Amacan S 60Hz
Amacan S 60Hz
Amacan S
60 Hz
Legal information/Copyright
Type Series Booklet Amacan S
All rights reserved. The contents provided herein must neither be distributed, copied, reproduced, edited or processed for any other purpose, nor otherwise transmitted, published or made available to a
third party without the manufacturer's express written consent.
Subject to technical modification without prior notice.
KSB Aktiengesellschaft, Frankenthal 27.09.2013
Contents
Contents
Water Applications: Water Transport .............................................................................................................. 4
Submersible Pump in Discharge Tube ........................................................................................................................... 4
Amacan S ................................................................................................................................................................... 4
Main applications ................................................................................................................................................ 4
Fluids handled ...................................................................................................................................................... 4
Operating data ....................................................................................................................................................4
Designation .......................................................................................................................................................... 4
Design details ....................................................................................................................................................... 4
Materials ..............................................................................................................................................................5
Coating/preservation ........................................................................................................................................... 5
Product features / customer benefits ................................................................................................................. 5
Acceptance tests / warranties .............................................................................................................................5
Design and selection information ...................................................................................................................... 5
Overview of product features / selection tables ................................................................................................ 6
Table of fluids handled .................................................................................................................................6
Overview of product features ....................................................................................................................... 7
Related documents .............................................................................................................................................. 7
Data to be indicated in the purchase order ....................................................................................................... 8
Material combinations ........................................................................................................................................9
Selection chart ...................................................................................................................................................10
Amacan S, n = 1180 / 880 / 710 / 590 rpm ................................................................................................... 10
Characteristic curves .......................................................................................................................................... 11
n = 1180 rpm ................................................................................................................................................ 11
n = 880 rpm .................................................................................................................................................. 15
n = 710 rpm .................................................................................................................................................. 21
n = 590 rpm .................................................................................................................................................. 23
Dimensions ......................................................................................................................................................... 24
UAG motors (650-364 to 800-505) [inch] ................................................................................................... 24
UTG motors (800-535 to 1300-820) [inch] ................................................................................................... 26
UAG motors (650-364 to 800-505) [mm] ..................................................................................................... 28
UTG motors (800-535 to 1300-820) [mm] ...................................................................................................30
Installation types ...............................................................................................................................................32
Scope of supply .................................................................................................................................................. 33
Accessories ......................................................................................................................................................... 34
Flow-straightening vane and intake chamber ........................................................................................... 34
Support rope and turnbuckle in the discharge tube ................................................................................. 36
Discharge tube cover with cable gland ......................................................................................................37
General assembly drawing ................................................................................................................................ 38
Designation
Example: Amacan S 1000-655 / 250 10 UT G2
Key to the designation
Code
Amacan
S
1000
655
250
10
Amacan S
UT
G2
Description
Type series
Impeller type, e.g. S = mixed flow impeller
Nominal diameter of the discharge tube [mm]
Nominal impeller diameter [mm]
Motor size
Number of motor poles
6
6-pole
8
8-pole
10
10-pole
12
12-pole
Motor version ( Page 7)
UA Without explosion protection, standard
(sizes 650-364 ... 800-505)
UT Without explosion protection, standard
(sizes 800-535 ... 1300-820)
Material variant ( Page 9)
G2 Gray cast iron, standard material variant
G3 Gray cast iron with Zn anodes, shaft
made of A 276 type 431 stainless steel
Design details
Design
Main applications
Irrigation and drainage pumping stations
Stormwater pumping stations
Raw and clean water pumps in water works
Cooling water pumps in power stations and in industry
Industrial water supply
Water pollution and flood control
Dock and sluice pumps
Drive
Three-phase asynchronous squirrel-cage motor
Aquaculture
Shaft seal
Fluids handled
Waste water
Leakage chamber
River water
Stormwater
Impeller type
Activated sludge
Seawater
Brackish water
Bearings
Grease-packed rolling element bearings
Operating data
Characteristic
Flow rate
Head
Motor rating
Temperature of fluid pumped1)
1)
Q
H
P2
t
Value
Up to 50,000 US gpm
[3000 l/s]
Up to 98 ft [30 m]
Up to 500 hp [370 kW]
Up to 104 F [40 C]
Amacan S
Material
Gray cast iron A48 Class 40 B
Gray cast iron A48 Class 40 B
Stainless steel
Duplex stainless steel
Stainless steel
Stainless steel
Coating/preservation
Surface treatment, primer and top coat
The operating point with the largest pump input power is decisive for the operating range of the motor. To compensate the
unavoidable tolerances of the characteristic curves of system,
pump and motor we recommend selecting a motor size which
provides sufficient power reserves.
Special coating
Available on request (extra charge and a longer delivery
period apply).
Acceptance tests
Acceptance tests to ISO/DIN or a comparable standard are
available against a surcharge.
Warranties
Quality is assured by means of an audited and certified
quality assurance system to DIN EN ISO 9001.
2)
[hp]
[kW]
Mains operation
< 40
> 40
< 30
> 30
10 %
5%
With frequency
inverter
15 %
10 %
Intake chamber
Determine the minimum water level t1min (diagram in general
arrangement drawing):
The minimum water level t1min is the water level required in the
pump's suction chamber to ensure the following:
The hydraulic system (propeller) is sufficiently submerged
(shown in diagram depending on pump size).
The pump does not draw in air-entraining vortices (shown
in diagram depending on flow rate).
The hydraulic system is free from cavitation (check against
the NPSHrequired value in the technical literature. The following conditions must be met:
NPSHavailable > NPSHrequired + safety allowance
NPSHavailable = 10.0 + (t1 - t3 - h7/2)
Safety allowance:
up to Qopt 1.65 ft [0.5 m]
larger than Qopt 3.3 ft [1.0 m]
Head (H)
The total pump head is composed as follows:
H = Hgeo + HV
Hgeo (static head)
Without discharge elbow Difference between suctionside water level and overflow edge
With discharge elbow Difference between suction-side
and discharge-side water level
HV (losses in the system)
Starting 1.65 ft [0.5 m] downstream of the pump: e.g. pipe
friction, elbow, swing check valve, etc.
