061/03.
98
RE 29 061/09.00
RE 29 061/09.00
Replaces: 06.00
4/2 and 4/3 proportional directional valves
directly controlled, with electrical
position feedback
Types 4WRE and 4WREE
H/A/D 5881/97
Nominal sizes 6 and 10
Series 2X
Maximum operating pressure 315 bar
Maximum flow 80 L/min (NS 6)
Maximum flow 180 L/min (NS 10)
H/A/D 5732/97
Type 4WRE 6 ...-2X/G24K4/V with plug-in connectors and
associated control electronics (separate order)
Type 4WREE 10 ...-2X/G24K31/A1V
With integrated control electronics
Overview of contents
Contents
Features
Ordering details
Preferred types
Symbols
Function, section
Technical data
Control electronics
Electrical connections
Characteristic curves
Unit dimensions
4WRE; 4WREE
Features
Page
1
2
3
3
4
5 and 6
6 to 8
6
9 to 15
16 and 17
Directly controlled proportional directional valve for the control of
the direction and magnitude of a flow
Actuation is by proportional solenoids with central thread and
removable coil
Electrical position feedback
For subplate mounting:
Porting pattern to DIN 24 340 form A, ISO 4401 and
CETOP-RP 121 H
Subplates to catalogue sheets RE 45 052 and RE 45 054
(separate order), see pages 16 and 17
Spring centred control spool
Type 4WREE, integrated valve electronics with interface A1 or F1
Control electronics for type 4WRE:
Digital amplifier VT-VRPD-2-1X/V0/0 in Eurocard format
(separate order), see page 6
Analogue amplifier VT-VRPA2-.-1X in Eurocard format
(separate order), see page 6
1/18
061/03.98
RE 29 061/06.00
Ordering details
4WRE
Without integrated
control electronics 1)
With integrated
control electronics
2X / G24
= No code
=E
Nominal size 6
Nominal size10
=6
= 10
A B
Symbols
a
P T
=E
E1-
=V
= W
W1-
A B
a
0
P T
= EA
Further details
in clear text
V=
FKM rectangular rings,
suitable for mineral oils
(HL, HLP) to DIN 51 524
Interface A1 or F1 for WREE:
A1 =
Command value input 10 VDC
F1 =
Command value input 4 to 20 mA
Electrical connection for WRE
K4 =
With component plug DIN 43 650-AM2
Without plug-in connector
(solenoid, position transducer)
Plug-in connector separate order
see page 6
Electrical connection for WREE
K31 = With component plug to E DIN 43 563-AM6-3
Without plug-in connector
Plug-in connector separate order
see page 7
G24 =
Power supply voltage 24 VDC
2X =
Series 20 to 29
(20 to 29: unchanged installation and connection dimensions)
Nominal flow at a valve pressure differential p = 10 bar
NS6
08 =
8 L/min
16 =
16 L/min
32 =
32 L/min
NS10
25 =
25 L/min
50 =
50 L/min
75 =
75 L/min
= WA
With symbols E1- and W1-:
B T: qV/2
P A: qV max
P B: qV/2
A T: qV max
Note:
For spools W and WA there is, in the neutral position, a
connection between A to T and B to T with approx. 3 %
of the relevant nominal cross-section.
1)
See page 6
Rexroth Hydraulics
2/18
4WRE; 4WREE
RE
RE 29
29 061/12.98
061/03.98
Preferred types
NS 6
NS 10
Material No.
Type WRE
Material No.
