:0;

LOCK CU
LOCK CU

NAME=RACK:0..7/CU:0..11;

Command Tree:
MANAGED-ELEMENT h BSS-EQUIPMENT h BTSEP h RACK h CU h LOCK
CU
Applicability:
Phase 2 and Phase 3.
Visibility level: 1.
Command Description:
This command changes the administrative state of CU (Carrier Unit).
Long Names:
NAME

Address of the managed object

System Responses:
Operation Completed
The specified change of administrative state has been perfomed:
JOB: 132
PC Time&Date: 16:43:41 03/23/2005
NE Time&Date: 16:41:35 09/15/2004
USER NAME:

User_Rzan

COMMAND:

Lock CU:NAME=RACK:0/CU:0;

SW RELEASE:

01-04-17-01-26-51_05-02-23

COMMAND RESULT: Operation successful


administrativeState = Locked

248

Id:0900d805805944b8

A50016-G5100-B333-04-7619

BS-4x / 82 II / 240 / 241 / 240XL commands

CU

END OF OUTPUT FOR JOB 132


CHANGED STATE EVENT REPORT:
This provides information about the administrative state, the operational state and the
availability status every time a state change occurs:
JOB: 133
PC Time&Date: 16:43:41 03/23/2005
NE Time&Date: 16:41:35 09/15/2004
USER NAME:

User_Rzan

SW RELEASE:

01-04-17-01-26-51_05-02-23

COMMAND RESULT: Operation successful


CHANGED STATE EVENT REPORT:
NAME = RACK:0/CU:0
Administrative State = LOCKED
Notification Identifier = 534
END OF OUTPUT FOR JOB 133
Operation Failed
The specified change of administrative state has not been performed.
Application Guidelines:
While a Frequency Redefinition procedure is ongoing, the lock/unlock of all HMO's
actually related to a TRX is forbidden because that could lead to minor SELIC problem
or major SELIC problem alarms.
Example of Command Execution:
Lock CU:NAME=RACK:0/CU:0;

PERFTEST CU
PERFTEST CU

NAME=RACK:0..7/CU:0..11;

Command Tree:
MANAGED-ELEMENT h BSS-EQUIPMENT h BTSEP h RACK h CU h
PERFTEST CU
Applicability:
Phase 2 and Phase 3.
Visibility level: 1.

A50016-G5100-B333-04-7619

Id:0900d805805944b8

249

CU

BS-4x / 82 II / 240 / 241 / 240XL commands

Command Description:
This command is used to start an asynchronous test in the object.
Long Names:
NAME

Address of the managed object

System Responses:
Operation Completed
Test configuration has been set and the specified test has been started. The System
response will not be addressed to the MOT but to the object BTSEP.
JOB: 199
PC Time&Date: 12:11:12 03/23/2005
NE Time&Date: 13:12:48 09/15/2004
USER NAME:

User_Rzan

COMMAND:

Perftest CU:NAME=RACK:0/CU:0;

SW RELEASE:

01-04-17-01-26-51_05-02-23

COMMAND RESULT: Operation successful


MOT = RACK:0/CU:0
tO = BTSETEST:1
END OF OUTPUT FOR JOB 199
JOB: 200
PC Time&Date: 12:11:12 03/23/2005
NE Time&Date: 13:12:48 09/15/2004
USER NAME:

User_Rzan

SW RELEASE:

01-04-17-01-26-51_05-02-23

COMMAND RESULT: Operation successful


ChangedConfigurationNotification:
name = BTSETEST:1
ChangeInfo = created
END OF OUTPUT FOR JOB 200

250

Id:0900d805805944b8

A50016-G5100-B333-04-7619

BS-4x / 82 II / 240 / 241 / 240XL commands

CU

JOB: 201
PC Time&Date: 12:11:12 03/23/2005
NE Time&Date: 13:12:59 09/15/2004
USER NAME:

User_Rzan

SW RELEASE:

01-04-17-01-26-51_05-02-23

COMMAND RESULT: Operation successful


CHANGED STATE EVENT REPORT:
NAME = RACK:0/CU:0
Operational State = ENABLED
Availability Status = NULL_value
Standby Status = Cold_Standby
Notification Identifier = 123
END OF OUTPUT FOR JOB 201

JOB: 202
PC Time&Date: 12:11:18 03/23/2005
NE Time&Date: 13:13:11 09/15/2004
USER NAME:

User_Rzan

SW RELEASE:

01-04-17-01-26-51_05-02-23

COMMAND RESULT: Operation successful


Test Report:
name = BTSETEST:1
testOutcome = PASSED
testTermination = Normal
MOT = RACK:0/CU:0
executedPhases =
PreliminaryTestsCu
SerialEepromTestCu

A50016-G5100-B333-04-7619

Id:0900d805805944b8

251

CU

BS-4x / 82 II / 240 / 241 / 240XL commands

EndTestCu
END OF OUTPUT FOR JOB 202
JOB: 203
PC Time&Date: 12:11:20 03/23/2005
NE Time&Date: 13:13:25 09/15/2004
USER NAME:

User_Rzan

SW RELEASE:

01-04-17-01-26-51_05-02-23

COMMAND RESULT: Operation successful


ChangedConfigurationNotification:
name = BTSETEST:1
ChangeInfo = deleted
END OF OUTPUT FOR JOB 203
The test results will be displayed at the end of the test phases.
Result TEST:
name =

TEST:<n>

testOutcome =

This field represents the test result; one of the following values can be displayed:
Pass

all the test phases are successfully


performed.

Inconclusive

the test is aborted by the system or


the test is terminated by the operator.

Fail

if at least one of the executed phases


fail.

mOts =

It is the identifier of the hardware object under test.

testTermination =

It specifies how the test is terminated, it can assume


the following values:
Normal

all the test phases are performed.

Abort

the test is aborted by system.

Cancel

the test is terminated by operator.

executedPhases

252

Id:0900d805805944b8

A50016-G5100-B333-04-7619

BS-4x / 82 II / 240 / 241 / 240XL commands

CU

phaseId =
additionalWords =
....

It represents the list of the executed test phases (in


case of successful test result, all the test phases will
be listed).

failedPhases
phaseId =

It represents the list of the failed test phase; additional information is provided for each phase.

phaseId =
....
skippedPhases
phaseId =

It represents the list of the skipped phases; they are


displayed only for test stopped during it execution.

phaseId =
....
poprosedRepair Action
=

A list of most probable fail probable causes is shown


(max four messages)

Operation Failed
This NACK-message occurs in the following cases: Message cannot be performed, test
not supported, capacity restrictions, physical configuration cannot be performed, object
not locked.
Application Guidelines:

In phase 3 MO must be locked previous to the command execution

Example of Command Execution:


Perftest CU:NAME=RACK:0/CU:0;

SET CU
SET CU

NAME=RACK:0..7/CU:0..11 [,RXLEVADJ=] [,TXLEVADJ=];

Command Tree:
MANAGED-ELEMENT h BSS-EQUIPMENT h BTSEP h RACK h CU h SET
CU
Applicability:
Phase 2 and Phase 3.
Visibility level: 2.
Command Description:
This command sets the attributes of CU (Carrier Unit) to the BTSE data base.
Long Names:
NAME

Address of the managed object

RXLEVADJ

rxLevAdjust(dB)

TXLEVADJ

txLevAdjust(dB)

A50016-G5100-B333-04-7619

Id:0900d805805944b8

253

CU

BS-4x / 82 II / 240 / 241 / 240XL commands

System Responses:
Operation Completed
After command execution, a message of Changed Attribute Event Report is displayed.
A further message indicates the result of the operation. An example of set command is
the following:
JOB: 131
PC Time&Date: 16:43:27 03/23/2005
NE Time&Date: 16:41:21 09/15/2004
USER NAME:

User_Rzan

COMMAND:

Set CU:NAME=RACK:0/CU:0;

SW RELEASE:

01-04-17-01-26-51_05-02-23

COMMAND RESULT: Operation successful


END OF OUTPUT FOR JOB 131
Operation Failed
The specified attributes have not been set. In addition to the general NACK causes, a
specific NACK cause, which indicates that the command is inconsistent with the
physical configuration, is possible.
Application Guidelines:

When using the CLI interface for the RXLEVADJ parameter, the negative values
must be in brackets (see Example of Command Execution)

The MGMSKOUTPUTP power reduction parameter is used for all existing high
power variants ECUxHPV2 and ECUxHPV3 (x= D or P)

Example of Command Execution:


Set CU:NAME=RACK:0/CU:0,TXLEVADJ=1,RXLEVADJ=[-1]-[-1];

STOPTEST CU
STOPTEST CU

NAME=RACK:0..7/CU:0..11;

Command Tree:
MANAGED-ELEMENT h BSS-EQUIPMENT h BTSEP h RACK h CU h
STOPTEST CU
Applicability:
Phase 2 and Phase 3.
Visibility level: 1.
Command Description:
This command is used to stop a diagnostic previously started.

254

Id:0900d805805944b8

A50016-G5100-B333-04-7619

BS-4x / 82 II / 240 / 241 / 240XL commands

CU

Long Names:
NAME

Address of the managed object

System Responses:
Operation Completed
Test has been stopped. The System Responses will not be addressed to the MOT but
to the object BTSEP.

Result TEST:
name =

TEST:<n>

testOutcome =

inconclusive

mOts =

It is the identifier of the hardware object under test.

testTermination =

Cancel

executedPhases
phaseId =

It represents the list of the executed test phases; the


list is not shown for test in the waiting list (queued).

...
.
failedPhases
phaseId =

It represents the list of the failed test phase;

phaseId =

additional information is provided for each phase.

....
skippedPhases
phaseId =

It represents the list of the skipped phases;the list is


not shown for test in the waiting list (queued).

phaseId =
Operation Failed

Test has not been stopped. This NACK-message can occur when the specified test is
not running or in case of test which cannot be stopped.
Application Guidelines:
None.
Example of Command Execution:
Stoptest CU:NAME=RACK:0/CU:0;

UNLOCK CU
UNLOCK CU

NAME=RACK:0..7/CU:0..11;

Command Tree:
MANAGED-ELEMENT h BSS-EQUIPMENT h BTSEP h RACK h CU h
UNLOCK CU

A50016-G5100-B333-04-7619

Id:0900d805805944b8

255

CU

BS-4x / 82 II / 240 / 241 / 240XL commands

Applicability:
Phase 2 and Phase 3.
Visibility level: 1.
Command Description:
This command changes the administrative state of CU (Carrier Unit).
Long Names:
NAME

Address of the managed object

System Responses:
Operation Completed
The specified change of administrative state has been perfomed:
JOB: 134
PC Time&Date: 16:43:50 03/23/2005
NE Time&Date: 16:41:44 09/15/2004
USER NAME:

User_Rzan

COMMAND:

Unlock CU:NAME=RACK:0/CU:0;

SW RELEASE:

01-04-17-01-26-51_05-02-23

COMMAND RESULT: Operation successful


administrativeState = Unlocked
END OF OUTPUT FOR JOB 134

CHANGED STATE EVENT REPORT:


This provides information about the administrative state, the operational state and the
availability status every time a state change occurs:
JOB: 135
PC Time&Date: 16:43:50 03/23/2005
NE Time&Date: 16:41:44 09/15/2004
USER NAME:

User_Rzan

SW RELEASE:

01-04-17-01-26-51_05-02-23

COMMAND RESULT: Operation successful

256

Id:0900d805805944b8

A50016-G5100-B333-04-7619

BS-4x / 82 II / 240 / 241 / 240XL commands

CU

CHANGED STATE EVENT REPORT:


NAME = RACK:0/CU:0
Administrative State = UNLOCKED
Notification Identifier = 535
END OF OUTPUT FOR JOB 135
Operation Failed
The specified change of administrative state has not been performed.
Application Guidelines:
While a Frequency Redefinition procedure is ongoing, the lock/unlock of all HMO's
actually related to a TRX is forbidden because that could lead to minor SELIC problem
or major SELIC problem alarms.
Example of Command Execution:
Unlock CU:NAME=RACK:0/CU:0;

A50016-G5100-B333-04-7619

Id:0900d805805944b8

257

DIDCTMA

BS-4x / 82 II / 240 / 241 / 240XL commands

DIDCTMA
The DIDCTMA object represents the power supply module of a TMA (Tower Mounted
Amplifier) connected to DIAMCO.

CREATE DIDCTMA
CREATE DIDCTMA

NAME=RACK:0..7/DIDCTMA:0..7;

Command Tree:
MANAGED-ELEMENT h BSS-EQUIPMENT h BTSEP h RACK h DIDCTMA h
CREATE DIDCTMA
Applicability:
Phase 2 and Phase 3.
Visibility level: 2.
Command Description:
This command adds the DIAMCO_DC_TMA (DC Power Supply Module of TMA) to the
BTSE data base.
Long Names:
NAME

Address of the managed object

System Responses:
Operation Completed
After command execution, a message of Changed Configuration Notification is displayed.
A further message indicates the result of the operation. An example of create command
is the following:
JOB: 111
PC Time&Date: 16:41:43 03/23/2005
NE Time&Date: 16:39:37 09/15/2004
USER NAME:

User_p

SW RELEASE:

01-04-17-01-26-51_05-02-23

COMMAND RESULT: Operation successful


ChangedConfigurationNotification:
name = RACK:0/DIDCTMA:0
ChangeInfo = created

258

Id:0900d805805944ba

A50016-G5100-B333-04-7619

BS-4x / 82 II / 240 / 241 / 240XL commands

DIDCTMA

END OF OUTPUT FOR JOB 111


JOB: 112
PC Time&Date: 16:41:43 03/23/2005
NE Time&Date: 16:39:37 09/15/2004
USER NAME:

User_p

COMMAND:

Create DIDCTMA:NAME=RACK:0/DIDCTMA:0;

SW RELEASE:

01-04-17-01-26-51_05-02-23

COMMAND RESULT: Operation successful


END OF OUTPUT FOR JOB 112
Operation Failed
The specified Object has not been created. In addition to the general NACK causes, a
specific NACK cause, which indicates that the command is inconsistent with the
physical configuration, is possible. An example is the following:
JOB: 68
PC Time&Date: 16:37:54 03/23/2005
NE Time&Date: 16:35:47 09/15/2004
USER NAME:

User_p

COMMAND:

Create DIDCTMA:NAME=RACK:0/DIDCTMA:0;

SW RELEASE:

01-04-17-01-26-51_05-02-23

COMMAND RESULT: OPERATION FAILED


Message cannot be performed (-17)
END OF OUTPUT FOR JOB 68
Application Guidelines:
None.
Example of Command Execution:
Create DIDCTMA:NAME=RACK:0/DIDCTMA:0;

DELETE DIDCTMA
DELETE DIDCTMA

A50016-G5100-B333-04-7619

NAME=RACK:0..7/DIDCTMA:0..7;

Id:0900d805805944ba

259

DIDCTMA

BS-4x / 82 II / 240 / 241 / 240XL commands

Command Tree:
MANAGED-ELEMENT h BSS-EQUIPMENT h BTSEP h RACK h DIDCTMA h
DELETE DIDCTMA
Applicability:
Phase 2 and Phase 3.
Visibility level: 2.
Command Description:
This command deletes the DIAMCO_DC_TMA (DC Power Supply Module of TMA) from
the BTSE data base.
Long Names:
NAME

Address of the managed object

System Responses:
Operation Completed
After command execution, a message of Changed Configuration Notification is displayed. A further message indicates the result of the operation. An example of delete
command is the following:
JOB: 120
PC Time&Date: 16:42:08 03/23/2005
NE Time&Date: 16:40:02 09/15/2004
USER NAME:

User_p

SW RELEASE:

01-04-17-01-26-51_05-02-23

COMMAND RESULT: Operation successful


ChangedConfigurationNotification:
name = RACK:0/DIDCTMA:0
ChangeInfo = deleted
END OF OUTPUT FOR JOB 120
JOB: 121
PC Time&Date: 16:42:08 03/23/2005
NE Time&Date: 16:40:02 09/15/2004
USER NAME:

260

User_p

Id:0900d805805944ba

A50016-G5100-B333-04-7619

BS-4x / 82 II / 240 / 241 / 240XL commands

COMMAND:

DIDCTMA

Delete DIDCTMA:NAME=RACK:0/DIDCTMA:0;

SW RELEASE:

01-04-17-01-26-51_05-02-23

COMMAND RESULT: Operation successful


END OF OUTPUT FOR JOB 121
Operation Failed
The specified Object has not been deleted. Additionally to the general NACK causes, a
specific NACK cause, meaning that the command is inconsistent with physical configuration, is possible.
Application Guidelines:

DIDCTMA must be locked in phase 3 before deletion

Example of Command Execution:


Delete DIDCTMA:NAME=RACK:0/DIDCTMA:0;

GET DIDCTMA
GET DIDCTMA

NAME=RACK:0..7/DIDCTMA:0..7 [,REQATTL=ALS, AST,


AVS, OST, PRS, RELFUNCOBJ];

Command Tree:
MANAGED-ELEMENT h BSS-EQUIPMENT h BTSEP h RACK h DIDCTMA h
GET DIDCTMA
Applicability:
Phase 2 and Phase 3.
Visibility level: 0.
Command Description:
This command displays the attributes of the DIAMCO_DC_TMA (DC Power Supply
Module of TMA).
Long Names:
NAME

Address of the managed object

REQATTL

Required attribute list

ALS

alarmStatus

AST

administrativeState

AVS

availabilityStatus

OST

operationalState

PRS

proceduralStatus

RELFUNCOBJ

relatedFuncObjects

System Responses:
Operation Completed

A50016-G5100-B333-04-7619

Id:0900d805805944ba

261

DIDCTMA

BS-4x / 82 II / 240 / 241 / 240XL commands

A message indicates the result of the operation. An example of get command is the following:
JOB: 113
PC Time&Date: 16:41:48 03/23/2005
NE Time&Date: 16:39:41 09/15/2004
USER NAME:

User_p

COMMAND:

Get DIDCTMA:NAME=RACK:0/DIDCTMA:0;

SW RELEASE:

01-04-17-01-26-51_05-02-23

COMMAND RESULT: Operation successful


alarmStatus = CLEARED
administrativeState = Unlocked
availabilityStatus = NotInstalled
operationalState = DISABLED
proceduralStatus = NULL
relatedFuncObjects =
END OF OUTPUT FOR JOB 113
Operation Failed
The GET command has not been successfully executed. A general NACK will indicate
possible errors or a specific NACK strictly related to the single command is possible.
Application Guidelines:
None.
Example of Command Execution:
Get DIDCTMA:NAME=RACK:0/DIDCTMA:0,REQATTL=ALS&AST&AVS&OST&PRS;

GETTEST DIDCTMA
GETTEST DIDCTMA

NAME=RACK:0..7/DIDCTMA:0..7;

Command Tree:
MANAGED-ELEMENT h BSS-EQUIPMENT h BTSEP h RACK h DIDCTMA h
GETTEST DIDCTMA
Applicability:
Phase 2 and Phase 3.
Visibility level: 0.

262

Id:0900d805805944ba

A50016-G5100-B333-04-7619

BS-4x / 82 II / 240 / 241 / 240XL commands

DIDCTMA

Command Description:
This command displays the attributes of the object test.
Long Names:
NAME

Address of the managed object

REQATTL

Required attribute list

System Responses:
Operation Completed
A message indicates the result of the operation. An example of gettest command is the
following:
JOB: 204
PC Time&Date: 12:11:28 03/23/2005
NE Time&Date: 13:13:04 09/15/2004
USER NAME:

User_p

COMMAND:

Gettest DIDCTMA:NAME=RACK:0/DIDCTMA:0;

SW RELEASE:

01-04-17-01-26-51_05-02-23

COMMAND RESULT: Operation successful


MOT = RACK:0/DIDCTMA:0
testMonitor =
phaseId = PreliminaryTestsDidctma
phaseStatus = Running
phaseId = CheckAlarmStatusDidctma
phaseStatus = Waiting
phaseId = EndTestDidctma
phaseStatus = Waiting
testOutcome = INCONCLUSIVE
testState = INITIALIZING
END OF OUTPUT FOR JOB 204
Operation Failed
The GET command has not been successfully executed. A general NACK will indicate
possible errors or a specific NACK strictly related to the single command is possible.

A50016-G5100-B333-04-7619

Id:0900d805805944ba

263

DIDCTMA

BS-4x / 82 II / 240 / 241 / 240XL commands

testMonitor
phaseId =
phaseStatus =

it is a list of all test phases related to the


selected object; for each phase the
related phaseStatus is provided (Passed,
Failed, Running or Waiting).

phaseId =
phaseStatus =
...
...
testOutcome

It represents the test result: it can be


Inconclusive (if the phases already
executed were successful) or Fail (if at
least one of the executed phases failed).

testState = Testing

It can assume one of the following values:


not_initialized, idle, initializing, suspended, testing, terminating and disabled.

Application Guidelines:
None.
Example of Command Execution:
Gettest DIDCTMA:NAME=RACK:0/DIDCTMA:0;

LOCK DIDCTMA
LOCK DIDCTMA

NAME=RACK:0..7/DIDCTMA:0..7;

Command Tree:
MANAGED-ELEMENT h BSS-EQUIPMENT h BTSEP h RACK h DIDCTMA h
LOCK DIDCTMA
Applicability:
Phase 2 and Phase 3.
Visibility level: 1.
Command Description:
This command changes the administrative state of DIAMCO_DC_TMA (DC Power
Supply Module of TMA).
Long Names:
NAME

Address of the managed object

System Responses:
Operation Completed
The specified change of administrative state has been perfomed:

264

Id:0900d805805944ba

A50016-G5100-B333-04-7619

BS-4x / 82 II / 240 / 241 / 240XL commands

DIDCTMA

JOB: 114
PC Time&Date: 16:41:53 03/23/2005
NE Time&Date: 16:39:47 09/15/2004
USER NAME:

User_p

COMMAND:

Lock DIDCTMA:NAME=RACK:0/DIDCTMA:0;

SW RELEASE:

01-04-17-01-26-51_05-02-23

COMMAND RESULT: Operation successful


administrativeState = Locked
END OF OUTPUT FOR JOB 114

CHANGED STATE EVENT REPORT:


This provides information about the administrative state, the operational state and the
availability status every time a state change occurs:
JOB: 115
PC Time&Date: 16:41:53 03/23/2005
NE Time&Date: 16:39:47 09/15/2004
USER NAME:

User_p

SW RELEASE:

01-04-17-01-26-51_05-02-23

COMMAND RESULT: Operation successful


CHANGED STATE EVENT REPORT:
NAME = RACK:0/DIDCTMA:0
Administrative State = LOCKED
Notification Identifier = 525
END OF OUTPUT FOR JOB 115
Operation Failed
The specified change of administrative state has not been performed.

A50016-G5100-B333-04-7619

Id:0900d805805944ba

265

DIDCTMA

BS-4x / 82 II / 240 / 241 / 240XL commands

Application Guidelines:
While a Frequency Redefinition procedure is ongoing, the lock/unlock of all HMO's
actually related to a TRX is forbidden because that could lead to minor SELIC problem
or major SELIC problem alarms.
Example of Command Execution:
Lock DIDCTMA:NAME=RACK:0/DIDCTMA:0;

PERFTEST DIDCTMA
PERFTEST DIDCTMA

NAME=RACK:0..7/DIDCTMA:0..7;

Command Tree:
MANAGED-ELEMENT h BSS-EQUIPMENT h BTSEP h RACK h DIDCTMA h
PERFTEST DIDCTMA
Applicability:
Phase 2 and Phase 3.
Visibility level: 1.
Command Description:
This command is used to start an asynchronous test in DIDCTMA.
Long Names:
NAME

Address of the managed object

System Responses:
Operation Completed
Test configuration has been set and the specified test has been started. The System
response will not be addressed to the MOT but to the object BTSEP.
JOB: 205
PC Time&Date: 12:13:07 03/23/2005
NE Time&Date: 13:14:42 09/15/2004
USER NAME:

User_p

COMMAND:

Perftest DIDCTMA:NAME=RACK:0/DIDCTMA:0;

SW RELEASE:

01-04-17-01-26-51_05-02-23

COMMAND RESULT: Operation successful


MOT = RACK:0/DIDCTMA:0
tO = BTSETEST:2
END OF OUTPUT FOR JOB 205

266

Id:0900d805805944ba

A50016-G5100-B333-04-7619

BS-4x / 82 II / 240 / 241 / 240XL commands

DIDCTMA

JOB: 206
PC Time&Date: 12:13:22 03/23/2005
NE Time&Date: 13:14:57 09/15/2004
USER NAME:

User_p

SW RELEASE:

01-04-17-01-26-51_05-02-23

COMMAND RESULT: Operation successful


ChangedConfigurationNotification:
name = BTSETEST:2
ChangeInfo = created
END OF OUTPUT FOR JOB 206
JOB: 207
PC Time&Date: 12:13:31 03/23/2005
NE Time&Date: 13:15:06 09/15/2004
USER NAME:

User_p

SW RELEASE:

01-04-17-01-26-51_05-02-23

COMMAND RESULT: Operation successful


CHANGED STATE EVENT REPORT:
NAME = RACK:0/DIDCTMA:0
Operational State = ENABLED
Availability Status = NULL_value
Standby Status = Cold_Standby
Notification Identifier = 146
END OF OUTPUT FOR JOB 207

JOB: 208

A50016-G5100-B333-04-7619

Id:0900d805805944ba

267

DIDCTMA

BS-4x / 82 II / 240 / 241 / 240XL commands

PC Time&Date: 12:13:35 03/23/2005


NE Time&Date: 13:15:10 09/15/2004
USER NAME:

User_p

SW RELEASE:

01-04-17-01-26-51_05-02-23

COMMAND RESULT: Operation successful


Test Report:
name = BTSETEST:2
testOutcome = PASSED
testTermination = Normal
MOT = RACK:0/DIDCTMA:0
executedPhases =
PreliminaryTestsDidctma
SerialEepromTestDidctma
EndTestDidctma
END OF OUTPUT FOR JOB 208
JOB: 209
PC Time&Date: 12:13:35 03/23/2005
NE Time&Date: 13:15:10 09/15/2004
USER NAME:

User_p

SW RELEASE:

01-04-17-01-26-51_05-02-23

COMMAND RESULT: Operation successful


ChangedConfigurationNotification:
name = BTSETEST:2
ChangeInfo = deleted
END OF OUTPUT FOR JOB 209
The test results will be displayed at the end of the test phases.
Result TEST:
name =

268

TEST:<n>

Id:0900d805805944ba

A50016-G5100-B333-04-7619

BS-4x / 82 II / 240 / 241 / 240XL commands

DIDCTMA

testOutcome =

This field represents the test result; one of the following values can be displayed:
Pass

all the test phases are successfully


performed.

Inconclusive

the test is aborted by the system or


the test is terminated by the operator.

Fail

if at least one of the executed phases


fail.

mOts =

It is the identifier of the hardware object under test.

testTermination =

It specifies how the test is terminated, it can assume


the following values:
Normal

all the test phases are performed.

Abort

the test is aborted by system.

Cancel

the test is terminated by operator.

executedPhases
phaseId =
additionalWords =
....

It represents the list of the executed test phases (in


case of successful test result, all the test phases will
be listed).

failedPhases
phaseId =

It represents the list of the failed test phase; additional information is provided for each phase.

phaseId =
....
skippedPhases
phaseId =

It represents the list of the skipped phases; they are


displayed only for test stopped during it execution.

phaseId =
....
poprosedRepair Action
=

A list of most probable fail probable causes is shown


(max four messages)

Operation Failed
This NACK-message occurs in the following cases: Message cannot be performed, test
not supported, capacity restrictions, physical configuration cannot be performed, object
not locked.
Application Guidelines:

In phase 3 MO must be locked previous to the command execution

Example of Command Execution:


Perftest DIDCTMA:NAME=RACK:0/DIDCTMA:0;

A50016-G5100-B333-04-7619

Id:0900d805805944ba

269

DIDCTMA

BS-4x / 82 II / 240 / 241 / 240XL commands

STOPTEST DIDCTMA
STOPTEST DIDCTMA

NAME=RACK:0..7/DIDCTMA:0..7;

Command Tree:
MANAGED-ELEMENT h BSS-EQUIPMENT h BTSEP h RACK h DIDCTMA h
STOPTEST DIDCTMA
Applicability:
Phase 2 and Phase 3.
Visibility level: 1.
Command Description:
This command is used to stop a diagnostic previously started.
Long Names:
NAME

Address of the managed object

System Responses:
Operation Completed
Test has been stopped. The System Responses will not be addressed to the MOT but
to the object BTSEP.

Result TEST:
name =

TEST:<n>

testOutcome =

inconclusive

mOts =

It is the identifier of the hardware object under test.

testTermination =

Cancel

executedPhases
phaseId =
...
.

It represents the list of the executed test phases; the


list is not shown for test in the waiting list (queued).

failedPhases
phaseId =

It represents the list of the failed test phase;

phaseId =

additional information is provided for each phase.

....
skippedPhases
phaseId =
phaseId =

It represents the list of the skipped phases;the list is


not shown for test in the waiting list (queued).

Operation Failed
Test has not been stopped. This NACK-message can occur when the specified test is
not running or in case of test which cannot be stopped.

270

Id:0900d805805944ba

A50016-G5100-B333-04-7619

BS-4x / 82 II / 240 / 241 / 240XL commands

DIDCTMA

Application Guidelines:
None.
Example of Command Execution:
Stoptest DIDCTMA:NAME=RACK:0/DIDCTMA:0;

UNLOCK DIDCTMA
UNLOCK DIDCTMA

NAME=RACK:0..7/DIDCTMA:0..7;

Command Tree:
MANAGED-ELEMENT h BSS-EQUIPMENT h BTSEP h RACK h DIDCTMA h
UNLOCK DIDCTMA
Applicability:
Phase 2 and Phase 3.
Visibility level: 1.
Command Description:
This command changes the administrative state of DIAMCO_DC_TMA (DC Power
Supply Module of TMA).
Long Names:
NAME

Address of the managed object

System Responses:
Operation Completed
The specified change of administrative state has been perfomed:
JOB: 116
PC Time&Date: 16:41:57 03/23/2005
NE Time&Date: 16:39:51 09/15/2004
USER NAME:

User_p

COMMAND:

Unlock DIDCTMA:NAME=RACK:0/DIDCTMA:0;

SW RELEASE:

01-04-17-01-26-51_05-02-23

COMMAND RESULT: Operation successful


administrativeState = Unlocked
END OF OUTPUT FOR JOB 116

CHANGED STATE EVENT REPORT:

A50016-G5100-B333-04-7619

Id:0900d805805944ba

271

DIDCTMA

BS-4x / 82 II / 240 / 241 / 240XL commands

This provides information about the administrative state, the operational state and the
availability status every time a state change occurs:
JOB: 117
PC Time&Date: 16:41:57 03/23/2005
NE Time&Date: 16:39:51 09/15/2004
USER NAME:

User_p

SW RELEASE:

01-04-17-01-26-51_05-02-23

COMMAND RESULT: Operation successful


CHANGED STATE EVENT REPORT:
NAME = RACK:0/DIDCTMA:0
Administrative State = UNLOCKED
Notification Identifier = 526
END OF OUTPUT FOR JOB 117
Operation Failed
The specified change of administrative state has not been performed.
Application Guidelines:
While a Frequency Redefinition procedure is ongoing, the lock/unlock of all HMO's
actually related to a TRX is forbidden because that could lead to minor SELIC problem
or major SELIC problem alarms.
Example of Command Execution:
Unlock DIDCTMA:NAME=RACK:0/DIDCTMA:0;

272

Id:0900d805805944ba

A50016-G5100-B333-04-7619

BS-4x / 82 II / 240 / 241 / 240XL commands

DILNA

DILNA
The DILNA object represents the low noise amplifier of DIAMCO (Diversity Antenna
Multicoupler).

CREATE DILNA
CREATE DILNA

NAME=RACK:0..7/DILNA:0..7 ,CELLNO= [,COMBMD=]


[,LNAPRED=] [,SCELLNO=] ,WDLNA=;

Command Tree:
MANAGED-ELEMENT h BSS-EQUIPMENT h BTSEP h RACK h DILNA h
CREATE DILNA
Applicability:
Phase 2 and Phase 3.
Visibility level: 2.
Command Description:
This command adds the DILNA (Low Noise Amplifier of Diversity Multicoupler) together
with its attributes to the BTSE data base.
Long Names:
NAME

Address of the managed object

CELLNO

cellNumber

COMBMD

combMode

LNAPRED

lnaPredecessor

SCELLNO

secondCellNumber

WDLNA

wiringDataLna

System Responses:
Operation Completed
After command execution, a message of Changed Configuration Notification is displayed.
A further message indicates the result of the operation. An example of create command
is the following:
JOB: 96
PC Time&Date: 16:40:26 03/23/2005
NE Time&Date: 16:38:20 09/15/2004
USER NAME:

User_q

SW RELEASE:

01-04-17-01-26-51_05-02-23

COMMAND RESULT: Operation successful

A50016-G5100-B333-04-7619

Id:0900d805805944bc

273

DILNA

BS-4x / 82 II / 240 / 241 / 240XL commands

ChangedConfigurationNotification:
name = RACK:0/DILNA:0
ChangeInfo = created
END OF OUTPUT FOR JOB 96
JOB: 97
PC Time&Date: 16:40:26 03/23/2005
NE Time&Date: 16:38:20 09/15/2004
USER NAME:

User_q

COMMAND:

Create DILNA:NAME=RACK:0/DILNA:0,CELLNO=1,WDLNA=CU0N;

SW RELEASE:

01-04-17-01-26-51_05-02-23

COMMAND RESULT: Operation successful


cellNumber = 1
secondCellNumber = 2
wiringDataLna = CU0N
END OF OUTPUT FOR JOB 97
Operation Failed
The specified Object has not been created. In addition to the general NACK causes, a
specific NACK cause, which indicates that the command is inconsistent with the
physical configuration, is possible. An example is the following:
JOB: 74
PC Time&Date: 16:37:54 03/23/2005
NE Time&Date: 16:35:47 09/15/2004
USER NAME:

User_q

COMMAND:

Create DILNA:NAME=RACK:0/DILNA:0,CELLNO=1,WDLNA=CU0N;

SW RELEASE:

01-04-17-01-26-51_05-02-23

COMMAND RESULT: OPERATION FAILED


Message cannot be performed (-17)

274

Id:0900d805805944bc

A50016-G5100-B333-04-7619

BS-4x / 82 II / 240 / 241 / 240XL commands

DILNA

END OF OUTPUT FOR JOB 74


Application Guidelines:

The DIAMCO_LNA and the CUs are in the same rack and belong to the same cell

Each CU has a 'normal path' RX input and a 'diversity path' RX input and the
operator must indicate which of them is wired to the DIAMCO_LNA

If there is no wiring the operator must not provide a value for the attribute LNAPRED
(if a get is done the attribute identifier will be put into the list of unavailable attributes)

If there is no wiring for the attribute LNAPRED and the operator enters a value, this
error can be corrected by a deletion of the object and a re-creation of the object

The BTSE SW doesn't check if the entered "predecessor (relative number)" is compatible with typeOfBTSE; e.g. an input of TMA 11 is not rejected in a BS40 although
BS40 allows only the creation of TMA 0-5
The BTSE SW doesn't check if the entered "predecessor (rack)" is compatible with
typeOfBTSE; e.g. an input of RACK 1 is not rejected in a BS40 although BS40
allows only the creation of RACK 0

Wildcard addressing is not possible

Example of Command Execution:


Create DILNA:NAME=RACK:1/DILNA:0,CELLNO=0,COMBMD=EightToTwo,
SCELLNO=2,WDLNA=CU0D&CU1D&CU2D&CU3D,
LNAPRED=TMA (RACK:0-TMA:0);

DELETE DILNA
DELETE DILNA

NAME=RACK:0..7/DILNA:0..7;

Command Tree:
MANAGED-ELEMENT h BSS-EQUIPMENT h BTSEP h RACK h DILNA h
DELETE DILNA
Applicability:
Phase 2 and Phase 3.
Visibility level: 2.
Command Description:
This command deletes the DILNA (Low Noise Amplifier of Diversity Multicoupler)
together with its attributes from the BTSE data base.
Long Names:
NAME

Address of the managed object

System Responses:
Operation Completed

A50016-G5100-B333-04-7619

Id:0900d805805944bc

275

DILNA

BS-4x / 82 II / 240 / 241 / 240XL commands

After command execution, a message of Changed Configuration Notification is displayed. A further message indicates the result of the operation. An example of delete
command is the following:
JOB: 106
PC Time&Date: 16:40:51 03/23/2005
NE Time&Date: 16:38:45 09/15/2004
USER NAME:

User_q

SW RELEASE:

01-04-17-01-26-51_05-02-23

COMMAND RESULT: Operation successful


ChangedConfigurationNotification:
name = RACK:0/DILNA:0
ChangeInfo = deleted
END OF OUTPUT FOR JOB 106
JOB: 107
PC Time&Date: 16:40:51 03/23/2005
NE Time&Date: 16:38:45 09/15/2004
USER NAME:

User_q

COMMAND:

Delete DILNA:NAME=RACK:0/DILNA:0;

SW RELEASE:

01-04-17-01-26-51_05-02-23

COMMAND RESULT: Operation successful


END OF OUTPUT FOR JOB 107
Operation Failed
The specified Object has not been deleted. Additionally to the general NACK causes, a
specific NACK cause, meaning that the command is inconsistent with physical configuration, is possible.
Application Guidelines:

276

DILNA must be locked in Phase 3, before deletion

If this object is deleted, the related TRXs are out of service

Id:0900d805805944bc

A50016-G5100-B333-04-7619

BS-4x / 82 II / 240 / 241 / 240XL commands

DILNA

Example of Command Execution:


Delete DILNA:NAME=RACK:0/DILNA:0;

GET DILNA
GET DILNA

NAME=RACK:0..7/DILNA:0..7 [,REQATTL=ALS, AST, AVS,


CELLNO, GNA, COMBMD, LNAMODE, LNAPRED, OST,
PRS, RELFUNCOBJ, SCELLNO, WDLNA];

Command Tree:
MANAGED-ELEMENT h BSS-EQUIPMENT h BTSEP h RACK h DILNA h
GET DILNA
Applicability:
Phase 2 and Phase 3.
Visibility level: 0.
Command Description:
This command displays the attributes of the DILNA (Low Noise Amplifier of Diversity
Multicoupler).
Long Names:
NAME

Address of the managed object

REQATTL

Required attribute list

ALS

alarmStatus

AST

administrativeState

AVS

availabilityStatus

CELLNO

cellNumber

GNA

gainAdjust(dB)

COMBMD

combMode

LNAMODE

lnaMode

LNAPRED

lnaPredecessor

OST

operationalState

PRS

proceduralStatus

RELFUNCOBJ

relatedFuncObjects

SCELLNO

secondCellNumber

WDLNA

wiringDataLna

System Responses:
Operation Completed
A message indicates the result of the operation. An example of get command is the following:
JOB: 99

A50016-G5100-B333-04-7619

Id:0900d805805944bc

277

DILNA

BS-4x / 82 II / 240 / 241 / 240XL commands

PC Time&Date: 16:40:32 03/23/2005


NE Time&Date: 16:38:26 09/15/2004
USER NAME:

User_q

COMMAND:

Get DILNA:NAME=RACK:0/DILNA:1;

SW RELEASE:

01-04-17-01-26-51_05-02-23

COMMAND RESULT: Operation successful

alarmStatus = CLEARED
administrativeState = Unlocked
availabilityStatus = NotInstalled
cellNumber = 1
cableLossAdjust(dB) = Null
combMode = EightToTwo
lnaMode = UNKNOWN
lnaPredecessor = Null
operationalState = DISABLED
proceduralStatus = NULL
relatedFuncObjects =
secondCellNumber = NotUsed
wiringDataLna = CU3N & CU2N & CU0D & CU0N
END OF OUTPUT FOR JOB 99
Operation Failed
The GET command has not been successfully executed. A general NACK will indicate
possible errors or a specific NACK strictly related to the single command is possible.
Application Guidelines:

The value for the attribute relatedFuncObjects in LMT Phase 2 is "not configured"

The value for proceduralStatus must be NULL

Example of Command Execution:


Get
DILNA:NAME=RACK:0/DILNA:0,REQATTL=ALS&AST&AVS&CELLNO&GNA&CLAD
J&COMBMD&LNAMODE&LNAPRED&OST&PRS&SCELLNO&WDLNA;

GETTEST DILNA
GETTEST DILNA

278

NAME=RACK:0..7/DILNA:0..7;

Id:0900d805805944bc

A50016-G5100-B333-04-7619

BS-4x / 82 II / 240 / 241 / 240XL commands

DILNA

Command Tree:
MANAGED-ELEMENT h BSS-EQUIPMENT h BTSEP h RACK h DILNA h
GETTEST DILNA
Applicability:
Phase 2 and Phase 3.
Visibility level: 0.
Command Description:
This command displays the attributes of the object test.
Long Names:
NAME

Address of the managed object

REQATTL

Required attribute list

System Responses:
Operation Completed
A message indicates the result of the operation. An example of gettest command is the
following:
JOB: 210
PC Time&Date: 12:13:35 03/23/2005
NE Time&Date: 13:15:10 09/15/2004
USER NAME:

User_q

COMMAND:

Gettest DILNA:NAME=RACK:0/DILNA:0;

SW RELEASE:

01-04-17-01-26-51_05-02-23

COMMAND RESULT: Operation successful


MOT = RACK:0/DILNA:0
testMonitor =
phaseId = PreliminaryTestsDilna
phaseStatus = Running
phaseId = CheckAlarmStatusDilna
phaseStatus = Waiting
phaseId = EndTestDilna
phaseStatus = Waiting
testOutcome = INCONCLUSIVE
testState = INITIALIZING
END OF OUTPUT FOR JOB 210

A50016-G5100-B333-04-7619

Id:0900d805805944bc

279

DILNA

BS-4x / 82 II / 240 / 241 / 240XL commands

Operation Failed
The GET command has not been successfully executed. A general NACK will indicate
possible errors or a specific NACK strictly related to the single command is possible.
testMonitor
phaseId =
phaseStatus =

it is a list of all test phases related to the


selected object; for each phase the
related phaseStatus is provided (Passed,
Failed, Running or Waiting).

phaseId =
phaseStatus =
...
...
testOutcome

It represents the test result: it can be


Inconclusive (if the phases already
executed were successful) or Fail (if at
least one of the executed phases failed).

testState = Testing

It can assume one of the following values:


not_initialized, idle, initializing, suspended, testing, terminating and disabled.

Application Guidelines:
None.
Example of Command Execution:
Gettest DILNA:NAME=RACK:0/DILNA:0;

LOCK DILNA
LOCK DILNA

NAME=RACK:0..7/DILNA:0..7;

Command Tree:
MANAGED-ELEMENT h BSS-EQUIPMENT h BTSEP h RACK h DILNA h
LOCK DILNA
Applicability:
Phase 2 and Phase 3.
Visibility level: 1.
Command Description:
This command changes the administrative state of DILNA (Low Noise Amplifier of Diversity Multicoupler).
Long Names:
NAME

Address of the managed object

System Responses:
Operation Completed

280

Id:0900d805805944bc

A50016-G5100-B333-04-7619

BS-4x / 82 II / 240 / 241 / 240XL commands

DILNA

The specified change of administrative state has been perfomed:


JOB: 100
PC Time&Date: 16:40:38 03/23/2005
NE Time&Date: 16:38:32 09/15/2004
USER NAME:

User_q

COMMAND:

Lock DILNA:NAME=RACK:0/DILNA:0;

SW RELEASE:

01-04-17-01-26-51_05-02-23

COMMAND RESULT: Operation successful


administrativeState = Locked
END OF OUTPUT FOR JOB 100

CHANGED STATE EVENT REPORT:


This provides information about the administrative state, the operational state and the
availability status every time a state change occurs:
JOB: 101
PC Time&Date: 16:40:38 03/23/2005
NE Time&Date: 16:38:32 09/15/2004
USER NAME:

User_q

SW RELEASE:

01-04-17-01-26-51_05-02-23

COMMAND RESULT: Operation successful


CHANGED STATE EVENT REPORT:
NAME = RACK:0/DILNA:0
Administrative State = LOCKED
Notification Identifier = 519
END OF OUTPUT FOR JOB 101
Operation Failed
The specified change of administrative state has not been performed.

A50016-G5100-B333-04-7619

Id:0900d805805944bc

281

DILNA

BS-4x / 82 II / 240 / 241 / 240XL commands

Application Guidelines:
While a Frequency Redefinition procedure is ongoing, the lock/unlock of all HMO's
actually related to a TRX is forbidden because that could lead to minor SELIC problem
or major SELIC problem alarms.
Example of Command Execution:
Lock DILNA:NAME=RACK:0/DILNA:0;

PERFTEST DILNA
PERFTEST DILNA

NAME=RACK:0..7/DILNA:0..7;

Command Tree:
MANAGED-ELEMENT h BSS-EQUIPMENT h BTSEP h RACK h DILNA h
PERFTEST DILNA
Applicability:
Phase 2 and Phase 3.
Visibility level: 1.
Command Description:
This command is used to start an asynchronous test in the object.
Long Names:
NAME

Address of the managed object

System Responses:
Operation Completed
Test configuration has been set and the specified test has been started. The System
response will not be addressed to the MOT but to the object BTSE.
JOB: 211
PC Time&Date: 12:13:39 03/23/2005
NE Time&Date: 13:15:13 09/15/2004
USER NAME:

User_q

COMMAND:

Perftest DILNA:NAME=RACK:0/DILNA:0;

SW RELEASE:

01-04-17-01-26-51_05-02-23

COMMAND RESULT: Operation successful


MOT = RACK:0/DILNA:0
tO = BTSETEST:1
END OF OUTPUT FOR JOB 211

282

Id:0900d805805944bc

A50016-G5100-B333-04-7619

BS-4x / 82 II / 240 / 241 / 240XL commands

DILNA

JOB: 212
PC Time&Date: 12:13:42 03/23/2005
NE Time&Date: 13:15:17 09/15/2004
USER NAME:

User_q

SW RELEASE:

01-04-17-01-26-51_05-02-23

COMMAND RESULT: Operation successful


ChangedConfigurationNotification:
name = BTSETEST:1
ChangeInfo = created
END OF OUTPUT FOR JOB 212
JOB: 213
PC Time&Date: 12:13:50 03/23/2005
NE Time&Date: 13:15:25 09/15/2004
USER NAME:

User_q

SW RELEASE:

01-04-17-01-26-51_05-02-23

COMMAND RESULT: Operation successful


CHANGED STATE EVENT REPORT:
NAME = RACK:0/DILNA:0
Operational State = ENABLED
Availability Status = NULL_value
Standby Status = Cold_Standby
Notification Identifier = 168
END OF OUTPUT FOR JOB 213

JOB: 214

A50016-G5100-B333-04-7619

Id:0900d805805944bc

283

DILNA

BS-4x / 82 II / 240 / 241 / 240XL commands

PC Time&Date: 12:13:50 03/23/2005


NE Time&Date: 13:15:25 09/15/2004
USER NAME:

User_q

SW RELEASE:

01-04-17-01-26-51_05-02-23

COMMAND RESULT: Operation successful


Test Report:
name = BTSETEST:1
testOutcome = PASSED
testTermination = Normal
MOT = RACK:0/DILNA:0
executedPhases =
PreliminaryTestsDilna
SerialEepromTestDilna
EndTestDilna
END OF OUTPUT FOR JOB 214
JOB: 215
PC Time&Date: 12:13:50 03/23/2005
NE Time&Date: 13:15:25 09/15/2004
USER NAME:

User_q

SW RELEASE:

01-04-17-01-26-51_05-02-23

COMMAND RESULT: Operation successful


ChangedConfigurationNotification:
name = BTSETEST:1
ChangeInfo = deleted
END OF OUTPUT FOR JOB 215
The test results will be displayed at the end of the test phases.
Result TEST:
name =

284

TEST:<n>

Id:0900d805805944bc

A50016-G5100-B333-04-7619

BS-4x / 82 II / 240 / 241 / 240XL commands

DILNA

testOutcome =

This field represents the test result; one of the following values can be displayed:
Pass

all the test phases are successfully


performed.

Inconclusive

the test is aborted by the system or


the test is terminated by the operator.

Fail

if at least one of the executed phases


fail.

mOts =

It is the identifier of the hardware object under test.

testTermination =

It specifies how the test is terminated, it can assume


the following values:
Normal

all the test phases are performed.

Abort

the test is aborted by system.

Cancel

the test is terminated by operator.

executedPhases
phaseId =
additionalWords =
....

It represents the list of the executed test phases (in


case of successful test result, all the test phases will
be listed).

failedPhases
phaseId =

It represents the list of the failed test phase; additional information is provided for each phase.

phaseId =
....
skippedPhases
phaseId =

It represents the list of the skipped phases; they are


displayed only for test stopped during it execution.

phaseId =
....
poprosedRepair Action
=

A list of most probable fail probable causes is shown


(max four messages)

Operation Failed
This NACK-message occurs in the following cases: Message cannot be performed, test
not supported, capacity restrictions, physical configuration cannot be performed, object
not locked.
Application Guidelines:

In phase 3 MO must be locked previous to the command execution

Example of Command Execution:


Perftest DILNA:NAME=RACK:0/DILNA:0;

A50016-G5100-B333-04-7619

Id:0900d805805944bc

285

DILNA

BS-4x / 82 II / 240 / 241 / 240XL commands

SET DILNA
SET DILNA

NAME=RACK:0..7/DILNA:0..7 [,SCELLNO=] [,WDLNA=];

Command Tree:
MANAGED-ELEMENT h BSS-EQUIPMENT h BTSEP h RACK h DILNA h
SET DILNA
Applicability:
Phase 2 and Phase 3.
Visibility level: 2.
Command Description:
This command sets the attributes of the DILNA (Low Noise Amplifier of Diversity Multicoupler) to the BTSE data base.
Long Names:
NAME

Address of the managed object

SCELLNO

secondCellNumber

WDLNA

wiringDataLna

System Responses:
Operation Completed
After command execution, a message of Changed Attribute Event Report is displayed.
A further message indicates the result of the operation. An example of set command is
the following:
JOB: 62
PC Time&Date: 11:57:39 03/23/2005
NE Time&Date: 12:59:14 09/15/2004
USER NAME:

User_q

COMMAND:

Set DILNA:NAME=RACK:0/DILNA:0;

SW RELEASE:

01-04-17-01-26-51_05-02-23

COMMAND RESULT: Operation successful


END OF OUTPUT FOR JOB 62
Operation Failed
The specified attributes have not been set. In addition to the general NACK causes, a
specific NACK cause, which indicates that the command is inconsistent with the
physical configuration, is possible.
Application Guidelines:

286

The DIAMCO_LNA and the CUs are in the same rack and belong to the same cell

Id:0900d805805944bc

A50016-G5100-B333-04-7619

BS-4x / 82 II / 240 / 241 / 240XL commands

DILNA

Each CU has a 'normal path' RX input and a 'diversity path' RX input and the
operator must indicate which of them is wired to the DIAMCO_LNA.

Wildcard addressing is not possible.

All CUs which are listed in a previous GET DILNA for WDLNA have to be locked
(LOCK CU command) before one of these CUs can be removed from WDLNA.
Before locking these CUs first a shutdown of the TRXs related to these CUs should
be done.

Example of Command Execution:


Set DILNA:NAME=RACK:0/DILNA:0,SCELLNO=2,WDLNA=CU0D&CU1D&
CU2D&CU3D;

STOPTEST DILNA
STOPTEST DILNA

NAME=RACK:0..7/DILNA:0..7;

Command Tree:
MANAGED-ELEMENT h BSS-EQUIPMENT h BTSEP h RACK h DILNA h
STOPTEST DILNA
Applicability:
Phase 2 and Phase 3.
Visibility level: 1.
Command Description:
This command is used to stop a diagnostic previously started.
Long Names:
NAME

Address of the managed object

System Responses:
Operation Completed
Test has been stopped. The System Responses will not be addressed to the MOT but
to the object BTSEP.

Result TEST:
name =

TEST:<n>

testOutcome =

inconclusive

mOts =

It is the identifier of the hardware object under test.

testTermination =

Cancel

executedPhases
phaseId =
...
.

A50016-G5100-B333-04-7619

It represents the list of the executed test phases; the


list is not shown for test in the waiting list (queued).

Id:0900d805805944bc

287

DILNA

BS-4x / 82 II / 240 / 241 / 240XL commands

failedPhases
phaseId =

It represents the list of the failed test phase;

phaseId =

additional information is provided for each phase.

....
skippedPhases
phaseId =
phaseId =

It represents the list of the skipped phases;the list is


not shown for test in the waiting list (queued).

Operation Failed
Test has not been stopped. This NACK-message can occur when the specified test is
not running or in case of test which cannot be stopped.
Application Guidelines:
None.
Example of Command Execution:
Stoptest DILNA:NAME=RACK:0/DILNA:0;

UNLOCK DILNA
UNLOCK DILNA

NAME=RACK:0..7/DILNA:0..7;

Command Tree:
MANAGED-ELEMENT h BSS-EQUIPMENT h BTSEP h RACK h DILNA h
UNLOCK DILNA
Applicability:
Phase 2 and Phase 3.
Visibility level: 1.
Command Description:
This command changes the administrative state of the DILNA (Low Noise Amplifier of
Diversity Multicoupler).
Long Names:
NAME

Address of the managed object

System Responses:
Operation Completed
The specified change of administrative state has been perfomed:
JOB: 102
PC Time&Date: 16:40:43 03/23/2005
NE Time&Date: 16:38:37 09/15/2004

288

Id:0900d805805944bc

A50016-G5100-B333-04-7619

BS-4x / 82 II / 240 / 241 / 240XL commands

DILNA

USER NAME:

User_q

COMMAND:

Unlock DILNA:NAME=RACK:0/DILNA:0;

SW RELEASE:

01-04-17-01-26-51_05-02-23

COMMAND RESULT: Operation successful


administrativeState = Unlocked
END OF OUTPUT FOR JOB 102

CHANGED STATE EVENT REPORT:


This provides information about the administrative state, the operational state and the
availability status every time a state change occurs:
JOB: 103
PC Time&Date: 16:40:43 03/23/2005
NE Time&Date: 16:38:37 09/15/2004
USER NAME:

User_q

SW RELEASE:

01-04-17-01-26-51_05-02-23

COMMAND RESULT: Operation successful


CHANGED STATE EVENT REPORT:
NAME = RACK:0/DILNA:0
Administrative State = UNLOCKED
Notification Identifier = 521
END OF OUTPUT FOR JOB 103
Operation Failed
The specified change of administrative state has not been performed.
Application Guidelines:
While a Frequency Redefinition procedure is ongoing, the lock/unlock of all HMO's
actually related to a TRX is forbidden because that could lead to minor SELIC problem
or major SELIC problem alarms.
Example of Command Execution:
Unlock DILNA:NAME=RACK:0/DILNA:0;

A50016-G5100-B333-04-7619

Id:0900d805805944bc

289

DUAMCO

BS-4x / 82 II / 240 / 241 / 240XL commands

DUAMCO
DUAMCO object is mainly used to represent the status of the firmware download; the
state changes of the DUAMCO object are triggered by subsystems RC, AE and DG as
usual.
DUAMCO object is automatically created if an MFDUAMCO is successfully registered.

DELETE DUAMCO
DELETE DUAMCO

NAME=RACK:0..7/DUAMCO:0..5;

Command Tree:
MANAGED-ELEMENT h BSS-EQUIPMENT h BTSEP h RACK h DUAMCO h
DELETE DUAMCO
Applicability:
Phase 2 and Phase 3.
Visibility level: 2.
Command Description:
This command deletes the DUAMCO from the BTSE data base.
Automatic deletion is also possible.

Long Names:
NAME

Address of the managed object

System Responses:
Operation Completed
After command execution, a message of Changed Configuration Notification is displayed. A further message indicates the result of the operation. An example of delete
command is the following:
JOB: 71
PC Time&Date: 05.05.2008 11:35:33 +02:00
NE Time&Date: 01.01.1990 00:12:10 +00:00
USER NAME:

User_r

COMMAND:

Delete DUAMCO:NAME=RACK:0/DUAMCO:0;

SW RELEASE:

01-04-19-01-86-MF_08-04-24

COMMAND RESULT: Operation successful

290

Id:0900d805805944be

A50016-G5100-B333-04-7619

BS-4x / 82 II / 240 / 241 / 240XL commands

DUAMCO

END OF OUTPUT FOR JOB 71

Operation Failed
None.
Application Guidelines:
Automatic deletion is not possible in case of a BCOM/FCOM is inserted in ACOM slot.
Example of Command Execution:
DELETE DUAMCO:
NAME=RACK:0/ DUAMCO:0;

GET DUAMCO
GET DUAMCO

NAME=RACK:0..7/DUAMCO:0..5 [,REQATTL=ALS, AST,


AVS, OST, PRS, DMCFWID, RELFUNCOBJ];

Command Tree:
MANAGED-ELEMENT h BSS-EQUIPMENT h BTSEP h RACK h DUAMCO h
GET DUAMCO
Applicability:
Phase 2 and Phase 3.
Visibility level: 0.
Command Description:
This command displays the attributes of the DUAMCO.
Long Names:
NAME

Address of the managed object

REQATTL

Required attribute list

ALS

alarmStatus

AST

administrativeState

AVS

availabilityStatus

OST

operationalState

PRS

proceduralStatus

DMCFWID

duamcoFwId

RELFUNCOBJ

relatedFuncObjects

System Responses:
Operation Completed
A message indicates the result of the operation. An example of get command is the following:

A50016-G5100-B333-04-7619

Id:0900d805805944be

291

DUAMCO

BS-4x / 82 II / 240 / 241 / 240XL commands

JOB: 86
PC Time&Date: 05.05.2008 11:35:48 +02:00
NE Time&Date: 01.01.1990 00:12:25 +00:00
USER NAME:

User_r

COMMAND:

Get DUAMCO:NAME=RACK:0/DUAMCO:0;

SW RELEASE:

01-04-19-01-86-MF_08-04-24

COMMAND RESULT: Operation successful

alarmStatus = CLEARED
administrativeState = Unlocked
availabilityStatus = NULL
operationalState = ENABLED
proceduralStatus = NULL
duamcoFwId = "BFDU0250.SWI:00-50-19-02-15-00_08-01-01"
relatedFuncObjects = Null
END OF OUTPUT FOR JOB 86
Operation Failed
None.
Application Guidelines:
None.
Example of Command Execution:
Get
DUAMCO:NAME=RACK:0/DUAMCO:0,REQATTL=ALS&AST&AVS&OST&PRS&DM
CFWID&RELFUNCOBJ;

GETTEST DUAMCO
GETTEST DUAMCO

NAME=RACK:0..7/DUAMCO:0..5;

Command Tree:
MANAGED-ELEMENT h BSS-EQUIPMENT h BTSEP h RACK h DUAMCO h
GETTEST DUAMCO
Applicability:
Phase 2 and Phase 3.
Visibility level: 0.

292

Id:0900d805805944be

A50016-G5100-B333-04-7619

BS-4x / 82 II / 240 / 241 / 240XL commands

DUAMCO

Command Description:
This command displays the attributes of the object test.
Long Names:
NAME

Address of the managed object

REQATTL

Required attribute list

System Responses:
Operation Completed
None.
Operation Failed
None.
Application Guidelines:
None.
Example of Command Execution:
Gettest DUAMCO:NAME=RACK:0/DUAMCO:0,REQATTL=MORT&TESTMON&TESTOUT&TESTST;

LOCK DUAMCO
LOCK DUAMCO

NAME=RACK:0..7/DUAMCO:0..5;

Command Tree:
MANAGED-ELEMENT h BSS-EQUIPMENT h BTSEP h RACK h DUAMCO h
LOCK DUAMCO
Applicability:
Phase 2 and Phase 3.
Visibility level: 1.
Command Description:
This command changes the administrative state of DUAMCO.
Long Names:
NAME

Address of the managed object

System Responses:
Operation Completed
After command execution, a message of Changed Configuration Notification is displayed. A further message indicates the result of the operation. An example of lock
command is the following:
JOB: 99
PC Time&Date: 05.05.2008 11:36:17 +02:00

A50016-G5100-B333-04-7619

Id:0900d805805944be

293

DUAMCO

BS-4x / 82 II / 240 / 241 / 240XL commands

NE Time&Date: 01.01.1990 00:12:54 +00:00


USER NAME:

User_r

COMMAND:

Lock DUAMCO:NAME=RACK:0/DUAMCO:0;

SW RELEASE:

01-04-19-01-86-MF_08-04-24

COMMAND RESULT: Operation successful

administrativeState = Locked
END OF OUTPUT FOR JOB 99
Operation Failed
None.
Application Guidelines:
None.
Example of Command Execution:
Lock DUAMCO:NAME=RACK:0/DUAMCO:0, AST=Locked;

PERFTEST DUAMCO
PERFTEST DUAMCO

NAME=RACK:0..7/DUAMCO:0..5;

Command Tree:
MANAGED-ELEMENT h BSS-EQUIPMENT h BTSEP h RACK h DUAMCO h
PERFTEST DUAMCO
Applicability:
Phase 2 and Phase 3.
Visibility level: 1.
Command Description:
This command is used to start an asynchronous test in the object.
Long Names:
NAME

Address of the managed object

System Responses:
Operation Completed
After command execution, a message of Changed Configuration Notification is displayed. A further message indicates the result of the operation. An example of perftest
command is the following:
JOB: 138

294

Id:0900d805805944be

A50016-G5100-B333-04-7619

BS-4x / 82 II / 240 / 241 / 240XL commands

DUAMCO

PC Time&Date: 05.05.2008 11:36:42 +02:00


NE Time&Date: 01.01.1990 00:13:19 +00:00
USER NAME:

User_r

COMMAND:

Perftest DUAMCO:NAME=RACK:0/DUAMCO:0;

SW RELEASE:

01-04-19-01-86-MF_08-04-24

COMMAND RESULT: Operation successful

MOT = RACK:0/DUAMCO:0
tO = BTSETEST:1
END OF OUTPUT FOR JOB 138
Operation Failed
None.
Application Guidelines:
None.
Example of Command Execution:
Perftest DUAMCO:NAME=RACK:0/DUAMCO:0;

STOPTEST DUAMCO
STOPTEST DUAMCO

NAME=RACK:0..7/DUAMCO:0..5;

Command Tree:
MANAGED-ELEMENT h BSS-EQUIPMENT h BTSEP h RACK h DUAMCO h
STOPTEST DUAMCO
Applicability:
Phase 2 and Phase 3.
Visibility level: 1.
Command Description:
This command is used to stop a diagnostic previously started.
Long Names:
NAME

Address of the managed object

System Responses:
Operation Completed
None.
Operation Failed
None.

A50016-G5100-B333-04-7619

Id:0900d805805944be

295

DUAMCO

BS-4x / 82 II / 240 / 241 / 240XL commands

Application Guidelines:
None.
Example of Command Execution:
Stoptest DUAMCO:NAME=RACK:0/DUAMCO:0;

UNLOCK DUAMCO
UNLOCK DUAMCO

NAME=RACK:0..7/DUAMCO:0..5;

Command Tree:
MANAGED-ELEMENT h BSS-EQUIPMENT h BTSEP h RACK h DUAMCO h
UNLOCK DUAMCO
Applicability:
Phase 2 and Phase 3.
Visibility level: 1.
Command Description:
This command changes the administrative state of DUAMCO.
Long Names:
NAME

Address of the managed object

System Responses:
Operation Completed
After command execution, a message of Changed Configuration Notification is displayed. A further message indicates the result of the operation. An example of unlock
command is the following:
JOB: 108
PC Time&Date: 05.05.2008 11:36:35 +02:00
NE Time&Date: 01.01.1990 00:13:12 +00:00
USER NAME:

User_r

COMMAND:

Unlock DUAMCO:NAME=RACK:0/DUAMCO:0;

SW RELEASE:

01-04-19-01-86-MF_08-04-24

COMMAND RESULT: Operation successful

administrativeState = Unlocked
Operation Failed
None.

296

Id:0900d805805944be

A50016-G5100-B333-04-7619

BS-4x / 82 II / 240 / 241 / 240XL commands

DUAMCO

Application Guidelines:
None.
Example of Command Execution:
Unlock DUAMCO:NAME=RACK:0/DUAMCO:0, AST=Unlocked;

A50016-G5100-B333-04-7619

Id:0900d805805944be

297

DUDCTMA

BS-4x / 82 II / 240 / 241 / 240XL commands

DUDCTMA
The DUDCTMA object represents the power supply module of a TMA (Tower Mounted
Amplifier) connected to DUAMCO.

CREATE DUDCTMA
CREATE DUDCTMA

NAME=RACK:0..7/DUDCTMA:0..11;

Command Tree:
MANAGED-ELEMENT h BSS-EQUIPMENT h BTSEP h RACK h DUDCTMA
h CREATE DUDCTMA
Applicability:
Phase 2 and Phase 3.
Visibility level: 2.
Command Description:
This command adds the DUAMCO_DC_TMA (DC Power Supply Module of TMA) to the
BTSE data base.
Long Names:
NAME

Address of the managed object

System Responses:
Operation Completed
After command execution, a message of Changed Configuration Notification is displayed.
A further message indicates the result of the operation. An example of create command
is the following:
JOB: 78
PC Time&Date: 16:38:29 03/23/2005
NE Time&Date: 16:36:23 09/15/2004
USER NAME:

User_s

SW RELEASE:

01-04-17-01-26-51_05-02-23

COMMAND RESULT: Operation successful


ChangedConfigurationNotification:
name = RACK:0/DUDCTMA:0
ChangeInfo = created

298

Id:0900d805805944c0

A50016-G5100-B333-04-7619

BS-4x / 82 II / 240 / 241 / 240XL commands

DUDCTMA

END OF OUTPUT FOR JOB 78


JOB: 79
PC Time&Date: 16:38:29 03/23/2005
NE Time&Date: 16:36:23 09/15/2004
USER NAME:

User_s

COMMAND:

Create DUDCTMA:NAME=RACK:0/DUDCTMA:0;

SW RELEASE:

01-04-17-01-26-51_05-02-23

COMMAND RESULT: Operation successful


END OF OUTPUT FOR JOB 79
Operation Failed
The specified Object has not been created. In addition to the general NACK causes, a
specific NACK cause, which indicates that the command is inconsistent with the
physical configuration, is possible. An example is the following:
JOB: 75
PC Time&Date: 16:37:54 03/23/2005
NE Time&Date: 16:35:47 09/15/2004
USER NAME:

User_s

COMMAND:

Create DUDCTMA:NAME=RACK:0/DUDCTMA:0;

SW RELEASE:

01-04-17-01-26-51_05-02-23

COMMAND RESULT: OPERATION FAILED


Message cannot be performed (-17)
END OF OUTPUT FOR JOB 75
Application Guidelines:
The commands for the objects DUDCTMA:2n and DUDCTMA:2n+1 are not allowed if
the object DUAMCO:n exists and is in the state OST.AVS = enabled.degraded (firmware download is active).
Example of Command Execution:
Create DUDCTMA:NAME=RACK:0/DUDCTMA:0;

A50016-G5100-B333-04-7619

Id:0900d805805944c0

299

DUDCTMA

BS-4x / 82 II / 240 / 241 / 240XL commands

DELETE DUDCTMA
DELETE DUDCTMA

NAME=RACK:0..7/DUDCTMA:0..11;

Command Tree:
MANAGED-ELEMENT h BSS-EQUIPMENT h BTSEP h RACK h DUDCTMA
h DELETE DUDCTMA
Applicability:
Phase 2 and Phase 3.
Visibility level: 2.
Command Description:
This command deletes the DUAMCO_DC_TMA (DC Power Supply Module of TMA)
from the BTSE data base.
Long Names:
NAME

Address of the managed object

System Responses:
Operation Completed
After command execution, a message of Changed Configuration Notification is displayed. A further message indicates the result of the operation. An example of delete
command is the following:
JOB: 90
PC Time&Date: 16:39:22 03/23/2005
NE Time&Date: 16:37:16 09/15/2004
USER NAME:

User_s

SW RELEASE:

01-04-17-01-26-51_05-02-23

COMMAND RESULT: Operation successful


ChangedConfigurationNotification:
name = RACK:0/DUDCTMA:0
ChangeInfo = deleted
END OF OUTPUT FOR JOB 90
JOB: 91
PC Time&Date: 16:39:22 03/23/2005

300

Id:0900d805805944c0

A50016-G5100-B333-04-7619

BS-4x / 82 II / 240 / 241 / 240XL commands

DUDCTMA

NE Time&Date: 16:37:16 09/15/2004


USER NAME:

User_s

COMMAND:

Delete DUDCTMA:NAME=RACK:0/DUDCTMA:0;

SW RELEASE:

01-04-17-01-26-51_05-02-23

COMMAND RESULT: Operation successful


END OF OUTPUT FOR JOB 91
Operation Failed
The specified Object has not been deleted. Additionally to the general NACK causes, a
specific NACK cause, meaning that the command is inconsistent with physical configuration, is possible.
Application Guidelines:

DUDCTMA must be locked in phase 3 before deletion

The commands for the objects DUDCTMA:2n and DUDCTMA:2n+1 are not allowed
if the object DUAMCO:n exists and is in the state OST.AVS = enabled.degraded
(firmware download is active)

Example of Command Execution:


Delete DUDCTMA:NAME=RACK:0/DUDCTMA:0;

GET DUDCTMA
GET DUDCTMA

NAME=RACK:0..7/DUDCTMA:0..11 [,REQATTL=ALS,
AST, AVS, OST, PRS, RELFUNCOBJ];

Command Tree:
MANAGED-ELEMENT h BSS-EQUIPMENT h BTSEP h RACK h DUDCTMA
h GET DUDCTMA
Applicability:
Phase 2 and Phase 3.
Visibility level: 0.
Command Description:
This command displays the attributes of the DUAMCO_DC_TMA (DC Power Supply
Module of TMA).
Long Names:
NAME

Address of the managed object

REQATTL

Required attribute list

ALS

alarmStatus

AST

administrativeState

AVS

availabilityStatus

OST

operationalState

A50016-G5100-B333-04-7619

Id:0900d805805944c0

301

DUDCTMA

BS-4x / 82 II / 240 / 241 / 240XL commands

PRS

proceduralStatus

RELFUNCOBJ

relatedFuncObjects

System Responses:
Operation Completed
A message indicates the result of the operation. An example of get command is the following:
JOB: 82
PC Time&Date: 16:38:53 03/23/2005
NE Time&Date: 16:36:47 09/15/2004
USER NAME:

User_s

COMMAND:

Get DUDCTMA:NAME=RACK:0/DUDCTMA:0;

SW RELEASE:

01-04-17-01-26-51_05-02-23

COMMAND RESULT: Operation successful


alarmStatus = CLEARED
administrativeState = Unlocked
availabilityStatus = NULL
operationalState = ENABLED
proceduralStatus = NULL
relatedFuncObjects =
END OF OUTPUT FOR JOB 82
Operation Failed
The GET command has not been successfully executed. A general NACK will indicate
possible errors or a specific NACK strictly related to the single command is possible.
Application Guidelines:
None.
Example of Command Execution:
Get DUDCTMA:NAME=RACK:0/DUDCTMA:0,REQATTL=ALS&AST&AVS&
OST&PRS&RELFUNCOBJ;

GETTEST DUDCTMA
GETTEST DUDCTMA

302

NAME=RACK:0..7/DUDCTMA:0..11;

Id:0900d805805944c0

A50016-G5100-B333-04-7619

BS-4x / 82 II / 240 / 241 / 240XL commands

DUDCTMA

Command Tree:
MANAGED-ELEMENT h BSS-EQUIPMENT h BTSEP h RACK h DUDCTMA
h GETTEST DUDCTMA
Applicability:
Phase 2 and Phase 3.
Visibility level: 0.
Command Description:
This command displays the attributes of the object test.
Long Names:
NAME

Address of the managed object

REQATTL

Required attribute list

System Responses:
Operation Completed
A message indicates the result of the operation. An example of gettest command is the
following:
JOB: 216
PC Time&Date: 12:13:57 03/23/2005
NE Time&Date: 13:15:32 09/15/2004
USER NAME:

User_s

COMMAND:

Gettest DUDCTMA:NAME=RACK:0/DUDCTMA:0;

SW RELEASE:

01-04-17-01-26-51_05-02-23

COMMAND RESULT: Operation successful


MOT = RACK:0/DUDCTMA:0
testMonitor =
phaseId = PreliminaryTestsDudctma
phaseStatus = Running
phaseId = CheckAlarmStatusDudctma
phaseStatus = Waiting
phaseId = EndTestDudctma
phaseStatus = Waiting
testOutcome = INCONCLUSIVE
testState = INITIALIZING
END OF OUTPUT FOR JOB 216

A50016-G5100-B333-04-7619

Id:0900d805805944c0

303

DUDCTMA

BS-4x / 82 II / 240 / 241 / 240XL commands

Operation Failed
The GET command has not been successfully executed. A general NACK will indicate
possible errors or a specific NACK strictly related to the single command is possible.
testMonitor
phaseId =
phaseStatus =

it is a list of all test phases related to the


selected object; for each phase the
related phaseStatus is provided (Passed,
Failed, Running or Waiting).

phaseId =
phaseStatus =
...
...
testOutcome

It represents the test result: it can be


Inconclusive (if the phases already
executed were successful) or Fail (if at
least one of the executed phases failed).

testState = Testing

It can assume one of the following values:


not_initialized, idle, initializing, suspended, testing, terminating and disabled.

Application Guidelines:
None.
Example of Command Execution:
Gettest DUDCTMA:NAME=RACK:0/DUDCTMA:0;

LOCK DUDCTMA
LOCK DUDCTMA

NAME=RACK:0..7/DUDCTMA:0..11;

Command Tree:
MANAGED-ELEMENT h BSS-EQUIPMENT h BTSEP h RACK h DUDCTMA
h LOCK DUDCTMA
Applicability:
Phase 2 and Phase 3.
Visibility level: 1.
Command Description:
This command changes the administrative state of DUAMCO_DC_TMA (DC Power
Supply Module of TMA).
Long Names:
NAME

Address of the managed object

System Responses:
Operation Completed

304

Id:0900d805805944c0

A50016-G5100-B333-04-7619

BS-4x / 82 II / 240 / 241 / 240XL commands

DUDCTMA

The specified change of administrative state has been perfomed:


JOB: 83
PC Time&Date: 16:38:58 03/23/2005
NE Time&Date: 16:36:52 09/15/2004
USER NAME:

User_s

COMMAND:

Lock DUDCTMA:NAME=RACK:0/DUDCTMA:0;

SW RELEASE:

01-04-17-01-26-51_05-02-23

COMMAND RESULT: Operation successful


administrativeState = Locked
END OF OUTPUT FOR JOB 83

CHANGED STATE EVENT REPORT:


This provides information about the administrative state, the operational state and the
availability status every time a state change occurs:
JOB: 84
PC Time&Date: 16:38:58 03/23/2005
NE Time&Date: 16:36:52 09/15/2004
USER NAME:

User_s

SW RELEASE:

01-04-17-01-26-51_05-02-23

COMMAND RESULT: Operation successful


CHANGED STATE EVENT REPORT:
NAME = RACK:0/DUDCTMA:0
Administrative State = LOCKED
Notification Identifier = 511
END OF OUTPUT FOR JOB 84
Operation Failed
The specified change of administrative state has not been performed.

A50016-G5100-B333-04-7619

Id:0900d805805944c0

305

DUDCTMA

BS-4x / 82 II / 240 / 241 / 240XL commands

Application Guidelines:
The commands for the objects DUDCTMA:2n and DUDCTMA:2n+1 are not allowed if
the object DUAMCO:n exists and is in the state OST.AVS = enabled.degraded (firmware download is active).
While a Frequency Redefinition procedure is ongoing, the lock/unlock of all HMO's
actually related to a TRX is forbidden because that could lead to minor SELIC problem
or major SELIC problem alarms.
Example of Command Execution:
Lock DUDCTMA:NAME=RACK:0/DUDCTMA:0;

PERFTEST DUDCTMA
PERFTEST DUDCTMA NAME=RACK:0..7/DUDCTMA:0..11;
Command Tree:
MANAGED-ELEMENT h BSS-EQUIPMENT h BTSEP h RACK h DUDCTMA
h PERFTEST DUDCTMA
Applicability:
Phase 2 and Phase 3.
Visibility level: 1.
Command Description:
This command is used to start an asynchronous test in the object.
Long Names:
NAME

Address of the managed object

System Responses:
Operation Completed
Test configuration has been set and the specified test has been started. The System
response will not be addressed to the MOT but to the object BTSEP.
JOB: 216
PC Time&Date: 12:13:57 03/23/2005
NE Time&Date: 13:15:32 09/15/2004
USER NAME:

User_s

COMMAND:

Perftest DUDCTMA:NAME=RACK:0/DUDCTMA:0;

SW RELEASE:

01-04-17-01-26-51_05-02-23

COMMAND RESULT: Operation successful


MOT = RACK:0/DUDCTMA:0
tO = BTSETEST:2

306

Id:0900d805805944c0

A50016-G5100-B333-04-7619

BS-4x / 82 II / 240 / 241 / 240XL commands

DUDCTMA

END OF OUTPUT FOR JOB 216


JOB: 217
PC Time&Date: 12:13:58 03/23/2005
NE Time&Date: 13:15:33 09/15/2004
USER NAME:

User_s

SW RELEASE:

01-04-17-01-26-51_05-02-23

COMMAND RESULT: Operation successful


ChangedConfigurationNotification:
name = BTSETEST:2
ChangeInfo = created
END OF OUTPUT FOR JOB 217
JOB: 218
PC Time&Date: 12:13:58 03/23/2005
NE Time&Date: 13:15:33 09/15/2004
USER NAME:

User_s

SW RELEASE:

01-04-17-01-26-51_05-02-23

COMMAND RESULT: Operation successful


CHANGED STATE EVENT REPORT:
NAME = RACK:0/DUDCTMA:0
Operational State = ENABLED
Availability Status = NULL_value
Standby Status = Cold_Standby
Notification Identifier = 256
END OF OUTPUT FOR JOB 218
JOB: 219

A50016-G5100-B333-04-7619

Id:0900d805805944c0

307

DUDCTMA

BS-4x / 82 II / 240 / 241 / 240XL commands

PC Time&Date: 12:13:58 03/23/2005


NE Time&Date: 13:15:33 09/15/2004
USER NAME:

User_s

SW RELEASE:

01-04-17-01-26-51_05-02-23

COMMAND RESULT: Operation successful


Test Report:
name = BTSETEST:2
testOutcome = PASSED
testTermination = Normal
MOT = RACK:0/DUDCTMA:0
executedPhases =
PreliminaryTestsDudctma
BootEepromTestDudctma
SerialEepromTestDudctma
EndTestDudctma
END OF OUTPUT FOR JOB 219
JOB: 220
PC Time&Date: 12:13:58 03/23/2005
NE Time&Date: 13:15:33 09/15/2004
USER NAME:

User_s

SW RELEASE:

01-04-17-01-26-51_05-02-23

COMMAND RESULT: Operation successful


ChangedConfigurationNotification:
name = BTSETEST:2
ChangeInfo = deleted
END OF OUTPUT FOR JOB 220
The test results will be displayed at the end of the test phases.

308

Id:0900d805805944c0

A50016-G5100-B333-04-7619

BS-4x / 82 II / 240 / 241 / 240XL commands

DUDCTMA

Result TEST:
name =

TEST:<n>

testOutcome =

This field represents the test result; one of the following values can be displayed:
Pass

all the test phases are successfully


performed.

Inconclusive

the test is aborted by the system or


the test is terminated by the operator.

Fail

if at least one of the executed phases


fail.

mOts =

It is the identifier of the hardware object under test.

testTermination =

It specifies how the test is terminated, it can assume


the following values:
Normal

all the test phases are performed.

Abort

the test is aborted by system.

Cancel

the test is terminated by operator.

executedPhases
phaseId =
additionalWords =
....

It represents the list of the executed test phases (in


case of successful test result, all the test phases will
be listed).

failedPhases
phaseId =

It represents the list of the failed test phase; additional information is provided for each phase.

phaseId =
....
skippedPhases
phaseId =

It represents the list of the skipped phases; they are


displayed only for test stopped during it execution.

phaseId =
....
poprosedRepair Action
=

A list of most probable fail probable causes is shown


(max four messages)

Operation Failed
This NACK-message occurs in the following cases: Message cannot be performed, test
not supported, capacity restrictions, physical configuration cannot be performed, object
not locked.
Application Guidelines:

In phase 3 MO must be locked previous to the command execution

A50016-G5100-B333-04-7619

Id:0900d805805944c0

309

DUDCTMA

BS-4x / 82 II / 240 / 241 / 240XL commands

Example of Command Execution:


Perftest DUDCTMA:NAME=RACK:0/DUDCTMA:0;

STOPTEST DUDCTMA
STOPTEST DUDCTMA NAME=RACK:0..7/DUDCTMA:0..11;
Command Tree:
MANAGED-ELEMENT h BSS-EQUIPMENT h BTSEP h RACK h DUDCTMA
h STOPTEST DUDCTMA
Applicability:
Phase 2 and Phase 3.
Visibility level: 1.
Command Description:
This command is used to stop a diagnostic previously started.
Long Names:
NAME

Address of the managed object

System Responses:
Operation Completed
Test has been stopped. The System Responses will not be addressed to the MOT but
to the object BTSEP.

Result TEST:
name =

TEST:<n>

testOutcome =

inconclusive

mOts =

It is the identifier of the hardware object under test.

testTermination =

Cancel

executedPhases
phaseId =
...
.

It represents the list of the executed test phases; the


list is not shown for test in the waiting list (queued).

failedPhases
phaseId =

It represents the list of the failed test phase;

phaseId =

additional information is provided for each phase.

....
skippedPhases
phaseId =
phaseId =

310

It represents the list of the skipped phases;the list is


not shown for test in the waiting list (queued).