If larger reserves are stipulated by local regulations or are required to compensate for uncertain factors in system calculations, these larger reserves must be provided.
Amacan S
Information, recommendations
Pre-screen with fine screen.
Pre-screen.
Max. dry substance 2 %
Material variant G3 up to
t = 77 F [25 C]5)
Coarse screen
650-364 / -365
650-404 / -405
800-505
800-535
850-550
900-600
900-615
900-620
1000-655
1300-820
3)
4)
5)
6)
[inch]
1 1/2
1 1/2
1 1/2
1 1/2
1 1/2
2
2
1 1/2
2 1/2
2 1/2
[mm]
40
40
40
40
40
50
50
40
60
60
Fine screen6)
[inch]
1
/2
1
/2
1
/2
1
/2
1
/2
1
1
1
/2
1
1
[mm]
15
15
15
15
15
25
25
15
25
25
Fluids to be pumped which are not listed in this table usually require higher-grade materials. Contact KSB.
Use of anodes required (efficiency reduced by 2 % to 3 %); anode to be checked every 6 to 12 months
For t > 25 C contact KSB (stainless steel variant).
Fine screens must be used for high pollution loads.
Amacan S
Motor version
UAG
6-pole
8-pole
10-pole
12-pole
Explosion protection
Version U...
Motor
Starting method
Voltage
Cooling
Power cable
Type
Length
Cable entry
Sealing elements
Elastomer seals
Shaft seal
Monitoring equipment
Winding temperature of the
motor
Bearing temperature
Leakage inside the motor
26 6 ... 120 6
75 8 ... 120 8
85 8 ... 160 8
60 10 ... 120 10
UTG
310 10
250 12 ... 370 12
Not explosion-proof
DOL, soft starter, frequency inverter
Related documents
General Arrangement Drawings 1589.396
7)
8)
9)
10)
11)
12)
13)
14)
S1BN8-F
rubber-sheathed cable
Standard
1000 V
EPR14)
194 F [90 C]
S07RC4N8-F
rubber-sheathed cable
Optional
750 V
EPR14)
194 F [90 C]
Amacan S
Amacan S
Description
G2
101
138
233
Pump casing
Bellmouth
Open counter-clockwise impeller
Closed counter-clockwise impeller16)
350/330
Bearing housing / bearing bracket
360
Bearing cover
412
O-ring
433
Mechanical seal
(pump end)
Mechanical seal
(drive end)
502
Casing wear ring
571
Bail
811
Motor housing
812
Motor housing cover
818
Shaft (rotor)
82-5
Adapter
834
Cable gland
Cable gland housing
Various
Screws/bolts
99-16
Anode
Other materials on request
G315)
(seawater variant)
A 48 Class 40 B
A 48 Class 30 B
A 890 CD 4 MCu
A 890 CD 4 MCu
A 48 Class 40 B
A 48 Class 30 B
NBR17) (FKM18))
SiC/SiC (bellows NBR17), Viton FPM18))
Carbon/SiC (bellows NBR17), Viton FPM18))
Stainless steel (A 276 Type 316)
A 536: 60-40-18/A 284 B19)
A 48 Class 40 B
A 48 Class 40 B
A 276 Type 420
A 276 Type 431
A 48 Class 40 B
A 48 Class 40 B
Stainless steel
Zn
Comparison of materials
EN
EN-GJL-200 (JL 1030)
EN-GJL-250 (JL 1040)
1.4517
1.4021
1.4057
NBR
FPM
EN-GJS-400-15 (JS 1030)
S235JR
ASTM
A 48 Class 30 B
A 48 Class 40 B
A 890 CD 4 MCu
A 276 Type 420
A 276 Type 431
NBR
FKM
A 536: 604018
A 284 B
Description of materials
Duplex stainless steel (1.4517 or technically equivalent material)
This type of cast steel is resistant to cavitation, has excellent
strength values and is used for high circumferential speeds. An
excellent resistance to pitting corrosion makes ferritic-austenitic stainless steel a popular choice for pumping acidic waste water with a high chloride content as well as seawater and brackish water. Thanks to its good chemical resistance, e.g. also
against waste water containing phosphorous and sulphuric
acid, this material is used in a wide range of applications in the
chemical industry and process engineering. Pumps made of duplex stainless steel have a very long service life, even when
handling brines, chemical waste water (pH 112), gray water
and landfill leachate.
15)
16)
17)
18)
19)
Pump set with cathodic protection (anodes to be checked every 6 to 12 months) and top coat of 0.0098 inch [250 m]
Size 900-620
Nitrile butadiene rubber (Perbunan)
FPM fluorocarbon rubber variant available as an option against a surcharge
A 535: 60-40-18 for motors 858 ... 1608.TG, 6010 ... 12010.TG; A 284 B for all other motors
Amacan S
1000
200
200
300
400
2000
4000
3000
Q [l/s]
500
10000
5000
2000
1000
20000
3000
4000
5000
50
40
B
...-720
8p
100
30
...-620 8p
A
A
...-600
8p
...-550
8p
50
40
...-404 6p
...-405 6p
...-810
10p
20
...-975 12p
...-615
...-655
10p
...-535
...-365 6p
8p
8p
10
A
...-820 12p
...-364 6p
20
...-725
10p
...-505
8p
30
...-550
10p
5
4
10
3
H [m]
H
[ft]
5
3000
4000
3000
10
Q [US.gpm]
5000
4000
5000
Standard range
Amacan S
20000
10000
Q [IM.gpm]
10000
30000
20000
40000
30000
50000
40000
100000 120000
50000
600
800
1000
1200
200
40
300
Q [l/s]
70
70
60
70
75
75
78
400
460
[%]
80
82
78
80
82
81.7
78
70
78
78
78
75
75
76.3
H [m
80
80
79.4
75
10
82.9
75
60
20
1600
Qmin
60
60
H [ft]
Q [m3/h] 1400
75
75
70
70
70
70
60
60
5
328
338
322
306
0
2600
28
3000
2200
4000
5000
3000
4000
Q [US.gpm] 6000
7000
Q [IM.gpm] 5000
NPSH3% [ft]
0
7400
6000
306
322
328 338
NPSH3% [m]
20
5
14
50
P [hp]
40
P [kW]
338
328
20
322
20
306
10
10
2600
3000
4000
5000
Q [US.gpm] 6000
7000
7400
K42980
Free passage
Rated power P2
650-364 / 26 6 UAG
650-364 / 30 6 UAG
650-364 / 50 6 UAG
20)
[hp]
[kW]
[kgm2]
33
45
63
25
35
47
0,67
0,67
0,68
These values are valid for a density = 1 kg/dm and a kinematic viscosity of up to 20 mm/s.