Type WRE
00933478
00954092
00926366
00954093
00954094
00941264
00944121
00933480
00954095
00954096
00954097
00954098
00954099
4WRE 6 E08-2X/G24K4/V
4WRE 6 E16-2X/G24K4/V
4WRE 6 E32-2X/G24K4/V
4WRE 6 E1-16-2X/G24K4/V
4WRE 6 E1-32-2X/G24K4/V
4WRE 6 W08-2X/G24K4/V
4WRE 6 W16-2X/G24K4/V
4WRE 6 W32-2X/G24K4/V
4WRE 6 W1-16-2X/G24K4/V
4WRE 6 W1-32-2X/G24K4/V
4WRE 6 V08-2X/G24K4/V
4WRE 6 V16-2X/G24K4/V
4WRE 6 V32-2X/G24K4/V
00954100
00954101
00954102
00954103
00954104
00954105
00954106
00954107
00954113
00954114
00954115
00954116
00954117
4WRE 10 E25-2X/G24K4/V
4WRE 10 E50-2X/G24K4/V
4WRE 10 E75-2X/G24K4/V
4WRE 10 E1-50-2X/G24K4/V
4WRE 10 E1-75-2X/G24K4/V
4WRE 10 W25-2X/G24K4/V
4WRE 10 W50-2X/G24K4/V
4WRE 10 W75-2X/G24K4/V
4WRE 10 W1-50-2X/G24K4/V
4WRE 10 W1-75-2X/G24K4/V
4WRE 10 V25-2X/G24K4/V
4WRE 10 V50-2X/G24K4/V
4WRE 10 V75-2X/G24K4/V
Material No.
Type WREE
Material No.
Type WREE
00912156
00920567
00907114
00915686
00928553
00923000
00925657
00911004
00939627
00913359
00909367
00907440
00911681
00933073
00927231
00927230
00933076
00927232
00933074
00931371
00927233
00933077
00927234
00933075
00927235
00924607
4WREE 6 E08-2X/G24K31/A1V
4WREE 6 E16-2X/G24K31/A1V
4WREE 6 E32-2X/G24K31/A1V
4WREE 6 E1-16-2X/G24K31/A1V
4WREE 6 E1-32-2X/G24K31/A1V
4WREE 6 W08-2X/G24K31/A1V
4WREE 6 W16-2X/G24K31/A1V
4WREE 6 W32-2X/G24K31/A1V
4WREE 6 W1-16-2X/G24K31/A1V
4WREE 6 W1-32-2X/G24K31/A1V
4WREE 6 V08-2X/G24K31/A1V
4WREE 6 V16-2X/G24K31/A1V
4WREE 6 V32-2X/G24K31/A1V
4WREE 10 E25-2X/G24K31/A1V
4WREE 10 E50-2X/G24K31/A1V
4WREE 10 E75-2X/G24K31/A1V
4WREE 10 E1-50-2X/G24K31/A1V
4WREE 10 E1-75-2X/G24K31/A1V
4WREE 10 W25-2X/G24K31/A1V
4WREE 10 W50-2X/G24K31/A1V
4WREE 10 W75-2X/G24K31/A1V
4WREE 10 W1-50-2X/G24K31/A1V
4WREE 10 W1-75-2X/G24K31/A1V
4WREE 10 V25-2X/G24K31/A1V
4WREE 10 V50-2X/G24K31/A1V
4WREE 10 V75-2X/G24K31/A1V
Symbols
Type 4WRE...
Type 4WREE...
A B
A B
a
Type 4WRE...A...
A B
a
P T
P T
4WRE; 4WREE
Type 4WREE...A...
A B
G
P T
P T
3/18
Rexroth Hydraulics
RE 29 061/12.98
061/03.98
Function, section
The 4/2 and 4/3 proportional directional valves are directly controlled
components of subplate mounting design. They are operated by proportional solenoids with central thread and removable coil. The solenoids are optionally controlled by either external control electronics
(type WRE) or by integrated control electronics (type WREE).