Id:0900d805805944c0

A50016-G5100-B333-04-7619

BS-4x / 82 II / 240 / 241 / 240XL commands

DUDCTMA

Operation Failed
Test has not been stopped. This NACK-message can occur when the specified test is
not running or in case of test which cannot be stopped.
Application Guidelines:
None.
Example of Command Execution:
Stoptest DUDCTMA:NAME=RACK:0/DUDCTMA:0;

UNLOCK DUDCTMA
UNLOCK DUDCTMA

NAME=RACK:0..7/DUDCTMA:0..11;

Command Tree:
MANAGED-ELEMENT h BSS-EQUIPMENT h BTSEP h RACK h DUDCTMA
h UNLOCK DUDCTMA
Applicability:
Phase 2 and Phase 3.
Visibility level: 1.
Command Description:
This command changes the administrative state of DUAMCO_DC_TMA (DC Power
Supply Module of TMA).
Long Names:
NAME

Address of the managed object

System Responses:
Operation Completed
The specified change of administrative state has been perfomed:
JOB: 85
PC Time&Date: 16:39:03 03/23/2005
NE Time&Date: 16:36:57 09/15/2004
USER NAME:

User_s

COMMAND:

Unlock DUDCTMA:NAME=RACK:0/DUDCTMA:0;

SW RELEASE:

01-04-17-01-26-51_05-02-23

COMMAND RESULT: Operation successful


administrativeState = Unlocked
END OF OUTPUT FOR JOB 85

A50016-G5100-B333-04-7619

Id:0900d805805944c0

311

DUDCTMA

BS-4x / 82 II / 240 / 241 / 240XL commands

CHANGED STATE EVENT REPORT:


This provides information about the administrative state, the operational state and the
availability status every time a state change occurs:
JOB: 86
PC Time&Date: 16:39:03 03/23/2005
NE Time&Date: 16:36:57 09/15/2004
USER NAME:

User_s

SW RELEASE:

01-04-17-01-26-51_05-02-23

COMMAND RESULT: Operation successful


CHANGED STATE EVENT REPORT:
NAME = RACK:0/DUDCTMA:0
Administrative State = UNLOCKED
Notification Identifier = 512
END OF OUTPUT FOR JOB 86
Operation Failed
The specified change of administrative state has not been performed.
Application Guidelines:
The commands for the objects DUDCTMA:2n and DUDCTMA:2n+1 are not allowed if
the object DUAMCO:n exists and is in the state OST.AVS = enabled.degraded (firmware download is active).
While a Frequency Redefinition procedure is ongoing, the lock/unlock of all HMO's
actually related to a TRX is forbidden because that could lead to minor SELIC problem
or major SELIC problem alarms.
Example of Command Execution:
Unlock DUDCTMA:NAME=RACK:0/DUDCTMA:0;

312

Id:0900d805805944c0

A50016-G5100-B333-04-7619

BS-4x / 82 II / 240 / 241 / 240XL commands

DULNA

DULNA
The DULNA object represents the low noise amplifier of DUAMCO (Dual Antenna Multicoupler) or FDUAMCO.

CREATE DULNA
CREATE DULNA

NAME=RACK:0..7/DULNA:0..11 ,CELLNO= ,COMBMD=


[,LNAMDB=] [,LNAPRED=] [,SCELLNO=] ,WDLNA=
[,GNADB=];

Command Tree:
MANAGED-ELEMENT h BSS-EQUIPMENT h BTSEP h RACK h DULNA h
CREATE DULNA
Applicability:
Phase 2 and Phase 3.
Visibility level: 2.
Command Description:
This command adds the DULNA (Low Noise Amplifier of Duplex Antenna Multicoupler)
together with its attributes to the BTSE data base.
Long Names:
NAME

Address of the managed object

CELLNO

cellNumber

COMBMD

combMode

LNAMDB

lnaModeDb

LNAPRED

lnaPredecessor

SCELLNO

secondCellNumber

WDLNA

wiringDataLna

GNADB

gainAdjustDb

System Responses:
Operation Completed
After command execution, a message of Changed Configuration Notification is displayed.
A further message indicates the result of the operation. An example of create command
is the following:
JOB: 92
PC Time&Date: 11:59:23 03/23/2005
NE Time&Date: 13:00:58 09/15/2004

A50016-G5100-B333-04-7619

Id:0900d805805944c2

313

DULNA

BS-4x / 82 II / 240 / 241 / 240XL commands

USER NAME:

User_pin

SW RELEASE:

01-04-17-01-26-51_05-02-23

COMMAND RESULT: Operation successful


ChangedConfigurationNotification:
name = RACK:0/DULNA:0
ChangeInfo = created
END OF OUTPUT FOR JOB 92
JOB: 93
PC Time&Date: 11:59:23 03/23/2005
NE Time&Date: 13:00:58 09/15/2004
USER NAME:

User_pin

COMMAND:
Create
DULNA:NAME=RACK:0/DULNA:0,CELLNO=0,COMBMD=OneToOne,WDLNA=CU0N;
SW RELEASE:

01-04-17-01-26-51_05-02-23

COMMAND RESULT: Operation successful


cellNumber = 0
combMode = OneToOne
secondCellNumber = 2
wiringDataLna = CU0N
gainAdjustDb = DIP
END OF OUTPUT FOR JOB 93
Operation Failed
The specified Object has not been created. In addition to the general NACK causes, a
specific NACK cause, which indicates that the command is inconsistent with the
physical configuration, is possible. An example is the following:
JOB: 94
PC Time&Date: 11:59:23 03/23/2005
NE Time&Date: 13:00:58 09/15/2004

314

Id:0900d805805944c2

A50016-G5100-B333-04-7619

BS-4x / 82 II / 240 / 241 / 240XL commands

DULNA

USER NAME:

User_pin

COMMAND:

Create DULNA:NAME=RACK:0/DULNA:2;

SW RELEASE:

01-04-17-01-26-51_05-02-23

COMMAND RESULT: OPERATION FAILED


Object instance unknown (-9)
END OF OUTPUT FOR JOB 94

Application Guidelines:

One DUAMCO contains two DUAMCO_LNA. The first DUAMCO within the rack is
put in the first slot, the second DUAMCO in the second slot and so on. This means
that DUAMCO_LNA 0 and DUAMCO_LNA 1 are always physically located in the
first slot within the rack, the DUAMCO_LNA 2 and DUAMCO_LNA 3 in the second
slot and so on

The DUAMCO_LNA and the CUs must be in the same rack and must belong to the
same cell

Each CU has a 'normal path' RX input and a 'diversity path' RX input and the
operator must indicate which of them is wired to the DUAMCO_LNA

If there is no wiring the operator must not provide a value for the attribute LNAPRED
(if a get is done the attribute identifier will be put into the list of unavailable attributes)

If there is no wiring for the attribute LNAPRED and the operator enters a value, this
error can be corrected by a deletion of the object and a re-creation of the object

The BTSE SW doesn't check if the entered "predecessor (relative number)" is compatible with typeOfBTSE; e.g. an input of TMA 11 is not rejected in a BS40 although
BS40 allows only the creation of TMA 0-5
The BTSE SW doesn't check if the entered "predecessor (rack)" is compatible with
typeOfBTSE; e.g. an input of RACK 1 is not rejected in a BS40 although BS40
allows only the creation of RACK 0

Wildcard addressing is not possible

The commands for the objects DULNA:2n and DULNA:2n+1 are not allowed if the
object DUAMCO:n exists and it is in the state OST.AVS = enabled.degraded (firmware download is active)

Example of Command Execution:


Create DULNA:NAME=RACK:1/DULNA:0,CELLNO=0,COMBMD=FourToOne,
SCELLNO=2,WDLNA=CU0N&CU1N&CU2N&CU3N,LNAPRED=DULNA-RACK00,GNADB=DIP,LNAMDB=<DIP>;

DELETE DULNA
DELETE DULNA

A50016-G5100-B333-04-7619

NAME=RACK:0..7/DULNA:0..11;

Id:0900d805805944c2

315

DULNA

BS-4x / 82 II / 240 / 241 / 240XL commands

Command Tree:
MANAGED-ELEMENT h BSS-EQUIPMENT h BTSEP h RACK h DULNA h
DELETE DULNA
Applicability:
Phase 2 and Phase 3.
Visibility level: 2.
Command Description:
This command deletes the DULNA (Low Noise Amplifier of Duplex Antenna Multicoupler) together with its attributes from the BTSE data base.
Long Names:
NAME

Address of the managed object

System Responses:
Operation Completed
After command execution, a message of Changed Configuration Notification is displayed. A further message indicates the result of the operation. An example of delete
command is the following:
JOB: 86
PC Time&Date: 11:58:47 03/23/2005
NE Time&Date: 13:00:22 09/15/2004
USER NAME:

User_pin

SW RELEASE:

01-04-17-01-26-51_05-02-23

COMMAND RESULT: Operation successful


ChangedConfigurationNotification:
name = RACK:0/DULNA:0
ChangeInfo = deleted
END OF OUTPUT FOR JOB 86
JOB: 87
PC Time&Date: 11:58:47 03/23/2005
NE Time&Date: 13:00:22 09/15/2004
USER NAME:

316

User_pin

Id:0900d805805944c2

A50016-G5100-B333-04-7619

BS-4x / 82 II / 240 / 241 / 240XL commands

COMMAND:

DULNA

Delete DULNA:NAME=RACK:0/DULNA:0;

SW RELEASE:

01-04-17-01-26-51_05-02-23

COMMAND RESULT: Operation successful


END OF OUTPUT FOR JOB 87
Operation Failed
The specified Object has not been deleted. Additionally to the general NACK causes, a
specific NACK cause, meaning that the command is inconsistent with physical configuration, is possible.
Application Guidelines:

DULNA must be locked in Phase 3, before deletion

If this object is deleted, the related TRXs are out of service

The commands for the objects DULNA:2n and DULNA:2n+1 are not allowed if the
object DUAMCO:n exists and it is in the state OST.AVS = enabled.degraded (firmware download is active)

Example of Command Execution:


Delete DULNA:NAME=RACK:0/DULNA:0;

GET DULNA
GET DULNA

NAME=RACK:0..7/DULNA:0..11 [,REQATTL=ALS, AST,


AVS, CELLNO, GNA, COMBMD, LNAMDB, LNAMODE,
LNAPRED, OST, PRS, RELFUNCOBJ, SCELLNO, WDLNA,
GNADB];

Command Tree:
MANAGED-ELEMENT h BSS-EQUIPMENT h BTSEP h RACK h DULNA h
GET DULNA
Applicability:
Phase 2 and Phase 3.
Visibility level: 0.
Command Description:
This command displays the attributes of the DULNA (Low Noise Amplifier of Duplex
Antenna Multicoupler).
Long Names:
NAME

Address of the managed object

REQATTL

Required attribute list

ALS

alarmStatus

AST

administrativeState

AVS

availabilityStatus

CELLNO

cellNumber

A50016-G5100-B333-04-7619

Id:0900d805805944c2

317

DULNA

BS-4x / 82 II / 240 / 241 / 240XL commands

GNA

gainAdjust(dB)

COMBMD

combMode

LNAMDB

lnaModeDb

LNAMODE

lnaMode

LNAPRED

lnaPredecessor

OST

operationalState

PRS

proceduralStatus

RELFUNCOBJ

relatedFuncObjects

SCELLNO

secondCellNumber

WDLNA

wiringDataLna

GNADB

gainAdjustDb

System Responses:
Operation Completed
A message indicates the result of the operation. An example of get command is the following:
JOB: 63
PC Time&Date: 11:58:17 03/23/2005
NE Time&Date: 12:59:52 09/15/2004
USER NAME:

User_pin

COMMAND:

Get DULNA:NAME=RACK:0/DULNA:0;

SW RELEASE:

01-04-17-01-26-51_05-02-23

COMMAND RESULT: Operation successful

alarmStatus = CLEARED
administrativeState = Unlocked
availabilityStatus = NULL
cellNumber = 0
cableLossAdjust(dB) = N_00
combMode = OneToOne
gainAdjustDb = N_00
lnaMode = AMCO_MODE
lnaModeDb = DIP
lnaPredecessor = Null
operationalState = ENABLED
proceduralStatus = NULL

318

Id:0900d805805944c2

A50016-G5100-B333-04-7619

BS-4x / 82 II / 240 / 241 / 240XL commands

DULNA

relatedFuncObjects =
secondCellNumber = NotUsed
wiringDataLna = CU1
END OF OUTPUT FOR JOB 63
Operation Failed
The GET command has not been successfully executed. A general NACK will indicate
possible errors or a specific NACK strictly related to the single command is possible.
Application Guidelines:

The value for the attribute relatedFuncObjects in LMT Phase 2 is "not configured"

The value for proceduralStatus must be NULL

Example of Command Execution:


Get
DULNA:NAME=RACK:0/DULNA:0,REQATTL=ALS&AST&AVS&CELLNO&GNA&CO
MBMD&RELFUNCOBJ&LNAMODE&LNAPRED&OST&PRS&SCELLNO&WDLNA;GNADB&LNAMDB;

GETTEST DULNA
GETTEST DULNA

NAME=RACK:0..7/DULNA:0..11;

Command Tree:
MANAGED-ELEMENT h BSS-EQUIPMENT h BTSEP h RACK h DULNA h
GETTEST DULNA
Applicability:
Phase 2 and Phase 3.
Visibility level: 0.
Command Description:
This command displays the attributes of the object test.
Long Names:
NAME

Address of the managed object

REQATTL

Required attribute list

System Responses:
Operation Completed
A message indicates the result of the operation. An example of gettest command is the
following:
JOB: 72
PC Time&Date: 11:58:33 03/23/2005

A50016-G5100-B333-04-7619

Id:0900d805805944c2

319

DULNA

BS-4x / 82 II / 240 / 241 / 240XL commands

NE Time&Date: 13:00:08 09/15/2004


USER NAME:

User_pin

COMMAND:

Gettest DULNA:NAME=RACK:0/DULNA:0;

SW RELEASE:

01-04-17-01-26-51_05-02-23

COMMAND RESULT: Operation successful


MOT = RACK:0/DULNA:0
testMonitor =
phaseId = PreliminaryTestsDulna
phaseStatus = Running
phaseId = CheckAlarmStatusDulna
phaseStatus = Waiting
phaseId = EndTestDulna
phaseStatus = Waiting
testOutcome = INCONCLUSIVE
testState = INITIALIZING
END OF OUTPUT FOR JOB 72
Operation Failed
The GET command has not been successfully executed. A general NACK will indicate
possible errors or a specific NACK strictly related to the single command is possible.
testMonitor
phaseId =
phaseStatus =

it is a list of all test phases related to the


selected object; for each phase the
related phaseStatus is provided (Passed,
Failed, Running or Waiting).

phaseId =
phaseStatus =
...
...
testOutcome

It represents the test result: it can be


Inconclusive (if the phases already
executed were successful) or Fail (if at
least one of the executed phases failed).

testState = Testing

It can assume one of the following values:


not_initialized, idle, initializing, suspended, testing, terminating and disabled.

Application Guidelines:
None.

320

Id:0900d805805944c2

A50016-G5100-B333-04-7619

BS-4x / 82 II / 240 / 241 / 240XL commands

DULNA

Example of Command Execution:


Gettest DULNA:NAME=RACK:0/DULNA:0;

LOCK DULNA
LOCK DULNA

NAME=RACK:0..7/DULNA:0..11;

Command Tree:
MANAGED-ELEMENT h BSS-EQUIPMENT h BTSEP h RACK h DULNA h
LOCK DULNA
Applicability:
Phase 2 and Phase 3.
Visibility level: 1.
Command Description:
This command changes the administrative state of DULNA (Low Noise Amplifier of
Duplex Antenna Multicoupler).
Long Names:
NAME

Address of the managed object

System Responses:
Operation Completed
The specified change of administrative state has been perfomed:
JOB: 73
PC Time&Date: 11:58:33 03/23/2005
NE Time&Date: 13:00:08 09/15/2004
USER NAME:

User_pin

COMMAND:

Lock DULNA:NAME=RACK:0/DULNA:0;

SW RELEASE:

01-04-17-01-26-51_05-02-23

COMMAND RESULT: Operation successful


administrativeState = Locked
END OF OUTPUT FOR JOB 73

CHANGED STATE EVENT REPORT:


This provides information about the administrative state, the operational state and the
availability status every time a state change occurs:

A50016-G5100-B333-04-7619

Id:0900d805805944c2

321

DULNA

BS-4x / 82 II / 240 / 241 / 240XL commands

JOB: 74
PC Time&Date: 11:58:33 03/23/2005
NE Time&Date: 13:00:08 09/15/2004
USER NAME:

User_pin

SW RELEASE:

01-04-17-01-26-51_05-02-23

COMMAND RESULT: Operation successful


CHANGED STATE EVENT REPORT:
NAME = RACK:0/DULNA:0
Administrative State = LOCKED
Notification Identifier = 301
END OF OUTPUT FOR JOB 74
Operation Failed
The specified change of administrative state has not been performed.
Application Guidelines:
The commands for the objects DULNA:2n and DULNA:2n+1 are not allowed if the object
DUAMCO:n exists and it is in the state OST.AVS = enabled.degraded (firmware
download is active).
While a Frequency Redefinition procedure is ongoing, the lock/unlock of all HMO's
actually related to a TRX is forbidden because that could lead to minor SELIC problem
or major SELIC problem alarms.

Example of Command Execution:


Lock DULNA:NAME=RACK:0/DULNA:0;

PERFTEST DULNA
PERFTEST DULNA

NAME=RACK:0..7/DULNA:0..11;

Command Tree:
MANAGED-ELEMENT h BSS-EQUIPMENT h BTSEP h RACK h DULNA h
PERFTEST DULNA
Applicability:
Phase 2 and Phase 3.
Visibility level: 1.

322

Id:0900d805805944c2

A50016-G5100-B333-04-7619

BS-4x / 82 II / 240 / 241 / 240XL commands

DULNA

Command Description:
This command is used to start an asynchronous test in the object.
Long Names:
NAME

Address of the managed object

System Responses:
Operation Completed
Test configuration has been set and the specified test has been started. The System
response will not be addressed to the MOT but to the object BTSEP.
JOB: 77
PC Time&Date: 11:58:39 03/23/2005
NE Time&Date: 13:00:14 09/15/2004
USER NAME:

User_pin

COMMAND:

Perftest DULNA:NAME=RACK:0/DULNA:0;

SW RELEASE:

01-04-17-01-26-51_05-02-23

COMMAND RESULT: Operation successful


MOT = RACK:0/DULNA:0
tO = BTSETEST:4
END OF OUTPUT FOR JOB 77
JOB: 78
PC Time&Date: 11:58:39 03/23/2005
NE Time&Date: 13:00:14 09/15/2004
USER NAME:

User_pin

SW RELEASE:

01-04-17-01-26-51_05-02-23

COMMAND RESULT: Operation successful


ChangedConfigurationNotification:
name = BTSETEST:4
ChangeInfo = created
END OF OUTPUT FOR JOB 78

A50016-G5100-B333-04-7619

Id:0900d805805944c2

323

DULNA

BS-4x / 82 II / 240 / 241 / 240XL commands

JOB: 79
PC Time&Date: 11:58:39 03/23/2005
NE Time&Date: 13:00:14 09/15/2004
USER NAME:

User_pin

SW RELEASE:

01-04-17-01-26-51_05-02-23

COMMAND RESULT: Operation successful


CHANGED STATE EVENT REPORT:
NAME = RACK:0/DULNA:0
Operational State = ENABLED
Availability Status = NULL_value
Notification Identifier = 305
END OF OUTPUT FOR JOB 79
JOB: 80
PC Time&Date: 11:58:39 03/23/2005
NE Time&Date: 13:00:14 09/15/2004
USER NAME:

User_pin

SW RELEASE:

01-04-17-01-26-51_05-02-23

COMMAND RESULT: Operation successful


Test Report:
name = BTSETEST:4
testOutcome = PASSED
testTermination = Normal
MOT = RACK:0/DULNA:0
executedPhases =
PreliminaryTestsDulna
CheckAlarmStatusDulna
EndTestDulna

324

Id:0900d805805944c2

A50016-G5100-B333-04-7619

BS-4x / 82 II / 240 / 241 / 240XL commands

DULNA

END OF OUTPUT FOR JOB 80


JOB: 81
PC Time&Date: 11:58:39 03/23/2005
NE Time&Date: 13:00:14 09/15/2004
USER NAME:

User_pin

SW RELEASE:

01-04-17-01-26-51_05-02-23

COMMAND RESULT: Operation successful


ChangedConfigurationNotification:
name = BTSETEST:4
ChangeInfo = deleted
END OF OUTPUT FOR JOB 81
The test results will be displayed at the end of the test phases.
Result TEST:
name =

TEST:<n>

testOutcome =

This field represents the test result; one of the following values can be displayed:
Pass

all the test phases are successfully


performed.

Inconclusive

the test is aborted by the system or


the test is terminated by the operator.

Fail

if at least one of the executed phases


fail.

mOts =

It is the identifier of the hardware object under test.

testTermination =

It specifies how the test is terminated, it can assume


the following values:
Normal

all the test phases are performed.

Abort

the test is aborted by system.

Cancel

the test is terminated by operator.

executedPhases
phaseId =
additionalWords =
....

A50016-G5100-B333-04-7619

It represents the list of the executed test phases (in


case of successful test result, all the test phases will
be listed).

Id:0900d805805944c2

325

DULNA

BS-4x / 82 II / 240 / 241 / 240XL commands

failedPhases
phaseId =

It represents the list of the failed test phase; additional information is provided for each phase.

phaseId =
....
skippedPhases
phaseId =

It represents the list of the skipped phases; they are


displayed only for test stopped during it execution.

phaseId =
....
poprosedRepair Action
=

A list of most probable fail probable causes is shown


(max four messages)

Operation Failed
This NACK-message occurs in the following cases: Message cannot be performed, test
not supported, capacity restrictions, physical configuration cannot be performed, object
not locked.
Application Guidelines:

In phase 3 MO must be locked previous to the command execution

Example of Command Execution:


Perftest DULNA:NAME=RACK:0/DULNA:0;

SET DULNA
SET DULNA

NAME=RACK:0..7/DULNA:0..11 [,LNAMDB=] [,SCELLNO=]


[,WDLNA=] [,GNADB=];

Command Tree:
MANAGED-ELEMENT h BSS-EQUIPMENT h BTSEP h RACK h DULNA h
SET DULNA
Applicability:
Phase 2 and Phase 3.
Visibility level: 2.
Command Description:
This command sets the attributes of the DULNA (Low Noise Amplifier of Duplex Antenna
Multicoupler) to the BTSE data base.
Long Names:

326

NAME

Address of the managed object

LNAMDB

lnaModeDb

SCELLNO

secondCellNumber

WDLNA

wiringDataLna

GNADB

gainAdjustDb

Id:0900d805805944c2

A50016-G5100-B333-04-7619

BS-4x / 82 II / 240 / 241 / 240XL commands

DULNA

System Responses:
Operation Completed
After command execution, a message of Changed Attribute Event Report is displayed.
A further message indicates the result of the operation. An example of set command is
the following:
JOB: 75
PC Time&Date: 11:58:36 03/23/2005
NE Time&Date: 13:00:11 09/15/2004
USER NAME:

User_pin

COMMAND:

Set DULNA:NAME=RACK:0/DULNA:0;

SW RELEASE:

01-04-17-01-26-51_05-02-23

COMMAND RESULT: Operation successful


END OF OUTPUT FOR JOB 75
Operation Failed
The specified attributes have not been set. In addition to the general NACK causes, a
specific NACK cause, which indicates that the command is inconsistent with the
physical configuration, is possible.
Application Guidelines:

One DUAMCO contains two DUAMCO_LNA. The first DUAMCO within the rack is
put in the first slot, the second DUAMCO in the second slot and so on. This means
that DUAMCO_LNA 0 and DUAMCO_LNA 1 are always physically located in the
first slot within the rack, the DUAMCO_LNA 2 and DUAMCO_LNA 3 in the second
slot and so on

The DUAMCO_LNA and the CUs must be in the same rack and must belong to the
same cell

Each CU has a 'normal path' RX input and a 'diversity path' RX input and the
operator must indicate which of them is wired to the DUAMCO_LNA

Wildcard addressing is not possible

All CUs which are listed in a previous GET DULNA for WDLNA have to be locked
(LOCK CU command) before one of these CUs can be removed from WDLNA.
Before locking these CUs first a shutdown of the TRXs related to these CUs should
be done

The commands for the objects DULNA:2n and DULNA:2n+1 are not allowed if the
object DUAMCO:n exists and it is in the state OST.AVS = enabled.degraded (firmware download is active)

Example of Command Execution:


Set DULNA:NAME=RACK:0/DULNA:0,SCELLNO=2,WDLNA=CU0N&CU1N&
CU2N&CU3N,GNADB=DIP,LNAMDB=<DIP>;

A50016-G5100-B333-04-7619

Id:0900d805805944c2

327

DULNA

BS-4x / 82 II / 240 / 241 / 240XL commands

STOPTEST DULNA
STOPTEST DULNA

NAME=RACK:0..7/DULNA:0..11;

Command Tree:
MANAGED-ELEMENT h BSS-EQUIPMENT h BTSEP h RACK h DULNA h
STOPTEST DULNA
Applicability:
Phase 2 and Phase 3.
Visibility level: 1.
Command Description:
This command is used to stop a diagnostic previously started.
Long Names:
NAME

Address of the managed object

System Responses:
Operation Completed
Test has been stopped. The System Responses will not be addressed to the MOT but
to the object BTSEP.

Result TEST:
name =

TEST:<n>

testOutcome =

inconclusive

mOts =

It is the identifier of the hardware object under test.

testTermination =

Cancel

executedPhases
phaseId =
...
.

It represents the list of the executed test phases; the


list is not shown for test in the waiting list (queued).

failedPhases
phaseId =

It represents the list of the failed test phase;

phaseId =

additional information is provided for each phase.

....
skippedPhases
phaseId =
phaseId =

It represents the list of the skipped phases;the list is


not shown for test in the waiting list (queued).

Operation Failed
Test has not been stopped. This NACK-message can occur when the specified test is
not running or in case of test which cannot be stopped.

328

Id:0900d805805944c2

A50016-G5100-B333-04-7619

BS-4x / 82 II / 240 / 241 / 240XL commands

DULNA

Application Guidelines:
None.
Example of Command Execution:
Stoptest DULNA:NAME=RACK:0/DULNA:0;

UNLOCK DULNA
UNLOCK DULNA

NAME=RACK:0..7/DULNA:0..11;

Command Tree:
MANAGED-ELEMENT h BSS-EQUIPMENT h BTSEP h RACK h DULNA h
UNLOCK DULNA
Applicability:
Phase 2 and Phase 3.
Visibility level: 1.
Command Description:
This command changes the administrative state of the DULNA (Duplex Antenna Multicoupler).
Long Names:
NAME

Address of the managed object

System Responses:
Operation Completed
The specified change of administrative state has been perfomed:
JOB: 82
PC Time&Date: 11:58:41 03/23/2005
NE Time&Date: 13:00:16 09/15/2004
USER NAME:

User_pin

COMMAND:

Unlock DULNA:NAME=RACK:0/DULNA:0;

SW RELEASE:

01-04-17-01-26-51_05-02-23

COMMAND RESULT: Operation successful


administrativeState = Unlocked
END OF OUTPUT FOR JOB 82

CHANGED STATE EVENT REPORT:

A50016-G5100-B333-04-7619

Id:0900d805805944c2

329

DULNA

BS-4x / 82 II / 240 / 241 / 240XL commands

This provides information about the administrative state, the operational state and the
availability status every time a state change occurs:
JOB: 83
PC Time&Date: 11:58:41 03/23/2005
NE Time&Date: 13:00:16 09/15/2004
USER NAME:

User_pin

SW RELEASE:

01-04-17-01-26-51_05-02-23

COMMAND RESULT: Operation successful


CHANGED STATE EVENT REPORT:
NAME = RACK:0/DULNA:0
Administrative State = UNLOCKED
Notification Identifier = 306
END OF OUTPUT FOR JOB 83
Operation Failed
The specified change of administrative state has not been performed.
Application Guidelines:
The commands for the objects DULNA:2n and DULNA:2n+1 are not allowed if the object
DUAMCO:n exists and it is in the state OST.AVS = enabled.degraded (firmware
download is active).
While a Frequency Redefinition procedure is ongoing, the lock/unlock of all HMO's
actually related to a TRX is forbidden because that could lead to minor SELIC problem
or major SELIC problem alarms.
Example of Command Execution:
Unlock DULNA:NAME=RACK:0/DULNA:0;

330

Id:0900d805805944c2

A50016-G5100-B333-04-7619

BS-4x / 82 II / 240 / 241 / 240XL commands

DUVSWR

DUVSWR
The DUVSWR object represents the VSWR of DUAMCO; a VSWR alarm indicates an
antenna failure.

CREATE DUVSWR
CREATE DUVSWR

NAME=RACK:0..7/DUVSWR:0..11 ,CELLNO= ,COMBMD=


,WDDUVSWR= [,VSWRTDB=];

Command Tree:
MANAGED-ELEMENT h BSS-EQUIPMENT h BTSEP h RACK h DUVSWR h
CREATE DUVSWR
Applicability:
Phase 2 and Phase 3.
Visibility level: 2.
Command Description:
This command adds the DUVSWR (Voltage Standing Wave Ratio Duplex Antenna Multicoupler) together with its attributes to the BTSE data base.
Long Names:
NAME

Address of the managed object

CELLNO

cellNumber

COMBMD

combMode

WDDUVSWR

wiringDuamcoVswr

VSWRTDB

vswrThresholdDb

System Responses:
Operation Completed
After command execution, a message of Changed Configuration Notification is displayed.
A further message indicates the result of the operation. An example of create command
is the following:
JOB: 112
PC Time&Date: 12:00:05 03/23/2005
NE Time&Date: 13:01:40 09/15/2004
USER NAME:

User_pon

SW RELEASE:

01-04-17-01-26-51_05-02-23

COMMAND RESULT: Operation successful

A50016-G5100-B333-04-7619

Id:0900d805805944c4

331

DUVSWR

BS-4x / 82 II / 240 / 241 / 240XL commands

ChangedConfigurationNotification:
name = RACK:0/DUVSWR:0
ChangeInfo = created
END OF OUTPUT FOR JOB 112
JOB: 113
PC Time&Date: 12:00:05 03/23/2005
NE Time&Date: 13:01:40 09/15/2004
USER NAME:

User_pon

COMMAND:
Create DUVSWR:NAME=RACK:0/DUVSWR:0,CELLNO=0,WDDUVSWR=CU0,COMBMD=OneToOne;
SW RELEASE:

01-04-17-01-26-51_05-02-23

COMMAND RESULT: Operation successful


cellNumber = 0
wiringDuamcoVswr = CU0
combMode = OneToOne
vswrThresholdDb = LOW_2_0_HIGH_3_0
END OF OUTPUT FOR JOB 113
Operation Failed
The specified Object has not been created. In addition to the general NACK causes, a
specific NACK cause, which indicates that the command is inconsistent with the
physical configuration, is possible. An example is the following:
JOB: 114
PC Time&Date: 12:00:05 03/23/2005
NE Time&Date: 13:01:40 09/15/2004
USER NAME:

User_pon

COMMAND:

Create DUVSWR:NAME=RACK:0/DUVSWR:2;

SW RELEASE:

01-04-17-01-26-51_05-02-23

COMMAND RESULT: OPERATION FAILED


Object instance unknown (-9)

332

Id:0900d805805944c4

A50016-G5100-B333-04-7619

BS-4x / 82 II / 240 / 241 / 240XL commands

DUVSWR

END OF OUTPUT FOR JOB 114

Application Guidelines:

One DUAMCO contains two DUAMCO_VSWR. The first DUAMCO within the rack
is put in the first slot, the second DUAMCO in the second slot and so on. This means
that DUAMCO_VSWR 0 and DUAMCO_VSWR 1 are always physically located in
the first slot within the rack, the DUAMCO_VSWR 2 and DUAMCO_VSWR 3 in the
second slot and so on

The DUAMCO_VSWR and the CUs must be in the same rack and must belong to
the same cell

Due to the physical properties of the DUAMCO_VSWR, up to 4 CUs can be connected

Wildcard addressing is not possible

The commands for the objects DUVSWR:2n and DUVSWR:2n+1 are not allowed if
the object DUAMCO:n exists and it is in the state OST.AVS = enabled.degraded
(firmware download is active)

Example of Command Execution:


Create DUVSWR:NAME=RACK:0/DUVSWR:0,CELLNO=0,COMBMD=TwoToTwo,
WDDUVSWR=CU0&CU1,VSWRTDB=LOW_2_0_HIGH_3_0;

DELETE DUVSWR
DELETE DUVSWR

NAME=RACK:0..7/DUVSWR:0..11;

Command Tree:
MANAGED-ELEMENT h BSS-EQUIPMENT h BTSEP h RACK h DUVSWR h
DELETE DUVSWR
Applicability:
Phase 2 and Phase 3.
Visibility level: 2.
Command Description:
This command deletes the DUVSWR (Voltage Standing Wave Ratio Duplex Antenna
Multicoupler) together with its attributes from the BTSE data base.
Long Names:
NAME

Address of the managed object

System Responses:
Operation Completed
After command execution, a message of Changed Configuration Notification is displayed. A further message indicates the result of the operation. An example of delete
command is the following:

A50016-G5100-B333-04-7619

Id:0900d805805944c4

333

DUVSWR

BS-4x / 82 II / 240 / 241 / 240XL commands

JOB: 110
PC Time&Date: 11:59:58 03/23/2005
NE Time&Date: 13:01:33 09/15/2004
USER NAME:

User_pon

SW RELEASE:

01-04-17-01-26-51_05-02-23

COMMAND RESULT: Operation successful


ChangedConfigurationNotification:
name = RACK:0/DUVSWR:0
ChangeInfo = deleted
END OF OUTPUT FOR JOB 110
JOB: 111
PC Time&Date: 11:59:58 03/23/2005
NE Time&Date: 13:01:33 09/15/2004
USER NAME:

User_pon

COMMAND:

Delete DUVSWR:NAME=RACK:0/DUVSWR:0;

SW RELEASE:

01-04-17-01-26-51_05-02-23

COMMAND RESULT: Operation successful


END OF OUTPUT FOR JOB 111
Operation Failed
The specified Object has not been deleted. Additionally to the general NACK causes, a
specific NACK cause, meaning that the command is inconsistent with physical configuration, is possible.
Application Guidelines:

334

DUVSWR must be locked in Phase 3, before deletion

If this object is deleted, the related TRXs are out of service

The commands for the objects DUVSWR:2n and DUVSWR:2n+1 are not allowed if
the object DUAMCO:n exists and it is in the state OST.AVS = enabled.degraded
(firmware download is active)

Id:0900d805805944c4

A50016-G5100-B333-04-7619

BS-4x / 82 II / 240 / 241 / 240XL commands

DUVSWR

Example of Command Execution:


Delete DUVSWR:NAME=RACK:0/DUVSWR:0;

GET DUVSWR
GET DUVSWR

NAME=RACK:0..7/DUVSWR:0..11 [,REQATTL=ALS, AST,


AVS, CELLNO, COMBMD, OST, PRS, RELFUNCOBJ,
WDDUVSWR, VSWRTDB];

Command Tree:
MANAGED-ELEMENT h BSS-EQUIPMENT h BTSEP h RACK h DUVSWR h
GET DUVSWR
Applicability:
Phase 2 and Phase 3.
Visibility level: 0.
Command Description:
This command displays the attributes of the DUVSWR (Voltage Standing Wave Ratio
Duplex Antenna Multicoupler).
Long Names:
NAME

Address of the managed object

REQATTL

Required attribute list

ALS

alarmStatus

AST

administrativeState

AVS

availabilityStatus

CELLNO

cellNumber

COMBMD

combMode

OST

operationalState

PRS

proceduralStatus

RELFUNCOBJ

relatedFuncObjects

WDDUVSWR

wiringDuamcoVswr

VSWRTDB

vswrThresholdDb

System Responses:
Operation Completed
A message indicates the result of the operation. An example of get command is the following:
JOB: 95
PC Time&Date: 11:59:35 03/23/2005
NE Time&Date: 13:01:10 09/15/2004

A50016-G5100-B333-04-7619

Id:0900d805805944c4

335

DUVSWR

BS-4x / 82 II / 240 / 241 / 240XL commands

USER NAME:

User_pon

COMMAND:

Get DUVSWR:NAME=RACK:0/DUVSWR:0;

SW RELEASE:

01-04-17-01-26-51_05-02-23

COMMAND RESULT: Operation successful


alarmStatus = CLEARED
administrativeState = Locked
availabilityStatus = NULL
cellNumber = 0
combMode = TwoToTwo
operationalState = ENABLED
proceduralStatus = NULL
relatedFuncObjects =
BTS:0/TRX:2
vswrThresholdDb = LOW_2_0_HIGH_3_0
wiringDuamcoVswr = CU0
END OF OUTPUT FOR JOB 95
Operation Failed
The GET command has not been successfully executed. A general NACK will indicate
possible errors or a specific NACK strictly related to the single command is possible.
Application Guidelines:

The value for the attribute gsmFunctionalID in LMT Phase 2 is "not configured"

The value for proceduralStatus must be NULL

Example of Command Execution:


Get DUVSWR:NAME=RACK:0/DUVSWR:0,REQATTL=ALS&AST&AVS&CELLNO&
COMBMD&OST&PRS&RELFUNCOBJ&WDDUVSWR&VSWRTDB;

GETTEST DUVSWR
GETTEST DUVSWR

NAME=RACK:0..7/DUVSWR:0..11;

Command Tree:
MANAGED-ELEMENT h BSS-EQUIPMENT h BTSEP h RACK h DUVSWR h
GETTEST DUVSWR
Applicability:
Phase 2 and Phase 3.
Visibility level: 0.
Command Description:
This command displays the attributes of the object test.

336

Id:0900d805805944c4

A50016-G5100-B333-04-7619

BS-4x / 82 II / 240 / 241 / 240XL commands

DUVSWR

Long Names:
NAME

Address of the managed object

REQATTL

Required attribute list

System Responses:
Operation Completed
A message indicates the result of the operation. An example of gettest command is the
following:
JOB: 101
PC Time&Date: 11:59:50 03/23/2005
NE Time&Date: 13:01:25 09/15/2004
USER NAME:

User_pon

COMMAND:

Gettest DUVSWR:NAME=RACK:0/DUVSWR:0;

SW RELEASE:

01-04-17-01-26-51_05-02-23

COMMAND RESULT: Operation successful


MOT = RACK:0/DUVSWR:0
testMonitor =
phaseId = PreliminaryTestsDuvswr
phaseStatus = Running
phaseId = CheckAlarmStatusDuvswr
phaseStatus = Waiting
phaseId = EndTestDuvswr
phaseStatus = Waiting
testOutcome = INCONCLUSIVE
testState = INITIALIZING
END OF OUTPUT FOR JOB 101
Operation Failed
The GET command has not been successfully executed. A general NACK will indicate
possible errors or a specific NACK strictly related to the single command is possible.

A50016-G5100-B333-04-7619

Id:0900d805805944c4

337

DUVSWR

BS-4x / 82 II / 240 / 241 / 240XL commands

testMonitor
phaseId =
phaseStatus =

it is a list of all test phases related to the


selected object; for each phase the
related phaseStatus is provided (Passed,
Failed, Running or Waiting).

phaseId =
phaseStatus =
...
...
testOutcome

It represents the test result: it can be


Inconclusive (if the phases already
executed were successful) or Fail (if at
least one of the executed phases failed).

testState = Testing

It can assume one of the following values:


not_initialized, idle, initializing, suspended, testing, terminating and disabled.

Application Guidelines:
None.
Example of Command Execution:
Gettest DUVSWR:NAME=RACK:0/DUVSWR:0;

LOCK DUVSWR
LOCK DUVSWR

NAME=RACK:0..7/DUVSWR:0..11;

Command Tree:
MANAGED-ELEMENT h BSS-EQUIPMENT h BTSEP h RACK h DUVSWR h
LOCK DUVSWR
Applicability:
Phase 2 and Phase 3.
Visibility level: 1.
Command Description:
This command changes the administrative state of DUVSWR (Voltage Standing Wave
Ratio Duplex Antenna Multicoupler).
Long Names:
NAME

Address of the managed object

System Responses:
Operation Completed
The specified change of administrative state has been perfomed:

338

Id:0900d805805944c4

A50016-G5100-B333-04-7619

BS-4x / 82 II / 240 / 241 / 240XL commands

DUVSWR

JOB: 99
PC Time&Date: 11:59:48 03/23/2005
NE Time&Date: 13:01:23 09/15/2004
USER NAME:

User_pon

COMMAND:

Lock DUVSWR:NAME=RACK:0/DUVSWR:0;

SW RELEASE:

01-04-17-01-26-51_05-02-23

COMMAND RESULT: Operation successful


administrativeState = Locked
END OF OUTPUT FOR JOB 99

CHANGED STATE EVENT REPORT:


This provides information about the administrative state, the operational state and the
availability status every time a state change occurs:
JOB: 100
PC Time&Date: 11:59:48 03/23/2005
NE Time&Date: 13:01:23 09/15/2004
USER NAME:

User_pon

SW RELEASE:

01-04-17-01-26-51_05-02-23

COMMAND RESULT: Operation successful


CHANGED STATE EVENT REPORT:
NAME = RACK:0/DUVSWR:0
Administrative State = LOCKED
Notification Identifier = 312
END OF OUTPUT FOR JOB 100
Operation Failed
The specified change of administrative state has not been performed.

A50016-G5100-B333-04-7619

Id:0900d805805944c4

339

DUVSWR

BS-4x / 82 II / 240 / 241 / 240XL commands

Application Guidelines:
The commands for the objects DUVSWR:2n and DUVSWR:2n+1 are not allowed if the
object DUAMCO:n exists and it is in the state OST.AVS = enabled.degraded (firmware
download is active).
While a Frequency Redefinition procedure is ongoing, the lock/unlock of all HMO's
actually related to a TRX is forbidden because that could lead to minor SELIC problem
or major SELIC problem alarms.

Example of Command Execution:


Lock DUVSWR:NAME=RACK:0/DUVSWR:0;

PERFTEST DUVSWR
PERFTEST DUVSWR

NAME=RACK:0..7/DUVSWR:0..11;

Command Tree:
MANAGED-ELEMENT h BSS-EQUIPMENT h BTSEP h RACK h DUVSWR h
PERFTEST DUVSWR
Applicability:
Phase 2 and Phase 3.
Visibility level: 1.
Command Description:
This command is used to start an asynchronous test in the object.
Long Names:
NAME

Address of the managed object

System Responses:
Operation Completed
Test configuration has been set and the specified test has been started. The System
response will not be addressed to the MOT but to the object BTSEP.
JOB: 102
PC Time&Date: 11:59:50 03/23/2005
NE Time&Date: 13:01:25 09/15/2004
USER NAME:

User_pon

COMMAND:

Perftest DUVSWR:NAME=RACK:0/DUVSWR:0;

SW RELEASE:

01-04-17-01-26-51_05-02-23

COMMAND RESULT: Operation successful


MOT = RACK:0/DUVSWR:0

340

Id:0900d805805944c4

A50016-G5100-B333-04-7619

BS-4x / 82 II / 240 / 241 / 240XL commands

DUVSWR

tO = BTSETEST:5
END OF OUTPUT FOR JOB 102
JOB: 103
PC Time&Date: 11:59:50 03/23/2005
NE Time&Date: 13:01:25 09/15/2004
USER NAME:

User_pon

SW RELEASE:

01-04-17-01-26-51_05-02-23

COMMAND RESULT: Operation successful


ChangedConfigurationNotification:
name = BTSETEST:5
ChangeInfo = created
END OF OUTPUT FOR JOB 103
JOB: 104
PC Time&Date: 11:59:50 03/23/2005
NE Time&Date: 13:01:25 09/15/2004
USER NAME:

User_pon

SW RELEASE:

01-04-17-01-26-51_05-02-23

COMMAND RESULT: Operation successful


CHANGED STATE EVENT REPORT:
NAME = RACK:0/DUVSWR:0
Operational State = ENABLED
Availability Status = NULL_value
Notification Identifier = 316
END OF OUTPUT FOR JOB 104
JOB: 105

A50016-G5100-B333-04-7619

Id:0900d805805944c4

341

DUVSWR

BS-4x / 82 II / 240 / 241 / 240XL commands

PC Time&Date: 11:59:50 03/23/2005


NE Time&Date: 13:01:25 09/15/2004
USER NAME:

User_pon

SW RELEASE:

01-04-17-01-26-51_05-02-23

COMMAND RESULT: Operation successful


Test Report:
name = BTSETEST:5
testOutcome = PASSED
testTermination = Normal
MOT = RACK:0/DUVSWR:0
executedPhases =
PreliminaryTestsDuvswr
CheckAlarmStatusDuvswr
EndTestDuvswr
END OF OUTPUT FOR JOB 105
JOB: 106
PC Time&Date: 11:59:50 03/23/2005
NE Time&Date: 13:01:25 09/15/2004
USER NAME:

User_pon

SW RELEASE:

01-04-17-01-26-51_05-02-23

COMMAND RESULT: Operation successful


ChangedConfigurationNotification:
name = BTSETEST:5
ChangeInfo = deleted
END OF OUTPUT FOR JOB 106
The test results will be displayed at the end of the test phases.
Result TEST:

342

Id:0900d805805944c4

A50016-G5100-B333-04-7619

BS-4x / 82 II / 240 / 241 / 240XL commands

DUVSWR

name =

TEST:<n>

testOutcome =

This field represents the test result; one of the following values can be displayed:
Pass

all the test phases are successfully


performed.

Inconclusive

the test is aborted by the system or


the test is terminated by the operator.

Fail

if at least one of the executed phases


fail.

mOts =

It is the identifier of the hardware object under test.

testTermination =

It specifies how the test is terminated, it can assume


the following values:
Normal

all the test phases are performed.

Abort

the test is aborted by system.

Cancel

the test is terminated by operator.

executedPhases
phaseId =
additionalWords =
....

It represents the list of the executed test phases (in


case of successful test result, all the test phases will
be listed).

failedPhases
phaseId =

It represents the list of the failed test phase; additional information is provided for each phase.

phaseId =
....
skippedPhases
phaseId =

It represents the list of the skipped phases; they are


displayed only for test stopped during it execution.

phaseId =
....
poprosedRepair Action
=

A list of most probable fail probable causes is shown


(max four messages)

Operation Failed
This NACK-message occurs in the following cases: Message cannot be performed, test
not supported, capacity restrictions, physical configuration cannot be performed, object
not locked.
Application Guidelines:

In phase 3 MO must be locked previous to the command execution

Example of Command Execution:


Perftest DUVSWR:NAME=RACK:0/DUVSWR:0;

A50016-G5100-B333-04-7619

Id:0900d805805944c4

343

DUVSWR

BS-4x / 82 II / 240 / 241 / 240XL commands

SET DUVSWR
SET DUVSWR

NAME=RACK:0..7/DUVSWR:0..11 [,WDDUVSWR=]
[,VSWRTDB=];

Command Tree:
MANAGED-ELEMENT h BSS-EQUIPMENT h BTSEP h RACK h DUVSWR h
SET DUVSWR
Applicability:
Phase 2 and Phase 3.
Visibility level: 2.
Command Description:
This command sets the attributes of the DUVSWR (Voltage Standing Wave Ratio
Duplex Antenna Multicoupler) to the BTSE data base.
Long Names:
NAME

Address of the managed object

WDDUVSWR

wiringDuamcoVswr

VSWRTDB

vswrThresholdDb

System Responses:
Operation Completed
After command execution, a message of Changed Attribute Event Report is displayed.
A further message indicates the result of the operation. An example of set command is
the following:
JOB: 109
PC Time&Date: 11:59:53 03/23/2005
NE Time&Date: 13:01:28 09/15/2004
USER NAME:

User_pon

COMMAND:

Set DUVSWR:NAME=RACK:0/DUVSWR:0;

SW RELEASE:

01-04-17-01-26-51_05-02-23

COMMAND RESULT: Operation successful


END OF OUTPUT FOR JOB 109
Operation Failed
The specified attributes have not been set. In addition to the general NACK causes, a
specific NACK cause, which indicates that the command is inconsistent with the
physical configuration, is possible.

344

Id:0900d805805944c4

A50016-G5100-B333-04-7619

BS-4x / 82 II / 240 / 241 / 240XL commands

DUVSWR

Application Guidelines:

One DUAMCO contains two DUAMCO_VSWR. The first DUAMCO within the rack
is put in the first slot, the second DUAMCO in the second slot and so on. This means
that DUAMCO_VSWR 0 and DUAMCO_VSWR 1 are always physically located in
the first slot within the rack, the DUAMCO_VSWR 2 and DUAMCO_VSWR 3 in the
second slot and so on

The DUAMCO_VSWR and the CUs must be in the same rack and must belong to
the same cell

Due to the physical properties of the DUAMCO_VSWR, up to 4 CUs can be connected

Wildcard addressing is not possible

All CUs which are listed in a previous GET DUVSWR for WDDUVSWR have to be
locked (LOCK CU command) before one of these CUs can be removed from
WDDUVSWR. Before locking these CUs first a shutdown of the TRXs related to
these CUs should be done

The commands for the objects DUVSWR:2n and DUVSWR:2n+1 are not allowed if
the object DUAMCO:n exists and it is in the state OST.AVS = enabled.degraded
(firmware download is active)

Example of Command Execution:


Set DUVSWR:NAME=RACK:0/DUVSWR:0,WDDUVSWR=CU0N&CU1N&CU2N&CU3N,VSWRTDB=LOW_2_0_HIGH_3_0;

STOPTEST DUVSWR
STOPTEST DUVSWR

NAME=RACK:0..7/DUVSWR:0..11;

Command Tree:
MANAGED-ELEMENT h BSS-EQUIPMENT h BTSEP h RACK h DUVSWR h
STOPTEST DUVSWR
Applicability:
Phase 2 and Phase 3.
Visibility level: 1.
Command Description:
This command is used to stop a diagnostic previously started.
Long Names:
NAME

Address of the managed object

System Responses:
Operation Completed
Test has been stopped. The System Responses will not be addressed to the MOT but
to the object BTSEP.

A50016-G5100-B333-04-7619

Id:0900d805805944c4

345

DUVSWR

BS-4x / 82 II / 240 / 241 / 240XL commands

Result TEST:
name =

TEST:<n>

testOutcome =

inconclusive

mOts =

It is the identifier of the hardware object under test.

testTermination =

Cancel

executedPhases
phaseId =

It represents the list of the executed test phases; the


list is not shown for test in the waiting list (queued).

...
.
failedPhases
phaseId =

It represents the list of the failed test phase;

phaseId =

additional information is provided for each phase.

....
skippedPhases
phaseId =

It represents the list of the skipped phases;the list is


not shown for test in the waiting list (queued).

phaseId =
Operation Failed

Test has not been stopped. This NACK-message can occur when the specified test is
not running or in case of test which cannot be stopped.
Application Guidelines:
None.
Example of Command Execution:
Stoptest DUVSWR:NAME=RACK:0/DUVSWR:0;

UNLOCK DUVSWR
UNLOCK DUVSWR

NAME=RACK:0..7/DUVSWR:0..11;

Command Tree:
MANAGED-ELEMENT h BSS-EQUIPMENT h BTSEP h RACK h DUVSWR h
UNLOCK DUVSWR
Applicability:
Phase 2 and Phase 3.
Visibility level: 1.
Command Description:
This command changes the administrative state of the DUVSWR (Voltage Standing
Wave Ratio Duplex Antenna Multicoupler).

346

Id:0900d805805944c4

A50016-G5100-B333-04-7619

BS-4x / 82 II / 240 / 241 / 240XL commands

DUVSWR

Long Names:
NAME

Address of the managed object

System Responses:
Operation Completed
The specified change of administrative state has been perfomed:
JOB: 97
PC Time&Date: 11:59:44 03/23/2005
NE Time&Date: 13:01:19 09/15/2004
USER NAME:

User_pon

COMMAND:

Unlock DUVSWR:NAME=RACK:0/DUVSWR:0;

SW RELEASE:

01-04-17-01-26-51_05-02-23

COMMAND RESULT: Operation successful


administrativeState = Unlocked
END OF OUTPUT FOR JOB 97

CHANGED STATE EVENT REPORT:


This provides information about the administrative state, the operational state and the
availability status every time a state change occurs:
JOB: 98
PC Time&Date: 11:59:44 03/23/2005
NE Time&Date: 13:01:19 09/15/2004
USER NAME:

User_pon

SW RELEASE:

01-04-17-01-26-51_05-02-23

COMMAND RESULT: Operation successful


CHANGED STATE EVENT REPORT:
NAME = RACK:0/DUVSWR:0
Administrative State = UNLOCKED
Notification Identifier = 311

A50016-G5100-B333-04-7619

Id:0900d805805944c4

347

DUVSWR

BS-4x / 82 II / 240 / 241 / 240XL commands

END OF OUTPUT FOR JOB 98


Operation Failed
The specified change of administrative state has not been performed.
Application Guidelines:
The commands for the objects DUVSWR:2n and DUVSWR:2n+1 are not allowed if the
object DUAMCO:n exists and it is in the state OST.AVS = enabled.degraded (firmware
download is active).
While a Frequency Redefinition procedure is ongoing, the lock/unlock of all HMO's
actually related to a TRX is forbidden because that could lead to minor SELIC problem
or major SELIC problem alarms.
Example of Command Execution:
Unlock DUVSWR:NAME=RACK:0/DUVSWR:0;

348

Id:0900d805805944c4

A50016-G5100-B333-04-7619

BS-4x / 82 II / 240 / 241 / 240XL commands

ENVABTSE

ENVABTSE
The ENVABTSE object is used to manage the enviromental alarms of the BTSE.

CREATE ENVABTSE
CREATE ENVABTSE

NAME=RACK:0..7/ENVABTSE:0..56 [,ASEV=]
[,ASTRING=] ,INTINF=;

Command Tree:
MANAGED-ELEMENT h BSS-EQUIPMENT h BTSEP h RACK h ENVABTSE
h CREATE ENVABTSE
Applicability:
Phase 2 and Phase 3.
Visibility level: 2.
Command Description:
This command configures one of the 9 possible environmental alarms (in the Base Rack
optionally the ACTM can be installed that supplies 48 additional ENVAs) in the BTSE
database (BS40/41, BS240/241, BS240XL, BS40II).
For BS82II this command configures one of the 6 possible environmental alarms.
Long Names:
NAME

Address of the managed object

ASEV

associatedSeverity

ASTRING

associatedString

INTINF

interfaceInformation

System Responses:
Operation Completed
After command execution, a message of Changed Configuration Notification is displayed.
A further message indicates the result of the operation. An example of create command
is the following:
JOB: 116
PC Time&Date: 12:00:26 03/23/2005
NE Time&Date: 13:02:01 09/15/2004
USER NAME:

User_titti

SW RELEASE:

01-04-17-01-26-51_05-02-23

COMMAND RESULT: Operation successful

A50016-G5100-B333-04-7619

Id:0900d805805944c6

349

ENVABTSE

BS-4x / 82 II / 240 / 241 / 240XL commands

ChangedConfigurationNotification:
name = RACK:0/ENVABTSE:0
ChangeInfo = created
END OF OUTPUT FOR JOB 116
JOB: 117
PC Time&Date: 12:00:26 03/23/2005
NE Time&Date: 13:02:01 09/15/2004
USER NAME:

User_titti

COMMAND:

Create ENVABTSE:NAME=RACK:0/ENVABTSE:0,INTINF=low;

SW RELEASE:

01-04-17-01-26-51_05-02-23

COMMAND RESULT: Operation successful


interfaceInformation = low
END OF OUTPUT FOR JOB 117
Operation Failed
The specified Object has not been created. In addition to the general NACK causes, a
specific NACK cause, which indicates that the command is inconsistent with the
physical configuration, is possible. An example is the following:
JOB: 119
PC Time&Date: 12:00:31 03/23/2005
NE Time&Date: 13:02:06 09/15/2004
USER NAME:

User_titti

COMMAND:

Create ENVABTSE:NAME=RACK:0/ENVABTSE:1,INTINF=high;

SW RELEASE:

01-04-17-01-26-51_05-02-23

COMMAND RESULT: OPERATION FAILED


Message cannot be performed (-17)
END OF OUTPUT FOR JOB 119

350

Id:0900d805805944c6

A50016-G5100-B333-04-7619

BS-4x / 82 II / 240 / 241 / 240XL commands

ENVABTSE

Application Guidelines:
For BS241:

All ENVAs can be left as not equipped

In the Base Rack with only ACTC installed 9 ENVAs within the range from 0...8 are
supported as shown in the table below. In the Base Rack optionally the ACTM can
be installed that supplies 48 additional ENVAs

In the other Racks with ACTC installed 9 ENVAs within the range from 0...8 are supported as shown in the table below
ENVA No.

Application

Heatexchanger - 0

Heatexchanger - 1

Heatexchanger - 2

Rack/Shelter in service

Smoke

Battery Fuse 0, 1, 2

Over Voltage Protection (it has to be configured with "HIGH")

7
8

Microwave

For BS240 Compact Site:


The AC/DC alarm line for the AC/DC converter and for the battery must be connected to a site input which is used as a trigger for the emergency configuration.
A special setting of the attribute "associatedString" in the corresponding site input
allows the operator to indicate that the support of emergency configuration is
required for the 3rd party battery backup unit system. The string indicates from
which source, AC/DC CAN node or site input, the trigger for the emergency configuration is expected. In case the string pattern is set to "##ACDC_FAULT" the trigger
is expected from the site input of the corresponding ENVABTSE object. In all other
cases the normal behavior is maintained.
For simplicity there is no check if the string "##ACDC_FAULT" is used for more than
one ENVABTSE object. If the operator has set the "associatedString" attribute of an
ENVABTSE object to "##ACDC_FAULT" for the AC/DC alarm line, the emergency
configuration is deactivated if all trigger sources have ceased their alarm.
ENVA No.

Application

Severity

String

HIGH

CRITICAL

Over Voltage Protection ()

HIGH

CRITICAL

Shelter door open

10

HIGH

CRITICAL

Conditioners FAULT

A50016-G5100-B333-04-7619

Id:0900d805805944c6

351

ENVABTSE

BS-4x / 82 II / 240 / 241 / 240XL commands

11

HIGH

CRITICAL

Shelter Temperature Out Tolerance

12

HIGH

CRITICAL

Shelter in service

13

HIGH

CRITICAL

Not connected

14

HIGH

CRITICAL

Mains Breakdown

15

HIGH

CRITICAL

Critical Battery Breakdown

16

HIGH

CRITICAL

Critical Battery Charging Fault

17

HIGH

CRITICAL

-48 dc Out Tolerance

18

HIGH

CRITICAL

Redundancy Lost

19

HIGH

CRITICAL

Not connected

20

HIGH

CRITICAL

Not connected

21

HIGH

CRITICAL

Not connected

22

HIGH

CRITICAL

Not connected

27

HIGH

CRITICAL

Critical Smoke

28

HIGH

CRITICAL

Critical Available 1

29

HIGH

CRITICAL

Critical Available 2

30

HIGH

CRITICAL

Critical AC lightning Protection

31

HIGH

CRITICAL

Critical Available 3

32

HIGH

CRITICAL

Critical Available 4

33

HIGH

CRITICAL

Critical Available 5

34

HIGH

CRITICAL

Critical Conditioner ALM

34

HIGH

CRITICAL

Critical Filters ALM

36

HIGH

CRITICAL

Critical Available 6

37

HIGH

CRITICAL

Critical Available 7

38

HIGH

CRITICAL

Critical Available 8

39

HIGH

CRITICAL

Critical Available 9

40

HIGH

CRITICAL

Critical Available 10

For BS40II:
The FAN5 alarm is not utilized in the case of a BS-40II (deactivated by S/W).
ACTC-3 alarms
ENVA No.

352

High / Low Active

High / Low Active

High / Low Active Mains Breackdown (MBR) note 1 and 2

High / Low Active Battery Breackdown (BBR) note 1

Id:0900d805805944c6

A50016-G5100-B333-04-7619

BS-4x / 82 II / 240 / 241 / 240XL commands

ENVABTSE

SMOKE - High / Low Active

Battery Breacker (BB) - High / Low Active

Over Voltage Protection(OVP) - High / Low Active

High / Low Active - Battery Charger Fault (BCHF) note 1

High / Low Active - -48Vdc Out of Tolerance (48OTB) note 1

Note:
1. Only relevant for BS with AC/DC system, all AC/DC alarms are "High Active".
2. For MBR alarm the 'associated string' must be: '##ACDC_FAULT' to make this
alarm trigger the 'emergency configuration'.'emergency configuration'
Example of Command Execution:
Create ENVABTSE:NAME=RACK:0/ENVABTSE:17,INTINF=high,
ASEV=CRITICAL, ASTRING="Air Condition. Sys. Fault";

DELETE ENVABTSE
DELETE ENVABTSE

NAME=RACK:0..7/ENVABTSE:0..56;

Command Tree:
MANAGED-ELEMENT h BSS-EQUIPMENT h BTSEP h RACK h ENVABTSE
h DELETE ENVABTSE
Applicability:
Phase 2 and Phase 3.
Visibility level: 2.
Command Description:
BS24x, BS4x
This command deletes one of the 9 possible environmental alarms (in the Base Rack
optionally the ACTM can be installed that supplies 48 additional ENVAs) from the BTSE
database.
Long Names:
NAME

Address of the managed object

System Responses:
Operation Completed
After command execution, a message of Changed Configuration Notification is displayed. A further message indicates the result of the operation. An example of delete
command is the following:
JOB: 130
PC Time&Date: 12:00:52 03/23/2005

A50016-G5100-B333-04-7619

Id:0900d805805944c6

353

ENVABTSE

BS-4x / 82 II / 240 / 241 / 240XL commands

NE Time&Date: 13:02:27 09/15/2004


USER NAME:

User_titti

SW RELEASE:

01-04-17-01-26-51_05-02-23

COMMAND RESULT: Operation successful


ChangedConfigurationNotification:
name = RACK:0/ENVABTSE:0
ChangeInfo = deleted
END OF OUTPUT FOR JOB 130
JOB: 131
PC Time&Date: 12:00:52 03/23/2005
NE Time&Date: 13:02:27 09/15/2004
USER NAME:

User_titti

COMMAND:

Delete ENVABTSE:NAME=RACK:0/ENVABTSE:0;

SW RELEASE:

01-04-17-01-26-51_05-02-23

COMMAND RESULT: Operation successful


END OF OUTPUT FOR JOB 131
Operation Failed
The specified Object has not been deleted. Additionally to the general NACK causes, a
specific NACK cause, meaning that the command is inconsistent with physical configuration, is possible.
Application Guidelines:

ENVABTSE must be locked in phase 3 before deletion

Example of Command Execution:


Delete ENVABTSE:NAME=RACK:0/ENVABTSE:17;

GET ENVABTSE
GET ENVABTSE

354

NAME=RACK:0..7/ENVABTSE:0..56 [,REQATTL=ALS,
ASEV, AST, ASTRING, AVS, INTINF, OST, PRS, RELFUNCOBJ];

Id:0900d805805944c6

A50016-G5100-B333-04-7619

BS-4x / 82 II / 240 / 241 / 240XL commands

ENVABTSE

Command Tree:
MANAGED-ELEMENT h BSS-EQUIPMENT h BTSEP h RACK h ENVABTSE
h GET ENVABTSE
Applicability:
Phase 2 and Phase 3.
Visibility level: 0.
Command Description:
This command displays the attributes of the specified Environmental Alarm stored in the
BTSE database.
Long Names:
NAME

Address of the managed object

REQATTL

Required attribute list

ALS

alarmStatus

ASEV

associatedSeverity

AST

administrativeState

ASTRING

associatedString

AVS

availabilityStatus

INTINF

interfaceInformation

OST

operationalState

PRS

proceduralStatus

RELFUNCOBJ

relatedFuncObjects

System Responses:
Operation Completed
A message indicates the result of the operation. An example of get command is the following:
JOB: 118
PC Time&Date: 12:00:29 03/23/2005
NE Time&Date: 13:02:04 09/15/2004
USER NAME:

User_titti

COMMAND:

Get ENVABTSE:NAME=RACK:0/ENVABTSE:0;

SW RELEASE:

01-04-17-01-26-51_05-02-23

COMMAND RESULT: Operation successful


alarmStatus = CLEARED
associatedSeverity = DEFAULT_DB
administrativeState = Unlocked

A50016-G5100-B333-04-7619

Id:0900d805805944c6

355

ENVABTSE

BS-4x / 82 II / 240 / 241 / 240XL commands

associatedString =
availabilityStatus = NULL
interfaceInformation = low
operationalState = ENABLED
proceduralStatus = NULL
relatedFuncObjects =
END OF OUTPUT FOR JOB 118
Operation Failed
The GET command has not been successfully executed. A general NACK will indicate
possible errors or a specific NACK strictly related to the single command is possible.
Application Guidelines:

For BS24x all environmental alarms can be left as not equipped (default value)

See Application Guidelines: in CREATE ENVABTSE command for more detailed


information

Example of Command Execution:


Get ENVABTSE:NAME=RACK:0/ENVABTSE:17,REQATTL=ALS&ASEV&
ASTRING&AST&AVS&INTINF&OST&PRS&RELFUNCOBJ;

LOCK ENVABTSE
LOCK ENVABTSE

NAME=RACK:0..7/ENVABTSE:0..56;

Command Tree:
MANAGED-ELEMENT h BSS-EQUIPMENT h BTSEP h RACK h ENVABTSE
h LOCK ENVABTSE
Applicability:
Phase 2 and Phase 3.
Visibility level: 1.
Command Description:
This command changes the administrative state of the environmental alarms.
Long Names:
NAME

Address of the managed object

System Responses:
Operation Completed
The specified change of administrative state has been perfomed:
JOB: 128

356

Id:0900d805805944c6

A50016-G5100-B333-04-7619

BS-4x / 82 II / 240 / 241 / 240XL commands

ENVABTSE

PC Time&Date: 12:00:47 03/23/2005


NE Time&Date: 13:02:22 09/15/2004
USER NAME:

User_titti

COMMAND:

Lock ENVABTSE:NAME=RACK:0/ENVABTSE:0;

SW RELEASE:

01-04-17-01-26-51_05-02-23

COMMAND RESULT: Operation successful


administrativeState = Locked
END OF OUTPUT FOR JOB 1286

CHANGED STATE EVENT REPORT:


This provides information about the administrative state, the operational state and the
availability status every time a state change occurs:
JOB: 129
PC Time&Date: 12:00:47 03/23/2005
NE Time&Date: 13:02:22 09/15/2004
USER NAME:

User_titti

SW RELEASE:

01-04-17-01-26-51_05-02-23

COMMAND RESULT: Operation successful


CHANGED STATE EVENT REPORT:
NAME = RACK:0/ENVABTSE:0
Administrative State = LOCKED
Notification Identifier = 332
END OF OUTPUT FOR JOB 129
Operation Failed
The specified change of administrative state has not been performed.
Application Guidelines:

If the administrative state is set to locked, no alarms will be caused

Example of Command Execution:


Lock ENVABTSE:NAME=RACK:0/ENVABTSE:0;

A50016-G5100-B333-04-7619

Id:0900d805805944c6

357

ENVABTSE

BS-4x / 82 II / 240 / 241 / 240XL commands

SET ENVABTSE
SET ENVABTSE

NAME=RACK:0..7/ENVABTSE:0..56 [,INTINF=];

Command Tree:
MANAGED-ELEMENT h BSS-EQUIPMENT h BTSEP h RACK h ENVABTSE
h SET ENVABTSE
Applicability:
Phase 2 and Phase 3.
Visibility level: 2.
Command Description:
This command configures one of the 9 possible environmental alarms (in the Base Rack
optionally the ACTM can be installed that supplies 48 additional ENVAs) in the BTSE
database.
Long Names:
NAME

Address of the managed object

INTINF

interfaceInformation

System Responses:
Operation Completed
After command execution, a message of Changed Attribute Event Report is displayed.
A further message indicates the result of the operation. An example of set command is
the following:
JOB: 125
PC Time&Date: 12:00:39 03/23/2005
NE Time&Date: 13:02:14 09/15/2004
USER NAME:

User_titti

COMMAND:

Set ENVABTSE:NAME=RACK:0/ENVABTSE:0;

SW RELEASE:

01-04-17-01-26-51_05-02-23

COMMAND RESULT: Operation successful


END OF OUTPUT FOR JOB 125
Operation Failed
The specified attributes have not been set. In addition to the general NACK causes, a
specific NACK cause, which indicates that the command is inconsistent with the
physical configuration, is possible.
Application Guidelines:

358

For BS24x all environmental alarms can be left as not equipped (default value)

Id:0900d805805944c6

A50016-G5100-B333-04-7619

BS-4x / 82 II / 240 / 241 / 240XL commands

ENVABTSE

See Application Guidelines: in CREATE ENVABTSE command for more detailed


information

For BS41 and BS241 the smoke alarm must be set on low-active or high-active
depending on the respective installed sensor type

Example of Command Execution:


Set ENVABTSE:NAME=RACK:0/ENVABTSE:4,INTINF=high;

UNLOCK ENVABTSE
UNLOCK ENVABTSE

NAME=RACK:0..7/ENVABTSE:0..56;

Command Tree:
MANAGED-ELEMENT h BSS-EQUIPMENT h BTSEP h RACK h ENVABTSE
h UNLOCK ENVABTSE
Applicability:
Phase 2 and Phase 3.
Visibility level: 1.
Command Description:
This command changes the administrative state of the environmental alarms.
Long Names:
NAME

Address of the managed object

System Responses:
Operation Completed
The specified change of administrative state has been perfomed:
JOB: 126
PC Time&Date: 12:00:41 03/23/2005
NE Time&Date: 13:02:16 09/15/2004
USER NAME:

User_titti

COMMAND:

Unlock ENVABTSE:NAME=RACK:0/ENVABTSE:0;

SW RELEASE:

01-04-17-01-26-51_05-02-23

COMMAND RESULT: Operation successful


administrativeState = Unlocked
END OF OUTPUT FOR JOB 126

A50016-G5100-B333-04-7619

Id:0900d805805944c6

359

ENVABTSE

BS-4x / 82 II / 240 / 241 / 240XL commands

CHANGED STATE EVENT REPORT:


This provides information about the administrative state, the operational state and the
availability status every time a state change occurs:
JOB: 127
PC Time&Date: 12:00:41 03/23/2005
NE Time&Date: 13:02:16 09/15/2004
USER NAME:

User_titti

SW RELEASE:

01-04-17-01-26-51_05-02-23

COMMAND RESULT: Operation successful


CHANGED STATE EVENT REPORT:
NAME = RACK:0/ENVABTSE:0
Administrative State = UNLOCKED
Notification Identifier = 330
END OF OUTPUT FOR JOB 127
Operation Failed
The specified change of administrative state has not been performed.
Application Guidelines:
None.
Example of Command Execution:
Unlock ENVABTSE:NAME=RACK:0/ENVABTSE:0;

360

Id:0900d805805944c6

A50016-G5100-B333-04-7619

BS-4x / 82 II / 240 / 241 / 240XL commands

ETHCON

ETHCON
The ETHCON board provides external electrical and optical Ethernet interfaces to
connect the BSC, other BTS in multidrop-like configurations and test equipment for Abis
monitoring.
It therefore houses a manageable Ethernet switch which is controlled by the COBA.
Nevertheless the board is able to operate autonomously from the COBA in order to
maintain multidrop-like connections to other BTSE e.g. in case of a COBA reset.
The ETHCON board (ETHernet CONnection) is modeled by:

one ETHCON instance representing the board

n ETHPORT instances representing the external Ethernet ports (except for monitoring port(s))

The ETHCON object is introduced for state indication and alarm reporting. The object
state comprise the board, the traffic link and the switch management link to the COBA.

CREATE ETHCON
CREATE ETHCON

NAME=RACK:0..7/ETHCON:0..0;

Command Tree:
MANAGED-ELEMENT h BSS-EQUIPMENT h BTSEP h RACK h ETHCON h
CREATE ETHCON
Applicability:
Phase 2.
Visibility level: 2.
Command Description:
This command adds an Ethernet Connection board to the BTSE data base.
Long Names:
NAME

Address of the managed object

System Responses:
Operation Completed
After command execution, a message of Changed Configuration Notification is displayed.
A further message indicates the result of the operation. An example of create command
is the following:
JOB: 1154
PC Time&Date: 01.04.2008 08:23:43 +02:00
NE Time&Date: 01.01.1990 12:57:35 +00:00
USER NAME:

Brad_1i

COMMAND:

CREATE ETHCON:NAME = RACK:0/ETHCON:0;

SW RELEASE:

A50016-G5100-B333-04-7619

01-04-19-01-07-00_08-03-19

Id:0900d805805944ca

361

ETHCON

BS-4x / 82 II / 240 / 241 / 240XL commands

COMMAND RESULT: Operation successful


END OF OUTPUT FOR JOB 1154
Operation Failed
None.
Application Guidelines:
The creation is rejected if a COBA2P8 or COBA4P12 is already equipped.
Example of Command Execution:
Create ETHCON:NAME=RACK:0/ETHCON:0;

DELETE ETHCON
DELETE ETHCON

NAME=RACK:0..7/ETHCON:0..0;

Command Tree:
MANAGED-ELEMENT h BSS-EQUIPMENT h BTSEP h RACK h ETHCON h
DELETE ETHCON
Applicability:
Phase 2.
Visibility level: 2.
Command Description:
This command deletes the ETHCON (ETHernet CONnection) board from the BTSE
data base.
Long Names:
NAME

Address of the managed object

System Responses:
Operation Completed
None.
Operation Failed
None.
Application Guidelines:
The deletion is rejected as long as an ETHPORT and/or CESTUNNEL object exists.
Example of Command Execution:
Delete ETHCON:NAME=RACK:0/ETHCON:0;

GET ETHCON
GET ETHCON

362

NAME=RACK:0..7/ETHCON:0..0 [,REQATTL=ALS, AST,


AVS, OST, PRS, FWVER, RELFUNCOBJ, MONPRT];

Id:0900d805805944ca

A50016-G5100-B333-04-7619

BS-4x / 82 II / 240 / 241 / 240XL commands

ETHCON

Command Tree:
MANAGED-ELEMENT h BSS-EQUIPMENT h BTSEP h RACK h ETHCON h
GET ETHCON
Applicability:
Phase 2 and Phase 3.
Visibility level: 0.
Command Description:
This command displays the attributes of the ETHCON.
Long Names:
NAME

Address of the managed object

REQATTL

Required attribute list

ALS

alarmStatus

AST

administrativeState

AVS

availabilityStatus

OST

operationalState

PRS

proceduralStatus

FWVER

firmwareVersion

RELFUNCOBJ
MONPRT

relatedFuncObjects
monitoringPort

System Responses:
Operation Completed
A message indicates the result of the operation. An example of get command is the following:
JOB: 1244
PC Time&Date: 01.04.2008 08:29:03 +02:00
NE Time&Date: 01.01.1990 13:02:55 +00:00
USER NAME:

Brad_1i

COMMAND:

GET ETHCON:NAME=RACK:0/ETHCON:0;

SW RELEASE:

01-04-19-01-07-00_08-03-19

COMMAND RESULT: Operation successful

alarmStatus = CLEARED
administrativeState = Unlocked
availabilityStatus = NULL

A50016-G5100-B333-04-7619

Id:0900d805805944ca

363

ETHCON

BS-4x / 82 II / 240 / 241 / 240XL commands

operationalState = ENABLED
proceduralStatus = NULL
relatedFuncObjects = Null
monitoringPort = none
END OF OUTPUT FOR JOB 1244
Operation Failed
None.
Application Guidelines:
None.
Example of Command Execution:
Get ETHCON:NAME=RACK:0/ETHCON:0,REQATTL=ALS&AST&AVS&OST& PRS&
FWVER &RELFUNCOBJ& MONPRT;

LOCK ETHCON
LOCK ETHCON

NAME=RACK:0..7/ETHCON:0..0;

Command Tree:
MANAGED-ELEMENT h BSS-EQUIPMENT h BTSEP h RACK h ETHCON h
LOCK ETHCON
Applicability:
Phase 2.
Visibility level: 1.
Command Description:
This command changes the administrative state of ETHCON board.
Long Names:
NAME

Address of the managed object

System Responses:
Operation Completed
The specified change of administrative state has been perfomed:
JOB: 18
PC Time&Date: 08.02.2008 13:13:04 +01:00
NE Time&Date: 01.01.1990 00:40:00 +00:00

364

USER NAME:

Brad_1i

COMMAND:

Unlock ETHCON:NAME=RACK:0/ETHCON:0;

Id:0900d805805944ca

A50016-G5100-B333-04-7619

BS-4x / 82 II / 240 / 241 / 240XL commands

SW RELEASE:

ETHCON

01-04-19-01-01-CR_08-02-08

COMMAND RESULT: Operation successful

administrativeState = Unlocked
END OF OUTPUT FOR JOB 18
Operation Failed
None.
Application Guidelines:
None.
Example of Command Execution:
Lock ETHCON:NAME=RACK:0/ETHCON:0;

SET ETHCON
SET ETHCON

NAME=RACK:0..7/ETHCON:0..0 [,MONPRT=];

Command Tree:
MANAGED-ELEMENT h BSS-EQUIPMENT h BTSEP h RACK h ETHCON h
SET ETHCON
Applicability:
Phase 2 and Phase 3.
Visibility level: 2.
Command Description:
This command sets the attributes of ETHCON board to the BTSE data base.
Long Names:
NAME

Address of the managed object

MONPRT

monitoringPort

System Responses:
Operation Completed
After command execution, a message of Changed Configuration Notification is displayed.
A further message indicates the result of the operation. An example of set command is
the following:
OB: 22
PC Time&Date: 08.02.2008 13:13:19 +01:00
NE Time&Date: 01.01.1990 00:40:15 +00:00

A50016-G5100-B333-04-7619

Id:0900d805805944ca

365

ETHCON

BS-4x / 82 II / 240 / 241 / 240XL commands

USER NAME:

Brad_1i

COMMAND:

Set ETHCON:NAME=RACK:0/ETHCON:0,MONPRT=port3;

SW RELEASE:

01-04-19-01-01-CR_08-02-08

COMMAND RESULT: Operation successful

monitoringPort = port3
END OF OUTPUT FOR JOB 22
Operation Failed
None.
Application Guidelines:
None.
Example of Command Execution:
Set ETHCON:NAME=RACK:0/ETHCON:0,MONPRT=coba;

UNLOCK ETHCON
UNLOCK ETHCON

NAME=RACK:0..7/ETHCON:0..0;

Command Tree:
MANAGED-ELEMENT h BSS-EQUIPMENT h BTSEP h RACK h ETHCON h
UNLOCK ETHCON
Applicability:
Phase 2.
Visibility level: 1.
Command Description:
This command changes the administrative state of the ETHCON board.
Long Names:
NAME

Address of the managed object

System Responses:
Operation Completed
The specified change of administrative state has been perfomed:
JOB: 18
PC Time&Date: 08.02.2008 13:13:04 +01:00
NE Time&Date: 01.01.1990 00:40:00 +00:00

366

Id:0900d805805944ca

A50016-G5100-B333-04-7619

BS-4x / 82 II / 240 / 241 / 240XL commands

ETHCON

USER NAME:

Brad_1i

COMMAND:

Unlock ETHCON:NAME=RACK:0/ETHCON:0;

SW RELEASE:

01-04-19-01-01-CR_08-02-08

COMMAND RESULT: Operation successful

administrativeState = Unlocked
END OF OUTPUT FOR JOB 18
Operation Failed
None.
Application Guidelines:
None.
Example of Command Execution:
Unlock ETHCON:NAME=RACK:0/ETHCON:0;

A50016-G5100-B333-04-7619

Id:0900d805805944ca

367

ETHPORT

BS-4x / 82 II / 240 / 241 / 240XL commands

ETHPORT
The ETHPORT object is introduced to indicate the state of the Ethernet port and to allow
the configuration of port specific attributes. There is no ETHPORT instance for Ethernet
ports which are not externally visible (connection to COBA) nor used for monitoring.
The Ethernet port supports full duplex mode.

CREATE ETHPORT
CREATE ETHPORT

NAME=ETHPORT:0..3 [,EAUTONEG=] [,EFLWCTRL=]


,PUSG=;

Command Tree:
MANAGED-ELEMENT h BSS-EQUIPMENT h BTSEP h ETHPORT h CREATE
ETHPORT
Applicability:
Phase 2 and Phase 3.
Visibility level: 2.
Command Description:
This command adds the ETHPORT to the BTSE data base.
Long Names:
NAME

Address of the managed object

EAUTONEG

enableAutoNegotiation

EFLWCTRL

enableFlowControl

PUSG

portUsage

System Responses:
Operation Completed
After command execution, a message of Changed Configuration Notification is displayed.
A further message indicates the result of the operation. An example of create command
is the following:

JOB: 39
PC Time&Date: 08.02.2008 13:20:45 +01:00
NE Time&Date: 01.01.1990 00:47:41 +00:00
USER NAME:

User_Pitt

COMMAND:

Create ETHPORT:NAME=ETHPORT:0;

SW RELEASE:

368

01-04-19-01-01-CR_08-02-08

Id:0900d805805944cc

A50016-G5100-B333-04-7619

BS-4x / 82 II / 240 / 241 / 240XL commands

ETHPORT

COMMAND RESULT: Operation successful

END OF OUTPUT FOR JOB 39


Operation Failed
None.
Application Guidelines:
Default values apply for the typical Abis Ethernet configuration.
An ETHPORT object can be only created if the ETHCON object has been created
before. Physical ports of the Ethernet switch without related ETHPORT object (except
for the monitoring port(s)) are blocked.
Example of Command Execution:
Create ETHPORT:NAME=ETHPORT:0,EAUTONEG=TRUE,EFLWCTRL=FALSE,PUSG=bscLink;

DELETE ETHPORT
DELETE ETHPORT

NAME=ETHPORT:0..3;

Command Tree:
MANAGED-ELEMENT h BSS-EQUIPMENT h BTSEP h ETHPORT h DELETE
ETHPORT
Applicability:
Phase 2 and Phase 3.
Visibility level: 2.
Command Description:
This command deletes the ETHPORT from the BTSE data base.
Long Names:
NAME

Address of the managed object

System Responses:
Operation Completed
After command execution, a message of Changed Configuration Notification is displayed.
A further message indicates the result of the operation. An example of delete command
is the following:
JOB: 39
PC Time&Date: 30.05.2008 11:00:01 +02:00

A50016-G5100-B333-04-7619

Id:0900d805805944cc

369

ETHPORT

BS-4x / 82 II / 240 / 241 / 240XL commands

NE Time&Date: 01.01.1990 00:04:34 +00:00


USER NAME:

User_Pitt

COMMAND:

Delete ETHPORT:NAME=ETHPORT:0;

SW RELEASE:

01-04-19-01-01-ZS_08-05-29

COMMAND RESULT: Operation successful

END OF OUTPUT FOR JOB 39


Operation Failed
None.
Application Guidelines:
None.
Example of Command Execution:
Delete ETHPORT:NAME=ETHPORT:0;

GET ETHPORT
GET ETHPORT

NAME=ETHPORT:0..3 [,REQATTL=ALS, AST, AVS, OST,


PRS, RELFUNCOBJ, EAUTONEG, EFLWCTRL, MTYP,
PSTAT, PUSG, SFPSERID];

Command Tree:
MANAGED-ELEMENT h BSS-EQUIPMENT h BTSEP h ETHPORT h GET
ETHPORT
Applicability:
Phase 2 and Phase 3.
Visibility level: 0.
Command Description:
This command displays the attributes of the ETHPORT.
Long Names:
NAME

Address of the managed object

REQATTL

Required attribute list

ALS

alarmStatus

AST

administrativeState

AVS

availabilityStatus

OST

operationalState

PRS

proceduralStatus

RELFUNCOBJ

370

relatedFuncObjects

Id:0900d805805944cc

A50016-G5100-B333-04-7619

BS-4x / 82 II / 240 / 241 / 240XL commands

ETHPORT

EAUTONEG

enableAutoNegotiation

EFLWCTRL

enableFlowControl

MTYP

mediaType

PSTAT

portStatus

PUSG

portUsage

SFPSERID

sfpSerialId

System Responses:
Operation Completed
A message indicates the result of the operation. An example of get command is the following:
JOB: 77
PC Time&Date: 18.04.2008 10:12:28 +02:00
NE Time&Date: 01.01.1990 00:07:58 +00:00
USER NAME:

User_Pitt

COMMAND:

Get ETHPORT:NAME=ETHPORT:0;

SW RELEASE:

01-04-19-01-07-01_08-04-03

COMMAND RESULT: Operation successful

alarmStatus = MAJOR
administrativeState = Unlocked
availabilityStatus = Degraded
operationalState = ENABLED
proceduralStatus = NULL
relatedFuncObjects = Null
enableAutoNegotiation = TRUE
enableFlowControl = FALSE
mediaType = electrical
portStatus = Null
portUsage = null
sfpSerialId = Null
END OF OUTPUT FOR JOB 77
Operation Failed
None.

