Laboratory
Electrical Research and Development Association, ERDA Road, GIDC,
Makarpura, Vadodara, Gujarat
Accreditation Standard
ISO/IEC 17025: 2005
Discipline
Certificate Number
Last Amended on
Electro-Technical Calibration
C-0062
14.07.2014
Quantity Measured/
Instrument
Range / Frequency
Issue Date
Valid Until
Page
*Calibration Measurement
Capability ()
28.06.2014
27.06.2016
1 of 12
Remarks
SOURCE
1.
DC VOLTAGE
1 mV to 10 mV
10 mV to 1000 V
0.49% to 0.01%
0.01% to 0.009%
Using Universal calibration
system Wavetek 9100 / FLUKE
5500A by Direct Method
2.
DC CURRENT
1 A to 320 mA
320 mA to 20 A
20 A to 1000 A
1.38% to 0.03%
0.03% to 0.2%
0.2% to 0.4%
Using Universal calibration
system Wavetek 9100 / FLUKE
5500A with Current Coils by
Direct Method
3.
RESISTANCE
10
100
1 m
10 m
100 m
0.07%
0.02%
0.02%
0.02%
0.02%
Using Standard Resistors
Ohm Lab/Tettex / YEW
1
1 to 40
40 to 40 k
40 k to 40 M
0.05%
0.05% to 0.1%
0.1% to 0.02%
0.03% to 0.18%
Using Universal Calibration
System Wavetek 9100 /fluke 5500
40 M to 100 M
100 M to 10 G
10 G to 1
0.18% to 0.3%
0.3% to 1.51%
1.51% to 2.7%
20 Hz to 100 kHz
10 mV to 300 mV
0.49% to 0.06%
4.
AC VOLTAGE
Avijit Das
Program Manager
Using Megohm Decade Box
Tinsley By Direct Method
Using Universal Calibration
System Wavetek 9100 / FLUKE
5500
Bibin Philip
Convenor
Laboratory
Electrical Research and Development Association, ERDA Road, GIDC,
Makarpura, Vadodara, Gujarat
Accreditation Standard
ISO/IEC 17025: 2005
Discipline
Certificate Number
Last Amended on
Electro-Technical Calibration
C-0062
14.07.2014
Quantity Measured/
Instrument
5.
AC CURRENT
6.
FREQUENCY/
TIME
7.
OSCILLOSCOPE
Amplitude
Bandwidth
Avijit Das
Program Manager
Range / Frequency
Issue Date
Valid Until
Page
*Calibration Measurement
Capability ()
28.06.2014
27.06.2016
2 of 12
Remarks
20 Hz to 10 kHz
300 mV to 100 V
0.1% to 0.06%
by Direct Method
10 kHz to 100 kHz
300 mV to 100 V
0.06% to 0.55%
50 Hz to 10 kHz
100 V to1000 V
0.06% to 0.2%
50 Hz
10 V to 115 V
115V to 480V
480V to 575V
0.04%
0.008%
0.04%
Using Electrical Power Standard
Master / FLUKE 6100A/ 6105A
by Direct Method
50 Hz to 5 kHz
100 A to 300 mA
300 mA to 3 A
0.1% to 0.15%
0.04% to 0.16%
Using Universal Calibration
System Wavetek 9100 / FLUKE
5500 by Direct Method
50 Hz to 1 kHz
3 A to 10 A
0.04% to 0.29%
50 Hz
0.1A to 60A
60A to 1000 A
0.008% to 0.015%
0.015% to 0.24%
10 Hz to 10 MHZ
0.01% to 0.02%
10 mV to 120 V AC
10 mV to 100 VDC
0.5%
0.3%
40 Hz to 250 MHz
2.7%
Using Electrical Power Standard
Master / FLUKE with Current
Coil 6100A/ 6105A by Direct
Method
Using Universal Calibration
System Wavetek 9100 / FLUKE
5500 by Direct Method
Using Universal Calibration
System Wavetek 9100 by Direct
Method
Bibin Philip
Convenor
Laboratory
Electrical Research and Development Association, ERDA Road, GIDC,
Makarpura, Vadodara, Gujarat
Accreditation Standard
ISO/IEC 17025: 2005
Discipline
Certificate Number
Last Amended on
Electro-Technical Calibration
C-0062
14.07.2014
Quantity Measured/
Instrument
Time Base
Range / Frequency
Issue Date
Valid Until
Page
*Calibration Measurement
Capability ()
28.06.2014
27.06.2016
3 of 12
Remarks
4 nS to 5 S Time base
4% to 95% Duty Cycle
0.45%
0.15%
10 s to 90000 s
0.1% to 0.05%
Using Digital Time Interval
Meter, ADI Make by Direct
Method
8.