Amacan S
11
800
50
1000
220
1200
300
400
1800
2000
500
Q [l/s]
2100
580
Qmin
70
40
70
70
H [ft]
75
75
78
78
80
[%]
82
80
83.9
82
75
82.6
78
80
70
82
80.2
10
82
80
80
75
20
H [m]
78
77.2
80
75
75
75
78
78
75
70
70
70
363
70
352
346
329
0
3400
4000
3000
5000
4000
6000
5000
9000
Q [IM.gpm] 6000
7000
30
346
352
0
9400
7800
9
363
329
NPSH3% [ft]
NPSH3% [m]
20
5
16
80
50
P [hp]
50
363
P [kW]
352
346
329
10
3400
10
4000
5000
6000
9000
9400
K42981
Free passage
Rated power P2
650-365 / 30 6 UAG
650-365 / 50 6 UAG
650-365 / 65 6 UAG
21)
12
[hp]
45
63
80
[kW]
35
47
60
These values are valid for a density = 1 kg/dm and a kinematic viscosity of up to 20 mm/s.
Amacan S
[kgm2]
0,67
0,68
0,77
600
800
170
70
1000
200
250
60
75
300
1200
l/s
1400
350
1550
400
440
20
Qmin
75
H [ft]
Q [m3/h]
78
[%]
80
81.3
78
H [m]
80
75
40
80
80.6
78
80
78
79.8
78
75
78
75
10
380
75
362
346
20
2600
30
3000
2200
3500
4000
4500
3000
5000
4000
Q [US.gpm]
Q [IM.gpm]
6000
6500
7000
5000
5800
380
NPSH3% [ft]
20
8
NPSH3% [m]
362
346
10
80
P [hp]
380
P [kW]
60
40
362
40
30
2600
346
25
3000
3500
4000
4500
5000
Q [US.gpm]
6000
6500
7000
K42982
Free passage
Rated power P2
650-404 / 30 6 UAG
650-404 / 50 6 UAG
650-404 / 65 6 UAG
22)
[hp]
45
63
80
[kW]
35
47
60
[kgm2]
0,87
0,88
0,97
These values are valid for a density = 1 kg/dm and a kinematic viscosity of up to 20 mm/s.
Amacan S
13
1000
1500
300
400
80
75
70
80
75
80
60
75
70
40
Q [l/s]
80
75
20
84
82
84.4
84
83.7
82
80
80
82
81.6
H [m]
82
82
83.4
H [ft]
600
[%]
82
80
2000
500
Qmin
70
70
Q [m 3/h]
75
75
80
80
70
70
75
70
20
10
70
75
401
415
387
372
0
4000
5000
4000
Q [US.gpm]
7000
8000
9000
7000
8000
9000
20
401
387
50
415
372
NPSH 3%[ft]
0
11000
10000
NPSH 3%[m]
5
10
140
100
415
100
P [kW]
401
P [hp]
50
387
50
30
4000
372
5000
Q [US.gpm]
7000
8000
9000
10000
11000
K42983/1
Free passage
Rated power P2
650-405 / 50 6 UAG
650-405 / 65 6 UAG
650-405 / 80 6 UAG
650-405 / 100 6 UAG
650-405 / 120 6 UAG
23)
14
[hp]
63
80
100
125
145
[kW]
47
60
75
95
110
These values are valid for a density = 1 kg/dm and a kinematic viscosity of up to 20 mm/s.
Amacan S
[kgm2]
0,99
1,09
1,21
1,32
1,46
1200
75
1500
320
2000
400
75
70
70
70
75
75
40
80
80
75
H [ft]
600
Qmin
70
60
500
Q [m3/h]
80
82
82
80
84
84.8
82
82
82.4
Q [l/s]
700
840
20
H [m]
84
82
82
84
80
80
82
80
82
75
75
80
75
70
70
20
10
70
70
75
489
500
474
448
10
5000
50
NPSH3% [ft]
40
800
85.6
84
84.1
3000
[%]
84
84
2500
6000
4500
7000
8000
9000
6000
Q [US.gpm] 11000
8000
12000
Q [IM.gpm]
13000 13600
10000
11000
500
489
474
NPSH3% [m]
10
448
20
150
P [hp]
500
P [kW]
100
489
100
474
448
60
5000
6000
7000
8000
9000
Q [US.gpm] 11000
50
12000
13000 13600
K42984
Free passage
Rated power P2
800-505 / 75 8 UAG
800-505 / 100 8 UAG
800-505 / 120 8 UAG
24)
[hp]
100
135
165
[kW]
75
100
125
[kgm2]
3,03
3,34
3,56
These values are valid for a density = 1 kg/dm and a kinematic viscosity of up to 20 mm/s.