A50016-G5100-B333-04-7619

Id:0900d805805944cc

371

ETHPORT

BS-4x / 82 II / 240 / 241 / 240XL commands

Application Guidelines:
None.
Example of Command Execution:
Get ETHPORT:NAME=ETHPORT:0,REQATTL=ALS&AST&AVS&OST&PRS&RELFUNCOBJ&EAUTONEG&EFLWCTRL&MTYP&PSTAT&PUSG&SPFSERID;

LOCK ETHPORT
LOCK ETHPORT

NAME=ETHPORT:0..3;

Command Tree:
MANAGED-ELEMENT h BSS-EQUIPMENT h BTSEP h ETHPORT h LOCK
ETHPORT
Applicability:
Phase 2 and Phase 3.
Visibility level: 1.
Command Description:
This command changes the administrative state of ETHPORT.
Long Names:
NAME

Address of the managed object

System Responses:
Operation Completed
The specified change of administrative state has been perfomed:
JOB: 49
PC Time&Date: 27.08.2008 14:16:31 +02:00
NE Time&Date: 27.08.2008 14:05:17 +01:00
USER NAME:

User_Pitt

COMMAND:

Lock ETHPORT:NAME=ETHPORT:0;

SW RELEASE:

01-04-19-01-11-ZT_08-08-23

COMMAND RESULT: Operation successful

administrativeState = Locked
END OF OUTPUT FOR JOB 49
Operation Failed
None.

372

Id:0900d805805944cc

A50016-G5100-B333-04-7619

BS-4x / 82 II / 240 / 241 / 240XL commands

ETHPORT

Application Guidelines:
None.
Example of Command Execution:
Lock ETHPORT:NAME=ETHPORT:0;

SET ETHPORT
SET ETHPORT

NAME=ETHPORT:0..3 [,EAUTONEG=] [,EFLWCTRL=]


[,PUSG=];

Command Tree:
MANAGED-ELEMENT h BSS-EQUIPMENT h BTSEP h ETHPORT h SET
ETHPORT
Applicability:
Phase 2 and Phase 3.
Visibility level: 2.
Command Description:
This command sets the attributes of ETHPORT to the BTSE data base.
Long Names:
NAME

Address of the managed object

EAUTONEG

enableAutoNegotiation

EFLWCTRL

enableFlowControl

PUSG

portUsage

System Responses:
Operation Completed
After command execution, a message of Changed Configuration Notification is displayed.
A further message indicates the result of the operation. An example of set command is
the following:
JOB: 35
PC Time&Date: 30.05.2008 10:59:41 +02:00
NE Time&Date: 01.01.1990 00:04:14 +00:00
USER NAME:

User_Pitt

COMMAND:

Set ETHPORT:NAME=ETHPORT:0,PUSG=null;

SW RELEASE:

01-04-19-01-01-ZS_08-05-29

COMMAND RESULT: Operation successful

A50016-G5100-B333-04-7619

Id:0900d805805944cc

373

ETHPORT

BS-4x / 82 II / 240 / 241 / 240XL commands

portUsage = null
END OF OUTPUT FOR JOB 35
Operation Failed
None.
Application Guidelines:
None.
Example of Command Execution:
Set ETHPORT:NAME=ETHPORT:0,EAUTONEG=TRUE,EFLWCTRL=FALSE,PUSG=null;

UNLOCK ETHPORT
UNLOCK ETHPORT

NAME=ETHPORT:0..3;

Command Tree:
MANAGED-ELEMENT h BSS-EQUIPMENT h BTSEP h ETHPORT h UNLOCK
ETHPORT
Applicability:
Phase 2 and Phase 3.
Visibility level: 1.
Command Description:
This command changes the administrative state of ETHPORT.
Long Names:
NAME

Address of the managed object

System Responses:
Operation Completed
The specified change of administrative state has been perfomed:
JOB: 52
PC Time&Date: 27.08.2008 14:16:56 +02:00
NE Time&Date: 27.08.2008 14:05:42 +01:00
USER NAME:

User_Pitt

COMMAND:

Unlock ETHPORT:NAME=ETHPORT:0;

SW RELEASE:

01-04-19-01-11-ZT_08-08-23

COMMAND RESULT: Operation successful

374

Id:0900d805805944cc

A50016-G5100-B333-04-7619

BS-4x / 82 II / 240 / 241 / 240XL commands

ETHPORT

administrativeState = Unlocked
END OF OUTPUT FOR JOB 52
Operation Failed
None.
Application Guidelines:
None.
Example of Command Execution:
Unlock ETHPORT:NAME=ETHPORT:0;

A50016-G5100-B333-04-7619

Id:0900d805805944cc

375

F6DCTMA

BS-4x / 82 II / 240 / 241 / 240XL commands

F6DCTMA
This object represents the TMA power supply of one antenna port. The functionality of
the object is identical to the DUDCTMA object of an MFDUAMCO.

CREATE F6DCTMA
CREATE F6DCTMA

NAME=RACK:0..7/F6DCTMA:0..3;

Command Tree:
MANAGED-ELEMENT h BSS-EQUIPMENT h BTSEP h RACK h F6DCTMA h
CREATE F6DCTMA
Applicability:
Phase 2 and Phase 3.
Visibility level: 2.
Command Description:
This command adds the F6DCTMA to the BTSE data base. The creation of the
F6DCTMA object implicitly switches on the TMA power supply. The power supply may
be also switched on via DIP switch.
Long Names:
NAME

Address of the managed object

System Responses:
Operation Completed
After command execution, a message of Changed Configuration Notification is displayed. A further message indicates the result of the operation. An example of create
command is the following:
JOB: 288
PC Time&Date: 17.10.2008 09:24:24 +02:00
NE Time&Date: 01.01.1990 19:05:33 +00:00
USER NAME:

User_NSN

COMMAND:

Create F6DCTMA:NAME=RACK:0/F6DCTMA:0;

SW RELEASE:

01-04-19-01-11-07_08-10-16

COMMAND RESULT: Operation successful


END OF OUTPUT FOR JOB 288
Operation Failed
The specified Object has not been created. In addition to the general NACK causes, a
specific NACK cause, which indicates that the command is inconsistent with the
physical configuration, is possible. An example is the following:

376

Id:0900d8058059598c

A50016-G5100-B333-04-7619

BS-4x / 82 II / 240 / 241 / 240XL commands

F6DCTMA

JOB: 34
PC Time&Date: 25.09.2008 14:46:58 +02:00
NE Time&Date: 02.01.1990 00:03:39 +00:00
USER NAME:

User_NSN

COMMAND:

Create F6DCTMA:NAME=RACK:0/F6DCTMA:0;

SW RELEASE:

03-04-19-01-11-05_08-09-24

COMMAND RESULT: Operation failed

Creation out of sequence (-162)


END OF OUTPUT FOR JOB 34
Application Guidelines:
None.
Example of Command Execution:
Create F6DCTMA:NAME=RACK:0/F6DCTMA:0;

DELETE F6DCTMA
DELETE F6DCTMA

NAME=RACK:0..7/F6DCTMA:0..3;

Command Tree:
MANAGED-ELEMENT h BSS-EQUIPMENT h BTSEP h RACK h F6DCTMA h
DELETE F6DCTMA
Applicability:
Phase 2 and Phase 3.
Visibility level: 2.
Command Description:
This command deletes the F6DCTMA from the BTSE data base.
Long Names:
NAME

Address of the managed object

System Responses:
Operation Completed
After command execution, a message of Changed Configuration Notification is displayed. A further message indicates the result of the operation. An example of delete
command is the following:

A50016-G5100-B333-04-7619

Id:0900d8058059598c

377

F6DCTMA

BS-4x / 82 II / 240 / 241 / 240XL commands

JOB: 59
PC Time&Date: 17.10.2008 09:05:13 +02:00
NE Time&Date: 01.01.1990 18:46:22 +00:00
USER NAME:

User_NSN

COMMAND:

Delete F6DCTMA:NAME=RACK:0/F6DCTMA:0;

SW RELEASE:

01-04-19-01-11-07_08-10-16

COMMAND RESULT: Operation successful

END OF OUTPUT FOR JOB 59


Operation Failed
The specified Object has not been deleted. In addition to the general NACK causes, a
specific NACK cause, which indicates that the command is inconsistent with the
physical configuration, is possible. An example is the following:
JOB: 137
PC Time&Date: 24.09.2008 15:06:31 +02:00
NE Time&Date: 01.01.1990 00:23:14 +00:00
USER NAME:

User_NSN

COMMAND:

Delete F6DCTMA:NAME=RACK:0/F6DCTMA:0;

SW RELEASE:

03-04-19-01-11-05_08-09-24

COMMAND RESULT: Operation failed

MO or MOT not locked (-151)


END OF OUTPUT FOR JOB 137

Application Guidelines:
None.
Example of Command Execution:
Delete F6DCTMA:NAME=RACK:0/F6DCTMA:0;

378

Id:0900d8058059598c

A50016-G5100-B333-04-7619

BS-4x / 82 II / 240 / 241 / 240XL commands

F6DCTMA

GET F6DCTMA
GET F6DCTMA

NAME=RACK:0..7/F6DCTMA:0..3 [,REQATTL=ALS, AST,


AVS, OST, PRS, RELFUNCOBJ];

Command Tree:
MANAGED-ELEMENT h BSS-EQUIPMENT h BTSEP h RACK h F6DCTMA h
GET F6DCTMA
Applicability:
Phase 2 and Phase 3.
Visibility level: 0.
Command Description:
This command displays the attributes of the F6DCTMA.
Long Names:
NAME

Address of the managed object

REQATTL

Required attribute list

ALS

alarmStatus

AST

administrativeState

AVS

availabilityStatus

OST

operationalState

PRS

proceduralStatus

RELFUNCOBJ

relatedFuncObjects

System Responses:
Operation Completed
A message indicates the result of the operation. An example of get command is the following:
JOB: 140
PC Time&Date: 16.09.2008 15:59:02 +02:00
NE Time&Date: 01.01.1990 00:19:44 +00:00
USER NAME:

User_NSN

COMMAND:

Get F6DCTMA:NAME=RACK:0/F6DCTMA:0;

SW RELEASE:

01-04-19-01-12-MB_08-09-16

COMMAND RESULT: Operation successful

alarmStatus = CLEARED
administrativeState = Unlocked

A50016-G5100-B333-04-7619

Id:0900d8058059598c

379

F6DCTMA

BS-4x / 82 II / 240 / 241 / 240XL commands

availabilityStatus = NotInstalled
operationalState = DISABLED
proceduralStatus = NULL
relatedFuncObjects = Null
END OF OUTPUT FOR JOB 140
Operation Failed
None.
Application Guidelines:
None.
Example of Command Execution:
Get F6DCTMA:NAME=RACK:0/F6DCTMA:0,
REQATTL=ALS&AST&AVS&OST&PRS&&RELFUNCOBJ;

GETTEST F6DCTMA
GETTEST F6DCTMA

NAME=RACK:0..7/F6DCTMA:0..3;

Command Tree:
MANAGED-ELEMENT h BSS-EQUIPMENT h BTSEP h RACK h F6DCTMA h
GETTEST F6DCTMA
Applicability:
Phase 2 and Phase 3.
Visibility level: 0.
Command Description:
This command displays the attributes of the object test.
Long Names:
NAME

Address of the managed object

REQATTL

Required attribute list

System Responses:
Operation Completed
A message indicates the result of the operation. An example of gettest command is the
following:
JOB: 173
PC Time&Date: 28.10.2008 16:31:01 +01:00
NE Time&Date: 01.01.1990 00:21:30 +00:00
USER NAME:

380

User_NSN

Id:0900d8058059598c

A50016-G5100-B333-04-7619

BS-4x / 82 II / 240 / 241 / 240XL commands

COMMAND:

F6DCTMA

Gettest F6DCTMA:NAME=RACK:0/F6DCTMA:0;

SW RELEASE:

01-04-19-01-11-08_08-10-17

COMMAND RESULT: Operation successful


END OF OUTPUT FOR JOB 173
Operation Failed
The specified action cannot be performed. In addition to the general NACK causes, a
specific NACK cause, which indicates that the command is inconsistent with the
physical configuration, is possible. An example is the following:
JOB: 48
PC Time&Date: 17.10.2008 09:04:29 +02:00
NE Time&Date: 01.01.1990 18:45:38 +00:00
USER NAME:

User_NSN

COMMAND:

Gettest F6DCTMA:NAME=RACK:0/F6DCTMA:0;

SW RELEASE:

01-04-19-01-11-07_08-10-16

COMMAND RESULT: Operation failed

MOT = RACK:0/F6DCTMA:0
Object instance unknown or not allowed (-9)
END OF OUTPUT FOR JOB 48
Application Guidelines:
None.
Example of Command Execution:
Gettest F6DCTMA:NAME=RACK:0/F6DCTMA:0;

LOCK F6DCTMA
LOCK F6DCTMA

NAME=RACK:0..7/F6DCTMA:0..3;

Command Tree:
MANAGED-ELEMENT h BSS-EQUIPMENT h BTSEP h RACK h F6DCTMA h
LOCK F6DCTMA
Applicability:
Phase 2 and Phase 3.
Visibility level: 1.

A50016-G5100-B333-04-7619

Id:0900d8058059598c

381

F6DCTMA

BS-4x / 82 II / 240 / 241 / 240XL commands

Command Description:
This command changes the administrative state of F6DCTMA.
Long Names:
NAME

Address of the managed object

System Responses:
Operation Completed
The specified change of administrative state has been perfomed:
JOB: 40
PC Time&Date: 17.10.2008 09:04:19 +02:00
NE Time&Date: 01.01.1990 18:45:28 +00:00
USER NAME:

User_NSN

COMMAND:

Lock F6DCTMA:NAME=RACK:0/F6DCTMA:0;

SW RELEASE:

01-04-19-01-11-07_08-10-16

COMMAND RESULT: Operation successful

administrativeState = Locked
END OF OUTPUT FOR JOB 40
Operation Failed
None.
Application Guidelines:
None.
Example of Command Execution:
Lock F6DCTMA:NAME=RACK:0/F6DCTMA:1;

PERFTEST F6DCTMA
PERFTEST F6DCTMA

NAME=RACK:0..7/F6DCTMA:0..3;

Command Tree:
MANAGED-ELEMENT h BSS-EQUIPMENT h BTSEP h RACK h F6DCTMA h
PERFTEST F6DCTMA
Applicability:
Phase 2 and Phase 3.
Visibility level: 1.

382

Id:0900d8058059598c

A50016-G5100-B333-04-7619

BS-4x / 82 II / 240 / 241 / 240XL commands

F6DCTMA

Command Description:
This command is used to start an asynchronous test in the object.
Long Names:
NAME

Address of the managed object

System Responses:
Operation Completed
Test configuration has been set and the specified test has been started. An example is
the following:
JOB: 43
PC Time&Date: 17.10.2008 09:04:27 +02:00
NE Time&Date: 01.01.1990 18:45:36 +00:00
USER NAME:

User_NSN

COMMAND:

Perftest F6DCTMA:NAME=RACK:0/F6DCTMA:0;

SW RELEASE:

01-04-19-01-11-07_08-10-16

COMMAND RESULT: Operation successful

MOT = RACK:0/F6DCTMA:0
tO = BTSETEST:1
END OF OUTPUT FOR JOB 43
Operation Failed
The specified test cannot be performed. In addition to the general NACK causes, a
specific NACK cause, which indicates that the command is inconsistent with the
physical configuration, is possible. An example is the following:
JOB: 140
PC Time&Date: 24.09.2008 15:06:41 +02:00
NE Time&Date: 01.01.1990 00:23:24 +00:00
USER NAME:

User_NSN

COMMAND:

Perftest F6DCTMA:NAME=RACK:0/F6DCTMA:0;

SW RELEASE:

03-04-19-01-11-05_08-09-24

COMMAND RESULT: Operation failed

A50016-G5100-B333-04-7619

Id:0900d8058059598c

383

F6DCTMA

BS-4x / 82 II / 240 / 241 / 240XL commands

MOT = RACK:0/F6DCTMA:0
Physical configuration cannot be performed (-30)
END OF OUTPUT FOR JOB 140
Application Guidelines:
None.
Example of Command Execution:
Perftest F6DCTMA:NAME=RACK:0/F6DCTMA:0;

STOPTEST F6DCTMA
STOPTEST F6DCTMA

NAME=RACK:0..7/F6DCTMA:0..3;

Command Tree:
MANAGED-ELEMENT h BSS-EQUIPMENT h BTSEP h RACK h F6DCTMA h
STOPTEST F6DCTMA
Applicability:
Phase 2 and Phase 3.
Visibility level: 1.
Command Description:
This command is used to stop a diagnostic previously started.
Long Names:
NAME

Address of the managed object

System Responses:
Operation Completed
Test has been stopped. The System Responses will not be addressed to the MOT but
to the object.

Result TEST:
name =

TEST:<n>

testOutcome =

inconclusive

mOts =

It is the identifier of the hardware object under test.

testTermination =

Cancel

executedPhases
phaseId =
...
.

384

It represents the list of the executed test phases; the


list is not shown for test in the waiting list (queued).

Id:0900d8058059598c

A50016-G5100-B333-04-7619

BS-4x / 82 II / 240 / 241 / 240XL commands

F6DCTMA

failedPhases
phaseId =

It represents the list of the failed test phase;

phaseId =

additional information is provided for each phase.

....
skippedPhases
phaseId =

It represents the list of the skipped phases;the list is


not shown for test in the waiting list (queued).

phaseId =
Operation Failed

The specified test cannot be stopped. In addition to the general NACK causes, a specific
NACK cause, which indicates that the command is inconsistent with the physical configuration, is possible. An example is the following:
JOB: 55
PC Time&Date: 17.10.2008 09:04:59 +02:00
NE Time&Date: 01.01.1990 18:46:08 +00:00
USER NAME:

User_NSN

COMMAND:

Stoptest F6DCTMA:NAME=RACK:0/F6DCTMA:0;

SW RELEASE:

01-04-19-01-11-07_08-10-16

COMMAND RESULT: Operation failed

MOT = RACK:0/F6DCTMA:0
Object instance unknown or not allowed (-9)
END OF OUTPUT FOR JOB 55
Application Guidelines:
None.
Example of Command Execution:
Stoptest F6DCTMA:NAME=RACK:0/F6DCTMA:0;

UNLOCK F6DCTMA
UNLOCK F6DCTMA

NAME=RACK:0..7/F6DCTMA:0..3;

Command Tree:
MANAGED-ELEMENT h BSS-EQUIPMENT h BTSEP h RACK h F6DCTMA h
UNLOCK F6DCTMA

A50016-G5100-B333-04-7619

Id:0900d8058059598c

385

F6DCTMA

BS-4x / 82 II / 240 / 241 / 240XL commands

Applicability:
Phase 2 and Phase 3.
Visibility level: 1.
Command Description:
This command changes the administrative state of F6DCTMA.
Long Names:
NAME

Address of the managed object

System Responses:
Operation Completed
The specified change of administrative state has been perfomed:
JOB: 56
PC Time&Date: 17.10.2008 09:05:06 +02:00
NE Time&Date: 01.01.1990 18:46:15 +00:00
USER NAME:

User_NSN

COMMAND:

Unlock F6DCTMA:NAME=RACK:0/F6DCTMA:0;

SW RELEASE:

01-04-19-01-11-07_08-10-16

COMMAND RESULT: Operation successful

administrativeState = Unlocked
END OF OUTPUT FOR JOB 56
Operation Failed
None.
Application Guidelines:
None.
Example of Command Execution:
Unlock F6DCTMA:NAME=RACK:0/F6DCTMA:0;

386

Id:0900d8058059598c

A50016-G5100-B333-04-7619

BS-4x / 82 II / 240 / 241 / 240XL commands

F6LNA

F6LNA
The F6LNA object integrates hw functionality both of DILNA and DULNA objects.

CREATE F6LNA
CREATE F6LNA

NAME=RACK:0..7/F6LNA:0..3 ,CELLNO= [,SCELLNO=]


[,GNADB=] [,LNAPRED=] ,WDLNA= [,LNAMDB=];

Command Tree:
MANAGED-ELEMENT h BSS-EQUIPMENT h BTSEP h RACK h F6LNA h
CREATE F6LNA
Applicability:
Phase 2 and Phase 3.
Visibility level: 2.
Command Description:
This command adds the F6LNA to the BTSE data base.
Long Names:
NAME

Address of the managed object

CELLNO

cellNumber

SCELLNO

secondCellNumber

GNADB

gainAdjustDb

LNAPRED

lnaPredecessor

WDLNA

wiringDataLna

LNAMDB

lnaModeDb

System Responses:
Operation Completed
After command execution, a message of Changed Configuration Notification is displayed. A further message indicates the result of the operation. An example of create
command is the following:
JOB: 71
PC Time&Date: 26.09.2008 13:12:42 +02:00
NE Time&Date: 26.09.2008 10:20:00 +01:00
USER NAME:

User_NSN

COMMAND:
Create
F6LNA:NAME=RACK:0/F6LNA:1,CELLNO=1,WDLNA=FCUMAIN1N;
SW RELEASE:

03-04-19-01-11-05_08-09-24

COMMAND RESULT: Operation successful

A50016-G5100-B333-04-7619

Id:0900d8058059598e

387

F6LNA

BS-4x / 82 II / 240 / 241 / 240XL commands

cellNumber = 1
wiringDataLna = FCUMAIN1N

END OF OUTPUT FOR JOB 71


Operation Failed
The specified Object has not been created. In addition to the general NACK causes, a
specific NACK cause, which indicates that the command is inconsistent with the
physical configuration, is possible. An example is the following:
JOB: 9
PC Time&Date: 25.09.2008 14:46:05 +02:00
NE Time&Date: 02.01.1990 00:02:46 +00:00
USER NAME:

User_NSN

COMMAND:
Create
F6LNA:NAME=RACK:0/F6LNA:1,CELLNO=0,GNADB=N_00,LNAPRED=TMA(RACK
0-TMA1),WDLNA=CU0D;
SW RELEASE:

03-04-19-01-11-05_08-09-24

COMMAND RESULT: Operation failed

cellNumber = 0
gainAdjustDb = N_00
lnaPredecessor =
predType =
TMA
predRack = RACK0
predNo = TMA1
wiringDataLna = CU0D
message cannot be performed (-17)
END OF OUTPUT FOR JOB 9
Application Guidelines:
F6LNA creation attempts with more than 6 wiring paths specified in wiringDataLna
attribute are rejected by BTS SW.

388

Id:0900d8058059598e

A50016-G5100-B333-04-7619

BS-4x / 82 II / 240 / 241 / 240XL commands

F6LNA

Example of Command Execution:


Create F6LNA:NAME=RACK:0/F6LNA:1,CELLNO=1,WDLNA=FCUMAIN1N

DELETE F6LNA
DELETE F6LNA

NAME=RACK:0..7/F6LNA:0..3;

Command Tree:
MANAGED-ELEMENT h BSS-EQUIPMENT h BTSEP h RACK h F6LNA h
DELETE F6LNA
Applicability:
Phase 2 and Phase 3.
Visibility level: 2.
Command Description:
This command deletes the F6LNA from the BTSE data base.
Long Names:
NAME

Address of the managed object

System Responses:
Operation Completed
After command execution, a message of Changed Configuration Notification is displayed. A further message indicates the result of the operation. An example of delete
command is the following:
JOB: 29
PC Time&Date: 25.09.2008 14:46:53 +02:00
NE Time&Date: 02.01.1990 00:03:34 +00:00
USER NAME:

User_NSN

COMMAND:

Delete F6LNA:NAME=RACK:0/F6LNA:0;

SW RELEASE:

03-04-19-01-11-05_08-09-24

COMMAND RESULT: Operation successful

END OF OUTPUT FOR JOB 29


Operation Failed
The specified Object has not been deleted. Additionally to the general NACK causes, a
specific NACK cause, meaning that the command is inconsistent with physical configuration, is possible. An example is the following:

A50016-G5100-B333-04-7619

Id:0900d8058059598e

389

F6LNA

BS-4x / 82 II / 240 / 241 / 240XL commands

JOB: 12
PC Time&Date: 25.09.2008 14:46:19 +02:00
NE Time&Date: 02.01.1990 00:03:00 +00:00
USER NAME:

User_NSN

COMMAND:

Delete F6LNA:NAME=RACK:0/F6LNA:0;

SW RELEASE:

03-04-19-01-11-05_08-09-24

COMMAND RESULT: Operation failed

MO or MOT not locked (-151)


END OF OUTPUT FOR JOB 12
Application Guidelines:
None.
Example of Command Execution:
Delete F6LNA:NAME=RACK:0/F6LNA:0;

GET F6LNA
GET F6LNA

NAME=RACK:0..7/F6LNA:0..3 [,REQATTL=ALS, AST,


OST, PRS, AVS, CELLNO, SCELLNO, GNA, GNADB,
LNAPRED, WDLNA, LNAMDB, LNAMODE, RELFUNCOBJ];

Command Tree:
MANAGED-ELEMENT h BSS-EQUIPMENT h BTSEP h RACK h F6LNA h
GET F6LNA
Applicability:
Phase 2 and Phase 3.
Visibility level: 0.
Command Description:
This command displays the attributes of the F6LNA.
Long Names:

390

NAME

Address of the managed object

REQATTL

Required attribute list

ALS

alarmStatus

AST

administrativeState

OST

operationalState

Id:0900d8058059598e

A50016-G5100-B333-04-7619

BS-4x / 82 II / 240 / 241 / 240XL commands

F6LNA

PRS

proceduralStatus

AVS

availabilityStatus

CELLNO

cellNumber

SCELLNO

secondCellNumber

GNA

gainAdjust(dB)

GNADB

gainAdjustDb

LNAPRED

lnaPredecessor

WDLNA

wiringDataLna

LNAMDB

lnaModeDb

LNAMODE

lnaMode

RELFUNCOBJ

relatedFuncObjects

System Responses:
Operation Completed
A message indicates the result of the operation. An example of get command is the following:
JOB: 60
PC Time&Date: 17.10.2008 09:05:21 +02:00
NE Time&Date: 01.01.1990 18:46:30 +00:00
USER NAME:

User_NSN

COMMAND:

Get F6LNA:NAME=RACK:0/F6LNA:0;

SW RELEASE:

01-04-19-01-11-07_08-10-16

COMMAND RESULT: Operation successful

alarmStatus = CLEARED
administrativeState = Unlocked
operationalState = ENABLED
proceduralStatus = NULL
availabilityStatus = NULL
cellNumber = 0
secondCellNumber = NotUsed
gainAdjust(dB) = N_00
gainAdjustDb = DIP
lnaPredecessor = Null
wiringDataLna = CU0N & CU1N & CU2N & CU3N
lnaModeDb = DIP

A50016-G5100-B333-04-7619

Id:0900d8058059598e

391

F6LNA

BS-4x / 82 II / 240 / 241 / 240XL commands

lnaMode = AMCO_MODE
relatedFuncObjects = Null
END OF OUTPUT FOR JOB 60
Operation Failed
None.
Application Guidelines:
None.
Example of Command Execution:
Get F6LNA:NAME=RACK:0/F6LNA:0;REQATTL= ALS& AST& OST& PRS& AVS&
CELLNO& SCELLNO& GNA& GNADB&LNAPRED& WDLNA& LNAMDB&
LNAMODE& RELFUNCOBJ;

GETTEST F6LNA
GETTEST F6LNA

NAME=RACK:0..7/F6LNA:0..3;

Command Tree:
MANAGED-ELEMENT h BSS-EQUIPMENT h BTSEP h RACK h F6LNA h
GETTEST F6LNA
Applicability:
Phase 2 and Phase 3.
Visibility level: 0.
Command Description:
This command displays the attributes of the object test.
Long Names:
NAME

Address of the managed object

REQATTL

Required attribute list

System Responses:
Operation Completed
A message indicates the result of the operation. An example of gettest command is the
following:
JOB: 273
PC Time&Date: 17.10.2008 09:21:19 +02:00
NE Time&Date: 01.01.1990 19:02:28 +00:00

392

USER NAME:

User_NSN

COMMAND:

Gettest F6LNA:NAME=RACK:0/F6LNA:1;

Id:0900d8058059598e

A50016-G5100-B333-04-7619

BS-4x / 82 II / 240 / 241 / 240XL commands

SW RELEASE:

F6LNA

01-04-19-01-11-07_08-10-16

COMMAND RESULT: Operation successful


END OF OUTPUT FOR JOB 273
Operation Failed
The GETTEST command has not been successfully executed. A general NACK will
indicate possible errors or a specific NACK strictly related to the single command is possible. An example of specific NACK is the following:
JOB: 69
PC Time&Date: 17.10.2008 09:05:40 +02:00
NE Time&Date: 01.01.1990 18:46:49 +00:00
USER NAME:

User_NSN

COMMAND:

Gettest F6LNA:NAME=RACK:0/F6LNA:0;

SW RELEASE:

01-04-19-01-11-07_08-10-16

COMMAND RESULT: Operation failed

MOT = RACK:0/F6LNA:0
Object instance unknown or not allowed (-9)
END OF OUTPUT FOR JOB 69
Application Guidelines:
None.
Example of Command Execution:
Gettest F6LNA:NAME=RACK:0/F6LNA:0;

LOCK F6LNA
LOCK F6LNA

NAME=RACK:0..7/F6LNA:0..3;

Command Tree:
MANAGED-ELEMENT h BSS-EQUIPMENT h BTSEP h RACK h F6LNA h
LOCK F6LNA
Applicability:
Phase 2 and Phase 3.
Visibility level: 1.

A50016-G5100-B333-04-7619

Id:0900d8058059598e

393

F6LNA

BS-4x / 82 II / 240 / 241 / 240XL commands

Command Description:
This command changes the administrative state of F6LNA.
Long Names:
NAME

Address of the managed object

System Responses:
Operation Completed
After command execution, a message of Changed Configuration Notification is displayed. A further message indicates the result of the operation. An example of lock
command is the following:
JOB: 113
PC Time&Date: 28.10.2008 16:26:55 +01:00
NE Time&Date: 01.01.1990 00:17:24 +00:00
USER NAME:

User_NSN

COMMAND:

Lock F6LNA:NAME=RACK:0/F6LNA:0;

SW RELEASE:

01-04-19-01-11-08_08-10-17

COMMAND RESULT: Operation successful

administrativeState = Locked
END OF OUTPUT FOR JOB 113
Operation Failed
None.
Application Guidelines:
None.
Example of Command Execution:
Lock F6LNA:NAME=RACK:0/F6LNA:0

PERFTEST F6LNA
PERFTEST F6LNA

NAME=RACK:0..7/F6LNA:0..3;

Command Tree:
MANAGED-ELEMENT h BSS-EQUIPMENT h BTSEP h RACK h F6LNA h
PERFTEST F6LNA

394

Id:0900d8058059598e

A50016-G5100-B333-04-7619

BS-4x / 82 II / 240 / 241 / 240XL commands

F6LNA

Applicability:
Phase 2 and Phase 3.
Visibility level: 1.
Command Description:
This command is used to start an asynchronous test in the object.
Long Names:
NAME

Address of the managed object

System Responses:
Operation Completed
After command execution, a message of Changed Configuration Notification is displayed. A further message indicates the result of the operation. An example of perftest
command is the following:
JOB: 13
PC Time&Date: 26.09.2008 13:05:27 +02:00
NE Time&Date: 26.09.2008 10:12:45 +01:00
USER NAME:

User_NSN

COMMAND:

Perftest F6LNA:NAME=RACK:0/F6LNA:0;

SW RELEASE:

03-04-19-01-11-05_08-09-24

COMMAND RESULT: Operation successful

MOT = RACK:0/F6LNA:0
tO = BTSETEST:7
END OF OUTPUT FOR JOB 13
Operation Failed
The specified test cannot be performed. In addition to the general NACK causes, a
specific NACK cause, which indicates that the command is inconsistent with the
physical configuration, is possible. An example is the following:
JOB: 145
PC Time&Date: 16.09.2008 16:01:13 +02:00
NE Time&Date: 01.01.1990 00:21:55 +00:00
USER NAME:

A50016-G5100-B333-04-7619

User_NSN

Id:0900d8058059598e

395

F6LNA

BS-4x / 82 II / 240 / 241 / 240XL commands

COMMAND:

Perftest F6LNA:NAME=RACK:0/F6LNA:0;

SW RELEASE:

01-04-19-01-12-MB_08-09-16

COMMAND RESULT: Operation failed

MOT = RACK:0/F6LNA:0
MO or MOT not locked (-151)
END OF OUTPUT FOR JOB 145
Application Guidelines:
None.
Example of Command Execution:
Perftest F6LNA:NAME=RACK:0/F6LNA:0;

SET F6LNA
SET F6LNA

NAME=RACK:0..7/F6LNA:0..3 [,SCELLNO=] [,GNADB=]


[,WDLNA=] [,LNAMDB=];

Command Tree:
MANAGED-ELEMENT h BSS-EQUIPMENT h BTSEP h RACK h F6LNA h
SET F6LNA
Applicability:
Phase 2 and Phase 3.
Visibility level: 2.
Command Description:
This command sets the attributes of F6LNA.
Long Names:
NAME

Address of the managed object

SCELLNO

secondCellNumber

GNADB

gainAdjustDb

WDLNA

wiringDataLna

LNAMDB

lnaModeDb

System Responses:
Operation Completed
After command execution, a message of Changed Attribute Event Report is displayed.
A further message indicates the result of the operation. An example of set command is
the following:
JOB: 219

396

Id:0900d8058059598e

A50016-G5100-B333-04-7619

BS-4x / 82 II / 240 / 241 / 240XL commands

F6LNA

PC Time&Date: 24.09.2008 14:37:37 +02:00


NE Time&Date: 24.09.2008 10:46:11 +00:00
USER NAME:

User_NSN

COMMAND:

Set F6LNA:NAME=RACK:0/F6LNA:0,GNADB=N_00;

SW RELEASE:

03-04-19-01-11-05_08-09-24

COMMAND RESULT: Operation successful

gainAdjustDb = N_00

END OF OUTPUT FOR JOB 219


Operation Failed
The specified Object has not been set. In addition to the general NACK causes, a
specific NACK cause, which indicates that the command is inconsistent with the
physical configuration, is possible. An example is the following:
JOB: 216
PC Time&Date: 24.09.2008 14:37:13 +02:00
NE Time&Date: 24.09.2008 10:45:47 +00:00
USER NAME:

User_NSN

COMMAND:
Set
F6LNA:NAME=RACK:0/F6LNA:0,GNADB=N_11,LNAMDB=AMCO_MODE,SCELLNO
=N_00,WDLNA=CU0D&CU1D;
SW RELEASE:

03-04-19-01-11-05_08-09-24

COMMAND RESULT: Operation failed

secondCellNumber = N_00
gainAdjustDb = N_11
wiringDataLna = CU0D & CU1D
lnaModeDb = AMCO_MODE
message cannot be performed (-17)
END OF OUTPUT FOR JOB 216

A50016-G5100-B333-04-7619

Id:0900d8058059598e

397

F6LNA

BS-4x / 82 II / 240 / 241 / 240XL commands

Application Guidelines:
None.
Example of Command Execution:
Set F6LNA:NAME=RACK:0/F6LNA:0,GNADB=N_00;

STOPTEST F6LNA
STOPTEST F6LNA

NAME=RACK:0..7/F6LNA:0..3;

Command Tree:
MANAGED-ELEMENT h BSS-EQUIPMENT h BTSEP h RACK h F6LNA h
STOPTEST F6LNA
Applicability:
Phase 2 and Phase 3.
Visibility level: 1.
Command Description:
This command is used to stop a diagnostic previously started.
Long Names:
NAME

Address of the managed object

System Responses:
Operation Completed
Test has been stopped. The System Responses will not be addressed to the MOT but
to the object.

Result TEST:
name =

TEST:<n>

testOutcome =

inconclusive

mOts =

It is the identifier of the hardware object under test.

testTermination =

Cancel

executedPhases
phaseId =
...
.

It represents the list of the executed test phases; the


list is not shown for test in the waiting list (queued).

failedPhases
phaseId =

It represents the list of the failed test phase;

phaseId =

additional information is provided for each phase.

....
skippedPhases

398

Id:0900d8058059598e

A50016-G5100-B333-04-7619

BS-4x / 82 II / 240 / 241 / 240XL commands

F6LNA

phaseId =

It represents the list of the skipped phases;the list is


not shown for test in the waiting list (queued).

phaseId =
Operation Failed

The specified test cannot be stopped. In addition to the general NACK causes, a specific
NACK cause, which indicates that the command is inconsistent with the physical configuration, is possible. An example is the following:
JOB: 274
PC Time&Date: 17.10.2008 09:21:25 +02:00
NE Time&Date: 01.01.1990 19:02:34 +00:00
USER NAME:

User_NSN

COMMAND:

Stoptest F6LNA:NAME=RACK:0/F6LNA:1;

SW RELEASE:

01-04-19-01-11-07_08-10-16

COMMAND RESULT: Operation failed

MOT = RACK:0/F6LNA:1
Object instance unknown or not allowed (-9)
END OF OUTPUT FOR JOB 274
Application Guidelines:
None.
Example of Command Execution:
Stoptest F6LNA:NAME=RACK:0/F6LNA:1;

UNLOCK F6LNA
UNLOCK F6LNA

NAME=RACK:0..7/F6LNA:0..3;

Command Tree:
MANAGED-ELEMENT h BSS-EQUIPMENT h BTSEP h RACK h F6LNA h
UNLOCK F6LNA
Applicability:
Phase 2 and Phase 3.
Visibility level: 1.
Command Description:
This command changes the administrative state of F6LNA.

A50016-G5100-B333-04-7619

Id:0900d8058059598e

399

F6LNA

BS-4x / 82 II / 240 / 241 / 240XL commands

Long Names:
NAME

Address of the managed object

System Responses:
Operation Completed
After command execution, a message of Changed Configuration Notification is displayed. A further message indicates the result of the operation. An example of unlock
command is the following:
JOB: 18
PC Time&Date: 26.09.2008 13:06:03 +02:00
NE Time&Date: 26.09.2008 10:13:21 +01:00
USER NAME:

User_NSN

COMMAND:

Unlock F6LNA:NAME=RACK:0/F6LNA:0;

SW RELEASE:

03-04-19-01-11-05_08-09-24

COMMAND RESULT: Operation successful

administrativeState = Unlocked
END OF OUTPUT FOR JOB 18
Operation Failed
None.
Application Guidelines:
None.
Example of Command Execution:
Unlock F6LNA:NAME=RACK:0/F6LNA:0;

400

Id:0900d8058059598e

A50016-G5100-B333-04-7619

BS-4x / 82 II / 240 / 241 / 240XL commands

F6TNFP

F6TNFP
The object provides functionality to configure and supervise the turnable narrowband
filter of one TX path.

CREATE F6TNFP
CREATE F6TNFP

NAME=RACK:0..7/F6TNFP:0..11 ,WDFTNFP=;

Command Tree:
MANAGED-ELEMENT h BSS-EQUIPMENT h BTSEP h RACK h F6TNFP h
CREATE F6TNFP
Applicability:
Phase 2 and Phase 3.
Visibility level: 2.
Command Description:
This command adds the F6TNFP to the BTSE data base.
Long Names:
NAME

Address of the managed object

WDFTNFP

wiringDataFtnfp

System Responses:
Operation Completed
After command execution, a message of Changed Configuration Notification is displayed. A further message indicates the result of the operation. An example of create
command is the following:
JOB: 201
PC Time&Date: 17.10.2008 09:13:37 +02:00
NE Time&Date: 01.01.1990 18:54:46 +00:00
USER NAME:

User_q

COMMAND:
FVSWRP0;

Create F6TNFP:NAME=RACK:0/F6TNFP:0,WDFTNFP=CU0-

SW RELEASE:

01-04-19-01-11-07_08-10-16

COMMAND RESULT: Operation successful

wiringDataFtnfp =
CUWiring = CU0
FVSWRPWiring = FVSWRP0

A50016-G5100-B333-04-7619

Id:0900d80580595990

401

F6TNFP

BS-4x / 82 II / 240 / 241 / 240XL commands

END OF OUTPUT FOR JOB 201


Operation Failed
The specified Object has not been created. In addition to the general NACK causes, a
specific NACK cause, which indicates that the command is inconsistent with the
physical configuration, is possible. An example is the following:
JOB: 322
PC Time&Date: 17.09.2008 16:20:44 +02:00
NE Time&Date: 17.09.2008 13:29:17 +01:00
USER NAME:

User_q

COMMAND:
FVSWRP1;

Create F6TNFP:NAME=RACK:0/F6TNFP:0,WDFTNFP=CU2-

SW RELEASE:

01-04-19-01-12-MB_08-09-12

COMMAND RESULT: Operation failed

wiringDataFtnfp =
CUWiring = CU2
FVSWRPWiring = FVSWRP1
message cannot be performed (-17)
END OF OUTPUT FOR JOB 322
Application Guidelines:
The creation is rejected as long as the related F6VSWRP object does not exist in the
database.
Example of Command Execution:
Create F6TNFP:NAME=RACK:0/F6TNFP:0,WDFTNFP=CU0-FVSWRP0;

DELETE F6TNFP
DELETE F6TNFP

NAME=RACK:0..7/F6TNFP:0..11;

Command Tree:
MANAGED-ELEMENT h BSS-EQUIPMENT h BTSEP h RACK h F6TNFP h
DELETE F6TNFP
Applicability:
Phase 2 and Phase 3.
Visibility level: 2.

402

Id:0900d80580595990

A50016-G5100-B333-04-7619

BS-4x / 82 II / 240 / 241 / 240XL commands

F6TNFP

Command Description:
This command deletes the F6TNFP from the BTSE data base.
Long Names:
NAME

Address of the managed object

System Responses:
Operation Completed
After command execution, a message of Changed Configuration Notification is displayed. A further message indicates the result of the operation. An example of delete
command is the following:
JOB: 90
PC Time&Date: 17.10.2008 09:07:57 +02:00
NE Time&Date: 01.01.1990 18:49:06 +00:00
USER NAME:

User_q

COMMAND:

Delete F6TNFP:NAME=RACK:0/F6TNFP:0;

SW RELEASE:

01-04-19-01-11-07_08-10-16

COMMAND RESULT: Operation successful

END OF OUTPUT FOR JOB 90


Operation Failed
None.
Application Guidelines:
None.
Example of Command Execution:
Delete F6TNFP:NAME=RACK:0/F6TNFP:0;

GET F6TNFP
GET F6TNFP

NAME=RACK:0..7/F6TNFP:0..11 [,REQATTL=ALS, AST,


AVS, OST, PRS, RELFUNCOBJ, TNFTARGF, WDFTNFP];

Command Tree:
MANAGED-ELEMENT h BSS-EQUIPMENT h BTSEP h RACK h F6TNFP h
GET F6TNFP
Applicability:
Phase 2 and Phase 3.

A50016-G5100-B333-04-7619

Id:0900d80580595990

403

F6TNFP

BS-4x / 82 II / 240 / 241 / 240XL commands

Visibility level: 0.
Command Description:
This command displays the attributes of the F6TNFP.
Long Names:
NAME

Address of the managed object

REQATTL

Required attribute list

ALS

alarmStatus

AST

administrativeState

AVS

availabilityStatus

OST

operationalState

PRS

proceduralStatus

RELFUNCOBJ

relatedFuncObjects

TNFTARGF

tnfTargetFrequency

WDFTNFP

wiringDataFtnfp

System Responses:
Operation Completed
A message indicates the result of the operation. An example of get command is the following:
JOB: 88
PC Time&Date: 17.10.2008 09:07:54 +02:00
NE Time&Date: 01.01.1990 18:49:03 +00:00
USER NAME:

User_q

COMMAND:

Get F6TNFP:NAME=RACK:0/F6TNFP:0;

SW RELEASE:

01-04-19-01-11-07_08-10-16

COMMAND RESULT: Operation successful

alarmStatus = CLEARED
administrativeState = Locked
availabilityStatus = Dependency
operationalState = DISABLED
proceduralStatus = NULL
relatedFuncObjects = Null
tnfTargetFrequency = Null
wiringDataFtnfp =

404

Id:0900d80580595990

A50016-G5100-B333-04-7619

BS-4x / 82 II / 240 / 241 / 240XL commands

F6TNFP

CUWiring = CU0
FVSWRPWiring = FVSWRP0
END OF OUTPUT FOR JOB 88
Operation Failed
None.
Application Guidelines:
None.
Example of Command Execution:
Get F6TNFP:NAME=RACK:0/F6TNFP:0;

GETTEST F6TNFP
GETTEST F6TNFP

NAME=RACK:0..7/F6TNFP:0..11;

Command Tree:
MANAGED-ELEMENT h BSS-EQUIPMENT h BTSEP h RACK h F6TNFP h
GETTEST F6TNFP
Applicability:
Phase 2 and Phase 3.
Visibility level: 0.
Command Description:
This command displays the attributes of the object test.
Long Names:
NAME

Address of the managed object

REQATTL

Required attribute list

System Responses:
Operation Completed
A message indicates the result of the operation. An example of gettest command is the
following:
JOB: 90
PC Time&Date: 29.10.2008 16:24:05 +01:00
NE Time&Date: 01.01.1990 00:14:34 +00:00
USER NAME:

User_q

COMMAND:

Gettest F6TNFP:NAME=RACK:0/F6TNFP:0;

A50016-G5100-B333-04-7619

Id:0900d80580595990

405

F6TNFP

BS-4x / 82 II / 240 / 241 / 240XL commands

SW RELEASE:

01-04-19-01-11-08_08-10-17

COMMAND RESULT: Operation successful


END OF OUTPUT FOR JOB 90
Operation Failed
The gettest command has not been successfully executed. A general NACK will indicate
possible errors or a specific NACK strictly related to the single command is possible. An
example is the following:
JOB: 85
PC Time&Date: 28.10.2008 16:24:05 +01:00
NE Time&Date: 01.01.1990 00:14:34 +00:00
USER NAME:

User_q

COMMAND:

Gettest F6TNFP:NAME=RACK:0/F6TNFP:0;

SW RELEASE:

01-04-19-01-11-08_08-10-17

COMMAND RESULT: Operation failed

MOT = RACK:0/F6TNFP:0
Object instance unknown or not allowed (-9)
END OF OUTPUT FOR JOB 85

Application Guidelines:
None.
Example of Command Execution:
Gettest F6TNFP:NAME=RACK:0/F6TNFP:0;

LOCK F6TNFP
LOCK F6TNFP

NAME=RACK:0..7/F6TNFP:0..11;

Command Tree:
MANAGED-ELEMENT h BSS-EQUIPMENT h BTSEP h RACK h F6TNFP h
LOCK F6TNFP
Applicability:
Phase 2 and Phase 3.

406

Id:0900d80580595990

A50016-G5100-B333-04-7619

BS-4x / 82 II / 240 / 241 / 240XL commands

F6TNFP

Visibility level: 1.
Command Description:
This command changes the administrative state of F6TNFP.
Long Names:
NAME

Address of the managed object

System Responses:
Operation Completed
The specified change of administrative state has been perfomed:
JOB: 153
PC Time&Date: 24.09.2008 15:14:50 +02:00
NE Time&Date: 01.01.1990 00:31:33 +00:00
USER NAME:

User_q

COMMAND:

Lock F6TNFP:NAME=RACK:0/F6TNFP:1;

SW RELEASE:

03-04-19-01-11-05_08-09-24

COMMAND RESULT: Operation successful

administrativeState = Locked
END OF OUTPUT FOR JOB 153
Operation Failed
None.
Application Guidelines:
None.
Example of Command Execution:
Lock F6TNFP:NAME=RACK:0/F6TNFP:1;

PERFTEST F6TNFP
PERFTEST F6TNFP

NAME=RACK:0..7/F6TNFP:0..11;

Command Tree:
MANAGED-ELEMENT h BSS-EQUIPMENT h BTSEP h RACK h F6TNFP h
PERFTEST F6TNFP
Applicability:
Phase 2 and Phase 3.

A50016-G5100-B333-04-7619

Id:0900d80580595990

407

F6TNFP

BS-4x / 82 II / 240 / 241 / 240XL commands

Visibility level: 1.
Command Description:
This command is used to start an asynchronous test in the object.
Long Names:
NAME

Address of the managed object

System Responses:
Operation Completed
Test configuration has been set and the specified test has been started.
JOB: 23
PC Time&Date: 26.09.2008 13:06:13 +02:00
NE Time&Date: 26.09.2008 10:13:31 +01:00
USER NAME:

User_q

COMMAND:

Perftest F6TNFP:NAME=RACK:0/F6TNFP:0;

SW RELEASE:

03-04-19-01-11-05_08-09-24

COMMAND RESULT: Operation successful

MOT = RACK:0/F6TNFP:0
tO = BTSETEST:8
END OF OUTPUT FOR JOB 23
Operation Failed
The specified test cannot be performed. In addition to the general NACK causes, a
specific NACK cause, which indicates that the command is inconsistent with the
physical configuration, is possible. An example is the following:
JOB: 89
PC Time&Date: 24.09.2008 14:21:15 +02:00
NE Time&Date: 24.09.2008 10:29:49 +00:00
USER NAME:

User_q

COMMAND:

Perftest F6TNFP:NAME=RACK:0/F6TNFP:1;

SW RELEASE:

03-04-19-01-11-05_08-09-24

COMMAND RESULT: Operation failed

408

Id:0900d80580595990

A50016-G5100-B333-04-7619

BS-4x / 82 II / 240 / 241 / 240XL commands

F6TNFP

MOT = RACK:0/F6TNFP:1
MO or MOT not locked (-151)
END OF OUTPUT FOR JOB 89
Application Guidelines:
None.
Example of Command Execution:
Perftest F6TNFP:NAME=RACK:0/F6TNFP:0;

STOPTEST F6TNFP
STOPTEST F6TNFP

NAME=RACK:0..7/F6TNFP:0..11;

Command Tree:
MANAGED-ELEMENT h BSS-EQUIPMENT h BTSEP h RACK h F6TNFP h
STOPTEST F6TNFP
Applicability:
Phase 2 and Phase 3.
Visibility level: 1.
Command Description:
This command is used to stop a diagnostic previously started.
Long Names:
NAME

Address of the managed object

System Responses:
Operation Completed
Test has been stopped. The System Responses will not be addressed to the MOT but
to the object.

Result TEST:
name =

TEST:<n>

testOutcome =

inconclusive

mOts =

It is the identifier of the hardware object under test.

testTermination =

Cancel

executedPhases
phaseId =
...
.

A50016-G5100-B333-04-7619

It represents the list of the executed test phases; the


list is not shown for test in the waiting list (queued).

Id:0900d80580595990

409

F6TNFP

BS-4x / 82 II / 240 / 241 / 240XL commands

failedPhases
phaseId =

It represents the list of the failed test phase;

phaseId =

additional information is provided for each phase.

....
skippedPhases
phaseId =

It represents the list of the skipped phases;the list is


not shown for test in the waiting list (queued).

phaseId =
Operation Failed

The specified test has not been stopped. In addition to the general NACK causes, a
specific NACK cause, which indicates that the command is inconsistent with the
physical configuration, is possible. An example is the following:
JOB: 214
PC Time&Date: 17.10.2008 09:14:33 +02:00
NE Time&Date: 01.01.1990 18:55:42 +00:00
USER NAME:

User_q

COMMAND:

Stoptest F6TNFP:NAME=RACK:0/F6TNFP:0;

SW RELEASE:

01-04-19-01-11-07_08-10-16

COMMAND RESULT: Operation failed

MOT = RACK:0/F6TNFP:0
Object instance unknown or not allowed (-9)
END OF OUTPUT FOR JOB 214
Application Guidelines:
None.
Example of Command Execution:
Stoptest F6TNFP:NAME=RACK:0/F6TNFP:0;

UNLOCK F6TNFP
UNLOCK F6TNFP

NAME=RACK:0..7/F6TNFP:0..11;

Command Tree:
MANAGED-ELEMENT h BSS-EQUIPMENT h BTSEP h RACK h F6TNFP h
UNLOCK F6TNFP

410

Id:0900d80580595990

A50016-G5100-B333-04-7619

BS-4x / 82 II / 240 / 241 / 240XL commands

F6TNFP

Applicability:
Phase 2 and Phase 3.
Visibility level: 1.
Command Description:
This command changes the administrative state of F6TNFP.
Long Names:
NAME

Address of the managed object

System Responses:
Operation Completed
The specified change of administrative state has been perfomed:
JOB: 93
PC Time&Date: 24.09.2008 14:21:38 +02:00
NE Time&Date: 24.09.2008 10:30:12 +00:00
USER NAME:

User_q

COMMAND:

Unlock F6TNFP:NAME=RACK:0/F6TNFP:0;

SW RELEASE:

03-04-19-01-11-05_08-09-24

COMMAND RESULT: Operation successful

administrativeState = Unlocked
END OF OUTPUT FOR JOB 93
Operation Failed
None.
Application Guidelines:
None.
Example of Command Execution:
Unlock F6TNFP:NAME=RACK:0/F6TNFP:0;

A50016-G5100-B333-04-7619

Id:0900d80580595990

411

F6VSWRP

BS-4x / 82 II / 240 / 241 / 240XL commands

F6VSWRP
The F6VSWRP object represents common functions of one FICOM6. The objects
creation is therefore mandatory if the module is equipped.

CREATE F6VSWRP
CREATE F6VSWRP

NAME=RACK:0..7/F6VSWRP:0..1 ,CELLNO=
[,VSWRTDB=];

Command Tree:
MANAGED-ELEMENT h BSS-EQUIPMENT h BTSEP h RACK h F6VSWRP h
CREATE F6VSWRP
Applicability:
Phase 2 and Phase 3.
Visibility level: 2.
Command Description:
This command adds the F6VSWRP to the BTSE data base.
Long Names:
NAME

Address of the managed object

CELLNO

cellNumber

VSWRTDB

vswrThresholdDb

System Responses:
Operation Completed
After command execution, a message of Changed Configuration Notification is displayed. A further message indicates the result of the operation. An example of create
command is the following:
JOB: 36
PC Time&Date: 25.09.2008 14:47:06 +02:00
NE Time&Date: 02.01.1990 00:03:47 +00:00
USER NAME:

User_s

COMMAND:
Create
F6VSWRP:NAME=RACK:0/F6VSWRP:0,CELLNO=0,VSWRTDB=LOW_2_5_HIGH_3
_5;
SW RELEASE:

03-04-19-01-11-05_08-09-24

COMMAND RESULT: Operation successful


cellNumber = 0

412

Id:0900d80580595992

A50016-G5100-B333-04-7619

BS-4x / 82 II / 240 / 241 / 240XL commands

F6VSWRP

vswrThresholdDb = LOW_2_5_HIGH_3_5
END OF OUTPUT FOR JOB 36
Operation Failed
The specified Object has not been created. In addition to the general NACK causes, a
specific NACK cause, which indicates that the command is inconsistent with the
physical configuration, is possible. An example is the following:
JOB: 85
PC Time&Date: 16.09.2008 15:48:10 +02:00
NE Time&Date: 01.01.1990 00:08:52 +00:00
USER NAME:

User_s

COMMAND:

Create F6VSWRP:NAME=RACK:0/F6VSWRP:0,CELLNO=1;

SW RELEASE:

01-04-19-01-12-MB_08-09-16

COMMAND RESULT: Operation failed


cellNumber = 1
message cannot be performed (-17)
END OF OUTPUT FOR JOB 85
Application Guidelines:

The creation is mandatory if the module is equipped

The creation is rejected if any other combiner instance (DUAMCO, DUVSWR,


DULNA, DUDCTMA, FVSWRP, FTNFP, BCOM) is already created for the related
ACOM slots

The creation of any other combiner object has to be rejected if a FICOM6 object is
created for the slot(s)

Example of Command Execution:


Create
F6VSWRP:NAME=RACK:0/F6VSWRP:0,CELLNO=0,VSWRTDB=LOW_2_5_HIGH_3
_5;

DELETE F6VSWRP
DELETE F6VSWRP

NAME=RACK:0..7/F6VSWRP:0..1;

Command Tree:
MANAGED-ELEMENT h BSS-EQUIPMENT h BTSEP h RACK h F6VSWRP h
DELETE F6VSWRP

A50016-G5100-B333-04-7619

Id:0900d80580595992

413

F6VSWRP

BS-4x / 82 II / 240 / 241 / 240XL commands

Applicability:
Phase 2 and Phase 3.
Visibility level: 2.
Command Description:
This command deletes the F6VSWRP from the BTSE data base.
Long Names:
NAME

Address of the managed object

System Responses:
Operation Completed
After command execution, a message of Changed Configuration Notification is displayed. A further message indicates the result of the operation. An example of create
command is the following:
JOB: 25
PC Time&Date: 25.09.2008 14:46:50 +02:00
NE Time&Date: 02.01.1990 00:03:31 +00:00
USER NAME:

User_s

COMMAND:

Delete F6VSWRP:NAME=RACK:0/F6VSWRP:0;

SW RELEASE:

03-04-19-01-11-05_08-09-24

COMMAND RESULT: Operation successful


END OF OUTPUT FOR JOB 25
Operation Failed
The specified Object has not been created. In addition to the general NACK causes, a
specific NACK cause, which indicates that the command is inconsistent with the
physical configuration, is possible. An example is the following:
JOB: 26
PC Time&Date: 25.09.2008 14:46:50 +02:00
NE Time&Date: 02.01.1990 00:03:31 +00:00
USER NAME:

User_s

COMMAND:

Delete F6VSWRP:NAME=RACK:0/F6VSWRP:0;

SW RELEASE:

03-04-19-01-11-05_08-09-24

COMMAND RESULT: Operation failed

414

Id:0900d80580595992

A50016-G5100-B333-04-7619

BS-4x / 82 II / 240 / 241 / 240XL commands

F6VSWRP

Deletion out of sequence (-166)


END OF OUTPUT FOR JOB 26
Application Guidelines:
The deletion of the F6VSWRP object has to be rejected as long as another FICOM6
object (F6TNFP, F6LNA, F6DCTMA) exists for the same ACOM slots.
Example of Command Execution:
Delete F6VSWRP:NAME=RACK:0/F6VSWRP:0;

GET F6VSWRP
GET F6VSWRP

NAME=RACK:0..7/F6VSWRP:0..1 [,REQATTL=ALS, AST,


AVS, CELLNO, OST, PRS, RELFUNCOBJ, VSWRTDB,
F6FWID];

Command Tree:
MANAGED-ELEMENT h BSS-EQUIPMENT h BTSEP h RACK h F6VSWRP h
GET F6VSWRP
Applicability:
Phase 2 and Phase 3.
Visibility level: 0.
Command Description:
This command displays the attributes of the F6VSWRP.
Long Names:
NAME

Address of the managed object

REQATTL

Required attribute list

ALS

alarmStatus

AST

administrativeState

AVS

availabilityStatus

CELLNO

cellNumber

OST

operationalState

PRS

proceduralStatus

RELFUNCOBJ

relatedFuncObjects

VSWRTDB

vswrThresholdDb

F6FWID

ficom6FwId

System Responses:
Operation Completed
A message indicates the result of the operation. An example of get command is the following:

A50016-G5100-B333-04-7619

Id:0900d80580595992

415

F6VSWRP

BS-4x / 82 II / 240 / 241 / 240XL commands

JOB: 148
PC Time&Date: 16.09.2008 16:06:01 +02:00
NE Time&Date: 01.01.1990 00:26:43 +00:00
USER NAME:

User_s

COMMAND:

Get F6VSWRP:NAME=RACK:0/F6VSWRP:0;

SW RELEASE:

01-04-19-01-12-MB_08-09-16

COMMAND RESULT: Operation successful

alarmStatus = CLEARED
administrativeState = Unlocked
availabilityStatus = NotInstalled
cellNumber = 1
operationalState = DISABLED
proceduralStatus = NULL
relatedFuncObjects = Null
vswrThresholdDb = LOW_2_0_HIGH_3_0
ficom6FwId = "BFFCiihh.SWI:00-hh-19-ii-ss-00_08-01-01"
END OF OUTPUT FOR JOB 148
Operation Failed
None.
Application Guidelines:
None.
Example of Command Execution:
Get F6VSWRP:NAME=F6VSWRP:0, REQATTL=ALS& AST& AVS& CELLNO& OST&
PRS& RELFUNCOBJ& VSWRTDB& F6FWID;

GETTEST F6VSWRP
GETTEST F6VSWRP

NAME=RACK:0..7/F6VSWRP:0..1;

Command Tree:
MANAGED-ELEMENT h BSS-EQUIPMENT h BTSEP h RACK h F6VSWRP h
GETTEST F6VSWRP
Applicability:
Phase 2 and Phase 3.
Visibility level: 0.

416

Id:0900d80580595992

A50016-G5100-B333-04-7619

BS-4x / 82 II / 240 / 241 / 240XL commands

F6VSWRP

Command Description:
This command displays the attributes of the object test.
Long Names:
NAME

Address of the managed object

REQATTL

Required attribute list

System Responses:
Operation Completed
A message indicates the result of the operation. An example of gettest command is the
following:
JOB: 296
PC Time&Date: 17.09.2008 16:12:51 +02:00
NE Time&Date: 17.09.2008 13:21:24 +01:00
USER NAME:

User_s

COMMAND:

Gettest F6VSWRP:NAME=RACK:0/F6VSWRP:1;

SW RELEASE:

01-04-19-01-12-MB_08-09-12

COMMAND RESULT: Operation successful


END OF OUTPUT FOR JOB 296
Operation Failed
None.
Application Guidelines:
None.
Example of Command Execution:
Gettest F6VSWRP:NAME=RACK:0/F6VSWRP:0;

LOCK F6VSWRP
LOCK F6VSWRP

NAME=RACK:0..7/F6VSWRP:0..1;

Command Tree:
MANAGED-ELEMENT h BSS-EQUIPMENT h BTSEP h RACK h F6VSWRP h
LOCK F6VSWRP
Applicability:
Phase 2 and Phase 3.
Visibility level: 1.

A50016-G5100-B333-04-7619

Id:0900d80580595992

417

F6VSWRP

BS-4x / 82 II / 240 / 241 / 240XL commands

Command Description:
This command changes the administrative state of F6VSWRP.
Long Names:
NAME

Address of the managed object

System Responses:
Operation Completed
The specified change of administrative state has been perfomed:
JOB: 228
PC Time&Date: 17.09.2008 16:03:11 +02:00
NE Time&Date: 17.09.2008 13:11:44 +01:00
USER NAME:

User_s

COMMAND:

Lock F6VSWRP:NAME=RACK:0/F6VSWRP:0;

SW RELEASE:

01-04-19-01-12-MB_08-09-12

COMMAND RESULT: Operation successful


administrativeState = Locked
END OF OUTPUT FOR JOB 228
Operation Failed
None.
Application Guidelines:
None.
Example of Command Execution:
Lock F6VSWRP:NAME=RACK:0/F6VSWRP:0;

PERFTEST F6VSWRP
PERFTEST F6VSWRP

NAME=RACK:0..7/F6VSWRP:0..1;

Command Tree:
MANAGED-ELEMENT h BSS-EQUIPMENT h BTSEP h RACK h F6VSWRP h
PERFTEST F6VSWRP
Applicability:
Phase 2 and Phase 3.
Visibility level: 1.

418

Id:0900d80580595992

A50016-G5100-B333-04-7619

BS-4x / 82 II / 240 / 241 / 240XL commands

F6VSWRP

Command Description:
This command is used to start an asynchronous test in the object.
Long Names:
NAME

Address of the managed object

System Responses:
Operation Completed
After command execution, a message of Changed Configuration Notification is displayed. A further message indicates the result of the operation. An example of perftest
command is the following:
JOB: 35
PC Time&Date: 26.09.2008 13:06:37 +02:00
NE Time&Date: 26.09.2008 10:13:55 +01:00
USER NAME:

User_s

COMMAND:

Perftest F6VSWRP:NAME=RACK:0/F6VSWRP:0;

SW RELEASE:

03-04-19-01-11-05_08-09-24

COMMAND RESULT: Operation successful


MOT = RACK:0/F6VSWRP:0
tO = BTSETEST:9
END OF OUTPUT FOR JOB 35
Operation Failed
None.
Application Guidelines:
None.
Example of Command Execution:
Perftest F6VSWRP:NAME=RACK:0/F6VSWRP:0;

SET F6VSWRP
SET F6VSWRP

NAME=RACK:0..7/F6VSWRP:0..1 [,VSWRTDB=];

Command Tree:
MANAGED-ELEMENT h BSS-EQUIPMENT h BTSEP h RACK h F6VSWRP h
SET F6VSWRP
Applicability:
Phase 2 and Phase 3.

A50016-G5100-B333-04-7619

Id:0900d80580595992

419

F6VSWRP

BS-4x / 82 II / 240 / 241 / 240XL commands

Visibility level: 2.
Command Description:
This command sets general attributes of the F6VSWRP.
Long Names:
NAME

Address of the managed object

VSWRTDB

vswrThresholdDb

System Responses:
Operation Completed
After command execution, a message of Changed Attribute Event Report is displayed.
A further message indicates the result of the operation. An example of set command is
the following:
JOB: 53
PC Time&Date: 24.09.2008 14:13:35 +02:00
NE Time&Date: 24.09.2008 10:22:09 +00:00
USER NAME:

User_s

COMMAND:
Set
F6VSWRP:NAME=RACK:0/F6VSWRP:0,VSWRTDB=LOW_3_0_HIGH_4_0;
SW RELEASE:

03-04-19-01-11-05_08-09-24

COMMAND RESULT: Operation successful

vswrThresholdDb = LOW_3_0_HIGH_4_0
END OF OUTPUT FOR JOB 53
Operation Failed
None.
Application Guidelines:
None.
Example of Command Execution:
Set F6VSWRP:NAME=RACK:0/F6VSWRP:0,VSWRTDB=LOW_3_0_HIGH_4_0;

STOPTEST F6VSWRP
STOPTEST F6VSWRP

420

NAME=RACK:0..7/F6VSWRP:0..1;

Id:0900d80580595992

A50016-G5100-B333-04-7619

BS-4x / 82 II / 240 / 241 / 240XL commands

F6VSWRP

Command Tree:
MANAGED-ELEMENT h BSS-EQUIPMENT h BTSEP h RACK h F6VSWRP h
STOPTEST F6VSWRP
Applicability:
Phase 2 and Phase 3.
Visibility level: 1.
Command Description:
This command is used to stop a diagnostic previously started.
Long Names:
NAME

Address of the managed object

System Responses:
Operation Completed
Test has been stopped. The System Responses will not be addressed to the MOT but
to the object.

Result TEST:
name =

TEST:<n>

testOutcome =

inconclusive

mOts =

It is the identifier of the hardware object under test.

testTermination =

Cancel

executedPhases
phaseId =

It represents the list of the executed test phases; the


list is not shown for test in the waiting list (queued).

...
.
failedPhases
phaseId =

It represents the list of the failed test phase;

phaseId =

additional information is provided for each phase.

....
skippedPhases
phaseId =
phaseId =

It represents the list of the skipped phases;the list is


not shown for test in the waiting list (queued).

Operation Failed
The specified action has not been performed. In addition to the general NACK causes,
a specific NACK cause, which indicates that the command is inconsistent with the
physical configuration, is possible. An example is the following:
JOB: 244

A50016-G5100-B333-04-7619

Id:0900d80580595992

421

F6VSWRP

BS-4x / 82 II / 240 / 241 / 240XL commands

PC Time&Date: 17.09.2008 16:07:01 +02:00


NE Time&Date: 17.09.2008 13:15:34 +01:00
USER NAME:

User_s

COMMAND:

Stoptest F6VSWRP:NAME=RACK:0/F6VSWRP:1;

SW RELEASE:

01-04-19-01-12-MB_08-09-12

COMMAND RESULT: Operation failed

MOT = RACK:0/F6VSWRP:1
Object instance unknown or not allowed (-9)
END OF OUTPUT FOR JOB 244

Application Guidelines:
None.
Example of Command Execution:
Stoptest F6VSWRP:NAME=RACK:0/F6VSWRP:0;

UNLOCK F6VSWRP
UNLOCK F6VSWRP

NAME=RACK:0..7/F6VSWRP:0..1;

Command Tree:
MANAGED-ELEMENT h BSS-EQUIPMENT h BTSEP h RACK h F6VSWRP h
UNLOCK F6VSWRP
Applicability:
Phase 2 and Phase 3.
Visibility level: 1.
Command Description:
This command changes the administrative state of F6VSWRP.
Long Names:
NAME

Address of the managed object

System Responses:
Operation Completed
The specified change of administrative state has been perfomed:
JOB: 227

422

Id:0900d80580595992

A50016-G5100-B333-04-7619

BS-4x / 82 II / 240 / 241 / 240XL commands

F6VSWRP

PC Time&Date: 17.09.2008 16:03:02 +02:00


NE Time&Date: 17.09.2008 13:11:35 +01:00
USER NAME:

User_s

COMMAND:

Unlock F6VSWRP:NAME=RACK:0/F6VSWRP:0;

SW RELEASE:

01-04-19-01-12-MB_08-09-12

COMMAND RESULT: Operation successful


administrativeState = Unlocked
END OF OUTPUT FOR JOB 227
Operation Failed
None.
Application Guidelines:
None.
Example of Command Execution:
Unlock F6VSWRP:NAME=RACK:0/F6VSWRP:0;

A50016-G5100-B333-04-7619

Id:0900d80580595992

423

FANP

BS-4x / 82 II / 240 / 241 / 240XL commands

FANP
The self controlled central FAN units are used in order to guarantee a sufficient airflow
for convection cooling of the modules. Two fans are responsible for each sub-rack. An
integrated temperature sensor enables the fan control.

CREATE FANP
CREATE FANP

NAME=RACK:0..7/FANP:0..7;

Command Tree:
MANAGED-ELEMENT h BSS-EQUIPMENT h BTSEP h RACK h FANP h
CREATE FANP
Applicability:
Phase 2 and Phase 3.
Visibility level: 2.
Command Description:
This command adds the FANP unit to the BTSE data base.
Long Names:
NAME

Address of the managed object

System Responses:
Operation Completed
After command execution, a message of Changed Configuration Notification is displayed.
A further message indicates the result of the operation. An example of create command
is the following:
JOB: 147
PC Time&Date: 12:01:41 03/23/2005
NE Time&Date: 13:03:16 09/15/2004
USER NAME:

User_t

SW RELEASE:

01-04-17-01-26-51_05-02-23

COMMAND RESULT: Operation successful


ChangedConfigurationNotification:
name = RACK:0/FANP:0
ChangeInfo = created

424

Id:0900d80580595994

A50016-G5100-B333-04-7619

BS-4x / 82 II / 240 / 241 / 240XL commands

FANP

END OF OUTPUT FOR JOB 147


JOB: 148
PC Time&Date: 12:01:41 03/23/2005
NE Time&Date: 13:03:16 09/15/2004
USER NAME:

User_t

COMMAND:

Create FANP:NAME=RACK:0/FANP:0;

SW RELEASE:

01-04-17-01-26-51_05-02-23

COMMAND RESULT: Operation successful


END OF OUTPUT FOR JOB 148
Operation Failed
The specified Object has not been created. In addition to the general NACK causes, a
specific NACK cause, which indicates that the command is inconsistent with the
physical configuration, is possible. An example is the following:
JOB: 149
PC Time&Date: 12:02:04 03/23/2005
NE Time&Date: 13:03:39 09/15/2004
USER NAME:

User_t

COMMAND:

Create FANP:NAME=RACK:0/FANP:0;

SW RELEASE:

01-04-17-01-26-51_05-02-23

COMMAND RESULT: OPERATION FAILED


message cannot be performed (-17)
END OF OUTPUT FOR JOB 149
Application Guidelines:

In operation, all FANPs must be created

The maximum number of FANPs is: 6 for BS240/241/240SR/241SR and BS40/41,


8 for BS240XL/BS240XLSR, 5 for BS40II and 1 for BS82II

The FANP object is always created with status unlocked.enable.null.null.cleared. If


the HW is not connected or not present or if the board has a HW failure the object is
then immediatly set to unlocked.disabled.failed

A50016-G5100-B333-04-7619

Id:0900d80580595994

425

FANP

BS-4x / 82 II / 240 / 241 / 240XL commands

If the operator creates in advance the object FANP in an extension rack which is not
yet connected to the Base rack or if the ACT is not enabled, the FANP always keep
the states unlocked.enabled.null.null.cleared and no alarm is visible, even if the
FAN-HW is not present or the board has an HW-failure

In the BS82 II the ACT must also be enabled in the base rack for correct displaying
of the FAN status

Example of Command Execution:


Create FANP:NAME=RACK:0/FANP:0;

DELETE FANP
DELETE FANP

NAME=RACK:0..7/FANP:0..7;

Command Tree:
MANAGED-ELEMENT h BSS-EQUIPMENT h BTSEP h RACK h FANP h
DELETE FANP
Applicability:
Phase 2 and Phase 3.
Visibility level: 2.
Command Description:
This command deletes the FANP unit from the BTSE data base.
Long Names:
NAME

Address of the managed object

System Responses:
Operation Completed
After command execution, a message of Changed Configuration Notification is displayed. A further message indicates the result of the operation. An example of delete
command is the following:
JOB: 145
PC Time&Date: 12:01:38 03/23/2005
NE Time&Date: 13:03:13 09/15/2004
USER NAME:

User_t

SW RELEASE:

01-04-17-01-26-51_05-02-23

COMMAND RESULT: Operation successful


ChangedConfigurationNotification:
name = RACK:0/FANP:0

426

Id:0900d80580595994

A50016-G5100-B333-04-7619

BS-4x / 82 II / 240 / 241 / 240XL commands

FANP

ChangeInfo = deleted
END OF OUTPUT FOR JOB 145
JOB: 146
PC Time&Date: 12:01:38 03/23/2005
NE Time&Date: 13:03:13 09/15/2004
USER NAME:

User_t

COMMAND:

Delete FANP:NAME=RACK:0/FANP:0;

SW RELEASE:

01-04-17-01-26-51_05-02-23

COMMAND RESULT: Operation successful


END OF OUTPUT FOR JOB 146
Operation Failed
The specified Object has not been deleted. Additionally to the general NACK causes, a
specific NACK cause, meaning that the command is inconsistent with physical configuration, is possible.
Application Guidelines:

FANP must be locked in Phase 3, before deletion

The deletion of a FANP is critical in operation

Example of Command Execution:


Delete FANP:NAME=RACK:0/FANP:0;

GET FANP
GET FANP

NAME=RACK:0..7/FANP:0..7 [,REQATTL=ALS, AST, AVS,


OST, PRS, RELFUNCOBJ];

Command Tree:
MANAGED-ELEMENT h BSS-EQUIPMENT h BTSEP h RACK h FANP h GET
FANP
Applicability:
Phase 2 and Phase 3.
Visibility level: 0.
Command Description:
This command displays the attributes of the FANP units of the BTSE.
Long Names:
NAME

A50016-G5100-B333-04-7619

Address of the managed object

Id:0900d80580595994

427

FANP

BS-4x / 82 II / 240 / 241 / 240XL commands

REQATTL

Required attribute list

ALS

alarmStatus

AST

administrativeState

AVS

availabilityStatus

OST

operationalState

PRS

proceduralStatus

RELFUNCOBJ

relatedFuncObjects

System Responses:
Operation Completed
A message indicates the result of the operation. An example of get command is the following:
JOB: 132
PC Time&Date: 12:01:18 03/23/2005
NE Time&Date: 13:02:53 09/15/2004
USER NAME:

User_t

COMMAND:

Get FANP:NAME=RACK:0/FANP:0;

SW RELEASE:

01-04-17-01-26-51_05-02-23

COMMAND RESULT: Operation successful


alarmStatus = CLEARED
administrativeState = Unlocked
availabilityStatus = NULL
operationalState = ENABLED
proceduralStatus = NULL
relatedFuncObjects =
END OF OUTPUT FOR JOB 132
Operation Failed
The GET command has not been successfully executed. A general NACK will indicate
possible errors or a specific NACK strictly related to the single command is possible.
Application Guidelines:

The value for ProcStatus must be Null Status

The relatedFuncObjects always empty

Example of Command Execution:


Get FANP:NAME=RACK:0/FANP:0,REQATTL=ALS&AST&AVS&OST&PRS;

428

Id:0900d80580595994

A50016-G5100-B333-04-7619

BS-4x / 82 II / 240 / 241 / 240XL commands

FANP

GETTEST FANP
GETTEST FANP

NAME=RACK:0..7/FANP:0..7;

Command Tree:
MANAGED-ELEMENT h BSS-EQUIPMENT h BTSEP h RACK h FANP h
GETTEST FANP
Applicability:
Phase 2 and Phase 3.
Visibility level: 0.
Command Description:
This command displays the attributes of the FANP test.
Long Names:
NAME

Address of the managed object

REQATTL

Required attribute list

System Responses:
Operation Completed
A message indicates the result of the operation. An example of gettest command is the
following:
JOB: 140
PC Time&Date: 12:01:25 03/23/2005
NE Time&Date: 13:03:00 09/15/2004
USER NAME:

User_t

COMMAND:

Gettest FANP:NAME=RACK:0/FANP:0;

SW RELEASE:

01-04-17-01-26-51_05-02-23

COMMAND RESULT: Operation successful


MOT = RACK:0/FANP:0
testMonitor =
phaseId = PreliminaryTestsFanp
phaseStatus = Running
phaseId = CheckAlarmStatusFanp
phaseStatus = Waiting
phaseId = EndTestFanp
phaseStatus = Waiting
testOutcome = INCONCLUSIVE
testState = INITIALIZING

A50016-G5100-B333-04-7619

Id:0900d80580595994

429

FANP

BS-4x / 82 II / 240 / 241 / 240XL commands

END OF OUTPUT FOR JOB 140


Operation Failed
The GET command has not been successfully executed. A general NACK will indicate
possible errors or a specific NACK strictly related to the single command is possible.
testMonitor
phaseId =
phaseStatus =

it is a list of all test phases related to the


selected object; for each phase the
related phaseStatus is provided (Passed,
Failed, Running or Waiting).

phaseId =
phaseStatus =
...
...
testOutcome

It represents the test result: it can be


Inconclusive (if the phases already
executed were successful) or Fail (if at
least one of the executed phases failed).

testState = Testing

It can assume one of the following values:


not_initialized, idle, initializing, suspended, testing, terminating and disabled.