TIME
9.
CAPACITANCE
0.33 nF to 300 nF
300 nF to 30 F
30 F to 40 mF
1.86 % to 0.64%
0.64% to 0.93%
0.93% to 1.27%
Using Universal Calibration
System Wavetek 9100 / FLUKE
5500 by Direct Method
10.
DC POWER
100 mV to 1000V
100mA to 11 A
0.04% to 0.1%
Using FLUKE 5500 by Direct
Method
11.
AC ACTIVE POWER
1 , 50 Hz
0.25W to 14.375 W
14.375W to 24 kW
24kW to 575 kW
(50 V to 575 V,
0.5 A to 1000 A,
0.01lag to 0.01 lead)
0.05% to 0.24%
0.02%
0.05% to 0.42%
Using Electrical Power Standard
Master 6105A/6100A / FLUKE &
Auxiliaries with Current Coil,
Universal Calibration System,
9100 A, by Direct Method
12.
APPARENT POWER
1 , 50 Hz
0.25VA to 14.375VA
14.375VA 24 kVA
24kVA to 575 kVA
(50 V to 575 V,
0.5 A to 1000 A,
0.01lag to 0.01 lead)
0.11% to 0.05%
Using Electrical Power Standard
Master 6105A/6100A / FLUKE &
Auxiliaries with Current Coil,
Universal Calibration System,
9100 A, by Direct Method
13.
REACTIVE POWER
1 , 50 Hz
0.3VAr to 11.5 kVAr
21.6VAr to 11.5kVAr
10 V to 575 V,
0.05 A to 20 A,
0.01 lag to 0.01 lead
0.06 % to 0.12%
Using Electrical Power Standard
Master 6105A/6100A / FLUKE &
Auxiliaries with Current Coil,
Universal Calibration System,
9100 A, by Direct Method
14.
POWER FACTOR
1 , 50 Hz
0.01 lag to 0.01 lead
10 V to 575 V,
0.05% to 1.11%
Using Electrical Power Standard
Master/ FLUKE, Universal
Avijit Das
Program Manager
Bibin Philip
Convenor
Laboratory
Electrical Research and Development Association, ERDA Road, GIDC,
Makarpura, Vadodara, Gujarat
Accreditation Standard
ISO/IEC 17025: 2005
Discipline
Certificate Number
Last Amended on
Electro-Technical Calibration
C-0062
14.07.2014
Quantity Measured/
Instrument
Range / Frequency
Issue Date
Valid Until
Page
*Calibration Measurement
Capability ()
0.05 A to 1000 A
15.
16.
28.06.2014
27.06.2016
4 of 12
Remarks
Calibration System,9100A by
Direct Method
TEMPERATURE SIMULATION
(Indicator, Controller and Recorder )
Thermocouple Type
-100C to 1300C
0.3C
RTD Type
-200C to 800C
0.24C
HARMONICS OF
FUNDAMENTAL
FREQUENCY
1 to 25th order
(0 to 100 V)
1 to 25th order
(0 to 1A)
Using Universal Calibration
System Wavetek 9100 / FLUKE
5500
0.3%
Using Electrical Power Standard
Master / FLUKE by Direct
Method
MEASURE
1.
DC VOLTAGE$
1 mV to 1000 V
0.083% to 0.001%
Using 8 Digital Multimeter
Fluke 8508 by Direct /
Comparison Method
2.
DC CURRENT$
1 A to 20 mA
20 mA to 2 A
2 A to 20 A
0.065% to 0.002%
0.002% to 0.02%
0.02% to 0.044%
Using 8 Digital Multimeter
Fluke 8508 by Direct /
Comparison Method
3.