Design:
The valve basically consists of:
Housing (1) with mounting face
Control spool (2) with compression springs (3 and 4)
Solenoids (5 and 6) with central thread
Position transducer (7)
Optional integrated control electronics (8)
The mechanical zero point adjustment (9) is accessible via the
Pg 13.5 and the electrical zero point is accessible via the Pg 7 (10)
(type 4WREE)
Functional description:
With the solenoids (5 and 6), de-energised, the control spool (2)
is held in the central position by the compression springs
(3 and 4)
Direct operation of the control spool (2) by energising one of the
proportional solenoids, e.g. control of solenoid "b" (6)
Movement of the control spool (2) to the left in proportion
to the electrical input signal
Connection from P to A and B to T via orifice like cross-sections
with progressive flow characteristics
De-energising of solenoid (6)
The control spool (2) is returned to the central position via the
compression spring (3)
In the de-energised condition the spool (2) is held in a mechanical centre
position by the solenoid return springs. This, for the spool symbol "V",
does not relate to the hydraulic centre position! When the electrical valve
closed loop control circuit is closed then the spool is positioned in the
hydraulic centre position.
"a"
"b"
A T B
(P)
11
1
10
10
11
Type 4WRE...-2X/G24
"a"
"b"
Type 4WREE...-2X/G24
Valve with 2 switching positions: (type 4WREA)
The function of this valve version is basically the same as that of the
valve with 3 switching positions. The 2 switching position valves are
however, only fitted with solenoid "a" (5). A plug (11) is fitted
in place on the 2nd proportional solenoid.
Rexroth Hydraulics
A T B
(P)
11
10
Note for type 4WRE-2X/G24:
Draining of the tank line is to be prevented. Taking the installation
conditions into account a back pressure valve is to be fitted (back
pressure approx. 2 bar).
4/18
4WRE; 4WREE
RE 29 061/09.00
061/03.98
Technical data (for applications outside these parameters, please consult us!)
General
NS 6
Installation
NS 10
Optional, preferably horizontal
Storage temperature range
20 to + 80
Ambient
4WRE
20 to + 70
temperature range
4WREE
20 to + 50
Weight
4WRE
kg
2.2
6.3
4WREE
kg
2.4
6.5
25
16
50
32
75
80
180
Hydraulic (measured at p = 100 bar, with HLP46 at 40 C 5 C)
Operating pressure
Ports A, B, P
bar
Up to 315
Port T
bar
Up to 210
Nominal flow qV nom at p = 10 bar
Max. permissible flow
L/min
L/min
Pressure fluid
Mineral oil (HL, HLP) to DIN 51 524,
further pressure fluids on request
Pressure fluid temperature range
C
mm2/s
Viscosity range
20 to + 80, preferably + 40 to + 50
20 to 380, preferably 30 to 46
Degree of contamination
Maximum permissible degree
of contamination to the
pressure is to NAS 1638
A filter is recommended
that has a minimum
retension rate of x 75
Class 9
x = 10
Hysteresis
0.1
Reversal span
0.05
Response sensitivity
0.05
10
Electrical
Command value signal
Voltage input "A1"
4WREE
Current input "F1"
mA
4 to 20
Solenoid coil resistance
2 to 3
Duty
100
Max. coil temperature
Up to 150
Valve protection to DIN 40 050
4WRE; 4WREE
IP 65 with fitted and secured plug-in connector
5/18
Rexroth Hydraulics
RE 29 061/09.00
061/03.98
Technical data (for applications outside these parameters, please consult us!)
Electrical (integrated electronics)
Supply voltage
Nominal voltage
VDC
24
4WREE
Lower limiting value
19
Upper limiting value
35
Amplifier power
Imax
1.8
consumption
Impulse current
Zero displacement
%/10 K
%/100 bar
0.15
0.1
Electrical (control electronics)
For 4WREE
For 4WRE
Amplifier in Eurocard format (separate order)
Note:
Integrated in the valve, see pages 7 and 8
digital
analogue
VT-VRPD-2-1X/V0/0 to catalogue sheet RE 30 125
VT-VRPA2-.-1X/V0 to catalogue sheet RE 30 119
For details regarding the environmental simulation test covering EMC (electro-magnetic compatibility), climate
and mechanical loading see RE 29 061-U (declaration regarding environmental compatibility).