Application Guidelines:
None.
Example of Command Execution:
Gettest FANP:NAME=RACK:0/FANP:0;

LOCK FANP
LOCK FANP

NAME=RACK:0..7/FANP:0..7;

Command Tree:
MANAGED-ELEMENT h BSS-EQUIPMENT h BTSEP h RACK h FANP h
LOCK FANP
Applicability:
Phase 2 and Phase 3.
Visibility level: 1.
Command Description:
This command changes the administrative state of the FANP unit of the BTSE.
Long Names:
NAME

430

Address of the managed object

Id:0900d80580595994

A50016-G5100-B333-04-7619

BS-4x / 82 II / 240 / 241 / 240XL commands

FANP

System Responses:
Operation Completed
The specified change of administrative state has been perfomed:
JOB: 143
PC Time&Date: 12:01:36 03/23/2005
NE Time&Date: 13:03:11 09/15/2004
USER NAME:

User_t

COMMAND:

Lock FANP:NAME=RACK:0/FANP:0;

SW RELEASE:

01-04-17-01-26-51_05-02-23

COMMAND RESULT: Operation successful


administrativeState = Locked
END OF OUTPUT FOR JOB 143

CHANGED STATE EVENT REPORT:


This provides information about the administrative state, the operational state and the
availability status every time a state change occurs:
JOB: 144
PC Time&Date: 12:01:36 03/23/2005
NE Time&Date: 13:03:11 09/15/2004
USER NAME:

User_t

SW RELEASE:

01-04-17-01-26-51_05-02-23

COMMAND RESULT: Operation successful


CHANGED STATE EVENT REPORT:
NAME = RACK:0/FANP:0
Administrative State = LOCKED
Notification Identifier = 341
END OF OUTPUT FOR JOB 144

A50016-G5100-B333-04-7619

Id:0900d80580595994

431

FANP

BS-4x / 82 II / 240 / 241 / 240XL commands

Operation Failed
The specified change of administrative state has not been performed.
Application Guidelines:

After locking of the FANP, the FANP will still be in operation, but in the administrative
state Locked

Example of Command Execution:


Lock FANP:NAME=RACK:0/FANP:0;

PERFTEST FANP
PERFTEST FANP

NAME=RACK:0..7/FANP:0..7;

Command Tree:
MANAGED-ELEMENT h BSS-EQUIPMENT h BTSEP h RACK h FANP h
PERFTEST FANP
Applicability:
Phase 2 and Phase 3.
Visibility level: 1.
Command Description:
This command is used to start an asynchronous test in FANP.
Long Names:
NAME

Address of the managed object

System Responses:
Operation Completed
Test configuration has been set and the specified test has been started. The System
response will not be addressed to the MOT but to the object BTSEP.
JOB: 136
PC Time&Date: 12:01:25 03/23/2005
NE Time&Date: 13:03:00 09/15/2004
USER NAME:

User_t

COMMAND:

Perftest FANP:NAME=RACK:0/FANP:0;

SW RELEASE:

01-04-17-01-26-51_05-02-23

COMMAND RESULT: Operation successful


MOT = RACK:0/FANP:0
tO = BTSETEST:6

432

Id:0900d80580595994

A50016-G5100-B333-04-7619

BS-4x / 82 II / 240 / 241 / 240XL commands

FANP

END OF OUTPUT FOR JOB 136

JOB: 137
PC Time&Date: 12:01:25 03/23/2005
NE Time&Date: 13:03:00 09/15/2004
USER NAME:

User_t

SW RELEASE:

01-04-17-01-26-51_05-02-23

COMMAND RESULT: Operation successful


ChangedConfigurationNotification:
name = BTSETEST:6
ChangeInfo = created
END OF OUTPUT FOR JOB 137
JOB: 138
PC Time&Date: 12:01:25 03/23/2005
NE Time&Date: 13:03:00 09/15/2004
USER NAME:

User_t

SW RELEASE:

01-04-17-01-26-51_05-02-23

COMMAND RESULT: Operation successful


CHANGED STATE EVENT REPORT:
NAME = RACK:0/FANP:0
Operational State = ENABLED
Availability Status = NULL_value
Notification Identifier = 339
END OF OUTPUT FOR JOB 138

A50016-G5100-B333-04-7619

Id:0900d80580595994

433

FANP

BS-4x / 82 II / 240 / 241 / 240XL commands

JOB: 139
PC Time&Date: 12:01:25 03/23/2005
NE Time&Date: 13:03:00 09/15/2004
USER NAME:

User_t

SW RELEASE:

01-04-17-01-26-51_05-02-23

COMMAND RESULT: Operation successful


Test Report:
name = BTSETEST:6
testOutcome = PASSED
testTermination = Normal
MOT = RACK:0/FANP:0
executedPhases =
PreliminaryTestsFanp
CheckAlarmStatusFanp
EndTestFanp
END OF OUTPUT FOR JOB 139
JOB: 140
PC Time&Date: 12:01:25 03/23/2005
NE Time&Date: 13:03:00 09/15/2004
USER NAME:

User_t

SW RELEASE:

01-04-17-01-26-51_05-02-23

COMMAND RESULT: Operation successful


ChangedConfigurationNotification:
name = BTSETEST:6
ChangeInfo = deleted
END OF OUTPUT FOR JOB 140
The test results will be displayed at the end of the test phases.

434

Id:0900d80580595994

A50016-G5100-B333-04-7619

BS-4x / 82 II / 240 / 241 / 240XL commands

FANP

Result TEST:
name =

TEST:<n>

testOutcome =

This field represents the test result; one of the following values can be displayed:
Pass

all the test phases are successfully


performed.

Inconclusive

the test is aborted by the system or


the test is terminated by the operator.

Fail

if at least one of the executed phases


fail.

mOts =

It is the identifier of the hardware object under test.

testTermination =

It specifies how the test is terminated, it can assume


the following values:
Normal

all the test phases are performed.

Abort

the test is aborted by system.

Cancel

the test is terminated by operator.

executedPhases
phaseId =
additionalWords =
....

It represents the list of the executed test phases (in


case of successful test result, all the test phases will
be listed).

failedPhases
phaseId =

It represents the list of the failed test phase; additional information is provided for each phase.

phaseId =
....
skippedPhases
phaseId =

It represents the list of the skipped phases; they are


displayed only for test stopped during it execution.

phaseId =
....
poprosedRepair Action
=

A list of most probable fail probable causes is shown


(max four messages)

Operation Failed
This NACK-message occurs in the following cases: message cannot be performed, test
not supported, capacity restrictions, physical configuration cannot be performed, object
not locked.
Application Guidelines:

In phase 3 MO must be locked previous to the command execution

A50016-G5100-B333-04-7619

Id:0900d80580595994

435

FANP

BS-4x / 82 II / 240 / 241 / 240XL commands

Example of Command Execution:


Perftest FANP:NAME=RACK:0/FANP:0;

STOPTEST FANP
STOPTEST FANP

NAME=RACK:0..7/FANP:0..7;

Command Tree:
MANAGED-ELEMENT h BSS-EQUIPMENT h BTSEP h RACK h FANP h
STOPTEST FANP
Applicability:
Phase 2 and Phase 3.
Visibility level: 1.
Command Description:
This command is used to stop a diagnostic previously started.
Long Names:
NAME

Address of the managed object

System Responses:
Operation Completed
Test has been stopped. The System Responses will not be addressed to the MOT but
to the object BTSEP.

Result TEST:
name =

TEST:<n>

testOutcome =

inconclusive

mOts =

It is the identifier of the hardware object under test.

testTermination =

Cancel

executedPhases
phaseId =
...
.

It represents the list of the executed test phases; the


list is not shown for test in the waiting list (queued).

failedPhases
phaseId =

It represents the list of the failed test phase;

phaseId =

additional information is provided for each phase.

....
skippedPhases
phaseId =
phaseId =

436

It represents the list of the skipped phases;the list is


not shown for test in the waiting list (queued).

Id:0900d80580595994

A50016-G5100-B333-04-7619

BS-4x / 82 II / 240 / 241 / 240XL commands

FANP

Operation Failed
Test has not been stopped. This NACK-message can occur when the specified test is
not running or in case of test which cannot be stopped.
Application Guidelines:
None.
Example of Command Execution:
Stoptest FANP:NAME=RACK:0/FANP:0;

UNLOCK FANP
UNLOCK FANP

NAME=RACK:0..7/FANP:0..7;

Command Tree:
MANAGED-ELEMENT h BSS-EQUIPMENT h BTSEP h RACK h FANP h
UNLOCK FANP
Applicability:
Phase 2 and Phase 3.
Visibility level: 1.
Command Description:
This command changes the administrative state of the FANP unit of the BTSE.
Long Names:
NAME

Address of the managed object

System Responses:
Operation Completed
The specified change of administrative state has been perfomed:
JOB: 141
PC Time&Date: 12:01:28 03/23/2005
NE Time&Date: 13:03:03 09/15/2004
USER NAME:

User_t

COMMAND:

Unlock FANP:NAME=RACK:0/FANP:0;

SW RELEASE:

01-04-17-01-26-51_05-02-23

COMMAND RESULT: Operation successful


administrativeState = Unlocked
END OF OUTPUT FOR JOB 141

A50016-G5100-B333-04-7619

Id:0900d80580595994

437

FANP

BS-4x / 82 II / 240 / 241 / 240XL commands

CHANGED STATE EVENT REPORT:


This provides information about the administrative state, the operational state and the
availability status every time a state change occurs:
JOB: 142
PC Time&Date: 12:01:28 03/23/2005
NE Time&Date: 13:03:03 09/15/2004
USER NAME:

User_t

SW RELEASE:

01-04-17-01-26-51_05-02-23

COMMAND RESULT: Operation successful


CHANGED STATE EVENT REPORT:
NAME = RACK:0/FANP:0
Administrative State = UNLOCKED
Notification Identifier = 340
END OF OUTPUT FOR JOB 142
Operation Failed
The specified change of administrative state has not been performed.
Application Guidelines:

After locking of the FANP, the FANP will still be in operation, but in the administrative
state Locked

Example of Command Execution:


Unlock FANP:NAME=RACK:0/FANP:0;

438

Id:0900d80580595994

A50016-G5100-B333-04-7619

BS-4x / 82 II / 240 / 241 / 240XL commands

FCUMAIN

FCUMAIN
The FlexCU board is modeled with three HMO instances: 1 instance of the FCUMAIN
HMO and 2 instances of the FCUTR HMO. The FCUMAIN instance represents that part
of the board which performs board related activities and the FCUTR instances represent
carrier (TRX) specific activities. There is a dependency of the FCUTR instances towards
the FCUMAIN instance of a FlexCU.

CREATE FCUMAIN
CREATE FCUMAIN

NAME=RACK:0..7/FCUMAIN:0..11 [,FCUMODE=] [,RXLEVADJ=] [,RXLEVADJN1D1=] [,TCC=];

Command Tree:
MANAGED-ELEMENT h BSS-EQUIPMENT h BTSEP h RACK h FCUMAIN h
CREATE FCUMAIN
Applicability:
Phase 2 and Phase 3.
Visibility level: 2.
Command Description:
This command adds the FCUMAIN unit to the BTSE data base.
Long Names:
NAME

Address of the managed object

FCUMODE

fcuMode

RXLEVADJ

rxLevAdjust(dB)

RXLEVADJN1D1
TCC

rxLevAdjustN1D1(dB)

txCoherentComb

System Responses:
Operation Completed
After command execution, a message of Changed Configuration Notification is displayed.
A further message indicates the result of the operation. An example of create command
is the following:
JOB: 56
PC Time&Date: 16:34:31 03/23/2005
NE Time&Date: 16:32:25 09/15/2004
USER NAME:

user_Eberhard

COMMAND:
Create FCUMAIN:NAME=RACK:0/FCUMAIN:0,FCUMODE=singleCUMode,RXLEVADJ=1-1,RXLEVADJN1D1=1-1;

A50016-G5100-B333-04-7619

Id:0900d80580595996

439

FCUMAIN

BS-4x / 82 II / 240 / 241 / 240XL commands

SW RELEASE:

01-04-17-01-26-51_05-02-23

COMMAND RESULT: Operation successful

ChangedConfigurationNotification:
name = RACK:0/FCUMAIN:0
ChangeInfo = created
M
END OF OUTPUT FOR JOB 56
JOB: 57
PC Time&Date: 16:34:31 03/23/2005
NE Time&Date: 16:32:25 09/15/2004
USER NAME:

user_Eberhard

COMMAND: Create FCUMAIN:NAME=RACK:0/FCUMAIN:0,FCUMODE=singleCUMode,RXLEVADJ=1-1,RXLEVADJN1D1=1-1;


SW RELEASE:

01-04-17-01-26-51_05-02-23

COMMAND RESULT: Operation successful


fcuMode = singleCUMode
rxLevAdjust(dB) =
adjustValue = 1.0
adjustDivValue = 1.0
rxLevAdjustN1D1(dB) =
adjustValueN1 = 1.0
adjustDivValueD1 = 1.0
END OF OUTPUT FOR JOB 57
Operation Failed
The specified Object has not been created. In addition to the general NACK causes, a
specific NACK cause, which indicates that the command is inconsistent with the
physical configuration, is possible. An example is the following:
JOB: 76
PC Time&Date: 16:37:54 03/23/2005
NE Time&Date: 16:35:47 09/15/2004

440

Id:0900d80580595996

A50016-G5100-B333-04-7619

BS-4x / 82 II / 240 / 241 / 240XL commands

USER NAME:

FCUMAIN

user_Eberhard

COMMAND:
Create FCUMAIN:NAME=RACK:0/FCUMAIN:0,FCUMODE=singleCUMode,RXLEVADJ=1-1,RXLEVADJN1D1=1-1;
SW RELEASE:

01-04-17-01-26-51_05-02-23

COMMAND RESULT: Operation failed

fcuMode = singleCUMode
rxLevAdjust(dB) =
adjustValue = 1.0
adjustDivValue = 1.0
rxLevAdjustN1D1(dB) =
adjustValueN1 = 1.0
adjustDivValueD1 = 1.0
message cannot be performed (-17)
END OF OUTPUT FOR JOB 76
Application Guidelines:
None.
Example of Command Execution:
Create FCUMAIN: NAME=RACK:0/FCUMAIN:0,FCUMODE=singleCUMode,
RXLEVADJ-20,RXLEVADJN1D1-20;

DELETE FCUMAIN
DELETE FCUMAIN

NAME=RACK:0..7/FCUMAIN:0..11;

Command Tree:
MANAGED-ELEMENT h BSS-EQUIPMENT h BTSEP h RACK h FCUMAIN h
DELETE FCUMAIN
Applicability:
Phase 2 and Phase 3.
Visibility level: 2.
Command Description:
This command deletes the FCUMAIN unit from the BTSE data base.
Long Names:
NAME

Address of the managed object

System Responses:
Operation Completed

A50016-G5100-B333-04-7619

Id:0900d80580595996

441

FCUMAIN

BS-4x / 82 II / 240 / 241 / 240XL commands

After command execution, a message of Changed Configuration Notification is displayed. A further message indicates the result of the operation. An example of delete
command is the following:
JOB: 66
PC Time&Date: 16:35:23 03/23/2005
NE Time&Date: 16:33:17 09/15/2004
USER NAME:

user_Eberhard

SW RELEASE:

01-04-17-01-26-51_05-02-23

COMMAND RESULT: Operation successful


ChangedConfigurationNotification:
name = RACK:0/FCUMAIN:0
ChangeInfo = deleted
END OF OUTPUT FOR JOB 66
JOB: 67
PC Time&Date: 16:35:23 03/23/2005
NE Time&Date: 16:33:17 09/15/2004
USER NAME:

user_Eberhard

COMMAND:

Delete FCUMAIN:NAME=RACK:0/FCUMAIN:0;

SW RELEASE:

01-04-17-01-26-51_05-02-23

COMMAND RESULT: Operation successful


END OF OUTPUT FOR JOB 67
Operation Failed
The specified Object has not been deleted. Additionally to the general NACK causes, a
specific NACK cause, meaning that the command is inconsistent with physical configuration, is possible.
Application Guidelines:
None.
Example of Command Execution:
Delete FCUMAIN:NAME=RACK:0/FCUMAIN:0;

442

Id:0900d80580595996

A50016-G5100-B333-04-7619

BS-4x / 82 II / 240 / 241 / 240XL commands

FCUMAIN

GET FCUMAIN
GET FCUMAIN

NAME=RACK:0..7/FCUMAIN:0..11 [,REQATTL=ALS, AST,


AVS, BSWVER, FCUMODE, OST, PRS, RELFUNCOBJ,
RXLEVADJ, RXLEVADJN1D1, FPGAFWVER, TCC];

Command Tree:
MANAGED-ELEMENT h BSS-EQUIPMENT h BTSEP h RACK h FCUMAIN h
GET FCUMAIN
Applicability:
Phase 2 and Phase 3.
Visibility level: 0.
Command Description:
This command displays the attributes of the FCUMAIN unit of the BTSE.
Long Names:
NAME

Address of the managed object

REQATTL

Required attribute list

ALS

alarmStatus

AST

administrativeState

AVS

availabilityStatus

BSWVER

bootSoftwareVersion

FCUMODE

fcuMode

OST

operationalState

PRS

proceduralStatus

RELFUNCOBJ
RXLEVADJ

relatedFuncObjects
rxLevAdjust(dB)

RXLEVADJN1D1
FPGAFWVER
TCC

rxLevAdjustN1D1(dB)

fpgaFwVer
txCoherentComb

System Responses:
Operation Completed
A message indicates the result of the operation. An example of get command is the following:
JOB: 8
PC Time&Date: 26.06.2008 11:13:56 +02:00
NE Time&Date: 01.01.1990 00:13:20 +00:00
USER NAME:

A50016-G5100-B333-04-7619

user_Eberhard

Id:0900d80580595996

443

FCUMAIN

BS-4x / 82 II / 240 / 241 / 240XL commands

COMMAND:

Get FCUMAIN:NAME=RACK:0/FCUMAIN:1;

SW RELEASE:

01-04-19-01-09-01_08-06-23

COMMAND RESULT: Operation successful


alarmStatus = CLEARED
administrativeState = Unlocked
availabilityStatus = NULL
bootSoftwareVersion = ""
fcuMode = doubleCUMode
operationalState = DISABLED
proceduralStatus = initializing
relatedFuncObjects = Null
rxLevAdjust(dB) =
adjustValue = 0.0
adjustDivValue = 0.0
rxLevAdjustN1D1(dB) =
adjustValueN1 = 0.0
adjustDivValueD1 = 0.0
END OF OUTPUT FOR JOB 8
Operation Failed
The GET command has not been successfully executed. A general NACK will indicate
possible errors or a specific NACK strictly related to the single command is possible.
Application Guidelines:

FPGAFWVER attribute identifier cannot be present in the listOfRequiredAttributes


together with other attribute identifiers and it is not sent by the BTSE if a Get FCUMAIN/Get CU is done without the information element listOfRequiredAttributes

Example of Command Execution:


Get FCUMANIN:NAME=RACK:0/FTNFP:0,REQATTL=ALS&AST&AVS&BSWVER&
FCUMODE&OST&PRS&RELFUNCOBJ& RXLEVADJ&RXLEVADJN1D1&TCC;

GET FCUMAIN FWID


GET FCUMAIN FWID

NAME=RACK:0..7/FCUMAIN:0..11;

Command Tree:
MANAGED-ELEMENT h BSS-EQUIPMENT h BTSEP h RACK h FCUMAIN h
GET FCUMAIN FWID
Applicability:
Phase 2 and Phase 3.
Visibility level: 0.

444

Id:0900d80580595996

A50016-G5100-B333-04-7619

BS-4x / 82 II / 240 / 241 / 240XL commands

FCUMAIN

Command Description:
This command provides information on the FPGA FW images that are contained in the
boards flash prom together with an indication of the active version.
Up to 4 images are provided per board.
For FlexCUv2 or ECUv6 boards the FPGA FW versions are provided together with an
indication whether the FW version is the active one.
Long Names:
NAME

Address of the managed object

REQATTL

Required attribute list

System Responses:
Operation Completed
JOB: 9
PC Time&Date: 26.06.2008 11:14:02 +02:00
NE Time&Date: 01.01.1990 00:13:26 +00:00
USER NAME:

user_Eberhard

COMMAND:

Get FCUMAIN FWID:NAME=RACK:0/FCUMAIN:1;

SW RELEASE:

01-04-19-01-09-01_08-06-23

COMMAND RESULT:

Operation successful

fpgaFwVer = Null
END OF OUTPUT FOR JOB 9
Operation Failed
None.
Application Guidelines:
None.
Example of Command Execution:
Get FCUMAIN FWID:NAME=RACK:0/FCUMAIN:1, REQATTL=FPGAFWVER;

GET FCUMAIN WIRING


GET FCUMAIN WIRING NAME=RACK:0..7/FCUMAIN:0..11;
Command Tree:
MANAGED-ELEMENT h BSS-EQUIPMENT h BTSEP h RACK h FCUMAIN h
GET FCUMAIN WIRING
Applicability:
Phase 2 and Phase 3.

A50016-G5100-B333-04-7619

Id:0900d80580595996

445

FCUMAIN

BS-4x / 82 II / 240 / 241 / 240XL commands

Visibility level: 0.
Command Description:
This command displays the attributes of the FCUMAIN unit of the BTSE.
Long Names:
NAME

Address of the managed object

REQATTL

Required attribute list

System Responses:
Operation Completed
After command execution, a message of Changed Configuration Notification is displayed. A further message indicates the result of the operation. An example of create
command is the following:
JOB: 221
PC Time&Date: 12:13:58 03/23/2005
NE Time&Date: 13:15:33 09/15/2004
USER NAME:

user_Eberhard

COMMAND:

Get FCUMAIN WIRING:NAME=RACK:0/FCUMAIN:1;

SW RELEASE:
cessful

01-04-17-01-26-51_05-02-23COMMAND RESULT: Operation suc-

fcumainWiring =
variable
END OF OUTPUT FOR JOB 221
Operation Failed
The GET command has not been successfully executed. A general NACK will indicate
possible errors or a specific NACK strictly related to the single command is possible.
Application Guidelines:
Refer to FCUMAINWIRING
Example of Command Execution:
Get FCUMAIN WIRING:NAME=RACK:0/FCUMAIN:0;

GETTEST FCUMAIN
GETTEST FCUMAIN

446

NAME=RACK:0..7/FCUMAIN:0..11;

Id:0900d80580595996

A50016-G5100-B333-04-7619

BS-4x / 82 II / 240 / 241 / 240XL commands

FCUMAIN

Command Tree:
MANAGED-ELEMENT h BSS-EQUIPMENT h BTSEP h RACK h FCUMAIN h
GETTEST FCUMAIN
Applicability:
Phase 2 and Phase 3.
Visibility level: 0.
Command Description:
This command displays the attributes of the FCUMAIN test.
Long Names:
NAME

Address of the managed object

REQATTL

Required attribute list

System Responses:
Operation Completed
A message indicates the result of the operation. An example of gettest command is the
following:
JOB: 221
PC Time&Date: 12:13:58 03/23/2005
NE Time&Date: 13:15:33 09/15/2004
USER NAME:

user_Eberhard

COMMAND:

Gettest FCUMAIN:NAME=RACK:0/FCUMAIN:0;

SW RELEASE:

01-04-17-01-26-51_05-02-23

COMMAND RESULT: Operation successful


MOT = RACK:0/FCUMAIN:0
testMonitor =
phaseId = PreliminaryTestsFCUMAIN
phaseStatus = Running
phaseId = CheckAlarmStatusFCUMAIN
phaseStatus = Waiting
phaseId = EndTestFCUMAIN
phaseStatus = Waiting
testOutcome = INCONCLUSIVE
testState = INITIALIZING
END OF OUTPUT FOR JOB 221

A50016-G5100-B333-04-7619

Id:0900d80580595996

447

FCUMAIN

BS-4x / 82 II / 240 / 241 / 240XL commands

Operation Failed
The GET command has not been successfully executed. A general NACK will indicate
possible errors or a specific NACK strictly related to the single command is possible.
testMonitor
phaseId =
phaseStatus =

it is a list of all test phases related to the


selected object; for each phase the
related phaseStatus is provided (Passed,
Failed, Running or Waiting).

phaseId =
phaseStatus =
...
...
testOutcome

It represents the test result: it can be


Inconclusive (if the phases already
executed were successful) or Fail (if at
least one of the executed phases failed).

testState = Testing

It can assume one of the following values:


not_initialized, idle, initializing, suspended, testing, terminating and disabled.

Application Guidelines:
None.
Example of Command Execution:
Gettest FCUMAIN:NAME=RACK:0/FCUMAIN:0;

LOCK FCUMAIN
LOCK FCUMAIN

NAME=RACK:0..7/FCUMAIN:0..11;

Command Tree:
MANAGED-ELEMENT h BSS-EQUIPMENT h BTSEP h RACK h FCUMAIN h
LOCK FCUMAIN
Applicability:
Phase 2 and Phase 3.
Visibility level: 1.
Command Description:
This command changes the administrative state of the FCUMAIN object of the BTSE.
Long Names:
NAME

Address of the managed object

System Responses:
Operation Completed
The specified change of administrative state has been perfomed:

448

Id:0900d80580595996

A50016-G5100-B333-04-7619

BS-4x / 82 II / 240 / 241 / 240XL commands

FCUMAIN

JOB: 60
PC Time&Date: 16:35:08 03/23/2005
NE Time&Date: 16:33:02 09/15/2004
USER NAME:

user_Eberhard

COMMAND:

Lock FCUMAIN:NAME=RACK:0/FCUMAIN:0;

SW RELEASE:

01-04-17-01-26-51_05-02-23

COMMAND RESULT: Operation successful


administrativeState = Locked
END OF OUTPUT FOR JOB 60

CHANGED STATE EVENT REPORT:


This provides information about the administrative state, the operational state and the
availability status every time a state change occurs:
JOB: 61
PC Time&Date: 16:35:08 03/23/2005
NE Time&Date: 16:33:02 09/15/2004
USER NAME:

user_Eberhard

SW RELEASE:

01-04-17-01-26-51_05-02-23

COMMAND RESULT: Operation successful


CHANGED STATE EVENT REPORT:
NAME = RACK:0/FCUMAIN:0
Administrative State = LOCKED
Notification Identifier = 494
END OF OUTPUT FOR JOB 61
Operation Failed
The specified change of administrative state has not been performed.

A50016-G5100-B333-04-7619

Id:0900d80580595996

449

FCUMAIN

BS-4x / 82 II / 240 / 241 / 240XL commands

Application Guidelines:
While a Frequency Redefinition procedure is ongoing, the lock/unlock of all HMO's
actually related to a TRX is forbidden because that could lead to minor SELIC problem
or major SELIC problem alarms.
Example of Command Execution:
Lock FCUMAIN:NAME=RACK:0/FCUMANIN:0

PERFTEST FCUMAIN
PERFTEST FCUMAIN

NAME=RACK:0..7/FCUMAIN:0..11;

Command Tree:
MANAGED-ELEMENT h BSS-EQUIPMENT h BTSEP h RACK h FCUMAIN h
PERFTEST FCUMAIN
Applicability:
Phase 2 and Phase 3.
Visibility level: 1.
Command Description:
This command is used to start an asynchronous test in FCUMAIN .
Long Names:
NAME

Address of the managed object

System Responses:
Operation Completed
Test configuration has been set and the specified test has been started. The System
response will not be addressed to the MOT but to the object BTSEP.
JOB: 222
PC Time&Date: 12:14:01 03/23/2005
NE Time&Date: 13:15:36 09/15/2004
USER NAME:

user_Eberhard

COMMAND:

Perftest FCUMAIN:NAME=RACK:0/FCUMAIN:0;

SW RELEASE:

01-04-17-01-26-51_05-02-23

COMMAND RESULT: Operation successful


MOT = RACK:0/FCUMAIN:0
tO = BTSETEST:6
END OF OUTPUT FOR JOB 222

450

Id:0900d80580595996

A50016-G5100-B333-04-7619

BS-4x / 82 II / 240 / 241 / 240XL commands

FCUMAIN

JOB: 223
PC Time&Date: 12:14:01 03/23/2005
NE Time&Date: 13:15:36 09/15/2004
USER NAME:

user_Eberhard

SW RELEASE:

01-04-17-01-26-51_05-02-23

COMMAND RESULT: Operation successful


ChangedConfigurationNotification:
name = BTSETEST:6
ChangeInfo = created
END OF OUTPUT FOR JOB 223
JOB: 224
PC Time&Date: 12:14:01 03/23/2005
NE Time&Date: 13:15:36 09/15/2004
USER NAME:

user_Eberhard

SW RELEASE:

01-04-17-01-26-51_05-02-23

COMMAND RESULT: Operation successful


CHANGED STATE EVENT REPORT:
NAME = RACK:0/FCUMAIN:0
Operational State = ENABLED
Availability Status = NULL_value
Notification Identifier = 139
END OF OUTPUT FOR JOB 224

JOB: 225

A50016-G5100-B333-04-7619

Id:0900d80580595996

451

FCUMAIN

BS-4x / 82 II / 240 / 241 / 240XL commands

PC Time&Date: 12:14:01 03/23/2005


NE Time&Date: 13:15:36 09/15/2004
USER NAME:

user_Eberhard

SW RELEASE:

01-04-17-01-26-51_05-02-23

COMMAND RESULT: Operation successful


Test Report:
name = BTSETEST:6
testOutcome = PASSED
testTermination = Normal
MOT = RACK:0/FCUMAIN:0
executedPhases =
PreliminaryTestsFCUMAIN
CheckAlarmStatusFCUMAIN
EndTestFCUMAIN
END OF OUTPUT FOR JOB 225
JOB: 226
PC Time&Date: 12:14:01 03/23/2005
NE Time&Date: 13:15:36 09/15/2004
USER NAME:

user_Eberhard

SW RELEASE:

01-04-17-01-26-51_05-02-23

COMMAND RESULT: Operation successful


ChangedConfigurationNotification:
name = BTSETEST:6
ChangeInfo = deleted
END OF OUTPUT FOR JOB 226
The test results will be displayed at the end of the test phases.
Result TEST:
name =

452

TEST:<n>

Id:0900d80580595996

A50016-G5100-B333-04-7619

BS-4x / 82 II / 240 / 241 / 240XL commands

FCUMAIN

testOutcome =

This field represents the test result; one of the following values can be displayed:
Pass

all the test phases are successfully


performed.

Inconclusive

the test is aborted by the system or


the test is terminated by the operator.

Fail

if at least one of the executed phases


fail.

mOts =

It is the identifier of the hardware object under test.

testTermination =

It specifies how the test is terminated, it can assume


the following values:
Normal

all the test phases are performed.

Abort

the test is aborted by system.

Cancel

the test is terminated by operator.

executedPhases
phaseId =
additionalWords =
....

It represents the list of the executed test phases (in


case of successful test result, all the test phases will
be listed).

failedPhases
phaseId =

It represents the list of the failed test phase; additional information is provided for each phase.

phaseId =
....
skippedPhases
phaseId =

It represents the list of the skipped phases; they are


displayed only for test stopped during it execution.

phaseId =
....
poprosedRepair Action
=

A list of most probable fail probable causes is shown


(max four messages)

Operation Failed
This NACK-message occurs in the following cases: message cannot be performed, test
not supported, capacity restrictions, physical configuration cannot be performed, object
not locked.
Application Guidelines:
None.
Example of Command Execution:
Perftest FCUMAIN:NAME=RACK:0/FCUMANIN:0

A50016-G5100-B333-04-7619

Id:0900d80580595996

453

FCUMAIN

BS-4x / 82 II / 240 / 241 / 240XL commands

SET FCUMAIN
SET FCUMAIN

NAME=RACK:0..7/FCUMAIN:0..11 [,RXLEVADJ=]
[,RXLEVADJN1D1=] [,TCC=];

Command Tree:
MANAGED-ELEMENT h BSS-EQUIPMENT h BTSEP h RACK h FCUMAIN h
SET FCUMAIN
Applicability:
Phase 2 and Phase 3.
Visibility level: 2.
Command Description:
This command is used to set the attributes of the specified FCUMAIN .
Long Names:
NAME

Address of the managed object

RXLEVADJ

rxLevAdjust(dB)

RXLEVADJN1D1
TCC

rxLevAdjustN1D1(dB)

txCoherentComb

System Responses:
Operation Completed
After command execution, a message of Changed Attribute Event Report is displayed.
A further message indicates the result of the operation. An example of set command is
the following:
JOB: 176
PC Time&Date: 12:05:36 03/23/2005
NE Time&Date: 13:07:12 09/15/2004
USER NAME:

user_Eberhard

COMMAND:

Set FCUMAIN:NAME=RACK:0/FCUMAIN:0;

SW RELEASE:

01-04-17-01-26-51_05-02-23

COMMAND RESULT: Operation successful


END OF OUTPUT FOR JOB 176
Operation Failed
The specified attributes have not been set. In addition to the general NACK causes, a
specific NACK cause, which indicates that the command is inconsistent with the
physical configuration, is possible.

454

Id:0900d80580595996

A50016-G5100-B333-04-7619

BS-4x / 82 II / 240 / 241 / 240XL commands

FCUMAIN

Application Guidelines:
None.
Example of Command Execution:
Set FCUMAIN:NAME=RACK:0/FCUMANIN:0,RXLEVADJ=-2,RXLEVADJN1D1=-2

STOPTEST FCUMAIN
STOPTEST FCUMAIN

NAME=RACK:0..7/FCUMAIN:0..11;

Command Tree:
MANAGED-ELEMENT h BSS-EQUIPMENT h BTSEP h RACK h FCUMAIN h
STOPTEST FCUMAIN
Applicability:
Phase 2 and Phase 3.
Visibility level: 1.
Command Description:
This command is used to stop a diagnostic previously started.
Long Names:
NAME

Address of the managed object

System Responses:
Operation Completed
Test has been stopped. The System Responses will not be addressed to the MOT but
to the object BTSEP.

Result TEST:
name =

TEST:<n>

testOutcome =

inconclusive

mOts =

It is the identifier of the hardware object under test.

testTermination =

Cancel

executedPhases
phaseId =

It represents the list of the executed test phases; the


list is not shown for test in the waiting list (queued).

...
.
failedPhases
phaseId =

It represents the list of the failed test phase;

phaseId =

additional information is provided for each phase.

....
skippedPhases

A50016-G5100-B333-04-7619

Id:0900d80580595996

455

FCUMAIN

BS-4x / 82 II / 240 / 241 / 240XL commands

phaseId =

It represents the list of the skipped phases;the list is


not shown for test in the waiting list (queued).

phaseId =
Operation Failed

Test has not been stopped. This NACK-message can occur when the specified test is
not running or in case of test which cannot be stopped.
Application Guidelines:
None.
Example of Command Execution:
Stoptest FCUMAIN:NAME=RACK:0/FCUMANIN:0;

UNLOCK FCUMAIN
UNLOCK FCUMAIN

NAME=RACK:0..7/FCUMAIN:0..11;

Command Tree:
MANAGED-ELEMENT h BSS-EQUIPMENT h BTSEP h RACK h FCUMAIN h
UNLOCK FCUMAIN
Applicability:
Phase 2 and Phase 3.
Visibility level: 1.
Command Description:
This command changes the administrative state of the FCUMAIN object of the BTSE.
Long Names:
NAME

Address of the managed object

System Responses:
Operation Completed
The specified change of administrative state has been perfomed:
JOB: 62
PC Time&Date: 16:35:12 03/23/2005
NE Time&Date: 16:33:06 09/15/2004
USER NAME:

user_Eberhard

COMMAND:

Unlock FCUMAIN:NAME=RACK:0/FCUMAIN:0;

SW RELEASE:

01-04-17-01-26-51_05-02-23

COMMAND RESULT: Operation successful


administrativeState = Unlocked

456

Id:0900d80580595996

A50016-G5100-B333-04-7619

BS-4x / 82 II / 240 / 241 / 240XL commands

FCUMAIN

END OF OUTPUT FOR JOB 62

CHANGED STATE EVENT REPORT:


This provides information about the administrative state, the operational state and the
availability status every time a state change occurs:
JOB: 63
PC Time&Date: 16:35:12 03/23/2005
NE Time&Date: 16:33:06 09/15/2004
USER NAME:

user_Eberhard

SW RELEASE:

01-04-17-01-26-51_05-02-23

COMMAND RESULT: Operation successful


CHANGED STATE EVENT REPORT:
NAME = RACK:0/FCUMAIN:0
Administrative State = UNLOCKED
Notification Identifier = 495
END OF OUTPUT FOR JOB 63
Operation Failed
The specified change of administrative state has not been performed.
Application Guidelines:
While a Frequency Redefinition procedure is ongoing, the lock/unlock of all HMO's
actually related to a TRX is forbidden because that could lead to minor SELIC problem
or major SELIC problem alarms.
Example of Command Execution:
Unlock FCUMAIN:NAME=RACK:0/FCUMANIN:0;

A50016-G5100-B333-04-7619

Id:0900d80580595996

457

FCUTR

BS-4x / 82 II / 240 / 241 / 240XL commands

FCUTR
The FlexCU board is modeled with three HMO instances: 1 instance of the FCUMAIN
HMO and 2 instances of the FCUTR HMO. The FCUMAIN instance represents that part
of the board which performs board related activities and the FCUTR instances represent
carrier (TRX) specific activities. There is a dependency of the FCUTR instances towards
the FCUMAIN instance of a FlexCU.

CREATE FCUTR
CREATE FCUTR

NAME=RACK:0..7/FCUTR:0..23 [,TXLEVADJ=];

Command Tree:
MANAGED-ELEMENT h BSS-EQUIPMENT h BTSEP h RACK h FCUTR h
CREATE FCUTR
Applicability:
Phase 2 and Phase 3.
Visibility level: 2.
Command Description:
This command adds the FCUTR unit to the BTSE data base.
Long Names:
NAME

Address of the managed object

TXLEVADJ

txLevAdjust(dB)

System Responses:
Operation Completed
After command execution, a message of Changed Configuration Notification is displayed.
A further message indicates the result of the operation. An example of create command
is the following:
JOB: 56
PC Time&Date: 16:34:31 03/23/2005
NE Time&Date: 16:32:25 09/15/2004
USER NAME:

user_Frank

SW RELEASE:

01-04-17-01-26-51_05-02-23

COMMAND RESULT: Operation successful


ChangedConfigurationNotification:

458

Id:0900d80580595998

A50016-G5100-B333-04-7619

BS-4x / 82 II / 240 / 241 / 240XL commands

FCUTR

name = RACK:0/FCUTR:0
ChangeInfo = created
END OF OUTPUT FOR JOB 56
JOB: 57
PC Time&Date: 16:34:31 03/23/2005
NE Time&Date: 16:32:25 09/15/2004
USER NAME:

user_Frank

COMMAND:

Create FCUTR:NAME=RACK:0/FCUTR:0,TXLEVADJ=1;

SW RELEASE:

01-04-17-01-26-51_05-02-23

COMMAND RESULT: Operation successful


txLevAdjust(dB) = 1.0
END OF OUTPUT FOR JOB 57
Operation Failed
The specified Object has not been created. In addition to the general NACK causes, a
specific NACK cause, which indicates that the command is inconsistent with the
physical configuration, is possible. An example is the following:
JOB: 76
PC Time&Date: 16:37:54 03/23/2005
NE Time&Date: 16:35:47 09/15/2004
USER NAME:

user_Frank

COMMAND:

Create FCUTR:NAME=RACK:0/FCUTR:0,TXLEVADJ=1;

SW RELEASE:

01-04-17-01-26-51_05-02-23

COMMAND RESULT: Operation failed


txLevAdjust(dB) = 1.0
Creation out of sequence (-162)
END OF OUTPUT FOR JOB 76
Application Guidelines:
None.

A50016-G5100-B333-04-7619

Id:0900d80580595998

459

FCUTR

BS-4x / 82 II / 240 / 241 / 240XL commands

Example of Command Execution:


Create FCUTR:NAME=RACK:0/FCUTR:0,TXLEVADJ=-20;

DELETE FCUTR
DELETE FCUTR

NAME=RACK:0..7/FCUTR:0..23;

Command Tree:
MANAGED-ELEMENT h BSS-EQUIPMENT h BTSEP h RACK h FCUTR h
DELETE FCUTR
Applicability:
Phase 2 and Phase 3.
Visibility level: 2.
Command Description:
This command deletes the FCUTR unit from the BTSE data base.
Long Names:
NAME

Address of the managed object

System Responses:
Operation Completed
After command execution, a message of Changed Configuration Notification is displayed. A further message indicates the result of the operation. An example of delete
command is the following:
JOB: 66
PC Time&Date: 16:35:23 03/23/2005
NE Time&Date: 16:33:17 09/15/2004
USER NAME:

user_Frank

SW RELEASE:

01-04-17-01-26-51_05-02-23

COMMAND RESULT: Operation successful


ChangedConfigurationNotification:
name = RACK:0/FCUTR:0
ChangeInfo = deleted
END OF OUTPUT FOR JOB 66
JOB: 67

460

Id:0900d80580595998

A50016-G5100-B333-04-7619

BS-4x / 82 II / 240 / 241 / 240XL commands

FCUTR

PC Time&Date: 16:35:23 03/23/2005


NE Time&Date: 16:33:17 09/15/2004
USER NAME:

user_Frank

COMMAND:

Delete FCUTR:NAME=RACK:0/FCUTR:0;

SW RELEASE:

01-04-17-01-26-51_05-02-23

COMMAND RESULT: Operation successful


END OF OUTPUT FOR JOB 67
Operation Failed
The specified Object has not been deleted. Additionally to the general NACK causes, a
specific NACK cause, meaning that the command is inconsistent with physical configuration, is possible.
Application Guidelines:
None.
Example of Command Execution:
Delete FCUTR:NAME=RACK:0/FCUTR:0;

GET FCUTR
GET FCUTR

NAME=RACK:0..7/FCUTR:0..23 [,REQATTL=ALS, AST,


AVS, CCPBL, OST, OUTPUTPR, PRS, RELFUNCOBJ,
TXLEVADJ, STDBYST];

Command Tree:
MANAGED-ELEMENT h BSS-EQUIPMENT h BTSEP h RACK h FCUTR h
GET FCUTR
Applicability:
Phase 2 and Phase 3.
Visibility level: 0.
Command Description:
This command displays the attributes of the FCUTR unit of the BTSE.
Long Names:
NAME

Address of the managed object

REQATTL

Required attribute list

ALS

alarmStatus

AST

administrativeState

AVS

availabilityStatus

CCPBL

carrierCapability

A50016-G5100-B333-04-7619

Id:0900d80580595998

461

FCUTR

BS-4x / 82 II / 240 / 241 / 240XL commands

OST

operationalState

OUTPUTPR

outputPowerReduction

PRS

proceduralStatus

RELFUNCOBJ

relatedFuncObjects

TXLEVADJ

txLevAdjust(dB)

STDBYST

standbyStatus

System Responses:
Operation Completed
A message indicates the result of the operation. An example of GETcommand is the following:
JOB: 59
PC Time&Date: 16:34:52 03/23/2005
NE Time&Date: 16:32:46 09/15/2004
USER NAME: user_Frank
COMMAND: Get FCUTR:NAME=RACK:0/FCUTR:0;
SW RELEASE: 01-04-17-01-26-51_05-02-23
COMMAND RESULT:Operation successful
alarmStatus = CLEARED
administrativeState = Unlocked
availabilityStatus = NULL
carrierCapability = edgeFourRxDiv
operationalState = ENABLED
outputPowerReduction = db0
proceduralStatus = NULL
relatedFuncObjects =
FMO = BTS:2/TRX:6
standbyStatus = ColdStandBy
txLevAdjust(dB) = 0.0
END OF OUTPUT FOR JOB 59
Operation Failed
The GET command has not been successfully executed. A general NACK will indicate
possible errors or a specific NACK strictly related to the single command is possible.
Application Guidelines:
None.
Example of Command Execution:
Get FCUTR:NAME=RACK:0/FCUTR:0,REQATTL=ALS&AST&AVS& CCPBL&OUTPUTPR&OST&PRS&RELFUNCOBJ& TXLEVADJ;

462

Id:0900d80580595998

A50016-G5100-B333-04-7619

BS-4x / 82 II / 240 / 241 / 240XL commands

FCUTR

GETTEST FCUTR
GETTEST FCUTR

NAME=RACK:0..7/FCUTR:0..23;

Command Tree:
MANAGED-ELEMENT h BSS-EQUIPMENT h BTSEP h RACK h FCUTR h
GETTEST FCUTR
Applicability:
Phase 2 and Phase 3.
Visibility level: 0.
Command Description:
This command displays the attributes of the FCUTR test.
Long Names:
NAME

Address of the managed object

REQATTL

Required attribute list

System Responses:
Operation Completed
A message indicates the result of the operation. An example of gettest command is the
following:
JOB: 221
PC Time&Date: 12:13:58 03/23/2005
NE Time&Date: 13:15:33 09/15/2004
USER NAME:

user_Frank

COMMAND:

Gettest FCUTR:NAME=RACK:0/FCUTR:0;

SW RELEASE:

01-04-17-01-26-51_05-02-23

COMMAND RESULT: Operation successful


MOT = RACK:0/FTNFP:0
testMonitor =
phaseId = PreliminaryTestsFCUTR
phaseStatus = Running
phaseId = CheckAlarmStatusFCUTR
phaseStatus = Waiting
phaseId = EndTestFCUTR
phaseStatus = Waiting
testOutcome = INCONCLUSIVE
testState = INITIALIZING

A50016-G5100-B333-04-7619

Id:0900d80580595998

463

FCUTR

BS-4x / 82 II / 240 / 241 / 240XL commands

END OF OUTPUT FOR JOB 221


Operation Failed
The GET command has not been successfully executed. A general NACK will indicate
possible errors or a specific NACK strictly related to the single command is possible.
testMonitor
phaseId =
phaseStatus =

it is a list of all test phases related to the


selected object; for each phase the
related phaseStatus is provided (Passed,
Failed, Running or Waiting).

phaseId =
phaseStatus =
...
...
testOutcome

It represents the test result: it can be


Inconclusive (if the phases already
executed were successful) or Fail (if at
least one of the executed phases failed).

testState = Testing

It can assume one of the following values:


not_initialized, idle, initializing, suspended, testing, terminating and disabled.

Application Guidelines:
None.
Example of Command Execution:
Gettest FCUTR:NAME=RACK:0/FCUTR:0;

LOCK FCUTR
LOCK FCUTR

NAME=RACK:0..7/FCUTR:0..23;

Command Tree:
MANAGED-ELEMENT h BSS-EQUIPMENT h BTSEP h RACK h FCUTR h
LOCK FCUTR
Applicability:
Phase 2 and Phase 3.
Visibility level: 1.
Command Description:
This command changes the administrative state of the FCUTR object of the BTSE.
Long Names:
NAME

464

Address of the managed object

Id:0900d80580595998

A50016-G5100-B333-04-7619

BS-4x / 82 II / 240 / 241 / 240XL commands

FCUTR

System Responses:
Operation Completed
The specified change of administrative state has been perfomed:
JOB: 60
PC Time&Date: 16:35:08 03/23/2005
NE Time&Date: 16:33:02 09/15/2004
USER NAME:

user_Frank

COMMAND:

Lock FCUTR:NAME=RACK:0/FCUTR:0;

SW RELEASE:

01-04-17-01-26-51_05-02-23

COMMAND RESULT: Operation successful


administrativeState = Locked
END OF OUTPUT FOR JOB 60

CHANGED STATE EVENT REPORT:


This provides information about the administrative state, the operational state and the
availability status every time a state change occurs:
JOB: 61
PC Time&Date: 16:35:08 03/23/2005
NE Time&Date: 16:33:02 09/15/2004
USER NAME:

user_Frank

SW RELEASE:

01-04-17-01-26-51_05-02-23

COMMAND RESULT: Operation successful


CHANGED STATE EVENT REPORT:
NAME = RACK:0/FCUTR:0
Administrative State = LOCKED
Notification Identifier = 494
END OF OUTPUT FOR JOB 61

A50016-G5100-B333-04-7619

Id:0900d80580595998

465

FCUTR

BS-4x / 82 II / 240 / 241 / 240XL commands

Operation Failed
The specified change of administrative state has not been performed.
Application Guidelines:
While a Frequency Redefinition procedure is ongoing, the lock/unlock of all HMO's
actually related to a TRX is forbidden because that could lead to minor SELIC problem
or major SELIC problem alarms.
Example of Command Execution:
Lock FCUTR:NAME=RACK:0/FCUTR:0;

PERFTEST FCUTR
PERFTEST FCUTR

NAME=RACK:0..7/FCUTR:0..23;

Command Tree:
MANAGED-ELEMENT h BSS-EQUIPMENT h BTSEP h RACK h FCUTR h
PERFTEST FCUTR
Applicability:
Phase 2 and Phase 3.
Visibility level: 1.
Command Description:
This command is used to start an asynchronous test in FCUTR.
Long Names:
NAME

Address of the managed object

System Responses:
Operation Completed
Test configuration has been set and the specified test has been started. The System
response will not be addressed to the MOT but to the object BTSEP.
JOB: 222
PC Time&Date: 12:14:01 03/23/2005
NE Time&Date: 13:15:36 09/15/2004
USER NAME:

user_Frank

COMMAND:

Perftest FCUTR:NAME=RACK:0/FCUTR:0;

SW RELEASE:

01-04-17-01-26-51_05-02-23

COMMAND RESULT: Operation successful


MOT = RACK:0/FCUTR:0
tO = BTSETEST:6

466

Id:0900d80580595998

A50016-G5100-B333-04-7619

BS-4x / 82 II / 240 / 241 / 240XL commands

FCUTR

END OF OUTPUT FOR JOB 222

JOB: 223
PC Time&Date: 12:14:01 03/23/2005
NE Time&Date: 13:15:36 09/15/2004
USER NAME:

user_Frank

SW RELEASE:

01-04-17-01-26-51_05-02-23

COMMAND RESULT: Operation successful


ChangedConfigurationNotification:
name = BTSETEST:6
ChangeInfo = created
END OF OUTPUT FOR JOB 223
JOB: 224
PC Time&Date: 12:14:01 03/23/2005
NE Time&Date: 13:15:36 09/15/2004
USER NAME:

user_Frank

SW RELEASE:

01-04-17-01-26-51_05-02-23

COMMAND RESULT: Operation successful


CHANGED STATE EVENT REPORT:
NAME = RACK:0/FCUTR:0
Operational State = ENABLED
Availability Status = NULL_value
Notification Identifier = 139
END OF OUTPUT FOR JOB 224

A50016-G5100-B333-04-7619

Id:0900d80580595998

467

FCUTR

BS-4x / 82 II / 240 / 241 / 240XL commands

JOB: 225
PC Time&Date: 12:14:01 03/23/2005
NE Time&Date: 13:15:36 09/15/2004
USER NAME:

user_Frank

SW RELEASE:

01-04-17-01-26-51_05-02-23

COMMAND RESULT: Operation successful


Test Report:
name = BTSETEST:6
testOutcome = PASSED
testTermination = Normal
MOT = RACK:0/FCUTR:0
executedPhases =
PreliminaryTestsFCUTR
CheckAlarmStatusFCUTR
EndTestFCUTR
END OF OUTPUT FOR JOB 225
JOB: 226
PC Time&Date: 12:14:01 03/23/2005
NE Time&Date: 13:15:36 09/15/2004
USER NAME:

user_Frank

SW RELEASE:

01-04-17-01-26-51_05-02-23

COMMAND RESULT: Operation successful


ChangedConfigurationNotification:
name = BTSETEST:6
ChangeInfo = deleted
END OF OUTPUT FOR JOB 226
The test results will be displayed at the end of the test phases.

468

Id:0900d80580595998

A50016-G5100-B333-04-7619

BS-4x / 82 II / 240 / 241 / 240XL commands

FCUTR

Result TEST:
name =

TEST:<n>

testOutcome =

This field represents the test result; one of the following values can be displayed:
Pass

all the test phases are successfully


performed.

Inconclusive

the test is aborted by the system or


the test is terminated by the operator.

Fail

if at least one of the executed phases


fail.

mOts =

It is the identifier of the hardware object under test.

testTermination =

It specifies how the test is terminated, it can assume


the following values:
Normal

all the test phases are performed.

Abort

the test is aborted by system.

Cancel

the test is terminated by operator.

executedPhases
phaseId =
additionalWords =
....

It represents the list of the executed test phases (in


case of successful test result, all the test phases will
be listed).

failedPhases
phaseId =

It represents the list of the failed test phase; additional information is provided for each phase.

phaseId =
....
skippedPhases
phaseId =

It represents the list of the skipped phases; they are


displayed only for test stopped during it execution.

phaseId =
....
poprosedRepair Action
=

A list of most probable fail probable causes is shown


(max four messages)

Operation Failed
This NACK-message occurs in the following cases: message cannot be performed, test
not supported, capacity restrictions, physical configuration cannot be performed, object
not locked.
Application Guidelines:
None.

A50016-G5100-B333-04-7619

Id:0900d80580595998

469

FCUTR

BS-4x / 82 II / 240 / 241 / 240XL commands

Example of Command Execution:


Perftest FCUTR:NAME=RACK:0/FCUTR:0;

SET FCUTR
SET FCUTR

NAME=RACK:0..7/FCUTR:0..23 [,TXLEVADJ=];

Command Tree:
MANAGED-ELEMENT h BSS-EQUIPMENT h BTSEP h RACK h FCUTR h
SET FCUTR
Applicability:
Phase 2 and Phase 3.
Visibility level: 2.
Command Description:
This command is used to set the attributes of the specified RACK.
Long Names:
NAME

Address of the managed object

TXLEVADJ

txLevAdjust(dB)

System Responses:
Operation Completed
After command execution, a message of Changed Attribute Event Report is displayed.
A further message indicates the result of the operation. An example of set command is
the following:
JOB: 176
PC Time&Date: 12:05:36 03/23/2005
NE Time&Date: 13:07:12 09/15/2004
USER NAME:

user_Frank

COMMAND:

Set FCUTR:NAME=RACK:0/FCUTR:0;

SW RELEASE:

01-04-17-01-26-51_05-02-23

COMMAND RESULT: Operation successful


END OF OUTPUT FOR JOB 176
Operation Failed
The specified attributes have not been set. In addition to the general NACK causes, a
specific NACK cause, which indicates that the command is inconsistent with the
physical configuration, is possible.

470

Id:0900d80580595998

A50016-G5100-B333-04-7619

BS-4x / 82 II / 240 / 241 / 240XL commands

FCUTR

Application Guidelines:
None.
Example of Command Execution:
Set FCUTR:NAME=RACK:0/FCUTR:0;

STOPTEST FCUTR
STOPTEST FCUTR

NAME=RACK:0..7/FCUTR:0..23;

Command Tree:
MANAGED-ELEMENT h BSS-EQUIPMENT h BTSEP h RACK h FCUTR h
STOPTEST FCUTR
Applicability:
Phase 2 and Phase 3.
Visibility level: 1.
Command Description:
This command is used to stop a diagnostic previously started.
Long Names:
NAME

Address of the managed object

System Responses:
Operation Completed
Test has been stopped. The System Responses will not be addressed to the MOT but
to the object BTSEP.

Result TEST:
name =

TEST:<n>

testOutcome =

inconclusive

mOts =

It is the identifier of the hardware object under test.

testTermination =

Cancel

executedPhases
phaseId =

It represents the list of the executed test phases; the


list is not shown for test in the waiting list (queued).

...
.
failedPhases
phaseId =

It represents the list of the failed test phase;

phaseId =

additional information is provided for each phase.

....
skippedPhases

A50016-G5100-B333-04-7619

Id:0900d80580595998

471

FCUTR

BS-4x / 82 II / 240 / 241 / 240XL commands

phaseId =

It represents the list of the skipped phases;the list is


not shown for test in the waiting list (queued).

phaseId =
Operation Failed

Test has not been stopped. This NACK-message can occur when the specified test is
not running or in case of test which cannot be stopped.
Application Guidelines:
None.
Example of Command Execution:
Stoptest FCUTR:NAME=RACK:0/FCUTR:0;

UNLOCK FCUTR
UNLOCK FCUTR

NAME=RACK:0..7/FCUTR:0..23;

Command Tree:
MANAGED-ELEMENT h BSS-EQUIPMENT h BTSEP h RACK h FCUTR h
UNLOCK FCUTR
Applicability:
Phase 2 and Phase 3.
Visibility level: 1.
Command Description:
This command changes the administrative state of the FCUTR object of the BTSE.
Long Names:
NAME

Address of the managed object

System Responses:
Operation Completed
The specified change of administrative state has been perfomed:
JOB: 62
PC Time&Date: 16:35:12 03/23/2005
NE Time&Date: 16:33:06 09/15/2004
USER NAME:

user_Frank

COMMAND:

Unlock FCUTR:NAME=RACK:0/FCUTR:0;

SW RELEASE:

01-04-17-01-26-51_05-02-23

COMMAND RESULT: Operation successful


administrativeState = Unlocked

472

Id:0900d80580595998

A50016-G5100-B333-04-7619

BS-4x / 82 II / 240 / 241 / 240XL commands

FCUTR

END OF OUTPUT FOR JOB 62

CHANGED STATE EVENT REPORT:


This provides information about the administrative state, the operational state and the
availability status every time a state change occurs:
JOB: 63
PC Time&Date: 16:35:12 03/23/2005
NE Time&Date: 16:33:06 09/15/2004
USER NAME:

user_Frank

SW RELEASE:

01-04-17-01-26-51_05-02-23

COMMAND RESULT: Operation successful


CHANGED STATE EVENT REPORT:
NAME = RACK:0/FCUTR:0
Administrative State = UNLOCKED
Notification Identifier = 495
END OF OUTPUT FOR JOB 63
Operation Failed
The specified change of administrative state has not been performed.
Application Guidelines:
While a Frequency Redefinition procedure is ongoing, the lock/unlock of all HMO's
actually related to a TRX is forbidden because that could lead to minor SELIC problem
or major SELIC problem alarms.
Example of Command Execution:
Unlock FCUTR:NAME=RACK:0/FCUTR:0;

A50016-G5100-B333-04-7619

Id:0900d80580595998

473

FTNFP

BS-4x / 82 II / 240 / 241 / 240XL commands

FTNFP
The FTNFP object represents the hardware of the tunable filters in the dowlink direction
(from BTS to MS).

CREATE FTNFP
CREATE FTNFP

NAME=RACK:0..7/FTNFP:0..7 ,CELLNO= ,WDFTNFP=;

Command Tree:
MANAGED-ELEMENT h BSS-EQUIPMENT h BTSEP h RACK h FTNFP h
CREATE FTNFP
Applicability:
Phase 2 and Phase 3.
Visibility level: 2.
Command Description:
This command adds the FICOM_TNF unit to the BTSE data base.
Long Names:
NAME

Address of the managed object

CELLNO

cellNumber

WDFTNFP

wiringDataFtnfp

System Responses:
Operation Completed
After command execution, a message of Changed Configuration Notification is displayed.
A further message indicates the result of the operation. An example of create command
is the following:
JOB: 56
PC Time&Date: 16:34:31 03/23/2005
NE Time&Date: 16:32:25 09/15/2004
USER NAME:

user_v

SW RELEASE:

01-04-17-01-26-51_05-02-23

COMMAND RESULT: Operation successful


ChangedConfigurationNotification:
name = RACK:0/FTNFP:0
ChangeInfo = created

474

Id:0900d8058059599a

A50016-G5100-B333-04-7619

BS-4x / 82 II / 240 / 241 / 240XL commands

FTNFP

END OF OUTPUT FOR JOB 56


JOB: 57
PC Time&Date: 16:34:31 03/23/2005
NE Time&Date: 16:32:25 09/15/2004
USER NAME:

user_v

COMMAND:
Create FTNFP:NAME=RACK:0/FTNFP:0,CELLNO=1,WDFTNFP=CU0-FVSWRP0;
SW RELEASE:

01-04-17-01-26-51_05-02-23

COMMAND RESULT: Operation successful


cellNumber = 1
wiringDataFtnfp =
CUWiring = CU0
FVSWRPWiring = FVSWRP0
END OF OUTPUT FOR JOB 57
Operation Failed
The specified Object has not been created. In addition to the general NACK causes, a
specific NACK cause, which indicates that the command is inconsistent with the
physical configuration, is possible. An example is the following:
JOB: 76
PC Time&Date: 16:37:54 03/23/2005
NE Time&Date: 16:35:47 09/15/2004
USER NAME:

user_v

COMMAND:
Create FTNFP:NAME=RACK:0/FTNFP:0,CELLNO=1,WDFTNFP=CU0-FVSWRP0;
SW RELEASE:

01-04-17-01-26-51_05-02-23

COMMAND RESULT: OPERATION FAILED


message cannot be performed (-17)
END OF OUTPUT FOR JOB 76

A50016-G5100-B333-04-7619

Id:0900d8058059599a

475

FTNFP

BS-4x / 82 II / 240 / 241 / 240XL commands

Application Guidelines:

The FICOM_TNFP, the CU and the FICOM_VSWRP are in the same rack and
belong to the same cell

Creation of FTNFP:i is rejected if DUAMCO:(i/2) is created

Example of Command Execution:


Create FTNFP:NAME=RACK:0/FTNFP:0,CELLNO=0,WDFTNFP=CU0-FVSWRP0;

DELETE FTNFP
DELETE FTNFP

NAME=RACK:0..7/FTNFP:0..7;

Command Tree:
MANAGED-ELEMENT h BSS-EQUIPMENT h BTSEP h RACK h FTNFP h
DELETE FTNFP
Applicability:
Phase 2 and Phase 3.
Visibility level: 2.
Command Description:
This command deletes the FICOM_TNF unit from the BTSE data base.
Long Names:
NAME

Address of the managed object

System Responses:
Operation Completed
After command execution, a message of Changed Configuration Notification is displayed. A further message indicates the result of the operation. An example of delete
command is the following:
JOB: 66
PC Time&Date: 16:35:23 03/23/2005
NE Time&Date: 16:33:17 09/15/2004
USER NAME:

user_v

SW RELEASE:

01-04-17-01-26-51_05-02-23

COMMAND RESULT: Operation successful


ChangedConfigurationNotification:
name = RACK:0/FTNFP:0
ChangeInfo = deleted

476

Id:0900d8058059599a

A50016-G5100-B333-04-7619

BS-4x / 82 II / 240 / 241 / 240XL commands

FTNFP

END OF OUTPUT FOR JOB 66


JOB: 67
PC Time&Date: 16:35:23 03/23/2005
NE Time&Date: 16:33:17 09/15/2004
USER NAME:

user_v

COMMAND:

Delete FTNFP:NAME=RACK:0/FTNFP:0;

SW RELEASE:

01-04-17-01-26-51_05-02-23

COMMAND RESULT: Operation successful


END OF OUTPUT FOR JOB 67
Operation Failed
The specified Object has not been deleted. Additionally to the general NACK causes, a
specific NACK cause, meaning that the command is inconsistent with physical configuration, is possible.
Application Guidelines:

FTNFP must be locked in Phase 3, before deletion

If this object is deleted, the related TRX is out of service

Example of Command Execution:


Delete FTNFP:NAME=RACK:0/FTNFP:0;

GET FTNFP
GET FTNFP

NAME=RACK:0..7/FTNFP:0..7 [,REQATTL=ALS, AST,


AVS, CELLNO, OST, PRS, RELFUNCOBJ, TNFTARGF,
WDFTNFP];

Command Tree:
MANAGED-ELEMENT h BSS-EQUIPMENT h BTSEP h RACK h FTNFP h
GET FTNFP
Applicability:
Phase 2 and Phase 3.
Visibility level: 0.
Command Description:
This command displays the attributes of the FICOM_TNF unit of the BTSE.
Long Names:
NAME

A50016-G5100-B333-04-7619

Address of the managed object

Id:0900d8058059599a

477

FTNFP

BS-4x / 82 II / 240 / 241 / 240XL commands

REQATTL

Required attribute list

ALS

alarmStatus

AST

administrativeState

AVS

availabilityStatus

CELLNO

cellNumber

OST

operationalState

PRS

proceduralStatus

RELFUNCOBJ

relatedFuncObjects

TNFTARGF

tnfTargetFrequency

WDFTNFP

wiringDataFtnfp

System Responses:
Operation Completed
A message indicates the result of the operation. An example of get command is the following:
JOB: 59
PC Time&Date: 16:34:52 03/23/2005
NE Time&Date: 16:32:46 09/15/2004
USER NAME:

user_v

COMMAND:

Get FTNFP:NAME=RACK:0/FTNFP:0;

SW RELEASE:

01-04-17-01-26-51_05-02-23

COMMAND RESULT: Operation successful


alarmStatus = CLEARED
administrativeState = Unlocked
availabilityStatus = NotInstalled
cellNumber = 1
operationalState = DISABLED
proceduralStatus = NULL
relatedFuncObjects =
tnfTargetFrequency = Null
wiringDataFtnfp =
CUWiring = CU0
FVSWRPWiring = FVSWRP0
END OF OUTPUT FOR JOB 59
Operation Failed

478

Id:0900d8058059599a

A50016-G5100-B333-04-7619

BS-4x / 82 II / 240 / 241 / 240XL commands

FTNFP

The GET command has not been successfully executed. A general NACK will indicate
possible errors or a specific NACK strictly related to the single command is possible.
Application Guidelines:

The value for the attribute relatedFuncObjects in LMT Evolution Phase 2 is "not configured"

Example of Command Execution:


Get FTNFP:NAME=RACK:0/FTNFP:0,REQATTL=ALS&AST&AVS&CELLNO&
RELFUNCOBJ&OST&PRS&TNFTARGF&WDFTNFP;

GETTEST FTNFP
GETTEST FTNFP

NAME=RACK:0..7/FTNFP:0..7;

Command Tree:
MANAGED-ELEMENT h BSS-EQUIPMENT h BTSEP h RACK h FTNFP h
GETTEST FTNFP
Applicability:
Phase 2 and Phase 3.
Visibility level: 0.
Command Description:
This command displays the attributes of the FTNFP test.
Long Names:
NAME

Address of the managed object

REQATTL

Required attribute list

System Responses:
Operation Completed
A message indicates the result of the operation. An example of gettest command is the
following:
JOB: 221
PC Time&Date: 12:13:58 03/23/2005
NE Time&Date: 13:15:33 09/15/2004
USER NAME:

user_v

COMMAND:

Gettest FTNFP:NAME=RACK:0/FTNFP:0;

SW RELEASE:

01-04-17-01-26-51_05-02-23

COMMAND RESULT: Operation successful


MOT = RACK:0/FTNFP:0

A50016-G5100-B333-04-7619

Id:0900d8058059599a

479

FTNFP

BS-4x / 82 II / 240 / 241 / 240XL commands

testMonitor =
phaseId = PreliminaryTestsFtnfp
phaseStatus = Running
phaseId = CheckAlarmStatusFtnfp
phaseStatus = Waiting
phaseId = EndTestFtnfp
phaseStatus = Waiting
testOutcome = INCONCLUSIVE
testState = INITIALIZING
END OF OUTPUT FOR JOB 221
Operation Failed
The GET command has not been successfully executed. A general NACK will indicate
possible errors or a specific NACK strictly related to the single command is possible.
testMonitor
phaseId =
phaseStatus =

it is a list of all test phases related to the


selected object; for each phase the
related phaseStatus is provided (Passed,
Failed, Running or Waiting).

phaseId =
phaseStatus =
...
...
testOutcome

It represents the test result: it can be


Inconclusive (if the phases already
executed were successful) or Fail (if at
least one of the executed phases failed).

testState = Testing

It can assume one of the following values:


not_initialized, idle, initializing, suspended, testing, terminating and disabled.

Application Guidelines:
None.
Example of Command Execution:
Gettest FTNFP:NAME=RACK:0/FTNFP:0;

LOCK FTNFP
LOCK FTNFP

NAME=RACK:0..7/FTNFP:0..7;

Command Tree:
MANAGED-ELEMENT h BSS-EQUIPMENT h BTSEP h RACK h FTNFP h
LOCK FTNFP

480

Id:0900d8058059599a

A50016-G5100-B333-04-7619

BS-4x / 82 II / 240 / 241 / 240XL commands

FTNFP

Applicability:
Phase 2 and Phase 3.
Visibility level: 1.
Command Description:
This command changes the administrative state of the FICOM_TNF object of the BTSE.
Long Names:
NAME

Address of the managed object

System Responses:
Operation Completed
The specified change of administrative state has been perfomed:
JOB: 60
PC Time&Date: 16:35:08 03/23/2005
NE Time&Date: 16:33:02 09/15/2004
USER NAME:

user_v

COMMAND:

Lock FTNFP:NAME=RACK:0/FTNFP:0;

SW RELEASE:

01-04-17-01-26-51_05-02-23

COMMAND RESULT: Operation successful


administrativeState = Locked
END OF OUTPUT FOR JOB 60

CHANGED STATE EVENT REPORT:


This provides information about the administrative state, the operational state and the
availability status every time a state change occurs:
JOB: 61
PC Time&Date: 16:35:08 03/23/2005
NE Time&Date: 16:33:02 09/15/2004
USER NAME:

user_v

SW RELEASE:

01-04-17-01-26-51_05-02-23

COMMAND RESULT: Operation successful

A50016-G5100-B333-04-7619

Id:0900d8058059599a

481

FTNFP

BS-4x / 82 II / 240 / 241 / 240XL commands

CHANGED STATE EVENT REPORT:


NAME = RACK:0/FTNFP:0
Administrative State = LOCKED
Notification Identifier = 494
END OF OUTPUT FOR JOB 61
Operation Failed
The specified change of administrative state has not been performed.
Application Guidelines:
While a Frequency Redefinition procedure is ongoing, the lock/unlock of all HMO's
actually related to a TRX is forbidden because that could lead to minor SELIC problem
or major SELIC problem alarms.
Example of Command Execution:
Lock FTNFP:NAME=RACK:0/FTNFP:0

PERFTEST FTNFP
PERFTEST FTNFP

NAME=RACK:0..7/FTNFP:0..7;

Command Tree:
MANAGED-ELEMENT h BSS-EQUIPMENT h BTSEP h RACK h FTNFP h
PERFTEST FTNFP
Applicability:
Phase 2 and Phase 3.
Visibility level: 1.
Command Description:
This command is used to start an asynchronous test in FTNFP.
Long Names:
NAME

Address of the managed object

System Responses:
Operation Completed
Test configuration has been set and the specified test has been started. The System
response will not be addressed to the MOT but to the object BTSEP.
JOB: 222
PC Time&Date: 12:14:01 03/23/2005
NE Time&Date: 13:15:36 09/15/2004

482

Id:0900d8058059599a

A50016-G5100-B333-04-7619

BS-4x / 82 II / 240 / 241 / 240XL commands

FTNFP

USER NAME:

user_v

COMMAND:

Perftest FTNFP:NAME=RACK:0/FTNFP:0;

SW RELEASE:

01-04-17-01-26-51_05-02-23

COMMAND RESULT: Operation successful


MOT = RACK:0/FTNFP:0
tO = BTSETEST:6
END OF OUTPUT FOR JOB 222

JOB: 223
PC Time&Date: 12:14:01 03/23/2005
NE Time&Date: 13:15:36 09/15/2004
USER NAME:

user_v

SW RELEASE:

01-04-17-01-26-51_05-02-23

COMMAND RESULT: Operation successful


ChangedConfigurationNotification:
name = BTSETEST:6
ChangeInfo = created
END OF OUTPUT FOR JOB 223
JOB: 224
PC Time&Date: 12:14:01 03/23/2005
NE Time&Date: 13:15:36 09/15/2004
USER NAME:

user_v

SW RELEASE:

01-04-17-01-26-51_05-02-23

COMMAND RESULT: Operation successful


CHANGED STATE EVENT REPORT:

A50016-G5100-B333-04-7619

Id:0900d8058059599a

483

FTNFP

BS-4x / 82 II / 240 / 241 / 240XL commands

NAME = RACK:0/FTNFP:0
Operational State = ENABLED
Availability Status = NULL_value
Notification Identifier = 139
END OF OUTPUT FOR JOB 224

JOB: 225
PC Time&Date: 12:14:01 03/23/2005
NE Time&Date: 13:15:36 09/15/2004
USER NAME:

user_v

SW RELEASE:

01-04-17-01-26-51_05-02-23

COMMAND RESULT: Operation successful


Test Report:
name = BTSETEST:6
testOutcome = PASSED
testTermination = Normal
MOT = RACK:0/FTNFP:0
executedPhases =
PreliminaryTestsFtnfp
CheckAlarmStatusFtnfp
EndTestFtnfp
END OF OUTPUT FOR JOB 225
JOB: 226
PC Time&Date: 12:14:01 03/23/2005
NE Time&Date: 13:15:36 09/15/2004
USER NAME:

user_v

SW RELEASE:

01-04-17-01-26-51_05-02-23

COMMAND RESULT: Operation successful

484

Id:0900d8058059599a

A50016-G5100-B333-04-7619

BS-4x / 82 II / 240 / 241 / 240XL commands

FTNFP

ChangedConfigurationNotification:
name = BTSETEST:6
ChangeInfo = deleted
END OF OUTPUT FOR JOB 226
The test results will be displayed at the end of the test phases.
Result TEST:
name =

TEST:<n>

testOutcome =

This field represents the test result; one of the following values can be displayed:
Pass

all the test phases are successfully


performed.

Inconclusive

the test is aborted by the system or


the test is terminated by the operator.

Fail

if at least one of the executed phases


fail.

mOts =

It is the identifier of the hardware object under test.

testTermination =

It specifies how the test is terminated, it can assume


the following values:
Normal

all the test phases are performed.

Abort

the test is aborted by system.

Cancel

the test is terminated by operator.

executedPhases
phaseId =
additionalWords =
....

It represents the list of the executed test phases (in


case of successful test result, all the test phases will
be listed).

failedPhases
phaseId =

It represents the list of the failed test phase; additional information is provided for each phase.

phaseId =
....
skippedPhases
phaseId =

It represents the list of the skipped phases; they are


displayed only for test stopped during it execution.

phaseId =
....
poprosedRepair Action
=

A50016-G5100-B333-04-7619

A list of most probable fail probable causes is shown


(max four messages)

Id:0900d8058059599a

485

FTNFP

BS-4x / 82 II / 240 / 241 / 240XL commands

Operation Failed
This NACK-message occurs in the following cases: message cannot be performed, test
not supported, capacity restrictions, physical configuration cannot be performed, object
not locked.
Application Guidelines:

In phase 3 MO must be locked previous to the command execution

Example of Command Execution:


Perftest FTNFP:NAME=RACK:0/FTNFP:0;

STOPTEST FTNFP
STOPTEST FTNFP

NAME=RACK:0..7/FTNFP:0..7;

Command Tree:
MANAGED-ELEMENT h BSS-EQUIPMENT h BTSEP h RACK h FTNFP h
STOPTEST FTNFP
Applicability:
Phase 2 and Phase 3.
Visibility level: 1.
Command Description:
This command is used to stop a diagnostic previously started.
Long Names:
NAME

Address of the managed object

System Responses:
Operation Completed
Test has been stopped. The System Responses will not be addressed to the MOT but
to the object BTSEP.

Result TEST:
name =

TEST:<n>

testOutcome =

inconclusive

mOts =

It is the identifier of the hardware object under test.

testTermination =

Cancel

executedPhases
phaseId =
...
.

It represents the list of the executed test phases; the


list is not shown for test in the waiting list (queued).

failedPhases

486

Id:0900d8058059599a

A50016-G5100-B333-04-7619

BS-4x / 82 II / 240 / 241 / 240XL commands

FTNFP

phaseId =

It represents the list of the failed test phase;

phaseId =

additional information is provided for each phase.

....
skippedPhases
phaseId =

It represents the list of the skipped phases;the list is


not shown for test in the waiting list (queued).

phaseId =
Operation Failed

Test has not been stopped. This NACK-message can occur when the specified test is
not running or in case of test which cannot be stopped.
Application Guidelines:
None.
Example of Command Execution:
Stoptest FTNFP:NAME=RACK:0/FTNFP:0;

UNLOCK FTNFP
UNLOCK FTNFP

NAME=RACK:0..7/FTNFP:0..7;

Command Tree:
MANAGED-ELEMENT h BSS-EQUIPMENT h BTSEP h RACK h FTNFP h
UNLOCK FTNFP
Applicability:
Phase 2 and Phase 3.
Visibility level: 1.
Command Description:
This command changes the administrative state of the FICOM_TNF object of the BTSE.
Long Names:
NAME

Address of the managed object

System Responses:
Operation Completed
The specified change of administrative state has been perfomed:
JOB: 62
PC Time&Date: 16:35:12 03/23/2005
NE Time&Date: 16:33:06 09/15/2004
USER NAME:

A50016-G5100-B333-04-7619

user_v

Id:0900d8058059599a

487

FTNFP

BS-4x / 82 II / 240 / 241 / 240XL commands

COMMAND:

Unlock FTNFP:NAME=RACK:0/FTNFP:0;

SW RELEASE:

01-04-17-01-26-51_05-02-23

COMMAND RESULT: Operation successful


administrativeState = Unlocked
END OF OUTPUT FOR JOB 62

CHANGED STATE EVENT REPORT:


This provides information about the administrative state, the operational state and the
availability status every time a state change occurs:
JOB: 63
PC Time&Date: 16:35:12 03/23/2005
NE Time&Date: 16:33:06 09/15/2004
USER NAME:

user_v

SW RELEASE:

01-04-17-01-26-51_05-02-23

COMMAND RESULT: Operation successful


CHANGED STATE EVENT REPORT:
NAME = RACK:0/FTNFP:0
Administrative State = UNLOCKED
Notification Identifier = 495
END OF OUTPUT FOR JOB 63
Operation Failed
The specified change of administrative state has not been performed.
Application Guidelines:
While a Frequency Redefinition procedure is ongoing, the lock/unlock of all HMO's
actually related to a TRX is forbidden because that could lead to minor SELIC problem
or major SELIC problem alarms.
Example of Command Execution:
Unlock FTNFP:NAME=RACK:0/FTNFP:0;

488

Id:0900d8058059599a

A50016-G5100-B333-04-7619

BS-4x / 82 II / 240 / 241 / 240XL commands

FVSWRP

FVSWRP
The FVSWR object represents the hardware of the tunable filters in the dowlink direction (from BTS to MS). There is only one FVSWR per cell, which performs also some
functionalities common to the cell (e.g. alarm generation).

CREATE FVSWRP
CREATE FVSWRP

NAME=RACK:0..7/FVSWRP:0..3 ,CELLNO=;

Command Tree:
MANAGED-ELEMENT h BSS-EQUIPMENT h BTSEP h RACK h FVSWRP h
CREATE FVSWRP
Applicability:
Phase 2 and Phase 3.
Visibility level: 2.
Command Description:
This command adds the FICOM_VSWR unit to the BTSE data base.
Long Names:
NAME

Address of the managed object

CELLNO

cellNumber

System Responses:
Operation Completed
After command execution, a message of Changed Configuration Notification is displayed.
A further message indicates the result of the operation. An example of create command
is the following:
JOB: 40
PC Time&Date: 16:31:19 03/23/2005
NE Time&Date: 16:29:13 09/15/2004
USER NAME:

user_val

SW RELEASE:

01-04-17-01-26-51_05-02-23

COMMAND RESULT: Operation successful


ChangedConfigurationNotification:
name = RACK:0/FVSWRP:0
ChangeInfo = created

A50016-G5100-B333-04-7619

Id:0900d8058059599c

489

FVSWRP

BS-4x / 82 II / 240 / 241 / 240XL commands

END OF OUTPUT FOR JOB 40


JOB: 41
PC Time&Date: 16:31:19 03/23/2005
NE Time&Date: 16:29:13 09/15/2004
USER NAME:

user_val

COMMAND:

Create FVSWRP:NAME=RACK:0/FVSWRP:0,CELLNO=1;

SW RELEASE:

01-04-17-01-26-51_05-02-23

COMMAND RESULT: Operation successful


cellNumber = 1
END OF OUTPUT FOR JOB 41
Operation Failed
The specified Object has not been created. In addition to the general NACK causes, a
specific NACK cause, which indicates that the command is inconsistent with the
physical configuration, is possible. An example is the following:
JOB: 77
PC Time&Date: 16:37:54 03/23/2005
NE Time&Date: 16:35:47 09/15/2004
USER NAME:

user_val

COMMAND:

Create FVSWRP:NAME=RACK:0/FVSWRP:0,CELLNO=1;

SW RELEASE:

01-04-17-01-26-51_05-02-23

COMMAND RESULT: OPERATION FAILED


Object instance unknown (-9)
END OF OUTPUT FOR JOB 77
Application Guidelines:
Creation of FVSWRP:i is rejected if DUAMCO:i is created.
Example of Command Execution:
Create FVSWRP:NAME=RACK:0/FVSWRP:0,CELLNO=0;

490

Id:0900d8058059599c

A50016-G5100-B333-04-7619

BS-4x / 82 II / 240 / 241 / 240XL commands

FVSWRP

DELETE FVSWRP
DELETE FVSWRP

NAME=RACK:0..7/FVSWRP:0..3;

Command Tree:
MANAGED-ELEMENT h BSS-EQUIPMENT h BTSEP h RACK h FVSWRP h
DELETE FVSWRP
Applicability:
Phase 2 and Phase 3.
Visibility level: 2.
Command Description:
This command deletes the FICOM_VSWR unit from the BTSE data base.
Long Names:
NAME

Address of the managed object

System Responses:
Operation Completed
After command execution, a message of Changed Configuration Notification is displayed. A further message indicates the result of the operation. An example of delete
command is the following:
JOB: 51
PC Time&Date: 16:33:29 03/23/2005
NE Time&Date: 16:31:23 09/15/2004
USER NAME:

user_val

SW RELEASE:

01-04-17-01-26-51_05-02-23

COMMAND RESULT: Operation successful


ChangedConfigurationNotification:
name = RACK:0/FVSWRP:0
ChangeInfo = deleted
END OF OUTPUT FOR JOB 51
JOB: 52
PC Time&Date: 16:33:29 03/23/2005
NE Time&Date: 16:31:23 09/15/2004

A50016-G5100-B333-04-7619

Id:0900d8058059599c

491

FVSWRP

BS-4x / 82 II / 240 / 241 / 240XL commands

USER NAME:

user_val

COMMAND:

Delete FVSWRP:NAME=RACK:0/FVSWRP:0;

SW RELEASE:

01-04-17-01-26-51_05-02-23

COMMAND RESULT: Operation successful


END OF OUTPUT FOR JOB 52
Operation Failed
The specified Object has not been deleted. Additionally to the general NACK causes, a
specific NACK cause, meaning that the command is inconsistent with physical configuration, is possible.
Application Guidelines:

FVSWRP must be locked in Phase 3, before deletion

If this object is deleted, the related TRXs are out of service

Example of Command Execution:


Delete FVSWRP:NAME=RACK:0/FVSWRP:0;

GET FVSWRP
GET FVSWRP

NAME=RACK:0..7/FVSWRP:0..3 [,REQATTL=ALS, AST,


AVS, CELLNO, OST, PRS, RELFUNCOBJ];

Command Tree:
MANAGED-ELEMENT h BSS-EQUIPMENT h BTSEP h RACK h FVSWRP h
GET FVSWRP
Applicability:
Phase 2 and Phase 3.
Visibility level: 0.
Command Description:
This command displays the attributes of the FICOM_VSWR unit of the BTSE.
Long Names:
NAME

Address of the managed object

REQATTL

Required attribute list

ALS

alarmStatus

AST

administrativeState

AVS

availabilityStatus

CELLNO

cellNumber

OST

operationalState

PRS

proceduralStatus

RELFUNCOBJ

492

relatedFuncObjects

Id:0900d8058059599c

A50016-G5100-B333-04-7619

BS-4x / 82 II / 240 / 241 / 240XL commands

FVSWRP

System Responses:
Operation Completed
A message indicates the result of the operation. An example of get command is the following:
JOB: 43
PC Time&Date: 16:32:46 03/23/2005
NE Time&Date: 16:30:40 09/15/2004
USER NAME:

user_val

COMMAND:

Get FVSWRP:NAME=RACK:0/FVSWRP:0;

SW RELEASE:

01-04-17-01-26-51_05-02-23

COMMAND RESULT: Operation successful


alarmStatus = CLEARED
administrativeState = Unlocked
availabilityStatus = NotInstalled
cellNumber = 1
operationalState = DISABLED
proceduralStatus = NULL
relatedFuncObjects =
END OF OUTPUT FOR JOB 43
Operation Failed
The GET command has not been successfully executed. A general NACK will indicate
possible errors or a specific NACK strictly related to the single command is possible.
Application Guidelines:

The value for the attribute relatedFuncObjects in LMT Phase 2 is "not configured"

Example of Command Execution:


Get FVSWRP:NAME=RACK:0/FVSWRP:0,REQATTL=ALS&AST&AVS&CELLNO&
RELFUNCOBJ&OST&PRS;

GETTEST FVSWRP
GETTEST FVSWRP

NAME=RACK:0..7/FVSWRP:0..3;

Command Tree:
MANAGED-ELEMENT h BSS-EQUIPMENT h BTSEP h RACK h FVSWRP h
GETTEST FVSWRP

A50016-G5100-B333-04-7619

Id:0900d8058059599c

493

FVSWRP

BS-4x / 82 II / 240 / 241 / 240XL commands

Applicability:
Phase 2 and Phase 3.
Visibility level: 0.
Command Description:
This command displays the attributes of the FVSWRP test.
Long Names:
NAME

Address of the managed object

REQATTL

Required attribute list

System Responses:
Operation Completed
A message indicates the result of the operation. An example of gettest command is the
following:
JOB: 227
PC Time&Date: 12:14:01 03/23/2005
NE Time&Date: 13:15:36 09/15/2004
USER NAME:

user_val

COMMAND:

Gettest FVSWRP:NAME=RACK:0/FVSWRP:0;

SW RELEASE:

01-04-17-01-26-51_05-02-23

COMMAND RESULT: Operation successful


MOT = RACK:0/FVSWRP:0
testMonitor =
phaseId = PreliminaryTestsFvswrp
phaseStatus = Running
phaseId = CheckAlarmStatusFvswrp
phaseStatus = Waiting
phaseId = EndTestFvswrp
phaseStatus = Waiting
testOutcome = INCONCLUSIVE
testState = INITIALIZING
END OF OUTPUT FOR JOB 227
Operation Failed
The GET command has not been successfully executed. A general NACK will indicate
possible errors or a specific NACK strictly related to the single command is possible.