AC VOLTAGE$
10 Hz to 10 kHz
10 mV to 200 mV
200 mV to 200 V
0.07% to 0.013%
0.026% to 0.01%
Using 8 Digital Multimeter
Fluke 8508 by Direct /
Comparison Method
Avijit Das
Program Manager
40 Hz to 1 kHz
200 V to 1000 V
0.01% to 0.02%
10 kHz to 30 kHz
10 mV to 200 mV
0.013% to 0.1%
10 kHz to 100 kHz
200 mV to 200 V
0.04% to 0.082%
30 kHz to 100 kHz
10 mV to 200 mV
0.1% to 0.32%
Bibin Philip
Convenor
Laboratory
Electrical Research and Development Association, ERDA Road, GIDC,
Makarpura, Vadodara, Gujarat
Accreditation Standard
ISO/IEC 17025: 2005
Discipline
Certificate Number
Last Amended on
Electro-Technical Calibration
C-0062
14.07.2014
4.
Issue Date
Valid Until
Page
Quantity Measured/
Instrument
Range / Frequency
*Calibration Measurement
Capability ()
AC CURRENT$
50 Hz to 5 kHz
10 A to 200 mA
200 mA to 2 A
0.27% to 0.04%
0.04% to 0.11%
50 Hz to 1 kHz
2 A to 20 A
0.09% to 0.32%
28.06.2014
27.06.2016
5 of 12
Remarks
Using 8 Digital Multimeter
Fluke 8508 by Direct /
Comparison Method
5.
FREQUENCY$
10 Hz to 1 MHz
0.001%
Using 8 Digital Multimeter
Fluke 8508 by Direct /
Comparison Method
6.
RESISTANCE$
10 to 1
1 to 20 M
20 M to 200 M
200 M to 1 G
0.7% to 0.002%
0.002% to 0.004%
0.004% to 0.03%
0.03% to 0.60%
Using 8 Digital Multimeter
Fluke 8508, Fluke 9100A/
Multiproduct Calibrator 5500 &
Standard Resistor, Tettex 3200 A
by direct / Comparison Method
7.
DC POWER
0.075Wto20kW
(1.5 V to 1000 V,
0.05 A to 20 A)
0.2%
Using Digital Power Meter
Yokogawa, WT 3000 by Direct /
Comparison Method
8.
AC ACTIVE POWER
50 Hz
0.25Wto11.5kW
(10 V to 575 V,
0.05 A to 20 A,
Pf: 0.1 lag to UPF)
9.
10.
AC APPARENT
POWER
50 Hz
0.5VA to 11.5kVA
(10 V to 575 V,
0.05 A to 20 A
Pf : 0.8 lag to UPF)
REACTIVE POWER$
50 Hz
0.3VAr to 11.5kVAr
(10 V to 575 V,
Avijit Das
Program Manager
0.18%
Using Digital Power Meter
Yokogawa, WT 3000 by Direct
/ Comparison Method
0.14%
Using Digital Power Meter
Yokogawa, WT 3000 by Direct /
Comparison Method
0.7% to 0.24%
Using Digital Power Meter
Yokogawa, WT 3000 by Direct /
Comparison Method
Bibin Philip
Convenor
Laboratory
Electrical Research and Development Association, ERDA Road, GIDC,
Makarpura, Vadodara, Gujarat
Accreditation Standard
ISO/IEC 17025: 2005
Discipline
Certificate Number
Last Amended on
Electro-Technical Calibration
C-0062
14.07.2014
Quantity Measured/
Instrument
Range / Frequency
Issue Date
Valid Until
Page
*Calibration Measurement
Capability ()
28.06.2014
27.06.2016
6 of 12
Remarks
0.05 A to 20 A,
Pf: 0.05 lag to 0.05 lead )
11.
POWER FACTOR
12 .
0.05 lag to 0.1 lead
(10 V to 575 V,
0.05 A to 20 A)
0.4% to 0.2%
Using Digital Power Meter
Yokogawa, WT 3000 by Direct /
Comparison Method
TIME
1 ms to 10 ms
10 ms to 0.33 s
1%
1% to 0.1%
Using Digital Oscilloscope,
6 Digital Multimeter by Direct /
Comparison Method
13.
CAPACITANCE$
1 kHz
100 pF to 33 F
0.29% to 0.34%
Using Precision LCR Meter by
Direct Method
14.
TEMPERATURE SIMULATION$
(Indicator, Controller and Recorder)
Thermocouple Type
-100C to 1300C
0.05 C
Using 8 Digital Multimeter
Fluke 8508,Diigtal Precision
Thermometer, Cropico 3000
RTD Type
-200C to 800C
0.01C
0.3%
15.