Amacan S
15
2000
3000
600
60
4000
1000
Q [l/s]
800
Qmin
70
75
70
75
70
40
Q [ m3 /h]
75
78
78
78
80
80
80
70
75
1200
1350
[%]
82
H [m]
84
82
85.7
84.1
84
82
84
83.3
H [ft]
4800
82
78
80
79.8
78
20
82
82
80
78
80
78
75
75
75
70
70
70
75
10
78
531
70
520
504
485
0
8000
36
NPSH3%[ft]
7000
10000
8000
12000
14000
16000
Q[US.gpm] 18000
10000
16000
485
30
0
22000
20000
504
18000
531
520
10
NPSH3%[m]
7
20
240
P [hp]
200
P [kW]
531
100
520
100
504
485
40
8000
10000
12000
14000
16000
40
Q[US.gpm] 18000
20000
22000
K42985
Free passage
Rated power P2
800-535 / 85 8 UTG
800-535 / 120 8 UTG
800-535 / 160 8 UTG
25)
16
[hp]
115
160
215
[kW]
85
120
160
These values are valid for a density = 1 kg/dm and a kinematic viscosity of up to 20 mm/s.
Amacan S
[kgm2]
3,3
3,3
3,9
1500
90
2000
2500
400
Q [m3/h]
600
70
80
Qmin
75
70
75
70
78
60
70
H [ft]
75
80
80
82
78
80
Q [l/s]
20
84
82
80
82
80
82
80
82
40
1100
84
84
80
82.2
1000
85.5
85.2
82
82
4000
[%]
84
82
84
75
3500
800
78
78
3000
80
78
H [m]
78
75
75
78
70
75
78
70
75
70
543
70
10
557
534
513
20
6000
5000
8000
6000
10000
12000 Q [US.gpm]14000
8000
10000
6
16000
Q [IM.gpm] 12000
18000
14000
NPSH3% [ft]
NPSH3% [m]
557
543
50
15
534
513
10
20
260
180
P [hp]
557
200
P [kW]
543
534
100
513
100
6000
8000
10000
16000
18000
K42986
Free passage
Rated power P2
26)
[hp]
160
215
275
[kW]
120
160
205
[kgm2]
4,7
5,3
9,9
These values are valid for a density = 1 kg/dm and a kinematic viscosity of up to 20 mm/s.
Amacan S
17
2000
3000
600
800
100
70
70
75
75
70
75
75
4000
1000
5000
Q [l/s]
1200
1400
Qmin
70
H [ft]
Q [m3/h]
80
80
80
50
[%]
84
84
84
82
84.1
H [m]
85.4
85
82
80
82
82
84
84
84
82
82
82.4
20
80
80
82
80
82
75
80
75
75
70
75
70
70
70
583
605
561
536
5
10
8000
70
NPSH3% [ft]
7000
10000
8000
12000
14000
10000
12000
14000
20000
16000
22000
18000
605
583
50
561
20
NPSH3% [m]
536
10
20
380
P [hp]
605
300
583
P [kW]
200
561
200
160
8000
536
120
10000
12000
14000
16000 Q [US.gpm]18000
20000
22000
K42988
Free passage
Rated power P2
27)
18
[hp]
275
335
390
[kW]
205
250
290
These values are valid for a density = 1 kg/dm and a kinematic viscosity of up to 20 mm/s.
Amacan S
[kgm2]
10,8
12,1
13,4
2000
3000
600
100
800
70
75
70
H [ft]
70
80
80
75
75
1000
Q [ m3/h]
Q [l/s]
82
80
82
1400
1600
H [m]
85.8
84
84.8
20
84
82
84
84
82
5800
[%]
84
82
80
5000
1200
Qmin
75
70
50
4000
82
82
82.8
75
75
80
82
80
80
80
70
70
75
75
70
615
588
70
567
545
0
8000
80
10000
12000
7000
14000
16000
10000
Q [US.gpm] 20000
15000
22000
Q [IM.gpm]
0
26000
24000
20000
615
NPSH3% [ft]
588
50
567
20
NPSH3% [m]
545
10
400
615
P [hp]
P [kW]
200
588
200
567
545
50
8000
50
10000
12000
14000
16000
Q [US.gpm] 20000
22000
24000
26000
K42989
Free passage
Rated power P2
28)
[hp]
275
335
390
[kW]
205
250
290
[kgm2]
11,1
12,4
13,7
These values are valid for a density = 1 kg/dm and a kinematic viscosity of up to 20 mm/s.
Amacan S
19
1000
140
1500
300
2000
Q [m3/h]
400
2500
600
Q [l/s]
70
70
100
70
75
75
70
75
75
78
78
78
78
3400
800
900
40
Qmin
H [ft]
3000
80
80
80
80
82
82
[%]
83.5
85
85.3
83.5
H [m]
85
83.5
84.2
82
83.5
82
83.9
82.8
83.5
82
80
82
83.5
80
82
82
80
80
75
610
75
78
75
78
75
50
78
78
70
20
585
562
70
540
30
4000
40
6000
4000
8000
6000
8000
14000
Q [IM.gpm] 10000
NPSH3% [ft]
15000
12000
540
562
585
NPSH3% [m]
10
610
20
4
10
340
P [hp]
300
610
P [kW]
200
585
562
200
540
120
4000
100
6000
8000
14000
15000
K42993
Free passage
Rated power P2
29)
20
[hp]
275
335
[kW]
205
250
These values are valid for a density = 1 kg/dm and a kinematic viscosity of up to 20 mm/s.
Amacan S
[kgm2]
14,1
15,4
1200
1500
2000
Q [m3/h]
400
2500
600
60
3000
Q [l/s]
800
900
Qmin
70
H [ft]
75
70
75
70
75
40
70
75
78
78
78
78
80
80
80
82
[%]
84
82
85.1
84.8
84
82
82
80
82
80
78
80
H [m]
84
84
83.6
81.8
82
80
80
75
70
70
70
513
5
5000
75
75
75
10
78
78
78
20
40
3200
534
70
557
543
2
6000
8000
4500
10000 Q [US.gpm]
6000
8000
Q [IM.gpm]
12000
14000
10000
12000
557
543
NPSH3% [ft]
NPSH3% [m]
10
534
513
20
10
140
100
P [hp]
557
100
P [kW]
543
534
60
5000
50
513
6000
10000 Q [US.gpm]
8000
12000
14000
K42987
Free passage
Rated power P2
850-550 / 60 10 UTG
850-550 / 90 10 UTG
850-550 / 120 10 UTG
30)
[hp]
75
120
160
[kW]
60
90
120
[kgm2]
4,5
4,9
5,2
These values are valid for a density = 1 kg/dm and a kinematic viscosity of up to 20 mm/s.
