500 / 501
CONFIGURABLE CONTROLLERS
Main applications
l Plastics extrusion lines and
injection moulding machines
l Polymerisation plant for
synthetic fibre production
l Climatic chambers and test
benches
l Chemical and pharmaceutical
industries
l Food processing
l Packaging machinery
l Wood working machines
l Polyuretan machines
l Mould cooling units
l Industrial ovens
l Presses for rubber
Main features
l Inputs for thermocouples and
resistance thermometers completely
configurable from the faceplate
l Settable Offset function for input signal
l Relay, logic or continuous control
output
l Loop Break Alarm for open circuit load
or shortcircuit probe
l Alarm with configurable PD action for
cooling
l Self tuning, Auto tuning, Soft-start,
bumpless Man/Auto function
GENERAL
Microprocessor controller in 48x48 (1/16
DIN) format manufactured with SMT.
The instruments have an operator interface made up of 3 keys, a double 3-digit
(500) or 4-digit (501) display and 3 indicator LEDs, protected by a Lexan membrane to IP54.
The input section for the measured variable offers the choice of different sensor
types:
Thermocouples type J, K, N, S, R, T
Resistance Thermometer Pt100 (3-wire)
Linear inputs:
0-50mV, 10-50mV faceplate configurable
2-10V, 0-10V, 0-20mA, 4-20mA with
external shunt.
The instruments have two relay outputs
(5A, 250Vac with cosj = 1) or static PNP
(24Vdc, 20mA).
The first output is changeover and is
dedicated to the control output.
The second is a programmable alarm.
In alternative to the relay control output,
it is possible to have an analogue output
0-20mA, 4-20mA or 0-10V, 2-10V.
The programming of the instrument has
increasing levels of complexity and the
various parameters are grouped in three
different layers.
With increasing value of the programmable protection code, it is possible to place
lower limits on the access of the operator
to modify the configuration parameters.
A hardware jumper removes the possibility to enter into the configuration.
TECHNICAL DATA
INPUTS
Accuracy 0,5% f.s. 1digit.
Sampling time 120msec.
TC - Thermocouple
for 500 instrument
J (Fe-CuNi) 0...800C / 32...999F
K (NiCr-Ni) 0...999C / 32...999F
N (NiCrSi-NiSi) 0...999C / 32...999F
S (Pt10Rh-Pt) 0...999C / 32...999F
R (Pt13Rh-Pt) 0...999C/32...999F
T (Cu-CuNi) -100...400C / -148...752F
for 501 instrument
J (Fe-CuNi) 0...800C / 32...1472F
K (NiCr-Ni) 0...1300C / 32...1999F
N (NiCrSi-NiSi) 0...1300C / 32...1999F
S (Pt10Rh-Pt) 0...1600C / 32...1999F
R (Pt13Rh-Pt) 0...1600C/32...1999F
T (Cu-CuNi) -100...400C / -148...752F
Configured from the faceplate.
The error on the ambient temperature
compensation is 0,05C for every C
variation.
Over and under range, erroneous connection and open circuit probe messages.
RTD 2/3-wires
for 500 instrument
Pt100 -19.9...99,9C / -19,9...99,9F
Pt100 -199...400C / -199...752F
for 501 instrument
Pt100 -199,9...199,9C / -199,9...199,9F
Pt100 -200...400C/ -328...752F
DC - Linear
0...50mV, 10...50mV
Input impedance >1M.
To be used only with external shunt on the
controller for 0...10V, 0/4...20mA signals.
OUTPUTS
Main output (MAIN) with direct action (heating) / inverse action (cooling).
Relay
Rated at: 5A/250Vac a cosj=1
(3,5A a cosj=0,4).
Spark suppression on the NO contact
(order code: R0)
Logic
22Vdc, Rout=470 (20mA, max 12V)
Protected against inverse polarity and
shortcircuit.
(order code D2)
from the faceplate:
- Proportional band 0,0...99,9% f.s.
- Integral time 0,0...99,9 min
- Derivative time 0,0...9,99 min
(0,0...19,99 min)
- Reset power (proportional band
position) 0...100%
- Hysteresis (only for On/Off control)
-199...999 (-999...1999) digit.