494

Id:0900d8058059599c

A50016-G5100-B333-04-7619

BS-4x / 82 II / 240 / 241 / 240XL commands

testMonitor
phaseId =
phaseStatus =

FVSWRP

it is a list of all test phases related to the


selected object; for each phase the
related phaseStatus is provided (Passed,
Failed, Running or Waiting).

phaseId =
phaseStatus =
...
...
testOutcome

It represents the test result: it can be


Inconclusive (if the phases already
executed were successful) or Fail (if at
least one of the executed phases failed).

testState = Testing

It can assume one of the following values:


not_initialized, idle, initializing, suspended, testing, terminating and disabled.

Application Guidelines:
None.
Example of Command Execution:
Gettest FVSWRP:NAME=RACK:0/FVSWRP:0;

LOCK FVSWRP
LOCK FVSWRP

NAME=RACK:0..7/FVSWRP:0..3;

Command Tree:
MANAGED-ELEMENT h BSS-EQUIPMENT h BTSEP h RACK h FVSWRP h
LOCK FVSWRP
Applicability:
Phase 2 and Phase 3.
Visibility level: 1.
Command Description:
This command changes the administrative state of FICOM_VSWR unit of the BTSE.
Long Names:
NAME

Address of the managed object

System Responses:
Operation Completed
The specified change of administrative state has been perfomed:
JOB: 45

A50016-G5100-B333-04-7619

Id:0900d8058059599c

495

FVSWRP

BS-4x / 82 II / 240 / 241 / 240XL commands

PC Time&Date: 16:33:14 03/23/2005


NE Time&Date: 16:31:08 09/15/2004
USER NAME:

user_val

COMMAND:

Lock FVSWRP:NAME=RACK:0/FVSWRP:0;

SW RELEASE:

01-04-17-01-26-51_05-02-23

COMMAND RESULT: Operation successful


administrativeState = Locked
END OF OUTPUT FOR JOB 45

CHANGED STATE EVENT REPORT:


This provides information about the administrative state, the operational state and the
availability status every time a state change occurs:
JOB: 46
PC Time&Date: 16:33:14 03/23/2005
NE Time&Date: 16:31:08 09/15/2004
USER NAME:

user_val

SW RELEASE:

01-04-17-01-26-51_05-02-23

COMMAND RESULT: Operation successful


CHANGED STATE EVENT REPORT:
NAME = RACK:0/FVSWRP:0
Administrative State = LOCKED
Notification Identifier = 487
END OF OUTPUT FOR JOB 46
Operation Failed
The specified change of administrative state has not been performed.

496

Id:0900d8058059599c

A50016-G5100-B333-04-7619

BS-4x / 82 II / 240 / 241 / 240XL commands

FVSWRP

Application Guidelines:
While a Frequency Redefinition procedure is ongoing, the lock/unlock of all HMO's
actually related to a TRX is forbidden because that could lead to minor SELIC problem
or major SELIC problem alarms.
Example of Command Execution:
Lock FVSWRP:NAME=RACK:0/FVSWRP:0;

PERFTEST FVSWRP
PERFTEST FVSWRP

NAME=RACK:0..7/FVSWRP:0..3;

Command Tree:
MANAGED-ELEMENT h BSS-EQUIPMENT h BTSEP h RACK h FVSWRP h
PERFTEST FVSWRP
Applicability:
Phase 2 and Phase 3.
Visibility level: 1.
Command Description:
This command is used to start an asynchronous test in FVSWRP.
Long Names:
NAME

Address of the managed object

System Responses:
Operation Completed
Test configuration has been set and the specified test has been started. The System
response will not be addressed to the MOT but to the object BTSEP.
JOB: 228
PC Time&Date: 12:14:07 03/23/2005
NE Time&Date: 13:15:42 09/15/2004
USER NAME:

user_val

COMMAND:

Perftest FVSWRP:NAME=RACK:0/FVSWRP:0;

SW RELEASE:

01-04-17-01-26-51_05-02-23

COMMAND RESULT: Operation successful


MOT = RACK:0/FVSWRP:0
tO = BTSETEST:1
END OF OUTPUT FOR JOB 228

A50016-G5100-B333-04-7619

Id:0900d8058059599c

497

FVSWRP

BS-4x / 82 II / 240 / 241 / 240XL commands

JOB: 229
PC Time&Date: 12:14:18 03/23/2005
NE Time&Date: 13:15:49 09/15/2004
USER NAME:

user_val

SW RELEASE:

01-04-17-01-26-51_05-02-23

COMMAND RESULT: Operation successful


ChangedConfigurationNotification:
name = BTSETEST:1
ChangeInfo = created
END OF OUTPUT FOR JOB 229
JOB: 230
PC Time&Date: 12:14:18 03/23/2005
NE Time&Date: 13:15:49 09/15/2004
USER NAME:

user_val

SW RELEASE:

01-04-17-01-26-51_05-02-23

COMMAND RESULT: Operation successful


CHANGED STATE EVENT REPORT:
NAME = RACK:0/FVSWRP:0
Operational State = ENABLED
Availability Status = NULL_value
Notification Identifier = 238
END OF OUTPUT FOR JOB 230

JOB: 231

498

Id:0900d8058059599c

A50016-G5100-B333-04-7619

BS-4x / 82 II / 240 / 241 / 240XL commands

FVSWRP

PC Time&Date: 12:14:23 03/23/2005


NE Time&Date: 13:15:52 09/15/2004
USER NAME:

user_val

SW RELEASE:

01-04-17-01-26-51_05-02-23

COMMAND RESULT: Operation successful


Test Report:
name = BTSETEST:1
testOutcome = PASSED
testTermination = Normal
MOT = RACK:0/FVSWRP:0
executedPhases =
PreliminaryTestsFvswrp
CheckAlarmStatusFvswrp
EndTestFvswrp
END OF OUTPUT FOR JOB 231
JOB: 232
PC Time&Date: 12:14:41 03/23/2005
NE Time&Date: 13:16:05 09/15/2004
USER NAME:

user_val

SW RELEASE:

01-04-17-01-26-51_05-02-23

COMMAND RESULT: Operation successful


ChangedConfigurationNotification:
name = BTSETEST:1
ChangeInfo = deleted
END OF OUTPUT FOR JOB 232
The test results will be displayed at the end of the test phases.
Result TEST:
name =

A50016-G5100-B333-04-7619

TEST:<n>

Id:0900d8058059599c

499

FVSWRP

BS-4x / 82 II / 240 / 241 / 240XL commands

testOutcome =

This field represents the test result; one of the following values can be displayed:
Pass

all the test phases are successfully


performed.

Inconclusive

the test is aborted by the system or


the test is terminated by the operator.

Fail

if at least one of the executed phases


fail.

mOts =

It is the identifier of the hardware object under test.

testTermination =

It specifies how the test is terminated, it can assume


the following values:
Normal

all the test phases are performed.

Abort

the test is aborted by system.

Cancel

the test is terminated by operator.

executedPhases
phaseId =
additionalWords =
....

It represents the list of the executed test phases (in


case of successful test result, all the test phases will
be listed).

failedPhases
phaseId =
phaseId =

It represents the list of the failed test phase; additional information is provided for each phase.

....
skippedPhases
phaseId =
phaseId =

It represents the list of the skipped phases; they are


displayed only for test stopped during it execution.

....
poprosedRepair Action
=

A list of most probable fail probable causes is shown


(max four messages)

Operation Failed
This NACK-message occurs in the following cases: message cannot be performed, test
not supported, capacity restrictions, physical configuration cannot be performed, object
not locked.
Application Guidelines

In phase 3 MO must be locked previous to the command execution

Example of Command Execution:


Perftest FVSWRP:NAME=RACK:0/FVSWRP:0;

500

Id:0900d8058059599c

A50016-G5100-B333-04-7619

BS-4x / 82 II / 240 / 241 / 240XL commands

FVSWRP

STOPTEST FVSWRP
STOPTEST FVSWRP

NAME=RACK:0..7/FVSWRP:0..3;

Command Tree:
MANAGED-ELEMENT h BSS-EQUIPMENT h BTSEP h RACK h FVSWRP h
STOPTEST FVSWRP
Applicability:
Phase 2 and Phase 3.
Visibility level: 1.
Command Description:
This command is used to stop a diagnostic previously started.
Long Names:
NAME

Address of the managed object

System Responses:
Operation Completed
Test has been stopped. The System Responses will not be addressed to the MOT but
to the object BTSEP.

Result TEST:
name =

TEST:<n>

testOutcome =

inconclusive

mOts =

It is the identifier of the hardware object under test.

testTermination =

Cancel

executedPhases
phaseId =

It represents the list of the executed test phases; the


list is not shown for test in the waiting list (queued).

...
.
failedPhases
phaseId =

It represents the list of the failed test phase;

phaseId =

additional information is provided for each phase.

....
skippedPhases
phaseId =
phaseId =

It represents the list of the skipped phases;the list is


not shown for test in the waiting list (queued).

Operation Failed
Test has not been stopped. This NACK-message can occur when the specified test is
not running or in case of test which cannot be stopped.

A50016-G5100-B333-04-7619

Id:0900d8058059599c

501

FVSWRP

BS-4x / 82 II / 240 / 241 / 240XL commands

Application Guidelines:
None.
Example of Command Execution:
Stoptest FVSWRP:NAME=RACK:0/FVSWRP:0;

UNLOCK FVSWRP
UNLOCK FVSWRP

NAME=RACK:0..7/FVSWRP:0..3;

Command Tree:
MANAGED-ELEMENT h BSS-EQUIPMENT h BTSEP h RACK h FVSWRP h
UNLOCK FVSWRP
Applicability:
Phase 2 and Phase 3.
Visibility level: 1.
Command Description:
This command changes the administrative state of FICOM_VSWR unit of the BTSE.
Long Names:
NAME

Address of the managed object

System Responses:
Operation Completed
The specified change of administrative state has been perfomed:
JOB: 47
PC Time&Date: 16:33:19 03/23/2005
NE Time&Date: 16:31:13 09/15/2004
USER NAME:

user_val

COMMAND:

Unlock FVSWRP:NAME=RACK:0/FVSWRP:0;

SW RELEASE:

01-04-17-01-26-51_05-02-23

COMMAND RESULT: Operation successful


administrativeState = Unlocked
END OF OUTPUT FOR JOB 47

CHANGED STATE EVENT REPORT:

502

Id:0900d8058059599c

A50016-G5100-B333-04-7619

BS-4x / 82 II / 240 / 241 / 240XL commands

FVSWRP

This provides information about the administrative state, the operational state and the
availability status every time a state change occurs:
JOB: 48
PC Time&Date: 16:33:19 03/23/2005
NE Time&Date: 16:31:13 09/15/2004
USER NAME:

user_val

SW RELEASE:

01-04-17-01-26-51_05-02-23

COMMAND RESULT: Operation successful


CHANGED STATE EVENT REPORT:
NAME = RACK:0/FVSWRP:0
Administrative State = UNLOCKED
Notification Identifier = 488
END OF OUTPUT FOR JOB 48
Operation Failed
The specified change of administrative state has not been performed.
Application Guidelines:
While a Frequency Redefinition procedure is ongoing, the lock/unlock of all HMO's
actually related to a TRX is forbidden because that could lead to minor SELIC problem
or major SELIC problem alarms.
Example of Command Execution:
Unlock FVSWRP:NAME=RACK:0/FVSWRP:0;

A50016-G5100-B333-04-7619

Id:0900d8058059599c

503

LAPDLE

BS-4x / 82 II / 240 / 241 / 240XL commands

LAPDLE
The LAPDLE object identifies the logical link used by the BTSEP to communicate with
the BSC for operational and maintenance purposes. The object LAPDLE on BTSEP
side is a HW object which correspond to the FMO LPDLM at BSC side. It is possible
configure in the BSC more than one LPDLM object for each BTSM object instance (up
to eight LPDLM links for each BTSM on the four PCMB lines, and the LAPD links are
either all 64 Kb/s or all 16 Kb/s, and either all satellited or all no satellited, for the same
BTSEP).

CREATE LAPDLE
CREATE LAPDLE

NAME=LAPDLE:0..10 ,LAPDCH=;

Command Tree:
MANAGED-ELEMENT h BSS-EQUIPMENT h BTSEP h LAPDLE h CREATE
LAPDLE
Applicability:
Phase 2 and Phase 3.
Visibility level: 2.
Command Description:
This command adds a LAPDLE object in the BTSE database.
Long Names:
NAME

Address of the managed object

LAPDCH

lapdChannel

System Responses:
Operation Completed
After command execution, a message of Changed Configuration Notification is displayed.
A further message indicates the result of the operation. An example of create command
is the following:
JOB: 150
PC Time&Date: 12:02:21 03/23/2005
NE Time&Date: 13:03:56 09/15/2004
USER NAME:

user_val1

SW RELEASE:

01-04-17-01-26-51_05-02-23

COMMAND RESULT: Operation successful


ChangedConfigurationNotification:

504

Id:0900d8058059599e

A50016-G5100-B333-04-7619

BS-4x / 82 II / 240 / 241 / 240XL commands

LAPDLE

name = LAPDLE:2
ChangeInfo = created
END OF OUTPUT FOR JOB 150
JOB: 151
PC Time&Date: 12:02:31 03/23/2005
NE Time&Date: 13:04:06 09/15/2004
USER NAME:

user_val1

COMMAND:
SSL0_16KB;

Create LAPDLE:NAME=LAPDLE:2,LAPDCH=BPORT0-1-

SW RELEASE:

01-04-17-01-26-51_05-02-23

COMMAND RESULT: Operation successful


END OF OUTPUT FOR JOB 151
Operation Failed
The specified Object has not been created. In addition to the general NACK causes, a
specific NACK cause, which indicates that the command is inconsistent with the
physical configuration, is possible. An example is the following:
JOB: 152
PC Time&Date: 12:02:31 03/23/2005
NE Time&Date: 13:04:06 09/15/2004
USER NAME:

user_val1

COMMAND:
SSL0_16KB;

Create LAPDLE:NAME=LAPDLE:1,LAPDCH=BPORT0-1-

SW RELEASE:

01-04-17-01-26-51_05-02-23

COMMAND RESULT: OPERATION FAILED


MO already created (-159)
END OF OUTPUT FOR JOB 152
Application Guidelines:

The LAPDLE object must be always created before the corresponding LPDLM
object on the BSC side, otherwise the Abis Alignment is going to fail

A50016-G5100-B333-04-7619

Id:0900d8058059599e

505

LAPDLE

BS-4x / 82 II / 240 / 241 / 240XL commands

Example of Command Execution:


Create LAPDLE:NAME=LAPDLE:0,LAPDCH=2-2-FULL_64KB;

DELETE LAPDLE
DELETE LAPDLE

NAME=LAPDLE:0..10;

Command Tree:
MANAGED-ELEMENT h BSS-EQUIPMENT h BTSEP h LAPDLE h DELETE
LAPDLE
Applicability:
Phase 2 and Phase 3.
Visibility level: 2.
Command Description:
This command deletes the LAPDLE from the BTSE data base.
Long Names:
NAME

Address of the managed object

System Responses:
Operation Completed
After command execution, a message of Changed Configuration Notification is displayed. A further message indicates the result of the operation. An example of delete
command is the following:
JOB: 158
PC Time&Date: 12:03:55 03/23/2005
NE Time&Date: 13:05:22 09/15/2004
USER NAME:

user_val1

SW RELEASE:

01-04-17-01-26-51_05-02-23

COMMAND RESULT: Operation successful


ChangedConfigurationNotification:
name = NAME=LAPDLE:2;
ChangeInfo = deleted
END OF OUTPUT FOR JOB 158
JOB: 159

506

Id:0900d8058059599e

A50016-G5100-B333-04-7619

BS-4x / 82 II / 240 / 241 / 240XL commands

LAPDLE

PC Time&Date: 12:04:03 03/23/2005


NE Time&Date: 13:05:35 09/15/2004
USER NAME:

user_val1

COMMAND:

Delete LAPDLE:NAME=LAPDLE:2;

SW RELEASE:

01-04-17-01-26-51_05-02-23

COMMAND RESULT: Operation successful


END OF OUTPUT FOR JOB 159
Operation Failed
The specified Object has not been deleted. Additionally to the general NACK causes, a
specific NACK cause, meaning that the command is inconsistent with physical configuration, is possible.
Application Guidelines:
None.
Example of Command Execution:
Delete LAPDLE:NAME=LAPDLE:0;

GET LAPDLE
GET LAPDLE

NAME=LAPDLE:0..10 [,REQATTL=ALS, AST, AVS,


LAPDCH, OST, PRS, RELFUNCOBJ, STDBYST];

Command Tree:
MANAGED-ELEMENT h BSS-EQUIPMENT h BTSEP h LAPDLE h GET
LAPDLE
Applicability:
Phase 2 and Phase 3.
Visibility level: 0.
Command Description:
This command displays the attributes of the LAPDLE unit of the BTSE.
Long Names:
NAME

Address of the managed object

REQATTL

Required attribute list

ALS

alarmStatus

AST

administrativeState

AVS

availabilityStatus

LAPDCH

lapdChannel

OST

operationalState

A50016-G5100-B333-04-7619

Id:0900d8058059599e

507

LAPDLE

BS-4x / 82 II / 240 / 241 / 240XL commands

PRS

proceduralStatus

RELFUNCOBJ
STDBYST

relatedFuncObjects
standbyStatus

System Responses:
Operation Completed
A message indicates the result of the operation. An example of get command is the following:
JOB: 149
PC Time&Date: 12:02:04 03/23/2005
NE Time&Date: 13:03:39 09/15/2004
USER NAME:

user_val1

COMMAND:

Get LAPDLE:NAME=LAPDLE:0;

SW RELEASE:

01-04-17-01-26-51_05-02-23

COMMAND RESULT: Operation successful


alarmStatus = CLEARED
administrativeState = Unlocked
availabilityStatus = NULL
lapdChannel =
BPORT = BPORT0
TSL = 17
SSL = FULL_64KB
operationalState = ENABLED
proceduralStatus = NULL
relatedFuncObjects =
standbyStatus = ColdStandBy
END OF OUTPUT FOR JOB 149
Operation Failed
The GET command has not been successfully executed. A general NACK will indicate
possible errors or a specific NACK strictly related to the single command is possible.
Application Guidelines:

The value for the attribute relatedFuncObjects in LMT Phase 2 is "not configured"

Example of Command Execution:


Get LAPDLE:NAME=RACK:0,REQATTL=ALS&AST&AVS&LAPCH&
RELFUNCOBJ&OST&PRS&STBYST;

508

Id:0900d8058059599e

A50016-G5100-B333-04-7619

BS-4x / 82 II / 240 / 241 / 240XL commands

RACK

RACK
The BS240/1 consists of a base rack with up to 8 TRXs. Optionally it can be connected
to two extension racks to reach up to 24 TRX. The BS240XL consists of a base rack with
up to 12 TRXs. Optionally it can be connected to an extension rack to reach up to 24
TRXs.

CREATE RACK
CREATE RACK

NAME=RACK:0..7 ,TYPRACK=;

Command Tree:
MANAGED-ELEMENT h BSS-EQUIPMENT h BTSEP h RACK h CREATE
RACK
Applicability:
Phase 2 and Phase 3.
Visibility level: 2.
Command Description:
This command adds the object RACK together with its attributes to the BTSE data base.
Long Names:
NAME

Address of the managed object

TYPRACK

typeOfBtse

System Responses:
Operation Completed
After command execution, a message of Changed Configuration Notification is displayed.
A further messagee indicates the result of the operation. An example of create
command is the following:

JOB: 230
PC Time&Date: 14:50:07 03/23/2005
NE Time&Date: 00:17:45 09/15/2004
USER NAME:

user_ NSN

SW RELEASE:

01-04-17-01-26-51_05-02-23

COMMAND RESULT: Operation successful


ChangedConfigurationNotification:

A50016-G5100-B333-04-7619

Id:0900d805805959a0

509

RACK

BS-4x / 82 II / 240 / 241 / 240XL commands

name = RACK:1
ChangeInfo = created
END OF OUTPUT FOR JOB 230
JOB: 231
PC Time&Date: 14:50:08 03/23/2005
NE Time&Date: 00:17:46 09/15/2004
USER NAME:

user_ NSN

COMMAND:

Create RACK:NAME=RACK:1;

SW RELEASE:

01-04-17-01-26-51_05-02-23

COMMAND RESULT Operation successful


END OF OUTPUT FOR JOB 231
Operation Failed
The specified Object has not been created. In addition to the general NACK causes, a
specific NACK cause, which indicates that the command is inconsistent with the
physical configuration, is possible. An example is the following:
JOB: 232
PC Time&Date: 14:50:08 03/23/2005
NE Time&Date: 00:17:46 09/15/2004
USER NAME:

user_ NSN

COMMAND:

Create RACK:NAME=RACK:1;

SW RELEASE:

01-04-17-01-26-51_05-02-23

COMMAND RESULT: OPERATION FAILED


MO already created (-159)
END OF OUTPUT FOR JOB 232
Application Guidelines:

510

RACK:0 can never be created. It had to be set, with Set RACK as first command

If an other rack type for RACK:0 is create, you had to format the flash and had to
make a power on; e.g. if you have at coba in DB (rack0) racktype BS242 (pico) and
want a racktype 240XL at coba. You had to format the flash and had to make a

Id:0900d805805959a0

A50016-G5100-B333-04-7619

BS-4x / 82 II / 240 / 241 / 240XL commands

RACK

power on at coba. With set rack or delete db this is not possible. (here you have different SW)

g The Create RACK command is no longer supported for BS240SWB, BS241SWB


and BS240XLSWB
Example of Command Execution:
Create RACK:NAME=RACK:1,TYPRACK=BS240;

DELETE RACK
DELETE RACK

NAME=RACK:0..7;

Command Tree:
MANAGED-ELEMENT h BSS-EQUIPMENT h BTSEP h RACK h DELETE
RACK
Applicability:
Phase 2 and Phase 3.
Visibility level: 2.
Command Description:
This command deletes the object RACK together with its attributes from the BTSE data
base.
Long Names:
NAME

Address of the managed object

System Responses:
Operation Completed
After command execution, a message of Changed Configuration Notification is displayed. A further message indicates the result of the operation. An example of delete
command is the following:
JOB: 233
PC Time&Date: 14:50:08 03/23/2005
NE Time&Date: 00:17:46 09/15/2004
USER NAME:

user_ NSN

SW RELEASE:

01-04-17-01-26-51_05-02-23

COMMAND RESULT: Operation successful


ChangedConfigurationNotification:
name = RACK:1

A50016-G5100-B333-04-7619

Id:0900d805805959a0

511

RACK

BS-4x / 82 II / 240 / 241 / 240XL commands

ChangeInfo = deleted
END OF OUTPUT FOR JOB 233
JOB: 234
PC Time&Date: 14:50:08 03/23/2005
NE Time&Date: 00:17:46 09/15/2004
USER NAME:

user_ NSN

COMMAND:

Delete RACK:NAME=RACK:1;

SW RELEASE:

01-04-17-01-26-51_05-02-23

COMMAND RESULT: Operation successful


END OF OUTPUT FOR JOB 234
Operation Failed
The specified Object has not been deleted. Additionally to the general NACK causes, a
specific NACK cause, meaning that the command is inconsistent with physical configuration, is possible.
Application Guidelines:

RACK:0 can never be deleted by DELETE command only using FORMAT FLASH
and power on

Example of Command Execution:


Delete RACK:NAME=RACK:1
The object can be deleted with format flash and power on.

GET RACK
GET RACK

NAME=RACK:0..7 [,REQATTL=ALS, AST, AVS, OST, PRS,


RELFUNCOBJ, TYPRACK];

Command Tree:
MANAGED-ELEMENT h BSS-EQUIPMENT h BTSEP h RACK h GET RACK
Applicability:
Phase 2 and Phase 3.
Visibility level: 0.
Command Description:
This command displays the attributes related to the specified RACK.
Long Names:
NAME

512

Address of the managed object

Id:0900d805805959a0

A50016-G5100-B333-04-7619

BS-4x / 82 II / 240 / 241 / 240XL commands

RACK

REQATTL

Required attribute list

ALS

alarmStatus

AST

administrativeState

AVS

availabilityStatus

OST

operationalState

PRS

proceduralStatus

RELFUNCOBJ
TYPRACK

relatedFuncObjects
typeOfBtse

System Responses:
Operation Completed
A message indicates the result of the operation. An example of get command is the following:
JOB: 5
PC Time&Date: 12:03:10 03/23/2005
NE Time&Date: 12:01:00 09/15/2004
USER NAME:

user_ NSN

COMMAND:

Get RACK:NAME=RACK:0;

SW RELEASE:

01-04-17-01-26-51_05-02-23

COMMAND RESULT: Operation successful


alarmStatus = MINOR
administrativeState = Unlocked
availabilityStatus = NULL
operationalState = ENABLED
proceduralStatus = NULL
relatedFuncObjects =
typeOfBtse = BS240XL
END OF OUTPUT FOR JOB 5
Operation Failed
The GET command has not been successfully executed. A general NACK will indicate
possible errors or a specific NACK strictly related to the single command is possible.
Application Guidelines:
None.

A50016-G5100-B333-04-7619

Id:0900d805805959a0

513

RACK

BS-4x / 82 II / 240 / 241 / 240XL commands

Example of Command Execution:


Get RACK:NAME=RACK:0,REQATTL=ALS&AST&AVS&RELFUNCOBJ&OST&
PRS&TYPRACK;

LOCK RACK
LOCK RACK

NAME=RACK:0..7;

Command Tree:
MANAGED-ELEMENT h BSS-EQUIPMENT h BTSEP h RACK h LOCK RACK
Applicability:
Phase 2 and Phase 3.
Visibility level: 1.
Command Description:
This command changes the administrative state of the object RACK.
Long Names:
NAME

Address of the managed object

System Responses:
Operation Completed
The specified change of administrative state has been perfomed:
JOB: 235
PC Time&Date: 14:50:08 03/23/2005
NE Time&Date: 00:17:46 09/15/2004
USER NAME:

user_ NSN

COMMAND:

Lock RACK:NAME=RACK:1;

SW RELEASE:

01-04-17-01-26-51_05-02-23

COMMAND RESULT: Operation successful


administrativeState = Locked
END OF OUTPUT FOR JOB 235

CHANGED STATE EVENT REPORT:


This provides information about the administrative state, the operational state and the
availability status every time a state change occurs:

514

Id:0900d805805959a0

A50016-G5100-B333-04-7619

BS-4x / 82 II / 240 / 241 / 240XL commands

RACK

JOB: 236
PC Time&Date: 14:50:08 03/23/2005
NE Time&Date: 00:17:46 09/15/2004
USER NAME:

user_ NSN

SW RELEASE:

01-04-17-01-26-51_05-02-23

COMMAND RESULT: Operation successful


CHANGED STATE EVENT REPORT:
NAME = RACK:1
Administrative State = LOCKED
Notification Identifier = 147
END OF OUTPUT FOR JOB 236
Operation Failed
The specified change of administrative state has not been performed.
Application Guidelines:

RACK:0 can never be locked

Example of Command Execution:


Lock RACK:NAME=RACK:1;

SET RACK
SET RACK

NAME=RACK:0..7 [,TYPRACK=];

Command Tree:
MANAGED-ELEMENT h BSS-EQUIPMENT h BTSEP h RACK h SET RACK
Applicability:
Phase 2.
Visibility level: 2.
Command Description:
This command is used to set the attributes of the specified RACK.
Long Names:
NAME

Address of the managed object

TYPRACK

typeOfBtse

System Responses:
Operation Completed

A50016-G5100-B333-04-7619

Id:0900d805805959a0

515

RACK

BS-4x / 82 II / 240 / 241 / 240XL commands

After command execution, a message of Changed Attribute Event Report is displayed.


A further message indicates the result of the operation. An example of set command is
the following:
JOB: 176
PC Time&Date: 12:05:36 03/23/2005
NE Time&Date: 13:07:12 09/15/2004
USER NAME:

user_ NSN

COMMAND:

Set RACK:NAME=RACK:0;

SW RELEASE:

01-04-17-01-26-51_05-02-23

COMMAND RESULT: Operation successful


END OF OUTPUT FOR JOB 176
Operation Failed
The specified attributes have not been set. In addition to the general NACK causes, a
specific NACK cause, which indicates that the command is inconsistent with the
physical configuration, is possible.
Application Guidelines:

The attribute TYPRACK must be set. Otherwise the OMC is not able to identify the
BTSE

RACK:0 has to be set, otherwise no object can be created

RACK:0 cannot be changed, it has to be deleted by delete BTSEPDBFILE (e.g., if


you have a coba with rack BS240 and want a racktype 240XL you have to delete
dbfile (delete DB). Here you have the same SW)

g The Set RACK command is no longer supported for BS240SWB, BS241SWB and
BS240XLSWB
Example of Command Execution:
Set RACK:NAME=RACK:0,TYPRACK=BS240;

UNLOCK RACK
UNLOCK RACK

NAME=RACK:0..7;

Command Tree:
MANAGED-ELEMENT h BSS-EQUIPMENT h BTSEP h RACK h UNLOCK
RACK
Applicability:
Phase 2 and Phase 3.
Visibility level: 1.

516

Id:0900d805805959a0

A50016-G5100-B333-04-7619

BS-4x / 82 II / 240 / 241 / 240XL commands

RACK

Command Description:
This command changes the administrative state of the object RACK.
Long Names:
NAME

Address of the managed object

System Responses:
Operation Completed
The specified change of administrative state has been perfomed:
JOB: 237
PC Time&Date: 14:50:08 03/23/2005
NE Time&Date: 00:17:46 09/15/2004
USER NAME:

user_ NSN

COMMAND:

Unlock RACK:NAME=RACK:1;

SW RELEASE:

01-04-17-01-26-51_05-02-23

COMMAND RESULT: Operation successful


administrativeState = Unlocked
END OF OUTPUT FOR JOB 237

CHANGED STATE EVENT REPORT:


This provides information about the administrative state, the operational state and the
availability status every time a state change occurs:
JOB: 238
PC Time&Date: 14:50:09 03/23/2005
NE Time&Date: 00:17:47 09/15/2004
USER NAME:

user_ NSN

SW RELEASE:

01-04-17-01-26-51_05-02-23

COMMAND RESULT: Operation successful


CHANGED STATE EVENT REPORT:
NAME = RACK:1

A50016-G5100-B333-04-7619

Id:0900d805805959a0

517

RACK

BS-4x / 82 II / 240 / 241 / 240XL commands

Administrative State = UNLOCKED


Notification Identifier = 321
END OF OUTPUT FOR JOB 237
Operation Failed
The specified change of administrative state has not been performed.
Application Guidelines:
None.
Example of Command Execution:
Unlock RACK:NAME=RACK:0;

518

Id:0900d805805959a0

A50016-G5100-B333-04-7619

BS-4x / 82 II / 240 / 241 / 240XL commands

REMINV

REMINV
The REMINV (Remote Inventory) object manages the BTSE local Inventory Data Table
(IDT) in case of installation of new hardware objects or replacement of already existing
hardware objects.

DNLIDFD REMINV
DNLIDFD REMINV

NAME=REMINV:0..0 [,SRCDIR=];

Command Tree:
MANAGED-ELEMENT h BSS-EQUIPMENT h BTSEP h REMINV h DNLIDFD
REMINV
Applicability:
Phase 2 and Phase 3.
Visibility level: 1.
Command Description:
This command executes the download of the NOB file (containing nob_RIUs of the IDF)
from the LMT hard disk to the BTSE flash EPROMs.
Long Names:
NAME

Address of the managed object

SRCDIR

sourceDir

System Responses:
Operation Completed
After command execution, a further message indicates the result of the operation. An
example of dnlidfd command is the following:
JOB: 155
PC Time&Date: 12:03:15 03/23/2005
NE Time&date: 0:00:00 00/00/0
USER NAME:

user_ NSN

COMMAND:

Dnlidfd REMINV:NAME=REMINV:0,SRCDIR="C:\labuser\BsPlus";

SW RELEASE:

N.A.

COMMAND RESULT: Operation successful


END OF OUTPUT FOR JOB 155
Operation Failed
None.

A50016-G5100-B333-04-7619

Id:0900d805805959a2

519

REMINV

BS-4x / 82 II / 240 / 241 / 240XL commands

Application Guidelines:
This file is to be created previously using the "IDF-Editor". The name for BTSE is fix
"BTS_NRIU".
Example of Command Execution:
Dnlidfd REMINV:SRCDIR="C:\Programme\IdfEditor|\dnload";

UPLLIDF REMINV
UPLLIDF REMINV

NAME=REMINV:0..0 [,DESTDIR=] [,FILE=] ,OVERWRITE=;

Command Tree:
MANAGED-ELEMENT h BSS-EQUIPMENT h BTSEP h REMINV h UPLLIDF
REMINV
Applicability:
Phase 1 and Phase 2 and Phase 3.
Visibility level: 1.
Command Description:
This command executes the uploading of the IDF (Inventory Data File) from the BTSE
flash EPROMs to the LMT hard disk.
Long Names:
NAME

Address of the managed object

DESTDIR

destinationDir

FILE

file

OVERWRITE

Overwrite

System Responses:
Operation Completed
After command execution, a further message indicates the result of the operation. An
example of upllidf command is the following:
JOB: 156
PC Time&Date: 12:03:18 03/23/2005
NE Time&date: 0:00:00 00/00/0
USER NAME:

user_ NSN

COMMAND:

Upllidf REMINV:NAME=REMINV:0,OVERWRITE=YES;

SW RELEASE:

N.A.

COMMAND RESULT: Operation successful


Uploading File: BTSE.IDT

520

Id:0900d805805959a2

A50016-G5100-B333-04-7619

BS-4x / 82 II / 240 / 241 / 240XL commands

REMINV

To: BTSE.IDT
On Directory: ..\Idf\Upload
END OF OUTPUT FOR JOB 156
JOB: 157
PC Time&Date: 12:03:19 03/23/2005
NE Time&date: 00:00:00 00/00/0
USER NAME:

user_ NSN

COMMAND:

Upllidf REMINV:NAME=REMINV:0,OVERWRITE=YES;

SW RELEASE:

01-04-17-01-26-51_05-02-23

COMMAND RESULT: Operation successful


Upload End: File BTSE.IDT Transfer Completed
END OF OUTPUT FOR JOB 157
Operation Failed
None.
Application Guidelines:

The offline tool "IDF-Editor" is used to display and modify the uploaded IDT. It is
used also for converting the IDT into an IDF or to extract the NOB file

The default value of FILE is BTSE.IDT

Example of Command Execution:


Uplidfd REMINV:DESTDIR="c:\rem_inve",FILE="bts_inv.idt",OVERWRITE=YES;

A50016-G5100-B333-04-7619

Id:0900d805805959a2

521

SOFTWARE-MANAGEMENT

BS-4x / 82 II / 240 / 241 / 240XL commands

SOFTWARE-MANAGEMENT
The SOFTWARE-MANAGEMENT object provide the functionality to execute BSS software management and to administrate the BTSE file system.

DNLALLEXE SOFTWARE-MANAGEMENT
DNLALLEXE
SRCPATH= ,OVERWRITE=;
SOFTWARE-MANAGEMENT
Command Tree:
MANAGED-ELEMENT h SOFTWARE-MANAGEMENT h DNLALLEXE
SOFTWARE-MANAGEMENT
Applicability:
Phase 1 and Phase 2.
Visibility level: 0.
Command Description:
This command executes the software downloading of the BTS-SW from the LMT PC
hard disk to the COBA.
Long Names:
IDSOFTWARE-MANAGEMENT
SRCPATH

srcpath

OVERWRITE

Overwrite

Address of the managed object

System Responses:
Operation Completed
Download START. After command execution, a further message indicates the result of
the operation. An example of dnlallexe command is the following:
JOB: 175
PC Time&Date: 12:05:17 03/23/2005
NE Time&date: 0:00:00 00/00/0
USER NAME:

User_NSN

COMMAND:
DNLALLEXE:SRCPATH="<disk partition>:\<installation directory>\
hs031785\HS011722.SWL",OVERWRITE=YES;
SW RELEASE:

01-04-17-01-26-51_05-02-23

COMMAND RESULT: Operation successful


Downloading File: HS011726.SWL:01-04-17-01-26-51_05-02-23

522

Id:0900d805805959a4

A50016-G5100-B333-04-7619

BS-4x / 82 II / 240 / 241 / 240XL commands

SOFTWARE-MANAGEMENT

Version: 02-08-01-01-00-27_04-11-19
END OF OUTPUT FOR JOB 175
Operation Failed
= (invalid SW-Version, defective SW)
Application Guidelines:

If the incorrect SW version is given, the system will reject the command

The SWLoadSafety will not be overwritten

In Phase 1 this command is followed by a forced download

In Phase 2 the command is followed by a forced download if the SwVersion is identical to the currentSWLoad

Recent BTS SW productions expect 64M RAM, the SW doesn't work with old
CESCOBA

Example of Command Execution:


Dnlallexe:SRCPATH="c:\path\HS011722.SWL", OVERWRITE= YES;

UPLBTSLOG SOFTWARE-MANAGEMENT
UPLBTSLOG
FILETYPE= ,DESTDIR= ,FILE= [,ENTRIES=] ,OVERSOFTWARE-MANAGE- WRITE=;
MENT
Command Tree:
MANAGED-ELEMENT h SOFTWARE-MANAGEMENT h UPLBTSLOG
SOFTWARE-MANAGEMENT
Applicability:
Phase 2 and Phase 3.
Visibility level: 2.
Command Description:
The uUser_NSNe of this command is reserved to the R&D and should be used only
under R&D request.
Long Names:
IDSOFTWARE-MANAGEMENT
FILETYPE

FileType

DESTDIR

destinationDir

FILE

file

ENTRIES

entries

OVERWRITE

Overwrite

Address of the managed object

System Responses:
Operation Completed

A50016-G5100-B333-04-7619

Id:0900d805805959a4

523

SOFTWARE-MANAGEMENT

BS-4x / 82 II / 240 / 241 / 240XL commands

After command execution, a further message indicates the result of the operation. An
example of uplbtslog command is the following:
JOB: 177
PC Time&Date: 12:06:04 03/23/2005
NE Time&date: 0:00:00 00/00/0
USER NAME:

User_NSN

COMMAND:
WRITE=YES;

UPLBTSLOG:DESTDIR="D:\DocumentBtsplus",FILE="240xl",OVER-

SW RELEASE:

N.A.

COMMAND RESULT: Operation successful


Uploading File: 240xl
To: 240xl
On Directory: D:\DocumentBtsplus
END OF OUTPUT FOR JOB 177
JOB: 178
PC Time&Date: 12:06:25 03/23/2005
NE Time&date: 00:00:00 00/00/0
USER NAME:

User_NSN

COMMAND:
WRITE=YES;

UPLBTSLOG:DESTDIR="D:\DocumentBtsplus",FILE="240xl",OVER-

SW RELEASE:

01-04-17-01-26-51_05-02-23

COMMAND RESULT: Operation successful


Uploading File 240xl:
100 packets received
END OF OUTPUT FOR JOB 178
Operation Failed
None.
Application Guidelines:
None.

524

Id:0900d805805959a4

A50016-G5100-B333-04-7619

BS-4x / 82 II / 240 / 241 / 240XL commands

SOFTWARE-MANAGEMENT

Example of Command Execution:


The execution of this command is reserved to the R&D and should be executed only
under R&D request.

A50016-G5100-B333-04-7619

Id:0900d805805959a4

525

SYNCBTSE

BS-4x / 82 II / 240 / 241 / 240XL commands

SYNCBTSE
The SYNCBTSE object which holds operator configurable parameters and indicates the
synchronization state and accuracy. This is sufficient to maintain configuration and
states, so no further modeling of the external GPS equipment is necessary.

GET SYNCBTSE
GET SYNCBTSE

NAME=SYNCBTSE:0..0 [,REQATTL=ALS, AST, AVS,


CLKACC, MPHERR, MRSYNCT, OST, PRS, RELFUNCOBJ, SBPRT, SYNCSRC, SYNCSTAT];

Command Tree:
MANAGED-ELEMENT h BSS-EQUIPMENT h BTSEP h SYNCBTSE h GET
SYNCBTSE
Applicability:
Phase 2 and Phase 3.
Visibility level: 0.
Command Description:
This command displays the attributes of the SYNCBTSE of the BTSE.
Long Names:
NAME

Address of the managed object

REQATTL

Required attribute list

ALS

alarmStatus

AST

administrativeState

AVS

availabilityStatus

CLKACC

clockAccuracy

MPHERR

maxPhaseError(microsec)

MRSYNCT

maxResyncTime(min)

OST

operationalState

PRS

proceduralStatus

RELFUNCOBJ

relatedFuncObjects

SBPRT

syncBport

SYNCSRC

syncSource

SYNCSTAT

syncState

System Responses:
Operation Completed
A message indicates the result of the operation. An example of get command is the following:
JOB: 7

526

Id:0900d805805959a6

A50016-G5100-B333-04-7619

BS-4x / 82 II / 240 / 241 / 240XL commands

SYNCBTSE

PC Time&Date: 16:24:35 03/23/2005


NE Time&Date: 16:22:29 09/15/2004
USER NAME:

User_NSN

COMMAND:

Get SYNCBTSE:NAME=SYNCBTSE:0;

SW RELEASE:

01-04-17-01-26-51_05-02-23

COMMAND RESULT: Operation successful


alarmStatus = CLEARED
administrativeState = Unlocked
availabilityStatus = NULL
clockAccuracy = high
maxPhaseError(microsec) = 1.5
maxResyncTime(min) = 180
operationalState = ENABLED
proceduralStatus = NULL
relatedFuncObjects =
syncSource = abis
syncState = abis
END OF OUTPUT FOR JOB 7
Operation Failed
The GET command has not been successfully executed. A general NACK will indicate
possible errors or a specific NACK strictly related to the single command is possible.
Application Guidelines:
None.
Example of Command Execution:
Get SYNCBTSE:NAME=SYNCBTSE:0,REQATTL=ALS&AST&AVS&BCPBL&
CLKACC&MPHERR&MRSYNCT&OST&PRS&RELFUNCOBJ&SYNCSRC&
SYNCSTAT;

GETTEST SYNCBTSE
GETTEST SYNCBTSE

NAME=SYNCBTSE:0..0;

Command Tree:
MANAGED-ELEMENT h BSS-EQUIPMENT h BTSEP h SYNCBTSE h
GETTEST SYNCBTSE

A50016-G5100-B333-04-7619

Id:0900d805805959a6

527

SYNCBTSE

BS-4x / 82 II / 240 / 241 / 240XL commands

Applicability:
Phase 2 and Phase 3.
Visibility level: 0.
Command Description:
This command displays the attributes of the SYNCBTSE test.
Long Names:
NAME

Address of the managed object

REQATTL

Required attribute list

System Responses:
Operation Completed
A message indicates the result of the operation. An example of gettest command is the
following:
JOB: 300
PC Time&Date: 14:50:17 03/23/2005
NE Time&Date: 00:17:55 09/15/2004
USER NAME:

User_NSN

COMMAND:

Gettest SYNCBTSE:NAME=SYNCBTSE:0;

SW RELEASE:

01-04-17-01-26-51_05-02-23

COMMAND RESULT: Operation successful


MOT = SYNCBTSE:0
testMonitor =
phaseId = PreliminaryTestsSYNCBTSE
phaseStatus = Running
phaseId = CheckAlarmStatusSYNCBTSE
phaseStatus = Waiting
phaseId = EndTestSYNCBTSE
phaseStatus = Waiting
testOutcome = INCONCLUSIVE
testState = INITIALIZING
END OF OUTPUT FOR JOB 300
Operation Failed
The GET command has not been successfully executed. A general NACK will indicate
possible errors or a specific NACK strictly related to the single command is possible.

528

Id:0900d805805959a6

A50016-G5100-B333-04-7619

BS-4x / 82 II / 240 / 241 / 240XL commands

testMonitor
phaseId =
phaseStatus =

SYNCBTSE

it is a list of all test phases related to the


selected object; for each phase the
related phaseStatus is provided (Passed,
Failed, Running or Waiting).

phaseId =
phaseStatus =
...
...
testOutcome

It represents the test result: it can be


Inconclusive (if the phases already
executed were successful) or Fail (if at
least one of the executed phases failed).

testState = Testing

It can assume one of the following values:


not_initialized, idle, initializing, suspended, testing, terminating and disabled.

Application Guidelines:
None.
Example of Command Execution:
Gettest SYNCBTSE:NAME=SYNCBTSE:0,REQATTL=MORT&TESTMON&
TESTOUT&TESTST;

LOCK SYNCBTSE
LOCK SYNCBTSE

NAME=SYNCBTSE:0..0;

Command Tree:
MANAGED-ELEMENT h BSS-EQUIPMENT h BTSEP h SYNCBTSE h LOCK
SYNCBTSE
Applicability:
Phase 2 and Phase 3.
Visibility level: 1.
Command Description:
This command changes the administrative state of the SYNCBTSE of the BTSE.
Long Names:
NAME

Address of the managed object

System Responses:
Operation Completed
The specified change of administrative state has been perfomed:

A50016-G5100-B333-04-7619

Id:0900d805805959a6

529

SYNCBTSE

BS-4x / 82 II / 240 / 241 / 240XL commands

JOB: 8
PC Time&Date: 16:24:42 03/23/2005
NE Time&Date: 16:22:36 09/15/2004
USER NAME:

User_NSN

COMMAND:

Lock SYNCBTSE:NAME=SYNCBTSE:0;

SW RELEASE:

01-04-17-01-26-51_05-02-23

COMMAND RESULT: Operation successful


administrativeState = Locked
END OF OUTPUT FOR JOB 8

CHANGED STATE EVENT REPORT:


This provides information about the administrative state, the operational state and the
availability status every time a state change occurs:
JOB: 9
PC Time&Date: 16:24:42 03/23/2005
NE Time&Date: 16:22:36 09/15/2004
USER NAME:

User_NSN

SW RELEASE:

01-04-17-01-26-51_05-02-23

COMMAND RESULT: Operation successful


CHANGED STATE EVENT REPORT:
NAME = SYNCBTSE:0
Administrative State = LOCKED
Notification Identifier = 461
END OF OUTPUT FOR JOB 9
Operation Failed
The specified change of administrative state has not been performed (e.g. the object is
redundant and its spare copy is disabled or already locked, a subordinate resource
cannot go into disabled state with "dependency" availability status).

530

Id:0900d805805959a6

A50016-G5100-B333-04-7619

BS-4x / 82 II / 240 / 241 / 240XL commands

SYNCBTSE

Application Guidelines:
Lock of SYNCBTSE (= SET administrativeState to locked) is rejected if syncSource =
ext_1pps_only.
Example of Command Execution:
Lock SYNCBTSE:NAME=SYNCBTSE:0;

PERFTEST SYNCBTSE
PERFTEST SYNCBTSE NAME=SYNCBTSE:0..0;
Command Tree:
MANAGED-ELEMENT h BSS-EQUIPMENT h BTSEP h SYNCBTSE h
PERFTEST SYNCBTSE
Applicability:
Phase 2 and Phase 3.
Visibility level: 1.
Command Description:
This command is used to start an asynchronous test in SYNCBTSE.
Long Names:
NAME

Address of the managed object

System Responses:
Operation Completed
Test configuration has been set and the specified test has been started. The System
response will not be addressed to the MOT but to the object BTSE.
JOB: 240
PC Time&Date: 14:50:09 03/23/2005
NE Time&Date: 00:17:47 09/15/2004
USER NAME:

User_NSN

COMMAND:

Perftest SYNCBTSE:NAME=SYNCBTSE:0;

SW RELEASE:

01-04-17-01-26-51_05-02-23

COMMAND RESULT: Operation successful


MOT = SYNCBTSE
tO = BTSETEST:1
END OF OUTPUT FOR JOB 240

A50016-G5100-B333-04-7619

Id:0900d805805959a6

531

SYNCBTSE

BS-4x / 82 II / 240 / 241 / 240XL commands

JOB: 241
PC Time&Date: 14:50:09 03/23/2005
NE Time&Date: 00:17:47 09/15/2004
USER NAME:

User_NSN

SW RELEASE:

01-04-17-01-26-51_05-02-23

COMMAND RESULT: Operation successful


ChangedConfigurationNotification:
name = BTSETEST:1
ChangeInfo = created
END OF OUTPUT FOR JOB 241
JOB: 242
PC Time&Date: 14:50:12 03/23/2005
NE Time&Date: 00:17:51 09/15/2004
USER NAME:

User_NSN

SW RELEASE:

01-04-17-01-26-51_05-02-23

COMMAND RESULT: Operation successful


CHANGED STATE EVENT REPORT:
NAME = SYNCBTSE:0
Operational State = ENABLED
Availability Status = NULL_value
Notification Identifier = 143
END OF OUTPUT FOR JOB 242
JOB: 243
PC Time&Date: 14:50:12 03/23/2005
NE Time&Date: 00:17:51 09/15/2004
USER NAME:

532

User_NSN

Id:0900d805805959a6

A50016-G5100-B333-04-7619

BS-4x / 82 II / 240 / 241 / 240XL commands

SW RELEASE:

SYNCBTSE

01-04-17-01-26-51_05-02-23

COMMAND RESULT: Operation successful


Test Report:
name = BTSETEST:1
testOutcome = PASSED
testTermination = Normal
MOT = SYNCBTSE:0
executedPhases =
PreliminaryTestsSYNCBTSE
CheckAlarmStatusSYNCBTSE
EndTestSYNCBTSE
END OF OUTPUT FOR JOB 243
JOB: 244
PC Time&Date: 14:50:09 03/23/2005
NE Time&Date: 00:17:47 09/15/2004
USER NAME:

User_NSN

SW RELEASE:

01-04-17-01-26-51_05-02-23

COMMAND RESULT: Operation successful


ChangedConfigurationNotification:
name = BTSETEST:1
ChangeInfo = deleted
END OF OUTPUT FOR JOB 244
The test results will be displayed at the end of the test phases.
Result TEST:
name =

TEST:<n>

testOutcome =

This field represents the test result; one of the following values can be displayed:
Pass

A50016-G5100-B333-04-7619

Id:0900d805805959a6

all the test phases are successfully


performed.

533

SYNCBTSE

BS-4x / 82 II / 240 / 241 / 240XL commands

Inconclusive

the test is aborted by the system or


the test is terminated by the operator.

Fail

if at least one of the executed phases


fail.

mOts =

It is the identifier of the hardware object under test.

testTermination =

It specifies how the test is terminated, it can assume


the following values:
Normal

all the test phases are performed.

Abort

the test is aborted by system.

Cancel

the test is terminated by operator.

executedPhases
phaseId =
additionalWords =
....

It represents the list of the executed test phases (in


case of successful test result, all the test phases will
be listed).

failedPhases
phaseId =

It represents the list of the failed test phase; additional information is provided for each phase.

phaseId =
....
skippedPhases
phaseId =

It represents the list of the skipped phases; they are


displayed only for test stopped during it execution.

phaseId =
....
poprosedRepair Action
=

A list of most probable fail probable causes is shown


(max four messages)

Operation Failed
This NACK-message occurs in the following cases: Message cannot be performed, test
not supported, capacity restrictions, physical configuration cannot be performed, object
not locked.
Application Guidelines:
None.
Example of Command Execution:
Perftest SYNCBTSE:NAME=SYNCBTSE:0;

SET SYNCBTSE
SET SYNCBTSE

534

NAME=SYNCBTSE:0..0 [,MPHERR=] [,MRSYNCT=]


[,SYNCSRC=];

Id:0900d805805959a6

A50016-G5100-B333-04-7619

BS-4x / 82 II / 240 / 241 / 240XL commands

SYNCBTSE

Command Tree:
MANAGED-ELEMENT h BSS-EQUIPMENT h BTSEP h SYNCBTSE h SET
SYNCBTSE
Applicability:
Phase 2 and Phase 3.
Visibility level: 2.
Command Description:
This command sets the attributes for the mapping of the SYNCBTSE.
Long Names:
NAME

Address of the managed object

MPHERR

maxPhaseError(microsec)

MRSYNCT

maxResyncTime(min)

SYNCSRC

syncSource

System Responses:
Operation Completed
The specified attribute has been set. In addition, a Changed Attribute Event Report indicates that the command has been successfully executed:
JOB: 20
PC Time&Date: 12:06:33 03/23/2005
NE Time&Date: 12:04:23 09/15/2004
USER NAME:

User_NSN

COMMAND:
SRC=abis;

Set SYNCBTSE:NAME=SYNCBTSE:0,MPHERR=1.5,SYNC-

SW RELEASE:

01-04-17-01-26-51_05-02-23

COMMAND RESULT: Operation successful


maxPhaseError(microsec) = 1.5
syncSource = abis
END OF OUTPUT FOR JOB 20
Operation Failed
The specified Object has not been created. In addition to the general NACK causes, a
specific NACK cause, which indicates that the command is inconsistent with the
physical configuration, is possible.

A50016-G5100-B333-04-7619

Id:0900d805805959a6

535

SYNCBTSE

BS-4x / 82 II / 240 / 241 / 240XL commands

Application Guidelines:
Setting syncSource to "ext_1pps_only" is rejected for COBA different than COBA4P12
version 2 or CESCOBA.
Setting syncSource to "ext_1pps_only" is rejected if administrativeState of SYNCBTSE
is locked.
Example of Command Execution:
Set SYNCBTSE:NAME=SYNCBTSE:0,MPHERR=1.5,MRSYNCT=200,
SYNCSRC=extGPS;

STOPTEST SYNCBTSE
STOPTEST SYNCBTSE NAME=SYNCBTSE:0..0;
Command Tree:
MANAGED-ELEMENT h BSS-EQUIPMENT h BTSEP h SYNCBTSE h
STOPTEST SYNCBTSE
Applicability:
Phase 2 and Phase 3.
Visibility level: 1.
Command Description:
This command is used to stop a diagnostic previously started.
Long Names:
NAME

Address of the managed object

System Responses:
Operation Completed
Test has been stopped. The System Responses will not be addressed to the MOT but
to the object BTSEP.

Result TEST:
name =

TEST:<n>

testOutcome =

inconclusive

mOts =

It is the identifier of the hardware object under test.

testTermination =

Cancel

executedPhases
phaseId =
...
.

It represents the list of the executed test phases; the


list is not shown for test in the waiting list (queued).

failedPhases

536

Id:0900d805805959a6

A50016-G5100-B333-04-7619

BS-4x / 82 II / 240 / 241 / 240XL commands

SYNCBTSE

phaseId =

It represents the list of the failed test phase;

phaseId =

additional information is provided for each phase.

....
skippedPhases
phaseId =

It represents the list of the skipped phases;the list is


not shown for test in the waiting list (queued).

phaseId =
Operation Failed

Test has not been stopped. This NACK-message can occur when the specified test is
not running or in case of test which cannot be stopped.
Application Guidelines:
None.
Example of Command Execution:
Stoptest SYNCBTSE:NAME=SYNCBTSE:0;

UNLOCK SYNCBTSE
UNLOCK SYNCBTSE

NAME=SYNCBTSE:0..0;

Command Tree:
MANAGED-ELEMENT h BSS-EQUIPMENT h BTSEP h SYNCBTSE h
UNLOCK SYNCBTSE
Applicability:
Phase 2 and Phase 3.
Visibility level: 1.
Command Description:
This command changes the administrative state of the SYNCBTSE to the BTSE.
Long Names:
NAME

Address of the managed object

System Responses:
Operation Completed
The specified change of administrative state has been perfomed:
JOB: 10
PC Time&Date: 16:24:48 03/23/2005
NE Time&Date: 16:22:42 09/15/2004
USER NAME:

A50016-G5100-B333-04-7619

User_NSN

Id:0900d805805959a6

537

SYNCBTSE

BS-4x / 82 II / 240 / 241 / 240XL commands

COMMAND:

Unlock SYNCBTSE:NAME=SYNCBTSE:0;

SW RELEASE:

01-04-17-01-26-51_05-02-23

COMMAND RESULT: Operation successful


administrativeState = Unlocked
END OF OUTPUT FOR JOB 10

CHANGED STATE EVENT REPORT:


This provides information about the administrative state, the operational state and the
availability status every time a state change occurs:
JOB: 11
PC Time&Date: 16:24:48 03/23/2005
NE Time&Date: 16:22:42 09/15/2004
USER NAME:

User_NSN

SW RELEASE:

01-04-17-01-26-51_05-02-23

COMMAND RESULT: Operation successful


CHANGED STATE EVENT REPORT:
NAME = SYNCBTSE:0
Administrative State = UNLOCKED
Notification Identifier = 462
END OF OUTPUT FOR JOB 11
Operation Failed
The specified change of administrative state has not been performed.
Application Guidelines:
None.
Example of Command Execution:
Unlock SYNCBTSE:NAME=SYNCBTSE:0;

538

Id:0900d805805959a6

A50016-G5100-B333-04-7619

BS-4x / 82 II / 240 / 241 / 240XL commands

TMA

TMA
The TMA object represents the tower mounted amplifier.

CREATE TMA
CREATE TMA

NAME=RACK:0..7/TMA:0..15;

Command Tree:
MANAGED-ELEMENT h BSS-EQUIPMENT h BTSEP h RACK h TMA h
CREATE TMA
Applicability:
Phase 2 and Phase 3.
Visibility level: 2.
Command Description:
This command adds the TMA (Tower Mounted Amplifier) to the BTSE data base.
Long Names:
NAME

Address of the managed object

System Responses:
Operation Completed
After command execution, a message of Changed Configuration Notification is displayed.
A further message indicates the result of the operation. An example of create command
is the following:
JOB: 5
PC Time&Date: 16:24:23 03/23/2005
NE Time&Date: 16:22:17 09/15/2004
USER NAME:

User_Chris

SW RELEASE:

01-04-17-01-26-51_05-02-23

COMMAND RESULT: Operation successful


ChangedConfigurationNotification:
name = RACK:0/TMA:0
ChangeInfo = created
END OF OUTPUT FOR JOB 5

A50016-G5100-B333-04-7619

Id:0900d805805959a8

539

TMA

BS-4x / 82 II / 240 / 241 / 240XL commands

JOB: 6
PC Time&Date: 16:24:23 03/23/2005
NE Time&Date: 16:22:17 09/15/2004
USER NAME:

User_Chris

COMMAND:

Create TMA:NAME=RACK:0/TMA:0;

SW RELEASE:

01-04-17-01-26-51_05-02-23

COMMAND RESULT: Operation successful


END OF OUTPUT FOR JOB 6
Operation Failed
The specified Object has not been created. In addition to the general NACK causes, a
specific NACK cause, which indicates that the command is inconsistent with the
physical configuration, is possible. An example is the following:
JOB: 80
PC Time&Date: 16:37:54 03/23/2005
NE Time&Date: 16:35:47 09/15/2004
USER NAME:

User_Chris

COMMAND:

Create TMA:NAME=RACK:0/TMA:0;

SW RELEASE:

01-04-17-01-26-51_05-02-23

COMMAND RESULT: OPERATION FAILED


Object instance unknown (-9)
END OF OUTPUT FOR JOB 80
Application Guidelines:

The DUAMCO/DIAMCO amplifier has two different operation modes which can be
selected by e.g. DIP switches. In case a TMA is used the DUAMCO/DIAMCO must
be configured in the MUCO mode. If no TMA is used the DUAMCO/DIAMCO must
be configured in the AMCO mode

As in the MUCO mode the gain is reduced to about 0 dB, the exact gain of the
DUAMCO/DIAMCO to compensate the cable losses must be adjusted once during
the installation of the BTSE by the service personnel

Example of Command Execution:


Create TMA:NAME=RACK:0/TMA:0;

540

Id:0900d805805959a8

A50016-G5100-B333-04-7619

BS-4x / 82 II / 240 / 241 / 240XL commands

TMA

DELETE TMA
DELETE TMA

NAME=RACK:0..7/TMA:0..15;

Command Tree:
MANAGED-ELEMENT h BSS-EQUIPMENT h BTSEP h RACK h TMA h
DELETE TMA
Applicability:
Phase 2 and Phase 3.
Visibility level: 2.
Command Description:
This command deletes the TMA (Tower Mounted Amplifier) to the BTSE data base.
Long Names:
NAME

Address of the managed object

System Responses:
Operation Completed
After command execution, a message of Changed Configuration Notification is displayed. A further message indicates the result of the operation. An example of delete
command is the following:
JOB: 14
PC Time&Date: 16:24:59 03/23/2005
NE Time&Date: 16:22:53 09/15/2004
USER NAME:

User_Chris

SW RELEASE:

01-04-17-01-26-51_05-02-23

COMMAND RESULT: Operation successful


ChangedConfigurationNotification:
name = RACK:0/TMA:0
ChangeInfo = deleted
END OF OUTPUT FOR JOB 14
JOB: 15
PC Time&Date: 16:24:59 03/23/2005
NE Time&Date: 16:22:53 09/15/2004

A50016-G5100-B333-04-7619

Id:0900d805805959a8

541

TMA

BS-4x / 82 II / 240 / 241 / 240XL commands

USER NAME:

User_Chris

COMMAND:

Delete TMA:NAME=RACK:0/TMA:0;

SW RELEASE:

01-04-17-01-26-51_05-02-23

COMMAND RESULT: Operation successful


END OF OUTPUT FOR JOB 15
Operation Failed
The specified Object has not been deleted. Additionally to the general NACK causes, a
specific NACK cause, meaning that the command is inconsistent with physical configuration, is possible.
Application Guidelines:

TMA must be locked in phase 3 before deletion

If a DULNA or DILNA with attribute "InaPredecessor" containing a TMA should be


deleted, then the tMA contained the attribute has to be deleted before

Example of Command Execution:


Delete TMA:NAME=RACK:0/TMA:0;

GET TMA
GET TMA

NAME=RACK:0..7/TMA:0..15 [,REQATTL=ALS, AST, AVS,


OST, PRS, RELFUNCOBJ, PRDINF, ANTMN, ANTSN,
BND<x>, BMWD<x>, GN<x>, SUBUNT, RXBMINF,
RXBMAXF, TXBMINF, TXBMAXF, MAXGN, MINGN, GNR,
INSD, INSID, BTSID, SCID, ANTB, MTLT];

Command Tree:
MANAGED-ELEMENT h BSS-EQUIPMENT h BTSEP h RACK h TMA h GET
TMA
Applicability:
Phase 2 and Phase 3.
Visibility level: 0.
Command Description:
This command displays the attributes of TMA.
Long Names:

542

NAME

Address of the managed object

REQATTL

Required attribute list

ALS

alarmStatus

AST

administrativeState

AVS

availabilityStatus

OST

operationalState

Id:0900d805805959a8

A50016-G5100-B333-04-7619

BS-4x / 82 II / 240 / 241 / 240XL commands

PRS

TMA

proceduralStatus

RELFUNCOBJ

relatedFuncObjects

PRDINF

productInfo(prodNbr_SN_HwVer_SwVer)

ANTMN

antennaModelNumber

ANTSN

antennaSerialNumber

BND<x>

band<x>

BMWD<x>

beamWidth<x>(degree)

GN<x>

gain0(dBi*1<x>)

SUBUNT

subUnitType

RXBMINF

rxBandMinFreq(kHz*100)

RXBMAXF

rxBandMaxFreq(kHz*100)

TXBMINF

txBandMinFreq(kHz*100)

TXBMAXF

txBandMaxFreq(kHz*100)

MAXGN

maxGain(dB*4)

MINGN

minGain(dB*4)

GNR

gainResolution(dB*4)

INSD

installDate

INSID

installerId

BTSID

baseStationId

SCID

sectorId

ANTB

antennaBearing(degree)

MTLT

mechanicalTilt(degree*10)

System Responses:
Operation Completed
None.
Operation Failed
None.
Application Guidelines:
None.
Example of Command Execution:
GET TMA: NAME=RACK:0/TMA:0, REQATTL=ALS&AST&AVS&OST&PRS&RELFUNCOBJ& ANTMN& ANTSN& BND0& BMWD0& GN0& BND1& BMWD1& GN1&
BND2& BMWD2& GN2& BND3& BMWD3& GN3& SUBUNT& RXBMINF& RXBMAXF&
TXBMINF& TXBMAXF& MAXGN& MINGN& GNR& INSD& INSID& BTSID& SCID&
ANTB& MTLT;

GET TMA PRODUCTINFO


GET TMA PRODUCTINFO

A50016-G5100-B333-04-7619

NAME=RACK:0..7/TMA:0..15;

Id:0900d805805959a8

543

TMA

BS-4x / 82 II / 240 / 241 / 240XL commands

Command Tree:
MANAGED-ELEMENT h BSS-EQUIPMENT h BTSEP h RACK h TMA h GET
TMA PRODUCTINFO
Applicability:
Phase 2 and Phase 3.
Visibility level: 0.
Command Description:
This command shows all the specific information related to TMA productinfo.
Long Names:
NAME

Address of the managed object

REQATTL

Required attribute list

System Responses:
Operation Completed
After command execution, a message of Changed Configuration Notification is displayed. A further message indicates the result of the operation. An example of get
product info command is the following:

JOB: 90
PC Time&Date: 15.05.2008 10:09:30 +02:00
NE Time&Date: 01.01.1990 00:05:05 +00:00
USER NAME:

User_Chris

COMMAND:

Get TMA PRODUCTINFO:NAME=RACK:0/TMA:0;

SW RELEASE:

01-04-19-01-01-MB_08-05-13

COMMAND RESULT: Operation successful

productInfo(prodNbr_SN_HwVer_SwVer) = "CS7299111.02; X9081012052;


HW_V_A06; FW_V02.02.00_BL_V02.02.00"

END OF OUTPUT FOR JOB 90

Binary Command

544

Id:0900d805805959a8

A50016-G5100-B333-04-7619

BS-4x / 82 II / 240 / 241 / 240XL commands

TMA

0d 00 80 ff 12 02 81 81 ab 1a 00 00 1a 01 a1

Binary Response

4a 00 80 00 02 12 01 82 ab 1a 00 00 a1 3e 43 53 37 32 39 39
31 31 31 2e 30 32 3b 20 58 39 30 38 31 30 31 32 30 35 32 3b
20 48 57 5f 56 5f 41 30 36 3b 20 46 57 5f 56 30 32 2e 30 32
2e 30 30 5f 42 4c 5f 56 30 32 2e 30 32 2e 30 30
Operation Failed
None.
Application Guidelines:
None.
Example of Command Execution:
GET TMA PRODUCTINFO: NAME=RACK:0TMA:0, REQATTL= PRDINF;

GETTEST TMA
GETTEST TMA

NAME=RACK:0..7/TMA:0..15;

Command Tree:
MANAGED-ELEMENT h BSS-EQUIPMENT h BTSEP h RACK h TMA h
GETTEST TMA
Applicability:
Phase 2 and Phase 3.
Visibility level: 0.
Command Description:
This command displays the attributes of the TMA test.
Long Names:
NAME

Address of the managed object

REQATTL

Required attribute list

System Responses:
Operation Completed
A message indicates the result of the operation. An example of gettest command is the
following:

A50016-G5100-B333-04-7619

Id:0900d805805959a8

545

TMA

BS-4x / 82 II / 240 / 241 / 240XL commands

JOB: 239
PC Time&Date: 14:50:09 03/23/2005
NE Time&Date: 00:17:47 09/15/2004
USER NAME:

User_Chris

COMMAND:

Gettest TMA:NAME=RACK:0/TMA:0;

SW RELEASE:

01-04-17-01-26-51_05-02-23

COMMAND RESULT: Operation successful


MOT = RACK:0/TMA:0
testMonitor =
phaseId = PreliminaryTestsTma
phaseStatus = Running
phaseId = CheckAlarmStatusTma
phaseStatus = Waiting
phaseId = EndTestTma
phaseStatus = Waiting
testOutcome = INCONCLUSIVE
testState = INITIALIZING
END OF OUTPUT FOR JOB 239
Operation Failed
The GET command has not been successfully executed. A general NACK will indicate
possible errors or a specific NACK strictly related to the single command is possible.
testMonitor
phaseId =
phaseStatus =

it is a list of all test phases related to the


selected object; for each phase the
related phaseStatus is provided (Passed,
Failed, Running or Waiting).

phaseId =
phaseStatus =
...
...
testOutcome

546

It represents the test result: it can be


Inconclusive (if the phases already
executed were successful) or Fail (if at
least one of the executed phases failed).

Id:0900d805805959a8

A50016-G5100-B333-04-7619

BS-4x / 82 II / 240 / 241 / 240XL commands

TMA

testState = Testing

It can assume one of the following values:


not_initialized, idle, initializing, suspended, testing, terminating and disabled.

Application Guidelines:
None.
Example of Command Execution:
Gettest TMA:NAME=RACK:0/TMA:0;

LOCK TMA
LOCK TMA

NAME=RACK:0..7/TMA:0..15;

Command Tree:
MANAGED-ELEMENT h BSS-EQUIPMENT h BTSEP h RACK h TMA h
LOCK TMA
Applicability:
Phase 2 and Phase 3.
Visibility level: 1.
Command Description:
This command changes the administrative state of the TMA (Tower Mounted Amplifier)
of the BTSE.
Long Names:
NAME

Address of the managed object

System Responses:
Operation Completed
The specified change of administrative state has been perfomed:
JOB: 8
PC Time&Date: 16:24:42 03/23/2005
NE Time&Date: 16:22:36 09/15/2004
USER NAME:

User_Chris

COMMAND:

Lock TMA:NAME=RACK:0/TMA:0;

SW RELEASE:

01-04-17-01-26-51_05-02-23

COMMAND RESULT: Operation successful


administrativeState = Locked
END OF OUTPUT FOR JOB 8

A50016-G5100-B333-04-7619

Id:0900d805805959a8

547

TMA

BS-4x / 82 II / 240 / 241 / 240XL commands

CHANGED STATE EVENT REPORT:


This provides information about the administrative state, the operational state and the
availability status every time a state change occurs:
JOB: 9
PC Time&Date: 16:24:42 03/23/2005
NE Time&Date: 16:22:36 09/15/2004
USER NAME:

User_Chris

SW RELEASE:

01-04-17-01-26-51_05-02-23

COMMAND RESULT: Operation successful


CHANGED STATE EVENT REPORT:
NAME = RACK:0/TMA:0
Administrative State = LOCKED
Notification Identifier = 461
END OF OUTPUT FOR JOB 9
Operation Failed
The specified change of administrative state has not been performed (e.g. the object is
redundant and its spare copy is disabled or already locked, a subordinate resource
cannot go into disabled state with "dependency" availability status).
Application Guidelines:
While a Frequency Redefinition procedure is ongoing, the lock/unlock of all HMO's
actually related to a TRX is forbidden because that could lead to minor SELIC problem
or major SELIC problem alarms.
Example of Command Execution:
Lock TMA:NAME=RACK:0/TMA:0;

PERFTEST TMA
PERFTEST TMA

NAME=RACK:0..7/TMA:0..15;

Command Tree:
MANAGED-ELEMENT h BSS-EQUIPMENT h BTSEP h RACK h TMA h
PERFTEST TMA

548

Id:0900d805805959a8

A50016-G5100-B333-04-7619

BS-4x / 82 II / 240 / 241 / 240XL commands

TMA

Applicability:
Phase 2 and Phase 3.
Visibility level: 1.
Command Description:
This command is used to start an asynchronous test in TMA.
Long Names:
NAME

Address of the managed object

System Responses:
Operation Completed
Test configuration has been set and the specified test has been started. The System
response will not be addressed to the MOT but to the object BTSE.
JOB: 240
PC Time&Date: 14:50:09 03/23/2005
NE Time&Date: 00:17:47 09/15/2004
USER NAME:

User_Chris

COMMAND:

Perftest TMA:NAME=RACK:0/TMA:0;

SW RELEASE:

01-04-17-01-26-51_05-02-23

COMMAND RESULT: Operation successful


MOT = RACK:0/TMA:0
tO = BTSETEST:1
END OF OUTPUT FOR JOB 240
JOB: 241
PC Time&Date: 14:50:09 03/23/2005
NE Time&Date: 00:17:47 09/15/2004
USER NAME:

User_Chris

SW RELEASE:

01-04-17-01-26-51_05-02-23

COMMAND RESULT: Operation successful


ChangedConfigurationNotification:

A50016-G5100-B333-04-7619

Id:0900d805805959a8

549

TMA

BS-4x / 82 II / 240 / 241 / 240XL commands

name = BTSETEST:1
ChangeInfo = created
END OF OUTPUT FOR JOB 241
JOB: 242
PC Time&Date: 14:50:12 03/23/2005
NE Time&Date: 00:17:51 09/15/2004
USER NAME:

User_Chris

SW RELEASE:

01-04-17-01-26-51_05-02-23

COMMAND RESULT: Operation successful


CHANGED STATE EVENT REPORT:
NAME = RACK:0/TMA:0
Operational State = ENABLED
Availability Status = NULL_value
Notification Identifier = 143
END OF OUTPUT FOR JOB 242
JOB: 243
PC Time&Date: 14:50:12 03/23/2005
NE Time&Date: 00:17:51 09/15/2004
USER NAME:

User_Chris

SW RELEASE:

01-04-17-01-26-51_05-02-23

COMMAND RESULT: Operation successful


Test Report:
name = BTSETEST:1
testOutcome = PASSED
testTermination = Normal
MOT = RACK:0/TMA:0
executedPhases =
PreliminaryTestsTma

550

Id:0900d805805959a8

A50016-G5100-B333-04-7619

BS-4x / 82 II / 240 / 241 / 240XL commands

TMA

CheckAlarmStatusTma
EndTestTma
END OF OUTPUT FOR JOB 243
JOB: 244
PC Time&Date: 14:50:09 03/23/2005
NE Time&Date: 00:17:47 09/15/2004
USER NAME:

User_Chris

SW RELEASE:

01-04-17-01-26-51_05-02-23

COMMAND RESULT: Operation successful


ChangedConfigurationNotification:
name = BTSETEST:1
ChangeInfo = deleted
END OF OUTPUT FOR JOB 244
The test results will be displayed at the end of the test phases.
Result TEST:
name =

TEST:<n>

testOutcome =

This field represents the test result; one of the following values can be displayed:
Pass

all the test phases are successfully


performed.

Inconclusive

the test is aborted by the system or


the test is terminated by the operator.

Fail

if at least one of the executed phases


fail.

mOts =

It is the identifier of the hardware object under test.

testTermination =

It specifies how the test is terminated, it can assume


the following values:
Normal

all the test phases are performed.

Abort

the test is aborted by system.

Cancel

the test is terminated by operator.

executedPhases

A50016-G5100-B333-04-7619

Id:0900d805805959a8

551

TMA

BS-4x / 82 II / 240 / 241 / 240XL commands

phaseId =
additionalWords =
....

It represents the list of the executed test phases (in


case of successful test result, all the test phases will
be listed).

failedPhases
phaseId =

It represents the list of the failed test phase; additional information is provided for each phase.

phaseId =
....
skippedPhases
phaseId =

It represents the list of the skipped phases; they are


displayed only for test stopped during it execution.

phaseId =
....
poprosedRepair Action
=

A list of most probable fail probable causes is shown


(max four messages)

Operation Failed
This NACK-message occurs in the following cases: Message cannot be performed, test
not supported, capacity restrictions, physical configuration cannot be performed, object
not locked.
Application Guidelines:

In phase 3 MO must be locked previous to the command execution

Example of Command Execution:


Perftest TMA:NAME=RACK:0/TMA:0;

STOPTEST TMA
STOPTEST TMA

NAME=RACK:0..7/TMA:0..15;

Command Tree:
MANAGED-ELEMENT h BSS-EQUIPMENT h BTSEP h RACK h TMA h
STOPTEST TMA
Applicability:
Phase 2 and Phase 3.
Visibility level: 1.
Command Description:
This command is used to stop a diagnostic previously started.
Long Names:
NAME

Address of the managed object

System Responses:
Operation Completed

552

Id:0900d805805959a8

A50016-G5100-B333-04-7619

BS-4x / 82 II / 240 / 241 / 240XL commands

TMA

Test has been stopped. The System Responses will not be addressed to the MOT but
to the object BTSEP.

Result TEST:
name =

TEST:<n>

testOutcome =

inconclusive

mOts =

It is the identifier of the hardware object under test.

testTermination =

Cancel

executedPhases
phaseId =

It represents the list of the executed test phases; the


list is not shown for test in the waiting list (queued).

...
.
failedPhases
phaseId =

It represents the list of the failed test phase;

phaseId =

additional information is provided for each phase.

....
skippedPhases
phaseId =

It represents the list of the skipped phases;the list is


not shown for test in the waiting list (queued).

phaseId =
Operation Failed

Test has not been stopped. This NACK-message can occur when the specified test is
not running or in case of test which cannot be stopped.
Application Guidelines:
None.
Example of Command Execution:
Stoptest TMA:NAME=RACK:0/TMA:0;

UNLOCK TMA
UNLOCK TMA

NAME=RACK:0..7/TMA:0..15;

Command Tree:
MANAGED-ELEMENT h BSS-EQUIPMENT h BTSEP h RACK h TMA h
UNLOCK TMA
Applicability:
Phase 2 and Phase 3.
Visibility level: 1.

A50016-G5100-B333-04-7619

Id:0900d805805959a8

553

TMA

BS-4x / 82 II / 240 / 241 / 240XL commands

Command Description:
This command changes the administrative state of the TMA (Tower Mounted Amplifier)
to the BTSE.
Long Names:
NAME

Address of the managed object

System Responses:
Operation Completed
The specified change of administrative state has been perfomed:
JOB: 10
PC Time&Date: 16:24:48 03/23/2005
NE Time&Date: 16:22:42 09/15/2004
USER NAME:

User_Chris

COMMAND:

Unlock TMA:NAME=RACK:0/TMA:0;

SW RELEASE:

01-04-17-01-26-51_05-02-23

COMMAND RESULT: Operation successful


administrativeState = Unlocked
END OF OUTPUT FOR JOB 10

CHANGED STATE EVENT REPORT:


This provides information about the administrative state, the operational state and the
availability status every time a state change occurs:
JOB: 11
PC Time&Date: 16:24:48 03/23/2005
NE Time&Date: 16:22:42 09/15/2004
USER NAME:

User_Chris

SW RELEASE:

01-04-17-01-26-51_05-02-23

COMMAND RESULT: Operation successful


CHANGED STATE EVENT REPORT:

554

Id:0900d805805959a8

A50016-G5100-B333-04-7619

BS-4x / 82 II / 240 / 241 / 240XL commands

TMA

NAME = RACK:0/TMA:0
Administrative State = UNLOCKED
Notification Identifier = 462
END OF OUTPUT FOR JOB 11
Operation Failed
The specified change of administrative state has not been performed.
Application Guidelines:
While a Frequency Redefinition procedure is ongoing, the lock/unlock of all HMO's
actually related to a TRX is forbidden because that could lead to minor SELIC problem
or major SELIC problem alarms.
Example of Command Execution:
Unlock TMA:NAME=RACK:0/TMA:0;

A50016-G5100-B333-04-7619

Id:0900d805805959a8

555

TRX

BS-4x / 82 II / 240 / 241 / 240XL commands

TRX
The TRX object locates the transceivers connected to a certain BSC.