Amacan S
21
2400
80
3000
4000
700
5000
Q [m3/h] 6000
1000
7000
1500
Q [l/s]
7600
2000
Qmin
70
70
60
70
75
H [ft]
70
75
75
75
78
78 80
78
78
80
82
40
80
82
80
82
82
[%]
84
84
85.1
86
84
86.2
86
86.5
84
20
84
84
82
82
84
86
85.1
H [m]
84
86
80
78
20
82
82
80
78
80
80
78
75
10
704
75
689
70
75
78
675
70
656
0
10000
70
15000
10000
20000
15000
25000
20000
NPSH3% [ft]
50
0
34000
Q [US.gpm] 30000
Q [IM.gpm]
25000
689
656
28000
20
704
675
NPSH3% [m]
10
P [hp]
400
P [kW]
704
200
689
675
200
100
656
100
10000
15000
20000
25000
Q [US.gpm] 30000
34000
K42991
Free passage
Rated power P2
31)
22
[hp]
270
335
415
[kW]
200
250
310
These values are valid for a density = 1 kg/dm and a kinematic viscosity of up to 20 mm/s.
Amacan S
[kgm2]
15,7
17,8
23,8
5000
1300
6000
8000
1500
2000
60
70
75
40
H [ft]
70
78
75
70
75
10000
2500
Q [l/s]
12000
3000
3400
Qmin
75
70
Q [m3/h]
78
78
78
80
80
82
84
[%]
86
82
80
86
85
82
80.4
82
80
80
78
20
84
84
83.1
82
80
H [m]
86.9
84
78
82
80
78
75
80
75
75
70
75
10
78
70
70
70
818
794
776
755
0
20000
17000
40
25000
20000
30000
35000
25000
0
54000
50000
40000
776
44000
794 818
NPSH3% [m]
755
10
NPSH3% [ft]
20
550
400
P [hp]
P [kW]
400
818
794
200
100
20000
200
776
755
25000
30000
35000
50000
54000
K42992
Free passage
Rated power P2
32)
[hp]
250
335
430
500
[kW]
190
250
320
370
[kgm2]
24,7
30,6
33,3
36,0
These values are valid for a density = 1 kg/dm and a kinematic viscosity of up to 20 mm/s.
Amacan S
23
d5
l2
h1
d4
l1
h4
h2
d1
h3
d2
d3
33)
24
h1
h2
h3
h4
l1
l2
d1
d2
d3
d4
d5
[lbs]33)
82 1/4
82 1/4
82 1/4
82 1/4
82 1/4
82 1/4
82 7/8
82 7/8
82 7/8
82 7/8
82 7/8
90 3/4
90 3/4
90 3/4
94 1/2
99 1/4
99 1/4
80 3/4
80 3/4
80 3/4
80 3/4
80 3/4
80 3/4
81
81
81
81
81
88 7/8
88 7/8
88 7/8
92 2/8
97
97
10 1/4
10 1/4
10 1/4
10 1/4
10 1/4
10 1/4
11 3/8
11 3/8
11 3/8
11 3/8
11 3/8
11 3/8
11 3/8
11 3/8
14 5/8
14 5/8
14 5/8
63 1/4
63 1/4
63 1/4
63 1/4
63 1/4
63 1/4
63 3/4
63 3/4
63 3/4
63 3/4
633/4
71 5/8
71 5/8
71 5/8
75 3/8
80 1/8
80 1/8
25 5/8
25 5/8
25 5/8
25 5/8
25 5/8
25 5/8
26 1/8
26 1/8
26 1/8
26 1/8
26 1/8
26 1/8
26 1/8
26 1/8
31 1/4
31 1/4
31 1/4
2 3/4
2 3/4
2 3/4
2 3/4
2 3/4
2 3/4
2 3/4
2 3/4
2 3/4
2 3/4
2 3/4
2 3/4
2 3/4
2 3/4
3 1/2
3 1/2
3 1/2
24 5/8
24 5/8
24 5/8
24 5/8
24 5/8
24 5/8
24 7/16
24 7/16
24 7/16
24 7/16
24 7/16
24 7/16
24 7/16
24 7/16
30 1/2
30 1/2
30 1/2
19 11/16
19 11/16
19 11/16
19 11/16
19 11/16
19 11/16
21 1/4
21 1/4
21 1/4
21 1/4
21 1/4
21 1/4
21 1/4
21 1/4
26 3/16
26 3/16
26 3/16
20 1/16
20 1/16
20 1/16
20 1/16
20 1/16
20 1/16
19 11/16
19 11/16
19 11/16
19 11/16
19 11/16
19 11/16
19 11/16
19 11/16
25 1/4
25 1/4
25 1/4
15 3/8
15 3/8
15 3/8
15 3/8
15 3/8
15 3/8
15 3/8
15 3/8
15 3/8
15 3/8
15 3/8
15 3/8
15 3/8
15 3/8
18 3/4
18 3/4
18 3/4
1 3/8
1 3/8
1 3/8
1 3/8
1 3/8
1 3/8
1 3/8
1 3/8
1 3/8
1 3/8
1 3/8
1 3/8
1 3/8
1 3/8
1 3/4
1 3/4
1 3/4
2050
2072
2094
2039
2072
2138
2094
2116
2183
2072
2138
2425
2535
2673
3395
3660
3770
Complete pump set with 32.8 ft [10 m] power cable (460 V) and 16.4 ft [5 m] support rope
Amacan S
D
s1
h7
45
d7
d8 1)
d9
A
1)
Motor size
26
30
50
30
50
65
30
50
65
50
65
80
100
120
75
100
120
Number of
poles
6
6
6
6
6
6
6
6
6
6
6
6
6
6
8
8
8
d7
h7
d9
s1
26
26
26
26
26
26
26
26
26
26
26
26
26
26
32
32
32
20 7/8
20 7/8
20 7/8
20 7/8
20 7/8
20 7/8
20 7/8
20 7/8
20 7/8
20 7/8
20 7/8
20 7/8
20 7/8
20 7/8
26 3/4
26 3/4
26 3/4
8 7/8
8 7/8
8 7/8
8 7/8
8 7/8
8 7/8
10 7/16
10 7/16
10 7/16
10 7/16
10 7/16
10 7/16
10 7/16
10 7/16
13 3/16
13 3/16
13 3/16
35 7/16
35 7/16
35 7/16
35 7/16
35 7/16
35 7/16
35 7/16
35 7/16
35 7/16
35 7/16
35 7/16
35 7/16
35 7/16
35 7/16
41 3/8
41 3/8
41 3/8
/16
/16
5
/16
5
/16
5
/16
5
/16
5
/16
5
/16
5
/16
5
/16
5
/16
5
/16
5
/16
5
