https://www.phoenixcontact.
com/us/products/2814867
Signal conditioner-MCR-FL-C-UI-2UI-DCI-NC-2814867
Please be informed that the data shown in this PDF Document is generated from our Online Catalog. Please find the complete data in the user's
documentation. Our General Terms of Use for Downloads are valid
(http://phoenixcontact.com/download)
MCR signal multiplier, for doubling and electrical isolation of analog signals, unconfigured
Product Features
Calibrated selectable input and output signals
4-way isolation
Key commercial data
Packing unit
1 pc
Weight per Piece (excluding packing)
139.2 GRM
Custom tariff number
85437090
Country of origin
Germany
Technical data
Note
Utilization restriction
EMC: class A product, see manufacturer's declaration in the download
area
Dimensions
Width
17.5 mm
Height
99 mm
Depth
114.5 mm
Ambient conditions
Ambient temperature (operation)
-25 C ... 55 C
Degree of protection
IP20
Input data
01/12/2015Page1/5
https://www.phoenixcontact.com/us/products/2814867
Signal conditioner-MCR-FL-C-UI-2UI-DCI-NC-2814867
Technical data
Input data
Description of the input
Current input
Configurable/programmable
Yes, unconfigured
Current input signal
0 mA ... 24 mA (freely selectable in 0.1 mA steps)
Max. input current
50 mA
Input resistance current input
50
Description of the input
Voltage input
Configurable/programmable
Yes, unconfigured
Voltage input signal
0 V ... 12 V (freely selectable in 0.1 V steps)
Max. input voltage
30 V
Input resistance of voltage input
200 k
Output data
Output name
Current output
Configurable/programmable
Yes, unconfigured
Current output signal
see order key / configuration table
Max. output current
35 mA
Load/output load current output
600
Output name
Voltage output
Configurable/programmable
Yes, unconfigured
Voltage output signal
see order key / configuration table
Max. output voltage
15 V
Load/output load voltage output
10 k
Power supply
Supply voltage range
20 V DC ... 30 V DC
Max. current consumption
< 25 mA
Connection data
Connection method
Pluggable screw connection
Conductor cross section solid min.
0.2 mm
Conductor cross section solid max.
2.5 mm
Conductor cross section AWG/kcmil min.
24
Conductor cross section AWG/kcmil max
14
Conductor cross section stranded min.
0.2 mm
Conductor cross section stranded max.
2.5 mm
Stripping length
8 mm
Screw thread
M3
General
01/12/2015Page2/5
https://www.phoenixcontact.com/us/products/2814867
Signal conditioner-MCR-FL-C-UI-2UI-DCI-NC-2814867
Technical data
General
No. of channels
Maximum transmission error
0.15 % (of final value)
Transmission error, typical
0.05 % (of final value)
Maximum temperature coefficient
< 0.015 %/K
Temperature coefficient, typical
0.0075 %/K
Limit frequency (3 dB)
30 Hz
Step response (10-90%)
12 ms
Protective circuit
Transient protection
Test voltage, input/output/supply
1.5 kV (50 Hz, 1 min.)
Color
green
Housing material
Polyamide PA non-reinforced
Mounting position
any
Conformance
CE-compliant
UL, USA / Canada
Class I, Div. 2, Groups A, B, C, D or Non-Hazardous Locations
Classifications
eCl@ss
eCl@ss 4.0
27210120
eCl@ss 4.1
27210120
eCl@ss 5.0
27210120
eCl@ss 5.1
27210120
eCl@ss 6.0
27210120
eCl@ss 7.0
27210120
eCl@ss 8.0
27210120
ETIM
ETIM 2.0
EC001485
ETIM 3.0
EC001485
ETIM 4.0
EC001485
ETIM 5.0
EC001485
UNSPSC
UNSPSC 6.01
30211506
UNSPSC 7.0901
39121008
UNSPSC 11
39121008
UNSPSC 12.01
39121008
UNSPSC 13.2
39121008
01/12/2015Page3/5
https://www.phoenixcontact.com/us/products/2814867
Signal conditioner-MCR-FL-C-UI-2UI-DCI-NC-2814867
Approvals
Approvals
Approvals
UL Recognized / cUL Recognized / GOST / cULus Recognized
Ex Approvals
UL Listed / cUL Listed / cULus Listed
Approvals submitted
Approval details
UL Recognized
cUL Recognized
GOST
cULus Recognized
Drawings
01/12/2015Page4/5
https://www.phoenixcontact.com/us/products/2814867
Signal conditioner-MCR-FL-C-UI-2UI-DCI-NC-2814867
Dimensioned drawing
99
Circuit diagram
OUT
17,5
OUT I2 1
OUT U2 2
GND 2 3
114,5
A
D
IN I 4
IN U 5
GND 3 6
OUT
7 OUT I1
8 OUT U1
9 GND 1
+24V DC
GND 4
12 GND 4
10
A
D
11
IN
Application drawing
0...20mA
24V
0...20mA
IN
OUT 2
I2
U2
GND 3
GND 2
POWER
MCR-FL-C-UI-2UI-DCI
OUT 1
I
POWER
+24V
U1
GND 4
11
GND 1
GND 4
12
10
0...10V
15m3
24V
Application example: - Level measurement with subsequent signal multiplication
1 = filling level sensor
2 = control
3 = mains voltage
Phoenix Contact 2015 - all rights reserved
http://www.phoenixcontact.com