GET TRX
GET TRX

NAME=BTS:0..11/TRX:0..23 [,REQATTL=ABISCH,
ANTHOPHW, AST, AVS, DLTESTFREQ, DMACFHSYID,
MOEC, OST, PWRRED, RADIOMG, RADIOMR, TEI, TESTMODE, TESTPWRRED, TRXAREA, TRXCPBL, TRXFREQ,
TRXMD];

Command Tree:
MANAGED-ELEMENT h BSS-FUNCTIONAL h BTSM h BTS h TRX h GET
TRX
Applicability:
Phase 3.
Visibility level: 0.
Command Description:
This command displays the attributes of the specified Transceiver.
Long Names:
NAME

Address of the managed object

REQATTL

Required attribute list

ABISCH

abisChannel

ANTHOPHW

antennaHoppingHw

AST

administrativeState

AVS

availabilityStatus

DLTESTFREQ

dlTestFrequency

DMACFHSYID

dmaCFHSyId

MOEC

memberOfEmergencyConfig

OST

operationalState

PWRRED

txPwrMaxReduction(*-2dB)

RADIOMG

radioMeasGran

RADIOMR

radioMeasRep

TEI

tei

TESTMODE

enableTestMode

TESTPWRRED

556

testPowerReduction

TRXAREA

trxArea

TRXCPBL

trxCapability

TRXFREQ

carrierFrequency

TRXMD

trxMode

Id:0900d805805959ab

A50016-G5100-B333-04-7619

BS-4x / 82 II / 240 / 241 / 240XL commands

TRX

System Responses:
Operation Completed
A message indicates the result of the operation. An example of get command is the following:
JOB: 18
PC Time&Date: 11:33:24 03/23/2005
NE Time&Date: 11:31:14 09/15/2004
USER NAME:

User_Christian

COMMAND:

Get TRX:NAME=BTS:0/TRX:0;

SW RELEASE:

01-04-17-01-26-51_05-02-23

COMMAND RESULT: Operation successful


abisChannel =
BPORT = 0
TSL = 1
SSL = NOT_USED
antennaHoppingHw =
administrativeState = Unlocked
availabilityStatus = Dependency
dlTestFrequency = NONE
enableTestMode = NONE
memberOfEmergencyConfig = TRUE
operationalState = DISABLED
txPwrMaxReduction(*-2dB) = 6
radioMeasGran = 1
radioMeasRep = ON
trxArea = NONE
carrierFrequency = 21
tei = 1
testPowerReduction = NONE
trxCapability = UNKNOWN
trxMode = GSM
END OF OUTPUT FOR JOB 18
Operation Failed

A50016-G5100-B333-04-7619

Id:0900d805805959ab

557

TRX

BS-4x / 82 II / 240 / 241 / 240XL commands

The GET command has not been successfully executed. A general NACK will indicate
possible errors or a specific NACK strictly related to the single command is possible.
Application Guidelines:

The TRX attribute trxCapability reflects the type of CU (GSM or EDGE) which is allocated to the TRX. If no CU isallocated, the attribute is set to "none". This static
assignment is not reasonable, because even if the TRX is disabled a CU may be still
allocated to the TRX (e.g. faulty combiner equipment)

Example of Command Execution:


Get TRX:NAME=BTS:0/TRX:0,REQATTL=ABISCH &ANTHOPHW &AST &AVS &DLTESTFREQ &DMACFHSYID &MOEC &OST &PWRRED &RADIOMG &RADIOMR &TEI
&TESTMODE &TESTPWRRED &TRXAREA &TRXCPBL &TRXFREQ &TRXMD;

GETRELATIONSHIP TRX
GETRELATIONSHIP
TRX

NAME=BTS:0..11/TRX:0..23;

Command Tree:
MANAGED-ELEMENT h BSS-FUNCTIONAL h BTSM h BTS h TRX h
GETRELATIONSHIP TRX
Applicability:
Phase 3.
Visibility level: 0.
Command Description:
This command displays the attributes of the specified Transceiver.
Long Names:
NAME

Address of the managed object

REQATTL

Required attribute list

System Responses:
Operation Completed
A message indicates the result of the operation. An example of getrelationship
command is the following:
JOB: 161
PC Time&Date: 12:04:08 03/23/2005
NE Time&Date: 13:05:43 09/15/2004
USER NAME:

User_Christian

COMMAND:

Getrelationship TRX:NAME=BTS:0/TRX:0;

SW RELEASE:

558

01-04-17-01-26-51_05-02-23

Id:0900d805805959ab

A50016-G5100-B333-04-7619

BS-4x / 82 II / 240 / 241 / 240XL commands

TRX

COMMAND RESULT: Operation successful


relatedEquipObjects =
RACK:0/COBA:0
RACK:0/CU:3
RACK:0/DUVSWR:3
RACK:0/DULNA:2
RACK:0/TMA:2
RACK:0/DUDCTMA:2
RACK:0/DULNA:3
RACK:0/TMA:3
RACK:0/DUDCTMA:3
END OF OUTPUT FOR JOB 161
Operation Failed
The GET command has not been successfully executed. A general NACK will indicate
possible errors or a specific NACK strictly related to the single command is possible.
Application Guidelines:
None.
Example of Command Execution:
Getrelationship TRX:NAME=BTS:0/TRX:0;

A50016-G5100-B333-04-7619

Id:0900d805805959ab

559

XCONNECT

BS-4x / 82 II / 240 / 241 / 240XL commands

XCONNECT
The XCONNECT object represents an hardware BTSE object that enables the crossconnection between PCM timeslots of different ports with a BTSE.

CREATE XCONNECT
CREATE XCONNECT

NAME=XCONNECT:0..7 [,MPTSLXX=];

Command Tree:
MANAGED-ELEMENT h BSS-EQUIPMENT h BTSEP h XCONNECT h
CREATE XCONNECT
Applicability:
Phase 2 and Phase 3.
Visibility level: 2.
Command Description:
This command provides the XCONNECT (Multidrop-Star CrossConnect) of 64Kbit/s
timeslots and additionally a mapping of the timeslot position is provided. This command
allows also the PCM30/24 conversion.
Long Names:
NAME

Address of the managed object

MPTSLXX

mappingTSLXX

System Responses:
Operation Completed
After command execution, a message of Changed Configuration Notification is displayed.
A further message indicates the result of the operation. An example of create command
is the following:
JOB: 15
PC Time&Date: 12:05:31 03/23/2005
NE Time&Date: 12:03:22 09/15/2004
USER NAME:

User_NSN

SW RELEASE:

01-04-17-01-26-51_05-02-23

COMMAND RESULT: Operation successful


ChangedConfigurationNotification:
name = XCONNECT:0
ChangeInfo = created

560

Id:0900d805805959ad

A50016-G5100-B333-04-7619

BS-4x / 82 II / 240 / 241 / 240XL commands

XCONNECT

END OF OUTPUT FOR JOB 15


JOB: 16
PC Time&Date: 12:05:31 03/23/2005
NE Time&Date: 12:03:22 09/15/2004
USER NAME:

User_NSN

COMMAND:

Create XCONNECT:NAME=XCONNECT:0;

SW RELEASE:

01-04-17-01-26-51_05-02-23

COMMAND RESULT: Operation successful


END OF OUTPUT FOR JOB 16
Operation Failed
The specified Object has not been created. In addition to the general NACK causes, a
specific NACK cause, which indicates that the command is inconsistent with the
physical configuration, is possible. An example is the following:
JOB: 81
PC Time&Date: 16:37:54 03/23/2005
NE Time&Date: 16:35:47 09/15/2004
USER NAME:

User_NSN

COMMAND:

Create XCONNECT:NAME=XCONNECT:0;

SW RELEASE:

01-04-17-01-26-51_05-02-23

COMMAND RESULT: OPERATION FAILED


Object instance unknown (-9)
END OF OUTPUT FOR JOB 81
Application Guidelines:

A XConnect instance is always related to a primary BPort instance. So this target


BPort instance must be created before and configured as StarX

A cross connection can only be established between a primary circuit and a secondary circuit, but not between two primary circuits or secondary circuits

A secondary circuit can only be used for cross connect functionality

A remapping can only be performed for a primary circuit. Only for traffic or signalling
timeslots the remapping is applicable, but not for a layer1 control timeslot

A50016-G5100-B333-04-7619

Id:0900d805805959ad

561

XCONNECT

BS-4x / 82 II / 240 / 241 / 240XL commands

TS 0 means to delete the TS of the XConnect

Example of Command Execution:


Create XCONNECT:NAME=XCONNECT:0,MPTSL01=0-0;

DELETE XCONNECT
DELETE XCONNECT

NAME=XCONNECT:0..7;

Command Tree:
MANAGED-ELEMENT h BSS-EQUIPMENT h BTSEP h XCONNECT h
DELETE XCONNECT
Applicability:
Phase 2 and Phase 3.
Visibility level: 2.
Command Description:
This command deletes the XCONNECT (Multidrop-Star CrossConnect) of 64Kbit/s
timeslots from the BTSE data base.
Long Names:
NAME

Address of the managed object

System Responses:
Operation Completed
After command execution, a message of Changed Configuration Notification is displayed. A further message indicates the result of the operation. An example of delete
command is the following:
JOB: 25
PC Time&Date: 12:07:08 03/23/2005
NE Time&Date: 12:04:59 09/15/2004
USER NAME:

User_NSN

SW RELEASE:

01-04-17-01-26-51_05-02-23

COMMAND RESULT: Operation successful


ChangedConfigurationNotification:
name = XCONNECT:0
ChangeInfo = deleted
END OF OUTPUT FOR JOB 25

562

Id:0900d805805959ad

A50016-G5100-B333-04-7619

BS-4x / 82 II / 240 / 241 / 240XL commands

XCONNECT

JOB: 26
PC Time&Date: 12:07:08 03/23/2005
NE Time&Date: 12:04:59 09/15/2004
USER NAME:

User_NSN

COMMAND:

Delete XCONNECT:NAME=XCONNECT:0;

SW RELEASE:

01-04-17-01-26-51_05-02-23

COMMAND RESULT: Operation successful


END OF OUTPUT FOR JOB 26
Operation Failed
The specified Object has not been deleted. Additionally to the general NACK causes, a
specific NACK cause, meaning that the command is inconsistent with physical configuration, is possible.
Application Guidelines:

Deletion of a secondary circuit is only allowed, if there are no cross connections


established to the related BPort instance

Deletion of XConnect is possible in phase 2 or phase 3

In phase 3 the XConnect object must be locked before it can be deleted

Example of Command Execution:


Delete XCONNECT:NAME=XCONNECT:0;

GET XCONNECT
GET XCONNECT

NAME=XCONNECT:0..7 [,REQATTL=ALS, AST, AVS,


MPTSLXX, OST, PRS, RELFUNCOBJ];

Command Tree:
MANAGED-ELEMENT h BSS-EQUIPMENT h BTSEP h XCONNECT h GET
XCONNECT
Applicability:
Phase 2 and Phase 3.
Visibility level: 0.
Command Description:
This command displays the attributes of XCONNECT (Multidrop-Star CrossConnect)
and additionally of the timeslot position mapping.
Long Names:
NAME

A50016-G5100-B333-04-7619

Address of the managed object

Id:0900d805805959ad

563

XCONNECT

BS-4x / 82 II / 240 / 241 / 240XL commands

REQATTL

Required attribute list

ALS

alarmStatus

AST

administrativeState

AVS

availabilityStatus

MPTSLXX

mappingTSLXX

OST

operationalState

PRS

proceduralStatus

RELFUNCOBJ

relatedFuncObjects

System Responses:
Operation Completed
A message indicates the result of the operation. An example of get command is the following:
JOB: 17
PC Time&Date: 12:05:47 03/23/2005
NE Time&Date: 12:03:37 09/15/2004
USER NAME:

User_NSN

COMMAND:

Get XCONNECT:NAME=XCONNECT:0;

SW RELEASE:

01-04-17-01-26-51_05-02-23

COMMAND RESULT: Operation successful


alarmStatus = CLEARED
administrativeState = Unlocked
availabilityStatus = NULL
mappingTSL01 =
targetBport = 0
targetTSL = 0
mappingTSL02 =
targetBport = 0
targetTSL = 0
mappingTSL03 =
targetBport = 0
targetTSL = 0
mappingTSL04 =
targetBport = 0
targetTSL = 0
mappingTSL05 =

564

Id:0900d805805959ad

A50016-G5100-B333-04-7619

BS-4x / 82 II / 240 / 241 / 240XL commands

XCONNECT

targetBport = 0
targetTSL = 0
mappingTSL06 =
targetBport = 0
targetTSL = 0
mappingTSL07 =
targetBport = 0
targetTSL = 0
mappingTSL08 =
targetBport = 0
targetTSL = 0
mappingTSL09 =
targetBport = 0
targetTSL = 0
mappingTSL10 =
targetBport = 0
targetTSL = 0
mappingTSL11 =
targetBport = 0
targetTSL = 0
JOB: 17
mappingTSL12 =
targetBport = 0
targetTSL = 0
mappingTSL13 =
targetBport = 0
targetTSL = 0
mappingTSL14 =
targetBport = 0
targetTSL = 0
mappingTSL15 =
targetBport = 0
targetTSL = 0
mappingTSL16 =
targetBport = 0
targetTSL = 0
mappingTSL17 =
targetBport = 0
targetTSL = 0

A50016-G5100-B333-04-7619

Id:0900d805805959ad

565

XCONNECT

BS-4x / 82 II / 240 / 241 / 240XL commands

mappingTSL18 =
targetBport = 0
targetTSL = 0
mappingTSL19 =
targetBport = 0
targetTSL = 0
mappingTSL20 =
targetBport = 0
targetTSL = 0
mappingTSL21 =
targetBport = 0
targetTSL = 0
mappingTSL22 =
targetBport = 0
targetTSL = 0
mappingTSL23 =
targetBport = 0
targetTSL = 0
mappingTSL24 =
targetBport = 0
targetTSL = 0
mappingTSL25 =
targetBport = 0
targetTSL = 0
mappingTSL26 =
targetBport = 0
targetTSL = 0
mappingTSL27 =
targetBport = 0
targetTSL = 0
JOB: 17
mappingTSL28 =
targetBport = 0
targetTSL = 0
mappingTSL29 =
targetBport = 0
targetTSL = 0
mappingTSL30 =
targetBport = 0

566

Id:0900d805805959ad

A50016-G5100-B333-04-7619

BS-4x / 82 II / 240 / 241 / 240XL commands

XCONNECT

targetTSL = 0
mappingTSL31 =
targetBport = 0
targetTSL = 0
operationalState = ENABLED
proceduralStatus = NULL
relatedFuncObjects =
END OF OUTPUT FOR JOB 17
Operation Failed
The GET command has not been successfully executed. A general NACK will indicate
possible errors or a specific NACK strictly related to the single command is possible.
Application Guidelines:
None.
Example of Command Execution:
Get XCONNECT:NAME=XCONNECT:0,REQATTL=ALS&AST&AVS&MPTSL01&MPTSL02&MPTSL03&MPTSL04&M
PTSL05&MPTSL06&MPTSL07&MPTSL08&MPTSL09&MPTSL10&MPTSL11&MPTS
L12&MPTSL13&MPTSL14&MPTSL15&MPTSL16&MPTSL17&MPTSL18&MPTSL19&
MPTSL20&MPTSL21&MPTSL22&MPTSL23&MPTSL24&MPTSL25&MPTSL26&MPT
SL27&MPTSL28&MPTSL29&MPTSL30&MPTSL31&OST&PRS&RELFUNCOBJ;

LOCK XCONNECT
LOCK XCONNECT

NAME=XCONNECT:0..7;

Command Tree:
MANAGED-ELEMENT h BSS-EQUIPMENT h BTSEP h XCONNECT h LOCK
XCONNECT
Applicability:
Phase 2 and Phase 3.
Visibility level: 1.
Command Description:
This command changes the administrative state of the XCONNECT (Multidrop-Star
CrossConnect).
Long Names:
NAME

Address of the managed object

System Responses:
Operation Completed
The specified change of administrative state has been perfomed:

A50016-G5100-B333-04-7619

Id:0900d805805959ad

567

XCONNECT

BS-4x / 82 II / 240 / 241 / 240XL commands

JOB: 19
PC Time&Date: 12:06:07 03/23/2005
NE Time&Date: 12:03:58 09/15/2004
USER NAME:

User_NSN

COMMAND:

Lock XCONNECT:NAME=XCONNECT:0;

SW RELEASE:

01-04-17-01-26-51_05-02-23

COMMAND RESULT: Operation successful


administrativeState = Locked
END OF OUTPUT FOR JOB 19

CHANGED STATE EVENT REPORT:


This provides information about the administrative state, the operational state and the
availability status every time a state change occurs:
JOB: 18
PC Time&Date: 12:06:02 03/23/2005
NE Time&Date: 12:03:54 09/15/2004
USER NAME:

User_NSN

SW RELEASE:

01-04-17-01-26-51_05-02-23

COMMAND RESULT: Operation successful


CHANGED STATE EVENT REPORT:
NAME = XCONNECT:0
Administrative State = LOCKED
Notification Identifier = 3151
END OF OUTPUT FOR JOB 18
Operation Failed
The specified change of administrative state has not been performed (e.g. the object is
redundant and its spare copy is disabled or already locked, a subordinate resource
cannot go into disabled state with "dependency" availability status).

568

Id:0900d805805959ad

A50016-G5100-B333-04-7619

BS-4x / 82 II / 240 / 241 / 240XL commands

XCONNECT

Application Guidelines:

This command has no effect on the established connections

Example of Command Execution:


Lock XCONNECT:NAME=XCONNECT:0;

SET XCONNECT
SET XCONNECT

NAME=XCONNECT:0..7 [,MPTSLXX=];

Command Tree:
MANAGED-ELEMENT h BSS-EQUIPMENT h BTSEP h XCONNECT h SET
XCONNECT
Applicability:
Phase 2 and Phase 3.
Visibility level: 2.
Command Description:
This command sets the attributes for the mapping of the XCONNECT (Multidrop-Star
CrossConnect) 64Kbit/s timeslot position.
Long Names:
NAME

Address of the managed object

MPTSLXX

mappingTSLXX

System Responses:
Operation Completed
The specified attribute has been set. In addition, a Changed Attribute Event Report indicates that the command has been successfully executed:
JOB: 20
PC Time&Date: 12:06:33 03/23/2005
NE Time&Date: 12:04:23 09/15/2004
USER NAME:

User_NSN

COMMAND:

Set XCONNECT:NAME=XCONNECT:0;

SW RELEASE:

01-04-17-01-26-51_05-02-23

COMMAND RESULT: SET-NACK


Operation successful
END OF OUTPUT FOR JOB 20
Operation Failed

A50016-G5100-B333-04-7619

Id:0900d805805959ad

569

XCONNECT

BS-4x / 82 II / 240 / 241 / 240XL commands

The specified Object has not been created. In addition to the general NACK causes, a
specific NACK cause, which indicates that the command is inconsistent with the
physical configuration, is possible.
Application Guidelines:

A secondary circuit cannot be changed to a primary circuit and vice versa via a SET
command

A remapping can only be performed for a primary circuit

Only for traffic or signalling timeslots the remapping is applicable, but not for a layer1
control timeslot

Example of Command Execution:


Set XCONNECT:NAME=XCONNECT:0,MPTSL01=0-0;

UNLOCK XCONNECT
UNLOCK XCONNECT

NAME=XCONNECT:0..7;

Command Tree:
MANAGED-ELEMENT h BSS-EQUIPMENT h BTSEP h XCONNECT h
UNLOCK XCONNECT
Applicability:
Phase 2 and Phase 3.
Visibility level: 1.
Command Description:
This command changes the administrative state of the XCONNECT (Multidrop-Star
CrossConnect).
Long Names:
NAME

Address of the managed object

System Responses:
Operation Completed
The specified change of administrative state has been perfomed:
JOB: 22
PC Time&Date: 12:06:46 03/23/2005
NE Time&Date: 12:04:37 09/15/2004
USER NAME:

User_NSN

COMMAND:

Unlock XCONNECT:NAME=XCONNECT:0;

SW RELEASE:

01-04-17-01-26-51_05-02-23

COMMAND RESULT: Operation successful

570

Id:0900d805805959ad

A50016-G5100-B333-04-7619

BS-4x / 82 II / 240 / 241 / 240XL commands

XCONNECT

administrativeState = Unlocked
END OF OUTPUT FOR JOB 22

CHANGED STATE EVENT REPORT:


This provides information about the administrative state, the operational state and the
availability status every time a state change occurs:
JOB: 21
PC Time&Date: 12:06:46 03/23/2005
NE Time&Date: 12:04:37 09/15/2004
USER NAME:

User_NSN

SW RELEASE:

01-04-17-01-26-51_05-02-23

COMMAND RESULT: Operation successful


CHANGED STATE EVENT REPORT:
NAME = XCONNECT:0
Administrative State = UNLOCKED
Notification Identifier = 3154
END OF OUTPUT FOR JOB 21
Operation Failed
The specified change of administrative state has not been performed.
Application Guidelines:

This command has no effect on the established connections

Example of Command Execution:


Unlock XCONNECT:NAME=XCONNECT:0;

A50016-G5100-B333-04-7619

Id:0900d805805959ad

571

Parameters/attributes in alphabetical order

BS-4x / 82 II / 240 / 241 / 240XL commands

3 Parameters/attributes in alphabetical order


g Please note that the abbreviations marked with an * are not real parameters.

572

Id:0900d80580248208

A50016-G5100-B333-04-7619

BS-4x / 82 II / 240 / 241 / 240XL commands

a
ABISCH
abisChannel
This attribute identifies the Timeslot Number and Sublot Number allocated on the Abisinterface.This attribute exists only for TRX. The attribute refers to a radio signalling link
(RSL): it indicates just the default channel for the RSL - a more actual information is
reflected in the object LAPDLE.
Validity Range
BPORT

(TRX)

00-07

(for BS-82 II only, BPortNumber 00-03 is allowed)

TSL

1-31 (PCM30)

SSL

SSL0

a (bits 8,7)

SSL1

b (bits 6,5)

SSL2

c (bits 4,3)

SSL3

d (bits 2,1)

1-24 (PCM24)

NOT_USED

64 kb/s signalling

(the value NOT_USED reflects at the MMI that RSL operates with 64 kb/s)

Default Value
None.
Contained in the following commands:
GET TRX

ABISLKSAT
sAbisLinkSatellited
The attribute informs the BTSE SW about the presence of a satellite on the Asub interface.
Validity Range
terrestrialConnection
satelliteConnection
Default Value
terrestrialConnection
Contained in the following commands:
GET BTSM NOSWL, SET BTSM

ABISTIME
sAbisExternalTime

A50016-G5100-B333-04-7619

Id:0900d80580627a8f

573

BS-4x / 82 II / 240 / 241 / 240XL commands

This attribute provides the time-of-day time of the BTSE. This attribute functions as a
reference for all time stamp activities in the BTSE. A daily update of the attribute is performed via Abis. Additionally the attribute is update after each successful Abis-alignment.

Validity Range
In commands GET BTSM NOSWL:
<ANY>
<NULL>
In commands SET BTSM:
year

1992 - 2099

month

1 - 12

day

1 - 31

hour

0 - 23

min

0 - 59

sec

0 - 59

offsetHour

-12 - 14

offsetMinute

0 - 45

Default Value
None.
Contained in the following commands:
GET BTSM NOSWL, SET BTSM

ACBQPFF
acBQPFgtFac
acBQPFgtFac defines the forgetting factor for the time exponential filter used for BQP
averaging. A change of the attribute becomes effective at the next AC period.
Validity Range
0.1 - 1.0

10 entries can be selected:


- 1 corresponds to the attribute value 0.1
- 10 corresponds to the attribute value 1.0

Default Value
0.2
Contained in the following commands:
GET BTS

574

Id:0900d80580627a8f

A50016-G5100-B333-04-7619

BS-4x / 82 II / 240 / 241 / 240XL commands

ACBQPMAX
acBQPMax(%)
acBQPMax specifies the maximum tolerated Bad Quality Probability (outage probability)
in the cell. If e.g. acFERMax is 5% and acBQPMax is 10% it indicates that more than
10% of the speech samples having a FER with more than 5% is not acceptable. A
change of the attribute becomes effective at the next AC period.
Validity Range
2 - 10

9 entries can be selected:


- 2 corresponds to the attribute value 2%
- 10 corresponds to the attribute value 10%

Default Value
5%
Contained in the following commands:
GET BTS

ACEFLFF
acEFLFgtFac
acEFLFgtFac defines the forgetting factor for the exponential filter used for fractional
load averaging. A change of the attribute becomes effective at the next AC period.
Validity Range
0.02 - 0.20

10 entries can be selected:


- 1 corresponds to the attribute value 0.02
- 10 corresponds to the attribute value 0.20

Default Value
0.04
Contained in the following commands:
GET BTS

ACFERMAX
acFERMax(%)
acFERMax is a criterion for the speech quality in terms of frame erasure rate (FER).
acFERMax specifies the maximum tolerated FER for speech samples taken over 4
SACCH periods, e.g. acFERMax = 5.0% requires that not more than 5% bad speech
frames are allowed in a sample taken over 4 SACCH periods, i.e. the FER over the
sampling period of 4 SACCH frames shall be less or equal to 5%. In other words, if the
percentage of bad frames (FER > acFERMax) is greater than acFERMax the respective

A50016-G5100-B333-04-7619

Id:0900d80580627a8f

575

BS-4x / 82 II / 240 / 241 / 240XL commands

sample will increase the BQP. A change of the attribute becomes effective at the next
AC period.
Validity Range
1.0 - 10.0

19 entries can be selected:


- 1 corresponds to the attribute value 1.0%
- 19 corresponds to the attribute value 10.0%
(the step size is 0.5%)

Default Value
5.0%
Contained in the following commands:
GET BTS

ACLNKTYP
acLinkType
acLinkType defines the type of samples to be collected. It also specifies the way they
will be used for the BQP evaluation.
acLinkType == 0 and acLinkType == 2 require EMR (ENHANCED MEASUREMENT
REPORTING). A change of the attribute becomes effective at the next AC period.
Validity Range
UL_AND_DL_SAMPLES_S
EPARATELY
UL_SAMPLES_ONLY
UL_AND_DL_SAMPLES_
COMMONLY
Default Value
UL_SAMPLES_ONLY (Collect and evaluate UL samples only)
Contained in the following commands:
GET BTS

ACMAXEFLDMA
acMaxEFLDMA(%)
acMaxEFLDMA specifies the maximum effective frequency load (EFL). The value is
valid for each DMA layer of the cell. A change of the attribute becomes effective at the
next AC period.
Validity Range
10%

576

Id:0900d80580627a8f

A50016-G5100-B333-04-7619

BS-4x / 82 II / 240 / 241 / 240XL commands

15%
.

100%
(starting from 10, 19 entries could be selected, with step size = 5)
Default Value
50%
Contained in the following commands:
GET BTS

ACMINEFLDMA
acMinEFLDMA(%)
acMinEFLDMA specifies the minimum EFL. The value is valid for each DMA layer of the
cell. A change of the attribute becomes effective at the next AC period.
Validity Range
5

5%

10 10%
..
..
50

50%

(starting from 5, the entries could be selected, with step size=5)


Default Value
50%
Contained in the following commands:
GET BTS

ACONN
alarmConnector
The MDUX alarm line can be assigned to any ACTC alarm connector which is freely
configurable via an ENVABTSE object. The relative ENVABTSE must not be created if
the related connector is used for the MDUX.
Validity Range
ENVA0
ENVA1
...

A50016-G5100-B333-04-7619

Id:0900d80580627a8f

577

BS-4x / 82 II / 240 / 241 / 240XL commands

ENVA8
Default Value
None.
Contained in the following commands:
CREATE BCOM, GET BCOM, SET BCOM

ACPER
acPeriod
acPeriod specifies the time/length of every Admission Control Period in measurement
reporting periods (480 milliseconds) (e.g. 100 periods) used for the periodic AC evaluation and the periodic reporting to the BSC via the 'Radio Link Admission Control
Message. A change of the attribute becomes effective at the next AC period.
Validity Range
20

20 measurement reporting periods

24

24 measurement reporting periods

measurement reporting periods

measurement reporting periods

396 396 measurement reporting periods


400 400 measurement reporting periods
(96 possible entries with step size equal to 4)
Default Value
120 measurement reporting periods
Contained in the following commands:
GET BTS

ACTVINC
activationIncluded
This attribute indicates whether the installed FW is be activated automatically by LRU
reset or not.
Validity Range
TRUE
FALSE
Default Value
None.
Contained in the following commands:
FWUPGRADE BTSM

578

Id:0900d80580627a8f

A50016-G5100-B333-04-7619

BS-4x / 82 II / 240 / 241 / 240XL commands

ALIGCOBA
alignedCoba
The attribute indicates that the flash content is potentially incomplete due to a previously
interrupted
COBA alignment. 16
The alignedCOBA attribute is automatically set to 'False' by the BTSE if the passive
COBA could not be aligned. If the attribute is set to TRUE by the operator (to indicate,
that he checked and, if necessary, corrected the Flash-contents to his needs) the
according alarm is ceased.
The setting to 'False' via command is rejected.
Validity Range
TRUE
FALSE
Default Value
TRUE
Contained in the following commands:
GET BTSEP NOSWL, SET BTSEP

ALRMCLET
alarmClearanceTime
An alarm must not be active at least for this time before it is ceased. The time is
expressed by the number of polling periods (1 s).
Validity Range
1 - 20
Default Value
10
Contained in the following commands:
CREATE CESTUNNEL, GET CESTUNNEL, SET CESTUNNEL

ALRMCOUNTER
alarmCount
The BTSE supports a filter mechanism for the following failure event
reports related to pcm line problems (and is valid for all created
BPORT instances).
1. "lower BER threshold exceeded"

A50016-G5100-B333-04-7619

Id:0900d80580627a8f

579

BS-4x / 82 II / 240 / 241 / 240XL commands

2. "external signal absence"


3. "AIS alarm"
4. "frame alignment loss"
5. "higher BER threshold exceeded"
6. "remote alarm"
The following filter mechanism is applied for the failure event reports
1-6 listed above.
An alarm is generated because of 2 possible events:
a) If it is found active for a time interval equal or greater than
alarmTiming2.
b) If it is found active with a duration less than alarmTiming2 but it is
found active at least as often as alarmCount in a time interval equal
to alarmTiming3. The number of the alarm is incremented every time
a transition 'not active' to 'active' is detected.
The alarm contains an information in the additional information
parameter whether it was detected due to event a) or event b).
An active alarm is cleared if no alarm is found for a time interval
equal to alarmTiming1.
Validity Range
1 - 254
Default Value
32
Contained in the following commands:
CREATE COBA, GET COBA, SET COBA

ALRMPERT
alarmPersistencyTime
All alarms which could toggle must persist at least for this time before an alarm is
reported. The time is expressed by the number of polling periods (1 s).
Validity Range
1 - 20
Default Value
3
Contained in the following commands:
CREATE CESTUNNEL, GET CESTUNNEL, SET CESTUNNEL

580

Id:0900d80580627a8f

A50016-G5100-B333-04-7619

BS-4x / 82 II / 240 / 241 / 240XL commands

ALRMSEVXXX
alarmSeverityXXX
This attribute defines the severity that the BTSE SW has to use for
the given type of HW board in case of state transitions from 'enabled'
to 'disabled failed'.
A change of the attribute becomes effective with the start of a new
failure, i.e. if the attribute is changed and a failure is still pending the
change of the attribute will not trigger a 'failure ceased' failure event
report together with a failure event report with the new alarmSeverityXXX.
List of BS240, BS24XL, BS241, BS40, BS41 HW:
ALRMSEVACDC, ALRMSEVACT, ALRMSEVBATTERY, ALRMSEVBCOMP,
ALRMSEVCOBA, ALRMSEVCOSA, ALRMSEVCU,
ALRMSEVDIDCTMA, ALRMSEVDILNA, ALRMSEVDUAMCO,
ALRMSEVDUDCTMA,
ALRMSEVDULNA, ALRMSEVDUVSWR, ALRMSEVF6DCTMA,
ALRMSEVF6LNA, ALRMSEVF6TNFP, ALRMSEVF6VSWRP,
ALRMSEVFANP, ALRMSEVFCUMAIN,ALRMSEVFCUTR,
ALRMSEVFTNFP, ALRMSEVFVSWRP, ALRMSEVTMA
Validity Range
CRITICAL
MAJOR
MINOR
DEFAULT_DB
Default Value
DEFAULT_DB
Contained in the following commands:
GET BTSEP NOSWL, SET BTSEP

ALRMT1/2/3
alarmTiming1(sec)/2(sec)/3(unit of 5 minutes)
The attribute value is valid for all created BPORT instances.

A50016-G5100-B333-04-7619

Id:0900d80580627a8f

581

BS-4x / 82 II / 240 / 241 / 240XL commands

The BTSE supports a filter mechanism for the following failure event
reports related to pcm line problems:
1. "lower BER threshold exceeded"
2. "external signal absence"
3. "AIS alarm"
4. "frame alignment loss"
5. "higher BER threshold exceeded"
6. "remote alarm"
The following filter mechanism is applied for the failure event reports
listed above.
An alarm is generated because of 2 possible events:
a) If it is found active for a time interval equal or greater than
alarmTiming2.
b) If it is found active with a duration less than alarmTiming2 but it is
found active at least as often as alarmCount in a time interval equal
to alarmTiming3. The number of the alarm is incremented every time
a transition 'not active' to 'active' is detected.
- The alarm contains an information in the additional information
parameter whether it was detected due to event a) or event b).
- An active alarm is cleared if no alarm is found for a time interval
equal to alarmTiming1.
Validity Range

g The alrmt1 and alrmt2 attributes are indicated in seconds (with 1 second step size).
The alrmt3 attribute is indicated in minutes (with 5 minutes steps size).
1 - 254
Default Value
alrmt1 : 20 seconds
alrmt1 : 1 second
alrmt1 : 1 (5 minutes)
Contained in the following commands:
CREATE COBA, GET COBA, SET COBA

ALS
alarmStatus
This attribute shows the highest severity of all active alarm conditions related to the
managed object. In case of summarization objects a proprietary semantics is used.
Validity Range
CLEARED

582

Id:0900d80580627a8f

A50016-G5100-B333-04-7619

BS-4x / 82 II / 240 / 241 / 240XL commands

MINOR
MAJOR
CRITICAL
Default Value
CLEARED
Contained in the following commands:
GET ACDCP, GET ACT, GET BATTERY, GET BCOM, GET BPORT, GET BTSEP
NOSWL, GET CESPW, GET CESTUNNEL, GET COBA, GET COBAETHINTF, GET
COSA, GET CU, GET DIDCTMA, GET DILNA, GET DUAMCO, GET DUDCTMA,
GET DULNA, GET DUVSWR, GET ENVABTSE, GET ETHCON, GET ETHPORT,
GET F6DCTMA, GET F6LNA, GET F6TNFP, GET F6VSWRP, GET FANP, GET
FCUMAIN, GET FCUTR, GET FTNFP, GET FVSWRP, GET LAPDLE, GET RACK,
GET SYNCBTSE, GET TMA, GET XCONNECT

AMRLKAT
aMRLinkAdapTuning
This parameter is used by the AMR Uplink Codec Mode Adaptation in the BTS. It tunes
the transition between codec modes determined by internal thresholds. A value higher
than the default shifts the transition towards higher carrier-to-interferer or signal-to-noise
ratios. A value lower than the default has the opposite effect. The step size is 0,1dB.
Adaptation of AMR Half Rate and AMR Full Rate is affected simultaneously. All possible
transitions between modes are generally shifted by the same amount.
However, to account for a limited range of the underlying measurements, shifts of transitions near the upper range limit tend to saturate when shifted closer to the limit. The
default value is the optimum setting and normally requires no modification.
Validity Range
<0x00...0xC8>
(i.e. -10 dB to 10 dB), step: 1 (0.1 dB), as follows:
0 - 200

00

-100

01

-99

99

-1

100

101

+1

200

+100

(-10 dB)

(0 dB)

(10 dB)

The values have the following meaning:


0x00 -10 dB
0x01 -9.9 dB

A50016-G5100-B333-04-7619

Id:0900d80580627a8f

583

BS-4x / 82 II / 240 / 241 / 240XL commands

..
0x63 -0.1 dB
0x64 0 dB
..
0xC8 10 dB
Default Value
0 dB
Contained in the following commands:
GET BTS

AMRLKATWFS
aMRLinkAdapTuningWFS(dB)
Uplink codec mode adaptation for TCH/WFS.
Validity Range
-10.0 - 10.0
Default Value
None.
Contained in the following commands:
GET BTS

ANT<x>CELLNO
ant<x>CellNumber
This attribute specifies the number of the cell. The value corresponds to the instance
number of the object BTS. The attribute can be only modified if no wiring destinations
are configured.
Note: <x> ... <0...5>
so the names of the attributes read:
GUI: ant0CellNumber

CLI: ANT0CELLNO

ant1CellNumber

ANT1CELLNO

ant2CellNumber

ANT2CELLNO

ant3CellNumber

ANT3CELLNO

ant4CellNumber

ANT4CELLNO

ant5CellNumber

ANT5CELLNO

g With the SET BCOM command it is possible to "delete" the parameters setting the
value "NULL", not all together but first the wiring date and in a second command the
cell parameters (see Application Guidelines: of SET BCOM).

584

Id:0900d80580627a8f

A50016-G5100-B333-04-7619

BS-4x / 82 II / 240 / 241 / 240XL commands

Validity Range
In commands CREATE BCOM, SET BCOM:
0 - 11
<NULL>
In commands GET BCOM:
<ANY>
Default Value
In moc(s) BCOM:
None.
In moc(s) BCOM:
NULL
Contained in the following commands:
CREATE BCOM, GET BCOM, SET BCOM

ANT<x>SCNRX
ant<x>SecondCellNumberRx
This attribute is available only for the object class BCOM, and only if "typeOfBTSE" is
set to "BS288". This attribute allows sharing of one antenna by 2 cells for receive diversity.
Note: <x> ... <0...5>
so the names of the attributes read:
GUI: ant0SecondCellNumberRx CLI: ANT0SCNRX
ant1SecondCellNumberRx

ANT1SCNRX

ant2SecondCellNumberRx

ANT2SCNRX

ant3SecondCellNumberRx

ANT3SCNRX

ant4SecondCellNumberRx

ANT4SCNRX

ant5SecondCellNumberRx

ANT5SCNRX

g With the SET BCOM command it is possible to "delete" the parameters setting the
value "NULL", not all together but first the wiring date and in a second command the
cell parameters (see Application Guidelines: of SET BCOM).
Validity Range
In commands CREATE BCOM, SET BCOM:
0 - 11

A50016-G5100-B333-04-7619

Id:0900d80580627a8f

585

BS-4x / 82 II / 240 / 241 / 240XL commands

<NULL>
In commands GET BCOM:
<ANY>
Default Value
In moc(s) BCOM:
None.
In moc(s) BCOM:
NULL
Contained in the following commands:
CREATE BCOM, GET BCOM, SET BCOM

ANT<x>WDRX
ant<x>WiringDataRx
The attribute specifies the carrier unit ports, which are connected to the Rx outputs of a
MDUX submodule. The maximum number of destinations is:

4 if MDUX only equipped

8 if MDUX and DUAMCO equipped

Note: <x> ... <0...5> so the names of the attributes read:


GUI: ant0WiringDataRx CLI: ANT0WDRX
ant1WiringDataRx

ANT1WDRX

ant2WiringDataRx

ANT2WDRX

ant3WiringDataRx

ANT3WDRX

ant4WiringDataRx

ANT4WDRX

ant5WiringDataRx

ANT5WDRX

The following values are possible for 'RX_wiring n':


H'0012FF00 CU0N (CU0 normal path)
H'00FF00 CU0D (CU0 diversity path)
H'0012FF01 CU1N (CU1 normal path)
H'0112FF01 CU1D (CU1 diversity path)
H'0012FF02 CU2N (CU2 normal path)
H'0112FF02 CU2D (CU2diversity path)
H'0012FF03 CU3N (CU3 normal path)
H'0112FF03 CU3D (CU3 diversity path)
H'0012FF04 CU4N (CU4 normal path)
H'0112FF04 CU4D (CU4 diversity path)
H'0012FF05 CU5N (CU5 normal path)
H'0112FF05 CU5D (CU5 diversity path)

586

Id:0900d80580627a8f

A50016-G5100-B333-04-7619

BS-4x / 82 II / 240 / 241 / 240XL commands

H'002AFF00 FCUMAIN0N (FCUMAIN0 normal path)


H'012AFF00 FCUMAIN0D (FCUMAIN0 diversity path)
H'022AFF00 FCUMAIN0N1 (FCUMAIN0 Rx C / N1 path)

g With the SET BCOM command it is possible to "delete" the parameters setting the
value "NULL", not all together but first the wiring date and in a second command the
cell parameters (see Application Guidelines: of SET BCOM).
Validity Range
1 to 8 items of
CU0N
CU0D
CU1N
CU1D
CU2N
CU2D
CU3N
CU3D
CU4N
CU4D
CU5N
CU5D
CU6N
CU6D
CU7N
CU7D
CU8N
CU8D
CU9N
CU9D
CU10N
CU10D
CU11N
CU11D
FCUMAIN0N
FCUMAIN0D
FCUMAIN0N1
FCUMAIN0D1

A50016-G5100-B333-04-7619

Id:0900d80580627a8f

587

BS-4x / 82 II / 240 / 241 / 240XL commands

FCUMAIN1N
FCUMAIN1D
FCUMAIN1N1
FCUMAIN1D1
FCUMAIN2N
FCUMAIN2D
FCUMAIN2N1
FCUMAIN2D1
FCUMAIN3N
FCUMAIN3D
FCUMAIN3N1
FCUMAIN3D1
FCUMAIN4N
FCUMAIN4D
FCUMAIN4N1
FCUMAIN4D1
FCUMAIN5N
FCUMAIN5D
FCUMAIN5N1
FCUMAIN5D1
FCUMAIN6N
FCUMAIN6D
FCUMAIN6N1
FCUMAIN6D1
FCUMAIN7N
FCUMAIN7D
FCUMAIN7N1
FCUMAIN7D1
FCUMAIN8N
FCUMAIN8D
FCUMAIN8N1
FCUMAIN8D1
FCUMAIN9N
FCUMAIN9D
FCUMAIN9N1
FCUMAIN9D1

588

Id:0900d80580627a8f

A50016-G5100-B333-04-7619

BS-4x / 82 II / 240 / 241 / 240XL commands

FCUMAIN10N
FCUMAIN10D
FCUMAIN10N1
FCUMAIN10D1
FCUMAIN11N
FCUMAIN11D
FCUMAIN11N1
FCUMAIN11D1
NULL
<NULL>
Default Value
None.
Contained in the following commands:
SETWIRINGRX BCOM

ANT<x>WDTX
ant<x>WiringDataTx
The attribute specifies the carrier unit ports which are either directly or via HYBRID6
connected to the TX input of an MDUX submodule. The maximum number of destinations is:

1 if MDUX without HYBRID6 equipped

2 if MDUX with HYBRID6 equipped

4 if MDUX with HYBRID6 and COAMCO equipped

Validity Range
1 to 4 items of
CU0
CU1
CU2
CU3
CU4
CU5
CU6
CU7
CU8
CU9
CU10

A50016-G5100-B333-04-7619

Id:0900d80580627a8f

589

BS-4x / 82 II / 240 / 241 / 240XL commands

CU11
FCUMAIN0TX0
FCUMAIN0TX1
FCUMAIN1TX0
FCUMAIN1TX1
FCUMAIN2TX0
FCUMAIN2TX1
FCUMAIN3TX0
FCUMAIN3TX1
FCUMAIN4TX0
FCUMAIN4TX1
FCUMAIN5TX0
FCUMAIN5TX1
FCUMAIN6TX0
FCUMAIN6TX1
FCUMAIN7TX0
FCUMAIN7TX1
FCUMAIN8TX0
FCUMAIN8TX1
FCUMAIN9TX0
FCUMAIN9TX1
FCUMAIN10TX0
FCUMAIN10TX1
FCUMAIN11TX0
FCUMAIN11TX1
NULL
<NULL>
Default Value
None.
Contained in the following commands:
SETWIRINGTX BCOM

ANTB
antennaBearing(degree)
Attribute data provided by the TMA.

590

Id:0900d80580627a8f

A50016-G5100-B333-04-7619

BS-4x / 82 II / 240 / 241 / 240XL commands

Validity Range
0 - 65535
<NULL>
Default Value
None.
Contained in the following commands:
GET TMA

ANTHOPHW
antennaHoppingHw
The attribute shows which antenna hardware is used by a TRX for
antenna hopping. The attribute doesn't show how often an antenna
hardware is used - i.e. the attribute doesn't reflect the actual antenna
hopping sequence. The attribute length is 0 for hh-ii=04-01 if no
antenna hopping is used.
Not BR8.0: In a switched beam cell, the attribute shows a list of
SDUSEC instances which are enabled in the cell and offer service to
the input TRXs (in this case 0 < n < 10).
type of HW = DUVSWR or SDUSEC
N <= 98 (decimal)

0 <= n < 24

Validity Range
0 to 23 items of
Pathname
Default Value
None.
Contained in the following commands:
GET TRX

ANTHOPMOD
antennaHoppingMode
This attribute specifies whether the BCCH transceiver has to be included in the hopping
sequence for Antenna Hopping or not. The attribute is only valid if the feature Antenna
Hopping is enabled (attribute enableAntennaHopping).
Validity Range
NOBCCHTRX
ALLTRX

A50016-G5100-B333-04-7619

Id:0900d80580627a8f

591

BS-4x / 82 II / 240 / 241 / 240XL commands

Default Value
NOBCCHTRX
Contained in the following commands:
GET BTS

ANTHOPP
antennaHoppingPeriod
This attribute specifies how many frames will be transmitted over each antenna before
the next antenna will be used to send the frames. The number of antenna changes
depends on the number of used antennas and service (4-4-5 used for EDGE).The attribute is only valid if the feature Antenna Hopping is enabled (attribute enableAntennaHopping).
Validity Range
ALL
SECOND
FOURTH
SEQ_445
Default Value
SECOND
Contained in the following commands:
GET BTS

ANTHOPST
antennaHoppingStatus
This attribute indicates the current status of Antenna Hopping. For a BTS only using
FICOM (FVSWRP) in transmit direction the attribute value is 'hopping off'. (FALSE =
hopping off)
Validity Range
TRUE
FALSE
Default Value
FALSE
Contained in the following commands:
GET BTS

ANTMN
antennaModelNumber

592

Id:0900d80580627a8f

A50016-G5100-B333-04-7619

BS-4x / 82 II / 240 / 241 / 240XL commands

Attribute data provided by the TMA.


Validity Range
0..15 characters string
Default Value
None.
Contained in the following commands:
GET TMA

ANTSN
antennaSerialNumber
Attribute data provided by the TMA.
Validity Range
0..17 characters string
Default Value
None.
Contained in the following commands:
GET TMA

ARFACCHACMDF
applyRFacchOnAnyCmdFrame
This attribute determines the LAPDm frame type on which R-FACCH (Repeated
FACCH) is allowed, if the latter has been enabled by the parameter enableRFACCH on
the respective codec type. The parameter is implemented as a bitmap consisting of 4
bits:
Bitmap Frame Type LAPDm Frame Type Description
0/1 I (ASSHOCMD) Only I-frames carrying ASS_CMD and HO_CMD. See note 1.
0/1 UI (PHSY_INFO) UI-frames carrying the PHSY_INFO. See note 1.
0/1 I (COMPLEMENTARY) I-frames excluding I (ASSHOCMD). See note 2.
0/1 UA UA response frames. See note 3.
The value '0' denotes R-FACCH is allowed while the value '1' denotes R-FACCH is not
allowed on the respective LAPDm frame type.

A50016-G5100-B333-04-7619

Id:0900d80580627a8f

593

BS-4x / 82 II / 240 / 241 / 240XL commands

g Notes:
1. R-FACCH shall not be used on command frames other than I-frames and UI-frames.
Both I-frames and UI-frames of LAPDm protocol are used for Information transfer
i.e. they contain payload of higher signaling layer. I-frames are transferred in
acknowledged mode whereas UI-frames are transferred in Unacknowledged mode.
2. Distinguishing between I-frames carrying ASS_CMD and HO_CMD: I(ASSHOCMD)
and the rest of I-frames: I(COMPLEMENTARY) is necessary due to problems anticipated with some types of legacy MS when receiving (COMPLEMENTARY) frames
in R-FACCH mode.
3. UA-frames are not allowed by the 3GPP-standard now, but a Change Request to
allow R-FACCH on UA-frames might be issued in the future. UA-frames of LAPDm
protocol are sent as Unnumbered Acknowledgement i.e. they are used to send
response to commands delivered previously in S-frames (Supervisory) frames.
Validity Range
TRUE
FALSE
Default Value
None.
Contained in the following commands:
GET BTS

ASCICIPH
enableCiphForASCI
The attribute enableCiphForASCI indicates whether ciphering for VGCS (Voice Group
Call Service) is
enabled or disabled. VGCS ciphering allows to offer a secured path on the radio interface for mobiles engaged in point to multipoint connections, as it was already possible
for the point to point calls.
Validity Range
TRUE
FALSE
Default Value
None.
Contained in the following commands:
GET BTS

ASEV
associatedSeverity

594

Id:0900d80580627a8f

A50016-G5100-B333-04-7619

BS-4x / 82 II / 240 / 241 / 240XL commands

The attribute allows the operator to define a specific severity for the failure event report
related to a envaBTSE instance (site input).
The severity of alarm database is used (DEFAULT_DB) as default value.
Validity Range
CRITICAL
MAJOR
MINOR
DEFAULT_DB
Default Value
DEFAULT_DB
Contained in the following commands:
CREATE ENVABTSE, GET ENVABTSE

AST
administrativeState
This attribute indicates whether the management services have permitted or prohibited
the use of the resource.
Validity Range
Locked
Unlocked
ShuttingDown
Default Value
Locked for functional objects
Unlocked for equipment objects
Contained in the following commands:
GET ACDCP, GET ACT, GET BATTERY, GET BCOM, GET BPORT, GET BTS,
GET BTSEP NOSWL, GET BTSM NOSWL, GET CESPW, GET CESTUNNEL, GET
CHAN, GET COBA, GET COBAETHINTF, GET COSA, GET CU, GET DIDCTMA,
GET DILNA, GET DUAMCO, GET DUDCTMA, GET DULNA, GET DUVSWR, GET
ENVABTSE, GET ETHCON, GET ETHPORT, GET F6DCTMA, GET F6LNA, GET
F6TNFP, GET F6VSWRP, GET FANP, GET FCUMAIN, GET FCUTR, GET FTNFP,
GET FVSWRP, GET LAPDLE, GET RACK, GET SYNCBTSE, GET TMA, GET TRX,
GET XCONNECT

ASTRING
associatedString

A50016-G5100-B333-04-7619

Id:0900d80580627a8f

595

BS-4x / 82 II / 240 / 241 / 240XL commands

This attribute allows the operator to define a specific text string for the failure event
report related to an environmental alarm. It will be put into the information element "additional text" of the failure event report. In case of hh=04 a specific string
(##ACDC_FAULT) can be used to indicate that the support of emergency configuration
in case of e.g. third party battery backup units is derived from the corresponding
envaBTSE instance.
The ASCII characters are not terminated by a NULL character.
Validity Range
0..26 characters string
Default Value
""
Contained in the following commands:
CREATE ENVABTSE, GET ENVABTSE

ASUBLKSAT
sAsubLinkSatellited
This attribute informs the BTSE SW about the presence of a satellite on the Asub interface.
Validity Range
terrestrialConnection
satelliteConnection
Default Value
terrestrialConnection
Contained in the following commands:
GET BTSM NOSWL

AVS
availabilityStatus
This attribute elaborates the Operational state and gives detailed information about the
actions that occur.
Validity Range
1 to 6 items of
InTest
Failed
PowerOff

596

Id:0900d80580627a8f

A50016-G5100-B333-04-7619

BS-4x / 82 II / 240 / 241 / 240XL commands

OffLine
OffDuty
Dependency
Degraded
NotInstalled
NULL
Default Value
Not Installed

for equipment objects

Off line

for TRX

NULL value

for BTS / CHAN / BTSM

Contained in the following commands:


GET ACDCP, GET ACT, GET BATTERY, GET BCOM, GET BPORT, GET BTS,
GET BTSEP NOSWL, GET BTSM NOSWL, GET CESPW, GET CESTUNNEL, GET
CHAN, GET COBA, GET COBAETHINTF, GET COSA, GET CU, GET DIDCTMA,
GET DILNA, GET DUAMCO, GET DUDCTMA, GET DULNA, GET DUVSWR, GET
ENVABTSE, GET ETHCON, GET ETHPORT, GET F6DCTMA, GET F6LNA, GET
F6TNFP, GET F6VSWRP, GET FANP, GET FCUMAIN, GET FCUTR, GET FTNFP,
GET FVSWRP, GET LAPDLE, GET RACK, GET SYNCBTSE, GET TMA, GET TRX,
GET XCONNECT

A50016-G5100-B333-04-7619

Id:0900d80580627a8f

597

BS-4x / 82 II / 240 / 241 / 240XL commands

b
BATTCAP
batteryCapacity(*5Ah)
This attribute contains the value of the actual capacity of the installed battery in units of
5 Ah. The attribute reflects the setting of the DIP switch on the ACDCP controller board.
The value 0 corresponds to no battery backup.
The value 255 corresponds to battery backup 1275 Ah.
Note: The value 'no battery backup (0 Ah)' for a created object 'BATTERY' means that
the operational state of the object will be "disabled". All other values result in the operational state "enabled".
Validity Range
0 - 255
<NULL>
Default Value
None.
Contained in the following commands:
GET BATTERY

BCCHFREQ
bcchFrequency
This attribute is used for the objects BTS and ADJC and ADJCUMTS.
It contains the absolute radio frequency channel number of the BCCH
channel. It is identical to the GSM attribute BCCH ARFCN.

598

cellAllocationNumber

Hex

Decimal

GSM900 "BB900"

0001 ... 007C

1 ... 124

GSM EXTENDED
"F2ONLY900"

0000 ... 007C

0 ... 124

03CF ... 03FF

975 ... 1023

GSM EXTENDED
REDUCED
"EXT900"

0000 ... 007C

0 ... 124

03CF ... 03FF

975 ... 1023

DCS 1800
"DCS1800"

0200 ... 0375

512 ... 885

PCS 1900

0200 ... 032A

512 ... 810

GSM-R

03BB ... 03CE

955 ... 974

Id:0900d8058051e6ce

A50016-G5100-B333-04-7619

BS-4x / 82 II / 240 / 241 / 240XL commands

GSM-DCS

0000 ... 007C

0 ... 124

03CF ... 03FF

975 ... 1023

0200 ... 0375

512 ... 885

GSM850

0080 ... 00FB

128 ... 251

GSM850-PCS

0080 ... 00FB

128 ... 251

0200 ... 032A

512 ... 810

0080 ... 00FB

128 ... 251

0200 ... 0375

512 ... 885

GSM850-DCS

Validity Range
0 - 1023
Default Value
None.
Contained in the following commands:
GET BTS

BCOMTYPE
bcomType
The attribute specifies the BCOM type. It is highly recommended to set this attribute to
the correct value in order to ensure software checks for a consistent wiring in terms of
the number of carrier units which can be wired to the BCOM.
It is the operator's responsibility to configure the correct value because the system
cannot check if the value fits to the equipped hardware.
Validity Range
SixToSix
TwelveToSix
SixToSixMDUX
TwelveToSixMDUX
TwelveToSixCOAMCO
NotSet
Default Value
NotSet
Contained in the following commands:
CREATE BCOM, GET BCOM, SET BCOM

A50016-G5100-B333-04-7619

Id:0900d8058051e6ce

599

BS-4x / 82 II / 240 / 241 / 240XL commands

BCPBL
boardCapability
This attribute returns the amount of configurable BPort interfaces on the related COBA
board.
Values are: 0\ twoAbisLines\ 1\ fourAbisLines\ 2\ ces
Validity Range
twoAbisLines
fourAbisLines
ces
<NULL>
Default Value
None.
Contained in the following commands:
GET COBA

BERT
bitErrorRateThreshold
This attribute defines thresholds allowed for a PCM30 or PCM24 line. The Bit Error Rate
is estimated using code violation counters. The specified thresholds influence the
setting of the corresponding status bits of the attribute 'lineStatusIndication'. When the
lower or upper threshold is reached, a failure event report is sent. Reaching the upper
threshold in a loop configuration triggers a direction switch.
Note: The values indicated as 'GET only' are values which were stored in a previous
release in the BTSE flash eprom when these values were still allowed in a SET
command.
Validity Range
In commands CREATE BPORT, SET BPORT:
lowerThreshold

E10_3
E10_4
...
E10_9

upperThreshold

E10_3
E10_4
E10_5

In commands GET BPORT:


lowerThreshold

E10_0
E10_1

600

Id:0900d8058051e6ce

A50016-G5100-B333-04-7619

BS-4x / 82 II / 240 / 241 / 240XL commands

...
E10_9
upperThreshold

E10_0
E10_1
...
E10_5

Default Value
In moc(s) BPORT:
None.
In moc(s) BPORT:
lowerThreshold

E10_5

upperThreshold

E10_3

Contained in the following commands:


CREATE BPORT, GET BPORT, SET BPORT

BMWD<x>
beamWidth<x>(degree)
Attribute data provided by the TMA.
Validity Range
0 - 65535
<NULL>
Default Value
None.
Contained in the following commands:
GET TMA

BND<x>
band<x>
Attribute data provided by the TMA.
Validity Range
operating_band_I
operating_band_II
operating_band_III
operating_band_IV
operating_band_V

A50016-G5100-B333-04-7619

Id:0900d8058051e6ce

601

BS-4x / 82 II / 240 / 241 / 240XL commands

operating_band_VI
operating_band_VII
operating_band_VIII
operating_band_IX
<NULL>
Default Value
None.
Contained in the following commands:
GET TMA

BSIC
bsIdentityCode
This attribute contains the Base Transceiver Station Identity Code (BSIC), which is
transmitted on the SCH and used for identifying a BTS. The BSIC consists of the
Network Colour Code (NCC) and the Base Station Colour Code (BCC).
Validity Range
BCC

0-7

NCC

0-7

Default Value
None.
Contained in the following commands:
GET BTS

BSWVER
bootSoftwareVersion
This attribute defines the firmware item code number. It can be read from the Boot
EPROM of each processor module. The values for this attribute are identical with the
SW image format (file ID and version) used in the swLoad-header-file. (exception: two
bootSoftwareVersions for the TPU) or 'Not Existing' for Modules that are not equipped
with a processor.
Each single field of the validity range has the following meaning.
bootSWfield 'BTBrrrhh.SWI', where:
rr BCX for COBA
BIX for CU
LMX for LMU (not used)
hh identical with the corresponding part of the bootSWversion
bootSwVersion 'cn-hh-vv-ii-ss-pp_yy-mm-dd, where:

602

Id:0900d8058051e6ce

A50016-G5100-B333-04-7619

BS-4x / 82 II / 240 / 241 / 240XL commands

cn Version part (network operator code)


hh Version part (HW/SW compatibility code)
vv Version part (feature package code)
ii Version part (sub-feature package code)
ss Version part (actual state)
pp Patch version (usually 00)
yy-mm-dd Production date (optional)
Validity Range
39..39 characters string
Default Value
None.
Contained in the following commands:
GET COBA, GET CU, GET FCUMAIN,

BTSID
baseStationId
Attribute data provided by the TMA.
Validity Range
0..32 characters string
Default Value
None.
Contained in the following commands:
GET TMA

BTSISHOP
btsIsHopping
This attribute indicates whether the BTS uses frequency hopping or not.
FALSE = Indicates that none of the channels in the BTS hops from the O&M point of
view; from radio signalling point of view this can mean either that there is really no
hopping at all or that there is hopping over a single frequency.
TRUE = Means that hopping is specified on a per channel basis.
Validity Range
TRUE
FALSE
Default Value
FALSE

A50016-G5100-B333-04-7619

Id:0900d8058051e6ce

603

BS-4x / 82 II / 240 / 241 / 240XL commands

Contained in the following commands:


GET BTS

BURNOFFS
burstNumberOffset
This attribute allows to adjust the burst number offset for a cell. Equal burst number
offsets result in synchronized TDMA frames.
This attribute is only meaningful if and the attribute enableInterSiteSync is set to 'TRUE'.
Validity Range
0-7
Default Value
0
Contained in the following commands:
GET BTS

604

Id:0900d8058051e6ce

A50016-G5100-B333-04-7619

BS-4x / 82 II / 240 / 241 / 240XL commands

c
CCPBL
carrierCapability
This attribute describes the call processing capabilities of the CU and FCUTR.
- In case of CU the attribute value is derived from the ESN/PID value of the CU.
- In case of FCUTR the attribute value depends on the istance number and the fcuMode
of the corrisponding FCUMAIN object.
The attribute is read-only from the Abis/LMT point of view (GET CU/ GET FCUTR). After
creation in advance of a CU/FCUTR object the attribute has the value "unknown" in case
of hh-ii =04-01.
The BTSE SW maps the values of the attribute carrierCapability to the values of the attribute trxCapability
In case of FCUTR object, the validity range is:
- unknown
- edge
- edgeFourRXdiv
- in case of FCUTR both the values 'edge' and 'edgeFourRXdiv' are mapped to 'trxCapability=edge'.

Validity Range
In commands GET CU:
unknown
gsm
edge
In commands GET FCUTR:
unknown
edge
edgeFourRxDiv
Default Value
None.
Contained in the following commands:
GET CU, GET FCUTR

CELLNO
cellNumber

A50016-G5100-B333-04-7619

Id:0900d80580592b9a

605

BS-4x / 82 II / 240 / 241 / 240XL commands

This attribute indicates the cell number to which a HW object for the antenna combining
(DILNA, DULNA, DUVSWR, FTNFP, FVSWRP, SDUSEC) is related to. It allows to have
more than one antenna combining object in a cell.
Validity Range
0 - 11
Default Value
None.
Contained in the following commands:
CREATE DILNA, CREATE DULNA, CREATE DUVSWR, CREATE F6LNA, CREATE
F6VSWRP, CREATE FTNFP, CREATE FVSWRP, GET DILNA, GET DULNA, GET
DUVSWR, GET F6LNA, GET F6VSWRP, GET FTNFP, GET FVSWRP,

CELLTYPE
cellType
This attribute indicates the type of cell. It is used by BTSE for compatibility checks of the
HW of a cell.
Validity Range
STDCELL
EXTCELL
DBSTDCELL
Default Value
None.
Contained in the following commands:
GET BTS

CHIDT
changeOnIDT
This attribute indicates a potential change of the IDTwF file. Whenever the IDFwF file
was uploaded by the BSC the value is set to 'no change on IDT'. If a change of objects
and attributes with relation to the IDT file occurs the value is set to 'IDT was changed'.
If a local download of IDT data is done the value must be set manually to 'IDT was
changed'.
Validity Range
noChangeOnIDT
IDTWasChanged
Default Value
IDTWasChanged

606

Id:0900d80580592b9a

A50016-G5100-B333-04-7619

BS-4x / 82 II / 240 / 241 / 240XL commands

Contained in the following commands:


GET BTSEP NOSWL, SET BTSEP

CHTYPE
channelCombination
This attribute defines the logical channel combination mapped onto
the physical channel (timeslot).Changing or setting this attribute
means a temporary loss of service for the whole TRX.

00 TCHFULL:

TCH/F + FACCH/F + SACCH/TF

03 SDCCH:

SDCCH/8 + SACCH/C8

Note 3

04 MAINBCCH:

FCCH + SCH + BCCH + CCCH

Note 4

05 MBCCHC:

FCCH + SCH + BCCH + CCCH


+SDCCH/4 + SACCH/C4

Note 4

06 CCCH:

BCCH + CCCH

Note 5

07 SCBCH:

SDCCH/8 + SACCH/C8 + CBCH

Note
1/6

08 BCBCH:

FCCH + SCH + BCCH + CCCH +


SDCCH/4 + SACCH/4 + CBCH

Note
1/7

09
TCHF_HLF:

TCH/H(0,1) + FACCH/H(0,1) +
SACCH/TH (0,1) or TCH/F + FACCH/F +
SACCH/TF

Note 2

0A TCHSD:

TCH/H(0,1) + FACCH/H(0,1) +
SACCH/TH (0,1) or TCH/F + FACCH/F +
SACCH/TF or SDCCH/8 + SACCH/C8

Note
2/3

Note 1:

These two channel combinations are created by


replacing the logical channel SDCCH number 2 with
the CBCH channel.

Note 2:

The actual mode is decided on a per call basis.

Note 3:

Not allowed for CHAN #0 of BCCH-TRX. Only


allowed up to 3 times together with SDCCH/4 on
BCCH-TRX. With no SDCCH/4 on the BCCH
carrier up to four SDCCH/8 are allowed on the
BCCH carrier. (For hh=04 this restriction may be
dropped in a later release).

Note 4:

Allowed only for CHAN #0 of BCCH-TRX.

Note 5:

Allowed only for CHAN #2, #4, #6 of BCCH-TRX.


Not allowed together with SDCCH/4.

Note 6:

Allowed only for CHAN #0, #1, #2, #3. Not allowed
for CHAN #0 of BCCH-TRX. Only one CBCH is
allowed per cell.

A50016-G5100-B333-04-7619

Id:0900d80580592b9a

607

BS-4x / 82 II / 240 / 241 / 240XL commands

Note 7:

Only one CBCH is allowed per cell.

Note 8:

BSC checks guarantee that the first SDCCH/8 is


created on the BCCH TRX and that a CBCH is
allowed only on the BCCH TRX.

where:
TCH =

Traffic Channel

FACCH =

Fast Associated Control Channel

SACCH =

Slow Associated Control Channel

/H =

Half Rate

/F =

Full Rate

FCCH =

Frequency Correction Channel

SCH =

Synchronization Channel

BCCH =

Broadcast Control Channel

CCCH =

Common Control Channel (CCCH = PCH + RACH


+ AGCH)

PCH =

Paging Channel

RACH =

Random Access Channel

AGCH =

Access Grant Channel

CBCH =

Cell Broadcast Channel

The SDCCH combinations for the BCCH-TRX can be summarized as


follows:
1 MAIN BCCH + 4 SDCCH/8
1 MAIN BCCH COMBINED (SDCCH/4) + 3 SDCCH/8
1 MAIN BCCH + SCBCH (SDCCH/7) + 3 SDCCH/8
1 BCBCH (SDCCH/3) + 3 SDCCH/8
Validity Range
TCHFULL
SDCCH
MAINBCCH
MBCCHC
CCCH
SCBCH
BCBCH
TCHF_HLF
TCHSD
Default Value
None.

608

Id:0900d80580592b9a

A50016-G5100-B333-04-7619

BS-4x / 82 II / 240 / 241 / 240XL commands

Contained in the following commands:


GET CHAN

CLKACC
clockAccuracy
This attribute indicates the accuracy of the clock.
Validity Range
high
medium
low
phase
Default Value
None.
Contained in the following commands:
GET SYNCBTSE

COMBMD
combMode
This attribute describes the combining mode of ACOM, DUVSWR (DUAMCO_VSRW),
DULNA (DUAMCO_LNA) and DILNA(DIAMCO_LNA) . The "n:m" values listed below
have the meaning "n RF inputs are combined to m RF output(s) by the ACOM,
DUAMCO/FDUAMCO or DIAMCO board ". The values are not checked by BTSE applications, the values are only stored for the convenience of the operator.
Validity Range
In commands CREATE DILNA, GET DILNA:
EightToTwo
In commands CREATE DULNA, CREATE DUVSWR, GET DULNA, GET DUVSWR:
OneToOne
TwoToOne
TwoToTwo
FourToTwo
EightToTwo
TwoToOneCOAMCO8
Default Value
In moc(s) DULNA, DUVSWR:
None.
In moc(s) DILNA:

A50016-G5100-B333-04-7619

Id:0900d80580592b9a

609

BS-4x / 82 II / 240 / 241 / 240XL commands

EightToTwo
Contained in the following commands:
CREATE DILNA, CREATE DULNA, CREATE DUVSWR, GET DILNA, GET DULNA,
GET DUVSWR

CUCONF
carrierUnitConfiguration
This attributes describes, if in a cell a homogeneous configuration of
carrier units is present (default value) or if one of the defined exceptions is configured.
The following configurations are defined:
-

CU_FlexCU_BS82II: This value has to be set if the cell is


served by a BS82II and has an inhomogeneous carrier unit
configuration with FlexCU and CU/ECU/GCU.

CU_ECU_DCSPCS: This value has to be set if the cell has an


inhomogeneous carrier unit configuration with old 1800/1900
MHz CUs (45.3 dBm output power) and ECU V2/3/3a of the
same frequency band. This value replaces the former setting
of the CU attribute maxGMSKOutputPower to dBm46_3.

homogeneous: This value has to be set if the carrier unit configuration is homogeneous or shall be considered as homogeneous. All carrier units use the maximum output power, which
is provided by the hardware. No adaptation of the output
power is performed. This implies, that output power differences greater than 2 dB will be accepted. This setting corresponds to the current system behaviour.

Validity Range
homogenous
CU_FlexCU_BS82II
CU_ECU_DCSPCS
Default Value
homogeneous
Contained in the following commands:
GET BTS

CUWIRING
cuWiring
The attribute describes the Tx and Rx wiring of the CU to the combining equipment. The
attribute identifier cannot be present in the listOfRequiredAttributes together attribute

610

Id:0900d80580592b9a

A50016-G5100-B333-04-7619

BS-4x / 82 II / 240 / 241 / 240XL commands

identifiers; the attribute is not sent by the BTSE if a Get CU is done without the information element listOfRequiredAttributes.
Below are indicated some details about the validity range.
choice tag:
1 0-3 optional subfields of fixed length follow (length=4-16)
txWiringPresence: (present only if choice tag is 1)
1 the next 4 bytes contain object class & instance of the object wired to the TX output
0 object class & instance don't follow
rxNWiringPresence: (present only if choice tag is 1, Octet position is variable)
1 the next 4 bytes contain object class & instance of the object wired to the RX output N
0 object class & instance don't follow
rxDWiringPresence: (present only if choice tag is 1, Octet position is variable)
1 the next 4 bytes contain object class & instance of the object wired to the RX output D
0 object class & instance don't follow

Validity Range
<ANY>
Default Value
None.
Contained in the following commands:
GET CU WIRING

A50016-G5100-B333-04-7619

Id:0900d80580592b9a

611

BS-4x / 82 II / 240 / 241 / 240XL commands

d
DESTDIR
destinationDir
Destination directory
This attribute specifies the directory on the LMT hard disk where the
BTSE alarm buffer sw will be copied (UPLBTSLOG).
This attribute specifies the directory on the LMT hard disk where the
IDT file will be copied (UPLLIDF).
Validity Range
1..80 characters string
Default Value
None.
Contained in the following commands:
UPLBTSLOG SOFTWARE-MANAGEMENT, UPLLIDF REMINV

DLTESTFREQ
dlTestFrequency
This attribute defines the transmit frequency (ARFCN value) if the downlink interference
analysis mode is enabled.
Validity Range
<ANY>
Default Value
None.
Contained in the following commands:
GET TRX

DMACFHSYID
dmaCFHSyId
This attribute is used for distinguishing DMA-enabled TRXs, which are operating on different frequency bands or at different subbands in the same cell.
Validity Range
usedOnCFHSY0
usedOnCFHSY1

612

Id:0900d8058024e34f

A50016-G5100-B333-04-7619

BS-4x / 82 II / 240 / 241 / 240XL commands

notUsed
Default Value
DMA not used on TRX
Contained in the following commands:
GET TRX

DMCFWID
duamcoFwId
This attribute provides information of the file ID and the FW version that is active on a
MFDUAMCO board.
Validity Range
39..39 characters string
Default Value
None.
Contained in the following commands:
GET DUAMCO

DTMHOMTIMER
hoDTMTimer(SACCH_multiframe_480/470ms)
This attribute determines whether handover due to DTM(Dual Transfer Mode) power
budget is enabled.
This attribute is only relevant if inter-cell handover is enabled in the cell (see attribute
enableInterCellHO).
DTM Power budget handover means: handover to another cell if this cell offers a higher
transmission level. No matter if the power level of the actual cell is above the minimum
or not.

Validity Range
1 - 21
Default Value
None.
Contained in the following commands:
GET BTS

DYNTRACGRAN
dynTraceGranularity

A50016-G5100-B333-04-7619

Id:0900d8058024e34f

613

BS-4x / 82 II / 240 / 241 / 240XL commands

dynTraceGranularity is an attribute of the BTSM and specifies the granularity (multiples


of SACCH reporting period) in which the TRACE MEASUREMENT RESULT messages
are transmitted on the Abis interface in case the trace is activated. A value of N means
that every N-th message is transmitted. The trace is activated per channel via the
acknowledged message START TRACE. The trace is stopped via the acknowledged
message STOP TRACE on the radio signalling link; it is stopped also implicitly at a
release of the channel.
The validity range is indicated in number of "SACCH multiframes"
Validity Range
1 - 254
Default Value
1
Contained in the following commands:
GET BTSM NOSWL

614

Id:0900d8058024e34f

A50016-G5100-B333-04-7619

BS-4x / 82 II / 240 / 241 / 240XL commands

e
EAC
enableAc
This attribute determines, whether Admission Control evaluation must be performed. A
change of the attribute becomes effective in the next AC period.
(TRUE = AC evaluation enabled)
Validity Range
TRUE
FALSE
Default Value
FALSE (AC evaluation disabled)
Contained in the following commands:
GET BTS

EANTHOP
enableAntennaHopping
This attribute indicates whether Antenna Hopping is enabled or disabled for BTS. All
TRX which are not connected to FICOM will hop.
A change of the attribute becomes effective with starting time algorithm handled internally by the BTSE.
TRUE = enabled
Validity Range
TRUE
FALSE
Default Value
FALSE (disabled)
Contained in the following commands:
GET BTS

EAUTONEG
enableAutoNegotiation
The attribute indicates whether the Ethernet auto negotiation for speed, duplex mode
and optionally flow control is enabled for the instance of an Ethernet port.
If auto negotiation is disabled the speed will be set to 100M and duplex mode will be
enabled. Also in case when this attribute is set to TRUE there will be propagated only

A50016-G5100-B333-04-7619

Id:0900d8058024e358

615

BS-4x / 82 II / 240 / 241 / 240XL commands

100M and duplex mode. If the peer Ethernet device cannot provide 100M Duplex mode,
then the link remains down. Only FlowControl is really negotiated according to the
setting of the attribute "enableFlowControl".
AutoNegotiation is only relevant for electrical Ethernet interfaces.
Validity Range
TRUE
FALSE
Default Value
TRUE
Contained in the following commands:
CREATE ETHPORT, GET ETHPORT, SET ETHPORT

EAUTOREC
enableAutoRecovery
This attribute indicates whether an automatic recovery is enabled or disabled. Prerequisites for an automatic recovery in case the feature is enabled are:
- HW-Reset cause is "Power-On"
- The board is disabled.failed.unlocked
Validity Range
disabled
enabled
Default Value
disabled
Contained in the following commands:
GET BTSEP NOSWL, SET BTSEP

EEOTD
enableEOTD
This attribute indicates if the Location Services (LCS) positioning method 'Enhanced
Observed Time difference' (EOTD) is being used.
(TRUE = enabled)
Validity Range
TRUE
FALSE

616

Id:0900d8058024e358

A50016-G5100-B333-04-7619

BS-4x / 82 II / 240 / 241 / 240XL commands

Default Value
FALSE (disabled)
Contained in the following commands:
GET BTS

EEXCDIST
enableExcessiveDistance
This attribute indicates whether the sending of call release is enabled/disabled when the
distance between Mobile Station and BTS exceeds the excessive distance.
TRUE = enabled
Validity Range
FALSE
TRUE
Default Value
TRUE (enabled)
Contained in the following commands:
GET BTS

EFCUSUP
enableFcuSupport
For a COB4P12, 'TRUE' is the only possible value and will be
assigned by the BTSE-software in case no value is provided by the
operator; the attribute value 'TRUE' cannot be changed by the operator.
For COBA2P8 both values are possible.
- 'FALSE' will be assigned by the BTSE-software in case no value is
provided by the operator. In this case the BTSE handles up to 24 CU
boards (distributed to rack 0-2). If enableFcuSupport is set to
'FALSE', the creation of the objects FCUMAIN / FCUTR is possible
but any created objects FCUMAIN / FCUTR will remain in state: operationalState 'DISABLED', availabilityStatus 'Not Installed'.
- 'TRUE' means that the BTSE can handle only up to 12 boards.
Within these 12 boards (allowed only in base rack in case of
BTS240XL, respectively allowed only in base rack and the first 4
instances of 1st extension-rack in case of BTS240 distributed to rack
0-2) any mix of CU boards and FlexCU boards (modeled as
FCUMAIN and FCUTR objects) is possible.
--> The creation of any boards (CU or FlexCU) will be answered with
a NACK by the BTSE, if:

A50016-G5100-B333-04-7619

Id:0900d8058024e358

617

BS-4x / 82 II / 240 / 241 / 240XL commands

typeofBTSE is BS240XL and the board to be created is in the


extension rack

typeofBTSE is BS240 and the board to be created is in the 1st


extension rack and would have an instance number greater 3,
or is in the 2nd extension rack.

A change of the attribute value is possible only on a COBA2P8 and


causes a reset of the BTSE. In LMTphase 3 a change of the attribute
value is allowed only if the administrativeState of BTSM is 'Locked'.
--> The BTSE SW will answer with a NACK if the operator tries to set
the attribute to 'TRUE' if:
-

typeofBTSE is BS240XL and a board (FlexCU or CU) is


created in an extension rack

typeofBTSE is BS240 and a FlexCU or CU with an instance


greater than 3 is created in 1st extension rack or any instance
is created in 2nd extension rack.

The value FALSE in the validity range means:


support of FLEXCU disabled
The value TRUE in the validity range means:
support of FLEXCU enabled
Validity Range
TRUE
FALSE
Default Value
None.
Contained in the following commands:
CREATE COBA, GET COBA, SET COBA

EFLWCTRL
enableFlowControl
The attribute enables the Ethernet flow control. Flow control requires full duplex operation. Received Ethernet PAUSE frames are ignored if set to false.
The following attribute is relevant: enableAutonegotiation
Validity Range
TRUE
FALSE

618

Id:0900d8058024e358

A50016-G5100-B333-04-7619

BS-4x / 82 II / 240 / 241 / 240XL commands

Default Value
FALSE
Contained in the following commands:
CREATE ETHPORT, GET ETHPORT, SET ETHPORT

EINTSITSYN
enableInterSiteSync
The attribute enableInterSiteSync allows to disable or enable the inter site synchronization.
If intersite synchronisation is enabled, the BTS attributes burstNumberOffset and frameNumberOffset become effective. As a result different transceivers of the same BTSE
may have asynchronous frame and burst numbers.
TRUE = enabled
Validity Range
TRUE
FALSE
Default Value
FALSE (disabled)
Contained in the following commands:
GET BTSM NOSWL

EMT1
emergencyTimer1(min)
This attribute specifies after which time (minutes) the BTSE will be switched to an emergency configuration if a "battery backup operation" (due to "mains breakdown") occurs.
The switch includes the power-down of TRX related equipment.
BS241: emerg. timer starts if first ACDC fails.
(step size 1 minute)
Validity Range
0 - 1400
Default Value
10 minutes
Contained in the following commands:
GET BTSM NOSWL

A50016-G5100-B333-04-7619

Id:0900d8058024e358

619

BS-4x / 82 II / 240 / 241 / 240XL commands

EMT2
emergencyTimer2(min)
This attribute specifies after which time (minutes) the BTSE will be switched to a zero
carrier configuration if a switch to emergency configuration has been performed due to
a "battery backup operation". The switch includes the power-down of TRX related equipment. The value 0 means the emergencyTimer2 is not valid, i.e. the BTSE will not switch
to a zero carrier configuration. For other values the zero carrier configuration will be
reached after the sum of the times specified in emergencyTimer1 and
emergencyTimer2.
Validity Range
0 - 1400
Default Value
0 minutes
Contained in the following commands:
GET BTSM NOSWL

ENTRIES
entries
Number of entries
This attribute is used to indicate the number of the entries to be
uploaded.
Validity Range
Number of the requested Entries <1-65534>
Getting all Entries stored in the buffer 65535
For the upload of MIB_DATA_HW_STATES only the value 65535 is used.
For the upload of INVENTORY_DATA_TABLE, MIT and SCA the attribute has no
meaning.
Default Value
None.
Contained in the following commands:
UPLBTSLOG SOFTWARE-MANAGEMENT

EQUPOS
equipmentPosition
The attribute contains the room / row and rack number as 6 ASCII characters not terminated by a NUL character. The attribute should be set by the operator before a upload
of the IDT is performed.