/16
5
/16
5
/16
5
/16
5
Amacan S
25
d5
l2
h1
d4
h2
d1
h4
X
45
d2
h3
l1
d3
34)
26
h1
h2
h3
h4
d1
d2
d3
d4
d5
l1
l2
[lbs]34)
107 7/8
107 7/8
107 7/8
109 7/16
109 7/16
125 9/16
109 7/16
109 7/16
109 7/16
123 13/16
123 13/16
123 13/16
122 13/16
122 13/16
122 13/16
122 1/4
122 1/4
127 3/8
127 3/8
145 1/16
129 1/8
140 15/16
149 13/16
149 13/16
106 5/16
106 5/16
106 5/16
107 7/8
107 7/8
123 1/4
107 7/8
107 7/8
107 7/8
121 7/16
121 7/16
121 7/16
120 1/2
120 1/2
120 1/2
119 7/8
119 7/8
125
125
142 1/8
126 3/4
138
146 7/8
146 7/8
13 3/4
13 3/4
13 3/4
16 5/16
16 5/16
16 5/16
16 5/16
16 5/16
16 5/16
17 11/16
17 11/16
17 11/16
11
17 /16
11
17 /16
11
17 /16
15 15/16
15 15/16
21 5/8
21 5/8
21 5/8
23 5/8
23 5/8
23 5/8
23 5/8
80 11/16
80 11/16
80 11/16
82 5/16
82 5/16
101 15/16
82 5/16
82 5/16
82 5/16
100 3/16
100 3/16
100 3/16
99 3/16
99 3/16
99 3/16
98 5/8
98 5/8
103 3/4
103 3/4
117 1/2
105 1/2
113 3/8
122 1/4
122 1/4
30 1/2
30 1/2
30 1/2
32 1/2
32 1/2
32 1/2
32 1/2
32 1/2
32 1/2
34 7/16
34 7/16
34 7/16
34 1/4
34 1/4
34 1/4
34 7/16
34 7/16
38 3/8
38 3/8
38 3/8
47 1/4
47 1/4
47 1/4
47 1/4
26 3/8
26 3/8
26 3/8
28 3/8
28 3/8
28 3/8
28 3/8
28 3/8
28 3/8
30 11/16
30 11/16
30 11/16
29 15/16
29 15/16
29 15/16
29 3/4
29 3/4
33 11/16
33 11/16
33 11/16
38 3/16
38 3/16
38 3/16
38 3/16
27 9/16
27 9/16
27 9/16
27 9/16
27 9/16
27 9/16
27 9/16
27 9/16
27 9/16
29 1/2
29 1/2
29 1/2
28 3/4
28 3/4
28 3/4
25 3/8
25 3/8
35 7/16
35 7/16
35 7/16
41 5/16
41 5/16
41 5/16
41 5/16
18 11/16
18 11/16
18 11/16
18 11/16
18 11/16
21 7/8
18 11/16
18 11/16
18 11/16
21 7/8
21 7/8
21 7/8
21 7/8
21 7/8
21 7/8
21 7/8
21 7/8
21 7/8
21 7/8
25 9/16
21 7/8
25 9/16
25 9/16
25 9/16
1 9/16
1 9/16
1 9/16
1 9/16
1 9/16
1 15/16
1 9/16
1 9/16
1 9/16
1 15/16
1 15/16
1 15/16
1 15/16
1 15/16
1 15/16
1 15/16
1 15/16
1 15/16
1 15/16
2 3/8
1 15/16
2 3/8
2 3/8
2 3/8
34 13/16
34 13/16
34 13/16
34 1/16
34 1/16
34 1/16
34 1/16
34 1/16
34 1/16
35 1/4
35 1/4
35 1/4
32 1/16
32 1/16
32 1/16
38 3/16
38 3/16
48 1/16
48 1/16
48 1/16
47 1/16
47 1/16
47 1/16
47 1/16
3 1/8
3 1/8
3 1/8
3 1/8
3 1/8
3 9/16
3 1/8
3 1/8
3 1/8
3 9/16
3 9/16
3 9/16
3 9/16
3 9/16
3 9/16
3 9/16
3 9/16
3 9/16
3 9/16
3 9/16
3 9/16
3 9/16
3 9/16
3 9/16
3726
3748
4056
3825
4145
5456
3682
3902
4045
5677
6030
6349
6129
6504
6812
5831
6217
6283
6757
8289
8686
10119
11001
11332
Complete pump set with 32.8 ft [10 m] power cable (460 V) and 16.4 ft [5 m] support rope
Amacan S
D
s1
h7
45
d7
d8 1)
d9
A
1)
Motor size
Number of poles
d7
d9
h7
s1
85
120
160
120
160
205
60
90
120
205
250
290
205
250
290
205
250
200
250
310
250
310
365
420
8
8
8
8
8
8
10
10
10
8
8
8
8
8
8
8
8
10
10
10
10
10
10
10
32
32
32
34 3/16
34 3/16
34 3/16
34 3/16
34 3/16
34 3/16
36
36
36
36
36
36
36
36
40
40
40
51 15/16
51 15/16
51 15/16
51 15/16
28 3/8
28 3/8
28 3/8
29 1/8
29 1/8
29 1/8
29 1/8
29 1/8
29 1/8
31 1/2
31 1/2
31 1/2
30 11/16
30 11/16
30 11/16
30 5/16
30 5/16
36 1/4
36 1/4
36 1/4
42 1/2
42 1/2
42 1/2
42 1/2
51 3/16
51 3/16
51 3/16
51 3/16
51 3/16
51 3/16
51 3/16
51 3/16
51 3/16
51 3/16
51 3/16
51 3/16
51 3/16
51 3/16
51 3/16
51 3/16
51 3/16
59 1/16
59 1/16
59 1/16
70 7/8
70 7/8
70 7/8
70 7/8
12 13/16
12 13/16
12 13/16
15 3/16
15 3/16
15 3/16
15 3/16
15 3/16
15 3/16
16 3/4
16 3/4
16 3/4
16 15/16
16 15/16
16 15/16
14 3/4
14 3/4
20 11/16
20 11/16
20 11/16
21 7/8
21 7/8
21 7/8
21 7/8
/16
/16
5
/16
5
/16
5
/16
5
/16
5
/16
5
/16
5
/16
3
/8
3
/8
3
/8
3
/8
3
/8
3
/8
3
/8
3
/8
3
/8
3
/8
3
/8
1
/2
1
/2
1
/2
1
/2
Amacan S
27
d5
l2
h1
d4
l1
h4
h2
d1
h3
d2
d3
Motor
size
650 - 364
650 - 364
650 - 364
650 - 365
650 - 365
650 - 365
650 - 404
650 - 404
650 - 404
650 - 405
650 - 405
650 - 405
650 - 405
650 - 405
800 - 505
800 - 505
800 - 505