Electrical connection
Type 4WRE (for external control electronics)
Connections on the plug-in connector
PE
To amplifier
27,5
36
Plug-in connector to DIN 43 650-AF2/Pg11
Solenoid a, colour grey
separate order under Material No. 00074683
Solenoid b, colour black
Separate order under Material No. 00074684
30
30
Connections on the plug connector
4
1
2 1
4 3
Signal ground
Supply ground
2
3
Signal
Supply
37
Pg7
7,8
23
15
16
Plug-in connector 4-pin Pg7-G4W1F
Separate order under Material No. 00023126
Connection cable:
Recommended: Up to 50 m cable length
type LiYCY 4 x 0.25 mm2
Only connect screen to PE on the supply side.
Rexroth Hydraulics
To amplifier
53
27,5
Inductive position transducer
Coil connections
To amplifier
PE
PE
PE
22,5
Connections on the component plug
6/18
4WRE; 4WREE
RE 29 061/03.98
061/09.00
Integrated control electronics for type 4WREE
Plug-in connector
Plug-in connector to E DIN 43 563-BF6-3/Pg11
Separate order under Material No. 00021267 (plastic version), for pin allocations see block circuit diagram on page 8
Angled form separate order under Material No. 00217845
6,511
27
91
Plug-in connector to E DIN 43 563-BF6-3/Pg13,5
Separate order under Material No. 00223890 (metal version)
AF
B
C
812
29
70
Component plug allocation
Contact
Allocation interface A1
Allocation interface F1
24 VDC (u(t) = 19,4 V to 35 V); Imax = 2 A
0V
Ref. potential actual value
reference contact F; Re > 50 k
reference contact F; Re < 10
Differential amplifier input
10 V com. value; Re > 50 k;
4...20 mA com. value; Re > 100
ref. potentional com. value
10 V act. value, (limiting load 5 mA)
PE
Connected with cooling body and valve housing
Supply voltage
Measurement output (act. value)
Actual value:
4...20 mA act. value,
load max. 300
A positive actual value (or 12 to 20 mA) at F and the reference potential at C results in a flow from P to A.
Command value: A positive command value (or 12 to 20 mA) at D and the reference potential at E results in a flow from P to A
and B to T.
A negative command value (or 4 to 12 mA) at D and the reference potential at E results in a flow from P to B
and A to T.
For a valve with 1 solenoid on side a (e.g. spool variants EA and WA) a positive command value (or 4 20 mA)
at D and the reference potential at E results in a flow from P to B and A to T.
Connection cable: Recommended: Up to 25 m cable length type LiYCY 7 x 0.75 mm2
Up to 50 m cable length type LiYCY 7 x 1.0 mm2
Outside diameter 6.5 to 11 mm
Only connect screen to PE on the supply side.
4WRE; 4WREE
7/18
Rexroth Hydraulics
RE 29 061/03.98
061/06.00
Integrated control electronics for type 4WREE
Block circuit diagram / connection allocation for the integrated valve electronics
Interface
Com. value
Differential
amplifier
U
Ramp
generator
Ref. potential
Act. value
Controller
Under voltage
recognition
Supply 24 V
voltage GND
A
B
PE
Power supply
U
+ Ui
0V
Ui
Oscillator
=
Demodulator
=
2)
3)
Zero point 3)
Sensitivity
1)
Interlock
Protective
conductor 1)
Note:
Act. value
U
Ref. potential
Valve
Integrated valve electronics
Position
tranducer
Electrical signals processed by control electronics (e.g. actual value) must not be used for switching off
safety-relevant machine functions!
(See also the European Standard "Safety requirements of fluid power systems and components
Hydraulics, EN 982!)
Connection (PE) is connected to the cooling body and the valve housing
Ramp is externally adjustable from 0 to 2.5 s; for Tup and Tdown
Zero point is externally adjustable
A
B
F
E
C
D
Rexroth Hydraulics
Reference
(Actual Value)
10 V/4 20 mA
(Diff.)
Reference
(Diff.)