620

Id:0900d8058024e358

A50016-G5100-B333-04-7619

BS-4x / 82 II / 240 / 241 / 240XL commands

Validity Range
6..6 characters string
Default Value
"010101"
Contained in the following commands:
GET BTSEP NOSWL, SET BTSEP

ERFACCHALPDMF
enableRFacchOnAnyLapdmFrame
This attribute determines whether the feature DL Repeated FACCH is enabled on a per
cell basis for different codec types and only for those MS that have signaled their
Repeated FACCH Capability as 1. To enable R-FACCH on any LAPDm command and
response frame for a certain codec in the cell the name of that codec shall be entered
in a list.
See Appendix for the values.
Validity Range
NOT_SET
AFS
AHS
AFS_AHS
EFS
AFS_EFS
AHS_EFS
AFS_AHS_EFS
FS
AFS_FS
AHS_FS
AFS_AHS_FS
EFS_FS
AFS_EFS_FS
AHS_EFS_FS
AFS_AHS_EFS_FS
HS
AFS_HS
AHS_HS
AFS_AHS_HS

A50016-G5100-B333-04-7619

Id:0900d8058024e358

621

BS-4x / 82 II / 240 / 241 / 240XL commands

EFS_HS
AFS_EFS_HS
AHS_EFS_HS
AFS_AHS_EFS_HS
FS_HS
AFS_FS_HS
AHS_FS_HS
AFS_AHS_FS_HS
EFS_FS_HS
AFS_EFS_FS_HS
AHS_EFS_FS_HS
AFS_AHS_EFS_FS_HS
WFS
AFS_WFS
AHS_WFS
AFS_AHS_WFS
EFS_WFS
AFS_EFS_WFS
AHS_EFS_WFS
AFS_AHS_EFS_WFS
FS_WFS
AFS_FS_WFS
AHS_FS_WFS
AFS_AHS_FS_WFS
EFS_FS_WFS
AFS_EFS_FS_WFS
AHS_EFS_FS_WFS
AFS_AHS_EFS_FS_WFS
HS_WFS
AFS_HS_WFS
AHS_HS_WFS
AFS_AHS_HS_WFS
EFS_HS_WFS
AFS_EFS_HS_WFS
AHS_EFS_HS_WFS
AFS_AHS_EFS_HS_WFS

622

Id:0900d8058024e358

A50016-G5100-B333-04-7619

BS-4x / 82 II / 240 / 241 / 240XL commands

FS_HS_WFS
AFS_FS_HS_WFS
AHS_FS_HS_WFS
AFS_AHS_FS_HS_WFS
EFS_FS_HS_WFS
AFS_EFS_FS_HS_WFS
AHS_EFS_FS_HS_WFS
AFS_AHS_EFS_FS_HS_
WFS
Default Value
None.
Contained in the following commands:
GET BTS

ERFACCHCMDF
enableRFacchOnCmdFrames
This attribute determines whether the feature DL Repeated FACCH is enabled on a per
cell basis for different codec types and only for those MS that have signaled their
Repeated FACCH Capability as 1. To enable R-FACCH on any LAPDm command and
response frame for a certain codec in the cell the name of that codec shall be entered
in a list.
See Appendix for the values.
Validity Range
NOT_SET
AFS
AHS
AFS_AHS
EFS
AFS_EFS
AHS_EFS
AFS_AHS_EFS
FS
AFS_FS
AHS_FS
AFS_AHS_FS
EFS_FS
AFS_EFS_FS

A50016-G5100-B333-04-7619

Id:0900d8058024e358

623

BS-4x / 82 II / 240 / 241 / 240XL commands

AHS_EFS_FS
AFS_AHS_EFS_FS
HS
AFS_HS
AHS_HS
AFS_AHS_HS
EFS_HS
AFS_EFS_HS
AHS_EFS_HS
AFS_AHS_EFS_HS
FS_HS
AFS_FS_HS
AHS_FS_HS
AFS_AHS_FS_HS
EFS_FS_HS
AFS_EFS_FS_HS
AHS_EFS_FS_HS
AFS_AHS_EFS_FS_HS
WFS
AFS_WFS
AHS_WFS
AFS_AHS_WFS
EFS_WFS
AFS_EFS_WFS
AHS_EFS_WFS
AFS_AHS_EFS_WFS
FS_WFS
AFS_FS_WFS
AHS_FS_WFS
AFS_AHS_FS_WFS
EFS_FS_WFS
AFS_EFS_FS_WFS
AHS_EFS_FS_WFS
AFS_AHS_EFS_FS_WFS
HS_WFS
AFS_HS_WFS

624

Id:0900d8058024e358

A50016-G5100-B333-04-7619

BS-4x / 82 II / 240 / 241 / 240XL commands

AHS_HS_WFS
AFS_AHS_HS_WFS
EFS_HS_WFS
AFS_EFS_HS_WFS
AHS_EFS_HS_WFS
AFS_AHS_EFS_HS_WFS
FS_HS_WFS
AFS_FS_HS_WFS
AHS_FS_HS_WFS
AFS_AHS_FS_HS_WFS
EFS_FS_HS_WFS
AFS_EFS_FS_HS_WFS
AHS_EFS_FS_HS_WFS
AFS_AHS_EFS_FS_HS_
WFS
Default Value
None.
Contained in the following commands:
GET BTS

ERSACCHDL
enableRSacchDL
The attribute is implemented as a list of values representing combinations of signaling
and allowed codec types and/or signaling. This list is present in Appendix.
For the binary representation 0 means that R-SACCH in DL on a per cell basis is not
applied for specified speech codec type and /or signaling. Value 1 means that R-SACCH
in DL is applied for specified speech codec type and/or signaling.
Value 0x00 has specific meaning and should be read as R-SACCH in DL is not applied
for any speech codec type.
When enabling R-SACCH feature on BTS, where only old CUs are created, SET is
acked but ignored locally.
Validity Range
NOT_SET
AFS
AHS
AFS_AHS
EFS

A50016-G5100-B333-04-7619

Id:0900d8058024e358

625

BS-4x / 82 II / 240 / 241 / 240XL commands

AFS_EFS
AHS_EFS
AFS_AHS_EFS
FS
AFS_FS
AHS_FS
AFS_AHS_FS
EFS_FS
AFS_EFS_FS
AHS_EFS_FS
AFS_AHS_EFS_FS
HS
AFS_HS
AHS_HS
AFS_AHS_HS
EFS_HS
AFS_EFS_HS
AHS_EFS_HS
AFS_AHS_EFS_HS
FS_HS
AFS_FS_HS
AHS_FS_HS
AFS_AHS_FS_HS
EFS_FS_HS
AFS_EFS_FS_HS
AHS_EFS_FS_HS
AFS_AHS_EFS_FS_HS
WFS
AFS_WFS
AHS_WFS
AFS_AHS_WFS
EFS_WFS
AFS_EFS_WFS
AHS_EFS_WFS
AFS_AHS_EFS_WFS
FS_WFS

626

Id:0900d8058024e358

A50016-G5100-B333-04-7619

BS-4x / 82 II / 240 / 241 / 240XL commands

AFS_FS_WFS
AHS_FS_WFS
AFS_AHS_FS_WFS
EFS_FS_WFS
AFS_EFS_FS_WFS
AHS_EFS_FS_WFS
AFS_AHS_EFS_FS_WFS
HS_WFS
AFS_HS_WFS
AHS_HS_WFS
AFS_AHS_HS_WFS
EFS_HS_WFS
AFS_EFS_HS_WFS
AHS_EFS_HS_WFS
AFS_AHS_EFS_HS_WFS
FS_HS_WFS
AFS_FS_HS_WFS
AHS_FS_HS_WFS
AFS_AHS_FS_HS_WFS
EFS_FS_HS_WFS
AFS_EFS_FS_HS_WFS
AHS_EFS_FS_HS_WFS
AFS_AHS_EFS_FS_HS_
WFS
SIGNALING
AFS_SIGNALING
AHS_SIGNALING
AFS_AHS_SIGNALING
EFS_SIGNALING
AFS_EFS_SIGNALING
AHS_EFS_SIGNALING
AFS_AHS_EFS_SIGNALIN
G
FS_SIGNALING
AFS_FS_SIGNALING
AHS_FS_SIGNALING

A50016-G5100-B333-04-7619

Id:0900d8058024e358

627

BS-4x / 82 II / 240 / 241 / 240XL commands

AFS_AHS_FS_SIGNALIN
G
EFS_FS_SIGNALING
AFS_EFS_FS_SIGNALING
AHS_EFS_FS_SIGNALIN
G
AFS_AHS_EFS_FS_SIGN
ALING
HS_SIGNALING
AFS_HS_SIGNALING
AHS_HS_SIGNALING
AFS_AHS_HS_SIGNALIN
G
EFS_HS_SIGNALING
AFS_EFS_HS_SIGNALIN
G
AHS_EFS_HS_SIGNALIN
G
AFS_AHS_EFS_HS_SIGN
ALING
FS_HS_SIGNALING
AFS_FS_HS_SIGNALING
AHS_FS_HS_SIGNALING
AFS_AHS_FS_HS_SIGNA
LING
EFS_FS_HS_SIGNALING
AFS_EFS_FS_HS_SIGNA
LING
AHS_EFS_FS_HS_SIGNA
LING
AFS_AHS_EFS_FS_HS_S
IGNALING
WFS_SIGNALING
AFS_WFS_SIGNALING
AHS_WFS_SIGNALING
AFS_AHS_WFS_SIGNALI
NG
EFS_WFS_SIGNALING
AFS_EFS_WFS_SIGNALI
NG

628

Id:0900d8058024e358

A50016-G5100-B333-04-7619

BS-4x / 82 II / 240 / 241 / 240XL commands

AHS_EFS_WFS_SIGNALI
NG
AFS_AHS_EFS_WFS_SIG
NALING
FS_WFS_SIGNALING
AFS_FS_WFS_SIGNALIN
G
AHS_FS_WFS_SIGNALIN
G
AFS_AHS_FS_WFS_SIGN
ALING
EFS_FS_WFS_SIGNALIN
G
AFS_EFS_FS_WFS_SIGN
ALING
AHS_EFS_FS_WFS_SIGN
ALING
AFS_AHS_EFS_FS_WFS_
SIGNALING
HS_WFS_SIGNALING
AFS_HS_WFS_SIGNALIN
G
AHS_HS_WFS_SIGNALIN
G
AFS_AHS_HS_WFS_SIGN
ALING
EFS_HS_WFS_SIGNALIN
G
AFS_EFS_HS_WFS_SIGN
ALING
AHS_EFS_HS_WFS_SIGN
ALING
AFS_AHS_EFS_HS_WFS
_SIGNALING
FS_HS_WFS_SIGNALING
AFS_FS_HS_WFS_SIGNA
LING
AHS_FS_HS_WFS_SIGNA
LING
AFS_AHS_FS_HS_WFS_
SIGNALING

A50016-G5100-B333-04-7619

Id:0900d8058024e358

629

BS-4x / 82 II / 240 / 241 / 240XL commands

EFS_FS_HS_WFS_SIGNA
LING
AFS_EFS_FS_HS_WFS_S
IGNALING
AHS_EFS_FS_HS_WFS_
SIGNALING
AFS_AHS_EFS_FS_HS_
WFS_SIGNALING
Default Value
None.
Contained in the following commands:
GET BTS

ERSACCHUL
enableRSacchUL
The attribute is implemented as a list of values representing combinations of signaling
and allowed codec types and/or signaling. This list is present in Appendix.
For the binary representation 0 means that R-SACCH in DL on a per cell basis is not
applied for specified speech codec type and /or signaling. Value 1 means that RSACCH in DL is applied for specified speech codec type and/or signaling.
Value 0x00 has specific meaning and should be read as R-SACCH in DL is not applied
for any speech codec type.
This attribute is used to enable the featureR-SACCH in UL on a per cell basis for different codec types and /or signaling only for MS with R-ACCH_CAP = 1.
When enabling R-SACCH feature on BTS, where only old CUs are created, SET is
acked but ignored locally.
Validity Range
NOT_SET
AFS
AHS
AFS_AHS
EFS
AFS_EFS
AHS_EFS
AFS_AHS_EFS
FS
AFS_FS
AHS_FS
AFS_AHS_FS

630

Id:0900d8058024e358

A50016-G5100-B333-04-7619

BS-4x / 82 II / 240 / 241 / 240XL commands

EFS_FS
AFS_EFS_FS
AHS_EFS_FS
AFS_AHS_EFS_FS
HS
AFS_HS
AHS_HS
AFS_AHS_HS
EFS_HS
AFS_EFS_HS
AHS_EFS_HS
AFS_AHS_EFS_HS
FS_HS
AFS_FS_HS
AHS_FS_HS
AFS_AHS_FS_HS
EFS_FS_HS
AFS_EFS_FS_HS
AHS_EFS_FS_HS
AFS_AHS_EFS_FS_HS
WFS
AFS_WFS
AHS_WFS
AFS_AHS_WFS
EFS_WFS
AFS_EFS_WFS
AHS_EFS_WFS
AFS_AHS_EFS_WFS
FS_WFS
AFS_FS_WFS
AHS_FS_WFS
AFS_AHS_FS_WFS
EFS_FS_WFS
AFS_EFS_FS_WFS
AHS_EFS_FS_WFS
AFS_AHS_EFS_FS_WFS

A50016-G5100-B333-04-7619

Id:0900d8058024e358

631

BS-4x / 82 II / 240 / 241 / 240XL commands

HS_WFS
AFS_HS_WFS
AHS_HS_WFS
AFS_AHS_HS_WFS
EFS_HS_WFS
AFS_EFS_HS_WFS
AHS_EFS_HS_WFS
AFS_AHS_EFS_HS_WFS
FS_HS_WFS
AFS_FS_HS_WFS
AHS_FS_HS_WFS
AFS_AHS_FS_HS_WFS
EFS_FS_HS_WFS
AFS_EFS_FS_HS_WFS
AHS_EFS_FS_HS_WFS
AFS_AHS_EFS_FS_HS_
WFS
SIGNALING
AFS_SIGNALING
AHS_SIGNALING
AFS_AHS_SIGNALING
EFS_SIGNALING
AFS_EFS_SIGNALING
AHS_EFS_SIGNALING
AFS_AHS_EFS_SIGNALIN
G
FS_SIGNALING
AFS_FS_SIGNALING
AHS_FS_SIGNALING
AFS_AHS_FS_SIGNALIN
G
EFS_FS_SIGNALING
AFS_EFS_FS_SIGNALING
AHS_EFS_FS_SIGNALIN
G
AFS_AHS_EFS_FS_SIGN
ALING
HS_SIGNALING

632

Id:0900d8058024e358

A50016-G5100-B333-04-7619

BS-4x / 82 II / 240 / 241 / 240XL commands

AFS_HS_SIGNALING
AHS_HS_SIGNALING
AFS_AHS_HS_SIGNALIN
G
EFS_HS_SIGNALING
AFS_EFS_HS_SIGNALIN
G
AHS_EFS_HS_SIGNALIN
G
AFS_AHS_EFS_HS_SIGN
ALING
FS_HS_SIGNALING
AFS_FS_HS_SIGNALING
AHS_FS_HS_SIGNALING
AFS_AHS_FS_HS_SIGNA
LING
EFS_FS_HS_SIGNALING
AFS_EFS_FS_HS_SIGNA
LING
AHS_EFS_FS_HS_SIGNA
LING
AFS_AHS_EFS_FS_HS_S
IGNALING
WFS_SIGNALING
AFS_WFS_SIGNALING
AHS_WFS_SIGNALING
AFS_AHS_WFS_SIGNALI
NG
EFS_WFS_SIGNALING
AFS_EFS_WFS_SIGNALI
NG
AHS_EFS_WFS_SIGNALI
NG
AFS_AHS_EFS_WFS_SIG
NALING
FS_WFS_SIGNALING
AFS_FS_WFS_SIGNALIN
G
AHS_FS_WFS_SIGNALIN
G

A50016-G5100-B333-04-7619

Id:0900d8058024e358

633

BS-4x / 82 II / 240 / 241 / 240XL commands

AFS_AHS_FS_WFS_SIGN
ALING
EFS_FS_WFS_SIGNALIN
G
AFS_EFS_FS_WFS_SIGN
ALING
AHS_EFS_FS_WFS_SIGN
ALING
AFS_AHS_EFS_FS_WFS_
SIGNALING
HS_WFS_SIGNALING
AFS_HS_WFS_SIGNALIN
G
AHS_HS_WFS_SIGNALIN
G
AFS_AHS_HS_WFS_SIGN
ALING
EFS_HS_WFS_SIGNALIN
G
AFS_EFS_HS_WFS_SIGN
ALING
AHS_EFS_HS_WFS_SIGN
ALING
AFS_AHS_EFS_HS_WFS
_SIGNALING
FS_HS_WFS_SIGNALING
AFS_FS_HS_WFS_SIGNA
LING
AHS_FS_HS_WFS_SIGNA
LING
AFS_AHS_FS_HS_WFS_
SIGNALING
EFS_FS_HS_WFS_SIGNA
LING
AFS_EFS_FS_HS_WFS_S
IGNALING
AHS_EFS_FS_HS_WFS_
SIGNALING
AFS_AHS_EFS_FS_HS_
WFS_SIGNALING
Default Value
None.

634

Id:0900d8058024e358

A50016-G5100-B333-04-7619

BS-4x / 82 II / 240 / 241 / 240XL commands

Contained in the following commands:


GET BTS

ETOP
enableTOP
This attribute determines whether TOP(Temporary Overpower) is enabled or disabled
on cell basis for the specified codec type. See Appendix for the values.
Validity Range
NOT_SET
AFS
AHS
AFS_AHS
EFS
AFS_EFS
AHS_EFS
AFS_AHS_EFS
FS
AFS_FS
AHS_FS
AFS_AHS_FS
EFS_FS
AFS_EFS_FS
AHS_EFS_FS
AFS_AHS_EFS_FS
HS
AFS_HS
AHS_HS
AFS_AHS_HS
EFS_HS
AFS_EFS_HS
AHS_EFS_HS
AFS_AHS_EFS_HS
FS_HS
AFS_FS_HS
AHS_FS_HS
AFS_AHS_FS_HS

A50016-G5100-B333-04-7619

Id:0900d8058024e358

635

BS-4x / 82 II / 240 / 241 / 240XL commands

EFS_FS_HS
AFS_EFS_FS_HS
AHS_EFS_FS_HS
AFS_AHS_EFS_FS_HS
WFS
AFS_WFS
AHS_WFS
AFS_AHS_WFS
EFS_WFS
AFS_EFS_WFS
AHS_EFS_WFS
AFS_AHS_EFS_WFS
FS_WFS
AFS_FS_WFS
AHS_FS_WFS
AFS_AHS_FS_WFS
EFS_FS_WFS
AFS_EFS_FS_WFS
AHS_EFS_FS_WFS
AFS_AHS_EFS_FS_WFS
HS_WFS
AFS_HS_WFS
AHS_HS_WFS
AFS_AHS_HS_WFS
EFS_HS_WFS
AFS_EFS_HS_WFS
AHS_EFS_HS_WFS
AFS_AHS_EFS_HS_WFS
FS_HS_WFS
AFS_FS_HS_WFS
AHS_FS_HS_WFS
AFS_AHS_FS_HS_WFS
EFS_FS_HS_WFS
AFS_EFS_FS_HS_WFS
AHS_EFS_FS_HS_WFS
AFS_AHS_EFS_FS_HS_
WFS

636

Id:0900d8058024e358

A50016-G5100-B333-04-7619

BS-4x / 82 II / 240 / 241 / 240XL commands

Default Value
None.
Contained in the following commands:
GET BTS

ETXDIVTS
enableTxDivTimeShift
The attribute indicates whether Tx Diversity Time Shift is enabled or disabled for a BTS.
As a consequence all TRXs of the cell will operate in "double-power/half capacity" Mode
(called Coverage Mode) or in "normal-power/normal capacity" Mode (called Capacity
Mode).
The value 'TRUE' means that all CUs or FCUTRs in the a cell operate as CU pairs or
FCUTR pairs in a master slave mode. Pairs are defined as follows (k=0, 1, 2, etc.):
- A CU pair consists of the master CU (instance 2k) and the slave CU (instance 2k+1)
- A FCUTR pair consists of the master FCUTR (instance 2k) and the slave FCUTR
(instance 2k+1).
The two members of each pair should be wired to different antennas of the same cell
otherwise the combining loss would nullify the additional gain of the coverage mode. A
change of the attribute becomes effective after reconfiguration of the cell handled internally by the BTSE and causes a reset of the related CU or FCUMAIN objects. The BSC
takes care that the BTS object is locked whenever the value of the attribute is changed.

Validity Range
TRUE
FALSE
Default Value
FALSE (disabled)
Contained in the following commands:
GET BTS

EVTYP
eventType
This attribute specifies the type of failure event alarm.
Validity Range
COMMUNICATION_FAILU
RE_EVENT

A50016-G5100-B333-04-7619

Id:0900d8058024e358

637

BS-4x / 82 II / 240 / 241 / 240XL commands

QUAL_SERVICE_FAILUR
E_EVENT
PROCESSING_FAILURE_
EVENT
EQUIPMENT_FAILURE_E
VENT
ENVIRONMENTAL_FAILU
RE_EVENT
Default Value
None.
Contained in the following commands:
GETACTIVEALARMS BTSEP

EXCDIST
excessiveDistance(km)
This attribute indicates the distance limit to be used for call release when the distance
between Mobile Station and BTS exceeds the excessiveDistance. Value indicating more
35 km are valid only for extended cells. A change of the attribute becomes effective in
the next SACCH multiframe.
Validity Range
1 - 100
Default Value
100 Km
Contained in the following commands:
GET BTS

EXTMODE
extendedMode
This attribute indicates whether a channel instance operates in the extended mode
(usage of two radio timeslots) which is needed for extended cells. The value TRUE is
allowed only for even channel instances. Before an even channel instance N can be
created with the value TRUE for the extendedMode it must be guaranteed that channel
instance N+1 does not exist.
Validity Range
TRUE
FALSE
Default Value
FALSE

638

Id:0900d8058024e358

A50016-G5100-B333-04-7619

BS-4x / 82 II / 240 / 241 / 240XL commands

Contained in the following commands:


GET CHAN

A50016-G5100-B333-04-7619

Id:0900d8058024e358

639

BS-4x / 82 II / 240 / 241 / 240XL commands

f
F6FWID
ficom6FwId
This attribute provides information of the file ID and the FW version that is active on
a FICOM6 board.
Validity Range
39..39 characters string
Default Value
None.
Contained in the following commands:
GET F6VSWRP

FACCHQ
facchQual
This attribute defines the number of FACCH (stealing flags minus 1) to be received for
detecting a FACCH frame.
(step size 1 FACCH frame)
Validity Range
0-7
Default Value
5
Contained in the following commands:
GET BTS

FACHBT
fachBusyThreshold(dBm)
This attribute defines a threshold for the received signal level during handover procedure when mobile station transmits HANDOVER ACCESS or ASCI uplink access burst
message on the FACCH (Fast Associated Control Channel). A signal exceeding this
threshold is interpreted as a busy FACCH.
Validity Range
<ANY>
Default Value
None.

640

Id:0900d805805ca193

A50016-G5100-B333-04-7619

BS-4x / 82 II / 240 / 241 / 240XL commands

Contained in the following commands:


GET BTS

FBAND
frequencyBand
The attribute specifies the frequency band of the BCOM. It is highly recommended to set
this attribute to the correct value in order to ensure software checks for a consistent
wiring especially in case of dual band configurations.
It is the operator's responsibility to configure the correct value because the system
cannot check if the value fits to the equipped hardware.
Validity Range
Gsm850
Gsm900
Dcs1800
Pcs1900
NotSet
Default Value
NotSet
Contained in the following commands:
CREATE BCOM, GET BCOM, SET BCOM

FCUMAINWIRING
fcumainWiring
The attribute describes the Tx and Rx wiring of the FlexCU board to the combining
equipment. The attribute identifier cannot be present in the listOfRequiredAttributes
together with other attribute identifiers and it is not sent by the BTSE if a "Get FCUMAIN"
is done without the information element listOfRequiredAttributes.
The attribute is not visible at the RC.
Validity Range
choice tag
1 = 'variable'
tx0WiringPresence:
1 = the next 4 bytes contain object class & instance of the object wired to the TX output 0
0 = object class & instance don't follow
rxNWiringPresence: Octect position is variable

A50016-G5100-B333-04-7619

Id:0900d805805ca193

641

BS-4x / 82 II / 240 / 241 / 240XL commands

1 = the next 4 bytes contain object class & instance of the object wired to the RX output
N
0 = object class & instance don't follow
rxDWiringPresence: Octect position is variable
1 = the next 4 bytes contain object class & instance of the object wired to the RX output
D
0 = object class & instance don't follow
tx1WiringPresence: Octect position is variable
1 = the next 4 bytes contain object class & instance of the object wired to the TX output 1
0 = object class & instance don't follow
rxN1WiringPresence: Octect position is variable
1 = the next 4 bytes contain object class & instance of the object wired to the RX output
N1
0 = object class & instance don't follow
rxD1WiringPresence: Octect position is variable
1 = the next 4 bytes contain object class & instance of the object wired to the RX output
D1
0 = object class & instance don't follow
Default Value
None.
Contained in the following commands:
GET FCUMAIN WIRING

FCUMODE
fcuMode
This attribute specifies in which mode a FlexCU board shall operate.
A FlexCU in 'singleCUMode'
-

Does not allow the creation of the odd instance of the FCUTR
object;

Does not support the feature 'TX diversity time shift'. If the
value of the attribute 'enableTxDivTimeShift' is 'TRUE', an
appropriate FCUMAIN alarm is emitted and the FCUMAIN
and FCUTR instance are set to disabled;

Supports only 1 TRX with up to 4 RX branches

A FlexCU board in 'doubleCUMode' supports up to 2 TRX instances:

642

Id:0900d805805ca193

A50016-G5100-B333-04-7619

BS-4x / 82 II / 240 / 241 / 240XL commands

Support of two TRX instances ('enableTxDivTimeShift' is


'FALSE');
Support of 1 TRX with 'TX diversity time shift' ('enableTxDivTimeShift' is 'TRUE').

Validity Range
singleCUMode
doubleCUMode
Default Value
doubleCUMode
Contained in the following commands:
CREATE FCUMAIN, GET FCUMAIN

FILE
file
This attribute specifies the file within the destinationDirectory on the LMT hard disk
where the BTSE alarm buffer sw will be copied (UPLBTSLOG) or where the IDT file will
be copied (UPLLIDF).
Validity Range
1..30 characters string
Default Value
None.
Contained in the following commands:
UPLBTSLOG SOFTWARE-MANAGEMENT, UPLLIDF REMINV

FILEFWV
fwVersion
This attribute states the name and version of the fwImage file. The file is transferred to
the dedicated board to perform the FW upgrade.
Validity Range
26..26 characters string
Default Value
None.
Contained in the following commands:
FWUPGRADE BTSM

A50016-G5100-B333-04-7619

Id:0900d805805ca193

643

BS-4x / 82 II / 240 / 241 / 240XL commands

FILEID
fileId
The FileId is a parameter used within the SW download procedures
and not of the type 'GET'. The corresponding attribute is swLoadCurrentFileId and is related only to the swLoad-header file. All characters of the ASCII string are to be in upper case. However, the SW
parts in the BTSE handling the file Id are to be case tolerant.
This attribute is a string of 12 alphanumerical characters with the following format:
ASCII String for:

For download
of test SW from
local LMT acc.

For download
of boot SW
from local LMT
acc.

for swLoadheader file

HScnvvss.SWL

HSTTvvss.SWL

HSBBvvss.SWL

for the VAM


table file

VScnvvss.VAM

VSTTvvss.VAM

VSBBvvss.VAM

for swImages

BTSrrrhh.SWI

BTTrrrhh.SWI

BTBrrrhh.SWI

for PID files

PSBBvvss.PID

hh, cn, vv and ss are identical with the corresponding parts of the
FILESWV - please note that thevalues of 'hh' in the FileId of
swImages do not reflect the BTSE family but reflect the HW version
of the board. (eg.BTSBIX01.SWI is for the CU and the file
BTSBIX07.SWI is for newer CU-variants, eg. the ECU).

The 3 characters used for 'rrr' identify different units:


rrr

BS240, BS241, BS240XL,


BS240SR,BS241SR, BS240XLSR,
BS40, BS40II, BS41, BS82, BS82II

BCX

for COBA

BIX

for CU

LMX

for LMU (only BS240, BS241, BS240XL)

g This value may only be used in conjunction with the FileVersion "00 " (indicating the
destination "Easy-Disk").
Validity Range
12..12 characters string
Default Value
None.

644

Id:0900d805805ca193

A50016-G5100-B333-04-7619

BS-4x / 82 II / 240 / 241 / 240XL commands

Contained in the following commands:


ACTIVATE BTSM, ACTIVATE_DELAYED BTSM, FWUPGRADE BTSM

FILESWV
fileVersion
The File Version is a parameter used within the SW download procedures and not of the
type 'GET'. The corresponding attribute is swLoadCurrentVersion and is coded identical
as File Version. However the allowed values for 'hh' are different because wLoadCurrentVersion is related only to the swLoad-header file.
Validity Range
ASCII string: cn-hh-vv-ii-ss-pp_yy-mm-dd, where:
cn

Version part (network operator code)


01 = Ciphering A5.0 + A5.1 + A5.2
02 = Ciphering A5.0 + A5.2 12
03 = Ciphering A5.0 only

hh

Version part (HW/SW compatibility code)

vv

Version part (feature package code)


02 = BR 2.0
03 = BR 2.1
04 = BR 3.0
07 = BR 3.7
08,09 = BR 4.0
10 = BR 4.5
11 = BR 5.0
12 = BR 5.5
13 = BR 6.0
14 = BR 6.01
15 = BR 6.02
16 = BR 7.0 / 7.01
17 = BR 8.0
18 = BR 9.0
19 = BR 10.0

ii: Version part (sub-feature package code). This field assumes the values: 21 (BTSplus
mainline), 26 (BTSplus basic), 25 (BTSplus eMicro)
ss: Version part (actual state)
pp: Patch version (usually 00)
yy-mm-dd production date (optional)
Note:

A50016-G5100-B333-04-7619

Id:0900d805805ca193

645

BS-4x / 82 II / 240 / 241 / 240XL commands

1) For the SWL file of the downloadable test SW of BS240, BS241, BS240XL, and BS40,
BS40II, BS41, BS82II, BS82, BS240XS, BS288 the following special value is used:
cn = TT
2) For the SWL file of the downloadable boot SW of BS240, BS241, BS240XL, and
BS40, BS40II, BS41, BS82II, BS82, BS240XS, BS288 the following special value is
used:
cn = BB
In addition to the ASCII string described above values, the following values are allowed
for generic filedownload.
"00" ....Destination ID for Easy-Disk (remaining 24 characters are filled with blanks)
"01" ....Destination ID for Light-Disk Partition 1 (reserved)
"02" ....Destination ID for Light-Disk Partition 2 (reserved)
"03" ....Destination ID for Light-Disk Partition 3 (reserved)
Default Value
None.
Contained in the following commands:
ACTIVATE BTSM, ACTIVATE_DELAYED BTSM

FILETYPE
FileType
This parameter specifies the file type to be transferred.
Validity Range
ALARM_BUFFER
TRACE_FILE
Default Value
None.
Contained in the following commands:
UPLBTSLOG SOFTWARE-MANAGEMENT

FPGAFWVER
fpgaFwVer
This attribute gives information on the FPGA FW images that are contained in the
board's flash prom together with an indication of the active version. Available FPGAimage-types are identifiable via their file-ID. Up to 4 FPGA-images can be displayed on
GUI. Their order is not fixed
The attribute identifier cannot be present in the listOfRequiredAttributes together with
other attribute identifiers and it is not sent by the BTSE if a "Get FCUMAIN"/"Get CU"is
done without the information element listOfRequiredAttributes.

646

Id:0900d805805ca193

A50016-G5100-B333-04-7619

BS-4x / 82 II / 240 / 241 / 240XL commands

Validity Range
1 to 4 items of
FPGAfwVer

39..39 characters
string

activeFlag

active
stored

Default Value
None.
Contained in the following commands:
GET CU, GET CU FWID, GET FCUMAIN, GET FCUMAIN FWID

FRANOFFS
frameNumberOffset
This attribute allows to adjust the TDMA frame number offset for a cell. Equal frame and
burst number offsets result in synchronized TDMA frames and synchronized TDMA
frame numbers.
This attribute is only meaningful enableInterSiteSync is set to 'TRUE'.
Validity Range
0 - 255
Default Value
0
Contained in the following commands:
GET BTS

FWVER
firmwareVersion
This attribute provides the firmware version stored on the ETHCON board.
Validity Range
0 - 255
<NULL>
Default Value
None.
Contained in the following commands:
GET ETHCON

A50016-G5100-B333-04-7619

Id:0900d805805ca193

647

BS-4x / 82 II / 240 / 241 / 240XL commands

g
GN<x>
gain0(dBi*1<x>)
Attribute data provided by the TMA.
The attribute shows the gain of the operating band<X> in (dBi * 10).
Validity Range
0 - 255
<NULL>
Default Value
None.
Contained in the following commands:
GET TMA

GNA
gainAdjust(dB)
The attribute provides the attenuation value which is actually set for the RX amplifier
chain of the combiner, either the DIP switch value, the aligned database value or the
value due to the fail safe mechanism.
UNKNOWN means that no hardware is equipped.
ILLEGAL_VALUE means a wrong DIP switch setting of an (F)DUAMCO (formerly indicated as 7 dB).
Validity Range
In commands GET DILNA, GET DULNA, GET F6LNA:
N_00
N_01
N_02
N_03
N_04
N_05
N_06
N_07
N_08
N_09
N_10
N_11

648

Id:0900d8058051e6d2

A50016-G5100-B333-04-7619

BS-4x / 82 II / 240 / 241 / 240XL commands

N_12
ILLEGAL_VALUE
UNKNOWN
<NULL>
In commands GET DILNA, GET DULNA:
N_00
N_01
N_02
N_03
N_04
N_05
N_06
N_07
N_08
N_09
N_10
N_11
N_12
ILLEGAL_VALUE
UNKNOWN
Default Value
None.
Contained in the following commands:
GET DILNA, GET DULNA, GET F6LNA

GNADB
gainAdjustDb
The attribute sets the attenuation value of an MFDUAMCO RX amplifier chain in the
database. The value will be aligned with the combiner if a MFDUAMCO is equipped. If
the value DIP is set, the MFDUAMCO DIP switch setting will be used.
The attribute is meaningless if an old DUAMCO or FDUAMCO is equipped. Nevertheless the value will be stored in the database and used if an MFDUAMCO will be
equipped later on.
Validity Range
N_00
N_01
N_02

A50016-G5100-B333-04-7619

Id:0900d8058051e6d2

649

BS-4x / 82 II / 240 / 241 / 240XL commands

N_03
N_04
N_05
N_06
N_07
N_08
N_09
N_10
N_11
N_12
DIP
Default Value
DIP
Contained in the following commands:
CREATE DULNA, CREATE F6LNA, GET DULNA, GET F6LNA, SET DULNA, SET
F6LNA

GNR
gainResolution(dB*4)
Attribute data provided by the TMA.
Validity Range
0 - 255
<NULL>
Default Value
None.
Contained in the following commands:
GET TMA

GSMTIME
gsmTime
This attribute represents the current frame number of the radio interface. It is counted
as a binary presentation 'frame number modulus 42432'.
Validity Range
0 - 42432
<NULL>

650

Id:0900d8058051e6d2

A50016-G5100-B333-04-7619

BS-4x / 82 II / 240 / 241 / 240XL commands

Default Value
None.
Contained in the following commands:
GET BTS

GTWADRV4
gatewayAddressIPv4
This attribute specifies IPv4 address of the default IP gateway including the subnetwork
information.
The address is input in the usual IPv4 format. The subnetwork is added in CIDR notation.
Example for CIDR notation:
192.168.2.7/24 corresponds to the host address 192.168.2.7 with subnet mask
255.255.255.0

g Value 0.0.0.0/0 and 0.0.0.0 are intrepreted as attribute not set.


This attribute is visible and configurable only in phase 2 in LMT local.
Validity Range
0..18 characters string
Default Value
""
Contained in the following commands:
GET BTSEP NOSWL, SET BTSEP

A50016-G5100-B333-04-7619

Id:0900d8058051e6d2

651

BS-4x / 82 II / 240 / 241 / 240XL commands

h
HOPMODE
hoppingMode
This attribute specifies whether baseband hopping or synthesizer hopping is to be done.
This attribute can be changed only when hopping is switched off (Attribute btsIsHopping). A prerequisite for synthesizer hopping is that the corresponding HW (TPU + PA)
is installed.
Validity Range
BBHOP
SYNHOP
Default Value
None.
Contained in the following commands:
GET BTS

HSN
hoppingSequenceNumber
This attribute determines the order in which the allocated frequencies are used.
This parameter is used in the frequency hopping algorithm. Any instance of the CHAN
object, which is not assigned to any explicit frequency hopping system instance should
contain the default value 0 for this attribute.
Changing this attribute is allowed only if there is no hopping (i.e. attribute btsIsHopping
= FALSE).
Validity Range
0 - 63
Default Value
0
Contained in the following commands:
GET CHAN

652

Id:0900d8058024e371

A50016-G5100-B333-04-7619

BS-4x / 82 II / 240 / 241 / 240XL commands

i
INSD
installDate
Attribute data provided by the TMA.
Validity Range
0..6 characters string
Default Value
None.
Contained in the following commands:
GET TMA

INSID
installerId
Attribute data provided by the TMA.
Validity Range
0..5 characters string
Default Value
None.
Contained in the following commands:
GET TMA

INTAVEPAR
intaveParameter
This attribute contains the measurement and averaging period for the interference classification of idle traffic channels in units of SACCH multiframes.
Validity Range
1 - 31
Default Value
31
Contained in the following commands:
GET BTS

A50016-G5100-B333-04-7619

Id:0900d80580592b9c

653

BS-4x / 82 II / 240 / 241 / 240XL commands

INTCLASS
enableInterferenceClass
This attribute indicated whether the interference classification of idle traffic channels is
enabled or disabled.
A change of the attribute becomes effective in the next SACCH multiframe.
A consequence of the value 'disabled' is that no 'RF resource indication' messages are
sent to the BSC.
(TRUE = enabled)
Validity Range
FALSE
TRUE
Default Value
TRUE (enabled)
Contained in the following commands:
GET BTS

INTINF
interfaceInformation
This attribute is used to configure one of the envaBTSE instances with the following
information:
positive logic with external detector
or
negative logic with external detector
Validity Range
low
high
Default Value
None.
Contained in the following commands:
CREATE ENVABTSE, GET ENVABTSE, SET ENVABTSE

INTLVBND
interferenceLevelBoundaries
This attribute defines the boundary limits of five interference bands for the unallocated
timeslots.
The BSC maps the averaged interference level measurements into these five bands.
A change of the attribute becomes effective in the next SACCH multiframe.

654

Id:0900d80580592b9c

A50016-G5100-B333-04-7619

BS-4x / 82 II / 240 / 241 / 240XL commands

The validity range of the attribute is 0 ... 63 (less than -110 dBm...more than -48 dBm)
in steps of 1 dBm.
Validity Range
intThrBou1

0 - 63

intThsBou2

0 - 63

intThsBou3

0 - 63

intThsBou4

0 - 63

intThsBou5

0 - 63

Default Value
intThrBou1 : 2
intThsBou2 : 6
intThsBou3 : 12
intThsBou4 : 22
intThsBou5 : 63
Contained in the following commands:
GET BTS

IPADR
ipAddress
This attribute specifies IP address of the host which shall respond to the ping request.
The address is input in the usual IPv4. Length may vary from minimum length (7 ) ->
1.3.6.9 up to maximum length (15) -> 192.120. 110.124
Validity Range
7..15 characters string
Default Value
None.
Contained in the following commands:
PING BTSEP

A50016-G5100-B333-04-7619

Id:0900d80580592b9c

655

BS-4x / 82 II / 240 / 241 / 240XL commands

l
L1CTRLTS
layer1ControlTs
This attribute defines in case of a LOOP configuration which dedicated layer 1 16kbit/s
subchannel is to be used for the layer 1 supervision. In a star or multidrop configuration
the given time slot is used for a loopback supervision.
Below are indicated some more detailed information about the attribute validity range:
- TimeSlotNumber for Time Slot in 2 Mb/s link:
validity range: 1..31 (if dedicated 16k subchannel is used fo supervision
- TimeSlotNumber for Time Slot in 1,5 Mb/s link:
validity range: 1..21 (if dedicated 16k subchannel is used fo supervision
- SubSlotNumber for SubSlot within time slot
validity range: 0..3 (if dedicated 16k subchannel is used fo supervision

Validity Range
TSL

0 - 31

SSL

0-3

Default Value
TimeSlotNumber:
0 (deactivated)
SubSlotNumber:
octet #2 = 3
octet #4 = 0
Contained in the following commands:
CREATE BPORT, GET BPORT, SET BPORT

L1PT
layer1ProtocolType
"This attribute defines the type of protocol that is used on layer 1 of the Abis-line. One
of the following values has to be set by the operator at installation time for a PCM30 line:
The value 'pcm30crc4' means that a cyclic redundancy check (CRC4) is performed, the
value 'pcm30noncrc4doubleframe' means that CRC4 is not performed and that the line
remains in Doubleframe mode.

656

Id:0900d80580592b9e

A50016-G5100-B333-04-7619

BS-4x / 82 II / 240 / 241 / 240XL commands

The value 'pcm24sf' means the 'superframe' format is used.


The value 'pcm24crc6esf' means the 'extended superframe' format is used and a cyclic
redundancy check (CRC6) is performed.
Validity Range
pcm30crc4
pcm30noncrc4doubleframe
pcm24sf
pcm24crc6esf
Default Value
None.
Contained in the following commands:
CREATE BPORT, GET BPORT

L1RAT
layer1RemoteAlarmType
This attribute defines how the signalling of a remote alarm is done for both detection and
transmission. It must be set accordingly in the remote environment. 'Special Bit Robbing'
is allowed only for PCM24 and means that a special bit (bit 2) is used for signalling a
remote alarm.
Validity Range
ProtocolSignalling
SpecialBitRobbing
Default Value
ProtocolSignalling
Contained in the following commands:
CREATE BPORT, GET BPORT, SET BPORT

LAPDCH
lapdChannel
This attribute exists for only for LAPDLE. It identifies the BPortNumber, Timeslot
Number and Subslot Number allocated on the Abis-interface for the LAPD signalling
links to the BSC.
- BPortNumber (BPORT)
00-07 for BTSplus Mainline (enums: BPORT0, BPORT1, ..., BPORT7)
00

for eMICRO (enum: BPORT0)

00-03 for BTSXS (enum: BPORT0, ..., BPORT3)

A50016-G5100-B333-04-7619

Id:0900d80580592b9e

657

BS-4x / 82 II / 240 / 241 / 240XL commands

( ! ) For BS82II only BPortNumber 00-03 is allowed


- the TSL field has the following ranges:
- 1... 31 for PCM30
- 0... 24 for PCM24
- the SSL field has the following bit associations:
- a (bits 8.7)

SSL0_16KB

- b (bits 6,5)

SSL1_16KB

- c (bits 4,3)

SSL2_16KB

- d (bits 2,1)

SSL3_16KB

- 64 kb/s signalling

FULL_64KB

Validity Range
BPORT

BPORT0
BPORT1
...
BPORT7

TSL

1 - 31

SSL

SSL0_16KB
SSL1_16KB
SSL2_16KB
SSL3_16KB
FULL_64KB

Default Value
None.
Contained in the following commands:
CREATE LAPDLE, GET LAPDLE

LAPDOVLT
lapdOverloadTimer(sec)
The attribute defines the time between two subsequent 'LAPD overload' messages (in
seconds), as long as any radio signalling LAPD link on Abis is overloaded.
The validity range is indicated in seconds.
Validity Range

658

lapdOverloadTimer

1 - 60

lapdUsageOverloadTimer

0.5 - 10.0

Id:0900d80580592b9e

A50016-G5100-B333-04-7619

BS-4x / 82 II / 240 / 241 / 240XL commands

Default Value
lapdOverloadTimer: 1 second
lapdUsageOverloadTimer: 1 second
Contained in the following commands:
GET BTSM OVERLOAD

LAPDOVLTH
lapdOverloadThresholds(%)
The thresholds give the percentage of the LAPD transmit queue
filling, allowed range is 10 to 100 (decimal):
a)

first level upper threshold : when exceeded sending of measurement report messages on Abis will be suspended.

b)

second level upper threshold : when exceeded on any of the


LAPD links the periodical sending 'LAPD overload' message is
started.

c)

first level lower threshold: when filling level falls below, sending
of measurement reports on Abis will resume.

d)

second level lower threshold : when filling level falls below,


sending of 'LAPD overload' indication will be stopped.

For thresholds the following restriction is valid:


-

first level lower threshold < first level upper threshold =<
second level lower threshold < second level upper threshold

Default Value:
80

first level upper threshold

60

first level lower threshold

90

second level upper threshold

80

second level lower threshold

10

firstLevReductionStep

Validity Range
firstLevUpperThreshold

10 - 100

firstLevLowerThreshold

10 - 100

firstLevReductionStep

10 - 100

secLevUpperThreshold

10 - 100

secLevLowerThreshold

10 - 100

A50016-G5100-B333-04-7619

Id:0900d80580592b9e

659

BS-4x / 82 II / 240 / 241 / 240XL commands

Default Value
None.
Contained in the following commands:
GET BTSM OVERLOAD

LAPDOVLTRXL
lapdOverloadTRXList
This attribute indicates a list of congested TRX instances, up to 48. Congestion in this
context means that a certain threshold in the LAPD transmit queue has been exceeded,
(second level upper threshold as defined in attribute lapdOverloadThresholds).
Some details about the validity range values are indicated:
0=<N=<48, 2=<n=<194

Validity Range
1 to 24 items of
Pathname
Default Value
None.
Contained in the following commands:
GET BTSM OVERLOAD

LCONF
lineConfiguration
This attribute defines the configuration of the BTSEs on the Abis
interface.
Notes:

660

a)

'star' means either a BTSE which is directly connected to the


BSC or the last BTSE of a multidrop chain.

b)

In general 'star' is allowed only for even BPORT instances.


Only for hh-ii = 04-01 'star' may be used also for odd BPORT
instances (2k+1, k=0, 1, 2, 3) - in this case the related even
BPORT instance (2k, k=0, 1, 2, 3) must be configured as 'star'
too.

c)

more information can be found in the document 'Configuration


Rules for BTSE Abis Line Interface'.

Id:0900d80580592b9e

A50016-G5100-B333-04-7619

BS-4x / 82 II / 240 / 241 / 240XL commands

Validity Range
star
multidrop
loop
starX
Default Value
None.
Contained in the following commands:
CREATE BPORT, GET BPORT, SET BPORT

LIMP
lineImpedance
This attribute defines the impedance setting of the related Abis
(BPort) interface.
Notes:
a)

On a COBA2P8 the adjustment of the impedance is done by


DIP switches. So the only acceptedvalue on a COBA2P8 is
'AccDIP'.

b)

On a COBA4P12 the adjustment is performed by software. So


the value must be 'Imp100or120Ohm' or 'Imp75Ohm'.

c)

If a value which is not allowed is entered the BTSE SW will


answer with a NACK.

d)

The initial value 02 will be changed by BTSE subsystem A1 to


00 in case of COBA4P12."

e)

In case of backup from COBA2P8 to COBA4P12 it is handled


"fault tolerantly", SET message will be acknowledged and
alarm will be issued. A1 subsystem will change value of the
attribute to appropriate default value 00 automatically.

Validity Range
Imp100or120Ohm
Imp75Ohm
accDIP
Default Value
accDIP (fully correct for COBA2P8 internal used by subsystem DM)
Contained in the following commands:
CREATE BPORT, GET BPORT, SET BPORT

A50016-G5100-B333-04-7619

Id:0900d80580592b9e

661

BS-4x / 82 II / 240 / 241 / 240XL commands

LMTLSESS
lmtLogonSession
This attribute indicates if a LMT session is active or not.
Validity Range
NOT_ACTIVE
ACTIVE
Default Value
NOT_ACTIVE
Contained in the following commands:
GET BTSEP NOSWL

LMTLTIME
lmtLogonTime
This attribute specifies the date and time of the logon attempt. It is set by the BTSE when
the T- interface message 'Logon' from the local LMT is received.
Validity Range
year

1990 - 2037

month

1 - 12

day

1 - 31

hour

0 - 23

minute

0 - 59

second

0 - 59

offsetHour

-12 - 14

offsetMinute

0 - 45

Default Value
year

: 1995

month

:8

day

:1

hour

:0

minute

:0

second

:0

Contained in the following commands:


GET BTSEP NOSWL

LMTUAL
lmtUserAccessLevel

662

Id:0900d80580592b9e

A50016-G5100-B333-04-7619

BS-4x / 82 II / 240 / 241 / 240XL commands

This attribute indicates the LMT user profile.


Validity Range
READ_ONLY
COMMAND
READ_WRITE
ACCESS_CONTROL_MA
NAGEMENT
SECURITY_OPERATOR
NOT_DEFINED
Default Value
NOT_DEFINED
Contained in the following commands:
GET BTSEP NOSWL

LMTUNAME
lmtUserName
The user name consists of a character string containing maximal 7
characters for the user name. The user name must be terminated by
a NUL character value (last byte of the user name). The content of
this attribute is identical with the content of the information element
'user identification' of the T-interface message 'Logon'.
Default Value: octet 3-10 = 00, octet 2 = 07
Validity Range
1..14 characters string
Default Value
octet 3-10 = 0, octet 2 = 7
Contained in the following commands:
GET BTSEP NOSWL

LNAMDB
lnaModeDb
The attribute sets the LNA mode value of an MFDUAMCO RX path in the database. The
value will be aligned with the combiner if a MFDUAMCO is equipped. If the value DIP is
set, the MFDUAMCO DIP switch setting will be used.
The attribute is meaningless if an old DUAMCO or FDUAMCO is equipped. Nevertheless the value will be stored in the database and used if an MFDUAMCO will be
equipped later on.

A50016-G5100-B333-04-7619

Id:0900d80580592b9e

663

BS-4x / 82 II / 240 / 241 / 240XL commands

Validity Range
MUCO_MODE
AMCO_MODE
DIP
Default Value
DIP
Contained in the following commands:
CREATE DULNA, CREATE F6LNA, GET DULNA, GET F6LNA, SET DULNA, SET
F6LNA

LNAMODE
lnaMode
This attribute indicates the current amplification mode of a DUAMCO_LNA or
DIAMCO_LNA. (The information is derived from the setting of the DIP switch 'mode
switch' and from the actual situation e.g. regarding the TMA) This attribute is 'readonly'.
Validity Range
MUCO_MODE
AMCO_MODE
UNKNOWN
Default Value
UNKNOWN
Contained in the following commands:
GET DILNA, GET DULNA, GET F6LNA

LNAPRED
lnaPredecessor
This attribute is optional and indicates the wiring of the RX input of a DUAMCO_LNA/
DIAMCO_LNA to the RX cascade output (RXCA) of another
DUAMCO_LNA/DIAMCO_LNA or to the RX output of a TMA.
From SW point of view the FDUAMCO is considered just as an HW variant of the
DUAMCO, so an extra term like 'FDUAMCO_LNA' is not introduced.
If there is no wiring the operator must not provide a value for the attribute.
If there is no wiring and the operator enters a value for the attribute he can correct the
error only by a deletion of the object and a re-creation of the object.
Detailed information about the validity range:
predecessor (Type):
DULNA (not allowed for BS82II)

664

Id:0900d80580592b9e

A50016-G5100-B333-04-7619

BS-4x / 82 II / 240 / 241 / 240XL commands

DILNA (not allowed for BS82II)


F6LNA: [0-3]
TMA
predecessor (Rack):
RACK0
RACK1
RACK2
If predecessor(type) is TMA the predecessor(rack) must be the same as the rack of the
DILNA/DULNA, i.e. the TMA connected to a DILNA/DULNA must be created in the same
rack as the DILNA/DULNA object.
predecessor (relative number):
DULNA 0 ... 7
DILNA 0 ... 7 (for BS240XL only 4 ... 7)
TMA 0 ... 15 (for BS240XL only 12 ... 15)
Validity Range
In commands CREATE DILNA, CREATE DULNA, CREATE F6LNA:
predType

DILNA

predRack

RACK0
RACK1
RACK2

predNo

DILNA0
DILNA1
...
DILNA7

DULNA

predRack

RACK0
RACK1
RACK2

predNo

DULNA0
DULNA1
...
DULNA7

TMA

predRack

RACK0
RACK1
RACK2

predNo

TMA0
TMA1
...
TMA15

A50016-G5100-B333-04-7619

Id:0900d80580592b9e

665

BS-4x / 82 II / 240 / 241 / 240XL commands

F6LNA

predRack

RACK0
RACK1
RACK2

predNo

F6LNA0
F6LNA1
...
F6LNA3

In commands GET DILNA, GET DULNA, GET F6LNA:


predType

DILNA

predRack

RACK0
RACK1
RACK2

predNo

DILNA0
DILNA1
...
DILNA7

DULNA

predRack

RACK0
RACK1
RACK2

predNo

DULNA0
DULNA1
...
DULNA7

TMA

predRack

RACK0
RACK1
RACK2

predNo

TMA0
TMA1
...
TMA15

F6LNA

predRack

RACK0
RACK1
RACK2

predNo

F6LNA0
F6LNA1
...
F6LNA3

666

Id:0900d80580592b9e

A50016-G5100-B333-04-7619

BS-4x / 82 II / 240 / 241 / 240XL commands

<NULL>
Default Value
None.
Contained in the following commands:
CREATE DILNA, CREATE DULNA, CREATE F6LNA, GET DILNA, GET DULNA,
GET F6LNA

LOCALADDR
localAddress
Local IP address of the Circuit Emulation Service Tunnel. The address is input in the
usual IPv4 format. For addressing examples please see also attribute ipAddress. The
object must be locked before modifying the address via the SET command.
Validity Range
7..15 characters string
Default Value
None.
Contained in the following commands:
CREATE CESTUNNEL, GET CESTUNNEL, SET CESTUNNEL

LOCLUDP
localUdpPort
Local UDP port number of the CESPW instance. It is recommended to use identical port
numbers for the local and the peer UDP port. The object must be locked before modifying the port number via the SET command.
Validity Range
49152 - 65535
Default Value
None.
Contained in the following commands:
CREATE CESPW, GET CESPW, SET CESPW

LOCNAME
locationName
This attribute is a ASCII string (max 37 characters) which identifies a
location.
Default Value: EARTH

A50016-G5100-B333-04-7619

Id:0900d80580592b9e

667

BS-4x / 82 II / 240 / 241 / 240XL commands

Validity Range
1..37 characters string
Default Value
None.
Contained in the following commands:
GET BTSEP NOSWL, SET BTSEP

LOSPKTTH
lostPacketThreshold
This attribute determines minimum number of lost packets per polling period within
CESPW which shall trigger the packet loss state.
Validity Range
1 - 100
Default Value
1
Contained in the following commands:
CREATE CESTUNNEL, GET CESTUNNEL, SET CESTUNNEL

LPDLMSAT
lapdleLinkSatellited
The attribute informs the BTSE SW about the settings in the BSC regarding the
presence of a satellite on the Abis interface. The attribute is sent only during the 'BTSE
Alignment Procedure'. The BTSE SW stores the value only as information for the operator. However when the attribute is stored the BTSE SW performs a semantic check
which compares the value of lapdmLinkSatellited with the value of the attribute sAbisLinkSatellited (ABISLKSAT). The BTSE SW reports a minor alarm if both values do not
match. The BTSE object is set to enabled.degraded as long as the alarm is active. In
order to clear the alarm the operator has to take steps that LPDLMSAT and ABISLKSAT
have a consistent value - a consequence of this action is an interruption of the Abis link
(as a change of ABISLKSAT is only possible at the BTSE-LMT in phase 2 and a change
of LPDLMSAT requires a deletion and re-creation of the BTSM object at the BSC-LMT
or at the RC).
Validity Range
terrestrialConnection
satelliteConnection
Default Value
terrestrialConnection (corresponds in the BSC to 'LPDLMSAT=FALSE')

668

Id:0900d80580592b9e

A50016-G5100-B333-04-7619

BS-4x / 82 II / 240 / 241 / 240XL commands

Contained in the following commands:


GET BTSM NOSWL

LRU
lru
This attribute describes an object class and instance of a specific board that is affected
by the firmware upgrade.
Validity Range
siemensHw

HwP
HwXS

typeOfHw

Cu
Coba
Fcumain
Duamco
Ficom6

rackNbr

0-2

boardNbr

0 - 11

Default Value
None.
Contained in the following commands:
FWUPGRADE BTSM

LSIND
lineStatusIndication
This attribute identifies the PCM link status values, that additionally
will be displayed via LED(s) at the LI or COBA/COSA. More than one
status might be valid at a time.
Bit 0: RemoteAlarmIndication
01

TRUE

00

FALSE always FALSE in case of ISDN S0

Bit 1: FrameSynchronizationLoss
01

TRUE

00

FALSE

Bit 2: CRCFailure
01

TRUE

00

FALSE always FALSE in case of ISDN S0

A50016-G5100-B333-04-7619

Id:0900d80580592b9e

669

BS-4x / 82 II / 240 / 241 / 240XL commands

Bit 3: NoLevel (Line is broken)


01

TRUE

00

FALSE

Bit 4: CRCFailureRemoteEnvironment
01

TRUE

00

FALSE always FALSE in case of ISDN S0

Bit 5: BitErrorRate > lowerThreshold of 'bitErrorRateThresholds'


01

TRUE

00

FALSE always FALSE in case of ISDN S0

Bit 6: BitErrorRate > upperThreshold of 'bitErrorRateThresholds'


01

TRUE

00

FALSE always FALSE in case of ISDN S0

Bit 7: PromptMaintenanceAlarmIndication
01

TRUE

00

FALSE

Validity Range
RemoteAlarmInd

FALSE
TRUE

FrameSynchroniza- FALSE
tionLoss
TRUE
CRCFailure

FALSE
TRUE

NoLevel

FALSE
TRUE

CRCRemoteEnviro- FALSE
ment
TRUE
BERTLowerThresh- FALSE
old
TRUE
BERTUpperThresh- FALSE
old
TRUE
PromptMaintenanceAlarmInd

FALSE
TRUE

670

Id:0900d80580592b9e

A50016-G5100-B333-04-7619

BS-4x / 82 II / 240 / 241 / 240XL commands

<NULL>
Default Value
None.
Contained in the following commands:
GET BPORT

A50016-G5100-B333-04-7619

Id:0900d80580592b9e

671

BS-4x / 82 II / 240 / 241 / 240XL commands

m
MACADDR
macAddress
This attribute provides the MAC address of the Ethernet port instance. Attribute is coded
as a string with 17 characters with hexadecimal representation of the MAC address (e.g.
09:03:20:ae:ec:7b).
Validity Range
17..17 characters string
Default Value
None.
Contained in the following commands:
GET COBAETHINTF

MAIO
maio
"Hopping physical channels on the same timeslot with the same mobile allocation (contained in the aRFCNList) must use the same value of hoppingSequenceNumber and different values for MAIO (Mobile Allocation Index Offset). This prevents frequency
collision.
The maximum value of mAIO depends on the number of frequencies in the attached
ARFCNList. For a set of N allocated frequencies in the ARFCNList there must be N different values for mAIO (0...N-1).
Any instance of the object CHAN which is not assigned to any explicit frequency hopping
system instance should contain the default value 0 for this attribute."
Changing this attribute is allowed only if there is no hopping (i.e. attribute btsIsHopping
= FALSE).
Validity Range
0 - 63
Default Value
0
Contained in the following commands:
GET CHAN

MAXGN
maxGain(dB*4)
Attribute data provided by the TMA.

672

Id:0900d8058051e910

A50016-G5100-B333-04-7619

BS-4x / 82 II / 240 / 241 / 240XL commands

Validity Range
0 - 255
<NULL>
Default Value
None.
Contained in the following commands:
GET TMA

MAXPDV
maxPdv(ms)
The attribute defines the maximum packet delay variation value. It is used for dimensioning of the jitter buffer. The object must be locked before modifying the maxPdv value via
SET command.
Validity Range
0.125 - 30.000
Default Value
2.000
Contained in the following commands:
CREATE CESPW, GET CESPW, SET CESPW

MINGN
minGain(dB*4)
Attribute data provided by the TMA.
Validity Range
0 - 255
<NULL>
Default Value
None.
Contained in the following commands:
GET TMA

MOBALLOC
arfcnList
mobileAllocation / trxFrequency

A50016-G5100-B333-04-7619

Id:0900d8058051e910

673

BS-4x / 82 II / 240 / 241 / 240XL commands

This attribute is contained in the functional objects transceiver and


channel.
Octet 2 tells the number of frequencies in the list. The remaining
number of octets of this information element (aRFCNList) is twice the
value of this field.
If the attribute is contained in a message related to the transceiver the
value of "Number of ARFCNs in List" must be 1, i.e. only one ARFCN
is allowed. (The name at the GUI is 'trxFrequency" in this case.
If the attribute is contained in a message related to the channel (The
name at the GUI is 'mobileAllocation" in this case.) the value of
"Number of ARFCNs in List" is : <00-40>, <0- 64> (decimal)
The value 0 has the special meaning that the corresponding channel
instance is not assigned to any frequency hopping system instance
and that the BTSE has to use the ARFCN value of the TRX which
contains the channel.
ARFCN1..ARFCNn shall be contained in ascending order with no
duplicates.

cellAllocationNumber

Hex

Decimal

GSM900 "BB900"

0001 ... 007C

1 ... 124

GSM EXTENDED
"F2ONLY900"

0000 ... 007C

0 ... 124

03CF ... 03FF

975 ... 1023

GSM EXTENDED
REDUCED
"EXT900"

0000

0000 ... 007C

0 ... 124

03CF ... 03FF

975 ... 1023

DCS 1800
"DCS1800"

0200 ... 0375

512 ... 885

PCS 1900

0200 ... 032A

512 ... 810

GSM-R

03BB ... 03CE

955 ... 974

GSM-DCS

0000 ... 007C

0 ... 124

03CF ... 03FF

975 ... 1023

0200 ... 0375

512 ... 885

GSM850

0080 ... 00FB

128 ... 251

GSM850-PCS

0080 ... 00FB

128 ... 251

0200 ... 032A

512 ... 810

0080 ... 00FB

128 ... 251

0200 ... 0375

512 ... 885

GSM850-DCS

674

Id:0900d8058051e910

A50016-G5100-B333-04-7619

BS-4x / 82 II / 240 / 241 / 240XL commands

Changing or setting this attribute for a TRX means a temporary loss


of service for the TRX.
Changing this attribute for a CHAN is allowed only if there is no frequency hopping (i.e. attribute btsIsHopping = FALSE).
Validity Range
0 to 64 items of
0 - 1023
Default Value
octet #2 = 0 (only for aRFCNList related to "CHAN")
Contained in the following commands:
GET CHAN

MOEC
memberOfEmergencyConfig
The attribute memberOfEmergencyConfiguration specifies whether a TRX should still
operate for a given time (emergencyTimer1) if a "battery backup operation" (due to
"mains breakdown") occurs. If an emergency because of overtemperature occurs, this
attribute specifies a TRX which is not powered off immediately.
If this feature is wanted the value TRUE should be used at least for the BCCH TRX. If
FALSE is used for the BCCH TRX and TRUE is used for another TRX in the cell a BCCH
reconfiguration would be triggered if a "battery backup operation" (due to "mains breakdown") or overtemperature occurs.
Note:
The switch to emergency configuration or zero configuration in case of overtemperature
only depends on the temperature itself (two different values for emergency and zero
configuration) and doesn't depend on the emergencyTimer1/2.
Validity Range
TRUE
FALSE
Default Value
TRUE
Contained in the following commands:
GET TRX

MONPRT
monitoringPort
This attribute defines the port which is used for Abis traffic monitoring on the ETHCON
module.

A50016-G5100-B333-04-7619

Id:0900d8058051e910

675

BS-4x / 82 II / 240 / 241 / 240XL commands

The attribute enables mirroring of packets for the configured monitoringPort. The port
number corresponds to the ETHPORT instance number. Port mirroring can be enabled
for maximum one port.
The system does not check if the referenced port is already created.
Validity Range
none
port0
port1
port2
port3
coba
Default Value
none
Contained in the following commands:
GET ETHCON, SET ETHCON

MORT
MOT
This Attribute describes an object instance. The MOT attribute defines the HW-MO that
will have its internal resources tested.
Below are reported some detailed information about the validity range.
For:

BS240,

676

BS40, BS41 BS40II

BS82II

BS240SR,

BS241,

BS241SR,

BS240XL

BS240XLS
R

ACDCP

ACT

BATTERY

BCOM

COBA #)

COSA

CU

DIDCTMA

DILNA

Id:0900d8058051e910

A50016-G5100-B333-04-7619

BS-4x / 82 II / 240 / 241 / 240XL commands

DUDCTMA

DULNA

DUVSWR

F6DCTMA

F6LNA

F6TNFP

F6VSWRP

FANP *)

FCUMAIN

FCUTR

FTNFP

LMU

TMA *)

*) no processor #) COBA #0 only possible via local LMT on


phase 2
Validity Range
Pathname
Default Value
None.
Contained in the following commands:
GET BTSETEST, PERFTEST BTSEP, STOPTEST BTSEP

MPHERR
maxPhaseError(microsec)
This attribute specifies the desired maximum phase deviation of the base clock on the
COBA in respect to the GPS clock. If the current phase deviation exceeds this desired
maximum value an alarm is issued and the attribute clockAccuracy is set to the reduced
accuracy level 'high'. This attribute is only meaningful if the attribute syncSource is set
to 'extGPS' and the attribute enableInterSiteSync is set to 'TRUE'.
Validity Range
1.5 - 15.0
Default Value
1.5

A50016-G5100-B333-04-7619

Id:0900d8058051e910

677

BS-4x / 82 II / 240 / 241 / 240XL commands

Contained in the following commands:


GET SYNCBTSE, SET SYNCBTSE

MPTSLXX
mappingTSLXX
This attribute describes to which "time slot" of the specified Bport the TS xx of the Bport
related to the given XConnect instance is to be mapped; e. g. 'mappingTSL02' of
XConnect 0 describes the mapping of time slot 2 of BPort 0 (which corresponds to
XConnect 0) to a time slot (targetTSL) of a BPort instance (targetBPort). If the 'target
BPort' value is equal to the value of the XConnect instance this means that a "remapping" between the time slot position on the Abis line and the BTSE internal position is
done- this is allowed only in LMT phase 2. The purpose for this "remapping" usually is
to have the traffic data and signalling data in the BTSE at the same positions as at the
PCM lines directly connected to the BSC (and as indicated in the attributes abisChannel
and lapdChannel)- this is needed e.g. if there is a sequence of several PCM lines
between BSC and BTSE involving multidrop/loop and cross connect configurations.
In case of PCM24 only mappingTSL01..mappingTSL24 are meaningful.
XConnect instance 0 is related to BPORT instance 0
XConnect instance 1 is related to BPORT instance 1
XConnect instance 2 is related to BPORT instance 2
XConnect instance 3 is related to BPORT instance 3
XConnect instance 4 is related to BPORT instance 4
XConnect instance 5 is related to BPORT instance 5
XConnect instance 6 is related to BPORT instance 6
XConnect instance 7 is related to BPORT instance 7
note on targetTSL validity range:
- targetTSL : 0 ... 24 for time slot in 1,5 Mb/s link
- targetTSL : 0 ... 31 for time slot in 2 Mb/s link
targetBport = 0 and targetTSL = 0 mean 'no mapping'
Validity Range
targetBport

0-7

targetTSL

0 - 31

Default Value
targetBport

targetTSL

Contained in the following commands:


CREATE XCONNECT, GET XCONNECT, SET XCONNECT

678

Id:0900d8058051e910

A50016-G5100-B333-04-7619

BS-4x / 82 II / 240 / 241 / 240XL commands

MRSYNCT
maxResyncTime(min)
This attribute allows the operator to adjust the maximum re-synchronization time to
reach the desired phase accuracy defined with the attribute maxPhaseError. If the estimated re-synchronization time exceeds this value an alarm is issued, which informs the
operator that a manual re-synchronization should be considered. The time can be
adjusted between 0 and 24 hours (i.e. 0-1440 minutes). This attribute is only meaningful
if the attribute syncSource is set to 'extGPS' and the attribute enableInterSiteSync is set
to 'TRUE'.
Validity Range
0 - 1440
Default Value
180
Contained in the following commands:
GET SYNCBTSE, SET SYNCBTSE

MSTXPMAX
mSTxPwrMax(*dBm mapped)
This attribute indicates the maximum power level an MS may use in the serving cell. In
case of GSMDCS, GSM850-PCS and GSM850-DCS mixed cells the attribute represents the maximum power level a MS may use in the band to which the BCCH belongs.
Below are listed some detailed validity range values
GSM / GSM-R:
39 dBm
37 dBm
:
33 dBm, Default Value
:
15 dBm
13 dBm
DCS 1800:
30 dBm, Default Value
28 dBm
:
02 dBm
00 dBm
PCS 1900:

A50016-G5100-B333-04-7619

Id:0900d8058051e910

679

BS-4x / 82 II / 240 / 241 / 240XL commands

30 dBm, Default Value


28 dBm
:
02 dBm
00 dBm
33 dBm
32 dBm
Validity Range
0 - 31
Default Value
None.
Contained in the following commands:
GET BTS

MSTXPMAXC
mSTxPwrMaxCompl
This attribute is meaningful only in case of GSM-DCS, GSM850-PCS and GSM850DCS mixed cells and represents the maximum power level a MS can use in the band of
the serving cell to which the BCCH doesn't belong. A change of the attribute becomes
effective with the next call.
BCCH is in the DCS or PCS band - the MS can use the specified value
for the maximum power in the GSM band (i.e. in the band complementary
to the BCCH band)
39 dBm
37 dBm
:
33 dBm, Default Value
:
15 dBm
13 dBm
BCCH is in the GSM band - the MS can use the specified value for the
maximum power in the DCS band (i.e. in the band complementary to
the BCCH band)
30 dBm, Default Value
28 dBm
:
02 dBm

680

Id:0900d8058051e910

A50016-G5100-B333-04-7619

BS-4x / 82 II / 240 / 241 / 240XL commands

00 dBm
BCCH is in the GSM band - the MS can use the specified value for the
maximum power in the PCS band (i.e. in the band complementary to
the BCCH band)
30 dBm, Default Value
28 dBm
:
02 dBm
00 dBm
33 dBm
32 dBm
Validity Range
0 - 31
Default Value
None.
Contained in the following commands:
GET BTS

MTLT
mechanicalTilt(degree*10)
Attribute data provided by the TMA.
Validity Range
0 - 65535
<NULL>
Default Value
None.
Contained in the following commands:
GET TMA

MTYP
mediaType
This attribute indicates the type of the physical medium used for the given instance of
Ethernet port.
Validity Range
electrical

A50016-G5100-B333-04-7619

Id:0900d8058051e910

681

BS-4x / 82 II / 240 / 241 / 240XL commands

optical
<NULL>
Default Value
None.
Contained in the following commands:
GET ETHPORT

682

Id:0900d8058051e910

A50016-G5100-B333-04-7619

BS-4x / 82 II / 240 / 241 / 240XL commands

n
NEPTTREP
notDataRepCount
This attribute determines the number of repetitions for the not_data message per cell.
Up to 3 repetitions can be configured. The repetition rate is constant 200 ms.
Validity Range
0-3
Default Value
None.
Contained in the following commands:
GET BTS

NTWTYPC
networkTypeCompensation
The attribute allows to choose between different PDV compensation parameter sets
which are optimized to certain network behaviors.
Validity Range
0 - 255
Default Value
0
Contained in the following commands:
CREATE CESTUNNEL, GET CESTUNNEL, SET CESTUNNEL

NTWTYPE
networkType
This attribute defines the type of network (in terms of frequency band(s)) the BTS is
working in. Further more it indicates the type of a possible complementary frequency
band when handling Dual Band Mobiles.
Below are listed some details about the attribute validity range:
GSMDCS:
GSM 900
DCS 900
GSM EXTENDED

A50016-G5100-B333-04-7619

Id:0900d8058024e3aa

683

BS-4x / 82 II / 240 / 241 / 240XL commands

GMS EXTENDED REDUCED


GMS-DCS
GSMPCS:
GSM 900
GSM EXTENDED
GMS EXTENDED REDUCED
PCS 1900
GSMR:
GSM-R
.
.
GSM850PCS:
PCS 1900
GSM850
GSM850PCS
GSM850DCS:
DCS 1800
GSM850
GSM850DCS
GSMRAIL PUB:
GSM 900
DCS 1800
GSM EXTENDED
GMS EXTENDED REDUCED
GSM-R
GSM-DCS

Validity Range
GSMDCS
GSMPCS
GSMR
GSM850PCS
GSM850DCS

684

Id:0900d8058024e3aa

A50016-G5100-B333-04-7619

BS-4x / 82 II / 240 / 241 / 240XL commands

Default Value
None.
Contained in the following commands:
GET BTS

NY1
ny1
This attribute indicates the maximum number of repetitions of the PHYSICAL INFORMATION message on the radio interface. This message is sent by the BTS to the MS
during a handover procedure between two not synchronised cells, in order to establish
a physical channel connection on the new cell. If the maximum number of repetitions is
reached, the newly allocated channels are released and the context related to the
handover is abandoned. ny1 is a binary presentation of maximum number of repetitions
of PHYSICAL INFORMATION.
Note: (ny1) * (BTS Air Timer t3105) must be greater than the maximum Um Layer 2
response time.
Validity Range
1 - 254
Default Value
30
Contained in the following commands:
GET BTS

NY2
ny2
As a result of an Uplink Access of a mobile station the network grants the uplink to the
mobile station by sending a VGCS UPLINK GRANT message periodically. ny2 is the
counter value which defines the number of repetitions of sending the message.
Validity Range
1 - 254
Default Value
20
Contained in the following commands:
GET BTS

A50016-G5100-B333-04-7619

Id:0900d8058024e3aa

685

BS-4x / 82 II / 240 / 241 / 240XL commands

o
OMLAPDRT
omLapdRelTimer(sec)
At the detection time of the Abis link failure (which may happen at different times in
BTSE and BSC) the BTSE starts the timer omLAPDRelTimer and the BSC starts the
timer shortLAPDIntTimer. If the timer omLAPDRelTimer expires, the BTSE blocks the
call processing. After that the BTSE forces the BSC (via a RestartSendingEventReports-NACK message) to perform a complete Abis alignment. If none of the two
timers expires, the BSC performs a 'Short Abis alignment'. The default value of omLAPDRelTimer should be kept greater than the default value of the attribute shortLAPDIntTimer.
The validity range step size is 1 second.
Validity Range
3 - 300
Default Value
30 seconds
Contained in the following commands:
GET BTSM NOSWL

OST
operationalState
This attribute defines whether or not the resource is physically installed and working.
Validity Range
DISABLED
ENABLED
Default Value
DISABLED for Functional Objects
Contained in the following commands:
GET ACDCP, GET ACT, GET BATTERY, GET BCOM, GET BPORT, GET BTS,
GET BTSEP NOSWL, GET BTSM NOSWL, GET CESPW, GET CESTUNNEL, GET
CHAN, GET COBA, GET COBAETHINTF, GET COSA, GET CU, GET DIDCTMA,
GET DILNA, GET DUAMCO, GET DUDCTMA, GET DULNA, GET DUVSWR, GET
ENVABTSE, GET ETHCON, GET ETHPORT, GET F6DCTMA, GET F6LNA, GET
F6TNFP, GET F6VSWRP, GET FANP, GET FCUMAIN, GET FCUTR, GET FTNFP,
GET FVSWRP, GET LAPDLE, GET RACK, GET SYNCBTSE, GET TMA, GET TRX,
GET XCONNECT

686

Id:0900d8058024e3bf

A50016-G5100-B333-04-7619

BS-4x / 82 II / 240 / 241 / 240XL commands

OUTPUTPR
outputPowerReduction
The attribute specifies if and how the maximum output power of the carrier unit / FlexCU
carrier has to be reduced because of the setting of the BTS attribute 'carrierUnitConfiguration.
Attribute valid only for CU and FlexCU.
Validity Range
db0
db1
...
db4
Default Value
None.
Contained in the following commands:
GET CU, GET FCUTR

OVERWRITE
Overwrite
This attribute specifies whether the existing BTS-SW on the BSC
hard disk will be overwritten (YES) or not (NO) (UPLBTSLOG).
This attribute specifies whether the existing file containing the Alarm
Buffer SW will be overwritten (YES) or not (NO) (UPLBTSLOG).
This attribute specifies whether the existing IDT file will be overwritten
(YES) or not (NO) (UPLLIDF).
Validity Range
NO
YES
Default Value
None.
Contained in the following commands:
DNLALLEXE SOFTWARE-MANAGEMENT, UPLBTSLOG SOFTWARE-MANAGEMENT, UPLLIDF REMINV

OVPTINS
ovptInstalled

A50016-G5100-B333-04-7619

Id:0900d8058024e3bf

687

BS-4x / 82 II / 240 / 241 / 240XL commands

This attribute indicates whether an OVPT board is installed or not. It can be set only in
LMT phase 2. The attribute is used to adapt the pulse mask according to the recommendations.
Validity Range
TRUE
FALSE
Default Value
TRUE
Contained in the following commands:
GET BTSEP NOSWL, SET BTSEP

688

Id:0900d8058024e3bf

A50016-G5100-B333-04-7619

BS-4x / 82 II / 240 / 241 / 240XL commands

p
PCCCHLDI
periodCcchLoadIndication(sec)
This attribute indicates the frequency with which the CCCH load indication is sent to the
BSC. This attribute is also used to enable the Paging Overload Handling.
The value 0 has two meanings:
- the CCCH Load Indication message is sent only once, every time an overload occurs,
with no repetition (frequency = 0)
- the feature Paging Overload Handling is not enabled

Validity Range
0 - 255
Default Value
255 seconds
Contained in the following commands:
GET BTS

PEERADDR
peerAddress
Peer IP address of the Circuit Emulation Service Tunnel.The address is input in the
usual IPv4 format. The object must be locked before modifying the address via the SET
command.
Validity Range
7..15 characters string
Default Value
None.
Contained in the following commands:
CREATE CESTUNNEL, GET CESTUNNEL, SET CESTUNNEL

PEERUDPPORT
peerUdpPort
Peer UDP port number of the CESPW instance. It is recommended to use identical port
numbers for the local and the peer UDP port. The object must be locked before modifying the port number via the SET command.

A50016-G5100-B333-04-7619

Id:0900d8058024fcdc

689

BS-4x / 82 II / 240 / 241 / 240XL commands

Validity Range
49152 - 65535
Default Value
None.
Contained in the following commands:
CREATE CESPW, GET CESPW, SET CESPW

PKTLAT
packetizationLatency
The attribute defines the number of frames which are contained in the payload of each
UDP packet.
The latency is expressed in micro seconds. Every 125 sec correspond to 1 TDM
frame in the payload. A lower value means a lower delay but a bigger protocol overhead.
The object must be locked before modifying the latency value via SET command.
Validity Range
m125
m500
m1000
m2000
m3000
m4000
m5000
Default Value
m1000
Contained in the following commands:
CREATE CESPW, GET CESPW, SET CESPW

PNGF
pingFrequency
The attribute is only meaningful if the ping delay measurement is activated via the PM
scanner SCANBTSM - RNDTDELBTS. It defines how many ping request packets are
sent per minute.
SCANBTSM provides only ping delay measurement results if the attribute is set to a
value greater than 0.
Validity Range
0 - 120

690

Id:0900d8058024fcdc

A50016-G5100-B333-04-7619

BS-4x / 82 II / 240 / 241 / 240XL commands

Default Value
0
Contained in the following commands:
CREATE CESTUNNEL, GET CESTUNNEL, SET CESTUNNEL

PNGPKT
pingPacketSize
The attribute is only meaningful if the ping delay measurement is activated via the PM
scanner SCANBTSM - RNDTDELBTS. It defines the size of a ping request packet. The
value small corresponds to the default packet size of the ICMP ping request. Value
traffic corresponds to the maximum packet size within the pseudo wires of the tunnel.
Validity Range
SMALL
TRAFFIC
Default Value
TRAFFIC
Contained in the following commands:
CREATE CESTUNNEL, GET CESTUNNEL, SET CESTUNNEL

PNOFACCH
periodNotificationFACCH(sec)
The attribute defines the period (repetition rate) for the FACCH notification for a given
ASCI call.
A change of the attribute becomes effective at expiration of the current time period,
latest after the time given by "periodNotificationFACCH".
Validity Range
1.0 - 5.0
Default Value
2.5 seconds
Contained in the following commands:
GET BTS

PRDINF
productInfo(prodNbr_SN_HwVer_SwVer)

A50016-G5100-B333-04-7619

Id:0900d8058024fcdc

691

BS-4x / 82 II / 240 / 241 / 240XL commands

The attribute shows product specific information of the TMA if HDLC signaling is used
and information is provided by the TMA. It is represented by a single string, consisting
of four parts, separated by a couple of defined delimiters:

delimiter1 ;

delimiter2 (a white space)

This attribute will be retrieved by own command get TMA prodInfo.


Validity Range
0..77 characters string
Default Value
None.
Contained in the following commands:
GET TMA, GET TMA PRODUCTINFO

PRDIRECT
preferredDirection
The attribute indicates whether the RX downlink information is gained from the related
BPORT or not. In a loop configuration the preferred direction is changed, if e.g. the Bit
Error Rate is greater than a certain threshold or if the link fails.
'TRUE' means that the RX data at the given BPORT instance is used as input data.
'FALSE' means that the RX data at the given BPORT instance is not used as input data.
The attribute is meaningful only in a loop configuration. If a GET is done in other configurations the length will be set to 0.
Validity Range
TRUE
FALSE
<NULL>
Default Value
None.
Contained in the following commands:
GET BPORT

PRS
proceduralStatus
This attribute is contained in all equipment related managed objects. It indicates whether
the assigned HW board performs an initialization procedure. For non processor HW
boards, the proceduralStatus is always NULL.
This attribute is readable by the operator but is not contained in the "Changed State
Event Report" notification.

692

Id:0900d8058024fcdc

A50016-G5100-B333-04-7619

BS-4x / 82 II / 240 / 241 / 240XL commands

Validity Range
NULL
initializing
Default Value
NULL
Contained in the following commands:
GET ACDCP, GET ACT, GET BATTERY, GET BCOM, GET BPORT, GET BTSEP
NOSWL, GET CESPW, GET CESTUNNEL, GET COBA, GET COBAETHINTF, GET
COSA, GET CU, GET DIDCTMA, GET DILNA, GET DUAMCO, GET DUDCTMA,
GET DULNA, GET DUVSWR, GET ENVABTSE, GET ETHCON, GET ETHPORT,
GET F6DCTMA, GET F6LNA, GET F6TNFP, GET F6VSWRP, GET FANP, GET
FCUMAIN, GET FCUTR, GET FTNFP, GET FVSWRP, GET LAPDLE, GET RACK,
GET SYNCBTSE, GET TMA, GET XCONNECT

PSTAT
portStatus
This attribute provides the result of the auto negotiation procedure. If auto negotiation is
disabled the current setting of the port is shown.
Validity Range
speed

speed100M
speed1000M

duplexMode

disabled
enabled

flowControl

disabled
enabled

Default Value
None.
Contained in the following commands:
GET ETHPORT

PUSG
portUsage
This attribute determines usage of the Ethernet port at BTSE. Only one ETHPORT
instance can be set to BSClink. From one BTS only one port can be configured as multidropLink. If the base stations are synchronized via Abis it is recommended to limit the
number of cascaded stations to 5.
Validity Range
bscLink

A50016-G5100-B333-04-7619

Id:0900d8058024fcdc

693

BS-4x / 82 II / 240 / 241 / 240XL commands

multidropLink
Default Value
None.
Contained in the following commands:
CREATE ETHPORT, GET ETHPORT, SET ETHPORT

PWNAME
pwName
This attribute specifies optional symbolic name of the pseudo wire, the same name
should be configured at the peer side. The name has to be unique within all CESPW
instances on given host.
Validity Range
1..80 characters string
Default Value
None.
Contained in the following commands:
CREATE CESPW, GET CESPW, SET CESPW

PWROUT
powerOutputThresholds
This attribute defines the three power output thresholds:
-

Output Power Fault Threshold: defines the minimal output


power level "transmitter-fault", which results in generating an
alarm.

Reduced Output Power Threshold: defines the power level,


when an alarm (warning) is generated (Pout alm red) due to
less output power.

Excessive Output Power Threshold: defines the power level,


when an alarm is generated (Pout alm fault) due to too much
power level at the output of the power amplifier.

The attribute value is indicated in dB.


The letter "m" before the value range values, means minus
Validity Range
oPwrFaultThreshold m10db
m8db

694

Id:0900d8058024fcdc

A50016-G5100-B333-04-7619

BS-4x / 82 II / 240 / 241 / 240XL commands

redOutPwrThreshold

m10db
m8db
m6db
m4db

excesOutPwrThresh db3
db5
Default Value
m10dB = -10dB
m6db = - 6dB
db5 = 5dB
Contained in the following commands:
GET BTS

PWRRED
txPwrMaxReduction(*-2dB)
This attribute specifies the number of 2dB steps the TRX should be reduced from the
maximum transmit power, for tuning the cell coverage. The resulting attenuated transmit
power is the maximum nominal power Pn.
(values from 0 dB to -12 dB, with step size - 2 dB)
Validity Range
0-9
Default Value
None.
Contained in the following commands:
GET TRX

A50016-G5100-B333-04-7619

Id:0900d8058024fcdc

695

BS-4x / 82 II / 240 / 241 / 240XL commands

r
RACHBT
rachBusyThreshold(dBm)
This attribute defines a threshold for the received signal level concerning both:
-

RACH access bursts

intercell HO access bursts.