35)
28
26
30
50
30
50
65
30
50
65
50
65
80
100
120
75
100
120
Number of
poles
6
6
6
6
6
6
6
6
6
6
6
6
6
6
8
8
8
h1
h2
h3
h4
l1
l2
d1
d2
d3
d4
d5
[kg]35)
2090
2090
2090
2090
2090
2090
2105
2105
2105
2105
2105
2305
2305
2305
2400
2520
2520
2042
2042
2042
2042
2042
2058
2058
2058
2058
2058
2258
2258
2258
2343
2463
2463
2463
260
260
260
260
260
260
290
290
290
290
290
290
290
290
370
370
370
1605
1605
1605
1605
1605
1605
1620
1620
1620
1620
1620
1820
1820
1820
1915
2035
2035
651
651
651
651
651
651
665
665
665
665
665
665
665
665
795
795
795
70
70
70
70
70
70
70
70
70
70
70
70
70
70
90
90
90
625
625
625
625
625
625
620
620
620
620
620
620
620
620
775
775
775
500
500
500
500
500
500
665
665
665
510
510
510
510
510
510
500
500
500
500
500
500
500
500
645
645
645
390
390
390
390
390
390
390
390
390
390
390
390
390
390
480
480
480
35
35
35
35
35
35
35
35
35
35
35
35
35
35
45
45
45
940
940
950
930
940
970
950
960
990
940
970
1100
1150
1190
1540
1660
1710
Complete pump set with 32.8 ft [10 m] power cable (460 V) and 16.4 ft [5 m] support rope
Amacan S
D
s1
h7
45
d7
d8 1)
d9
A
1)
Motor size
26
30
50
30
50
65
30
50
65
50
65
80
100
120
75
100
120
Number of
poles
6
6
6
6
6
6
6
6
6
6
6
6
6
6
8
8
8
d7
h7
d9
s1
660
660
660
660
660
660
660
660
660
660
660
660
660
660
813
813
813
530
530
530
530
530
530
530
530
530
530
530
530
530
530
680
680
680
225
225
225
225
225
225
265
265
265
265
265
265
265
265
335
335
335
900
900
900
900
900
900
900
900
900
900
900
900
900
900
1050
1050
1050
7,1
7,1
7,1
7,1
7,1
7,1
7,1
7,1
7,1
7,1
7,1
7,1
7,1
7,1
8
8
8
Amacan S
29
d5
l2
h1
d4
h2
d1
h4
X
45
d2
h3
l1
d3
Motor
size
800 - 535
800 - 535
800 - 535
850 - 550
850 - 550
850 - 550
850 - 550
850 - 550
850 - 550
900 - 600
900 - 600
900 - 600
900 - 615
900 - 615
900 - 615
900 - 620
900 - 620
1000 - 655
1000 - 655
1000 - 655
1300 - 820
1300 - 820
1300 - 820
1300 - 820
36)
30
85
120
160
120
160
205
60
90
120
205
250
290
205
250
290
205
250
200
250
310
190
250
320
370
Number of
poles
8
8
8
8
8
8
10
10
10
8
8
8
8
8
8
8
8
10
10
10
12
12
12
12
h1
h2
h3
h4
d1
d2
d3
d4
d5
l1
l2
[kg]36)
2740
2740
2740
2780
2780
3190
2780
2780
2780
3145
3145
3145
3120
3120
3120
3105
3105
3235
3235
3685
3280
3580
3805
3805
2700
2700
2700
2740
2740
3130
2740
2740
2740
3085
3085
3085
3060
3060
3060
3045
3045
3175
3175
3610
3220
3505
3730
3730
350
350
350
415
415
415
415
415
415
450
450
450
450
450
450
405
405
550
550
550
600
600
600
600
2050
2050
2050
2090
2090
2590
2090
2090
2090
2545
2545
2545
2520
2520
2520
2505
2505
2635
2635
2985
2680
2880
3105
3105
775
775
775
826
826
826
826
826
826
875
875
875
870
870
870
875
875
975
975
975
1200
1200
1200
1200
670
670
670
720
720
720
720
720
720
780
780
780
760
760
760
755
755
855
855
855
970
970
970
970
700
700
700
700
700
700
700
700
700
750
750
750
730
730
730
645
645
900
900
900
1050
1050
1050
1050
475
475
475
475
475
555
475
475
475
555
555
555
555
555
555
555
555
555
555
650
555
650
650
650
40
40
40
40
40
50
40
40
40
50
50
50
50
50
50
50
50
50
50
60
50
60
60
60
885
885
885
865
865
865
865
865
865
895
895
895
815
815
815
970
970
1220
1220
1220
1195
1195
1195
1195
80
80
80
80
80
90
80
80
80
90
90
90
90
90
90
90
90
90
90
90
90
90
90
90
1690
1700
1840
1735
1880
2475
1670
1770
1835
2575
2735
2880
2780
2950
3090
2645
2820
2850
3065
3760
3940
4590
4990
5140
Complete pump set with 32.8 ft [10 m] power cable (460 V) and 16.4 ft [5 m] support rope
Amacan S
D
s1
h7
45
d7
d8 1)
d9
A
1)
Motor size
85
120
160
120
160
205
60
90
120
205
250
290
205
250
290
205
250
200
250
310
190
250
320
370
Number of
poles
8
8
8
8
8
8
10
10
10
8
8
8
8
8
8
8
8
10
10
10
12
12
12
12
d7
d9
h7
s1
813
813
813
868
868
868
868
868
868
914
914
914
