GE Healthcare

MAC 600
Resting ECG

Technical Specifications

Instrument Type
Microprocessor augmented automatic electrocardiograph; 10-leadwire, 12-lead simultaneous acquisition with programmable
lead configuration.
Processing
ECG interpretation:

Marquette 12SL ECG Analysis Program for Adults and Pediatrics

Computerized measurements:

12-lead analysis

ECG analysis frequency:

500 samples/second (sps)

Digital sampling rate:

2,000 samples/second/channel

ECG on-screen preview:

On-screen preview of acquired 10-second ECG waveform and optional 12SL measurement and
interpretation

Acquisition mode:

Pre-acquisition or post-acquisition, provide 10 seconds of instantaneous ECG acquisition

Dynamic range:

AC Differential 5mV, DC offset 300 mV

Resolution:

4.88 V/LSB @ 500 sps

Frequency response:

3 dB @ 0.01 to 150 Hz

Low cut-off frequency:

0.01 Hz, 0.02 Hz, 0.16 Hz or 0.32 Hz (-3 dB limits)

High cut-off frequency:

Configurable at 20 Hz, 40 Hz, 100 Hz or 150 Hz

Adaptive AC filter:

47 Hz to 53 Hz when set to 50Hz, 57 Hz to 63 Hz when set to 60 Hz

Common mode rejection:

>100 dB (with AC filter switched on)

Input impedance:

>10M @ 10 Hz, defibrillator protected

Patient leakage:

<10 A

Special acquisition functions:

Disconnected lead detection except RL, excessive AC noise, baseline wander


and muscle tremor messages

Heart rate meter:

30 to 300 BPM 10% or 5 BPM, whichever is greater. Heart rates outside this range will not be
displayed

Start-up time:

Less than 7 seconds

Patient Information
Supported patient information:

Patient ID, secondary ID, age, date of birth, gender.


Alphanumeric entry in T9 type for patient ID and secondary ID.

Display
Display type:

4.3 inch (110 mm) diagonal, TFT LCD with LED graphics backlit (color optional)

Display resolution:

480 X 272 pixels with scrolling waveform

Display data:

Heart rate, patient ID, clock, battery power indicator, waveforms, lead labels, speed, gain and
filter settings, warning messages, information messages, prompts. 12-leads standard display.

Writer
Writer technology:

Thermal dot array

Writer speed:

5, 12.5, 25, & 50 mm/s

Number of traces:

3 leads + 1 rhythm or 3 leads; user selectable

Writer sensitivity/gain:

2.5, 5, 10, 20, 10/5 (split calibration) mm/mV

Writer speed accuracy:

5%

Writer amplitude accuracy:

5%

Writer resolution:

Horizontal 40 dots/mm @ 25 mm/s, 8 dots/mm vertical

Paper type:

Thermal. Z-fold perforated, 80 mm width, 280 sheets/pack. Roll paper 15.7 m.

Keyboard
Type:

Type Membrane keyboard with tactile feedback

Software Standard
Resting ECG mode:

Records and prints 12-lead resting ECGs with 10-second duration as a standard feature

Hookup Advisor :

Provides visual indication of signal quality

Multi-language support:

Supports 16 languages

Software Options
Measurement:

Supports measurement with Marquette 12SL ECG Analysis Program

Measurement and
interpretation:

Supports measurement and interpretation with Marquette 12SL ECG Analysis Program

Color:

Color display

External storage:

200 ECGs in external memory (SD card)

Transmission:

ECG data transmission via serial cable

XML format:

ECG storage in XML format

PDF format:1

ECG storage in PDF format

Communication (optional)
MUSE Cardiology Information System Compatible
Serial cable:

ECG transmission to MUSE Cardiology Information System

Serial cable:

ECG transmission in XML format

SD card interface:

Compatible with MUSE v7

CardioSoft Interface
SD card interface:

Compatible with Cardiosoft V6.51 or above

Serial cable:

ECG transmission over serial line to CardioSoft V6.61 or above

Storage (optional)
ECG storage format:

GE storage format for MUSE and CardioSoft.


XML storage format.
PDF storage format.