Zero
4)
3)
Actual Valve
+24 V
0V
3)
2)
8/18
4WRE; 4WREE
061/03.98
RE 29 061/09.00
Characteristic curves for type 4WREE (measured with HLP46 at 40 C 5 C)
NS 6 and 10
Pressure-signal-characteristic curves (V spool), pS = 100 bar
NS 10
100
80
80
60
60
40
40
20
5
pL
pS in %
100
20
20
5
20
p
p L in %
S
NS 6
40
40
60
60
80
80
100
100
UE
in %
UEN
UE
in %
UEN
Leakage flow (with the spool in the central position)
Type 4WREE 10 V75
Type 4WREE 6 V32
2
Leakage flow in L/min
Leakage flow in L/min
50
100
150
200 210
250
300 315
50
100
150
200 210 250
300 315
Operating pressure in bar
Operating pressure in bar
4WRE; 4WREE
9/18
Rexroth Hydraulics
RE 29 061/09.00
061/03.98
Characteristic curves for type 4WREE (measured at p = 100 bar, with HLP46 at 40 C 5 C)
NS 6
8 L/min nominal flow at a 10 bar valve pressure differential
Flow in L/min
30
PA/BT
or
PB/AT
20
10
10
15 20
20
30
1
2
3
4
5
4
3
2
1
30
40
40
50
50
60
60
70
80
70
Command value in %
80
90
90
100
100
p
p
p
p
p
= 10 bar constant
= 20 bar constant
= 30 bar constant
= 50 bar constant
= 100 bar constant
V spool
E and W spools
16 L/min nominal flow at a 10 bar valve pressure differential
60
Flow in L/min
50
5
PA/BT
or
PB/AT
4
40
1
2
3
4
5
30
2
20
p
p
p
p
p
= 10 bar constant
= 20 bar constant
= 30 bar constant
= 50 bar constant
= 100 bar constant
10
10
15 20
20
30
30
40
50
40
50
60
60
70
80
70
Command value in %
80
90
100
90
100
E and W spools
V spool
32 L/min nominal flow at a 10 bar valve pressure differential
120
110
100
Flow in L/min
90
PA/BT
or
PB/AT
80
1
2
3
4
5
70
60
50
40
p
p
p
p
p
= 10 bar constant
= 20 bar constant
= 30 bar constant
= 50 bar constant
= 100 bar constant
30
20
10
0
15 20
10
20
30
30
40
40
50
50
60
60
70
70
Command value in %
80
V spool
80
90
100
90
100
E and W spools
p = Valve pressure differential (inlet pressure pP minus load pressure pL minus return pressure pT)
Rexroth Hydraulics
10/18
4WRE; 4WREE
RE 29 061/09.00
061/03.98
Characteristic curves for type 4WREE (measured at p = 100 bar, with HLP46 at 40 C 5 C)
NS 10
25 L/min nominal flow at a 10 bar valve pressure differential
80
5
PA/BT
or
PB/AT
70
60
Flow in L/min
4
50
3
40
2
30
1
2
3
4
5
p = 10 bar constant
p = 20 bar constant
p = 30 bar constant
p = 50 bar constant
p = 100 bar constant
20
10
10
0
15 20
20
30
30
40
50
40
50
60
60
70
Command value in %
50 L/min nominal flow at a 10 bar valve pressure differential
80
90
80
90
100 E and W spools
150
Flow in L/min
PA/BT
or
PB/AT
125
100
V spool
70
100
75
2
50
1
2
3
4
5
p = 10 bar constant
p = 20 bar constant
p = 30 bar constant
p = 50 bar constant
p = 100 bar constant
25
10
15 20
20
30
30
40
50
40
50
60
60
70
Command value in %
75 L/min nominal flow at a 10 bar valve pressure differential
300
275
Flow in L/min
250
225
70
80
80
90
90
100
100
E and W spools
PA/BT
or
PB/AT
V spool
Note:
Power limitations on page 15
are to be taken into account!