A signal level exceeding this threshold is interpreted as a busy RACH


respective as a valid burst due to an intercell HO.
Validity Range
<ANY>
Default Value
109
Contained in the following commands:
GET BTS

RACHLAS
rachLoadAveragingSlots
This attribute defines the number of RACH bursts over which RACH measurements are
performed.
Validity Range
102 - 65535
Default Value
204 = 4 CCCH multiframes
Contained in the following commands:
GET BTS

RADIOMG
radioMeasGran
This is an attribute of the TRX and specifies the granularity (multiples of 480 ms) in
which the radio measurements have to be transmitted on the Abis interface in case they
are enabled.
The attribute is indicated in SACCH multiframes

696

Id:0900d8058051e912

A50016-G5100-B333-04-7619

BS-4x / 82 II / 240 / 241 / 240XL commands

Validity Range
1 - 254
Default Value
254 in SACCH multiframe
Contained in the following commands:
GET TRX

RADIOMR
radioMeasRep
This is an attribute of the TRX and specifies whether the radio measurements have to be transmitted on the Abis interface.
Notes:
-

A consequence of the value 'disabled' is that no 'Measurement result' messages are sent to the BSC.

Special care has to be applied if the attribute is set to "ON" for


several TRXs: the appropriate Abis signalling capacity must
be provided by creating a sufficient number of LAPDLE
instances each with a full 64 KBit/s timeslot. If this prerequisite
is not fulfilled (e.g. just 1 LAPDLE and 11 TRXs with full and
half rate are fully exploited - FEKAT CR2826) the Call Failure
Rate will increase (increased delay times in the BTSE LAPD
queues due to the huge amount of measurement result
messages lead to more CHANNEL REQUIRED messages
because of a too late Immediate Assignment command etc.
etc.). This is especially critical if RADIOMG is set to 1 (corresponding to 480 ms).

(ON = enabled)
Validity Range
OFF
ON
Default Value
OFF (disabled)
Contained in the following commands:
GET TRX

RELEQUIPOBJ
relatedEquipObjects

A50016-G5100-B333-04-7619

Id:0900d8058051e912

697

BS-4x / 82 II / 240 / 241 / 240XL commands

This attribute represents the relationships between a specific FMO


instance and none, one or several HMO instances. The HMO
instances in this list offers their services to the given FMO instance.
This attribute is only allowed for BTSM, BTS, TRX and CHANNEL.

FMO

maximal number of
related HMOs

N (decimal)

BTS

BTSM

CHAN

TRX

30

122

Validity Range
0 to 47 items of
Pathname
Default Value
None.
Contained in the following commands:
GET BTS, GET BTSM NOSWL, GET CHAN, GETRELATIONSHIP TRX

RELFUNCOBJ
relatedFuncObjects
This attribute represents the relationships between a specific HMO
instance and none, one or several FMO instances. The FMO
instances in this list make use of the services of the given HMO
instance. This attribute is allowed for each HMO instance of the actual
hardware variant. Currently only BTSM and TRX are contained in the
list.
Since the maximal number of related FMO instances in the list
depends on the special type of HMO, the following list shows the realistic values for the each HMO that may contain related FMO
instances. The table shows for each HMO the maximal number of
FMO instances and the maximum number of octets of the attribute
including the attribute identifier and attribute length field.

698

HMO

maximal number of
related FMOs

N (decimal)

BPORT

BTSE

Id:0900d8058051e912

A50016-G5100-B333-04-7619

BS-4x / 82 II / 240 / 241 / 240XL commands

CESPW

CESTUNNEL

COBAETHINF

ENVABTSE

LAPDLE

RACK

SYNCBTSE

48

194

XCONNECT

HMO

maximal number of
related FMOs

N (decimal)

ACDCP

ACT

BATTERY

BCOM

12 (see note 1)

50

COBA

48

194

COSA

24 (see note 2)

98

CU

DIDCTMA

24

98

DILNA

24

98

DUAMCO

DUDCTMA

24

98

DULNA

24

98

DUVSWR

24

98

ETHCON

F6DCTMA

12 (see note 3)

50

F6LNA

12 (see note 3)

50

F6TNFP

F6VSWRP

26

FANP

FCUMAIN

10

FCUTR

FTNFP

FVSWRP

34

LMU

SDULNA

34

SDUSEC

18

A50016-G5100-B333-04-7619

Id:0900d8058051e912

699

BS-4x / 82 II / 240 / 241 / 240XL commands

SDUSUBSEC

34

SDUTXSW

TMA

24

98

Note 1: only for BS288/BS289 (for BS240XS:6 FMOs)


Note 2: COSA old (if enableFcuSupport = TRUE) and COSA new only
can handle up to 12 FCU (24 TRX)
Note 3: If using a double "cross-cascading" FICOM6 configuration
with SDTMA
Validity Range
0 to 48 items of
Pathname
Default Value
None.
Contained in the following commands:
GET ACDCP, GET ACT, GET BATTERY, GET BCOM, GET BPORT, GET BTSEP
NOSWL, GET CESPW, GET CESTUNNEL, GET COBA, GET COBAETHINTF, GET
COSA, GET CU, GET DIDCTMA, GET DILNA, GET DUAMCO, GET DUDCTMA,
GET DULNA, GET DUVSWR, GET ENVABTSE, GET ETHCON, GET ETHPORT,
GET F6DCTMA, GET F6LNA, GET F6TNFP, GET F6VSWRP, GET FANP, GET
FCUMAIN, GET FCUTR, GET FTNFP, GET FVSWRP, GET LAPDLE, GET RACK,
GET SYNCBTSE, GET TMA, GET XCONNECT, GETRELATIONSHIP BCOM, GETRELATIONSHIP COBA

REPTYP
reportType
This parameter is used to indicate to the mobile station to use the ENHANCED MEASUREMENT REPORT or MEASUREMENT REPORT messages for reporting, and it
can assume two values:
- NORMAL: the MS uses the MEASUREMENT REPORT message for reporting
- ENHANCED: the MS uses the ENHANCED MEASUREMENT REPORT message for
reporting if at least one BSIC (Base Station Identity Code) is allocated to each frequency
of the BA (BCCH Allocation) list . Otherwise, the MEASUREMENT REPORT message
is used.
Validity Range
ENHANCED

700

Id:0900d8058051e912

A50016-G5100-B333-04-7619

BS-4x / 82 II / 240 / 241 / 240XL commands

NORMAL
ENHANCED_ONLY_FOR_
R43G_MS
Default Value
None.
Contained in the following commands:
GET BTS

RFRSINDP
rfResourceIndicationPeriod
This attribute indicates the sending rate of the signalling message RF RES IND to the
BSC.
The attribute is indicated in unit of SACCH multiframes
Validity Range
1 - 254
Default Value
60 in unit of SACCH multiframe
Contained in the following commands:
GET BTS

RSACCHRXLDL
repSacchRxLevDL
This attribute is used to define, on a per cell basis, the threshold for RXLEV_DL_SUB
used in the decision algorithm for activating R-SACCH in DL and UL for MS with
Repeated SACCH Capability, i.e. R-ACCH_CAP = 1.
Validity Range
0 - 25
Default Value
None.
Contained in the following commands:
GET BTS

RSACCHRXLUL
repSacchRxLevUL

A50016-G5100-B333-04-7619

Id:0900d8058051e912

701

BS-4x / 82 II / 240 / 241 / 240XL commands

This attribute is used to define, on a per cell basis, the threshold for RXLEV_UL_SUB
used in the decision algorithm for activating R-SACCH in DL and UL for MS with
Repeated SACCH Capability, i.e. R-ACCH_CAP = 1.
Validity Range
0 - 25
Default Value
None.
Contained in the following commands:
GET BTS

RSACCHTODL
repSacchTimeOutDL
This attribute is used to define, on a per cell basis, the threshold for deactivation of RSACCH mode in the decision algorithm for R-SACCH in DL for MS with Repeated
SACCH Capability, i.e. RACCH_CAP = 1.
Validity Range
0 - 10
Default Value
None.
Contained in the following commands:
GET BTS

RSACCHTOUL
repSacchTimeOutUL
This attribute is used to define, on a per cell basis, the threshold for deactivation of RSACCH mode in the decision algorithm for R-SACCH in UL for MS with Repeated
SACCH Capability, i.e. RACCH_CAP = 1.
Validity Range
0 - 10
Default Value
None.
Contained in the following commands:
GET BTS

RXBMAXF
rxBandMaxFreq(kHz*100)

702

Id:0900d8058051e912

A50016-G5100-B333-04-7619

BS-4x / 82 II / 240 / 241 / 240XL commands

Attribute data provided by the TMA.


Validity Range
0 - 65535
<NULL>
Default Value
None.
Contained in the following commands:
GET TMA

RXBMINF
rxBandMinFreq(kHz*100)
Attribute data provided by the TMA.
Validity Range
0 - 65535
<NULL>
Default Value
None.
Contained in the following commands:
GET TMA

RXDIVSV
enableRxDiversitySupervision
The attribute enableRxDiversitySupervision of the object 'BTSE' indicates whether the
supervision of the RX levels and the signal to noise ratio of both receiver branches is
enabled or disabled. A prerequisite is that diversity is configured and that a TCH or
SDCCH is on at least 2 time slots of the TRX. Due to the supervision failure event reports
for the TPU / CU related to a TRX may be sent.
Validity Range
disabled
enabled
Default Value
disabled
Contained in the following commands:
GET BTSEP NOSWL, SET BTSEP

A50016-G5100-B333-04-7619

Id:0900d8058051e912

703

BS-4x / 82 II / 240 / 241 / 240XL commands

RXLEVADJ
rxLevAdjust(dB)
This attribute specifies the value needed to adjust the RXLEV value of both receiver
branches ("N" and "D") of the TPU, CU and of the FCUMAIN.
The attribute has no functionality in case a FCUMAIN is wired to a SDUAMCO.
(values from -24 dB to +23 dB)
Validity Range
adjustValue

-24.0 - 24.0

adjustDivValue

-24.0 - 24.0

Default Value
adjustValue

0.0

adjustDivValue

0.0

Contained in the following commands:


CREATE CU, CREATE FCUMAIN, GET CU, GET FCUMAIN, SET CU, SET
FCUMAIN

RXLEVADJN1D1
rxLevAdjustN1D1(dB)
This attribute specifies the value needed to adjust the RXLEV value of the additional
receiver branches "Rx C / N1" and "Rx D / D1" of the FCUMAIN.
The attribute has no functionality in case a FCUMAIN is wired to a SDUAMCO).
Validity Range
adjustValueN1

-24.0 - 24.0

adjustDivValueD1

-24.0 - 24.0

Default Value
adjustValueN1

0.0

adjustDivValueD1

0.0

Contained in the following commands:


CREATE FCUMAIN, GET FCUMAIN, SET FCUMAIN

RXSIGLEVADJ
rxSigLevAdjust
The attribute specifies the signal level adjust values which shall be applied to the receive
paths of transceivers using the same frequency band as the BCCH transceiver.

704

Id:0900d8058051e912

A50016-G5100-B333-04-7619

BS-4x / 82 II / 240 / 241 / 240XL commands

Validity Range
<ANY>
Default Value
None.
Contained in the following commands:
GET BTS

RXSIGLEVADJC
rxSigLevAdjustCompl
The attribute specifies the signal level adjust values which shall be applied to the
transmit paths oftransceivers using the complementary frequency band. The value is
only meaningful in case of a multiband cell.
Validity Range
<ANY>
Default Value
None.
Contained in the following commands:
GET BTS

RXSWCURSET
rxSwitchCurrentSetting
Usually the content of this attribute is identical to the value of the attribute rxSwitchReqSetting. A deviation is possible e.g. in case of HW failures - in these cases the attribute
shows the real situation. The attribute has a meaning only if the value of the attribute
switchedBeamCapability has the value four_beams.
A change of the attribute value is sent by the BTSE via CAER to the BSC.
Validity Range
NULL
Default Value
None.
Contained in the following commands:
GET BTS

A50016-G5100-B333-04-7619

Id:0900d8058051e912

705

BS-4x / 82 II / 240 / 241 / 240XL commands

s
SALUNAME
salesUniqueName
The attribute contains an ASCII string with 11 characters which don't
contain a NUL character. The operator has always to enter 11 characters for the attribute. If the operator has not yet supplied a value for
the attribute but does a GET, the BTSE SW will return the 'default
value'. The attribute should be set by the operator before a upload of
the IDT is performed.
The attribute is also used during the Abis alignment for checking if the
right BTSE is connected to the Abis link.
Default Value: length = 1, octet 3 = 0
Validity Range
In commands GET BTSEP NOSWL:
1..11 characters string
In commands SET BTSEP:
11..11 characters string
Default Value
length = 1, octet 3 = 0
Contained in the following commands:
GET BTSEP NOSWL, SET BTSEP

SBPRT
syncBport
This attribute indicates the port which is currently used for synchronization. This information is specially useful in case of a PCM loop configuration.
Validity Range
<ANY>
Default Value
None.
Contained in the following commands:
GET SYNCBTSE

SBSCSLCV
superordinateBscSwLoadCurrentVersion

706

Id:0900d8058024ebff

A50016-G5100-B333-04-7619

BS-4x / 82 II / 240 / 241 / 240XL commands

This attribute contains the version number of the software load (26 bytes) that is currently running in the BSC.
Note: this attribute will not be stored in the BSC MIB master copy; it will be evaluated at
run-time by the system taking the information from the System Download SW Functional
area.
ASCII string: "SS-VV-RR-PR-LL-CL_yy-mm-dd" where
SS : System (02 = BSS)
VV : Version ("major version": e.g. 10 for BR10.x)
RR : Release ("minor version": e.g. 05 for BR9.5)
PR : Point Relase (usually 01, sometimes 02)
LL : Load Level (incremented at each CM load, starting form 00)
CL : Consolidation level (incremented at each crunch)
yy-mm-dd : production date (optional)
Validity Range
26..26 characters string
Default Value
None.
Contained in the following commands:
GET BTSM SWL

SCELLNO
secondCellNumber
This attribute allows to indicate a second cell number for the objects DILNA and DULNA.
Value <FF> means that a secondCellNumber is not used.
The second cell number allows sharing an antenna for receive diversity, i.e. it allows that
two cells with different MNC (Mobile Network Code) which cover the same area (e.g. the
same sector) at the BTSE site can share the same DUAMCO/FDUAMCO or IAMCO if
receive diversity is required. As a consequence a DULNA-, DILNA- or TMA instance
may belong to two cells.
The relation between a carrier unit and cell is derived from the TX wiring only, i.e. the
attribute cellNumber of the wired DUVSWR object determines the cell a CU/FCUTR
belongs to. The BTSE checks for each CU that one of the attributes cellNumber and secondCellNumber of all wired DULNA/DILNA objects matches with the attribute cellNumber of the wired DUVSWR.
It is strongly recommended to ensure for each CU/FCUTR that the attribute cellNumber
of one wired DULNA object matches with the cellNumber of the wired DUVSWR.
Validity Range
N_00
N_01
N_02

A50016-G5100-B333-04-7619

Id:0900d8058024ebff

707

BS-4x / 82 II / 240 / 241 / 240XL commands

N_03
N_04
N_05
N_06
N_07
N_08
N_09
N_10
N_11
NotUsed
Default Value
None.
Contained in the following commands:
CREATE DILNA, CREATE DULNA, CREATE F6LNA, GET DILNA, GET DULNA,
GET F6LNA, SET DILNA, SET DULNA, SET F6LNA

SCID
sectorId
Attribute data provided by the TMA.
Validity Range
0..32 characters string
Default Value
None.
Contained in the following commands:
GET TMA

SCLPRIOLST
serviceClassPrioList
Default settings of this attribute for CES service correspond to expedited forwarding:
service
Class

708

CES

Service
class to
whitch the
priority
settings
apply

Id:0900d8058024ebff

A50016-G5100-B333-04-7619

BS-4x / 82 II / 240 / 241 / 240XL commands

vlanPrio

The attribute
is not
relevant if
vlanid is set
to NULL

dscpClass

DSCP class
selector.
The value is
the decimal
representation of the
DSCP bits
0-2.

dscpDropPre

DSCP drop
precedence. The
value is the
decimal representation
of the DSCP
bits 3-5.

List of up to 8 service classes. Currently only the service class CES is supported. When
value CES is set for serviceClass all other attributes must not be set to default values.
Maximum one list entry is allowed for each service class.
Validity Range
1 to 8 items of
serviceClass

ces

vlanPrio

vPrio0
vPrio1
...
vPrio7

dscpClass

dCl0
dCl1
...
dCl7

dscpDropPre

dDP0
dDP1
...
dDP7

A50016-G5100-B333-04-7619

Id:0900d8058024ebff

709

BS-4x / 82 II / 240 / 241 / 240XL commands

Default Value
serviceClass

ces

vlanPrio

vPrio7

dscpClass

dCl5

dscpDropPre

dDP6

Contained in the following commands:


GET BTSEP NOSWL, SET BTSEP

SFPSERID
sfpSerialId
This attribute represents serial Id data if a SFP module is equipped.
The attribute is only meaningful for ports with SFP cages, i.e. it is not relevant for the
ETHPORT instances 0 and 1.
The structure of the octet string is compliant to the addresses 0 - 127 of the Serial ID
data at address A0.
Validity Range
0 to 128 items of
H#0 - H#ff
Default Value
None.
Contained in the following commands:
GET ETHPORT

SHLAPDIT
shortLapdIntTimer(sec)
The BTSE uses the value of this timer to calculate the value of timer T202 which is used
for the TEI assignment procedure.
This attribute is the timer used by the BSC in case of Abis link failure in order to discriminate between a "fast alignment" or a "full alignment". With the detection of the link failure
(which may happen at different times in BTSE and BSC) the BTSE starts the timer
'omLAPDRelTimer' and the BSC starts the timer 'shortLAPDIntTimer'. If any LAPD link
on any of the LAPDLE signalling timeslots is up again within a certain time (i.e. the timer
'shortLAPDIntTimer' in the BSC has not yet expired) the BSC may decide to perform the
fast alignment procedure.
At the detection time of the Abis link failure the BTSE starts the timer omLAPDRelTimer
and the BSC starts the timer shortLAPDIntTimer. If the timer omLAPDRelTimer expires,
the BTSE blocks the call processing. After that the BTSE forces the BSC (via a Restart
Sending Event Reports NACK message) to perform a complete Abis alignment. If none
of the two timers expires, the BSC performs a 'Short Abis alignment'.
(step size 1 second)

710

Id:0900d8058024ebff

A50016-G5100-B333-04-7619

BS-4x / 82 II / 240 / 241 / 240XL commands

Validity Range
3 - 20
Default Value
15 seconds
Contained in the following commands:
GET BTSM NOSWL

SLOTNO
slotNo
The attribute indicates the slot number of the COBA and COSA. Since the modelling of
the MO COBA is fixed (active COBA/COSA always COBA(0)/COSA(0), passive
COBA/COSA always COBA(1)/COSA(1)), this is the only way to find out the slot of the
active / passive COBA/COSA.
Validity Range
leftCOBA
rightCOBA
leftCOSA
rightCOSA
Default Value
None.
Contained in the following commands:
GET COBA, GET COSA

SRCDIR
sourceDir
The sourceDirectory indicates the directory containing the BTS-SW
to be downloaded (DNLALLEXE).
The sourceDirectory indicates the directory containing the BTSE nobRIU file to be downloaded (DNLIDFD).
Validity Range
1..80 characters string
Default Value
None.
Contained in the following commands:
DNLIDFD REMINV

A50016-G5100-B333-04-7619

Id:0900d8058024ebff

711

BS-4x / 82 II / 240 / 241 / 240XL commands

SRCPATH
srcpath
The sourceDirectory indicates the directory containing the BTS-SW to be downloaded
(DNLALLEXE).
Validity Range
1..92 characters string
Default Value
None.
Contained in the following commands:
DNLALLEXE SOFTWARE-MANAGEMENT

STATIME
startingTime
This attribute is only used together with btsIsHopping and can not be set by the operator.
Current Frame No is a binary presentation Frame Number Modulus 42432.
Note: startingTime is only used together with btsIsHopping.
Validity Range
0 - 65535
<NULL>
Default Value
None.
Contained in the following commands:
GET BTS TIMER

STDBYST
standbyStatus
The resource is not providing service but it is able to take over the role of the resource
to be backed-up without an initialization. The resource is providing service and it is
backing up another resource.
ColdStandBy:
The Carrier Unit is not providing service but is able to take over the active role.
ProvidingService:
The Carrier Unit is assigned to a TRX and is providing service.
NULL:

712

Id:0900d8058024ebff

A50016-G5100-B333-04-7619

BS-4x / 82 II / 240 / 241 / 240XL commands

The Carrier unit is not able to take over the active role because of failures or missing
configuration data.
Validity Range
Reserved
ColdStandBy
ProvidingService
NULL
Default Value
None.
Contained in the following commands:
GET COBA, GET COSA, GET CU, GET FCUTR, GET LAPDLE

SUBUNT
subUnitType
Attribute data provided by the TMA.
Validity Range
vswr
bypass
<NULL>
Default Value
None.
Contained in the following commands:
GET TMA

SWBCAPABILITY
switchedBeamCapability
This attribute reflects the capability of the BTSE hardware and software. A change of the
attribute value is sent by the BTSE via CAER to the BSC.
- unknown means the BTSE is not yet fully configured (e.g. SDUSEC not yet created)
- none means the BTSE hardware and/or software does not support switched beams.
- four_beams means the BTSE hardware and software supports 4 switched beams.

A50016-G5100-B333-04-7619

Id:0900d8058024ebff

713

BS-4x / 82 II / 240 / 241 / 240XL commands

Validity Range
none
Default Value
None.
Contained in the following commands:
GET BTS

SWBSERVSTATE
switchedBeamServState
The attribute indicates the current state of the switched beam functionality. A change of
the attribute value is sent by the BTSE via CAER to the BSC. The values have the following meaning:
NULL Initial value if BTSE is not aligned or default value if the BTSE type does not
support switched beams.
Validity Range
NULL
Default Value
None.
Contained in the following commands:
GET BTS

SWLCFID
swLoadCurrentFileId
This attribute contains the fileID (name of the SW load, 12 byte) of the software load that
is currently running in the BTSE. A SW load is the SW for the whole NE, that is able to
run on the processors of the NE at the same time. It consists of a certain number of SW
images, that are not shown to the operator for the BTSE.
Notes on validity range:
ASCII String: 'HScnvvss.SWL" (swLoad-header file), where:
cn Version part (network operator code)
01 = Ciphering A5.0 + A5.1 + A5.2
02 = Ciphering A5.0 + A5.2 12
03 = Ciphering A5.0 only
vv Version part (feature package code)
ss Version part (actual state)

714

Id:0900d8058024ebff

A50016-G5100-B333-04-7619

BS-4x / 82 II / 240 / 241 / 240XL commands

Validity Range
12..12 characters string
Default Value
None.
Contained in the following commands:
GET BTSM SWL

SWLCVER
swLoadCurrentFileVersion
This attribute contains the version number of the software load (26 bytes) that is currently running in the BTSE. Under normal operation conditions it is the same as the
version number of the swLoadIntended (SWLDINT). If the latter SW load is corrupted,
the swLoadCurrentVersion is identical to the version number of the swLoadSafety
(SWLDSAF) or the version number of the third SW load that is stored in the BTSE (the
dischargeable one). It is guaranteed that only SW loads are automatically started by the
BTSE, which have been executed on that BTSE before.
Notes on validity range:
ASCII String:cn-hh-vv-ii-ss-pp_yy-mm-dd, where:
cn Version part (network operator code)
01 = Ciphering A5.0 + A5.1 + A5.2
02 = Ciphering A5.0 + A5.2 12
03 = Ciphering A5.0 only
hh Version part (HW/SW compatibility code)
01 = BS20, BS21E, BS60, BS61E or BS22
04 = BS240, BS241, BS240XL, BS240SR, BS241SR,
BS240XLSR, BS40, BS40II, BS41, BS82II, BS82,
BS240XS, BS288
vv Version part (feature package code)
ii Version part (sub-feature package code)
00 = independent (e.g. loadable boot/test SW
01 = BS240, BS241, BS240XL, BS40, BS40II, BS41,
BS82II
05 = BS82
06 = BS240XS, BS288
ss Version part (actual state)
pp Patch version (usually 00)

A50016-G5100-B333-04-7619

Id:0900d8058024ebff

715

BS-4x / 82 II / 240 / 241 / 240XL commands

yy-mm-dd production date (optional)


Validity Range
26..26 characters string
Default Value
None.
Contained in the following commands:
GET BTSM SWL

SWLDINT
swLoadIntended
This attribute is divided into 2 parts and defines the file ID (=file name) and version
number of the SW load stored in the BTSE, that has been activated over the Abis- or Tinterface with the latest 'Activate SW' message. This SW load is automatically activated
from the BTSE firmware at power on time.
The file ID (= file ID for a SW load) and the version number () are supplied by the BTSE
after the 'Activate SW' message was sent. The value for both parts is 'not valid', if there
was no 'Activate SW' message before, or "swLoadCurrent", if the intended SW load is
corrupted.
Notes on validity range:
swLoadIntendedFileId: Coding according to swLoadCurrentFileId
Default Value: 0"filename.ext"
Octet #15 contains the ASCII character ":".
swLoadIntendedVersion: Coding according to swLoadCurrentVersion
Default Value: "cn-hh-vv-ii-ss-pp_yy-mm-dd"
The value 'not valid' for this attribute is indicated via '0' as byte 3.
Validity Range
39..39 characters string
Default Value
None.
Contained in the following commands:
GET BTSEP SWL

SWLDSAF
swLoadSafety

716

Id:0900d8058024ebff

A50016-G5100-B333-04-7619

BS-4x / 82 II / 240 / 241 / 240XL commands

This attribute is divided into 2 parts and describes the file ID (= file ID for a SW load) and
the version number () of the SW load stored in the BTSE, that is identified by the
operator at the OMC or LMT (via a 'Set Attribute' message at the Abis- or T- interface or
a M-SET service at the O-interface) as the most trusted SW load (in the sense of its
ability to handle the Abis-link to build up a connection to the BSC). It is used if the
swLoadIntended is damaged in some way. There is no alignment to one of the SW loads
stored on the BSC master database. It is even not necessary, that this SW load is stored
in the BSC master database. The identification of a SW load as the safety one is only
accepted by the BTSE, if the identified load has been activated and executed on this
BTSE before. It is recommended that an update of the attribute is performed in each
release and that the swLoad of the previous release is used as 'swLoadSafety'.
The value 'not valid' indicates that the safety SW load is corrupted or has not been identified by the operator.
Notes on validity range:
swLoadSafetyFileId: Coding according to 'swLoadCurrentFileId'
default value: 0"filename.ext"
Octet #15 contains the ASCII character ":".
swLoadSafetyVersion: Coding according to 'swLoadCurrentVersion'
default value: "cn-hh-vv-ii-ss-pp_yy-mm-dd"
The value 'not valid' for this attribute is indicated via '0' as byte 3.
Validity Range
39..39 characters string
Default Value
None.
Contained in the following commands:
GET BTSEP SWL, SET BTSEP

SWLDST
swLoadsStored
This attribute contains the file IDs (= file ID for a SW load) and version numbers of up to
three SW loads, that are stored in the BTSE Flash Eprom. The attribute is divided into
3 main parts, each part split up in the fileID and file version of one SW load.
In principle there are two different 'kinds' of values for one load version: one indicating
the file ID and load version number of the SW load of the BTSE, that has been successfully downloaded and that has been recognized by the BTSE as a complete load; the
second one, the 'not valid' value, indicating that no load has been downloaded into that
partition of the BTSE Flash Eprom, or that the download is not complete, or that the
stored SW load is corrupted as the check sum is not correct any more.
Octets #15, #55 and #93 contain the ASCII character ":".
The value 'not valid' is indicated as 0 (hexadecimal) for the octets #3 or #42 or #81.

A50016-G5100-B333-04-7619

Id:0900d8058024ebff

717

BS-4x / 82 II / 240 / 241 / 240XL commands

Validity Range
3 to 3 items of
39..39 characters string
Default Value
None.
Contained in the following commands:
GET BTSEP SWL

SYNCSRC
syncSource
This attribute specifies the preferred synchronization source, i.e. whether the BTSE
should be synchronized via Abis or to a 3rd party GPS receiver.
If the attribute value is extGPS further attributes become relevant:
- enableInterSiteSync
- burstNumberOffset
- frameNumberOffset
- maxPhaseError
- maxResyncTime
By setting the syncSource attribute to ext_1pps_only the BTSE 1 is synchronized to an
external device which delivers 1pps pulses. There is no switching to a secondary synchronization source if the 1pps signal fails.
The attribute "1pps only" is supported only for COBA4P12v2 and CESCOBA.
Validity Range
abis
extGPS
ext_1pps_only
Default Value
abis
Contained in the following commands:
GET SYNCBTSE, SET SYNCBTSE

SYNCSTAT
syncState
This attribute indicates the details of the synchronisation process of the BTSE.
Validity Range
init

718

Id:0900d8058024ebff

A50016-G5100-B333-04-7619

BS-4x / 82 II / 240 / 241 / 240XL commands

ready
abis
abisHoldMode
syncUnit
syncUnitHoldMode
Default Value
None.
Contained in the following commands:
GET SYNCBTSE

SYSID
cellAllocationNumber
This attribute indicates the frequency band used by the traffic channels.
Validity Range
BB900
DCS1800
F2ONLY900
EXT900
PCS1900
GSMR
GSMDCS
GSM850
GSM850PCS
GSM850DCS
Default Value
None.
Contained in the following commands:
GET BTS

A50016-G5100-B333-04-7619

Id:0900d8058024ebff

719

BS-4x / 82 II / 240 / 241 / 240XL commands

t
T200
t200
This attribute contains values for the LapDm timer T200 to be used on different control
channels.
Validity Range
sdcchSAPIO

0 - 255

facchTCHF

0 - 255

facchTCHH

0 - 255

saccchTCHSAPIO

0 - 255

sacchSDCCH

0 - 255

sdcchSAPI3

0 - 255

sacchTCHSAPI3

0 - 255

Default Value
SDCCH

29 ms

FACCH/Full rate

31 ms

FACCH/Half rate

38 ms

SDCCH SAPI3

90 ms

SACCH with TCH SAPI0 70 ms


SACCH with SDCCH
SACCH with TCH

29 ms
168 ms

Contained in the following commands:


GET BTS TIMER

T3105
btsTimer3105(*10ms)
This attribute contains the value of the timer T3105, which is used for the repetition of
the PHYSICAL INFORMATION message.
The attribute step size is 10 msec.
Validity Range
1 - 254
Default Value
1 (corresponding to 10 ms)
Contained in the following commands:
GET BTS

720

Id:0900d80580592ba0

A50016-G5100-B333-04-7619

BS-4x / 82 II / 240 / 241 / 240XL commands

T3115
t3115(*10ms)
T3115 is a timer to define the repetition rate of sending the VGCS UPLINK GRANT
message. In case of a ASCI-call the network grants the uplink to one mobile station by
sending a VGCS UPLINK GRANT message to the mobile station. After having sent this
message the BTS starts T3115 to repeat this message as long as a counter not reached
the value of ny2 or a correctly decoded frame was received.
(value indicated in milliseconds; step size 10 ms)
Validity Range
1 - 254
Default Value
4 (corresponding to 40 ms)
Contained in the following commands:
GET BTS TIMER

T3151
uplBusyRepRate
This attribute determines the repetition rate for the upl_busy message per cell. Default
suggested value: 3 sec.
Validity Range
1-9
Default Value
None.
Contained in the following commands:
GET BTS

TAADJ
taAdjust(microseconds)
This attribute takes the propagation delay created on the BTS internal signal path into
account. It comprises both transmit and receive direction i.e. it is the sum of the transmit
delay and the receive delay. The attribute taAdjust refers to the whole cell.
(value indicated in nanoseconds; step size 100 ns).
Validity Range
0.0 - 10.0
Default Value
0 (0 nanoseconds)

A50016-G5100-B333-04-7619

Id:0900d80580592ba0

721

BS-4x / 82 II / 240 / 241 / 240XL commands

Contained in the following commands:


GET BTS TIMER

TCC
txCoherentComb
This attribute allows the user to enable/disable the transmission coherent combining for
FlexCU V2 feature.
Validity Range
TRUE

The user can set the TRUE value only when THE
FCUMODE attribute equals doubleCUMode

FALSE
Default Value
FALSE
Contained in the following commands:
CREATE FCUMAIN, GET FCUMAIN, SET FCUMAIN

TCCCHLDI
thresholdCcchLoadIndication
This attribute is used if the Paging Overload Handling is active in the BTS (see "periodCCHLoadInd"), to stop the Paging Overload Regulation, when the Paging Load goes
below the threshold.
Suggested value is: 50 (hex).
Note that when Paging Overload is active, all Pagings with IMSI are discharged until the
Paging Load goes below the threshold.
Note: in case of ASCI enabled in the cell, that is P1 Rest Octets for NCH info are set in
Paging Request Type 1, only one IMSI could fit in a Paging Request Type 1 and even
though Paging Load is only 50%, there is not enough space for the second IMSI in
Paging Request Type 1. In this case it could make sense to set the threshold to lower
values but take care that meanwhile all Pagings with IMSI are discharged.
The attribute value is indicated in %.
Validity Range
0 - 100
Default Value
100%
Contained in the following commands:
GET BTS

722

Id:0900d80580592ba0

A50016-G5100-B333-04-7619

BS-4x / 82 II / 240 / 241 / 240XL commands

TDMAP
tdmMapping
This attribute determines the mapping of the payload data to internal TDM ports of virtual
BPORT corresponding to the given instance of CESPW. For each payload time slot
(pTs), which is contained in the UDP stream the target time slot number on the virtual
bport has to be set. Only subsequent payload time slots beginning with pTs1 can be
selected. The value 0 means no mapping.
Validity Range
pTs1

0 - 31

pTs2

0 - 31

pTs3

0 - 31

pTs4

0 - 31

pTs5

0 - 31

pTs6

0 - 31

pTs7

0 - 31

pTs8

0 - 31

pTs9

0 - 31

pTs10

0 - 31

pTs11

0 - 31

pTs12

0 - 31

pTs13

0 - 31

pTs14

0 - 31

pTs15

0 - 31

pTs16

0 - 31

pTs17

0 - 31

pTs18

0 - 31

pTs19

0 - 31

pTs20

0 - 31

pTs21

0 - 31

pTs22

0 - 31

pTs23

0 - 31

pTs24

0 - 31

pTs25

0 - 31

pTs26

0 - 31

pTs27

0 - 31

pTs28

0 - 31

pTs29

0 - 31

A50016-G5100-B333-04-7619

Id:0900d80580592ba0

723

BS-4x / 82 II / 240 / 241 / 240XL commands

pTs30

0 - 31

pTs31

0 - 31

Default Value
None.
Contained in the following commands:
CREATE CESPW, GET CESPW, SET CESPW

TEI
tei
This attribute contains the Terminal Endpoint Identifier used in the layer2 addressing on
the Abis-Interface for the logical O&M or Radio Signalling Link.
The values 0..63 of the validity range refers tro the 'Initial TEI'
Validity Range
In commands GET BTSM NOSWL, GET TRX:
0 - 128
In commands SET BTSM:
0 - 63
Default Value
None.
Contained in the following commands:
GET BTSM NOSWL, GET TRX, SET BTSM

TESTMODE
enableTestMode
This attribute determines whether transceiver test mode can be activated. This is only
possible for non BCCH transceivers if their administrative state is "locked". If the test
mode is activated, the transceiver sends dummy bursts on all time slots with the frequency dlTestFrequency and the output power reduced by testPowerReduction. All
other transceiver attributes are meaningless in test mode in the DL direction. In UL direction the transceiver attributes for normal operation apply.
If the test mode is deactivated, the attributes for normal operation apply in DL direction
again and the attributes dlTestFrequency and testPowerReduction are meaningless
instead.
Validity Range
TRUE
FALSE

724

Id:0900d80580592ba0

A50016-G5100-B333-04-7619

BS-4x / 82 II / 240 / 241 / 240XL commands

Default Value
None.
Contained in the following commands:
GET TRX

TESTMON
testMonitor
Up to 6 testMonitorInfo fields can present (depend on the board).
Working phases:
ACDCP

ACT

PreliminaryTestsAcdcp

BootEepromTestCu

EndTestAcdcp

SerialEepromTestCu

PreliminaryTestsAct

LocalTestLoopCu

CheckAlarmStatusAct

EndTestCu
PreliminaryTestsDilna
CheckAlarmStatusDilna

CheckAlarmStatusBattery

EndTestDilna
DIDCTMA

PreliminaryTestsDidctma

PreliminaryTestsCoba

CheckAlarmStatusDidctma

BootEepromTestCoba

EndTestDidctma

SerialEepromTestCoba

COSA

DILNA

PreliminaryTestsBattery

EndTestBattery
COBA

PreliminaryTestsCu

CheckAlarmStatusAcdcp

EndTestAct
BATTERY

CU

DUDCTMA PreliminaryTestsDudctma

EndTestCoba

CheckAlarmStatusDudctma

PreliminaryTestsCosa

EndTestDudctma

SerialEepromTestCosa

DULNA

EndTestCosa

PreliminaryTestsDulna
CheckAlarmStatusDulna
EndTestDulna

Working phases:
DUVSWR

FANP

PreliminaryTestsDuvswr

LMU

CheckAlarmStatusDuvswr

CheckAlarmStatusLmu

EndTestDuvswr

EndTestLmu

PreliminaryTestsFanp

FTNFP

PreliminaryTestsFtnfp

CheckAlarmStatusFanp

CheckAlarmStatusFtnfp

EndTestFanp

EndTestFtnfp

FCUMAIN PreliminaryTestsFcumain

FVSWRP

BootEepromTestFcumain

A50016-G5100-B333-04-7619

PreliminaryTestsLmu

Id:0900d80580592ba0

PreliminaryTestsFvswrp
CheckAlarmStatusFvswrp

725

BS-4x / 82 II / 240 / 241 / 240XL commands

SerialEepromTestFcumain
EndTestFcumain
FCUTR

EndTestFvswrp
SYNCBTSE

PreliminaryTestsSyncbtse

PreliminaryTestsFcutr

ResyncTestSyncbtse

LocalTestLoopFcutr

EndTestSyncbtse

EndTestFcutr

TMA

PreliminaryTestsTma
CheckAlarmStatusTma
EndTestTma

Validity Range
1 to 6 items of
phaseId

PreliminaryTestsAct
PreliminaryTestsCu
PreliminaryTestsCoba
PreliminaryTestsCosa
PreliminaryTestsFanp
PreliminaryTestsDilna
PreliminaryTestsDuvswr
PreliminaryTestsDulna
PreliminaryTestsBattery
PreliminaryTestsBcom
PreliminaryTestsTma
PreliminaryTestsDudctma
PreliminaryTestsDidctma
PreliminaryTestsAcdcp
PreliminaryTestsFvswrp
PreliminaryTestsFtnfp

726

Id:0900d80580592ba0

A50016-G5100-B333-04-7619

BS-4x / 82 II / 240 / 241 / 240XL commands

PreliminaryTestsLmu
PreliminaryTestsSdulna
PreliminaryTestsSdusec
PreliminaryTestsSdusubsec
PreliminaryTestsSdutxsw
EndTestAct
EndTestCu
EndTestCoba
EndTestCosa
EndTestFanp
EndTestDilna
EndTestDuvswr
EndTestDulna
EndTestBattery
EndTestTma
EndTestDudctma
EndTestDidctma
EndTestFvswrp
EndTestFtnfp
EndTestLmu
EndTestSdulna
EndTestSdusec
EndTestSdusubsec
EndTestSdutxsw
SerialEepromTestCu
SerialEepromTestCoba
SerialEepromTestCosa
BootEepromTestCu
BootEepromTestCoba

A50016-G5100-B333-04-7619

Id:0900d80580592ba0

727

BS-4x / 82 II / 240 / 241 / 240XL commands

CheckAlarmStatusAct
CheckAlarmStatusFanp
CheckAlarmStatusDilna
CheckAlarmStatusDuvswr
CheckAlarmStatusDulna
CheckAlarmStatusBattery
CheckAlarmStatusBcom
CheckAlarmStatusTma
CheckAlarmStatusDudctma
CheckAlarmStatusDidctma
CheckAlarmStatusAcdcp
CheckAlarmStatusFvswrp
CheckAlarmStatusFtnfp
CheckAlarmStatusLmu
CheckAlarmStatusSdulna
CheckAlarmStatusSdusec
CheckAlarmStatusSdusubsec
CheckAlarmStatusSdutxsw
LocalTestLoopCu
SerialEepromTestFcumain
ResynctestSyncBtse

728

Id:0900d80580592ba0

A50016-G5100-B333-04-7619

BS-4x / 82 II / 240 / 241 / 240XL commands

PreliminaryTestsSyncBtse
PreliminaryTestsFcutr
PreliminaryTestsFcumain
LocalTestLoopFcutr
EndTestSyncBtse
EndTestBcom
EndTestFcutr
EndTestFcuMain
BootEepromTestFcumain
PreliminaryTestsDuamco
CheckAlarmStatusDuamco
EndTestDuamco
PreliminaryTestsF6
dctma
PreliminaryTestsF6l
na
PreliminaryTestsF6t
nfP
PreliminaryTestsF6v
swrP
CheckAlarmStatusF
6dctma
CheckAlarmStatusF
6lna
CheckAlarmStatusF
6tnfP
CheckAlarmStatusF
6vswrP
EndTestF6dctma
EndTestF6lna
EndTestF6tnfP
EndTestF6vswrP
phaseStatus

Waiting 00
Pass 01

A50016-G5100-B333-04-7619

Id:0900d80580592ba0

729

BS-4x / 82 II / 240 / 241 / 240XL commands

Fail 02
Running 03
Default Value
None.
Contained in the following commands:
GET BTSETEST

TESTNO
testNo
This attribute corrisponde to the instance numeber of the test object.
Validity Range
0 - 255
Default Value
None.
Contained in the following commands:
STOPTEST BTSEP

TESTOUT
testOutcome
This attribute informs the operator about the outcome of the current test phase. It is contained in the "Test Report" and can be queried by the user during the test via a "GET".
INCONCLUSIVE indicates that no "Pass" or " Fail" outcome has been determinated yet.
PASSED and FAIL are possible for all phases of the test. Further information (e.g. about
the number of the failed test phase) is only available in the test report which is sent at
the end of the test.
PASSED generally indicates that the test was executed correctly and no problems were
found.
FAILED generally indicates that the test was executed correctly and a problem was
found.
Validity Range
INCONCLUSIVE
PASSED
FAILED
Default Value
None.

730

Id:0900d80580592ba0

A50016-G5100-B333-04-7619

BS-4x / 82 II / 240 / 241 / 240XL commands

Contained in the following commands:


GET BTSETEST

TESTPWRRED
testPowerReduction
This attribute defines the output power reduction if the transceiver test mode is activated. Its value is adapted to the static power reduction range.
The default value means that the testPowerReduction is not set and as a consequence
the test mode can not be enabled.
Validity Range
<ANY>
Default Value
None.
Contained in the following commands:
GET TRX

TESTST
testState
This attribute defines the current state of the test.
Validity Range
IDLE
INITIALIZING
TESTING
TERMINATING
Default Value
None.
Contained in the following commands:
GET BTSETEST

TIMEDELAY
timeDelay(sec)
This parameter is sent in the 'Activate SW Delayed' command by the BSC. It identifies
the number of seconds that the BTSE waits before activating the specified SW version.
Validity Range
0 - 254

A50016-G5100-B333-04-7619

Id:0900d80580592ba0

731

BS-4x / 82 II / 240 / 241 / 240XL commands

Default Value
None.
Contained in the following commands:
ACTIVATE_DELAYED BTSM

TNCH
tNCH(*multiframes)
This attribute describes the minimum repetition period for the Notification/NCH messages. The NCH blocks are a subset of the CCCH blocks reserved for AGCH.
The attribute doesn't denote the minimum repetition period within one CCCH block.
Within a CCCH block 1 ... 7 NCH blocks can be used.
(the attribute is indicated in units of multiframes)
Validity Range
1 - 254
Default Value
16
Contained in the following commands:
GET BTS TIMER

TNFTARGF
tnfTargetFrequency
This attribute defines the target frequency the TNF is to be tuned. It is
set internally by the BTSE after creation, frequency update or deletion
of any functional-related TRX instance and is read-only for any
external interface of the BTSE.
In case of "FTNFP" the attribute shows the "actual frequency" of the
TNF: this means that the value of the attribute changes during the
"tuning" of the TNF or during the "parking" of the TNF.

732

cellAllocationNumber

Hex

Decimal

GSM900 "BB900"

0001 ... 007C

1 ... 124

GSM EXTENDED
"F2ONLY900"

0000 ... 007C

0 ... 124

03CF ... 03FF

975 ... 1023

GSM EXTENDED
REDUCED
"EXT900"

0000

0000

0000 ... 007C

0 ... 124

03CF ... 03FF

975 ... 1023

Id:0900d80580592ba0

A50016-G5100-B333-04-7619

BS-4x / 82 II / 240 / 241 / 240XL commands

DCS 1800
"DCS1800"

0200 ... 0375

512 ... 885

PCS 1900

0200 ... 032A

512 ... 810

GSM-R

not supported

not supported

ANY (only Parking


position)

FF00

65280

Validity Range
0 - 65535
<NULL>
Default Value
None.
Contained in the following commands:
GET F6TNFP, GET FTNFP

TRXAREA
trxArea
This attribute specifies whether a TRX belongs to a concentric cell and to which area it
belongs.
The attribute also indicates whether the concentric cell intracell handover algorithm is
enable (value 01 or 02) or disabled (value 00). If it is enabled it will be executed before
the conventional inter/intracell handover algorithms.
Validity Range
NONE
INNER
COMPLETE
Default Value
NONE - TRX doesn't belong to a concentric cell
Contained in the following commands:
GET TRX

TRXCPBL
trxCapability
This attribute reflects the real capabilities of a TRX after harware has been assigned to
it. It is set after the TRX allocation by the BTSE. If the TRX object is created in advance
or hardware is not allocated to the TRX the attribute has the value unknown. It is readonly from the Abis/LMT point of view (GET TRX). The BSC has to perform a GET on this
attribute each time the TRX performs a transition to "enabled".

A50016-G5100-B333-04-7619

Id:0900d80580592ba0

733

BS-4x / 82 II / 240 / 241 / 240XL commands

Validity Range
UNKNOWN
GSM
EDGE
Default Value
UNKNOWN
Contained in the following commands:
GET TRX

TRXFREQ
carrierFrequency
This attribute defines the radio frequency allocated and available to a
cell.

cellAllocationNumber

Decimal

GSM900 "BB900"

1 ... 124

GSM EXTENDED
"F2ONLY900"

0 ... 124

GSM-R

955 ... 974

GSM EXTENDED
REDUCED
"EXT900"

0 ... 124

DCS 1800
"DCS1800"

512 ... 885

PCS 1900

512 ... 810

GSM-DCS

0 ... 124

975 ... 1023

975 ... 1023

975 ... 1023


512 ... 885
GSM850

128 ... 251

GSM850-PCS

128 ... 251


512 ... 810

GSM850-DCS

128 ... 251


512 ... 885

Validity Range
0 to 64 items of

734

Id:0900d80580592ba0

A50016-G5100-B333-04-7619

BS-4x / 82 II / 240 / 241 / 240XL commands

0 - 1023
Default Value
None.
Contained in the following commands:
GET TRX

TRXMD
trxMode
This attribute defines the mode of a TRX that required from the operator. Depending on
it's value the BTSE tries to allocate an appropriate hardware to the TRX object.
Validity Range
GSM
EDGE
Default Value
GSM
Contained in the following commands:
GET TRX

TSC
trainingSequenceCode
This attribute contains the Training Sequence Code (TSC) of a radio
channel. If the TSC value is set NULL, TSC is always equal to the
BCC (Base Transceiver Station Colour Code) for both control and
traffic channels.
Notes:
1.

A NULL (FF) value is possible for both control and traffic


channels and signifies that the BCC (BS colour code of attribute "bsIdentityCode / BSIC") shall be used as the TSC value
for the channel.

2.

In case of a control channel only the NULL (FF) value can be


specified, i.e. only a reference to the BCC is allowed.

Validity Range
TSC_00
TSC_01
TSC_02
TSC_03

A50016-G5100-B333-04-7619

Id:0900d80580592ba0

735

BS-4x / 82 II / 240 / 241 / 240XL commands

TSC_04
TSC_05
TSC_06
TSC_07
TSC_is_BCC_of_BSIC
Default Value
None.
Contained in the following commands:
GET CHAN

TSLPOOL
tslPool
This attribute defines the pool of Abis timeslots (TSL) on a granularity
of 16Kbit/s subslots (SSL) which can be used for traffic within a
BTSE.
The attribute contains an entry of 17 bytes for each used BPort:
-

the first byte indicates the number of the BPort (BPortNumber),

the following 16 bytes (BPortBitmap) contain a bitmap - the


subslots which can be used for traffic are indicated by setting
the corresponding bits in the BPortBitmap bytes to 1. In case
of PCM24 the TSL 0 and TSL 25-31 don't exist, therefore the
related bits are set to 0.

Out of this pool the BSC assigns dynamically the Abis timeslots to a
call. The information about the actual timeslot/subslot ("Abis
Resources") is sent by the BSC to the BTSE on the radio signalling
link at the begin of each call ("channel Activation") and during the call
("Modify Abis Channel") if a modification is necessary.
The BportNumber validity range is specified as follows:
00..07 (not only for BS82II)
00..03 (only for BS82II)
Validity Range
1 to 8 items of
BPortNumber

BPORT0
BPORT1
...
BPORT7

BPortBitMap

736

16 to 16 items of

Id:0900d80580592ba0

A50016-G5100-B333-04-7619

BS-4x / 82 II / 240 / 241 / 240XL commands

B#0 - B#11111111
Default Value
None.
Contained in the following commands:
GET BTSM NOSWL

TSYNC
tSync(*10ms)
This attribute defines the timer value, that will be used by the BTS to supervise timeout
of TRAU frame handling. This timer is used only if a BTS-TRAU traffic connection is
already established. If the BTSE detects a loss of frame synchronisation it starts the
timer tSync. It is cleared, if a frame is received again. If it expired, a connection failure
indication is reported to the BSC.
A change of the attribute becomes effective after the reception of a TRAU frame i.e. in
the case after 20 ms and in the worst case after the expiration of the current timer.
(value indicated in milliseconds; step size 10 ms)
Validity Range
10 - 10000
Default Value
1000 (corresponding to 10 sec.)
Contained in the following commands:
GET BTS TIMER

TSYNCD
tSyncD(*10ms)
This attribute defines the timer value, that will be used by the BTS to supervise timeout
of downlink TRAU frame handling in case of 14.5kbit/s data connections. If loss of frame
synchronization detected by the BTS it starts a timer TsyncD and starts sending Data
TRAU Frames in the uplink direction to trigger the TRAU to start sending Data TRAU
Frames in the downlink direction to be used for downlink Synchronization Recovery.
TsyncD is reset every time frame synchronization is again obtained. If TsyncD expires
before frame synchronization is again obtained, a connection failure indication is
reported to the BSC.
(value indicated in milliseconds; step size 10 ms)
Validity Range
10 - 10000

A50016-G5100-B333-04-7619

Id:0900d80580592ba0

737

BS-4x / 82 II / 240 / 241 / 240XL commands

Default Value
1000 (corresponding to 100 sec.)
Contained in the following commands:
GET BTS TIMER

TSYNCR
tSyncR(*10ms)
This attribute defines the timer value, that will be used by the BTS to supervise the uplink
Synchronization Recovery in case of 14.5kbit/s data connections. When the BTS
receives an Extended Data TRAU Frame indicating an Uplink Frame Error and which
has no errors on the synchronization pattern and the control bits, it starts the timer
TsyncR. TsyncR is reset every time three consecutive TRAU frames are received
without Uplink Frame Error indication, without errors on the frame synchronization
pattern and on the control bits. If TsyncR expires before frame synchronization is again
obtained, the BTS starts sending Data TRAU Frames in the uplink direction to be used
for uplink Synchronization Recovery.
(value indicated in milliseconds; step size 10 ms)
Validity Range
10 - 10000
Default Value
400 (corresponding to 4 sec.)
Contained in the following commands:
GET BTS TIMER

TSYNCU
tSyncU(*10ms)
This attribute defines the timer value, that will be used by the BTS to supervise timeout
of uplink TRAU frame handling in case of 14.5kbit/s data connections. When the BTS
receives an Extended Data TRAU Frame indicating an Uplink Frame Error and which
has no errors on the synchronization pattern and the control bits, it starts a timer
TsyncU. TsyncU is reset every time three consecutive TRAU frames are received
without Uplink Frame Error indication, without errors on the frame synchronization
pattern and on the control bits. If TsyncU expires before frame synchronization is again
obtained, a connection failure indication is reported to the BSC.
(value indicated in milliseconds; step size 10 ms)
Validity Range
10 - 10000

738

Id:0900d80580592ba0

A50016-G5100-B333-04-7619

BS-4x / 82 II / 240 / 241 / 240XL commands

Default Value
1000 (corresponding to 10 sec.)
Contained in the following commands:
GET BTS TIMER

TTRAU
tTrau(*10ms)
This attribute defines the timer value, that will be used by the BTS to supervise timeout
of TRAU datalink (traffic) at connection establishment or handover. It is set with sending
the first TRAU dataframe uplink and cleared, when the first frame downlink arrives. If it
is expires, a connection failure indication is reported to the BSC.
(value indicated in milliseconds; step size 10 ms)
Validity Range
10 - 10000
Default Value
1000 (corresponding to 10 sec.)
Contained in the following commands:
GET BTS TIMER

TUPLREP
timerUplinkReply
The attribute defines the timer for the repetition of the UplinkFree message with "reply
on uplink access request".
Validity Range
5 - 60
Default Value
20 seconds
Contained in the following commands:
GET BTS TIMER

TXBMAXF
txBandMaxFreq(kHz*100)
Attribute data provided by the TMA.
Validity Range
0 - 65535

A50016-G5100-B333-04-7619

Id:0900d80580592ba0

739

BS-4x / 82 II / 240 / 241 / 240XL commands

<NULL>
Default Value
None.
Contained in the following commands:
GET TMA

TXBMINF
txBandMinFreq(kHz*100)
Attribute data provided by the TMA.
Validity Range
0 - 65535
<NULL>
Default Value
None.
Contained in the following commands:
GET TMA

TXDIVTSEXCPT
txDivTimeShiftExcept
The TX Diversity Time Shift operation might be disabled for certain type of TX burst,
which are timing-sensitive (e.g. SCH channel for location services). In this case the
parallel transmission of the slave CU is disabled when the certain burst type is going to
be transmitted. The attribute txDivTimeShiftExcept allows to configure time slots or
logical channels, which shall be excluded from applying the Tx Diversity Time Shift. The
call processing software supervises bursts to be transmitted and disables the slave
transmission if the burst should not be transmitted. The attribute is only valid if the
feature Tx Diversity Time Shift is enabled (attribute enableTxDivTimeShift). A change of
the attribute value causes a traffic interruption on all TRX of the BTS and a restart of the
feature Tx Diversity Time Shift.
Validity Range
NONE
SCH
BCCHTRXTS0
BCCHTRX
Default Value
NONE (diversity applied for all channel)

740

Id:0900d80580592ba0

A50016-G5100-B333-04-7619

BS-4x / 82 II / 240 / 241 / 240XL commands

Contained in the following commands:


GET BTS TIMER

TXDIVTSPAR
txDivTimeShiftParam
The attribute txDivTimeShiftParam is used to set the time shift between the transmit
signals of the master and the slave CU. The time shift is specified on a symbol base in
the range between -5 .... +5 symbols in steps of 0,25 symbols. A symbol represents one
information unit (e.g. 1 bit) is transmitted within 3,693 s. The attribute is only valid if the
feature Tx Diversity Time Shift is enabled (attribute enableTxDivTimeShift). A change of
the attribute value causes a traffic interruption on all TRX of the BTS and a restart of the
feature Tx Diversity Time Shift.
Validity Range
-5.00 - 5.00
Default Value
-1 symbol, but has to be evaluated during field tests
Contained in the following commands:
GET BTS TIMER

TXLEVADJ
txLevAdjust(dB)
The attribute specifies the value needed to adjust the TXLEV value of
the transmit path of the CU/FCUTR. For a FCUTR with an even object
instance the related transmit path is TX0, for a FCUTR with an odd
object instance the related transmit path is TX1.
The attribute value which will be used to compensate attenuation
effects caused by combiner equipment, RF cabling and amplification
effects of optionally used booster equipment. The operator has to set
a reasonable value according the following formula:
txLevAdjust =

Attention Factor of used Combiner + Attention


Factor of RF Cable - Amplification Factor of used
Booster

Validity Range
-63.0 - 63.0
Default Value
0.0
Contained in the following commands:
CREATE CU, CREATE FCUTR, GET CU, GET FCUTR, SET CU, SET FCUTR

A50016-G5100-B333-04-7619

Id:0900d80580592ba0

741

BS-4x / 82 II / 240 / 241 / 240XL commands

TXSIGLEVADJ
txSigLevAdjust
The attribute specifies the signal level adjust values which shall be applied to the
transmit paths oftransceivers using the same frequency band as the BCCH transceiver.
Validity Range
<ANY>
Default Value
None.
Contained in the following commands:
GET BTS TIMER

TXSIGLEVADJC
txSigLevAdjustCompl
The attribute specifies the signal level adjust values which shall be applied to the
transmit paths oftransceivers using the complementary frequency band. The value is
only meaningful in case of a multiband cell.
Validity Range
<ANY>
Default Value
None.
Contained in the following commands:
GET BTS TIMER

TYPOFETH
typeOfEthernet
The attribute defines the type of Ethernet framing which is used for transmitted packets.
Validity Range
ethernet_II
iEEE802_SNAP
Default Value
ethernet_II
Contained in the following commands:
GET COBAETHINTF, SET COBAETHINTF

742

Id:0900d80580592ba0

A50016-G5100-B333-04-7619

BS-4x / 82 II / 240 / 241 / 240XL commands

TYPRACK
typeOfBtse
This attribute identifies the type of BTSE.
This attribute defines the type of the rack.
For the BTSE family given by 'hh=04' it is possible to set the value of typeOfBTSE for
rack #0 only once - if the operator wants to change the stored value he has to format the
FLASH EPROM first or delete the Flash-DB.
For an rack instance number <> 0 an update of the attribute is blocked by the BTSE SW.
This means if an operator wants to change the attribute value in a rack <> 0 he has to
delete the rack first and then recreate it with the new value of typeOfBTSE.
Below are reported more detailed information about the validity range:
BS20 (value only possible for rack #0)
BS21E (value only possible for rack #0)
BS22 (value only possible for rack #0)
BS60 (value only possible for rack #0)
BS61E (value only possible for rack #0)
not_valid (value possible only in LMT phase 2 as result of a
GET command for rack #0)
Validity Range
In commands CREATE RACK, SET RACK:
BS240
BS241
BS240SR
BS241SR
BS40
BS40II
BS41
BS240XL
BS240XLSR
BS82II
In commands GET RACK:
BS240
BS241
BS240SR
BS241SR
BS40
BS41
BS240XL

A50016-G5100-B333-04-7619

Id:0900d80580592ba0

743

BS-4x / 82 II / 240 / 241 / 240XL commands

BS240XLSR
BS240XS
BS240SWB
BS241SWB
BS240XLSWB
BS82II
BS40II
not_valid
Default Value
None.
Contained in the following commands:
CREATE RACK, GET RACK, SET RACK

744

Id:0900d80580592ba0

A50016-G5100-B333-04-7619

BS-4x / 82 II / 240 / 241 / 240XL commands

v
VENDNA
vendorName
This attribute type identifies the vendor of the associated Object. This attribute is defined
as an "ASCII String" and is not terminated by a NULL character.
Validity Range
1..37 characters string
Default Value
None.
Contained in the following commands:
GET BTSEP NOSWL, SET BTSEP

VGSCULFT
voiceGroupUplinkFree(*10ms)
If the uplink of the group call is free, and also no talker is in the cell on
a dedicated channel, the network provides an UPLINK FREE
message on the main signalling channel periodically. The timer
vgscULFreeTimer plus an offset of 440ms defines the repetition rate
of sending this message; the BTS limits the maximum repetition rate
on 1440ms.
The BTSE stops the timer when the uplink is free again, and also no
talker is in the cell on a dedicated channel.
Setting this attribute to the lowest possible value means that a talker
request by a mobile station can be started with most minimal delay.
On the other side, a high repetition rate of UPLINK FREE messages
leads to a certain speech frame erasure rate, which may cause an
audible degradation of the speech quality on the group downlink
channel; although there is no talker in the group call at this state, there
may be dispatchers speaking on the group downlink channel.

vgcsULFreeTimer
value (decimal)

vgcsULFreeTimer

UPLINK FREE

* 10 ms

repetition rate

10 ms

450 ms

20 ms

460 ms

30 ms

470 ms

100

100 ms

1440 ms

A50016-G5100-B333-04-7619

Id:0900d80580592ba2

745

BS-4x / 82 II / 240 / 241 / 240XL commands

Default Value: 10 ms
Validity Range
1 - 100
Default Value
10 ms
Contained in the following commands:
GET BTS TIMER

VLANID
vlanId
This attribute defines optional virtual LAN (VLAN) identifier. The vlanId is used by all
pseudo wires (CESPW) of the CESTUNNEL instance.
If vlanId is set to none the VLAN tag in the Ethernet Header will be omitted. The object
must be locked before modifying the vlanId via the SET command.
Validity Range
In commands CREATE CESTUNNEL, CREATE CESTUNNEL, SET CESTUNNEL:
0 - 4094
<NULL>
In commands GET CESTUNNEL:
<ANY>
Meaning:

1..4094 :Tagged frame mode: IEEE 802.1q


TX: All frames contain vlan tags with value of attribute vlanId and priority tags;
default priority is 7 if no other value is configured with BTSE attribute serviceClassPrioList.
RX: Only tagged frames with vlanId=attribute value are accepted; untagged frames
(no vlan tag and no priority tag) are discarded
0: Tagged frame mode: IEEE 802.1p
TX:all frames contain vlan tags with vlanId=0 and priority tags with default value=7
if no other value is configured with BTSE attribute serviceClassPrioList.
RX: frames with priority tag + vlan tag =0 must be accepted, untagged frames with
no vlan tag and no priority tag should be also accepted; all others are discarded
None: Untagged frame mode:
TX:all frames are untagged (no vlan tag and no priority tag)
RX:untagged frames with no vlan tag and no priority tag must be accepted, frames
with priority tag + vlan tag=0 should be also accepted; all others are discarded

Default Value
In moc(s) CESTUNNEL:
None.

746

Id:0900d80580592ba2

A50016-G5100-B333-04-7619

BS-4x / 82 II / 240 / 241 / 240XL commands

In moc(s) CESTUNNEL:
NULL
Contained in the following commands:
CREATE CESTUNNEL, GET CESTUNNEL, SET CESTUNNEL

VSWRTDB
vswrThresholdDb
The value sets the TX return loss threshold value of an MFDUAMCO antenna branch.
The value will be aligned with the combiner if a MFDUAMCO is equipped.
The value will be aligned with the combiner if a FICOM6 is equipped.
The object is set to degraded if the low threshold is crossed. Crossing the high threshold
leads to disabled state.
The attribute is meaningless if an old DUAMCO or FDUAMCO is equipped. Nevertheless the value will be stored in the database and used if an MFDUAMCO will be
equipped later on.
Validity Range
LOW_2_0_HIGH_3_0
LOW_2_5_HIGH_3_5
LOW_3_0_HIGH_4_0
Default Value
LOW_2_0_HIGH_3_0
Contained in the following commands:
CREATE DUVSWR, CREATE F6VSWRP, GET DUVSWR, GET F6VSWRP, SET
DUVSWR, SET F6VSWRP

A50016-G5100-B333-04-7619

Id:0900d80580592ba2

747

BS-4x / 82 II / 240 / 241 / 240XL commands

w
WDDUVSWR
wiringDuamcoVswr
This attribute represents the wiring between a DUAMCO_VSWR and several CUs (TX
output)/FCUMAINs (TX0 output or TX1 output) which the operator has to perform at
installation time.
In case of FCUMAIN with fcuMode=singleCUMode or in case of CU, the
DUAMCO_VSWR and the CUs/FCUMAINs are in the same rack and belong to the
same cell.
In case of FCUMAIN with fcuMode=douleCUMode, the objects can belong to two different cells.
Due to the physical properties of the DUAMCO_VSWR, up to 4 CUs/FCUMAINs can be
connected."
From SW point of view the FDUAMCO is considered just as an HW variant of the
DUAMCO, so an extra term like 'FDUAMCO_DUVSWR' is not introduced.
The BTSE SW doesn't check if the entered value is compatible with typeOfBTSE; e.g.
an input of CU7 isn't rejected in a BS40 although BS40 allows only the creation of CU
0-3.
Notes:
- All CUs/FCUMAINs which are listed in a GET DUVSWR for WDDUVSWR have to be
locked before the cabling of one of these CUs/FCUMAINs can be removed from WDDUVSWR.
- The UIDL construct used is enumList.
Below are reported some detailed information about validity range values:
CU0 ... CU11 (CU4 ... CU7 only for BS240 and BS241)
(CU4 ... CU11 only for BS240XL)
FCUMAIN0TX0
FCUMAIN0TX1
:
FCUMAIN11TX0
FCUMAIN11TX1
(FCUMAIN4TX0 ... FCUMAIN7TX1 only for BS240
and BS241)
:
(FCUMAIN4TX0 ... FCUMAIN11TX1 only for
BS240XL)
Validity Range
1 to 4 items of

748

Id:0900d8058024e40a

A50016-G5100-B333-04-7619

BS-4x / 82 II / 240 / 241 / 240XL commands

CU0
CU1
CU2
CU3
CU4
CU5
CU6
CU7
CU8
CU9
CU10
CU11
FCUMAIN0TX0
FCUMAIN0TX1
FCUMAIN1TX0
FCUMAIN1TX1
FCUMAIN2TX0
FCUMAIN2TX1
FCUMAIN3TX0
FCUMAIN3TX1
FCUMAIN4TX0
FCUMAIN4TX1
FCUMAIN5TX0
FCUMAIN5TX1
FCUMAIN6TX0
FCUMAIN6TX1
FCUMAIN7TX0
FCUMAIN7TX1
FCUMAIN8TX0
FCUMAIN8TX1
FCUMAIN9TX0
FCUMAIN9TX1
FCUMAIN10TX0
FCUMAIN10TX1
FCUMAIN11TX0
FCUMAIN11TX1

A50016-G5100-B333-04-7619

Id:0900d8058024e40a

749

BS-4x / 82 II / 240 / 241 / 240XL commands

Default Value
None.
Contained in the following commands:
CREATE DUVSWR, GET DUVSWR, SET DUVSWR

WDFTNFP
wiringDataFtnfp
This attribute defines the pool of Abis timeslots (TSL) on a granularity
of 16Kbit/s subslots (SSL) which can be used for traffic within a
BTSE.
This attribute represents the wiring:
-

between the TX input of a FICOM_TNFP and the TX output of


a CU

between the TX input of a FICOM_TNFP and the TX0 or TX1


output of a FCUMAIN

and furtheron it describes to which FICOM_VSWR the


FICOM_TNFP is related to. The wiring has to be done by the
operator at installation time.
In case of FCUMAIN with fcuMode=singleCUMode or in case of CU,
the FICOM_TNFP, the CU/FCUMAIN and the FICOM_VSWRP are
in the same rack and belong to the same cell.
In case of FCUMAIN with fcuMode=douleCUMode, the objects can
belong to two different cells.
The BTSE SW doesn't check if the entered value is compatible with
typeOfBTSE; e.g. an input of CU7 isn't rejected in a BS40 although
BS40 allows only the creation of CU 0-3.
Note: 'CU_wiring' is used for CU as well as for FCUMAIN, the name
'CU_wiring' has not been changed because it is used in LMTGUI/CLI.
The following values are possible for 'CU_wiring':
CU0 ... CU11 (CU4 ... CU7 only for BS240 and BS241)
(CU4 ... CU11 only for BS240XL)
FCUMAIN0TX0
FCUMAIN0TX1
:
FCUMAIN11TX0
FCUMAIN11TX1
(FCUMAIN4TX0 ... FCUMAIN7TX1 only for BS240
and BS241)
:

750

Id:0900d8058024e40a

A50016-G5100-B333-04-7619

BS-4x / 82 II / 240 / 241 / 240XL commands

(FCUMAIN4TX0 ... FCUMAIN11TX1 only for


BS240XL)
The following values are possible for 'FVSWRP wiring':
FVSWRP0
FVSWRP1
FVSWRP2
FVSWRP3
Validity Range
CUWiring

CU0
CU1
CU2
CU3
CU4
CU5
CU6
CU7
CU8
CU9
CU10
CU11
FCUMAIN0TX0
FCUMAIN0TX1
FCUMAIN1TX0
FCUMAIN1TX1
FCUMAIN2TX0
FCUMAIN2TX1
FCUMAIN3TX0
FCUMAIN3TX1
FCUMAIN4TX0
FCUMAIN4TX1
FCUMAIN5TX0
FCUMAIN5TX1
FCUMAIN6TX0
FCUMAIN6TX1
FCUMAIN7TX0
FCUMAIN7TX1

A50016-G5100-B333-04-7619

Id:0900d8058024e40a

751

BS-4x / 82 II / 240 / 241 / 240XL commands

FCUMAIN8TX0
FCUMAIN8TX1
FCUMAIN9TX0
FCUMAIN9TX1
FCUMAIN10TX0
FCUMAIN10TX1
FCUMAIN11TX0
FCUMAIN11TX1
FVSWRPWiring

FVSWRP0
FVSWRP1
...
FVSWRP3

Default Value
None.
Contained in the following commands:
CREATE F6TNFP, CREATE FTNFP, GET F6TNFP, GET FTNFP

WDLNA
wiringDataLna
This attribute represents the wiring between a DUAMCO_LNA or a DIAMCO_LNA and
several CUs/FCUMAINs the operator has to perform at installation time and that is not
foreseen to be fixed by the configuration rules.
In case of FCUMAIN with fcuMode=singleCUMode or in case of CU, the
DUAMCO/DIAMCO_LNA and the CUs/FCUMAINs are in the same rack and belong to
the same cell.
In case of FCUMAIN with fcuMode=douleCUMode, the objects can belong to two different cells.
When a second cell number is indicated (see attribute secondCellNumber), also in case
of CU the objects can belong to two different cells.
Due to the physical properties of the DUAMCO_VSWR, up to 8 different Us/FCUMAINs
can be connected. Each CU has a 'normal path' RX input and a 'diversity path' RX input
and the operator must indicate which of them is wired to the DUAMCO/DIAMCO_LNA.
The FCUMAIN supports the 'normal path' RX input, the diversity path RX input and two
further Rx inputs: Rx C / N1 and Rx D / D1.
The BTSE SW doesn't check if the entered value is compatible with typeOfBTSE; e.g.
an input of CU7N / CU7D isn't rejected in a BS40 although BS40 allows only the creation
of CU 0-3.
Validity Range (object DILNA/DULNA) are possible for 'RX_wiring n':
CU0N (CU0 normal path)
CU0D (CU0 diversity path)

752

Id:0900d8058024e40a

A50016-G5100-B333-04-7619

BS-4x / 82 II / 240 / 241 / 240XL commands

:
CU11N (CU11 normal path)
CU11D (CU11 diversity path)
FCUMAIN0N (FCUMAIN0 normal path)
FCUMAIN0D (FCUMAIN0 diversity path)
FCUMAIN0N1 (FCUMAIN0 Rx C / N1 path)
FCUMAIN0D1 (FCUMAIN0 Rx D / D1 path)
:
FCUMAIN11N (FCUMAIN11 normal path)
FCUMAIN011D (FCUMAIN11 diversity path)
FCUMAIN11N1 (FCUMAIN11 Rx C / N1 path)
FCUMAIN11D1 (FCUMAIN011 Rx D / D1 path)
(CU4 ... CU7 only for BS240 and BS241)
(CU4 ... CU11 only for BS240XL)
(FCUMAIN4N ... FCUMAIN7D1 only for BS240 and BS241)
(FCUMAIN4N ... FCUMAIN11D1 only for BS240XL)
Validity Range
1 to 8 items of
CU0N
CU0D
CU1N
CU1D
CU2N
CU2D
CU3N
CU3D
CU4N
CU4D
CU5N
CU5D
CU6N
CU6D
CU7N
CU7D
CU8N
CU8D
CU9N

A50016-G5100-B333-04-7619

Id:0900d8058024e40a

753

BS-4x / 82 II / 240 / 241 / 240XL commands

CU9D
CU10N
CU10D
CU11N
CU11D
FCUMAIN0N
FCUMAIN0D
FCUMAIN0N1
FCUMAIN0D1
FCUMAIN1N
FCUMAIN1D
FCUMAIN1N1
FCUMAIN1D1
FCUMAIN2N
FCUMAIN2D
FCUMAIN2N1
FCUMAIN2D1
FCUMAIN3N
FCUMAIN3D
FCUMAIN3N1
FCUMAIN3D1
FCUMAIN4N
FCUMAIN4D
FCUMAIN4N1
FCUMAIN4D1
FCUMAIN5N
FCUMAIN5D
FCUMAIN5N1
FCUMAIN5D1
FCUMAIN6N
FCUMAIN6D
FCUMAIN6N1
FCUMAIN6D1
FCUMAIN7N
FCUMAIN7D
FCUMAIN7N1

754

Id:0900d8058024e40a

A50016-G5100-B333-04-7619

BS-4x / 82 II / 240 / 241 / 240XL commands

FCUMAIN7D1
FCUMAIN8N
FCUMAIN8D
FCUMAIN8N1
FCUMAIN8D1
FCUMAIN9N
FCUMAIN9D
FCUMAIN9N1
FCUMAIN9D1
FCUMAIN10N
FCUMAIN10D
FCUMAIN10N1
FCUMAIN10D1
FCUMAIN11N
FCUMAIN11D
FCUMAIN11N1
FCUMAIN11D1
Default Value
None.
Contained in the following commands:
CREATE DILNA, CREATE DULNA, CREATE F6LNA, GET DILNA, GET DULNA,
GET F6LNA, SET DILNA, SET DULNA, SET F6LNA

A50016-G5100-B333-04-7619

Id:0900d8058024e40a

755

Nack causes

BS-4x / 82 II / 240 / 241 / 240XL commands

4 Nack causes
String table for ABIS nack causes used by the LMT Evolution

756

H'1,

Incorrect message structure

H'2,

Invalid message type value

H'3,

<reserved>

H'4,

<reserved>

H'5,

Invalid object class value

H'6,

Object class not supported

H'7,

BTS no. unknown

H'8,

Transceiver no. unknown

H'9,

Object instance unknown

H'A,

<reserved>

H'B,

<reserved>

H'C,

Invalid attribute identifier value

H'D,

Attribute identifier not supported

H'E,

Parameter value outside permitted range

H'F,

Inconsistency in attribute list

H'10,

Specified implementation not supported

H'11,

Message cannot be performed

H'12,

Busy

H'13,

<reserved>

H'14,

<reserved>

H'15,

<reserved>

H'16,

<reserved>

H'17,

<reserved>

H'18,

<reserved>

H'19,

Resource not implemented

H'1A,

Resource not available

H'1B,

Frequency not available

H'1C,

Test not supported

H'1D,

Capacity restrictions

H'1E,

Physical configuration cannot be performed

H'1F,

Test not initiated

H'20,

Physical configuration cannot be restored

H'21,

No such test

H'22,

Test cannot be stopped

Id:0900d805805bfe1b

A50016-G5100-B333-04-7619

BS-4x / 82 II / 240 / 241 / 240XL commands

Nack causes

H'23,

Message inconsistent with physical config.

H'24,

File already received

H'25,

Complete file not received

H'26,

File not available at destination

H'27,

File cannot be activated

H'28,

Request not granted

H'29,

Wait

H'2A,

<reserved>

H'7F,

<reserved>

H'80,

BTSE not able to begin DB Transmission

H'81,

DB Transmission failed

H'82,

Conflicting channel assignment

H'83,

Specified connection does not exist

H'84,

Specified Test is not running

H'85,

swLoad-header not stored

H'86,

swLoad-header mismatch with swImage or VAM file id

H'87,

Files listed in swLoad header not stored

H'88,

Request already in progress

H'89,

Load has not been activated before

H'8A,

Starting Time already in use

H'8B,

Configuration of specified object not allowed during alignment

H'8C,

Update of specified object not allowed in LMT Evolution phase 3

H8D,

Configuration of specified object not allowed during FW download

H'90,

invalid file name

H'91,

invalid file type

H'92,

file not found

H'93,

file in use

H'94,

file present

H'95,

file corrupted

H'96,

file test failed

H'97,

MO or MOT not locked

H'98,

VAM check failed

H'99,

VAM file not stored in Flash Eprom

H'9A,

Scanner is suspended

H'9B,

TEI already in use

H'9C,

Update not allowed from Abis interface

A50016-G5100-B333-04-7619

Id:0900d805805bfe1b

757

Nack causes

BS-4x / 82 II / 240 / 241 / 240XL commands

H'9D,

Update not allowed from T interface

H'9E,

Update not allowed

H'9F,

MO already created

H'A0,

requested information exceeds maximal message length

H'A1,

sw load not compatible with typeOfBTSE

H'A2,

Creation out of sequence

H'A3,

Invalid attribute value

H'A4,

Conflicting timeslot assignment

H'A5,

Deletion not possible in Phase3

H'A6,

Deletion out of sequence

H'A7,

Related BPort instance not created

H'A8,

Configuration of remapped timeslots not possible in Phase3

H'A9,

feature not released

H'AA,

typeOfBTSE has to be set first

H'AB,

typeOfBTSE not compatible with typeOfBTSE in other rack(s)

H'AC,

max number of object instances is already created

H'AD,

no redundant core board available

HAE,

TRX/LPDM related LADPLE doesnt exist or isnt consistent

HAF,

Requested data not available

HB0,

Conflicting feature activation

HB1,

Re-synchronization not possible

HB2,

Inconsistency in wiring configuration

HB3,

No FPGA on board

HB4-F3,

Not used

H'F4,

Change password failed: syntax error

H'F5,

Change password failed: new pwd is the same as old pwd

HF6-F7,

Not used

H'F8,

Mandatory security attribute missing

H'F9,

Security transmission failed

H'FA,

Security transmission missing

H'FB-FE,

Not used

H'FF,

NULL

String table for LMT Evolution nack causes used by BTSE

758

H'01,

Incorrect message structure

H'02,

Invalid message type value

H'03,

<reserved>

Id:0900d805805bfe1b

A50016-G5100-B333-04-7619

BS-4x / 82 II / 240 / 241 / 240XL commands

Nack causes

H'04,

<reserved>

H'05,

Invalid object class value

H'06,

Object class not supported

H'07,

BTS no. unknown

H08,

Transceiver no. unknown

H09,

Object instance unknown

H0A,

<reserved>

H0B,

<reserved>

H'0C,

Invalid attribute identifier value

H0D,

Attribute identifier not supported

H0E,

Parameter value outside permitted range

H0F,

Inconsistency in attribute list

H10,

Specified implementation not supported

H'11,

Message cannot be performed

H'12,

System busy

H13,

<reserved>

H14,

<reserved>

H15,

<reserved>

H16,

<reserved>

H17,

<reserved>

H18,

<reserved>

A50016-G5100-B333-04-7619

Id:0900d805805bfe1b

759

Appendix: values for ERFACCHALPDMF, ERFACCHCMDF, ERSACCHDL, ERSACCHUL and ETOP

BS-4x / 82 II / 240 / 241 / 240XL commands

5 Appendix: values for ERFACCHALPDMF,


ERFACCHCMDF, ERSACCHDL, ERSACCHUL and ETOP
Assigned Values
Binary

Dec

Hex

TCH_WFS TCH_HS TCH_FS TCH_EFS TCH_AHS TCH_AFS


0

00

0x00

01

0x01

02

0x02

03

0x03

04

0x04

05

0x05

06

0x06

07

0x07

08

0x08

09

0x09

10

0x0A

11

0x0B

12

0x0C

13

0x0D

14

0x0E

15

0x0F

16

0x10

17

0x11

18

0x12

19

0x13

20

0x14

21

0x15

22

0x16

23

0x17

24

0x18

25

0x19

26

0x1A

27

0x1B

28

0x1C

760

Id:0900d80580248212

A50016-G5100-B333-04-7619

BS-4x / 82 II / 240 / 241 / 240XL commands

Appendix: values for ERFACCHALPDMF, ERFACCHCMDF, ERSACCHDL, ERSACCHUL and ETOP

29

0x1D

30

0x1E

31

0x1F

32

0x20

33

0x21

34

0x22

35

0x23

36

0x24

37

0x25

38

0x26

39

0x27

40

0x28

41

0x29

42

0x2A

43

0x2B

44

0x2C

45

0x2D

46

0x2E

47

0x2F

48

0x30

49

0x31

50

0x32

51

0x33

52

0x34

53

0x35

54

0x36

55

0x37

56

0x38

57

0x39

58

0x3A

59

0x3B

60

0x3C

61

0x3D

62

0x3E

63

0x3F

g ERFACCHALPDMF:

A50016-G5100-B333-04-7619

Id:0900d80580248212

761

Appendix: values for ERFACCHALPDMF, ERFACCHCMDF, ERSACCHDL, ERSACCHUL and ETOP

BS-4x / 82 II / 240 / 241 / 240XL commands

For the binary representation 0 means that R-FACCH for any LAPDm command or
response frames is not applied for specified speech codec type and 1 means that RFACCH for any LAPDm 5 command or response frames is applied for specified
speech codec type.Value 0x00 has specific meaning and should be read as RFACCH for any LAPDm command or response frames is not applied for any speech
codec type. All other values are reserved for the future use.
ERFACCHCMDF: For the binary representation 0 means that R-FACCH on LAPDm
command frames is not applied for specified speech codec type and 1means that RFACCH on LAPDm command frames is applied for apecified speech codec type.
Value 0x00 has specific meaning and should be read as R-FACCH on LAPDm
command frames is not applied for any speech codec type. All other values are
reserved for the future use.
ETOP:
For the binary representation 0 means that TOP is not applied for specified speech
codec type and 1 means that TOP is applied for specified speech codec type.Value
0x00 has specific meaning and should be read as TOP is not applied for any speech
codec type. All other values are reserved for the future use.

762

Id:0900d80580248212

A50016-G5100-B333-04-7619

You might also like