914
914
914
914
914
1016
1016
1016
1320
1320
1320
1320
720
720
720
740
740
740
740
740
740
800
800
800
780
780
780
770
770
920
920
920
1080
1080
1080
1080
1300
1300
1300
1300
1300
1300
1300
1300
1300
1300
1300
1300
1300
1300
1300
1300
1300
1500
1500
1500
1800
1800
1800
1800
325
325
325
375
375
375
375
375
375
415
415
415
420
420
420
365
365
515
515
515
545
545
545
545
8
8
8
8
8
8
8
8
8
10
10
10
10
10
10
10
10
10
10
10
12
12
12
12
Amacan S
31
Types of installation
BU discharge tube
Overflow design for installation in open intake chamber
BG discharge tube
Overflow design for installation in covered intake chamber with low suction-side water levels
CU discharge tube
Design with underfloor discharge for installation in open intake chamber
CG discharge tube
Design with underfloor discharge for installation in covered intake chamber with low
suction-side water levels
DU discharge tube
Design with above floor discharge nozzle for installation in open intake chamber
DG discharge tube
Design with above floor discharge nozzle for installation in covered intake chamber
with low suction-side water levels
37)
32
For information on the various designs (foundation measurements, intake chamber, etc.) refer to the general arrangement
drawings.
Amacan S
Amacan S
33
Bail
Anti-vortex vanes
Flow-straightening vane
34
Amacan S
Variant 2
Steel section
sR
hR
hR
s1
A
B
C
D
lR
A
B
C
D
(e1)
lR
(e1)
Amacan S
35
59-8
59-17.2
59-24
720
59-47*
A
59-7
59-17.1
*= The number of (intermediate) lifting rings depends on the lifting height of the lifting equipment and on the building structure. (Intermediate lifting rings are supplied as an option).
List of components
Part no.
59-8
59-17.2
59-47
59-24
720
59-17.1
Description
Turnbuckle
Shackle
(Intermediate) lifting ring(s)
Rope, low rotation design
Spacer
Shackle
59-7
Support spacer
36
Amacan S
Material
Stainless steel
Stainless steel
Stainless steel
Stainless steel
EPDM
Galvanized steel (stainless
steel optional)
GFRP
1
6
3
5
4
OW 380 091-00
List of components
Part no.
1
2
3
Description
Cable clamp (approximately every 400 mm)
Control cable
Power cable
Part no.
4
5
6
Description
Support rope 59-24
Spacer
Clamp cover
A
A
OW 380 836-00
List of components
Part No.
1
Description
Discharge tube cover
Part No.
4
2
3
Cover
Welding sleeve
5
6
Description
Threaded bush with cable entry to DIN 22419 with strain
relief and protection against kinking and twisting
Eyeplate for fastening the cable support (support rope)
Gasket, e.g. fabric-reinforced rubber
Amacan S
37
V
571
412
412
82-5
834
812
350
412
811
(80--1)
818
360
412
V
101
350
433
412
502
233
138
0W 383 890-00
List of components
Part No.
101
138
233
350
360
412
433
38
Description
Pump casing
Bellmouth
Open counter-clockwise impeller
Bearing housing
Bearing cover
O-ring
Mechanical seal
Amacan S
Part No.
502
571
811
812
82-5
818
834
Description
Casing wear ring
Bail
Motor housing
Motor housing cover
Adapter
Shaft (rotor)
Cable gland
V
412
834
812
571
82-5
412
330
811
(80--1)
233
502
138
818
Design:
closed impeller
412
360
V
350
101
350
433
412
502
233
138
UG 13169994
List of components
Part No.
101
138
233
330
350
360
412
Description
Pump casing
Bellmouth
Open counter-clockwise impeller
Closed counter-clockwise impeller
Bearing bracket
Bearing housing
Bearing cover
O-ring
Part No.
433
502
571
811
812
82-5
818
834
Description
Mechanical seal
Casing wear ring
Bail
Motor housing
Motor housing cover
Adapter
Shaft (rotor)
Cable gland
Amacan S
39
27.09.2013
1589.56/03-US
KSB, Inc.
4415 Sarellen Road Richmond, VA 23231
Phone: (804) 222-1818 Fax: (804) 226-6961 www.ksb-inc.com
KSB PUMPS Inc.
5885 Kennedy Road Mississauga Ontario L 4Z 2G3