PDF file name format:

User-configurable file name, which includes patient ID, secondary ID, date of birth,
ECG recording date and time

Report Formats

Thermal printer report formats

4 by 2.5s
4 by 2.5s + 1 rhythm lead
4 by 3s
4 by 10s
Autorhythm (10-second ECG data for 3 leads)
Printing of 4 by 10s or Autorhythm for abnormal ECG
Continuous 3-channel rhythm

PDF report format


(A4 format):

4 by 2.5s
4 by 2.5s + 1 rhythm lead
2 by 5s
2 by 5s + 1 rhythm lead
2 by 5s @ 50mm/s
4 by 10s
Autorhythm (12-lead)

Accessories
IEC/AHA leadwire and electrode adaptor sets (user-selectable)
10-lead patient cable (user-selectable replaceable leads or fixed leads cables)
Electrodes (disposable or reusable, user-selectable)
Country-specific power cords
Z-fold and Roll paper
Electrode cream 250 ml/tube
Electrical
Power supply:

External AC/DC adaptor or battery operation

External Adaptor Specifications


Input voltage:

100 to 240 VAC 10%

Input current:

Maximum 0.6A @ 90 VAC, 0.3A @ 240 VAC

Input frequency:

50 to 60 Hz 3Hz

Output voltage:

12V 5%

Battery Specifications
Battery type:

Replaceable and rechargeable, Lithium Ion

Battery capacity:

7.2V typical, 2.25 AH 10%


360 minutes of continuous operation without recording or
250 ECGs in 2.5 X 4 format at 25 mm/S and 10 mm/mV or
100 minutes continuous rhythm print at 25 mm/S and 10 mm/mV.

Battery charge time:

Approximately 3 hours from total discharge (with display off)

Physical Specification
Height:

81 mm

Width:

263 mm

Depth:

208 mm

Weight:

1.2 Kg including battery, without paper

ECG storage in PDF format is not supported in Russian language.

Environmental Specification
Temperature
Operating

5C to 40C

Transport/storage:

-15C to 50C

Humidity
Operating:

25% to 95% RH non-condensing

Transport/storage:

25% to 95% RH non-condensing

Pressure
Operating:

700 to 1060 hPA

Transport/storage:

500 to 1060 hPA

Certification
Class II, type CF defibrillator proof
UL 60601-1 Medical Electrical Equipment, part 1: General Requirements for Safety
CAN/CSA C22.2 No. 601.1 General Requirements for Safety
CE marking for Council Directive 93/42/EEC concerning medical devices
IEC 60601-1 General Requirements for Safety
IEC 60601-1-1 General Requirements for Safety Medical Electrical systems
IEC 60601-2-25 Particular Requirements for the Safety of Electrocardiographs
IEC 60601-2-51 Particular Requirements for Safety, including essential performance, of recording and analyzing single channel
and multi channel electrocardiographs
IEC 60601-1-2 General Requirements for Safety Electromagnetic Compatibility
IEC 60601-1-4 General Requirements for Safety Programmable electrical medical systems
IEC 60601-1-6 General Requirements for basic safety and essential performance Collateral Standard: Usability-Edition 2.0
Meets applicable AAMI EC-11 requirements and AAMI EC 13 (Clause 4.2.7 only)

2012 General Electric Company All rights reserved.

About GE Healthcare

General Electric Company reserves the right to make changes


in specifications and features shown herein, or discontinue
the product described at any time without notice or obligation.
Contact your GE Representative for the most current information.

GE Healthcare provides transformational medical


technologies and services that are shaping a
new age of patient care. Our broad expertise in
medical imaging and information technologies,
medical diagnostics, patient monitoring systems,
drug discovery, biopharmaceutical manufacturing
technologies, performance improvement and
performance solutions services helps our customers
to deliver better care to more people around the
world at a lower cost. In addition, we partner with
healthcare leaders, striving to leverage the global
policy change necessary to implement a successful
shift to sustainable healthcare systems.

GE and GE Monogram are trademarks of General Electric


Company.
MAC and Marquette and MUSE are registered trademarks of
General Electric Company.
12SL, CardioSoft and HookUp Advisor are trademarks of General
Electric Company.
GE Healthcare, a division of General Electric Company

GE Healthcare
9900 Innovation Drive
Wauwatosa, WI 53226
U.S.A.
www.gehealthcare.com

Our healthymagination vision for the future invites


the world to join us on our journey as we continuously
develop innovations focused on reducing costs,
increasing access and improving quality and
efficiency around the world.

DOC0444964 rev4