HARMONICS OF
FUNDAMENTAL
FREQUENCY$
1 to 25th order
(0 to 100 V)
1 to 25th order
(0 to 1A)
16.
AC HIGH VOLTAGE$
50 Hz
1 kV to 150 kV
1.2%
1 kV to 100 kV
1.1%
Using 200 kV High Voltage
Divider by Comparison
Method
For LI
80 Vp to 1600 Vp
0.84 s to 60.0 s
Peak Magnitude
LI :0.72%
Front Time: 1.89%
Tail Time: 2.23 %
Using Reference Impulse
Calibrator & Digital
Oscilloscope by Standard
Comparison Method
17.
DC HIGH VOLTAGE$
18.
IMPULSE VOLTAGE/
MEASURING SYSTEM /
VOLTAGE DIVIDER$
Avijit Das
Program Manager
Using Digital Power Meter
Yokogawa, WT 3000 by
Direct Method
Using 200 kV AC/DC High
Voltage Divider by
Comparison Method
Bibin Philip
Convenor
Laboratory
Electrical Research and Development Association, ERDA Road, GIDC,
Makarpura, Vadodara, Gujarat
Accreditation Standard
ISO/IEC 17025: 2005
Discipline
Certificate Number
Last Amended on
Electro-Technical Calibration
C-0062
14.07.2014
Quantity Measured/
Instrument
19.
20.
21.
CAPACITANCE &
TAN $
CURRENT
TRANSFORMER$
RATIO ERROR
PHASE ANGLE ERROR
VOLTAGE
TRANSFORMER$
RATIO ERROR
PHASE ANGLE ERROR
Avijit Das
Program Manager
Range / Frequency
Issue Date
Valid Until
Page
*Calibration Measurement
Capability ()
For SI
100 Vp to 1600 Vp
20.0 s to 4000.0 s
SI : 0.66%
Front Time: 2.3%
Tail Time: 2.16 %
For Chopping
400 Vp to 1250 Vp
0.5 s
LIC: 1.12 %
Chopping Time: 2.57%
Peak Magnitude
0 to 300 kVp
Peak Magnitude
: 1.56 %
10 pF to 1000 pF &
1 x 10-5 to 3.5
100V to 100 kV
10 pF to 1000 pF &
1 x 10-5 to 3.5
100kV to 150 kV
5 to 3200/1A,
5A
28.06.2014
27.06.2016
7 of 12
Remarks
Using Capacitive Voltage
Divider
Using C & Tan Delta Bridge
by Standard comparison
Method
Cap: 0.1311%
Tan :
1.12 x 10-4
0.028% RE
Using C & Tan Delta Bridge
by Standard comparison
Method
Using STD CT
Make: Eltel by Standard
Comparison Method
0.91Min. PAE
220 - 330 - 440 - 550
- 660 - 880 -1100 /
110 V
0.059% RE
2.34Min PAE
2200 - 3300/110V
0.072% RE
1.440 Min PAE
5500 - 6600 11000/110V
5500 /3 - 6600/3 11000/3/110/3V
0.059% RE
2.337Min PAE
22000/110V
22000/3/110/3V
0.028% RE
0.0482Min PAE
Using STD PT
Using CTPT Bridge
by Standard Comparison
Method
Bibin Philip
Convenor
Laboratory
Electrical Research and Development Association, ERDA Road, GIDC,
Makarpura, Vadodara, Gujarat
Accreditation Standard
ISO/IEC 17025: 2005
Discipline
Certificate Number
Last Amended on
Electro-Technical Calibration
C-0062
14.07.2014
Quantity Measured/
Instrument
22.
RATIO / TURNS
METER$
RATIO ERROR
23.
24.