200
175
150
125
100
1
2
3
4
5
p = 10 bar constant
p = 20 bar constant
p = 30 bar constant
p = 50 bar constant
p = 100 bar constant
75
50
25
0
15 20
10
20
30
30
40
40
50
50
60
60
70
Command value in %
70
80
80
90
90
100
100
V spool
E and W spools
p = Valve pressure differential (inlet pressure pP minus load pressure pL minus return pressure pT)
4WRE; 4WREE
11/18
Rexroth Hydraulics
RE 29 061/09.00
061/03.98
Transient function with a stepped form of electrical input signal for type 4WREE
(measured with HLP46 at 40 C 5 C)
NS 6
Signal change in %
100
0 100
pS = 10 bar
90
Strokle in %
80
0 75
70
60
0 50
50
40
30
0 25
20
10
0
10
20
40
30
10
20
30
Time in ms
Frequency response characteristic curves for type 4WREE (measured with HLP46 at 40 C 5 C)
NS 6
270
3
5
225
10
180
15
135
20
90
25
45
30
1
10
20
50
100
200
Phase angle in
Amplitude relationship in dB
315
Frequency in Hz
Signal 100 %
pS = 10 bar
Signal 25 %
Signal 10 %
Rexroth Hydraulics
12/18
4WRE; 4WREE
RE 29 061/09.00
061/03.98
Performance limits for type 4WREE (measured with HLP46 at 40 C 5 C)
NS 6
Nominal flow 8 L/min
50
7
6
5
4
3
Flow in L/min
40
30
PA/BT
or
P B /A T
2
20
1
10
50
100
150
200
250
300 315
Valve pressure differential in bar
Flow in L/min
Nominal flow 16 L/min
110
100
90
80
70
60
50
40
30
20
10
0
7
6
5
4
P A / B T
or
P B /A T
3
2
1
50
100
150
200
250
300 315
Valve pressure differential in bar
Flow in L/min
Nominal flow 32 L/min
7
120
110
100
90
80
70
60
50
40
30
20
10
0
P A / B T
or
P B /A T
6
5
4
3
2 Performance limit
1
50
100
150
200
250
300 315
Valve pressure differential in bar
1
2
3
4
5
6
7
4WRE; 4WREE
Command value
Command value
Command value
Command value
Command value
Command value
Command value
13/18
=
=
=
=
=
=
=
40 %
50 %
60 %
70 %
80 %
90 %
100 %
Rexroth Hydraulics
RE 29 061/09.00
061/03.98
Transient function with a stepped form of electrical input signal for type 4WREE
(measured with HLP46 at 40 C 5 C)
NS 10
Signal change in %
100
0 100
pS = 10 bar
90
Stroke in %
80
0 75
70
60
0 50
50
40
30
0 25
20
10
0
10
20
40
30
10
20
30
Time in ms
Frequency response characteristic curves for type 4WREE (measured with HLP46 at 40 C 5 C)
NS 10
0
3
5
270
10
180
15
135
20
90
25
45
30
225
10
20
50
100
200
Phase angle in
Amplitude relationship in dB
315
Frequency in Hz
Signal 100 %
pS = 10 bar
Signal 25 %
Signal 10 %
Rexroth Hydraulics
14/18
4WRE; 4WREE
RE 29 061/09.00
061/03.98
Performance limits for type 4WREE (measured with HLP46 at 40 C 5 C)
NS 10
Flow in L/min
Nominal flow 25 L/min
1
130
120
110
100
90
80
70
60
50
40
30
20
10
0
50
100
150
200
PA/BT
or
PB/AT
250
Valve pressure differential in bar
Flow in L/min
Nominal flow 50 L/min
170
160
150
140
130
120
110
100
90
80
70
60
50
40
30
20
10
0
PA/BT
or
P B /A T
1
50
100
150
200
250
Valve pressure differential in bar
Flow in L/min
Nominal flow 75 L/min
240
220
200
180
160
140
120
100
80
60
40
20
0
P A / B T
or
P B /A T
50
100
150
200
250
Valve pressure differential in bar
1 Command value
4WRE; 4WREE
15/18
100 %
Rexroth Hydraulics
RE 29 061/06.00
061/03.98
Unit dimensions: NS 6
12
15
Type 4WRE
(Dimensions in mm)
b
23
47
42
85,5
75
13,5
8,5
44
68
69
203
262
11
12
10
42
47
113,5
Type 4WREE
23
75
13,5
8,5
44
68
69
203
72
40,5
15
T
P
Subplates to catalogue sheet RE 45 052 and valve fixing screws
must be ordered separately.