- Soft-start (gradual increase of main
output power over a predetermined time
on switch on) 0...99,9 min
- Manual reset (correction of the offset
after setting) -199...999 digit (-999...1999)
- Offset (setting a difference between the
actual measurement of the input probe
and the value read by the controller)
-199...300 (-300...300) digit.
- Automatic/Manual function with
Bumpless transfer between manual and
automatic. Manual power stored.
- Automatic power ON and power OFF to
disactivated the instrument.
Hysteresis for the alarm setpoints is
configurable from the faceplate in the
range:
-199...999 (-999...1999) digit
WEIGHT
250g
ALARMS
Continuous
0...20mA or 4...20mA on a maximum resistance of 500 configurable as 0...10V
with 500 load impedance.
Load resistance 47k.
1 alarm, settable as absolute, deviation
or symmetrical deviation alarm with
respect to the control setpoint with
configurable mode (Hi or Lo).
The alarm point may be set anywhere
within the configured scale.
POWER SUPPLY
Alarm (AL) with PD action with
Standard: 100...240Vac/dc 10%
configurable parameters:
on request: 11...27Vac/dc 10%
Proportional band is set for the
50/60Hz, max. 6VA
hysteresis -199...999 (-999...1999) digit.
Protection by internal fuse not serviceable
- Derivative time 0,0...9,99 (0,0...19,99) min.
by the user.
- Cycle time 1...200sec (0 for On/Off alarm).
AMBIENT CONDITIONS
Alarm output can be associated to LBA
Working temperature: 0...50C
function for open circuit load or shortcirStorage temperature: -20...70C
cuit probe.
Humidity: 20...85%Ur non condensing
LBA (Loop Break Alarm) function alarm.
Intervention time and power output in
CONTROL
the alarm condition are configurable from
On/Off, P, PD, PID either for heating or
the faceplate.
cooling, with parameters configurable
FACEPLATE DESCRIPTION
A - Input variable display,
3 digit (500), 4 digit (501), green digits h. 10mm
B - Display of entered data
3 digit (500), 4 digit (501), green digits h. 10mm (500), 8mm (501)
C - Function key
D - Raise key
E - Lower key
F - Main output indication, green led
G - Alarm output indication, red led
B
F
C
A
B
IP54 faceplate protection
DIMENSIONS AND CUT-OUT
59
70
48
48
70
45
45
100
10
Dimensions: 48x48mm depth 100mm
CONNECTION DIAGRAM
NC
OUT1
(MAIN)
OUT2
(AL)
C
NO
PWR
SUPPLY
TC
Apply users manual warnings for a correct installation
Pt100
3-wires
Pt100 2-wires
ORDER CODE
MODEL
500
500
501
501
OUTPUT
Relay
R0*
Logic
D2
DC voltage
DC current
ALARMS
1 relay alarm
R0*
1 logic alarm
D2
POWER SUPPLY
11...27Vac/dc
100...240Vac/dc
1*
(*) Standard model
STANDARD CONFIGURATION
HW and SW
- With Hw/Sw configuration
protection
Setpoint = 400
AL = 100
Pb = 1,0%
rSt = 0
Ct = 20sec
PSt = 0%
S.tu = 0
Lb.t = 0min
Lb.P = 25%
It = 4,0min
dt = 1,0min
SOF = 0
Hy1 = 1
Pro = 19
AL = 11 (=1)
Out = 0
Typ = 0
Ct.a = 20 sec
dt.A = 1,00 min
oFt = 0
LO.S = 0
HI.S = 800
brd = 4 (mod. 500);
6 (mod. 501)
GEFRAN spa reserves the right to make any kind of design or functional modification at any moment without prior notice
In conformity to ECC 89/336/CEE and 73/23/CEE with reference to standards:
GEFRAN spa via Sebina, 74 - 25050 Provaglio dIseo (BS)
Tel. 03098881 - fax 0309839063 - Internet: http://www.gefran.it
cod. 80291 - 06/99
- EN 50082-2 (immunity in industrial environment) - EN 50081-1 (emission in residential environment) - EN 61010-1 (safety)