CT/PT TEST SET$
AC ENERGY$
(Single & Three Phase)
Active & Reactive Energy
50Hz
Active & Reactive Energy
45Hz to 55Hz (Except
Avijit Das
Program Manager
Range / Frequency
Issue Date
Valid Until
Page
*Calibration Measurement
Capability ()
33000/110V
33000/3/110/3V
0.028% RE
0.58Min PAE
66000/3/110/3V
From 80% to 120%
0.065% RE
2.34 Min PAE
132kV/3/110/3V
From 80% to 120%
0.065% RE
2.34 Min PAE
28.06.2014
27.06.2016
8 of 12
Remarks
Using CTPT Bridge
Using STD EPD
by Standard Comparison
Method
220 - 330 - 440 - 550 - 660 880 - 1100/110 V
2200 - 3300/110V
5500 - 6600 -11000/110V
22000/110V
33000/110V
66000/110V
0.072% RE
Using STD PT
by Standard Comparison
Method
CT MODE : 5A & 1A
0.008%RE
0.31Min PAE
Using STD CTPT TEST SET
by Standard Comparison
Method
PT MODE : 110&110/3V
0.005% RE
0.25MinPAE
Using Three Phase Reference
Standard Meter
10mAto120A, 55Vto290V,
UPF, 0.25lag to 0.25lead
10mAto120A, 55Vto290V
0.019%
ZERA
COM 3003
EPZto303to5
EPZto303to05to3
MTE
Bibin Philip
Convenor
Laboratory
Electrical Research and Development Association, ERDA Road, GIDC,
Makarpura, Vadodara, Gujarat
Accreditation Standard
ISO/IEC 17025: 2005
Discipline
Certificate Number
Last Amended on
Electro-Technical Calibration
C-0062
14.07.2014
Quantity Measured/
Instrument
50Hz)
Range / Frequency
Issue Date
Valid Until
Page
*Calibration Measurement
Capability ()
UPF, 0.25lag to 0.25lead
0.025%
28.06.2014
27.06.2016
9 of 12
Remarks
SRS 400.3 PRS 400.3
RADIAN RDto30to233
Active & Reactive Energy
45Hz to 55Hz
ACTARIS SM3050
Above 120A and Up to 200A,
55Vto288V
UPF, 0.25lag to 0.25lead
0.05%
by Standard comparison
Method
25.
DC VOLTAGE
10 mV to 1000 V
0.06% to 0.01%
Using 6 Digital Multimeter
Agilent 34401A by Direct /
Comparison Method
26.
DC CURRENT
10 mA to 20 A
0.06% to 0.2%
Using 6 Digital Multimeter
Agilent 34401A / Digital
Power meter WT 3000 by
Direct / Comparison Method
50 Hz
100 mV to 1000 V
0.13%
50 Hz
50 mA to 20 A AC
0.6% to 0.2%
27.
28.
AC VOLTAGE
AC CURRENT
Using 6 Digital Multimeter
Agilent 34401A / Digital
Power Meter WT 3000 by
Direct / Comparison Method
Using 6 Digital Multimeter
Agilent 34401A / Digital
Power Meter WT 3000 by
Direct / Comparison Method
29.
FREQUENCY
20 Hz to 300 kHz
0.05% to 0.013%
Using 6 Digital Multimeter
Agilent 34401A
30.
RESISTANCE
1m to 10
10 to 100 M
0.1% to 0.7%
0.1%
Using 6 Digital Multimeter
Agilent 34401A Fluke 9100A/
Multiproduct Calibrator 5500
& standard Resistor, by
Direct / Comparison Method
31.
AC APPARENT
POWER
50 Hz
0.5VA to 11.5kVA
(10 V to 575 V,
0.05 A to 20 A
Avijit Das
Program Manager
0.15%
Using Digital Power Meter
Yokogawa, WT 3000 by
Direct / Comparison Method
Bibin Philip
Convenor
Laboratory
Electrical Research and Development Association, ERDA Road, GIDC,
Makarpura, Vadodara, Gujarat
Accreditation Standard
ISO/IEC 17025: 2005
Discipline
Certificate Number
Last Amended on
Electro-Technical Calibration
C-0062
14.07.2014
Quantity Measured/
Instrument
Range / Frequency
Issue Date
Valid Until
Page
*Calibration Measurement
Capability ()
28.06.2014
27.06.2016
10 of 12
Remarks
Pf : 0.8 lag to UPF)
32.
CAPACITANCE
& TAN
10 pF to 1000 pF &
1 x 10-5 to 3.5
up to 12 kV
33.
VOLTAGE
TRANSFORMER
RATIO & PHASE
ANGLE ERROR
220 to 330 to 440 to 550
to 660 to 880 to
1100/110 V
34.