Subplates:
G341/01 (G1/4)
G342/01 (G3/8)
G502/01 (G1/2)
Valve fixing screws:
4 off M5 x 50 DIN 912-10.9; MA = 8.9 Nm
1
2
3
4
Valve housing
Proportional solenoid "a" with inductive position transducer
Proportional solenoid "b"
Plug-in connector "A", colour grey;
separate order, see page 6
5 Plug-in connector "B", colour black;
separate order, see page 6
6 Plug-in connector for inductive position transducer;
separate order, see page 6
Rexroth Hydraulics
47
31,75
31
0,75
262
T
B
P
13
0,01/100mm
R max 4
Required surface finish of
mating piece
7 Plug for valves with one solenoid
(2-switching positions), versions EA or WA
8 R-ring 9.81 x 1.5 x 1.78 (ports A, B, P, T)
9 Space required to remove plug-in connector
10 Integrated control electronics
11 Plug-in connector to E DIN 43 563-BF6-3/Pg11
(separate order, see page 7)
12 Name plate
13 Machined valve mounting surface and location of the
connections to DIN 24 340 form A, ISO 4401 and
CETOP-RP121H
16/18
4WRE; 4WREE
061/03.98
RE 29 061/06.00
Unit dimensions: NS 10
6
1 8 12 7
15
Type 4WRE
(Dimensions in mm)
113,5
a
30
40
72,5
12
19
70
107,5
92
269,5
365
12
10
11
a
30
40
72,5
139
Type 4WREE
12
19
70
107,5
92
269,5
13
94
365
54
TB
TA
54
Subplates to catalogue sheet RE 45 054 and valve fixing screws
must be ordered separately.
Subplates:
G66/01 (G3/8)
G67/01 (G1/2)
G534/01 (G3/4)
Valve fixing screws:
4 off M6 x 40 DIN 912-10.9; MA = 15.5 Nm
1 Valve housing
2 Proportional solenoid "a" with inductive position transducer
3 Proportional solenoid "b"
4 Plug-in connector "A", colour grey;
separate order, see page 6
5 Plug-in connector "B", colour black;
separate order, see page 6
4WRE; 4WREE
19
0,01/100mm
R max 4
46
64
A P B
72
13
20
P
A
TA
TB
Required surface finish of
mating piece
6 Plug-in connector for inductive position transducer;
separate order, see page 6
7 Plug for valves with one solenoid
(2-switching positions), versions EA or WA
8 R-ring 13.0 x 1.6 x 2.0 (ports A, B, P, TA, TB)
9 Space required to remove plug-in connector
10 Integrated control electronics
11 Plug-in connector to E DIN 43 563-BF6-3/Pg11;
separate order, see page 7
12 Name plate
13 Machined valve mounting surface and location of the connections
to DIN 24 340 form A, ISO 4401 and CETOP-RP121H
17/18
Rexroth Hydraulics
RE 29 061/03.98
Notes
Mannesmann Rexroth AG
Rexroth Hydraulics
Mannesmann Rexroth Limited
D-97813 Lohr am Main
Jahnstrae 3-5 D-97816 Lohr am Main
Telefon 0 93 52 / 18-0
Telefax 0 93 52 / 18-23 58 Telex 6 89 418-0
eMail product.support@rexroth.de
Internet www.rexroth.com
Cromwell Road, St Neots,
Cambs, PE19 2ES
Tel: 0 14 80/22 32 56
Fax: 0 14 80/21 90 52
E-mail: info@rexroth.co.uk
Rexroth Hydraulics
The specified data is for product description
purposes only and may not be deemed to be
guaranteed unless expressly confirmed in the
contract.
All rights reserved Subject to revision.
18/18
4WRE; 4WREE