AC ENERGY
( & 3 )
Active & Reactive
Energy, 45Hz to 55Hz
2200 to 3300/110V
Cap: 0.071%
Tan : 3.84 x 10-5
C & Tan Bridge
Make: Tettex by Standard
comparison
Method
0.059% RE
2.34Min PAE
Using STD PT
Make: Pragati & Chandni,
Moonlight
Using CTPT Bridge
Make: Tettex
By Standard Comparison
Method
0.072% RE
2.33 Min PAE
5500 to 6600 to
11000/110V
5500/3to6600/3 to
11000/3/110/3V
0.065% RE
2.34Min PAE
22000/110V
22000/3/110/3V
0.039% RE
0.64Min PAE
33000/110V
33000/3/110/3V
0.040% RE
0.72Min PAE
10mA to 120A,
55V to 290V at UPF
0.043% @Active energy
0.040% @Reactive energy
10mA to 120A,
55V to 290V at 0.25 lag
0.066% @Active energy
0.063%@ Reactive energy
10mA to 120A,
55V to 290V at 0.25 lead
0.060% @Active energy
0.060%@ Reactive energy
Using Three Phase Reference
Standard Meter
MTE
PRS 400.3
RADIAN RDto30to233
ACTARIS
SM 3050
by Standard comparison
Method
Avijit Das
Program Manager
Bibin Philip
Convenor
Laboratory
Electrical Research and Development Association, ERDA Road, GIDC,
Makarpura, Vadodara, Gujarat
Accreditation Standard
ISO/IEC 17025: 2005
Discipline
Certificate Number
Last Amended on
Electro-Technical Calibration
C-0062
14.07.2014
Quantity Measured/
Instrument
Range / Frequency
Issue Date
Valid Until
Page
*Calibration Measurement
Capability ()
28.06.2014
27.06.2016
11 of 12
Remarks
MOBILE FACILITY
1.
CAPACITANCE
& TAN
2.
CURRENT
TRANSFORMER
RATIO ERROR
PHASE ANGLE ERROR
5 to 3200/1A,5A
VOLTAGE
TRANSFORMER
RATIO ERROR
PHASE ANGLE ERROR
220 - 330 - 440 - 550 660 - 880 -1100/110 V
0.059% RE
2.34Min PAE
2200 - 3300/110V
0.072% RE
2.33 Min PAE
5500 -6600 11000/110V 5500/3 6600/3 11000/3/110/3V
0.065% RE
2.34Min PAE
22000/110V
22000/3/110/3V
0.039% RE
0.64Min PAE
33000/110V
33000/3/110/3V
0.040% RE
0.72Min PAE
3.
4.
10 pF to 1000 pF&
1 x 10-5 to 1.0 upto
12 kV
Cap:0.70%
Tan : 7.01 x 10-5
0.037% RE
1.15Min PAE
AC ENERGY
(Single & Three Phase)
Active & Reactive
Energy, 45Hz to 55Hz
Avijit Das
Program Manager
Using Insulation Analyzer
by Standard comparison
Method
Using STD CT
STD CT
Using CTPT Bridge
by Standard Comparison
Method
Using STD PT
Using CTPT Bridge
Make: Tettex
by Standard Comparison
Method
Using Three Phase Reference
Standard Meter
MTE
PRS 400.3
10 mA to 120 A
55 V to 290V at UPF
0.043% @Active energy
0.040% @Reactive energy
10 mA to 120 A
55 V to 290 V at 0.25 lag
0.066% @Active energy
0.063% @Reactive energy
RADIAN
RDto30to233
ACTARIS
SM3050
Bibin Philip
Convenor
Laboratory
Electrical Research and Development Association, ERDA Road, GIDC,
Makarpura, Vadodara, Gujarat
Accreditation Standard
ISO/IEC 17025: 2005
Discipline
Certificate Number
Last Amended on
Electro-Technical Calibration
C-0062
14.07.2014
Quantity Measured/
Instrument
Range / Frequency
Issue Date
Valid Until
Page
*Calibration Measurement
Capability ()
28.06.2014
27.06.2016
12 of 12
Remarks
& Lead
by Standard comparison
Method
5.
VOLTAGE
50 V to 400 V
0.075%
6.
CURRENT
10 mA to 120 A
0.300%
7.
POWER FACTOR
UPF, 0.25lag to 0.25lead
0.250%
8.
FREQUENCY
45Hz to 55Hz
0.039%
* Measurement Capability is expressed as an uncertainty () at a confidence probability of 95%
$
Only in Permanent Laboratory
Only for Site Calibration
#
The laboratory is also capable for site calibration however, the uncertainty at site depends on the prevailing actual
environmental conditions and master equipment used.
Avijit Das
Program Manager
Bibin Philip
Convenor